Three-dimensional nano-biointerface as a new platform for guiding cell fate.
Liu, Xueli; Wang, Shutao
2014-04-21
Three-dimensional nano-biointerface has been emerging as an important topic for chemistry, nanotechnology, and life sciences in recent years. Understanding the exchanges of materials, signals, and energy at biological interfaces has inspired and helped the serial design of three-dimensional nano-biointerfaces. The intimate interactions between cells and nanostructures bring many novel properties, making three-dimensional nano-biointerfaces a powerful platform to guide cell fate in a controllable and accurate way. These advantages and capabilities endow three-dimensional nano-biointerfaces with an indispensable role in developing advanced biological science and technology. This tutorial review is mainly focused on the recent progress of three-dimensional nano-biointerfaces and highlights the new explorations and unique phenomena of three-dimensional nano-biointerfaces for cell-related fundamental studies and biomedical applications. Some basic bio-inspired principles for the design and creation of three-dimensional nano-biointerfaces are also delivered in this review. Current and further challenges of three-dimensional nano-biointerfaces are finally addressed and proposed.
Yang, Hui; Yuan, Bin; Zhang, Xi; Scherman, Oren A
2014-07-15
CONSPECTUS: Host-guest chemistry can greatly improve the selectivity of biomolecule-ligand binding on account of recognition-directed interactions. In addition, functional structures and the actuation of supramolecular assemblies in molecular systems can be controlled efficiently through various host-guest chemistry. Together, these highly selective, strong yet dynamic interactions can be exploited as an alternative methodology for applications in the field of programmable and controllable engineering of supramolecular soft materials through the reversible binding between complementary components. Many processes in living systems such as biotransformation, transportation of matter, and energy transduction begin with interfacial molecular recognition, which is greatly influenced by various external stimuli at biointerfaces. Detailed investigations about the molecular recognition at interfaces can result in a better understanding of life science, and further guide us in developing new biomaterials and medicines. In order to mimic complicated molecular-recognition systems observed in nature that adapt to changes in their environment, combining host-guest chemistry and surface science is critical for fabricating the next generation of multifunctional biointerfaces with efficient stimuli-responsiveness and good biocompatibility. In this Account, we will summarize some recent progress on multifunctional stimuli-responsive biointerfaces and biosurfaces fabricated by cyclodextrin- or cucurbituril-based host-guest chemistry and highlight their potential applications including drug delivery, bioelectrocatalysis, and reversible adsorption and resistance of peptides, proteins, and cells. In addition, these biointerfaces and biosurfaces demonstrate efficient response toward various external stimuli, such as UV light, pH, redox chemistry, and competitive guests. All of these external stimuli can aid in mimicking the biological stimuli evident in complex biological environments. We begin by reviewing the current state of stimuli-responsive supramolecular assemblies formed by host-guest interactions, discussing how to transfer host-guest chemistry from solution onto surfaces required for fabricating multifunctional biosurfaces and biointerfaces. Then, we present different stimuli-responsive biosurfaces and biointerfaces, which have been prepared through a combination of cyclodextrin- or cucurbituril-based host-guest chemistry and various surface technologies such as self-assembled monolayers or layer-by-layer assembly. Moreover, we discuss the applications of these biointerfaces and biosurfaces in the fields of drug release, reversible adsorption and release of some organic molecules, peptides, proteins, and cells, and photoswitchable bioelectrocatalysis. In addition, we summarize the merits and current limitations of these methods for fabricating multifunctional stimuli-responsive biointerfaces in a dynamic noncovalent manner. Finally, we present possible strategies for future designs of stimuli-responsive multifunctional biointerfaces and biosurfaces by combining host-guest chemistry with surface science, which will lead to further critical development of supramolecular chemistry at interfaces.
Meng, Jingxin; Liu, Hongliang; Liu, Xueli; Yang, Gao; Zhang, Pengchao; Wang, Shutao; Jiang, Lei
2014-09-24
By mimicking certain biochemical and physical attributes of biological cells, bio-inspired particles have attracted great attention for potential biomedical applications based on cell-like biological functions. Inspired by leukocytes, hierarchical biointerfaces are designed and prepared based on specific molecules-modified leukocyte-inspired particles. These biointerfaces can efficiently recognize cancer cells from whole blood samples through the synergistic effect of molecular recognition and topographical interaction. Compared to flat, mono-micro or nano-biointerfaces, these micro/nano hierarchical biointerfaces are better able to promote specific recognition interactions, resulting in an enhanced cell-capture efficiency. It is anticipated that this study may provide promising guidance to develop new bio-inspired hierarchical biointerfaces for biomedical applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
CMC-modified cellulose biointerface for antibody conjugation.
Orelma, Hannes; Teerinen, Tuija; Johansson, Leena-Sisko; Holappa, Susanna; Laine, Janne
2012-04-09
In this Article, we present a new strategy for preparing an antihemoglobin biointerface on cellulose. The preparation method is based on functionalization of the cellulose surface by the irreversible adsorption of CMC, followed by covalent linking of antibodies to CMC. This would provide the means for affordable and stable cellulose-based biointerfaces for immunoassays. The preparation and characterization of the biointerface were studied on Langmuir-Schaefer cellulose model surfaces in real time using the quartz crystal microbalance with dissipation and surface plasmon resonance techniques. The stable attachment of antihemoglobin to adsorbed CMC was achieved, and a linear calibration of hemoglobin was obtained. CMC modification was also observed to prevent nonspecific protein adsorption. The antihemoglobin-CMC surface regenerated well, enabling repeated immunodetection cycles of hemoglobin on the same surface.
Graphene-like 2D nanomaterial-based biointerfaces for biosensing applications.
Zhu, Chengzhou; Du, Dan; Lin, Yuehe
2017-03-15
Due to their unique structures and multifunctionalities, two-dimensional (2D) nanomaterials have aroused increasing interest in the construction of the novel biointerfaces for biosensing applications. Efforts in constructing novel biointerfaces led to exploit the more versatile and tunable graphene-like 2D nanomaterials (e.g. graphitic carbon nitride, boron nitride, transition metal dichalcogenides, and transition metal oxides) with various structural and compositional characteristics. This review highlights recent efforts in the design of graphene-like 2D nanomaterials and their derived biointerfaces and exploitation of their research on fluorescent sensors and a series of electrochemical sensors, including amperometric, electrochemiluminescence, photoelectrochemical and field-effect transistor sensors. Finally, we discuss some critical challenges and future perspectives in this field. Copyright © 2016. Published by Elsevier B.V.
Asymmetrically Functionalized Graphene for Photodependent Diode Rectifying Behavior
2011-06-06
catalysts for oxygen reduction in fuel cells, high-performance electrodes in supercapacitors , batteries, actuators, and sen- sors.[1,2] Of particular...Stoller et al.[1j] produced graphene-based supercapacitors free from any conducting filler with a specific capacitance of 135 Fg1 in aqueous electrolytes...dimensionally compatible and electrically conduc- tive component, Guo et al.[2g,h] further constructed a smart graphene-based multifunctional biointerface for
Martin, Teresa A.; Herman, Christine T.; Limpoco, Francis T.; Michael, Madeline C.; Potts, Gregory K.; Bailey, Ryan C.
2014-01-01
Methods for the generation of substrates presenting biomolecules in a spatially controlled manner are enabling tools for applications in biosensor systems, microarray technologies, fundamental biological studies and biointerface science. We have implemented a method to create biomolecular patterns by using light to control the direct covalent immobilization of biomolecules onto benzophenone-modified glass substrates. We have generated substrates presenting up to three different biomolecules patterned in sequence, and demonstrate biomolecular photopatterning on corrugated substrates. The chemistry of the underlying monolayer was optimized to incorporate poly(ethylene glycol) to enable adhesive cell adhesion onto patterned extracellular matrix proteins. Substrates were characterized with contact angle goniometry, AFM, and immunofluorescence microscopy. Importantly, radioimmunoassays were performed to quantify the site density of immobilized biomolecules on photopatterned substrates. Retention of function of photopatterned proteins was demonstrated both by native ligand recognition and cell adhesion to photopatterned substrates, revealing that substrates generated with this method are suitable for probing specific cell receptor-ligand interactions. This molecularly general photochemical patterning method is an enabling tool that will allow the creation of substrates presenting both biochemical and topographical variation, which is an important feature of many native biointerfaces. PMID:21793535
Phospholipid Polymer Biointerfaces for Lab-on-a-Chip Devices.
Xu, Yan; Takai, Madoka; Ishihara, Kazuhiko
2010-06-01
This review summarizes recent achievements and progress in the development of various functional 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer biointerfaces for lab-on-a-chip devices and applications. As phospholipid polymers, MPC polymers can form cell-membrane-like surfaces by surface chemistry and physics and thereby provide biointerfaces capable of suppressing protein adsorption and many subsequent biological responses. In order to enable application to microfluidic devices, a number of MPC polymers with diverse functions have been specially designed and synthesized by incorporating functional units such as charge and active ester for generating the microfluidic flow and conjugating biomolecules, respectively. Furthermore, these polymers were incorporated with silane or hydrophobic moiety to construct stable interfaces on various substrate materials such as glass, quartz, poly(methyl methacrylate), and poly(dimethylsiloxane), via a silane-coupling reaction or hydrophobic interactions. The basic interfacial properties of these interfaces have been characterized from multiple aspects of chemistry, physics, and biology, and the suppression of nonspecific bioadsorption and control of microfluidic flow have been successfully achieved using these biointerfaces on a chip. Further, many chip-based biomedical applications such as immunoassays and DNA separation have been accomplished by integrating these biointerfaces on a chip. Therefore, functional phospholipid polymer interfaces are promising and useful for application to lab-on-a-chip devices in biomedicine.
Optical regulation of protein adsorption and cell adhesion by photoresponsive GaN nanowires.
Li, Jingying; Han, Qiusen; Zhang, Ying; Zhang, Wei; Dong, Mingdong; Besenbacher, Flemming; Yang, Rong; Wang, Chen
2013-10-09
Interfacing nanowires with living cells is attracting more and more interest due to the potential applications, such as cell culture engineering and drug delivery. We report on the feasibility of using photoresponsive semiconductor gallium nitride (GaN) nanowires (NWs) for regulating the behaviors of biomolecules and cells at the nano/biointerface. The GaN NWs have been fabricated by a facile chemical vapor deposition method. The superhydrophobicity to superhydrophilicity transition of the NWs is achieved by UV illumination. Bovine serum albumin adsorption could be modulated by photoresponsive GaN NWs. Tunable cell detachment and adhesion are also observed. The mechanism of the NW surface responsible for modulating both of protein adsorption and cell adhesion is discussed. These observations of the modulation effects on protein adsorption and cell adhesion by GaN NWs could provide a novel approach toward the regulation of the behaviors of biomolecules and cells at the nano/biointerface, which may be of considerable importance in the development of high-performance semiconductor nanowire-based biomedical devices for cell culture engineering, bioseparation, and diagnostics.
Atomic force microscopy-based characterization and design of biointerfaces
NASA Astrophysics Data System (ADS)
Alsteens, David; Gaub, Hermann E.; Newton, Richard; Pfreundschuh, Moritz; Gerber, Christoph; Müller, Daniel J.
2017-03-01
Atomic force microscopy (AFM)-based methods have matured into a powerful nanoscopic platform, enabling the characterization of a wide range of biological and synthetic biointerfaces ranging from tissues, cells, membranes, proteins, nucleic acids and functional materials. Although the unprecedented signal-to-noise ratio of AFM enables the imaging of biological interfaces from the cellular to the molecular scale, AFM-based force spectroscopy allows their mechanical, chemical, conductive or electrostatic, and biological properties to be probed. The combination of AFM-based imaging and spectroscopy structurally maps these properties and allows their 3D manipulation with molecular precision. In this Review, we survey basic and advanced AFM-related approaches and evaluate their unique advantages and limitations in imaging, sensing, parameterizing and designing biointerfaces. It is anticipated that in the next decade these AFM-related techniques will have a profound influence on the way researchers view, characterize and construct biointerfaces, thereby helping to solve and address fundamental challenges that cannot be addressed with other techniques.
C-MEMS for bio-sensing applications
NASA Astrophysics Data System (ADS)
Song, Yin; Agrawal, Richa; Wang, Chunlei
2015-05-01
Developing highly sensitive, selective, and reproducible miniaturized bio-sensing platforms require reliable biointerface which should be compatible with microfabrication techniques. In this study, we have fabricated pyrolyzed carbon arrays with high surface area as a bio-sensing electrode, and developed the surface functionalization methods to increase biomolecules immobilization efficiency and further understand electrochemical phenomena at biointerfaces. The carbon microelectrode arrays with high aspect ratio have been fabricated by carbon microelectromechanical systems (C-MEMS) and nanomaterials such as graphene have been integrated to further increase surface area. To achieve the efficient covalent immobilization of biomolecules, various oxidation and reduction functionalization methods have been investigated. The oxidation treatment in this study includes vacuum ultraviolet, electrochemical activation, UV/Ozone and oxygen RIE. The reduction treatment includes direct amination and diazonium grafting. The developed bio-sensing platform was then applied for several applications, such as: DNA sensor; H2O2 sensor; aptamer sensor and HIV sensor.
Biointerfaces for Two-way Communication to Assess Hazards in the Aquatic Environment.
1999-11-01
to provide timely information on contaminants in freshwater and marine environments. 14. SUBJECT TERMS 15. NUMBER OF PAGES Sentinel species, aquatic ...for using aquatic organisms to provide timely information on contaminants in freshwater and marine environments. Some of the research challenges that...Technical Report 0001 Biointerfaces for Two-way Communication to Assess Hazards in the Aquatic Environment U.S. Army Center for Environmental Health
Roadmap on semiconductor-cell biointerfaces
NASA Astrophysics Data System (ADS)
Tian, Bozhi; Xu, Shuai; Rogers, John A.; Cestellos-Blanco, Stefano; Yang, Peidong; Carvalho-de-Souza, João L.; Bezanilla, Francisco; Liu, Jia; Bao, Zhenan; Hjort, Martin; Cao, Yuhong; Melosh, Nicholas; Lanzani, Guglielmo; Benfenati, Fabio; Galli, Giulia; Gygi, Francois; Kautz, Rylan; Gorodetsky, Alon A.; Kim, Samuel S.; Lu, Timothy K.; Anikeeva, Polina; Cifra, Michal; Krivosudský, Ondrej; Havelka, Daniel; Jiang, Yuanwen
2018-05-01
This roadmap outlines the role semiconductor-based materials play in understanding the complex biophysical dynamics at multiple length scales, as well as the design and implementation of next-generation electronic, optoelectronic, and mechanical devices for biointerfaces. The roadmap emphasizes the advantages of semiconductor building blocks in interfacing, monitoring, and manipulating the activity of biological components, and discusses the possibility of using active semiconductor-cell interfaces for discovering new signaling processes in the biological world.
An, Zhe; He, Jing
2011-10-28
The electronic transfer (eT) at bio-interfaces has been achieved by orientating 2D inorganic slabs in a regular arrangement with the slab ab-planes vertical to the electrode substrate. The eT rate is effectively promoted by tuning the nano-micro scale structures of perpendicular LDH arrays. This journal is © The Royal Society of Chemistry 2011
Qiu, Junlang; Chen, Guosheng; Liu, Shuqin; Zhang, Tianlang; Wu, Jiayi; Wang, Fuxin; Xu, Jianqiao; Liu, Yan; Zhu, Fang; Ouyang, Gangfeng
2016-06-07
A novel solid-phase microextraction (SPME) fiber was prepared by gluing poly(diallyldimethylammonium chloride) (PDDA) assembled graphene oxide (GO)-coated C18 composite particles (C18@GO@PDDA) onto a quartz fiber with polyaniline (PANI). The fiber surface coating was sequentially modified with bioinspired polynorepinephrine, which provided a smooth biointerface and makes the coating suitable for in vivo sampling. The novel custom-made coating was used to extract acidic pharmaceuticals, and high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) was employed for analysis. The custom-made coating exhibited a much higher extraction efficiency than the previously used commercial polydimethylsiloxane (PDMS) and polyacrylate (PA) coatings. The custom-made coating also possessed satisfactory stability (the relative standard deviations (RSDs) ranged from 1.60% to 10.3% for six sampling-desorption cycles), interfiber reproducibility (the RSDs ranged from 2.61% to 11.5%), and resistance to matrix effects. The custom-made fibers were used to monitor the presence of acid pharmaceuticals in dorsal-epaxial muscle of living fish, and satisfactory sensitivities (limits of detection ranged from 0.13 ng/g to 7.56 ng/g) were achieved. The accuracies were verified by the comparison with liquid extraction. Moreover, the novel fibers were successfully used to monitor the presence of acidic pharmaceuticals in living fish, which demonstrated that the custom-made fibers were feasible for possible long-term in vivo continuous pharmaceutical monitoring.
Nanoscale evaluation of lubricity on well-defined polymer brush surfaces using QCM-D and AFM.
Kitano, Kazuhiko; Inoue, Yuuki; Matsuno, Ryosuke; Takai, Madoka; Ishihara, Kazuhiko
2009-11-01
For preparing a "highly lubricated biointerface", which has both excellent lubricity and biocompatibility, we investigated the factors responsible for resistance to friction during polymer grafting. We prepared poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC), poly(2-hydroxyethyl methacrylate) (PHEMA), and poly(methyl methacrylate) (PMMA) brush layers with high graft density and well-controlled thickness using atom transfer radical polymerization (ATRP). We measured the water absorptivity in the polymer brush layers and the viscoelasticity of the polymer-hydrated layers using a quartz crystal microbalance with dissipation monitoring (QCM-D) measurements. The PMPC brush layer had the highest water absorptivity, while the PMPC-hydrated layer had the highest fluidity. The friction properties of the polymer brush layers were determined in air, water, and toluene by atomic force microscopy (AFM). The friction on each polymer brush decreased only when a good solvent was chosen for each polymer. In conclusion, the brush layer possessing high water absorptivity and fluidity in water contributes to reduce friction. PMPC grafting is an effective and promising method for obtaining highly lubricated biointerfaces.
Chiappini, Ciro; Martinez, Jonathan O.; De Rosa, Enrica; Almeida, Carina S.
2016-01-01
Nanoneedles display potential in mediating the delivery of drugs and biologicals, as well as intracellular sensing and single cell stimulation through direct access to the cell cytoplasm. Nanoneedles enable cytosolic delivery, negotiating the cell membrane and the endolysosomal system, thus overcoming these major obstacles to the efficacy of nanotherapeutics. The low toxicity and minimal invasiveness of nanoneedles has a potential for the sustained non-immunogenic delivery of payloads in vivo, provided that the development of biocompatible nanoneedles with a simple deployment strategy is achieved. Here we present a mesoporous silicon nanoneedle array that achieves a tight interface with the cell, rapidly negotiating local biological barriers to grant temporary access to the cytosol with minimal impact on cell viability. The tightness of this interfacing enables both delivery of cell-impermeant quantum dots in vivo and live intracellular sensing of pH. Dissecting the biointerface over time elucidated the dynamics of cell association and nanoneedle biodegradation, showing rapid interfacing leading to cytosolic payload delivery within less than 30 minutes in vitro. The rapid and simple application of nanoneedles in vivo to the surface of tissues with different architectures invariably resulted in the localized delivery of quantum dots to the superficial cells and their prolonged retention. This investigation provides an understanding of the dynamics of nanoneedles’ biointerface and delivery outlining a strategy for highly local intracellular delivery of nanoparticles and cell-impermeant payloads within live tissues. PMID:25858596
Plasma-Etching of Spray-Coated Single-Walled Carbon Nanotube Films for Biointerfaces
NASA Astrophysics Data System (ADS)
Kim, Joon Hyub; Lee, Jun-Yong; Min, Nam Ki
2012-08-01
We present an effective method for the batch fabrication of miniaturized single-walled carbon nanotube (SWCNT) film electrodes using oxygen plasma etching. We adopted the approach of spray-coating for good adhesion of the SWCNT film onto a pre-patterned Pt support and used O2 plasma patterning of the coated films to realize efficient biointerfaces between SWCNT surfaces and biomolecules. By these approaches, the SWCNT film can be easily integrated into miniaturized electrode systems. To demonstrate the effectiveness of plasma-etched SWCNT film electrodes as biointerfaces, Legionella antibody was selected as analysis model owing to its considerable importance to electrochemical biosensors and was detected using plasma-etched SWCNT film electrodes and a 3,3',5,5'-tetramethyl-benzidine dihydrochloride/horseradish peroxidase (TMB/HRP) catalytic system. The response currents increased with increasing concentration of Legionella antibody. This result indicates that antibodies were effectively immobilized on plasma-etched and activated SWCNT surfaces.
An, Zhe; Lu, Shan; Zhao, Liwei; He, Jing
2011-10-18
In this work, ordered vertical arrays of layered double hydroxide (LDH) nanosheets have been developed to achieve electron transfer (eT) at biointerfaces in electrochemical devices. It is found that tailoring the gap size of LDH nanosheet arrays could significantly promote the eT rate. This research has successfully extended nanomaterials for efficient modifications of electrode surfaces from nanoparticles, nanowires, nanorods, and nanotubes to nanosheets. © 2011 American Chemical Society
High-Performance Vertical Organic Electrochemical Transistors.
Donahue, Mary J; Williamson, Adam; Strakosas, Xenofon; Friedlein, Jacob T; McLeod, Robert R; Gleskova, Helena; Malliaras, George G
2018-02-01
Organic electrochemical transistors (OECTs) are promising transducers for biointerfacing due to their high transconductance, biocompatibility, and availability in a variety of form factors. Most OECTs reported to date, however, utilize rather large channels, limiting the transistor performance and resulting in a low transistor density. This is typically a consequence of limitations associated with traditional fabrication methods and with 2D substrates. Here, the fabrication and characterization of OECTs with vertically stacked contacts, which overcome these limitations, is reported. The resulting vertical transistors exhibit a reduced footprint, increased intrinsic transconductance of up to 57 mS, and a geometry-normalized transconductance of 814 S m -1 . The fabrication process is straightforward and compatible with sensitive organic materials, and allows exceptional control over the transistor channel length. This novel 3D fabrication method is particularly suited for applications where high density is needed, such as in implantable devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Xinyue; Deng, Jie; Ma, Lang; Cheng, Chong; Nie, Chuanxiong; He, Chao; Zhao, Changsheng
2014-12-16
In this study, we proposed a catechol chemistry inspired approach to construct surface self-cross-linked polymer nanolayers for the design of versatile biointerfaces. Several representative biofunctional polymers, P(SS-co-AA), P(SBMA-co-AA), P(EGMA-co-AA), P(VP-co-AA), and P(MTAC-co-AA), were first synthesized via reversible addition-fragmentation chain transfer (RAFT) polymerization, and then the catecholic molecules (dopamine, DA) were conjugated to the acrylic acid (AA) units by the facile carbodiimide chemistry. Then, the catechol (Cat) group conjugated biofunctional polymers, named PSS-Cat, PSBMA-Cat, PEGMA-Cat, PVP-Cat, and PMTAC-Cat, were applied for the construction of self-cross-linked nanolayers on polymeric substrates via the pH induced catechol cross-linking and immobilization. The XPS spectra, surface morphology, and wettability gave robust evidence that the catechol conjugated polymers were successfully coated, and the coated substrates possessed increased surface roughness and hydrophilicity. Furthermore, the systematic in vitro investigation of protein adsorption, platelet adhesion, activated partial thromboplastin time (APTT), thrombin time (TT), cell viability, and antibacterial ability confirmed that the coated nanolayers conferred the substrates with versatile biological performances. The PSS-Cat coated substrate had low blood component activation and excellent anticoagulant activity; while the PEGMA-Cat and PSBMA-Cat showed ideal resistance to protein fouling and inhibition of platelet activation. The PSS-Cat and PVP-Cat coated substrates exhibited promoted endothelial cell proliferation and viability. The PMTAC-Cat coated substrate showed an outstanding activity on bacterial inhibition. In conclusion, the catechol chemistry inspired approach allows the self-cross-linked nanolayers to be easily immobilized on polymeric substrates with the stable conformation and multiple biofunctionalities. It is expected that this low-cost and facile bioinspired coating system will present great potential in creating novel and versatile biointerfaces.
Microelectrodes with Three-Dimensional Structures for Improved Neural Interfacing
2001-10-25
highly xible bio-interfaces [2]. Polyimides combine excellent ectrical and mechanical characteristics with biocompatibility ], and are well known in...excellent biocompatibility , polyimide -based electrodes promise for fabrication of long-term implants for the use in prostheses. The flexible structures...R. R. Richardson, J. A. Miller, and W. M. Reichert, " Polyimides as Biomaterials - Preliminary Biocompatibility Testing," Biomaterials, vol. 14, pp
Biointerfacing polymeric microcapsules for in vivo near-infrared light-triggered drug release
NASA Astrophysics Data System (ADS)
Shao, Jingxin; Xuan, Mingjun; Si, Tieyan; Dai, Luru; He, Qiang
2015-11-01
Seeking safe and effective water-soluble drug carriers is of great significance in nanomedicine. To achieve this goal, we present a novel drug delivery system based on biointerfacing hollow polymeric microcapsules for effectively encapsulating water-soluble antitumor drug and gold nanorod (GNR) functionalization for triggered release of therapeutic drugs on-demand using low power near-infrared (NIR) radiation. The surface of polymeric microcapsules is covered with fluidic lipid bilayers to decrease the permeability of the wall of polymeric capsules. The temperature increase upon NIR illumination deconstructs the structure of the lipid membrane and polyelectrolyte multilayers, which in turn results in the rapid release of encapsulated water-soluble drug. In vivo antitumor tests demonstrate that this microcapsule has the effective ability of inhibiting tumor growth and preventing metastases. Real time in vivo fluorescence imaging results confirm that capsules can be excreted gradually from the animal body which in turn demonstrates the biocompatibility and biodegradation of these biointerfacing GNR-microcapsules. This intelligent system provides a novel anticancer platform with the advantages of controlled release, biological friendliness and credible biosafety.Seeking safe and effective water-soluble drug carriers is of great significance in nanomedicine. To achieve this goal, we present a novel drug delivery system based on biointerfacing hollow polymeric microcapsules for effectively encapsulating water-soluble antitumor drug and gold nanorod (GNR) functionalization for triggered release of therapeutic drugs on-demand using low power near-infrared (NIR) radiation. The surface of polymeric microcapsules is covered with fluidic lipid bilayers to decrease the permeability of the wall of polymeric capsules. The temperature increase upon NIR illumination deconstructs the structure of the lipid membrane and polyelectrolyte multilayers, which in turn results in the rapid release of encapsulated water-soluble drug. In vivo antitumor tests demonstrate that this microcapsule has the effective ability of inhibiting tumor growth and preventing metastases. Real time in vivo fluorescence imaging results confirm that capsules can be excreted gradually from the animal body which in turn demonstrates the biocompatibility and biodegradation of these biointerfacing GNR-microcapsules. This intelligent system provides a novel anticancer platform with the advantages of controlled release, biological friendliness and credible biosafety. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06350g
Wei, Yan; Mo, Xiaoju; Zhang, Pengchao; Li, Yingying; Liao, Jingwen; Li, Yongjun; Zhang, Jinxing; Ning, Chengyun; Wang, Shutao; Deng, Xuliang; Jiang, Lei
2017-06-27
Control of stem cell behaviors at solid biointerfaces is critical for stem-cell-based regeneration and generally achieved by engineering chemical composition, topography, and stiffness. However, the influence of dynamic stimuli at the nanoscale from solid biointerfaces on stem cell fate remains unclear. Herein, we show that electrochemical switching of a polypyrrole (Ppy) array between nanotubes and nanotips can alter surface adhesion, which can strongly influence mechanotransduction activation and guide differentiation of mesenchymal stem cells (MSCs). The Ppy array, prepared via template-free electrochemical polymerization, can be reversibly switched between highly adhesive hydrophobic nanotubes and poorly adhesive hydrophilic nanotips through an electrochemical oxidation/reduction process, resulting in dynamic attachment and detachment to MSCs at the nanoscale. Multicyclic attachment/detachment of the Ppy array to MSCs can activate intracellular mechanotransduction and osteogenic differentiation independent of surface stiffness and chemical induction. This smart surface, permitting transduction of nanoscaled dynamic physical inputs into biological outputs, provides an alternative to classical cell culture substrates for regulating stem cell fate commitment. This study represents a general strategy to explore nanoscaled interactions between stem cells and stimuli-responsive surfaces.
Lectin functionalized ZnO nanoarrays as a 3D nano-biointerface for bacterial detection.
Zheng, Laibao; Wan, Yi; Qi, Peng; Sun, Yan; Zhang, Dun; Yu, Liangmin
2017-05-15
The detection of pathogenic bacteria is essential in various fields, such as food safety, water environmental analysis, or clinical diagnosis. Although rapid and selective techniques have been achieved based on the fast and specific binding of recognitions elements and target, the sensitive detection of bacterial pathogens was limited by their low targets-binding efficiency. The three-dimensional (3D) nano-biointerface, compared with the two-dimensional (2D) flat substrate, has a much higher binding capacity, which can offer more reactive sites to bind with bacterial targets, resulting in a great improvement of detection sensitivity. Herein, a lectin functionalized ZnO nanorod (ZnO-NR) array has been fabricated and employed as a 3D nano-biointerface for Escherichia coli (E. coli) capture and detection by multivalent binding of concanavalin A (ConA) with polysaccharides on the cellular surface of E. coli. The 3D lectin functionalized ZnO-NR array-based assay shows reasonable detection limit and efficiently expanded linear range (1.0×10 3 to 1.0×10 7 cfumL -1 ) for pathogen detection. The platform has a potential for further applications and provides an excellent sensitivity approach for detection of pathogenic bacteria. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, He; Gu, Yue; Dong, Tao; Yan, Liuqing; Yan, Xiaoyi; Zhang, Tingting; Lu, Nannan; Xu, Zhiqian; Xu, Haixin; Zhang, Zhiquan; Bian, Ting
2018-06-30
The combination of nanoparticles and biomarkers yields functional nanostructured biointerface, which is playing a notable role in biotechnology development. Due to the 5-fold twined structure in the Au-Pt star-shaped decahedra not only allowed it to act as efficient scaffold for immobilization of antibody, but it also exhibits superior electrocatalytic activity toward H 2 O 2 reduction, the nanocrystal as the efficient signal transduction label is first employed to construct an electrochemical immunosensor. Donor-π-Acceptor (D-π-A) linking fashion generates a dipolar push-pull system and assures superior intramolecular charge transfer. It is considered as a suitable π-conjugated backbone for conducting polymer on biointerface application. Under a D-π-A architecture which imidazole as the π-bridge and amino phenyl/phenyl groups as peripheral electron-donating/withdrawing functional groups, 4-(2,4,5-triphenyl-1H-imidazol-1-yl) aniline (TPIDA) is designed and synthesized for good biocompatibility and high conductivity. In this proposal, we attempt to integrate the above-mentioned two features from nanobiotechnology and organic bioelectronics. Then, a novel nonenzymatic sandwich-type immunosensor is performed by Au-Pt core-shell with surface-engineered twinning as a label and π-conjugated D-π-A polymers as the signal amplification platform. Human IgG (HIgG) as the model target protein can be detected with a wide linear range from 0.1 pg mL -1 to 100 ng mL -1 . The detection limit is down to 0.06 pg mL -1 (S/N = 3). Moreover, as a practical application, the prepared biosensor is used to monitor HIgG level in human serum with desirable results obtained. Copyright © 2018 Elsevier B.V. All rights reserved.
76 FR 43335 - Center for Scientific Review Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
... Sciences & Technologies Integrated Review Group, Biomaterials and Biointerfaces Study Section. Date: August....gov . (Catalogue of Federal Domestic Assistance Program Nos. 93.306, Comparative Medicine; 93.333...
Involvement of Working Memory in College Students' Sequential Pattern Learning and Performance
ERIC Educational Resources Information Center
Kundey, Shannon M. A.; De Los Reyes, Andres; Rowan, James D.; Lee, Bern; Delise, Justin; Molina, Sabrina; Cogdill, Lindsay
2013-01-01
When learning highly organized sequential patterns of information, humans and nonhuman animals learn rules regarding the hierarchical structures of these sequences. In three experiments, we explored the role of working memory in college students' sequential pattern learning and performance in a computerized task involving a sequential…
Bioinspired Pollen-Like Hierarchical Surface for Efficient Recognition of Target Cancer Cells.
Wang, Wenshuo; Yang, Gao; Cui, Haijun; Meng, Jingxin; Wang, Shutao; Jiang, Lei
2017-08-01
The efficient recognition and isolation of rare cancer cells holds great promise for cancer diagnosis and prognosis. In nature, pollens exploit spiky structures to realize recognition and adhesion to stigma. Herein, a bioinspired pollen-like hierarchical surface is developed by replicating the assembly of pollen grains, and efficient and specific recognition to target cancer cells is achieved. The pollen-like surface is fabricated by combining filtering-assisted assembly and soft lithography-based replication of pollen grains of wild chrysanthemum. After modification with a capture agent specific to cancer cells, the pollen-like surface enables the capture of target cancer cells with high efficiency and specificity. In addition, the pollen-like surface not only assures high viability of captured cells but also performs well in cell mixture system and at low cell density. This study represents a good example of constructing cell recognition biointerfaces inspired by pollen-stigma adhesion. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Duval, Jérôme F L
2016-04-14
A mechanistic understanding of the processes governing metal toxicity to microorganisms (bacteria, algae) calls for an adequate formulation of metal partitioning at biointerfaces during cell exposure. This includes the account of metal transport dynamics from bulk solution to biomembrane and the kinetics of metal internalisation, both potentially controlling the intracellular and surface metal fractions that originate cell growth inhibition. A theoretical rationale is developed here for such coupled toxicodynamics and interfacial metal partitioning dynamics under non-complexing medium conditions with integration of the defining cell electrostatic properties. The formalism explicitly considers intertwined metal adsorption at the biointerface, intracellular metal excretion, cell growth and metal depletion from bulk solution. The theory is derived under relevant steady-state metal transport conditions on the basis of coupled Nernst-Planck equation and continuous logistic equation modified to include metal-induced cell growth inhibition and cell size changes. Computational examples are discussed to identify limitations of the classical Biotic Ligand Model (BLM) in evaluating metal toxicity over time. In particular, BLM is shown to severely underestimate metal toxicity depending on cell exposure time, metal internalisation kinetics, cell surface electrostatics and initial cell density. Analytical expressions are provided for the interfacial metal concentration profiles in the limit where cell-growth is completely inhibited. A rigorous relationship between time-dependent cell density and metal concentrations at the biosurface and in bulk solution is further provided, which unifies previous equations formulated by Best and Duval under constant cell density and cell size conditions. The theory is sufficiently flexible to adapt to toxicity scenarios with involved cell survival-death processes.
75 FR 22412 - Center for Scientific Review; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-28
...; Biomaterials and Biointerfaces Study Section. Date: May 25-26, 2010. Time: 8 a.m. to 5 p.m. Agenda: To review... Federal Domestic Assistance Program Nos. 93.306, Comparative Medicine; 93.333, Clinical Research, 93.306...
DC Plasma Synthesis of Vertically Aligned Carbon Nanofibers for Biointerfacing
NASA Astrophysics Data System (ADS)
Pearce, Ryan Christopher
Vertically aligned carbon nanofibers (VACNFs) are a class of materials whose nanoscale dimensions and physical properties makes them uniquely suitable as functional elements in many applications for biodetection and biointerfacing on a cellular level. Control of VACNF synthesis by catalytic plasma enhanced chemical vapor deposition (PECVD) presents many challenges in integration into devices and structures designed for biointerfacing, such as transparent or flexible substrates. This dissertation addresses ways to overcome many of these issues in addition to deepening the fundamental understanding of nano-synthesis in catalytic PECVD. First, a survey of the field of VACNF synthesis and biointerfacing is presented, identifying the present challenges and greatest experimental applications. It is followed by experimental observations that elucidate the underlying mechanism to fiber alignment during synthesis, a critical step for deterministic control of fiber growth. Using a grid of electrodes patterned by photolithography on an insulating substrate, it was found that the alignment of the fibers is controlled by the anisotropic etching provided by ions during dc-PECVD synthesis. The VACNFs that have been utilized for many cellular interfacing experiments have unique mechanical and fluorescent properties due to a SiNx coating. The mechanism for SiNx deposition to VACNF sidewalls during synthesis is explored in addition to a detailed study of the optical properties of the coating. To explain the optical properties of this coating it is proposed that the source of photoluminescence for the SiNx coated VACNFs is quantum confinement effects due to the presence of silicon nanoclusters embedded in a Si3N4 matrix. These luminescent fibers have proven useful as registry markers in cell impalefection studies. To realize VACNF arrays used as an inflatable angioplasty balloon with embedded fibers to deliver drugs across the blood-brain barrier, a method for transferring fibers to flexible polydimethylesiloxane (PDMS) is presented. A process has been developed that involves synthesizing fibers on aluminum, followed by spin coating a thin layer of PDMS and then dissolving the underlying aluminum with KOH. Finally, a method of fiber synthesis using just air and acetone as the process gases is presented, enabling the possibility of inatmosphere, large scale VACNF synthesis. It is envisioned that these advancements should assist the viability of large scale VACNF related technologies and will help to bridge the gap between experimental applications and industrial adoption.
Selective cell response on natural polymer bio-interfaces textured by femtosecond laser
NASA Astrophysics Data System (ADS)
Daskalova, A.; Trifonov, A.; Bliznakova, I.; Nathala, C.; Ajami, A.; Husinsky, W.; Declercq, H.; Buchvarov, I.
2018-02-01
This study reports on the evaluation of laser processed natural polymer-chitosan, which is under consideration as a biointerface used for temporary applications as skin and cartilage substitutes. It is employed for tissue engineering purposes, since it possesses a significant degree of biocompatibility and biodegradability. Chitosan-based thin films were processed by femtosecond laser radiation to enhance the surface properties of the material. Various geometry patterns were produced on polymer surfaces and employed to examine cellular adhesion and orientation. The topography of the modified zones was observed using scanning electron microscopy and confocal microscopy. Test of the material cytotoxicity was performed by evaluating the life/dead cell correlation. The obtained results showed that texturing with femtosecond laser pulses is appropriate method to initiate a predefined cellular response. Formation of surface modifications in the form of foams with an expansion of the material was created under laser irradiation with a number of applied laser pulses from N = 1-5. It is shown that irradiation with N > 5 results in disturbance of microfoam. Material characterization reveals a decrease in water contact angle values after laser irradiation of chitosan films. Consequently, changes in surface roughness of chitosan thin-film surface result in its functionalization. Cultivation of MC3T3 and ATMSC cells show cell orientational migration concerning different surface patterning. The influence of various pulse durations (varying from τ = 30-500 fs) over biofilms surface was examined regarding the evolution of surface morphology. The goal of this study was to define the optimal laser conditions (laser energy, number of applied pulses, and pulse duration) to alter surface wettability properties and porosity to improve material performance. The acquired set of results indicate the way to tune the surface properties to optimize cell-interface interaction.
77 FR 19675 - Center for Scientific Review; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-02
... Perspectives. Date: April 27, 2012. Time: 8 a.m. to 5 p.m. Agenda: To review and evaluate grant applications... Biointerfaces Study Section. Date: May 3-4, 2012. Time: 8 a.m. to 4 p.m. Agenda: To review and evaluate grant...
Multidisciplinary Graduate Curriculum on Integrative Biointerfacial Engineering
ERIC Educational Resources Information Center
Moghe, Prabhas V.; Roth, Charles M.
2006-01-01
A wide range of biotechnological and biomedical processes and products involves the design, synthesis, and analysis of biological interfaces. Such biointerfaces mediate interactions between living cells or intracellular species and designed materials or biologics. Incorporating the experiences of a NSF-sponsored IGERT (Integrative Graduate…
Somorjai, Gabor A; Frei, Heinz; Park, Jeong Y
2009-11-25
The challenge of chemistry in the 21st century is to achieve 100% selectivity of the desired product molecule in multipath reactions ("green chemistry") and develop renewable energy based processes. Surface chemistry and catalysis play key roles in this enterprise. Development of in situ surface techniques such as high-pressure scanning tunneling microscopy, sum frequency generation (SFG) vibrational spectroscopy, time-resolved Fourier transform infrared methods, and ambient pressure X-ray photoelectron spectroscopy enabled the rapid advancement of three fields: nanocatalysts, biointerfaces, and renewable energy conversion chemistry. In materials nanoscience, synthetic methods have been developed to produce monodisperse metal and oxide nanoparticles (NPs) in the 0.8-10 nm range with controlled shape, oxidation states, and composition; these NPs can be used as selective catalysts since chemical selectivity appears to be dependent on all of these experimental parameters. New spectroscopic and microscopic techniques have been developed that operate under reaction conditions and reveal the dynamic change of molecular structure of catalysts and adsorbed molecules as the reactions proceed with changes in reaction intermediates, catalyst composition, and oxidation states. SFG vibrational spectroscopy detects amino acids, peptides, and proteins adsorbed at hydrophobic and hydrophilic interfaces and monitors the change of surface structure and interactions with coadsorbed water. Exothermic reactions and photons generate hot electrons in metal NPs that may be utilized in chemical energy conversion. The photosplitting of water and carbon dioxide, an important research direction in renewable energy conversion, is discussed.
78 FR 67178 - Center for Scientific Review, Amended Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Center for Scientific Review, Amended Notice of Meeting Notice is hereby given of a change in the meeting of the Biomaterials and Biointerfaces Study Section, October 03, 2013, 08:00 a.m. to October 04, 2013, 04:00 p.m., Residence Inn...
A high speed sequential decoder
NASA Technical Reports Server (NTRS)
Lum, H., Jr.
1972-01-01
The performance and theory of operation for the High Speed Hard Decision Sequential Decoder are delineated. The decoder is a forward error correction system which is capable of accepting data from binary-phase-shift-keyed and quadriphase-shift-keyed modems at input data rates up to 30 megabits per second. Test results show that the decoder is capable of maintaining a composite error rate of 0.00001 at an input E sub b/N sub o of 5.6 db. This performance has been obtained with minimum circuit complexity.
Rational Design of Semiconductor Nanostructures for Functional Subcellular Interfaces.
Parameswaran, Ramya; Tian, Bozhi
2018-05-15
One of the fundamental questions guiding research in the biological sciences is how cellular systems process complex physical and environmental cues and communicate with each other across multiple length scales. Importantly, aberrant signal processing in these systems can lead to diseases that can have devastating impacts on human lives. Biophysical studies in the past several decades have demonstrated that cells can respond to not only biochemical cues but also mechanical and electrical ones. Thus, the development of new materials that can both sense and modulate all of these pathways is necessary. Semiconducting nanostructures are an emerging class of discovery platforms and tools that can push the limits of our ability to modulate and sense biological behaviors for both fundamental research and clinical applications. These materials are of particular interest for interfacing with cellular systems due to their matched dimension with subcellular components (e.g., cytoskeletal filaments), and easily tunable properties in the electrical, optical and mechanical regimes. Rational design via traditional or new approaches, such as nanocasting and mesoscale chemical lithography, can allow us to control micro- and nanoscale features in nanowires to achieve new biointerfaces. Both processes endogenous to the target cell and properties of the material surface dictate the character of these interfaces. In this Account, we focus on (1) approaches for the rational design of semiconducting nanowires that exhibit unique structures for biointerfaces, (2) recent fundamental discoveries that yield robust biointerfaces at the subcellular level, (3) intracellular electrical and mechanical sensing, and (4) modulation of cellular behaviors through material topography and remote physical stimuli. In the first section, we discuss new approaches for the synthetic control of micro- and nanoscale features of these materials. In the second section, we focus on achieving biointerfaces with these rationally designed materials either intra- or extracellularly. We last delve into the use of these materials in sensing mechanical forces and electrical signals in various cellular systems as well as in instructing cellular behaviors. Future research in this area may shift the paradigm in fundamental biophysical research and biomedical applications through (1) the design and synthesis of new semiconductor-based materials and devices that interact specifically with targeted cells, (2) the clarification of many developmental, physiological, and anatomical aspects of cellular communications, (3) an understanding of how signaling between cells regulates synaptic development (e.g., information like this would offer new insight into how the nervous system works and provide new targets for the treatment of neurological diseases), (4) and the creation of new cellular materials that have the potential to open up completely new areas of application, such as in hybrid information processing systems.
NASA Astrophysics Data System (ADS)
Xiong, Yuting; Jiang, Ge; Li, Minmin; Qing, Guangyan; Li, Xiuling; Liang, Xinmiao; Sun, Taolei
2017-01-01
Biological systems that utilize multiple weak non-covalent interactions and hierarchical assemblies to achieve various bio-functions bring much inspiration for the design of artificial biomaterials. However, it remains a big challenge to correlate underlying biomolecule interactions with macroscopic level of materials, for example, recognizing such weak interaction, further transforming it into regulating material’s macroscopic property and contributing to some new bio-applications. Here we designed a novel smart polymer based on polyacrylamide (PAM) grafted with lactose units (PAM-g-lactose0.11), and reported carbohydrate-carbohydrate interaction (CCI)-promoted macroscopic properties switching on this smart polymer surface. Detailed investigations indicated that the binding of sialic acid molecules with the grafted lactose units via the CCIs induced conformational transformation of the polymer chains, further resulted in remarkable and reversible switching in surface topography, wettability and stiffness. With these excellent recognition and response capacities towards sialic acid, the PAM-g-lactose0.11 further facilitated good selectivity, strong anti-interference and high adsorption capacity in the capture of sialylated glycopeptides (important biomarkers for cancers). This work provides some enlightenment for the development of biointerface materials with tunable property, as well as high-performance glycopeptide enrichment materials.
Parallelization of sequential Gaussian, indicator and direct simulation algorithms
NASA Astrophysics Data System (ADS)
Nunes, Ruben; Almeida, José A.
2010-08-01
Improving the performance and robustness of algorithms on new high-performance parallel computing architectures is a key issue in efficiently performing 2D and 3D studies with large amount of data. In geostatistics, sequential simulation algorithms are good candidates for parallelization. When compared with other computational applications in geosciences (such as fluid flow simulators), sequential simulation software is not extremely computationally intensive, but parallelization can make it more efficient and creates alternatives for its integration in inverse modelling approaches. This paper describes the implementation and benchmarking of a parallel version of the three classic sequential simulation algorithms: direct sequential simulation (DSS), sequential indicator simulation (SIS) and sequential Gaussian simulation (SGS). For this purpose, the source used was GSLIB, but the entire code was extensively modified to take into account the parallelization approach and was also rewritten in the C programming language. The paper also explains in detail the parallelization strategy and the main modifications. Regarding the integration of secondary information, the DSS algorithm is able to perform simple kriging with local means, kriging with an external drift and collocated cokriging with both local and global correlations. SIS includes a local correction of probabilities. Finally, a brief comparison is presented of simulation results using one, two and four processors. All performance tests were carried out on 2D soil data samples. The source code is completely open source and easy to read. It should be noted that the code is only fully compatible with Microsoft Visual C and should be adapted for other systems/compilers.
Fast-responding liquid crystal light-valve technology for color-sequential display applications
NASA Astrophysics Data System (ADS)
Janssen, Peter J.; Konovalov, Victor A.; Muravski, Anatoli A.; Yakovenko, Sergei Y.
1996-04-01
A color sequential projection system has some distinct advantages over conventional systems which make it uniquely suitable for consumer TV as well as high performance professional applications such as computer monitors and electronic cinema. A fast responding light-valve is, clearly, essential for a good performing system. Response speed of transmissive LC lightvalves has been marginal thus far for good color rendition. Recently, Sevchenko Institute has made some very fast reflective LC cells which were evaluated at Philips Labs. These devices showed sub millisecond-large signal-response times, even at room temperature, and produced good color in a projector emulation testbed. In our presentation we describe our highly efficient color sequential projector and demonstrate its operation on video tape. Next we discuss light-valve requirements and reflective light-valve test results.
Fibrin Association at Hybrid Biointerfaces Made of Clot-Binding Peptides and Polythiophene.
Puiggalí-Jou, A; Del Valle, Luis J; Armelin, Elaine; Alemán, Carlos
2016-10-01
The properties as biointerfaces of electroactive conducting polymer-peptide biocomposites formed by poly(3,4-ethylenedioxythiophene) (PEDOT) and CREKA or CR(NMe)EKA peptide sequences (where Glu has been replaced by N-methyl-Glu in the latter) have been compared. CREKA is a linear pentapeptide that recognizes clotted plasma proteins and selectively homes to tumors, while CR(NMe)EKA is an engineer to improve such properties by altering peptide-fibrin interactions. Differences between PEDOT-CREKA and PEDOT-CR(NMe)EKA reflect dissemblance in the organization of the peptides into the polymeric matrix. Both peptides affect fibrinogen thrombin-catalyzed polymerization causing the immediate formation of fibrin, whereas in the absence of thrombin this phenomenon is only observed for CR(NMe)EKA. Consistently, the fibrin-adsorption capacity is higher for PEDOT-CR(NMe)EKA than for PEDOT-CREKA, even though in both cases adsorbed fibrin exhibits round-like morphologies rather than the characteristic fibrous structure. PEDOT-peptide films coated with fibrin are selective in terms of cell adhesion, promoting the attachment of metastatic cells with respect to normal cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel
2017-01-01
Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Parallelization of NAS Benchmarks for Shared Memory Multiprocessors
NASA Technical Reports Server (NTRS)
Waheed, Abdul; Yan, Jerry C.; Saini, Subhash (Technical Monitor)
1998-01-01
This paper presents our experiences of parallelizing the sequential implementation of NAS benchmarks using compiler directives on SGI Origin2000 distributed shared memory (DSM) system. Porting existing applications to new high performance parallel and distributed computing platforms is a challenging task. Ideally, a user develops a sequential version of the application, leaving the task of porting to new generations of high performance computing systems to parallelization tools and compilers. Due to the simplicity of programming shared-memory multiprocessors, compiler developers have provided various facilities to allow the users to exploit parallelism. Native compilers on SGI Origin2000 support multiprocessing directives to allow users to exploit loop-level parallelism in their programs. Additionally, supporting tools can accomplish this process automatically and present the results of parallelization to the users. We experimented with these compiler directives and supporting tools by parallelizing sequential implementation of NAS benchmarks. Results reported in this paper indicate that with minimal effort, the performance gain is comparable with the hand-parallelized, carefully optimized, message-passing implementations of the same benchmarks.
NASA Astrophysics Data System (ADS)
Kyeyune-Nyombi, Eru; Morone, Flaviano; Liu, Wenwei; Li, Shuiqing; Gilchrist, M. Lane; Makse, Hernán A.
2018-01-01
Understanding the structural properties of random packings of jammed colloids requires an unprecedented high-resolution determination of the contact network providing mechanical stability to the packing. Here, we address the determination of the contact network by a novel strategy based on fluorophore signal exclusion of quantum dot nanoparticles from the contact points. We use fluorescence labeling schemes on particles inspired by biology and biointerface science in conjunction with fluorophore exclusion at the contact region. The method provides high-resolution contact network data that allows us to measure structural properties of the colloidal packing near marginal stability. We determine scaling laws of force distributions, soft modes, correlation functions, coordination number and free volume that define the universality class of jammed colloidal packings and can be compared with theoretical predictions. The contact detection method opens up further experimental testing at the interface of jamming and glass physics.
NASA Astrophysics Data System (ADS)
Tang, Zhenghua; Lim, Chang-Keun; Palafox-Hernandez, J. Pablo; Drew, Kurt L. M.; Li, Yue; Swihart, Mark T.; Prasad, Paras N.; Walsh, Tiffany R.; Knecht, Marc R.
2015-08-01
Bio-molecular non-covalent interactions provide a powerful platform for material-specific self-organization in aqueous media. Here, we introduce a strategy that integrates a synthetic optically-responsive motif with a materials-binding peptide to enable remote actuation. Specifically, we linked a photoswitchable azobenzene moiety to either terminus of a Au-binding peptide. We employed these hybrid molecules as capping agents for synthesis of Au nanoparticles. Integrated experiments and molecular simulations showed that the hybrid molecules maintained both of their functions, i.e. binding to Au and optically-triggered reconfiguration. The azobenzene unit was optically switched reversibly between trans and cis states while adsorbed on the particle surface. Upon switching, the conformation of the peptide component of the molecule also changed. This highlights the interplay between the surface adsorption and conformational switching that will be pivotal to the creation of actuatable nanoparticle bio-interfaces, and paves the way toward multifunctional peptide hybrids that can produce stimuli responsive nanoassemblies.Bio-molecular non-covalent interactions provide a powerful platform for material-specific self-organization in aqueous media. Here, we introduce a strategy that integrates a synthetic optically-responsive motif with a materials-binding peptide to enable remote actuation. Specifically, we linked a photoswitchable azobenzene moiety to either terminus of a Au-binding peptide. We employed these hybrid molecules as capping agents for synthesis of Au nanoparticles. Integrated experiments and molecular simulations showed that the hybrid molecules maintained both of their functions, i.e. binding to Au and optically-triggered reconfiguration. The azobenzene unit was optically switched reversibly between trans and cis states while adsorbed on the particle surface. Upon switching, the conformation of the peptide component of the molecule also changed. This highlights the interplay between the surface adsorption and conformational switching that will be pivotal to the creation of actuatable nanoparticle bio-interfaces, and paves the way toward multifunctional peptide hybrids that can produce stimuli responsive nanoassemblies. Electronic supplementary information (ESI) available: Additional modeling analysis, QCM analysis, UV-vis and CD spectroscopy data. See DOI: 10.1039/C5NR02311D
SPMBR: a scalable algorithm for mining sequential patterns based on bitmaps
NASA Astrophysics Data System (ADS)
Xu, Xiwei; Zhang, Changhai
2013-12-01
Now some sequential patterns mining algorithms generate too many candidate sequences, and increase the processing cost of support counting. Therefore, we present an effective and scalable algorithm called SPMBR (Sequential Patterns Mining based on Bitmap Representation) to solve the problem of mining the sequential patterns for large databases. Our method differs from previous related works of mining sequential patterns. The main difference is that the database of sequential patterns is represented by bitmaps, and a simplified bitmap structure is presented firstly. In this paper, First the algorithm generate candidate sequences by SE(Sequence Extension) and IE(Item Extension), and then obtain all frequent sequences by comparing the original bitmap and the extended item bitmap .This method could simplify the problem of mining the sequential patterns and avoid the high processing cost of support counting. Both theories and experiments indicate that the performance of SPMBR is predominant for large transaction databases, the required memory size for storing temporal data is much less during mining process, and all sequential patterns can be mined with feasibility.
Mechanical System Reliability and Cost Integration Using a Sequential Linear Approximation Method
NASA Technical Reports Server (NTRS)
Kowal, Michael T.
1997-01-01
The development of new products is dependent on product designs that incorporate high levels of reliability along with a design that meets predetermined levels of system cost. Additional constraints on the product include explicit and implicit performance requirements. Existing reliability and cost prediction methods result in no direct linkage between variables affecting these two dominant product attributes. A methodology to integrate reliability and cost estimates using a sequential linear approximation method is proposed. The sequential linear approximation method utilizes probability of failure sensitivities determined from probabilistic reliability methods as well a manufacturing cost sensitivities. The application of the sequential linear approximation method to a mechanical system is demonstrated.
PETER, BEATE; BUTTON, LE; STOEL-GAMMON, CAROL; CHAPMAN, KATHY; RASKIND, WENDY H.
2013-01-01
The purpose of this study was to evaluate a global deficit in sequential processing as candidate endophenotypein a family with familial childhood apraxia of speech (CAS). Of 10 adults and 13 children in a three-generational family with speech sound disorder (SSD) consistent with CAS, 3 adults and 6 children had past or present SSD diagnoses. Two preschoolers with unremediated CAS showed a high number of sequencing errors during single-word production. Performance on tasks with high sequential processing loads differentiated between the affected and unaffected family members, whereas there were no group differences in tasks with low processing loads. Adults with a history of SSD produced more sequencing errors during nonword and multisyllabic real word imitation, compared to those without such a history. Results are consistent with a global deficit in sequential processing that influences speech development as well as cognitive and linguistic processing. PMID:23339324
Kim, Sue Jin; Yun, Young Jun; Kim, Ki Woong; Chae, Changju; Jeong, Sunho; Kang, Yongku; Choi, Si-Young; Lee, Sun Sook; Choi, Sungho
2015-04-24
Hybrid nanostructures based on graphene and metal oxides hold great potential for use in high-performance electrode materials for next-generation lithium-ion batteries. Herein, a new strategy to fabricate sequentially stacked α-MnO2 /reduced graphene oxide composites driven by surface-charge-induced mutual electrostatic interactions is proposed. The resultant composite anode exhibits an excellent reversible charge/discharge capacity as high as 1100 mA h g(-1) without any traceable capacity fading, even after 100 cycles, which leads to a high rate capability electrode performance for lithium ion batteries. Thus, the proposed synthetic procedures guarantee a synergistic effect of multidimensional nanoscale media between one (metal oxide nanowire) and two dimensions (graphene sheet) for superior energy-storage electrodes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Online Sequential Projection Vector Machine with Adaptive Data Mean Update
Chen, Lin; Jia, Ji-Ting; Zhang, Qiong; Deng, Wan-Yu; Wei, Wei
2016-01-01
We propose a simple online learning algorithm especial for high-dimensional data. The algorithm is referred to as online sequential projection vector machine (OSPVM) which derives from projection vector machine and can learn from data in one-by-one or chunk-by-chunk mode. In OSPVM, data centering, dimension reduction, and neural network training are integrated seamlessly. In particular, the model parameters including (1) the projection vectors for dimension reduction, (2) the input weights, biases, and output weights, and (3) the number of hidden nodes can be updated simultaneously. Moreover, only one parameter, the number of hidden nodes, needs to be determined manually, and this makes it easy for use in real applications. Performance comparison was made on various high-dimensional classification problems for OSPVM against other fast online algorithms including budgeted stochastic gradient descent (BSGD) approach, adaptive multihyperplane machine (AMM), primal estimated subgradient solver (Pegasos), online sequential extreme learning machine (OSELM), and SVD + OSELM (feature selection based on SVD is performed before OSELM). The results obtained demonstrated the superior generalization performance and efficiency of the OSPVM. PMID:27143958
Online Sequential Projection Vector Machine with Adaptive Data Mean Update.
Chen, Lin; Jia, Ji-Ting; Zhang, Qiong; Deng, Wan-Yu; Wei, Wei
2016-01-01
We propose a simple online learning algorithm especial for high-dimensional data. The algorithm is referred to as online sequential projection vector machine (OSPVM) which derives from projection vector machine and can learn from data in one-by-one or chunk-by-chunk mode. In OSPVM, data centering, dimension reduction, and neural network training are integrated seamlessly. In particular, the model parameters including (1) the projection vectors for dimension reduction, (2) the input weights, biases, and output weights, and (3) the number of hidden nodes can be updated simultaneously. Moreover, only one parameter, the number of hidden nodes, needs to be determined manually, and this makes it easy for use in real applications. Performance comparison was made on various high-dimensional classification problems for OSPVM against other fast online algorithms including budgeted stochastic gradient descent (BSGD) approach, adaptive multihyperplane machine (AMM), primal estimated subgradient solver (Pegasos), online sequential extreme learning machine (OSELM), and SVD + OSELM (feature selection based on SVD is performed before OSELM). The results obtained demonstrated the superior generalization performance and efficiency of the OSPVM.
A high level language for a high performance computer
NASA Technical Reports Server (NTRS)
Perrott, R. H.
1978-01-01
The proposed computational aerodynamic facility will join the ranks of the supercomputers due to its architecture and increased execution speed. At present, the languages used to program these supercomputers have been modifications of programming languages which were designed many years ago for sequential machines. A new programming language should be developed based on the techniques which have proved valuable for sequential programming languages and incorporating the algorithmic techniques required for these supercomputers. The design objectives for such a language are outlined.
Bioinspired interface for nanobiodevices based on phospholipid polymer chemistry
Ishihara, Kazuhiko; Takai, Madoka
2009-01-01
This review paper describes novel biointerfaces for nanobiodevices. Biocompatible and non-biofouling surfaces are designed largely based on cell membrane structure, and the preparation and functioning of the bioinspired interface are evaluated and compared between living and artificial systems. A molecular assembly of polymers with a phospholipid polar group has been developed as the platform of the interface. At the surface, protein adsorption is effectively reduced and the subsequent bioreactions are suppressed. Through this platform, biomolecules with a high affinity to the specific molecules are introduced under mild conditions. The activity of the biomolecules is retained even after immobilization. This bioinspired interface is adapted to construct bionanodevices, that is, microfluidic chips and nanoparticles for capturing target molecules and cells. The interface functions well and has a very high efficiency for biorecognition. This bioinspired interface is a promising universal platform that integrates various fields of science and has useful applications. PMID:19324688
Mining of high utility-probability sequential patterns from uncertain databases
Zhang, Binbin; Fournier-Viger, Philippe; Li, Ting
2017-01-01
High-utility sequential pattern mining (HUSPM) has become an important issue in the field of data mining. Several HUSPM algorithms have been designed to mine high-utility sequential patterns (HUPSPs). They have been applied in several real-life situations such as for consumer behavior analysis and event detection in sensor networks. Nonetheless, most studies on HUSPM have focused on mining HUPSPs in precise data. But in real-life, uncertainty is an important factor as data is collected using various types of sensors that are more or less accurate. Hence, data collected in a real-life database can be annotated with existing probabilities. This paper presents a novel pattern mining framework called high utility-probability sequential pattern mining (HUPSPM) for mining high utility-probability sequential patterns (HUPSPs) in uncertain sequence databases. A baseline algorithm with three optional pruning strategies is presented to mine HUPSPs. Moroever, to speed up the mining process, a projection mechanism is designed to create a database projection for each processed sequence, which is smaller than the original database. Thus, the number of unpromising candidates can be greatly reduced, as well as the execution time for mining HUPSPs. Substantial experiments both on real-life and synthetic datasets show that the designed algorithm performs well in terms of runtime, number of candidates, memory usage, and scalability for different minimum utility and minimum probability thresholds. PMID:28742847
Manheimer, Eric D.; Peters, M. Robert; Wolff, Steven D.; Qureshi, Mehreen A.; Atluri, Prashanth; Pearson, Gregory D.N.; Einstein, Andrew J.
2011-01-01
Triple-rule-out computed tomography angiography (TRO CTA), performed to evaluate the coronary arteries, pulmonary arteries, and thoracic aorta, has been associated with high radiation exposure. Utilization of sequential scanning for coronary computed tomography angiography (CCTA) reduces radiation dose. The application of sequential scanning to TRO CTA is much less well defined. We analyzed radiation dose and image quality from TRO CTA performed in a single outpatient center, comparing scans from a period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n=35) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n=35). Sequential scanning was able to be employed in 86% of cases. The sequential-if-appropriate strategy, compared to the helical-only strategy, was associated with a 61.6% dose decrease (mean dose-length product [DLP] of 439 mGy×cm vs 1144 mGy×cm and mean effective dose of 7.5 mSv vs 19.4 mSv, respectively, p<0.0001). Similarly, there was a 71.5% dose reduction among 30 patients scanned with the sequential protocol compared to 40 patients scanned with the helical protocol under either strategy (326 mGy×cm vs 1141 mGy×cm and 5.5 mSv vs 19.4 mSv, respectively, p<0.0001). Although image quality did not differ between strategies, there was a non-statistically significant trend towards better quality in the sequential protocol compared to the helical protocol. In conclusion, approaching TRO CTA with a diagnostic strategy of sequential scanning as appropriate offers a marked reduction in radiation dose while maintaining image quality. PMID:21306693
Sequential Tests of Multiple Hypotheses Controlling Type I and II Familywise Error Rates
Bartroff, Jay; Song, Jinlin
2014-01-01
This paper addresses the following general scenario: A scientist wishes to perform a battery of experiments, each generating a sequential stream of data, to investigate some phenomenon. The scientist would like to control the overall error rate in order to draw statistically-valid conclusions from each experiment, while being as efficient as possible. The between-stream data may differ in distribution and dimension but also may be highly correlated, even duplicated exactly in some cases. Treating each experiment as a hypothesis test and adopting the familywise error rate (FWER) metric, we give a procedure that sequentially tests each hypothesis while controlling both the type I and II FWERs regardless of the between-stream correlation, and only requires arbitrary sequential test statistics that control the error rates for a given stream in isolation. The proposed procedure, which we call the sequential Holm procedure because of its inspiration from Holm’s (1979) seminal fixed-sample procedure, shows simultaneous savings in expected sample size and less conservative error control relative to fixed sample, sequential Bonferroni, and other recently proposed sequential procedures in a simulation study. PMID:25092948
Performance review using sequential sampling and a practice computer.
Difford, F
1988-06-01
The use of sequential sample analysis for repeated performance review is described with examples from several areas of practice. The value of a practice computer in providing a random sample from a complete population, evaluating the parameters of a sequential procedure, and producing a structured worksheet is discussed. It is suggested that sequential analysis has advantages over conventional sampling in the area of performance review in general practice.
Bechler, Shane L; Lynn, David M
2012-05-14
We report on conjugate addition-based approaches to the covalent layer-by-layer assembly of thin films and the post-fabrication functionalization of biointerfaces. Our approach is based on a recently reported approach to the "reactive" assembly of covalently cross-linked polymer multilayers driven by the 1,4-conjugate addition of amine functionality in poly(ethyleneimine) (PEI) to the acrylate groups in a small-molecule pentacrylate species (5-Ac). This process results in films containing degradable β-amino ester cross-links and residual acrylate and amine functionality that can be used as reactive handles for the subsequent immobilization of new functionality. Layer-by-layer growth of films fabricated on silicon substrates occurred in a supra-linear manner to yield films ≈ 750 nm thick after the deposition of 80 PEI/5-Ac layers. Characterization by atomic force microscopy (AFM) suggested a mechanism of growth that involves the reactive deposition of nanometer-scale aggregates of PEI and 5-Ac during assembly. Infrared (IR) spectroscopy studies revealed covalent assembly to occur by 1,4-conjugate addition without formation of amide functionality. Additional experiments demonstrated that acrylate-containing films could be postfunctionalized via conjugate addition reactions with small-molecule amines that influence important biointerfacial properties, including water contact angles and the ability of film-coated surfaces to prevent or promote the attachment of cells in vitro. For example, whereas conjugation of the hydrophobic molecule decylamine resulted in films that supported cell adhesion and growth, films treated with the carbohydrate-based motif D-glucamine resisted cell attachment and growth almost completely for up to 7 days in serum-containing media. We demonstrate that this conjugate addition-based approach also provides a means of immobilizing functionality through labile ester linkages that can be used to promote the long-term, surface-mediated release of conjugated species and promote gradual changes in interfacial properties upon incubation in physiological media (e.g., over a period of at least 1 month). These covalently cross-linked films are relatively stable in biological media for prolonged periods, but they begin to physically disintegrate after ≈ 30 days, suggesting opportunities to use this covalent layer-by-layer approach to design functional biointerfaces that ultimately erode or degrade to facilitate elimination.
Design and evaluation of a hybrid storage system in HEP environment
NASA Astrophysics Data System (ADS)
Xu, Qi; Cheng, Yaodong; Chen, Gang
2017-10-01
Nowadays, the High Energy Physics experiments produce a large amount of data. These data are stored in mass storage systems which need to balance the cost, performance and manageability. In this paper, a hybrid storage system including SSDs (Solid-state Drive) and HDDs (Hard Disk Drive) is designed to accelerate data analysis and maintain a low cost. The performance of accessing files is a decisive factor for the HEP computing system. A new deployment model of Hybrid Storage System in High Energy Physics is proposed which is proved to have higher I/O performance. The detailed evaluation methods and the evaluations about SSD/HDD ratio, and the size of the logic block are also given. In all evaluations, sequential-read, sequential-write, random-read and random-write are all tested to get the comprehensive results. The results show the Hybrid Storage System has good performance in some fields such as accessing big files in HEP.
Geada, Isidro Lorenzo; Ramezani-Dakhel, Hadi; Jamil, Tariq; Sulpizi, Marialore; Heinz, Hendrik
2018-02-19
Metallic nanostructures have become popular for applications in therapeutics, catalysts, imaging, and gene delivery. Molecular dynamics simulations are gaining influence to predict nanostructure assembly and performance; however, instantaneous polarization effects due to induced charges in the free electron gas are not routinely included. Here we present a simple, compatible, and accurate polarizable potential for gold that consists of a Lennard-Jones potential and a harmonically coupled core-shell charge pair for every metal atom. The model reproduces the classical image potential of adsorbed ions as well as surface, bulk, and aqueous interfacial properties in excellent agreement with experiment. Induced charges affect the adsorption of ions onto gold surfaces in the gas phase at a strength similar to chemical bonds while ions and charged peptides in solution are influenced at a strength similar to intermolecular bonds. The proposed model can be applied to complex gold interfaces, electrode processes, and extended to other metals.
Wang, Lingren; He, Min; Gong, Tao; Zhang, Xiang; Zhang, Lincai; Liu, Tao; Ye, Wei; Pan, Changjiang; Zhao, Changsheng
2017-11-21
It has been widely recognized that functional groups on biomaterial surfaces play important roles in blood compatibility. To construct an effective antithrombotic bio-interface onto the poly(ether sulfone) (PES) membrane surface, bio-functional groups of sodium carboxylic (-COONa), sodium sulfonic (-SO 3 Na) and amino (-NH 2 ) groups were introduced onto the PES membrane surface in three steps: the synthesis of PES with carboxylic (-COOH) groups (CPES) and water-soluble PES with sodium sulfonic (-SO 3 Na) groups and amino (-NH 2 ) groups (SNPES); the introduction of carboxylic groups onto the PES membrane by blending CPES with PES; and the grafting of SNPES onto CPES/PES membranes via the coupling of amino groups and carboxyl groups. The physical/chemical properties and bioactivities were dependent on the proportions of the additives. After introducing bio-functional groups, the excellent hemocompatibility of the modified membranes was confirmed by the inhibited platelet adhesion and activation, prolonged clotting times, suppressed blood-related complement and leukocyte-related complement receptor activations. Furthermore, cell tests indicated that the modified membranes showed better cytocompatibility in endothelial cell proliferation than the pristine PES membrane due to the synergistic promotion of the functional groups. To sum up, these results suggested that modified membranes present great potential in fields using blood-contacting materials, such as hemodialysis and surface endothelialization.
