Sample records for high-performance liquid chromatographytandem

  1. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  2. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    PubMed

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  3. Residue analysis of sixty pesticides in red swamp crayfish using QuEChERS with high-performance liquid chromatography-tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, a multi-residue analytical method using QuEChERS extraction and dispersive solid-phase extraction (d-SPE) cleanup followed by high-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) was developed for rapid determination of 60 pesticide residues in whole crayfish a...

  4. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Yu, Kate; Little, David; Plumb, Rob; Smith, Brian

    2006-01-01

    A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.

  5. Air-assisted liquid-liquid microextraction integrated with QuEChERS for determining endocrine-disrupting compounds in fish by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Luo, Zhoufei; Lu, Jing; Li, Haipu; Tu, Yi; Wan, Yuehao; Yang, Zhaoguang

    2018-09-15

    A new, sensitive, and rapid method based on the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) approach and air-assisted liquid-liquid microextraction (AALLME) technology was developed for the determination of 20 endocrine-disrupting compounds (EDCs) in fish by high-performance liquid chromatography-tandem mass spectrometry. The method first integrates AALLME into QuEChERS to achieve clean-up and enrichment of the EDCs in one step. A self-made glass tube was enfolded with plasticine to withstand the high centrifugal force. The established method was developed by optimization of the parameters. High linearities (R 2  > 0.9924) and recoveries (78.2-118.6%) at three spiked levels (5, 10, and 20 ng g -1 ), and low relative standard deviation values (1.1-14.5%) and limits of detection (0.03-0.80 ng g -1 ) were obtained. The method comparison shows that the proposed method is superior as it involves less organic solvent usage, simple operation and high efficiency. This method was successfully applied to different fishes for analyzing EDCs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Determination of type A trichothecenes in coix seed by magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes coupled with ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Dong, Maofeng; Si, Wenshuai; Wang, Weimin; Bai, Bing; Nie, Dongxia; Song, Weiguo; Zhao, Zhihui; Guo, Yirong; Han, Zheng

    2016-09-01

    Magnetic solid-phase extraction (m-SPE) is a promising sample preparation approach due to its convenience, speed, and simplicity. For the first time, a rapid and reliable m-SPE approach using magnetic multi-walled carbon nanotubes (m-MWCNTs) as the adsorbent was proposed for purification of type A trichothecenes including T-2 toxins (T2), HT-2 toxins (HT-2), diacetoxyscirpenol (DAS), and neosolaniol (NEO) in coix seed. The m-MWCNTs were synthesized by assembling the magnetic nanoparticles (Fe3O4) with MWCNTs by sonication through an aggregation wrap mechanism, and characterized by transmission electron microscope. Several key parameters affecting the performance of the procedure were extensively investigated including extraction solutions, desorption solvents, and m-MWCNT amounts. Under the optimal sample preparation conditions followed by analysis with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), high sensitivity (limit of quantification in the range of 0.3-1.5 μg kg(-1)), good linearity (R (2) > 0.99), satisfactory recovery (73.6-90.6 %), and acceptable precision (≤2.5 %) were obtained. The analytical performance of the developed method has also been successfully evaluated in real coix seed samples. Graphical Abstract Flow chart of determination of type A trichothecenes in coix seed by magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry.

  7. Determination of six parabens residues in fresh-cut vegetables using QuEChERS with multi-walled carbon nanotubes and high performance liquid chromatography-tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, an optimized QuEChERS sample preparation method was developed to analyze residues of six parabens: methyl-, ethyl-, n-propyl-, isopropyl-, n-butyl-, and isobutyl-paraben in five fresh-cut vegetables (potato, broccoli, carrot, celery and cabbage) with high performance liquid chromatogr...

  8. Investigation of the Persistence of Nerve Agent Degradation ...

    EPA Pesticide Factsheets

    Journal Article The persistence of chemical warfare nerve agent degradation analytes on surfaces is important for reasons ranging from indicating the presence of nerve agent on that surface to environmental restoration of a site after nerve agent release. This study investigates the persistence of several chemical warfare nerve agent degradation analytes on a number of indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Multiple commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces, including several porous/permeable and largely nonporous/impermeable surfaces, were investigated to determine recoveries from these indoor surface materials. Wipe extracts were analyzed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and compared with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) results. UPLC provides a sensitive separation of targeted degradation analytes in addition to being nearly four times faster than HPLC, allowing for greater throughput during a widespread release concerning large-scale contamination and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), 61-91 % for ethyl methylphosphonate (EMPA), and 60-98% for pinacolyl methylphosphona

  9. Simultaneous determination of kasugamycin and validamycin-A residues in cereals by consecutive solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Hong; Wang, Chenchen; Li, Huidong; Nie, Yan; Fang, Liping; Chen, Zilei

    2018-03-01

    Two polar aminoglycosides, kasugamycin and validamycin-A, were determined in cereals (brown rice, wheat and corn) by high-performance liquid chromatography-tandem mass spectrometry. The analytes were extracted from samples using methanol and water (70:30, v/v) at pH 5.5, purified using both a hydrophilic-hydrophobic-balanced cartridge and a strong cation-exchange cartridge, and then analysed using multiple reaction monitoring in positive electrospray ionisation mode with a special ReproSil 100 C 18 high-performance liquid chromatography column. This newly proposed method yielded good sensitivity and excellent chromatographic performance. The limits of quantification for kasugamycin and validamycin-A were 4.1 µg/kg and 1.0 µg/kg, respectively. The recoveries for both compounds at three fortification levels (4, 100 and 500 µg/kg for kasugamycin; 1, 10 and 100 µg/kg for validamycin-A) ranged from 75% to 110%, and the relative standard deviations were below 15%.

  10. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    PubMed

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  11. Confirmation of congenital adrenal hyperplasia by adrenal steroid profiling of filter paper dried blood samples using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael

    2011-04-01

    The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.

  12. Quantitative determination of tilmicosin in canine serum by high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Herrera, Michael; Ding, Haiqing; McClanahan, Robert; Owens, Jane G; Hunter, Robert P

    2007-09-15

    A highly sensitive and quantitative LC/MS/MS assay for the determination of tilmicosin in serum has been developed and validated. For sample preparation, 0.2 mL of canine serum was extracted with 3 mL of methyl tert-butyl ether. The organic layer was transferred to a new vessel and dried under nitrogen. The sample was then reconstituted for analysis by high performance liquid chromatography-tandem mass spectrometry. A Phenomenex Luna C8(2) analytical column was used for the chromatographic separation. The eluent was subsequently introduced to the mass spectrometer by electrospray ionization. A single range was validated for 50-5000 ng/mL for support of toxicokinetic studies. The inter-day relative error (inaccuracy) for the LLOQ samples ranged from -5.5% to 0.3%. The inter-day relative standard deviations (imprecision) at the respective LLOQ levels were < or =10.1%.

  13. Evaluating the Antibacterial Properties of Polyacetylene and Glucosinolate Compounds with Further Identification of Their Presence within Various Carrot (Daucus carota) and Broccoli (Brassica oleracea) Cultivars Using High-Performance Liquid Chromatography with a Diode Array Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Analyses.

    PubMed

    Hinds, L; Kenny, O; Hossain, M B; Walsh, D; Sheehy, E; Evans, P; Gaffney, M; Rai, D K

    2017-08-23

    Ongoing consumer concerns over using synthetic additives in foods has strongly influenced efforts worldwide to source suitable natural alternatives. In this study, the antibacterial efficacy of polyacetylene and glucosinolate compounds was evaluated against both Gram positive and Gram negative bacterial strains. Falcarinol [minimum inhibitory concentration (MIC) = 18.8-37.6 μg/mL] demonstrated the best overall antibacterial activity, while sinigrin (MIC = 46.9-62.5 μg/mL) was the most active glucosinolate compound. High-performance liquid chromatography with a diode array detector analysis showed falcarinol [85.13-244.85 μg/g of dry weight (DW)] to be the most abundant polyacetylene within six of the eight carrot (Daucus carota) cultivars investigated. Meanwhile, sinigrin (100.2-244.3 μg/g of DW) was the most abundant glucosinolate present within the majority of broccoli (Brassica oleracea) cultivars investigated using ultra performance liquid chromatography-tandem mass spectrometry analysis. The high abundance of both falcarinol and sinigrin within these respective species suggests that they could serve as potential sources of natural antibacterial agents for use as such in food products.

  14. Matrix effect on the determination of synthetic corticosteroids and diuretics by liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Dikunets, M. A.; Appolonova, S. A.; Rodchenkov, G. M.

    2009-04-01

    This work presents a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) procedure for selective and reliable screening of corticosteroids and diuretics in human urine. Sample preparation included the extraction, evaporation of the organic extract under nitrogen, and solution of the dry residue. The extract was analyzed by HPLC combined with tandem mass spectrometry using electro-spraying ionization at atmospheric pressure with negative ion recording. The mass spectra of all compounds were recorded, and the characteristic ions, retention times, and detection limits were determined. The procedure was validated by evaluating the degree of the matrix suppression of ionization, extraction of analytes from human biological liquid, and the selectivity and specificity of determination.

  15. Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples

    USDA-ARS?s Scientific Manuscript database

    High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-...

  16. Simultaneous determination of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi

    2016-02-01

    A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Quantification of cefazolin in serum and adipose tissue by ultra high performance liquid chromatography-Tandem mass spectrometry (UHPLC-MS/MS): application to a pilot study of obese women undergoing cesarean delivery.

    PubMed

    Lillico, Ryan; Sayre, Casey L; Sitar, Daniel S; Davies, Neal M; Baron, Cynthia M; Lakowski, Ted M

    2016-09-15

    Higher doses of cefazolin are required in obese patients for preoperative antibiotic prophylaxis, owing to its low lipophilicity. An ultra high performance liquid chromatography-tandem mass spectrometry method was developed to quantify cefazolin in serum and adipose tissue from 6 obese patients undergoing cesarean delivery, and using stable-isotope labeled cefazolin as an internal standard. The method has a 2μg/g lower limit of quantitation. The concentration in adipose tissue was 3.4±1.6μg/mL, which is less than half of the reported minimum inhibitory concentration of 8μg/mL for cefazolin. Serum cefazolin concentrations were more than 30-fold higher than in adipose tissue. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. [Simultaneous determination of six synthetic sweeteners in food by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Liu, Xiaoxi; Ding, Li; Liu, Jinxia; Zhang, Ying; Huang, Zhiqiang; Wang, Libing; Chen, Bo

    2010-11-01

    A simple and sensitive method for the determination of six synthetic sweeteners (sodium cyclamate, saccharin sodium, acesulfame-K, aspartame, alitame and neotame) in food was developed. The synthetic sweeteners were extracted by methanol-water (1 : 1, v/v). The extract was separated on a C18 column using 0.1% (v/v) formic acid-5 mmol/L ammonium formate/acetonitrile as mobile phase, and then detected by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) using multiple reaction monitoring (MRM) mode. The good linearities (r > 0.998) were achieved for all the analytes over the range of 20-500 microg/L. The recoveries obtained ranged from 81.3% to 106.0% at three spiked concentrations, with the relative standard deviations lower than 11%. The established method has been successfully applied to the determination of synthetic sweeteners in food.

  19. High-performance Liquid Chromatographic Ultraviolet Detection of Nilotinib in Human Plasma from Patients with Chronic Myelogenous Leukemia, and Comparison with Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Nakahara, Ryosuke; Satho, Yuhki; Itoh, Hiroki

    2016-11-01

    A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na 2 PO 4 H 2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r 2 = 0.988, P < 0.01). © 2016 Wiley Periodicals, Inc.

  20. Trace determination of organophosphate esters in white wine, red wine, and beer samples using dispersive liquid-liquid microextraction combined with ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Pang, Long; Yang, Huiqiang; Yang, Peijie; Zhang, Hongzhong; Zhao, Jihong

    2017-08-15

    In this study, dispersive liquid-liquid microextraction coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry was developed for the analysis of five representative organophosphate esters (OPEs) in wine samples. Under optimized conditions, the proposed method resulted in good linearity (R 2 >0.9933) over the range of 0.1-100μgL -1 , with limits of detection (LODs, S/N =3) and quantification (LOQs, S/N =10) in the ranges of 0.48-18.8ngL -1 and 1.58-62.5ngL -1 , respectively. Inter- and intra-assay precisions of RSD% ranged from 3.21% to 6.13% and from 1.69% to 7.63%, respectively. The spiked recoveries of target OPEs from white wine, red wine, and beer samples were in the ranges of 80-122%, 76-120%, and 76-110%, respectively, at two different concentration levels. The total concentrations of five OPEs found in white wine, red wine, and beer samples were in the ranges of 0.29-0.85μgL -1 , 1.00-3.05μgL -1 , and 0.86-1.47μgL -1 , respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Measurement of serum 3-epi-25-hydroxyvitamin D3, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in infant, paediatric and adolescent populations of Korea using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Cho, Sung E; Kim, Sollip; Kim, Young D; Lee, Hyojung; Seo, Dong H; Song, Junghan; Um, Tae H; Cho, Chong R; Kim, Nam H; Hwang, Jong H

    2017-09-01

    Background We evaluated the performance of ultra-performance liquid chromatography-tandem mass spectrometry to measure serum 3-epi-25-hydroxyvitamin D 3 , 25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 2 concentrations in 519 infant, paediatric and adolescent serum samples in Korea. Methods We used a Kinetex XB-C18 column and isocratic methanol/water (77.5/22.5, v/v) with 0.025% (v/v) high-performance liquid chromatography solvent additive flowing at 0.25 mL/min, yielding an 11 min/sample run time. A TQD triple quadrupole mass spectrometer in electrospray ionization positive ion mode with multiple reaction monitoring transition via an MSMS vitamin D kit was used to evaluate precision, carryover, ion suppression and linearity. Samples were prepared using the 4-phenyl-1,2,4-triazoline-3,5-dione derivatization method. Results Intra- and inter-run precisions were 1.23-13.28% and 1.02-10.08%, respectively. Group carryovers were -0.27% and 0.10%, respectively. There was no ion suppression. The calibration curve showed good linearity from calibrator Level 1 (11.75 nmol/L) to 6 (375 nmol/L) with R 2  > 0.9999. The 3-epi-25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 3 peaks were clearly separated in the extracted ion chromatogram. Infant serum samples 3-epi-25-hydroxyvitamin D 3 concentrations were significantly higher than paediatric and adolescent concentrations. Conclusions The ultra-performance liquid chromatography-tandem mass spectrometry assay performed acceptably, clearly separating 3-epi-25-hydroxyvitamin D 3 from 25-hydroxyvitamin D 3 . High 3-epi-25-hydroxyvitamin D 3 concentrations were observed in infant but not in paediatric and adolescent serum samples.

  2. Development of a UHPLC-MS/MS method for the measurement of chlortetracycline degradation in swine manure

    USDA-ARS?s Scientific Manuscript database

    An ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed capable of simultaneously measuring chlortetracycline (CTC), epi-chlortetracycline (epi-CTC), isochlortetracycline (ICTC), oxytetracycline, and tetracycline in swine manure. A simple sample pr...

  3. Micro-solid phase extraction coupled with high-performance liquid chromatography-tandem mass spectrometry for the determination of stimulants, hallucinogens, ketamine and phencyclidine in oral fluids.

    PubMed

    Sergi, Manuel; Compagnone, Dario; Curini, Roberta; D'Ascenzo, Giuseppe; Del Carlo, Michele; Napoletano, Sabino; Risoluti, Roberta

    2010-08-24

    A confirmatory method for the determination of illicit drugs based on micro-solid phase extraction with modified tips, made of a functionalized fiberglass with apolar chains of octadecylsilane into monolithic structure, has been developed in this study. Drugs belonging to different chemical classes, such as amphetamine, methamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethylamphetamine, cocaine, benzoylecgonine, ketamine, mescaline, phencyclidine and psilocybine were analyzed. The quantitation was performed by liquid chromatography-tandem mass spectrometry and the analytes were detected in positive ionization by means of an electrospray source. The limits of quantification ranged between 0.3 ng mL(-1) for cocaine and 4.9 ng mL(-1) for psilocybine, with coefficients of determination (r(2)) >0.99 for all the analytes as recommended in the guidelines of Society of Forensic Toxicologists-American Association Forensic Sciences. 2010 Elsevier B.V. All rights reserved.

  4. Development of a UHPLC-MS/MS method for the measurement of chlortetracycline degradation in swine manure

    USDA-ARS?s Scientific Manuscript database

    An ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed capable of simultaneously measuring chlortetracycline (CTC), epi-chlortetracycline (epi-CTC) and isochlortetracycline (ICTC), as well as other structurally related tetracyclines in swine manur...

  5. Liquid chromatography-tandem mass spectrometric assay for the T790M mutant EGFR inhibitor osimertinib (AZD9291) in human plasma.

    PubMed

    Rood, Johannes J M; van Bussel, Mark T J; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W

    2016-09-15

    A method for the quantitative analysis by ultra-performance liquid chromatography-tandem mass spectrometry of the highly selective irreversible covalent inhibitor of EGFR-TK, osimertinib in human plasma was developed and validated, using pazopanib as an internal standard. The validation was performed in a range from 1 to 1000ng/ml, with the lowest level corresponding to the lower limit of quantitation. Gradient elution was performed on a 1.8μm particle trifunctional bonded C18 column by 1% (v/v) formic acid in water, and acetonitrile as mobile phase. The analyte was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer after positive ionization with the heated electrospray interface. Within-day precisions ranged from 3.4 to 10.3%, and between-day precisions from 3.8 to 10.4%, accuracies were 95.5-102.8%. Plasma (either lithium heparin or sodium EDTA) pretreatment was performed by salting-out assisted liquid-liquid extraction using acetonitrile and magnesium sulfate. This method was used to analyze the osimertinib blood plasma levels of five adult patients with metastatic T790M mutated non-small cellular lung carcinoma for therapeutic drug monitoring purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Simultaneous analysis of different classes of phytohormones in coconut (Cocos nucifera L.) water using high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry after solid-phase extraction.

    PubMed

    Ma, Zhen; Ge, Liya; Lee, Anna S Y; Yong, Jean Wan Hong; Tan, Swee Ngin; Ong, Eng Shi

    2008-03-10

    Coconut (Cocos nucifera L.) water, which contains many uncharacterized phytohormones is extensively used as a growth promoting supplement in plant tissue culture. In this paper, a high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of various classes phytohormones, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N(6)-benzyladenine (BA), alpha-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D) in young coconut water (CW). The analysis was carried out using a reverse-phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid, pH adjusted to 3.2 with triethylamine (TEA)) modified by methanol, and solute detection made at 265 nm wavelength. The method was validated for specificity, quantification, accuracy and precision. After preconcentration of putative endogenous phytohormones in CW using C(18) solid-phase extraction (SPE) cartridges, the HPLC method was able to screen for putative endogenous phytohormones present in CW. Finally, the identities of the putative phytohormones present in CW were further confirmed using independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) equipped with an electrospray ionization (ESI) interface.

  7. Determination of gymnemagenin in rat plasma using high-performance liquid chromatography-tandem mass spectrometry: application to pharmacokinetics after oral administration of Gymnema sylvestre extract.

    PubMed

    Kamble, Bhagyashree; Gupta, Ankur; Patil, Dada; Khatal, Laxman; Janrao, Shirish; Moothedath, Ismail; Duraiswamy, Basavan

    2013-05-01

    A sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the determination of gymnemagenin (GMG), a triterpene sapogenin from Gymnema sylvestre, in rat plasma using withaferin A as the internal standard (IS). Plasma samples were simply extracted using liquid-liquid extraction with tetra-butyl methyl ether. Chromatographic separation was performed on Luna C(18) column using gradient elution of water and methanol (with 0.1% formic acid and 0.3% ammonia) at a flow rate of 0.8 mL/min. GMG and IS were eluted at 4.64 and 4.36 min, ionized in negative and positive mode, respectively, and quantitatively estimated using multiple reaction monitoring (MRM) mode. Two MRM transitions were selected at m/z 505.70 → 455.5 and m/z 471.50 → 281.3 for GMG and IS, respectively. The assay was linear over the concentration range of 5.280-300.920 ng/mL. The mean plasma extraction recoveries for GMG and IS were found to be 80.92 ± 8.70 and 55.63 ± 0.76%, respectively. The method was successfully applied for the determination of pharmacokinetic parameters of GMG after oral administration of G. sylvestre extract. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Use of experimental design in the investigation of stir bar sorptive extraction followed by ultra-high-performance liquid chromatography-tandem mass spectrometry for the analysis of explosives in water samples.

    PubMed

    Schramm, Sébastien; Vailhen, Dominique; Bridoux, Maxime Cyril

    2016-02-12

    A method for the sensitive quantification of trace amounts of organic explosives in water samples was developed by using stir bar sorptive extraction (SBSE) followed by liquid desorption and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The proposed method was developed and optimized using a statistical design of experiment approach. Use of experimental designs allowed a complete study of 10 factors and 8 analytes including nitro-aromatics, amino-nitro-aromatics and nitric esters. The liquid desorption study was performed using a full factorial experimental design followed by a kinetic study. Four different variables were tested here: the liquid desorption mode (stirring or sonication), the chemical nature of the stir bar (PDMS or PDMS-PEG), the composition of the liquid desorption phase and finally, the volume of solvent used for the liquid desorption. On the other hand, the SBSE extraction study was performed using a Doehlert design. SBSE extraction conditions such as extraction time profiles, sample volume, modifier addition, and acetic acid addition were examined. After optimization of the experimental parameters, sensitivity was improved by a factor 5-30, depending on the compound studied, due to the enrichment factors reached using the SBSE method. Limits of detection were in the ng/L level for all analytes studied. Reproducibility of the extraction with different stir bars was close to the reproducibility of the analytical method (RSD between 4 and 16%). Extractions in various water sample matrices (spring, mineral and underground water) have shown similar enrichment compared to ultrapure water, revealing very low matrix effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of boldenone sulfoconjugate and related steroid sulfates in equine urine by high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Weidolf, L O; Lee, E D; Henion, J D

    1988-03-01

    Sulfoconjugated anabolic steroids were separated by micro-bore high-performance liquid chromatography. The eluent was introduced into the atmospheric pressure ion source of the triple-quadrupole mass spectrometer via an ion spray liquid chromatograph/mass spectrometer interface operated in the negative ion mode. The limit of detection was 10 pg on-column by selected ion monitoring of the molecular ion and the response increased linearly over a concentration range of 2.4 orders of magnitude. Following work-up by a liquid-solid extraction procedure of equine urine samples, full-scan daughter ion spectra of boldenone sulfate could be obtained up to 17 days after a therapeutic dose of boldenone undecylenate to a horse.

  10. Investigation of the persistence of nerve agent degradation analytes on surfaces through wipe sampling and detection with ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Willison, Stuart A

    2015-01-20

    The persistence of chemical warfare nerve agent degradation analytes on surfaces is important, from indicating the presence of nerve agent on a surface to guiding environmental restoration of a site after a release. Persistence was investigated for several chemical warfare nerve agent degradation analytes on indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces included porous/permeable (vinyl tile, painted drywall, and wood) and largely nonporous/impermeable (laminate, galvanized steel, and glass) surfaces. Wipe extracts were analyzed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). UPLC provides a separation of targeted degradation analytes in addition to being nearly four times faster than high-performance liquid chromatography, allowing for greater throughput after a large-scale contamination incident and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), GB degradate; 61-91% for ethyl methylphosphonate (EMPA), VX degradate; and 60-98% for pinacolyl methylphosphonate (PMPA), GD degradate. Recovery efficiencies for methyl phosphonate (MPA), nerve agent degradate, and ethylhydrogen dimethylphosphonate (EHDMAP), GA degradate, were lower, perhaps due to matrix effects. Diisopropyl methylphosphonate, GB impurity, was not recovered from surfaces. The resulting detection limits for wipe extracts were 0.065 ng/cm(2) for IMPA, 0.079 ng/cm(2) for MPA, 0.040 ng/cm(2) for EMPA, 0.078 ng/cm(2) for EHDMAP, and 0.013 ng/cm(2) for PMPA. The data indicate that laboratories may hold wipe samples for up to 30 days prior to analysis. Target analytes were observed to persist on surfaces for at least 6 weeks.

  11. Optimization of Sample Preparation for the Identification and Quantification of Saxitoxin in Proficiency Test Mussel Sample using Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Harju, Kirsi; Rapinoja, Marja-Leena; Avondet, Marc-André; Arnold, Werner; Schär, Martin; Burrell, Stephen; Luginbühl, Werner; Vanninen, Paula

    2015-01-01

    Saxitoxin (STX) and some selected paralytic shellfish poisoning (PSP) analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT) within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk). Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists) method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD). PMID:26610567

  12. Dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by high-performance liquid chromatography with ultraviolet detection and liquid chromatography-tandem mass spectrometry for the determination of triclosan and 2,4-dichlorophenol in water samples.

    PubMed

    Zheng, Cao; Zhao, Jing; Bao, Peng; Gao, Jin; He, Jin

    2011-06-24

    A novel, simple and efficient dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) technique coupled with high-performance liquid chromatography with ultraviolet detection (HPLC-UV) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of triclosan and its degradation product 2,4-dichlorophenol in real water samples. The extraction solvent used in this work is of low density, low volatility, low toxicity and proper melting point around room temperature. The extractant droplets can be collected easily by solidifying it at a lower temperature. Parameters that affect the extraction efficiency, including type and volume of extraction solvent and dispersive solvent, salt effect, pH and extraction time, were investigated and optimized in a 5 mL sample system by HPLC-UV. Under the optimum conditions (extraction solvent: 12 μL of 1-dodecanol; dispersive solvent: 300 of μL acetonitrile; sample pH: 6.0; extraction time: 1 min), the limits of detection (LODs) of the pretreatment method combined with LC-MS/MS were in the range of 0.002-0.02 μg L(-1) which are lower than or comparable with other reported approaches applied to the determination of the same compounds. Wide linearities, good precisions and satisfactory relative recoveries were also obtained. The proposed technique was successfully applied to determine triclosan and 2,4-dichlorophenol in real water samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Simultaneous determination of four alkaloids in Lindera aggregata by ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang

    2008-11-28

    A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.

  14. Alkaloid profiling of the traditional Chinese medicine Rhizoma corydalis using high performance liquid chromatography-tandem quadrupole time-of-flight mass spectrometry

    PubMed Central

    Sun, Mingqian; Liu, Jianxun; Lin, Chengren; Miao, Lan; Lin, Li

    2014-01-01

    Since alkaloids are the major active constituents of Rhizoma corydalis (RC), a convenient and accurate analytical method is needed for their identification and characterization. Here we report a method to profile the alkaloids in RC based on liquid chromatography-tandem quadrupole time-of-flight mass spectrometry (LC–Q-TOF-MS/MS). A total of 16 alkaloids belonging to four different classes were identified by comparison with authentic standards. The fragmentation pathway of each class of alkaloid was clarified and their differences were elucidated. Furthermore, based on an analysis of fragmentation pathways and alkaloid profiling, a rapid and accurate method for the identification of unknown alkaloids in RC is proposed. The method could also be useful for the quality control of RC. PMID:26579385

  15. Sensitive analysis of blonanserin, a novel antipsychotic agent, in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi

    2010-01-01

    A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  16. [Determination of five microcystins in drinking water by HPLC/MS/MS].

    PubMed

    Liu, Honghe; Mao, Lisha; Zhu, Zhou; Liu, Guihua; Chen, Yuhua

    2012-09-01

    A high performance liquid chromatography-tandem mass spectrometric method was established for determination of five microcystins( MC-LR,MC-LW,MC-RR, MC-LF, MC-YR)in drinking water and source water. The five microcystins in water was cleaned by 0.22 microm millipore filter, then detected by high performance liquid chromatography-tandem mass spectrometry. Identification was achieved by electrospray ionization (ESI) in positive mode using multiple reaction monitoring. The calibration curves of five microcystins showed good linearity in the range of 0.5-50 microg/L with correlation coefficient in the range of 0.9994 -1.0000. The detection limit of the method was from 0.06 microg/L to 0.08 microg/L, the recoveries of two spiking levels ranged from 91.2% to 102%, and RSDs of range from 2.11% to 3.26% were obtained. The method for determination of five microcystins in drinking water and source water by HPLC-MS/MS was of operation convenience, less interference from impurities and good accuracy, which could meet the requirements of national health standard method for the determination of microcystins in drinking water.

  17. Nonesterified fatty acid determination for functional lipidomics: comprehensive ultrahigh performance liquid chromatography-tandem mass spectrometry quantitation, qualification, and parameter prediction.

    PubMed

    Hellmuth, Christian; Weber, Martina; Koletzko, Berthold; Peissner, Wolfgang

    2012-02-07

    Despite their central importance for lipid metabolism, straightforward quantitative methods for determination of nonesterified fatty acid (NEFA) species are still missing. The protocol presented here provides unbiased quantitation of plasma NEFA species by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simple deproteination of plasma in organic solvent solution yields high accuracy, including both the unbound and initially protein-bound fractions, while avoiding interferences from hydrolysis of esterified fatty acids from other lipid classes. Sample preparation is fast and nonexpensive, hence well suited for automation and high-throughput applications. Separation of isotopologic NEFA is achieved using ultrahigh-performance liquid chromatography (UPLC) coupled to triple quadrupole LC-MS/MS detection. In combination with automated liquid handling, total assay time per sample is less than 15 min. The analytical spectrum extends beyond readily available NEFA standard compounds by a regression model predicting all the relevant analytical parameters (retention time, ion path settings, and response factor) of NEFA species based on chain length and number of double bonds. Detection of 50 NEFA species and accurate quantification of 36 NEFA species in human plasma is described, the highest numbers ever reported for a LC-MS application. Accuracy and precision are within widely accepted limits. The use of qualifier ions supports unequivocal analyte verification. © 2012 American Chemical Society

  18. Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Fosetyl-Aluminum in Airborne Particulate Matter

    PubMed Central

    Di Filippo, Patrizia; Riccardi, Carmela; Pomata, Donatella; Marsiglia, Riccardo; Console, Carla; Puri, Daniele

    2018-01-01

    Fosetyl-aluminum is a synthetic fungicide administered to plants especially to prevent diseases caused by the members of the Peronosporales and several Phytophthora species. Herein, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze residues of fosetyl-A1 in air particulate matter. This study was performed in perspective of an exposure assessment of this substance of health concern in environments where high levels of fosetly-Al, relatively to airborne particulate matter, can be found after spraying it. The cleanup procedure of the analyte, from sampled filters of atmospheric particulate matter, was optimized using a Strata X solid-phase extraction cartridge, after accelerated extraction by using water. The chromatographic separation was achieved using a polymeric column based on hydrophilic interaction in step elution with water/acetonitrile, whereas the mass spectrometric detection was performed in negative electrospray ionization. The proposed method resulted to be a simple, fast, and suitable method for confirmation purposes. PMID:29686933

  19. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    PubMed

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Determination of Grayanotoxins from Rhododendron brachycarpum in Dietary Supplements and Homemade Wine by Liquid Chromatography-Quadrupole Time-of-Flight-Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Hwang, Taeik; Noh, Eunyoung; Jeong, Ji Hye; Park, Sung-Kwan; Shin, Dongwoo; Kang, Hoil

    2018-02-28

    A sensitive and specific high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) method combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of grayanotoxins I and III in dietary supplements and homemade wine. Grayanotoxins I and III were successfully extracted using solid-phase extraction cartridges, characterized by LC-QTOF-MS, and quantitated by LC-MS/MS. The LC-MS/MS calibration curves were linear over concentrations of 10-100 ng/mL (grayanotoxin I) and 20-400 ng/mL (grayanotoxin III). Grayanotoxins I and III were found in 51 foodstuffs, with quantitative determinations revealing total toxin concentrations of 18.4-101 000 ng/mL (grayanotoxin I) and 15.3-56 000 ng/mL (grayanotoxin III). The potential of the validated method was demonstrated by successful quantitative analysis of grayanotoxins I and III in dietary supplements and homemade wine; the method appears suitable for the routine detection of grayanotoxins I and III from Rhododendron brachycarpum.

  1. Determination of molindone enantiomers in human plasma by high-performance liquid chromatography-tandem mass spectrometry using macrocyclic antibiotic chiral stationary phases.

    PubMed

    Jiang, Hongliang; Li, Yinghe; Pelzer, Mary; Cannon, Michelle J; Randlett, Christopher; Junga, Heiko; Jiang, Xiangyu; Ji, Qin C

    2008-05-30

    A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD

  2. High-throughput and simultaneous analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry in the positive and negative ionization modes.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masae; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Seno, Hiroshi

    2011-06-01

    In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C(18) column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1-2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography-tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  3. Rapid determination of yunaconitine and related alkaloids in aconites and aconite-containing drugs by ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Song, Long; Zhang, Hong; Liu, Xin; Zhao, Zhi-Li; Chen, Shi-Lin; Wang, Zheng-Tao; Xu, Hong-Xi

    2012-12-01

    Yunaconitine (YAC) is a toxic aconite alkaloid that is considered to be a hidden aconite poison since it is frequently found in body fluids from aconite poisoning patients, but has not been well studied in commonly used herbal drugs. In this paper, a rapid and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection combined with microwave-assisted extraction (MAE) was developed for high throughput simultaneous determination of YAC and six other toxic aconite alkaloids in 31 samples of crude, processed aconites and aconite-containing drugs. The optimized method showed excellent linearity, precision, accuracy and recovery for all target compounds with short run time. YAC was detected in some samples with contents from 0.015 to 10.41 mg/g. This is the first report on the determination of YAC in Radix Aconiti, Radix Aconiti Kusnezoffii and aconite-containing drugs. This newly developed method facilitates the rapid screening of YAC and related toxic aconite alkaloids and allows YAC to be used as a chemical marker for the quality control of aconites and aconite-containing drugs. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples.

    PubMed

    Liang, Ning; Huang, Peiting; Hou, Xiaohong; Li, Zhen; Tao, Lei; Zhao, Longshan

    2016-02-01

    A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min(-1), and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1-1000 ng mL(-1) (sulfamethoxazole, cefuroxime axetil), 5-1000 ng mL(-1) (tinidazole), 10-1000 ng mL(-1) (chloramphenicol), 2-1000 ng mL(-1) (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1-400 ng mL(-1) (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL(-1), respectively. The relative recoveries of the target analytes were in the range from 64.16% to 99.80% with relative standard deviations between 0.7 and 8.4%. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.

  5. Sensitive determination of D-lactic acid and L-lactic acid in urine by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Henry, H; Marmy Conus, N; Steenhout, P; Béguin, A; Boulat, O

    2012-04-01

    D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic™ R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis. Copyright © 2011 John Wiley & Sons, Ltd.

  6. A fully automated method for simultaneous determination of aflatoxins and ochratoxin A in dried fruits by pressurized liquid extraction and online solid-phase extraction cleanup coupled to ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Russo, Mariateresa; Valdés, Alberto; Ibáñez, Clara; Rastrelli, Luca

    2015-04-01

    According to current demands and future perspectives in food safety, this study reports a fast and fully automated analytical method for the simultaneous analysis of the mycotoxins with high toxicity and wide spread, aflatoxins (AFs) and ochratoxin A (OTA) in dried fruits, a high-risk foodstuff. The method is based on pressurized liquid extraction (PLE), with aqueous methanol (30%) at 110 °C, of the slurried dried fruit and online solid-phase extraction (online SPE) cleanup of the PLE extracts with a C18 cartridge. The purified sample was directly analysed by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for sensitive and selective determination of AFs and OTA. The proposed analytical procedure was validated for different dried fruits (vine fruit, fig and apricot), providing method detection and quantification limits much lower than the AFs and OTA maximum levels imposed by EU regulation in dried fruit for direct human consumption. Also, recoveries (83-103%) and repeatability (RSD < 8, n = 3) meet the performance criteria required by EU regulation for the determination of the levels of mycotoxins in foodstuffs. The main advantage of the proposed method is full automation of the whole analytical procedure that reduces the time and cost of the analysis, sample manipulation and solvent consumption, enabling high-throughput analysis and highly accurate and precise results.

  7. Quantification of isoflavones in coffee by using solid phase extraction (SPE) and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

    PubMed

    Caprioli, Giovanni; Navarini, Luciano; Cortese, Manuela; Ricciutelli, Massimo; Torregiani, Elisabetta; Vittori, Sauro; Sagratini, Gianni

    2016-09-01

    A new method for extracting isoflavones from espresso coffee (EC) was coupled with high-performance liquid chromatography-tandem mass spectrometry (MS/MS) for the first time to analyse five isoflavones, which included both a glycosilated form, genistin and the aglycons daidzein, genistein, formononetin and biochanin A. Isoflavones were extracted from coffee samples using methanol, stored in a freezer overnight to precipitate proteic or lipidic residues and purified on SPE C18 cartridges before high-performance liquid chromatography-MS/MS analysis. The recovery percentages obtained by spiking the matrix at concentrations of 10 and 100 µg l(-1) with a standard mixture of isoflavones were in the range of 70 to 104%. The limits of detection and limits of quantification were in the range of 0.015-0.3 µg l(-1) and 0.05-1 µg l(-1) , respectively. Once validated, the method was used to analyze the concentrations of isoflavones in six ECs and ten ground coffee samples. Only formononetin and biochanin A were found, and their respective concentrations ranged from 0.36 to 0.41 µg l(-1) and from 0.58 to 3.26 µg l(-1) in ECs and from 0.36 to 4.27 µg kg(-1) and from 0.71 to 3.95 µg kg(-1) in ground coffees. This method confirms the high specificity and selectivity of MS/MS systems for detecting bioactives in complex matrices such as coffee.Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Development and Validation of a Fast Procedure to Analyze Amoxicillin in River Waters by Direct-Injection LC-MS/MS

    ERIC Educational Resources Information Center

    Homem, Vera; Alves, Arminda; Santos, Lu´cia

    2014-01-01

    A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…

  9. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    ERIC Educational Resources Information Center

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  10. Simultaneous detection of six urinary pteridines and creatinine by high-performance liquid chromatography-tandem mass spectrometry for clinical breast cancer detection.

    PubMed

    Burton, Casey; Shi, Honglan; Ma, Yinfa

    2013-11-19

    Recent preliminary studies have implicated urinary pteridines as candidate biomarkers in a growing number of malignancies including breast cancer. While the developments of capillary electrophoresis-laser induced fluorescence (CE-LIF), high performance liquid chromatography (HPLC), and liquid chromatography-mass spectroscopy (LC-MS) pteridine urinalyses among others have helped to enable these findings, limitations including poor pteridine specificity, asynchronous or nonexistent renal dilution normalization, and a lack of information regarding adduct formation in mass spectrometry techniques utilizing electrospray ionization (ESI) have prevented application of these techniques to a larger clinical setting. In this study, a simple, rapid, specific, and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and optimized for simultaneous detection of six pteridines previously implicated in breast cancer and creatinine as a renal dilution factor in urine. In addition, this study reports cationic adduct formation of urinary pteridines under ESI-positive ionization for the first time. This newly developed technique separates and detects the following six urinary pteridines: 6-biopterin, 6-hydroxymethylpterin, d-neopterin, pterin, isoxanthopterin, and xanthopterin, as well as creatinine. The method detection limit for the pteridines is between 0.025 and 0.5 μg/L, and for creatinine, it is 0.15 μg/L. The method was also validated by spiked recoveries (81-105%), reproducibility (RSD: 1-6%), and application to 25 real urine samples from breast cancer positive and negative samples through a double-blind study. The proposed technique was finally compared directly with a previously reported CE-LIF technique, concluding that additional or alternative renal dilution factors are needed for proper investigation of urinary pteridines as breast cancer biomarkers.

  11. Rapid determination of tafenoquine in small volume human plasma samples by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Doyle, E; Fowles, S E; Summerfield, S; White, T J

    2002-03-25

    A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.

  12. Residue analysis and persistence evaluation of fipronil and its metabolites in cotton using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Xiaohu; Yu, Yang; Xu, Jun; Dong, Fengshou; Liu, Xingang; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan

    2017-01-01

    A simple residue analytical method based on the QuEChERS approach and high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) detection was developed for the analysis of fipronil and its three metabolites in cottonseed, cotton plant and soil. The average recoveries of four test compounds from all three matrices were 78.6-108.9% at the level of 0.005 to 0.5 mg/kg, with an RSD in the range of 0.6 to 13.7%. The limit of quantification (LOQ) of the four test compounds ranged from 0.005 to 0.01 mg/kg. The results of the residual dynamics experiments showed that fipronil dissipated rapidly in cotton plants and soil and that oxidation and photolysis were the main degradation pathways. Moreover, the bi-exponential models demonstrated a good fit of the measured data for fipronil in cotton plants and soil, with R2 in the range of 0.8989 to 0.9989. Furthermore, a total of 40 samples of cottonseed from Shandong Province were analyzed, and all of the samples were free from the four test compound residues.

  13. Residue analysis and persistence evaluation of fipronil and its metabolites in cotton using high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Wu, Xiaohu; Yu, Yang; Xu, Jun; Dong, Fengshou; Liu, Xingang; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan

    2017-01-01

    A simple residue analytical method based on the QuEChERS approach and high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) detection was developed for the analysis of fipronil and its three metabolites in cottonseed, cotton plant and soil. The average recoveries of four test compounds from all three matrices were 78.6–108.9% at the level of 0.005 to 0.5 mg/kg, with an RSD in the range of 0.6 to 13.7%. The limit of quantification (LOQ) of the four test compounds ranged from 0.005 to 0.01 mg/kg. The results of the residual dynamics experiments showed that fipronil dissipated rapidly in cotton plants and soil and that oxidation and photolysis were the main degradation pathways. Moreover, the bi-exponential models demonstrated a good fit of the measured data for fipronil in cotton plants and soil, with R2 in the range of 0.8989 to 0.9989. Furthermore, a total of 40 samples of cottonseed from Shandong Province were analyzed, and all of the samples were free from the four test compound residues. PMID:28291815

  14. Simultaneous quantification of preactivated ifosfamide derivatives and of 4-hydroxyifosfamide by high performance liquid chromatography-tandem mass spectrometry in mouse plasma and its application to a pharmacokinetic study.

    PubMed

    Deroussent, Alain; Skarbek, Charles; Maury, Adeline; Chapuis, Hubert; Daudigeos-Dubus, Estelle; Le Dret, Ludivine; Durand, Sylvère; Couvreur, Patrick; Desmaële, Didier; Paci, Angelo

    2015-06-15

    The antitumor drug, ifosfamide (IFO), requires activation by cytochrome P450 (CYP) to form the active metabolite, 4-hydroxyisfosfamide (4-OHIFO), leading to toxic by-products at high dose. In order to overcome these drawbacks, preactivated ifosfamide derivatives (RXIFO) were designed to release 4-OHIFO without CYP involvement. A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the simultaneous quantification of 4-OHIFO, IFO and four derivatives RXIFO in mouse plasma using multiple reaction monitoring. Because of its instability in plasma, 4-OHIFO was immediately converted to the semi-carbazone derivative, 4-OHIFO-SCZ. For the six analytes, the calibration curves were linear from 20 to 5000ng/mL in 50μL plasma and the lower limit of quantitation was determined at 20ng/mL with accuracies within ±10% of nominal and precisions less than 12%. Their recoveries ranged from 62 to 96% by using liquid-liquid extraction. With an improved assay sensitivity compared to analogues, the derivative 4-OHIFO-SCZ was stable in plasma at 4°C for 24h and at -20°C for three months. For all compounds, the assay was validated with accuracies within ±13% and precisions less than 15%. This method was applied to a comparative pharmacokinetic study of 4-OHIFO from IFO and three derivatives RXIFO in mice. This active metabolite was produced by some of the novel conjugates with good pharmacokinetic properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients.

    PubMed

    Yagi, Shigeaki; Nishizawa, Manabu; Ando, Itiro; Oguma, Shiro; Sato, Emiko; Imai, Yutaka; Fujiwara, Masako

    2016-08-01

    A simple, rapid, and selective method for determination of plasma biotin was developed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After single-step protein precipitation with methanol, biotin and stable isotope-labeled biotin as an internal standard (IS) were chromatographed on a pentafluorophenyl stationary-phase column (2.1 × 100 mm, 2.7 μm) under isocratic conditions using 10 mm ammonium formate-acetonitrile (93:7, v/v) at a flow rate of 0.6 mL/min. The total chromatographic runtime was 5 min for each injection. Detection was performed in a positive electrospray ionization mode by monitoring selected ion transitions at m/z 245.1/227.0 and 249.1/231.0 for biotin and the IS, respectively. The calibration curve was linear in the range of 0.05-2 ng/mL using 300 μL of plasma. The intra- and inter-day precisions were all <7.1%. The accuracy varied from -0.7 to 8.2%. The developed UHPLC-MS/MS method was successfully applied to determine plasma biotin concentrations in hemodialysis patients. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Determination of 82 veterinary drugs in swine waste lagoon sludge by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Xiaowei; Guo, Ping; Shan, Yawen; Ke, Yuebin; Li, Hui; Fu, Qin; Wang, Yingyu; Liu, Tianhe; Xia, Xi

    2017-05-26

    This work reports the development of a multi-residue method for the identification and quantification of 82 veterinary drugs belonging to different chemical classes in swine waste lagoon. The proposed method applies a solid-phase extraction procedure with Oasis PRiME HLB cartridges that combines isolation of the compounds and sample clean-up in a single step. Analysis is performed by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9.5min. Linearity was studied in the range between 1 and 500μgkg -1 using standards prepared both in pure solvent and in the presence of matrix, showing coefficients of determination higher than 0.99 for all the analytes except for cefapirin in matrix. The average recoveries were in the range of 60-110% for most of the compounds tested with inter-day relative standard deviations below 17%. More than 97% of the investigated compounds had less or equal to a 5μgkg -1 quantitation limit in the studied matrix. Finally, the method was used with success to detect and quantify veterinary drugs residues in real samples with sulfonamides, quinolones, and tetracyclines being the most frequently determined compound groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [Determination of antibiotics in oral hygiene products by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhou, Weijun; Xie, Zhengfu; Shao, Linzhi

    2012-07-01

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/ MS) method was developed for simultaneous determination of 13 antibiotics in oral hygiene products, including five tetracyclines, three macrolides, two quinolones, one beta-lactam and two lincosamides. The sample was extracted with 0.1% (volume percentage, same hereinafter) formic acid-acetonitrile (95:5, v/v), then centrifuged, filtered and diluted. The target compounds were separated on a C18 column (150 mm x 2.1 mm, 5 microm) with a gradient elution of 0. 1% formic acid and acetonitrile as the mobile phases, and detected by tandem mass spectrometry in positive electrospray ionization and multiple reaction monitoring (MRM) mode. The quantification of 13 antibiotics was performed by the external standard method. The calibration curves showed good linearity in the range of 5.0-50.0 microg/L with detection limits of 10.0 mg/kg. The recoveries of antibiotics in mouthwash and toothpaste samples at the three spiked levels of 10, 20 and 100 mg/kg were in the range of 80.1%-115% with the relative standard deviations in the range of 0.94%-8.69%. This method is accurate, reliable, simple, and suitable for the analysis of antibiotics in oral hygiene products.

  18. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp.

    PubMed

    Chen, Guoqiang; Hoptroff, Michael; Fei, Xiaoqing; Su, Ya; Janssen, Hans-Gerd

    2013-11-22

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal standard. Atmospheric pressure chemical ionization (APCI) in positive mode was applied for the detection of climbazole. For quantification, multiple reaction monitoring (MRM) transition 293.0>69.0 was monitored for climbazole, and MRM transition 296.0>225.1 for the deuterated climbazole. The linear range ran from 4 to 2000 ng mL(-1). The limit of detection (LOD) and the limit of quantification (LOQ) were 1 ng mL(-1) and 4 ng mL(-1), respectively, which enabled quantification of climbazole on artificial skin and human scalp at ppb level (corresponding to 16 ng cm(-2)). For the sampling of climbazole from human scalp the buffer scrub method using a surfactant-modified phosphate buffered saline (PBS) solution was selected based on a performance comparison of tape stripping, the buffer scrub method and solvent extraction in in vitro studies. Using this method, climbazole deposition in in vitro and in vivo studies was successfully quantified. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Simultaneous determination of sulfonamides, penicillins and coccidiostats in pork by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nebot, C; Regal, P; Miranda, J; Cepeda, A; Fente, C

    2012-05-01

    Veterinary drugs are widely and legally used to treat and prevent disease in livestock. However, drugs are also used illegally as growth-promoting agents. To protect the health of consumers, maximum residue limits (MRL) in food of animal origin have been established and are listed in Regulation 37/2010. According to this regulation, more than 300 drugs need to be controlled regularly in laboratories for residues of veterinary drugs. A cost-effective analytical method is very important and explains why the development of multi-residual methods is becoming popular in laboratories. The aim of this work is to describe a simple, rapid and economical high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous identification and quantification of 21 veterinary drugs in pork muscle samples. The sample clean-up procedure is performed with acidified dichloromethane and does not require solid phase extraction. The method is applicable to nine sulfonamides and seven coccidiostats identified within 36 min. Calculated relevant validation parameters such as recoveries (from 72.to 126 %), intra-precision and intermediate precision (relative standard deviation below 40 %) and decision limits (below 7 µg Kg(-1)) were within acceptable range and in compliance with the requirements of Commission Decision 2002/657/EC. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  20. A comparative pharmacokinetic study of three flavonoids and three anthraquinones in normal and gastrointestinal motility disorders rat plasma after the oral administration of Wei-Chang-Shu tablet using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ren, Yan; Zhao, Weiwei; Zhao, Juanjuan; Chen, Xiangming; Yu, Chen; Liu, Mengan

    2017-11-01

    A simple, fast and reliable high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification and pharmacokinetic study of three flavonoids (liquiritigenin, isoliquiritigenin and formononetin) and three anthraquinones (emodin, rhein and aloe-emodin), which are the bioactive ingredients of Wei-Chang-Shu tablet found in rat plasma. After extraction by liquid-liquid extraction with ethyl acetate, chromatographic separation was achieved on an Agilent Zorbax SB-C 18 column (4.6 × 150 mm, 5 μm) at a flow rate of 1 mL/min by gradient elution using 0.1% aqueous acetic acid and acetonitrile. The detection was performed using a triple quadrupole mass spectrometer equipped with electrospray ionization source in the negative ionization and selected reaction monitoring mode. Method validation was performed in terms of specificity, carryover, linearity (r > 0.99), intra-/inter-day precision (1.0-10.1%), accuracy (relative error, <7.6%), stability (0.6-13.2%), extract recovery (74.9-91.9%) and matrix effect (89.1-109%). The lower limits of quantification of the six analytes varied from 0.92 to 10.4 ng/mL. The validated method was successfully applied to compare the pharmacokinetic properties of Wei-Chang-Shu tablet in normal rats and in rats with gastrointestinal motility disorders. The results indicated that there were obvious differences in the pharmacokinetic behavior between normal and model rats. This study will be helpful in the clinical application of Wei-Chang-Shu tablet. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Salting-out assisted liquid-liquid extraction coupled to ultra-high performance liquid chromatography-tandem mass spectrometry for the determination of tetracycline residues in infant foods.

    PubMed

    Moreno-González, David; García-Campaña, Ana M

    2017-04-15

    The use of salting-out assisted liquid-liquid extraction (SALLE) combined with ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) has been evaluated for the determination of tetracyclines in infant foods based on meat and vegetables or in milk. To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized. Analytical performances of the method were satisfactory, obtaining limits of quantification lower than 0.48μgkg -1 in all cases. The precision, expressed as relative standard deviation (%, RSD) was below 11.3%. The extraction efficiency for fortified samples ranged from 89.2 to 96.8%, with RSDs lower than 7.3%. Matrix effect was evaluated for all samples studied, being lower than |21|% in all cases. In relation to the low solvent consumption, the proposed methodology could be considered rapid, cheap and environmentally friendly. Its applicability has been successfully tested in a wide range of infant foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Ultra-high-pressure liquid chromatography-tandem mass spectrometry for the analysis of six resorcylic acid lactones in bovine milk.

    PubMed

    Xia, Xi; Li, Xiaowei; Ding, Shuangyang; Zhang, Suxia; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong

    2009-03-20

    This work reports a rapid, reliable and sensitive multi-residue method for the simultaneous determination of six resorcylic acid lactones in bovine milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The resorcylic acid lactones were extracted, purified, and concentrated from milk samples in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric mixed-mode anion-exchange sorbent. The analysis was performed on a Waters Acquity BEH C(18) column utilizing a gradient elution profile. Each LC run was completed in 3.5 min. The analytes were detected by multiple reaction monitoring (MRM) using electrospray ionization (ESI) negative mode. Mean recoveries from fortified samples ranged from 92.6% to 112.5%, with relative standard deviations lower than 11.4%. Using 5 mL bovine milk, the limits of detection and quantification for resorcylic acid lactones were in the ranges of 0.01-0.05 and 0.05-0.2 microg/L, respectively. The application of this newly developed method was demonstrated by analyzing bovine milk samples from markets.

  3. Determination of perfluorinated chemicals in food and drinking water using high-flow solid-phase extraction and ultra-high performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Chang, Ying-Chia; Chen, Wen-Ling; Bai, Fang-Yu; Chen, Pau-Chung; Wang, Gen-Shuh; Chen, Chia-Yang

    2012-01-01

    For this study, we developed methods of determining ten perfluorinated chemicals in drinking water, milk, fish, beef, and pig liver using high-flow automated solid-phase extraction (SPE) and ultra-high performance liquid chromatography/tandem mass spectrometry. The analytes were separated on a core-shell Kinetex C18 column. The mobile phase was composed of methanol and 10-mM N-methylmorpholine. Milk was digested with 0.5 N potassium hydroxide in Milli-Q water, and was extracted with an Atlantic HLB disk to perform automated SPE at a flow rate ranged from 70 to 86 mL/min. Drinking water was directly extracted by the SPE. Solid food samples were digested in alkaline methanol and their supernatants were diluted and also processed by SPE. The disks were washed with 40% methanol/60% water and then eluted with 0.1% ammonium hydroxide in methanol. Suppression of signal intensity of most analytes by matrixes was lower than 50%; it was generally lower in fish and drinking water but higher in liver. Most quantitative biases and relative standard deviations were lower than 15%. The limits of detection for most analytes were sub-nanograms per liter for drinking water and sub-nanograms per gram for solid food samples. This method greatly shortened the time and labor needed for digestion, SPE, and liquid chromatography. This method has been applied to analyze 14 types of food samples. Perfluorooctanoic acid was found to be the highest among the analytes (median at 3.2-64 ng/g wet weight), followed by perfluorodecanoic acid (0.7-25 ng/g) and perfluorododecanoic acid (0.6-15 ng/g).

  4. [Determination of capsaicinoids and eugenol in waste-edible-oil by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Zhong; Ren, Fei; Zhang, Pan

    2012-11-01

    A method was developed for the determination of capsaicinoids (capsaicin, dihydrocapsaicin and synthetic capsaicin) and eugenol in waste-edible-oil extracted by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The capsaicinoids and eugenol in waste-edible-oil were extracted by methanol, and then separated by a SUPEL COSIL ABZ + Plus dC18 column (150 mm x4.6 mm, 5 microm). The analysis was performed by MS/MS with electrospray ionization in positive and negative ion modes with multiple reaction monitoring (MRM). The limits of detection for capsaicin, dihydrocapsaicin, synthetic capsaicin and eugenol were 0.02, 0.03, 0.03 and 0.6 microg/L, respectively. The good linear relationships were obtained in certain concentration ranges of capsaicinoids and eugenol. The relative standard deviations (RSDs, n=5) of same-worker and different-worker were less than 5%. The method is exclusive, sensitive and accurate, and can be used in waste-edible-oil determination.

  5. Simultaneous Determination of Isopyrazam and Azoxystrobin in Cucumbers by Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Hu, Dan; Xu, Xu; Cai, Tian; Wang, Wei-Ying; Wu, Chun-Jie; Ye, Li-Ming

    2017-12-01

    A rapid and sensitive analytical method based on high-performance liquid chromatography-tandem mass spectrometry was developed and validated for the determination of isopyrazam (IZM) and azoxystrobin (AZT) in cucumbers. A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used as the pretreatment procedure. The samples were extracted with acetonitrile and cleaned up with octadecylsilyl silica (C18) and graphite carbon black. The proposed method resulted in satisfactory recovery of IZM and AZT (91.48 to 114.62%), and relative standard deviations were less than 13.1% at fortification concentrations of 1, 20, and 500 μg kg -1 (n = 3). The limits of quantification for IZM and AZT were 0.498 and 0.499 μg kg -1 , respectively, which are far below the maximum residue level (0.5 mg kg -1 ) established for this type of sample. Matrix effects were also evaluated. This study established a sensitive and fast method for the detection of IZM and AZT in cucumber samples.

  6. Determination of chokeberry (Aronia melanocarpa) polyphenol components using liquid chromatography-tandem mass spectrometry: Overall contribution to antioxidant activity.

    PubMed

    Lee, Ji Eun; Kim, Gon-Sup; Park, Semin; Kim, Yun-Hi; Kim, Man-Bae; Lee, Won Sup; Jeong, Sung Woo; Lee, Soo Jung; Jin, Jong Sung; Shin, Sung Chul

    2014-03-01

    The type and content of plant polyphenols can be influenced by maturity. Korean chokeberry (Aronia melanocarpa) leaves of three different maturities (young, mature, and aged) were extracted with 70% aqueous methanol. The polyphenols in the leaves were analysed for the first time using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and comparison with reported data. Among the 12 characterised components, five flavonoids, 3, 4, and 10-12, and a dicaffeoylquinic acid derivative, 6, were characterised for the first time in chokeberry leaves. Each polyphenol component was validated and quantified using a representative polyphenol standard of the same group. The antioxidant activity of the three different mature leaf extracts was determined. The antioxidant activity was highest for young leaves, followed by mature and aged leaves. The results suggest that younger chokeberry leaves may be more favourable for processing a higher quality functional tea due to their higher polyphenol content. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Ultra-high-pressure liquid chromatography-tandem mass spectrometry method for the determination of alkylphenols in soil.

    PubMed

    Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei

    2009-03-20

    A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.

  8. Identification of kinetin and kinetin riboside in coconut (Cocos nucifera L.) water using a combined approach of liquid chromatography-tandem mass spectrometry, high performance liquid chromatography and capillary electrophoresis.

    PubMed

    Ge, Liya; Yong, Jean Wan Hong; Goh, Ngoh Khang; Chia, Lian Sai; Tan, Swee Ngin; Ong, Eng Shi

    2005-12-27

    Kinetin (free base and riboside), which was assumed by many scientists to be a synthetic cytokinin plant growth hormone, has been detected for the first time in the endosperm liquid of fresh young coconut fruits ("coconut water"). To facilitate the study, we developed a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the identification and quantification of kinetin and kinetin riboside in purified coconut water extract sample. Following a solid-phase extraction of cytokinins in coconut water using C18 columns, the samples were further purified by Oasis MCX columns and analyzed by LC-MS/MS for kinetin and kinetin riboside. Detection by mass spectrometry was carried out using selected reaction monitoring (SRM) mode, by identifying the putative kinetin and kinetin riboside based on their characteristic fragments. Based on a signal-to-noise ratio of 3, the limits of detection in SRM mode were 0.02 microM and 0.005 microM for kinetin and kinetin riboside, respectively. Furthermore, optimal conditions for a baseline chromatographic separation of 18 cytokinin standards by high performance liquid chromatography (HPLC) were developed. The HPLC method had been employed for the confirmation and further fractionation of kinetin in coconut water extracts. The confirmation and fractionation of kinetin riboside was carried out using a further modified HPLC program due to the presence of other interfering material(s) in the sample matrix. Finally, fractions of putative kinetin and kinetin riboside collected from HPLC eluate of coconut water sample were further authenticated by independent capillary zone electrophoresis (CZE) experiment.

  9. Quantification of 31 illicit and medicinal drugs and metabolites in whole blood by fully automated solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Bjørk, Marie Kjærgaard; Simonsen, Kirsten Wiese; Andersen, David Wederkinck; Dalsgaard, Petur Weihe; Sigurðardóttir, Stella Rögn; Linnet, Kristian; Rasmussen, Brian Schou

    2013-03-01

    An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography-tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm × 2.1 mm, 1.7 μm Acquity UPLC CSH C(18) column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.

  10. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  11. Simultaneous determination of naringenin and hesperetin in rats after oral administration of Da-Cheng-Qi decoction by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Ying; Xu, Fengguo; Zhang, Zunjian; Song, Rui; Tian, Yuan

    2008-07-01

    To quantify naringenin and hesperetin in rat plasma after oral administration of Da-Cheng-Qi decoction, a famous purgative traditional Chinese medicine, a high-performance liquid chromatography-tandem mass spectrometry method was developed and validated. The HPLC separation was carried out on a Zorbax SB-C(18) column using 0.1% formic acid-methanol as mobile phase and estazolam as internal standard after the sample of rat plasma had been cleaned up with one-step protein precipitation using methanol. Atmospheric pressure chemical ionization in the positive ion mode and selected reaction monitoring method was developed to determine the active components. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-batch variation). The recoveries of naringenin and hesperetin were 72.8-76.6 and 75.7-77.2%, respectively. Linearity in rat plasma was observed over the range of 0.5-250 ng/mL (r2 > 0.99) for both naringenin and hesperetin. The accuracy and precision were well within the acceptable range and the relative standard deviation of the measured rat plasma samples was less than 15% (n = 5). The validated method was successfully applied for the evaluation of the pharmacokinetics of naringenin and hesperetin administered to six rats.

  12. Multiresidue analysis of sulfonamides, quinolones, and tetracyclines in animal tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Zhiwen; Li, Xiaowei; Ding, Shuangyang; Jiang, Haiyang; Shen, Jianzhong; Xia, Xi

    2016-08-01

    A multiresidue method for the efficient identification and quantification of 38 compounds from 3 different classes of antibiotics (tetracyclines, sulfonamides, and quinolones) in animal tissues has been developed. The method optimization involved the selection of extraction solutions, comparison of different solid-phase extraction cartridges and different mobile phases. As a result, the samples were extracted with Mcllvaine and phosphate buffers, followed by clean-up step based on solid-phase extraction with Oasis HLB cartridge. All compounds were determined by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9min. The method efficiency was evaluated in 5 tissues including muscle, liver, and kidney, and the mean recoveries ranged from 54% to 102%, with inter-day relative standard deviation lower than 14%. The limits of quantification were between 0.5 and 10μg/kg, which were satisfactory to support future surveillance monitoring. The developed method was applied to the analysis of swine liver and chicken samples from local markets, and sulfamethazine was the most commonly detected compound in the animal samples, with the highest residue level of 998μg/kg. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Multi-target determination of organic ultraviolet absorbents in organism tissues by ultrasonic assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Peng, Xianzhi; Jin, Jiabin; Wang, Chunwei; Ou, Weihui; Tang, Caiming

    2015-03-06

    A sensitive and reliable method was developed for multi-target determination of 13 most widely used organic ultraviolet (UV) absorbents (including UV filters and UV stabilizers) in aquatic organism tissues. The organic UV absorbents were extracted using ultrasonic-assisted extraction, purified via gel permeation chromatography coupled with silica gel column chromatography, and determined by ultra-high performance liquid chromatography-tandem mass spectrometry. Recoveries of the UV absorbents from organism tissues mostly ranged from 70% to 120% from fish filet with satisfactory reproducibility. Method quantification limits were 0.003-1.0ngg(-1) dry weight (dw) except for 2-ethylhexyl 4-methoxycinnamate. This method has been applied to analysis of the UV absorbents in wild and farmed aquatic organisms collected from the Pearl River Estuary, South China. 2-Hydroxy-4-methoxybenzophenone and UV-P were frequently detected in both wild and farmed marine organisms at low ngg(-1)dw. 3-(4-Methylbenzylidene)camphor and most of the benzotriazole UV stabilizers were also frequently detected in maricultured fish. Octocrylene and 2-ethylhexyl 4-methoxycinnamate were not detected in any sample. This work lays basis for in-depth study about bioaccumulation and biomagnification of the UV absorbents in marine environment. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of chlorantraniliprole and cyantraniliprole in fruits, vegetables and cereals using ultra-high-performance liquid chromatography-tandem mass spectrometry with the isotope-labelled internal standard method.