Wei, Ting; Zhan, Wenjun; Yu, Qian; Chen, Hong
2017-08-09
Smart biointerfaces with capability to regulate cell-surface interactions in response to external stimuli are of great interest for both fundamental research and practical applications. Smart surfaces with "ON/OFF" switchability for a single function such as cell attachment/detachment are well-known and useful, but the ability to switch between two different functions may be seen as the next level of "smart". In this work reported, a smart supramolecular surface capable of switching functions reversibly between bactericidal activity and bacteria-releasing ability in response to UV-visible light is developed. This platform is composed of surface-containing azobenzene (Azo) groups and a biocidal β-cyclodextrin derivative conjugated with seven quaternary ammonium salt groups (CD-QAS). The surface-immobilized Azo groups in trans form can specially incorporate CD-QAS to achieve a strongly bactericidal surface that kill more than 90% attached bacteria. On irradiation with UV light, the Azo groups switch to cis form, resulting in the dissociation of the Azo/CD-QAS inclusion complex and release of dead bacteria from the surface. After the kill-and-release cycle, the surface can be easily regenerated for reuse by irradiation with visible light and reincorporation of fresh CD-QAS. The use of supramolecular chemistry represents a promising approach to the realization of smart, multifunctional surfaces, and has the potential to be applied to diverse materials and devices in the biomedical field.
Biologically Derived Soft Conducting Hydrogels Using Heparin-Doped Polymer Networks
2015-01-01
The emergence of flexible and stretchable electronic components expands the range of applications of electronic devices. Flexible devices are ideally suited for electronic biointerfaces because of mechanically permissive structures that conform to curvilinear structures found in native tissue. Most electronic materials used in these applications exhibit elastic moduli on the order of 0.1–1 MPa. However, many electronically excitable tissues exhibit elasticities in the range of 1–10 kPa, several orders of magnitude smaller than existing components used in flexible devices. This work describes the use of biologically derived heparins as scaffold materials for fabricating networks with hybrid electronic/ionic conductivity and ultracompliant mechanical properties. Photo-cross-linkable heparin–methacrylate hydrogels serve as templates to control the microstructure and doping of in situ polymerized polyaniline structures. Macroscopic heparin-doped polyaniline hydrogel dual networks exhibit impedances as low as Z = 4.17 Ω at 1 kHz and storage moduli of G′ = 900 ± 100 Pa. The conductivity of heparin/polyaniline networks depends on the oxidation state and microstructure of secondary polyaniline networks. Furthermore, heparin/polyaniline networks support the attachment, proliferation, and differentiation of murine myoblasts without any surface treatments. Taken together, these results suggest that heparin/polyaniline hydrogel networks exhibit suitable physical properties as an electronically active biointerface material that can match the mechanical properties of soft tissues composed of excitable cells. PMID:24738911
Costa, Marilia G; Barbosa, José C; Yamamoto, Pedro T
2007-01-01
The sequential sampling is characterized by using samples of variable sizes, and has the advantage of reducing sampling time and costs if compared to fixed-size sampling. To introduce an adequate management for orthezia, sequential sampling plans were developed for orchards under low and high infestation. Data were collected in Matão, SP, in commercial stands of the orange variety 'Pêra Rio', at five, nine and 15 years of age. Twenty samplings were performed in the whole area of each stand by observing the presence or absence of scales on plants, being plots comprised of ten plants. After observing that in all of the three stands the scale population was distributed according to the contagious model, fitting the Negative Binomial Distribution in most samplings, two sequential sampling plans were constructed according to the Sequential Likelihood Ratio Test (SLRT). To construct these plans an economic threshold of 2% was adopted and the type I and II error probabilities were fixed in alpha = beta = 0.10. Results showed that the maximum numbers of samples expected to determine control need were 172 and 76 samples for stands with low and high infestation, respectively.
NASA Astrophysics Data System (ADS)
Dassekpo, Jean-Baptiste Mawulé; Zha, Xiaoxiong; Zhan, Jiapeng; Ning, Jiaqian
Geopolymer is an energy efficient and sustainable material that is currently used in construction industry as an alternative for Portland cement. As a new material, specific mix design method is essential and efforts have been made to develop a mix design procedure with the main focus on achieving better compressive strength and economy. In this paper, a sequential addition of synthesis parameters such as fly ash-sand, alkaline liquids, plasticizer and additional water at well-defined time intervals was investigated. A total of 4 mix procedures were used to study the compressive performance on fly ash-based geopolymer mortar and the results of each method were analyzed and discussed. Experimental results show that the sequential addition of sodium hydroxide (NaOH), sodium silicate (Na2SiO3), plasticizer (PL), followed by adding water (WA) increases considerably the compressive strengths of the geopolymer-based mortar. These results clearly demonstrate the high significant influence of sequential addition of synthesis parameters on geopolymer materials compressive properties, and also provide a new mixing method for the preparation of geopolymer paste, mortar and concrete.
Ashley, Kevin; Applegate, Gregory T; Marcy, A Dale; Drake, Pamela L; Pierce, Paul A; Carabin, Nathalie; Demange, Martine
2009-02-01
Because toxicities may differ for Cr(VI) compounds of varying solubility, some countries and organizations have promulgated different occupational exposure limits (OELs) for soluble and insoluble hexavalent chromium (Cr(VI)) compounds, and analytical methods are needed to determine these species in workplace air samples. To address this need, international standard methods ASTM D6832 and ISO 16740 have been published that describe sequential extraction techniques for soluble and insoluble Cr(VI) in samples collected from occupational settings. However, no published performance data were previously available for these Cr(VI) sequential extraction procedures. In this work, the sequential extraction methods outlined in the relevant international standards were investigated. The procedures tested involved the use of either deionized water or an ammonium sulfate/ammonium hydroxide buffer solution to target soluble Cr(VI) species. This was followed by extraction in a sodium carbonate/sodium hydroxide buffer solution to dissolve insoluble Cr(VI) compounds. Three-step sequential extraction with (1) water, (2) sulfate buffer and (3) carbonate buffer was also investigated. Sequential extractions were carried out on spiked samples of soluble, sparingly soluble and insoluble Cr(VI) compounds, and analyses were then generally carried out by using the diphenylcarbazide method. Similar experiments were performed on paint pigment samples and on airborne particulate filter samples collected from stainless steel welding. Potential interferences from soluble and insoluble Cr(III) compounds, as well as from Fe(II), were investigated. Interferences from Cr(III) species were generally absent, while the presence of Fe(II) resulted in low Cr(VI) recoveries. Two-step sequential extraction of spiked samples with (first) either water or sulfate buffer, and then carbonate buffer, yielded quantitative recoveries of soluble Cr(VI) and insoluble Cr(VI), respectively. Three-step sequential extraction gave excessively high recoveries of soluble Cr(VI), low recoveries of sparingly soluble Cr(VI), and quantitative recoveries of insoluble Cr(VI). Experiments on paint pigment samples using two-step extraction with water and carbonate buffer yielded varying percentages of relative fractions of soluble and insoluble Cr(VI). Sequential extractions of stainless steel welding fume air filter samples demonstrated the predominance of soluble Cr(VI) compounds in such samples. The performance data obtained in this work support the Cr(VI) sequential extraction procedures described in the international standards.
Wen, Qing; Wu, Ying; Zhao, Li-xin; Sun, Qian; Kong, Fan-ying
2010-02-01
A sequential anode-cathode double-chamber microbial fuel cell (MFC), in which the effluent of anode chamber was used as a continuous feed for an aerated cathode chamber, was constructed in this experiment to investigate the performance of brewery wastewater treatment in conjugation with electricity generation. Carbon fiber was used as anode and plain carbon felt with biofilm as cathode. When hydraulic retention time (HRT) was 14.7 h, a relatively high chemical oxygen demand (COD) removal efficiency of 91.7%-95.7% was achieved under long-term stable operation. The MFC displayed an open circuit voltage of 0.434 V and a maximum power density of 830 mW/m(3) at an external resistance of 300 Omega. To estimate the electrochemical performance of the MFC, electrochemical measurements were carried out and showed that polarization resistance of anode was the major limiting factor in the MFC. Since a high COD removal efficiency was achieved, we conclude that the sequential anode-cathode MFC constructed with bio-cathode in this experiment could provide a new approach for brewery wastewater treatment.
Wen, Qing; Wu, Ying; Zhao, Li-xin; Sun, Qian; Kong, Fan-ying
2010-01-01
A sequential anode-cathode double-chamber microbial fuel cell (MFC), in which the effluent of anode chamber was used as a continuous feed for an aerated cathode chamber, was constructed in this experiment to investigate the performance of brewery wastewater treatment in conjugation with electricity generation. Carbon fiber was used as anode and plain carbon felt with biofilm as cathode. When hydraulic retention time (HRT) was 14.7 h, a relatively high chemical oxygen demand (COD) removal efficiency of 91.7%–95.7% was achieved under long-term stable operation. The MFC displayed an open circuit voltage of 0.434 V and a maximum power density of 830 mW/m3 at an external resistance of 300 Ω. To estimate the electrochemical performance of the MFC, electrochemical measurements were carried out and showed that polarization resistance of anode was the major limiting factor in the MFC. Since a high COD removal efficiency was achieved, we conclude that the sequential anode-cathode MFC constructed with bio-cathode in this experiment could provide a new approach for brewery wastewater treatment. PMID:20104642
Effects of neostriatal 6-OHDA lesion on performance in a rat sequential reaction time task.
Domenger, D; Schwarting, R K W
2008-10-31
Work in humans and monkeys has provided evidence that the basal ganglia, and the neurotransmitter dopamine therein, play an important role for sequential learning and performance. Compared to primates, experimental work in rodents is rather sparse, largely due to the fact that tasks comparable to the human ones, especially serial reaction time tasks (SRTT), had been lacking until recently. We have developed a rat model of the SRTT, which allows to study neural correlates of sequential performance and motor sequence execution. Here, we report the effects of dopaminergic neostriatal lesions, performed using bilateral 6-hydroxydopamine injections, on performance of well-trained rats tested in our SRTT. Sequential behavior was measured in two ways: for one, the effects of small violations of otherwise well trained sequences were examined as a measure of attention and automation. Secondly, sequential versus random performance was compared as a measure of sequential learning. Neurochemically, the lesions led to sub-total dopamine depletions in the neostriatum, which ranged around 60% in the lateral, and around 40% in the medial neostriatum. These lesions led to a general instrumental impairment in terms of reduced speed (response latencies) and response rate, and these deficits were correlated with the degree of striatal dopamine loss. Furthermore, the violation test indicated that the lesion group conducted less automated responses. The comparison of random versus sequential responding showed that the lesion group did not retain its superior sequential performance in terms of speed, whereas they did in terms of accuracy. Also, rats with lesions did not improve further in overall performance as compared to pre-lesion values, whereas controls did. These results support previous results that neostriatal dopamine is involved in instrumental behaviour in general. Also, these lesions are not sufficient to completely abolish sequential performance, at least when acquired before lesion as tested here.
Davies, Jeff K; Hassan, Sandra; Sarker, Shah-Jalal; Besley, Caroline; Oakervee, Heather; Smith, Matthew; Taussig, David; Gribben, John G; Cavenagh, Jamie D
2018-02-01
Allogeneic haematopoietic stem-cell transplantation remains the only curative treatment for relapsed/refractory acute myeloid leukaemia (AML) and high-risk myelodysplasia but has previously been limited to patients who achieve remission before transplant. New sequential approaches employing T-cell depleted transplantation directly after chemotherapy show promise but are burdened by viral infection and require donor lymphocyte infusions (DLI) to augment donor chimerism and graft-versus-leukaemia effects. T-replete transplantation in sequential approaches could reduce both viral infection and DLI usage. We therefore performed a single-arm prospective Phase II clinical trial of sequential chemotherapy and T-replete transplantation using reduced-intensity conditioning without planned DLI. The primary endpoint was overall survival. Forty-seven patients with relapsed/refractory AML or high-risk myelodysplasia were enrolled; 43 proceeded to transplantation. High levels of donor chimerism were achieved spontaneously with no DLI. Overall survival of transplanted patients was 45% and 33% at 1 and 3 years. Only one patient developed cytomegalovirus disease. Cumulative incidences of treatment-related mortality and relapse were 35% and 20% at 1 year. Patients with relapsed AML and myelodysplasia had the most favourable outcomes. Late-onset graft-versus-host disease protected against relapse. In conclusion, a T-replete sequential transplantation using reduced-intensity conditioning is feasible for relapsed/refractory AML and myelodysplasia and can deliver graft-versus-leukaemia effects without DLI. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Mues, Sarah; Lilge, Inga; Schönherr, Holger; Kemper, Björn; Schnekenburger, Jürgen
2017-02-01
The major problem of Digital Holographic Microscopy (DHM) long term live cell imaging is that over time most of the tracked cells move out of the image area and other ones move in. Therefore, most of the cells are lost for the evaluation of individual cellular processes. Here, we present an effective solution for this crucial problem of long-term microscopic live cell analysis. We have generated functionalized slides containing areas of 250 μm per 200 μm. These micropatterned biointerfaces consist of passivating polyaclrylamide brushes (PAAm). Inner areas are backfilled with octadecanthiol (ODT), which allows cell attachment. The fouling properties of these surfaces are highly controllable and therefore the defined areas designed for the size our microscopic image areas were effective in keeping all cells inside the rectangles over the selected imaging period.
A path-level exact parallelization strategy for sequential simulation
NASA Astrophysics Data System (ADS)
Peredo, Oscar F.; Baeza, Daniel; Ortiz, Julián M.; Herrero, José R.
2018-01-01
Sequential Simulation is a well known method in geostatistical modelling. Following the Bayesian approach for simulation of conditionally dependent random events, Sequential Indicator Simulation (SIS) method draws simulated values for K categories (categorical case) or classes defined by K different thresholds (continuous case). Similarly, Sequential Gaussian Simulation (SGS) method draws simulated values from a multivariate Gaussian field. In this work, a path-level approach to parallelize SIS and SGS methods is presented. A first stage of re-arrangement of the simulation path is performed, followed by a second stage of parallel simulation for non-conflicting nodes. A key advantage of the proposed parallelization method is to generate identical realizations as with the original non-parallelized methods. Case studies are presented using two sequential simulation codes from GSLIB: SISIM and SGSIM. Execution time and speedup results are shown for large-scale domains, with many categories and maximum kriging neighbours in each case, achieving high speedup results in the best scenarios using 16 threads of execution in a single machine.
Barriga-Rivera, Alejandro; Morley, John W; Lovell, Nigel H; Suaning, Gregg J
2016-08-01
Researchers continue to develop visual prostheses towards safer and more efficacious systems. However limitations still exist in the number of stimulating channels that can be integrated. Therefore there is a need for spatial and time multiplexing techniques to provide improved performance of the current technology. In particular, bright and high-contrast visual scenes may require simultaneous activation of several electrodes. In this research, a 24-electrode array was suprachoroidally implanted in three normally-sighted cats. Multi-unit activity was recorded from the primary visual cortex. Four stimulation strategies were contrasted to provide activation of seven electrodes arranged hexagonally: simultaneous monopolar, sequential monopolar, sequential bipolar and hexapolar. Both monopolar configurations showed similar cortical activation maps. Hexapolar and sequential bipolar configurations activated a lower number of cortical channels. Overall, the return configuration played a more relevant role in cortical activation than time multiplexing and thus, rapid sequential stimulation may assist in reducing the number of channels required to activate large retinal areas.
2007-02-01
which is used by the model to drive the normal activities of the crew (Figure C.1-2). These routines consist of a sequential list of high- level...separately. Figure C.1-3: Resources & Logic Sheet C.1.1.4 Scenario The scenario that is performed during a model run is a sequential list of all...were marked with a white fore and aft lineup stripe on both landing spots. Current Sea Fighter design does not provide a hangar; however, there
Transition play in team performance of volleyball: a log-linear analysis.
Eom, H J; Schutz, R W
1992-09-01
The purpose of this study was to develop and test a method to analyze and evaluate sequential skill performances in a team sport. An on-line computerized system was developed to record and summarize the sequential skill performances in volleyball. Seventy-two sample games from the third Federation of International Volleyball Cup men's competition were videotaped and grouped into two categories according to the final team standing and game outcome. Log-linear procedures were used to investigate the nature and degree of the relationship in the first-order (pass-to-set, set-to-spike) and second-order (pass-to-spike) transition plays. Results showed that there was a significant dependency in both the first-order and second-order transition plays, indicating that the outcome of a skill performance is highly influenced by the quality of a preceding skill performance. In addition, the pattern of the transition plays was stable and consistent, regardless of the classification status: Game Outcome, Team Standing, or Transition Process. The methodology and subsequent results provide valuable aids for a thorough understanding of the characteristics of transition plays in volleyball. In addition, the concept of sequential performance analysis may serve as an example for sport scientists in investigating probabilistic patterns of motor performance.
NASA Technical Reports Server (NTRS)
Layland, J. W.
1974-01-01
An approximate analysis of the effect of a noisy carrier reference on the performance of sequential decoding is presented. The analysis uses previously developed techniques for evaluating noisy reference performance for medium-rate uncoded communications adapted to sequential decoding for data rates of 8 to 2048 bits/s. In estimating the ten to the minus fourth power deletion probability thresholds for Helios, the model agrees with experimental data to within the experimental tolerances. The computational problem involved in sequential decoding, carrier loop effects, the main characteristics of the medium-rate model, modeled decoding performance, and perspectives on future work are discussed.
Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon
2018-05-18
Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Simultaneous Versus Sequential Ptosis and Strabismus Surgery in Children.
Revere, Karen E; Binenbaum, Gil; Li, Jonathan; Mills, Monte D; Katowitz, William R; Katowitz, James A
The authors sought to compare the clinical outcomes of simultaneous versus sequential ptosis and strabismus surgery in children. Retrospective, single-center cohort study of children requiring both ptosis and strabismus surgery on the same eye. Simultaneous surgeries were performed during a single anesthetic event; sequential surgeries were performed at least 7 weeks apart. Outcomes were ptosis surgery success (margin reflex distance 1 ≥ 2 mm, good eyelid contour, and good eyelid crease); strabismus surgery success (ocular alignment within 10 prism diopters of orthophoria and/or improved head position); surgical complications; and reoperations. Fifty-six children were studied, 38 had simultaneous surgery and 18 sequential. Strabismus surgery was performed first in 38/38 simultaneous and 6/18 sequential cases. Mean age at first surgery was 64 months, with mean follow up 27 months. A total of 75% of children had congenital ptosis; 64% had comitant strabismus. A majority of ptosis surgeries were frontalis sling (59%) or Fasanella-Servat (30%) procedures. There were no significant differences between simultaneous and sequential groups with regards to surgical success rates, complications, or reoperations (all p > 0.28). In the first comparative study of simultaneous versus sequential ptosis and strabismus surgery, no advantage for sequential surgery was seen. Despite a theoretical risk of postoperative eyelid malposition or complications when surgeries were performed in a combined manner, the rate of such outcomes was not increased with simultaneous surgeries. Performing ptosis and strabismus surgery together appears to be clinically effective and safe, and reduces anesthesia exposure during childhood.
Analysis of filter tuning techniques for sequential orbit determination
NASA Technical Reports Server (NTRS)
Lee, T.; Yee, C.; Oza, D.
1995-01-01
This paper examines filter tuning techniques for a sequential orbit determination (OD) covariance analysis. Recently, there has been a renewed interest in sequential OD, primarily due to the successful flight qualification of the Tracking and Data Relay Satellite System (TDRSS) Onboard Navigation System (TONS) using Doppler data extracted onboard the Extreme Ultraviolet Explorer (EUVE) spacecraft. TONS computes highly accurate orbit solutions onboard the spacecraft in realtime using a sequential filter. As the result of the successful TONS-EUVE flight qualification experiment, the Earth Observing System (EOS) AM-1 Project has selected TONS as the prime navigation system. In addition, sequential OD methods can be used successfully for ground OD. Whether data are processed onboard or on the ground, a sequential OD procedure is generally favored over a batch technique when a realtime automated OD system is desired. Recently, OD covariance analyses were performed for the TONS-EUVE and TONS-EOS missions using the sequential processing options of the Orbit Determination Error Analysis System (ODEAS). ODEAS is the primary covariance analysis system used by the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD). The results of these analyses revealed a high sensitivity of the OD solutions to the state process noise filter tuning parameters. The covariance analysis results show that the state estimate error contributions from measurement-related error sources, especially those due to the random noise and satellite-to-satellite ionospheric refraction correction errors, increase rapidly as the state process noise increases. These results prompted an in-depth investigation of the role of the filter tuning parameters in sequential OD covariance analysis. This paper analyzes how the spacecraft state estimate errors due to dynamic and measurement-related error sources are affected by the process noise level used. This information is then used to establish guidelines for determining optimal filter tuning parameters in a given sequential OD scenario for both covariance analysis and actual OD. Comparisons are also made with corresponding definitive OD results available from the TONS-EUVE analysis.
NASA Technical Reports Server (NTRS)
Marvit, Maclen (Inventor); Kirkham, Harold (Inventor)
1995-01-01
The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs a remote node polling process performed by a master node by transmitting a polling message generically addressed to all remote nodes associated with the master node. Each remote node responds upon receipt of the generically addressed polling message by sequentially flooding the network with a poll-answering informational message and with the polling message.
NASA Astrophysics Data System (ADS)
Park, Hyun-Woo; Song, Aeran; Kwon, Sera; Choi, Dukhyun; Kim, Younghak; Jun, Byung-Hyuk; Kim, Han-Ki; Chung, Kwun-Bum
2018-03-01
This study suggests a sequential ambient annealing process as an excellent post-treatment method to enhance the device performance and stability of W (tungsten) doped InZnO thin film transistors (WIZO-TFTs). Sequential ambient annealing at 250 °C significantly enhanced the device performance and stability of WIZO-TFTs, compared with other post-treatment methods, such as air ambient annealing and vacuum ambient annealing at 250 °C. To understand the enhanced device performance and stability of WIZO-TFT with sequential ambient annealing, we investigate the correlations between device performance and stability and electronic structures, such as band alignment, a feature of the conduction band, and band edge states below the conduction band. The enhanced performance of WIZO-TFTs with sequential ambient annealing is related to the modification of the electronic structure. In addition, the dominant mechanism responsible for the enhanced device performance and stability of WIZO-TFTs is considered to be a change in the shallow-level and deep-level band edge states below the conduction band.
Zhang, Jia-yu; Wang, Zi-jian; Li, Yun; Liu, Ying; Cai, Wei; Li, Chen; Lu, Jian-qiu; Qiao, Yan-jiang
2016-01-15
The analytical methodologies for evaluation of multi-component system in traditional Chinese medicines (TCMs) have been inadequate or unacceptable. As a result, the unclarity of multi-component hinders the sufficient interpretation of their bioactivities. In this paper, an ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap (UPLC-LTQ-Orbitrap)-based strategy focused on the comprehensive identification of TCM sequential constituents was developed. The strategy was characterized by molecular design, multiple ion monitoring (MIM), targeted database hits and mass spectral trees similarity filter (MTSF), and even more isomerism discrimination. It was successfully applied in the HRMS data-acquisition and processing of chlorogenic acids (CGAs) in Flos Lonicerae Japonicae (FLJ), and a total of 115 chromatographic peaks attributed to 18 categories were characterized, allowing a comprehensive revelation of CGAs in FLJ for the first time. This demonstrated that MIM based on molecular design could improve the efficiency to trigger MS/MS fragmentation reactions. Targeted database hits and MTSF searching greatly facilitated the processing of extremely large information data. Besides, the introduction of diagnostic product ions (DPIs) discrimination, ClogP analysis, and molecular simulation, raised the efficiency and accuracy to characterize sequential constituents especially position and geometric isomers. In conclusion, the results expanded our understanding on CGAs in FLJ, and the strategy could be exemplary for future research on the comprehensive identification of sequential constituents in TCMs. Meanwhile, it may propose a novel idea for analyzing sequential constituents, and is promising for quality control and evaluation of TCMs. Copyright © 2015 Elsevier B.V. All rights reserved.
Success Teaching Spelling with Music.
ERIC Educational Resources Information Center
Martin, Mariellen
1983-01-01
A spelling approach which incorporates music on a cassette with spelling, pronunciation, and definition of specific words was successful in improving junior high learning disabled students' spelling performance, self-esteem, and sequential memories. (CL)
Moehler, Tobias; Fiehler, Katja
2015-11-01
Saccade curvature represents a sensitive measure of oculomotor inhibition with saccades curving away from covertly attended locations. Here we investigated whether and how saccade curvature depends on movement preparation time when a perceptual task is performed during or before saccade preparation. Participants performed a dual-task including a visual discrimination task at a cued location and a saccade task to the same location (congruent) or to a different location (incongruent). Additionally, we varied saccade preparation time (time between saccade cue and Go-signal) and the occurrence of the discrimination task (during saccade preparation=simultaneous vs. before saccade preparation=sequential). We found deteriorated perceptual performance in incongruent trials during simultaneous task performance while perceptual performance was unaffected during sequential task performance. Saccade accuracy and precision were deteriorated in incongruent trials during simultaneous and, to a lesser extent, also during sequential task performance. Saccades consistently curved away from covertly attended non-saccade locations. Saccade curvature was unaffected by movement preparation time during simultaneous task performance but decreased and finally vanished with increasing movement preparation time during sequential task performance. Our results indicate that the competing saccade plan to the covertly attended non-saccade location is maintained during simultaneous task performance until the perceptual task is solved while in the sequential condition, in which the discrimination task is solved prior to the saccade task, oculomotor inhibition decays gradually with movement preparation time. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sequential-Simultaneous Analysis of Japanese Children's Performance on the Japanese McCarthy.
ERIC Educational Resources Information Center
Ishikuma, Toshinori; And Others
This study explored the hypothesis that Japanese children perform significantly better on simultaneous processing than on sequential processing. The Kaufman Assessment Battery for Children (K-ABC) served as the criterion of the two types of mental processing. Regression equations to predict Sequential and Simultaneous processing from McCarthy…
Cost-effectiveness of simultaneous versus sequential surgery in head and neck reconstruction.
Wong, Kevin K; Enepekides, Danny J; Higgins, Kevin M
2011-02-01
To determine whether simultaneous (ablation and reconstruction overlaps by two teams) head and neck reconstruction is cost effective compared to sequentially (ablation followed by reconstruction) performed surgery. Case-controlled study. Tertiary care hospital. Oncology patients undergoing free flap reconstruction of the head and neck. A match paired comparison study was performed with a retrospective chart review examining the total time of surgery for sequential and simultaneous surgery. Nine patients were selected for both the sequential and simultaneous groups. Sequential head and neck reconstruction patients were pair matched with patients who had undergone similar oncologic ablative or reconstructive procedures performed in a simultaneous fashion. A detailed cost analysis using the microcosting method was then undertaken looking at the direct costs of the surgeons, anesthesiologist, operating room, and nursing. On average, simultaneous surgery required 3 hours 15 minutes less operating time, leading to a cost savings of approximately $1200/case when compared to sequential surgery. This represents approximately a 15% reduction in the cost of the entire operation. Simultaneous head and neck reconstruction is more cost effective when compared to sequential surgery.
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics.
Kim, Dae-Hyeong; Viventi, Jonathan; Amsden, Jason J; Xiao, Jianliang; Vigeland, Leif; Kim, Yun-Soung; Blanco, Justin A; Panilaitis, Bruce; Frechette, Eric S; Contreras, Diego; Kaplan, David L; Omenetto, Fiorenzo G; Huang, Yonggang; Hwang, Keh-Chih; Zakin, Mitchell R; Litt, Brian; Rogers, John A
2010-06-01
Electronics that are capable of intimate, non-invasive integration with the soft, curvilinear surfaces of biological tissues offer important opportunities for diagnosing and treating disease and for improving brain/machine interfaces. This article describes a material strategy for a type of bio-interfaced system that relies on ultrathin electronics supported by bioresorbable substrates of silk fibroin. Mounting such devices on tissue and then allowing the silk to dissolve and resorb initiates a spontaneous, conformal wrapping process driven by capillary forces at the biotic/abiotic interface. Specialized mesh designs and ultrathin forms for the electronics ensure minimal stresses on the tissue and highly conformal coverage, even for complex curvilinear surfaces, as confirmed by experimental and theoretical studies. In vivo, neural mapping experiments on feline animal models illustrate one mode of use for this class of technology. These concepts provide new capabilities for implantable and surgical devices.
Dissolvable Films of Silk Fibroin for Ultrathin, Conformal Bio-Integrated Electronics
Kim, Dae-Hyeong; Viventi, Jonathan; Amsden, Jason J.; Xiao, Jianliang; Vigeland, Leif; Kim, Yun-Soung; Blanco, Justin A.; Panilaitis, Bruce; Frechette, Eric S.; Contreras, Diego; Kaplan, David L.; Omenetto, Fiorenzo G.; Huang, Yonggang; Hwang, Keh-Chih; Zakin, Mitchell R.; Litt, Brian; Rogers, John A.
2011-01-01
Electronics that are capable of intimate, non-invasive integration with the soft, curvilinear surfaces of biological tissues offer important opportunities for diagnosing and treating disease and for improving brain-machine interfaces. This paper describes a material strategy for a type of bio-interfaced system that relies on ultrathin electronics supported by bioresorbable substrates of silk fibroin. Mounting such devices on tissue and then allowing the silk to dissolve and resorb initiates a spontaneous, conformal wrapping process driven by capillary forces at the biotic/abiotic interface. Specialized mesh designs and ultrathin forms for the electronics ensure minimal stresses on the tissue and highly conformal coverage, even for complex curvilinear surfaces, as confirmed by experimental and theoretical studies. In vivo, neural mapping experiments on feline animal models illustrate one mode of use for this class of technology. These concepts provide new capabilities for implantable or surgical devices. PMID:20400953
NASA Astrophysics Data System (ADS)
Fu, Qiang; Schaaf, Peter
2018-07-01
This special issue of the high impact international peer reviewed journal Applied Surface Science represents the proceedings of the 2nd International Conference on Applied Surface Science ICASS held 12-16 June 2017 in Dalian China. The conference provided a forum for researchers in all areas of applied surface science to present their work. The main topics of the conference are in line with the most popular areas of research reported in Applied Surface Science. Thus, this issue includes current research on the role and use of surfaces in chemical and physical processes, related to catalysis, electrochemistry, surface engineering and functionalization, biointerfaces, semiconductors, 2D-layered materials, surface nanotechnology, energy, new/functional materials and nanotechnology. Also the various techniques and characterization methods will be discussed. Hence, scientific research on the atomic and molecular level of material properties investigated with specific surface analytical techniques and/or computational methods is essential for any further progress in these fields.
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
NASA Astrophysics Data System (ADS)
Kim, Dae-Hyeong; Viventi, Jonathan; Amsden, Jason J.; Xiao, Jianliang; Vigeland, Leif; Kim, Yun-Soung; Blanco, Justin A.; Panilaitis, Bruce; Frechette, Eric S.; Contreras, Diego; Kaplan, David L.; Omenetto, Fiorenzo G.; Huang, Yonggang; Hwang, Keh-Chih; Zakin, Mitchell R.; Litt, Brian; Rogers, John A.
2010-06-01
Electronics that are capable of intimate, non-invasive integration with the soft, curvilinear surfaces of biological tissues offer important opportunities for diagnosing and treating disease and for improving brain/machine interfaces. This article describes a material strategy for a type of bio-interfaced system that relies on ultrathin electronics supported by bioresorbable substrates of silk fibroin. Mounting such devices on tissue and then allowing the silk to dissolve and resorb initiates a spontaneous, conformal wrapping process driven by capillary forces at the biotic/abiotic interface. Specialized mesh designs and ultrathin forms for the electronics ensure minimal stresses on the tissue and highly conformal coverage, even for complex curvilinear surfaces, as confirmed by experimental and theoretical studies. In vivo, neural mapping experiments on feline animal models illustrate one mode of use for this class of technology. These concepts provide new capabilities for implantable and surgical devices.
Dry minor mergers and size evolution of high-z compact massive early-type galaxies
NASA Astrophysics Data System (ADS)
Oogi, Taira; Habe, Asao
2012-09-01
Recent observations show evidence that high-z (z ~ 2 - 3) early-type galaxies (ETGs) are quite compact than that with comparable mass at z ~ 0. Dry merger scenario is one of the most probable one that can explain such size evolution. However, previous studies based on this scenario do not succeed to explain both properties of high-z compact massive ETGs and local ETGs, consistently. We investigate effects of sequential, multiple dry minor (stellar mass ratio M2/M1<1/4) mergers on the size evolution of compact massive ETGs. We perform N-body simulations of the sequential minor mergers with parabolic and head-on orbits, including a dark matter component and a stellar component. We show that the sequential minor mergers of compact satellite galaxies are the most efficient in the size growth and in decrease of the velocity dispersion of the compact massive ETGs. The change of stellar size and density of the merger remnant is consistent with the recent observations. Furthermore, we construct the merger histories of candidates of high-z compact massive ETGs using the Millennium Simulation Database, and estimate the size growth of the galaxies by dry minor mergers. We can reproduce the mean size growth factor between z = 2 and z = 0, assuming the most efficient size growth obtained in the case of the sequential minor mergers in our simulations.
Kim, Myeong-Seong; Bak, Seong-Min; Lee, Suk-Woo; ...
2017-09-26
Here in this paper, we report on Li 3V 2(PO 4) 3 (LVP)/reduced graphene oxide (rGO) multilayer composites prepared via a sequential adsorption method and subsequent heat treatment, and their use as cathodes for high-rate lithium-ion batteries. The sequential adsorption process includes adsorbing oppositely charged components of anionic inorganic species and cationic head of a surfactant adsorbed to graphite oxide sheets, which is a key step in the fabrication of the LVP/rGO multilayer composites. The multilayer structure has open channels between the highly conductive rGO layers while achieving a relatively high tap density, which could effectively improve the rate capability.more » Consequently, the LVP/rGO multilayer composites exhibit a high tap density (0.6 g cm -3) and good electrochemical properties. Specifically, in the voltage range of 3.0–4.3 V, the composite exhibits a specific capacity of 131 mAh g -1 at 0.1C, a good rate capabilities (88% capacity retention at 60C), and long cycling performance (97% capacity retention after 500 cycles at 10C). Moreover, in the extended voltage range of 3.0–4.8 V, it exhibits a high specific capacity of 185 mAh g -1 at 0.2C, a good rate capability (66% capacity retention at 30C), and stable cycling performance (96% capacity retention after 500 cycles at 10C).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Myeong-Seong; Bak, Seong-Min; Lee, Suk-Woo
Here in this paper, we report on Li 3V 2(PO 4) 3 (LVP)/reduced graphene oxide (rGO) multilayer composites prepared via a sequential adsorption method and subsequent heat treatment, and their use as cathodes for high-rate lithium-ion batteries. The sequential adsorption process includes adsorbing oppositely charged components of anionic inorganic species and cationic head of a surfactant adsorbed to graphite oxide sheets, which is a key step in the fabrication of the LVP/rGO multilayer composites. The multilayer structure has open channels between the highly conductive rGO layers while achieving a relatively high tap density, which could effectively improve the rate capability.more » Consequently, the LVP/rGO multilayer composites exhibit a high tap density (0.6 g cm -3) and good electrochemical properties. Specifically, in the voltage range of 3.0–4.3 V, the composite exhibits a specific capacity of 131 mAh g -1 at 0.1C, a good rate capabilities (88% capacity retention at 60C), and long cycling performance (97% capacity retention after 500 cycles at 10C). Moreover, in the extended voltage range of 3.0–4.8 V, it exhibits a high specific capacity of 185 mAh g -1 at 0.2C, a good rate capability (66% capacity retention at 30C), and stable cycling performance (96% capacity retention after 500 cycles at 10C).« less
Nanopatterned polymer brushes: conformation, fabrication and applications.
Yu, Qian; Ista, Linnea K; Gu, Renpeng; Zauscher, Stefan; López, Gabriel P
2016-01-14
Surfaces with end-grafted, nanopatterned polymer brushes that exhibit well-defined feature dimensions and controlled chemical and physical properties provide versatile platforms not only for investigation of nanoscale phenomena at biointerfaces, but also for the development of advanced devices relevant to biotechnology and electronics applications. In this review, we first give a brief introduction of scaling behavior of nanopatterned polymer brushes and then summarize recent progress in fabrication and application of nanopatterned polymer brushes. Specifically, we highlight applications of nanopatterned stimuli-responsive polymer brushes in the areas of biomedicine and biotechnology.
Nanopatterned polymer brushes: conformation, fabrication and applications
NASA Astrophysics Data System (ADS)
Yu, Qian; Ista, Linnea K.; Gu, Renpeng; Zauscher, Stefan; López, Gabriel P.
2015-12-01
Surfaces with end-grafted, nanopatterned polymer brushes that exhibit well-defined feature dimensions and controlled chemical and physical properties provide versatile platforms not only for investigation of nanoscale phenomena at biointerfaces, but also for the development of advanced devices relevant to biotechnology and electronics applications. In this review, we first give a brief introduction of scaling behavior of nanopatterned polymer brushes and then summarize recent progress in fabrication and application of nanopatterned polymer brushes. Specifically, we highlight applications of nanopatterned stimuli-responsive polymer brushes in the areas of biomedicine and biotechnology.
Wakamiya, Eiji; Okumura, Tomohito; Nakanishi, Makoto; Takeshita, Takashi; Mizuta, Mekumi; Kurimoto, Naoko; Tamai, Hiroshi
2011-06-01
To clarify whether rapid naming ability itself is a main underpinning factor of rapid automatized naming tests (RAN) and how deep an influence the discrete decoding process has on reading, we performed discrete naming tasks and discrete hiragana reading tasks as well as sequential naming tasks and sequential hiragana reading tasks with 38 Japanese schoolchildren with reading difficulty. There were high correlations between both discrete and sequential hiragana reading and sentence reading, suggesting that some mechanism which automatizes hiragana reading makes sentence reading fluent. In object and color tasks, there were moderate correlations between sentence reading and sequential naming, and between sequential naming and discrete naming. But no correlation was found between reading tasks and discrete naming tasks. The influence of rapid naming ability of objects and colors upon reading seemed relatively small, and multi-item processing may work in relation to these. In contrast, in the digit naming task there was moderate correlation between sentence reading and discrete naming, while no correlation was seen between sequential naming and discrete naming. There was moderate correlation between reading tasks and sequential digit naming tasks. Digit rapid naming ability has more direct effect on reading while its effect on RAN is relatively limited. The ratio of how rapid naming ability influences RAN and reading seems to vary according to kind of the stimuli used. An assumption about components in RAN which influence reading is discussed in the context of both sequential processing and discrete naming speed. Copyright © 2010 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Damisch, Lysann; Mussweiler, Thomas; Plessner, Henning
2006-01-01
The authors investigated the evaluative consequences of sequential performance judgments. Recent social comparison research has suggested that performance judgments may be influenced by judgments about a preceding performance. Specifically, performance judgments may be assimilated to judgments of the preceding performance if judges focus on…
Sequential Effects on Speeded Information Processing: A Developmental Study
ERIC Educational Resources Information Center
Smulders, S.F.A.; Notebaert, W.; Meijer, M.; Crone, E.A.; van der Molen, M.W.; Soetens, E.
2005-01-01
Two experiments were performed to assess age-related changes in sequential effects on choice reaction time (RT). Sequential effects portray the influence of previous trials on the RT to the current stimulus. In Experiment 1, three age groups (7-9, 10-12, and 18-25 years) performed a spatially compatible choice task, with response-to-stimulus…
Quarello, Paola; Tandoi, Francesco; Carraro, Francesca; Vassallo, Elena; Pinon, Michele; Romagnoli, Renato; David, Ezio; Dell Olio, Dominic; Salizzoni, Mauro; Fagioli, Franca; Calvo, Pier Luigi
2018-05-01
Hematopoietic stem cell transplantation (HSCT) is curative in patients with primary immunodeficiencies. However, pre-HSCT conditioning entails unacceptably high risks if the liver is compromised. The presence of a recurrent opportunistic infection affecting the biliary tree and determining liver cirrhosis with portal hypertension posed particular decisional difficulties in a 7-year-old child with X-linked CD40-ligand deficiency. We aim at adding to the scanty experience available on such rare cases, as successful management with sequential liver transplantation (LT) and HSCT has been reported in detail only in 1 young adult to date. A closely sequential strategy, with a surgical complication-free LT, followed by reduced-intensity conditioning, allowed HSCT to be performed only one month after LT, preventing Cryptosporidium parvum recolonization of the liver graft. Combined sequential LT and HSCT resolved the cirrhotic evolution and corrected the immunodeficiency so that the infection responsible for the progressive sclerosing cholangitis did not recur. Hopefully, this report of the successful resolution of a potentially fatal combination of immunodeficiency and chronic opportunistic infection with end-stage organ damage in a child will encourage others to adapt a sequential transplant approach to this highly complex pathology. However, caution is to be exercised to carefully balance the risks intrinsic to transplant surgery and immunosuppression in primary immunodeficiencies.
Computational Particle Dynamic Simulations on Multicore Processors (CPDMu) Final Report Phase I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmalz, Mark S
2011-07-24
Statement of Problem - Department of Energy has many legacy codes for simulation of computational particle dynamics and computational fluid dynamics applications that are designed to run on sequential processors and are not easily parallelized. Emerging high-performance computing architectures employ massively parallel multicore architectures (e.g., graphics processing units) to increase throughput. Parallelization of legacy simulation codes is a high priority, to achieve compatibility, efficiency, accuracy, and extensibility. General Statement of Solution - A legacy simulation application designed for implementation on mainly-sequential processors has been represented as a graph G. Mathematical transformations, applied to G, produce a graph representation {und G}more » for a high-performance architecture. Key computational and data movement kernels of the application were analyzed/optimized for parallel execution using the mapping G {yields} {und G}, which can be performed semi-automatically. This approach is widely applicable to many types of high-performance computing systems, such as graphics processing units or clusters comprised of nodes that contain one or more such units. Phase I Accomplishments - Phase I research decomposed/profiled computational particle dynamics simulation code for rocket fuel combustion into low and high computational cost regions (respectively, mainly sequential and mainly parallel kernels), with analysis of space and time complexity. Using the research team's expertise in algorithm-to-architecture mappings, the high-cost kernels were transformed, parallelized, and implemented on Nvidia Fermi GPUs. Measured speedups (GPU with respect to single-core CPU) were approximately 20-32X for realistic model parameters, without final optimization. Error analysis showed no loss of computational accuracy. Commercial Applications and Other Benefits - The proposed research will constitute a breakthrough in solution of problems related to efficient parallel computation of particle and fluid dynamics simulations. These problems occur throughout DOE, military and commercial sectors: the potential payoff is high. We plan to license or sell the solution to contractors for military and domestic applications such as disaster simulation (aerodynamic and hydrodynamic), Government agencies (hydrological and environmental simulations), and medical applications (e.g., in tomographic image reconstruction). Keywords - High-performance Computing, Graphic Processing Unit, Fluid/Particle Simulation. Summary for Members of Congress - Department of Energy has many simulation codes that must compute faster, to be effective. The Phase I research parallelized particle/fluid simulations for rocket combustion, for high-performance computing systems.« less
Movement of particles using sequentially activated dielectrophoretic particle trapping
Miles, Robin R.
2004-02-03
Manipulation of DNA and cells/spores using dielectrophoretic (DEP) forces to perform sample preparation protocols for polymerized chain reaction (PCR) based assays for various applications. This is accomplished by movement of particles using sequentially activated dielectrophoretic particle trapping. DEP forces induce a dipole in particles, and these particles can be trapped in non-uniform fields. The particles can be trapped in the high field strength region of one set of electrodes. By switching off this field and switching on an adjacent electrodes, particles can be moved down a channel with little or no flow.
Evaluation of head orientation and neck muscle EMG signals as three-dimensional command sources.
Williams, Matthew R; Kirsch, Robert F
2015-03-05
High cervical spinal cord injuries result in significant functional impairments and affect both the injured individual as well as their family and care givers. To help restore function to these individuals, multiple user interfaces are available to enable command and control of external devices. However, little work has been performed to assess the 3D performance of these interfaces. We investigated the performance of eight human subjects in using three user interfaces (head orientation, EMG from muscles of the head and neck, and a three-axis joystick) to command the endpoint position of a multi-axis robotic arm within a 3D workspace to perform a novel out-to-center 3D Fitts' Law style task. Two of these interfaces (head orientation, EMG from muscles of the head and neck) could realistically be used by individuals with high tetraplegia, while the joystick was evaluated as a standard of high performance. Performance metrics were developed to assess the aspects of command source performance. Data were analyzed using a mixed model design ANOVA. Fixed effects were investigated between sources as well as for interactions between index of difficulty, command source, and the five performance measures used. A 5% threshold for statistical significance was used in the analysis. The performances of the three command interfaces were rather similar, though significant differences between command sources were observed. The apparent similarity is due in large part to the sequential command strategy (i.e., one dimension of movement at a time) typically adopted by the subjects. EMG-based commands were particularly pulsatile in nature. The use of sequential commands had a significant impact on each command source's performance for movements in two or three dimensions. While the sequential nature of the commands produced by the user did not fit with Fitts' Law, the other performance measures used were able to illustrate the properties of each command source. Though pulsatile, given the overall similarity between head orientation and the EMG interface, (which also could be readily included in a future implanted neuroprosthesis) the use of EMG as a command source for controlling an arm in 3D space is an attractive choice.
Li, Guoqi; Deng, Lei; Wang, Dong; Wang, Wei; Zeng, Fei; Zhang, Ziyang; Li, Huanglong; Song, Sen; Pei, Jing; Shi, Luping
2016-01-01
Chunking refers to a phenomenon whereby individuals group items together when performing a memory task to improve the performance of sequential memory. In this work, we build a bio-plausible hierarchical chunking of sequential memory (HCSM) model to explain why such improvement happens. We address this issue by linking hierarchical chunking with synaptic plasticity and neuromorphic engineering. We uncover that a chunking mechanism reduces the requirements of synaptic plasticity since it allows applying synapses with narrow dynamic range and low precision to perform a memory task. We validate a hardware version of the model through simulation, based on measured memristor behavior with narrow dynamic range in neuromorphic circuits, which reveals how chunking works and what role it plays in encoding sequential memory. Our work deepens the understanding of sequential memory and enables incorporating it for the investigation of the brain-inspired computing on neuromorphic architecture. PMID:28066223
Epithelial self-healing is recapitulated by a 3D biomimetic E-cadherin junction.
Cohen, Daniel J; Gloerich, Martijn; Nelson, W James
2016-12-20
Epithelial monolayers undergo self-healing when wounded. During healing, cells collectively migrate into the wound site, and the converging tissue fronts collide and form a stable interface. To heal, migrating tissues must form cell-cell adhesions and reorganize from the front-rear polarity characteristic of cell migration to the apical-basal polarity of an epithelium. However, identifying the "stop signal" that induces colliding tissues to cease migrating and heal remains an open question. Epithelial cells form integrin-based adhesions to the basal extracellular matrix (ECM) and E-cadherin-mediated cell-cell adhesions on the orthogonal, lateral surfaces between cells. Current biological tools have been unable to probe this multicellular 3D interface to determine the stop signal. We addressed this problem by developing a unique biointerface that mimicked the 3D organization of epithelial cell adhesions. This "minimal tissue mimic" (MTM) comprised a basal ECM substrate and a vertical surface coated with purified extracellular domain of E-cadherin, and was designed for collision with the healing edge of an epithelial monolayer. Three-dimensional imaging showed that adhesions formed between cells, and the E-cadherin-coated MTM resembled the morphology and dynamics of native epithelial cell-cell junctions and induced the same polarity transition that occurs during epithelial self-healing. These results indicate that E-cadherin presented in the proper 3D context constitutes a minimum essential stop signal to induce self-healing. That the Ecad:Fc MTM stably integrated into an epithelial tissue and reduced migration at the interface suggests that this biointerface is a complimentary approach to existing tissue-material interfaces.
Epithelial self-healing is recapitulated by a 3D biomimetic E-cadherin junction
Cohen, Daniel J.; Gloerich, Martijn; Nelson, W. James
2016-01-01
Epithelial monolayers undergo self-healing when wounded. During healing, cells collectively migrate into the wound site, and the converging tissue fronts collide and form a stable interface. To heal, migrating tissues must form cell–cell adhesions and reorganize from the front-rear polarity characteristic of cell migration to the apical-basal polarity of an epithelium. However, identifying the "stop signal" that induces colliding tissues to cease migrating and heal remains an open question. Epithelial cells form integrin-based adhesions to the basal extracellular matrix (ECM) and E-cadherin–mediated cell–cell adhesions on the orthogonal, lateral surfaces between cells. Current biological tools have been unable to probe this multicellular 3D interface to determine the stop signal. We addressed this problem by developing a unique biointerface that mimicked the 3D organization of epithelial cell adhesions. This "minimal tissue mimic" (MTM) comprised a basal ECM substrate and a vertical surface coated with purified extracellular domain of E-cadherin, and was designed for collision with the healing edge of an epithelial monolayer. Three-dimensional imaging showed that adhesions formed between cells, and the E-cadherin-coated MTM resembled the morphology and dynamics of native epithelial cell–cell junctions and induced the same polarity transition that occurs during epithelial self-healing. These results indicate that E-cadherin presented in the proper 3D context constitutes a minimum essential stop signal to induce self-healing. That the Ecad:Fc MTM stably integrated into an epithelial tissue and reduced migration at the interface suggests that this biointerface is a complimentary approach to existing tissue–material interfaces. PMID:27930308
Biointerface dynamics--Multi scale modeling considerations.
Pajic-Lijakovic, Ivana; Levic, Steva; Nedovic, Viktor; Bugarski, Branko
2015-08-01
Irreversible nature of matrix structural changes around the immobilized cell aggregates caused by cell expansion is considered within the Ca-alginate microbeads. It is related to various effects: (1) cell-bulk surface effects (cell-polymer mechanical interactions) and cell surface-polymer surface effects (cell-polymer electrostatic interactions) at the bio-interface, (2) polymer-bulk volume effects (polymer-polymer mechanical and electrostatic interactions) within the perturbed boundary layers around the cell aggregates, (3) cumulative surface and volume effects within the parts of the microbead, and (4) macroscopic effects within the microbead as a whole based on multi scale modeling approaches. All modeling levels are discussed at two time scales i.e. long time scale (cell growth time) and short time scale (cell rearrangement time). Matrix structural changes results in the resistance stress generation which have the feedback impact on: (1) single and collective cell migrations, (2) cell deformation and orientation, (3) decrease of cell-to-cell separation distances, and (4) cell growth. Herein, an attempt is made to discuss and connect various multi scale modeling approaches on a range of time and space scales which have been proposed in the literature in order to shed further light to this complex course-consequence phenomenon which induces the anomalous nature of energy dissipation during the structural changes of cell aggregates and matrix quantified by the damping coefficients (the orders of the fractional derivatives). Deeper insight into the matrix partial disintegration within the boundary layers is useful for understanding and minimizing the polymer matrix resistance stress generation within the interface and on that base optimizing cell growth. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rusen, Laurentiu; Neacsu, Patricia; Cimpean, Anisoara; Valentin, Ion; Brajnicov, Simona; Dumitrescu, L. N.; Banita, Janina; Dinca, Valentina; Dinescu, Maria
2016-06-01
Understanding and controlling natural and synthetic biointerfaces is known to be the key to a wide variety of application within cell culture and tissue engineering field. As both material characteristics and methods are important in tailoring biointerfaces characteristics, in this work we explore the feasibility of using Matrix Assisted Pulsed Laser Evaporation technique for obtaining synthetic copolymeric biocoatings (i.e. poly(ethylene glycol)-block-poly(ɛ-caprolactone) methyl ether) for evaluating in vitro Vero and MC3T3-E1 pre-osteoblasts cell response. Characterization and evaluation of the coated substrates were carried out using different techniques. The Fourier transform infrared spectroscopy data demonstrated that the main functional groups in the MAPLE-deposited films remained intact. Atomic Force Microscopy images showed the coatings to be continuous, with the surface roughness depending on the deposition parameters. Moreover, the behaviour of the coatings in medium mimicking the pH and temperature of the human body was studied and corelated to degradation. Spectro-ellipsometry (SE) and AFM measurements revealed the degradation trend during immersion time by the changes in coating thickness and roughness. In vitro biocompatibility was studied by indirect contact tests on Vero cells in accordance with ISO 10993-5/2009. The results obtained in terms of cell morphology (phase contrast microscopy) and cytotoxicity (LDH and MTT assays) proved biocompatibility. Furthermore, direct contact assays on MC3T3-E1 pre-osteoblasts demonstrated the capacity of all analyzed specimens to support cell adhesion, normal cellular morphology and growth.
2017-01-01
Objective Anticipation of opponent actions, through the use of advanced (i.e., pre-event) kinematic information, can be trained using video-based temporal occlusion. Typically, this involves isolated opponent skills/shots presented as trials in a random order. However, two different areas of research concerning representative task design and contextual (non-kinematic) information, suggest this structure of practice restricts expert performance. The aim of this study was to examine the effect of a sequential structure of practice during video-based training of anticipatory behavior in tennis, as well as the transfer of these skills to the performance environment. Methods In a pre-practice-retention-transfer design, participants viewed life-sized video of tennis rallies across practice in either a sequential order (sequential group), in which participants were exposed to opponent skills/shots in the order they occur in the sport, or a non-sequential (non-sequential group) random order. Results In the video-based retention test, the sequential group was significantly more accurate in their anticipatory judgments when the retention condition replicated the sequential structure compared to the non-sequential group. In the non-sequential retention condition, the non-sequential group was more accurate than the sequential group. In the field-based transfer test, overall decision time was significantly faster in the sequential group compared to the non-sequential group. Conclusion Findings highlight the benefits of a sequential structure of practice for the transfer of anticipatory behavior in tennis. We discuss the role of contextual information, and the importance of representative task design, for the testing and training of perceptual-cognitive skills in sport. PMID:28355263
Saadeh, Charles K; Rosero, Eric B; Joshi, Girish P; Ozayar, Esra; Mau, Ted
2017-12-01
To determine the extent to which a sequential anesthetic technique 1) shortens time under sedation for thyroplasty with arytenoid adduction (TP-AA), 2) affects the total operative time, and 3) changes the voice outcome compared to TP-AA performed entirely under sedation/analgesia. Case-control study. A new sequential anesthetic technique of performing most of the TP-AA surgery under general anesthesia (GA), followed by transition to sedation/analgesia (SA) for voice assessment, was developed to achieve smooth emergence from GA. Twenty-five TP-AA cases performed with the sequential GA-SA technique were compared with 25 TP-AA controls performed completely under sedation/analgesia. The primary outcome measure was the time under sedation. Voice improvement, as assessed by Consensus Auditory-Perceptual Evaluation of Voice, and total operative time were secondary outcome measures. With the conventional all-SA anesthetic, the duration of SA was 209 ± 26.3 minutes. With the sequential GA-SA technique, the duration of SA was 79.0 ± 18.9 minutes, a 62.3% reduction (P < 0.0001). There was no significant difference in the total operative time (209.5 vs. 200.9 minutes; P = 0.42) or in voice outcome. This sequential anesthetic technique has been easily adopted by multiple anesthesiologists and nurse anesthetists at our institution. TP-AA is effectively performed under sequential GA-SA technique with a significant reduction in the duration of time under sedation. This allows the surgeon to perform the technically more challenging part of the surgery under GA, without having to contend with variability in patient tolerance for laryngeal manipulation under sedation. 3b. Laryngoscope, 127:2813-2817, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Molecular Design of Antifouling Polymer Brushes Using Sequence-Specific Peptoids.
Lau, King Hang Aaron; Sileika, Tadas S; Park, Sung Hyun; Sousa, Ana Maria Leal; Burch, Patrick; Szleifer, Igal; Messersmith, Phillip B
2015-01-07
Material systems that can be used to flexibly and precisely define the chemical nature and molecular arrangement of a surface would be invaluable for the control of complex biointerfacial interactions. For example, progress in antifouling polymer biointerfaces that prevent non-specific protein adsorption and cell attachment, which can significantly improve the performance of an array of biomedical and industrial applications, is hampered by a lack of chemical models to identify the molecular features conferring their properties. Poly(N-substituted glycine) "peptoids" are peptidomimetic polymers that can be conveniently synthesized with specific monomer sequences and chain lengths, and are presented as a versatile platform for investigating the molecular design of antifouling polymer brushes. Zwitterionic antifouling polymer brushes have captured significant recent attention, and a targeted library of zwitterionic peptoid brushes with a different charge densities, hydration, separations between charged groups, chain lengths, and grafted chain densities, is quantitatively evaluated for their antifouling properties through a range of protein adsorption and cell attachment assays. Specific zwitterionic brush designs were found to give rise to distinct but subtle differences in properties. The results also point to the dominant roles of the grafted chain density and chain length in determining the performance of antifouling polymer brushes.
Xie, Yian; Shao, Feng; Wang, Yaoming; Xu, Tao; Wang, Deliang; Huang, Fuqiang
2015-06-17
Sequential deposition is a widely adopted method to prepare CH3NH3PbI3 on mesostructured TiO2 electrode for organic lead halide perovskite solar cells. However, this method often suffers from the uncontrollable crystal size, surface morphology, and residual PbI2 in the resulting CH3NH3PbI3, which are all detrimental to the device performance. We herein present an optimized sequential solution deposition method by introducing different amount of CH3NH3I in PbI2 precursor solution in the first step to prepare CH3NH3PbI3 absorber on mesoporous TiO2 substrates. The addition of CH3NH3I in PbI2 precursor solution can affect the crystallization and composition of PbI2 raw films, resulting in the variation of UV-vis absorption and surface morphology. Proper addition of CH3NH3I not only enhances the absorption but also improves the efficiency of CH3NH3PbI3 solar cells from 11.13% to 13.37%. Photoluminescence spectra suggest that the improvement of device performance is attributed to the decrease of recombination rate of carriers in CH3NH3PbI3 absorber. This current method provides a highly repeatable route for enhancing the efficiency of CH3NH3PbI3 solar cell in the sequential solution deposition method.
Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax; Grudpan, Kate
2011-07-01
A sequential injection-bead injection-lab-on-valve system was hyphenated to HPLC for online renewable micro-solid-phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep(®) RP-18 beads (25-40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C-18 column (4.6 × 150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1-20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fang, Hui; Zhao, Jianing; Yu, Ki Jun; Song, Enming; Farimani, Amir Barati; Chiang, Chia-Han; Jin, Xin; Xue, Yeguang; Xu, Dong; Du, Wenbo; Seo, Kyung Jin; Zhong, Yiding; Yang, Zijian; Won, Sang Min; Fang, Guanhua; Choi, Seo Woo; Chaudhuri, Santanu; Huang, Yonggang; Alam, Muhammad Ashraful; Viventi, Jonathan; Aluru, N R; Rogers, John A
2016-10-18
Materials that can serve as long-lived barriers to biofluids are essential to the development of any type of chronic electronic implant. Devices such as cardiac pacemakers and cochlear implants use bulk metal or ceramic packages as hermetic enclosures for the electronics. Emerging classes of flexible, biointegrated electronic systems demand similar levels of isolation from biofluids but with thin, compliant films that can simultaneously serve as biointerfaces for sensing and/or actuation while in contact with the soft, curved, and moving surfaces of target organs. This paper introduces a solution to this materials challenge that combines (i) ultrathin, pristine layers of silicon dioxide (SiO 2 ) thermally grown on device-grade silicon wafers, and (ii) processing schemes that allow integration of these materials onto flexible electronic platforms. Accelerated lifetime tests suggest robust barrier characteristics on timescales that approach 70 y, in layers that are sufficiently thin (less than 1 μm) to avoid significant compromises in mechanical flexibility or in electrical interface fidelity. Detailed studies of temperature- and thickness-dependent electrical and physical properties reveal the key characteristics. Molecular simulations highlight essential aspects of the chemistry that governs interactions between the SiO 2 and surrounding water. Examples of use with passive and active components in high-performance flexible electronic devices suggest broad utility in advanced chronic implants.
Fang, Hui; Yu, Ki Jun; Song, Enming; Farimani, Amir Barati; Chiang, Chia-Han; Jin, Xin; Xu, Dong; Du, Wenbo; Seo, Kyung Jin; Zhong, Yiding; Yang, Zijian; Won, Sang Min; Fang, Guanhua; Choi, Seo Woo; Chaudhuri, Santanu; Huang, Yonggang; Alam, Muhammad Ashraful; Viventi, Jonathan; Aluru, N. R.; Rogers, John A.
2016-01-01
Materials that can serve as long-lived barriers to biofluids are essential to the development of any type of chronic electronic implant. Devices such as cardiac pacemakers and cochlear implants use bulk metal or ceramic packages as hermetic enclosures for the electronics. Emerging classes of flexible, biointegrated electronic systems demand similar levels of isolation from biofluids but with thin, compliant films that can simultaneously serve as biointerfaces for sensing and/or actuation while in contact with the soft, curved, and moving surfaces of target organs. This paper introduces a solution to this materials challenge that combines (i) ultrathin, pristine layers of silicon dioxide (SiO2) thermally grown on device-grade silicon wafers, and (ii) processing schemes that allow integration of these materials onto flexible electronic platforms. Accelerated lifetime tests suggest robust barrier characteristics on timescales that approach 70 y, in layers that are sufficiently thin (less than 1 μm) to avoid significant compromises in mechanical flexibility or in electrical interface fidelity. Detailed studies of temperature- and thickness-dependent electrical and physical properties reveal the key characteristics. Molecular simulations highlight essential aspects of the chemistry that governs interactions between the SiO2 and surrounding water. Examples of use with passive and active components in high-performance flexible electronic devices suggest broad utility in advanced chronic implants. PMID:27791052
Lee, Chen-Jung; Wang, Huifang; Young, Megan; Li, Shengxi; Cheng, Fang; Cong, Hongbo; Cheng, Gang
2018-06-04
Poly(3,4-ethylenedioxythiophene) (PEDOT) has been widely studied in recent decades due to its high stability, biocompatibility, low redox potential, moderate band gap, and optical transparency in its conducting state. However, for its long-term in vivo applications, the biocompatibility of PEDOT still need to be improved. To address this challenge, zwitterionic Poly(sulfobetaine 3,4-ethylenedioxythiophene) (PSBEDOT) that contains EDOT backbone with sulfobetaine functional side chains were developed in our previous study. Although PSBEDOT showed great resistance to proteins, cells, and bacteria, it is still not clear how the zwitterionic sulfobetaine side chain affects the electrochemical properties of the polymer and reactivity of the monomer. To have better understanding on the structure-function relationship of zwitterionic conducting polymer, we synthesized two derivatives of PSBEDOT, PSBEDOT-4 and PSBEDOT-5, by introducing the alkoxyl spacer between EDOT and sulfobetaine. The interfacial impedance of PSBEDOT-4 and PSBEDOT-5 was examined by electrochemical impedance spectroscopy and showed significant improvement which is about 20 times lower than PSBEDOT on both gold and indium tin oxide substrates at 1 Hz. In the protein adsorption test, PSBEDOT, PSBEDOT-4 and PSBEDOT-5 exhibited comparable resistance to the fibrinogen solution. All three polymers had low protein adsorption around 3%-5% comparing to the control sample, PEDOT, which was normalized to 100%. Additionally, the morphology of PSBEDOT, PSBEDOT-4 and PSBEDOT-5 with different synthesis parameter have been investigated by scanning electron microscope. We believe that these stable and biocompatible materials can be good candidates for developing long-term bioelectronics devices. To address the challenges associated existing conducting materials for bioelectronics, we developed a versatile and high performance zwitterionic conducting material platform with excellent stability, electrochemical, antifouling and controllable antimicrobial/antifouling properties. In this work, we developed two high-performance conducting polymers and systematically investigated how its structure affect their properties. Our study shows we can accurately tune the molecular structure of the monomer to dramatically improve the performance of zwitterionic conducting polymer. This zwitterionic conducting polymer platform may dramatically increase the performance and service life of electrochemical devices for many long-term applications, such as implantable biosensing, tissue engineering, wound healing, robotic prostheses, biofuel cell etc., which all require high performance conducting materials with excellent antifouling/biocompatibility at complex biointerfaces. Copyright © 2018. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
Katan, Pesia; Kahta, Shani; Sasson, Ayelet; Schiff, Rachel
2017-01-01
Graph complexity as measured by topological entropy has been previously shown to affect performance on artificial grammar learning tasks among typically developing children. The aim of this study was to examine the effect of graph complexity on implicit sequential learning among children with developmental dyslexia. Our goal was to determine…
Hyperbranched polyglycerols at the biointerface
NASA Astrophysics Data System (ADS)
Moore, Eli; Thissen, Helmut; Voelcker, Nicolas H.
2013-08-01
The control over biointerfacial interactions is the key to a broad range of biomedical applications, ranging from implantable devices to drug delivery and nanomedicine. In many of these applications, coatings are required that reduce or prevent non-specific interactions with the biological environment, while at the same time presenting specific bioactive signals. Whilst surface coatings based on polymers such as poly(ethylene glycol) (PEG) have been used successfully, many limitations persist in regard to the biocompatibility, stability and functionality of state-of-the-art polymer coatings. Most of these limitations are related to the fact that, typically, linear polymers are used with associated limited chemical functionality. Here, we examine the development of hyperbranched polyglycerols (HPGs) as promising candidates for the replacement of traditional linear polymers, such as the chemically analogous PEG, for the control of biointerfacial interactions. HPGs are highly branched globular molecules that exhibit a high valency, allow easy access to a variety of functionalities and can present biologically active signals. In this review, a comprehensive overview is provided with respect to the history, synthetic strategies, modifications and applications of HPGs.
rTMS with Motor Training Modulates Cortico-Basal Ganglia-Thalamocortical Circuits in Stroke Patients
Chang, Won Hyuk; Kim, Yun-Hee; Yoo, Woo-Kyoung; Goo, Kyoung-Hyup; Park, Chang-hyun; Kim, Sung Tae; Pascual-Leone, Alvaro
2013-01-01
Background and Purpose Repetitive transcranial magnetic stimulation (rTMS) may enhance plastic changes in the human cortex and modulation of behavior. However, the underlying neural mechanisms have not been sufficiently investigated. We examined the clinical effects and neural correlates of high-frequency rTMS coupled with motor training in patients with hemiparesis after stroke. Methods Twenty-one patients were randomly divided into two groups, and received either real or sham rTMS. Ten daily sessions of 1,000 pulses of real or sham rTMS were applied at 10 Hz over the primary motor cortex of the affected hemisphere, coupled with sequential finger motor training of the paretic hand. Functional MRIs were obtained before and after training using sequential finger motor tasks, and performances were assessed. Results Following rTMS intervention, movement accuracy of sequential finger motor tasks showed significantly greater improvement in the real group than in the sham group (p<0.05). Real rTMS modulated areas of brain activation during performance of motor tasks with a significant interaction effect in the sensorimotor cortex, thalamus, and caudate nucleus. Patients in the real rTMS group also showed significantly enhanced activation in the affected hemisphere compared to the sham rTMS group. Conclusion According to these results, a 10 day course of high-frequency rTMS coupled with motor training improved motor performance through modulation of activities in the cortico-basal ganglia-thalamocortical circuits. PMID:22555430
Fan, Tingbo; Liu, Zhenbo; Zhang, Dong; Tang, Mengxing
2013-03-01
Lesion formation and temperature distribution induced by high-intensity focused ultrasound (HIFU) were investigated both numerically and experimentally via two energy-delivering strategies, i.e., sequential discrete and continuous scanning modes. Simulations were presented based on the combination of Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation and bioheat equation. Measurements were performed on tissue-mimicking phantoms sonicated by a 1.12-MHz single-element focused transducer working at an acoustic power of 75 W. Both the simulated and experimental results show that, in the sequential discrete mode, obvious saw-tooth-like contours could be observed for the peak temperature distribution and the lesion boundaries, with the increasing interval space between two adjacent exposure points. In the continuous scanning mode, more uniform peak temperature distributions and lesion boundaries would be produced, and the peak temperature values would decrease significantly with the increasing scanning speed. In addition, compared to the sequential discrete mode, the continuous scanning mode could achieve higher treatment efficiency (lesion area generated per second) with a lower peak temperature. The present studies suggest that the peak temperature and tissue lesion resulting from the HIFU exposure could be controlled by adjusting the transducer scanning speed, which is important for improving the HIFU treatment efficiency.
Palmer, Matthew A; Brewer, Neil
2012-06-01
When compared with simultaneous lineup presentation, sequential presentation has been shown to reduce false identifications to a greater extent than it reduces correct identifications. However, there has been much debate about whether this difference in identification performance represents improved discriminability or more conservative responding. In this research, data from 22 experiments that compared sequential and simultaneous lineups were analyzed using a compound signal-detection model, which is specifically designed to describe decision-making performance on tasks such as eyewitness identification tests. Sequential (cf. simultaneous) presentation did not influence discriminability, but produced a conservative shift in response bias that resulted in less-biased choosing for sequential than simultaneous lineups. These results inform understanding of the effects of lineup presentation mode on eyewitness identification decisions.
ERIC Educational Resources Information Center
Sunderman, Gretchen L.; Priya, Kanu
2012-01-01
This study investigates the phonological nature of the lexical links in the bilingual lexicon using different-script bilinguals. Highly proficient Hindi-English bilinguals performed a translation recognition task (i.e., decide whether two words presented sequentially are a correct translation pair). For the critical trials, the second word was a…
NASA Astrophysics Data System (ADS)
Vecchione, Raffaele; Luciani, Giuseppina; Calcagno, Vincenzo; Jakhmola, Anshuman; Silvestri, Brigida; Guarnieri, Daniela; Belli, Valentina; Costantini, Aniello; Netti, Paolo A.
2016-04-01
Stable, biocompatible, multifunctional and multicompartment nanocarriers are much needed in the field of nanomedicine. Here, we report a simple, novel strategy to design an engineered nanocarrier system featuring an oil-core/hybrid polymer/silica-shell. Silica shells with a tunable thickness were grown in situ, directly around a highly mono-disperse and stable oil-in-water emulsion system, stabilized by a double bio-functional polyelectrolyte heparin/chitosan layer. Such silica showed a complete degradation in a physiological medium (SBF) in a time frame of three days. Moreover, the outer silica shell was coated with polyethyleneglycol (PEG) in order to confer antifouling properties to the final nanocapsule. The outer silica layer combined its properties (it is an optimal bio-interface for bio-conjugations and for the embedding of hydrophilic drugs in the porous structure) with the capability to stabilize the oil core for the confinement of high payloads of lipophilic tracers (e.g. CdSe quantum dots, Nile Red) and drugs. In addition, polymer layers - besides conferring stability to the emulsion while building the silica shell - can be independently exploited if suitably functionalized, as demonstrated by conjugating chitosan with fluorescein isothiocyanate. Such numerous features in a single nanocarrier system make it very intriguing as a multifunctional platform for smart diagnosis and therapy.Stable, biocompatible, multifunctional and multicompartment nanocarriers are much needed in the field of nanomedicine. Here, we report a simple, novel strategy to design an engineered nanocarrier system featuring an oil-core/hybrid polymer/silica-shell. Silica shells with a tunable thickness were grown in situ, directly around a highly mono-disperse and stable oil-in-water emulsion system, stabilized by a double bio-functional polyelectrolyte heparin/chitosan layer. Such silica showed a complete degradation in a physiological medium (SBF) in a time frame of three days. Moreover, the outer silica shell was coated with polyethyleneglycol (PEG) in order to confer antifouling properties to the final nanocapsule. The outer silica layer combined its properties (it is an optimal bio-interface for bio-conjugations and for the embedding of hydrophilic drugs in the porous structure) with the capability to stabilize the oil core for the confinement of high payloads of lipophilic tracers (e.g. CdSe quantum dots, Nile Red) and drugs. In addition, polymer layers - besides conferring stability to the emulsion while building the silica shell - can be independently exploited if suitably functionalized, as demonstrated by conjugating chitosan with fluorescein isothiocyanate. Such numerous features in a single nanocarrier system make it very intriguing as a multifunctional platform for smart diagnosis and therapy. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr01192f
Sequential Geoacoustic Filtering and Geoacoustic Inversion
2015-09-30
and online algorithms. We show here that CS obtains higher resolution than MVDR, even in scenarios, which favor classical high-resolution methods...windows actually performs better than conventional beamforming and MVDR/ MUSIC (see Figs. 1-2). Compressive geoacoustic inversion Geoacoustic...histograms based on 100 Monte Carlo simulations, and c)(CS, exhaustive-search, CBF, MVDR, and MUSIC performance versus SNR. The true source positions
Sequential lineups: shift in criterion or decision strategy?
Gronlund, Scott D
2004-04-01
R. C. L. Lindsay and G. L. Wells (1985) argued that a sequential lineup enhanced discriminability because it elicited use of an absolute decision strategy. E. B. Ebbesen and H. D. Flowe (2002) argued that a sequential lineup led witnesses to adopt a more conservative response criterion, thereby affecting bias, not discriminability. Height was encoded as absolute (e.g., 6 ft [1.83 m] tall) or relative (e.g., taller than). If a sequential lineup elicited an absolute decision strategy, the principle of transfer-appropriate processing predicted that performance should be best when height was encoded absolutely. Conversely, if a simultaneous lineup elicited a relative decision strategy, performance should be best when height was encoded relatively. The predicted interaction was observed, providing direct evidence for the decision strategies explanation of what happens when witnesses view a sequential lineup.
Guerrero-Ramos, Alvaro; Patel, Mauli; Kadakia, Kinjal; Haque, Tanzina
2014-06-01
The Architect EBV antibody panel is a new chemiluminescence immunoassay system used to determine the stage of Epstein-Barr virus (EBV) infection based on the detection of IgM and IgG antibodies to viral capsid antigen (VCA) and IgG antibodies against Epstein-Barr nuclear antigen 1 (EBNA-1). We evaluated its diagnostic accuracy in immunocompetent adolescents and young adults with clinical suspicion of infectious mononucleosis (IM) using the RecomLine EBV IgM and IgG immunoblots as the reference standard. In addition, the use of the antibody panel in a sequential testing algorithm based on initial EBNA-1 IgG analysis was assessed for cost-effectiveness. Finally, we investigated the degree of cross-reactivity of the VCA IgM marker during other primary viral infections that may present with an EBV IM-like picture. High sensitivity (98.3% [95% confidence interval {CI}, 90.7 to 99.7%]) and specificity (94.2% [95% CI, 87.9 to 97.8%]) were found after testing 162 precharacterized archived serum samples. There was perfect agreement between the use of the antibody panel in sequential and parallel testing algorithms, but substantial cost savings (23%) were obtained with the sequential strategy. A high rate of reactive VCA IgM results was found in primary cytomegalovirus (CMV) infections (60.7%). In summary, the Architect EBV antibody panel performs satisfactorily in the investigation of EBV IM in immunocompetent adolescents and young adults, and the application of an EBNA-1 IgG-based sequential testing algorithm is cost-effective in this diagnostic setting. Concomitant testing for CMV is strongly recommended to aid in the interpretation of EBV serological patterns. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Patel, Mauli; Kadakia, Kinjal; Haque, Tanzina
2014-01-01
The Architect EBV antibody panel is a new chemiluminescence immunoassay system used to determine the stage of Epstein-Barr virus (EBV) infection based on the detection of IgM and IgG antibodies to viral capsid antigen (VCA) and IgG antibodies against Epstein-Barr nuclear antigen 1 (EBNA-1). We evaluated its diagnostic accuracy in immunocompetent adolescents and young adults with clinical suspicion of infectious mononucleosis (IM) using the RecomLine EBV IgM and IgG immunoblots as the reference standard. In addition, the use of the antibody panel in a sequential testing algorithm based on initial EBNA-1 IgG analysis was assessed for cost-effectiveness. Finally, we investigated the degree of cross-reactivity of the VCA IgM marker during other primary viral infections that may present with an EBV IM-like picture. High sensitivity (98.3% [95% confidence interval {CI}, 90.7 to 99.7%]) and specificity (94.2% [95% CI, 87.9 to 97.8%]) were found after testing 162 precharacterized archived serum samples. There was perfect agreement between the use of the antibody panel in sequential and parallel testing algorithms, but substantial cost savings (23%) were obtained with the sequential strategy. A high rate of reactive VCA IgM results was found in primary cytomegalovirus (CMV) infections (60.7%). In summary, the Architect EBV antibody panel performs satisfactorily in the investigation of EBV IM in immunocompetent adolescents and young adults, and the application of an EBNA-1 IgG-based sequential testing algorithm is cost-effective in this diagnostic setting. Concomitant testing for CMV is strongly recommended to aid in the interpretation of EBV serological patterns. PMID:24695777
NASA Astrophysics Data System (ADS)
Paun, Irina Alexandra; Zamfirescu, Marian; Luculescu, Catalin Romeo; Acasandrei, Adriana Maria; Mustaciosu, Cosmin Catalin; Mihailescu, Mona; Dinescu, Maria
2017-01-01
A major concern in orthopedic implants is to decrease the chronic inflammation using specific drug therapies. The newest strategies rely on the controlled delivery of antiinflammatory drugs from carrier biointerfaces designed in the shape of 3D architectures. We report on electrically responsive microreservoires (ERRs) acting as microcontainers for antiinflammatory drugs, as potential biointerfaces in orthopedic implants. The ERRs consist in arrays of vertical microtubes produced by laser direct writing using two photon polymerization effects (2PP_LDW) of a commercially available photoresist, IP-L780. A polypyrrole (conductive)/dexamethasone (drug model) (PPy/Dex) mixture was loaded into the ERRs via a simple immersion process. Then, the ERRs were sealed with a poly(lactic-co-glycolic acid)(PLGA) layer by Matrix Assisted Pulsed Laser Evaporation. ERRs stimulation using voltage cycles between -1 V and +1 V, applied at specific time intervals, at a scan rate of 0.1 V s-1, enabled to control the Dex release. The release time scales were between 150 and 275 h, while the concentrations of Dex released were between 450-460 nM after three applied voltage cycles, for different microreservoires dimensions. The proposed approach was validated in osteoblast-like MG-63 cell cultures. Cell viability and adhesion assays showed that the Dex-loaded ERRs sustained the cells growth and preserved their characteristic polygonal shape. Importantly, for the electrically-stimulated Dex release, the level of the alkaline phosphatase activity increased twice, the osteogenic differentiation surpassed by 1.6 times and the relative level of osteocalcin gene expression was 2.2 times higher as compared with the unstimulated drug release. Overall, the ERRs were able to accelerate the cells osteogenic differentiation via electrically controlled release of Dex.
Härkönen, Kati; Kivekäs, Ilkka; Rautiainen, Markus; Kotti, Voitto; Sivonen, Ville; Vasama, Juha-Pekka
2015-05-01
This prospective study shows that working performance, quality of life (QoL), and quality of hearing (QoH) are better with two compared with a single cochlear implant (CI). The impact of the second CI on the patient's QoL is as significant as the impact of the first CI. To evaluate the benefits of sequential bilateral cochlear implantation in working, QoL, and QoH. We studied working performance, work-related stress, QoL, and QoH with specific questionnaires in 15 patients with unilateral CI scheduled for sequential CI of another ear. Sound localization performance and speech perception in noise were measured with specific tests. All questionnaires and tests were performed before the second CI surgery and 6 and 12 months after its activation. Bilateral CIs increased patients' working performance and their work-related stress and fatigue decreased. Communication with co-workers was easier and patients were more active in their working environment. Sequential bilateral cochlear implantation improved QoL, QoH, sound localization, and speech perception in noise statistically significantly.
Bio-functionalized graphene–graphene oxide nanocomposite based electrochemical immunosensing
Sharma, Priyanka; Tuteja, Satish K.; Bhalla, Vijayender; Shekhawat, G.; Dravid, Vinayak P.; Suri, C.Raman
2014-01-01
We report a novel in-situ electrochemical synthesis approach for the formation of functionalized graphene–graphene oxide (fG–GO) nanocomposite on screen-printed electrodes (SPE). Electrochemically controlled nanocomposite film formation was studied by transmission electron microscopy (TEM) and Raman spectroscopy. Further insight into the nanocomposite has been accomplished by the Fourier transformed infrared spectroscopy (FTIR), thermal gravimetric analysis (TGA) and X-ray diffraction (XRD) spectroscopy. Configured as a highly responsive screen-printed immunosensor, the fG–GO nanocomposite on SPE exhibits electrical and chemical synergies of the nano-hybrid functional construct by combining good electronic properties of functionalized graphene (fG) and the facile chemical functionality of graphene oxide (GO) for compatible bio-interface development using specific anti-diuron antibody. The enhanced electrical properties of nanocomposite biofilm demonstrated a significant increase in electrochemical signal response in a competitive inhibition immunoassay format for diuron detection, promising its potential applicability for ultra-sensitive detection of range of target analytes. PMID:22884654
[Application of selection criteria in sequential double lung transplantation].
Borro, J M; Tarazona, V; Vicente, R; Cafarena, J M; Ramos, F; Sales, G; Galán, G; Lozano, C; Morant, P; Calvo, V; Morcillo, A; París, F
1999-03-01
Since the first sequential double lung transplant was performed in 1986, such procedures have been increasing in number and the criteria used as indications for this type of surgery have broadened. Our aim was to reflect on the application of selection criteria and to describe the anesthetic and surgical techniques and postoperative follow-up of 72 patients who underwent this type of transplant surgery between March 1993 and December 1998. Actuarial survival five years after surgery was 74.4%. Among patients requiring transplantation after septic disease, actuarial survival was 90.8% for cystic fibrosis and 88.2% for bronchiectasis. Of the preoperative risk factors analyzed (prior surgery, pachypleuritis, multiresistant germs, poor nutrition, mechanical ventilation and corticoid therapy), only prior treatment with high doses of corticoids proved significant. Eleven patients have been diagnosed of bronchiolitis obliterans, four have died and only two continue to experience difficulties in daily living. The high survival rate and the restriction-free life after recovery lead us to consider sequential double lung transplantation to be the treatment of choice for all pulmonary diseases.
Liu, Huawei; Li, Baoqing; Yuan, Xiaobing; Zhou, Qianwei; Huang, Jingchang
2018-03-27
Parameters estimation of sequential movement events of vehicles is facing the challenges of noise interferences and the demands of portable implementation. In this paper, we propose a robust direction-of-arrival (DOA) estimation method for the sequential movement events of vehicles based on a small Micro-Electro-Mechanical System (MEMS) microphone array system. Inspired by the incoherent signal-subspace method (ISM), the method that is proposed in this work employs multiple sub-bands, which are selected from the wideband signals with high magnitude-squared coherence to track moving vehicles in the presence of wind noise. The field test results demonstrate that the proposed method has a better performance in emulating the DOA of a moving vehicle even in the case of severe wind interference than the narrowband multiple signal classification (MUSIC) method, the sub-band DOA estimation method, and the classical two-sided correlation transformation (TCT) method.
Crespi, Ilaria; Sulas, Maria Giovanna; Mora, Riccardo; Naldi, Paola; Vecchio, Domizia; Comi, Cristoforo; Cantello, Roberto; Bellomo, Giorgio
2017-03-01
Isoelectrofocusing (IEF) to detect oligoclonal bands (OBCs) in cerebrospinal fluid (CSF) is the gold standard approach for evaluating intrathecal immunoglobulin synthesis in multiple sclerosis (MS) but the kappa free light chain index (KFLCi) is emerging as an alternative marker, and the combined/sequential uses of IEF and KFLCi have never been challenged. CSF and serum albumin, IgG, kFLC and lFLC were measured by nephelometry; albumin, IgG and kFLC quotients as well as Link and kFLC indexes were calculated; OCBs were evaluated by immunofixation. A total of 150 consecutive patients: 48 with MS, 32 with other neurological inflammatory diseases (NID), 62 with neurological non-inflammatory diseases (NNID), and 8 without any detectable neurological disease (NND) were investigated. Both IEF and KFLCi showed a similar accuracy as diagnostic tests for multiple sclerosis. The high sensitivity and specificity associated with the lower cost of KFLCi suggested to use this test first, followed by IEF as a confirmative procedure. The sequential use of IEF and KFLCi showed high diagnostic efficiency with cost reduction of 43 and 21%, if compared to the contemporary use of both tests, or the unique use of IEF in all patients. The "sequential testing" using KFLCi followed by IEF in MS represents an optimal procedure with accurate performance and lower costs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowder, M.A.; Sposili, R.S.; Cho, H.S.
Nonhydrogenated, n-channel, low-temperature-processed, single-crystal Si thin-film transistors (TFT`s) have been fabricated on Si thin films prepared via sequential lateral solidification (SLS). The device characteristics of the resulting SLS TFT`s exhibit properties and a level of performance that are superior to polycrystalline Si-based TFT`s and are comparable to similar devices fabricated on silicon-on-insulator (SOI) substrates or bulk-Si wafers. The authors attribute these high-performance device characteristics to the absence of high-angle grain-boundaries within the active channel portion of the TFT`s.
High-contrast coronagraph performance in the presence of focal plane mask defects
NASA Astrophysics Data System (ADS)
Sidick, Erkin; Shaklan, Stuart; Balasubramanian, Kunjithapatham; Cady, Eric
2014-08-01
We have carried out a study of the performance of high-contrast coronagraphs in the presence of mask defects. We have considered the effects of opaque and dielectric particles of various dimensions, as well as systematic mask fabrication errors and the limitations of material properties in creating dark holes. We employ sequential deformable mirrors to compensate for phase and amplitude errors, and show the limitations of this approach in the presence of coronagraph image-mask defects.
López-Pelayo, Iratxe; Gutiérrez-Romero, Javier María; Armada, Ana Isabel Mangano; Calero-Ruiz, María Mercedes; Acevedo-Yagüe, Pablo Javier Moreno de
2018-04-26
To compare embryo quality, fertilization, implantation, miscarriage and clinical pregnancy rates for embryos cultured in two different commercial culture media until D-2 or D-3. In this retrospective study, we analyzed 189 cycles performed in 2016. Metaphase II oocytes were microinjected and allocated into single medium (SAGE 1-STEP, Origio) until transferred, frozen or discarded; or, if sequential media were used, the oocytes were cultured in G1-PLUSTM (Vitrolife) up to D-2 or D-3 and in G2-PLUSTM (Vitrolife) to transfer. On the following day, the oocytes were checked for normal fertilization and on D-2 and D-3 for morphological classification. Statistical analysis was performed using the chi-square and Mann-Whitney tests in PASW Statistics 18.0. The fertilization rates were 70.07% for single and 69.11% for sequential media (p=0.736). The mean number of embryos with high morphological quality (class A/B) was higher in the single medium than in the sequential media: D-2 [class A (190 vs. 107, p<0.001), B (133 vs. 118, p=0.018)]; D-3 [class A (40 vs. 19, p=0.048) but without differences in class B (40 vs. 49)]. Consequently, a higher number of embryos cultured in single medium were frozen: 197 (21.00%) vs. sequential: 102 (11.00%), p<0.001. No differences were found in implantation rates (30.16% vs. 25.57%, p=0.520), clinical pregnancy rates (55.88% vs. 41.05%, p=0.213), or miscarriage rates (14.29% vs. 9.52%, p=0.472). Embryo culture in single medium yields greater efficiency per cycle than in sequential media. Higher embryo quality and quantity were achieved, resulting in more frozen embryos. There were no differences in clinical pregnancy rates.
Bioinspired Zwitterionic Surface Coatings with Robust Photostability and Fouling Resistance.
Huang, Chun-Jen; Chu, Sz-Hau; Wang, Lin-Chuan; Li, Chien-Hung; Lee, T Randall
2015-10-28
Great care has been paid to the biointerface between a bulk material and the biological environment, which plays a key role in the optimized performance of medical devices. In this work, we report a new superhydrophilic adsorbate, called L-cysteine betaine (Cys-b), having branched zwitterionic groups that give rise to surfaces and nanoparticles with enhanced chemical stability, biofouling resistance, and inertness to environmental changes. Cys-b was synthesized from the amphoteric sulfur-containing amino acid, L-cysteine (Cys), by quaternization of its amino group. Gold surfaces modified with Cys-b exhibited prominent repellence against the nonspecific adsorption of proteins, bacteria, and fibroblast cells. In addition, Cys-b existed in zwitterionic form over a wide pH range (i.e., pH 3.4 to 10.8), and showed excellent suppression in photoinduced oxidation on gold substrates. Furthermore, the modification of hollow Ag@Au nanoshells with Cys-b gave rise to nanoparticles with excellent colloidal stability and resistance to coordinative interaction with Cu(2+). Taken together, the unique features of Cys-b offer a new nanoscale coating for use in a wide spectrum of applications.
Sequential capture of CO2 and SO2 in a pressurized TGA simulating FBC conditions.
Sun, Ping; Grace, John R; Lim, C Jim; Anthony, Edward J
2007-04-15
Four FBC-based processes were investigated as possible means of sequentially capturing SO2 and CO2. Sorbent performance is the key to their technical feasibility. Two sorbents (a limestone and a dolomite) were tested in a pressurized thermogravimetric analyzer (PTGA). The sorbent behaviors were explained based on complex interaction between carbonation, sulfation, and direct sulfation. The best option involved using limestone or dolomite as a SO2-sorbent in a FBC combustor following cyclic CO2 capture. Highly sintered limestone is a good sorbent for SO2 because of the generation of macropores during calcination/carbonation cycling.
Students' conceptual performance on synthesis physics problems with varying mathematical complexity
NASA Astrophysics Data System (ADS)
Ibrahim, Bashirah; Ding, Lin; Heckler, Andrew F.; White, Daniel R.; Badeau, Ryan
2017-06-01
A body of research on physics problem solving has focused on single-concept problems. In this study we use "synthesis problems" that involve multiple concepts typically taught in different chapters. We use two types of synthesis problems, sequential and simultaneous synthesis tasks. Sequential problems require a consecutive application of fundamental principles, and simultaneous problems require a concurrent application of pertinent concepts. We explore students' conceptual performance when they solve quantitative synthesis problems with varying mathematical complexity. Conceptual performance refers to the identification, follow-up, and correct application of the pertinent concepts. Mathematical complexity is determined by the type and the number of equations to be manipulated concurrently due to the number of unknowns in each equation. Data were collected from written tasks and individual interviews administered to physics major students (N =179 ) enrolled in a second year mechanics course. The results indicate that mathematical complexity does not impact students' conceptual performance on the sequential tasks. In contrast, for the simultaneous problems, mathematical complexity negatively influences the students' conceptual performance. This difference may be explained by the students' familiarity with and confidence in particular concepts coupled with cognitive load associated with manipulating complex quantitative equations. Another explanation pertains to the type of synthesis problems, either sequential or simultaneous task. The students split the situation presented in the sequential synthesis tasks into segments but treated the situation in the simultaneous synthesis tasks as a single event.
Algorithms and Application of Sparse Matrix Assembly and Equation Solvers for Aeroacoustics
NASA Technical Reports Server (NTRS)
Watson, W. R.; Nguyen, D. T.; Reddy, C. J.; Vatsa, V. N.; Tang, W. H.
2001-01-01
An algorithm for symmetric sparse equation solutions on an unstructured grid is described. Efficient, sequential sparse algorithms for degree-of-freedom reordering, supernodes, symbolic/numerical factorization, and forward backward solution phases are reviewed. Three sparse algorithms for the generation and assembly of symmetric systems of matrix equations are presented. The accuracy and numerical performance of the sequential version of the sparse algorithms are evaluated over the frequency range of interest in a three-dimensional aeroacoustics application. Results show that the solver solutions are accurate using a discretization of 12 points per wavelength. Results also show that the first assembly algorithm is impractical for high-frequency noise calculations. The second and third assembly algorithms have nearly equal performance at low values of source frequencies, but at higher values of source frequencies the third algorithm saves CPU time and RAM. The CPU time and the RAM required by the second and third assembly algorithms are two orders of magnitude smaller than that required by the sparse equation solver. A sequential version of these sparse algorithms can, therefore, be conveniently incorporated into a substructuring for domain decomposition formulation to achieve parallel computation, where different substructures are handles by different parallel processors.
Multiuser signal detection using sequential decoding
NASA Astrophysics Data System (ADS)
Xie, Zhenhua; Rushforth, Craig K.; Short, Robert T.
1990-05-01
The application of sequential decoding to the detection of data transmitted over the additive white Gaussian noise channel by K asynchronous transmitters using direct-sequence spread-spectrum multiple access is considered. A modification of Fano's (1963) sequential-decoding metric, allowing the messages from a given user to be safely decoded if its Eb/N0 exceeds -1.6 dB, is presented. Computer simulation is used to evaluate the performance of a sequential decoder that uses this metric in conjunction with the stack algorithm. In many circumstances, the sequential decoder achieves results comparable to those obtained using the much more complicated optimal receiver.
SR high-speed K-edge subtraction angiography in the small animal (abstract)
NASA Astrophysics Data System (ADS)
Takeda, T.; Akisada, M.; Nakajima, T.; Anno, I.; Ueda, K.; Umetani, K.; Yamaguchi, C.
1989-07-01
To assess the ability of the high-speed K-edge energy subtraction system which was made at beamline 8C of Photon Factory, Tsukuba, we performed an animal experiment. Rabbits were used for the intravenous K-edge subtraction angiography. In this paper, the actual images of the artery obtained by this system, are demonstrated. The high-speed K-edge subtraction system consisted of movable silicon (111) monocrystals, II-ITV, and digital memory system. Image processing was performed by 68000-IP computer. The monochromatic x-ray beam size was 50×60 mm. Photon energy above and below iodine K edge was changed within 16 ms and 32 frames of images were obtained sequentially. The rabbits were anaesthetized by phenobarbital and a 5F catheter was inserted into inferior vena cava via the femoral vein. 1.5 ml/kg of contrast material (Conlaxin H) was injected at the rate of 0.5 ml/kg/s. TV images were obtained 3 s after the starting point of injection. By using this system, the clear K-edge subtracted images were obtained sequentially as a conventional DSA system. The quality of the images were better than that obtained by DSA. The dynamical blood flow was analyzed, and the best arterial image could be selected from the sequential images. The structures of aortic arch, common carotid arteries, right subclavian artery, and internal thoracic artery were obtained at the chest. Both common carotid arteries and vertebral arteries were recorded at the neck. The diameter of about 0.3-0.4 mm artery could be clearly revealed. The high-speed K-edge subtraction system demonstrates the very sharp arterial images clearly and dynamically.
Control of Task Sequences: What Is the Role of Language?
ERIC Educational Resources Information Center
Mayr, Ulrich; Kleffner-Canucci, Killian; Kikumoto, Atsushi; Redford, Melissa A.
2014-01-01
It is almost a truism that language aids serial-order control through self-cuing of upcoming sequential elements. We measured speech onset latencies as subjects performed hierarchically organized task sequences while "thinking aloud" each task label. Surprisingly, speech onset latencies and response times (RTs) were highly synchronized,…
Sequential growth for lifetime extension in biomimetic polypyrrole actuator systems
NASA Astrophysics Data System (ADS)
Sarrazin, J. C.; Mascaro, Stephen A.
2015-04-01
Electroactive polymers (EAPs) present prospective use in actuation and manipulation devices due to their low electrical activation requirements, biocompatibility, and mechanical performance. One of the main drawbacks with EAP actuators is a decrease in performance over extended periods of operation caused by over-oxidation of the polymer and general polymer degradation. Synthesis of the EAP material, polypyrrole with an embedded metal helix allows for sequential growth of the polymer during operation. The helical metal electrode acts as a scaffolding to support the polymer, and direct the 3-dimensional change in volume of the polymer along the axis of the helix during oxidative and reductive cycling. The metal helix also provides a working metal electrode through the entire length of the polymer actuator to distribute charge for actuation, as well as for sequential growth steps during the lifetime of operation of the polymer. This work demonstrates the method of sequential growth can be utilized after extended periods of use to partially restore electrical and mechanical performance of polypyrrole actuators. Since the actuation must be temporarily stopped to allow for a sequential growth cycle to be performed and reverse some of the polymer degradation, these actuator systems more closely mimic natural muscle in their analogous maintenance and repair.
Molecular Design of Antifouling Polymer Brushes Using Sequence-Specific Peptoids
Lau, King Hang Aaron; Sileika, Tadas S.; Park, Sung Hyun; ...
2014-11-26
Material systems that can be used to flexibly and precisely define the chemical nature and molecular arrangement of a surface would be invaluable for the control of complex biointerfacial interactions. For example, progress in antifouling polymer biointerfaces that prevents nonspecific protein adsorption and cell attachment, which can significantly improve the performance of an array of biomedical and industrial applications, is hampered by a lack of chemical models to identify the molecular features conferring their properties. Poly(N-substituted glycine) “peptoids” are peptidomimetic polymers that can be conveniently synthesized with specific monomer sequences and chain lengths, and are presented as a versatile platformmore » for investigating the molecular design of antifouling polymer brushes. Zwitterionic antifouling polymer brushes have captured significant recent attention, and a targeted library of zwitterionic peptoid brushes with different charge densities, hydration, separations between charged groups, chain lengths, and grafted chain densities, is quantitatively evaluated for their antifouling properties through a range of protein adsorption and cell attachment assays. Specific zwitterionic brush designs are found to give rise to distinct but subtle differences in properties. In conclusion, the results also point to the dominant roles of the grafted chain density and chain length in determining the performance of antifouling polymer brushes.« less
Grover, Elise; Hossain, Mohammed Kamal; Uddin, Saker; Venkatesh, Mohini; Ram, Pavani K; Dreibelbis, Robert
2018-01-01
To determine the impact of environmental nudges on handwashing behaviours among primary school children as compared to a high-intensity hygiene education intervention. In a cluster-randomised trial (CRT), we compared the rates of handwashing with soap (HWWS) after a toileting event among primary school students in rural Bangladesh. Eligible schools (government run, on-site sanitation and water, no hygiene interventions in last year, fewer than 450 students) were identified, and 20 schools were randomly selected and allocated without blinding to one of four interventions, five schools per group: simultaneous handwashing infrastructure and nudge construction, sequential infrastructure then nudge construction, simultaneous infrastructure and high-intensity hygiene education (HE) and sequential handwashing infrastructure and HE. The primary outcome, incidence of HWWS after a toileting event, was compared between the intervention groups at different data collection points with robust-Poisson regression analysis with generalised estimating equations, adjusting for school-level clustering of outcomes. The nudge intervention and the HE intervention were found to be equally effective at sustained impact over 5 months post-intervention (adjusted IRR 0.81, 95% CI 0.61-1.09). When comparing intervention delivery timing, the simultaneous delivery of the HE intervention significantly outperformed the sequential HE delivery (adjusted IRR 1.58 CI 1.20-2.08), whereas no significant difference was observed between sequential and simultaneous nudge intervention delivery (adjusted IRR 0.75, 95% CI 0.48-1.17). Our trial demonstrates sustained improved handwashing behaviour 5 months after the nudge intervention. The nudge intervention's comparable performance to a high-intensity hygiene education intervention is encouraging. © 2017 John Wiley & Sons Ltd.
A fast and accurate online sequential learning algorithm for feedforward networks.
Liang, Nan-Ying; Huang, Guang-Bin; Saratchandran, P; Sundararajan, N
2006-11-01
In this paper, we develop an online sequential learning algorithm for single hidden layer feedforward networks (SLFNs) with additive or radial basis function (RBF) hidden nodes in a unified framework. The algorithm is referred to as online sequential extreme learning machine (OS-ELM) and can learn data one-by-one or chunk-by-chunk (a block of data) with fixed or varying chunk size. The activation functions for additive nodes in OS-ELM can be any bounded nonconstant piecewise continuous functions and the activation functions for RBF nodes can be any integrable piecewise continuous functions. In OS-ELM, the parameters of hidden nodes (the input weights and biases of additive nodes or the centers and impact factors of RBF nodes) are randomly selected and the output weights are analytically determined based on the sequentially arriving data. The algorithm uses the ideas of ELM of Huang et al. developed for batch learning which has been shown to be extremely fast with generalization performance better than other batch training methods. Apart from selecting the number of hidden nodes, no other control parameters have to be manually chosen. Detailed performance comparison of OS-ELM is done with other popular sequential learning algorithms on benchmark problems drawn from the regression, classification and time series prediction areas. The results show that the OS-ELM is faster than the other sequential algorithms and produces better generalization performance.
Satínský, Dalibor; Huclová, Jitka; Ferreira, Raquel L C; Montenegro, Maria Conceição B S M; Solich, Petr
2006-02-13
The porous monolithic columns show high performance at relatively low pressure. The coupling of short monoliths with sequential injection technique (SIA) results in a new approach to implementation of separation step to non-separation low-pressure method. In this contribution, a new separation method for simultaneous determination of ambroxol, methylparaben and benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith SpeedROD RP-18e, 50-4.6 mm column with 10 mm precolumn and a FIAlab 3000 system with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-tetrahydrofuran-0.05M acetic acid (10:10:90, v/v/v), pH 3.75 adjusted with triethylamine, flow rate 0.48 mlmin(-1), UV-detection was at 245 nm. The analysis time was <11 min. A new SIC method was validated and compared with HPLC. The method was found to be useful for the routine analysis of the active compounds ambroxol and preservatives (methylparaben or benzoic acid) in various pharmaceutical syrups and drops.
Zonnevijlle, Erik D H; Perez-Abadia, Gustavo; Stremel, Richard W; Maldonado, Claudio J; Kon, Moshe; Barker, John H
2003-11-01
Muscle tissue transplantation applied to regain or dynamically assist contractile functions is known as 'dynamic myoplasty'. Success rates of clinical applications are unpredictable, because of lack of endurance, ischemic lesions, abundant scar formation and inadequate performance of tasks due to lack of refined control. Electrical stimulation is used to control dynamic myoplasties and should be improved to reduce some of these drawbacks. Sequential segmental neuromuscular stimulation improves the endurance and closed-loop control offers refinement in rate of contraction of the muscle, while function-controlling stimulator algorithms present the possibility of performing more complex tasks. An acute feasibility study was performed in anaesthetised dogs combining these techniques. Electrically stimulated gracilis-based neo-sphincters were compared to native sphincters with regard to their ability to maintain continence. Measurements were made during fast bladder pressure changes, static high bladder pressure and slow filling of the bladder, mimicking among others posture changes, lifting heavy objects and diuresis. In general, neo-sphincter and native sphincter performance showed no significant difference during these measurements. However, during high bladder pressures reaching 40 cm H(2)O the neo-sphincters maintained positive pressure gradients, whereas most native sphincters relaxed. During slow filling of the bladder the neo-sphincters maintained a controlled positive pressure gradient for a prolonged time without any form of training. Furthermore, the accuracy of these maintained pressure gradients proved to be within the limits set up by the native sphincters. Refinements using more complicated self-learning function-controlling algorithms proved to be effective also and are briefly discussed. In conclusion, a combination of sequential stimulation, closed-loop control and function-controlling algorithms proved feasible in this dynamic graciloplasty-model. Neo-sphincters were created, which would probably provide an acceptable performance, when the stimulation system could be implanted and further tested. Sizing this technique down to implantable proportions seems to be justified and will enable exploration of the possible benefits.
Bahnasy, Mahmoud F; Lucy, Charles A
2012-12-07
A sequential surfactant bilayer/diblock copolymer coating was previously developed for the separation of proteins. The coating is formed by flushing the capillary with the cationic surfactant dioctadecyldimethylammonium bromide (DODAB) followed by the neutral polymer poly-oxyethylene (POE) stearate. Herein we show the method development and optimization for capillary isoelectric focusing (cIEF) separations based on the developed sequential coating. Electroosmotic flow can be tuned by varying the POE chain length which allows optimization of resolution and analysis time. DODAB/POE 40 stearate can be used to perform single-step cIEF, while both DODAB/POE 40 and DODAB/POE 100 stearate allow performing two-step cIEF methodologies. A set of peptide markers is used to assess the coating performance. The sequential coating has been applied successfully to cIEF separations using different capillary lengths and inner diameters. A linear pH gradient is established only in two-step CIEF methodology using 3-10 pH 2.5% (v/v) carrier ampholyte. Hemoglobin A(0) and S variants are successfully resolved on DODAB/POE 40 stearate sequentially coated capillaries. Copyright © 2012 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Reeder, Ruth M.; Firszt, Jill B.; Holden, Laura K.; Strube, Michael J.
2014-01-01
Purpose: The purpose of this study was to examine the rate of progress in the 2nd implanted ear as it relates to the 1st implanted ear and to bilateral performance in adult sequential cochlear implant recipients. In addition, this study aimed to identify factors that contribute to patient outcomes. Method: The authors performed a prospective…
Real-time simultaneous and proportional myoelectric control using intramuscular EMG
Kuiken, Todd A; Hargrove, Levi J
2014-01-01
Objective Myoelectric prostheses use electromyographic (EMG) signals to control movement of prosthetic joints. Clinically available myoelectric control strategies do not allow simultaneous movement of multiple degrees of freedom (DOFs); however, the use of implantable devices that record intramuscular EMG signals could overcome this constraint. The objective of this study was to evaluate the real-time simultaneous control of three DOFs (wrist rotation, wrist flexion/extension, and hand open/close) using intramuscular EMG. Approach We evaluated task performance of five able-bodied subjects in a virtual environment using two control strategies with fine-wire EMG: (i) parallel dual-site differential control, which enabled simultaneous control of three DOFs and (ii) pattern recognition control, which required sequential control of DOFs. Main Results Over the course of the experiment, subjects using parallel dual-site control demonstrated increased use of simultaneous control and improved performance in a Fitts' Law test. By the end of the experiment, performance using parallel dual-site control was significantly better (up to a 25% increase in throughput) than when using sequential pattern recognition control for tasks requiring multiple DOFs. The learning trends with parallel dual-site control suggested that further improvements in performance metrics were possible. Subjects occasionally experienced difficulty in performing isolated single-DOF movements with parallel dual-site control but were able to accomplish related Fitts' Law tasks with high levels of path efficiency. Significance These results suggest that intramuscular EMG, used in a parallel dual-site configuration, can provide simultaneous control of a multi-DOF prosthetic wrist and hand and may outperform current methods that enforce sequential control. PMID:25394366
Real-time simultaneous and proportional myoelectric control using intramuscular EMG
NASA Astrophysics Data System (ADS)
Smith, Lauren H.; Kuiken, Todd A.; Hargrove, Levi J.
2014-12-01
Objective. Myoelectric prostheses use electromyographic (EMG) signals to control movement of prosthetic joints. Clinically available myoelectric control strategies do not allow simultaneous movement of multiple degrees of freedom (DOFs); however, the use of implantable devices that record intramuscular EMG signals could overcome this constraint. The objective of this study was to evaluate the real-time simultaneous control of three DOFs (wrist rotation, wrist flexion/extension, and hand open/close) using intramuscular EMG. Approach. We evaluated task performance of five able-bodied subjects in a virtual environment using two control strategies with fine-wire EMG: (i) parallel dual-site differential control, which enabled simultaneous control of three DOFs and (ii) pattern recognition control, which required sequential control of DOFs. Main results. Over the course of the experiment, subjects using parallel dual-site control demonstrated increased use of simultaneous control and improved performance in a Fitts’ Law test. By the end of the experiment, performance using parallel dual-site control was significantly better (up to a 25% increase in throughput) than when using sequential pattern recognition control for tasks requiring multiple DOFs. The learning trends with parallel dual-site control suggested that further improvements in performance metrics were possible. Subjects occasionally experienced difficulty in performing isolated single-DOF movements with parallel dual-site control but were able to accomplish related Fitts’ Law tasks with high levels of path efficiency. Significance. These results suggest that intramuscular EMG, used in a parallel dual-site configuration, can provide simultaneous control of a multi-DOF prosthetic wrist and hand and may outperform current methods that enforce sequential control.
NASA Astrophysics Data System (ADS)
Lopez, Juan Manuel
Layer-by-layer self-assembly (LbL) is a technique that generates engineered nano-scale films, coatings, and particles. These nanoscale films have recently been used in multiple biomedical applications. Concurrently, microfabrication methods and advances in microfluidics are being developed and combined to create "Lab-on-a-Chip" technologies. The potential to perform complex biological assays in vitro as a first-line screening technique before moving on to animal models has made the concept of lab on a chip a valuable research tool. Prior studies in the Biofluids Laboratory at Louisiana Tech have used layer-by-layer and in vitro biological assays to study thrombogenesis in a controlled, repeatable, engineered environment. The reliability of these previously established techniques was unsatisfactory for more complex cases such as chemical and shear stress interactions. The work presented in this dissertation was performed to test the principal assumptions behind the established laboratory methodologies, suggest improvements where needed, and test the impact of these improvements on accuracy and repeatability. The assumptions to be tested were: (1) The fluorescence microscopy (FM) images of acridine orange-tagged platelets accurately provide a measure of percent area of surface covered by platelets; (2) fibrinogen coatings can be accurately controlled, interact with platelets, and do not interfere with the ability to quantify platelet adhesion; and (3) the dependence of platelet adhesion on chemical agents, as measured with the modified methods, generally agrees with results obtained from our previous methods and with known responses of platelets that have been documented in the literature. The distribution of fibrinogen on the final LbL surface generated with the standard, static process (s-LbL) was imaged by tagging the fibrinogen with an anti-fibrinogen antibody bound to fluorescein isothiocyanate (FITC). FITC FM images and acridine orange FM images were taken sequentially at selected surface locations to generate a composite overlap of presumed platelet adhesion as a function of fibrinogen distribution. The method was unable to distinguish the surface from the adhered cells. The surface inhomogeneity and porosity retained a large amount of acridine orange stain, even in the absence of platelets, and components in the platelet-rich plasma (PRP) were found to fix acridine orange in a mode that fluoresced in the FITC imaging FM. Both of these problems obfuscated the platelet adhesion FM results when using s-LbL surfaces and acridine orange staining of platelets. A dynamic process (d-LbL) was developed in which a solution of the molecule to be layered was constantly washed over the surface, and was constantly mixed to maintain a more homogeneous distribution of solute relative to the surface during the layering process. The d-LbL surfaces were tested as described above, and found to reduce the size and number of regions of anomalous acridine orange pooling trapped by the surface, providing a greater consistency and reliability in identifying platelets. The improved surface was then used in a series of platelet adhesion experiments under static and dynamic flow conditions, and with and without the chemical additive L-arginine. The complex microcharmel system used in prior studies was replaced with a simpler system involving fewer nuisance variables for these tests. The tests were performed on both collagen and fibrinogen surfaces. Collagen has been used as a thrombogenic surface in multiple studies in the literature, but produces additional variables in thrombogenesis control that are avoided when fibrinogen is used. In these tests, fibrinogen was found to be as thrombogenic as collagen, and platelet coverage of both biointerfaces was reduced by L-arginine in a manner similar to previously reported work. The simpler system differed from the previous microchannel system in important factors: (1) It exposed the platelets to much lower shear stresses; (2) It introduced an oscillatory flow, which introduced a higher degree of variability in the adhesion than previously reported; (3) the previous work had not removed the acridine orange surface problems. Therefore, a direct comparison between results was not possible. The new d-LbL surface process was successful in testing the basic assumptions. Testing showed that the new process eliminated the anomalous acridine orange retention problem during fluorescence imaging. This improvement in fluorescence response meant that the FM results matched the platelet adhesion on plain glass slides and adhesion reported by others in microfluidic flows. The chemical additive responses behaved as expected, with an increase in L-arginine contributing to a decrease in thrombogenesis under dynamic conditions, but not under static conditions.
Surface Plasmon Resonance: New Biointerface Designs and High-Throughput Affinity Screening
NASA Astrophysics Data System (ADS)
Linman, Matthew J.; Cheng, Quan Jason
Surface plasmon resonance (SPR) is a surface optical technique that measures minute changes in refractive index at a metal-coated surface. It has become increasingly popular in the study of biological and chemical analytes because of its label-free measurement feature. In addition, SPR allows for both quantitative and qualitative assessment of binding interactions in real time, making it ideally suited for probing weak interactions that are often difficult to study with other methods. This chapter presents the biosensor development in the last 3 years or so utilizing SPR as the principal analytical technique, along with a concise background of the technique itself. While SPR has demonstrated many advantages, it is a nonselective method and so, building reproducible and functional interfaces is vital to sensing applications. This chapter, therefore, focuses mainly on unique surface chemistries and assay approaches to examine biological interactions with SPR. In addition, SPR imaging for high-throughput screening based on microarrays and novel hyphenated techniques involving the coupling of SPR to other analytical methods is discussed. The chapter concludes with a commentary on the current state of SPR biosensing technology and the general direction of future biosensor research.
ERIC Educational Resources Information Center
Ram-Tsur, Ronit; Faust, Miriam; Zivotofsky, Ari Z.
2008-01-01
The present study investigates the performance of persons with reading disabilities (PRD) on a variety of sequential visual-comparison tasks that have different working-memory requirements. In addition, mediating relationships between the sequential comparison process and attention and memory skills were looked for. Our findings suggest that PRD…
Decay modes of the Hoyle state in 12C
NASA Astrophysics Data System (ADS)
Zheng, H.; Bonasera, A.; Huang, M.; Zhang, S.
2018-04-01
Recent experimental results give an upper limit less than 0.043% (95% C.L.) to the direct decay of the Hoyle state into 3α respect to the sequential decay into 8Be + α. We performed one and two-dimensional tunneling calculations to estimate such a ratio and found it to be more than one order of magnitude smaller than experiment depending on the range of the nuclear force. This is within high statistics experimental capabilities. Our results can also be tested by measuring the decay modes of high excitation energy states of 12C where the ratio of direct to sequential decay might reach 10% at E*(12C) = 10.3 MeV. The link between a Bose Einstein Condensate (BEC) and the direct decay of the Hoyle state is also addressed. We discuss a hypothetical 'Efimov state' at E*(12C) = 7.458 MeV, which would mainly sequentially decay with 3α of equal energies: a counterintuitive result of tunneling. Such a state, if it would exist, is at least 8 orders of magnitude less probable than the Hoyle's, thus below the sensitivity of recent and past experiments.
Sequential and simultaneous thermal and particle exposure of tungsten
NASA Astrophysics Data System (ADS)
Steudel, I.; Huber, A.; Kreter, A.; Linke, J.; Sergienko, G.; Unterberg, B.; Wirtz, M.
2016-02-01
The broad array of expected loading conditions in a fusion reactor such as ITER necessitates high requirements on the plasma facing materials (PFMs). Tungsten, the PFM for the divertor region, the most affected part of the in-vessel components, must thus sustain severe, distinct exposure conditions. Accordingly, comprehensive experiments investigating sequential and simultaneous thermal and particle loads were performed on double forged pure tungsten, not only to investigate whether the thermal and particle loads cause damage but also if the sequence of exposure maintains an influence. The exposed specimens showed various kinds of damage such as roughening, blistering, and cracking at a base temperature where tungsten could be ductile enough to compensate the induced stresses exclusively by plastic deformation (Pintsuk et al 2011 J. Nucl. Mater. 417 481-6). It was found out that hydrogen has an adverse effect on the material performance and the loading sequence on the surface modification.
Qi, Hong; Qiao, Yao-Bin; Ren, Ya-Tao; Shi, Jing-Wen; Zhang, Ze-Yu; Ruan, Li-Ming
2016-10-17
Sequential quadratic programming (SQP) is used as an optimization algorithm to reconstruct the optical parameters based on the time-domain radiative transfer equation (TD-RTE). Numerous time-resolved measurement signals are obtained using the TD-RTE as forward model. For a high computational efficiency, the gradient of objective function is calculated using an adjoint equation technique. SQP algorithm is employed to solve the inverse problem and the regularization term based on the generalized Gaussian Markov random field (GGMRF) model is used to overcome the ill-posed problem. Simulated results show that the proposed reconstruction scheme performs efficiently and accurately.
Zhang, Chong; Yuan, Jingsong; Lu, Jianhua; Hou, Yingqin; Xiong, Wei; Lu, Hua
2018-02-03
The development of high-performance nonfouling polymer surfaces for implantable medical devices and therapeutic nanomaterials is of great importance. Elaborating the relationship of polymer structural characteristics and the resulted surface properties can offer useful guidance toward ideal biointerfaces. In this work, we investigate the effects of the helical conformation and anchoring orientation of poly(α-amino acid)s (PαAAs) to produce advanced nonfouling surfaces. By using the neutral poly(γ-(2-(2-(2-methoxyethoxy)ethoxy)ethoxy)esteryl glutamates) (P(EG 3 Glu)s) as a model system, the adsorption kinetics are monitored by ex-situ variable angle spectroscopic ellipsometry and in-situ quartz crystal microbalance with dissipation. It is found that the polymers adopting a rigid rod-like α-helical conformation can self-assemble more rapidly to produce denser adlayers, and generate significantly improved nonfouling surfaces compared to those flexible polymer analogues including the widely used antifouling polymer PEG. Moreover, the surface properties can be further enhanced by using the antiparallel orientated helical P(EG 3 Glu)s. Most importantly, the insights gained from the P(EG 3 Glu) model system are successfully applied to the generation of ultra-low-fouling surfaces using zwitterionic PαAAs brushes, underscoring the generality of the approach. Particularly, the surface based on the antiparallel aligned zwitterionic helical PαAAs exhibits ∼98-99% reduction of human serum adsorption relative to the bare gold, and gives almost no adhesion of mouse platelet. Taken together, this work depicts an extremely simple yet highly effective approach to manipulate surface properties for numerous applications in biomaterial interfaces, diagnostics, and biosensors. Copyright © 2018 Elsevier Ltd. All rights reserved.
Schrand, Amanda M; Lin, Jonathan B; Hens, Suzanne Ciftan; Hussain, Saber M
2011-02-01
Nanoparticles (NPs) offer promise for a multitude of biological applications including cellular probes at the bio-interface for targeted delivery of anticancer substances, Raman and fluorescent-based imaging and directed cell growth. Nanodiamonds (NDs), in particular, have several advantages compared to other carbon-based nanomaterials - including a rich surface chemistry useful for chemical conjugation, high biocompatibility with little reactive oxygen species (ROS) generation, physical and chemical stability that affords sterilization, high surface area to volume ratio, transparency and a high index of refraction. The visualization of ND internalization into cells is possible via photoluminescence, which is produced by direct dye conjugation or high energy irradiation that creates nitrogen vacancy centers. Here, we explore the kinetics and mechanisms involved in the intracellular uptake and localization of novel, highly-stable, fluorophore-conjugated NDs. Examination in a neuronal cell line (N2A) shows ND localization to early endosomes and lysosomes with eventual release into the cytoplasm. The addition of endocytosis and exocytosis inhibitors allows for diminished uptake and increased accumulation, respectively, which further corroborates cellular behavior in response to NDs. Ultimately, the ability of the NDs to travel throughout cellular compartments of varying pH without degradation of the surface-conjugated fluorophore or alteration of cell viability over extended periods of time is promising for their use in biomedical applications as stable, biocompatible, fluorescent probes.
Moving Sound Source Localization Based on Sequential Subspace Estimation in Actual Room Environments
NASA Astrophysics Data System (ADS)
Tsuji, Daisuke; Suyama, Kenji
This paper presents a novel method for moving sound source localization and its performance evaluation in actual room environments. The method is based on the MUSIC (MUltiple SIgnal Classification) which is one of the most high resolution localization methods. When using the MUSIC, a computation of eigenvectors of correlation matrix is required for the estimation. It needs often a high computational costs. Especially, in the situation of moving source, it becomes a crucial drawback because the estimation must be conducted at every the observation time. Moreover, since the correlation matrix varies its characteristics due to the spatial-temporal non-stationarity, the matrix have to be estimated using only a few observed samples. It makes the estimation accuracy degraded. In this paper, the PAST (Projection Approximation Subspace Tracking) is applied for sequentially estimating the eigenvectors spanning the subspace. In the PAST, the eigen-decomposition is not required, and therefore it is possible to reduce the computational costs. Several experimental results in the actual room environments are shown to present the superior performance of the proposed method.
Koopmeiners, Joseph S; Feng, Ziding
2011-01-01
The receiver operating characteristic (ROC) curve, the positive predictive value (PPV) curve and the negative predictive value (NPV) curve are three measures of performance for a continuous diagnostic biomarker. The ROC, PPV and NPV curves are often estimated empirically to avoid assumptions about the distributional form of the biomarkers. Recently, there has been a push to incorporate group sequential methods into the design of diagnostic biomarker studies. A thorough understanding of the asymptotic properties of the sequential empirical ROC, PPV and NPV curves will provide more flexibility when designing group sequential diagnostic biomarker studies. In this paper we derive asymptotic theory for the sequential empirical ROC, PPV and NPV curves under case-control sampling using sequential empirical process theory. We show that the sequential empirical ROC, PPV and NPV curves converge to the sum of independent Kiefer processes and show how these results can be used to derive asymptotic results for summaries of the sequential empirical ROC, PPV and NPV curves.
Koopmeiners, Joseph S.; Feng, Ziding
2013-01-01
The receiver operating characteristic (ROC) curve, the positive predictive value (PPV) curve and the negative predictive value (NPV) curve are three measures of performance for a continuous diagnostic biomarker. The ROC, PPV and NPV curves are often estimated empirically to avoid assumptions about the distributional form of the biomarkers. Recently, there has been a push to incorporate group sequential methods into the design of diagnostic biomarker studies. A thorough understanding of the asymptotic properties of the sequential empirical ROC, PPV and NPV curves will provide more flexibility when designing group sequential diagnostic biomarker studies. In this paper we derive asymptotic theory for the sequential empirical ROC, PPV and NPV curves under case-control sampling using sequential empirical process theory. We show that the sequential empirical ROC, PPV and NPV curves converge to the sum of independent Kiefer processes and show how these results can be used to derive asymptotic results for summaries of the sequential empirical ROC, PPV and NPV curves. PMID:24039313
NASA Astrophysics Data System (ADS)
Cuntz, Matthias; Mai, Juliane; Zink, Matthias; Thober, Stephan; Kumar, Rohini; Schäfer, David; Schrön, Martin; Craven, John; Rakovec, Oldrich; Spieler, Diana; Prykhodko, Vladyslav; Dalmasso, Giovanni; Musuuza, Jude; Langenberg, Ben; Attinger, Sabine; Samaniego, Luis
2015-08-01
Environmental models tend to require increasing computational time and resources as physical process descriptions are improved or new descriptions are incorporated. Many-query applications such as sensitivity analysis or model calibration usually require a large number of model evaluations leading to high computational demand. This often limits the feasibility of rigorous analyses. Here we present a fully automated sequential screening method that selects only informative parameters for a given model output. The method requires a number of model evaluations that is approximately 10 times the number of model parameters. It was tested using the mesoscale hydrologic model mHM in three hydrologically unique European river catchments. It identified around 20 informative parameters out of 52, with different informative parameters in each catchment. The screening method was evaluated with subsequent analyses using all 52 as well as only the informative parameters. Subsequent Sobol's global sensitivity analysis led to almost identical results yet required 40% fewer model evaluations after screening. mHM was calibrated with all and with only informative parameters in the three catchments. Model performances for daily discharge were equally high in both cases with Nash-Sutcliffe efficiencies above 0.82. Calibration using only the informative parameters needed just one third of the number of model evaluations. The universality of the sequential screening method was demonstrated using several general test functions from the literature. We therefore recommend the use of the computationally inexpensive sequential screening method prior to rigorous analyses on complex environmental models.
NASA Astrophysics Data System (ADS)
Mai, Juliane; Cuntz, Matthias; Zink, Matthias; Thober, Stephan; Kumar, Rohini; Schäfer, David; Schrön, Martin; Craven, John; Rakovec, Oldrich; Spieler, Diana; Prykhodko, Vladyslav; Dalmasso, Giovanni; Musuuza, Jude; Langenberg, Ben; Attinger, Sabine; Samaniego, Luis
2016-04-01
Environmental models tend to require increasing computational time and resources as physical process descriptions are improved or new descriptions are incorporated. Many-query applications such as sensitivity analysis or model calibration usually require a large number of model evaluations leading to high computational demand. This often limits the feasibility of rigorous analyses. Here we present a fully automated sequential screening method that selects only informative parameters for a given model output. The method requires a number of model evaluations that is approximately 10 times the number of model parameters. It was tested using the mesoscale hydrologic model mHM in three hydrologically unique European river catchments. It identified around 20 informative parameters out of 52, with different informative parameters in each catchment. The screening method was evaluated with subsequent analyses using all 52 as well as only the informative parameters. Subsequent Sobol's global sensitivity analysis led to almost identical results yet required 40% fewer model evaluations after screening. mHM was calibrated with all and with only informative parameters in the three catchments. Model performances for daily discharge were equally high in both cases with Nash-Sutcliffe efficiencies above 0.82. Calibration using only the informative parameters needed just one third of the number of model evaluations. The universality of the sequential screening method was demonstrated using several general test functions from the literature. We therefore recommend the use of the computationally inexpensive sequential screening method prior to rigorous analyses on complex environmental models.
Constrained optimization of sequentially generated entangled multiqubit states
NASA Astrophysics Data System (ADS)
Saberi, Hamed; Weichselbaum, Andreas; Lamata, Lucas; Pérez-García, David; von Delft, Jan; Solano, Enrique
2009-08-01
We demonstrate how the matrix-product state formalism provides a flexible structure to solve the constrained optimization problem associated with the sequential generation of entangled multiqubit states under experimental restrictions. We consider a realistic scenario in which an ancillary system with a limited number of levels performs restricted sequential interactions with qubits in a row. The proposed method relies on a suitable local optimization procedure, yielding an efficient recipe for the realistic and approximate sequential generation of any entangled multiqubit state. We give paradigmatic examples that may be of interest for theoretical and experimental developments.
Chadha, Neil K; Papsin, Blake C; Jiwani, Salima; Gordon, Karen A
2011-09-01
To measure speech detection in noise performance for children with bilateral cochlear implants (BiCI), to compare performance in children with simultaneous implant versus those with sequential implant, and to compare performance to normal-hearing children. Prospective cohort study. Tertiary academic pediatric center. Children with early-onset bilateral deafness and 2-year BiCI experience, comprising the "sequential" group (>2 yr interimplantation delay, n = 12) and "simultaneous group" (no interimplantation delay, n = 10) and normal-hearing controls (n = 8). Thresholds to speech detection (at 0-degree azimuth) were measured with noise at 0-degree azimuth or ± 90-degree azimuth. Spatial unmasking (SU) as the noise condition changed from 0-degree azimuth to ± 90-degree azimuth and binaural summation advantage (BSA) of 2 over 1 CI. Speech detection in noise was significantly poorer than controls for both BiCI groups (p < 0.0001). However, the SU in the simultaneous group approached levels found in normal controls (7.2 ± 0.6 versus 8.6 ± 0.6 dB, p > 0.05) and was significantly better than that in the sequential group (3.9 ± 0.4 dB, p < 0.05). Spatial unmasking was unaffected by the side of noise presentation in the simultaneous group but, in the sequential group, was significantly better when noise was moved to the second rather than the first implanted ear (4.8 ± 0.5 versus 3.0 ± 0.4 dB, p < 0.05). This was consistent with a larger BSA from the sequential group's second rather than first CI. Children with simultaneously implanted BiCI demonstrated an advantage over children with sequential implant by using spatial cues to improve speech detection in noise.
High data rate coding for the space station telemetry links.
NASA Technical Reports Server (NTRS)
Lumb, D. R.; Viterbi, A. J.
1971-01-01
Coding systems for high data rates were examined from the standpoint of potential application in space-station telemetry links. Approaches considered included convolutional codes with sequential, Viterbi, and cascaded-Viterbi decoding. It was concluded that a high-speed (40 Mbps) sequential decoding system best satisfies the requirements for the assumed growth potential and specified constraints. Trade-off studies leading to this conclusion are viewed, and some sequential (Fano) algorithm improvements are discussed, together with real-time simulation results.
NASA Astrophysics Data System (ADS)
Gallagher, C. B.; Ferraro, A.
2018-05-01
A possible alternative to the standard model of measurement-based quantum computation (MBQC) is offered by the sequential model of MBQC—a particular class of quantum computation via ancillae. Although these two models are equivalent under ideal conditions, their relative resilience to noise in practical conditions is not yet known. We analyze this relationship for various noise models in the ancilla preparation and in the entangling-gate implementation. The comparison of the two models is performed utilizing both the gate infidelity and the diamond distance as figures of merit. Our results show that in the majority of instances the sequential model outperforms the standard one in regard to a universal set of operations for quantum computation. Further investigation is made into the performance of sequential MBQC in experimental scenarios, thus setting benchmarks for possible cavity-QED implementations.
Crawford, Sara; Boulet, Sheree L; Mneimneh, Allison S; Perkins, Kiran M; Jamieson, Denise J; Zhang, Yujia; Kissin, Dmitry M
2016-02-01
To assess treatment and pregnancy/infant-associated medical costs and birth outcomes for assisted reproductive technology (ART) cycles in a subset of patients using elective double embryo (ET) and to project the difference in costs and outcomes had the cycles instead been sequential single ETs (fresh followed by frozen if the fresh ET did not result in live birth). Retrospective cohort study using 2012 and 2013 data from the National ART Surveillance System. Infertility treatment centers. Fresh, autologous double ETs performed in 2012 among ART patients younger than 35 years of age with no prior ART use who cryopreserved at least one embryo. Sequential single and double ETs. Actual live birth rates and estimated ART treatment and pregnancy/infant-associated medical costs for double ET cycles started in 2012 and projected ART treatment and pregnancy/infant-associated medical costs if the double ET cycles had been performed as sequential single ETs. The estimated total ART treatment and pregnancy/infant-associated medical costs were $580.9 million for 10,001 double ETs started in 2012. If performed as sequential single ETs, estimated costs would have decreased by $195.0 million to $386.0 million, and live birth rates would have increased from 57.7%-68.0%. Sequential single ETs, when clinically appropriate, can reduce total ART treatment and pregnancy/infant-associated medical costs by reducing multiple births without lowering live birth rates. Published by Elsevier Inc.
Water Dynamics in the Hydration Shells of Biomolecules
2017-01-01
The structure and function of biomolecules are strongly influenced by their hydration shells. Structural fluctuations and molecular excitations of hydrating water molecules cover a broad range in space and time, from individual water molecules to larger pools and from femtosecond to microsecond time scales. Recent progress in theory and molecular dynamics simulations as well as in ultrafast vibrational spectroscopy has led to new and detailed insight into fluctuations of water structure, elementary water motions, electric fields at hydrated biointerfaces, and processes of vibrational relaxation and energy dissipation. Here, we review recent advances in both theory and experiment, focusing on hydrated DNA, proteins, and phospholipids, and compare dynamics in the hydration shells to bulk water. PMID:28248491
ERIC Educational Resources Information Center
Xu, Chang; LeFevre, Jo-Anne
2016-01-01
Are there differential benefits of training sequential number knowledge versus spatial skills for children's numerical and spatial performance? Three- to five-year-old children (N = 84) participated in 1 session of either sequential training (e.g., what comes before and after the number 5?) or non-numerical spatial training (i.e., decomposition of…
O'Connell, Tríona M; King, Damien; Dixit, Chandra K; O'Connor, Brendan; Walls, Dermot; Ducrée, Jens
2014-09-21
It is now widely recognised that the earliest changes that occur on a cell when it is stressed or becoming diseased are alterations in its surface glycosylation. Current state-of-the-art technologies in glycoanalysis include mass spectrometry, protein microarray formats, techniques in cytometry and more recently, glyco-quantitative polymerase chain reaction (Glyco-qPCR). Techniques for the glycoprofiling of the surfaces of single cells are either limited to the analysis of large cell populations or are unable to handle multiple and/or sequential probing. Here, we report a novel approach of single live cell glycoprofiling enabled by the microfluidic "Lab-in-a-Trench" (LiaT) platform for performing capture and retention of cells, along with shear-free reagent loading and washing. The significant technical improvement on state-of-the-art is the demonstration of consecutive, spatio-temporally profiling of glycans on a single cell by sequential elution of the previous lectin probe using their corresponding free sugar. We have qualitatively analysed glycan density on the surface of individual cells. This has allowed us to qualitatively co-localise the observed glycans. This approach enables exhaustive glycoprofiling and glycan mapping on the surface of individual live cells with multiple lectins. The possibility of sequentially profiling glycans on cells will be a powerful new tool to add to current glycoanalytical techniques. The LiaT platform will enable cell biologists to perform many high sensitivity assays and also will also make a significant impact on biomarker research.
Simultaneous Versus Sequential Presentation in Testing Recognition Memory for Faces.
Finley, Jason R; Roediger, Henry L; Hughes, Andrea D; Wahlheim, Christopher N; Jacoby, Larry L
2015-01-01
Three experiments examined the issue of whether faces could be better recognized in a simul- taneous test format (2-alternative forced choice [2AFC]) or a sequential test format (yes-no). All experiments showed that when target faces were present in the test, the simultaneous procedure led to superior performance (area under the ROC curve), whether lures were high or low in similarity to the targets. However, when a target-absent condition was used in which no lures resembled the targets but the lures were similar to each other, the simultaneous procedure yielded higher false alarm rates (Experiments 2 and 3) and worse overall performance (Experi- ment 3). This pattern persisted even when we excluded responses that participants opted to withhold rather than volunteer. We conclude that for the basic recognition procedures used in these experiments, simultaneous presentation of alternatives (2AFC) generally leads to better discriminability than does sequential presentation (yes-no) when a target is among the alterna- tives. However, our results also show that the opposite can occur when there is no target among the alternatives. An important future step is to see whether these patterns extend to more realistic eyewitness lineup procedures. The pictures used in the experiment are available online at http://www.press.uillinois.edu/journals/ajp/media/testing_recognition/.
Development of a syringe pump assisted dynamic headspace sampling technique for needle trap device.
Eom, In-Yong; Niri, Vadoud H; Pawliszyn, Janusz
2008-07-04
This paper describes a new approach that combines needle trap devices (NTDs) with a dynamic headspace sampling technique (purge and trap) using a bidirectional syringe pump. The needle trap device is a 22-G stainless steel needle 3.5-in. long packed with divinylbenzene sorbent particles. The same sized needle, without packing, was used for purging purposes. We chose an aqueous mixture of benzene, toluene, ethylbenzene, and p-xylene (BTEX) and developed a sequential purge and trap (SPNT) method, in which sampling (trapping) and purging cycles were performed sequentially by the use of syringe pump with different distribution channels. In this technique, a certain volume (1 mL) of headspace was sequentially sampled using the needle trap; afterwards, the same volume of air was purged into the solution at a high flow rate. The proposed technique showed an effective extraction compared to the continuous purge and trap technique, with a minimal dilution effect. Method evaluation was also performed by obtaining the calibration graphs for aqueous BTEX solutions in the concentration range of 1-250 ng/mL. The developed technique was compared to the headspace solid-phase microextraction method for the analysis of aqueous BTEX samples. Detection limits as low as 1 ng/mL were obtained for BTEX by NTD-SPNT.
Comparative evaluation of three shaft seals proposed for high performance turbomachinery
NASA Technical Reports Server (NTRS)
Hendricks, R. C.
1982-01-01
Experimental pressure profiles and leak rate characteristics for three shaft seal prototype model configurations proposed for the space shuttle turbopump were assessed in the concentric and fully eccentric, to point of rub, positions without the effects of rotation. The parallel-cylindrical configuration has moderate to good stiffness with a higher leak rate. It represents a simple concept, but for practical reasons and possible increases in stability, all such seals should be conical-convergent. The three-stepdown-sequential, parallel-cylindrical seal is converging and represents good to possible high stiffness when fluid separation occurs, with a significant decrease in leak rate. Such seals can be very effective. The three-stepdown-sequential labyrinth seal of 33-teeth (i.e., 12-11-10 teeth from inlet to exit) provides excellent leak control but usually has very poor stiffness, depending on cavity design. The seal is complex and not recommended for dynamic control.
NASA Astrophysics Data System (ADS)
Chang, Po-Han; Liu, Shang-Yi; Lan, Yu-Bing; Tsai, Yi-Chen; You, Xue-Qian; Li, Chia-Shuo; Huang, Kuo-You; Chou, Ang-Sheng; Cheng, Tsung-Chin; Wang, Juen-Kai; Wu, Chih-I.
2017-04-01
In this work, graphene-methylammonium lead iodide (MAPbI3) perovskite hybrid phototransistors fabricated by sequential vapor deposition are demonstrated. Ultrahigh responsivity of 1.73 × 107 A W-1 and detectivity of 2 × 1015 Jones are achieved, with extremely high effective quantum efficiencies of about 108% in the visible range (450-700 nm). This excellent performance is attributed to the ultra-flat perovskite films grown by vapor deposition on the graphene sheets. The hybrid structure of graphene covered with uniform perovskite has high exciton separation ability under light exposure, and thus efficiently generates photocurrents. This paper presents photoluminescence (PL) images along with statistical analysis used to study the photo-induced exciton behavior. Both uniform and dramatic PL intensity quenching has been observed over entire measured regions, consistently demonstrating excellent exciton separation in the devices.
Chang, Po-Han; Liu, Shang-Yi; Lan, Yu-Bing; Tsai, Yi-Chen; You, Xue-Qian; Li, Chia-Shuo; Huang, Kuo-You; Chou, Ang-Sheng; Cheng, Tsung-Chin; Wang, Juen-Kai; Wu, Chih-I
2017-01-01
In this work, graphene-methylammonium lead iodide (MAPbI3) perovskite hybrid phototransistors fabricated by sequential vapor deposition are demonstrated. Ultrahigh responsivity of 1.73 × 107 A W−1 and detectivity of 2 × 1015 Jones are achieved, with extremely high effective quantum efficiencies of about 108% in the visible range (450–700 nm). This excellent performance is attributed to the ultra-flat perovskite films grown by vapor deposition on the graphene sheets. The hybrid structure of graphene covered with uniform perovskite has high exciton separation ability under light exposure, and thus efficiently generates photocurrents. This paper presents photoluminescence (PL) images along with statistical analysis used to study the photo-induced exciton behavior. Both uniform and dramatic PL intensity quenching has been observed over entire measured regions, consistently demonstrating excellent exciton separation in the devices. PMID:28422117
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Haining; Li, Weiping; Liu, Huicong
2010-07-15
A suitable deposition method of CdS is necessary for the high performance CdS-sensitized ZnO electrodes. In this paper, chemical bath deposition (CBD) and sequential chemical bath deposition (S-CBD) methods were used to deposit CdS on ZnO mesoporous films for ZnO/CdS electrodes. The analysis results of XRD patterns and UV-vis spectroscopy indicated that CBD deposition method leaded to the dissolving of ZnO mesoporous films in deposition solution and thickness reduction of ZnO/CdS electrodes. Absorption in visible region by the ZnO/CdS electrodes with CdS deposition by S-CBD was enhanced as deposition cycles increased due to the stability of ZnO mesoporous films inmore » the S-CBD deposition solutions. The results of photocurrent-voltage (I-V) measurement showed that the performance of ZnO/CdS electrodes with CdS deposition by CBD first increased and then decreased as deposition time increased, and the greatest short-circuit current (J{sub sc}) was obtained at the deposition time of 4 min. The performance of ZnO/CdS electrodes with CdS deposition by S-CBD increased as deposition cycles increased, and both open-circuit voltage (V{sub oc}) and J{sub sc} were greater than those electrodes with CdS deposition by CBD when the deposition cycles of S-CBD were 10 or greater. These results indicated that S-CBD is a more suitable method for high performance ZnO/CdS electrodes. (author)« less
A conformal, bio-interfaced class of silicon electronics for mapping cardiac electrophysiology.