    PubMed

    Pan, Xinglu; Dong, Fengshou; Xu, Jun; Liu, Xingang; Chen, Zenglong; Liu, Na; Chen, Xixi; Tao, Yan; Zhang, Hongjun; Zheng, Yongquan

    2015-05-01

    A reliable and sensitive isotope-labelled internal standard method for simultaneous determination of chlorantraniliprole and cyantraniliprole in fruits (apple and grape), vegetables (cucumber and tomato) and cereals (rice and wheat) using ultra-high-performance liquid chromatography-tandem mass spectrometry was developed. Isotope-labelled internal standards were effective in compensating for the loss in the pretreatment and overcoming the matrix effect. The analytes were extracted with acetonitrile and cleaned up with different kinds of sorbents. The determination of the target compounds was achieved in less than 4 min using a T3 column combined with an electrospray ionization source in positive mode. The overall average relative recoveries in all matrices at three spiking levels (10, 20 and 50 μg kg(-1)) ranged from 95.5 to 106.2 %, with all relative standard deviations being less than 14.4 % for all analytes. The limits of detection did not exceed 0.085 μg kg(-1) and the limits of quantification were below 0.28 μg kg(-1) in all matrices. The method was demonstrated to be convenient and accurate for the routine monitoring of chlorantraniliprole and cyantraniliprole in fruits, vegetables and cereals.

  15. Residue analysis and degradation studies of fenbuconazole and myclobutanil in strawberry by chiral high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Hu; Wang, Xinquan; Qian, Mingrong; Wang, Xiangyun; Xu, Hao; Xu, Mingfei; Wang, Qiang

    2011-11-23

    A simple and sensitive enantioselective method for the determination of fenbuconazole and myclobutanil in strawberry was developed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Fenbuconazole and myclobutanil residues in strawberry were extracted with acetonitrile containing 1% acetic acid, and an aliquot was cleaned up with PSA (primary and secondary amine) and C(18) sorbent. The direct resolution of fenbuconazole and myclobutanil enantiomers was performed on a cellulose tris (3,5-dimethylphenylcarbamate) column using acetonitrile-0.1% formic acid solution (60:40, v/v) as the mobile phase. Quantification was achieved using matrix-matched standard calibration curves, and the limits of quantification for fenbuconazole and myclobutanil enantiomers in strawberry were both 2 μg/kg. The method was successfully utilized to investigate the probable enantioselective degradation of fenbuconazole and myclobutanil in strawberry. The results showed that the degradation of the fenbuconazole and myclobutanil enantiomers in strawberry followed pseudofirst-order kinetics (R(2) > 0.97). The results from this study revealed that the degradation of fenbuconazole in strawberry was not enantioselective, while the degradation of myclobutanil was enantioselective, and the (+)-myclobutanil showed a faster degradation than (-)-myclobutanil in strawberry, resulting in the relative enrichment of (-)-myclobutanil in residue. The results could provide a reference to fully evaluate the risks of these two fungicides.

  16. [Determination of deoxynivalenol in grain and its products by solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Huang, Juan; Chen, Guosong; Zhang, Xiaoyan; Shen, Chongyu; Lü, Chen; Wu, Bin; Liu, Yan; Chen, Huilan; Ding, Tao

    2012-11-01

    A method was established for the determination of deoxynivalenol (vomitoxin) in grain and its products based on solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was firstly extracted by acetonitrile-water (84:16, v/v). The extract was then cleaned-up by an HLB solid phase extraction cartridge. The separation was carried out on a Phenomenex Kinetex C18 column (100 mm x4. 6 mm, 2.6 microm) with a gradient elution using 0.3% per hundred ammonia solution-acetonitrile as mobile phases. The analysis of deoxynivalenol was performed under electrospray negative ionization mode. The limit of detection (LOD, S/N= 3) and the limit of quantification (LOQ, S/N = 10) were 20 microg/kg and 50 microg/kg, respectively. A good linearity (r > 0.99) was achieved for the target compound over the range of 20-1000 pg/L. The recoveries at the three spiked levels (50, 100, 500 microg/kg) in the blank matrices such as flour, barley, soybean, rice, cornmeal, cassava and wheat, were varied from 75.6% to 111.0% with the relative standard deviations no more than 13. 0%. The method is accurate, efficient, sensitive and practical. The cost of pretreatment is obviously reduced by replacing immunoaffinity columns and Mycosep columns with HLB columns which have the same purification effect.

  17. Biomonitoring of 21 endocrine disrupting chemicals in human hair samples using ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rodríguez-Gómez, R; Martín, J; Zafra-Gómez, A; Alonso, E; Vílchez, J L; Navalón, A

    2017-02-01

    Rapid industrial growth has increased human exposure to a large variety of chemicals with adverse health effects. These industrial chemicals are usually present in the environment, foods, beverages, clothes and personal care products. Among these compounds, endocrine disrupting chemicals (EDCs) have raised concern over the last years. In the present work, the determination of 21 EDCs in human hair samples is proposed. An analytical method based on the digestion of the samples with a mixture of acetic acid/methanol (20:80, v/v) followed by a solid-liquid microextraction and analysis by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed and validated. The most influential parameters affecting the extraction method were optimized. The method was validated using matrix-matched calibration and recovery assays. Limits of detection ranged from 0.2 to 4 ng g -1 , limits of quantification from 0.5 to 12 ng g -1 , and inter- and intra-day variability was under 15% in all cases. Recovery rates for spiked samples ranged from 92.1 to 113.8%. The method was applied for the determination of the selected compounds in human hair. Samples were collected weekly from six randomly selected volunteers (three men and three women) over a three-month period. All the analyzed samples tested positive for at least one of the analyzed compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Accurate Quantitation and Analysis of Nitrofuran Metabolites, Chloramphenicol, and Florfenicol in Seafood by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry: Method Validation and Regulatory Samples.

    PubMed

    Aldeek, Fadi; Hsieh, Kevin C; Ugochukwu, Obiadada N; Gerard, Ghislain; Hammack, Walter

    2018-05-23

    We developed and validated a method for the extraction, identification, and quantitation of four nitrofuran metabolites, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ), semicarbazide (SC), and 1-aminohydantoin (AHD), as well as chloramphenicol and florfenicol in a variety of seafood commodities. Samples were extracted by liquid-liquid extraction techniques, analyzed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), and quantitated using commercially sourced, derivatized nitrofuran metabolites, with their isotopically labeled internal standards in-solvent. We obtained recoveries of 90-100% at various fortification levels. The limit of detection (LOD) was set at 0.25 ng/g for AMOZ and AOZ, 1 ng/g for AHD and SC, and 0.1 ng/g for the phenicols. Various extraction methods, standard stability, derivatization efficiency, and improvements to conventional quantitation techniques were also investigated. We successfully applied this method to the identification and quantitation of nitrofuran metabolites and phenicols in 102 imported seafood products. Our results revealed that four of the samples contained residues from banned veterinary drugs.

  19. Quantification of the antiplasmodial alkaloid carpaine in papaya (Carica papaya) leaves.

    PubMed

    Julianti, Tasqiah; Oufir, Mouhssin; Hamburger, Matthias

    2014-08-01

    Daily consumption of papaya (Carica papaya) leaves as greens and an herbal infusion is common in some parts of Indonesia as a means for preventing malaria. Antiplasmodial activity of the leaf extracts and of the main alkaloid carpaine were recently confirmed. A quantitative assay for determination of carpaine in papaya leaves was developed and validated. The assay involved pressurized liquid extraction and quantification with the aid of ultrahigh-performance liquid chromatography-tandem mass spectroscopy. Extraction conditions were optimized with respect to solvent, temperature, and number of extraction cycles. The ultrahigh-performance liquid chromatography-tandem mass spectroscopy assay was validated over a range of 20-5000 ng/mL (R(2) of 0.9908). A total of 29 papaya leaf samples were analyzed, and carpaine concentration in dry leaves was found to range from 0.02 to 0.31%. No obvious dependence on geographic origin and leaf maturity was observed. Georg Thieme Verlag KG Stuttgart · New York.

  20. [Determination of 6 kinds of plant growth regulator in bean sprout by ultra high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Liu, Ping; Fan, Sai; Wu, Guohua; Zhao, Rong; Liu, Wei; Zhao, Xudong

    2016-05-01

    A method for the simultaneous determination of 6 plant growth regulator (PGR) residues in bean sprout was developed by ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). 6-Benzylaminopurine, isopentennyladenine, 4-chlorophenoxyacetic acid, 4-fluorophenoxyacetic acid, indole-3- acetic acid and indole-3-butyric acid were concerned. Bean sprout samples were extracted by acetonitrile and QuEChERS extraction kit, purified by C18 powers. After centrifugation, the sample liquids was diluted 10 times by ultrapure water. The chromatographic analysis was carried out on an waters acquity UPLC BEH C18 column( 100 mm x 2.1 mm, 1.7 microm). The analyzer confirmed and quantified by mass spectrum of triple quadrupole in the multiple reaction monitoring (MRM) mode and quantified by matrix-matched external standard method. The calibration curves showed good linearity in each range with correlation coefficients greater than 0.998. 3 levels spiked recoveries were carried out using blank bean sprout extraction as substrate, the recoveries ranged from 84.2% to 107.5%, the relative standard deviations (RSDs) ranged from 3.08% to 12.71%. The qualitative limits of detections (S/N = 3) were 0.03-3.0 microg/kg and the quantitative limits(S/N = 10) were 0.1-10.0 microg/kg for the 6 PGRs. The method is simple and easy to operate, with less organic reagent, high sensitivity and good stability. It is suitable for the detection of 6 kinds of plant growth regulators in bean sprouts.

  1. [Simultaneous determination of 6 forbidden colorants in cosmetics by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Lin, Weixuan; Sun, Xingquan; Zhao, Xuerong; Xu, Wei; Guo, Guiyuan

    2012-05-01

    A method of high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been established for the simultaneous determination of six forbidden colorants including Sudan IV, Acid Violet 49, Sudan Blue 2, Solvent Red 49, Basic Violet 1 and Pigment Orange 5 in cream and powdery matrix cosmetics. The samples were extracted with ethanol-acetonitrile (3:2, v/v) solution by ultrasonic technique for 20 min, then centrifuged for purification and enriched by nitrogen blowing sequentially. The analytes were isolated on a Luna C18 column (150 mm x 2.1 mm, 5 microm) by gradient elution with methanol and 10 mmol/L ammonium acetate as the mobile phases, and detected by MS/MS in the multiple reaction monitoring (MRM) mode. The qualitative analysis was based on the retention time and the relative abundance ratio of the characteristic ions, and the quantitative analysis on calibration curve method. The results showed that the limits of quantification (LOQ, S/N= 10) of the six colorants ranged from 0.1 to 10 microg/kg and the average recoveries were from 86.67% to 98.22% with the relative standard deviations (RSDs) from 4.01% to 7.01%. The method is simple and rapid with high sensitivity and good reproducibility, and suitable for the determination of the six forbidden colorants in cosmetics.

  2. A simple, rapid and novel method based on salting-out assisted liquid-liquid extraction for ochratoxin A determination in beer samples prior to ultra-high performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Mariño-Repizo, Leonardo; Goicoechea, Hector; Raba, Julio; Cerutti, Soledad

    2018-06-07

    A novel, simple, easy and cheap sample treatment strategy based on salting-out assisted liquid-liquid extraction (SALLE) for ochratoxin A (OTA) ultra-trace analysis in beer samples using ultra-high performance liquid chromatography-tandem mass spectrometry determination was developed. The factors involved in the efficiency of pretreatment were studied employing factorial design in the screening phase and the optimal conditions of the significant variables on the analytical response were evaluated using a central composite face-centred design (CCF). Consequently, the amount of salt ((NH 4 ) 2 SO 4 ), together with the volumes of sample, hydrophilic (acetone) and nonpolar (toluene) solvents, and times of vortexing and centrifugation were optimized. Under optimized conditions, the limits of detection (LOD) and quantification (LOQ) were 0.02 µg l -1 and 0.08 µg l -1 respectively. OTA extraction recovery by SALLE was approximately 90% (0.2 µg l -1 ). Furthermore, the methodology was in agreement with EU Directive requirements and was successfully applied for analysis of beer samples.

  3. Liquid chromatography-tandem mass spectrometry detection of the quaternary ammonium compound mebezonium as an active ingredient in t61.

    PubMed

    Kirschbaum, Katrin M; Grellner, Wolfgang; Rochholz, Gertrud; Musshoff, Frank; Madea, Burkhard

    2011-03-01

    Quaternary ammonium compounds pose an analytical challenge. Mebezonium, a muscle-relaxing agent contained in veterinary euthanasia solution T61, was analyzed in body fluids, organs, and injection sites of a veterinarian by liquid chromatography-tandem mass spectrometry (LC-MS-MS) method. Additionally, embutramide and tetracaine, which are two other active ingredients contained in T61, methadone, xylazine, and analgesics were detected by LC-MS-MS and high-performance liquid chromatography-ultraviolet detection methods. For detection of mebezonium a solid-phase extraction (SPE) combined with ionpairing reagent heptafluorobutyric acid was developed. Separation was achieved on Phenomenex Synergi Hydro RP C(18) column combined with ammonium formate buffer and acetonitrile (pH 3.5). To enrich other drugs, liquid-liquid extraction procedures were used. Most of these drugs were separated on a Restek Allure PFP Propyl column using the mentioned mobile phase. Mebezonium and embutramide were detected in femoral vein serum in concentrations of 10.9 and 2.0 mg/L, respectively. The concentration of xylazine and methadone in serum was 2.0 and 0.4 mg/L, respectively. The LC-MS-MS method with SPE combined with an ion-pairing reagent allowed the quantitation of mebezonium. Methadone was detected in toxic concentrations and was, in combination with xylazine and T61, considered to be the cause of death.

  4. Validation of a method for simultaneous determination of nitroimidazoles, benzimidazoles and chloramphenicols in swine tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Xia, Xi; Wang, Yuanyuan; Wang, Xia; Li, Yun; Zhong, Feng; Li, Xiaowei; Huang, Yaoling; Ding, Shuangyang; Shen, Jianzhong

    2013-05-31

    This paper presents a sensitive and confirmatory multi-residue method for the analysis of 23 veterinary drugs and metabolites belonging to three classes (nitroimidazoles, benzimidazoles, and chloramphenicols) in porcine muscle, liver, and kidney. After extracted with ethyl acetate and basic ethyl acetate sequentially, the crude extracts were defatted with hexane and further purified using Oasis MCX solid-phase extraction cartridges. Rapid determination was carried out by ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry. Data acquisition was performed under positive and negative mode simultaneously. Recoveries based on matrix-matched calibrations for meat, liver, and kidney ranged from 50.6 to 108.1%. The method quantification limits were in the range of 3-100ng/kg. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. [Analysis of picric acid and picramic acid in water samples by ultra performance hydrophilic interaction chromatography-tandem mass spectrometry].

    PubMed

    Qian, Feizhong; Zhu, Libo; Xu, Nengbin; Feng, Jiayong; Hong, Zhengfang; Xu, Lihong; Chen, Zhongquan; Wang, Shengle

    2014-05-01

    An ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of picric acid and its reductive transformation product picramic acid in aqueous samples. A hydrophilic interaction liquid chromatography (HILIC) column (Acquity UPLC BEH HILIC; 100 mm x 2.1 mm, 1.7 microm) was used for the separation. Surface water samples could be injected into the UPLC system just after being filtered through a 0.2 microm membrane. The satisfactory recoveries of picric acid and picramic acid were in the range of 89% - 107%. Waste water samples were purified by solid phase extraction (SPE), and then were analyzed. The recoveries of picric acid and picramic acid in waste water were 72%-101%. The reproducibility of the method was good with the RSDs of 4.9% - 14.7%. The limits of detection (LODs) of picric acid and picramic acid were 0.1 microg/L and 0.3 microg/L, respectively. This proposed method is rapid, highly specific and suitable for the confirmation and quantitative determination of picric acid and picramic acid in surface water and waste water.

  6. Single Laboratory Validated Method for Determination of Cylindrospermopsin and Anatoxin-a in Ambient Freshwaters by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

    EPA Pesticide Factsheets

    This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.

  7. Determination of caramel colorants' by-products in liquid foods by ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    PubMed

    Goscinny, Séverine; Hanot, Vincent; Trabelsi, Hasna; Van Loco, Joris

    2014-01-01

    2-Methylimidazole, 4-methylimidazole (2-MI and 4-MI), 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl) imidazole (THI) and 5-hydroxymethylfurfural (5-HMF) are neo-formed compounds generated during the manufacture of caramel colours and are transferred to the processed food. These contaminants are known to have a toxicological profile that may pose health risks. Hence, to characterise THI, 2- and 4-MI and 5-HMF levels in liquid foods, an ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and sample preparation was divided into two analytical strategies depending on the concentration range expected in the type of foods targeted. For the determination of the imidazole substitutes (THI, 2- and 4-MI), a sample enrichment and clean-up step by strong cation solid-phase extraction was developed. This method is capable of quantifying over a range of 5 ng ml⁻¹ (LOQ) to 500 ng ml⁻¹ with recoveries of 75.4-112.4% and RSDs of 1.5-15%. For determination of 5-HMF, a standard addition method was applied covering the linear range of 0.25-30 µg ml⁻¹ with RSDs from 2.8% (for intraday precision) to 9.2% (for intermediate precision). The validated analytical methods were applied to 28 liquid food samples purchased from local markets. THI was found only in the beer samples at levels up to 141.2 ng ml⁻¹. For 2-MI, non-quantifiable traces were observed for all samples, while 4-MI was observed in all samples with large concentration variations (from < LOQ to 563.9 ng ml⁻¹). 5-HMF was found at expected concentrations, except for a sherry vinegar sample (113 µg ml⁻¹), which required a high level of dilution before following the standard addition protocol.

  8. Determination of nonylphenol ethoxylate metabolites in vegetables and crops by high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    She, Yongxin; Wang, Jing; Zheng, Yongquan; Cao, Weiqiang; Wang, Rongyan; Dong, Fengshou; Liu, Xingang; Qian, Mingrong; Zhang, Hu; Wu, Liqing

    2012-05-01

    A method has been developed for the simultaneous determination of the concentration of nonylphenol (4-NP), nonylphenol monoethoxylates (NP1EO) and nonylphenol diethoxylates (NP2EO) in vegetables and crops by liquid chromatography-tandem quadrupole mass spectrometry (HPLC-MS/MS). These target compounds were extracted from vegetable and crop samples with acetonitrile, and then the extracts were cleaned using solid phase extraction with graphitised carbon black tandem primary secondary amine (PSA) cartridges. The MS method enabled highly reliable identification by monitoring the corresponding ammonium adduct [M+NH4](+) in the positive mode for NP1EO and NP2EO, and the deprotonated molecule [M-H](-) in the negative mode for 4-NP. Recoveries for the spiked samples ranged from 65% to 118%. The limit of detection (LOD) of 4-NP, NP1EO and NP2EO was 3, 5 and 0.1μgkg(-1), respectively. This method would be useful for the quick and routine detection of the residues of 4-NP, NP1EO and NP2EO in vegetables and crops. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma.

    PubMed

    Kopec, Rachel E; Schweiggert, Ralf M; Riedl, Ken M; Carle, Reinhold; Schwartz, Steven J

    2013-06-30

    Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma

    PubMed Central

    Kopec, Rachel E.; Schweiggert, Ralf M.; Riedl, Ken M.; Carle, Reinhold; Schwartz, Steven J.

    2013-01-01

    Rationale Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. Methods After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. Results For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. Conclusions HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. PMID:23681818

  11. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma.

    PubMed

    Gandhi, Abhishek; Guttikar, Swati; Trivedi, Priti

    2015-10-01

    A sensitive and simultaneous liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C 18 (50 mm×4.6 mm, 2.6 µm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100-20.0 ng/mL for levonorgestrel and 4.00-500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies.

  13. [Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Lech, Rodziewicz; Jolanta, MasŁOwiecka; Anna, Sadowska; Halina, Car

    2017-10-08

    Five thyreostats (TSs), namely tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil, were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in positive electrospray ionization mode. Extraction and clean-up were achieved using a ChemElut cartridge with tert -butyl methyl ether, without a derivatization step. Separation was achieved on an Acquity UPLC SS T3 column. The mobile phase was acetonitrile and water containing 0.2% (v/v) formic acid. The mass spectrometer was operated in multiple reaction monitoring mode. Urine samples were spiked with TS solution at levels corresponding to 5, 10, 15, and 20 μg/L. The accuracy (internal standard corrected) ranged from 92% to 107%, with a repeatability precision (relative standard deviation, RSD) less than 15% for all five analytes. The RSDs within-laboratory reproducibility was less than 26%. The decision limits (CCα) and detection capabilities (CCβ) were obtained from a calibration curve and were in the ranges of 3.1-6.1 μg/L and 4.0-7.4 μg/L, respectively. The CCα and CCβ values were below the recommended concentration, which was set at 10 μg/L. The results show that the described method is suitable for the direct detection of TSs in bovine urine. This method can also be used to determine TSs in porcine urine.

  14. Determination of amphetamine and methamphetamine in umbilical cord using liquid chromatography-tandem mass spectrometry

    PubMed Central

    Jones, Joseph; Rios, Rosemarie; Jones, Mary; Lewis, Douglas; Plate, Charles

    2009-01-01

    The use of meconium as a drug-screening matrix for newborns has been the gold standard of care for the past two decades. A recent study using matched pairs of meconium and umbilical cord demonstrated a high degree of agreement. The use of liquid chromatography-tandem mass spectrometry as a means to confirm amphetamines presumptive positive umbilical cord specimens for amphetamine and methamphetamine is described here for the first time. The limit of detection for both compounds was 0.2 ng/g. The limit of quantitation for both compounds was 0.6 ng/g. The assay was linear for both compounds up to 100 ng/g. PMID:19783234

  15. Quantitative determination of risperidone, paliperidone and olanzapine in human serum by liquid chromatography-tandem mass spectrometry coupled with on-line solid-phase extraction.

    PubMed

    Ruan, Can-Jun; Guo, Wei; Zhou, Miao; Guo, Gui-Xin; Wang, Chuan-Yue; Li, Wen-Biao; de Leon, Jose

    2018-07-01

    A recent guideline recommends therapeutic drug monitoring for risperidone, paliperidone and olanzapine, which are frequently used second-generation antipsychotics. We developed a simple high-performance liquid chromatography-tandem mass spectrometry coupled with an online solid-phase extraction method that can be used to measure risperidone, paliperidone and olanzapine using small (40 μL) samples. The analytes were extracted from serum samples automatically pre-concentrated and purified by C 8 (5 μm, 2.1 × 30 mm) solid-phase extraction cartridges, then chromatographed on an Xbidge™ C 18 column (3.5 μm, 100 × 2.1 mm) thermostatted at 30°C with a mobile phase consisting of 70% acetonitrile and 30% ammonium hydroxide 1% solution at an isocratic flow rate of 0.3 mL/min, and detected with tandem mass spectrometry. The assay was validated in the concentration range from 2.5 to 160 ng/mL. Intra- and inter-day precision for all analytes was between 1.1 and 8.2%; method accuracy was between 6.6 and 7.6%. The risperidone and paliperidone assay was compared with a high-performance liquid chromatography-ultraviolet assay currently used in our hospital for risperidone and paliperidone therapeutic drug monitoring, and the results of weighted Deming regression analysis showed good agreement. For the olanzapine assay, we compared 20 samples in separate re-assays on different days; all the relative errors were within the 20% recommended limit. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Multi-walled carbon nanotubes as solid-phase extraction sorbents for simultaneous determination of type A trichothecenes in maize, wheat and rice by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Dong, Maofeng; Si, Wenshuai; Jiang, Keqiu; Nie, Dongxia; Wu, Yongjiang; Zhao, Zhihui; De Saeger, Sarah; Han, Zheng

    2015-12-04

    A solid-phase extraction (SPE) procedure using multi-walled carbon nanotubes (MWCNTs) as sorbents coupled with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed for simultaneous determination of four type A trichothecenes in maize, wheat and rice for the first time. Several key parameters including the composition of sample loading solutions, washing and elution solvents were thoroughly investigated to achieve optimal SPE recoveries and efficiency. Performance of the MWCNTs materials was significantly affected by pH, and after optimization, n-hexane and 5% methanol aqueous solution as the washing solutions and methanol containing 1% formic acid as the elution solvent presented an excellent purification efficiency for the four targets in the different matrices. The method was validated by determining the linearity (R(2)≥0.992), recovery (73.4-113.7%), precision (1.2-17.1%) and sensitivity (limit of quantification in the range of 0.02-0.10μg/kg), and was further applied for simultaneous determination of type A trichothecenes in 30 samples. Although low contamination levels of type A trichothecenes in wheat, maize and rice were observed revealing mitigated risks to consumers in Shanghai, China, the developed method has proven to be a valuable tool for type A trichothecenes monitoring in complex crop matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. [Determination of 12 flavonoids in tobacco leaves using ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Li, Yong; Lin, Qian; Pang, Tao; Shi, Junli

    2015-07-01

    Flavonoids are very important secondary metabolites for tobacco plants. They are also considered as important flavor precursors for cigarettes. A method of ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was established for the simultaneous determination of 12 flavonoids in tobacco leaves. The developed method determined 10 more flavonoids compared to the traditional method. A solution of methanol-water-chloroform (5:2:2, v/v/v) was used to extract the flavonoids from tobacco leaves and remove the pigment. Instrument analysis using the UPLC-MS/MS was completed in 13 min. The method validation was performed, and the results showed that the linear correlation coefficients (r2) of all the 12 flavonoids were more than 0.99. The limits of detection and the limits of quantification were in the range of 0.3-100 μg/L and 1.2-400 μg/L, respectively. Intra-day and Inter-day reproducibilities were in the range of 3.5%-7.4% and 5.2%-11.4%, respectively. The recoveries were 81.2%-111.9%. The established method was successfully used to analyze the flavonoids of tobacco leaves of 11 varieties. Significant concentration differences of the flavonoids were found among the determined varieties. Furthermore, significant positive correlation among the flavonoids with similar chemical structures (aglycones and their related glycosides, glycosides with the same aglycone, and similar aglycones) was found using the acquired data.

  18. [Determination of di (hydrogenated tallow alkyl) dimethyl ammonium compounds in textile auxiliaries by ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhu, Feng

    2015-01-01

    A method has been developed for the determination of di (hydrogenated tallow alkyl) dimethyl ammonium compounds (DHTDMAC) in textile auxiliaries by ultra-high performance liquid chromatography-tandem mass spectrometry. (UPLC-MS/MS). The samples were extracted and diluted with acidified methanol by 5% (v/v) formic acid under ultrasonic assistance. The separation was performed on an Eclipse Plus C18 column (50 mm x 2.1 mm, 1.8 microm) using 0.1% (v/v) formic acid solution and methanol as the mobile phases. Identification and quantification were achieved by UPLC-MS/MS with electrospray ionization (ESI) source in positive ion mode and multiple reaction monitoring (MRM) mode. The results indicated that the calibration curve of DHTDMAC showed good linear relationship between peak area and mass concentration in the range of 10-280 microg/L with the correlation coefficient (r2) of 0.9991. The limit of detection (LOD, S/N=3) and the limit of quantification (LOQ, S/N= 10) of this method were 3 mg/kg and 10 mg/kg, respectively. The average recoveries from three typical textile auxiliary matrices including dispersant, antistatic agent and fabric softener, at three spiked levels were in the range of 97.2%-108.3% with the relative standard deviations (RSDs) of 1.5%-4.6%. The method is sensitive, accurate, simple and effective for the analysis of DHTDMAC in textile auxiliaries.

  19. Dual ultrasonic-assisted dispersive liquid-liquid microextraction coupled with microwave-assisted derivatization for simultaneous determination of 20(S)-protopanaxadiol and 20(S)-protopanaxatriol by ultra high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Xian-En; Lv, Tao; Zhu, Shuyun; Qu, Fei; Chen, Guang; He, Yongrui; Wei, Na; Li, Guoliang; Xia, Lian; Sun, Zhiwei; Zhang, Shijuan; You, Jinmao; Liu, Shu; Liu, Zhiqiang; Sun, Jing; Liu, Shuying

    2016-03-11

    This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(S)-protopanaxadiol (PPD) and 20(S)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4'-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Aszyk, Justyna; Kubica, Paweł; Kot-Wasik, Agata; Namieśnik, Jacek; Wasik, Andrzej

    2017-10-13

    Liquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI-MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace ® Ultracore™ SuperC18™ (100×2.1mm, 2.5μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple "dilute & shoot" approach was used for the sample preparation. The method validation was performed by evaluating key analytical parameters such as linearity, accuracy, selectivity, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curves showed good linearity within the specific ranges for the investigated compounds with correlation coefficients greater than 0.990 in each case. The recovery for all the investigated compounds varied from 89% to 110%. The intra- and inter-day precision were within the acceptable limits (±15%) at all tested concentrations. The applicability of the methods was examined by analysing 25 liquid samples from e-cigarettes commercially available on the Polish market. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  2. Selective solid-phase extraction based on molecularly imprinted technology for the simultaneous determination of 20 triazole pesticides in cucumber samples using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Fengnian; She, Yongxin; Zhang, Chao; Cao, Xiaolin; Wang, Shanshan; Zheng, Lufei; Jin, Maojun; Shao, Hua; Jin, Fen; Wang, Jing

    2017-10-01

    A selective analytical method for the simultaneous determination of 20 triazole fungicides and plant growth regulators in cucumber samples was developed using solid-phase extraction with specific molecularly imprinted polymers (MIPs) as adsorbents. The MIPs were successfully prepared by precipitation polymerization using triadimefon as the template molecule, methacrylic acid as the functional monomer, trimethylolpropane trimethacrylate as the crosslinker, and acetonitrile as the porogen. The performance and recognition mechanism for both the MIPs and non-molecularly imprinted polymers were evaluated using adsorption isotherms and adsorption kinetics. Liquid chromatography-tandem quadrupole mass spectrometry was used to identify and quantify the target analytes. The solid-phase extraction using the MIPs was rapid, convenient, and efficient for extraction and enrichment of the 20 triazole pesticides from cucumber samples. The recoveries obtained at three concentration levels (1, 2, and 10μgL -1 ) ranged from 82.3% to 117.6% with relative standard deviations of less than 11.8% (n=5) for all analytes. The limits of detection for the 20 triazole pesticides were all less than 0.4μgL -1 , and were sufficient to meet international standards. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Enantioseparation of Imazalil and Monitoring of Its Enantioselective Degradation in Apples and Soils Using Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Li, Runan; Dong, Fengshou; Xu, Jun; Liu, Xingang; Wu, Xiaohu; Pan, Xinglu; Tao, Yan; Chen, Zenglong; Zheng, Yongquan

    2017-04-26

    Imazalil is a widely used systemic chiral fungicide that is still being employed as a racemic mixture without distinguishing the difference between enantiomers, which often leads to its inaccurate risk assessment. In this study, a robust and highly sensitive chiral separation method was developed for imazalil enantiomers by ultrahigh-performance liquid chromatography-tandem mass spectrometry and was further applied to study the degradation dynamics of imazalil enantiomers in apples and field soils at three sites in China. The baseline enantioseparation for imazalil was achieved within 3.5 min on a Lux Cellulose-2 (CCMPC) column with acetonitrile (ACN)/water (65:35, v/v) with a mobile phase at 0.5 mL/min flow rate and a column temperature of 20 °C. The limit of quantitation (LOQ) for each enantiomer was <0.60 μg/kg, with a baseline resolution of approximately 1.75. The research showed that (S)-(+)-imazalil degraded more rapidly than (R)-(-)-imazalil in Gala apples, whereas (R)-(-)-imazalil preferentially degraded in Golden Delicious apples. No significant enantioselectivity was observed in OBIR-2T-47 apples and field soils from the three sites. Results of this study provide useful references for risk assessment and the rational use of imazalil in further agricultural produce practice.