Viventi, Jonathan; Kim, Dae-Hyeong; Moss, Joshua D; Kim, Yun-Soung; Blanco, Justin A; Annetta, Nicholas; Hicks, Andrew; Xiao, Jianliang; Huang, Younggang; Callans, David J; Rogers, John A; Litt, Brian
2010-03-24
In all current implantable medical devices such as pacemakers, deep brain stimulators, and epilepsy treatment devices, each electrode is independently connected to separate control systems. The ability of these devices to sample and stimulate tissues is hindered by this configuration and by the rigid, planar nature of the electronics and the electrode-tissue interfaces. Here, we report the development of a class of mechanically flexible silicon electronics for multiplexed measurement of signals in an intimate, conformal integrated mode on the dynamic, three-dimensional surfaces of soft tissues in the human body. We demonstrate this technology in sensor systems composed of 2016 silicon nanomembrane transistors configured to record electrical activity directly from the curved, wet surface of a beating porcine heart in vivo. The devices sample with simultaneous submillimeter and submillisecond resolution through 288 amplified and multiplexed channels. We use this system to map the spread of spontaneous and paced ventricular depolarization in real time, at high resolution, on the epicardial surface in a porcine animal model. This demonstration is one example of many possible uses of this technology in minimally invasive medical devices.
Hajj-Hassan, Mohamad; Khayyat-Kholghi, Maedeh; Wang, Huifen; Chodavarapu, Vamsy; Henderson, Janet E
2011-11-01
Porous silicon shows great promise as a bio-interface material due to its large surface to volume ratio, its stability in aqueous solutions and to the ability to precisely regulate its pore characteristics. In the current study, porous silicon scaffolds were fabricated from single crystalline silicon wafers by a novel xenon difluoride dry etching technique. This simplified dry etch fabrication process allows selective formation of porous silicon using a standard photoresist as mask material and eliminates the post-formation drying step typically required for the wet etching techniques, thereby reducing the risk of damaging the newly formed porous silicon. The porous silicon scaffolds supported the growth of primary cultures of bone marrow derived mesenchymal stromal cells (MSC) plated at high density for up to 21 days in culture with no significant loss of viability, assessed using Alamar Blue. Scanning electron micrographs confirmed a dense lawn of cells at 9 days of culture and the presence of MSC within the pores of the porous silicon scaffolds. Copyright © 2011 Wiley Periodicals, Inc.
[Co-composting high moisture vegetable waste and flower waste in a sequential fed operation].
Zhang, Xiangfeng; Wang, Hongtao; Nie, Yongfeng
2003-11-01
Co-composting of high moisture vegetable wastes (celery and cabbage) and flower wastes (carnation) were studied in a sequential fed bed. The preliminary materials of composting were celery and carnation wastes. The sequential fed materials of composting were cabbage wastes and were fed every 4 days. Moisture content of mixture materials was between 60% and 70%. Composting was done in an aerobic static bed of composting based temperature feedback and control via aeration rate regulation. Aeration was ended when temperature of the pile was about 40 degrees C. Changes of composting of temperature, aeration rate, water content, organic matter, ash, pH, volume, NH4(+)-N, and NO3(-)-N were studied. Results show that co-composting of high moisture vegetable wastes and flower wastes, in a sequential fed aerobic static bed based temperature feedback and control via aeration rate regulation, can stabilize organic matter and removal water rapidly. The sequential fed operation are effective to overcome the difficult which traditional composting cannot applied successfully where high moisture vegetable wastes in more excess of flower wastes, such as Dianchi coastal.
Integration deficiencies associated with continuous limb movement sequences in Parkinson's disease.
Park, Jin-Hoon; Stelmach, George E
2009-11-01
The present study examined the extent to which Parkinson's disease (PD) influences integration of continuous limb movement sequences. Eight patients with idiopathic PD and 8 age-matched normal subjects were instructed to perform repetitive sequential aiming movements to specified targets under three-accuracy constraints: 1) low accuracy (W = 7 cm) - minimal accuracy constraint, 2) high accuracy (W = 0.64 cm) - maximum accuracy constraint, and 3) mixed accuracy constraint - one target of high accuracy and another target of low accuracy. The characteristic of sequential movements in the low accuracy condition was mostly cyclical, whereas in the high accuracy condition it was discrete in both groups. When the accuracy constraint was mixed, the sequential movements were executed by assembling discrete and cyclical movements in both groups, suggesting that for PD patients the capability to combine discrete and cyclical movements to meet a task requirement appears to be intact. However, such functional linkage was not as pronounced as was in normal subjects. Close examination of movement from the mixed accuracy condition revealed marked movement hesitations in the vicinity of the large target in PD patients, resulting in a bias toward discrete movement. These results suggest that PD patients may have deficits in ongoing planning and organizing processes during movement execution when the tasks require to assemble various accuracy requirements into more complex movement sequences.
Numerical study on the sequential Bayesian approach for radioactive materials detection
NASA Astrophysics Data System (ADS)
Qingpei, Xiang; Dongfeng, Tian; Jianyu, Zhu; Fanhua, Hao; Ge, Ding; Jun, Zeng
2013-01-01
A new detection method, based on the sequential Bayesian approach proposed by Candy et al., offers new horizons for the research of radioactive detection. Compared with the commonly adopted detection methods incorporated with statistical theory, the sequential Bayesian approach offers the advantages of shorter verification time during the analysis of spectra that contain low total counts, especially in complex radionuclide components. In this paper, a simulation experiment platform implanted with the methodology of sequential Bayesian approach was developed. Events sequences of γ-rays associating with the true parameters of a LaBr3(Ce) detector were obtained based on an events sequence generator using Monte Carlo sampling theory to study the performance of the sequential Bayesian approach. The numerical experimental results are in accordance with those of Candy. Moreover, the relationship between the detection model and the event generator, respectively represented by the expected detection rate (Am) and the tested detection rate (Gm) parameters, is investigated. To achieve an optimal performance for this processor, the interval of the tested detection rate as a function of the expected detection rate is also presented.
Trott, C M; Ouyang, J; El Fakhri, G
2010-11-21
Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.
Hernández-Torrano, Daniel; Ali, Syed; Chan, Chee-Kai
2017-08-08
Students commencing their medical training arrive with different educational backgrounds and a diverse range of learning experiences. Consequently, students would have developed preferred approaches to acquiring and processing information or learning style preferences. Understanding first-year students' learning style preferences is important to success in learning. However, little is understood about how learning styles impact learning and performance across different subjects within the medical curriculum. Greater understanding of the relationship between students' learning style preferences and academic performance in specific medical subjects would be valuable. This cross-sectional study examined the learning style preferences of first-year medical students and how they differ across gender. This research also analyzed the effect of learning styles on academic performance across different subjects within a medical education program in a Central Asian university. A total of 52 students (57.7% females) from two batches of first-year medical school completed the Index of Learning Styles Questionnaire, which measures four dimensions of learning styles: sensing-intuitive; visual-verbal; active-reflective; sequential-global. First-year medical students reported preferences for visual (80.8%) and sequential (60.5%) learning styles, suggesting that these students preferred to learn through demonstrations and diagrams and in a linear and sequential way. Our results indicate that male medical students have higher preference for visual learning style over verbal, while females seemed to have a higher preference for sequential learning style over global. Significant associations were found between sensing-intuitive learning styles and performance in Genetics [β = -0.46, B = -0.44, p < 0.01] and Anatomy [β = -0.41, B = -0.61, p < 0.05] and between sequential-global styles and performance in Genetics [β = 0.36, B = 0.43, p < 0.05]. More specifically, sensing learners were more likely to perform better than intuitive learners in the two subjects and global learners were more likely to perform better than sequential learners in Genetics. This knowledge will be helpful to individual students to improve their performance in these subjects by adopting new sensing learning techniques. Instructors can also benefit by modifying and adapting more appropriate teaching approaches in these subjects. Future studies to validate this observation will be valuable.
Cardinality enhancement utilizing Sequential Algorithm (SeQ) code in OCDMA system
NASA Astrophysics Data System (ADS)
Fazlina, C. A. S.; Rashidi, C. B. M.; Rahman, A. K.; Aljunid, S. A.
2017-11-01
Optical Code Division Multiple Access (OCDMA) has been important with increasing demand for high capacity and speed for communication in optical networks because of OCDMA technique high efficiency that can be achieved, hence fibre bandwidth is fully used. In this paper we will focus on Sequential Algorithm (SeQ) code with AND detection technique using Optisystem design tool. The result revealed SeQ code capable to eliminate Multiple Access Interference (MAI) and improve Bit Error Rate (BER), Phase Induced Intensity Noise (PIIN) and orthogonally between users in the system. From the results, SeQ shows good performance of BER and capable to accommodate 190 numbers of simultaneous users contrast with existing code. Thus, SeQ code have enhanced the system about 36% and 111% of FCC and DCS code. In addition, SeQ have good BER performance 10-25 at 155 Mbps in comparison with 622 Mbps, 1 Gbps and 2 Gbps bit rate. From the plot graph, 155 Mbps bit rate is suitable enough speed for FTTH and LAN networks. Resolution can be made based on the superior performance of SeQ code. Thus, these codes will give an opportunity in OCDMA system for better quality of service in an optical access network for future generation's usage
Peter, Beate
2018-01-01
In a companion study, adults with dyslexia and adults with a probable history of childhood apraxia of speech showed evidence of difficulty with processing sequential information during nonword repetition, multisyllabic real word repetition and nonword decoding. Results suggested that some errors arose in visual encoding during nonword reading, all levels of processing but especially short-term memory storage/retrieval during nonword repetition, and motor planning and programming during complex real word repetition. To further investigate the role of short-term memory, a participant with short-term memory impairment (MI) was recruited. MI was confirmed with poor performance during a sentence repetition and three nonword repetition tasks, all of which have a high short-term memory load, whereas typical performance was observed during tests of reading, spelling, and static verbal knowledge, all with low short-term memory loads. Experimental results show error-free performance during multisyllabic real word repetition but high counts of sequence errors, especially migrations and assimilations, during nonword repetition, supporting short-term memory as a locus of sequential processing deficit during nonword repetition. Results are also consistent with the hypothesis that during complex real word repetition, short-term memory is bypassed as the word is recognized and retrieved from long-term memory prior to producing the word.
Spatial-sequential and spatial-simultaneous working memory in individuals with Williams syndrome.
Lanfranchi, Silvia; De Mori, Letizia; Mammarella, Irene C; Carretti, Barbara; Vianello, Renzo
2015-05-01
The aim of the present study was to compare visuospatial working memory performance in 18 individuals with Williams syndrome (WS) and 18 typically developing (TD) children matched for nonverbal mental age. Two aspects were considered: task presentation format (i.e., spatial-sequential or spatial-simultaneous), and level of attentional control (i.e., passive or active tasks). Our results showed that individuals with WS performed less well than TD children in passive spatial-simultaneous tasks, but not in passive spatial-sequential tasks. The former's performance was also worse in both active tasks. These findings suggest an impairment in the spatial-simultaneous working memory of individuals with WS, together with a more generalized difficulty in tasks requiring information storage and concurrent processing, as seen in other etiologies of intellectual disability.
Aukema, Sietse M; Theil, Laura; Rohde, Marius; Bauer, Benedikt; Bradtke, Jutta; Burkhardt, Birgit; Bonn, Bettina R; Claviez, Alexander; Gattenlöhner, Stefan; Makarova, Olga; Nagel, Inga; Oschlies, Ilske; Pott, Christiane; Szczepanowski, Monika; Traulsen, Arne; Kluin, Philip M; Klapper, Wolfram; Siebert, Reiner; Murga Penas, Eva M
2015-09-01
Typical Burkitt lymphoma is characterized by an IG-MYC translocation and overall low genomic complexity. Clinically, Burkitt lymphoma has a favourable prognosis with very few relapses. However, the few patients experiencing disease progression and/or relapse have a dismal outcome. Here we report cytogenetic findings of seven cases of Burkitt lymphoma in which sequential karyotyping was performed at time of diagnosis and/or disease progression/relapse(s). After case selection, karyotype re-review and additional molecular analyses were performed in six paediatric cases, treated in Berlin-Frankfurt-Münster-Non-Hodgkin lymphoma study group trials, and one additional adult patient. Moreover, we analysed 18 cases of Burkitt lymphoma from the Mitelman database in which sequential karyotyping was performed. Our findings show secondary karyotypes to have a significant increase in load of cytogenetic aberrations with a mean number of 2, 5 and 8 aberrations for primary, secondary and third investigations. Importantly, this increase in karyotype complexity seemed to result from recurrent secondary chromosomal changes involving mainly trisomy 21, gains of 1q and 7q, losses of 6q, 11q, 13q, and 17p. In addition, our findings indicate a linear clonal evolution to be the predominant manner of cytogenetic evolution. Our data may provide a biological framework for the dismal outcome of progressive and relapsing Burkitt lymphoma. © 2015 John Wiley & Sons Ltd.
A temporary deficiency in self-control: Can heightened motivation overcome this effect?
Kelly, Claire L; Crawford, Trevor J; Gowen, Emma; Richardson, Kelly; Sünram-Lea, Sandra I
2017-05-01
Self-control is important for everyday life and involves behavioral regulation. Self-control requires effort, and when completing two successive self-control tasks, there is typically a temporary drop in performance in the second task. High self-reported motivation and being made self-aware somewhat counteract this effect-with the result that performance in the second task is enhanced. The current study explored the relationship between self-awareness and motivation on sequential self-control task performance. Before employing self-control in an antisaccade task, participants initially applied self-control in an incongruent Stroop task or completed a control task. After the Stroop task, participants unscrambled sentences that primed self-awareness (each started with the word "I") or unscrambled neutral sentences. Motivation was measured after the antisaccade task. Findings revealed that, after exerting self-control in the incongruent Stroop task, motivation predicted erroneous responses in the antisaccade task for those that unscrambled neutral sentences, and high motivation led to fewer errors. Those primed with self-awareness were somewhat more motivated overall, but motivation did not significantly predict antisaccade performance. Supporting the resource allocation account, if one was motivated-intrinsically or via the manipulation of self-awareness-resources were allocated to both tasks leading to the successful completion of two sequential self-control tasks. © 2017 The Authors. Psychophysiology published by Wiley Periodicals, Inc. on behalf of Society for Psychophysiological Research.
An extended sequential goodness-of-fit multiple testing method for discrete data.
Castro-Conde, Irene; Döhler, Sebastian; de Uña-Álvarez, Jacobo
2017-10-01
The sequential goodness-of-fit (SGoF) multiple testing method has recently been proposed as an alternative to the familywise error rate- and the false discovery rate-controlling procedures in high-dimensional problems. For discrete data, the SGoF method may be very conservative. In this paper, we introduce an alternative SGoF-type procedure that takes into account the discreteness of the test statistics. Like the original SGoF, our new method provides weak control of the false discovery rate/familywise error rate but attains false discovery rate levels closer to the desired nominal level, and thus it is more powerful. We study the performance of this method in a simulation study and illustrate its application to a real pharmacovigilance data set.
Sequential ranging integration times in the presence of CW interference in the ranging channel
NASA Technical Reports Server (NTRS)
Mathur, Ashok; Nguyen, Tien
1986-01-01
The Deep Space Network (DSN), managed by the Jet Propulsion Laboratory for NASA, is used primarily for communication with interplanetary spacecraft. The high sensitivity required to achieve planetary communications makes the DSN very susceptible to radio-frequency interference (RFI). In this paper, an analytical model is presented of the performance degradation of the DSN sequential ranging subsystem in the presence of downlink CW interference in the ranging channel. A trade-off between the ranging component integration times and the ranging signal-to-noise ratio to achieve a desired level of range measurement accuracy and the probability of error in the code components is also presented. Numerical results presented illustrate the required trade-offs under various interference conditions.
Two-IMU FDI performance of the sequential probability ratio test during shuttle entry
NASA Technical Reports Server (NTRS)
Rich, T. M.
1976-01-01
Performance data for the sequential probability ratio test (SPRT) during shuttle entry are presented. Current modeling constants and failure thresholds are included for the full mission 3B from entry through landing trajectory. Minimum 100 percent detection/isolation failure levels and a discussion of the effects of failure direction are presented. Finally, a limited comparison of failures introduced at trajectory initiation shows that the SPRT algorithm performs slightly worse than the data tracking test.
Wells, Gary L; Steblay, Nancy K; Dysart, Jennifer E
2015-02-01
Eyewitnesses (494) to actual crimes in 4 police jurisdictions were randomly assigned to view simultaneous or sequential photo lineups using laptop computers and double-blind administration. The sequential procedure used in the field experiment mimicked how it is conducted in actual practice (e.g., using a continuation rule, witness does not know how many photos are to be viewed, witnesses resolve any multiple identifications), which is not how most lab experiments have tested the sequential lineup. No significant differences emerged in rates of identifying lineup suspects (25% overall) but the sequential procedure produced a significantly lower rate (11%) of identifying known-innocent lineup fillers than did the simultaneous procedure (18%). The simultaneous/sequential pattern did not significantly interact with estimator variables and no lineup-position effects were observed for either the simultaneous or sequential procedures. Rates of nonidentification were not significantly different for simultaneous and sequential but nonidentifiers from the sequential procedure were more likely to use the "not sure" response option than were nonidentifiers from the simultaneous procedure. Among witnesses who made an identification, 36% (41% of simultaneous and 32% of sequential) identified a known-innocent filler rather than a suspect, indicating that eyewitness performance overall was very poor. The results suggest that the sequential procedure that is used in the field reduces the identification of known-innocent fillers, but the differences are relatively small.
Recchia, Gabriel; Sahlgren, Magnus; Kanerva, Pentti; Jones, Michael N.
2015-01-01
Circular convolution and random permutation have each been proposed as neurally plausible binding operators capable of encoding sequential information in semantic memory. We perform several controlled comparisons of circular convolution and random permutation as means of encoding paired associates as well as encoding sequential information. Random permutations outperformed convolution with respect to the number of paired associates that can be reliably stored in a single memory trace. Performance was equal on semantic tasks when using a small corpus, but random permutations were ultimately capable of achieving superior performance due to their higher scalability to large corpora. Finally, “noisy” permutations in which units are mapped to other units arbitrarily (no one-to-one mapping) perform nearly as well as true permutations. These findings increase the neurological plausibility of random permutations and highlight their utility in vector space models of semantics. PMID:25954306
Qin, Fangjun; Chang, Lubin; Jiang, Sai; Zha, Feng
2018-05-03
In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms.
A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations
Qin, Fangjun; Jiang, Sai; Zha, Feng
2018-01-01
In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms. PMID:29751538
Optimal sequential measurements for bipartite state discrimination
NASA Astrophysics Data System (ADS)
Croke, Sarah; Barnett, Stephen M.; Weir, Graeme
2017-05-01
State discrimination is a useful test problem with which to clarify the power and limitations of different classes of measurement. We consider the problem of discriminating between given states of a bipartite quantum system via sequential measurement of the subsystems, with classical feed-forward of measurement results. Our aim is to understand when sequential measurements, which are relatively easy to implement experimentally, perform as well, or almost as well, as optimal joint measurements, which are in general more technologically challenging. We construct conditions that the optimal sequential measurement must satisfy, analogous to the well-known Helstrom conditions for minimum error discrimination in the unrestricted case. We give several examples and compare the optimal probability of correctly identifying the state via global versus sequential measurement strategies.
Liu, Sonia Y; Chrystal, Peter V; Cowieson, Aaron J; Truong, Ha H; Moss, Amy F; Selle, Peter H
2017-01-01
A total of 360 male Ross 308 broiler chickens were used in a feeding study to assess the influence of macronutrients and energy density on feed intakes from 10 to 31 days post-hatch. The study comprised ten dietary treatments from five dietary combinations and two feeding approaches: sequential and choice feeding. The study included eight experimental diets and each dietary combination was made from three experimental diets. Choice fed birds selected between three diets in separate feed trays at the same time; whereas the three diets were offered to sequentially fed birds on an alternate basis during the experimental period. There were no differences between starch and protein intakes between choice and sequentially fed birds (P > 0.05) when broiler chickens selected between diets with different starch, protein and lipid concentrations. When broiler chickens selected between diets with different starch and protein but similar lipid concentrations, both sequentially and choice fed birds selected similar ratios of starch and protein intake (P > 0.05). However, when broiler chickens selected from diets with different protein and lipid but similar starch concentrations, choice fed birds had higher lipid intake (129 versus 118 g/bird, P = 0.027) and selected diets with lower protein concentrations (258 versus 281 g/kg, P = 0.042) than birds offered sequential diet options. Choice fed birds had greater intakes of the high energy diet (1471 g/bird, P < 0.0001) than low energy (197 g/bird) or medium energy diets (663 g/bird) whilst broiler chickens were offered diets with different energy densities but high crude protein (300 g/kg) or digestible lysine (17.5 g/kg) concentrations. Choice fed birds had lower FCR (1.217 versus 1.327 g/g, P < 0.0001) and higher carcass yield (88.1 versus 87.3%, P = 0.012) than sequentially fed birds. This suggests that the dietary balance between protein and energy is essential for optimal feed conversion efficiency. The intake path of macronutrients from 10-31 days in choice and sequential feeding groups were plotted and compared with the null path if broiler chickens selected equal amounts of the three diets in the combination. Regardless of feeding regimen, the intake paths of starch and protein are very close to the null path; however, lipid and protein intake paths in choice fed birds are father from the null path than sequentially fed birds.
Chrystal, Peter V.; Cowieson, Aaron J.; Truong, Ha H.; Moss, Amy F.; Selle, Peter H.
2017-01-01
A total of 360 male Ross 308 broiler chickens were used in a feeding study to assess the influence of macronutrients and energy density on feed intakes from 10 to 31 days post-hatch. The study comprised ten dietary treatments from five dietary combinations and two feeding approaches: sequential and choice feeding. The study included eight experimental diets and each dietary combination was made from three experimental diets. Choice fed birds selected between three diets in separate feed trays at the same time; whereas the three diets were offered to sequentially fed birds on an alternate basis during the experimental period. There were no differences between starch and protein intakes between choice and sequentially fed birds (P > 0.05) when broiler chickens selected between diets with different starch, protein and lipid concentrations. When broiler chickens selected between diets with different starch and protein but similar lipid concentrations, both sequentially and choice fed birds selected similar ratios of starch and protein intake (P > 0.05). However, when broiler chickens selected from diets with different protein and lipid but similar starch concentrations, choice fed birds had higher lipid intake (129 versus 118 g/bird, P = 0.027) and selected diets with lower protein concentrations (258 versus 281 g/kg, P = 0.042) than birds offered sequential diet options. Choice fed birds had greater intakes of the high energy diet (1471 g/bird, P < 0.0001) than low energy (197 g/bird) or medium energy diets (663 g/bird) whilst broiler chickens were offered diets with different energy densities but high crude protein (300 g/kg) or digestible lysine (17.5 g/kg) concentrations. Choice fed birds had lower FCR (1.217 versus 1.327 g/g, P < 0.0001) and higher carcass yield (88.1 versus 87.3%, P = 0.012) than sequentially fed birds. This suggests that the dietary balance between protein and energy is essential for optimal feed conversion efficiency. The intake path of macronutrients from 10–31 days in choice and sequential feeding groups were plotted and compared with the null path if broiler chickens selected equal amounts of the three diets in the combination. Regardless of feeding regimen, the intake paths of starch and protein are very close to the null path; however, lipid and protein intake paths in choice fed birds are father from the null path than sequentially fed birds. PMID:29053729
High-speed multiple sequence alignment on a reconfigurable platform.
Oliver, Tim; Schmidt, Bertil; Maskell, Douglas; Nathan, Darran; Clemens, Ralf
2006-01-01
Progressive alignment is a widely used approach to compute multiple sequence alignments (MSAs). However, aligning several hundred sequences by popular progressive alignment tools requires hours on sequential computers. Due to the rapid growth of sequence databases biologists have to compute MSAs in a far shorter time. In this paper we present a new approach to MSA on reconfigurable hardware platforms to gain high performance at low cost. We have constructed a linear systolic array to perform pairwise sequence distance computations using dynamic programming. This results in an implementation with significant runtime savings on a standard FPGA.
Harari, Colin M; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T; Lubner, Meghan G; Hinshaw, J Louis; Ziemlewicz, Timothy; Brace, Christopher L
2016-01-01
To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015.
Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal
2015-04-01
Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of <-30 ms was recorded at those ablation sites. LVOT VAs originating from intramural foci could usually be eliminated by sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.
Christiansen, Morten H.; Conway, Christopher M.; Onnis, Luca
2011-01-01
We used event-related potentials (ERPs) to investigate the time course and distribution of brain activity while adults performed (a) a sequential learning task involving complex structured sequences, and (b) a language processing task. The same positive ERP deflection, the P600 effect, typically linked to difficult or ungrammatical syntactic processing, was found for structural incongruencies in both sequential learning as well as natural language, and with similar topographical distributions. Additionally, a left anterior negativity (LAN) was observed for language but not for sequential learning. These results are interpreted as an indication that the P600 provides an index of violations and the cost of integration of expectations for upcoming material when processing complex sequential structure. We conclude that the same neural mechanisms may be recruited for both syntactic processing of linguistic stimuli and sequential learning of structured sequence patterns more generally. PMID:23678205
Dry minor mergers and size evolution of high-z compact massive early-type galaxies
NASA Astrophysics Data System (ADS)
Oogi, Taira; Habe, Asao
2013-01-01
Recent observations show evidence that high-z (z ˜ 2-3) early-type galaxies (ETGs) are more compact than those with comparable mass at z ˜ 0. Such size evolution is most likely explained by the `dry merger sceanario'. However, previous studies based on this scenario cannot consistently explain the properties of both high-z compact massive ETGs and local ETGs. We investigate the effect of multiple sequential dry minor mergers on the size evolution of compact massive ETGs. From an analysis of the Millennium Simulation Data Base, we show that such minor (stellar mass ratio M2/M1 < 1/4) mergers are extremely common during hierarchical structure formation. We perform N-body simulations of sequential minor mergers with parabolic and head-on orbits, including a dark matter component and a stellar component. Typical mass ratios of these minor mergers are 1/20 < M2/M1 ≤q 1/10. We show that sequential minor mergers of compact satellite galaxies are the most efficient at promoting size growth and decreasing the velocity dispersion of compact massive ETGs in our simulations. The change of stellar size and density of the merger remnants is consistent with recent observations. Furthermore, we construct the merger histories of candidates for high-z compact massive ETGs using the Millennium Simulation Data Base and estimate the size growth of the galaxies through the dry minor merger scenario. We can reproduce the mean size growth factor between z = 2 and z = 0, assuming the most efficient size growth obtained during sequential minor mergers in our simulations. However, we note that our numerical result is only valid for merger histories with typical mass ratios between 1/20 and 1/10 with parabolic and head-on orbits and that our most efficient size-growth efficiency is likely an upper limit.
NASA Technical Reports Server (NTRS)
Waheed, Abdul; Yan, Jerry
1998-01-01
This paper presents a model to evaluate the performance and overhead of parallelizing sequential code using compiler directives for multiprocessing on distributed shared memory (DSM) systems. With increasing popularity of shared address space architectures, it is essential to understand their performance impact on programs that benefit from shared memory multiprocessing. We present a simple model to characterize the performance of programs that are parallelized using compiler directives for shared memory multiprocessing. We parallelized the sequential implementation of NAS benchmarks using native Fortran77 compiler directives for an Origin2000, which is a DSM system based on a cache-coherent Non Uniform Memory Access (ccNUMA) architecture. We report measurement based performance of these parallelized benchmarks from four perspectives: efficacy of parallelization process; scalability; parallelization overhead; and comparison with hand-parallelized and -optimized version of the same benchmarks. Our results indicate that sequential programs can conveniently be parallelized for DSM systems using compiler directives but realizing performance gains as predicted by the performance model depends primarily on minimizing architecture-specific data locality overhead.
Initial experience of using high field strength intraoperative MRI for neurosurgical procedures.
Raheja, Amol; Tandon, Vivek; Suri, Ashish; Sarat Chandra, P; Kale, Shashank S; Garg, Ajay; Pandey, Ravindra M; Kalaivani, Mani; Mahapatra, Ashok K; Sharma, Bhawani S
2015-08-01
We report our initial experience to optimize neurosurgical procedures using high field strength intraoperative magnetic resonance imaging (IOMRI) in 300 consecutive patients as high field strength IOMRI rapidly becomes the standard of care for neurosurgical procedures. Three sequential groups (groups A, B, C; n=100 each) were compared with respect to time management, complications and technical difficulties to assess improvement in these parameters with experience. We observed a reduction in the number of technical difficulties (p<0.001), time to induction (p<0.001) and total anesthesia time (p=0.007) in sequential groups. IOMRI was performed for neuronavigation guidance (n=252) and intraoperative validation of extent of resection (EOR; n=67). Performing IOMRI increased the EOR over and beyond the primary surgical attempt in 20.5% (29/141) and 18% (11/61) of patients undergoing glioma and pituitary surgery, respectively. Overall, EOR improved in 59.7% of patients undergoing IOMRI (40/67). Intraoperative tractography and real time navigation using re-uploaded IOMRI images (accounting for brain shift) helps in intraoperative planning to reduce complications. IOMRI is an asset to neurosurgeons, helping to augment the EOR, especially in glioma and pituitary surgery, with no significant increase in morbidity to the patient. Copyright © 2015 Elsevier Ltd. All rights reserved.
Manabe, Kengo; Matsubayashi, Takeshi; Tenjimbayashi, Mizuki; Moriya, Takeo; Tsuge, Yosuke; Kyung, Kyu-Hong; Shiratori, Seimei
2016-09-29
Inspired by biointerfaces, such as the surfaces of lotus leaves and pitcher plants, researchers have developed innovative strategies for controlling surface wettability and transparency. In particular, great success has been achieved in obtaining low adhesion and high transmittance via the introduction of a liquid layer to form liquid-infused surfaces. Furthermore, smart surfaces that can change their surface properties according to external stimuli have recently attracted substantial interest. As some of the best-performing smart surface materials, slippery liquid-infused porous surfaces (SLIPSs), which are super-repellent, demonstrate the successful achievement of switchable adhesion and tunable transparency that can be controlled by a graded mechanical stimulus. However, despite considerable efforts, producing temperature-responsive, super-repellent surfaces at ambient temperature and pressure remains difficult because of the use of nonreactive lubricant oil as a building block in previously investigated repellent surfaces. Therefore, the present study focused on developing multifunctional materials that dynamically adapt to temperature changes. Here, we demonstrate temperature-activated solidifiable/liquid paraffin-infused porous surfaces (TA-SLIPSs) whose transparency and control of water droplet movement at room temperature can be simultaneously controlled. The solidification of the paraffin changes the surface morphology and the size of the light-transmission inhibitor in the lubricant layer; as a result, the control over the droplet movement and the light transmittance at different temperatures is dependent on the solidifiable/liquid paraffin mixing ratio. Further study of such temperature-responsive, multifunctional systems would be valuable for antifouling applications and the development of surfaces with tunable optical transparency for innovative medical applications, intelligent windows, and other devices.
Orphan therapies: making best use of postmarket data.
Maro, Judith C; Brown, Jeffrey S; Dal Pan, Gerald J; Li, Lingling
2014-08-01
Postmarket surveillance of the comparative safety and efficacy of orphan therapeutics is challenging, particularly when multiple therapeutics are licensed for the same orphan indication. To make best use of product-specific registry data collected to fulfill regulatory requirements, we propose the creation of a distributed electronic health data network among registries. Such a network could support sequential statistical analyses designed to detect early warnings of excess risks. We use a simulated example to explore the circumstances under which a distributed network may prove advantageous. We perform sample size calculations for sequential and non-sequential statistical studies aimed at comparing the incidence of hepatotoxicity following initiation of two newly licensed therapies for homozygous familial hypercholesterolemia. We calculate the sample size savings ratio, or the proportion of sample size saved if one conducted a sequential study as compared to a non-sequential study. Then, using models to describe the adoption and utilization of these therapies, we simulate when these sample sizes are attainable in calendar years. We then calculate the analytic calendar time savings ratio, analogous to the sample size savings ratio. We repeat these analyses for numerous scenarios. Sequential analyses detect effect sizes earlier or at the same time as non-sequential analyses. The most substantial potential savings occur when the market share is more imbalanced (i.e., 90% for therapy A) and the effect size is closest to the null hypothesis. However, due to low exposure prevalence, these savings are difficult to realize within the 30-year time frame of this simulation for scenarios in which the outcome of interest occurs at or more frequently than one event/100 person-years. We illustrate a process to assess whether sequential statistical analyses of registry data performed via distributed networks may prove a worthwhile infrastructure investment for pharmacovigilance.
Comparison of Sequential Drug Release in Vitro and in Vivo
Sundararaj, Sharath C.; Al-Sabbagh, Mohanad; Rabek, Cheryl L.; Dziubla, Thomas D.; Thomas, Mark V.; Puleo, David A.
2015-01-01
Development of drug delivery devices typically involves characterizing in vitro release performance with the inherent assumption that this will closely approximate in vivo performance. Yet, as delivery devices become more complex, for instance with a sequential drug release pattern, it is important to confirm that in vivo properties correlate with the expected “programming” achieved in vitro. In this work, a systematic comparison between in vitro and in vivo biomaterial erosion and sequential release was performed for a multilayered association polymer system comprising cellulose acetate phthalate and Pluronic F-127. After assessing the materials during incubation in phosphate-buffered saline, devices were implanted supracalvarially in rats. Devices with two different doses and with different erosion rates were harvested at increasing times post-implantation, and the in vivo thickness loss, mass loss, and the drug release profiles were compared with their in vitro counterparts. The sequential release of four different drugs observed in vitro was successfully translated to in vivo conditions. Results suggest, however, that the total erosion time of the devices was longer and release rates of the four drugs were different, with drugs initially released more quickly and then more slowly in vivo. Whereas many comparative studies of in vitro and in vivo drug release from biodegradable polymers involved a single drug, the present research demonstrated that sequential release of four drugs can be maintained following implantation. PMID:26111338
Carretti, Barbara; Lanfranchi, Silvia; Mammarella, Irene C
2013-01-01
Earlier research showed that visuospatial working memory (VSWM) is better preserved in Down syndrome (DS) than verbal WM. Some differences emerged, however, when VSWM performance was broken down into its various components, and more recent studies revealed that the spatial-simultaneous component of VSWM is more impaired than the spatial-sequential one. The difficulty of managing more than one item at a time is also evident when the information to be recalled is structured. To further analyze this issue, we investigated the advantage of material being structured in spatial-simultaneous and spatial-sequential tasks by comparing the performance of a group of individuals with DS and a group of typically-developing children matched for mental age. Both groups were presented with VSWM tasks in which both the presentation format (simultaneous vs. sequential) and the type of configuration (pattern vs. random) were manipulated. Findings indicated that individuals with DS took less advantage of the pattern configuration in the spatial-simultaneous task than TD children; in contrast, the two groups' performance did not differ in the pattern configuration of the spatial-sequential task. Taken together, these results confirmed difficulties relating to the spatial-simultaneous component of VSWM in individuals with DS, supporting the importance of distinguishing between different components within this system. The findings are discussed in terms of factors influencing this specific deficit. Copyright © 2012 Elsevier Ltd. All rights reserved.
Sequential Nonlinear Learning for Distributed Multiagent Systems via Extreme Learning Machines.
Vanli, Nuri Denizcan; Sayin, Muhammed O; Delibalta, Ibrahim; Kozat, Suleyman Serdar
2017-03-01
We study online nonlinear learning over distributed multiagent systems, where each agent employs a single hidden layer feedforward neural network (SLFN) structure to sequentially minimize arbitrary loss functions. In particular, each agent trains its own SLFN using only the data that is revealed to itself. On the other hand, the aim of the multiagent system is to train the SLFN at each agent as well as the optimal centralized batch SLFN that has access to all the data, by exchanging information between neighboring agents. We address this problem by introducing a distributed subgradient-based extreme learning machine algorithm. The proposed algorithm provides guaranteed upper bounds on the performance of the SLFN at each agent and shows that each of these individual SLFNs asymptotically achieves the performance of the optimal centralized batch SLFN. Our performance guarantees explicitly distinguish the effects of data- and network-dependent parameters on the convergence rate of the proposed algorithm. The experimental results illustrate that the proposed algorithm achieves the oracle performance significantly faster than the state-of-the-art methods in the machine learning and signal processing literature. Hence, the proposed method is highly appealing for the applications involving big data.
Marchand-Krynski, Marie-Ève; Bélanger, Anne-Marie; Morin-Moncet, Olivier; Beauchamp, Miriam H; Leonard, Gabriel
2018-01-01
This study examined cognitive predictors of sequential motor skills in 215 children with dyslexia and/or attention deficit/hyperactivity disorder (ADHD). Visual working memory and math fluency abilities contributed significantly to performance of sequential motor abilities in children with dyslexia (N = 67), ADHD (N = 66) and those with a comorbid diagnosis (N = 82), generally without differentiation between groups. In addition, primary diagnostic features of each disorder, such as reading and inattention, did not contribute to the variance in motor skill performance of these children. The results support a unifying framework of motor impairment in children with neurodevelopmental disorders such as dyslexia and ADHD.
Effect of metaphorical verbal instruction on modeling of sequential dance skills by young children.
Sawada, Misako; Mori, Shiro; Ishii, Motonobu
2002-12-01
Metaphorical verbal instruction was compared to specific verbal instruction about movement in the modeling of sequential dance skills by young children. Two groups of participants (Younger, mean age 5:3 yr., n = 30: Older, mean age 6:2 yr., n = 30) were randomly assigned to conditions in a 2 (sex) x 2 (age [Younger and Older]) x 3 (verbal instruction [Metaphorical, Movement-relevant, and None]) factorial design. Order scores were calculated for both performance and recognition tests, comprising five acquisition trials and two retention trials after 24 hr., respectively. Analysis of variance indicated that the group given metaphorical instruction performed better than the other two instructions for both younger and older children. The results suggest that metaphorical verbal instruction aids the recognition and performance of sequential dance skills in young children.
LaRC-RP41: A Tough, High-Performance Composite Matrix
NASA Technical Reports Server (NTRS)
Pater, Ruth H.; Johnston, Norman J.; Smith, Ricky E.; Snoha, John J.; Gautreaux, Carol R.; Reddy, Rakasi M.
1991-01-01
New polymer exhibits increased toughness and resistance to microcracking. Cross-linking PMR-15 and linear LaRC-TPI combined to provide sequential semi-2-IPN designated as LaRC-RP41. Synthesized from PMR-15 imide prepolymer undergoing cross-linking in immediate presence of LaRC-TPI polyamic acid, also undergoing simultaneous imidization and linear chain extension. Potentially high-temperature matrix resin, adhesive, and molding resin. Applications include automobiles, electronics, aircraft, and aerospace structures.
NASA Astrophysics Data System (ADS)
Erdal, Daniel; Cirpka, Olaf A.
2017-04-01
Regional groundwater flow strongly depends on groundwater recharge and hydraulic conductivity. While conductivity is a spatially variable field, recharge can vary in both space and time. None of the two fields can be reliably observed on larger scales, and their estimation from other sparse data sets is an open topic. Further, common hydraulic-head observations may not suffice to constrain both fields simultaneously. In the current work we use the Ensemble Kalman filter to estimate spatially variable conductivity, spatiotemporally variable recharge and porosity for a synthetic phreatic aquifer. We use transient hydraulic-head and one spatially distributed set of environmental tracer observations to constrain the estimation. As environmental tracers generally reside for a long time in an aquifer, they require long simulation times and carries a long memory that makes them highly unsuitable for use in a sequential framework. Therefore, in this work we use the environmental tracer information to precondition the initial ensemble of recharge and conductivities, before starting the sequential filter. Thereby, we aim at improving the performance of the sequential filter by limiting the range of the recharge to values similar to the long-term annual recharge means and by creating an initial ensemble of conductivities that show similar pattern and values to the true field. The sequential filter is then used to further improve the parameters and to estimate the short term temporal behavior as well as the temporally evolving head field needed for short term predictions within the aquifer. For a virtual reality covering a subsection of the river Neckar it is shown that the use of environmental tracers can improve the performance of the filter. Results using the EnKF with and without this preconditioned initial ensemble are evaluated and discussed.
Multi-GPU maximum entropy image synthesis for radio astronomy
NASA Astrophysics Data System (ADS)
Cárcamo, M.; Román, P. E.; Casassus, S.; Moral, V.; Rannou, F. R.
2018-01-01
The maximum entropy method (MEM) is a well known deconvolution technique in radio-interferometry. This method solves a non-linear optimization problem with an entropy regularization term. Other heuristics such as CLEAN are faster but highly user dependent. Nevertheless, MEM has the following advantages: it is unsupervised, it has a statistical basis, it has a better resolution and better image quality under certain conditions. This work presents a high performance GPU version of non-gridding MEM, which is tested using real and simulated data. We propose a single-GPU and a multi-GPU implementation for single and multi-spectral data, respectively. We also make use of the Peer-to-Peer and Unified Virtual Addressing features of newer GPUs which allows to exploit transparently and efficiently multiple GPUs. Several ALMA data sets are used to demonstrate the effectiveness in imaging and to evaluate GPU performance. The results show that a speedup from 1000 to 5000 times faster than a sequential version can be achieved, depending on data and image size. This allows to reconstruct the HD142527 CO(6-5) short baseline data set in 2.1 min, instead of 2.5 days that takes a sequential version on CPU.
Spatial versus sequential correlations for random access coding
NASA Astrophysics Data System (ADS)
Tavakoli, Armin; Marques, Breno; Pawłowski, Marcin; Bourennane, Mohamed
2016-03-01
Random access codes are important for a wide range of applications in quantum information. However, their implementation with quantum theory can be made in two very different ways: (i) by distributing data with strong spatial correlations violating a Bell inequality or (ii) using quantum communication channels to create stronger-than-classical sequential correlations between state preparation and measurement outcome. Here we study this duality of the quantum realization. We present a family of Bell inequalities tailored to the task at hand and study their quantum violations. Remarkably, we show that the use of spatial and sequential quantum correlations imposes different limitations on the performance of quantum random access codes: Sequential correlations can outperform spatial correlations. We discuss the physics behind the observed discrepancy between spatial and sequential quantum correlations.
Lin, Chung-Ho; Lerch, Robert N.; Thurman, E. Michael; Garrett , Harold E.; George, Milon F.
2002-01-01
Balance (isoxaflutole, IXF) belongs to a new family of herbicides referred to as isoxazoles. IXF has a very short soil half-life (<24 h), degrading to a biologically active diketonitrile (DKN) metabolite that is more polar and considerably more stable. Further degradation of the DKN metabolite produces a nonbiologically active benzoic acid (BA) metabolite. Analytical methods using solid phase extraction followed by high-performance liquid chromatography−UV (HPLC-UV) or high-performance liquid chromatography−mass spectrometry (HPLC-MS) were developed for the analysis of IXF and its metabolites in distilled deionized water and ground water samples. To successfully detect and quantify the BA metabolite by HPLC-UV from ground water samples, a sequential elution scheme was necessary. Using HPLC-UV, the mean recoveries from sequential elution of the parent and its two metabolites from fortified ground water samples ranged from 68.6 to 101.4%. For HPLC-MS, solid phase extraction of ground water samples was performed using a polystyrene divinylbenzene polymer resin. The mean HPLC-MS recoveries of the three compounds from ground water samples spiked at 0.05−2 μg/L ranged from 100.9 to 110.3%. The limits of quantitation for HPLC-UV are approximately 150 ng/L for IXF, 100 ng/L for DKN, and 250 ng/L for BA. The limit of quantitation by HPLC-MS is 50 ng/L for each compound. The methods developed in this work can be applied to determine the transport and fate of Balance in the environment.
Lin, Chung-Ho; Lerch, Robert N; Thurman, E Michael; Garrett, Harold E; George, Milon F
2002-10-09
Balance (isoxaflutole, IXF) belongs to a new family of herbicides referred to as isoxazoles. IXF has a very short soil half-life (<24 h), degrading to a biologically active diketonitrile (DKN) metabolite that is more polar and considerably more stable. Further degradation of the DKN metabolite produces a nonbiologically active benzoic acid (BA) metabolite. Analytical methods using solid phase extraction followed by high-performance liquid chromatography-UV (HPLC-UV) or high-performance liquid chromatography-mass spectrometry (HPLC-MS) were developed for the analysis of IXF and its metabolites in distilled deionized water and ground water samples. To successfully detect and quantify the BA metabolite by HPLC-UV from ground water samples, a sequential elution scheme was necessary. Using HPLC-UV, the mean recoveries from sequential elution of the parent and its two metabolites from fortified ground water samples ranged from 68.6 to 101.4%. For HPLC-MS, solid phase extraction of ground water samples was performed using a polystyrene divinylbenzene polymer resin. The mean HPLC-MS recoveries of the three compounds from ground water samples spiked at 0.05-2 microg/L ranged from 100.9 to 110.3%. The limits of quantitation for HPLC-UV are approximately 150 ng/L for IXF, 100 ng/L for DKN, and 250 ng/L for BA. The limit of quantitation by HPLC-MS is 50 ng/L for each compound. The methods developed in this work can be applied to determine the transport and fate of Balance in the environment.
Fractionation of sheep cheese whey by a scalable method to sequentially isolate bioactive proteins.
Pilbrow, Jodi; Bekhit, Alaa El-Din A; Carne, Alan
2016-07-15
This study reports a procedure for the simultaneous purification of glyco(caseino)macropeptide, immunoglobulin, lactoperoxidase, lactoferrin, α-lactalbumin and β-lactoglobulin from sheep cheese sweet whey, an under-utilized by-product of cheese manufacture generated by an emerging sheep dairy industry in New Zealand. These proteins have recognized value in the nutrition, biomedical and health-promoting supplements industries. A sequential fractionation procedure using economical anion and cation exchange chromatography on HiTrap resins was evaluated. The whey protein fractionation is performed under mild conditions, requires only the adjustment of pH between ion exchange chromatography steps, does not require buffer exchange and uses minimal amounts of chemicals. The purity of the whey protein fractions generated were analyzed by reversed phase-high performance liquid chromatography and the identity of the proteins was confirmed by mass spectrometry. This scalable procedure demonstrates that several proteins of recognized value can be fractionated in reasonable yield and purity from sheep cheese whey in one streamlined process. Copyright © 2016 Elsevier Ltd. All rights reserved.
Three- α particle correlations in quasi-projectile decay in 12C + 24Mg collisions at 35A MeV
NASA Astrophysics Data System (ADS)
Quattrocchi, L.; Acosta, L.; Amorini, F.; Anzalone, A.; Auditore, L.; Berceanu, I.; Cardella, G.; Chbihi, A.; De Filippo, E.; De Luca, S.; Dell'Aquila, D.; Francalanza, L.; Gnoffo, B.; Grzeszczuk, A.; Lanzalone, G.; Lombardo, I.; Martel, I.; Martorana, N. S.; Minniti, T.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Rizzo, F.; Rosato, E.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Veselsky, M.; Vigilante, M.
2017-11-01
Two and multi particle correlations have been studied in peripheral 12C + 24Mg collisions at 35A MeV with CHIMERA 4 π multi detector, in order to explore resonances produced in light nuclei. Correlations techniques have become a tool to explore nuclear structure properties but also to evaluate the competition between simultaneous and sequential channels in decay of light isotopes. The exploration of features such as branching ratios with respect to different decay channels (sequential vs. simultaneous) could provide information on in-medium effects on nuclear structure properties, an important perspective for research on the nuclear interaction. The performed experiment is preliminary to further studies to be performed by coupling of CHIMERA to FARCOS (Femtoscope ARray for COrrelations and Spectroscopy, FARCOS TDR available at https://drive.google.com/file/d/0B5CgGWz8LpOOc3pGTWdOcDBoWFE) array devoted to measurements of two and multi particle correlations with high energy and angular resolutions.
de Oliveira, Saulo H P; Law, Eleanor C; Shi, Jiye; Deane, Charlotte M
2018-04-01
Most current de novo structure prediction methods randomly sample protein conformations and thus require large amounts of computational resource. Here, we consider a sequential sampling strategy, building on ideas from recent experimental work which shows that many proteins fold cotranslationally. We have investigated whether a pseudo-greedy search approach, which begins sequentially from one of the termini, can improve the performance and accuracy of de novo protein structure prediction. We observed that our sequential approach converges when fewer than 20 000 decoys have been produced, fewer than commonly expected. Using our software, SAINT2, we also compared the run time and quality of models produced in a sequential fashion against a standard, non-sequential approach. Sequential prediction produces an individual decoy 1.5-2.5 times faster than non-sequential prediction. When considering the quality of the best model, sequential prediction led to a better model being produced for 31 out of 41 soluble protein validation cases and for 18 out of 24 transmembrane protein cases. Correct models (TM-Score > 0.5) were produced for 29 of these cases by the sequential mode and for only 22 by the non-sequential mode. Our comparison reveals that a sequential search strategy can be used to drastically reduce computational time of de novo protein structure prediction and improve accuracy. Data are available for download from: http://opig.stats.ox.ac.uk/resources. SAINT2 is available for download from: https://github.com/sauloho/SAINT2. saulo.deoliveira@dtc.ox.ac.uk. Supplementary data are available at Bioinformatics online.
Development of high-accuracy convection schemes for sequential solvers
NASA Technical Reports Server (NTRS)
Thakur, Siddharth; Shyy, Wei
1993-01-01
An exploration is conducted of the applicability of such high resolution schemes as TVD to the resolving of sharp flow gradients using a sequential solution approach borrowed from pressure-based algorithms. It is shown that by extending these high-resolution shock-capturing schemes to a sequential solver that treats the equations as a collection of scalar conservation equations, the speed of signal propagation in the solution has to be coordinated by assigning the local convection speed as the characteristic speed for the entire system. A higher amount of dissipation is therefore needed to eliminate oscillations near discontinuities.
NASA Astrophysics Data System (ADS)
Farooqi, Izharul H.; Basheer, Farrukh; Tiwari, Pradeepika
2017-12-01
Laboratory scale experiments were carried out to access the feasibility of sequential anaerobic/aerobic biological treatment for the biodegradation of Methylene Blue (MB) dye. Anaerobic studies were performed using anaerobic hybrid reactor (consisting of UASB and Anaerobic filter) whereas submerged aerobic fixed film reactor was used as aerobic reactor. Degradation of MB dye was attempted using neutralized acetic acid (1000 mg/L) as co-substrate. MB dye concentration was stepwise increased from 10 to 70 mg/L after reaching steady state in each dye concentration. Such a gradual increase in the dye concentration helps in the proper acclimatization of the sludge to dyes thereby avoiding the possible inhibitory effects to biological activities at high dye concentrations. The overall treatment efficiency of MB through sequential anaerobic-aerobic reactor operation was 90% at maximum attempted dye concentration of 70 mg/L. The effluent from anaerobic reactor was analysed for intermediate biodegradation products through HPLC. It was observed that catechol, quinone, amino pyrine, 1,4 diamino benzene were present. However they were absent in final effluent.
Husson, Eric; Auxenfans, Thomas; Herbaut, Mickael; Baralle, Manon; Lambertyn, Virginie; Rakotoarivonina, Harivoni; Rémond, Caroline; Sarazin, Catherine
2018-03-01
Sequential and simultaneous strategies for fractioning wheat straw were developed in combining 1-ethyl-3-methyl imidazolium acetate [C2mim][OAc], endo-xylanases from Thermobacillus xylanilyticus and commercial cellulases. After [C2mim][OAc]-pretreatment, hydrolysis catalyzed by endo-xylanases of wheat straw led to efficient xylose production with very competitive yield (97.6 ± 1.3%). Subsequent enzymatic saccharification allowed achieving a total degradation of cellulosic fraction (>99%). These high performances revealed an interesting complementarity of [C2mim][OAc]- and xylanase-pretreatments for increasing enzymatic digestibility of cellulosic fraction in agreement with the structural and morphological changes of wheat straw induced by each of these pretreatment steps. In addition a higher tolerance of endo-xylanases from T. xylaniliticus to [C2mim][AcO] until 30% v/v than cellulases from T. reesei was observed. Based on this property, a simultaneous strategy combining [C2mim][OAc]- and endo-xylanases as pretreatment in a one-batch produced xylose with similar yield than those obtained by the sequential strategy. Copyright © 2017 Elsevier Ltd. All rights reserved.
MSFC Skylab airlock module, volume 1. [systems design and performance
NASA Technical Reports Server (NTRS)
1974-01-01
The history and development of the Skylab Airlock Module and Payload Shroud is presented from initial concept through final design. A summary is given of the Airlock features and systems. System design and performance are presented for the Spent Stage Experiment Support Module, structure and mechanical systems, mass properties, thermal and environmental control systems, EVA/IVA suite system, electrical power system, sequential system, sequential system, and instrumentation system.
Cell adhesion monitoring of human induced pluripotent stem cell based on intrinsic molecular charges
NASA Astrophysics Data System (ADS)
Sugimoto, Haruyo; Sakata, Toshiya
2014-01-01
We have shown a simple way for real-time, quantitative, non-invasive, and non-label monitoring of human induced pluripotent stem (iPS) cell adhesion by use of a biologically coupled-gate field effect transistor (bio-FET), which is based on detection of molecular charges at cell membrane. The electrical behavior revealed quantitatively the electrical contacts of integrin-receptor at the cell membrane with RGDS peptide immobilized at the gate sensing surface, because that binding site was based on cationic α chain of integrin. The platform based on the bio-FET would provide substantial information to evaluate cell/material bio-interface and elucidate biding mechanism of adhesion molecules, which could not be interpreted by microscopic observation.
Monolithic graphene transistor biointerface.
Nam, SungWoo; Lee, Mi-Sun; Park, Jang-Ung
2012-01-01
We report monolithic integration of graphene and graphite for all-carbon integrated bioelectronics. First, we demonstrate that the electrical properties of graphene and graphite can be modulated by controlling the number of graphene layers, and such capabilities allow graphene to be used as active channels and graphite as metallic interconnects for all-carbon bioelectronics. Furthermore, we show that monolithic graphene-graphite devices exhibit mechanical flexibility and robustness while their electrical responses are not perturbed by mechanical deformation, demonstrating their unique electromechanical properties. Chemical sensing capability of all-carbon integrated bioelectronics is manifested in real-time, complementary pH detection. These unique capabilities of our monolithic graphene-graphite bioelectronics could be exploited in chemical and biological detection and conformal interface with biological systems in the future.
Signorelli, Mauro; Lissoni, Andrea Alberto; De Ponti, Elena; Grassi, Tommaso; Ponti, Serena
2015-01-01
Objective Evaluation of the impact of sequential chemoradiotherapy in high risk endometrial cancer (EC). Methods Two hundred fifty-four women with stage IB grade 3, II and III EC (2009 FIGO staging), were included in this retrospective study. Results Stage I, II, and III was 24%, 28.7%, and 47.3%, respectively. Grade 3 tumor was 53.2% and 71.3% had deep myometrial invasion. One hundred sixty-five women (65%) underwent pelvic (+/- aortic) lymphadenectomy and 58 (22.8%) had nodal metastases. Ninety-eight women (38.6%) underwent radiotherapy, 59 (23.2%) chemotherapy, 42 (16.5%) sequential chemoradiotherapy, and 55 (21.7%) were only observed. After a median follow-up of 101 months, 78 women (30.7%) relapsed and 91 women (35.8%) died. Sequential chemoradiotherapy improved survival rates in women who did not undergo nodal evaluation (disease-free survival [DFS], p=0.040; overall survival [OS], p=0.024) or pelvic (+/- aortic) lymphadenectomy (DFS, p=0.008; OS, p=0.021). Sequential chemoradiotherapy improved both DFS (p=0.015) and OS (p=0.014) in stage III, while only a trend was found for DFS (p=0.210) and OS (p=0.102) in stage I-II EC. In the multivariate analysis, only age (≤65 years) and sequential chemoradiotherapy were statistically related to the prognosis. Conclusion Sequential chemoradiotherapy improves survival rates in high risk EC compared with chemotherapy or radiotherapy alone, in particular in stage III. PMID:26197768
NASA Astrophysics Data System (ADS)
Nystrøm, G. M.; Ottosen, L. M.; Villumsen, A.
2003-05-01
In this work sequential extraction is performed with harbour sediment in order to evaluate the electrodialytic remediation potential for harbour sediments. Sequential extraction was performed on a sample of Norwegian harbour sediment; with the original sediment and after the sediment was treated with acid. The results from the sequential extraction show that 75% Zn and Pb and about 50% Cu are found in the most mobile phases in the original sediment and more than 90% Zn and Pb and 75% Cu are found in the most mobile phase in the sediment treated with acid. Electrodialytic remediation experiments were made. The method uses a low direct current as cleaning agent, removing the heavy metals towards the anode and cathode according to the charge of the heavy metals in the electric field. The electrodialytic experiments show that up to 50% Cu, 85% Zn and 60% Pb can be removed after 20 days. Thus, there is still a potential for a higher removal, with some changes in the experimental set-up and longer remediation time. The experiments show that thc use of sequential extraction can be used to predict the electrodialytic remediation potential for harbour sediments.
Yoda, Satoshi; Lin, Jessica J; Lawrence, Michael S; Burke, Benjamin J; Friboulet, Luc; Langenbucher, Adam; Dardaei, Leila; Prutisto-Chang, Kylie; Dagogo-Jack, Ibiayi; Timofeevski, Sergei; Hubbeling, Harper; Gainor, Justin F; Ferris, Lorin A; Riley, Amanda K; Kattermann, Krystina E; Timonina, Daria; Heist, Rebecca S; Iafrate, A John; Benes, Cyril H; Lennerz, Jochen K; Mino-Kenudson, Mari; Engelman, Jeffrey A; Johnson, Ted W; Hata, Aaron N; Shaw, Alice T
2018-06-01
The cornerstone of treatment for advanced ALK-positive lung cancer is sequential therapy with increasingly potent and selective ALK inhibitors. The third-generation ALK inhibitor lorlatinib has demonstrated clinical activity in patients who failed previous ALK inhibitors. To define the spectrum of ALK mutations that confer lorlatinib resistance, we performed accelerated mutagenesis screening of Ba/F3 cells expressing EML4-ALK. Under comparable conditions, N -ethyl- N -nitrosourea (ENU) mutagenesis generated numerous crizotinib-resistant but no lorlatinib-resistant clones harboring single ALK mutations. In similar screens with EML4-ALK containing single ALK resistance mutations, numerous lorlatinib-resistant clones emerged harboring compound ALK mutations. To determine the clinical relevance of these mutations, we analyzed repeat biopsies from lorlatinib-resistant patients. Seven of 20 samples (35%) harbored compound ALK mutations, including two identified in the ENU screen. Whole-exome sequencing in three cases confirmed the stepwise accumulation of ALK mutations during sequential treatment. These results suggest that sequential ALK inhibitors can foster the emergence of compound ALK mutations, identification of which is critical to informing drug design and developing effective therapeutic strategies. Significance: Treatment with sequential first-, second-, and third-generation ALK inhibitors can select for compound ALK mutations that confer high-level resistance to ALK-targeted therapies. A more efficacious long-term strategy may be up-front treatment with a third-generation ALK inhibitor to prevent the emergence of on-target resistance. Cancer Discov; 8(6); 714-29. ©2018 AACR. This article is highlighted in the In This Issue feature, p. 663 . ©2018 American Association for Cancer Research.
Harari, Colin M.; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T.; Lubner, Meghan G.; Hinshaw, J. Louis; Ziemlewicz, Timothy
2016-01-01
Purpose To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. Materials and Methods All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. Results On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. Conclusion The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015 PMID:26133361
Sequential Bayesian geoacoustic inversion for mobile and compact source-receiver configuration.
Carrière, Olivier; Hermand, Jean-Pierre
2012-04-01
Geoacoustic characterization of wide areas through inversion requires easily deployable configurations including free-drifting platforms, underwater gliders and autonomous vehicles, typically performing repeated transmissions during their course. In this paper, the inverse problem is formulated as sequential Bayesian filtering to take advantage of repeated transmission measurements. Nonlinear Kalman filters implement a random-walk model for geometry and environment and an acoustic propagation code in the measurement model. Data from MREA/BP07 sea trials are tested consisting of multitone and frequency-modulated signals (bands: 0.25-0.8 and 0.8-1.6 kHz) received on a shallow vertical array of four hydrophones 5-m spaced drifting over 0.7-1.6 km range. Space- and time-coherent processing are applied to the respective signal types. Kalman filter outputs are compared to a sequence of global optimizations performed independently on each received signal. For both signal types, the sequential approach is more accurate but also more efficient. Due to frequency diversity, the processing of modulated signals produces a more stable tracking. Although an extended Kalman filter provides comparable estimates of the tracked parameters, the ensemble Kalman filter is necessary to properly assess uncertainty. In spite of mild range dependence and simplified bottom model, all tracked geoacoustic parameters are consistent with high-resolution seismic profiling, core logging P-wave velocity, and previous inversion results with fixed geometries.
Di Paolo, Antonello; Orlandi, Paola; Di Desidero, Teresa; Danesi, Romano; Bocci, Guido
2017-08-07
The combination of folinate salts to 5-fluoruracil (5-FU)-based schedules is an established clinical routine in the landscape of colorectal cancer treatment. The aim of this study was to investigate the pharmacological differences between the sequential administration of folinate salts (1 h before, as in clinical routine) followed by 5-FU and the simultaneous administration of both drugs. Proliferation and apoptotic assays were performed on human colon cancer cells exposed to 5-FU, calcium (CaLV), or disodium (NaLV) levofolinate or their simultaneous and sequential combination for 24 and 72 h. TYMS and SLC19A1 gene expression was performed with real-time PCR. In vivo experiments were performed in xenografted nude mice, which were treated with 5-FU escalating doses and CaLV or NaLV alone or in simultaneous and sequential combination. The simultaneous combination of folinate salts and 5-FU was synergistic (NaLV) or additive (CaLV) in a 24-h treatment in both cell lines. In contrast, the sequential combination of both folinate salts and 5-FU was antagonistic at 24 and 72 h. The simultaneous combination of 5-FU and NaLV or CaLV inhibited TYMS gene expression at 24 h, whereas the sequential combination reduced SLC19A1 gene expression. In vivo experiments confirmed the enhanced antitumor activity of the 5-FU + NaLV simultaneous combination with a good toxicity profile, whereas the sequential combination with CaLV failed to potentiate 5-FU activity. In conclusion, only the simultaneous, but not the consecutive, in vitro and in vivo combination of 5-FU and both folinate salt formulations potentiated the antiproliferative effects of the drugs.
NASA Astrophysics Data System (ADS)
Heisler, Morgan; Lee, Sieun; Mammo, Zaid; Jian, Yifan; Ju, Myeong Jin; Miao, Dongkai; Raposo, Eric; Wahl, Daniel J.; Merkur, Andrew; Navajas, Eduardo; Balaratnasingam, Chandrakumar; Beg, Mirza Faisal; Sarunic, Marinko V.
2017-02-01
High quality visualization of the retinal microvasculature can improve our understanding of the onset and development of retinal vascular diseases, which are a major cause of visual morbidity and are increasing in prevalence. Optical Coherence Tomography Angiography (OCT-A) images are acquired over multiple seconds and are particularly susceptible to motion artifacts, which are more prevalent when imaging patients with pathology whose ability to fixate is limited. The acquisition of multiple OCT-A images sequentially can be performed for the purpose of removing motion artifact and increasing the contrast of the vascular network through averaging. Due to the motion artifacts, a robust registration pipeline is needed before feature preserving image averaging can be performed. In this report, we present a novel method for a GPU-accelerated pipeline for acquisition, processing, segmentation, and registration of multiple, sequentially acquired OCT-A images to correct for the motion artifacts in individual images for the purpose of averaging. High performance computing, blending CPU and GPU, was introduced to accelerate processing in order to provide high quality visualization of the retinal microvasculature and to enable a more accurate quantitative analysis in a clinically useful time frame. Specifically, image discontinuities caused by rapid micro-saccadic movements and image warping due to smoother reflex movements were corrected by strip-wise affine registration estimated using Scale Invariant Feature Transform (SIFT) keypoints and subsequent local similarity-based non-rigid registration. These techniques improve the image quality, increasing the value for clinical diagnosis and increasing the range of patients for whom high quality OCT-A images can be acquired.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pullum, Laura L; Hobson, Tanner C
We examine the use of electronic healthcare reimbursement claims (EHRC) for analyzing healthcare delivery and practice patterns across the United States (US). By analyzing over 1 billion EHRCs, we track patterns of clinical procedures administered to patients with heart disease (HD) using sequential pattern mining algorithms. Our analyses reveal that the clinical procedures performed on HD patients are highly varied leading up to and after the primary diagnosis. The discovered clinical procedure sequences reveal significant differences in the overall costs incurred across different parts of the US, indicating significant heterogeneity in treating HD patients. We show that a data-driven approachmore » to understand patient specific clinical trajectories constructed from EHRC can provide quantitative insights into how to better manage and treat patients.« less
A comprehensive review on nano-molybdenum disulfide/DNA interfaces as emerging biosensing platforms.
Kukkar, Manil; Mohanta, Girish C; Tuteja, Satish K; Kumar, Parveen; Bhadwal, Akhshay Singh; Samaddar, Pallabi; Kim, Ki-Hyun; Deep, Akash
2018-06-01
The development of nucleic acid-based portable platforms for the real-time analysis of diseases has attracted considerable scientific and commercial interest. Recently, 2D layered molybdenum sulfide (2D MoS 2 from here on) nanosheets have shown great potential for the development of next-generation platforms for efficient signal transduction. Through combination with DNA as a biorecognition medium, MoS 2 nanostructures have opened new opportunities to design and construct highly sensitive, specific, and commercially viable sensing devices. The use of specific short ssDNA sequences like aptamers has been proven to bind well with the unique transduction properties of 2D MoS 2 nanosheets to realize aptasensing devices. Such sensors can be operated on the principles of fluorescence, electro-cheumuluminescence, and electrochemistry with many advantageous features (e.g., robust biointerfacing through various conjugation chemistries, facile sensor assembly, high stability with regard to temperature/pH, and high affinity to target). This review encompasses the state of the art information on various design tactics and working principles of MoS 2 /DNA sensor technology which is emerging as one of the most sought-after and valuable fields with the advent of nucleic acid inspired devices. To help achieve a new milestone in biosensing applications, great potential of this emerging technique is described further with regard to sensitivity, specificity, operational convenience, and versatility. Copyright © 2018 Elsevier B.V. All rights reserved.
Ku, Yixuan; Zhao, Di; Hao, Ning; Hu, Yi; Bodner, Mark; Zhou, Yong-Di
2015-01-01
Both monkey neurophysiological and human EEG studies have shown that association cortices, as well as primary sensory cortical areas, play an essential role in sequential neural processes underlying cross-modal working memory. The present study aims to further examine causal and sequential roles of the primary sensory cortex and association cortex in cross-modal working memory. Individual MRI-based single-pulse transcranial magnetic stimulation (spTMS) was applied to bilateral primary somatosensory cortices (SI) and the contralateral posterior parietal cortex (PPC), while participants were performing a tactile-visual cross-modal delayed matching-to-sample task. Time points of spTMS were 300 ms, 600 ms, 900 ms after the onset of the tactile sample stimulus in the task. The accuracy of task performance and reaction time were significantly impaired when spTMS was applied to the contralateral SI at 300 ms. Significant impairment on performance accuracy was also observed when the contralateral PPC was stimulated at 600 ms. SI and PPC play sequential and distinct roles in neural processes of cross-modal associations and working memory. Copyright © 2015 Elsevier Inc. All rights reserved.
Unsteady, one-dimensional gas dynamics computations using a TVD type sequential solver
NASA Technical Reports Server (NTRS)
Thakur, Siddharth; Shyy, Wei
1992-01-01
The efficacy of high resolution convection schemes to resolve sharp gradient in unsteady, 1D flows is examined using the TVD concept based on a sequential solution algorithm. Two unsteady flow problems are considered which include the problem involving the interaction of the various waves in a shock tube with closed reflecting ends and the problem involving the unsteady gas dynamics in a tube with closed ends subject to an initial pressure perturbation. It is concluded that high accuracy convection schemes in a sequential solution framework are capable of resolving discontinuities in unsteady flows involving complex gas dynamics. However, a sufficient amount of dissipation is required to suppress oscillations near discontinuities in the sequential approach, which leads to smearing of the solution profiles.