  4. Simple and sensitive determination of hydrazine in drinking water by ultra-high-performance liquid chromatography-tandem mass spectrometry after derivatization with naphthalene-2,3-dialdehyde.

    PubMed

    Oh, Jin-Aa; Shin, Ho-Sang

    2015-05-22

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to determine the level of hydrazine in drinking water. The method is based on the derivatization of hydrazine with naphthalene-2,3-dicarboxaldehyde (NDA) in water. The optimum conditions for UPLC-MS/MS detection were determined as follows: derivatization reagent dosage, 50mg/L of NDA; pH 2; and reaction time, 1min; room temperature. The formed derivative was injected into an LC system without extraction or purification procedures. Under the established conditions, the method was used to detect hydrazine in raw drinking water and chlorinated drinking water. The limits of detection and quantification for hydrazine in drinking water were 0.003μg/L and 0.01μg/L, respectively. The accuracy was in the range of 97-104%, and precision, expressed as relative standard deviation, was less than 9% in drinking water. Hydrazine was detected at a concentration of 0.13μg/L in one sample among 24 raw drinking water samples and in a range of 0.04-0.45μg/L in three samples among 24 chlorinated drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. [Determination of aflatoxin B1, B2, G1, G2 in armeniacae semen amarum by high-performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zheng, Run-Sheng; Xu, Hui; Wang, Wen-Li; Zhan, Ruo-Ting; Chen, Wei-Wen

    2013-10-01

    A simple, rapid and cost-effective high-performance liquid chromatography-tandem mass spectrometry (LC-MS/ MS) method was established for simultaneous determination of aflatoxins (AFB1, AFB2, AFG1, AFG2) in Armeniacae Semen Amarum and the application was performance in 11 samples collected from different markets, medical stores and hospitals. The sample was extracted with 84% acetonitrile/water and 250 microL extraction was directly injected into a LC-MS/MS system without further purification procedure after being redissolved with methanol. The LC separation was performed on a C18 column with a linear gradient elution program of 4 mmol x L(-1) NH4 Ac-0.1% formic acid solution and menthol as the mobile phase. Selected reaction monitoring (SRM) was used for selective determination of the four aflatoxins on a triple quadruple mass spectrometer, which was operated in positive ionization modes. All the four aflatoxins showed a good linear relationship with r > 0.999 0, the average recoveries were between 87.88% and 102.9% and the matrix effect was ranged from 90.71% to 99.30% in low, intermediate and high levels. Furthermore, the higher recovery was obtained by the method reported in this study, comparing to the cleanup procedure with the Mycosep 226 purification column. Eleven samples collected were detected and the contamination levels of the AFB1 were between 1.590-2.340 microg x kg(-1) and the AF (B1 + B2 + G1 + G2) was ranged from 2.340 to 3.340 microg x kg(-1). In summary, the developed method was suitable to detect and screen AFB1, AFB2, AFG1, AFG2 in Armeniacae Semen Amarum.

  6. Ultra high performance liquid chromatography-tandem mass spectrometry vs. commercial immunoassay for determination of vancomycin plasma concentration in children. Possible implications for everyday clinical practice.

    PubMed

    Barco, Sebastiano; Castagnola, Elio; Gennai, Iulian; Barbagallo, Laura; Loy, Anna; Tripodi, Gino; Cangemi, Giuliana

    2016-10-01

    Vancomycin therapeutic drug monitoring (TDM) is necessary for effective and safetherapy. The aim of the this paper was to develop a specific and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for vancomycin quantification starting from low plasma volumes to be applied for the routine TDM in children. Samples from children receiving intravenous vancomycin were analysed using a TSQ Quantum Access MAX Triple Quadrupole system coupled with an Accela 1250 UHPLC system after a rapid protein precipitation. Gradient separation chromatography was carried out using a Hypersil GOLD aQ C18 column (50 × 2.1 mm, particle size 1.9 μm). Method performance was validated following international guidelines. UHPLC-MS/MS allowed a rapid and specific quantification of vancomycin over the range 0.1-128 μg/mL from 50 μL of plasma with high reproducibility and accuracy in the absence of matrix effect. The comparison with the commercial immunoassay performed on 138 samples demonstrated the presence of a proportional bias. The concentrations of vancomycin measured with immunoassay were found to be 4.5% (95% CI: 1.3-7.7) higher than those determined with UHPLC-MS/MS. Importantly, a clinical discordance was found in about 10% of samples analysed. This new UHPLC-MS/MS method is accurate and specific for the measurement of vancomycin starting from small (50 μL) plasma volumes. The use of UHPLC-MS/MS is recommended to prevent a misclassification of therapeutic or toxic vancomycin levels in paediatrics.

  7. [Determination of 11 industrial antioxidants in the aqueous simulants by ultra-performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Fan, Sai; Zou, Jianhong; Li, Liping; Zhang, Nan; Liu, Wei; Li, Bing; Zhao, Xudong; Wu, Guohua; Xue, Ying; Zhao, Rong

    2014-09-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed to identify and determine 11 industrial antioxidants in the aqueous simulants. A ProElut PLS SPE column was used for the enrichment, and an ACQUITY UPLC BEH C18 UPLC column (100 mm x 2.1 mm, 1.7 μm) was used for separation by the gradient elution with pure water and acetonitrile as the mobile phases. The MS/MS detection was performed with an electrospray ionization (ESI) source in negative mode. The external standard method was used for quantitation in the present study. The linear ranges of the 11 analytes were from 5.0 to 100 μg/L. The coefficients of correlation were greater than 0.995. The recoveries of blank aqueous simulants fortified with the 11 analytes at the levels of 5.0, 10.0 and 20.0 μg/L were 61.4% to 109.4% with the relative standard deviations varied from 3.9% to 18.2% (n = 6). The LODs and LOQs of the 11 analytes in aqueous simulants were 0.2-1.0 μg/L and 0.5-3.0 μg/L, respectively. This method is highly sensitive and accurate, and can be applied to the determination of the 11 trace industrial antioxidants in the aqueous simulants.

  8. [Simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Gou, Xinlei; Gao, Xia; Hu, Guanghui; Chi, Haitao; Le, Shengfeng; Wang, Wei; Liu, Weili

    2014-09-01

    A sensitive method was developed for the simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The samples were freeze-dried under vacuum and then dissolved with methanol. The separation was performed on a UPLC BEH C18 column (100 mm x 2.1 mm, 1.7 μm) by using 0.1% (v/v) NH3 · H2O and methanol as mobile phases with gradient elution at a flow rate of 0.2 mL/min. The electrospray ionization (ESI) source in negative ion mode was used for the analysis of the 11 bisphenols in the multiple reaction monitoring (MRM) mode. The results verified that the standard curves for the 11 bisphenols were obtained with good correlation coefficients (R2) > 0.997 in their concentration ranges. The limits of detection (LOD, S/N = 3) for the 11 bisphenols were in the range of 0.01-1.00 μg/L. The mean recoveries for the 11 bisphenols at three spiked levels (low, middle, high) were 75.3%-102.1% with the relative standard deviations of 1.5%-8.9%. Seven plastic bottled drinking water samples were tested, and no bisphenol was found. The method is accurate, simple, rapid and feasible for the simultaneous determination of bisphenols in plastic bottled drinking water.

  9. Quantification of N-acetyl- and N-glycolylneuraminic acids by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario

    2008-11-28

    The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.

  10. A multiresidue approach for the simultaneous quantification of antibiotics in macroalgae by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Leston, Sara; Freitas, Andreia; Rosa, João; Barbosa, Jorge; Lemos, Marco F L; Pardal, Miguel Ângelo; Ramos, Fernando

    2016-10-15

    Together with fish, algae reared in aquaculture systems have gained importance in the last years, for many purposes. Besides their use as biofilters of effluents, macroalgae's rich nutritional profiles have increased their inclusion in human diets but also in animal feeds as sources of fatty acids, especially important for the fish industry. Nonetheless, algae are continuously exposed to environmental contaminants including antibiotics and possess the ability for bioaccumulation of such compounds. Therefore, the present paper describes the development and validation of an ultra-high performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous quantification of antibiotics in the green macroalgae Ulva lactuca. This multi-residue method enables the determination of 38 compounds distributed between seven classes and was fully validated according to EU Decision 2002/657/EC. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. [Determination of triclosan and triclocarban in human breast milk by solid-phase extraction and ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Pin; Zhang, Jing; Shi, Ying; Shao, Bing

    2015-03-01

    An analytical method was developed to simultaneously detect triclosan (TCS) and triclocarban (TCC) in human breast milk using solid-phase extraction (SPE) with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples were extracted by acetonitrile and purified with C -18 SPE cartridge after enzymolysis with β-glucuronidase/arylsulfatase. The chromatographic separation was performed on a Waters ACQUITY UPLC™ HSS T3 column (100 mm x 2. 1 mm, 1. 8 µm) with gradient elution using methanol and water at a flow rate of 0. 3 ml/min. The target analytes were assayed by triple quadrupole mass spectrometer operating in the negative ion mode. Quantification was performed by isotopic internal standard calibration. Satisfactory linearity (r2 > 0. 999) was obtained over the range of 0. 2 - 20. 0 µg/L and 0. 02 - 2. 0 µg/L for triclosan and triclocarban, respectively, with the limits of quantifications (LOQs) of 0. 41 and 0. 03 µg/kg. Average recoveries of two target compounds (spiked at three concentration levels) ranged from 100. 2% to 119. 3%, with the relative standard deviations (RSDs) between 5. 91% and 11. 31% (n =6). Twenty-five real samples (n = 25) were detected containing TCS and TCC at concentrations of < LOQ - 0. 77 µg/kg and < LOQ - 4. 28 µg/kg, respectively. Due to its high sensitivity and good reproductivity, this method can be applied to analyze TCS and TCC in human breast milk.

  12. A selective biomarker for confirming nitrofurazone residues in crab and shrimp using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Shuai; Guo, Yuanming; Yan, Zhongyong; Sun, Xiumei; Zhang, Xiaojun

    2015-12-01

    Reliably detecting nitrofurazone (NFZ) residues in farmed crab and shrimp was previously hindered by lack of appropriately specific analytical methodology. Parent NFZ rapidly breaks down in meat, and the commonly used side-chain metabolite, semicarbazide (SEM), is non-specific as it occurs naturally in crustacean shell often leading to 'false positive' detections in meat. Using 5-nitro-2-furaldehyde (NF) as marker metabolite, following pre-column derivatization with 2,4-dinitrophenylhydrazine (DNPH), ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis in negative electrospray ionization mode enabled confirmation of NFZ residues in deliberately treated whole crab, crab meat and shrimp meat, with a limit of detection (LOD) and limit of quantification (LOQ) below 1 ng g(-1). Meanwhile, the derivatives of DNPH-NF were synthesized for the first time, purified by preparative liquid chromatography and structure characterized with nuclear magnetic resonance spectroscopy ((1)H-NMR). The purity of derivative was checked by ultra-performance liquid chromatography-tunable ultraviolet (UPLC-TUV), and the contents were beyond 99.9%. For comparison purposes, crustacean samples were analysed using both NF and SEM marker metabolites. NFZ treatment was revealed by both NF and SEM marker metabolites, but untreated crab also showed measurable levels of SEM which could potentially be misinterpreted as evidence of illegal NFZ use.

  13. Development and validation of LC-MS/MS methods for the determination of mirabegron and its metabolites in human plasma and their application to a clinical pharmacokinetic study.

    PubMed

    Teijlingen, Raymond van; Meijer, John; Takusagawa, Shin; Gelderen, Marcel van; Beld, Cas van den; Usui, Takashi

    2012-03-01

    Mirabegron is being developed for the treatment of overactive bladder. To support the development of mirabegron, including pharmacokinetic studies, liquid chromatography/tandem mass spectrometry methods for mirabegron and eight metabolites (M5, M8, M11-M16) were developed and validated for heparinized human plasma containing sodium fluoride. Four separate bioanalytical methods were developed for the analysis of: (1) mirabegron; (2) M5 and M16; (3) M8; and (4) M11-M15. Either solid-phase extraction or liquid-liquid extraction was used to extract the analytes of interest from matrix constituents. For mirabegron, an Inertsil C₈-3 analytical column was used and detection was performed using a triple-quad mass spectrometer equipped with an atmospheric pressure chemical ionization interface. For the metabolite assays, chromatographic separation was performed through a Phenomenex Synergi Fusion-RP C₁₈ analytical column and detection was performed using a triple-quad mass spectrometer equipped with a Heated Electrospray Ionization interface. The validation results demonstrated that the developed liquid chromatography/tandem mass spectrometry methods were precise, accurate, and selective for the determination of mirabegron and its metabolites in human plasma. All methods were successfully applied in evaluating the pharmacokinetic parameters of mirabegron and metabolites in human plasma. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Direct large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry determination of artificial sweeteners sucralose and acesulfame in well water.

    PubMed

    Wu, Minghuo; Qian, Yichao; Boyd, Jessica M; Hrudey, Steve E; Le, X Chris; Li, Xing-Fang

    2014-09-12

    Acesulfame (ACE) and sucralose (SUC) have become recognized as ideal domestic wastewater contamination indicators. Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) analysis is commonly used; however, the sensitivity of SUC is more than two orders of magnitude lower than that of ACE, limiting the routine monitoring of SUC. To address this issue, we examined the ESI behavior of both ACE and SUC under various conditions. ACE is ionic in aqueous solution and efficiently produces simple [M-H](-) ions, but SUC produces multiple adduct ions, limiting its sensitivity. The formic acid (FA) adducts of SUC [M+HCOO](-) are sensitively and reproducibly generated under the LC-MS conditions. When [M+HCOO](-) is used as the precursor ion for SUC detection, the sensitivity increases approximately 20-fold compared to when [M-H](-) is the precursor ion. To further improve the limit of detection (LOD), we integrated the large volume injection approach (500μL injection) with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), which reduced the method detection limit (MDL) to 0.2ng/L for ACE and 5ng/L for SUC. To demonstrate the applicability of this method, we analyzed 100 well water samples collected in Alberta. ACE was detected in 24 wells at concentrations of 1-1534ng/L and SUC in 8 wells at concentrations of 65-541ng/L. These results suggest that wastewater is the most likely source of ACE and SUC impacts in these wells, suggesting the need for monitoring the quality of domestic well water. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. [Simultaneous determination of seven high risk pesticide residues in royal jelly by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Li, Yinghong; Zhou, Ping; Xu, Quanhua; Zhao, Huan; Shao, Qiaoyun

    2018-02-08

    A method was developed for the simultaneous determination of seven high risk pesticides in the royal jelly, eg. tau-fluvalinate, triadimenol, coumaphos, haloxyfop, carbendazim, thiophanate-ethyl and thiophanate-methyl by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). First, the royal jelly samples were extracted with acetonitrile under alkaline conditions. After dehydration by anhydrous sodium sulfate, the extracts were enriched and purified through solid-phase extraction (SPE) with Oasis HLB cartridges. Finally, the pesticides were detected by HPLC-MS/MS method. The separation was carried out on a Venusil MP C18 column with gradient elution. Methanol (containing 0.1% (v/v) formic acid) and 0.5 mmol/L ammonium acetate aqueous solution (containing 0.1% (v/v) formic acid) were used as the mobile phases. The detection was achieved using electrospray ionization in positive ion (ESI + ) mode and multiple reaction monitoring (MRM) mode for data collection. Quantification was carried out using internal standard method. The results showed that the seven high risk pesticides were linear in the range of 5-100 μg/kg. The linear correlation coefficients ( r 2 ) were 0.9921-0.9996. The limits of detection (LODs) and limits of quantification (LOQs) of the seven high risk pesticides were 0.5-2.0 μg/kg and 1.0-5.0 μg/kg, respectively. The average recoveries at the three spiked levels were 80.5%-101.3%, and the relative standard deviations were 3.6%-9.4% ( n =3). This method is simple, effective and sensitive, and is suitable for the determination of the pesticide residues in royal jelly.

  16. [Simultaneous determination of delta-9-tetrahydrocannabinol cannabidiol and cannabinol in edible oil using ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Aizhi; Wang, Quanlin; Mo, Shijie

    2010-11-01

    A method for the simultaneous determination of delta-9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in edible oil was developed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with methanol, purified by an LC-Alumina-N solid phase extraction cartridge, separated and detected by the UPLC-MS/MS. Quantitative analysis was corrected by an isotope internal standard method using delta-9-THC-D3 as internal standard. Average recoveries for the target compounds varied from 68.0% to 101.6% with the relative standard deviations ranging from 7.0% to 20.1% at three spiked levels. The limits of detection (LOD) of the method were from 0.06-0.17 microg/kg and the limits of quantification (LOQ) were in the range of 0.20-0.52 microg/kg. The results showed that the method is able to meet the requirements for the simultaneous determination of THC, CBD and CBN in edible oil.

  17. Ultra-high-performance liquid chromatography/tandem high-resolution mass spectrometry analysis of sixteen red beverages containing carminic acid: identification of degradation products by using principal component analysis/discriminant analysis.

    PubMed

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Marengo, Emilio

    2015-01-15

    The study investigates the sunlight photodegradation process of carminic acid, a natural red colourant used in beverages. For this purpose, both carminic acid aqueous standard solutions and sixteen different commercial beverages, ten containing carminic acid and six containing E120 dye, were subjected to photoirradiation. The results show different patterns of degradation, not only between the standard solutions and the beverages, but also from beverage to beverage. Due to the different beverage recipes, unpredictable reactions take place between the dye and the other ingredients. To identify the dye degradation products in a very complex scenario, a methodology was used, based on the combined use of principal component analysis with discriminant analysis and ultra-high-performance liquid chromatography coupled with tandem high resolution mass spectrometry. The methodology is unaffected by beverage composition and allows the degradation products of carminic acid dye to be identified for each beverage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. [Simultaneous determination of 16 flavonoids in the ginkgo dietary supplement tea by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Jiang, Yalan; Huang, Fang; Wu, Fuhai; Wu, Huiqin; Huang, Xiaolan; Deng, Xin

    2015-10-01

    A method for the determination of 16 functional components of ginkgo dietary supplement tea such as catechin, vitexin, puerarin, isoflavoues aglycone, silymarin, quercetin, luteolin, apigenin, naringenin, hesperitin dihydrochalcone, kaempferol, hesperitin, isorhamnetin, baicalein, nobiletin and tangeretin by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was proposed. The conditions of chromatography and mass spectrometry were optimized. The 16 flavonoids were separated on a C18 chromatographic column with acetonitrile and water (additional 0.1% formic acid) as mobile phases under gradient elution at a flow rate of 0.25 mL/min. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. Good linearities for all the compounds, with correlation coefficients over 0.996, were acquired. The recoveries were in the range of 70.9% to 100.0% (n = 6), while the relative standard deviations (RSDs) were less than 10%. The results showed that the nine flavonoids, which were kaempferol, quercetin, hesperitin, vitexin, luteolin, catechin, apigenin, naringenin and isorhamnetin, were higher in contents among the 16 flavonoids in real samples, and they constituted up to 99.6% of the total flavonoids. The contents of these nine flavonoids can be considered as the quality control index of the ginkgo dietary supplement tea. The method proved to be rapid, selective, sensitive and stable, and it can be applied to control the quality of the ginkgo dietary supplement tea.

  19. Determination of naphthalene-derived compounds in apples by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Esparza, X; Moyano, E; Cosialls, J R; Galceran, M T

    2013-06-11

    Naphthylacetic acid, naphthyloxy acetic acid and naphthylacetamide belong to a group of synthetic substances known as "auxin-like" compounds which are used as growth regulators in vegetables and fruits due to their structure similarities with the indoleacetic acid, the most important plant auxin. This paper reports a selective, sensitive and fast ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the determination of naphthylacetamide (NAD) and the isomers (α and β) of naphthylacetic acid (NAA) and naphthyloxy acetic (NOA) acid in apple samples. A baseline separation between the respective isomers was achieved using an RP-Amide column with gradient elution. The UHPLC-MS/MS method developed, using electrospray and selected reaction monitoring (SRM) acquisition mode led to a reliable determination of these family of compounds in apple samples at low quantitation levels, down to 1.0 μg kg(-1) and 0.25 μg kg(-1) respectively. For confirmation of NAA accurate mass measurement is proposed giving at these conditions quantitation limits of 10 μg kg(-1) for this compound. The UHPLC-MS/MS method developed was used for the analysis of apple samples harvested in three different apple fields from Lleida (Spain) during the blooming period. NAD and NAA were found in samples collected during 4-5 weeks after application at concentrations between the quantification limits and 43 μg kg(-1) and 24 μg kg(-1), respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. [Simultaneous determination of 6 pesticides in drinking water by high performance liquid chromatography-tandem mass spectrometry with solid phase extraction].

    PubMed

    Liu, Hua-liang; Wang, Lian-hong

    2013-05-01

    To develop an analytical method for simultaneous determination of 6 pesticides, namely bentazone, 2,4-dichlorophenoxyacetic acid,carbofuran, carbaryl, atrazine and pentachlorophenol, in drinking water by high performance liquid chromatography-tandem mass spectrometry, and thereby to provide a reference to revise the Health Standards for Drinking Water (GB/T 5750-2006). Meanwhile, to evaluate the content of the above 6 pesticides in the drinking water samples supplied by 12 centralized water plants in Jiangsu province. The 10 ml water sample was acidized by hydrochloric acid to pH ≤ 2, and then concentrated by solid phase extraction cartridge and eluted with acetone. The solvent was changed into methanol after drying by nitrogen blow. The target compounds were separated by C18 column using methanol/water as mobile phase, and detected by mass spectrometry with multi-reaction-monitoring(MRM) mode. The repeatability and sensitivity of the assay were evaluated. The drinking water samples from the 12 water plants were then detected. In this experimental method, the minimum detectable concentration were around 0.02-0.41 µg/L, with the recovery rate at 75%-115%, and the RSD between 2% and 10%. Under the experimental condition, there were no pesticides detected in the drinking water samples from the 12 centralized water plants. The method is efficient and environment-friendly, with little discharge of effluent, which could meet the requirement of the drinking water monitor.

  1. Study on dissolution mechanism of cortisol and cortisone from hair matrix with liquid chromatography-tandem mass spectrometry.

    PubMed

    Xing, Xue; Chen, Zheng; Li, Jifeng; Zhang, Jing; Deng, Huihua; Lu, Zuhong

    2013-06-05

    Hair cortisol has been used as a biomarker of chronic stress. The detected contents of hair cortisol might depend on the incubation duration in solvents for no-milled hair samples with 3-layer structure. However, there was no research on the dissolution mechanism of hair analytes. After uniform mixture, no-milled hair samples were incubated in methanol and water for the 12 different durations and milled hair was done as comparison. Hair cortisol and cortisone were determined with high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The measured concentrations of hair cortisol and cortisone showed ≥2 maxima during the entire incubation in methanol and water from 5 min to 72 h for no-milled hair. Hair cortisol concentration measured by LC-MS/MS was increased with the incubation duration. Conversely, it was not held when hair was powdered prior to the incubation in methanol. Hair cortisol and cortisone were dissolved from hair matrix through the 2-stage or multistage mechanism, which might depend on the hair 3-layer structure and its degree of damage. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Simultaneous and rapid determination of gefitinib, erlotinib and afatinib plasma levels using liquid chromatography/tandem mass spectrometry in patients with non-small-cell lung cancer.

    PubMed

    Hayashi, Hideki; Kita, Yutaro; Iihara, Hirotoshi; Yanase, Koumei; Ohno, Yasushi; Hirose, Chiemi; Yamada, Maya; Todoroki, Kenichiro; Kitaichi, Kiyoyuki; Minatoguchi, Shinya; Itoh, Yoshinori; Sugiyama, Tadashi

    2016-07-01

    A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid-phase extraction procedure with tert-butyl methyl ether. The three drugs were separated by high-performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05-100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall-cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC-MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Quantification of citalopram or escitalopram and their demethylated metabolites in neonatal hair samples by liquid chromatography-tandem mass spectrometry.

    PubMed

    Frison, Giampietro; Favretto, Donata; Vogliardi, Susanna; Terranova, Claudio; Ferrara, Santo Davide

    2008-08-01

    Citalopram and escitalopram are highly selective serotonin reuptake inhibitors widely used in the treatment of depression. They exhibit adverse drug reactions and side effects, however, and the development of specific methods for their determination is of great interest in clinical and forensic toxicology. A liquid chromatography-tandem mass spectrometry method has been developed and validated for the assay of citalopram, escitalopram, and their demethylated metabolites in 10-mg hair samples. The analytes were extracted by incubation in methanol and liquid/liquid extraction with diethyl ether/dichloromethane. Gradient elution on a narrow bore C18 column was realized using clomipramine-d3 as an internal standard. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method exhibited a linear range of 25 to 2000 pg/mg, a quantification limit of 25 pg/mg for all analytes, relative standard deviations in the range of 12.10 to 9.80 (intraassay), and 13.80 to 11.78 (interassay), and accuracies (as percent recovery of the spiked standards) in the range of 90% to 110%; it was applied to the determination of citalopram and escitalopram and their metabolites in hair samples of two newborns to document their in utero exposure to the drugs. The method proved suitable for neonatal hair analysis of citalopram or escitalopram and was applied to two real cases of gestational exposure.

  4. Simultaneous determination of polycyclic musks in blood and urine by solid supported liquid-liquid extraction and gas chromatography-tandem mass spectrometry.

    PubMed

    Liu, Hongtao; Huang, Liping; Chen, Yuxin; Guo, Liman; Li, Limin; Zhou, Haiyun; Luan, Tiangang

    2015-06-15

    A rapid, precise and accurate method for the simultaneous determination of 5 polycyclic musks (PCMs) in biological fluids was developed by solid supported liquid-liquid extraction (SLE) coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS). All parameters influencing SLE-GC-MS performance, including electron energy of electron-impact ionization source, collision energy for tandem mass spectrometer when operated in selected-reaction monitoring (SRM) mode, type and volume of elution reagent, nitrogen evaporation time, pH and salinity of sample have been carefully optimized. Eight milliliter of n-hexane was finally chosen as elution reagent. Blood and urine sample could be loaded into SLE cartridge without adjusting pH and salinity. Deuterated tonalide (AHTN-d3) was chosen as internal standard. The correlation coefficient (r(2)) of the calibration curves of target compounds ranged from 0.9996 to 0.9998. The dynamic range spanned over two orders of magnitude. The limit of detection (LOD) of target compounds in blood and urine ranged from 0.008 to 0.105μgL(-1) and 0.005 to 0.075μgL(-1), respectively. The developed procedure was successfully applied to the analysis of PCMs in human blood and urine obtaining satisfying recoveries on low, medium and high levels. The method was compared with SLE-GC-MS and shown one to two orders of magnitude improvement in sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Simultaneous determination of amlodipine and bisoprolol in rat plasma by a liquid chromatography/tandem mass spectrometry method and its application in pharmacokinetic study.

    PubMed

    Chang, Huichao; Li, Jinyin; Li, Ji; Guan, Xiaoduo; Sun, Fanlu; Qian, Zhongzhi; Bi, Kaishun; Fan, Guorong

    2012-12-01

    A sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established for the quantitative determination of amlodipine and bisoprolol, using clenbuterol as the internal standard (IS). The analytes and IS were isolated from 100μL plasma samples by a simple liquid-liquid extraction (LLE). Reverse-phase high performance liquid chromatography (RP-HPLC) separation was accomplished on a Diamonsil C(18) column (50mm×4.6mm, 5μm) with a mobile phase composed of methanol-water-formic acid (75:25:0.01, v/v/v) at a flow rate of 0.3mL/min. The method had a chromatographic total run time of 3min. Multiple reacting monitoring (MRM) transitions of m/z [M+H](+) 409.1→237.9 (amlodipine), m/z [M+H](+) 326.2→116.0 (bisoprolol) and m/z [M+H](+) 277.0→203.0 (clenbuterol, IS) were used to quantify amlodipine, bisoprolol and IS, respectively. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.2ng/mL for both amlodipine and bisoprolol, and the linear range was 0.2-50ng/mL for both amlodipine and bisoprolol (r(2)>0.9961). All the validation data, such as accuracy, precision and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic studies of amlodipine and bisoprolol in Sprague-Dawley (SD) rats. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Determination of artificial sweeteners in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Ordóñez, Edgar Y; Quintana, José Benito; Rodil, Rosario; Cela, Rafael

    2012-09-21

    The development and performance evaluation of an analytical method for the determination of six artificial sweeteners in environmental waters using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry are presented. To this end, different SPE alternatives have been evaluated: polymeric reversed-phase (Oasis HLB, Env+, Plexa and Strata X), and mixed-mode with either weak (Oasis WAX) or strong anionic-exchange (Oasis MAX and Plexa PAX) sorbents. Among them, reversed-phase sorbents, particularly Oasis HLB and Strata X, showed the best performance. Oasis HLB provided good trueness (recoveries: 73-112%), precision (RSD<10%) and limits of quantification (LOQ: 0.01-0.5 μg/L). Moreover, two LC separation mechanisms were evaluated: reversed-phase (RPLC) and hydrophilic interaction (HILIC), with RPLC providing better performance than HILIC. The final application of the method showed the presence of acesulfame, cyclamate, saccharin and sucralose in the wastewater and surface water samples analyzed at concentrations up to 54 μg/L. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Using a single tablet daily to treat latent tuberculosis infection in Brazil: bioequivalence of two different isoniazid formulations (300 mg and 100 mg) demonstrated by a sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry method in a randomised, crossover study.

    PubMed

    Daher, André; Pitta, Luciana; Santos, Tereza; Barreira, Draurio; Pinto, Douglas

    2015-06-01

    The recommended treatment for latent tuberculosis (TB) infection in adults is a daily dose of isoniazid (INH) 300 mg for six months. In Brazil, INH was formulated as 100 mg tablets. The treatment duration and the high pill burden compromised patient adherence to the treatment. The Brazilian National Programme for Tuberculosis requested a new 300 mg INH formulation. The aim of our study was to compare the bioavailability of the new INH 300 mg formulation and three 100 mg tablets of the reference formulation. We conducted a randomised, single dose, open label, two-phase crossover bioequivalence study in 28 healthy human volunteers. The 90% confidence interval for the INH maximum concentration of drug observed in plasma and area under the plasma concentration vs. time curve from time zero to the last measurable concentration "time t" was 89.61-115.92 and 94.82-119.44, respectively. The main limitation of our study was that neither adherence nor the safety profile of multiple doses was evaluated. To determine the level of INH in human plasma, we developed and validated a sensitive, simple and rapid high-performance liquid chromatography-tandem mass spectrometry method. Our results showed that the new formulation was bioequivalent to the 100 mg reference product. This finding supports the use of a single 300 mg tablet daily strategy to treat latent TB. This new formulation may increase patients' adherence to the treatment and quality of life.