Lemons, B; Khaing, H; Ward, A; Thakur, P
2018-06-01
A new sequential separation method for the determination of polonium and actinides (Pu, Am and U) in drinking water samples has been developed that can be used for emergency response or routine water analyses. For the first time, the application of TEVA chromatography column in the sequential separation of polonium and plutonium has been studied. This method utilizes a rapid Fe +3 co-precipitation step to remove matrix interferences, followed by plutonium oxidation state adjustment to Pu 4+ and an incubation period of ~ 1 h at 50-60 °C to allow Po 2+ to oxidize to Po 4+ . The polonium and plutonium were then separated on a TEVA column, while separation of americium from uranium was performed on a TRU column. After separation, polonium was micro-precipitated with copper sulfide (CuS), while actinides were micro co-precipitated using neodymium fluoride (NdF 3 ) for counting by the alpha spectrometry. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. The efficiency and reliability of the procedures were tested by using spiked samples. The effect of several transition metals (Cu 2+ , Pb 2+ , Fe 3+ , Fe 2+ , and Ni 2+ ) on the performance of this method were also assessed to evaluate the potential matrix effects. Studies indicate that presence of up to 25 mg of these cations in the samples had no adverse effect on the recovery or the resolution of polonium alpha peaks. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sadeque, Farig; Xu, Dongfang; Bethard, Steven
2017-01-01
The 2017 CLEF eRisk pilot task focuses on automatically detecting depression as early as possible from a users’ posts to Reddit. In this paper we present the techniques employed for the University of Arizona team’s participation in this early risk detection shared task. We leveraged external information beyond the small training set, including a preexisting depression lexicon and concepts from the Unified Medical Language System as features. For prediction, we used both sequential (recurrent neural network) and non-sequential (support vector machine) models. Our models perform decently on the test data, and the recurrent neural models perform better than the non-sequential support vector machines while using the same feature sets. PMID:29075167
Shin, Yong-Uk; Yoo, Ha-Young; Kim, Seonghun; Chung, Kyung-Mi; Park, Yong-Gyun; Hwang, Kwang-Hyun; Hong, Seok Won; Park, Hyunwoong; Cho, Kangwoo; Lee, Jaesang
2017-09-19
A two-stage sequential electro-Fenton (E-Fenton) oxidation followed by electrochemical chlorination (EC) was demonstrated to concomitantly treat high concentrations of organic carbon and ammonium nitrogen (NH 4 + -N) in real anaerobically digested food wastewater (ADFW). The anodic Fenton process caused the rapid mineralization of phenol as a model substrate through the production of hydroxyl radical as the main oxidant. The electrochemical oxidation of NH 4 + by a dimensionally stable anode (DSA) resulted in temporal concentration profiles of combined and free chlorine species that were analogous to those during the conventional breakpoint chlorination of NH 4 + . Together with the minimal production of nitrate, this confirmed that the conversion of NH 4 + to nitrogen gas was electrochemically achievable. The monitoring of treatment performance with varying key parameters (e.g., current density, H 2 O 2 feeding rate, pH, NaCl loading, and DSA type) led to the optimization of two component systems. The comparative evaluation of two sequentially combined systems (i.e., the E-Fenton-EC system versus the EC-E-Fenton system) using the mixture of phenol and NH 4 + under the predetermined optimal conditions suggested the superiority of the E-Fenton-EC system in terms of treatment efficiency and energy consumption. Finally, the sequential E-Fenton-EC process effectively mineralized organic carbon and decomposed NH 4 + -N in the real ADFW without external supply of NaCl.
von Helversen, Bettina; Mata, Rui
2012-12-01
We investigated the contribution of cognitive ability and affect to age differences in sequential decision making by asking younger and older adults to shop for items in a computerized sequential decision-making task. Older adults performed poorly compared to younger adults partly due to searching too few options. An analysis of the decision process with a formal model suggested that older adults set lower thresholds for accepting an option than younger participants. Further analyses suggested that positive affect, but not fluid abilities, was related to search in the sequential decision task. A second study that manipulated affect in younger adults supported the causal role of affect: Increased positive affect lowered the initial threshold for accepting an attractive option. In sum, our results suggest that positive affect is a key factor determining search in sequential decision making. Consequently, increased positive affect in older age may contribute to poorer sequential decisions by leading to insufficient search. 2013 APA, all rights reserved
Analysis of Optimal Sequential State Discrimination for Linearly Independent Pure Quantum States.
Namkung, Min; Kwon, Younghun
2018-04-25
Recently, J. A. Bergou et al. proposed sequential state discrimination as a new quantum state discrimination scheme. In the scheme, by the successful sequential discrimination of a qubit state, receivers Bob and Charlie can share the information of the qubit prepared by a sender Alice. A merit of the scheme is that a quantum channel is established between Bob and Charlie, but a classical communication is not allowed. In this report, we present a method for extending the original sequential state discrimination of two qubit states to a scheme of N linearly independent pure quantum states. Specifically, we obtain the conditions for the sequential state discrimination of N = 3 pure quantum states. We can analytically provide conditions when there is a special symmetry among N = 3 linearly independent pure quantum states. Additionally, we show that the scenario proposed in this study can be applied to quantum key distribution. Furthermore, we show that the sequential state discrimination of three qutrit states performs better than the strategy of probabilistic quantum cloning.
ERIC Educational Resources Information Center
Allen, Mark H.; And Others
1991-01-01
This study found that a group of 20 children (ages 6-12) with autism and a group of 20 children with developmental receptive language disorder both manifested a relative sequential processing deficit. The groups did not differ significantly on overall sequential and simultaneous processing capabilities relative to their degree of language…
A multi-stage drop-the-losers design for multi-arm clinical trials.
Wason, James; Stallard, Nigel; Bowden, Jack; Jennison, Christopher
2017-02-01
Multi-arm multi-stage trials can improve the efficiency of the drug development process when multiple new treatments are available for testing. A group-sequential approach can be used in order to design multi-arm multi-stage trials, using an extension to Dunnett's multiple-testing procedure. The actual sample size used in such a trial is a random variable that has high variability. This can cause problems when applying for funding as the cost will also be generally highly variable. This motivates a type of design that provides the efficiency advantages of a group-sequential multi-arm multi-stage design, but has a fixed sample size. One such design is the two-stage drop-the-losers design, in which a number of experimental treatments, and a control treatment, are assessed at a prescheduled interim analysis. The best-performing experimental treatment and the control treatment then continue to a second stage. In this paper, we discuss extending this design to have more than two stages, which is shown to considerably reduce the sample size required. We also compare the resulting sample size requirements to the sample size distribution of analogous group-sequential multi-arm multi-stage designs. The sample size required for a multi-stage drop-the-losers design is usually higher than, but close to, the median sample size of a group-sequential multi-arm multi-stage trial. In many practical scenarios, the disadvantage of a slight loss in average efficiency would be overcome by the huge advantage of a fixed sample size. We assess the impact of delay between recruitment and assessment as well as unknown variance on the drop-the-losers designs.
Comparison of Performance of Eight-Year-Old Children on Three Auditory Sequential Memory Tests.
ERIC Educational Resources Information Center
Chermak, Gail D.; O'Connell, Vickie I.
1981-01-01
Twenty normal children were administered three tests of auditory sequential memory. A Pearson product-moment correlation of .50 and coefficients of determination showed all but one relationship to be nonsignificant and predictability between pairs of scores to be poor. (Author)
THRESHOLD ELEMENTS AND THE DESIGN OF SEQUENTIAL SWITCHING NETWORKS.
The report covers research performed from March 1966 to March 1967. The major topics treated are: (1) methods for finding weight- threshold vectors...that realize a given switching function in multi- threshold linear logic; (2) synthesis of sequential machines by means of shift registers and simple
Nakashima, Ryoichi; Komori, Yuya; Maeda, Eriko; Yoshikawa, Takeharu; Yokosawa, Kazuhiko
2016-01-01
Although viewing multiple stacks of medical images presented on a display is a relatively new but useful medical task, little is known about this task. Particularly, it is unclear how radiologists search for lesions in this type of image reading. When viewing cluttered and dynamic displays, continuous motion itself does not capture attention. Thus, it is effective for the target detection that observers' attention is captured by the onset signal of a suddenly appearing target among the continuously moving distractors (i.e., a passive viewing strategy). This can be applied to stack viewing tasks, because lesions often show up as transient signals in medical images which are sequentially presented simulating a dynamic and smoothly transforming image progression of organs. However, it is unclear whether observers can detect a target when the target appears at the beginning of a sequential presentation where the global apparent motion onset signal (i.e., signal of the initiation of the apparent motion by sequential presentation) occurs. We investigated the ability of radiologists to detect lesions during such tasks by comparing the performances of radiologists and novices. Results show that overall performance of radiologists is better than novices. Furthermore, the temporal locations of lesions in CT image sequences, i.e., when a lesion appears in an image sequence, does not affect the performance of radiologists, whereas it does affect the performance of novices. Results indicate that novices have greater difficulty in detecting a lesion appearing early than late in the image sequence. We suggest that radiologists have other mechanisms to detect lesions in medical images with little attention which novices do not have. This ability is critically important when viewing rapid sequential presentations of multiple CT images, such as stack viewing tasks.
Nakashima, Ryoichi; Komori, Yuya; Maeda, Eriko; Yoshikawa, Takeharu; Yokosawa, Kazuhiko
2016-01-01
Although viewing multiple stacks of medical images presented on a display is a relatively new but useful medical task, little is known about this task. Particularly, it is unclear how radiologists search for lesions in this type of image reading. When viewing cluttered and dynamic displays, continuous motion itself does not capture attention. Thus, it is effective for the target detection that observers' attention is captured by the onset signal of a suddenly appearing target among the continuously moving distractors (i.e., a passive viewing strategy). This can be applied to stack viewing tasks, because lesions often show up as transient signals in medical images which are sequentially presented simulating a dynamic and smoothly transforming image progression of organs. However, it is unclear whether observers can detect a target when the target appears at the beginning of a sequential presentation where the global apparent motion onset signal (i.e., signal of the initiation of the apparent motion by sequential presentation) occurs. We investigated the ability of radiologists to detect lesions during such tasks by comparing the performances of radiologists and novices. Results show that overall performance of radiologists is better than novices. Furthermore, the temporal locations of lesions in CT image sequences, i.e., when a lesion appears in an image sequence, does not affect the performance of radiologists, whereas it does affect the performance of novices. Results indicate that novices have greater difficulty in detecting a lesion appearing early than late in the image sequence. We suggest that radiologists have other mechanisms to detect lesions in medical images with little attention which novices do not have. This ability is critically important when viewing rapid sequential presentations of multiple CT images, such as stack viewing tasks. PMID:27774080
Neel, Sean T
2014-11-01
A cost analysis was performed to evaluate the effect on physicians in the United States of a transition from delayed sequential cataract surgery to immediate sequential cataract surgery. Financial and efficiency impacts of this change were evaluated to determine whether efficiency gains could offset potential reduced revenue. A cost analysis using Medicare cataract surgery volume estimates, Medicare 2012 physician cataract surgery reimbursement schedules, and estimates of potential additional office visit revenue comparing immediate sequential cataract surgery with delayed sequential cataract surgery for a single specialty ophthalmology practice in West Tennessee. This model should give an indication of the effect on physicians on a national basis. A single specialty ophthalmology practice in West Tennessee was found to have a cataract surgery revenue loss of $126,000, increased revenue from office visits of $34,449 to $106,271 (minimum and maximum offset methods), and a net loss of $19,900 to $91,700 (base case) with the conversion to immediate sequential cataract surgery. Physicians likely stand to lose financially, and this loss cannot be offset by increased patient visits under the current reimbursement system. This may result in physician resistance to converting to immediate sequential cataract surgery, gaming, and supplier-induced demand.
Learning, memory, and the role of neural network architecture.
Hermundstad, Ann M; Brown, Kevin S; Bassett, Danielle S; Carlson, Jean M
2011-06-01
The performance of information processing systems, from artificial neural networks to natural neuronal ensembles, depends heavily on the underlying system architecture. In this study, we compare the performance of parallel and layered network architectures during sequential tasks that require both acquisition and retention of information, thereby identifying tradeoffs between learning and memory processes. During the task of supervised, sequential function approximation, networks produce and adapt representations of external information. Performance is evaluated by statistically analyzing the error in these representations while varying the initial network state, the structure of the external information, and the time given to learn the information. We link performance to complexity in network architecture by characterizing local error landscape curvature. We find that variations in error landscape structure give rise to tradeoffs in performance; these include the ability of the network to maximize accuracy versus minimize inaccuracy and produce specific versus generalizable representations of information. Parallel networks generate smooth error landscapes with deep, narrow minima, enabling them to find highly specific representations given sufficient time. While accurate, however, these representations are difficult to generalize. In contrast, layered networks generate rough error landscapes with a variety of local minima, allowing them to quickly find coarse representations. Although less accurate, these representations are easily adaptable. The presence of measurable performance tradeoffs in both layered and parallel networks has implications for understanding the behavior of a wide variety of natural and artificial learning systems.
Outcomes of simultaneous resections for patients with synchronous colorectal liver metastases.
Slesser, A A P; Chand, M; Goldin, R; Brown, G; Tekkis, P P; Mudan, S
2013-12-01
The aim of this study was to determine the outcomes associated with simultaneous resections compared to patients undergoing sequential resections for synchronous colorectal liver metastases. Consecutive patients undergoing hepatic resections between 2000 and 2012 for synchronous colorectal liver metastases were identified from a prospectively maintained database. Of the 112 hepatic resections that were performed, 36 were simultaneous resections and 76 were sequential resections. There was no difference in disease severity: number of metastases (P 0.228), metastatic size (P 0.58), the primary tumour nodal status (P 0.283), CEA (P 0.387) or the presence of extra-hepatic metastases (P 1.0). Major hepatic resections were performed in 23 (64%) and 60 (79%) of patients in the simultaneous and sequential groups respectively (P 0.089). Intra-operatively no differences were found in blood loss (P 1.0), duration of surgery (P 0.284) or number of adverse events (P 1.0). There were no differences in post-operative complications (P 0.161) or post-operative mortality (P 0.241). The length of hospital stay was 14 (95% CI 12.0-18.0) and 18.5 (95% CI 16.0-23.0) days in the simultaneous and sequential groups respectively (P 0.03). The 3-year overall survival was 75% and 64% in the simultaneous and sequential groups respectively (P 0.379). The 3-year hepatic recurrence free survival was 61% and 46% in the simultaneous and sequential groups respectively (P 0.254). Simultaneous resections result in similar short-term and long-term outcomes as patients receiving sequential resections with comparable metastatic disease and are associated with a significant reduction in the length of stay. Copyright © 2013 Elsevier Ltd. All rights reserved.
Computerized Classification Testing with the Rasch Model
ERIC Educational Resources Information Center
Eggen, Theo J. H. M.
2011-01-01
If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…
NASA Astrophysics Data System (ADS)
Chen, Xinjia; Lacy, Fred; Carriere, Patrick
2015-05-01
Sequential test algorithms are playing increasingly important roles for quick detecting network intrusions such as portscanners. In view of the fact that such algorithms are usually analyzed based on intuitive approximation or asymptotic analysis, we develop an exact computational method for the performance analysis of such algorithms. Our method can be used to calculate the probability of false alarm and average detection time up to arbitrarily pre-specified accuracy.
Functionalized sorbent for chemical separations and sequential forming process
Fryxell, Glen E [Kennewick, WA; Zemanian, Thomas S [Richland, WA
2012-03-20
A highly functionalized sorbent and sequential process for making are disclosed. The sorbent includes organic short-length amino silanes and organic oligomeric polyfunctional amino silanes that are dispersed within pores of a porous support that form a 3-dimensional structure containing highly functionalized active binding sites for sorption of analytes.
Busse, Sebastian; Schwarting, Rainer K. W.
2016-01-01
The present study is part of a series of experiments, where we analyze why and how damage of the rat’s dorsal hippocampus (dHC) can enhance performance in a sequential reaction time task (SRTT). In this task, sequences of distinct visual stimulus presentations are food-rewarded in a fixed-ratio-13-schedule. Our previous study (Busse and Schwarting, 2016) had shown that rats with lesions of the dHC show substantially shorter session times and post-reinforcement pauses (PRPs) than controls, which allows for more practice when daily training is kept constant. Since sequential behavior is based on instrumental performance, a sequential benefit might be secondary to that. In order to test this hypothesis in the present study, we performed two experiments, where pseudorandom rather than sequential stimulus presentation was used in rats with excitotoxic dorsal hippocampal lesions. Again, we found enhanced performance in the lesion-group in terms of shorter session times and PRPs. During the sessions we found that the lesion-group spent less time with non-instrumental behavior (i.e., grooming, sniffing, and rearing) after prolonged instrumental training. Also, such rats showed moderate evidence for an extinction impairment under devalued food reward conditions and significant deficits in a response-outcome (R-O)-discrimination task in comparison to a control-group. These findings suggest that facilitatory effects on instrumental performance after dorsal hippocampal lesions may be primarily a result of complex behavioral changes, i.e., reductions of behavioral flexibility and/or alterations in motivation, which then result in enhanced instrumental learning. PMID:27375453
Sleep to the beat: A nap favours consolidation of timing.
Verweij, Ilse M; Onuki, Yoshiyuki; Van Someren, Eus J W; Van der Werf, Ysbrand D
2016-06-01
Growing evidence suggests that sleep is important for procedural learning, but few studies have investigated the effect of sleep on the temporal aspects of motor skill learning. We assessed the effect of a 90-min day-time nap on learning a motor timing task, using 2 adaptations of a serial interception sequence learning (SISL) task. Forty-two right-handed participants performed the task before and after a 90-min period of sleep or wake. Electroencephalography (EEG) was recorded throughout. The motor task consisted of a sequential spatial pattern and was performed according to 2 different timing conditions, that is, either following a sequential or a random temporal pattern. The increase in accuracy was compared between groups using a mixed linear regression model. Within the sleep group, performance improvement was modeled based on sleep characteristics, including spindle- and slow-wave density. The sleep group, but not the wake group, showed improvement in the random temporal, but especially and significantly more strongly in the sequential temporal condition. None of the sleep characteristics predicted improvement on either general of the timing conditions. In conclusion, a daytime nap improves performance on a timing task. We show that performance on the task with a sequential timing sequence benefits more from sleep than motor timing. More important, the temporal sequence did not benefit initial learning, because differences arose only after an offline period and specifically when this period contained sleep. Sleep appears to aid in the extraction of regularities for optimal subsequent performance. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Lang, Brian H H; Woo, Yu-Cho; Chiu, Keith Wan-Hang
2018-03-19
Assessing the efficacy and safety of sequential high-intensity focused ultrasound (HIFU) ablation in a multinodular goitre (MNG) by comparing them with single HIFU ablation. One hundred and four (84.6%) patients underwent single ablation of a single nodule (group I), while 19 (15.4%) underwent sequential ablation of two relatively-dominant nodules in a MNG (group II). Extent of shrinkage per nodule [by volume reduction ratio (VRR)], pain scores (by 0-10 visual analogue scale) during and after ablation, and rate of vocal cord palsy (VCP), skin burn and nausea/vomiting were compared between the two groups. All 19 (100%) sequential ablations completed successfully. The 3- and 6-month VRR of each nodule were comparable between the two groups (p > 0.05) and in group II, the 3- and 6-month VRR between the first and second nodules were comparable (p = 0.710 and p = 0.548, respectively). Pain score was significantly higher in group II in the morning after ablation (2.29 vs 1.15, p = 0.047) and nausea/vomiting occurred significantly more frequently in group II (15.8% vs 0.0%, p = 0.012). However, VCP and skin burn were comparable (p > 0.05). Sequential ablation had comparable efficacy and safety as single ablation. However, patients undergoing sequential ablation are at higher likelihood of pain in the following morning and nausea/vomiting after ablation. • Sequential HIFU ablation is well-tolerated in patients with two dominant thyroid nodules • More pain is experienced in the morning following sequential HIFU ablation • More nausea/vomiting is experienced following sequential HIFU ablation.
Panahbehagh, B.; Smith, D.R.; Salehi, M.M.; Hornbach, D.J.; Brown, D.J.; Chan, F.; Marinova, D.; Anderssen, R.S.
2011-01-01
Assessing populations of rare species is challenging because of the large effort required to locate patches of occupied habitat and achieve precise estimates of density and abundance. The presence of a rare species has been shown to be correlated with presence or abundance of more common species. Thus, ecological community richness or abundance can be used to inform sampling of rare species. Adaptive sampling designs have been developed specifically for rare and clustered populations and have been applied to a wide range of rare species. However, adaptive sampling can be logistically challenging, in part, because variation in final sample size introduces uncertainty in survey planning. Two-stage sequential sampling (TSS), a recently developed design, allows for adaptive sampling, but avoids edge units and has an upper bound on final sample size. In this paper we present an extension of two-stage sequential sampling that incorporates an auxiliary variable (TSSAV), such as community attributes, as the condition for adaptive sampling. We develop a set of simulations to approximate sampling of endangered freshwater mussels to evaluate the performance of the TSSAV design. The performance measures that we are interested in are efficiency and probability of sampling a unit occupied by the rare species. Efficiency measures the precision of population estimate from the TSSAV design relative to a standard design, such as simple random sampling (SRS). The simulations indicate that the density and distribution of the auxiliary population is the most important determinant of the performance of the TSSAV design. Of the design factors, such as sample size, the fraction of the primary units sampled was most important. For the best scenarios, the odds of sampling the rare species was approximately 1.5 times higher for TSSAV compared to SRS and efficiency was as high as 2 (i.e., variance from TSSAV was half that of SRS). We have found that design performance, especially for adaptive designs, is often case-specific. Efficiency of adaptive designs is especially sensitive to spatial distribution. We recommend that simulations tailored to the application of interest are highly useful for evaluating designs in preparation for sampling rare and clustered populations.
Integrated analysis of large space systems
NASA Technical Reports Server (NTRS)
Young, J. P.
1980-01-01
Based on the belief that actual flight hardware development of large space systems will necessitate a formalized method of integrating the various engineering discipline analyses, an efficient highly user oriented software system capable of performing interdisciplinary design analyses with tolerable solution turnaround time is planned Specific analysis capability goals were set forth with initial emphasis given to sequential and quasi-static thermal/structural analysis and fully coupled structural/control system analysis. Subsequently, the IAC would be expanded to include a fully coupled thermal/structural/control system, electromagnetic radiation, and optical performance analyses.
The effect of illumination on the formation of metal halide perovskite films
NASA Astrophysics Data System (ADS)
Ummadisingu, Amita; Steier, Ludmilla; Seo, Ji-Youn; Matsui, Taisuke; Abate, Antonio; Tress, Wolfgang; Grätzel, Michael
2017-04-01
Optimizing the morphology of metal halide perovskite films is an important way to improve the performance of solar cells when these materials are used as light harvesters, because film homogeneity is correlated with photovoltaic performance. Many device architectures and processing techniques have been explored with the aim of achieving high-performance devices, including single-step deposition, sequential deposition and anti-solvent methods. Earlier studies have looked at the influence of reaction conditions on film quality, such as the concentration of the reactants and the reaction temperature. However, the precise mechanism of the reaction and the main factors that govern it are poorly understood. The consequent lack of control is the main reason for the large variability observed in perovskite morphology and the related solar-cell performance. Here we show that light has a strong influence on the rate of perovskite formation and on film morphology in both of the main deposition methods currently used: sequential deposition and the anti-solvent method. We study the reaction of a metal halide (lead iodide) with an organic compound (methylammonium iodide) using confocal laser scanning fluorescence microscopy and scanning electron microscopy. The lead iodide crystallizes before the intercalation of methylammonium iodide commences, producing the methylammonium lead iodide perovskite. We find that the formation of perovskite via such a sequential deposition is much accelerated by light. The influence of light on morphology is reflected in a doubling of solar-cell efficiency. Conversely, using the anti-solvent method to form methyl ammonium lead iodide perovskite in a single step from the same starting materials, we find that the best photovoltaic performance is obtained when films are produced in the dark. The discovery of light-activated crystallization not only identifies a previously unknown source of variability in opto-electronic properties, but also opens up new ways of tuning morphology and structuring perovskites for various applications.
Walz, A D; Doppl, K; Kaza, E; Roschka, S; Platz, T; Lotze, M
2015-02-01
We were interested in motor performance gain after unilateral hand motor training and associated changes of cerebral and cerebellar movement representation tested with functional magnetic resonance imaging (fMRI) before and after training. Therefore, we trained the left hand of strongly right-handed healthy participants with a comprehensive training (arm ability training, AAT) over two weeks. Motor performance was tested for the trained and non-trained hand before and after the training period. Functional imaging was performed for the trained and the non-trained hand separately and comprised force modulation with the fist, sequential finger movements and a fast writing task. After the training period the performance gain of tapping movements was comparable for both hand sides, whereas the motor performance for writing showed a higher training effect for the trained hand. fMRI showed a reduction of activation in supplementary motor, dorsolateral prefrontal cortex, parietal cortical areas and lateral cerebellar areas during sequential finger movements over time. During left hand writing lateral cerebellar hemisphere also showed reduced activation, while activation of the anterior cerebellar hemisphere was increased. An initially high anterior cerebellar activation magnitude was a predictive value for high training outcome of finger tapping and visual guided movements. During the force modulation task we found increased activation in the striate. Overall, a comprehensive long-term training of the less skillful hand in healthy participants resulted in relevant motor performance improvements, as well as an intermanual learning transfer differently pronounced for the type of movement tested. Whereas cortical motor area activation decreased over time, cerebellar anterior hemisphere and striatum activity seem to represent increasing resources after long-term motor training. Copyright © 2014 Elsevier B.V. All rights reserved.
Micromachined devices: the impact of controlled geometry from cell-targeting to bioavailability.
Tao, Sarah L; Desai, Tejal A
2005-12-05
Advances in microelectomechanical systems (MEMS) have allowed the microfabrication of polymeric substrates and the development of a novel class of controlled delivery devices. These vehicles have specifically tailored three-dimensional physical and chemical features which, together, provide the capacity to target cells, promote unidirectional controlled release, and enhance permeation across the intestinal epithelial barrier. Examining the biological response at the microdevice biointerface may provide insight into the benefits of customized surface chemistry and structure in terms of complex drug delivery vehicle design. Therefore, the aim of this work was to determine the interfacial effects of selective surface chemistry and architecture of tomato lectin (TL)-modified poly(methyl methacrylate) (PMMA) drug delivery microdevices on the Caco-2 cell line, a model of the gastrointestinal tract.
Cell Membrane Coating Nanotechnology.
Fang, Ronnie H; Kroll, Ashley V; Gao, Weiwei; Zhang, Liangfang
2018-06-01
Nanoparticle-based therapeutic, prevention, and detection modalities have the potential to greatly impact how diseases are diagnosed and managed in the clinic. With the wide range of nanomaterials available, the rational design of nanocarriers on an application-specific basis has become increasingly commonplace. Here, a comprehensive overview is provided on an emerging platform: cell-membrane-coating nanotechnology. As a fundamental unit of biology, cells carry out a wide range of functions, including the remarkable ability to interface and interact with their surrounding environment. Instead of attempting to replicate such functions via synthetic techniques, researchers are now directly leveraging naturally derived cell membranes as a means of bestowing nanoparticles with enhanced biointerfacing capabilities. This top-down technique is facile, highly generalizable, and has the potential to greatly augment existing nanocarriers. Further, the introduction of a natural membrane substrate onto nanoparticles surfaces has enabled additional applications beyond those traditionally associated with nanomedicine. Despite its relative youth, there exists an impressive body of literature on cell membrane coating, which is covered here in detail. Overall, there is still significant room for development, as researchers continue to refine existing workflows while finding new and exciting applications that can take advantage of this developing technology. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Schulz, Daniela N; Kremers, Stef P J; Vandelanotte, Corneel; van Adrichem, Mathieu J G; Schneider, Francine; Candel, Math J J M; de Vries, Hein
2014-01-27
Web-based computer-tailored interventions for multiple health behaviors can have a significant public health impact. Yet, few randomized controlled trials have tested this assumption. The objective of this paper was to test the effects of a sequential and simultaneous Web-based tailored intervention on multiple lifestyle behaviors. A randomized controlled trial was conducted with 3 tailoring conditions (ie, sequential, simultaneous, and control conditions) in the Netherlands in 2009-2012. Follow-up measurements took place after 12 and 24 months. The intervention content was based on the I-Change model. In a health risk appraisal, all respondents (N=5055) received feedback on their lifestyle behaviors that indicated whether they complied with the Dutch guidelines for physical activity, vegetable consumption, fruit consumption, alcohol intake, and smoking. Participants in the sequential (n=1736) and simultaneous (n=1638) conditions received tailored motivational feedback to change unhealthy behaviors one at a time (sequential) or all at the same time (simultaneous). Mixed model analyses were performed as primary analyses; regression analyses were done as sensitivity analyses. An overall risk score was used as outcome measure, then effects on the 5 individual lifestyle behaviors were assessed and a process evaluation was performed regarding exposure to and appreciation of the intervention. Both tailoring strategies were associated with small self-reported behavioral changes. The sequential condition had the most significant effects compared to the control condition after 12 months (T1, effect size=0.28). After 24 months (T2), the simultaneous condition was most effective (effect size=0.18). All 5 individual lifestyle behaviors changed over time, but few effects differed significantly between the conditions. At both follow-ups, the sequential condition had significant changes in smoking abstinence compared to the simultaneous condition (T1 effect size=0.31; T2 effect size=0.41). The sequential condition was more effective in decreasing alcohol consumption than the control condition at 24 months (effect size=0.27). Change was predicted by the amount of exposure to the intervention (total visiting time: beta=-.06; P=.01; total number of visits: beta=-.11; P<.001). Both interventions were appreciated well by respondents without significant differences between conditions. Although evidence was found for the effectiveness of both programs, no simple conclusive finding could be drawn about which intervention mode was more effective. The best kind of intervention may depend on the behavior that is targeted or on personal preferences and motivation. Further research is needed to identify moderators of intervention effectiveness. The results need to be interpreted in view of the high and selective dropout rates, multiple comparisons, and modest effect sizes. However, a large number of people were reached at low cost and behavioral change was achieved after 2 years. Nederlands Trial Register: NTR 2168; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2168 (Archived by WebCite at http://www.webcitation.org/6MbUqttYB).
Induction of simultaneous and sequential malolactic fermentation in durian wine.
Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan
2016-08-02
This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.
Solid State Television Camera (CID)
NASA Technical Reports Server (NTRS)
Steele, D. W.; Green, W. T.
1976-01-01
The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.
Spatial-Sequential and Spatial-Simultaneous Working Memory in Individuals with Williams Syndrome
ERIC Educational Resources Information Center
Lanfranchi, Silvia; De Mori, Letizia; Mammarella, Irene C.; Carretti, Barbara; Vianello, Renzo
2015-01-01
The aim of the present study was to compare visuospatial working memory performance in 18 individuals with Williams syndrome (WS) and 18 typically developing (TD) children matched for nonverbal mental age. Two aspects were considered: task presentation format (i.e., spatial-sequential or spatial-simultaneous), and level of attentional control…
Orthographic Processing and Visual Sequential Memory in Unexpectedly Poor Spellers
ERIC Educational Resources Information Center
Holmes, Virginia M.; Malone, Aisling M.; Redenbach, Holly
2008-01-01
Does unexpectedly poor spelling in adults result from inferior visual sequential memory? In one experiment, unexpectedly poor spellers performed significantly worse than better spellers in the immediate reproduction of sequences of visual symbols, but in a second experiment, the effect was not replicated. Poor spellers were also no worse at the…
NASA Astrophysics Data System (ADS)
Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John
2016-09-01
DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.
Description and effects of sequential behavior practice in teacher education.
Sharpe, T; Lounsbery, M; Bahls, V
1997-09-01
This study examined the effects of a sequential behavior feedback protocol on the practice-teaching experiences of undergraduate teacher trainees. The performance competencies of teacher trainees were analyzed using an alternative opportunities for appropriate action measure. Data support the added utility of sequential (Sharpe, 1997a, 1997b) behavior analysis information in systematic observation approaches to teacher education. One field-based undergraduate practicum using sequential behavior (i.e., field systems analysis) principles was monitored. Summarized are the key elements of the (a) classroom instruction provided as a precursor to the practice teaching experience, (b) practice teaching experience, and (c) field systems observation tool used for evaluation and feedback, including multiple-baseline data (N = 4) to support this approach to teacher education. Results point to (a) the strong relationship between sequential behavior feedback and the positive change in four preservice teachers' day-to-day teaching practices in challenging situational contexts, and (b) the relationship between changes in teacher practices and positive changes in the behavioral practices of gymnasium pupils. Sequential behavior feedback was also socially validated by the undergraduate participants and Professional Development School teacher supervisors in the study.
Considering User's Access Pattern in Multimedia File Systems
NASA Astrophysics Data System (ADS)
Cho, KyoungWoon; Ryu, YeonSeung; Won, Youjip; Koh, Kern
2002-12-01
Legacy buffer cache management schemes for multimedia server are grounded at the assumption that the application sequentially accesses the multimedia file. However, user access pattern may not be sequential in some circumstances, for example, in distance learning application, where the user may exploit the VCR-like function(rewind and play) of the system and accesses the particular segments of video repeatedly in the middle of sequential playback. Such a looping reference can cause a significant performance degradation of interval-based caching algorithms. And thus an appropriate buffer cache management scheme is required in order to deliver desirable performance even under the workload that exhibits looping reference behavior. We propose Adaptive Buffer cache Management(ABM) scheme which intelligently adapts to the file access characteristics. For each opened file, ABM applies either the LRU replacement or the interval-based caching depending on the Looping Reference Indicator, which indicates that how strong temporally localized access pattern is. According to our experiment, ABM exhibits better buffer cache miss ratio than interval-based caching or LRU, especially when the workload exhibits not only sequential but also looping reference property.
Pooler, B Dustin; Hernando, Diego; Ruby, Jeannine A; Ishii, Hiroshi; Shimakawa, Ann; Reeder, Scott B
2018-04-17
Current chemical-shift-encoded (CSE) MRI techniques for measuring hepatic proton density fat fraction (PDFF) are sensitive to motion artifacts. Initial validation of a motion-robust 2D-sequential CSE-MRI technique for quantification of hepatic PDFF. Phantom study and prospective in vivo cohort. Fifty adult patients (27 women, 23 men, mean age 57.2 years). 3D, 2D-interleaved, and 2D-sequential CSE-MRI acquisitions at 1.5T. Three CSE-MRI techniques (3D, 2D-interleaved, 2D-sequential) were performed in a PDFF phantom and in vivo. Reference standards were 3D CSE-MRI PDFF measurements for the phantom study and single-voxel MR spectroscopy hepatic PDFF measurements (MRS-PDFF) in vivo. In vivo hepatic MRI-PDFF measurements were performed during a single breath-hold (BH) and free breathing (FB), and were repeated by a second reader for the FB 2D-sequential sequence to assess interreader variability. Correlation plots to validate the 2D-sequential CSE-MRI against the phantom and in vivo reference standards. Bland-Altman analysis of FB versus BH CSE-MRI acquisitions to evaluate robustness to motion. Bland-Altman analysis to assess interreader variability. Phantom 2D-sequential CSE-MRI PDFF measurements demonstrated excellent agreement and correlation (R 2 > 0.99) with 3D CSE-MRI. In vivo, the mean (±SD) hepatic PDFF was 8.8 ± 8.7% (range 0.6-28.5%). Compared with BH acquisitions, FB hepatic PDFF measurements demonstrated bias of +0.15% for 2D-sequential compared with + 0.53% for 3D and +0.94% for 2D-interleaved. 95% limits of agreement (LOA) were narrower for 2D-sequential (±0.99%), compared with 3D (±3.72%) and 2D-interleaved (±3.10%). All CSE-MRI techniques had excellent correlation with MRS (R 2 > 0.97). The FB 2D-sequential acquisition demonstrated little interreader variability, with mean bias of +0.07% and 95% LOA of ± 1.53%. This motion-robust 2D-sequential CSE-MRI can accurately measure hepatic PDFF during free breathing in a patient population with a range of PDFF values of 0.6-28.5%, permitting accurate quantification of liver fat content without the need for suspended respiration. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
One-step surface modification of poly(dimethylsiloxane) by undecylenic acid
NASA Astrophysics Data System (ADS)
Zhou, Jinwen; McInnes, Steven J. P.; Md Jani, Abdul Mutalib; Ellis, Amanda V.; Voelcker, Nicolas H.
2008-12-01
Poly(dimethylsiloxane) (PDMS) is a popular material for microfluidic devices due to its relatively low cost, ease of fabrication, oxygen permeability and optical transmission characteristics. However, its highly hydrophobic surface is still the main factor limiting its wide application, in particular as a material for biointerfaces. A simple and rapid method to form a relatively stable hydrophilised PDMS surface is reported in this paper. The PDMS surface was treated with pure undecylenic acid (UDA) for 10 min, 1 h and 1 day at 80 °C in a sealed container. The effects of the surface modification were investigated using water contact angle (WCA) measurements, Fourier transform infrared spectroscopy in attenuated total reflection mode (FTIR-ATR), and streaming zeta-potential analysis. The water contact angle of 1 day UDAmodified PDMS was found to decrease from that of native PDMS (110 °) to 75 °, demonstrating an increase in wettability of the surface. A distinctive peak at 1715 cm-1 in the FTIR-ATR spectra after UDA treatment was representative of carboxylation of the PDMS surface. The measured zeta-potential (ζ) at pH 4 changed from -27 mV for pure PDMS to -19 mV after UDA treatment. In order to confirm carboxylation of the surface visually, Lucifer Yellow CH fluorescence dye was reacted via a condensation reaction to the 1 day UDA modified PDMS surface. Fluorescent microscopy showed Lucifer Yellow CH fluorescence on the carboxylated surface, but not on the pure PDMS surface. Stability experiments were also performed showing that 1 day modified UDA samples were stable in both MilliQ water at 50 °C for 17 h, and in a desiccator at room temperature for 19.5 h.
Présent, Romain M; Rotureau, Elise; Billard, Patrick; Pagnout, Christophe; Sohm, Bénédicte; Flayac, Justine; Gley, Renaud; Pinheiro, José P; Duval, Jérôme F L
2017-11-08
Genetically engineered microorganisms are alternatives to physicochemical methods for remediation of metal-contaminated aquifers due to their remarkable bioaccumulation capacities. The design of such biosystems would benefit from the elaboration of a sound quantitative connection between performance in terms of metal removal from aqueous solution and dynamics of the multiscale processes leading to metal biouptake. In this work, this elaboration is reported for Escherichia coli cells modified to overexpress intracellular metallothionein (MTc), a strong proteinaceous metal chelator. Depletion kinetics of Cd(ii) from bulk solution following biouptake and intracellular accumulation is addressed as a function of cell volume fraction using electroanalytical probes and ligand exchange-based analyses. It is shown that metal biouptake in the absence and presence of MTc is successfully interpreted on the basis of a formalism recently developed for metal partitioning dynamics at biointerfaces with integration of intracellular metal speciation. The analysis demonstrates how fast sequestration of metals by intracellular MTc bypasses metal excretion (efflux) and enhances the rate of metal depletion to an extent such that complete removal is achieved at sufficiently large cell volume fractions. The magnitude of the stability constant of nanoparticulate metal-MTc complexes, as derived from refined analysis of macroscopic bulk metal depletion data, is further confirmed by independent electrochemical measurement of metal binding by purified MTc extracts.
Hafid, Halimatun Saadiah; Nor 'Aini, Abdul Rahman; Mokhtar, Mohd Noriznan; Talib, Ahmad Tarmezee; Baharuddin, Azhari Samsu; Umi Kalsom, Md Shah
2017-09-01
In Malaysia, the amount of food waste produced is estimated at approximately 70% of total municipal solid waste generated and characterised by high amount of carbohydrate polymers such as starch, cellulose, and sugars. Considering the beneficial organic fraction contained, its utilization as an alternative substrate specifically for bioethanol production has receiving more attention. However, the sustainable production of bioethanol from food waste is linked to the efficient pretreatment needed for higher production of fermentable sugar prior to fermentation. In this work, a modified sequential acid-enzymatic hydrolysis process has been developed to produce high concentration of fermentable sugars; glucose, sucrose, fructose and maltose. The process started with hydrothermal and dilute acid pretreatment by hydrochloric acid (HCl) and sulphuric acid (H 2 SO 4 ) which aim to degrade larger molecules of polysaccharide before accessible for further steps of enzymatic hydrolysis by glucoamylase. A kinetic model is proposed to perform an optimal hydrolysis for obtaining high fermentable sugars. The results suggested that a significant increase in fermentable sugar production (2.04-folds) with conversion efficiency of 86.8% was observed via sequential acid-enzymatic pretreatment as compared to dilute acid pretreatment (∼42.4% conversion efficiency). The bioethanol production by Saccharomyces cerevisiae utilizing fermentable sugar obtained shows ethanol yield of 0.42g/g with conversion efficiency of 85.38% based on the theoretical yield was achieved. The finding indicates that food waste can be considered as a promising substrate for bioethanol production. Copyright © 2017. Published by Elsevier Ltd.
Chua, YaoHui K; Quek, Raymond K K; Kong, Pui W
2017-03-01
This study aimed (1) to profile the plantar loading characteristics when performing the basketball lay-up in a realistic setting and (2) to determine the number of trials necessary to establish a stable mean for plantar loading variables during the lay-up. Thirteen university male basketball players [age: 23.0 (1.4) years, height: 1.75 (0.05) m, mass: 68.4 (8.6) kg] performed ten successful basketball lay-ups from a stationary position. Plantar loading variables were recorded using the Novel Pedar-X in-shoe system. Loading variables including peak force, peak pressure, and pressure-time integral were extracted from eight foot regions. Performance stability of plantar loading variables during the take-off and landing steps were assessed using the sequential averaging technique and intra-class correlation coefficient (ICC). High plantar loadings were experienced at the heel during the take-off steps, and both the heel and forefoot regions upon landing. The sequential estimation technique revealed a five-eight trial range to achieve a stable mean across all plantar loading variables, whereas ICC analysis was insensitive to inter-trial differences of repeated lay-up performances. Future studies and performance evaluation protocols on plantar loading during basketball lay-ups should include at least eight trials to ensure that the measurements obtained are sufficiently stable.
A Hybrid Shared-Memory Parallel Max-Tree Algorithm for Extreme Dynamic-Range Images.
Moschini, Ugo; Meijster, Arnold; Wilkinson, Michael H F
2018-03-01
Max-trees, or component trees, are graph structures that represent the connected components of an image in a hierarchical way. Nowadays, many application fields rely on images with high-dynamic range or floating point values. Efficient sequential algorithms exist to build trees and compute attributes for images of any bit depth. However, we show that the current parallel algorithms perform poorly already with integers at bit depths higher than 16 bits per pixel. We propose a parallel method combining the two worlds of flooding and merging max-tree algorithms. First, a pilot max-tree of a quantized version of the image is built in parallel using a flooding method. Later, this structure is used in a parallel leaf-to-root approach to compute efficiently the final max-tree and to drive the merging of the sub-trees computed by the threads. We present an analysis of the performance both on simulated and actual 2D images and 3D volumes. Execution times are about better than the fastest sequential algorithm and speed-up goes up to on 64 threads.
NASA Astrophysics Data System (ADS)
Masuda, Hiroshi; Kanda, Yutaro; Okamoto, Yoshifumi; Hirono, Kazuki; Hoshino, Reona; Wakao, Shinji; Tsuburaya, Tomonori
2017-12-01
It is very important to design electrical machineries with high efficiency from the point of view of saving energy. Therefore, topology optimization (TO) is occasionally used as a design method for improving the performance of electrical machinery under the reasonable constraints. Because TO can achieve a design with much higher degree of freedom in terms of structure, there is a possibility for deriving the novel structure which would be quite different from the conventional structure. In this paper, topology optimization using sequential linear programming using move limit based on adaptive relaxation is applied to two models. The magnetic shielding, in which there are many local minima, is firstly employed as firstly benchmarking for the performance evaluation among several mathematical programming methods. Secondly, induction heating model is defined in 2-D axisymmetric field. In this model, the magnetic energy stored in the magnetic body is maximized under the constraint on the volume of magnetic body. Furthermore, the influence of the location of the design domain on the solutions is investigated.
Hsieh, Tsung-Yu; Huang, Chi-Kai; Su, Tzu-Sen; Hong, Cheng-You; Wei, Tzu-Chien
2017-03-15
Crystal morphology and structure are important for improving the organic-inorganic lead halide perovskite semiconductor property in optoelectronic, electronic, and photovoltaic devices. In particular, crystal growth and dissolution are two major phenomena in determining the morphology of methylammonium lead iodide perovskite in the sequential deposition method for fabricating a perovskite solar cell. In this report, the effect of immersion time in the second step, i.e., methlyammonium iodide immersion in the morphological, structural, optical, and photovoltaic evolution, is extensively investigated. Supported by experimental evidence, a five-staged, time-dependent evolution of the morphology of methylammonium lead iodide perovskite crystals is established and is well connected to the photovoltaic performance. This result is beneficial for engineering optimal time for methylammonium iodide immersion and converging the solar cell performance in the sequential deposition route. Meanwhile, our result suggests that large, well-faceted methylammonium lead iodide perovskite single crystal may be incubated by solution process. This offers a low cost route for synthesizing perovskite single crystal.
Zabihi, Fatemeh; Ahmadian-Yazdi, Mohammad-Reza; Eslamian, Morteza
2016-12-01
In this paper, a scalable and fast process is developed and employed for the fabrication of the perovskite light harvesting layer in inverted planar heterojunction solar cell (FTO/PEDOT:PSS/CH3NH3PbI3-x Cl x /PCBM/Al). Perovskite precursor solutions are sprayed onto an ultrasonically vibrating substrate in two sequential steps via a process herein termed as the two-step sequential substrate vibration-assisted spray coating (2S-SVASC). The gentle imposed ultrasonic vibration on the substrate promotes droplet spreading and coalescence, surface wetting, evaporation, mixing of reagents, and uniform growth of perovskite nanocrystals. The role of the substrate temperature, substrate vibration intensity, and the time interval between the two sequential sprays are studied on the roughness, coverage, and crystalline structure of perovskite thin films. We demonstrate that a combination of a long time interval between spraying of precursor solutions (15 min), a high substrate temperature (120 °C), and a mild substrate vibration power (5 W) results in a favorable morphology and surface quality. The characteristics and performance of prepared perovskite thin films made via the 2S-SVASC technique are compared with those of the co-sprayed perovskite thin films. The maximum power conversion efficiency of 5.08 % on a 0.3-cm(2) active area is obtained for the device made via the scalable 2S-SVASC technique.
Two-way sequential time synchronization: Preliminary results from the SIRIO-1 experiment
NASA Technical Reports Server (NTRS)
Detoma, E.; Leschiutta, S.
1981-01-01
A two-way time synchronization experiment performed in the spring of 1979 and 1980 via the Italian SIRIO-1 experimental telecommunications satellite is described. The experiment was designed and implemented to precisely monitor the satellite motion and to evaluate the possibility of performing a high precision, two-way time synchronization using a single communication channel, time-shared between the participating sites. Results show that the precision of the time synchronization is between 1 and 5 ns, while the evaluation and correction of the satellite motion effect was performed with an accuracy of a few nanoseconds or better over a time interval from 1 up to 20 seconds.
Nutritional therapy in cirrhosis or alcoholic hepatitis: a systematic review and meta-analysis.
Fialla, Annette D; Israelsen, Mads; Hamberg, Ole; Krag, Aleksander; Gluud, Lise Lotte
2015-09-01
Patients with cirrhosis and alcoholic hepatitis are often malnourished and have a superimposed stress metabolism, which increases nutritional demands. We performed a systematic review on the effects of nutritional therapy vs. no intervention for patients with cirrhosis or alcoholic hepatitis. We included trials on nutritional therapy designed to fulfil at least 75% of daily nutritional demand. Authors extracted data in an independent manner. Random-effects and fixed-effect meta-analyses were performed and the results expressed as risk ratios (RR) with 95% confidence intervals (CI). Sequential analyses were performed to evaluate the risk of spurious findings because of random and systematic errors. Subgroup and sensitivity analyses were performed to evaluate the risk of bias and sources of between trial heterogeneity. Thirteen randomized controlled trials with 329 allocated to enteral (nine trials) or intravenous (four trials) nutrition and 334 controls. All trials were classed as having a high risk of bias. Random-effects meta-analysis showed that nutritional therapy reduced mortality 0.80 (95% CI, 0.64 to 0.99). The result was not confirmed in sequential analysis. Fixed-effect analysis suggested that nutrition prevented overt hepatic encephalopathy (0.73; 95% CI, 0.55 to 0.96) and infection (0.66; 95% CI, 0.45 to 0.98, respectively), but the results were not confirmed in random-effects analyses. Our review suggests that nutritional therapy may have beneficial effects on clinical outcomes in cirrhosis and alcoholic hepatitis. High-quality trials are needed to verify our findings. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Zaki, Farzana; Hou, Isabella; Huang, Qiongdan; Cooper, Denver; Patel, Divya; Liu, Xuan; Yang, Yi
2017-02-01
Optical coherence tomography (OCT) has great potential for the examination of oil paintings, particularly for celebrated masterpieces by great artists in history. We developed an OCT system for large field of view (FOV), high definition (HD) imaging of oil paintings. To achieve large FOV, we translated the sample using a pair of high-precision linear motors and performed sequential volumetric imaging on adjacent, non-overlapping regions. Through 3D OCT imaging, the surface terrain and subsurface microarchitecture of the paintings have been characterized and visualized.
Resin/graphite fiber composites
NASA Technical Reports Server (NTRS)
Cavano, P. J.; Jones, R. J.; Vaughan, R. W.
1972-01-01
High temperature resin matrices suitable for use in advanced graphite fiber composites for jet engine applications were evaluated. A series of planned, sequential screening experiments with resin systems in composite form were performed to reduce the number of candidates to a single A-type polyimide resin that repetitively produced void-free, high strength and modulus composites acceptable for use in the 550 F range for 1000 hours. An optimized processing procedure was established for this system. Extensive mechanical property studies characterized this single system, at room temperature, 500 F, 550 F and 600 F, for various exposure times.
Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.
Lin, Jane-Ming; Tsai, Yi-Yu
2005-01-01
To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P < .01). The mean distance between the first and second eyes was 0.31 +/- 0.25 mm in the sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 < or = 48.3 degrees in the sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.
NASA Astrophysics Data System (ADS)
Feuerstein, Sophie; Plevin, Michael J.; Willbold, Dieter; Brutscher, Bernhard
2012-01-01
An experiment, iHADAMAC, is presented that yields information on the amino-acid type of individual residues in a protein by editing the 1H- 15N correlations into seven different 2D spectra, each corresponding to a different class of amino-acid types. Amino-acid type discrimination is realized via a Hadamard encoding scheme based on four different spin manipulations as recently introduced in the context of the sequential HADAMAC experiment. Both sequential and intra-residue HADAMAC experiments yield highly complementary information that greatly facilitate resonance assignment of proteins with high frequency degeneracy, as demonstrated here for a 188-residue intrinsically disordered protein fragment of the hepatitis C virus protein NS5A.
Hinault, Thomas; Lemaire, Patrick; Phillips, Natalie
2016-01-01
This study investigated age-related differences in electrophysiological signatures of sequential modulations of poorer strategy effects. Sequential modulations of poorer strategy effects refer to decreased poorer strategy effects (i.e., poorer performance when the cued strategy is not the best) on current problem following poorer strategy problems compared to after better strategy problems. Analyses on electrophysiological (EEG) data revealed important age-related changes in time, frequency, and coherence of brain activities underlying sequential modulations of poorer strategy effects. More specifically, sequential modulations of poorer strategy effects were associated with earlier and later time windows (i.e., between 200- and 550 ms and between 850- and 1250 ms). Event-related potentials (ERPs) also revealed an earlier onset in older adults, together with more anterior and less lateralized activations. Furthermore, sequential modulations of poorer strategy effects were associated with theta and alpha frequencies in young adults while these modulations were found in delta frequency and theta inter-hemispheric coherence in older adults, consistent with qualitatively distinct patterns of brain activity. These findings have important implications to further our understanding of age-related differences and similarities in sequential modulations of cognitive control processes during arithmetic strategy execution. Copyright © 2015 Elsevier B.V. All rights reserved.
ChIP-re-ChIP: Co-occupancy Analysis by Sequential Chromatin Immunoprecipitation.
Beischlag, Timothy V; Prefontaine, Gratien G; Hankinson, Oliver
2018-01-01
Chromatin immunoprecipitation (ChIP) exploits the specific interactions between DNA and DNA-associated proteins. It can be used to examine a wide range of experimental parameters. A number of proteins bound at the same genomic location can identify a multi-protein chromatin complex where several proteins work together to regulate gene transcription or chromatin configuration. In many instances, this can be achieved using sequential ChIP; or simply, ChIP-re-ChIP. Whether it is for the examination of specific transcriptional or epigenetic regulators, or for the identification of cistromes, the ability to perform a sequential ChIP adds a higher level of power and definition to these analyses. In this chapter, we describe a simple and reliable method for the sequential ChIP assay.
Adaptive time-sequential binary sensing for high dynamic range imaging
NASA Astrophysics Data System (ADS)
Hu, Chenhui; Lu, Yue M.
2012-06-01
We present a novel image sensor for high dynamic range imaging. The sensor performs an adaptive one-bit quantization at each pixel, with the pixel output switched from 0 to 1 only if the number of photons reaching that pixel is greater than or equal to a quantization threshold. With an oracle knowledge of the incident light intensity, one can pick an optimal threshold (for that light intensity) and the corresponding Fisher information contained in the output sequence follows closely that of an ideal unquantized sensor over a wide range of intensity values. This observation suggests the potential gains one may achieve by adaptively updating the quantization thresholds. As the main contribution of this work, we propose a time-sequential threshold-updating rule that asymptotically approaches the performance of the oracle scheme. With every threshold mapped to a number of ordered states, the dynamics of the proposed scheme can be modeled as a parametric Markov chain. We show that the frequencies of different thresholds converge to a steady-state distribution that is concentrated around the optimal choice. Moreover, numerical experiments show that the theoretical performance measures (Fisher information and Craḿer-Rao bounds) can be achieved by a maximum likelihood estimator, which is guaranteed to find globally optimal solution due to the concavity of the log-likelihood functions. Compared with conventional image sensors and the strategy that utilizes a constant single-photon threshold considered in previous work, the proposed scheme attains orders of magnitude improvement in terms of sensor dynamic ranges.
ERIC Educational Resources Information Center
Kuchinke, Lars; van der Meer, Elke; Krueger, Frank
2009-01-01
Conceptual knowledge of our world is represented in semantic memory in terms of concepts and semantic relations between concepts. We used functional magnetic resonance imaging (fMRI) to examine the cortical regions underlying the processing of sequential and taxonomic relations. Participants were presented verbal cues and performed three tasks:…
ERIC Educational Resources Information Center
Horry, Ruth; Palmer, Matthew A.; Brewer, Neil
2012-01-01
Although the sequential lineup has been proposed as a means of protecting innocent suspects from mistaken identification, little is known about the importance of various aspects of the procedure. One potentially important detail is that witnesses should not know how many people are in the lineup. This is sometimes achieved by…
Examining Age-Related Movement Representations for Sequential (Fine-Motor) Finger Movements
ERIC Educational Resources Information Center
Gabbard, Carl; Cacola, Priscila; Bobbio, Tatiana
2011-01-01
Theory suggests that imagined and executed movement planning relies on internal models for action. Using a chronometry paradigm to compare the movement duration of imagined and executed movements, we tested children aged 7-11 years and adults on their ability to perform sequential finger movements. Underscoring this tactic was our desire to gain a…
ERIC Educational Resources Information Center
Christiansen, Morten H.; Conway, Christopher M.; Onnis, Luca
2012-01-01
We used event-related potentials (ERPs) to investigate the time course and distribution of brain activity while adults performed (1) a sequential learning task involving complex structured sequences and (2) a language processing task. The same positive ERP deflection, the P600 effect, typically linked to difficult or ungrammatical syntactic…
NASA Astrophysics Data System (ADS)
Hughes, Zak E.; Tomásio, Susana M.; Walsh, Tiffany R.
2014-04-01
To fully harness the enormous potential offered by interfaces between graphitic nanostructures and biomolecules, detailed connections between adsorbed conformations and adsorption behaviour are needed. To elucidate these links, a key approach, in partnership with experimental techniques, is molecular simulation. For this, a force-field (FF) that can appropriately capture the relevant physics and chemistry of these complex bio-interfaces, while allowing extensive conformational sampling, and also supporting inter-operability with known biological FFs, is a pivotal requirement. Here, we present and apply such a force-field, GRAPPA, designed to work with the CHARMM FF. GRAPPA is an efficiently implemented polarisable force-field, informed by extensive plane-wave DFT calculations using the revPBE-vdW-DF functional. GRAPPA adequately recovers the spatial and orientational structuring of the aqueous interface of graphene and carbon nanotubes, compared with more sophisticated approaches. We apply GRAPPA to determine the free energy of adsorption for a range of amino acids, identifying Trp, Tyr and Arg to have the strongest binding affinity and Asp to be a weak binder. The GRAPPA FF can be readily incorporated into mainstream simulation packages, and will enable large-scale polarisable biointerfacial simulations at graphitic interfaces, that will aid the development of biomolecule-mediated, solution-based graphene processing and self-assembly strategies.To fully harness the enormous potential offered by interfaces between graphitic nanostructures and biomolecules, detailed connections between adsorbed conformations and adsorption behaviour are needed. To elucidate these links, a key approach, in partnership with experimental techniques, is molecular simulation. For this, a force-field (FF) that can appropriately capture the relevant physics and chemistry of these complex bio-interfaces, while allowing extensive conformational sampling, and also supporting inter-operability with known biological FFs, is a pivotal requirement. Here, we present and apply such a force-field, GRAPPA, designed to work with the CHARMM FF. GRAPPA is an efficiently implemented polarisable force-field, informed by extensive plane-wave DFT calculations using the revPBE-vdW-DF functional. GRAPPA adequately recovers the spatial and orientational structuring of the aqueous interface of graphene and carbon nanotubes, compared with more sophisticated approaches. We apply GRAPPA to determine the free energy of adsorption for a range of amino acids, identifying Trp, Tyr and Arg to have the strongest binding affinity and Asp to be a weak binder. The GRAPPA FF can be readily incorporated into mainstream simulation packages, and will enable large-scale polarisable biointerfacial simulations at graphitic interfaces, that will aid the development of biomolecule-mediated, solution-based graphene processing and self-assembly strategies. Electronic supplementary information (ESI) available: Details of the testing of four different DFT functionals; the adsorption energies and separation distances for the full set of analogue molecules; details of the adsorption energies of the phenyl species on the graphene surface at different adsorption sites; snapshots of the set-ups of the three different water-graphene simulations; plane-wave DFT minimum energy configurations of the full set of analogue molecules; details of the development and parametrisation of the GRAPPA FF; details of the parameters and setup used for the AMEOBAPRO simulations; the probability distribution of the O-H bond vectors of water molecules at the graphene interface; details of the simulation times for the (14 × 0) CNT systems using the different FFs; details of tests performed to determine the contribution of polarisability to binding energies; the RMSD between the reference values and plane-wave DFT values of different groups of molecules; 2D density maps of water on the graphene interface; density and hydrogen bond profiles for the simulations of water inside CNTs; 2D density maps of water inside the CNTs; plots of the collective variable against time for the meta-dynamics simulations; probability distributions of the angle between the plane of the aromatic rings and the graphene surface; the probability distribution of distance of the methyl carbon from the graphene surface for Ala. See DOI: 10.1039/c4nr00468j
Jung, Yoon Suk; Park, Chan Hyuk; Park, Jung Ho; Nam, Eunwoo; Lee, Hang Lak
2017-08-01
The efficacy of Helicobacter pylori eradication regimens may depend on the country where the studies were performed because of the difference in antibiotic resistance. We aimed to analyze the efficacy of H. pylori eradication regimens in Korea where clarithromycin resistance rate is high. We searched for all relevant randomized controlled trials published until November 2016 that investigated the efficacy of H. pylori eradication therapies in Korea. A network meta-analysis was performed to calculate the direct and indirect estimates of efficacy among the eradication regimens. Forty-three studies were identified through a systematic review, of which 34 studies, published since 2005, were included in the meta-analysis. Among 21 included regimens, quinolone-containing sequential therapy for 14 days (ST-Q-14) showed the highest eradication rate (91.4% [95% confidence interval [CI], 86.9%-94.4%] in the intention-to-treat [ITT] analysis). The eradication rate of the conventional triple therapy for 7 days, standard sequential therapy for 10 days, hybrid therapy for 10-14 days, and concomitant therapy for 10-14 days was 71.1% (95% CI, 68.3%-73.7%), 76.2% (95% CI, 72.8%-79.3%), 79.4% (95% CI, 75.5%-82.8%), and 78.3% (95% CI, 75.3%-80.9%), respectively, in the ITT analysis. In the network meta-analysis, ST-Q-14 showed a better comparative efficacy than the conventional triple therapy, standard sequential therapy, hybrid therapy, and concomitant therapy. In addition, tolerability of ST-Q-14 was comparable to those regimens. In Korea, ST-Q-14 showed the highest efficacy in terms of eradication and a comparable tolerability, compared to the results reported for the conventional triple therapy, standard sequential therapy, hybrid therapy, and concomitant therapy. © 2017 John Wiley & Sons Ltd.
Iterative non-sequential protein structural alignment.
Salem, Saeed; Zaki, Mohammed J; Bystroff, Christopher
2009-06-01
Structural similarity between proteins gives us insights into their evolutionary relationships when there is low sequence similarity. In this paper, we present a novel approach called SNAP for non-sequential pair-wise structural alignment. Starting from an initial alignment, our approach iterates over a two-step process consisting of a superposition step and an alignment step, until convergence. We propose a novel greedy algorithm to construct both sequential and non-sequential alignments. The quality of SNAP alignments were assessed by comparing against the manually curated reference alignments in the challenging SISY and RIPC datasets. Moreover, when applied to a dataset of 4410 protein pairs selected from the CATH database, SNAP produced longer alignments with lower rmsd than several state-of-the-art alignment methods. Classification of folds using SNAP alignments was both highly sensitive and highly selective. The SNAP software along with the datasets are available online at http://www.cs.rpi.edu/~zaki/software/SNAP.
Protein classification using sequential pattern mining.
Exarchos, Themis P; Papaloukas, Costas; Lampros, Christos; Fotiadis, Dimitrios I
2006-01-01
Protein classification in terms of fold recognition can be employed to determine the structural and functional properties of a newly discovered protein. In this work sequential pattern mining (SPM) is utilized for sequence-based fold recognition. One of the most efficient SPM algorithms, cSPADE, is employed for protein primary structure analysis. Then a classifier uses the extracted sequential patterns for classifying proteins of unknown structure in the appropriate fold category. The proposed methodology exhibited an overall accuracy of 36% in a multi-class problem of 17 candidate categories. The classification performance reaches up to 65% when the three most probable protein folds are considered.
Patterns and Practices for Future Architectures
2014-08-01
14. SUBJECT TERMS computing architecture, graph algorithms, high-performance computing, big data , GPU 15. NUMBER OF PAGES 44 16. PRICE CODE 17...at Vertex 1 6 Figure 4: Data Structures Created by Kernel 1 of Single CPU, List Implementation Using the Graph in the Example from Section 1.2 9...Figure 5: Kernel 2 of Graph500 BFS Reference Implementation: Single CPU, List 10 Figure 6: Data Structures for Sequential CSR Algorithm 12 Figure 7
Ahmad, Jumana; Swan, Garrett; Bowman, Howard; Wyble, Brad; Nobre, Anna C; Shapiro, Kimron L; McNab, Fiona
2017-07-06
Competition between simultaneously presented visual stimuli lengthens reaction time and reduces both the BOLD response and neural firing. In contrast, conditions of sequential presentation have been assumed to be free from competition. Here we manipulated the spatial proximity of stimuli (Near versus Far conditions) to examine the effects of simultaneous and sequential competition on different measures of working memory (WM) for colour. With simultaneous presentation, the measure of WM precision was significantly lower for Near items, and participants reported the colour of the wrong item more often. These effects were preserved when the second stimulus immediately followed the first, disappeared when they were separated by 500 ms, and were partly recovered (evident for our measure of mis-binding but not WM precision) when the task was altered to encourage participants to maintain the sequentially presented items together in WM. Our results show, for the first time, that competition affects the measure of WM precision, and challenge the assumption that sequential presentation removes competition.
Sequential visibility-graph motifs
NASA Astrophysics Data System (ADS)
Iacovacci, Jacopo; Lacasa, Lucas
2016-04-01
Visibility algorithms transform time series into graphs and encode dynamical information in their topology, paving the way for graph-theoretical time series analysis as well as building a bridge between nonlinear dynamics and network science. In this work we introduce and study the concept of sequential visibility-graph motifs, smaller substructures of n consecutive nodes that appear with characteristic frequencies. We develop a theory to compute in an exact way the motif profiles associated with general classes of deterministic and stochastic dynamics. We find that this simple property is indeed a highly informative and computationally efficient feature capable of distinguishing among different dynamics and robust against noise contamination. We finally confirm that it can be used in practice to perform unsupervised learning, by extracting motif profiles from experimental heart-rate series and being able, accordingly, to disentangle meditative from other relaxation states. Applications of this general theory include the automatic classification and description of physical, biological, and financial time series.
Fast encryption of RGB color digital images using a tweakable cellular automaton based schema
NASA Astrophysics Data System (ADS)
Faraoun, Kamel Mohamed
2014-12-01
We propose a new tweakable construction of block-enciphers using second-order reversible cellular automata, and we apply it to encipher RGB-colored images. The proposed construction permits a parallel encryption of the image content by extending the standard definition of a block cipher to take into account a supplementary parameter used as a tweak (nonce) to control the behavior of the cipher from one region of the image to the other, and hence avoid the necessity to use slow sequential encryption's operating modes. The proposed construction defines a flexible pseudorandom permutation that can be used with efficacy to solve the electronic code book problem without the need to a specific sequential mode. Obtained results from various experiments show that the proposed schema achieves high security and execution performances, and enables an interesting mode of selective area decryption due to the parallel character of the approach.
On-demand stereoscopic 3D displays for avionic and military applications
NASA Astrophysics Data System (ADS)
Sarma, Kalluri; Lu, Kanghua; Larson, Brent; Schmidt, John; Cupero, Frank
2010-04-01
High speed AM LCD flat panels are evaluated for use in Field Sequential Stereoscopic (FSS) 3D displays for military and avionic applications. A 120 Hz AM LCD is used in field-sequential mode for constructing eyewear-based as well as autostereoscopic 3D display demonstrators for test and evaluation. The COTS eyewear-based system uses shutter glasses to control left-eye/right-eye images. The autostereoscopic system uses a custom backlight to generate illuminating pupils for left and right eyes. It is driven in synchronization with the images on the LCD. Both displays provide 3D effect in full-color and full-resolution in the AM LCD flat panel. We have realized luminance greater than 200 fL in 3D mode with the autostereoscopic system for sunlight readability. The characterization results and performance attributes of both systems are described.
Optimal trajectories for aeroassisted orbital transfer
NASA Technical Reports Server (NTRS)
Miele, A.; Venkataraman, P.
1983-01-01
Consideration is given to classical and minimax problems involved in aeroassisted transfer from high earth orbit (HEO) to low earth orbit (LEO). The transfer is restricted to coplanar operation, with trajectory control effected by means of lift modulation. The performance of the maneuver is indexed to the energy expenditure or, alternatively, the time integral of the heating rate. Firist-order optimality conditions are defined for the classical approach, as are a sequential gradient-restoration algorithm and a combined gradient-restoration algorithm. Minimization techniques are presented for the aeroassisted transfer energy consumption and time-delay integral of the heating rate, as well as minimization of the pressure. It is shown that the eigenvalues of the Jacobian matrix of the differential system is both stiff and unstable, implying that the sequential gradient restoration algorithm in its present version is unsuitable. A new method, involving a multipoint approach to the two-poing boundary value problem, is recommended.
[Reflex epilepsy evoked by decision making: report of a case (author's transl)].
Mutani, R; Ganga, A; Agnetti, V
1980-01-01
A 17-year-old girl with a story of Gran Mal attacks occurring during lessons of mathematics or solving mathematical problems, was investigated with prolonged EEG recordings. During the sessions, relax periods were alternated with arithmetical or mathematical testing, with card or checkers games and solution of puzzles and crossword problems, and with different neuropsychological tests. EGG recordings were characterized by the appearance, on a normal background, of bilaterally synchronous and symmetrical spike-and-wave and polispike-and-wave discharges, associated with loss of consciousness. During relax their mean frequency was one/54 min., it doubled during execution of tests involved with nonsequential decision making, and was eight times as high (one/7 min.) during tests involving sequential decision making. Some tension, challenge and complexity of the performance were also important as precipitating factors. Their lack deprived sequential tests of their efficacy, while on the contrary their presence sometimes gave nonsequential tests full efficacy.
Control of Task Sequences: What is the Role of Language?
Mayr, Ulrich; Kleffner, Killian; Kikumoto, Atsushi; Redford, Melissa A.
2015-01-01
It is almost a truism that language aids serial-order control through self-cuing of upcoming sequential elements. We measured speech onset latencies as subjects performed hierarchically organized task sequences while "thinking aloud" each task label. Surprisingly, speech onset latencies and response times (RTs) were highly synchronized, a pattern that is not consistent with the hypothesis that speaking aids proactive retrieval of upcoming sequential elements during serial-order control. We also found that when instructed to do so, participants were able to speak task labels prior to presentation of response-relevant stimuli and that this substantially reduced RT signatures of retrieval—however at the cost of more sequencing errors. Thus, while proactive retrieval is possible in principle, in natural situations it seems to be prevented through a strong, "gestalt-like" tendency to synchronize speech and action. We suggest that this tendency may support context updating rather than proactive control. PMID:24274386
Validation of antibiotic residue tests for dairy goats.
Zeng, S S; Hart, S; Escobar, E N; Tesfai, K
1998-03-01
The SNAP test, LacTek test (B-L and CEF), Charm Bacillus sterothermophilus var. calidolactis disk assay (BsDA), and Charm II Tablet Beta-lactam sequential test were validated using antibiotic-fortified and -incurred goat milk following the protocol for test kit validations of the U.S. Food and Drug Administration Center for Veterinary Medicine. SNAP, Charm BsDA, and Charm II Tablet Sequential tests were sensitive and reliable in detecting antibiotic residues in goat milk. All three assays showed greater than 90% sensitivity and specificity at tolerance and detection levels. However, caution should be taken in interpreting test results at detection levels. Because of the high sensitivity of these three tests, false-violative results could be obtained in goat milk containing antibiotic residues below the tolerance level. Goat milk testing positive by these tests must be confirmed using a more sophisticated methodology, such as high-performance liquid chromatography, before the milk is condemned. LacTek B-L test did not detect several antibiotics, including penicillin G, in goat milk at tolerance levels. However, LacTek CEF was excellent in detecting ceftiofur residue in goat milk.
Computer vision for driver assistance systems
NASA Astrophysics Data System (ADS)
Handmann, Uwe; Kalinke, Thomas; Tzomakas, Christos; Werner, Martin; von Seelen, Werner
1998-07-01
Systems for automated image analysis are useful for a variety of tasks and their importance is still increasing due to technological advances and an increase of social acceptance. Especially in the field of driver assistance systems the progress in science has reached a level of high performance. Fully or partly autonomously guided vehicles, particularly for road-based traffic, pose high demands on the development of reliable algorithms due to the conditions imposed by natural environments. At the Institut fur Neuroinformatik, methods for analyzing driving relevant scenes by computer vision are developed in cooperation with several partners from the automobile industry. We introduce a system which extracts the important information from an image taken by a CCD camera installed at the rear view mirror in a car. The approach consists of a sequential and a parallel sensor and information processing. Three main tasks namely the initial segmentation (object detection), the object tracking and the object classification are realized by integration in the sequential branch and by fusion in the parallel branch. The main gain of this approach is given by the integrative coupling of different algorithms providing partly redundant information.
Observation of non-classical correlations in sequential measurements of photon polarization
NASA Astrophysics Data System (ADS)
Suzuki, Yutaro; Iinuma, Masataka; Hofmann, Holger F.
2016-10-01
A sequential measurement of two non-commuting quantum observables results in a joint probability distribution for all output combinations that can be explained in terms of an initial joint quasi-probability of the non-commuting observables, modified by the resolution errors and back-action of the initial measurement. Here, we show that the error statistics of a sequential measurement of photon polarization performed at different measurement strengths can be described consistently by an imaginary correlation between the statistics of resolution and back-action. The experimental setup was designed to realize variable strength measurements with well-controlled imaginary correlation between the statistical errors caused by the initial measurement of diagonal polarizations, followed by a precise measurement of the horizontal/vertical polarization. We perform the experimental characterization of an elliptically polarized input state and show that the same complex joint probability distribution is obtained at any measurement strength.
Enhancing lineup identification accuracy: two codes are better than one.
Melara, R D; DeWitt-Rickards, T S; O'Brien, T P
1989-10-01
Ways of improving identification accuracy were explored by comparing the conventional visual lineup with an auditory/visual lineup, one that paired color photographs with voice recordings. This bimodal lineup necessitated sequential presentation of lineup members; Experiment 1 showed that performance in sequential lineups was better than performance in traditional simultaneous lineups. In Experiments 2A and 2B unimodal and bimodal lineups were compared by using a multiple-lineup paradigm: Ss viewed 3 videotaped episodes depicting standard police procedures and were tested in 4 sequential lineups. Bimodal lineups were more diagnostic than either visual or auditory lineups alone. The bimodal lineup led to a 126% improvement in number of correct identifications over the conventional visual lineup, with no concomitant increase in number of false identifications. These results imply strongly that bimodal procedures should be adopted in real-world lineups. The nature of memorial processes underlying this bimodal advantage is discussed.
Brown, Peter; Pullan, Wayne; Yang, Yuedong; Zhou, Yaoqi
2016-02-01
The three dimensional tertiary structure of a protein at near atomic level resolution provides insight alluding to its function and evolution. As protein structure decides its functionality, similarity in structure usually implies similarity in function. As such, structure alignment techniques are often useful in the classifications of protein function. Given the rapidly growing rate of new, experimentally determined structures being made available from repositories such as the Protein Data Bank, fast and accurate computational structure comparison tools are required. This paper presents SPalignNS, a non-sequential protein structure alignment tool using a novel asymmetrical greedy search technique. The performance of SPalignNS was evaluated against existing sequential and non-sequential structure alignment methods by performing trials with commonly used datasets. These benchmark datasets used to gauge alignment accuracy include (i) 9538 pairwise alignments implied by the HOMSTRAD database of homologous proteins; (ii) a subset of 64 difficult alignments from set (i) that have low structure similarity; (iii) 199 pairwise alignments of proteins with similar structure but different topology; and (iv) a subset of 20 pairwise alignments from the RIPC set. SPalignNS is shown to achieve greater alignment accuracy (lower or comparable root-mean squared distance with increased structure overlap coverage) for all datasets, and the highest agreement with reference alignments from the challenging dataset (iv) above, when compared with both sequentially constrained alignments and other non-sequential alignments. SPalignNS was implemented in C++. The source code, binary executable, and a web server version is freely available at: http://sparks-lab.org yaoqi.zhou@griffith.edu.au. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Wenz, Holger; Maros, Máté E; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Groden, Christoph; Henzler, Thomas
2016-01-01
To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1-5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1-5) when compared to sequential cCT with a mean SNR improvement of 44.77% (p < 0.0001). Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.
Avanzino, Laura; Pelosin, Elisa; Martino, Davide; Abbruzzese, Giovanni
2013-01-01
Timing of sequential movements is altered in Parkinson disease (PD). Whether timing deficits in internally generated sequential movements in PD depends also on difficulties in motor planning, rather than merely on a defective ability to materially perform the planned movement is still undefined. To unveil this issue, we adopted a modified version of an established test for motor timing, i.e. the synchronization–continuation paradigm, by introducing a motor imagery task. Motor imagery is thought to involve mainly processes of movement preparation, with reduced involvement of end-stage movement execution-related processes. Fourteen patients with PD and twelve matched healthy volunteers were asked to tap in synchrony with a metronome cue (SYNC) and then, when the tone stopped, to keep tapping, trying to maintain the same rhythm (CONT-EXE) or to imagine tapping at the same rhythm, rather than actually performing it (CONT-MI). We tested both a sub-second and a supra-second inter-stimulus interval between the cues. Performance was recorded using a sensor-engineered glove and analyzed measuring the temporal error and the interval reproduction accuracy index. PD patients were less accurate than healthy subjects in the supra-second time reproduction task when performing both continuation tasks (CONT-MI and CONT-EXE), whereas no difference was detected in the synchronization task and on all tasks involving a sub-second interval. Our findings suggest that PD patients exhibit a selective deficit in motor timing for sequential movements that are separated by a supra-second interval and that this deficit may be explained by a defect of motor planning. Further, we propose that difficulties in motor planning are of a sufficient degree of severity in PD to affect also the motor performance in the supra-second time reproduction task. PMID:24086534
ERIC Educational Resources Information Center
Reeder, Ruth M.; Firszt, Jill B.; Cadieux, Jamie H.; Strube, Michael J.
2017-01-01
Purpose: Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization…
Visible light controls cell adhesion on a photoswitchable biointerface.
Ming, Zunzhen; Hua, Xin; Xue, Yuan; Lin, Qiuning; Bao, Chunyan; Zhu, Linyong
2018-05-04
Bioactive surfaces with specific interactions with cells have been greatly interested due to their potential applications in biosensors and tissue engineering. Herein, we fabricated a dopamine contained photoswitch molecule (compound 1) which could form self-assembled monolayer (SAM) on substrates. The SAM showed a good photoswitch ability and manifested excellent fatigue resistance, which displayed its potential application as a biologically friendly surface coating. Contact angle analysis and cell experiments exhibited that the SAM surface was hydrophobic before irradiation which favored cell adhesion, while, it turned hydrophilic and induced cell unfouling or detachment after light irradiation. The uses of visible light stimulation (λ ex = 530 nm) and the reversible regulation on cell adhesion and detachment should open up new avenues for bioacitve surfaces in biomedical applications. Copyright © 2018 Elsevier B.V. All rights reserved.
DNA-programmed dynamic assembly of quantum dots for molecular computation.
He, Xuewen; Li, Zhi; Chen, Muzi; Ma, Nan
2014-12-22
Despite the widespread use of quantum dots (QDs) for biosensing and bioimaging, QD-based bio-interfaceable and reconfigurable molecular computing systems have not yet been realized. DNA-programmed dynamic assembly of multi-color QDs is presented for the construction of a new class of fluorescence resonance energy transfer (FRET)-based QD computing systems. A complete set of seven elementary logic gates (OR, AND, NOR, NAND, INH, XOR, XNOR) are realized using a series of binary and ternary QD complexes operated by strand displacement reactions. The integration of different logic gates into a half-adder circuit for molecular computation is also demonstrated. This strategy is quite versatile and straightforward for logical operations and would pave the way for QD-biocomputing-based intelligent molecular diagnostics. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
C-learning: A new classification framework to estimate optimal dynamic treatment regimes.
Zhang, Baqun; Zhang, Min
2017-12-11
A dynamic treatment regime is a sequence of decision rules, each corresponding to a decision point, that determine that next treatment based on each individual's own available characteristics and treatment history up to that point. We show that identifying the optimal dynamic treatment regime can be recast as a sequential optimization problem and propose a direct sequential optimization method to estimate the optimal treatment regimes. In particular, at each decision point, the optimization is equivalent to sequentially minimizing a weighted expected misclassification error. Based on this classification perspective, we propose a powerful and flexible C-learning algorithm to learn the optimal dynamic treatment regimes backward sequentially from the last stage until the first stage. C-learning is a direct optimization method that directly targets optimizing decision rules by exploiting powerful optimization/classification techniques and it allows incorporation of patient's characteristics and treatment history to improve performance, hence enjoying advantages of both the traditional outcome regression-based methods (Q- and A-learning) and the more recent direct optimization methods. The superior performance and flexibility of the proposed methods are illustrated through extensive simulation studies. © 2017, The International Biometric Society.
Liou, Jyh-Ming; Chen, Chieh-Chang; Fang, Yu-Jen; Chen, Po-Yueh; Chang, Chi-Yang; Chou, Chu-Kuang; Chen, Mei-Jyh; Tseng, Cheng-Hao; Lee, Ji-Yuh; Yang, Tsung-Hua; Chiu, Min-Chin; Yu, Jian-Jyun; Kuo, Chia-Chi; Luo, Jiing-Chyuan; Hsu, Wen-Feng; Hu, Wen-Hao; Tsai, Min-Horn; Lin, Jaw-Town; Shun, Chia-Tung; Twu, Gary; Lee, Yi-Chia; Bair, Ming-Jong; Wu, Ming-Shiang
2018-05-29
Whether extending the treatment length and the use of high-dose esomeprazole may optimize the efficacy of Helicobacter pylori eradication remains unknown. To compare the efficacy and tolerability of optimized 14 day sequential therapy and 10 day bismuth quadruple therapy containing high-dose esomeprazole in first-line therapy. We recruited 620 adult patients (≥20 years of age) with H. pylori infection naive to treatment in this multicentre, open-label, randomized trial. Patients were randomly assigned to receive 14 day sequential therapy or 10 day bismuth quadruple therapy, both containing esomeprazole 40 mg twice daily. Those who failed after 14 day sequential therapy received rescue therapy with 10 day bismuth quadruple therapy and vice versa. Our primary outcome was the eradication rate in the first-line therapy. Antibiotic susceptibility was determined. ClinicalTrials.gov: NCT03156855. The eradication rates of 14 day sequential therapy and 10 day bismuth quadruple therapy were 91.3% (283 of 310, 95% CI 87.4%-94.1%) and 91.6% (284 of 310, 95% CI 87.8%-94.3%) in the ITT analysis, respectively (difference -0.3%, 95% CI -4.7% to 4.4%, P = 0.886). However, the frequencies of adverse effects were significantly higher in patients treated with 10 day bismuth quadruple therapy than those treated with 14 day sequential therapy (74.4% versus 36.7% P < 0.0001). The eradication rate of 14 day sequential therapy in strains with and without 23S ribosomal RNA mutation was 80% (24 of 30) and 99% (193 of 195), respectively (P < 0.0001). Optimized 14 day sequential therapy was non-inferior to, but better tolerated than 10 day bismuth quadruple therapy and both may be used in first-line treatment in populations with low to intermediate clarithromycin resistance.
Baglivo, Cristina; Congedo, Paolo Maria
2018-04-01
Several technical combinations have been evaluated in order to design high energy performance buildings for the warm climate. The analysis has been developed in several steps, avoiding the use of HVAC systems. The methodological approach of this study is based on a sequential search technique and it is shown on the paper entitled "Envelope Design Optimization by Thermal Modeling of a Building in a Warm Climate" [1]. The Operative Air Temperature trends (TOP), for each combination, have been plotted through a dynamic simulation performed using the software TRNSYS 17 (a transient system simulation program, University of Wisconsin, Solar Energy Laboratory, USA, 2010). Starting from the simplest building configuration consisting of 9 rooms (equal-sized modules of 5 × 5 m 2 ), the different building components are sequentially evaluated until the envelope design is optimized. The aim of this study is to perform a step-by-step simulation, simplifying as much as possible the model without making additional variables that can modify their performances. Walls, slab-on-ground floor, roof, shading and windows are among the simulated building components. The results are shown for each combination and evaluated for Brindisi, a city in southern Italy having 1083 degrees day, belonging to the national climatic zone C. The data show the trends of the TOP for each measure applied in the case study for a total of 17 combinations divided into eight steps.
Kremers, Stef PJ; Vandelanotte, Corneel; van Adrichem, Mathieu JG; Schneider, Francine; Candel, Math JJM; de Vries, Hein
2014-01-01
Background Web-based computer-tailored interventions for multiple health behaviors can have a significant public health impact. Yet, few randomized controlled trials have tested this assumption. Objective The objective of this paper was to test the effects of a sequential and simultaneous Web-based tailored intervention on multiple lifestyle behaviors. Methods A randomized controlled trial was conducted with 3 tailoring conditions (ie, sequential, simultaneous, and control conditions) in the Netherlands in 2009-2012. Follow-up measurements took place after 12 and 24 months. The intervention content was based on the I-Change model. In a health risk appraisal, all respondents (N=5055) received feedback on their lifestyle behaviors that indicated whether they complied with the Dutch guidelines for physical activity, vegetable consumption, fruit consumption, alcohol intake, and smoking. Participants in the sequential (n=1736) and simultaneous (n=1638) conditions received tailored motivational feedback to change unhealthy behaviors one at a time (sequential) or all at the same time (simultaneous). Mixed model analyses were performed as primary analyses; regression analyses were done as sensitivity analyses. An overall risk score was used as outcome measure, then effects on the 5 individual lifestyle behaviors were assessed and a process evaluation was performed regarding exposure to and appreciation of the intervention. Results Both tailoring strategies were associated with small self-reported behavioral changes. The sequential condition had the most significant effects compared to the control condition after 12 months (T1, effect size=0.28). After 24 months (T2), the simultaneous condition was most effective (effect size=0.18). All 5 individual lifestyle behaviors changed over time, but few effects differed significantly between the conditions. At both follow-ups, the sequential condition had significant changes in smoking abstinence compared to the simultaneous condition (T1 effect size=0.31; T2 effect size=0.41). The sequential condition was more effective in decreasing alcohol consumption than the control condition at 24 months (effect size=0.27). Change was predicted by the amount of exposure to the intervention (total visiting time: beta=–.06; P=.01; total number of visits: beta=–.11; P<.001). Both interventions were appreciated well by respondents without significant differences between conditions. Conclusions Although evidence was found for the effectiveness of both programs, no simple conclusive finding could be drawn about which intervention mode was more effective. The best kind of intervention may depend on the behavior that is targeted or on personal preferences and motivation. Further research is needed to identify moderators of intervention effectiveness. The results need to be interpreted in view of the high and selective dropout rates, multiple comparisons, and modest effect sizes. However, a large number of people were reached at low cost and behavioral change was achieved after 2 years. Trial Registration Nederlands Trial Register: NTR 2168; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2168 (Archived by WebCite at http://www.webcitation.org/6MbUqttYB). PMID:24472854
Impact of Temporal Masking of Flip-Flop Upsets on Soft Error Rates of Sequential Circuits
NASA Astrophysics Data System (ADS)
Chen, R. M.; Mahatme, N. N.; Diggins, Z. J.; Wang, L.; Zhang, E. X.; Chen, Y. P.; Liu, Y. N.; Narasimham, B.; Witulski, A. F.; Bhuva, B. L.; Fleetwood, D. M.
2017-08-01
Reductions in single-event (SE) upset (SEU) rates for sequential circuits due to temporal masking effects are evaluated. The impacts of supply voltage, combinational-logic delay, flip-flop (FF) SEU performance, and particle linear energy transfer (LET) values are analyzed for SE cross sections of sequential circuits. Alpha particles and heavy ions with different LET values are used to characterize the circuits fabricated at the 40-nm bulk CMOS technology node. Experimental results show that increasing the delay of the logic circuit present between FFs and decreasing the supply voltage are two effective ways of reducing SE error rates for sequential circuits for particles with low LET values due to temporal masking. SEU-hardened FFs benefit less from temporal masking than conventional FFs. Circuit hardening implications for SEU-hardened and unhardened FFs are discussed.
Rollero, Stephanie; Bloem, Audrey; Ortiz-Julien, Anne; Camarasa, Carole; Divol, Benoit
2018-01-01
The sequential inoculation of non- Saccharomyces yeasts and Saccharomyces cerevisiae in grape juice is becoming an increasingly popular practice to diversify wine styles and/or to obtain more complex wines with a peculiar microbial footprint. One of the main interactions is competition for nutrients, especially nitrogen sources, that directly impacts not only fermentation performance but also the production of aroma compounds. In order to better understand the interactions taking place between non-Saccharomyces yeasts and S. cerevisiae during alcoholic fermentation, sequential inoculations of three yeast species ( Pichia burtonii, Kluyveromyces marxianus, Zygoascus meyerae ) with S. cerevisiae were performed individually in a synthetic medium. Different species-dependent interactions were evidenced. Indeed, the three sequential inoculations resulted in three different behaviors in terms of growth. P. burtonii and Z. meyerae declined after the inoculation of S. cerevisiae which promptly outcompeted the other two species. However, while the presence of P. burtonii did not impact the fermentation kinetics of S. cerevisiae , that of Z. meyerae rendered the overall kinetics very slow and with no clear exponential phase. K. marxianus and S. cerevisiae both declined and became undetectable before fermentation completion. The results also demonstrated that yeasts differed in their preference for nitrogen sources. Unlike Z. meyerae and P. burtonii, K. marxianus appeared to be a competitor for S. cerevisiae (as evidenced by the uptake of ammonium and amino acids), thereby explaining the resulting stuck fermentation. Nevertheless, the results suggested that competition for other nutrients (probably vitamins) occurred during the sequential inoculation of Z. meyerae with S. cerevisiae . The metabolic footprint of the non- Saccharomyces yeasts determined after 48 h of fermentation remained until the end of fermentation and combined with that of S. cerevisiae . For instance, fermentations performed with K. marxianus were characterized by the formation of phenylethanol and phenylethyl acetate, while those performed with P. burtonii or Z. meyerae displayed higher production of isoamyl alcohol and ethyl esters. When considering sequential inoculation of yeasts, the nutritional requirements of the yeasts used should be carefully considered and adjusted accordingly. Finally, our chemical data suggests that the organoleptic properties of the wine are altered in a species specific manner.
Menon, Nadia; White, David; Kemp, Richard I
2015-01-01
According to cognitive and neurological models of the face-processing system, faces are represented at two levels of abstraction. First, image-based pictorial representations code a particular instance of a face and include information that is unrelated to identity-such as lighting, pose, and expression. Second, at a more abstract level, identity-specific representations combine information from various encounters with a single face. Here we tested whether identity-level representations mediate unfamiliar face matching performance. Across three experiments we manipulated identity attributions to pairs of target images and measured the effect on subsequent identification decisions. Participants were instructed that target images were either two photos of the same person (1ID condition) or photos of two different people (2ID condition). This manipulation consistently affected performance in sequential matching: 1ID instructions improved accuracy on "match" trials and caused participants to adopt a more liberal response bias than the 2ID condition. However, this manipulation did not affect performance in simultaneous matching. We conclude that identity-level representations, generated in working memory, influence the amount of variation tolerated between images, when making identity judgements in sequential face matching.
RC64, a Rad-Hard Many-Core High- Performance DSP for Space Applications
NASA Astrophysics Data System (ADS)
Ginosar, Ran; Aviely, Peleg; Gellis, Hagay; Liran, Tuvia; Israeli, Tsvika; Nesher, Roy; Lange, Fredy; Dobkin, Reuven; Meirov, Henri; Reznik, Dror
2015-09-01
RC64, a novel rad-hard 64-core signal processing chip targets DSP performance of 75 GMACs (16bit), 150 GOPS and 38 single precision GFLOPS while dissipating less than 10 Watts. RC64 integrates advanced DSP cores with a multi-bank shared memory and a hardware scheduler, also supporting DDR2/3 memory and twelve 3.125 Gbps full duplex high speed serial links using SpaceFibre and other protocols. The programming model employs sequential fine-grain tasks and a separate task map to define task dependencies. RC64 is implemented as a 300 MHz integrated circuit on a 65nm CMOS technology, assembled in hermetically sealed ceramic CCGA624 package and qualified to the highest space standards.
RC64, a Rad-Hard Many-Core High-Performance DSP for Space Applications
NASA Astrophysics Data System (ADS)
Ginosar, Ran; Aviely, Peleg; Liran, Tuvia; Alon, Dov; Mandler, Alberto; Lange, Fredy; Dobkin, Reuven; Goldberg, Miki
2014-08-01
RC64, a novel rad-hard 64-core signal processing chip targets DSP performance of 75 GMACs (16bit), 150 GOPS and 20 single precision GFLOPS while dissipating less than 10 Watts. RC64 integrates advanced DSP cores with a multi-bank shared memory and a hardware scheduler, also supporting DDR2/3 memory and twelve 2.5 Gbps full duplex high speed serial links using SpaceFibre and other protocols. The programming model employs sequential fine-grain tasks and a separate task map to define task dependencies. RC64 is implemented as a 300 MHz integrated circuit on a 65nm CMOS technology, assembled in hermetically sealed ceramic CCGA624 package and qualified to the highest space standards.
Ruotolo, Francesco; Ruggiero, Gennaro; Vinciguerra, Michela; Iachini, Tina
2012-02-01
The aim of this research is to assess whether the crucial factor in determining the characteristics of blind people's spatial mental images is concerned with the visual impairment per se or the processing style that the dominant perceptual modalities used to acquire spatial information impose, i.e. simultaneous (vision) vs sequential (kinaesthesis). Participants were asked to learn six positions in a large parking area via movement alone (congenitally blind, adventitiously blind, blindfolded sighted) or with vision plus movement (simultaneous sighted, sequential sighted), and then to mentally scan between positions in the path. The crucial manipulation concerned the sequential sighted group. Their visual exploration was made sequential by putting visual obstacles within the pathway in such a way that they could not see simultaneously the positions along the pathway. The results revealed a significant time/distance linear relation in all tested groups. However, the linear component was lower in sequential sighted and blind participants, especially congenital. Sequential sighted and congenitally blind participants showed an almost overlapping performance. Differences between groups became evident when mentally scanning farther distances (more than 5m). This threshold effect could be revealing of processing limitations due to the need of integrating and updating spatial information. Overall, the results suggest that the characteristics of the processing style rather than the visual impairment per se affect blind people's spatial mental images. Copyright © 2011 Elsevier B.V. All rights reserved.
Ego Depletion in Real-Time: An Examination of the Sequential-Task Paradigm.
Arber, Madeleine M; Ireland, Michael J; Feger, Roy; Marrington, Jessica; Tehan, Joshua; Tehan, Gerald
2017-01-01
Current research into self-control that is based on the sequential task methodology is currently at an impasse. The sequential task methodology involves completing a task that is designed to tax self-control resources which in turn has carry-over effects on a second, unrelated task. The current impasse is in large part due to the lack of empirical research that tests explicit assumptions regarding the initial task. Five studies test one key, untested assumption underpinning strength (finite resource) models of self-regulation: Performance will decline over time on a task that depletes self-regulatory resources. In the aftermath of high profile replication failures using a popular letter-crossing task and subsequent criticisms of that task, the current studies examined whether depletion effects would occur in real time using letter-crossing tasks that did not invoke habit-forming and breaking, and whether these effects were moderated by administration type (paper and pencil vs. computer administration). Sample makeup and sizes as well as response formats were also varied across the studies. The five studies yielded a clear and consistent pattern of increasing performance deficits (errors) as a function of time spent on task with generally large effects and in the fifth study the strength of negative transfer effects to a working memory task were related to individual differences in depletion. These results demonstrate that some form of depletion is occurring on letter-crossing tasks though whether an internal regulatory resource reservoir or some other factor is changing across time remains an important question for future research.
Ego Depletion in Real-Time: An Examination of the Sequential-Task Paradigm
Arber, Madeleine M.; Ireland, Michael J.; Feger, Roy; Marrington, Jessica; Tehan, Joshua; Tehan, Gerald
2017-01-01
Current research into self-control that is based on the sequential task methodology is currently at an impasse. The sequential task methodology involves completing a task that is designed to tax self-control resources which in turn has carry-over effects on a second, unrelated task. The current impasse is in large part due to the lack of empirical research that tests explicit assumptions regarding the initial task. Five studies test one key, untested assumption underpinning strength (finite resource) models of self-regulation: Performance will decline over time on a task that depletes self-regulatory resources. In the aftermath of high profile replication failures using a popular letter-crossing task and subsequent criticisms of that task, the current studies examined whether depletion effects would occur in real time using letter-crossing tasks that did not invoke habit-forming and breaking, and whether these effects were moderated by administration type (paper and pencil vs. computer administration). Sample makeup and sizes as well as response formats were also varied across the studies. The five studies yielded a clear and consistent pattern of increasing performance deficits (errors) as a function of time spent on task with generally large effects and in the fifth study the strength of negative transfer effects to a working memory task were related to individual differences in depletion. These results demonstrate that some form of depletion is occurring on letter-crossing tasks though whether an internal regulatory resource reservoir or some other factor is changing across time remains an important question for future research. PMID:29018390
Xia, Xi; Wang, Yuanyuan; Wang, Xia; Li, Yun; Zhong, Feng; Li, Xiaowei; Huang, Yaoling; Ding, Shuangyang; Shen, Jianzhong
2013-05-31
This paper presents a sensitive and confirmatory multi-residue method for the analysis of 23 veterinary drugs and metabolites belonging to three classes (nitroimidazoles, benzimidazoles, and chloramphenicols) in porcine muscle, liver, and kidney. After extracted with ethyl acetate and basic ethyl acetate sequentially, the crude extracts were defatted with hexane and further purified using Oasis MCX solid-phase extraction cartridges. Rapid determination was carried out by ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry. Data acquisition was performed under positive and negative mode simultaneously. Recoveries based on matrix-matched calibrations for meat, liver, and kidney ranged from 50.6 to 108.1%. The method quantification limits were in the range of 3-100ng/kg. Copyright © 2012 Elsevier B.V. All rights reserved.
Recent progress in low-temperature-process monolithic three dimension technology
NASA Astrophysics Data System (ADS)
Yang, Chih-Chao; Hsieh, Tung-Ying; Huang, Wen-Hsien; Shen, Chang-Hong; Shieh, Jia-Min; Yeh, Wen-Kuan; Wu, Meng-Chyi
2018-04-01
Monolithic three-dimension (3D) integration is an ultimate alternative method of fabricating high density, high performance, and multi-functional integrated circuits. It offers the promise of being a new approach to increase system performance. How to manage the thermal impact of multi-tiered processes, such as dopant activation, source/drain silicidation, and channel formation, and to prevent the degradation of pre-existing devices/circuits become key challenges. In this paper, we provide updates on several important monolithic 3D works, particularly in sequentially stackable channels, and our recent achievements in monolithic 3D integrated circuit (3D-IC). These results indicate that the advanced 3D architecture with novel design tools enables ultrahigh-density stackable circuits to have superior performance and low power consumption for future artificial intelligence (AI) and internet of things (IoTs) application.
One-pot growth of two-dimensional lateral heterostructures via sequential edge-epitaxy
NASA Astrophysics Data System (ADS)
Sahoo, Prasana K.; Memaran, Shahriar; Xin, Yan; Balicas, Luis; Gutiérrez, Humberto R.
2018-01-01
Two-dimensional heterojunctions of transition-metal dichalcogenides have great potential for application in low-power, high-performance and flexible electro-optical devices, such as tunnelling transistors, light-emitting diodes, photodetectors and photovoltaic cells. Although complex heterostructures have been fabricated via the van der Waals stacking of different two-dimensional materials, the in situ fabrication of high-quality lateral heterostructures with multiple junctions remains a challenge. Transition-metal-dichalcogenide lateral heterostructures have been synthesized via single-step, two-step or multi-step growth processes. However, these methods lack the flexibility to control, in situ, the growth of individual domains. In situ synthesis of multi-junction lateral heterostructures does not require multiple exchanges of sources or reactors, a limitation in previous approaches as it exposes the edges to ambient contamination, compromises the homogeneity of domain size in periodic structures, and results in long processing times. Here we report a one-pot synthetic approach, using a single heterogeneous solid source, for the continuous fabrication of lateral multi-junction heterostructures consisting of monolayers of transition-metal dichalcogenides. The sequential formation of heterojunctions is achieved solely by changing the composition of the reactive gas environment in the presence of water vapour. This enables selective control of the water-induced oxidation and volatilization of each transition-metal precursor, as well as its nucleation on the substrate, leading to sequential edge-epitaxy of distinct transition-metal dichalcogenides. Photoluminescence maps confirm the sequential spatial modulation of the bandgap, and atomic-resolution images reveal defect-free lateral connectivity between the different transition-metal-dichalcogenide domains within a single crystal structure. Electrical transport measurements revealed diode-like responses across the junctions. Our new approach offers greater flexibility and control than previous methods for continuous growth of transition-metal-dichalcogenide-based multi-junction lateral heterostructures. These findings could be extended to other families of two-dimensional materials, and establish a foundation for the development of complex and atomically thin in-plane superlattices, devices and integrated circuits.
Reuse of imputed data in microarray analysis increases imputation efficiency
Kim, Ki-Yeol; Kim, Byoung-Jin; Yi, Gwan-Su
2004-01-01
Background The imputation of missing values is necessary for the efficient use of DNA microarray data, because many clustering algorithms and some statistical analysis require a complete data set. A few imputation methods for DNA microarray data have been introduced, but the efficiency of the methods was low and the validity of imputed values in these methods had not been fully checked. Results We developed a new cluster-based imputation method called sequential K-nearest neighbor (SKNN) method. This imputes the missing values sequentially from the gene having least missing values, and uses the imputed values for the later imputation. Although it uses the imputed values, the efficiency of this new method is greatly improved in its accuracy and computational complexity over the conventional KNN-based method and other methods based on maximum likelihood estimation. The performance of SKNN was in particular higher than other imputation methods for the data with high missing rates and large number of experiments. Application of Expectation Maximization (EM) to the SKNN method improved the accuracy, but increased computational time proportional to the number of iterations. The Multiple Imputation (MI) method, which is well known but not applied previously to microarray data, showed a similarly high accuracy as the SKNN method, with slightly higher dependency on the types of data sets. Conclusions Sequential reuse of imputed data in KNN-based imputation greatly increases the efficiency of imputation. The SKNN method should be practically useful to save the data of some microarray experiments which have high amounts of missing entries. The SKNN method generates reliable imputed values which can be used for further cluster-based analysis of microarray data. PMID:15504240
Lanczos eigensolution method for high-performance computers
NASA Technical Reports Server (NTRS)
Bostic, Susan W.
1991-01-01
The theory, computational analysis, and applications are presented of a Lanczos algorithm on high performance computers. The computationally intensive steps of the algorithm are identified as: the matrix factorization, the forward/backward equation solution, and the matrix vector multiples. These computational steps are optimized to exploit the vector and parallel capabilities of high performance computers. The savings in computational time from applying optimization techniques such as: variable band and sparse data storage and access, loop unrolling, use of local memory, and compiler directives are presented. Two large scale structural analysis applications are described: the buckling of a composite blade stiffened panel with a cutout, and the vibration analysis of a high speed civil transport. The sequential computational time for the panel problem executed on a CONVEX computer of 181.6 seconds was decreased to 14.1 seconds with the optimized vector algorithm. The best computational time of 23 seconds for the transport problem with 17,000 degs of freedom was on the the Cray-YMP using an average of 3.63 processors.
Lin, Carol Y; Li, Ling
2016-11-07
HPV DNA diagnostic tests for epidemiology monitoring (research purpose) or cervical cancer screening (clinical purpose) have often been considered separately. Women with positive Linear Array (LA) polymerase chain reaction (PCR) research test results typically are neither informed nor referred for colposcopy. Recently, a sequential testing by using Hybrid Capture 2 (HC2) HPV clinical test as a triage before genotype by LA has been adopted for monitoring HPV infections. Also, HC2 has been reported as a more feasible screening approach for cervical cancer in low-resource countries. Thus, knowing the performance of testing strategies incorporating HPV clinical test (i.e., HC2-only or using HC2 as a triage before genotype by LA) compared with LA-only testing in measuring HPV prevalence will be informative for public health practice. We conducted a Monte Carlo simulation study. Data were generated using mathematical algorithms. We designated the reported HPV infection prevalence in the U.S. and Latin America as the "true" underlying type-specific HPV prevalence. Analytical sensitivity of HC2 for detecting 14 high-risk (oncogenic) types was considered to be less than LA. Estimated-to-true prevalence ratios and percentage reductions were calculated. When the "true" HPV prevalence was designated as the reported prevalence in the U.S., with LA genotyping sensitivity and specificity of (0.95, 0.95), estimated-to-true prevalence ratios of 14 high-risk types were 2.132, 1.056, 0.958 for LA-only, HC2-only, and sequential testing, respectively. Estimated-to-true prevalence ratios of two vaccine-associated high-risk types were 2.359 and 1.063 for LA-only and sequential testing, respectively. When designated type-specific prevalence of HPV16 and 18 were reduced by 50 %, using either LA-only or sequential testing, prevalence estimates were reduced by 18 %. Estimated-to-true HPV infection prevalence ratios using LA-only testing strategy are generally higher than using HC2-only or using HC2 as a triage before genotype by LA. HPV clinical testing can be incorporated to monitor HPV prevalence or vaccine effectiveness. Caution is needed when comparing apparent prevalence from different testing strategies.
Kumar, B Senthil; Venkataramasubramanian, V; Sudalai, Arumugam
2012-05-18
A tandem reaction of in situ generated α-amino aldehydes with dimethyloxosulfonium methylide under Corey-Chaykovsky reaction conditions proceeds efficiently to give 4-hydroxypyrazolidine derivatives in high yields with excellent enantio- and diastereoselectivities. This organocatalytic sequential method provides for the efficient synthesis of anti-1,2-aminoalcohols, structural subunits present in several bioactive molecules as well.
Multifunctional picoliter droplet manipulation platform and its application in single cell analysis.
Gu, Shu-Qing; Zhang, Yun-Xia; Zhu, Ying; Du, Wen-Bin; Yao, Bo; Fang, Qun
2011-10-01
We developed an automated and multifunctional microfluidic platform based on DropLab to perform flexible generation and complex manipulations of picoliter-scale droplets. Multiple manipulations including precise droplet generation, sequential reagent merging, and multistep solid-phase extraction for picoliter-scale droplets could be achieved in the present platform. The system precision in generating picoliter-scale droplets was significantly improved by minimizing the thermo-induced fluctuation of flow rate. A novel droplet fusion technique based on the difference of droplet interfacial tensions was developed without the need of special microchannel networks or external devices. It enabled sequential addition of reagents to droplets on demand for multistep reactions. We also developed an effective picoliter-scale droplet splitting technique with magnetic actuation. The difficulty in phase separation of magnetic beads from picoliter-scale droplets due to the high interfacial tension was overcome using ferromagnetic particles to carry the magnetic beads to pass through the phase interface. With this technique, multistep solid-phase extraction was achieved among picoliter-scale droplets. The present platform had the ability to perform complex multistep manipulations to picoliter-scale droplets, which is particularly required for single cell analysis. Its utility and potentials in single cell analysis were preliminarily demonstrated in achieving high-efficiency single-cell encapsulation, enzyme activity assay at the single cell level, and especially, single cell DNA purification based on solid-phase extraction.
Sequentially evaporated thin film YBa2Cu3O(7-x) superconducting microwave ring resonator
NASA Technical Reports Server (NTRS)
Rohrer, Norman J.; To, Hing Y.; Valco, George J.; Bhasin, Kul B.; Chorey, Chris; Warner, Joseph D.
1990-01-01
There is great interest in the application of thin film high temperature superconductors in high frequency electronic circuits. A ring resonator provides a good test vehicle for assessing the microwave losses in the superconductor and for comparing films made by different techniques. Ring resonators made of YBa2Cu3O(7-x) have been investigated on LaAlO3 substrates. The superconducting thin films were deposited by sequential electron beam evaporation of Cu, Y, and BaF2 with a post anneal. Patterning of the superconducting film was done using negative photolithography. A ring resonator was also fabricated from a thin gold film as a control. Both resonators had a gold ground plane on the backside of the substrate. The ring resonators' reflection coefficients were measured as a function of frequency from 33 to 37 GHz at temperatures ranging from 20 K to 68 K. The resonator exhibited two resonances which were at 34.5 and 35.7 GHz at 68 K. The resonant frequencies increased with decreasing temperature. The magnitude of the reflection coefficients was in the calculation of the unloaded Q-values. The performance of the evaporated and gold resonator are compared with the performance of a laser ablated YBa2Cu3O(7-x) resonator. The causes of the double resonance are discussed.
Rantsiou, Kalliopi; Dolci, Paola; Giacosa, Simone; Torchio, Fabrizio; Tofalo, Rosanna; Torriani, Sandra; Suzzi, Giovanna; Rolle, Luca; Cocolin, Luca
2012-03-01
In this study we investigated the possibility of using Candida zemplinina, as a partner of Saccharomyces cerevisiae, in mixed fermentations of must with a high sugar content, in order to reduce its acetic acid production. Thirty-five C. zemplinina strains, which were isolated from different geographic regions, were molecularly characterized, and their fermentation performances were determined. Five genetically different strains were selected for mixed fermentations with S. cerevisiae. Two types of inoculation were carried out: coinoculation and sequential inoculation. A balance between the two species was generally observed for the first 6 days, after which the levels of C. zemplinina started to decrease. Relevant differences were observed concerning the consumption of sugars, the ethanol and glycerol content, and acetic acid production, depending on which strain was used and which type of inoculation was performed. Sequential inoculation led to the reduction of about half of the acetic acid content compared to the pure S. cerevisiae fermentation, but the ethanol and glycerol amounts were also low. A coinoculation with selected combinations of S. cerevisiae and C. zemplinina resulted in a decrease of ~0.3 g of acetic acid/liter, while maintaining high ethanol and glycerol levels. This study demonstrates that mixed S. cerevisiae and C. zemplinina fermentation could be applied in sweet wine fermentation to reduce the production of acetic acid, connected to the S. cerevisiae osmotic stress response.
Wang, Nelson; Qian, Pierre; Kumar, Shejil; Yan, Tristan D; Phan, Kevin
2016-04-15
There have been a myriad of studies investigating the effectiveness of N-acetylcysteine (NAC) in the prevention of contrast induced nephropathy (CIN) in patients undergoing coronary angiography (CAG) with or without percutaneous coronary intervention (PCI). However the consensus is still out about the effectiveness of NAC pre-treatment due to vastly mixed results amongst the literature. The aim of this study was to conduct a meta-analysis and trial sequential analysis to determine the effects of pre-operative NAC in lowering the incidence of CIN in patients undergoing CAG and/or PCI. A systematic literature search was performed to include all randomized controlled trials (RCTs) comparing NAC versus control as pretreatment for CAG and/or PCI. A traditional meta-analysis and several subgroup analyses were conducted using traditional meta-analysis with relative risk (RR), trial sequential analysis, and meta-regression analysis. 43 RCTs met our inclusion criteria giving a total of 3277 patients in both control and treatment arms. There was a significant reduction in the risk of CIN in the NAC treated group compared to control (OR 0.666; 95% CI, 0.532-0.834; I2=40.11%; p=0.004). Trial sequential analysis, using a relative risk reduction threshold of 15%, indicates that the evidence is firm. The results of the present paper support the use of NAC in the prevention of CIN in patients undergoing CAG±PCI. Future studies should focus on the benefits of NAC amongst subgroups of high-risk patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Odéen, Henrik; Todd, Nick; Diakite, Mahamadou; Minalga, Emilee; Payne, Allison; Parker, Dennis L.
2014-01-01
Purpose: To investigate k-space subsampling strategies to achieve fast, large field-of-view (FOV) temperature monitoring using segmented echo planar imaging (EPI) proton resonance frequency shift thermometry for MR guided high intensity focused ultrasound (MRgHIFU) applications. Methods: Five different k-space sampling approaches were investigated, varying sample spacing (equally vs nonequally spaced within the echo train), sampling density (variable sampling density in zero, one, and two dimensions), and utilizing sequential or centric sampling. Three of the schemes utilized sequential sampling with the sampling density varied in zero, one, and two dimensions, to investigate sampling the k-space center more frequently. Two of the schemes utilized centric sampling to acquire the k-space center with a longer echo time for improved phase measurements, and vary the sampling density in zero and two dimensions, respectively. Phantom experiments and a theoretical point spread function analysis were performed to investigate their performance. Variable density sampling in zero and two dimensions was also implemented in a non-EPI GRE pulse sequence for comparison. All subsampled data were reconstructed with a previously described temporally constrained reconstruction (TCR) algorithm. Results: The accuracy of each sampling strategy in measuring the temperature rise in the HIFU focal spot was measured in terms of the root-mean-square-error (RMSE) compared to fully sampled “truth.” For the schemes utilizing sequential sampling, the accuracy was found to improve with the dimensionality of the variable density sampling, giving values of 0.65 °C, 0.49 °C, and 0.35 °C for density variation in zero, one, and two dimensions, respectively. The schemes utilizing centric sampling were found to underestimate the temperature rise, with RMSE values of 1.05 °C and 1.31 °C, for variable density sampling in zero and two dimensions, respectively. Similar subsampling schemes with variable density sampling implemented in zero and two dimensions in a non-EPI GRE pulse sequence both resulted in accurate temperature measurements (RMSE of 0.70 °C and 0.63 °C, respectively). With sequential sampling in the described EPI implementation, temperature monitoring over a 192 × 144 × 135 mm3 FOV with a temporal resolution of 3.6 s was achieved, while keeping the RMSE compared to fully sampled “truth” below 0.35 °C. Conclusions: When segmented EPI readouts are used in conjunction with k-space subsampling for MR thermometry applications, sampling schemes with sequential sampling, with or without variable density sampling, obtain accurate phase and temperature measurements when using a TCR reconstruction algorithm. Improved temperature measurement accuracy can be achieved with variable density sampling. Centric sampling leads to phase bias, resulting in temperature underestimations. PMID:25186406
Extremely accurate sequential verification of RELAP5-3D
Mesina, George L.; Aumiller, David L.; Buschman, Francis X.
2015-11-19
Large computer programs like RELAP5-3D solve complex systems of governing, closure and special process equations to model the underlying physics of nuclear power plants. Further, these programs incorporate many other features for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. For RELAP5-3D, verification and validation are restricted to nuclear power plant applications. Verification means ensuring that the program is built right by checking that it meets its design specifications, comparing coding to algorithms and equations and comparing calculations against analytical solutions and method ofmore » manufactured solutions. Sequential verification performs these comparisons initially, but thereafter only compares code calculations between consecutive code versions to demonstrate that no unintended changes have been introduced. Recently, an automated, highly accurate sequential verification method has been developed for RELAP5-3D. The method also provides to test that no unintended consequences result from code development in the following code capabilities: repeating a timestep advancement, continuing a run from a restart file, multiple cases in a single code execution, and modes of coupled/uncoupled operation. In conclusion, mathematical analyses of the adequacy of the checks used in the comparisons are provided.« less
El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef
2016-01-01
Aim. To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods. 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results. All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P < 0.001). A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions. WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure. PMID:28127465
Abou Samra, Waleed Ali; El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef
2016-01-01
Aim . To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods . 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results . All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P < 0.001). A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions . WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure.
Puertas, B; Jiménez, M J; Cantos-Villar, E; Cantoral, J M; Rodríguez, M E
2017-03-01
We have evaluated for the first time the impact of two commercial yeast strains (Torulaspora delbrueckii TD291 and Saccharomyces cerevisiae QA23) inoculated sequentially in musts of Chardonnay and Palomino Fino grape varieties grown under warm climate (South-west of Spain). Semi-industrial scale alcoholic fermentations (AF) were performed during the 2011 and 2012 harvests. Implantation analyses demonstrated that T. delbrueckii is the predominant strain until the end of the AF phase. Wines with sequential inoculation (SI) resulted in the production of low levels of acetic acid (which gives wine an undesirable 'vinegary' character), low acetaldehyde in Chardonnay and high in Palomino wines. The most salient attributes that contribute to the quality of the Chardonnay and Palomino wines produced were aroma intensity, fresh and tropical fruit character. This study demonstrated that SI of T. delbrueckii and S. cerevisiae contribute significantly to the improvement of Chardonnay wine aromas and the creation of new styles of wine for Palomino. This study has generated new knowledge about the biotechnological potential of T. delbrueckii (TD219) and S. cerevisiae (QA23) for improving the organoleptic properties of Chardonnay and Palomino wines. © 2016 The Society for Applied Microbiology.
Novel Designs of Quantum Reversible Counters
NASA Astrophysics Data System (ADS)
Qi, Xuemei; Zhu, Haihong; Chen, Fulong; Zhu, Junru; Zhang, Ziyang
2016-11-01
Reversible logic, as an interesting and important issue, has been widely used in designing combinational and sequential circuits for low-power and high-speed computation. Though a significant number of works have been done on reversible combinational logic, the realization of reversible sequential circuit is still at premature stage. Reversible counter is not only an important part of the sequential circuit but also an essential part of the quantum circuit system. In this paper, we designed two kinds of novel reversible counters. In order to construct counter, the innovative reversible T Flip-flop Gate (TFG), T Flip-flop block (T_FF) and JK flip-flop block (JK_FF) are proposed. Based on the above blocks and some existing reversible gates, the 4-bit binary-coded decimal (BCD) counter and controlled Up/Down synchronous counter are designed. With the help of Verilog hardware description language (Verilog HDL), these counters above have been modeled and confirmed. According to the simulation results, our circuits' logic structures are validated. Compared to the existing ones in terms of quantum cost (QC), delay (DL) and garbage outputs (GBO), it can be concluded that our designs perform better than the others. There is no doubt that they can be used as a kind of important storage components to be applied in future low-power computing systems.
SSME propellant path leak detection real-time
NASA Technical Reports Server (NTRS)
Crawford, R. A.; Smith, L. M.
1994-01-01
Included are four documents that outline the technical aspects of the research performed on NASA Grant NAG8-140: 'A System for Sequential Step Detection with Application to Video Image Processing'; 'Leak Detection from the SSME Using Sequential Image Processing'; 'Digital Image Processor Specifications for Real-Time SSME Leak Detection'; and 'A Color Change Detection System for Video Signals with Applications to Spectral Analysis of Rocket Engine Plumes'.
ERIC Educational Resources Information Center
Cacola, Priscila; Roberson, Jerroed; Gabbard, Carl
2013-01-01
Studies show that as we enter older adulthood (greater than 64 years), our ability to mentally represent action in the form of using motor imagery declines. Using a chronometry paradigm to compare the movement duration of imagined and executed movements, we tested young-, middle-aged, and older adults on their ability to perform sequential finger…
Wild, Aaron T; Gandhi, Nishant; Chettiar, Sivarajan T; Aziz, Khaled; Gajula, Rajendra P; Williams, Russell D; Kumar, Rachit; Taparra, Kekoa; Zeng, Jing; Cades, Jessica A; Velarde, Esteban; Menon, Siddharth; Geschwind, Jean F; Cosgrove, David; Pawlik, Timothy M; Maitra, Anirban; Wong, John; Hales, Russell K; Torbenson, Michael S; Herman, Joseph M; Tran, Phuoc T
2013-01-01
Sorafenib (SOR) is the only systemic agent known to improve survival for hepatocellular carcinoma (HCC). However, SOR prolongs survival by less than 3 months and does not alter symptomatic progression. To improve outcomes, several phase I-II trials are currently examining SOR with radiation (RT) for HCC utilizing heterogeneous concurrent and sequential treatment regimens. Our study provides preclinical data characterizing the effects of concurrent versus sequential RT-SOR on HCC cells both in vitro and in vivo. Concurrent and sequential RT-SOR regimens were tested for efficacy among 4 HCC cell lines in vitro by assessment of clonogenic survival, apoptosis, cell cycle distribution, and γ-H2AX foci formation. Results were confirmed in vivo by evaluating tumor growth delay and performing immunofluorescence staining in a hind-flank xenograft model. In vitro, concurrent RT-SOR produced radioprotection in 3 of 4 cell lines, whereas sequential RT-SOR produced decreased colony formation among all 4. Sequential RT-SOR increased apoptosis compared to RT alone, while concurrent RT-SOR did not. Sorafenib induced reassortment into less radiosensitive phases of the cell cycle through G1-S delay and cell cycle slowing. More double-strand breaks (DSBs) persisted 24 h post-irradiation for RT alone versus concurrent RT-SOR. In vivo, sequential RT-SOR produced the greatest tumor growth delay, while concurrent RT-SOR was similar to RT alone. More persistent DSBs were observed in xenografts treated with sequential RT-SOR or RT alone versus concurrent RT-SOR. Sequential RT-SOR additionally produced a greater reduction in xenograft tumor vascularity and mitotic index than either concurrent RT-SOR or RT alone. In conclusion, sequential RT-SOR demonstrates greater efficacy against HCC than concurrent RT-SOR both in vitro and in vivo. These results may have implications for clinical decision-making and prospective trial design.
Chettiar, Sivarajan T.; Aziz, Khaled; Gajula, Rajendra P.; Williams, Russell D.; Kumar, Rachit; Taparra, Kekoa; Zeng, Jing; Cades, Jessica A.; Velarde, Esteban; Menon, Siddharth; Geschwind, Jean F.; Cosgrove, David; Pawlik, Timothy M.; Maitra, Anirban; Wong, John; Hales, Russell K.; Torbenson, Michael S.; Herman, Joseph M.; Tran, Phuoc T.
2013-01-01
Sorafenib (SOR) is the only systemic agent known to improve survival for hepatocellular carcinoma (HCC). However, SOR prolongs survival by less than 3 months and does not alter symptomatic progression. To improve outcomes, several phase I-II trials are currently examining SOR with radiation (RT) for HCC utilizing heterogeneous concurrent and sequential treatment regimens. Our study provides preclinical data characterizing the effects of concurrent versus sequential RT-SOR on HCC cells both in vitro and in vivo. Concurrent and sequential RT-SOR regimens were tested for efficacy among 4 HCC cell lines in vitro by assessment of clonogenic survival, apoptosis, cell cycle distribution, and γ-H2AX foci formation. Results were confirmed in vivo by evaluating tumor growth delay and performing immunofluorescence staining in a hind-flank xenograft model. In vitro, concurrent RT-SOR produced radioprotection in 3 of 4 cell lines, whereas sequential RT-SOR produced decreased colony formation among all 4. Sequential RT-SOR increased apoptosis compared to RT alone, while concurrent RT-SOR did not. Sorafenib induced reassortment into less radiosensitive phases of the cell cycle through G1-S delay and cell cycle slowing. More double-strand breaks (DSBs) persisted 24 h post-irradiation for RT alone versus concurrent RT-SOR. In vivo, sequential RT-SOR produced the greatest tumor growth delay, while concurrent RT-SOR was similar to RT alone. More persistent DSBs were observed in xenografts treated with sequential RT-SOR or RT alone versus concurrent RT-SOR. Sequential RT-SOR additionally produced a greater reduction in xenograft tumor vascularity and mitotic index than either concurrent RT-SOR or RT alone. In conclusion, sequential RT-SOR demonstrates greater efficacy against HCC than concurrent RT-SOR both in vitro and in vivo. These results may have implications for clinical decision-making and prospective trial design. PMID:23762417
Nasa, Mukesh; Choksey, Ajay; Phadke, Aniruddha; Sawant, Prabha
2013-11-01
Antimicrobial resistance has decreased eradication rates for Helicobacter pylori infection worldwide. A sequential treatment schedule has been reported to be effective, but studies published to date were performed in Italy. We undertook this study to determine whether these results could be replicated in India. A randomized, open-labeled, prospective controlled trial comparing sequential vs. standard triple-drug therapy was carried out at Lokmanya Tilak Municipal General Hospital, Mumbai. Two hundred and thirty-one patients with dyspepsia were randomized to a 10-day sequential regimen (40 mg of pantoprazole, 1 g of amoxicillin, each administered twice daily for the first 5 days, followed by 40 mg of pantoprazole, 500 mg of clarithromycin, and 500 mg of tinidazole, each administered twice daily for the remaining 5 days) or to standard 14-day therapy (40 mg of pantoprazole, 500 mg of clarithromycin, and 1 g of amoxicillin, each administered twice daily). The eradication rate achieved with the sequential regimen was significantly greater than that obtained with the triple therapy. Per-protocol eradication rate of sequential therapy was 92.4% (95% CI 85.8-96.1%) vs. 81.8% (95% CI 73.9-87.8%) (p = 0.027) for standard drug therapy. Intention-to-treat eradication rates were 88.2% (95% CI 80.9-93.0%) vs. 79.1% (95% CI 71.1-85.4%), p = 0.029, respectively. The incidence of major and minor side effects between therapy groups was not significantly different (14.6% in the triple therapy group vs. 23.5% in sequential group, p = 0.12). Follow up was incomplete in 3.3% and 4.7% patients in standard and sequential therapy groups, respectively. Sequential therapy includes one additional antibiotic (tinidazole) that is not contained in standard therapy. Sequential therapy was significantly better than standard therapy for eradicating H. pylori infection.
Vapor Grown Perovskite Solar Cells
NASA Astrophysics Data System (ADS)
Abdussamad Abbas, Hisham
Perovskite solar cells has been the fastest growing solar cell material till date with verified efficiencies of over 22%. Most groups in the world focuses their research on solution based devices that has residual solvent in the material bulk. This work focuses extensively on the fabrication and properties of vapor based perovskite devices that is devoid of solvents. The initial part of my work focuses on the detailed fabrication of high efficiency consistent sequential vapor NIP devices made using P3HT as P-type Type II heterojunction. The sequential vapor devices experiences device anomalies like voltage evolution and IV hysteresis owing to charge trapping in TiO2. Hence, sequential PIN devices were fabricated using doped Type-II heterojunctions that had no device anomalies. The sequential PIN devices has processing restriction, as organic Type-II heterojunction materials cannot withstand high processing temperature, hence limiting device efficiency. Thereby bringing the need of co-evaporation for fabricating high efficiency consistent PIN devices, the approach has no-restriction on substrates and offers stoichiometric control. A comprehensive description of the fabrication, Co-evaporator setup and how to build it is described. The results of Co-evaporated devices clearly show that grain size, stoichiometry and doped transport layers are all critical for eliminating device anomalies and in fabricating high efficiency devices. Finally, Formamidinium based perovskite were fabricated using sequential approach. A thermal degradation study was conducted on Methyl Ammonium Vs. Formamidinium based perovskite films, Formamidinium based perovskites were found to be more stable. Lastly, inorganic films such as CdS and Nickel oxide were developed in this work.
Engineering of Machine tool’s High-precision electric drives
NASA Astrophysics Data System (ADS)
Khayatov, E. S.; Korzhavin, M. E.; Naumovich, N. I.
2018-03-01
In the article it is shown that in mechanisms with numerical program control, high quality of processes can be achieved only in systems that provide adjustment of the working element’s position with high accuracy, and this requires an expansion of the regulation range by the torque. In particular, the use of synchronous reactive machines with independent excitation control makes it possible to substantially increase the moment overload in the sequential excitation circuit. Using mathematical and physical modeling methods, it is shown that in the electric drive with a synchronous reactive machine with independent excitation in a circuit with sequential excitation, it is possible to significantly expand the range of regulation by the torque and this is achieved by the effect of sequential excitation, which makes it possible to compensate for the transverse reaction of the armature.
Saito, Shota; Hirata, Yoshito; Sasahara, Kazutoshi; Suzuki, Hideyuki
2015-01-01
Micro-blogging services, such as Twitter, offer opportunities to analyse user behaviour. Discovering and distinguishing behavioural patterns in micro-blogging services is valuable. However, it is difficult and challenging to distinguish users, and to track the temporal development of collective attention within distinct user groups in Twitter. In this paper, we formulate this problem as tracking matrices decomposed by Nonnegative Matrix Factorisation for time-sequential matrix data, and propose a novel extension of Nonnegative Matrix Factorisation, which we refer to as Time Evolving Nonnegative Matrix Factorisation (TENMF). In our method, we describe users and words posted in some time interval by a matrix, and use several matrices as time-sequential data. Subsequently, we apply Time Evolving Nonnegative Matrix Factorisation to these time-sequential matrices. TENMF can decompose time-sequential matrices, and can track the connection among decomposed matrices, whereas previous NMF decomposes a matrix into two lower dimension matrices arbitrarily, which might lose the time-sequential connection. Our proposed method has an adequately good performance on artificial data. Moreover, we present several results and insights from experiments using real data from Twitter.
Zhang, Yifan; Gao, Xunzhang; Peng, Xuan; Ye, Jiaqi; Li, Xiang
2018-05-16
The High Resolution Range Profile (HRRP) recognition has attracted great concern in the field of Radar Automatic Target Recognition (RATR). However, traditional HRRP recognition methods failed to model high dimensional sequential data efficiently and have a poor anti-noise ability. To deal with these problems, a novel stochastic neural network model named Attention-based Recurrent Temporal Restricted Boltzmann Machine (ARTRBM) is proposed in this paper. RTRBM is utilized to extract discriminative features and the attention mechanism is adopted to select major features. RTRBM is efficient to model high dimensional HRRP sequences because it can extract the information of temporal and spatial correlation between adjacent HRRPs. The attention mechanism is used in sequential data recognition tasks including machine translation and relation classification, which makes the model pay more attention to the major features of recognition. Therefore, the combination of RTRBM and the attention mechanism makes our model effective for extracting more internal related features and choose the important parts of the extracted features. Additionally, the model performs well with the noise corrupted HRRP data. Experimental results on the Moving and Stationary Target Acquisition and Recognition (MSTAR) dataset show that our proposed model outperforms other traditional methods, which indicates that ARTRBM extracts, selects, and utilizes the correlation information between adjacent HRRPs effectively and is suitable for high dimensional data or noise corrupted data.
A Bayesian sequential processor approach to spectroscopic portal system decisions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sale, K; Candy, J; Breitfeller, E
The development of faster more reliable techniques to detect radioactive contraband in a portal type scenario is an extremely important problem especially in this era of constant terrorist threats. Towards this goal the development of a model-based, Bayesian sequential data processor for the detection problem is discussed. In the sequential processor each datum (detector energy deposit and pulse arrival time) is used to update the posterior probability distribution over the space of model parameters. The nature of the sequential processor approach is that a detection is produced as soon as it is statistically justified by the data rather than waitingmore » for a fixed counting interval before any analysis is performed. In this paper the Bayesian model-based approach, physics and signal processing models and decision functions are discussed along with the first results of our research.« less
Tait, Jamie L; Duckham, Rachel L; Milte, Catherine M; Main, Luana C; Daly, Robin M
2017-01-01
Emerging research indicates that exercise combined with cognitive training may improve cognitive function in older adults. Typically these programs have incorporated sequential training, where exercise and cognitive training are undertaken separately. However, simultaneous or dual-task training, where cognitive and/or motor training are performed simultaneously with exercise, may offer greater benefits. This review summary provides an overview of the effects of combined simultaneous vs. sequential training on cognitive function in older adults. Based on the available evidence, there are inconsistent findings with regard to the cognitive benefits of sequential training in comparison to cognitive or exercise training alone. In contrast, simultaneous training interventions, particularly multimodal exercise programs in combination with secondary tasks regulated by sensory cues, have significantly improved cognition in both healthy older and clinical populations. However, further research is needed to determine the optimal characteristics of a successful simultaneous training program for optimizing cognitive function in older people.
NASA Astrophysics Data System (ADS)
Zhang, Xiaoli; Zou, Jie; Le, Daniel X.; Thoma, George
2010-01-01
"Investigator Names" is a newly required field in MEDLINE citations. It consists of personal names listed as members of corporate organizations in an article. Extracting investigator names automatically is necessary because of the increasing volume of articles reporting collaborative biomedical research in which a large number of investigators participate. In this paper, we present an SVM-based stacked sequential learning method in a novel application - recognizing named entities such as the first and last names of investigators from online medical journal articles. Stacked sequential learning is a meta-learning algorithm which can boost any base learner. It exploits contextual information by adding the predicted labels of the surrounding tokens as features. We apply this method to tag words in text paragraphs containing investigator names, and demonstrate that stacked sequential learning improves the performance of a nonsequential base learner such as an SVM classifier.
Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia
2014-01-01
Abstract Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. Results: The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Conclusions: Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening. PMID:25244081
Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia
2014-10-01
An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.
Performance measurements of the first RAID prototype
NASA Technical Reports Server (NTRS)
Chervenak, Ann L.
1990-01-01
The performance is examined of Redundant Arrays of Inexpensive Disks (RAID) the First, a prototype disk array. A hierarchy of bottlenecks was discovered in the system that limit overall performance. The most serious is the memory system contention on the Sun 4/280 host CPU, which limits array bandwidth to 2.3 MBytes/sec. The array performs more successfully on small random operations, achieving nearly 300 I/Os per second before the Sun 4/280 becomes CPU limited. Other bottlenecks in the system are the VME backplane, bandwidth on the disk controller, and overheads associated with the SCSI protocol. All are examined in detail. The main conclusion is that to achieve the potential bandwidth of arrays, more powerful CPU's alone will not suffice. Just as important are adequate host memory bandwidth and support for high bandwidth on disk controllers. Current disk controllers are more often designed to achieve large numbers of small random operations, rather than high bandwidth. Operating systems also need to change to support high bandwidth from disk arrays. In particular, they should transfer data in larger blocks, and should support asynchronous I/O to improve sequential write performance.
Van Parijs, Hilde; Reynders, Truus; Heuninckx, Karina; Verellen, Dirk; Storme, Guy; De Ridder, Mark
2014-01-01
Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.
Reynders, Truus; Heuninckx, Karina; Verellen, Dirk; Storme, Guy; De Ridder, Mark
2014-01-01
Background. Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. Methods. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. Results. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. Conclusions. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine. PMID:25162031
Wu, Gang; Jiang, Ping; Wei, Jing; Shao, Hongbo
2007-11-15
Biomass and nutrients were investigated in 2003, 2004 and 2005 growing seasons by using a chronosequence of five vegetation types in alpine tundra on Changbai Mountains. The objective of this study was to test whether nutrients at biointerfaces were significant differences among five vegetation types. The biomass and elevation are highly related (biomass=-237.3ln(elevation)+494.36; R(2)=0.8092; p<0.05). There were no significant differences in phosphorus (P) and sulphur (S) concentrations of roots, stems and leaves among five vegetation types while there are significant differences in nitrogen (N) and P stocks of roots, stems and leaves and in S stock of stems and leaves among typical alpine tundra vegetation (TA), meadow alpine tundra vegetation (MA), and swamp alpine tundra vegetation (SA) (p<0.05). Vegetation nutrients stock is averagely 72.46kg hm(-2), and N, P, S stocks are 48.55, 10.33 and 13.61kg hm(-2), respectively. Soil N and S concentrations in MA are significantly higher than those in other four soil types. P is higher in SA (p<0.05). Soil nutrients stock (0-20cm) is averagely 39.59t hm(-2), and N, P, S stocks are 23.74, 5.86 and 9.99t hm(-2), respectively.
A Conformal, Bio-interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology
Viventi, Jonathan; Kim, Dae-Hyeong; Moss, Joshua D.; Kim, Yun-Soung; Blanco, Justin A.; Annetta, Nicholas; Hicks, Andrew; Xiao, Jianliang; Huang, Younggang; Callans, David J.; Rogers, John A.; Litt, Brian
2011-01-01
The sophistication and resolution of current implantable medical devices are limited by the need connect each sensor separately to data acquisition systems. The ability of these devices to sample and modulate tissues is further limited by the rigid, planar nature of the electronics and the electrode-tissue interface. Here, we report the development of a class of mechanically flexible silicon electronics for measuring signals in an intimate, conformal integrated mode on the dynamic, three dimensional surfaces of soft tissues in the human body. We illustrate this technology in sensor systems composed of 2016 silicon nanomembrane transistors configured to record electrical activity directly from the curved, wet surface of a beating heart in vivo. The devices sample with simultaneous sub-millimeter and sub-millisecond resolution through 288 amplified and multiplexed channels. We use these systems to map the spread of spontaneous and paced ventricular depolarization in real time, at high resolution, on the epicardial surface in a porcine animal model. This clinical-scale demonstration represents one example of many possible uses of this technology in minimally invasive medical devices. [Conformal electronics and sensors intimately integrated with living tissues enable a new generation of implantable devices capable of addressing important problems in human health.] PMID:20375008
Versatile graphene biosensors for enhancing human cell therapy.
Vlăsceanu, George M; Amărandi, Roxana-Maria; Ioniță, Mariana; Tite, Teddy; Iovu, Horia; Pilan, Luisa; Burns, Jorge S
2018-05-01
Technological advances in engineering and cell biology stimulate novel approaches for medical treatment, in particular cell-based therapy. The first cell-based gene therapy against cancer was recently approved by the US Food and Drug Administration. Progress in cancer diagnosis includes a blood test detecting five cancer types. Numerous stem cell phase I/II clinical trials showing safety and efficacy will soon pursue qualifying criteria for advanced therapy medicinal products (ATMP), aspiring to join the first stem-cell therapy approved by the European Medicines Agency. Cell based therapy requires extensive preclinical characterisation of biomarkers indicating mechanisms of action crucial to the desired therapeutic effect. Quantitative analyses monitoring critical functions for the manufacture of optimal cell and tissue-based clinical products include successful potency assays for implementation. The challenge to achieve high quality measurement is increasingly met by progress in biosensor design. We adopt a cell therapy perspective to highlight recent examples of graphene-enhanced biointerfaces for measurement of biomarkers relevant to cancer treatment, diagnosis and tissue regeneration. Graphene based biosensor design problems can thwart their use for health care transformative point of care testing and real-time applications. We discuss concerns to be addressed and emerging solutions for establishing clinical grade biosensors to accelerate human cell therapy. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Yaru; Zhang, Bin; Ye, Xiaoli; Yan, Yuqi; Huang, Langhuan; Jiang, Zhenyou; Tan, Shaozao; Cai, Xiang
2016-02-01
Tuberculosis is the most frequent cause of infection-related death worldwide. A new disposable electrochemical immunosensor with low cost and simple fabrication was proposed to detect interferon-γ (IFN-γ). Diallyldimethylammonium chloride (PDDA) and Au nanoparticle (AuNP) composite were used to provide an efficient biointerface, horseradish peroxidase (HRP)-labeled antibody-conjugated AuNP (HRP-Ab2-AuNP) bioconjugates were used as a novel signal tag. The large amounts of HRP on the signal tag can catalyze the oxidation of Hydroquinone (HQ) by H2O2, which can induce an amplified reductive current. The catalytic reduction current was related to the amount of HRP immobilized on the surface, which itself was related to the concentration of IFN-γ. Under optimized conditions, the proposed immunosensor showed a high sensitivity and a linear range of 0.1-10,000pg/mL with a detection limit of 0.048pg/mL. The assay results of clinical serum samples obtained by the immunosensor were in acceptable agreement with the reference values. Therefore, the immunosensor possessed excellent clinical value in early diagnosis and control of tuberculosis. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Rotureau, Elise; Billard, Patrick; Duval, Jérôme F L
2015-01-20
Bioavailability of trace metals is a key parameter for assessment of toxicity on living organisms. Proper evaluation of metal bioavailability requires monitoring the various interfacial processes that control metal partitioning dynamics at the biointerface, which includes metal transport from solution to cell membrane, adsorption at the biosurface, internalization, and possible excretion. In this work, a methodology is proposed to quantitatively describe the dynamics of Cd(II) uptake by Pseudomonas putida. The analysis is based on the kinetic measurement of Cd(II) depletion from bulk solution at various initial cell concentrations using electroanalytical probes. On the basis of a recent formalism on the dynamics of metal uptake by complex biointerphases, the cell concentration-dependent depletion time scales and plateau values reached by metal concentrations at long exposure times (>3 h) are successfully rationalized in terms of limiting metal uptake flux, rate of excretion, and metal affinity to internalization sites. The analysis shows the limits of approximate depletion models valid in the extremes of high and weak metal affinities. The contribution of conductive diffusion transfer of metals from the solution to the cell membrane in governing the rate of Cd(II) uptake is further discussed on the basis of estimated resistances for metal membrane transfer and extracellular mass transport.
Recent advances in vacuum sciences and applications
NASA Astrophysics Data System (ADS)
Mozetič, M.; Ostrikov, K.; Ruzic, D. N.; Curreli, D.; Cvelbar, U.; Vesel, A.; Primc, G.; Leisch, M.; Jousten, K.; Malyshev, O. B.; Hendricks, J. H.; Kövér, L.; Tagliaferro, A.; Conde, O.; Silvestre, A. J.; Giapintzakis, J.; Buljan, M.; Radić, N.; Dražić, G.; Bernstorff, S.; Biederman, H.; Kylián, O.; Hanuš, J.; Miloševič, S.; Galtayries, A.; Dietrich, P.; Unger, W.; Lehocky, M.; Sedlarik, V.; Stana-Kleinschek, K.; Drmota-Petrič, A.; Pireaux, J. J.; Rogers, J. W.; Anderle, M.