  8. Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of atypical antipsychotics and some metabolites in in vitro samples.

    PubMed

    Li, Kun-Yan; Zhou, Yan-Gang; Ren, Hua-Yi; Wang, Feng; Zhang, Bi-Kui; Li, Huan-De

    2007-05-01

    The ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed to perform the determination of quetiapine, perospirone, aripiprazole and quetiapine sulfoxide in in vitro samples in less than 3 min. The UPLC separation was carried out using an Acquity UPLC BEH C18 column (100 mm x 2.1mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to a Waters Micromass Quattro Premier XE tandem quadrupole mass spectrometer. This system permits high-speed data acquisition without peak intensity degradation, and produces sharp and narrow chromatographic peaks (w(h) about 2.5s) of compounds. The determination was performed in multiple reaction monitoring (MRM) mode. The quantification parameters of the developed method were established, obtaining instrumental LODs lower than 0.005 microg/l and a repeatability at a low concentration level lower than 10% CV (n=10). Finally, the method was successfully applied to the analysis of atypical antipsychotics and some metabolites in in vitro samples.

  9. Analysis of potential migrants from plastic materials in milk by liquid chromatography-mass spectrometry with liquid-liquid extraction and low-temperature purification.

    PubMed

    Bodai, Zsolt; Szabó, Bálint Sámuel; Novák, Márton; Hámori, Susanne; Nyiri, Zoltán; Rikker, Tamás; Eke, Zsuzsanna

    2014-10-15

    A simple and fast analytical method was developed for the determination of six UV stabilizers (Cyasorb UV-1164, Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, and Tinuvin 1577) and five antioxidants (Irgafos 168, Irganox 1010, Irganox 3114, Irganox 3790, and Irganox 565) in milk. For sample preparation liquid-liquid extraction with low-temperature purification combined with centrifugation was used to remove fats, proteins, and sugars. After the cleanup step, the sample was analyzed with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). External standard and matrix calibrations were tested. External calibration proved to be acceptable for Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, Irganox 3114, and Irganox 3790. The method was successfully validated with matrix calibration for all compounds. Method detection limits were between 0.25 and 10 μg/kg. Accuracies ranged from 93 to 109%, and intraday precisions were <13%.

  10. Liquid chromatography-tandem mass spectrometry method for determination of panel of neurotransmitters in cerebrospinal fluid from the rat model for tauopathy.

    PubMed

    Kovac, Andrej; Somikova, Zuzana; Zilka, Norbert; Novak, Michal

    2014-02-01

    Alzheimer's disease (AD) is still being recognized today as an unmet medical need. Currently, there is no cure and early preclinical diagnostic assay available for AD. Therefore much attention is now being directed at the development of novel methods for quantitative determination of AD biomarkers in the cerebrospinal fluid (CSF). Here, we describe the liquid chromatography-tandem mass spectrometry method for determination of 5-hydroxytryptamine (SER), 5-hydroxyindoleacetic acid (5-HIAA), homovanilic acid (HVA), noradrenaline (NADR), adrenaline (ADR), dopamine (DA), glutamic acid (Glu), γ-aminobutyric acid (GABA), 3,4-dihydroxyphenylacetic acid (DOPAC) and histamine (HIS) in cerebrospinal fluid (CSF) from the rat model for human tauopathy. The benzoyl chloride was used as pre-column derivatization reagents. Neurotransmitters and metabolites were analysed on ultra performance liquid chromatography (UPLC) on C18 column in combination with tandem mass spectrometry. The method is simple, highly sensitive and showed excellent linearity with regression coefficients higher than 0.99. The accuracy was in a range of 93-113% for all analytes. The inter-day precision (n=5 days), expressed as %RSD, was in a range 2-10% for all analytes. Using this method we detected significant changes of CSF levels of two important neurotransmitters/metabolites, ADR and 5-HIAA, which correlates with progression of neurodegeneration in our animal model. © 2013 Published by Elsevier B.V.

  11. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    PubMed

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Determination of artificial sweeteners in beverages with green mobile phases and high temperature liquid chromatography-tandem mass spectrometry.

    PubMed

    Ordoñez, Edgar Y; Rodil, Rosario; Quintana, José Benito; Cela, Rafael

    2015-02-15

    A new analytical procedure involving the use of water and a low percentage of ethanol combined to high temperature liquid chromatography-tandem mass spectrometry has been developed for the determination of nine high-intensity sweeteners in a variety of drink samples. The method permitted the analysis in 23min (including column reequilibration) and consuming only 0.85mL of a green organic solvent (ethanol). This methodology provided limits of detection (after 50-fold dilution) in the 0.05-10mg/L range, with recoveries (obtained from five different types of beverages) being in the 86-110% range and relative standard deviation values lower than 12%. Finally, the method was applied to 25 different samples purchased in Spain, where acesulfame and sucralose were the most frequently detected analytes (>50% of the samples) and cyclamate was found over the legislation limit set by the European Union in a sample and at the regulation boundary in three others. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish.

    PubMed

    Yang, Xianli; Zhou, Lei; Tan, Yanglan; Shi, Xizhi; Zhao, Zhiyong; Nie, Dongxia; Zhou, Changyan; Liu, Hong

    2017-06-29

    In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1-4) and the N -sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v / v ) with 0.1% formic and purified by dispersive solid-phase extraction (dSPE) with C18 silica and acidic alumina. Qualitative and quantitative detection for the target toxins were conducted under the multiple reaction monitoring (MRM) mode by using the positive electrospray ionization (ESI) mode after chromatographic separation on a TSK-gel Amide-80 HILIC column with water and acetonitrile. Matrix-matched calibration was used to compensate for matrix effects. The established method was further validated by determining the linearity ( R ² ≥ 0.9900), average recovery (81.52-116.50%), sensitivity (limits of detection (LODs): 0.33-5.52 μg·kg -1 ; limits of quantitation (LOQs): 1.32-11.29 μg·kg -1 ) and precision (relative standard deviation (RSD) ≤ 19.10%). The application of this proposed approach to thirty shellfish samples proved its desirable performance and sufficient capability for simultaneous determination of multiclass PSP toxins in sea foods.

  14. Determination of multiple mycotoxins in dietary supplements containing green coffee bean extracts using ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS).

    PubMed

    Vaclavik, Lukas; Vaclavikova, Marta; Begley, Timothy H; Krynitsky, Alexander J; Rader, Jeanne I

    2013-05-22

    An ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the determination of 34 mycotoxins in dietary supplements containing green coffee bean (GCB) extracts was developed, evaluated, and used in the analysis of 50 commercial products. A QuEChERS-like procedure was used for isolation of target analytes from the examined matrices. Average recoveries of the analytes were in the range of 75-110%. The precision of the method expressed as relative standard deviation was below 12%. Limits of detection (LODs) and limits of quantitation (LOQs) ranged from 1.0 to 50.0 μg/kg and from 2.5 to 100 μg/kg, respectively. Due to matrix effects, the method of standard additions was used to ensure accurate quantitation. Ochratoxin A, ochratoxin B, fumonisin B1 and mycophenolic acid were found in 36%, 32%, 10%, and 16% of tested products, respectively. Mycotoxins occurred in the following concentration ranges: ochratoxin A, <1.0-136.9 μg/kg; ochratoxin B, <1.0-20.2 μg/kg; fumonisin B1, <50.0-415.0 μg/kg; mycophenolic acid, <5.0-395.0 μg/kg. High-resolution mass spectrometry operated in full MS and MS/MS mode was used to confirm the identities of the reported compounds.

  15. 77 FR 67282 - Dinotefuran; Pesticide Tolerances for Emergency Exemptions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method is available. For the determination of residues of dinotefuran only, an HPLC/ultraviolet (UV) detection method is available. For the determination of only the metabolites (DN and UF), HPLC/MS and HPLC/MS/MS methods are available. These methods...

  16. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    PubMed

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Multiple analyte adduct formation in liquid chromatography-tandem mass spectrometry - Advantages and limitations in the analysis of biologically-related samples.

    PubMed

    Dziadosz, Marek

    2018-05-01

    Multiple analyte adduct formation was examined and discussed in the context of reproducible signal detection in liquid chromatography-tandem mass spectrometry applied in the analysis of biologically-related samples. Appropriate infusion solutions were prepared in H 2 O/methanol (3/97, v/v) with 1 mM sodium acetate and 10 mM acetic acid. An API 4000 QTrap tandem mass spectrometer was used for experiments performed in the negative scan mode (-Q1 MS) and the negative enhanced product ion mode (-EPI). γ‑Hydroxybutyrate and its deuterated form were used as model compounds to highlight both the complexity of adduct formation in popular mobile phases used and the effective signal compensation by the application of isotope-labelled analytes as internal standards. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Simultaneous detection of diagnostic biomarkers of alkaptonuria, ornithine carbamoyltransferase deficiency, and neuroblastoma disease by high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Hsu, Wei-Yi; Chen, Ching-Ming; Tsai, Fuu-Jen; Lai, Chien-Chen

    2013-05-01

    Urinary homovanillic acid (HVA)/vanillylmandelic acid (VMA), orotic acid (OA), and homogentisic acid (HGA) are diagnostic biomarkers of neuroblastoma, ornithine carbamoyl transferase deficiency (OCTD), and alkaptonuria (AKU), respectively. In this study, a high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous quantification of HVA, VMA, OA, and HGA in urine. After sample preparation, which involved only the dilution procedure, samples were quantified by LC-MS/MS. Full-scan MS/MS mode enabled the urinary markers to be quantified with a high degree of specificity and sensitivity. Rather than using a separate enzymatic method to normalize the concentration of creatinine in urine, we quantified the level of creatinine in urine in one LC-MS run. The limits of detection were 10 μg/l for HGA, 25 μg/l for HVA/VMA, and 50 μg/l for OA with a single-to-noise ratio of 3; the limits of quantification were 50 μg/l for HVA and HGA, 100 μg/l for VMA, and 250 μg/l for OA. The linear dynamic range for quantification of the analytes covered 2 to 3 orders of magnitude, depending on the analyte. The relative standard deviation of the developed LC-MS/MS method was less than 4% for the intra-day validation and 10% for the inter-day validation. The results show that our LC-MS/MS technique is a highly sensitive and rapid method for screening for biomarkers that are diagnostic of three metabolic diseases. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Development of analyses by high-performance liquid chromatography and liquid chromatography/tandem mass spectrometry of bilberry (Vaccinium myrtilus) anthocyanins in human plasma and urine.

    PubMed

    Cooke, Darren N; Thomasset, Sarah; Boocock, David J; Schwarz, Michael; Winterhalter, Peter; Steward, William P; Gescher, Andreas J; Marczylo, Timothy H

    2006-09-20

    Anthocyanins are potent antioxidants that may possess chronic disease preventive properties. Here, rapid, reliable, and reproducible solid-phase extraction, high-performance liquid chromatography (HPLC), and mass spectrometry techniques are described for the isolation, separation, and identification of anthocyanins in human plasma and urine. Recoveries of cyanidin-3-glucoside (C3G) were 91% from water, 71% from plasma, and 81% from urine. Intra- and interday variations for C3G extraction were 9 and 9.1% in plasma and 7.1 and 9.1% in urine and were less than 15% for all anthocyanins from a standardized bilberry extract (mirtoselect). Analysis of mirtoselect by HPLC with UV detection produced spectra with 15 peaks compatible with anthocyanin components found in mirtoselect within a total run time of 15 min. Chromatographic analysis of human urine obtained after an oral dose of mirtoselect yielded 19 anthocyanin peaks. Mass spectrometric analysis employing multiple reaction monitoring suggests the presence of unchanged anthocyanins and anthocyanidin glucuronide metabolites.

  20. Mycotoxins, pesticides and toxic metals in commercial spices and herbs.

    PubMed

    Reinholds, Ingars; Pugajeva, Iveta; Bavrins, Konstantins; Kuckovska, Galina; Bartkevics, Vadims

    2017-03-01

    A total of 300 samples representing six condiments (black pepper, basil, oregano, nutmeg, paprika, and thyme) were analysed for 11 mycotoxins, 134 pesticides and 4 heavy metals by ultra-high performance liquid chromatography-tandem quadrupole mass spectrometry and inductively coupled plasma mass spectrometry. Mycotoxins were detected in 4%, 10% and 30% of all nutmeg, basil and thyme samples, respectively. The residues of 24 pesticides were detected in 59% of the analysed condiments. The maximum residue levels of pesticides were exceeded in 10% of oregano and 46% of thyme samples. A risk assessment of heavy metals was performed, indicating daily intake levels far below the tolerable intake levels.

  1. Simultaneous Determination of 13 Anticoagulant Rodenticidesin Human Blood by Liquid Chromatography-Tandem Mass Spectrometry and its Application in Three Poisoning Cases.

    PubMed

    Qiao, Zheng; Xiang, Ping; Shen, Baohua; Shen, Min; Yan, Hui

    2018-05-01

    Anticoagulant rodenticides are widely used for rodent control around the world. A rapid and sensitive method was developed and validated for the simultaneous determination of 13 anticoagulant rodenticides (coumafuryl, pindone, valone, warfarin, coumatetralyl, coumachlor, diphacinone, dicumarol, chlorophacinone, bromadiolone, difenacoum, flocoumafen, and brodifacoum) in human blood by liquid chromatography-tandem mass spectrometry. After liquid-liquid extraction, the anticoagulant rodenticides were separated on an Eclipse Plus C18 column. Linearities were observed for each analyte in blood ranging from 0.5 to 50 ng/mL, with correlation coefficients over 0.99. The limits of detection ranged from 0.01 to 0.2 ng/mL, and the limits of quantification were 0.5 ng/mL for all analytes. The intraday and interday precisions were <15%, and accuracies ranged from 80.3% to 111.0%. This validated method with high sensitivity has been applied in three anticoagulant rodenticide poisoning cases and has been used successfully in monitoring blood concentrations for months. © 2017 American Academy of Forensic Sciences.

  2. In situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction for the determination of neurotransmitters in Parkinson's rat brain microdialysates by ultra high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    He, Yongrui; Zhao, Xian-En; Zhu, Shuyun; Wei, Na; Sun, Jing; Zhou, Yubi; Liu, Shu; Liu, Zhiqiang; Chen, Guang; Suo, Yourui; You, Jinmao

    2016-08-05

    Simultaneous monitoring of several neurotransmitters (NTs) linked to Parkinson's disease (PD) has important scientific significance for PD related pathology, pharmacology and drug screening. A new simple, fast and sensitive analytical method, based on in situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) in a single step, has been proposed for the quantitative determination of catecholamines and their biosynthesis precursors and metabolites in rat brain microdialysates. The method involved the rapid injection of the mixture of low toxic bromobenzene (extractant) and acetonitrile (dispersant), which containing commercial Lissamine rhodamine B sulfonyl chloride (LRSC) as derivatization reagent, into the aqueous phase of sample and buffer, and the following in situ DUADLLME procedure. After centrifugation, 50μL of the sedimented phase (bromobenzene) was directly injected for ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection in multiple reaction monitoring (MRM) mode. This interesting combination brought the advantages of speediness, simpleness, low matrix effects and high sensitivity in an effective way. Parameters of in situ DUADLLME and UHPLC-MS/MS conditions were all optimized in detail. The optimum conditions of in situ DUADLLME were found to be 30μL of microdialysates, 150μL of acetonitrile containing LRSC, 50μL of bromobenzene and 800μL of NaHCO3-Na2CO3 buffer (pH 10.5) for 3.0min at 37°C. Under the optimized conditions, good linearity was observed with LODs (S/N>3) and LOQs (S/N>10) of LRSC derivatized-NTs in the range of 0.002-0.004 and 0.007-0.015 nmol/L, respectively. It also brought good precision (3.2-12.8%, peak area CVs%), accuracy (94.2-108.6%), recovery (94.5-105.5%) and stability (3.8-8.1%, peak area CVs%) results. Moreover, LRSC derivatization significantly improved chromatographic resolution and MS detection sensitivity of NTs when compared with the reported studies through the introduction of a permanent charged moiety from LRSC into NTs. Taken together, this in situ DUADLLME method was successfully applied for the simultaneous determination of six NTs in biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Determination of anthelmintic drug residues in milk using ultra high performance liquid chromatography-tandem mass spectrometry with rapid polarity switching.

    PubMed

    Whelan, Michelle; Kinsella, Brian; Furey, Ambrose; Moloney, Mary; Cantwell, Helen; Lehotay, Steven J; Danaher, Martin

    2010-07-02

    A new UHPLC-MS/MS (ultra high performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added concentration step to detect most of the analytes at <1 microg kg(-1) levels in milk. Anthelmintic residues were extracted into acetonitrile using magnesium sulphate and sodium chloride to induce liquid-liquid partitioning followed by dispersive solid phase extraction for cleanup. The extract was concentrated into dimethyl sulphoxide, which was used as a keeper to ensure analytes remain in solution. Using rapid polarity switching in electrospray ionisation, a single injection was capable of detecting both positively and negatively charged ions in a 13 min run time. The method was validated at two levels: the unapproved use level and at the maximum residue level (MRL) according to Commission Decision (CD) 2002/657/EC criteria. The decision limit (CCalpha) of the method was in the range of 0.14-1.9 and 11-123 microg kg(-1) for drugs validated at unapproved and MRL levels, respectively. The performance of the method was successfully verified for benzimidazoles and levamisole by participating in a proficiency study.

  4. An on-spot internal standard addition approach for accurately determining colistin A and colistin B in dried blood spots using ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Tsai, I-Lin; Kuo, Ching-Hua; Sun, Hsin-Yun; Chuang, Yu-Chung; Chepyala, Divyabharathi; Lin, Shu-Wen; Tsai, Yun-Jung

    2017-10-25

    Outbreaks of multidrug-resistant Gram-negative bacterial infections have been reported worldwide. Colistin, an antibiotic with known nephrotoxicity and neurotoxicity, is now being used to treat multidrug-resistant Gram-negative strains. In this study, we applied an on-spot internal standard addition approach coupled with an ultra high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify colistin A and B from dried blood spots (DBSs). Only 15μL of whole blood was required for each sample. An internal standard with the same yield of extraction recoveries as colistin was added to the spot before sample extraction for accurate quantification. Formic acid in water (0.15%) with an equal volume of acetonitrile (50:50v/v) was used as the extraction solution. With the optimized extraction process and LC-MS/MS conditions, colistin A and B could be quantified from a DBS with respective limits of quantification of 0.13 and 0.27μgmL -1 , and the retention times were < 2min. The relative standard deviations of within-run and between-run precisions for peak area ratios were all < 17.3%. Accuracies were 91.5-111.2% for lower limit of quantification, low, medium, and high QC samples. The stability of the easily hydrolyzed prodrug, colistin methanesulfonate, was investigated in DBSs. Less than 4% of the prodrug was found to be hydrolyzed in DBSs at room temperature after 48h. The developed method applied an on-spot internal standard addition approach which benefited the precision and accuracy. Results showed that DBS sampling coupled with the sensitive LC-MS/MS method has the potential to be an alternative approach for colistin quantification, where the bias of prodrug hydrolysis in liquid samples is decreased. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simultaneous determination of AM80 (tamibarotene) and WJD-A-1 in rat plasma by ultra high-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.

    PubMed

    Leng, Ping; Yang, Zhao; Ma, Baohua; Li, Jing; Sun, Jialin; Xie, Yiming; Sun, Yong

    2018-03-05

    A compound (WJD-A-1) was previously reported as a candidate prodrug of Am80 (tamibarotene), which was approved in Japan in 2005 as a therapeutic agent for recurrent refractory acute promyelocytic leukaemia. A rapid, selective and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the first time to simultaneously determine WJD-A-1 and its major phase-I metabolites AM80 in rat plasma. After a simple sample preparation procedure by protein precipitation with methanol and acetonitrile, WJD-A-1, AM80 and the internal standard were chromatographed on an ACQUITY UPLC TM BEH C 18 column. The mobile phase consisted of methanol-0.1% formic acid (80:20, v/v) and the flow rate was 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. Each plasma sample was chromatographed within 2.6 min. The linear calibration curves for WJD-A-1 and the AM80 were obtained in the concentration range of 5.40-5.40 × 10 3 and 5.08-5.08 × 10 3  ng/mL, respectively (r ≥ 0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 8% and the accuracy (relative error, RE) was within ±6.8%, determined from quality control (QC) samples for the analytes. The method herein described was fully validated and successfully applied to pharmacokinetic study of WJD-A-1 following an intravenous administration of 300 μg/kg WJD-A-1 to rats.

  6. Ultra-sensitive assay for paclitaxel in intracellular compartments of A549 cells using liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Tingting; Ma, Wenxiao; Sun, Yantong; Yang, Yan; Zhang, Weiping; Fawcett, J Paul; Du, Hongwei; Gu, Jingkai

    2013-01-01

    A high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of paclitaxel in intracellular compartments using docetaxel as internal standard (IS) has been developed and validated. A549 cancer cells (10(6)) were incubated with paclitaxel (2ng/mL) for up to 4h and then subjected to sequential extraction of cytosolic, membrane/organelle, nuclear and cytoskeleton soluble protein. Fractions were ultrasonicated to release protein bound paclitaxel after which drug was extracted using liquid-liquid extraction with diethyl ether:dichloromethane (2:1, v/v). Chromatographic separation was then carried out on an Ascentis Express C18 column (50mm×4.6mm, 2.7μm) with a mobile phase of acetonitrile:0.1% formic acid in water (50:50, v/v). Detection involved electrospray positive ionization followed by multiple reactions monitoring of the precursor-to-product ion transitions of paclitaxel at m/z 854.4→286.3 and docetaxel at m/z 808.6→226.1. Assay validation based on samples of total cell extract in the same buffer as protein fractions showed the assay was linear over the range 2-600pg/mL with intra- and inter-day precision (as relative standard deviation) and accuracy (as relative error) of <7% and <±12%, respectively. Recovery was approximately 70% and matrix effects were minimal. The distribution of paclitaxel in subcellular components of A549 cancer cells was mainly into the cytoskeletal compartment. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Determination of aflatoxins in medicinal plants by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Siddique, Nadeem A; Mujeeb, Mohd; Ahmad, Sayeed; Panda, Bibhu P; Makhmoor, Mohd

    2013-01-01

    The intention of the proposed work is to study the presence of the aflatoxins B1, B2, G1 and G2 in medicinal plants, namely Mucuna pruriens, Delphinium denudatum and Portulaca oleraceae. The aflatoxins were extracted, purified by immunoaffinity column chromatography and analysed by high-performance liquid chromatography-tandem quadrupole mass spectrometry with electrospray ionisation (HPLC-MS/MS). Fungal count was carried out in PDA media. A good linear relationship was found for AFB1, AFB2, AFG1 and AFG2 at 1-10 ppb (r>0.9995). The analyte accuracy under three different spiking levels was 86.7-108.1 %, with low per cent relative standard deviations in each case. The aflatoxins can be separated within 5 to7 min using an Agilent XDB C18-column. We found that AFB1 and AFB2 were in trace amounts below the detection limit in M. pruriens whilst they were not detected in D. denudatum. P. oleraceae was found to be contaminated with AFB1 and AFB2. AFG1 and AFG2 were not detected in M. pruriens, P. oleraceae and were below the detection limit in D. denudatum. This was consistent with very low numbers of fungal colonies observed after 6 hr of incubation. The analytical method developed is simple, precise, accurate, economical and can be effectively used to determine the aflatoxins in medicinal plants and therefore to control the quality of products. The aflatoxin levels in the plant extracts examined were related to the minimal fungal load in the medicinal plants examined.

  8. High throughput identification and quantification of 16 antipsychotics and 8 major metabolites in serum using ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Patteet, Lisbeth; Maudens, Kristof E; Sabbe, Bernard; Morrens, Manuel; De Doncker, Mireille; Neels, Hugo

    2014-02-15

    Therapeutic drug monitoring of antipsychotics is important for optimizing therapy, explaining adverse effects, non-response or poor compliance. We developed a UHPLC-MS/MS method for quantification of 16 commonly used and recently marketed antipsychotics and 8 metabolites in serum. After liquid-liquid extraction using methyl tert-butyl ether, analysis was performed on an Agilent Technologies 1290 Infinity LC system coupled with an Agilent Technologies 6460 Triple Quadrupole MS. Separation with a C18 column and gradient elution at 0.5 mL/min resulted in a 6-min run-time. Detection was performed in dynamic MRM, monitoring 3 ion transitions per compound. Isotope labeled internal standards were used for every compound, except for bromperidol and levosulpiride. Mean recovery was 86.8%. Matrix effects were -18.4 to +9.1%. Accuracy ranged between 91.3 and 107.0% at low, medium and high concentrations and between 76.2 and 113.9% at LLOQ. Within-run precision was <15% (CV), except for asenapine and hydroxy-iloperidone. Between-run precision was aberrant only for 7-hydroxy-N-desalkylquetiapine, asenapine and reduced haloperidol. No interferences were found. No problems of instability were observed, even for olanzapine. The method was successfully applied on patient samples. The liquid-liquid extraction and UHPLC-MS/MS technique allows robust target screening and quantification of 23 antipsychotics and metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Analysis of major antioxidants from extracts of Myrmecodia pendans by UV/visible spectrophotometer, liquid chromatography/tandem mass spectrometry, and high-performance liquid chromatography/UV techniques.

    PubMed

    Engida, Adam Mekonnen; Faika, Sitti; Nguyen-Thi, Bich Thuyen; Ju, Yi-Hsu

    2015-06-01

    In the present work, heat reflux extraction with ethanol/water (80:20; v/v) as the solvent was used to extract antioxidants from Myrmecodia pendans. The crude extract (CE) was fractionated using hexane and ethyl acetate. Ethyl acetate fraction (EAF) and aqueous fraction were collected. Antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power of the CE, EAF, and aqueous fraction were evaluated. EAF showed comparable antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power to those of the CE. UV/visible, liquid chromatography/electrospray ionization/tandem mass spectrometry, and high-performance liquid chromatography were employed for identifying the major antioxidant compounds in the EAF. Three major phenolic compounds (rosmarinic acid, procyanidin B1, and polymer of procyanidin B1) were identified. The first two compounds were confirmed and quantified by high-performance liquid chromatography using authentic standards, but confirmation of the third compound was hampered by a lack of commercial standard. Concentrations of rosmarinic acid and procyanidin B1 in the EAF were found to be 20.688 ± 1.573 mg/g dry sample and 3.236 ± 0.280 mg/g dry sample, respectively. All these three compounds are reported for the first time in sarang semut. Copyright © 2014. Published by Elsevier B.V.

  10. Simultaneous detection and quantitation of organic impurities in methamphetamine by ultra-high-performance liquid chromatography-tandem mass spectrometry, a complementary technique for methamphetamine profiling.

    PubMed

    Li, Li; Brown, Jaclyn L; Toske, Steven G

    2018-04-06

    The analysis of organic impurities plays an important role in the impurity profiling of methamphetamine, which in turn provides valuable information about methamphetamine manufacturing, in particular its synthetic route, chemicals, and precursors used. Ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) is ideally suited for this purpose due to its excellent sensitivity, selectivity, and wide linear range in multiple reaction monitoring (MRM) mode. In this study, a dilute-and-shoot UHPLC-MS/MS method was developed for the simultaneous identification and quantitation of 23 organic manufacturing impurities in illicit methamphetamine. The developed method was validated in terms of stability, limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, and precision. More than 100 illicitly prepared methamphetamine samples were analyzed. Due to its ability to detect ephedrine/pseudoephedrine and its high sensitivity for critical target markers (eg, chloro-pseudoephedrine, N-cyclohexylamphetamine, and compounds B and P), more impurities and precursor/pre-precursors were identified and quantified versus the current procedure by gas chromatography-mass spectrometry (GC-MS). Consequently, more samples could be classified by their synthetic routes. However, the UHPLC-MS/MS method has difficulty in detecting neutral and untargeted emerging manufacturing impurities and can therefore only serve as a complement to the current method. Despite this deficiency, the quantitative information acquired by the presented UHPLC-MS/MS methodology increased the sample discrimination power, thereby enhancing the capacity of methamphetamine profiling program (MPP) to conduct sample-sample comparisons. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  11. Using a single tablet daily to treat latent tuberculosis infection in Brazil: bioequivalence of two different isoniazid formulations (300 mg and 100 mg) demonstrated by a sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry method in a randomised, crossover study

    PubMed Central

    Daher, André; Pitta, Luciana; Santos, Tereza; Barreira, Draurio; Pinto, Douglas

    2015-01-01

    The recommended treatment for latent tuberculosis (TB) infection in adults is a daily dose of isoniazid (INH) 300 mg for six months. In Brazil, INH was formulated as 100 mg tablets. The treatment duration and the high pill burden compromised patient adherence to the treatment. The Brazilian National Programme for Tuberculosis requested a new 300 mg INH formulation. The aim of our study was to compare the bioavailability of the new INH 300 mg formulation and three 100 mg tablets of the reference formulation. We conducted a randomised, single dose, open label, two-phase crossover bioequivalence study in 28 healthy human volunteers. The 90% confidence interval for the INH maximum concentration of drug observed in plasma and area under the plasma concentration vs. time curve from time zero to the last measurable concentration “time t” was 89.61-115.92 and 94.82-119.44, respectively. The main limitation of our study was that neither adherence nor the safety profile of multiple doses was evaluated. To determine the level of INH in human plasma, we developed and validated a sensitive, simple and rapid high-performance liquid chromatography-tandem mass spectrometry method. Our results showed that the new formulation was bioequivalent to the 100 mg reference product. This finding supports the use of a single 300 mg tablet daily strategy to treat latent TB. This new formulation may increase patients’ adherence to the treatment and quality of life. PMID:26038960

  12. Dispersive solid-phase extraction followed by high-performance liquid chromatography/tandem mass spectrometry for the determination of ricinine in cooking oil.