2014-04-01
Recent advances in vacuum sciences and applications are reviewed. Novel optical interferometer cavity devices enable pressure measurements with ppm accuracy. The innovative dynamic vacuum standard allows for pressure measurements with temporal resolution of 2 ms. Vacuum issues in the construction of huge ultra-high vacuum devices worldwide are reviewed. Recent advances in surface science and thin films include new phenomena observed in electron transport near solid surfaces as well as novel results on the properties of carbon nanomaterials. Precise techniques for surface and thin-film characterization have been applied in the conservation technology of cultural heritage objects and recent advances in the characterization of biointerfaces are presented. The combination of various vacuum and atmospheric-pressure techniques enables an insight into the complex phenomena of protein and other biomolecule conformations on solid surfaces. Studying these phenomena at solid-liquid interfaces is regarded as the main issue in the development of alternative techniques for drug delivery, tissue engineering and thus the development of innovative techniques for curing cancer and cardiovascular diseases. A review on recent advances in plasma medicine is presented as well as novel hypotheses on cell apoptosis upon treatment with gaseous plasma. Finally, recent advances in plasma nanoscience are illustrated with several examples and a roadmap for future activities is presented.
Crisman, Thomas J; Jenkins, Jeremy L; Parker, Christian N; Hill, W Adam G; Bender, Andreas; Deng, Zhan; Nettles, James H; Davies, John W; Glick, Meir
2007-04-01
This work describes a novel semi-sequential technique for in silico enhancement of high-throughput screening (HTS) experiments now employed at Novartis. It is used in situations in which the size of the screen is limited by the readout (e.g., high-content screens) or the amount of reagents or tools (proteins or cells) available. By performing computational chemical diversity selection on a per plate basis (instead of a per compound basis), 25% of the 1,000,000-compound screening was optimized for general initial HTS. Statistical models are then generated from target-specific primary results (percentage inhibition data) to drive the cherry picking and testing from the entire collection. Using retrospective analysis of 11 HTS campaigns, the authors show that this method would have captured on average two thirds of the active compounds (IC(50) < 10 microM) and three fourths of the active Murcko scaffolds while decreasing screening expenditure by nearly 75%. This result is true for a wide variety of targets, including G-protein-coupled receptors, chemokine receptors, kinases, metalloproteinases, pathway screens, and protein-protein interactions. Unlike time-consuming "classic" sequential approaches that require multiple iterations of cherry picking, testing, and building statistical models, here individual compounds are cherry picked just once, based directly on primary screening data. Strikingly, the authors demonstrate that models built from primary data are as robust as models built from IC(50) data. This is true for all HTS campaigns analyzed, which represent a wide variety of target classes and assay types.
Multi-point objective-oriented sequential sampling strategy for constrained robust design
NASA Astrophysics Data System (ADS)
Zhu, Ping; Zhang, Siliang; Chen, Wei
2015-03-01
Metamodelling techniques are widely used to approximate system responses of expensive simulation models. In association with the use of metamodels, objective-oriented sequential sampling methods have been demonstrated to be effective in balancing the need for searching an optimal solution versus reducing the metamodelling uncertainty. However, existing infilling criteria are developed for deterministic problems and restricted to one sampling point in one iteration. To exploit the use of multiple samples and identify the true robust solution in fewer iterations, a multi-point objective-oriented sequential sampling strategy is proposed for constrained robust design problems. In this article, earlier development of objective-oriented sequential sampling strategy for unconstrained robust design is first extended to constrained problems. Next, a double-loop multi-point sequential sampling strategy is developed. The proposed methods are validated using two mathematical examples followed by a highly nonlinear automotive crashworthiness design example. The results show that the proposed method can mitigate the effect of both metamodelling uncertainty and design uncertainty, and identify the robust design solution more efficiently than the single-point sequential sampling approach.
2014-01-01
Background Pattern recognition (PR) based strategies for the control of myoelectric upper limb prostheses are generally evaluated through offline classification accuracy, which is an admittedly useful metric, but insufficient to discuss functional performance in real time. Existing functional tests are extensive to set up and most fail to provide a challenging, objective framework to assess the strategy performance in real time. Methods Nine able-bodied and two amputee subjects gave informed consent and participated in the local Institutional Review Board approved study. We designed a two-dimensional target acquisition task, based on the principles of Fitts’ law for human motor control. Subjects were prompted to steer a cursor from the screen center of into a series of subsequently appearing targets of different difficulties. Three cursor control systems were tested, corresponding to three electromyography-based prosthetic control strategies: 1) amplitude-based direct control (the clinical standard of care), 2) sequential PR control, and 3) simultaneous PR control, allowing for a concurrent activation of two degrees of freedom (DOF). We computed throughput (bits/second), path efficiency (%), reaction time (second), and overshoot (%)) and used general linear models to assess significant differences between the strategies for each metric. Results We validated the proposed methodology by achieving very high coefficients of determination for Fitts’ law. Both PR strategies significantly outperformed direct control in two-DOF targets and were more intuitive to operate. In one-DOF targets, the simultaneous approach was the least precise. The direct control was efficient in one-DOF targets but cumbersome to operate in two-DOF targets through a switch-depended sequential cursor control. Conclusions We designed a test, capable of comprehensively describing prosthetic control strategies in real time. When implemented on control subjects, the test was able to capture statistically significant differences (p < 0.05) in control strategies when considering throughputs, path efficiencies and reaction times. Of particular note, we found statistically significant (p < 0.01) improvements in throughputs and path efficiencies with simultaneous PR when compared to direct control or sequential PR. Amputees could readily achieve the task; however a limited number of subjects was tested and a statistical analysis was not performed with that population. PMID:24886664
Wurth, Sophie M; Hargrove, Levi J
2014-05-30
Pattern recognition (PR) based strategies for the control of myoelectric upper limb prostheses are generally evaluated through offline classification accuracy, which is an admittedly useful metric, but insufficient to discuss functional performance in real time. Existing functional tests are extensive to set up and most fail to provide a challenging, objective framework to assess the strategy performance in real time. Nine able-bodied and two amputee subjects gave informed consent and participated in the local Institutional Review Board approved study. We designed a two-dimensional target acquisition task, based on the principles of Fitts' law for human motor control. Subjects were prompted to steer a cursor from the screen center of into a series of subsequently appearing targets of different difficulties. Three cursor control systems were tested, corresponding to three electromyography-based prosthetic control strategies: 1) amplitude-based direct control (the clinical standard of care), 2) sequential PR control, and 3) simultaneous PR control, allowing for a concurrent activation of two degrees of freedom (DOF). We computed throughput (bits/second), path efficiency (%), reaction time (second), and overshoot (%)) and used general linear models to assess significant differences between the strategies for each metric. We validated the proposed methodology by achieving very high coefficients of determination for Fitts' law. Both PR strategies significantly outperformed direct control in two-DOF targets and were more intuitive to operate. In one-DOF targets, the simultaneous approach was the least precise. The direct control was efficient in one-DOF targets but cumbersome to operate in two-DOF targets through a switch-depended sequential cursor control. We designed a test, capable of comprehensively describing prosthetic control strategies in real time. When implemented on control subjects, the test was able to capture statistically significant differences (p < 0.05) in control strategies when considering throughputs, path efficiencies and reaction times. Of particular note, we found statistically significant (p < 0.01) improvements in throughputs and path efficiencies with simultaneous PR when compared to direct control or sequential PR. Amputees could readily achieve the task; however a limited number of subjects was tested and a statistical analysis was not performed with that population.
Veiga, Helena Perrut; Bianchini, Esther Mandelbaum Gonçalves
2012-01-01
To perform an integrative review of studies on liquid sequential swallowing, by characterizing the methodology of the studies and the most important findings in young and elderly adults. Review of the literature written in English and Portuguese on PubMed, LILACS, SciELO and MEDLINE databases, within the past twenty years, available fully, using the following uniterms: sequential swallowing, swallowing, dysphagia, cup, straw, in various combinations. Research articles with a methodological approach on the characterization of liquid sequential swallowing by young and/or elderly adults, regardless of health condition, excluding studies involving only the esophageal phase. The following research indicators were applied: objectives, number and gender of participants; age group; amount of liquid offered; intake instruction; utensil used, methods and main findings. 18 studies met the established criteria. The articles were categorized according to the sample characterization and the methodology on volume intake, utensil used and types of exams. Most studies investigated only healthy individuals, with no swallowing complaints. Subjects were given different instructions as to the intake of all the volume: usual manner, continually, as rapidly as possible. The findings about the characterization of sequential swallowing were varied and described in accordance with the objectives of each study. It found great variability in the methodology employed to characterize the sequential swallowing. Some findings are not comparable, and sequential swallowing is not studied in most swallowing protocols, without consensus on the influence of the utensil.
[Bilateral cochlear implants in children: acquisition of binaural hearing].
Ramos-Macías, Angel; Deive-Maggiolo, Leopoldo; Artiles-Cabrera, Ovidio; González-Aguado, Rocío; Borkoski-Barreiro, Silvia A; Masgoret-Palau, Elizabeth; Falcón-González, Juan C; Bueno-Yanes, Jorge
2013-01-01
Several studies have indicated the benefit of bilateral cochlear implants in the acquisition of binaural hearing and bilateralism. In children with cochlear implants, is it possible to achieve binaurality after a second implant? When is the ideal time to implant them? The objective of this study was to analyse the binaural effect in children with bilateral implants and the differences between subjects with simultaneous and sequential implants with both short and long intervals. There were 90 patients between 1 and 2 years of age (the first surgery), implanted between 2000 and 2008. Of these, 25 were unilateral users and 65 bilateral; 17 patients had received simultaneous implants, 29 had sequential implants before 12 months after the first one (short interimplant period) and 19 after 12 months (long period). All of them were tested for silent and noisy verbal perception and a tonal threshold audiometry was performed. The silent perception test showed that the simultaneous and short period sequential implant patients (mean: 84.67%) versus unilateral and long period sequential implants (mean: 79.66%), had a statistically-significant difference (P=0,23). Likewise, the noisy perception test showed a difference with statistical significance (P=0,22) comparing the simultaneous implanted and short period sequential implants (mean, 77.17%) versus unilateral implanted and long period sequential ones (mean: 69.32%). The simultaneous and sequential short period implants acquired the advantages of binaural hearing. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Li, Xinle; Zhang, Biying; Fang, Yuhui; ...
2017-02-11
Here, the facile pyrolysis of a bipyridyl metal-organic framework, MOF-253, produces N-doped porous carbons (Cz-MOF-253), which exhibit excellent catalytic activity in the Knoevenagel condensation reaction and outperform other nitrogen-containing MOF-derived carbons. More importantly, by virtue of their high Lewis basicity and porous nature, Cz-MOF-253-supported Pd nanoparticles (Pd/Cz-MOF-253-800) show excellent performance in a one-pot sequential Knoevenagel condensation-hydrogenation reaction.
Formation of Onion-Like NiCo2 S4 Particles via Sequential Ion-Exchange for Hybrid Supercapacitors.
Guan, Bu Yuan; Yu, Le; Wang, Xiao; Song, Shuyan; Lou, Xiong Wen David
2017-02-01
Onion-like NiCo 2 S 4 particles with unique hollow structured shells are synthesized by a sequential ion-exchange strategy. With the structural and compositional advantages, these unique onion-like NiCo 2 S 4 particles exhibit enhanced electrochemical performance as an electrode material for hybrid supercapacitors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Brief Lags in Interrupted Sequential Performance: Evaluating a Model and Model Evaluation Method
2015-01-05
rehearsal mechanism in the model. To evaluate the model we developed a simple new goodness-of-fit test based on analysis of variance that offers an...repeated step). Sequen- tial constraints are common in medicine, equipment maintenance, computer programming and technical support, data analysis ...legal analysis , accounting, and many other home and workplace environ- ments. Sequential constraints also play a role in such basic cognitive processes
2014-01-01
Background End-to-side anastomoses to connect the distal end of the great saphenous vein (GSV) to small target coronary arteries are commonly performed in sequential coronary artery bypass grafting (CABG). However, the oversize diameter ratio between the GSV and small target vessels at end-to-side anastomoses might induce adverse hemodynamic condition. The purpose of this study was to describe a distal end side-to-side anastomosis technique and retrospectively compare the effect of distal end side-to-side versus end-to-side anastomosis on graft flow characteristics. Methods We performed side-to-side anastomoses to connect the distal end of the GSV to small target vessels on 30 patients undergoing off-pump sequential CABG in our hospital between October 2012 and July 2013. Among the 30 patients, end-to-side anastomoses at the distal end of the GSV were initially performed on 14 patients; however, due to poor graft flow, those anastomoses were revised into side-to-side anastomoses. We retrospectively compared the intraoperative graft flow characteristics of the end-to-side versus side-to-side anastomoses in the 14 patients. The patient outcomes were also evaluated. Results We found that the side-to-side anastomosis reconstruction improved intraoperative flow and reduced pulsatility index in all the 14 patients significantly. The 16 patients who had the distal end side-to-side anastomoses performed directly also exhibited satisfactory intraoperative graft flow. Three-month postoperative outcomes for all the patients were satisfactory. Conclusions Side-to-side anastomosis at the distal end of sequential vein grafts might be a promising strategy to connect small target coronary arteries to the GSV. PMID:24884776
Kibby, Michelle Y.; Dyer, Sarah M.; Vadnais, Sarah A.; Jagger, Audreyana C.; Casher, Gabriel A.; Stacy, Maria
2015-01-01
Whether visual processing deficits are common in reading disorders (RD), and related to reading ability in general, has been debated for decades. The type of visual processing affected also is debated, although visual discrimination and short-term memory (STM) may be more commonly related to reading ability. Reading disorders are frequently comorbid with ADHD, and children with ADHD often have subclinical reading problems. Hence, children with ADHD were used as a comparison group in this study. ADHD and RD may be dissociated in terms of visual processing. Whereas RD may be associated with deficits in visual discrimination and STM for order, ADHD is associated with deficits in visual-spatial processing. Thus, we hypothesized that children with RD would perform worse than controls and children with ADHD only on a measure of visual discrimination and a measure of visual STM that requires memory for order. We expected all groups would perform comparably on the measure of visual STM that does not require sequential processing. We found children with RD or ADHD were commensurate to controls on measures of visual discrimination and visual STM that do not require sequential processing. In contrast, both RD groups (RD, RD/ADHD) performed worse than controls on the measure of visual STM that requires memory for order, and children with comorbid RD/ADHD performed worse than those with ADHD. In addition, of the three visual measures, only sequential visual STM predicted reading ability. Hence, our findings suggest there is a deficit in visual sequential STM that is specific to RD and is related to basic reading ability. The source of this deficit is worthy of further research, but it may include both reduced memory for order and poorer verbal mediation. PMID:26579020
Kibby, Michelle Y; Dyer, Sarah M; Vadnais, Sarah A; Jagger, Audreyana C; Casher, Gabriel A; Stacy, Maria
2015-01-01
Whether visual processing deficits are common in reading disorders (RD), and related to reading ability in general, has been debated for decades. The type of visual processing affected also is debated, although visual discrimination and short-term memory (STM) may be more commonly related to reading ability. Reading disorders are frequently comorbid with ADHD, and children with ADHD often have subclinical reading problems. Hence, children with ADHD were used as a comparison group in this study. ADHD and RD may be dissociated in terms of visual processing. Whereas RD may be associated with deficits in visual discrimination and STM for order, ADHD is associated with deficits in visual-spatial processing. Thus, we hypothesized that children with RD would perform worse than controls and children with ADHD only on a measure of visual discrimination and a measure of visual STM that requires memory for order. We expected all groups would perform comparably on the measure of visual STM that does not require sequential processing. We found children with RD or ADHD were commensurate to controls on measures of visual discrimination and visual STM that do not require sequential processing. In contrast, both RD groups (RD, RD/ADHD) performed worse than controls on the measure of visual STM that requires memory for order, and children with comorbid RD/ADHD performed worse than those with ADHD. In addition, of the three visual measures, only sequential visual STM predicted reading ability. Hence, our findings suggest there is a deficit in visual sequential STM that is specific to RD and is related to basic reading ability. The source of this deficit is worthy of further research, but it may include both reduced memory for order and poorer verbal mediation.
NASA Astrophysics Data System (ADS)
Masson, F.; Mouyen, M.; Hwang, C.; Wu, Y.-M.; Ponton, F.; Lehujeur, M.; Dorbath, C.
2012-11-01
Using a Bouguer anomaly map and a dense seismic data set, we have performed two studies in order to improve our knowledge of the deep structure of Taiwan. First, we model the Bouguer anomaly along a profile crossing the island using simple forward modelling. The modelling is 2D, with the hypothesis of cylindrical symmetry. Second we present a joint analysis of gravity anomaly and seismic arrival time data recorded in Taiwan. An initial velocity model has been obtained by local earthquake tomography (LET) of the seismological data. The LET velocity model was used to construct an initial 3D gravity model, using a linear velocity-density relationship (Birch's law). The synthetic Bouguer anomaly calculated for this model has the same shape and wavelength as the observed anomaly. However some characteristics of the anomaly map are not retrieved. To derive a crustal velocity/density model which accounts for both types of observations, we performed a sequential inversion of seismological and gravity data. The variance reduction of the arrival time data for the final sequential model was comparable to the variance reduction obtained by simple LET. Moreover, the sequential model explained about 80% of the observed gravity anomaly. New 3D model of Taiwan lithosphere is presented.
Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods
NASA Technical Reports Server (NTRS)
Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.
1991-01-01
The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.
Hinault, Thomas; Lemaire, Patrick; Touron, Dayna
2017-02-01
In this study, we asked young adults and older adults to encode pairs of words. For each item, they were told which strategy to use, interactive imagery or rote repetition. Data revealed poorer-strategy effects in both young adults and older adults: Participants obtained better performance when executing better strategies (i.e., interactive-imagery strategy to encode pairs of concrete words; rote-repetition strategy on pairs of abstract words) than with poorer strategies (i.e., interactive-imagery strategy on pairs of abstract words; rote-repetition strategy on pairs of concrete words). Crucially, we showed that sequential modulations of poorer-strategy effects (i.e., poorer-strategy effects being larger when previous items were encoded with better relative to poorer strategies), previously demonstrated in arithmetic, generalise to memory strategies. We also found reduced sequential modulations of poorer-strategy effects in older adults relative to young adults. Finally, sequential modulations of poorer-strategy effects correlated with measures of cognitive control processes, suggesting that these processes underlie efficient trial-to-trial modulations during strategy execution. Differences in correlations with cognitive control processes were also found between older adults and young adults. These findings have important implications regarding mechanisms underlying memory strategy execution and age differences in memory performance.
Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods
NASA Astrophysics Data System (ADS)
Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.
1991-10-01
The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.
Episodic Contributions to Sequential Control: Learning from a Typist's Touch
ERIC Educational Resources Information Center
Crump, Matthew J. C.; Logan, Gordon D.
2010-01-01
Sequential control over routine action is widely assumed to be controlled by stable, highly practiced representations. Our findings demonstrate that the processes controlling routine actions in the domain of skilled typing can be flexibly manipulated by memory processes coding recent experience with typing particular words and letters. In two…
Fang, Yuyu; Li, Caixia; Wu, Lei; Bai, Bing; Li, Xing; Jia, Yiming; Feng, Wen; Yuan, Lihua
2015-09-07
A novel non-symmetric pillar[5]arene bearing triazole-linked 8-oxyquinolines at one rim was synthesized and demonstrated as a sequential fluorescence sensor for thorium(iv) followed by fluoride ions with high sensitivity and selectivity.
Hack, Daniel; Chauhan, Pankaj; Deckers, Kristina; Mizutani, Yusuke; Raabe, Gerhard; Enders, Dieter
2015-02-11
A one-pot asymmetric Michael addition/hydroalkoxylation sequence, catalyzed by a sequential catalytic system consisting of a squaramide and a silver salt, provides a new series of chiral pyrano-annulated pyrazole derivatives in excellent yields (up to 95%) and high enantioselectivities (up to 97% ee).
Failure detection system design methodology. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Chow, E. Y.
1980-01-01
The design of a failure detection and identification system consists of designing a robust residual generation process and a high performance decision making process. The design of these two processes are examined separately. Residual generation is based on analytical redundancy. Redundancy relations that are insensitive to modelling errors and noise effects are important for designing robust residual generation processes. The characterization of the concept of analytical redundancy in terms of a generalized parity space provides a framework in which a systematic approach to the determination of robust redundancy relations are developed. The Bayesian approach is adopted for the design of high performance decision processes. The FDI decision problem is formulated as a Bayes sequential decision problem. Since the optimal decision rule is incomputable, a methodology for designing suboptimal rules is proposed. A numerical algorithm is developed to facilitate the design and performance evaluation of suboptimal rules.
Fractionation of (137)Cs and Pu in natural peatland.
Mihalík, Ján; Bartusková, Miluše; Hölgye, Zoltán; Ježková, Tereza; Henych, Ondřej
2014-08-01
High Cs-137 concentrations in plants growing on peatland inspired us to investigate the quantity of its bioavailable fraction in natural peat. Our investigation aims to: a) estimate the quantity of bioavailable Cs-137 and Pu present in peat, b) verify the similarity of Cs-137 and K-40 behaviours, and c) perform a quantification of Cs-137 and Pu transfer from peat to plants. We analysed the vertical distribution of Cs-137 and Pu isotopes in the peat and their concentrations in plants growing on these places. Bioavailability of radionuclides was investigated by sequential extraction. Sequential analyses revealed that it was the upper layer which contained the majority of Cs-137 in an available form while deeper layers retained Cs-137 in immobile fractions. We can conclude that 18% of all Cs-137 in the peat is still bioavailable. Despite of the low quantity of bioavailable fraction of Cs-137 its transfer factor reached extremely high values. In the case of Pu, 64% of its total amount was associated with fulvic/humic acids which resulted in the high transfer factor from peat to plants. 27 years after the Chernobyl nuclear accident, the significant part of radionuclides deposited in peatland is still bioavailable. Copyright © 2014 Elsevier Ltd. All rights reserved.
Performance evaluation of an asynchronous multisensor track fusion filter
NASA Astrophysics Data System (ADS)
Alouani, Ali T.; Gray, John E.; McCabe, D. H.
2003-08-01
Recently the authors developed a new filter that uses data generated by asynchronous sensors to produce a state estimate that is optimal in the minimum mean square sense. The solution accounts for communications delay between sensors platform and fusion center. It also deals with out of sequence data as well as latent data by processing the information in a batch-like manner. This paper compares, using simulated targets and Monte Carlo simulations, the performance of the filter to the optimal sequential processing approach. It was found that the new asynchronous Multisensor track fusion filter (AMSTFF) performance is identical to that of the extended sequential Kalman filter (SEKF), while the new filter updates its track at a much lower rate than the SEKF.
Xu, Yan; Wu, Qian; Shimatani, Yuji; Yamaguchi, Koji
2015-10-07
Due to the lack of regeneration methods, the reusability of nanofluidic chips is a significant technical challenge impeding the efficient and economic promotion of both fundamental research and practical applications on nanofluidics. Herein, a simple method for the total regeneration of glass nanofluidic chips was described. The method consists of sequential thermal treatment with six well-designed steps, which correspond to four sequential thermal and thermochemical decomposition processes, namely, dehydration, high-temperature redox chemical reaction, high-temperature gasification, and cooling. The method enabled the total regeneration of typical 'dead' glass nanofluidic chips by eliminating physically clogged nanoparticles in the nanochannels, removing chemically reacted organic matter on the glass surface and regenerating permanent functional surfaces of dissimilar materials localized in the nanochannels. The method provides a technical solution to significantly improve the reusability of glass nanofluidic chips and will be useful for the promotion and acceleration of research and applications on nanofluidics.
Resisting distraction and response inhibition trigger similar enhancements of future performance.
Bissett, Patrick G; Grant, Lauren D; Weissman, Daniel H
2017-10-01
Resisting distraction and response inhibition are crucial aspects of cognitive control. Interestingly, each of these abilities transiently improves just after it is utilized. Competing views differ, however, as to whether utilizing either of these abilities (e.g., resisting distraction) enhances future performance involving the other ability (e.g., response inhibition). To distinguish between these views, we combined a Stroop-like task that requires resisting distraction with a restraint variant of the stop-signal task that requires response inhibition. We observed similar sequential-trial effects (i.e., performance enhancements) following trials in which participants (a) resisted distraction (i.e., incongruent go trials) and (b) inhibited a response (i.e., congruent stop trials). First, the congruency effect in go trials, which indexes overall distractibility, was smaller after both incongruent go trials and congruent stop trials than it was after congruent go trials. Second, stop failures were less frequent after both incongruent go trials and congruent stop trials than after congruent go trials. A control experiment ruled out the possibility that perceptual conflict or surprise engendered by occasional stop signals triggers sequential-trial effects independent of stopping. Thus, our findings support a novel, integrated view in which resisting distraction and response inhibition trigger similar sequential enhancements of future performance. Copyright © 2017 Elsevier B.V. All rights reserved.
The impact of fillers on lineup performance.
Wetmore, Stacy A; McAdoo, Ryan M; Gronlund, Scott D; Neuschatz, Jeffrey S
2017-01-01
Filler siphoning theory posits that the presence of fillers (known innocents) in a lineup protects an innocent suspect from being chosen by siphoning choices away from that innocent suspect. This mechanism has been proposed as an explanation for why simultaneous lineups (viewing all lineup members at once) induces better performance than showups (one-person identification procedures). We implemented filler siphoning in a computational model (WITNESS, Clark, Applied Cognitive Psychology 17:629-654, 2003), and explored the impact of the number of fillers (lineup size) and filler quality on simultaneous and sequential lineups (viewing lineups members in sequence), and compared both to showups. In limited situations, we found that filler siphoning can produce a simultaneous lineup performance advantage, but one that is insufficient in magnitude to explain empirical data. However, the magnitude of the empirical simultaneous lineup advantage can be approximated once criterial variability is added to the model. But this modification works by negatively impacting showups rather than promoting more filler siphoning. In sequential lineups, fillers were found to harm performance. Filler siphoning fails to clarify the relationship between simultaneous lineups and sequential lineups or showups. By incorporating constructs like filler siphoning and criterial variability into a computational model, and trying to approximate empirical data, we can sort through explanations of eyewitness decision-making, a prerequisite for policy recommendations.
Performance Analysis of Ranging Techniques for the KPLO Mission
NASA Astrophysics Data System (ADS)
Park, Sungjoon; Moon, Sangman
2018-03-01
In this study, the performance of ranging techniques for the Korea Pathfinder Lunar Orbiter (KPLO) space communication system is investigated. KPLO is the first lunar mission of Korea, and pseudo-noise (PN) ranging will be used to support the mission along with sequential ranging. We compared the performance of both ranging techniques using the criteria of accuracy, acquisition probability, and measurement time. First, we investigated the end-to-end accuracy error of a ranging technique incorporating all sources of errors such as from ground stations and the spacecraft communication system. This study demonstrates that increasing the clock frequency of the ranging system is not required when the dominant factor of accuracy error is independent of the thermal noise of the ranging technique being used in the system. Based on the understanding of ranging accuracy, the measurement time of PN and sequential ranging are further investigated and compared, while both techniques satisfied the accuracy and acquisition requirements. We demonstrated that PN ranging performed better than sequential ranging in the signal-to-noise ratio (SNR) regime where KPLO will be operating, and we found that the T2B (weighted-voting balanced Tausworthe, voting v = 2) code is the best choice among the PN codes available for the KPLO mission.
A Bayesian Theory of Sequential Causal Learning and Abstract Transfer.
Lu, Hongjing; Rojas, Randall R; Beckers, Tom; Yuille, Alan L
2016-03-01
Two key research issues in the field of causal learning are how people acquire causal knowledge when observing data that are presented sequentially, and the level of abstraction at which learning takes place. Does sequential causal learning solely involve the acquisition of specific cause-effect links, or do learners also acquire knowledge about abstract causal constraints? Recent empirical studies have revealed that experience with one set of causal cues can dramatically alter subsequent learning and performance with entirely different cues, suggesting that learning involves abstract transfer, and such transfer effects involve sequential presentation of distinct sets of causal cues. It has been demonstrated that pre-training (or even post-training) can modulate classic causal learning phenomena such as forward and backward blocking. To account for these effects, we propose a Bayesian theory of sequential causal learning. The theory assumes that humans are able to consider and use several alternative causal generative models, each instantiating a different causal integration rule. Model selection is used to decide which integration rule to use in a given learning environment in order to infer causal knowledge from sequential data. Detailed computer simulations demonstrate that humans rely on the abstract characteristics of outcome variables (e.g., binary vs. continuous) to select a causal integration rule, which in turn alters causal learning in a variety of blocking and overshadowing paradigms. When the nature of the outcome variable is ambiguous, humans select the model that yields the best fit with the recent environment, and then apply it to subsequent learning tasks. Based on sequential patterns of cue-outcome co-occurrence, the theory can account for a range of phenomena in sequential causal learning, including various blocking effects, primacy effects in some experimental conditions, and apparently abstract transfer of causal knowledge. Copyright © 2015 Cognitive Science Society, Inc.
Reductionist Approach in Peptide-Based Nanotechnology.
Gazit, Ehud
2018-06-20
The formation of ordered nanostructures by molecular self-assembly of proteins and peptides represents one of the principal directions in nanotechnology. Indeed, polyamides provide superior features as materials with diverse physical properties. A reductionist approach allowed the identification of extremely short peptide sequences, as short as dipeptides, which could form well-ordered amyloid-like β-sheet-rich assemblies comparable to supramolecular structures made of much larger proteins. Some of the peptide assemblies show remarkable mechanical, optical, and electrical characteristics. Another direction of reductionism utilized a natural noncoded amino acid, α-aminoisobutryic acid, to form short superhelical assemblies. The use of this exceptional helix inducer motif allowed the fabrication of single heptad repeats used in various biointerfaces, including their use as surfactants and DNA-binding agents. Two additional directions of the reductionist approach include the use of peptide nucleic acids (PNAs) and coassembly techniques. The diversified accomplishments of the reductionist approach, as well as the exciting future advances it bears, are discussed.
Biomaterials-Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, Meredith; Bettinger, Christopher J.
2012-01-01
Advanced polymeric biomaterials continue to serve as a cornerstone of new medical technologies and therapies. The vast majority of these materials, both natural and synthetic, interact with biological matter without direct electronic communication. However, biological systems have evolved to synthesize and employ naturally-derived materials for the generation and modulation of electrical potentials, voltage gradients, and ion flows. Bioelectric phenomena can be interpreted as potent signaling cues for intra- and inter-cellular communication. These cues can serve as a gateway to link synthetic devices with biological systems. This progress report will provide an update on advances in the application of electronically active biomaterials for use in organic electronics and bio-interfaces. Specific focus will be granted to the use of natural and synthetic biological materials as integral components in technologies such as thin film electronics, in vitro cell culture models, and implantable medical devices. Future perspectives and emerging challenges will also be highlighted. PMID:23184740
Electrical manipulation of oligonucleotides grafted to charged surfaces.
Rant, Ulrich; Arinaga, Kenji; Fujita, Shozo; Yokoyama, Naoki; Abstreiter, Gerhard; Tornow, Marc
2006-09-21
The electrical manipulation of short DNA molecules on surfaces offers novel functionalities with fascinating possibilities in the field of bio-interfaces. Here we present systematic investigations of the electrical interactions which govern the structure of oligonucleotides on charged gold surfaces. Successively, we address influences of the applied field strength, the role of DC electrode potentials, in particular for polycrystalline surfaces, as well as screening effects of the surrounding electrolyte solution. Data obtained for single and double stranded DNA exhibit differences which can be attributed to the dissimilar flexibility of the different molecular conformations. A comparison of the experimental results with a basic model shows how the alignment of the molecules adjusts according to a balance between electrically induced ordering and stochastic thermal motions. The presented conclusions are expected to be of general relevance for the behaviour of polyelectrolytes exposed to localized electric fields at interfaces.
NASA Astrophysics Data System (ADS)
Okano, Teruo; Kikuchi, Akihiko
1996-04-01
Considerable research attention has been focused recently on materials which change their structure and properties in response to external stimuli. These materials, termed `intelligent materials', sense a stimulus as a signal (sensor function), judge the magnitude of this signal (processor function), and then alter their function in direct response (effector function). Introduction of stimuli-responsive polymers as switching sequences into both artificial materials and bioactive molecules would permit external, stimuli-induced modulation of their structures and `on-off' switching of their respective functions at molecular levels. Intelligent materials embodying these concepts would contribute to the establishment of basic principles for fabricating novel systems which modulate their structural changes and functional changes in response to external stimuli. These materials are attractive not only as new, sophisticated biomaterials but also for utilization in protein biotechnology, medical diagnosis and advanced site-specific drug delivery system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaehr, Bryan James
This is the final report for the President Harry S. Truman Fellowship in National Security Science and Engineering (LDRD project 130813) awarded to Dr. Bryan Kaehr from 2008-2011. Biological chemistries, cells, and integrated systems (e.g., organisms, ecologies, etc.) offer important lessons for the design of synthetic strategies and materials. The desire to both understand and ultimately improve upon biological processes has been a driving force for considerable scientific efforts worldwide. However, to impart the useful properties of biological systems into modern devices and materials requires new ideas and technologies. The research herein addresses aspects of these issues through the developmentmore » of (1) a rapid-prototyping methodology to build 3D bio-interfaces and catalytic architectures, (2) a quantitative method to measure cell/material mechanical interactions in situ and at the microscale, and (3) a breakthrough approach to generate functional biocomposites from bacteria and cultured cells.« less
Micropatterned arrays of porous silicon: toward sensory biointerfaces.
Flavel, Benjamin S; Sweetman, Martin J; Shearer, Cameron J; Shapter, Joseph G; Voelcker, Nicolas H
2011-07-01
We describe the fabrication of arrays of porous silicon spots by means of photolithography where a positive photoresist serves as a mask during the anodization process. In particular, photoluminescent arrays and porous silicon spots suitable for further chemical modification and the attachment of human cells were created. The produced arrays of porous silicon were chemically modified by means of a thermal hydrosilylation reaction that facilitated immobilization of the fluorescent dye lissamine, and alternatively, the cell adhesion peptide arginine-glycine-aspartic acid-serine. The latter modification enabled the selective attachment of human lens epithelial cells on the peptide functionalized regions of the patterns. This type of surface patterning, using etched porous silicon arrays functionalized with biological recognition elements, presents a new format of interfacing porous silicon with mammalian cells. Porous silicon arrays with photoluminescent properties produced by this patterning strategy also have potential applications as platforms for in situ monitoring of cell behavior.
The Photo-Physics of Polythiophene Nanoparticles for Biological Applications.
Bargigia, Ilaria; Zucchetti, Elena; Srimath Kandada, Ajay Ram; Moreira, Miguel; Bossio, Caterina; Wong, Walter; Miranda, Paulo; Decuzzi, Paolo; Soci, Cesare; D'Andrea, Cosimo; Lanzani, Guglielmo
2018-05-01
In this work the photo-physics of poly(3-hexyltiophene) nanoparticles (NPs) is investigated in the context of their biological applications. The NPs made as colloidal suspensions in aqueous buffers present a distinct absorption band in the low energy region. Based on systematic analysis of absorption and transient absorption spectra taken under different pH conditions, this band is associated to charge transfer states generated by the polarization of loosely bound polymer chains and originated from complexes formed with electron withdrawing species. Importantly, the ground state depletion of these states upon photo-excitation is active even in the microsecond timescales, suggesting that they act as precursor states for long-living polarons which could be beneficial for cellular stimulation. Preliminary results of transient absorption microscopy of NPs internalized within the cells reveal the presence of long-living species, further substantiating their relevance in bio-interfaces. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ion specific correlations in bulk and at biointerfaces.
Kalcher, I; Horinek, D; Netz, R R; Dzubiella, J
2009-10-21
Ion specific effects are ubiquitous in any complex colloidal or biological fluid in bulk or at interfaces. The molecular origins of these 'Hofmeister effects' are not well understood and their theoretical description poses a formidable challenge to the modeling and simulation community. On the basis of the combination of atomistically resolved molecular dynamics (MD) computer simulations and statistical mechanics approaches, we present a few selected examples of specific electrolyte effects in bulk, at simple neutral and charged interfaces, and on a short α-helical peptide. The structural complexity in these strongly Coulomb-correlated systems is highlighted and analyzed in the light of available experimental data. While in general the comparison of MD simulations to experiments often lacks quantitative agreement, mostly because molecular force fields and coarse-graining procedures remain to be optimized, the consensus as regards trends provides important insights into microscopic hydration and binding mechanisms.
Olusesi, A D; Oyeniran, O
2017-05-01
Few studies have compared bilateral same-day with staged tympanoplasty using cartilage graft materials. A prospective randomised observational study was performed of 38 chronic suppurative otitis media patients (76 ears) who were assigned to undergo bilateral sequential same-day tympanoplasty (18 patients, 36 ears) or bilateral sequential tympanoplasty performed 3 months apart (20 patients, 40 ears). Disease duration, intra-operative findings, combined duration of surgery, post-operative graft appearance at 6 weeks, post-operative complications, re-do rate and relative cost of surgery were recorded. Tympanic membrane perforations were predominantly subtotal (p = 0.36, odds ratio = 0.75). Most grafts were harvested from the conchal cartilage and fewer from the tragus (p = 0.59, odds ratio = 1.016). Types of complication, post-operative hearing gain and revision rates were similar in both patient groups. Surgical outcomes are not significantly different for same-day and bilateral cartilage tympanoplasty, but same-day surgery has the added benefit of a lower cost.
Yu, Zhan; Li, Yuanyang; Liu, Lisheng; Guo, Jin; Wang, Tingfeng; Yang, Guoqing
2017-11-10
The speckle pattern (line by line) sequential extraction (SPSE) metric is proposed by the one-dimensional speckle intensity level crossing theory. Through the sequential extraction of received speckle information, the speckle metrics for estimating the variation of focusing spot size on a remote diffuse target are obtained. Based on the simulation, we will give some discussions about the SPSE metric range of application under the theoretical conditions, and the aperture size will affect the metric performance of the observation system. The results of the analyses are verified by the experiment. This method is applied to the detection of relative static target (speckled jitter frequency is less than the CCD sampling frequency). The SPSE metric can determine the variation of the focusing spot size over a long distance, moreover, the metric will estimate the spot size under some conditions. Therefore, the monitoring and the feedback of far-field spot will be implemented laser focusing system applications and help the system to optimize the focusing performance.
Perceptual Grouping Affects Pitch Judgments Across Time and Frequency
Borchert, Elizabeth M. O.; Micheyl, Christophe; Oxenham, Andrew J.
2010-01-01
Pitch, the perceptual correlate of fundamental frequency (F0), plays an important role in speech, music and animal vocalizations. Changes in F0 over time help define musical melodies and speech prosody, while comparisons of simultaneous F0 are important for musical harmony, and for segregating competing sound sources. This study compared listeners’ ability to detect differences in F0 between pairs of sequential or simultaneous tones that were filtered into separate, non-overlapping spectral regions. The timbre differences induced by filtering led to poor F0 discrimination in the sequential, but not the simultaneous, conditions. Temporal overlap of the two tones was not sufficient to produce good performance; instead performance appeared to depend on the two tones being integrated into the same perceptual object. The results confirm the difficulty of comparing the pitches of sequential sounds with different timbres and suggest that, for simultaneous sounds, pitch differences may be detected through a decrease in perceptual fusion rather than an explicit coding and comparison of the underlying F0s. PMID:21077719
Win-Stay, Lose-Sample: a simple sequential algorithm for approximating Bayesian inference.
Bonawitz, Elizabeth; Denison, Stephanie; Gopnik, Alison; Griffiths, Thomas L
2014-11-01
People can behave in a way that is consistent with Bayesian models of cognition, despite the fact that performing exact Bayesian inference is computationally challenging. What algorithms could people be using to make this possible? We show that a simple sequential algorithm "Win-Stay, Lose-Sample", inspired by the Win-Stay, Lose-Shift (WSLS) principle, can be used to approximate Bayesian inference. We investigate the behavior of adults and preschoolers on two causal learning tasks to test whether people might use a similar algorithm. These studies use a "mini-microgenetic method", investigating how people sequentially update their beliefs as they encounter new evidence. Experiment 1 investigates a deterministic causal learning scenario and Experiments 2 and 3 examine how people make inferences in a stochastic scenario. The behavior of adults and preschoolers in these experiments is consistent with our Bayesian version of the WSLS principle. This algorithm provides both a practical method for performing Bayesian inference and a new way to understand people's judgments. Copyright © 2014 Elsevier Inc. All rights reserved.
NeCamp, Timothy; Kilbourne, Amy; Almirall, Daniel
2017-08-01
Cluster-level dynamic treatment regimens can be used to guide sequential treatment decision-making at the cluster level in order to improve outcomes at the individual or patient-level. In a cluster-level dynamic treatment regimen, the treatment is potentially adapted and re-adapted over time based on changes in the cluster that could be impacted by prior intervention, including aggregate measures of the individuals or patients that compose it. Cluster-randomized sequential multiple assignment randomized trials can be used to answer multiple open questions preventing scientists from developing high-quality cluster-level dynamic treatment regimens. In a cluster-randomized sequential multiple assignment randomized trial, sequential randomizations occur at the cluster level and outcomes are observed at the individual level. This manuscript makes two contributions to the design and analysis of cluster-randomized sequential multiple assignment randomized trials. First, a weighted least squares regression approach is proposed for comparing the mean of a patient-level outcome between the cluster-level dynamic treatment regimens embedded in a sequential multiple assignment randomized trial. The regression approach facilitates the use of baseline covariates which is often critical in the analysis of cluster-level trials. Second, sample size calculators are derived for two common cluster-randomized sequential multiple assignment randomized trial designs for use when the primary aim is a between-dynamic treatment regimen comparison of the mean of a continuous patient-level outcome. The methods are motivated by the Adaptive Implementation of Effective Programs Trial which is, to our knowledge, the first-ever cluster-randomized sequential multiple assignment randomized trial in psychiatry.
NASA Astrophysics Data System (ADS)
Starks, Michael R.
1990-09-01
A variety of low cost devices for capturing, editing and displaying field sequential 60 cycle stereoscopic video have recently been marketed by 3D TV Corp. and others. When properly used, they give very high quality images with most consumer and professional equipment. Our stereoscopic multiplexers for creating and editing field sequential video in NTSC or component(SVHS, Betacain, RGB) and Home 3D Theater system employing LCD eyeglasses have made 3D movies and television available to a large audience.
Beccaria, Marco; Inferrera, Veronica; Rigano, Francesca; Gorynski, Krzysztof; Purcaro, Giorgia; Pawliszyn, Janusz; Dugo, Paola; Mondello, Luigi
2017-08-04
A simple, fast, and versatile method, using an ultra-high performance liquid chromatography system coupled with a low resolution (single quadrupole) mass spectrometer was optimized to perform multiclass lipid profiling of human plasma. Particular attention was made to develop a method suitable for both electrospray ionization and atmospheric pressure chemical ionization interfaces (sequentially in positive- and negative-ion mode), without any modification of the chromatographic conditions (mobile phase, flow-rate, gradient, etc.). Emphasis was given to the extrapolation of the structural information based on the fragmentation pattern obtained using atmospheric pressure chemical ionization interface, under each different ionization condition, highlighting the complementary information obtained using the electrospray ionization interface, of support for related molecule ions identification. Furthermore, mass spectra of phosphatidylserine and phosphatidylinositol obtained using the atmospheric pressure chemical ionization interface are reported and discussed for the first time. Copyright © 2017 Elsevier B.V. All rights reserved.
Ezoe, Kentaro; Ohyama, Seiichi; Hashem, Md Abul; Ohira, Shin-Ichi; Toda, Kei
2016-02-01
After the Fukushima disaster, power generation from nuclear power plants in Japan was completely stopped and old coal-based power plants were re-commissioned to compensate for the decrease in power generation capacity. Although coal is a relatively inexpensive fuel for power generation, it contains high levels (mgkg(-1)) of selenium, which could contaminate the wastewater from thermal power plants. In this work, an automated selenium monitoring system was developed based on sequential hydride generation and chemiluminescence detection. This method could be applied to control of wastewater contamination. In this method, selenium is vaporized as H2Se, which reacts with ozone to produce chemiluminescence. However, interference from arsenic is of concern because the ozone-induced chemiluminescence intensity of H2Se is much lower than that of AsH3. This problem was successfully addressed by vaporizing arsenic and selenium individually in a sequential procedure using a syringe pump equipped with an eight-port selection valve and hot and cold reactors. Oxidative decomposition of organoselenium compounds and pre-reduction of the selenium were performed in the hot reactor, and vapor generation of arsenic and selenium were performed separately in the cold reactor. Sample transfers between the reactors were carried out by a pneumatic air operation by switching with three-way solenoid valves. The detection limit for selenium was 0.008 mg L(-1) and calibration curve was linear up to 1.0 mg L(-1), which provided suitable performance for controlling selenium in wastewater to around the allowable limit (0.1 mg L(-1)). This system consumes few chemicals and is stable for more than a month without any maintenance. Wastewater samples from thermal power plants were collected, and data obtained by the proposed method were compared with those from batchwise water treatment followed by hydride generation-atomic fluorescence spectrometry. Copyright © 2015 Elsevier B.V. All rights reserved.
Ziylan-Yavas, Asu; Ince, Nilsun H
2018-01-01
The study is about the assessment of single and multi-frequency operations for the overall degradation of a widely consumed analgesic pharmaceutical-ibuprofen (IBP). The selected frequencies were in the range of 20-1130kHz emissions coming from probes, baths and piezo-electric transducers attached to plate-type devices. Multi-frequency operations were applied either simultaneously as "duals", or sequentially at fixed time intervals; and the total reaction time in all operations was 30-min. The work also covers evaluation of the effect of zero-valent iron (ZVI) on the efficiency of the degradation process and the performance of the reaction systems. It was found that low-frequency probe type devices especially at 20kHz were ineffective when applied singly and without ZVI, and relatively more effective in combined-frequency operations in the presence of ZVI. The power efficiencies of the reactors and/or reaction systems showed that 20-kHz probe was considerably more energy intensive than all others, and was therefore not used in multi-frequency operations. The most efficient reactor in terms of power consumption was the bath (200kHz), which however provided insufficient mineralization of the test chemical. The highest percentage of TOC decay (37%) was obtained in a dual-frequency operation (40/572kHz) with ZVI, in which the energy consumption was neither low nor exceptionally too high. A sequential operation (40+200kHz) in that respect was more efficient, because it required much less energy for a similar TOC decay performance (30%). In general, the degradation of IBP increased with increased power consumption, which in turn reduced the sonochemical yield. The study also showed that advanced Fenton reactions with ZVI were faster in the presence of ultrasound, and the metal was very effective in improving the performance of low-frequency operations. Copyright © 2017 Elsevier B.V. All rights reserved.
Gobert, Antoine; Tourdot-Maréchal, Raphaëlle; Morge, Christophe; Sparrow, Céline; Liu, Youzhong; Quintanilla-Casas, Beatriz; Vichi, Stefania; Alexandre, Hervé
2017-01-01
Nitrogen sources in the must are important for yeast metabolism, growth, and performance, and wine volatile compounds profile. Yeast assimilable nitrogen (YAN) deficiencies in grape must are one of the main causes of stuck and sluggish fermentation. The nitrogen requirement of Saccharomyces cerevisiae metabolism has been described in detail. However, the YAN preferences of non-Saccharomyces yeasts remain unknown despite their increasingly widespread use in winemaking. Furthermore, the impact of nitrogen consumption by non-Saccharomyces yeasts on YAN availability, alcoholic performance and volatile compounds production by S. cerevisiae in sequential fermentation has been little studied. With a view to improving the use of non-Saccharomyces yeasts in winemaking, we studied the use of amino acids and ammonium by three strains of non-Saccharomyces yeasts (Starmerella bacillaris, Metschnikowia pulcherrima, and Pichia membranifaciens) in grape juice. We first determined which nitrogen sources were preferentially used by these yeasts in pure cultures at 28 and 20°C (because few data are available). We then carried out sequential fermentations at 20°C with S. cerevisiae, to assess the impact of the non-Saccharomyces yeasts on the availability of assimilable nitrogen for S. cerevisiae. Finally, 22 volatile compounds were quantified in sequential fermentation and their levels compared with those in pure cultures of S. cerevisiae. We report here, for the first time, that non-Saccharomyces yeasts have specific amino-acid consumption profiles. Histidine, methionine, threonine, and tyrosine were not consumed by S. bacillaris, aspartic acid was assimilated very slowly by M. pulcherrima, and glutamine was not assimilated by P. membranifaciens. By contrast, cysteine appeared to be a preferred nitrogen source for all non-Saccharomyces yeasts. In sequential fermentation, these specific profiles of amino-acid consumption by non-Saccharomyces yeasts may account for some of the interactions observed here, such as poorer performances of S. cerevisiae and volatile profile changes. PMID:29163451
Gobert, Antoine; Tourdot-Maréchal, Raphaëlle; Morge, Christophe; Sparrow, Céline; Liu, Youzhong; Quintanilla-Casas, Beatriz; Vichi, Stefania; Alexandre, Hervé
2017-01-01
Nitrogen sources in the must are important for yeast metabolism, growth, and performance, and wine volatile compounds profile. Yeast assimilable nitrogen (YAN) deficiencies in grape must are one of the main causes of stuck and sluggish fermentation. The nitrogen requirement of Saccharomyces cerevisiae metabolism has been described in detail. However, the YAN preferences of non- Saccharomyces yeasts remain unknown despite their increasingly widespread use in winemaking. Furthermore, the impact of nitrogen consumption by non- Saccharomyces yeasts on YAN availability, alcoholic performance and volatile compounds production by S. cerevisiae in sequential fermentation has been little studied. With a view to improving the use of non- Saccharomyces yeasts in winemaking, we studied the use of amino acids and ammonium by three strains of non- Saccharomyces yeasts ( Starmerella bacillaris, Metschnikowia pulcherrima , and Pichia membranifaciens ) in grape juice. We first determined which nitrogen sources were preferentially used by these yeasts in pure cultures at 28 and 20°C (because few data are available). We then carried out sequential fermentations at 20°C with S. cerevisiae , to assess the impact of the non- Saccharomyces yeasts on the availability of assimilable nitrogen for S. cerevisiae . Finally, 22 volatile compounds were quantified in sequential fermentation and their levels compared with those in pure cultures of S. cerevisiae . We report here, for the first time, that non- Saccharomyces yeasts have specific amino-acid consumption profiles. Histidine, methionine, threonine, and tyrosine were not consumed by S. bacillaris , aspartic acid was assimilated very slowly by M. pulcherrima , and glutamine was not assimilated by P. membranifaciens . By contrast, cysteine appeared to be a preferred nitrogen source for all non- Saccharomyces yeasts. In sequential fermentation, these specific profiles of amino-acid consumption by non- Saccharomyces yeasts may account for some of the interactions observed here, such as poorer performances of S. cerevisiae and volatile profile changes.
Thermal cracking of poly α-olefin aviation lubricating base oil
NASA Astrophysics Data System (ADS)
Fei, Yiwei; Wu, Nan; Ma, Jun; Hao, Jingtuan
2018-02-01
Thermal cracking of poly α-olefin (PAO) was conducted under different temperatures among 190 °C to 300 °C. The reacted mixtures were sequentially detected by gas chromatography-mass spectrometer (GC/MS). A series of small molecular normal alkanes, branched alkanes and olefins were identified. PAO perfect structure of aligned comb-likely side-chains has been seriously cracked under high temperatures. Property changes about kinematic viscosity and pour point of PAO samples reacted under high temperatures were also investigated. The appearance of small molecular compounds weakened the thermal stability, viscosity temperature performance and low temperature fluidity of PAO samples. Property of PAO samples was deteriorated due to thermal cracking under high temperatures.
dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C
2010-03-01
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.
Estenssoro, Elisa; Kanoore Edul, Vanina S; Loudet, Cecilia I; Osatnik, Javier; Ríos, Fernando G; Vázquez, Daniela N; Pozo, Mario O; Lattanzio, Bernardo; Pálizas, Fernando; Klein, Francisco; Piezny, Damián; Rubatto Birri, Paolo N; Tuhay, Graciela; Díaz, Anatilde; Santamaría, Analía; Zakalik, Graciela; Dubin, Arnaldo
2018-05-08
The new Sepsis-3 definitions have been scarcely assessed in low- and middle-income countries; besides, regional information of sepsis outcomes is sparse. Our objective was to evaluate Sepsis-3 definition performance in Argentina. Cohort study of 3-month duration beginning on July 1, 2016. Forty-nine ICUs. Consecutive patients admitted to the ICU with suspected infection that triggered blood cultures and antibiotic administration. None. Patients were classified as having infection, sepsis (infection + change in Sequential Organ Failure Assessment ≥ 2 points), and septic shock (vasopressors + lactate > 2 mmol/L). Patients on vasopressors and lactate less than or equal to 2 mmol/L (cardiovascular dysfunction) were analyzed separately, as those on vasopressors without serum lactate measurement. Systemic inflammatory response syndrome was also recorded. Main outcome was hospital mortality. Of 809 patients, 6% had infection, 29% sepsis, 20% cardiovascular dysfunction, 40% septic shock, and 3% received vasopressors with lactate unmeasured. Hospital mortality was 13%, 20%, 39%, 51%, and 41%, respectively (p = 0.000). Independent predictors of outcome were lactate, Sequential Organ Failure Assessment score, comorbidities, prior duration of symptoms (hr), mechanical ventilation requirement, and infection by highly resistant microorganisms. Area under the receiver operating characteristic curves for mortality for systemic inflammatory response syndrome and Sequential Organ Failure Assessment were 0.53 (0.48-0.55) and 0.74 (0.69-0.77), respectively (p = 0.000). Increasing severity of Sepsis-3 categories adequately tracks mortality; cardiovascular dysfunction subgroup, not included in Sepsis-3, has distinct characteristics. Sequential Organ Failure Assessment score shows adequate prognosis accuracy-contrary to systemic inflammatory response syndrome. This study supports the predictive validity of Sepsis-3 definitions.
Decoding-Accuracy-Based Sequential Dimensionality Reduction of Spatio-Temporal Neural Activities
NASA Astrophysics Data System (ADS)
Funamizu, Akihiro; Kanzaki, Ryohei; Takahashi, Hirokazu
Performance of a brain machine interface (BMI) critically depends on selection of input data because information embedded in the neural activities is highly redundant. In addition, properly selected input data with a reduced dimension leads to improvement of decoding generalization ability and decrease of computational efforts, both of which are significant advantages for the clinical applications. In the present paper, we propose an algorithm of sequential dimensionality reduction (SDR) that effectively extracts motor/sensory related spatio-temporal neural activities. The algorithm gradually reduces input data dimension by dropping neural data spatio-temporally so as not to undermine the decoding accuracy as far as possible. Support vector machine (SVM) was used as the decoder, and tone-induced neural activities in rat auditory cortices were decoded into the test tone frequencies. SDR reduced the input data dimension to a quarter and significantly improved the accuracy of decoding of novel data. Moreover, spatio-temporal neural activity patterns selected by SDR resulted in significantly higher accuracy than high spike rate patterns or conventionally used spatial patterns. These results suggest that the proposed algorithm can improve the generalization ability and decrease the computational effort of decoding.
Multilevel Mixture Kalman Filter
NASA Astrophysics Data System (ADS)
Guo, Dong; Wang, Xiaodong; Chen, Rong
2004-12-01
The mixture Kalman filter is a general sequential Monte Carlo technique for conditional linear dynamic systems. It generates samples of some indicator variables recursively based on sequential importance sampling (SIS) and integrates out the linear and Gaussian state variables conditioned on these indicators. Due to the marginalization process, the complexity of the mixture Kalman filter is quite high if the dimension of the indicator sampling space is high. In this paper, we address this difficulty by developing a new Monte Carlo sampling scheme, namely, the multilevel mixture Kalman filter. The basic idea is to make use of the multilevel or hierarchical structure of the space from which the indicator variables take values. That is, we draw samples in a multilevel fashion, beginning with sampling from the highest-level sampling space and then draw samples from the associate subspace of the newly drawn samples in a lower-level sampling space, until reaching the desired sampling space. Such a multilevel sampling scheme can be used in conjunction with the delayed estimation method, such as the delayed-sample method, resulting in delayed multilevel mixture Kalman filter. Examples in wireless communication, specifically the coherent and noncoherent 16-QAM over flat-fading channels, are provided to demonstrate the performance of the proposed multilevel mixture Kalman filter.
Removal of ion-implanted photoresists on GaAs using two organic solvents in sequence
NASA Astrophysics Data System (ADS)
Oh, Eunseok; Na, Jihoon; Lee, Seunghyo; Lim, Sangwoo
2016-07-01
Organic solvents can effectively remove photoresists on III-V channels without damage or etching of the channel material during the process. In this study, a two-step sequential photoresist removal process using two different organic solvents was developed to remove implanted ArF and KrF photoresists at room temperature. The effects of organic solvents with either low molar volumes or high affinities for photoresists were evaluated to find a proper combination that can effectively remove high-dose implanted photoresists without damaging GaAs surfaces. The performance of formamide, acetonitrile, nitromethane, and monoethanolamine for the removal of ion-implanted ArF and KrF photoresists were compared using a two-step sequential photoresist removal process followed by treatment in dimethyl sulfoxide (DMSO). Among the various combinations, the acetonitrile + DMSO two-step sequence exhibited the best removal of photoresists that underwent ion implantation at doses of 5 × 1013-5 × 1015 atoms/cm2 on both flat and trench-structured GaAs surfaces. The ability of the two-step process using organic solvents to remove the photoresists can be explained by considering the affinities of solvents for a polymer and its permeability through the photoresist.
NASA Astrophysics Data System (ADS)
Kim, Jin Wook; You, Seung Il; Kim, Nam Ho; Yoon, Ju-An; Cheah, Kok Wai; Zhu, Fu Rong; Kim, Woo Young
2014-11-01
In this study, we report our effort to realize high performance single emissive layer three color white phosphorescent organic light emitting diodes (PHOLEDs) through sequential Dexter energy transfer of blue, green and red dopants. The PHOLEDs had a structure of; ITO(1500 Å)/NPB(700 Å)/mCP:Firpic-x%:Ir(ppy)3-0.5%:Ir(piq)3-y%(300 Å)/TPBi(300 Å)/Liq(20 Å)/Al(1200 Å). The dopant concentrations of FIrpic, Ir(ppy)3 and Ir(piq)3 were adjusted and optimized to facilitate the preferred energy transfer processes attaining both the best luminous efficiency and CIE color coordinates. The presence of a deep trapping center for charge carriers in the emissive layer was confirmed by the observed red shift in electroluminescent spectra. White PHOLEDs, with phosphorescent dopant concentrations of FIrpic-8.0%:Ir(ppy)3-0.5%:Ir(piq)3-0.5% in the mCP host of the single emissive layer, had a maximum luminescence of 37,810 cd/m2 at 11 V and a luminous efficiency of 48.10 cd/A at 5 V with CIE color coordinates of (0.35, 0.41).
Scalable Parallel Density-based Clustering and Applications
NASA Astrophysics Data System (ADS)
Patwary, Mostofa Ali
2014-04-01
Recently, density-based clustering algorithms (DBSCAN and OPTICS) have gotten significant attention of the scientific community due to their unique capability of discovering arbitrary shaped clusters and eliminating noise data. These algorithms have several applications, which require high performance computing, including finding halos and subhalos (clusters) from massive cosmology data in astrophysics, analyzing satellite images, X-ray crystallography, and anomaly detection. However, parallelization of these algorithms are extremely challenging as they exhibit inherent sequential data access order, unbalanced workload resulting in low parallel efficiency. To break the data access sequentiality and to achieve high parallelism, we develop new parallel algorithms, both for DBSCAN and OPTICS, designed using graph algorithmic techniques. For example, our parallel DBSCAN algorithm exploits the similarities between DBSCAN and computing connected components. Using datasets containing up to a billion floating point numbers, we show that our parallel density-based clustering algorithms significantly outperform the existing algorithms, achieving speedups up to 27.5 on 40 cores on shared memory architecture and speedups up to 5,765 using 8,192 cores on distributed memory architecture. In our experiments, we found that while achieving the scalability, our algorithms produce clustering results with comparable quality to the classical algorithms.
Quantity judgments of sequentially presented food items by capuchin monkeys (Cebus apella).
Evans, Theodore A; Beran, Michael J; Harris, Emily H; Rice, Daniel F
2009-01-01
Recent assessments have shown that capuchin monkeys, like chimpanzees and other Old World primate species, are sensitive to quantitative differences between sets of visible stimuli. In the present study, we examined capuchins' performance in a more sophisticated quantity judgment task that required the ability to form representations of food quantities while viewing the quantities only one piece at a time. In three experiments, we presented monkeys with the choice between two sets of discrete homogeneous food items and allowed the monkeys to consume the set of their choice. In Experiments 1 and 2, monkeys compared an entirely visible food set to a second set, presented item-by-item into an opaque container. All monkeys exhibited high accuracy in choosing the larger set, even when the entirely visible set was presented last, preventing the use of one-to-one item correspondence to compare quantities. In Experiment 3, monkeys compared two sets that were each presented item-by-item into opaque containers, but at different rates to control for temporal cues. Some monkeys performed well in this experiment, though others exhibited near-chance performance, suggesting that this species' ability to form representations of food quantities may be limited compared to previously tested species such as chimpanzees. Overall, these findings support the analog magnitude model of quantity representation as an explanation for capuchin monkeys' quantification of sequentially presented food items.
NASA Astrophysics Data System (ADS)
Sharifi, Fereydoun; Arab-Amiri, Ali Reza; Kamkar-Rouhani, Abolghasem; Yousefi, Mahyar; Davoodabadi-Farahani, Meysam
2017-09-01
The purpose of this study is water prospectivity modeling (WPM) for recognizing karstic water-bearing zones by using analyses of geo-exploration data in Kal-Qorno valley, located in Tepal area, north of Iran. For this, a sequential exploration method applied on geo-evidential data to delineate target areas for further exploration. In this regard, two major exploration phases including regional and local scales were performed. In the first phase, indicator geological features, structures and lithological units, were used to model groundwater prospectivity as a regional scale. In this phase, for karstic WPM, fuzzy lithological and structural evidence layers were generated and combined using fuzzy operators. After generating target areas using WPM, in the second phase geophysical surveys including gravimetry and geoelectrical resistivity were carried out on the recognized high potential zones as a local scale exploration. Finally the results of geophysical analyses in the second phase were used to select suitable drilling locations to access and extract karstic groundwater in the study area.
A comparison of SuperLU solvers on the intel MIC architecture
NASA Astrophysics Data System (ADS)
Tuncel, Mehmet; Duran, Ahmet; Celebi, M. Serdar; Akaydin, Bora; Topkaya, Figen O.
2016-10-01
In many science and engineering applications, problems may result in solving a sparse linear system AX=B. For example, SuperLU_MCDT, a linear solver, was used for the large penta-diagonal matrices for 2D problems and hepta-diagonal matrices for 3D problems, coming from the incompressible blood flow simulation (see [1]). It is important to test the status and potential improvements of state-of-the-art solvers on new technologies. In this work, sequential, multithreaded and distributed versions of SuperLU solvers (see [2]) are examined on the Intel Xeon Phi coprocessors using offload programming model at the EURORA cluster of CINECA in Italy. We consider a portfolio of test matrices containing patterned matrices from UFMM ([3]) and randomly located matrices. This architecture can benefit from high parallelism and large vectors. We find that the sequential SuperLU benefited up to 45 % performance improvement from the offload programming depending on the sparse matrix type and the size of transferred and processed data.
NASA Technical Reports Server (NTRS)
Charlesworth, Arthur
1990-01-01
The nondeterministic divide partitions a vector into two non-empty slices by allowing the point of division to be chosen nondeterministically. Support for high-level divide-and-conquer programming provided by the nondeterministic divide is investigated. A diva algorithm is a recursive divide-and-conquer sequential algorithm on one or more vectors of the same range, whose division point for a new pair of recursive calls is chosen nondeterministically before any computation is performed and whose recursive calls are made immediately after the choice of division point; also, access to vector components is only permitted during activations in which the vector parameters have unit length. The notion of diva algorithm is formulated precisely as a diva call, a restricted call on a sequential procedure. Diva calls are proven to be intimately related to associativity. Numerous applications of diva calls are given and strategies are described for translating a diva call into code for a variety of parallel computers. Thus diva algorithms separate logical correctness concerns from implementation concerns.
Tri-state delta modulation system for Space Shuttle digital TV downlink
NASA Technical Reports Server (NTRS)
Udalov, S.; Huth, G. K.; Roberts, D.; Batson, B. H.
1981-01-01
Future requirements for Shuttle Orbiter downlink communication may include transmission of digital video which, in addition to black and white, may also be either field-sequential or NTSC color format. The use of digitized video could provide for picture privacy at the expense of additional onboard hardware, together with an increased bandwidth due to the digitization process. A general objective for the Space Shuttle application is to develop a digitization technique that is compatible with data rates in the 20-30 Mbps range but still provides good quality pictures. This paper describes a tri-state delta modulation/demodulation (TSDM) technique which is a good compromise between implementation complexity and performance. The unique feature of TSDM is that it provides for efficient run-length encoding of constant-intensity segments of a TV picture. Axiomatix has developed a hardware implementation of a high-speed TSDM transmitter and receiver for black-and-white TV and field-sequential color. The hardware complexity of this TSDM implementation is summarized in the paper.
Field-Sequential Electronic Stereoscopic Projector
NASA Astrophysics Data System (ADS)
Lipton, Lenny
1989-07-01
Culminating a research and development project spanning many years, StereoGraphics Corporation has succeeded in bringing to market the first field-sequential electronic stereoscopic projector. The product is based on a modification of Electrohome and Barco projectors. Our design goal was to produce a projector capable of displaying an image on a six-foot (or larger) diagonal screen for an audience of 50 or 60 people, or for an individual using a simulator. A second goal was to produce an image that required only passive polarizing glasses rather than powered, tethered visors. Two major design challenges posed themselves. First, it was necessary to create an electro-optical modulator which could switch the characteristic of polarized light at field rate, and second, it was necessary to produce a bright green CRT with short persistence to prevent crosstalk between left and right fields. To solve the first problem, development was undertaken to produce the required electro-optical modulator. The second problem was solved with the help of a vendor specializing in high performance CRT's.
Rollero, Stephanie; Bloem, Audrey; Ortiz-Julien, Anne; Camarasa, Carole; Divol, Benoit
2018-01-01
The sequential inoculation of non-Saccharomyces yeasts and Saccharomyces cerevisiae in grape juice is becoming an increasingly popular practice to diversify wine styles and/or to obtain more complex wines with a peculiar microbial footprint. One of the main interactions is competition for nutrients, especially nitrogen sources, that directly impacts not only fermentation performance but also the production of aroma compounds. In order to better understand the interactions taking place between non-Saccharomyces yeasts and S. cerevisiae during alcoholic fermentation, sequential inoculations of three yeast species (Pichia burtonii, Kluyveromyces marxianus, Zygoascus meyerae) with S. cerevisiae were performed individually in a synthetic medium. Different species-dependent interactions were evidenced. Indeed, the three sequential inoculations resulted in three different behaviors in terms of growth. P. burtonii and Z. meyerae declined after the inoculation of S. cerevisiae which promptly outcompeted the other two species. However, while the presence of P. burtonii did not impact the fermentation kinetics of S. cerevisiae, that of Z. meyerae rendered the overall kinetics very slow and with no clear exponential phase. K. marxianus and S. cerevisiae both declined and became undetectable before fermentation completion. The results also demonstrated that yeasts differed in their preference for nitrogen sources. Unlike Z. meyerae and P. burtonii, K. marxianus appeared to be a competitor for S. cerevisiae (as evidenced by the uptake of ammonium and amino acids), thereby explaining the resulting stuck fermentation. Nevertheless, the results suggested that competition for other nutrients (probably vitamins) occurred during the sequential inoculation of Z. meyerae with S. cerevisiae. The metabolic footprint of the non-Saccharomyces yeasts determined after 48 h of fermentation remained until the end of fermentation and combined with that of S. cerevisiae. For instance, fermentations performed with K. marxianus were characterized by the formation of phenylethanol and phenylethyl acetate, while those performed with P. burtonii or Z. meyerae displayed higher production of isoamyl alcohol and ethyl esters. When considering sequential inoculation of yeasts, the nutritional requirements of the yeasts used should be carefully considered and adjusted accordingly. Finally, our chemical data suggests that the organoleptic properties of the wine are altered in a species specific manner. PMID:29487584
Grieco-Calub, Tina M.; Litovsky, Ruth Y.
2010-01-01
Objectives To measure sound source localization in children who have sequential bilateral cochlear implants (BICIs); to determine if localization accuracy correlates with performance on a right-left discrimination task (i.e., spatial acuity); to determine if there is a measurable bilateral benefit on a sound source identification task (i.e., localization accuracy) by comparing performance under bilateral and unilateral listening conditions; to determine if sound source localization continues to improve with longer durations of bilateral experience. Design Two groups of children participated in this study: a group of 21 children who received BICIs in sequential procedures (5–14 years old) and a group of 7 typically-developing children with normal acoustic hearing (5 years old). Testing was conducted in a large sound-treated booth with loudspeakers positioned on a horizontal arc with a radius of 1.2 m. Children participated in two experiments that assessed spatial hearing skills. Spatial hearing acuity was assessed with a discrimination task in which listeners determined if a sound source was presented on the right or left side of center; the smallest angle at which performance on this task was reliably above chance is the minimum audible angle. Sound localization accuracy was assessed with a sound source identification task in which children identified the perceived position of the sound source from a multi-loudspeaker array (7 or 15); errors are quantified using the root-mean-square (RMS) error. Results Sound localization accuracy was highly variable among the children with BICIs, with RMS errors ranging from 19°–56°. Performance of the NH group, with RMS errors ranging from 9°–29° was significantly better. Within the BICI group, in 11/21 children RMS errors were smaller in the bilateral vs. unilateral listening condition, indicating bilateral benefit. There was a significant correlation between spatial acuity and sound localization accuracy (R2=0.68, p<0.01), suggesting that children who achieve small RMS errors tend to have the smallest MAAs. Although there was large intersubject variability, testing of 11 children in the BICI group at two sequential visits revealed a subset of children who show improvement in spatial hearing skills over time. Conclusions A subset of children who use sequential BICIs can acquire sound localization abilities, even after long intervals between activation of hearing in the first- and second-implanted ears. This suggests that children with activation of the second implant later in life may be capable of developing spatial hearing abilities. The large variability in performance among the children with BICIs suggests that maturation of sound localization abilities in children with BICIs may be dependent on various individual subject factors such as age of implantation and chronological age. PMID:20592615
User-Defined Data Distributions in High-Level Programming Languages
NASA Technical Reports Server (NTRS)
Diaconescu, Roxana E.; Zima, Hans P.