    PubMed

    Cai, Meiqiang; Chen, Xiaohong; Wei, Xiaoqing; Pan, Shengdong; Zhao, Yonggang; Jin, Micong

    2014-09-01

    A rapid and accurate method by liquid chromatography/tandem mass spectrometry (LC-MS/MS) using positive electrospray was established for the determination of ricinine in cooking oils. The homogenized samples, spiked with (13)C6-labelled ricinine as an internal standard, were extracted using ethanol/water (20:80, v/v) and purified by dispersive solid-phase extraction (dSPE) using primary-secondary amine (PSA) and C18 as adsorbents. The extract was separated in a short C18 reversed-phase column using methanol/water (25:75, v/v) as the mobile phase and detected in multiple reaction monitoring (MRM) mode with the absolute matrix effect of 93.2-102.2%. The alkali-metal adduct ions were discussed and the mass/mass fragmentation pathway was explained. Ricinine showed good linearity in the range of 0.5-50.0 μg/kg with the limit of quantitation 0.5 μg/kg. The recoveries were between 86.0% and 98.3% with the intra- and inter-day RSDs of 2.6-7.0%, 5.5-10.8%, respectively. This method could be applied to the rapid quantification of ricinine in cooking oils. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  13. Determination of fluoroquinolones in cattle manure-based biogas residue by ultrasonic-enhanced microwave-assisted extraction followed by online solid phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lu, Xue-Feng; Zhou, Yang; Zhang, Jian; Ren, Yu-Peng

    2018-06-01

    The present work describes the development and application of an ultrasonic-enhanced microwave-assisted extraction (UEMAE) followed by online solid phase extraction (SPE)-ultra-high performance liquid chromatography-tandem mass spectrometry method for the analysis of 14 fluoroquinolones in cattle manure-based biogas residue (CMBBR). The UEMAE was performed using the mixed solution of sodium dihydrogen phosphate and disodium ethylenediamine tetraacetic acid, avoiding use of any organic solvent. The online SPE system employed two solid phase extraction columns in a parallel manner, and the extraction was performed by passing 1 mL of the extract through the column. Quantification was performed using standard spiked samples and structural analogue internal standard, which were indispensable to reduce the matrix effects. Validation parameters were performed and good linearity (R 2  > 0.99 in all cases) and precision (inter- and intra-day relative standard deviations were lower than 12.8%) were obtained. Limits of detection were as low as 0.021 ng ∙ g -1 and lower limits of quantification were 0.5 ng ∙ g -1 for all fluoroquinolones. The overall extraction recovery, which was the product of the UEMAE recovery and the online SPE recovery, was assessed for three concentration levels (0.8, 40 and 400 ng ∙ g -1 ) and acceptable values (74.3-99.3%) were found. As a part of the method validation, the developed method has been used to analyze real CMBBR samples. Nine fluoroquinolones were found in the concentration range of 0.9-74.6 ng ∙ g -1 , while five were not detected in the samples. The results showed the method could be adapted for screening the presence or the final fate of fluoroquinolones during fermentation of animal waste. Copyright © 2018. Published by Elsevier B.V.

  14. Negative-pressure cavitation extraction for the determination of flavonoids in pigeon pea leaves by liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Wei; Fu, Yujie; Zu, Yuangang; Kong, Yu; Zhang, Lin; Zu, Baishi; Efferth, Thomas

    2009-05-01

    A new method, namely negative-pressure cavitation extraction (NPCE), followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) is presented for the extraction and quantification of flavonoids in pigeon pea leaves. This method combines the high efficiency of NPCE and the sensitivity and accuracy of MS/MS. The influential parameters of the NPCE procedure including liquid/solid ratio, extraction time, nitrogen flow and number of extraction cycles were optimized. Under optimized conditions, the efficiency of NPCE for extracting five flavonoids was compared to microwave-assisted extraction (MAE), ultrasonic extraction (USE) and heating reflux extraction (HRE). Additionally, structural disruption to pigeon pea leaves samples with different extraction methods was investigated by scanning electron microscopy. The relative recovery with NPCE was equivalent to or higher than that with USE and obviously higher than those with MAE and HRE which are usually conducted in higher temperatures. Furthermore, because NPCE was performed with nitrogen at room temperature, the degradation and oxidation of analytes were avoided. In addition, the NPCE method was validated in terms of repeatability and reproducibility, relative standard deviation for relative recovery was lower than 5.84 and 8.83%, respectively. The method was also successfully applied for the quantification of five flavonoids in pigeon pea leaves. All these results suggest that the developed NPCE-LC-MS/MS method represents an excellent alternative for the extraction and quantification of flavonoids in other plant materials.

  15. Detailed phenolic composition of Vidal grape pomace by ultrahigh-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Luo, Lanxin; Cui, Yan; Zhang, Shuting; Li, Lingxi; Suo, Hao; Sun, Baoshan

    2017-11-15

    Vidal Blanc grape (Vitis vinifera cv.) is the predominant white grape variety used for the production of icewine in China's Liaoning province. In this paper, the development and validation of the method by ultrahigh-performance liquid chromatography-tandem mass spectrometry has been performed for determination of the detailed phenolic composition in the skin, seed and stem of Vidal grapes. The validation of the method was realized by calculating the linearity, repeatability, precision, stability and the limits of detection (LOD) and quantification (LOQ) of standard solutions. All the curves exhibited good linearity (r 2 >0.9997) and the LOD and LOQ were in the range of 0.002-0.025 and 0.006-0.086μg/ml, respectively. Good repeatability (RSD<4.3%) and stability (RSD<3.7%) were also found. Results confirmed that the developed method was more effective and sensitive for simultaneous determination of the major phenolic compounds in Vidal grape pomace. The optimized and validated method of ultrahigh-performance liquid chromatography tandem two complementary techniques, fourier transform ion cyclotron resonance mass spectrometry and triple-quadrupole mass spectrometry, allowed to identify and quantify up to 35 phenolic compounds in Vidal grape pomace, which has, as far as we know, been reported this grapevine variety for the first time. Seeds, skins and stems exhibited different qualitative and quantitative phenolic profiles. These results provided useful information for recovery of phenolic antioxidants from different parts of icewine pomace. Copyright © 2017. Published by Elsevier B.V.

  16. Development and validation of two liquid chromatography-tandem mass spectrometry methods for the determination of silibinin and silibinin hemisuccinate in human plasma.

    PubMed

    Sala, Federica; Albares, Pablo; Colovic, Milena; Persiani, Stefano; Rovati, Lucio C

    2014-01-15

    To investigate the pharmacokinetics of silibinin and silibinin hemisuccinate in human plasma, two high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were developed and validated. The methods require a small volume of sample (100μL), and the recovery of the analytes was complete with a good reproducibility (CV% 1.7-9.5), after a simple protein precipitation. Naringenin was used as internal standard. The chromatographic methods provided a good separation of diastereoisomers A and B of both silibinin and silibinin hemisuccinate onto a Chromolith Performance RP18e 100mm×3mm column, with a resolution of peaks from plasma matrix in less than 6min. The methods precision values expressed as CV% were always ≤6.2% and the accuracy was always well within the acceptable 15% range. Quantification was performed on a triple-quadrupole tandem mass spectrometer by Selected Reaction Monitoring (SRM) mode, in a negative ion mode, via electrospray ionization (ESI). The lower limit of quantitation was set at 5.0ng/mL (silibinin) and 25.0ng/mL (silibinin hemisuccinate), and the linearity was validated up to 1000.0 and 12,500.0ng/mL, for silibinin and silibinin hemisuccinate, respectively, with correlation coefficients (R(2)) of 0.991 or better. The methods were suitable for pharmacokinetic studies and were successfully applied to human plasma samples from subjects treated intravenously with Legalon(®) SIL at the dose of 20mg/kg, expressed as silibinin. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Targeted profiling of hydrophilic constituents of royal jelly by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Pina, Athanasia; Begou, Olga; Kanelis, Dimitris; Gika, Helen; Kalogiannis, Stavros; Tananaki, Chrysoula; Theodoridis, Georgios; Zotou, Anastasia

    2018-01-05

    In the present work a Hydrophilic Interaction Liquid Chromatography-tandem Mass Spectrometry (HILIC-MS/MS) method was developed for the efficient separation and quantification of a large number of small polar bioactive molecules in Royal Jelly. The method was validated and provided satisfactory detection sensitivity for 88 components. Quantification was proven to be precise for 64 components exhibiting good linearity, recoveries R% >90% for the majority of analytes and intra- and inter-day precision from 0.14 to 20% RSD. Analysis of 125 fresh royal jelly samples of Greek origin provided useful information on royal jelly's hydrophilic bioactive components revealing lysine, ribose, proline, melezitose and glutamic acid to be in high abundance. In addition the occurrence of 18 hydrophilic nutrients which have not been reported previously as royal jelly constituents is shown. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Phenolic metabolites in plasma and tissues of rats fed with a grape pomace extract as assessed by liquid chromatography-tandem mass spectrometry.

    PubMed

    Rodriguez Lanzi, Cecilia; Perdicaro, Diahann J; Antoniolli, Andrea; Piccoli, Patricia; Vazquez Prieto, Marcela A; Fontana, Ariel

    2018-05-31

    Grape pomace extract (GPE) is a rich and relatively low-cost source of phenolic compounds. However, little is known about the main GPE metabolites in mammals, which could help explain the observed health-promoting effects. This study investigated the presence of parent compounds from flavanol, flavonol and stilbene families and their metabolites in rat plasma and tissues after an acute intake of GPE in doses of 300 and 600 mg kg/body weight. The measurement of free compounds and their metabolites was performed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Results showed the presence of epicatechin, epicatechin methyl-glucuronide, epicatechin methyl-sulphate, catechin, catechin-glucuronide, quercetin methyl-glucuronide, resveratrol-3-glucuronide, resveratrol-4-glucuronide and resveratrol-3-sulphate in plasma, which was dose dependent. The most abundant measured compound in plasma was epicatechin-glucuronide. The presence of glucuronidated and methyl-glucuronidated forms of catechin were observed in the liver at both doses, while epicatechin-glucuronide and methyl-glucuronide were detected only upon intake of 600 mg GPE/kg body weight. At this dose epicatechin-glucuronide and methyl-glucuronide were also detected in muscle, and catechin methyl-glucuronide in adipose tissue. Results show the main GPE metabolites present in rat tissues after oral consumption, contributing to better understand the health benefits of GPE and its potential utilization as a functional ingredient. Copyright © 2018. Published by Elsevier Inc.

  19. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish

    PubMed Central

    Yang, Xianli; Zhou, Lei; Tan, Yanglan; Shi, Xizhi; Zhao, Zhiyong; Nie, Dongxia; Zhou, Changyan; Liu, Hong

    2017-01-01

    In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1–4) and the N-sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v/v) with 0.1% formic and purified by dispersive solid-phase extraction (dSPE) with C18 silica and acidic alumina. Qualitative and quantitative detection for the target toxins were conducted under the multiple reaction monitoring (MRM) mode by using the positive electrospray ionization (ESI) mode after chromatographic separation on a TSK-gel Amide-80 HILIC column with water and acetonitrile. Matrix-matched calibration was used to compensate for matrix effects. The established method was further validated by determining the linearity (R2 ≥ 0.9900), average recovery (81.52–116.50%), sensitivity (limits of detection (LODs): 0.33–5.52 μg·kg−1; limits of quantitation (LOQs): 1.32–11.29 μg·kg−1) and precision (relative standard deviation (RSD) ≤ 19.10%). The application of this proposed approach to thirty shellfish samples proved its desirable performance and sufficient capability for simultaneous determination of multiclass PSP toxins in sea foods. PMID:28661471

  20. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Sensitive quantification of coixol, a potent insulin secretagogue, in Scoparia dulcis extract using high-performance liquid chromatography combined with tandem mass spectrometry and UV detection.

    PubMed

    Ali, Arslan; Haq, Faraz Ul; Ul Arfeen, Qamar; Sharma, Khaga Raj; Adhikari, Achyut; Musharraf, Syed Ghulam

    2017-10-01

    Diabetes is a major global health problem which requires new studies for its prevention and control. Scoparia dulcis, a herbal product, is widely used for treatment of diabetes. Recent studies demonstrate coixol as a potent and nontoxic insulin secretagog from S. dulcis. This study focuses on developing two quantitative methods of coixol in S. dulcis methanol-based extracts. Quantification of coixol was performed using high-performance liquid chromatography-tandem mass spectrometry (method 1) and high-performance liquid chromatography-ultraviolet detection (method 2) with limits of detection of 0.26 and 11.6 pg/μL, respectively, and limits of quantification of 0.78 and 35.5 pg/μL, respectively. S. dulcis is rich in coixol content with values of 255.5 ± 2.1 mg/kg (method 1) and 220.4 ± 2.9 mg/kg (method 2). Excellent linearity with determination coefficients >0.999 was achieved for calibration curves from 10 to 7500 ng/mL (method 1) and from 175 to 7500 ng/mL (method 2). Good accuracy (bias < -8.6%) and precision (RSD < 8.5%) were obtained for both methods. Thus, they can be employed to analyze coixol in plant extracts and herbal formulations. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with the pressurized liquid extraction for the quantification and confirmation of sulfonamides in the foods of animal origin.

    PubMed

    Yu, Huan; Tao, Yanfei; Chen, Dongmei; Wang, Yulian; Huang, Lingli; Peng, Dapeng; Dai, Menghong; Liu, Zhenli; Wang, Xu; Yuan, Zonghui

    2011-09-01

    The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Determination of aflatoxins in edible oil from markets in Hebei Province of China by liquid chromatography-tandem mass spectrometry.

    PubMed

    Yang, Li-xin; Liu, Yin-ping; Miao, Hong; Dong, Bin; Yang, Na-jing; Chang, Feng-qi; Yang, Li-xue; Sun, Jing-bo

    2011-01-01

    Analysis of aflatoxin B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2) in 76 edible oil samples (peanut oil, soybean oil, corn embryo oil and blended oil) was performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The oils were sampled from three areas (Shijiazhuang, Baoding and Tangshan) of Hebei Province of China. AFB1 was detected in 22 samples representing 28.9%, followed by AFB2 (7.89%) and AFG1 (3.95%), while no AFG2 contamination was detected in any samples. AFB1 levels in oil samples ranged 0.14-2.72 µg kg(-1) and AFB2 ranged 0.15-0.36 µg kg(-1), while lower levels of 0.01-0.02 µg kg(-1) for AFG1 were recorded. The paper is part of an on-going investigation of aflatoxin contamination in Chinese edible oils.

  4. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.

    PubMed

    Kwak, Byung-Man; Jeong, In-Seek; Lee, Moon-Seok; Ahn, Jang-Hyuk; Park, Jong-Su

    2014-12-15

    A rapid and simple sample preparation method for vitamin D3 (cholecalciferol) was developed for emulsified dairy products such as milk-based infant formulas. A sample was mixed in a 50 mL centrifuge tube with the same amount of water and isopropyl alcohol to achieve chemical extraction. Ammonium sulfate was used to induce phase separation. No-heating saponification was performed in the sample tube by adding KOH, NaCl, and NH3. Vitamin D3 was then separated and quantified using liquid chromatography-tandem mass spectrometry. The results for added recovery tests were in the range 93.11-110.65%, with relative standard deviations between 2.66% and 2.93%. The results, compared to those obtained using a certified reference material (SRM 1849a), were within the range of the certificated values. This method could be implemented in many laboratories that require time and labour saving. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. The Analytical Chemistry of Drug Monitoring in Athletes

    NASA Astrophysics Data System (ADS)

    Bowers, Larry D.

    2009-07-01

    The detection and deterrence of the abuse of performance-enhancing drugs in sport are important to maintaining a level playing field among athletes and to decreasing the risk to athletes’ health. The World Anti-Doping Program consists of six documents, three of which play a role in analytical development: The World Anti-Doping Code, The List of Prohibited Substances and Methods, and The International Standard for Laboratories. Among the classes of prohibited substances, three have given rise to the most recent analytical developments in the field: anabolic agents; peptide and protein hormones; and methods to increase oxygen delivery to the tissues, including recombinant erythropoietin. Methods for anabolic agents, including designer steroids, have been enhanced through the use of liquid chromatography/tandem mass spectrometry and gas chromatography/combustion/isotope-ratio mass spectrometry. Protein and peptide identification and quantification have benefited from advances in liquid chromatography/tandem mass spectrometry. Incorporation of techniques such as flow cytometry and isoelectric focusing have supported the detection of blood doping.

  6. Simultaneous determination of ambroxol and salbutamol in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.

    PubMed

    Guo, Zhening; Chen, Yangsheng; Ding, Xiaoliang; Huang, Chenrong; Miao, Liyan

    2016-11-01

    A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry assay method was developed for simultaneous determination of ambroxol and salbutamol in human plasma using citalopram hydrobromide as internal standard (IS). The sample was alkalinized with ammonia water (33:67, v/v) and extracted by single liquid-liquid extraction with ethyl acetate. Separation was achieved on Waters Acquity UPLC BEH C 18 column using a gradient program at a flow rate of 0.2 mL/min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 378.9 → 263.6 (ambroxol), m/z 240.2 → 147.7 (salbutamol) and m/z 325.0 → 261.7 (IS). The total analytical run time was relatively short (3 min). Calibration curves were linear in the concentration range of 0.5-100.0 ng/mL for ambroxol and 0.2-20.0 ng/mL for salbutamol, with intra- and inter-run precision (relative standard deviation) <15% and accuracy (relative error) ranging from 97.7 to 112.1% for ambroxol and from 94.5 to 104.1% for salbutamol. The method was successfully applied in a clinical pharmacokinetic study of the compound ambroxol and salbutamol tablets. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Simultaneous determination of blonanserin and its metabolite in human plasma and urine by liquid chromatography-tandem mass spectrometry: application to a pharmacokinetic study.

    PubMed

    Wen, Yu-Guan; Ni, Xiao-Jia; Zhang, Ming; Liu, Xia; Shang, De-Wei

    2012-08-15

    Blonanserin is a novel atypical antipsychotic with highly selective receptor antagonist activity to dopamine D₂ and 5-HT(2A). N-desethyl blonanserin (blonanserin C) is its major active metabolite in human plasma. Herein we report a new highly sensitive, selective, and rapid liquid chromatography-tandem mass spectrometry method to determine blonanserin and blonanserin C simultaneously in human plasma and urine, with N-desethyl-chlor-blonanserin (blonanserin D) as internal standard (IS). Blonanserin and blonanserin C were extracted from aliquots of plasma and urine with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using an Agilent Eclipse Plus C₁₈ column. The mobile phase was composed of: acetonitrile and ammonium formate-formic acid buffer containing 5mM ammonium formate and 0.1% formic acid (87:13, v/v). To quantify blonanserin, blonanserin C, and blonanserin D, respectively, multiple reaction monitoring (MRM) transition of m/z 368.2→297.2, m/z 340.2→297.1, and m/z 356.2→313.3 was performed in positive mode. The analysis time was about 5.5 min. The calibration curve was linear in the concentration range of 0.01-2 ng/ml. The lower limit of quantification reached 0.01 ng/ml. The intra and inter-day precision and relative errors were less than 8.0% and 6.6% for three QC levels in plasma and urine. The current LC-MS/MS method was validated as simple, sensitive, and accurate and has been successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in humans. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Rapid analysis of aminoglycoside antibiotics in bovine tissues using disposable pipette extraction and ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Mastovska, Katerina; Lightfield, Alan R; Nuñez, Alberto; Dutko, Terry; Ng, Chilton; Bluhm, Louis

    2013-10-25

    A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pipette extraction, and analysis by a 3 min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The drug analytes include neomycin, streptomycin, dihydrosptreptomycin, and spectinomycin, which have residue tolerances in bovine in the US, and kanamicin, gentamicin, apramycin, amikacin, and hygromycin, which do not have US tolerances established in bovine tissues. Tobramycin was used as an internal standard. An additional drug, paromomycin also was validated in the method, but it was dropped during implementation due to conversion of neomycin into paromomycin. Proposed fragmentation patterns for the monitored ions of each analyte were elucidated with the aid of high resolution MS using a quadrupole-time-of-flight instrument. Recoveries from spiking experiments at regulatory levels of concern showed that all analytes averaged 70-120% recoveries in all tissues, except hygromycin averaged 61% recovery. Lowest calibrated levels were as low as 0.005 μg/g in matrix extracts, which approximately corresponded to the limit of detection for screening purposes. Drug identifications at levels <0.05 μg/g were made in spiked and/or real samples for all analytes and tissues tested. Analyses of 60 samples from 20 slaughtered cattle previously screened positive for aminoglycosides showed that this method worked well in practice. The UHPLC-MS/MS method has several advantages compared to the previous microbial inhibition screening assay, especially for distinguishing individual drugs from a mixture and improving identification of gentamicin in tissue samples. Published by Elsevier B.V.

  9. Development and validation of a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of β-lactam antibiotic concentration in human plasma.

    PubMed

    Rigo-Bonnin, Raül; Ribera, Alba; Arbiol-Roca, Ariadna; Cobo-Sacristán, Sara; Padullés, Ariadna; Murillo, Òscar; Shaw, Evelyn; Granada, Rosa; Pérez-Fernández, Xosé L; Tubau, Fe; Alía, Pedro

    2017-05-01

    The administration of β-lactam antibiotics in continuous infusion could let optimize the pharmacokinetic/pharmacodynamic parameters, especially in the treatment of serious bacterial infections. In this context, and also due to variability in their plasmatic concentrations, therapeutic drug monitoring (TDM) may be useful to optimize dosing and, therefore, be useful for the clinicians. We developed and validated a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of amoxicillin, ampicillin, cloxacillin, piperacillin, cefepime, ceftazidime, cefuroxime, aztreonam and meropenem concentrations in plasma. The chromatographic separation was achieved using an Acquity®-UPLC® BEH™ (2.1×100mm id, 1.7μm) reverse-phase C 18 column, with a water/acetonitrile linear gradient containing 0.1% formic acid at a 0.4mL/min flow rate. β-Lactam antibiotics and their internal standards were detected by electrospray ionization mass spectrometry in multiple reaction monitoring mode. Chromatography run time was 7.0min and β-lactam antibiotics eluted at retention times ranging between 1.08 and 1.91min. The lower limits of quantification were between 0.50 and 1.00mg/L. Coefficients of variation and relative bias absolute values were <13.3% and 14.7%, respectively. Recovery values ranged from 55.7% to 84.8%. Evaluation of the matrix effect showed ion enhancement for all antibiotics. No interferences or carry-over were observed. Our measurement procedure could be applied to daily clinical laboratory practice to measure the concentration of β-lactam antibiotics in plasma, for instance in patients with bone and joint infections and critically ill patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Simultaneous quantitation of hydrazine and acetylhydrazine in human plasma by high performance liquid chromatography-tandem mass spectrometry after derivatization with p-tolualdehyde.

    PubMed

    Song, Lu; Gao, Dan; Li, Shangfu; Wang, Yanwei; Liu, Hongxia; Jiang, Yuyang

    2017-09-15

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous quantitative analysis of hydrazine and acetylhydrazine in human plasma based on the strategy of p-tolualdehyde derivatization. The derivatization reactions were easily realized by ultrasonic manipulation for 40min. Good separation of the derivatization products was achieved using a C 18 column by gradient elution. The optimized mass transition ion-pairs (m/z) monitored for the two hydrazine derivatives were m/z 237.1≫>119.9 and m/z 176.9≫>117.8, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for hydrazine were 0.002 and 0.005ngmL -1 separately. And they were 0.03 and 0.05ngmL -1 for acetylhydrazine, respectively. The linear range was 0.005-50ngmL -1 for hydrazine and 0.05-500ngmL -1 for acetylhydrazine with R 2 greater than 0.999. The recovery range was determined to be 95.38-108.12% with the relative standard deviation (RSD) in the range of 1.24-14.89%. The method was successfully applied to detect 30 clinical plasma samples of pulmonary tuberculosis patients treated with isoniazid. The concentrations were from 0.04-1.99ngmL -1 for hydrazine and 0.06-142.43ngmL -1 for acetylhydrazine. The results indicated that our developed method had the potential for the detection of hydrazine toxicology in complex biological samples. Furthermore, the method has an important significance to clinical treatment with drugs. Copyright © 2017. Published by Elsevier B.V.

  11. Analysis of perfluorinated chemicals in umbilical cord blood by ultra-high performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Lien, Guang-Wen; Wen, Ting-Wen; Hsieh, Wu-Shiun; Wu, Kuen-Yuh; Chen, Chia-Yang; Chen, Pau-Chung

    2011-03-15

    Perfluorinated compounds (PFCs) can cross the placental barrier and enter fetal circulation. This study aimed at developing a fast and sensitive ultra-high performance liquid chromatography/tandem mass spectrometry method for the determination of twelve perfluorinated compounds in cord blood. Samples were processed with protein precipitation using formic acid and methanol, mixed with stable isotope labeled standard, followed by sonication and centrifugation, and were analyzed using a Waters ACQUITY UPLC coupled with a Waters Quattro Premier XE triple-quadrupole mass spectrometer. The instrument was operated in selected reaction monitoring (SRM) with negative electrospray ionization. Using BEH C(18) column (2.1 mm×50 mm, 1.7 μm) with 10-mM N-methylmorpholine/methanol gradient elution provided a fast chromatographic separation (5.5 min) and sharp peaks. Intra- and inter-day calibration bias was less than 7% and intra- and inter-day calibration of relative standard deviations were within 0.02-8.22% for all the analytes and concentrations. The recoveries of PFCs spiked into bovine serum ranged from 85 to 104% with relative standard deviations from 0.02 to 6.37%. The limits of quantitation (LOQs), defined as a signal-to-noise ratio of ten, ranged from 0.15 to 3.1 ng/mL for the twelve PFCs. Perfluorooctanoic acid (PFOA), perfluorooctyl sulfonate (PFOS), perfluoroundecanoic acid (PFUA) and perfluorononanoic acid (PFNA) were detected in up to 68% of umbilical cord plasma (n=444) in Taiwan Birth Panel Study and the health effect of these chemicals on children developmental deserves further investigation. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Determination of biocides in different environmental matrices by use of ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chen, Zhi-Feng; Ying, Guang-Guo; Lai, Hua-Jie; Chen, Feng; Su, Hao-Chang; Liu, You-Sheng; Peng, Fu-Qiang; Zhao, Jian-Liang

    2012-12-01

    A sensitive and robust method using solid-phase extraction and ultrasonic extraction for preconcentration followed by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS) has been developed for determination of 19 biocides: eight azole fungicides (climbazole, clotrimazole, ketoconazole, miconazole, fluconazole, itraconazole, thiabendazole, and carbendazim), two insect repellents (N,N-diethyl-3-methylbenzamide (DEET), and icaridin (also known as picaridin)), three isothiazolinone antifouling agents (1,2-benzisothiazolinone (BIT), 2-n-octyl-4-isothiazolinone (OIT), and 4,5-dichloro-2-n-octyl-isothiazolinone (DCOIT)), four paraben preservatives (methylparaben, ethylparaben, propylparaben, and butylparaben), and two disinfectants (triclosan and triclocarban) in surface water, wastewater, sediment, sludge, and soil. Recovery of the target compounds from surface water, influent, effluent, sediment, sludge, and soil was mostly in the range 70-120%, with corresponding method quantification limits ranging from 0.01 to 0.31 ng L(-1), 0.07 to 7.48 ng L(-1), 0.01 to 3.90 ng L(-1), 0.01 to 0.45 ng g(-1), 0.01 to 6.37 ng g(-1), and 0.01 to 0.73 ng g(-1), respectively. Carbendazim, climbazole, clotrimazole, methylparaben, miconazole, triclocarban, and triclosan were detected at low ng L(-1) (or ng g(-1)) levels in surface water, sediment, and sludge-amended soil. Fifteen target compounds were found in influent samples, at concentrations ranging between 0.4 (thiabendazole) and 372 ng L(-1) (methylparaben). Fifteen target compounds were found in effluent samples, at concentrations ranging between 0.4 (thiabendazole) and 114 ng L(-1) (carbendazim). Ten target compounds were found in dewatered sludge samples, at concentrations ranging between 1.1 (DEET) and 887 ng g(-1) (triclocarban).

  13. Non-allowed Pharmacologically Active Substances in Physical and Sexual Performance Enhancing Products

    PubMed Central

    Pellegrini, Manuela; Rotolo, Maria Concetta; Busardò, Francesco Paolo; Pacifici, Roberta; Pichini, Simona

    2017-01-01

    Background: Recently, a large amount of physical and sexual performance enhancing products have started to be freely sold mainly on internet web sites as dietary supplements. However, there a high suspicion that pharmacologically active substance, prohibited in these products, can be present to provide the expected effect. Methods: A simple and rapid systematic toxicological analysis by gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry has been applied after a liquid-liquid extraction at acidic, neutral and alkaline pH with chloroform-isopropanol (9:1 v/v). The assays were validated in the range from 10 mg to 250 mg/g products showing a good linearity for the calibration curves (r2 ≥0.99). Mean extraction recoveries of analytes from different products were always higher than 90% and intra-assay and inter-assay precision and accuracy were always better than 15%. Results: The developed method was applied to the analysis of products with a high percentage of sales in websites and smart and sexy shops. In twelve of eighty supplements, anabolic steroids, anti-estrogenic drugs, psychoactive substances and sildenafil and analogs were identified and quantified. Conclusion: Eventual health hazards caused by the hidden presence of pharmacologically active substances in physical and sexual performance enhancing products are reported. PMID:27799033

  14. High-Throughput Analysis of Sucrose Fatty Acid Esters by Supercritical Fluid Chromatography/Tandem Mass Spectrometry

    PubMed Central

    Hori, Katsuhito; Tsumura, Kazunobu; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-01-01

    Supercritical fluid chromatography (SFC) coupled with triple quadrupole mass spectrometry was applied to the profiling of sucrose fatty acid esters (SEs). The SFC conditions (column and modifier gradient) were optimized for the effective separation of SEs. In the column test, a silica gel reversed-phase column was selected. Then, the method was used for the detailed characterization of commercial SEs and the successful analysis of SEs containing different fatty acids. The present method allowed for fast and high-resolution separation of monoesters to tetra-esters within a shorter time (15 min) as compared to the conventional high-performance liquid chromatography. The applicability of our method for the analysis of SEs was thus demonstrated. PMID:26819875

  15. Quantitative analysis of multiple fatty acid ethanolamides using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lin, Lin; Yang, Haifeng; Jones, Peter J H

    2012-12-01

    Fatty acid ethanolamides (FAE) represent a group of lipid signaling molecules associated with many physiological and pharmacological actions; however, low FAE tissue levels pose challenges in terms of analytical characterization. The objective was to develop a competent ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for analysis of multiple FAE in animal and human tissue samples. Analytes were extracted using lipid-phase and solid-phase extraction procedures. Chromatographic separation was achieved using a gradient elution in 8 min. FAE were quantified by MS/MS in positive electrospray ionization mode. Linearity was shown in lower and higher FAE concentration ranges, with a limit of quantification (LOQ) ≤0.2 ng/ml for FAE including alpha-linolenoylethanolamide (ALEA), arachidonoylethanolamide (AEA), docosahexaenoylethanolamide (DHEA), linoleoylethanolamide (LEA), oleoylethanolamide (OEA) and palmitoylethanolamide (PEA). Accuracy was shown to be between 92.4% and 108.8%, and precision was <10% for all FAE species. In sum, this sensitive and reproducible method can be used to simultaneously determine multiple FAE at low concentrations in order to facilitate further study of the role of FAE on physiological state. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Study on pharmacokinetics of 3,4-divanillyltetrahydrofuran in rats by ultra-fast liquid chromatography/tandem mass spectrometry.