2006-01-01
One of the characteristic features of today s high performance computing systems is a physically distributed memory. Efficient management of locality is essential for meeting key performance requirements for these architectures. The standard technique for dealing with this issue has involved the extension of traditional sequential programming languages with explicit message passing, in the context of a processor-centric view of parallel computation. This has resulted in complex and error-prone assembly-style codes in which algorithms and communication are inextricably interwoven. This paper presents a high-level approach to the design and implementation of data distributions. Our work is motivated by the need to improve the current parallel programming methodology by introducing a paradigm supporting the development of efficient and reusable parallel code. This approach is currently being implemented in the context of a new programming language called Chapel, which is designed in the HPCS project Cascade.
Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L
2010-02-15
Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.
Shuttle GPS R/PA evaluation analysis and performance tradeoff study
NASA Technical Reports Server (NTRS)
Booth, R. W. D.; Lindsey, W. C.
1978-01-01
Primary responsibility was understanding and analyzing the various GPS receiver functions as they relate to the shuttle environment. These receiver functions included acquisition properties of the sequential detector, acquisition and tracking properties of the various receiver phase locked loops, and the techniques of sequential receiver operation. In addition to these areas, support was provided in the areas of oscillator stability requirements, antenna management, and navigation filter requirements, including preposition aiding.
Computational Cognitive Neuroscience Modeling of Sequential Skill Learning
2016-09-21
101 EAST 27TH STREET STE 4308 AUSTIN , TX 78712 09/21/2016 Final Report DISTRIBUTION A: Distribution approved for public release. Air Force Research ...5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) The University of Texas at Austin 108 E Dean Keeton Stop A8000 Austin , TX ...AFRL-AFOSR-VA-TR-2016-0320 Computational Cognitive Neuroscience Modeling of Sequential Skill Learning David Schnyer UNIVERSITY OF TEXAS AT AUSTIN
Separation of chemical groups from bio-oil aqueous phase via sequential organic solvent extraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Shoujie; Ye, Philip; Borole, Abhijeet P
Bio-oil aqueous phase contains a considerable amount of furans, alcohols, ketones, aldehydes and phenolics besides the major components of organic acids and anhydrosugars. The complexity of bio-oil aqueous phase limits its efficient utilization. To improve the efficiency of bio-oil biorefinery, this study focused on the separation of chemical groups from bio-oil aqueous phase via sequential organic solvent extractions. Due to their high recoverability and low solubility in water, four solvents (hexane, petroleum ether, chloroform, and ethyl acetate) with different polarities were evaluated, and the optimum process conditions for chemical extraction were determined. Chloroform had high extraction efficiency for furans, phenolics,more » and ketones. In addition to these chemical groups, ethyl acetate had high extraction efficiency for organic acids. The sequential extraction by using chloroform followed by ethyl acetate rendered that 62.2 wt.% of original furans, ketones, alcohols, and phenolics were extracted to chloroform, over 62 wt.% acetic acid was extracted to ethyl acetate, resulting in a high concentration of levoglucosan (~53.0 wt.%) in the final aqueous phase. Chemicals separated via the sequential extraction could be used as feedstocks in biorefinery using processes such as catalytic upgrading of furans and phenolics to hydrocarbons, fermentation of levoglucosan to produce alcohols and diols, and hydrogen production from organic acids via microbial electrolysis.« less
Separation of chemical groups from bio-oil aqueous phase via sequential organic solvent extraction
Ren, Shoujie; Ye, Philip; Borole, Abhijeet P
2017-01-05
Bio-oil aqueous phase contains a considerable amount of furans, alcohols, ketones, aldehydes and phenolics besides the major components of organic acids and anhydrosugars. The complexity of bio-oil aqueous phase limits its efficient utilization. To improve the efficiency of bio-oil biorefinery, this study focused on the separation of chemical groups from bio-oil aqueous phase via sequential organic solvent extractions. Due to their high recoverability and low solubility in water, four solvents (hexane, petroleum ether, chloroform, and ethyl acetate) with different polarities were evaluated, and the optimum process conditions for chemical extraction were determined. Chloroform had high extraction efficiency for furans, phenolics,more » and ketones. In addition to these chemical groups, ethyl acetate had high extraction efficiency for organic acids. The sequential extraction by using chloroform followed by ethyl acetate rendered that 62.2 wt.% of original furans, ketones, alcohols, and phenolics were extracted to chloroform, over 62 wt.% acetic acid was extracted to ethyl acetate, resulting in a high concentration of levoglucosan (~53.0 wt.%) in the final aqueous phase. Chemicals separated via the sequential extraction could be used as feedstocks in biorefinery using processes such as catalytic upgrading of furans and phenolics to hydrocarbons, fermentation of levoglucosan to produce alcohols and diols, and hydrogen production from organic acids via microbial electrolysis.« less
A Novel Ship-Tracking Method for GF-4 Satellite Sequential Images.
Yao, Libo; Liu, Yong; He, You
2018-06-22
The geostationary remote sensing satellite has the capability of wide scanning, persistent observation and operational response, and has tremendous potential for maritime target surveillance. The GF-4 satellite is the first geostationary orbit (GEO) optical remote sensing satellite with medium resolution in China. In this paper, a novel ship-tracking method in GF-4 satellite sequential imagery is proposed. The algorithm has three stages. First, a local visual saliency map based on local peak signal-to-noise ratio (PSNR) is used to detect ships in a single frame of GF-4 satellite sequential images. Second, the accuracy positioning of each potential target is realized by a dynamic correction using the rational polynomial coefficients (RPCs) and automatic identification system (AIS) data of ships. Finally, an improved multiple hypotheses tracking (MHT) algorithm with amplitude information is used to track ships by further removing the false targets, and to estimate ships’ motion parameters. The algorithm has been tested using GF-4 sequential images and AIS data. The results of the experiment demonstrate that the algorithm achieves good tracking performance in GF-4 satellite sequential images and estimates the motion information of ships accurately.
Yuan, X-G; Zhang, X; Fu, Y-X; Tian, X-F; Liu, Y; Xiao, J; Li, T-W; Qiu, L
2016-05-01
To evaluate the efficacy of a "vacuum sealing drainage (VSD) - artificial dermis implantation (ADI) - thin partial thickness skin grafting (TSG)" sequential therapy for deep and infected wounds in children. Fifty-three pediatric patients with deep and infected wounds were treated with sequential VSD-ADI-TSG therapy. The efficacy of this treatment was compared with that of the surgical debridement-change dressings-thin partial thickness skin grafting previously performed on 20 patients. Survival of tissue grafts, color and flexibility, subcutaneous fullness and scar formation of the graft site were examined and compared. The sequential therapy combined the advantages of the VSD treatment, in reducing tissue necrosis and infection on the wound surfaces and promoting the growth of granulation tissue, with the enhancement of grafting by artificial dermis. Compared with the 20 controls, skin grafted on the artificial dermis was more smooth and glossy, while the textures of the region were more elastic, and the scars were significantly lighter in Vancouver scale. The sequential VSD-ADI-TSG therapy is a simple and effective treatment for children with deep and infected wounds. IV. Copyright © 2016. Published by Elsevier Masson SAS.
Chung, Sukhoon; Rhee, Hyunsill; Suh, Yongmoo
2010-01-01
Objectives This study sought to find answers to the following questions: 1) Can we predict whether a patient will revisit a healthcare center? 2) Can we anticipate diseases of patients who revisit the center? Methods For the first question, we applied 5 classification algorithms (decision tree, artificial neural network, logistic regression, Bayesian networks, and Naïve Bayes) and the stacking-bagging method for building classification models. To solve the second question, we performed sequential pattern analysis. Results We determined: 1) In general, the most influential variables which impact whether a patient of a public healthcare center will revisit it or not are personal burden, insurance bill, period of prescription, age, systolic pressure, name of disease, and postal code. 2) The best plain classification model is dependent on the dataset. 3) Based on average of classification accuracy, the proposed stacking-bagging method outperformed all traditional classification models and our sequential pattern analysis revealed 16 sequential patterns. Conclusions Classification models and sequential patterns can help public healthcare centers plan and implement healthcare service programs and businesses that are more appropriate to local residents, encouraging them to revisit public health centers. PMID:21818426
NASA Technical Reports Server (NTRS)
Habibi, A.; Batson, B.
1976-01-01
Space Shuttle will be using a field-sequential color television system for the first few missions, but the present plans are to switch to a NTSC color TV system for future missions. The field-sequential color TV system uses a modified black and white camera, producing a TV signal with a digital bandwidth of about 60 Mbps. This article discusses the characteristics of the Shuttle TV systems and proposes a bandwidth-compression technique for the field-sequential color TV system that could operate at 13 Mbps to produce a high-fidelity signal. The proposed bandwidth-compression technique is based on a two-dimensional DPCM system that utilizes temporal, spectral, and spatial correlation inherent in the field-sequential color TV imagery. The proposed system requires about 60 watts and less than 200 integrated circuits.
The sequential structure of brain activation predicts skill.
Anderson, John R; Bothell, Daniel; Fincham, Jon M; Moon, Jungaa
2016-01-29
In an fMRI study, participants were trained to play a complex video game. They were scanned early and then again after substantial practice. While better players showed greater activation in one region (right dorsal striatum) their relative skill was better diagnosed by considering the sequential structure of whole brain activation. Using a cognitive model that played this game, we extracted a characterization of the mental states that are involved in playing a game and the statistical structure of the transitions among these states. There was a strong correspondence between this measure of sequential structure and the skill of different players. Using multi-voxel pattern analysis, it was possible to recognize, with relatively high accuracy, the cognitive states participants were in during particular scans. We used the sequential structure of these activation-recognized states to predict the skill of individual players. These findings indicate that important features about information-processing strategies can be identified from a model-based analysis of the sequential structure of brain activation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Two-step sequential pretreatment for the enhanced enzymatic hydrolysis of coffee spent waste.
Ravindran, Rajeev; Jaiswal, Swarna; Abu-Ghannam, Nissreen; Jaiswal, Amit K
2017-09-01
In the present study, eight different pretreatments of varying nature (physical, chemical and physico-chemical) followed by a sequential, combinatorial pretreatment strategy was applied to spent coffee waste to attain maximum sugar yield. Pretreated samples were analysed for total reducing sugar, individual sugars and generation of inhibitory compounds such as furfural and hydroxymethyl furfural (HMF) which can hinder microbial growth and enzyme activity. Native spent coffee waste was high in hemicellulose content. Galactose was found to be the predominant sugar in spent coffee waste. Results showed that sequential pretreatment yielded 350.12mg of reducing sugar/g of substrate, which was 1.7-fold higher than in native spent coffee waste (203.4mg/g of substrate). Furthermore, extensive delignification was achieved using sequential pretreatment strategy. XRD, FTIR, and DSC profiles of the pretreated substrates were studied to analyse the various changes incurred in sequentially pretreated spent coffee waste as opposed to native spent coffee waste. Copyright © 2017 Elsevier Ltd. All rights reserved.
Button, Le; Peter, Beate; Stoel-Gammon, Carol; Raskind, Wendy H
2013-03-01
The purpose of this study was to address the hypothesis that childhood apraxia of speech (CAS) is influenced by an underlying deficit in sequential processing that is also expressed in other modalities. In a sample of 21 adults from five multigenerational families, 11 with histories of various familial speech sound disorders, 3 biologically related adults from a family with familial CAS showed motor sequencing deficits in an alternating motor speech task. Compared with the other adults, these three participants showed deficits in tasks requiring high loads of sequential processing, including nonword imitation, nonword reading and spelling. Qualitative error analyses in real word and nonword imitations revealed group differences in phoneme sequencing errors. Motor sequencing ability was correlated with phoneme sequencing errors during real word and nonword imitation, reading and spelling. Correlations were characterized by extremely high scores in one family and extremely low scores in another. Results are consistent with a central deficit in sequential processing in CAS of familial origin.
BUTTON, LE; PETER, BEATE; STOEL-GAMMON, CAROL; RASKIND, WENDY H.
2013-01-01
The purpose of this study was to address the hypothesis that childhood apraxia of speech (CAS) is influenced by an underlying deficit in sequential processing that is also expressed in other modalities. In a sample of 21 adults from five multigenerational families, 11 with histories of various familial speech sound disorders, 3 biologically related adults from a family with familial CAS showed motor sequencing deficits in an alternating motor speech task. Compared with the other adults, these three participants showed deficits in tasks requiring high loads of sequential processing, including nonword imitation, nonword reading and spelling. Qualitative error analyses in real word and nonword imitations revealed group differences in phoneme sequencing errors. Motor sequencing ability was correlated with phoneme sequencing errors during real word and nonword imitation, reading and spelling. Correlations were characterized by extremely high scores in one family and extremely low scores in another. Results are consistent with a central deficit in sequential processing in CAS of familial origin. PMID:23339292
Chocholouš, Petr; Kosařová, Lucie; Satínský, Dalibor; Sklenářová, Hana; Solich, Petr
2011-08-15
In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis(®) Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith(®) Performance RP-18e 100-3 (Merck(®)) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab(®), USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min(-1). Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Synovec, R.E.; Johnson, E.L.; Bahowick, T.J.
1990-08-01
This paper describes a new technique for data analysis in chromatography, based on taking the point-by-point ratio of sequential chromatograms that have been base line corrected. This ratio chromatogram provides a robust means for the identification and the quantitation of analytes. In addition, the appearance of an interferent is made highly visible, even when it coelutes with desired analytes. For quantitative analysis, the region of the ratio chromatogram corresponding to the pure elution of an analyte is identified and is used to calculate a ratio value equal to the ratio of concentrations of the analyte in sequential injections. For themore » ratio value calculation, a variance-weighted average is used, which compensates for the varying signal-to-noise ratio. This ratio value, or equivalently the percent change in concentration, is the basis of a chromatographic standard addition method and an algorithm to monitor analyte concentration in a process stream. In the case of overlapped peaks, a spiking procedure is used to calculate both the original concentration of an analyte and its signal contribution to the original chromatogram. Thus, quantitation and curve resolution may be performed simultaneously, without peak modeling or curve fitting. These concepts are demonstrated by using data from ion chromatography, but the technique should be applicable to all chromatographic techniques.« less
Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli; Brett, Bevin
2013-01-01
One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. In this work, we have developed a software platform that is designed to support high-performance 3D medical image processing for a wide range of applications using increasingly available and affordable commodity computing systems: multi-core, clusters, and cloud computing systems. To achieve scalable, high-performance computing, our platform (1) employs size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D image processing algorithms; (2) supports task scheduling for efficient load distribution and balancing; and (3) consists of a layered parallel software libraries that allow a wide range of medical applications to share the same functionalities. We evaluated the performance of our platform by applying it to an electronic cleansing system in virtual colonoscopy, with initial experimental results showing a 10 times performance improvement on an 8-core workstation over the original sequential implementation of the system. PMID:23366803
Comparison Between NIST and AF Laser Energy Standards Using High Power Lasers
Li, Xiaoyu; Scott (Retired), Thomas; Cromer, Chris; Cooper, David; Comisford, Steven
2007-01-01
We report the results of a high-energy laser calorimeter comparison conducted by the National Institute of Standards and Technology (NIST), Boulder, Colorado and the U.S. Air Force Primary Standards laboratory (AFPSL), Heath, Ohio. A laser power meter, used as a transfer standard, was calibrated at each laboratory, sequentially, and the measurement results were compared. These measurements were performed at a nominal power of 800 W and a wavelength of 10.6 μm using CO2 lasers. Excellent measurement agreement (1.02 %) was demonstrated, which was well within each of the expanded uncertainties from the two laboratories involved in this comparison. PMID:27110471
NASA Astrophysics Data System (ADS)
Gheorghiu, E.; Gheorghiu, M.; David, S.; Polonschii, C.
Chemical cues and nano-topographies present on the surface or in the extracellular medium strongly influence the fate and adhesion of biological cells. Careful tuning of cell—matrix interaction via engineered surfaces, either attractive or repulsive, require non-invasive, long time monitoring capabilities and lay the foundation of sensing platforms for risk assessment. Aiming to assess changes underwent by biointerfaces due to cell—environment interaction (in particular nanotechnology products), we have developed hybrid cellular platforms allowing for time based dual assays, i.e., impedance/dielectric spectroscopy (IS) and Surface Plasmon Resonance (SPR). Such platforms comprising Flow Injection Analysis (FIA) have been advanced to assess the interaction between selected (normal and malignant) cells and nano-patterned and/or chemically modified surfaces, as well as the impact of engineered nanoparticles, revealed by the related changes exhibited by cell membrane, morphology, adhesion and monolayer integrity. Besides experimental aspects dealing with measurement set-up, we will emphasize theoretical aspects related to: dielectric modeling. Aiming for a quantitative approach, microscopic models on dielectric behavior of ensembles of interconnected cells have been developed and their capabilities will be outlined within the presentation. Assessment of affinity reactions as revealed by dielectric/impedance assays of biointerfaces. Modeling the dynamics of the impedance in relation to the “quality” of cell layer and sensor's active surface, this study presents further developments of our approach described in Analytical Chemistry, 2002. Data analysis. This issue is related to the following basic question: Are there “simple” Biosensing Platforms? When coping with cellular platforms, either in suspension or immobilized (on filters, adhered on surfaces or entrapped, e.g., on using set-ups) there is an intrinsic nonlinear behavior of biological systems related to cellular mechanisms involved in sensing, i.e., adaptation to stimuli. This should not mean that when coping with living cells, stray effects might not also corrupt the measurement itself, introducing distinct dynamics. Besides targeted/specific process, analytical platforms might exhibit additional ones due to “stray influences” that could include the effect of, e.g.: supporting matrix, nonspecific binding and temperature variation. Stray processes interfere with the desired ones and the measured data could display a non-monotonous behavior.
Suppressing correlations in massively parallel simulations of lattice models
NASA Astrophysics Data System (ADS)
Kelling, Jeffrey; Ódor, Géza; Gemming, Sibylle
2017-11-01
For lattice Monte Carlo simulations parallelization is crucial to make studies of large systems and long simulation time feasible, while sequential simulations remain the gold-standard for correlation-free dynamics. Here, various domain decomposition schemes are compared, concluding with one which delivers virtually correlation-free simulations on GPUs. Extensive simulations of the octahedron model for 2 + 1 dimensional Kardar-Parisi-Zhang surface growth, which is very sensitive to correlation in the site-selection dynamics, were performed to show self-consistency of the parallel runs and agreement with the sequential algorithm. We present a GPU implementation providing a speedup of about 30 × over a parallel CPU implementation on a single socket and at least 180 × with respect to the sequential reference.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Odéen, Henrik, E-mail: h.odeen@gmail.com; Diakite, Mahamadou; Todd, Nick
2014-09-15
Purpose: To investigate k-space subsampling strategies to achieve fast, large field-of-view (FOV) temperature monitoring using segmented echo planar imaging (EPI) proton resonance frequency shift thermometry for MR guided high intensity focused ultrasound (MRgHIFU) applications. Methods: Five different k-space sampling approaches were investigated, varying sample spacing (equally vs nonequally spaced within the echo train), sampling density (variable sampling density in zero, one, and two dimensions), and utilizing sequential or centric sampling. Three of the schemes utilized sequential sampling with the sampling density varied in zero, one, and two dimensions, to investigate sampling the k-space center more frequently. Two of the schemesmore » utilized centric sampling to acquire the k-space center with a longer echo time for improved phase measurements, and vary the sampling density in zero and two dimensions, respectively. Phantom experiments and a theoretical point spread function analysis were performed to investigate their performance. Variable density sampling in zero and two dimensions was also implemented in a non-EPI GRE pulse sequence for comparison. All subsampled data were reconstructed with a previously described temporally constrained reconstruction (TCR) algorithm. Results: The accuracy of each sampling strategy in measuring the temperature rise in the HIFU focal spot was measured in terms of the root-mean-square-error (RMSE) compared to fully sampled “truth.” For the schemes utilizing sequential sampling, the accuracy was found to improve with the dimensionality of the variable density sampling, giving values of 0.65 °C, 0.49 °C, and 0.35 °C for density variation in zero, one, and two dimensions, respectively. The schemes utilizing centric sampling were found to underestimate the temperature rise, with RMSE values of 1.05 °C and 1.31 °C, for variable density sampling in zero and two dimensions, respectively. Similar subsampling schemes with variable density sampling implemented in zero and two dimensions in a non-EPI GRE pulse sequence both resulted in accurate temperature measurements (RMSE of 0.70 °C and 0.63 °C, respectively). With sequential sampling in the described EPI implementation, temperature monitoring over a 192 × 144 × 135 mm{sup 3} FOV with a temporal resolution of 3.6 s was achieved, while keeping the RMSE compared to fully sampled “truth” below 0.35 °C. Conclusions: When segmented EPI readouts are used in conjunction with k-space subsampling for MR thermometry applications, sampling schemes with sequential sampling, with or without variable density sampling, obtain accurate phase and temperature measurements when using a TCR reconstruction algorithm. Improved temperature measurement accuracy can be achieved with variable density sampling. Centric sampling leads to phase bias, resulting in temperature underestimations.« less
A Node Linkage Approach for Sequential Pattern Mining
Navarro, Osvaldo; Cumplido, René; Villaseñor-Pineda, Luis; Feregrino-Uribe, Claudia; Carrasco-Ochoa, Jesús Ariel
2014-01-01
Sequential Pattern Mining is a widely addressed problem in data mining, with applications such as analyzing Web usage, examining purchase behavior, and text mining, among others. Nevertheless, with the dramatic increase in data volume, the current approaches prove inefficient when dealing with large input datasets, a large number of different symbols and low minimum supports. In this paper, we propose a new sequential pattern mining algorithm, which follows a pattern-growth scheme to discover sequential patterns. Unlike most pattern growth algorithms, our approach does not build a data structure to represent the input dataset, but instead accesses the required sequences through pseudo-projection databases, achieving better runtime and reducing memory requirements. Our algorithm traverses the search space in a depth-first fashion and only preserves in memory a pattern node linkage and the pseudo-projections required for the branch being explored at the time. Experimental results show that our new approach, the Node Linkage Depth-First Traversal algorithm (NLDFT), has better performance and scalability in comparison with state of the art algorithms. PMID:24933123
Blocking for Sequential Political Experiments
Moore, Sally A.
2013-01-01
In typical political experiments, researchers randomize a set of households, precincts, or individuals to treatments all at once, and characteristics of all units are known at the time of randomization. However, in many other experiments, subjects “trickle in” to be randomized to treatment conditions, usually via complete randomization. To take advantage of the rich background data that researchers often have (but underutilize) in these experiments, we develop methods that use continuous covariates to assign treatments sequentially. We build on biased coin and minimization procedures for discrete covariates and demonstrate that our methods outperform complete randomization, producing better covariate balance in simulated data. We then describe how we selected and deployed a sequential blocking method in a clinical trial and demonstrate the advantages of our having done so. Further, we show how that method would have performed in two larger sequential political trials. Finally, we compare causal effect estimates from differences in means, augmented inverse propensity weighted estimators, and randomization test inversion. PMID:24143061
Tait, Jamie L.; Duckham, Rachel L.; Milte, Catherine M.; Main, Luana C.; Daly, Robin M.
2017-01-01
Emerging research indicates that exercise combined with cognitive training may improve cognitive function in older adults. Typically these programs have incorporated sequential training, where exercise and cognitive training are undertaken separately. However, simultaneous or dual-task training, where cognitive and/or motor training are performed simultaneously with exercise, may offer greater benefits. This review summary provides an overview of the effects of combined simultaneous vs. sequential training on cognitive function in older adults. Based on the available evidence, there are inconsistent findings with regard to the cognitive benefits of sequential training in comparison to cognitive or exercise training alone. In contrast, simultaneous training interventions, particularly multimodal exercise programs in combination with secondary tasks regulated by sensory cues, have significantly improved cognition in both healthy older and clinical populations. However, further research is needed to determine the optimal characteristics of a successful simultaneous training program for optimizing cognitive function in older people. PMID:29163146
Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko
2017-09-01
To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential BiCIs. A multicenter randomized clinical trial was conducted between January 12, 2010, and September 2, 2012, at 5 tertiary referral centers among 40 participants eligible for BiCIs. Main inclusion criteria were postlingual severe to profound hearing loss, age 18 to 70 years, and a maximum duration of 10 years without hearing aid use in both ears. Data analysis was conducted from May 24 to June 12, 2016. The simultaneous BiCI group received 2 cochlear implants during 1 surgical procedure. The sequential BiCI group received 2 cochlear implants with an interval of 2 years between implants. First, the results 1 year after receiving simultaneous BiCIs were compared with the results 1 year after receiving sequential BiCIs. Second, the results of 3 years of follow-up for both groups were compared separately. The primary outcome measure was speech intelligibility in noise from straight ahead. Secondary outcome measures were speech intelligibility in noise from spatially separated sources, speech intelligibility in silence, localization capabilities, and self-reported benefits assessed with various hearing and quality of life questionnaires. Nineteen participants were randomized to receive simultaneous BiCIs (11 women and 8 men; median age, 52 years [interquartile range, 36-63 years]), and another 19 participants were randomized to undergo sequential BiCIs (8 women and 11 men; median age, 54 years [interquartile range, 43-64 years]). Three patients did not receive a second cochlear implant and were unavailable for follow-up. Comparable results were found 1 year after simultaneous or sequential BiCIs for speech intelligibility in noise from straight ahead (difference, 0.9 dB [95% CI, -3.1 to 4.4 dB]) and all secondary outcome measures except for localization with a 30° angle between loudspeakers (difference, -10% [95% CI, -20.1% to 0.0%]). In the sequential BiCI group, all participants performed significantly better after the BiCIs on speech intelligibility in noise from spatially separated sources and on all localization tests, which was consistent with most of the participants' self-reported hearing capabilities. Speech intelligibility-in-noise results improved in the simultaneous BiCI group up to 3 years following the BiCIs. This study shows comparable objective and subjective hearing results 1 year after receiving simultaneous BiCIs and sequential BiCIs with an interval of 2 years between implants. It also shows a significant benefit of sequential BiCIs over a unilateral cochlear implant. Until 3 years after receiving simultaneous BiCIs, speech intelligibility in noise significantly improved compared with previous years. trialregister.nl Identifier: NTR1722.
Ultrasensitive surveillance of sensors and processes
Wegerich, Stephan W.; Jarman, Kristin K.; Gross, Kenneth C.
2001-01-01
A method and apparatus for monitoring a source of data for determining an operating state of a working system. The method includes determining a sensor (or source of data) arrangement associated with monitoring the source of data for a system, activating a method for performing a sequential probability ratio test if the data source includes a single data (sensor) source, activating a second method for performing a regression sequential possibility ratio testing procedure if the arrangement includes a pair of sensors (data sources) with signals which are linearly or non-linearly related; activating a third method for performing a bounded angle ratio test procedure if the sensor arrangement includes multiple sensors and utilizing at least one of the first, second and third methods to accumulate sensor signals and determining the operating state of the system.
Ultrasensitive surveillance of sensors and processes
Wegerich, Stephan W.; Jarman, Kristin K.; Gross, Kenneth C.
1999-01-01
A method and apparatus for monitoring a source of data for determining an operating state of a working system. The method includes determining a sensor (or source of data) arrangement associated with monitoring the source of data for a system, activating a method for performing a sequential probability ratio test if the data source includes a single data (sensor) source, activating a second method for performing a regression sequential possibility ratio testing procedure if the arrangement includes a pair of sensors (data sources) with signals which are linearly or non-linearly related; activating a third method for performing a bounded angle ratio test procedure if the sensor arrangement includes multiple sensors and utilizing at least one of the first, second and third methods to accumulate sensor signals and determining the operating state of the system.
Hybrid and concatenated coding applications.
NASA Technical Reports Server (NTRS)
Hofman, L. B.; Odenwalder, J. P.
1972-01-01
Results of a study to evaluate the performance and implementation complexity of a concatenated and a hybrid coding system for moderate-speed deep-space applications. It is shown that with a total complexity of less than three times that of the basic Viterbi decoder, concatenated coding improves a constraint length 8 rate 1/3 Viterbi decoding system by 1.1 and 2.6 dB at bit error probabilities of 0.0001 and one hundred millionth, respectively. With a somewhat greater total complexity, the hybrid coding system is shown to obtain a 0.9-dB computational performance improvement over the basic rate 1/3 sequential decoding system. Although substantial, these complexities are much less than those required to achieve the same performances with more complex Viterbi or sequential decoder systems.
Improved coverage of cDNA-AFLP by sequential digestion of immobilized cDNA.
Weiberg, Arne; Pöhler, Dirk; Morgenstern, Burkhard; Karlovsky, Petr
2008-10-13
cDNA-AFLP is a transcriptomics technique which does not require prior sequence information and can therefore be used as a gene discovery tool. The method is based on selective amplification of cDNA fragments generated by restriction endonucleases, electrophoretic separation of the products and comparison of the band patterns between treated samples and controls. Unequal distribution of restriction sites used to generate cDNA fragments negatively affects the performance of cDNA-AFLP. Some transcripts are represented by more than one fragment while other escape detection, causing redundancy and reducing the coverage of the analysis, respectively. With the goal of improving the coverage of cDNA-AFLP without increasing its redundancy, we designed a modified cDNA-AFLP protocol. Immobilized cDNA is sequentially digested with several restriction endonucleases and the released DNA fragments are collected in mutually exclusive pools. To investigate the performance of the protocol, software tool MECS (Multiple Enzyme cDNA-AFLP Simulation) was written in Perl. cDNA-AFLP protocols described in the literature and the new sequential digestion protocol were simulated on sets of cDNA sequences from mouse, human and Arabidopsis thaliana. The redundancy and coverage, the total number of PCR reactions, and the average fragment length were calculated for each protocol and cDNA set. Simulation revealed that sequential digestion of immobilized cDNA followed by the partitioning of released fragments into mutually exclusive pools outperformed other cDNA-AFLP protocols in terms of coverage, redundancy, fragment length, and the total number of PCRs. Primers generating 30 to 70 amplicons per PCR provided the highest fraction of electrophoretically distinguishable fragments suitable for normalization. For A. thaliana, human and mice transcriptome, the use of two marking enzymes and three sequentially applied releasing enzymes for each of the marking enzymes is recommended.
Vojtechova, Iveta; Petrasek, Tomas; Hatalova, Hana; Pistikova, Adela; Vales, Karel; Stuchlik, Ales
2016-05-15
The prevention of engram interference, pattern separation, flexibility, cognitive coordination and spatial navigation are usually studied separately at the behavioral level. Impairment in executive functions is often observed in patients suffering from schizophrenia. We have designed a protocol for assessing these functions all together as behavioral separation. This protocol is based on alternated or sequential training in two tasks testing different hippocampal functions (the Morris water maze and active place avoidance), and alternated or sequential training in two similar environments of the active place avoidance task. In Experiment 1, we tested, in adult rats, whether the performance in two different spatial tasks was affected by their order in sequential learning, or by their day-to-day alternation. In Experiment 2, rats learned to solve the active place avoidance task in two environments either alternately or sequentially. We found that rats are able to acquire both tasks and to discriminate both similar contexts without obvious problems regardless of the order or the alternation. We used two groups of rats, controls and a rat model of psychosis induced by a subchronic intraperitoneal application of 0.08mg/kg of dizocilpine (MK-801), a non-competitive antagonist of NMDA receptors. Dizocilpine had no selective effect on parallel/sequential learning of tasks/contexts. However, it caused hyperlocomotion and a significant deficit in learning in the active place avoidance task regardless of the task alternation. Cognitive coordination tested by this task is probably more sensitive to dizocilpine than spatial orientation because no hyperactivity or learning impairment was observed in the Morris water maze. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Man, Jun; Zhang, Jiangjiang; Li, Weixuan
2016-10-01
The ensemble Kalman filter (EnKF) has been widely used in parameter estimation for hydrological models. The focus of most previous studies was to develop more efficient analysis (estimation) algorithms. On the other hand, it is intuitively understandable that a well-designed sampling (data-collection) strategy should provide more informative measurements and subsequently improve the parameter estimation. In this work, a Sequential Ensemble-based Optimal Design (SEOD) method, coupled with EnKF, information theory and sequential optimal design, is proposed to improve the performance of parameter estimation. Based on the first-order and second-order statistics, different information metrics including the Shannon entropy difference (SD), degrees ofmore » freedom for signal (DFS) and relative entropy (RE) are used to design the optimal sampling strategy, respectively. The effectiveness of the proposed method is illustrated by synthetic one-dimensional and two-dimensional unsaturated flow case studies. It is shown that the designed sampling strategies can provide more accurate parameter estimation and state prediction compared with conventional sampling strategies. Optimal sampling designs based on various information metrics perform similarly in our cases. The effect of ensemble size on the optimal design is also investigated. Overall, larger ensemble size improves the parameter estimation and convergence of optimal sampling strategy. Although the proposed method is applied to unsaturated flow problems in this study, it can be equally applied in any other hydrological problems.« less
Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki
2013-06-07
This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.
NASA Astrophysics Data System (ADS)
Gonderman, S.; Tripathi, J. K.; Sizyuk, T.; Hassanein, A.
2017-08-01
Tungsten (W) has been selected as the divertor material in ITER based on its promising thermal and mechanical properties. Despite these advantages, continued investigation has revealed W to undergo extreme surface morphology evolution in response to relevant fusion operating conditions. These complications spur the need for further exploration of W and other innovative plasma facing components (PFCs) for future fusion devices. Recent literature has shown that alloying of W with other refractory metals, such as tantalum (Ta), results in the enhancement of key PFC properties including, but not limited to, ductility, hydrogen isotope retention, and helium ion (He+) radiation tolerance. In the present study, pure W and W-Ta alloys are exposed to simultaneous and sequential low energy, He+ and deuterium (D+) ion beam irradiations at high (1223 K) and low (523 K) temperatures. The goal of this study is to cultivate a complete understanding of the synergistic effects induced by dual and sequential ion irradiation on W and W-Ta alloy surface morphology evolution. For the dual ion beam experiments, W and W-Ta samples were subjected to four different He+: D+ ion ratios (100% He+, 60% D+ + 40% He+, 90% D+ + 10% He+ and 100% D+) having a total constant He+ fluence of 6 × 1024 ion m-2. The W and W-Ta samples both exhibit the expected damaged surfaces under the 100% He+ irradiation, but as the ratio of D+/He+ ions increases there is a clear suppression of the surface morphology at high temperatures. This observation is supported by the sequential experiments, which show a similar suppression of surface morphology when W and W-Ta samples are first exposed to low energy He+ irradiation and then exposed to subsequent low energy D+ irradiation at high temperatures. Interestingly, this morphology suppression is not observed at low temperatures, implying there is a D-W interaction mechanism which is dependent on temperature that is driving the suppression of the microstructure evolution in both the pure W and W-Ta alloys. Minor irradiation tolerance enhancement in the performance of the W-Ta samples is also observed.
de Jong, Britt G; IJspeert, Hanna; Marques, Lemelinda; van der Burg, Mirjam; van Dongen, Jacques Jm; Loos, Bruno G; van Zelm, Menno C
2017-10-01
The mechanisms involved in sequential immunoglobulin G (IgG) class switching are still largely unknown. Sequential IG class switching is linked to higher levels of somatic hypermutation (SHM) in vivo, but it remains unclear if these are generated temporally during an immune response or upon activation in a secondary response. We here aimed to uncouple these processes and to distinguish memory B cells from primary and secondary immune responses. SHM levels and IgG subclasses were studied with 454 pyrosequencing on blood mononuclear cells from young children and adults as models for primary and secondary immunological memory. Additional sequencing and detailed immunophenotyping with IgG subclass-specific antibodies was performed on purified IgG + memory B-cell subsets. In both children and adults, SHM levels were higher in transcripts involving more downstream-located IGHG genes (esp. IGHG2 and IGHG4). In adults, SHM levels were significantly higher than in children, and downstream IGHG genes were more frequently utilized. This was associated with increased frequencies of CD27 + IgG + memory B cells, which contained higher levels of SHM, more IGHG2 usage, and higher expression levels of activation markers than CD27 - IgG + memory B cells. We conclude that secondary immunological memory accumulates with age and these memory B cells express CD27, high levels of activation markers, and carry high SHM levels and frequent usage of IGHG2. These new insights contribute to our understanding of sequential IgG subclass switching and show a potential relevance of using serum IgG2 levels or numbers of IgG2-expressing B cells as markers for efficient generation of memory responses.
Sequential data access with Oracle and Hadoop: a performance comparison
NASA Astrophysics Data System (ADS)
Baranowski, Zbigniew; Canali, Luca; Grancher, Eric
2014-06-01
The Hadoop framework has proven to be an effective and popular approach for dealing with "Big Data" and, thanks to its scaling ability and optimised storage access, Hadoop Distributed File System-based projects such as MapReduce or HBase are seen as candidates to replace traditional relational database management systems whenever scalable speed of data processing is a priority. But do these projects deliver in practice? Does migrating to Hadoop's "shared nothing" architecture really improve data access throughput? And, if so, at what cost? Authors answer these questions-addressing cost/performance as well as raw performance- based on a performance comparison between an Oracle-based relational database and Hadoop's distributed solutions like MapReduce or HBase for sequential data access. A key feature of our approach is the use of an unbiased data model as certain data models can significantly favour one of the technologies tested.
Tang, Ning; Zhang, Qianqian; Fang, Shu; Han, Xiao; Wang, Zhehai
2017-01-01
Treatment of non-small-cell lung cancer (NSCLC) with wild-type epidermal growth factor receptor (EGFR) is still a challenge. This study explored antitumor activity of high-dose icotinib (an EGFR tyrosine kinase inhibitor) plus sequential docetaxel against wild-type EGFR NSCLC cells-generated nude mouse xenografts. Nude mice were subcutaneously injected with wild-type EGFR NSCLC A549 cells and divided into different groups for 3-week treatment. Tumor xenograft volumes were monitored and recorded, and at the end of experiments, tumor xenografts were removed for Western blot and immunohistochemical analyses. Compared to control groups (negative control, regular-dose icotinib [IcoR], high-dose icotinib [IcoH], and docetaxel [DTX]) and regular icotinib dose (60 mg/kg) with docetaxel, treatment of mice with a high-dose (1200 mg/kg) of icotinib plus sequential docetaxel for 3 weeks (IcoH-DTX) had an additive effect on suppression of tumor xenograft size and volume (P < 0.05). Icotinib-containing treatments markedly reduced phosphorylation of EGFR, mitogen activated protein kinase (MAPK), and protein kinase B (Akt), but only the high-dose icotinib-containing treatments showed an additive effect on CD34 inhibition (P < 0.05), an indication of reduced microvessel density in tumor xenografts. Moreover, high-dose icotinib plus docetaxel had a similar effect on mouse weight loss (a common way to measure adverse reactions in mice), compared to the other treatment combinations. The study indicate that the high dose of icotinib plus sequential docetaxel (IcoH-DTX) have an additive effect on suppressing the growth of wild-type EGFR NSCLC cell nude mouse xenografts, possibly through microvessel density reduction. Future clinical trials are needed to confirm the findings of this study. PMID:27852073
Comparative Implementation of High Performance Computing for Power System Dynamic Simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Shuangshuang; Huang, Zhenyu; Diao, Ruisheng
Dynamic simulation for transient stability assessment is one of the most important, but intensive, computations for power system planning and operation. Present commercial software is mainly designed for sequential computation to run a single simulation, which is very time consuming with a single processer. The application of High Performance Computing (HPC) to dynamic simulations is very promising in accelerating the computing process by parallelizing its kernel algorithms while maintaining the same level of computation accuracy. This paper describes the comparative implementation of four parallel dynamic simulation schemes in two state-of-the-art HPC environments: Message Passing Interface (MPI) and Open Multi-Processing (OpenMP).more » These implementations serve to match the application with dedicated multi-processor computing hardware and maximize the utilization and benefits of HPC during the development process.« less
Fang, Yongjin; Yu, Xin-Yao; Lou, Xiong Wen David
2018-04-06
Electrode materials based on electrochemical conversion reactions have received considerable interest for high capacity anodes of sodium-ion batteries. However, their practical application is greatly hindered by the poor rate capability and rapid capacity fading. Tuning the structure at nanoscale and increasing the conductivity of these anode materials are two effective strategies to address these issues. Herein, a two-step ion-exchange method is developed to synthesize hierarchical Cu-doped CoSe 2 microboxes assembled by ultrathin nanosheets using Co-Co Prussian blue analogue microcubes as the starting material. Benefitting from the structural and compositional advantages, these Cu-doped CoSe 2 microboxes with improved conductivity exhibit enhanced sodium storage properties in terms of good rate capability and excellent cycling performance. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Ibrahim, Bashirah; Ding, Lin; Heckler, Andrew F.; White, Daniel R.; Badeau, Ryan
2017-12-01
We examine students' mathematical performance on quantitative "synthesis problems" with varying mathematical complexity. Synthesis problems are tasks comprising multiple concepts typically taught in different chapters. Mathematical performance refers to the formulation, combination, and simplification of equations. Generally speaking, formulation and combination of equations require conceptual reasoning; simplification of equations requires manipulation of equations as computational tools. Mathematical complexity is operationally defined by the number and the type of equations to be manipulated concurrently due to the number of unknowns in each equation. We use two types of synthesis problems, namely, sequential and simultaneous tasks. Sequential synthesis tasks require a chronological application of pertinent concepts, and simultaneous synthesis tasks require a concurrent application of the pertinent concepts. A total of 179 physics major students from a second year mechanics course participated in the study. Data were collected from written tasks and individual interviews. Results show that mathematical complexity negatively influences the students' mathematical performance on both types of synthesis problems. However, for the sequential synthesis tasks, it interferes only with the students' simplification of equations. For the simultaneous synthesis tasks, mathematical complexity additionally impedes the students' formulation and combination of equations. Several reasons may explain this difference, including the students' different approaches to the two types of synthesis problems, cognitive load, and the variation of mathematical complexity within each synthesis type.
Expert anticipatory skill in striking sports: a review and a model.
Müller, Sean; Abernethy, Bruce
2012-06-01
Expert performers in striking sports can hit objects moving at high speed with incredible precision. Exceptionally well developed anticipation skills are necessary to cope with the severe constraints on interception. In this papr we provide a review of the empirical evidence regarding expert interception in striking sports and propose a preliminary model of expert anticipation. Central to the review and the model is the notion that the visual information used to guide the sequential phases of the striking action is systematically different between experts and nonexperts. Knowing the factors that contribute to expert anticipation, and how anticipation may guide skilled performance in striking sports, has practical implications for assessment and training across skill levels.
NASA Astrophysics Data System (ADS)
Ginosar, Ran; Aviely, Peleg; Liran, Tuvia; Alon, Dov; Dobkin, Reuven; Goldberg, Michael
2013-08-01
RC64, a novel 64-core many-core signal processing chip targets DSP performance of 12.8 GIPS, 100 GOPS and 12.8 single precision GFLOS while dissipating only 3 Watts. RC64 employs advanced DSP cores, a multi-bank shared memory and a hardware scheduler, supports DDR2 memory and communicates over five proprietary 6.4 Gbps channels. The programming model employs sequential fine-grain tasks and a separate task map to define task dependencies. RC64 is implemented as a 200 MHz ASIC on Tower 130nm CMOS technology, assembled in hermetically sealed ceramic QFP package and qualified to the highest space standards.
A sequential adaptation technique and its application to the Mark 12 IFF system
NASA Astrophysics Data System (ADS)
Bailey, John S.; Mallett, John D.; Sheppard, Duane J.; Warner, F. Neal; Adams, Robert
1986-07-01
Sequential adaptation uses only two sets of receivers, correlators, and A/D converters which are time multiplexed to effect spatial adaptation in a system with (N) adaptive degrees of freedom. This technique can substantially reduce the hardware cost over what is realizable in a parallel architecture. A three channel L-band version of the sequential adapter was built and tested for use with the MARK XII IFF (identify friend or foe) system. In this system the sequentially determined adaptive weights were obtained digitally but implemented at RF. As a result, many of the post RF hardware induced sources of error that normally limit cancellation, such as receiver mismatch, are removed by the feedback property. The result is a system that can yield high levels of cancellation and be readily retrofitted to currently fielded equipment.
Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.
Nagatsu, T; Oka, K; Kato, T
1979-07-21
A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.
Prediction of tumor differentiation using sequential PET/CT and MRI in patients with breast cancer.
Choi, Joon Ho; Lim, Ilhan; Noh, Woo Chul; Kim, Hyun-Ah; Seong, Min-Ki; Jang, Seonah; Seol, Hyesil; Moon, Hansol; Byun, Byung Hyun; Kim, Byung Il; Choi, Chang Woon; Lim, Sang Moo
2018-05-23
The aim of this study is to assess tumor differentiation using parameters from sequential positron emission tomography/computed tomography (PET/CT) and magnetic resonance imaging (MRI) in patients with breast cancer. This retrospective study included 78 patients with breast cancer. All patients underwent sequential PET/CT and MRI. For fluorodeoxyglucose (FDG)-PET image analysis, the maximum standardized uptake value (SUV max ) of FDG was assessed at both 1 and 2 h and metabolic tumor volume (MTV) and total lesion glycolysis (TLG). The kinetic analysis of dynamic contrast-enhanced MRI parameters was performed using dynamic enhancement curves. We assessed diffusion-weighted imaging (DWI)-MRI parameters regarding apparent diffusion coefficient (ADC) values. Histologic grades 1 and 2 were classified as low-grade, and grade 3 as high-grade tumor. Forty-five lesions of 78 patients were classified as histologic grade 3, while 26 and 7 lesions were grade 2 and grade 1, respectively. Patients with high-grade tumors showed significantly lower ADC-mean values than patients with low-grade tumors (0.99 ± 0.19 vs.1.12 ± 0.32, p = 0.007). With respect to SUV max 1, MTV2.5, and TLG2.5, patients with high-grade tumors showed higher values than patients with low-grade tumors: SUV max 1 (7.92 ± 4.5 vs.6.19 ± 3.05, p = 0.099), MTV2.5 (7.90 ± 9.32 vs.4.38 ± 5.10, p = 0.095), and TLG2.5 (40.83 ± 59.17 vs.19.66 ± 26.08, p = 0.082). However, other parameters did not reveal significant differences between low-grade and high-grade malignancies. In receiver-operating characteristic (ROC) curve analysis, ADC-mean values showed the highest area under the curve of 0.681 (95%CI 0.566-0.782) for assessing high-grade malignancy. Lower ADC-mean values may predict the poor differentiation of breast cancer among diverse PET-MRI functional parameters.
NASA Technical Reports Server (NTRS)
Wheeler, D. B.
1978-01-01
Engine performance data, combustion gas thermodynamic properties, and turbine gas parameters were determined for various high power cycle engine configurations derived from the space shuttle main engine that will allow sequential burning of LOX/hydrocarbon and LOX/hydrogen fuels. Both stage combustion and gas generator pump power cycles were considered. Engine concepts were formulated for LOX/RP-1, LOX/CH4, and LOX/C3H8 propellants. Flowrates and operating conditions were established for this initial set of engine systems, and the adaptability of the major components of shuttle main engine was investigated.
Traveling-wave tube reliability estimates, life tests, and space flight experience
NASA Technical Reports Server (NTRS)
Lalli, V. R.; Speck, C. E.
1977-01-01
Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.
Anatomic optical coherence tomography for dynamic imaging of the upper airway
NASA Astrophysics Data System (ADS)
Bu, Ruofei; Balakrishnan, Santosh; Iftimia, Nicusor; Price, Hillel; Zdanski, Carlton; Oldenburg, Amy L.
2017-03-01
To aid in diagnosis and treatment of upper airway obstructive disorders (UAOD), we propose anatomic Optical Coherence Tomography (aOCT) for endoscopic imaging of the upper airway lumen with high speed and resolution. aOCT and CT scans are performed sequentially on in vivo swine to compare dynamic airway imaging data. The aOCT system is capable of capturing the dynamic deformation of the airway during respiration. This may lead to methods for airway elastography and aid in our understanding of dynamic collapse in UAOD.
Alexiou, George A; Stefanaki, Kalliopi; Vartholomatos, George; Sfakianos, George; Prodromou, Neofytos; Moschovi, Maria
2013-12-01
Embryonal tumor with abundant neuropil and true rosettes has been recently defined as a distinct central nervous system embryonal neoplasm, although it was initially regarded as a subtype of central nervous system primitive neuroectodermal tumor. To date 70 cases have been reported. We have performed a literature review and we present 2 new cases. Analysis of the reported data revealed that radiotherapy, tumor excision and high-dose adjuvant chemotherapy with sequential autologous hematopoietic stem cell rescue have a prognostic significance.
Vuckovic, Anita; Kwantes, Peter J; Neal, Andrew
2013-09-01
Research has identified a wide range of factors that influence performance in relative judgment tasks. However, the findings from this research have been inconsistent. Studies have varied with respect to the identification of causal variables and the perceptual and decision-making mechanisms underlying performance. Drawing on the ecological rationality approach, we present a theory of the judgment and decision-making processes involved in a relative judgment task that explains how people judge a stimulus and adapt their decision process to accommodate their own uncertainty associated with those judgments. Undergraduate participants performed a simulated air traffic control conflict detection task. Across two experiments, we systematically manipulated variables known to affect performance. In the first experiment, we manipulated the relative distances of aircraft to a common destination while holding aircraft speeds constant. In a follow-up experiment, we introduced a direct manipulation of relative speed. We then fit a sequential sampling model to the data, and used the best fitting parameters to infer the decision-making processes responsible for performance. Findings were consistent with the theory that people adapt to their own uncertainty by adjusting their criterion and the amount of time they take to collect evidence in order to make a more accurate decision. From a practical perspective, the paper demonstrates that one can use a sequential sampling model to understand performance in a dynamic environment, allowing one to make sense of and interpret complex patterns of empirical findings that would otherwise be difficult to interpret using standard statistical analyses. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Analysis of scalability of high-performance 3D image processing platform for virtual colonoscopy
NASA Astrophysics Data System (ADS)
Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli
2014-03-01
One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. For this purpose, we previously developed a software platform for high-performance 3D medical image processing, called HPC 3D-MIP platform, which employs increasingly available and affordable commodity computing systems such as the multicore, cluster, and cloud computing systems. To achieve scalable high-performance computing, the platform employed size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D-MIP algorithms, supported task scheduling for efficient load distribution and balancing, and consisted of a layered parallel software libraries that allow image processing applications to share the common functionalities. We evaluated the performance of the HPC 3D-MIP platform by applying it to computationally intensive processes in virtual colonoscopy. Experimental results showed a 12-fold performance improvement on a workstation with 12-core CPUs over the original sequential implementation of the processes, indicating the efficiency of the platform. Analysis of performance scalability based on the Amdahl's law for symmetric multicore chips showed the potential of a high performance scalability of the HPC 3DMIP platform when a larger number of cores is available.
Escande, Vincent; Renard, Brice-Loïc; Grison, Claude
2015-04-01
Among the phytotechnologies used for the reclamation of degraded mining sites, phytoextraction aims to diminish the concentration of polluting elements in contaminated soils. However, the biomass resulting from the phytoextraction processes (highly enriched in polluting elements) is too often considered as a problematic waste. The manganese-enriched biomass derived from native Mn-hyperaccumulating plants of New Caledonia was presented here as a valuable source of metallic elements of high interest in chemical catalysis. The preparation of the catalyst Eco-Mn1 and reagent Eco-Mn2 derived from Grevillea exul exul and Grevillea exul rubiginosa was investigated. Their unusual polymetallic compositions allowed to explore new reactivity of low oxidative state of manganese-Mn(II) for Eco-Mn1 and Mn(IV) for Eco-Mn2. Eco-Mn1 was used as a Lewis acid to catalyze the acetalization/elimination of aldehydes into enol ethers with high yields; a new green and stereoselective synthesis of (-)-isopulegol via the carbonyl-ene cyclization of (+)-citronellal was also performed with Eco-Mn1. Eco-Mn2 was used as a mild oxidative reagent and controlled the oxidation of aliphatic alcohols into aldehydes with quantitative yields. Oxidative cleavage was interestingly noticed when Eco-Mn2 was used in the presence of a polyol. Eco-Mn2 allowed direct oxidative iodination of ketones without using iodine, which is strongly discouraged by new environmental legislations. Finally, the combination of the properties in the Eco-Mn catalysts and reagents gave them an unprecedented potential to perform sequential tandem oxidation processes through new green syntheses of p-cymene from (-)-isopulegol and (+)-citronellal; and a new green synthesis of functionalized pyridines by in situ oxidation of 1,4-dihydropyridines.
Abahmane, Lahbib; Köhler, J Michael; Gross, G Alexander
2011-03-01
The alkyne, aldehyde, amine A(3)-coupling reaction, a traditional multicomponent reaction (MCR), has been investigated as a two-step flow process. The implicated aminoalkylation reaction of phenylacetylene with appropriate aldimine intermediates was catalyzed by gold nanoparticles impregnated on alumina. The aldimine formation was catalyzed by Montmorillonite K10 beforehand. The performance of the process has been investigated with respect to different reaction regimes. Usually, the A(3)-multicomponent reaction is performed as a "one-pot" process. Diversity-oriented syntheses using MCRs often have the shortcoming that only low selectivity and low yields are achieved. We have used a flow-chemistry approach to perform the A(3)-MCR in a sequential manner. In this way, the reaction performance was significantly enhanced in terms of shortened reaction time, and the desired propargylamines were obtained in high yields. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rochau, Ursula; Sroczynski, Gaby; Wolf, Dominik; Schmidt, Stefan; Jahn, Beate; Kluibenschaedl, Martina; Conrads-Frank, Annette; Stenehjem, David; Brixner, Diana; Radich, Jerald; Gastl, Günther; Siebert, Uwe
2015-01-01
Several tyrosine kinase inhibitors (TKIs) are approved for chronic myeloid leukemia (CML) therapy. We evaluated the long-term cost-effectiveness of seven sequential therapy regimens for CML in Austria. A cost-effectiveness analysis was performed using a state-transition Markov model. As model parameters, we used published trial data, clinical, epidemiological and economic data from the Austrian CML registry and national databases. We performed a cohort simulation over a life-long time-horizon from a societal perspective. Nilotinib without second-line TKI yielded an incremental cost-utility ratio of 121,400 €/quality-adjusted life year (QALY) compared to imatinib without second-line TKI after imatinib failure. Imatinib followed by nilotinib after failure resulted in 131,100 €/QALY compared to nilotinib without second-line TKI. Nilotinib followed by dasatinib yielded 152,400 €/QALY compared to imatinib followed by nilotinib after failure. Remaining strategies were dominated. The sequential application of TKIs is standard-of-care, and thus, our analysis points toward imatinib followed by nilotinib as the most cost-effective strategy.
Spiegelhalter, David; Grigg, Olivia; Kinsman, Robin; Treasure, Tom
2003-02-01
To investigate the use of the risk-adjusted sequential probability ratio test in monitoring the cumulative occurrence of adverse clinical outcomes. Retrospective analysis of three longitudinal datasets. Patients aged 65 years and over under the care of Harold Shipman between 1979 and 1997, patients under 1 year of age undergoing paediatric heart surgery in Bristol Royal Infirmary between 1984 and 1995, adult patients receiving cardiac surgery from a team of cardiac surgeons in London,UK. Annual and 30-day mortality rates. Using reasonable boundaries, the procedure could have indicated an 'alarm' in Bristol after publication of the 1991 Cardiac Surgical Register, and in 1985 or 1997 for Harold Shipman depending on the data source and the comparator. The cardiac surgeons showed no significant deviation from expected performance. The risk-adjusted sequential probability test is simple to implement, can be applied in a variety of contexts, and might have been useful to detect specific instances of past divergent performance. The use of this and related techniques deserves further attention in the context of prospectively monitoring adverse clinical outcomes.
Sequential analysis in neonatal research-systematic review.
Lava, Sebastiano A G; Elie, Valéry; Ha, Phuong Thi Viet; Jacqz-Aigrain, Evelyne
2018-05-01
As more new drugs are discovered, traditional designs come at their limits. Ten years after the adoption of the European Paediatric Regulation, we performed a systematic review on the US National Library of Medicine and Excerpta Medica database of sequential trials involving newborns. Out of 326 identified scientific reports, 21 trials were included. They enrolled 2832 patients, of whom 2099 were analyzed: the median number of neonates included per trial was 48 (IQR 22-87), median gestational age was 28.7 (IQR 27.9-30.9) weeks. Eighteen trials used sequential techniques to determine sample size, while 3 used continual reassessment methods for dose-finding. In 16 studies reporting sufficient data, the sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674) with respect to a traditional trial. When the number of neonates finally included in the analysis was considered, the difference became significant: 35 (57%) patients (IQR 10 to 136.5, p = 0.0033). Sequential trial designs have not been frequently used in Neonatology. They might potentially be able to reduce the number of patients in drug trials, although this is not always the case. What is known: • In evaluating rare diseases in fragile populations, traditional designs come at their limits. About 20% of pediatric trials are discontinued, mainly because of recruitment problems. What is new: • Sequential trials involving newborns were infrequently used and only a few (n = 21) are available for analysis. • The sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674).
Cressman, Erik N K; Shenoi, Mithun M; Edelman, Theresa L; Geeslin, Matthew G; Hennings, Leah J; Zhang, Yan; Iaizzo, Paul A; Bischof, John C
2012-01-01
To investigate simultaneous and sequential injection thermochemical ablation in a porcine model, and compare them to sham and acid-only ablation. This IACUC-approved study involved 11 pigs in an acute setting. Ultrasound was used to guide placement of a thermocouple probe and coaxial device designed for thermochemical ablation. Solutions of 10 M acetic acid and NaOH were used in the study. Four injections per pig were performed in identical order at a total rate of 4 mL/min: saline sham, simultaneous, sequential, and acid only. Volume and sphericity of zones of coagulation were measured. Fixed specimens were examined by H&E stain. Average coagulation volumes were 11.2 mL (simultaneous), 19.0 mL (sequential) and 4.4 mL (acid). The highest temperature, 81.3°C, was obtained with simultaneous injection. Average temperatures were 61.1°C (simultaneous), 47.7°C (sequential) and 39.5°C (acid only). Sphericity coefficients (0.83-0.89) had no statistically significant difference among conditions. Thermochemical ablation produced substantial volumes of coagulated tissues relative to the amounts of reagents injected, considerably greater than acid alone in either technique employed. The largest volumes were obtained with sequential injection, yet this came at a price in one case of cardiac arrest. Simultaneous injection yielded the highest recorded temperatures and may be tolerated as well as or better than acid injection alone. Although this pilot study did not show a clear advantage for either sequential or simultaneous methods, the results indicate that thermochemical ablation is attractive for further investigation with regard to both safety and efficacy.
Fingeret, Abbey L; Arnell, Tracey; McNelis, John; Statter, Mindy; Dresner, Lisa; Widmann, Warren
We sought to determine whether sequential participation in a multi-institutional mock oral examination affected the likelihood of passing the American Board of Surgery Certifying Examination (ABSCE) in first attempt. Residents from 3 academic medical centers were able to participate in a regional mock oral examination in the fall and spring of their fourth and fifth postgraduate year from 2011 to 2014. Candidate׳s highest composite score of all mock orals attempts was classified as risk for failure, intermediate, or likely to pass. Factors including United States Medical Licensing Examination steps 1, 2, and 3, number of cases logged, American Board of Surgery In-Training Examination performance, American Board of Surgery Qualifying Examination (ABSQE) performance, number of attempts, and performance in the mock orals were assessed to determine factors predictive of passing the ABSCE. A total of 128 mock oral examinations were administered to 88 (71%) of 124 eligible residents. The overall first-time pass rate for the ABSCE was 82%. There was no difference in pass rates between participants and nonparticipants. Of them, 16 (18%) residents were classified as at risk, 47 (53%) as intermediate, and 25 (29%) as likely to pass. ABSCE pass rate for each group was as follows: 36% for at risk, 84% for intermediate, and 96% for likely pass. The following 4 factors were associated with first-time passing of ABSCE on bivariate analysis: mock orals participation in postgraduate year 4 (p = 0.05), sequential participation in mock orals (p = 0.03), ABSQE performance (p = 0.01), and best performance on mock orals (p = 0.001). In multivariable logistic regression, the following 3 factors remained associated with ABSCE passing: ABSQE performance, odds ratio (OR) = 2.9 (95% CI: 1.3-6.1); mock orals best performance, OR = 1.7 (1.2-2.4); and participation in multiple mock oral examinations, OR = 1.4 (1.1-2.7). Performance on a multi-institutional mock oral examination can identify residents at risk for failure of the ABSCE. Sequential participation in mock oral examinations is associated with improved ABSCE first-time pass rate. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Grafe, Victor G.; Hoch, James E.
1993-01-01
A sequencing and data fanout mechanism is provided for a dataflow processor is activated by an input token which causes a sequence of operations to occur by initiating a first instruction to act on data contained within the token and then executing a sequential thread of instructions identified by either a repeat count and an offset within the token, or by an offset within each preceding instruction.
Sequential Events Control System (SECS) Overview
NASA Technical Reports Server (NTRS)
Interbartolo, Michael
2009-01-01
This slide presentation will cover the Sequential Events Control System (SECS), which is the Apollo spacecraft subsystem that controls the automatically sequenced functions during the mission and during any a borts that could be performed. Included in this presentation are its general architecture, its integration into and use of the spacecraft' s other systems, and details on the functions it is responsible for c ontrolling during the mission. The objectives are to describe the system's architecture, the major components in the system, and the major system functions.
Tomei, M Concetta; Carozza, Nicola Antonello
2015-05-01
Sequential anaerobic-aerobic digestion has been demonstrated as a promising alternative for enhanced sludge stabilization. In this paper, a feasibility study of the sequential digestion applied to real waste activated sludge (WAS) and mixed sludge is presented. Process performance is evaluated in terms of total solid (TS) and volatile solid (VS) removal, biogas production, and dewaterability trend in the anaerobic and double-stage digested sludge. In the proposed digestion lay out, the aerobic stage was operated with intermittent aeration to reduce the nitrogen load recycled to the wastewater treatment plant (WWTP). Experimental results showed a very good performance of the sequential digestion process for both waste and mixed sludge, even if, given its better digestibility, higher efficiencies are observed for mixed sludge. VS removal efficiencies in the anaerobic stage were 48 and 50% for waste and mixed sludge, respectively, while a significant additional improvement of the VS removal of 25% for WAS and 45% for mixed sludge has been obtained in the aerobic stage. The post-aerobic stage, operated with intermittent aeration, was also efficient in nitrogen removal, providing a significant decrease of the nitrogen content in the supernatant: nitrification efficiencies of 90 and 97% and denitrification efficiencies of 62 and 70% have been obtained for secondary and mixed sludges, respectively. A positive effect due to the aerobic stage was also observed on the sludge dewaterability in both cases. Biogas production, expressed as Nm(3)/(kgVSdestroyed), was 0.54 for waste and 0.82 for mixed sludge and is in the range of values reported in the literature in spite of the low anaerobic sludge retention time of 15 days.
Spinal cord ischemia after simultaneous and sequential treatment of multilevel aortic disease.
Piffaretti, Gabriele; Bonardelli, Stefano; Bellosta, Raffaello; Mariscalco, Giovanni; Lomazzi, Chiara; Tolenaar, Jip L; Zanotti, Camilla; Guadrini, Cristina; Sarcina, Antonio; Castelli, Patrizio; Trimarchi, Santi
2014-10-01
The aim of the present study is to report a risk analysis for spinal cord injury in a recent cohort of patients with simultaneous and sequential treatment of multilevel aortic disease. We performed a multicenter study with a retrospective data analysis. Simultaneous treatment refers to descending thoracic and infrarenal aortic lesions treated during the same operation, and sequential treatment refers to separate operations. All descending replacements were managed with endovascular repair. Of 4320 patients, multilevel aortic disease was detected in 77 (1.8%). Simultaneous repair was performed in 32 patients (41.5%), and a sequential repair was performed in 45 patients (58.4%). Postoperative spinal cord injury developed in 6 patients (7.8%). At multivariable analysis, the distance of the distal aortic neck from the celiac trunk was the only independent predictor of postoperative spinal cord injury (odds ratio, 0.75; 95% confidence interval, 0.56-0.99; P=.046); open surgical repair of the abdominal aortic disease was associated with a higher risk of spinal cord injury but did not reach statistical significance (odds ratio, 0.16; 95% confidence interval, 0.02-1.06; P=.057). Actuarial survival estimates at 1, 2, and 5 years after the procedure were 80%±5%, 68%±6%, and 63%±7%, respectively. Spinal cord injury did not impair survival (P=.885). In our experience, the risk of spinal cord injury is still substantial at 8% in patients with multilevel aortic disease. The distance of the distal landing zone from the celiac trunk is a significant predictor of spinal cord ischemia. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Pi, Fengmei; Zhao, Zhengyi; Chelikani, Venkata; Yoder, Kristine; Kvaratskhelia, Mamuka
2016-01-01
The intracellular parasitic nature of viruses and the emergence of antiviral drug resistance necessitate the development of new potent antiviral drugs. Recently, a method for developing potent inhibitory drugs by targeting biological machines with high stoichiometry and a sequential-action mechanism was described. Inspired by this finding, we reviewed the development of antiviral drugs targeting viral DNA-packaging motors. Inhibiting multisubunit targets with sequential actions resembles breaking one bulb in a series of Christmas lights, which turns off the entire string. Indeed, studies on viral DNA packaging might lead to the development of new antiviral drugs. Recent elucidation of the mechanism of the viral double-stranded DNA (dsDNA)-packaging motor with sequential one-way revolving motion will promote the development of potent antiviral drugs with high specificity and efficiency. Traditionally, biomotors have been classified into two categories: linear and rotation motors. Recently discovered was a third type of biomotor, including the viral DNA-packaging motor, beside the bacterial DNA translocases, that uses a revolving mechanism without rotation. By analogy, rotation resembles the Earth's rotation on its own axis, while revolving resembles the Earth's revolving around the Sun (see animations at http://rnanano.osu.edu/movie.html). Herein, we review the structures of viral dsDNA-packaging motors, the stoichiometries of motor components, and the motion mechanisms of the motors. All viral dsDNA-packaging motors, including those of dsDNA/dsRNA bacteriophages, adenoviruses, poxviruses, herpesviruses, mimiviruses, megaviruses, pandoraviruses, and pithoviruses, contain a high-stoichiometry machine composed of multiple components that work cooperatively and sequentially. Thus, it is an ideal target for potent drug development based on the power function of the stoichiometries of target complexes that work sequentially. PMID:27356896
An, Liangliang; Wang, Guanhua; Jia, Hongyu; Liu, Cuiyun; Sui, Wenjie; Si, Chuanling
2017-06-01
The heterogeneity of lignin chemical structure and molecular weight results in the lignin inhomogeneous properties which also covers the antioxidant performance. In order to evaluate the effects of lignin heterogeneity on its antioxidant activity, four lignin fractions from enzymatic hydrolysis lignin were classified by sequential organic solvent extraction and further evaluated by DPPH (1,1-Diphenyl-2-Picrylhydrazyl) free radical scavenging capacity and reducing power analysis. The characterization including FTIR, 1 H NMR and GPC showed that the fractionation process could effectively separate lignin fractions with distinctly different molecular weight and weaken the heterogeneity of unfractionated lignin. The antioxidant performance comparison of lignin fractions indicated that the dichloromethane fraction (F1) with lowest molecular weight (4585g/mol) and highest total phenolics content (246.13mg GAE/g) exhibited the highest antioxidant activity whose value was close to commercial antioxidant BHT (butylated hydroxytoluene). Moreover, the relationship between the antioxidant activity and the structure of lignin was further discussed to elucidate the mechanism of antioxidant activity improvement of lignin fractionation. Consequently, this study suggested that the sequential extraction was an effective way to obtain relatively homogeneous enzymatic hydrolysis lignin fractions which showed the potential for the value-added antioxidant application. Copyright © 2017 Elsevier B.V. All rights reserved.
Direct quantum process tomography via measuring sequential weak values of incompatible observables.
Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook
2018-01-15
The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.
Wansard, Murielle; Bartolomeo, Paolo; Bastin, Christine; Segovia, Fermín; Gillet, Sophie; Duret, Christophe; Meulemans, Thierry
2015-01-01
Over the last decade, many studies have demonstrated that visuospatial working memory (VSWM) can be divided into separate subsystems dedicated to the retention of visual patterns and their serial order. Impaired VSWM has been suggested to exacerbate left visual neglect in right-brain-damaged individuals. The aim of this study was to investigate the segregation between spatial-sequential and spatial-simultaneous working memory in individuals with neglect. We demonstrated that patterns of results on these VSWM tasks can be dissociated. Spatial-simultaneous and sequential aspects of VSWM can be selectively impaired in unilateral neglect. Our results support the hypothesis of multiple VSWM subsystems, which should be taken into account to better understand neglect-related deficits.