    PubMed

    Shan, Chen-Xiao; Cui, Xiao-Bing; Yu, Sheng; Chai, Chuan; Wen, Hong-Mei; Wang, Xin-Zhi; Sun, Xue

    2016-01-01

    3,4-Divanillyltetrahydrofuran is the main active ingredient of nettle root which can increase steroid hormones in the bloodstream for many of bodybuilders. To better understand its pharmacological activities, we need to determine its pharmacokinetic profiles. In this study, a rapid and sensitive ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed for the determination of 3,4-divanillyltetrahydrofuran in the plasma of rats. Chromatographic separation was performed on a C18 column at 40°C, with a gradient elution consisting of methanol and water containing 0.3% (v/v) formic acid at a flow rate of 0.8mL/min. The detection was performed using an electrospray triple-quadrupole MS/MS via positive ion multiple reaction monitoring mode. The lower limits-of-quantification determined were 0.5ng/mL. The intra- and inter-day precision (RSD%) was found to be within 15% and the accuracy (RE%) ranged from -4.0% to 7.0%. This simple yet sensitive method was fully validated and could be successfully applied to the study on pharmacokinetics of 3, 4-divanillyltetrahydrofuran. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Determination of 21 antibiotics in sea cucumber using accelerated solvent extraction with in-cell clean-up coupled to ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhu, Minghua; Zhao, Hongxia; Xia, Deming; Du, Juan; Xie, Huaijun; Chen, Jingwen

    2018-08-30

    An accelerated solvent extraction (ASE) with in-cell clean-up method coupled to ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to determine 21 antibiotics in sea cucumber. The analytes include 10 sulfonamides, 4 fluoroquinolones, 3 amphenicols, 2 beta-lactams, 1 lincosamide and trimethoprim. Optimal parameters of ASE method were obtained at 80 °C, 1 static cycle of 5 min with methanol/acetonitrile (1/1, v/v) using 2 g of C18 as adsorbent. Recoveries at 50.1-129.2% were achieved with RSD under 20%. Method detection limits ranged from 0.03 to 2.9 μg kg -1 . Compared to the reported ultrasound-assisted extraction method, the proposed method offered comparable extraction efficiency for sulfonamides from sea cucumber, but higher for other categories of antibiotics. This validated method was then successfully applied to sea cucumber samples and 9 antibiotics were detected with the highest concentration up to 57.7 μg kg -1 for norfloxacin. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. A new carbon-based magnetic material for the dispersive solid-phase extraction of UV filters from water samples before liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Piovesana, Susy; Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2017-07-01

    Magnetic solid-phase extraction is one of the most promising new extraction methods for liquid samples before ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. Several types of materials, including carbonaceous ones, have been prepared for this purpose. In this paper, for the first time, the preparation, characterization, and sorption capability of Fe 3 O 4 -graphitized carbon black (mGCB) composite toward some compounds of environmental interest were investigated. The synthesized mGCB consisted of micrometric GCB particles with 55 m 2  g -1 surface area bearing some carbonyl and hydroxyl functionalities and the surface partially decorated by Fe 3 O 4 microparticles. The prepared mGCB was firstly tested as an adsorbent for the extraction from surface water of 50 pollutants, including estrogens, perfluoroalkyl compounds, UV filters, and quinolones. The material showed good affinity to many of the tested compounds, except carboxylates and glucoronates; however, some compounds were difficult to desorb. Ten UV filters belonging to the chemical classes of benzophenones and p-aminobenzoates were selected, and parameters were optimized for the extraction of these compounds from surface water before UHPLC-MS/MS determination. Then, the method was validated in terms of linearity, trueness, intra-laboratory precision, and detection and quantification limits. In summary, the method performance (trueness, expressed as analytical recovery, 85-114%; RSD 5-15%) appears suitable for the determination of the selected compounds at the level of 10-100 ng L -1 , with detection limits in the range of 1-5 ng L -1 . Finally, the new method was compared with a published one, based on conventional solid-phase extraction with GCB, showing similar performance in real sample analysis. Graphical Abstract Workflow of the analytical method based on magnetic solid-phase extraction followed by LC-MS/MS determination.

  19. Determination of ten monohydroxylated polycyclic aromatic hydrocarbons by liquid-liquid extraction and liquid chromatography/tandem mass spectrometry.

    PubMed

    Fan, Ruifang; Ramage, Robert; Wang, Dongli; Zhou, Junqiang; She, Jianwen

    2012-05-15

    The aim of this study is to develop and validate an analytical method for the quantitation of ten urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) through high pressure liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). After enzymatic deconjugation, urine samples were extracted by liquid-liquid extraction (LLE) and OH-PAHs were analyzed by HPLC/MS/MS operated in negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) mode. LLE was conducted with the solvent mixture of pentane and toluene, which reduced the matrix interferences and enhanced the method sensitivity significantly. Deuterated and (13)C-labeled analogs are used as internal standards. Calibration curves of all target analytes shows favorable linearity within the concentration range of 5.9-15,000.0 ng/L for different OH-PAHs with the regression coefficients above 0.993. The limits of detection (LODs) in pooled urine ranged from 1.72 to 17.47 ng/L, which were much lower than those obtained by a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. The method shows satisfactory accuracy and precision when analyzing three different levels of OH-PAHs spiked in pooled urine. Except for 1-hydroxynaphthalene, recoveries of other OH-PAHs were in the range of 100 ± 20% with a variation coefficient of less than 13%. The measurement of OH-PAHs from a QC sample of the Centers for Disease Control and Prevention (CDC) generated results close to the values measured by CDC. This method has been successfully employed in the California Biomonitoring Program. Published by Elsevier B.V.

  20. Development of a liquid chromatography-tandem mass spectrometry method for quantitative analysis of trace d-amino acids.

    PubMed

    Nakano, Yosuke; Konya, Yutaka; Taniguchi, Moyu; Fukusaki, Eiichiro

    2017-01-01

    d-Amino acids have recently attracted much attention in various research fields including medical, clinical and food industry due to their important biological functions that differ from l-amino acid. Most chiral amino acid separation techniques require complicated derivatization procedures in order to achieve the desirable chromatographic behavior and detectability. Thus, the aim of this research is to develop a highly sensitive analytical method for the enantioseparation of chiral amino acids without any derivatization process using liquid chromatography-tandem mass spectrometry (LC-MS/MS). By optimizing MS/MS parameters, we established a quantification method that allowed the simultaneous analysis of 18 d-amino acids with high sensitivity and reproducibility. Additionally, we applied the method to food sample (vinegar) for the validation, and successfully quantified trace levels of d-amino acids in samples. These results demonstrated the applicability and feasibility of the LC-MS/MS method as a novel, effective tool for d-amino acid measurement in various biological samples. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  1. Comparison of two cell lysis procedures for recovery of microcystins in water samples from silver lake in Dover, Delaware, with microcystin producing cyanobacterial accumulations

    USGS Publications Warehouse

    Loftin, Keith A.; Meyer, Michael T.; Rubio, Fernando; Kamp, Lisa; Humphries, Edythe; Whereat, Ed

    2008-01-01

    A collaboration was developed between Abraxis, LLC, the State of Delaware Department of Natural Resources and Environmental Control Division of Water Resources Environmental Laboratory, the University of Delaware, and the United States Geological Survey to investigate the efficacy of the QuikLyse procedure developed by Abraxis, LLC as an alternative cell-lysis technique suitable for use with an existing liquid chromatography/tandem mass spectrometry research method developed at the United States Geological Survey Organic Geochemistry Research Laboratory to analyze cyanotoxins. A comparison of three sequential freeze/thaw cycles versus QuikLyse, a proprietary chemical lysis procedure was conducted on four water samples collected from Silver Lake in Dover, Delaware. Results from the Abraxis Microcystins-DM enzyme-linked immunosorbent assay and liquid chromatography/tandem mass spectrometry were tabulated as a function of the cell lysis technique. Stastical comparison of percent relative standard deviations showed no significant difference (alpha = 0.05) between both cell-lysis techniques when measured by enzyme-linked immunosorbent assay or liquid chromatography/tandem mass spectrometry for three of the four samples.

  2. Rapid steroid hormone quantification for congenital adrenal hyperplasia (CAH) in dried blood spots using UPLC liquid chromatography-tandem mass spectrometry.

    PubMed

    Janzen, Nils; Sander, Stefanie; Terhardt, Michael; Steuerwald, Ulrike; Peter, Michael; Das, Anibh M; Sander, Johannes

    2011-12-11

    Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500)nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Oral Fluid as a Biological Material for Antemortem Detection of Oxytetracycline in Pigs by Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Gajda, Anna; Jablonski, Artur; Bladek, Tomasz; Posyniak, Andrzej

    2017-01-18

    The presence of antibiotic residues in pig tissues requires a search for new methods for their antemortem detection. To find an alternative for postmortem pig carcass analysis, an oral fluid was tested. To prove the suitability of oral fluid for the detection of antibiotics administered by injection, oxytetracycline was chosen. Research was conducted on two groups of animals: group 1, 100% treated; and group 2, 50% treated and 50% untreated. Oxytetracycline was assayed by a high-performance liquid chromatography-tandem mass spectrometry method. The antibiotic was detectable 2 h post administration in group 1 and group 2 at the concentrations of 10653 ± 1421 μg/kg and 7457 ± 1145 μg/kg, respectively. At withdrawal period (21st day), oxytetracycline concentrations in oral fluid (30.8 ± 9.4 μg/kg in group 1 and 11.6 ± 5.6 μg/kg in group 2) were similar to those determined in muscle (34.5 ± 8.2 μg/kg). The concentrations of oxytetracycline in liver and kidney were 76.8 ± 22 μg/kg and 204 ± 49 μg/kg, respectively. The results of this study indicate that oral fluid analysis can be used for antemortem oxytetracycline detection in pigs, even if the half of animals in one pen are treated.

  4. [Liquid chromatography-tandem mass spectrometry method for determination of 10 macrolide antibiotics in pork samples using on-line solid phase extraction purification].

    PubMed

    Zhang, Xiaoguang; Liu, Dong; Liu, Hongran; Li, Qiang; Li, Lili; Wang, Lixia; Zhang, Yan

    2017-10-08

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method based on-line solid phase extraction (SPE) purification was established to determine 10 macrolide antibiotics in pork samples. The samples were extracted with acetonitrile, and the extracts were dried with rotary evaporator at 40℃, then the analytes were dissolved with 2 mL phosphate buffer. The solutions were purified and concentrated by on-line SPE with HLB cartridges. The analytes were eluted with methanol, and then transferred to XBridge BEH C18 column, separated with the mobile phases of 10 mmol/L ammonium acetate aqueous solution and acetonitrile. Finally, the target analytes were detected by tandem mass spectrometry. The results showed that good linearity was obtained in the range of 0.1-200 μg/L for the 10 macrolide antibiotics with correlation coefficients better than 0.990. The limits of detection were in range of 0.05-0.30 μg/kg and the limits of quantitation were in range of 0.10-1.00 μg/kg. The recoveries of the method were in range of 69.6%-115.2% at the spiked levels of 0.10-10.0 μg/kg for all analytes, with the relative standard deviations less than 10%. The developed method can be used for the determination of the 10 macrolide antibiotics in pork samples.

  5. Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of tigecycline in rat brain tissues.

    PubMed

    Munyeza, Chiedza F; Shobo, Adeola; Baijnath, Sooraj; Bratkowska, Dominika; Naiker, Suhashni; Bester, Linda A; Singh, Sanil D; Maguire, Glenn E M; Kruger, Hendrik G; Naicker, Tricia; Govender, Thavendran

    2016-06-01

    Tigecycline (TIG), a derivative of minocycline, is the first in the novel class of glycylcyclines and is currently indicated for the treatment of complicated skin structure and intra-abdominal infections. A selective, accurate and reversed-phase high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of TIG in rat brain tissues. Sample preparation was based on protein precipitation and solid phase extraction using Supel-Select HLB (30 mg/1 mL) cartridges. The samples were separated on a YMC Triart C18 column (150 mm x 3.0 mm. 3.0 µm) using gradient elution. Positive electrospray ionization (ESI+) was used for the detection mechanism with the multiple reaction monitoring (MRM) mode. The method was validated over the concentration range of 150-1200 ng/mL for rat brain tissue. The precision and accuracy for all brain analyses were within the acceptable limit. The mean extraction recovery in rat brain was 83.6%. This validated method was successfully applied to a pharmacokinetic study in female Sprague Dawley rats, which were given a dose of 25 mg/kg TIG intraperitoneally at various time-points. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Determination of organic acids in tissues and exudates of maize, lupin, and chickpea by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Erro, Javier; Zamarreño, Angel M; Yvin, Jean-Claude; Garcia-Mina, Jose M

    2009-05-27

    This article describes a fast and simple methodology for the extraction and determination of organic acids in tissues and root exudates of maize, lupin, and chickpea by LC/MS/MS. Its main advantage is that it does not require sample prepurification before HPLC analysis or sample derivatization to improve sensibility. The results obtained showed good precision and accuracy, a recovery close to 100%, and no significant matrix effect. Moreover, the sensibility of the method is in general better than that of previously described methodologies, with detection limits between 15 and 900 pg injected.

  7. Rapid and sensitive liquid chromatography-tandem mass spectrometric method for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural) in traditional Chinese medicine injections.

    PubMed

    Zang, Qingce; Gao, Yang; Huang, Luojiao; He, Jiuming; Lin, Sheng; Jin, Hongtao; Zhang, Ruiping; Abliz, Zeper

    2018-03-01

    With the rapid development and wide application of traditional Chinese medicine injection (TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. Establishing effective and practical analytical methods for safety evaluation and quality control of TCMI can help to improve the safety of TCMIs in clinical applications. In this study, a sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural, OMBF) in TCMI samples. Chromatographic separation was performed on a C18 reversed-phase column (150 mm × 2.1 mm, 5 µm) by gradient elution, using methanol-water containing 0.1% formic acid as mobile phase at the flow rate of 0.3 mL/min. MS/MS detection was performed on a triple quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction-monitoring mode. The method was sensitive with a limit of quantification of 0.3 ng/mL and linear over the range of 0.3-30 ng/mL ( r =0.9998). Intra- and inter-day precision for analyte was <9.52% RSD with recoveries in the range 88.0-109.67% at three concentration levels. The validated method was successfully applied to quantitatively determine the compound OMBF in TCMIs and glucose injections. Our study indicates that this method is simple, sensitive, practicable and reliable, and could be applied for safety evaluation and quality control of TCMIs and glucose injections.

  8. Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods.

    PubMed

    Illamola, S M; Labat, L; Benaboud, S; Tubiana, R; Warszawski, J; Tréluyer, J M; Hirt, D

    2014-08-15

    Lopinavir is an HIV protease inhibitor with high protein binding (98-99%) in human plasma. This study was designed to develop an ultrafiltration method to measure the unbound concentrations of lopinavir overcoming the non-specific binding issue. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of total concentrations of lopinavir in plasma was developed and validated, and an adaptation was also optimized and validated for the determination of unbound concentrations. The chromatographic separation was performed with a C18 column (100 mm × 2.1mm i.d., 5 μm particle size) using a mobile phase containing deionized water with formic acid, and acetonitrile, with gradient elution at a flow-rate of 350 μL min(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionization in positive ion mode. The method was validated over a clinical range of 0.01-1 μg/mL for human plasma ultrafiltrate and 0.1-15 μg/mL in human plasma. The inter and intra-assay accuracies and precisions were between 0.23% and 11.37% for total lopinavir concentrations, and between 3.50% and 13.30% for plasma ultrafiltrate (unbound concentration). The ultrafiltration method described allows an accurate separation of the unbound fraction of lopinavir, circumscribing the loss of drug by nonspecific binding (NSB), and the validated LC-MS/MS methodology proposed is suitable for the determination of total and unbound concentrations of lopinavir in clinical practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Determination of colistin in animal tissues, egg, milk, and feed by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Fu, Qin; Li, Xiaowei; Zheng, Kangni; Ke, Yuebin; Wang, Yingyu; Wang, Lina; Yu, Fugen; Xia, Xi

    2018-05-15

    A confirmatory method for the determination of colistin in animal tissues, egg, milk, and feed was developed and validated. Colistin A and colistin B were extracted from samples with the mixture of 10% trichloroacetic acid-acetonitrile and isolated with mixed-mode weak cation exchange cartridge. Analytes were separated from matrix components using ultra-high performance liquid chromatography, and detected with electrospray ionization on a triple quadrupole mass spectrometer. Mean recoveries ranged from 78.0% to 115.6% with intra-day and inter-day relative standard deviation lower than 8.4% and 12.4%, respectively. The quantitation limits for different matrices were between 5 and 30 μg/kg, which was satisfactory for surveillance monitoring. The developed method was applied to the analysis of real samples collected from different provinces of China, and 19 out of 348 samples were found to be contaminated, with the highest concentration of approximately 12,000 μg/kg colistin A and 10,000 μg/kg colistin B in feed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Method development for quantification of quizartinib in rat plasma by liquid chromatography/tandem mass spectrometry for pharmacokinetic application.

    PubMed

    Ezzeldin, Essam; Iqbal, Muzaffar; Mostafa, Gamal; Al-Rashood, Khalid A; El-Nahhas, Toqa

    2018-03-01

    Quizartinib is a highly potent inhibitor of the fms-like tyrosine kinase receptor, which is one of the most commonly mutated genes in acute myeloid leukemia. Quizartinib has shown a significant antileukemic clinical influence among relapsed/refractory acute myeloid leukemia patients. This study aimed at developing and validating an analytical method for the measurement of quizartinib in rat plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated according to US Food and Drug Administration guidelines, and the results obtained in this work met the set criteria. Liquid-liquid extraction was used and chromatographic separation was achieved on a BEHTM C 18 column. Detection of quizartinib was achieved in multiple reaction monitoring mode using positive-ion mode electrospray ionization. The MS/MS ion transitions at mass-to-charge ratios (m/z) of 561.129/114.09 and 441.16/84.03 were monitored for quizartinib and ibrutinib, respectively. The linear detection range was 2-1000 ng/mL (r > 0.998), with intra- and inter-day assay precisions ≤13.07 and 13.17%, respectively. This rapid, simple and sensitive method was validated and successfully applied to the pharmacokinetic study of quizartinib in rat samples. Copyright © 2017 John Wiley & Sons, Ltd.

  11. A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry.

    PubMed

    Khayoon, Wejdan Shakir; Saad, Bahruddin; Salleh, Baharuddin; Ismail, Nor Azliza; Abdul Manaf, Normaliza Hj; Abdul Latiff, Aishah

    2010-10-29

    The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B(1) and fumonisin B(2) by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C(18) solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith(®) RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min(-1). The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C(18) particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01-0.04 μg g(-1) fumonisin B(1) and fumonisin B(2), respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g(-1) fumonisins B(1) and B(2)), ranging from 84.0 to 106.0% for fumonisin B(1) and from 81.0 to 103.0% for fumonisin B(2). Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B(1) (range, 0.01-0.51 μg g(-1)) and fumonisin B(2) (0.05 μg g(-1)). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g(-1). Of the 14 inoculated samples, 57.1% contained fumonisin B(1) (0.16-41.0 μg g(-1)) and fumonisin B(2) (range, 0.22-50.0 μg g(-1)). Positive confirmation of selected samples was carried out using liquid chromatography-tandem mass spectrometry, using triple quadrupole analyzer and operated in the multiple reaction monitoring mode. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Liquid chromatography-tandem MS/MS method for simultaneous quantification of paracetamol, chlorzoxazone and aceclofenac in human plasma: An application to a clinical pharmacokinetic study.

    PubMed

    Mohamed, Dalia; Hegazy, Maha A; Elshahed, Mona S; Toubar, Safaa S; Helmy, Marwa I

    2018-07-01

    A facile, fast and specific method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous quantitation of paracetamol, chlorzoxazone and aceclofenac in human plasma was developed and validated. Sample preparation was achieved by liquid-liquid extraction. The analysis was performed on a reversed-phase C 18 HPLC column (5 μm, 4.6 × 50 mm) using acetonitrile-10 mM ammonium formate pH 3.0 (65:35, v/v) as the mobile phase where atrovastatin was used as an internal standard. A very small injection volume (3 μL) was applied and the run time was 2.0 min. The detection was carried out by electrospray positive and negative ionization mass spectrometry in the multiple-reaction monitoring mode. The developed method was capable of determining the analytes over the concentration ranges of 0.03-30.0, 0.015-15.00 and 0.15-15.00 μg/mL for paracetamol, chlorzoxazone and aceclofenac, respectively. Intraday and interday precisions (as coefficient of variation) were found to be ≤12.3% with an accuracy (as relative error) of ±5.0%. The method was successfully applied to a pharmacokinetic study of the three analytes after being orally administered to six healthy volunteers. Copyright © 2018 John Wiley & Sons, Ltd.

  13. An evaluation of sucrose as a possible contaminant in e-liquids for electronic cigarettes by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Kubica, Paweł; Wasik, Andrzej; Kot-Wasik, Agata; Namieśnik, Jacek

    2014-05-01

    The influence of sucrose combustion products on smoking and nicotine addiction is still controversial because the presence of the sucrose may be treated as a source of aldehydes and organic acids. In e-liquids used as refills for electronic cigarettes, which are made primarily of poly(propylene glycol), glycerine and ethanol, sucrose may be present at trace levels, and its impact on mainstream smoke formation, and hence on human health and smoking/nicotine addiction is unknown. An analytical method was developed where high-performance liquid chromatography in hydrophilic interaction liquid chromatography mode and tandem mass spectrometry were used for fast and simple determination of sucrose and other saccharides in e-liquids for electronic cigarettes. Minimal effort was required in the sample preparation step, and satisfactory results were obtained, and the sample matrix had an insignificant impact. The chromatographic separation was done using an Ascentis Express OH5 column (150 mm × 2.1 mm, 2.7 μm). The coefficients of variation for within-day precision for three concentrations were 2.4 %, 1.6 % and 2.3 %, and the between-day coefficients of variation for a single concentration were 2.1 %, 2.5 % and 1.7 % measured on the next 3 days. The detection limit was 0.73 μg/g, and the sucrose content in e-liquids ranged from 0.76 to 72.93 μg/g among 37 samples. Moreover, with the method presented it is possible to determine the presence of other saccharides such as fructose, glucose, maltose and lactose. However, only sucrose was found in all samples of e-liquids. The proposed method is rapid, simple and reliable in terms of high-performance liquid chromatography coupled with tandem mass spectrometry.

  14. Parallel artificial liquid membrane extraction as an efficient tool for removal of phospholipids from human plasma.

    PubMed

    Ask, Kristine Skoglund; Bardakci, Turgay; Parmer, Marthe Petrine; Halvorsen, Trine Grønhaug; Øiestad, Elisabeth Leere; Pedersen-Bjergaard, Stig; Gjelstad, Astrid

    2016-09-10

    Generic Parallel Artificial Liquid Membrane Extraction (PALME) methods for non-polar basic and non-polar acidic drugs from human plasma were investigated with respect to phospholipid removal. In both cases, extractions in 96-well format were performed from plasma (125μL), through 4μL organic solvent used as supported liquid membranes (SLMs), and into 50μL aqueous acceptor solutions. The acceptor solutions were subsequently analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using in-source fragmentation and monitoring the m/z 184→184 transition for investigation of phosphatidylcholines (PC), sphingomyelins (SM), and lysophosphatidylcholines (Lyso-PC). In both generic methods, no phospholipids were detected in the acceptor solutions. Thus, PALME appeared to be highly efficient for phospholipid removal. To further support this, qualitative (post-column infusion) and quantitative matrix effects were investigated with fluoxetine, fluvoxamine, and quetiapine as model analytes. No signs of matrix effects were observed. Finally, PALME was evaluated for the aforementioned drug substances, and data were in accordance with European Medicines Agency (EMA) guidelines. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmapsmore » of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.« less

  16. Simultaneous quantification of reparixin and paclitaxel in plasma and urine using ultra performance liquid chromatography-tandem mass spectroscopy (UHPLC-MS/MS): Application to a preclinical pharmacokinetic study in rats.

    PubMed

    Malhi, Sarandeep; Stesco, Nicholas; Alrushaid, Samaa; Lakowski, Ted M; Davies, Neal M; Gu, Xiaochen

    2017-03-01

    A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) assay was developed and validated to simultaneously quantify anticancer drugs reparixin and paclitaxel in this study. The compounds were extracted from plasma and urine samples by protein precipitation with acetone (supplemented with 0.1% formic acid). Chromatographic separation was achieved using a C18 column, and drug molecules were ionized using dual ion source electrospray and atmospheric pressure chemical ionization (DUIS: ESI-APCI). Reparixin and paclitaxel were quantified using negative and positive multiple reaction monitoring (MRM) mode, respectively. Stable isotope palcitaxel-D5 was used as the internal standard (IS). The assay was validated for specificity, recovery, carryover and sample stability under various storage conditions; it was also successfully applied to measure drug concentrations collected from a pharmacokinetic study in rats. The results confirmed that the assay was accurate and simple in quantifying both reparixin and paclitaxel in plasma and urine with minimal sample pretreatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Bisphenol A, 4-t-octylphenol, and 4-nonylphenol determination in serum by Hybrid Solid Phase Extraction-Precipitation Technology technique tailored to liquid chromatography-tandem mass spectrometry.

    PubMed

    Asimakopoulos, Alexandros G; Thomaidis, Nikolaos S

    2015-04-01

    A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and optimized for the simultaneous determination of bisphenol A, 4-t-octylphenol and 4-nonylphenol in human blood serum. For the first time, the electrospray ionization (ESI) parameters of probe position, voltage potential, sheath gas flow rate, auxiliary gas flow rate, and ion transfer tube temperature were thoroughly studied and optimized for each phenol by a univariate approach. As a consequence, low instrumental limits of detection were reported, demonstrating at 0.2 ng/mL (in solvent matrix) excellent injection repeatability (RSD<14.5%) and a confirmation peak for all target phenols. Extraction and purification of serum was performed by the novel Hybrid Solid Phase Extraction-Precipitation Technology technique (Hybrid SPE-PPT). The limits of detection in human blood serum were 0.80, 1.3 and 1.4 ng/mL for BPA, 4-t-OP and 4-NP, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Molecularly imprinted solid-phase extraction for the determination of ten macrolide drugs residues in animal muscles by liquid chromatography-tandem mass spectrometry.

    PubMed

    Song, Xuqin; Zhou, Tong; Liu, Qingying; Zhang, Meiyu; Meng, Chenying; Li, Jiufeng; He, Limin

    2016-10-01

    A simple and sensitive method based on molecularly imprinted solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry was developed for the determination of the residues of ten macrolide drugs in swine, cattle and chicken muscles samples. The molecularly imprinted polymers (MIPs) were synthesized using tylosin as a template and methacrylic acid as a functional monomer. Samples were extracted with sodium borate buffer solution and ethyl acetate, and purified by the MIP cartridge. The results showed that the cartridge exhibited good recognition performance for macrolides, and better purification effect than the traditional solid-phase extraction cartridges. Recoveries of analytes at three spiking levels 1, 5 and 20μgkg(-1) ranged from 60.7% to 100.3% with the relative standard deviations less than 14%. The limits of detection of the method were between 0.1 and 0.4μgkg(-1). The method is useful for the routine monitoring of the residues of macrolide drugs in animal muscles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Simultaneous determination of seven anticoagulant rodenticides in agricultural products by gel permeation chromatography and liquid chromatography-tandem mass spectrometry.

    PubMed

    Saito-Shida, Shizuka; Nemoto, Satoru; Matsuda, Rieko; Akiyama, Hiroshi

    2016-11-01

    A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid-liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC-MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC-MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005-0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.

  20. Identification of marker proteins for the adulteration of meat products with soybean proteins by multidimensional liquid chromatography-tandem mass spectrometry.

    PubMed

    Leitner, Alexander; Castro-Rubio, Florentina; Marina, Maria Luisa; Lindner, Wolfgang

    2006-09-01

    Soybean proteins are frequently added to processed meat products for economic reasons and to improve their functional properties. Monitoring of the addition of soybean protein to meat products is of high interest due to the existence of regulations forbidding or limiting the amount of soybean proteins that can be added during the processing of meat products. We have used chromatographic prefractionation on the protein level by perfusion liquid chromatography to isolate peaks of interest from extracts of soybean protein isolate (SPI) and of meat products containing SPI. After enzymatic digestion using trypsin, the collected fractions were analyzed by nanoflow liquid chromatography-tandem mass spectrometry. Several variants and subunits of the major seed proteins, glycinin and beta-conglycinin, were identified in SPI, along with two other proteins. In soybean-protein-containing meat samples, different glycinin A subunits could be identified from the peak discriminating between samples with and without soybean proteins added. Among those, glycinin G4 subunit A4 was consistently found in all samples. Consequently, this protein (subunit) can be used as a target for new analytical techniques in the course of identifying the addition of soybean protein to meat products.

  1. Development of a liquid chromatography–tandem mass spectrometry method for the determination of sulfonamides, trimethoprim and dapsone in honey and validation according to Commission Decision 2002/657/EC for banned compounds [corrected].

    PubMed

    Economou, Anastasios; Petraki, Olympia; Tsipi, Despina; Botitsi, Eleni

    2012-08-15

    This work reports a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for identification and quantification of seven sulfonamides, trimethoprim and dapsone in honey. The method is based on a solid-phase extraction (SPE) step of the target analytes with Oasis HLB cartridges after acidic hydrolysis of the honey sample to liberate the sugar-bound sulfonamides. Analysis was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive electro-spray ionization (ESI) mode with two different isotopically labeled internal standards with the view to improve the quantitative performance of the method. The method validation has been performed according to the Commission Decision 2002/657/EC; the average recoveries, measured at three concentration levels (1.5, 2.5 and 5.0 μg kg(-1)), have been estimated in the range 70 to 106% while the respective % relative standard deviations of the within-laboratory reproducibility ranged from 6 to 18%. Mean values of the expanded uncertainties calculated were in the range 22-41% at the 99% confidence level. Decision limit (CCα) and detection capability (CCβ) values were in the ranges 0.4-0.9 and 0.7-1.4 μg kg(-1), respectively. Matrix effects have been investigated demonstrating a moderate signal suppression/enhancement for most of the target compounds. The method described has been successfully applied to the analysis of honey samples; sulfamethoxazole, sulfathiazole and trimethoprim were detected in some cases. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Cannabinoids assessment in plasma and urine by high performance liquid chromatography-tandem mass spectrometry after molecularly imprinted polymer microsolid-phase extraction.

    PubMed

    Sánchez-González, Juan; Salgueiro-Fernández, Rocío; Cabarcos, Pamela; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2017-02-01

    A molecularly imprinted polymer (MIP) selective for cannabinoids [Δ 9 -tetrahydrocannabinol (Δ9-THC), 11-nor-9-carboxy-Δ 9 -tetrahydrocannabinol (Δ9-THC-COOH), and 11-hydroxy-Δ 9 -tetrahydrocannabinol (Δ9-THC-OH)] has been synthesized, fully characterized, and applied to the assessment of plasma and urine analysis of marijuana abuse by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Δ9-THC-COOH was used as a template molecule, whereas ethylene glycol dimethacrylate (EGDMA) was used as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The prepared MIP was found to be highly selective for cannabinoids typically found in blood and urine, and also for cannabinol (CBN) and cannabidiol (CBD). MIP beads (50 mg) were loaded inside a cone-shaped device made of a polypropylene (PP) membrane for microsolid-phase extraction (μ-SPE) in batch mode. Optimum retention of analytes (0.1 to 1.0 mL of plasma/urine) was achieved by fixing plasma/urine pH at 6.5 and assisting the procedure by mechanical shaking (150 rpm, 40 °C, 12 min). Optimum elution conditions implied 2 mL of a 90:10 methanol/acetic acid and ultrasound extraction (35 kHz, 325 W) for 6 min. Good precision was assessed by intra-day and inter-day assays. In addition, the method was found to be accurate after intra-day and inter-day analytical recovery assays and after analyzing control serum and urine control samples. The limits of quantification were in the range of 0.36-0.49 ng L -1 (plasma analysis) and 0.47-0.57 ng L -1 (urine analysis). These values are low enough for confirmative conclusions regarding marijuana abuse through blood and urine analysis. Graphical Abstract ᅟ.

  3. High rates of non-adherence to antihypertensive treatment revealed by high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis

    PubMed Central

    Tomaszewski, Maciej; White, Christobelle; Patel, Prashanth; Masca, Nicholas; Damani, Ravi; Hepworth, Joanne; Samani, Nilesh J; Gupta, Pankaj; Madira, Webster; Stanley, Adrian; Williams, Bryan

    2014-01-01

    Objectives Non-adherence to therapy is an important cause of suboptimal blood pressure control but few practical tools exist to accurately and routinely detect it. We used a simple urine-based assay to evaluate the prevalence of antihypertensive treatment non-adherence and its impact on blood pressure in a specialist hypertension centre. Methods 208 hypertensive patients (125 new referrals, 66 follow-up patients with inadequate blood pressure control and 17 renal denervation referrals) underwent assessment of antihypertensive drug intake using high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis at the time of clinical appointment. A total of 40 most commonly prescribed antihypertensive medications (or their metabolites) were screened for in spot urine samples. Results Overall, 25% of patients were totally or partially non-adherent to antihypertensive treatment (total non-adherence 10.1%, partial non-adherence 14.9%). The highest prevalence of partial and total non-adherence was among follow-up patients with inadequate blood pressure control (28.8%) and those referred for consideration of renal denervation (23.5%), respectively. There was a linear relationship between blood pressure and the numerical difference in detected/prescribed antihypertensive medications—every unit increase in this difference was associated with 3.0 (1.1) mm Hg, 3.1 (0.7) mm Hg and 1.9 (0.7) mm Hg increase in adjusted clinic systolic blood pressure, clinic diastolic blood pressure (DBP) and 24 h mean daytime DBP (p=0.0051, p=8.62×10−6, p=0.0057), respectively. Conclusions Non-adherence to blood pressure lowering therapy is common, particularly in patients with suboptimal blood pressure control and those referred for renal denervation. HP LC-MS/MS urine analysis could be used to exclude non-adherence and better stratify further investigations and intervention. PMID:24694797

  4. Concentration determination of urinary metabolites of N,N-dimethylacetamide by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Yamamoto, Shinobu; Matsumoto, Akiko; Yui, Yuko; Miyazaki, Shota; Kumagai, Shinji; Hori, Hajime; Ichiba, Masayoshi

    2018-03-27

    N,N-Dimethylacetamide (DMAC) is widely used in industry as a solvent. It can be absorbed through human skin. Therefore, it is necessary to determine exposure to DMAC via biological monitoring. However, the precision of traditional gas chromatography (GC) is low due to the thermal decomposition of metabolites in the high-temperature GC injection port. To overcome this problem, we have developed a new method for the simultaneous separation and quantification of urinary DMAC metabolites using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Urine samples were diluted 10-fold in formic acid, and 1-μl aliquots were injected into the LC-MS/MS equipment. A C18 reverse-phase Octa Decyl Silyl (ODS) column was used as the analytical column, and the mobile phase consisted of a mixture of methanol and aqueous formic acid solution. Urinary concentrations of DMAC and its known metabolites (N-hydroxymethyl-N-methylacetamide (DMAC-OH), N-methylacetamide (NMAC), and S- (acetamidomethyl) mercapturic acid (AMMA) ) were determined in a single run. The dynamic ranges of the calibration curves were 0.05-5 mg/l (r≥0.999) for all four compounds. The limits of detection for DMAC, DMAC-OH, NMAC, and AMMA in urine were 0.04, 0.02, 0.05, and 0.02 mg/l, respectively. Within-run accuracies were 96.5%-109.6% with relative standard deviations of precision being 3.43%-10.31%. The results demonstrated that the proposed method could successfully quantify low concentrations of DMAC and its metabolites with high precision. Hence, this method is useful for evaluating DMAC exposure. In addition, this method can be used to examine metabolite behaviors in human bodies after exposure and to select appropriate biomarkers.

  5. Concentration determination of urinary metabolites of N,N-dimethylacetamide by high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Yamamoto, Shinobu; Matsumoto, Akiko; Yui, Yuko; Miyazaki, Shota; Kumagai, Shinji; Hori, Hajime; Ichiba, Masayoshi

    2017-01-01

    Objectives: N,N-Dimethylacetamide (DMAC) is widely used in industry as a solvent. It can be absorbed through human skin. Therefore, it is necessary to determine exposure to DMAC via biological monitoring. However, the precision of traditional gas chromatography (GC) is low due to the thermal decomposition of metabolites in the high-temperature GC injection port. To overcome this problem, we have developed a new method for the simultaneous separation and quantification of urinary DMAC metabolites using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods: Urine samples were diluted 10-fold in formic acid, and 1-μl aliquots were injected into the LC-MS/MS equipment. A C18 reverse-phase Octa Decyl Silyl (ODS) column was used as the analytical column, and the mobile phase consisted of a mixture of methanol and aqueous formic acid solution. Results: Urinary concentrations of DMAC and its known metabolites (N-hydroxymethyl-N-methylacetamide (DMAC-OH), N-methylacetamide (NMAC), and S- (acetamidomethyl) mercapturic acid (AMMA) ) were determined in a single run. The dynamic ranges of the calibration curves were 0.05-5 mg/l (r≥0.999) for all four compounds. The limits of detection for DMAC, DMAC-OH, NMAC, and AMMA in urine were 0.04, 0.02, 0.05, and 0.02 mg/l, respectively. Within-run accuracies were 96.5%-109.6% with relative standard deviations of precision being 3.43%-10.31%. Conclusions: The results demonstrated that the proposed method could successfully quantify low concentrations of DMAC and its metabolites with high precision. Hence, this method is useful for evaluating DMAC exposure. In addition, this method can be used to examine metabolite behaviors in human bodies after exposure and to select appropriate biomarkers. PMID:29213009

  6. UHPLC-UV method for the determination of flavonoids in dietary supplements and for evaluation of their antioxidant activities.

    PubMed

    Magiera, Sylwia; Baranowska, Irena; Lautenszleger, Anna

    2015-01-01

    A simple and rapid ultra-high performance liquid chromatographic (UHPLC) method coupled with an ultraviolet detector (UV) has been developed and validated for the separation and determination of 14 major flavonoids ((±)-catechin, (-)-epicatechin, glycitin, (-)-epicatechin gallate, rutin, quercitrin, hesperidine, neohesperidine, daidzein, glycitein, quercetin, genistein, hesperetin, and biochanin A) in herbal dietary supplements. The flavonoids have been separated on a Chromolith Fast Gradient Monolithic RP-18e column utilizing a mobile phase composed of 0.05% trifluoroacetic acid in water and acetonitrile in gradient elution mode. Under these conditions, flavonoids were separated in a 5 min run. The selectivity of the developed UHPLC-UV method was confirmed by comparison with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The validation parameters such as linearity, sensitivity, precision, and accuracy were found to be highly satisfactory. The optimized method was applied to determination of flavonoids in different dietary supplements. Additionally, the developed HPLC-UV method combined with 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) assay was used in the evaluation of antioxidant activity of the selected flavonoids. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  8. Development of a polymeric ionic liquid coating for direct-immersion solid-phase microextraction using polyhedral oligomeric silsesquioxane as cross-linker.

    PubMed

    Chen, Chunyan; Liang, Xiaotong; Wang, Jianping; Zou, Ying; Hu, Huiping; Cai, Qingyun; Yao, Shouzhuo

    2014-06-27

    A novel solid-phase microextraction (SPME) fiber was developed by chemical binding of a crosslinked polymeric ionic liquid (PIL) on the surface of an anodized Ti wire, and was applied in direct-immersion mode for the extraction of perfluorinated compounds (PFCs) from water samples coupled with high performance liquid chromatography-tandem mass spectrometry analysis. The PIL coatings were synthesized by using 1-vinyl-3-hexylimidazolium hexafluorophosphate as monomer and methylacryloyl-substituted polyhedral oligomeric silsesquioxane (POSS) as cross-linker via free radical reaction. The proposed fiber coating exhibited high mechanical stability due to the chemical bonding between the coating and the Ti wire surface. The integration of POSS reagent enhanced the organic solvent resistance of the coating. The parameters affecting the extraction performance of the fiber coating including extraction time, pH of solution, ionic strength and desorption conditions were optimized. The developed PIL-POSS fiber showed good linearity (R<0.998) between 0.1 and 50ngmL(-1) with method detection limits ranging from 0.005 to 0.08ngmL(-1) depending on the analyte, and with relative standard deviation for single-fiber repeatability and fiber-to-fiber reproducibility less than 8.6% and 9.5%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A rapid method for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet by ultra performance liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan

    2013-05-01

    In present study, a rapid and sensitive method using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet. The optimum chromatographic separation was carried out on a reversed phase Waters® Acquity UPLC BEH C18 column (1.7 μm particle size, 100 mm × 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile (75:25, v/v, pH 3.5) at flow rate of 0.5 mL min-1. The influences of mobile phase composition, flow rate and pH on chromatographic resolution were investigated. The total chromatographic analysis time was as short as 2 min with excellent resolution. Detection and quantification of the target compounds were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes. The performance of the method was evaluated and very low limits of detection less than 0.09 μg g-1, excellent coefficient correlation (r2 > 0.999) with liner range over a concentration range of 0.1-1.0 μg g-1 for both L-ascorbic acid and acetylsalicylic acid, and good intraday and interday precisions (relative standard deviations (R.S.D.) <3%), were obtained. Comparison of system performance with traditional liquid chromatography-photo diode array detector (HPLC-PDA) was made with respect to analysis time, sensitivity, linearity and precisions. The proposed UPLC-MS/MS method was found to be reproducible and appropriate for quantitative analysis of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet.

  10. Silymarin in liposomes and ethosomes: pharmacokinetics and tissue distribution in free-moving rats by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chang, Li-Wen; Hou, Mei-Ling; Tsai, Tung-Hu

    2014-12-03

    The aim of this study was to prepare silymarin formulations (silymarin entrapped in liposomes and ethosomes, formulations referred to as LSM and ESM, respectively) to improve oral bioavailability of silymarin and evaluate its tissue distribution by liquid chromatography with tandem mass spectrometry (LC-MS/MS) in free-moving rats. Silibinin is the major active constituent of silymarin, which is the main component to be analyzed. A rapid, sensitive, and repeatable LC-MS/MS method was developed and validated in terms of precision, accuracy, and extraction recovery. Furthermore, the established method was applied to study the pharmacokinetics and tissue distribution of silymarin in rats. The size, ζ potential, and drug release of the formulations were characterized. These results showed that the LSM and ESM encapsulated formulations of silymarin may provide more efficient tissue distribution and increased oral bioavailability, thus improving its therapeutic bioactive properties in the body.

  11. Comparison of green sample preparation techniques in the analysis of pyrethrins and pyrethroids in baby food by liquid chromatography-tandem mass spectrometry.

    PubMed

    Petrarca, Mateus Henrique; Ccanccapa-Cartagena, Alexander; Masiá, Ana; Godoy, Helena Teixeira; Picó, Yolanda

    2017-05-12

    A new selective and sensitive liquid chromatography triple quadrupole mass spectrometry method was developed for simultaneous analysis of natural pyrethrins and synthetic pyrethroids residues in baby food. In this study, two sample preparation methods based on ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) and salting-out assisted liquid-liquid extraction (SALLE) were optimized, and then, compared regarding the performance criteria. Appropriate linearity in solvent and matrix-based calibrations, and suitable recoveries (75-120%) and precision (RSD values≤16%) were achieved for selected analytes by any of the sample preparation procedures. Both methods provided the analytical selectivity required for the monitoring of the insecticides in fruit-, cereal- and milk-based baby foods. SALLE, recognized by cost-effectiveness, and simple and fast execution, provided a lower enrichment factor, consequently, higher limits of quantification (LOQs) were obtained. Some of them too high to meet the strict legislation regarding baby food. Nonetheless, the combination of ultrasound and DLLME also resulted in a high sample throughput and environmental-friendly method, whose LOQs were lower than the default maximum residue limit (MRL) of 10μgkg -1 set by European Community for baby foods. In the commercial baby foods analyzed, cyhalothrin and etofenprox were detected in different samples, demonstrating the suitability of proposed method for baby food control. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Preparation of [13C3]-melamine and [13C3]-cyanuric acid and their application to the analysis of melamine and cyanuric acid in meat and pet food using liquid chromatography-tandem mass spectrometry.

    PubMed

    Varelis, P; Jeskelis, R

    2008-10-01

    For the determination of melamine and cyanuric acid the labelled internal standards [(13)C(3)]-melamine and [(13)C(3)]-cyanuric acid were synthesized using the common substrate [(13)C(3)]-cyanuric chloride by reaction with ammonia and acidified water, respectively. Standards with excellent isotopic and chemical purities were obtained in acceptable yields. These compounds were used to develop an isotope dilution liquid chromatography/mass spectrometry (LC/MS) method to determine melamine and cyanuric acid in catfish, pork, chicken, and pet food. The method involved extraction into aqueous methanol, liquid-liquid extraction and ion exchange solid phase clean-up, with normal phase high-performance liquid chromatography (HPLC) in the so-called hydrophilic interaction mode. The method had a limit of detection (LOD) of 10 microg kg(-1) for both melamine and cyanuric acid in the four foods with a percentage coefficient of variation (CV) of less than 10%. The recovery of the method at this level was in the range of 87-110% and 96-110% for melamine and cyanuric acid, respectively.

  13. Coenzyme Q10 quantification in muscle, fibroblasts and cerebrospinal fluid by liquid chromatography/tandem mass spectrometry using a novel deuterated internal standard.

    PubMed

    Duberley, Kate E C; Hargreaves, Iain P; Chaiwatanasirikul, Korn-Anong; Heales, Simon J R; Land, John M; Rahman, Shamima; Mills, Kevin; Eaton, Simon

    2013-05-15

    Neurological dysfunction is common in primary coenzyme Q10 (2,3-dimethoxy, 5-methyl, 6-polyisoprene parabenzoquinone; CoQ10 ; ubiquinone) deficiencies, the most readily treatable subgroup of mitochondrial disorders. Therapeutic benefit from CoQ10 supplementation has also been noted in other neurodegenerative diseases. CoQ10 can be measured by high-performance liquid chromatography (HPLC) in plasma, muscle or leucocytes; however, there is no reliable method to quantify CoQ10 in cerebrospinal fluid (CSF). Additionally, many methods use CoQ9 , an endogenous ubiquinone in humans, as an internal standard. Deuterated CoQ10 (d6 -CoQ10 ) was synthesised by a novel, simple, method. Total CoQ10 was measured by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using d6 -CoQ10 as internal standard and 5 mM methylamine as an ion-pairing reagent. Chromatography was performed using a Hypsersil GOLD C4 column (150 × 3 mm, 3 µm). CoQ10 levels were linear over a concentration range of 0-200 nM (R(2) = 0.9995). The lower limit of detection was 2 nM. The inter-assay coefficient of variation (CV) was 3.6% (10 nM) and 4.3% (20 nM), and intra-assay CV 3.4% (10 nM) and 3.6% (20 nM). Reference ranges were established for CoQ10 in CSF (5.7-8.7 nM; n = 17), fibroblasts (57.0-121.6 pmol/mg; n = 50) and muscle (187.3-430.1 pmol/mg; n = 15). Use of d6 -CoQ10 internal standard has enabled the development of a sensitive LC/MS/MS method to accurately determine total CoQ10 levels. Clinical applications of CSF CoQ10 determination include identification of patients with cerebral CoQ10 deficiency, and monitoring CSF CoQ10 levels following supplementation. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Ion-exchange solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for the determination of veterinary drugs in organic fertilizers.

    PubMed

    Zhao, Zhiyong; Zhang, Yanmei; Xuan, Yanfang; Song, Wei; Si, Wenshuai; Zhao, Zhihui; Rao, Qinxiong

    2016-06-01

    The analysis of veterinary drugs in organic fertilizers is crucial for an assessment of potential risks to soil microbial communities and human health. We develop a robust and sensitive method to quantitatively determine 19 veterinary drugs (amantadine, sulfonamides and fluoroquinolones) in organic fertilizers. The method involved a simple solid-liquid extraction step using the combination of acetonitrile and McIlvaine buffer as extraction solvent, followed by cleanup with a solid-phase extraction cartridge containing polymeric mixed-mode anion-exchange sorbents. Ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was used to separate and detect target analytes. We particularly focused on the optimization of sample clean-up step: different diluents and dilution factors were tested. The developed method was validated in terms of linearity, recovery, precision, sensitivity and specificity. The recoveries of all the drugs ranged from 70.9% to 112.7% at three concentration levels, with the intra-day and inter-day relative standard deviation lower than 15.7%. The limits of quantification were between 1.0 and 10.0μg/kg for all the drugs. Matrix effect was minimized by matrix-matched calibration curves. The analytical method was successfully applied for the survey of veterinary drugs contamination in 20 compost samples. The results indicated that fluoroquinolones had higher incidence rate and mean concentration levels ranging from 31.9 to 308.7μg/kg compared with other drugs. We expect the method will provide the basis for risk assessment of veterinary drugs in organic fertilizers. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A novel liquid chromatography/tandem mass spectrometry method for the quantification of glycine as biomarker in brain microdialysis and cerebrospinal fluid samples within 5min.

    PubMed

    Voehringer, Patrizia; Fuertig, René; Ferger, Boris

    2013-11-15

    Glycine is an important amino acid neurotransmitter in the central nervous system (CNS) and a useful biomarker to indicate biological activity of drugs such as glycine reuptake inhibitors (GRI) in the brain. Here, we report how a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the fast and reliable analysis of glycine in brain microdialysates and cerebrospinal fluid (CSF) samples has been established. Additionally, we compare this method with the conventional approach of high performance liquid chromatography (HPLC) coupled to fluorescence detection (FD). The present LC-MS/MS method did not require any derivatisation step. Fifteen microliters of sample were injected for analysis. Glycine was detected by a triple quadrupole mass spectrometer in the positive electrospray ionisation (ESI) mode. The total running time was 5min. The limit of quantitation (LOQ) was determined as 100nM, while linearity was given in the range from 100nM to 100μM. In order to demonstrate the feasibility of the LC-MS/MS method, we measured glycine levels in striatal in vivo microdialysates and CSF of rats after administration of the commercially available glycine transporter 1 (GlyT1) inhibitor LY 2365109 (10mg/kg, p.o.). LY 2365109 produced 2-fold and 3-fold elevated glycine concentrations from 1.52μM to 3.6μM in striatal microdialysates and from 10.38μM to 36μM in CSF, respectively. In conclusion, we established a fast and reliable LC-MS/MS method, which can be used for the quantification of glycine in brain microdialysis and CSF samples in biomarker studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Polydopamine-coated magnetic nanoparticles for isolation and enrichment of estrogenic compounds from surface water samples followed by liquid chromatography-tandem mass spectrometry determination.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2016-06-01

    Estrogens, phytoestrogens, and mycoestrogens may enter into the surface waters from different sources, such as effluents of municipal wastewater treatment plants, industrial plants, and animal farms and runoff from agricultural areas. In this work, a multiresidue analytical method for the determination of 17 natural estrogenic compounds, including four steroid estrogens, six mycoestrogens, and seven phytoestrogens, in river water samples has been developed. (Fe3O4)-based magnetic nanoparticles coated by polydopamine (Fe3O4@pDA) were used for dispersive solid-phase extraction, and the final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The Fe3O4 magnetic nanoparticles were prepared by a co-precipitation procedure, coated by pDA, and characterized by scanning electron microscopy, infrared spectroscopy, and elemental analysis. The sample preparation method was optimized in terms of extraction recovery, matrix effect, selectivity, trueness, precision, method limits of detection, and method limits of quantification (MLOQs). For all the 17 analytes, recoveries were >70 % and matrix effects were below 30 % when 25 mL of river water sample was treated with 90 mg of Fe3O4@pDA nanoparticles. Selectivity was tested by spiking river water samples with 50 other compounds (mycotoxins, antibacterials, conjugated hormones, UV filters, alkylphenols, etc.), and only aflatoxins and some benzophenones showed recoveries >60 %. This method proved to be simple and robust and allowed the determination of natural estrogenic compounds belonging to different classes in surface waters with MLOQs ranging between 0.003 and 0.1 μg L(-1). Graphical Abstract Determination of natural estrogenic compounds in water by magnetic solid phase extraction followed by liquid chromatography-tandem mass spectrometry analysis.

  17. Micro-pulverized extraction pretreatment for highly sensitive analysis of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol in hair by liquid chromatography/tandem mass spectrometry.

    PubMed

    Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2015-11-30

    A primary metabolite of Δ(9) -tetrahydrocannabinol, 11-nor-9-carboxytetrahydrocannabinol (THC-COOH), serves as an effective indicator for cannabis intake. According to the recommendations of the Society of Hair Testing, at least 0.2 pg/mg of THC-COOH (cut-off level) must be present in a hair sample to constitute a positive result in a drug test. Typically, hair is digested with an alkaline solution and is subjected to gas chromatography/tandem mass spectrometry (GC/MS/MS) with negative ion chemical ionization (NICI). It is difficult to quantify THC-COOH at the cut-off level using liquid chromatography/tandem mass spectrometry (LC/MS/MS) without acquisition of second-generation product ions in triple quadrupole-ion trap mass spectrometers, because large amounts of matrix components in the low-mass range produced by digestion interfere with the THC-COOH peak. Using the typical pretreatment method (alkaline dissolution) and micro-pulverized extraction (MPE) with a stainless bullet, we compared the quantification of THC-COOH using GC/MS/MS and LC/MS/MS. MPE reduced the amount of matrix components in the low-mass range and enabled the quantification of THC-COOH at 0.2 pg/mg using a conventional triple quadrupole liquid chromatograph coupled to a mass spectrometer. On the other hand, the MPE pretreatment was unsuitable for GC/MS/MS, probably due to matrix components in the high-mass range. The proper combination of pretreatments and instrumental analyses was shown to be important for detecting trace amounts of THC-COOH in hair. In MPE, samples can be prepared rapidly, and LC/MS/MS is readily available, unlike GC/MS/MS with NICI. The combination of MPE and LC/MS/MS might therefore be used in the initial screening for THC-COOH in hair prior to confirmatory analysis using GC/MS/MS with NICI. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  19. Optimization of clean extraction methods to isolate carotenoids from the microalga Neochloris oleoabundans and subsequent chemical characterization using liquid chromatography tandem mass spectrometry.

    PubMed

    Castro-Puyana, María; Herrero, Miguel; Urreta, Iratxe; Mendiola, Jose A; Cifuentes, Alejandro; Ibáñez, Elena; Suárez-Alvarez, Sonia

    2013-05-01

    A novel experimental design was used to optimize the extraction of carotenoids from Neochloris oleoabundans using pressurized liquid extraction with food-grade solvents such as ethanol and limonene. Experimental factors, including the extraction temperature and the solvent composition, were optimized using a three-level factorial design. The response variables extraction yield and total amount of carotenoids were assessed. The statistical analysis of the results provided mathematical models to predict the behavior of the responses as a function of the factors involved in the process. The optimum conditions predicted by the model developed in this study were 112 °C as the extraction temperature and 100% ethanol as the extraction solvent. Chemical characterization of the extracts obtained was performed by means of high-performance liquid chromatography-tandem mass spectrometry. The results obtained demonstrated that, under certain growth conditions (photoautotrophically cultured in a medium supplemented with 0.3 g L(-1) KNO3), N. oleoabundans accumulated significant total amounts of the carotenoids (from 57.4 to 120.2 mg carotenoids per gram of extract depending on the extraction conditions), mainly lutein, cantaxanthin, zeaxanthin, and astaxanthin monoesters and diesters.

  20. Simple and quick determination of analgesics and other contaminants of emerging concern in environmental waters by on-line solid phase extraction coupled to liquid chromatography-tandem mass spectrometry.

    PubMed

    Ferrer-Aguirre, Alejandra; Romero-González, Roberto; Vidal, J L Martínez; Frenich, Antonia Garrido

    2016-05-13

    A simple and quick analytical method has been developed for the determination of pharmaceutical compounds in water. An on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been optimized to determine 7 contaminants of emerging concern in environmental waters at ngL(-1) levels. This procedure requires minimal sample handling and small sample volume (900μL) with a total running time of 18min. Several SPE parameters were evaluated and optimized in order to achieve a high sample throughput. Therefore sample volume, carryover and reusability of the cartridges were evaluated. Performance characteristics were evaluated and good linearity was obtained (R(2)>0.98). Recoveries were evaluated in spiked samples at three concentrations and the values ranged from 71 to 104%. Intra and inter-day precision was lower than 10 and 13% respectively. Limits of quantification were equal to or lower than 10ngL(-1), except for 1,7-dimethylxanthine (20ngL(-1)) and ibuprofen (50ngL(-1)). The method was applied to 20 environmental water samples, and ibuprofen was the compound most widely detected at concentrations up to 42.06μgL(-1), whereas the other compounds were detected in fewer samples at lower concentrations (up to 15.99μgL(-1)). Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Analysis of 19-nortestosterone residue in animal tissues by ion-trap gas chromatography-tandem mass spectrometry*

    PubMed Central

    Jiang, Jin-qing; Zhang, Lei; Li, Guang-ling; Zhang, Hai-tang; Yang, Xue-feng; Liu, Jun-wei; Li, Ren-feng; Wang, Zi-liang; Wang, Jian-hua

    2011-01-01

    A rapid sample treatment procedure for the gas chromatography-tandem mass spectrometry (GC-MS) determination of 19-nortestosterone (19-NT) in animal tissues has been developed. In our optimized procedures, enzymatic hydrolysis with β-glucuronidase from Escherichia coli was performed in an acetate buffer (pH 5.2, 0.2 mol/L). Next, the homogenate was mixed with methanol and heated at 60 °C for 15 min, then placed in an ice-bath at −18 °C for 2 h. After liquid-liquid extraction with n-hexane, the analytes were subjected to a normal-phase solid phase extraction (SPE) C18 cartridge for clean-up. The dried organic extracts were derivatized with heptafluorobutyric anhydride (HFBA), and then the products were injected into GC-MS. Using electron impact mass spectrometry (EI-MS) with positive chemical ionization (PCI), four diagnostic ions (m/z 666, 453, 318, and 306) were determined. A standard calibration curve over the concentration range of 1–20 ng/g was reached, with Y=467 084X−68 354 (R 2=0.999 7) for 19-NT, and the detection limit was 0.3 ng. When applied to spiked samples collected from bovine and ovine, the recoveries ranged from 63% to 101% with relative standard deviation (RSD) between 2.7% and 8.9%. The procedure is a highly efficient, sensitive, and more economical method which offers considerable potential to resolve cases of suspected nandrolone doping in husbandry animals. PMID:21634039

  2. Liquid to liquid extraction and liquid chromatography-tandem mass spectrometry determination of hainanmycin in feed.

    PubMed

    Wang, Ze Ping; Shen, Jian Zhong; Linhardt, Robert J; Jiang, Hui; Cheng, Lin Li

    2017-03-01

    Hainanmycin is a new veterinary polyether antibiotic and has few sensitive analytical method in present days. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) relying on multiple reaction monitoring (MRM) detection was developed for analysis of hainanmycin in animal feed. Feed samples were extracted with ethyl acetate and purified by two steps of liquid-liquid extraction (LLE) to get rid of water solvable matrix and lipids one by one. The final simple was analyzed by LC-MS/MS. The LC mobile phase was composed of 0.1% aqueous formic acid and 0.1% formic acidified acetonitrile by gradient elution. Average recoveries ranged from 74.22% to 87.85%, as determined by spiking with 2.0 (LOQ) ∼2500μgkg -1 of hainanmycin. The inter-day and intra-day coefficient of variation was 9.21% to 11.77% and 7.67% to 13.49%, respectively. The limit of detection (LOD) and the limit of quantitation (LOQ) were 0.36μgkg -1 and 2.0μgkg -1 , respectively. Copyright © 2016. Published by Elsevier B.V.

  3. [Determination of 250 pesticide residues in vegetables using QuEChERS-ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Aizhi; Wang, Quanlin; Cao, Lili; Li, Yu; Shen, Hao; Shen, Jian; Zhang, Shufen; Man, Zhengyin

    2016-02-01

    A multiresidue analytical method for the determination of 250 pesticide residues in vegetables was developed by using QuEChERS-ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with acetonitrile containing 1% (v/v) acetic acid, purified by a mixed sorbent of MgSO4, primary secondary amine (PSA), graphitized carbon black (GCB) and C18, separated on a Waters ACQUITY™ UPLC BEH C18 column (100 mm x 2. 1 mm, 1.7 µm) and detected by UPLC-MS/MS. Anhydrous magnesium sulfate was used as a dewatering agent. The effects of the amounts of MgSO4, PSA, GCB and C18 added on the recoveries of 250 pesticides were investigated. The results showed that the purification effect was best when 300 mg MgSO4, 200 mg PSA, 10 mg GCB and 100 mg C18 in 2 mL of the extract were added. For the 250 pesticide residues, the limits of detection (LODs) of the method were from 0. 01 to 50. 00 g/kg. The recoveries obtained ranged from 60. 1% to 120% at three spiked levels in Chinese chives with the relative standard deviations between 3. 5% and 19. 5% using matrix matched external standard method. The results showed that the method is able to meet requirements of the multiresidue detection of the 250 pesticides in vegetable. The method has the advantages of rapidity, simplicity, high sensitivity and better purification effect. It is suitable for the rapid determination of the common pesticides in vegetables, and it provides a strong guarantee for the risk assessments of the quality and safety of vegetables.

  4. Optimization and application of parallel solid-phase extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry for the determination of 11 aminoglycoside residues in honey and royal jelly.

    PubMed

    Wang, Xinran; Yang, Shupeng; Li, Yi; Zhang, Jinzhen; Jin, Yue; Zhao, Wen; Zhang, Yongxin; Huang, Jingping; Wang, Peng; Wu, Cuiling; Zhou, Jinhui

    2018-03-23

    A robust and sensitive method of solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established and performed for the simultaneous determination of eleven aminoglycosides (AGs) in royal jelly and honey. After sample extraction by a phosphate buffer containing trichloroacetic acid (TCA) and ethylenediaminetetracetic acid disodium salt (Na 2 EDTA), the extraction solution was subjected to a parallel solid-phase extraction for clean-up prior to the LC-MS/MS analysis. The same method was applied to analyze two completely different matrices, honey and royal jelly. Good sensitivity, repeatability, and recovery were obtained by using the mobile phase without an ion-pairing reagent such as heptafluorobutyric acid (HFBA) or sodium heptanesulfonate. The calibration curves of the honey and royal jelly samples exhibited a good linear response (R 2  > 0.99) at six concentrations in the range of 10-1000 μg/mL. The limit of quantification (LOQ) of the AGs ranged from 10 to 25 μg/kg in the honey and from 12.5 to 25 μg/kg in the royal jelly. The recoveries of the AGs for the honey and royal jelly samples were in the range of 79.48% to 108.95% and 74.61% to 113.70% respectively and the relative standard deviations (RSDs) were between 1.23% and 9.59%, and between 1.51% and 9.98%, respectively. The proposed approach has been allowed in China as a reference method for the simultaneous determination of eleven AGs in honey and royal jelly. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Simultaneous analysis of aminoglycosides with many other classes of drug residues in bovine tissues by ultrahigh-performance liquid chromatography-tandem mass spectrometry using an ion-pairing reagent added to final extracts.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R

    2018-01-01

    The way to maximize scope of analysis, sample throughput, and laboratory efficiency in the monitoring of veterinary drug residues in food animals is to determine as many analytes as possible as fast as possible in as few methods as possible. Capital and overhead expenses are also reduced by using fewer instruments in the overall monitoring scheme. Traditionally, the highly polar aminoglycoside antibiotics require different chromatographic conditions from other classes of drugs, but in this work, we demonstrate that an ion-pairing reagent (sodium 1-heptanesulfonate) added to the combined final extracts from two sample preparation methods attains good separation of 174 targeted drugs, including 9 aminoglycosides, in the same 10.5-min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The full method was validated in bovine kidney, liver, and muscle tissues according to US regulatory protocols, and 137-146 (79-84%) of the drugs gave between 70 and 120% average recoveries with ≤ 25% RSDs in the different types of tissues spiked at 0.5, 1, and 2 times the regulatory levels of interest (10-1000 ng/g depending on the drug). This method increases sample throughput and the possible number of drugs monitored in the US National Residue Program, and requires only one UHPLC-MS/MS method and instrument for analysis rather than two by the previous scheme. Graphical abstract Outline of the streamlined approach to monitor 174 veterinary drugs, including aminoglycosides, in bovine tissues by combining two extracts of the same sample with an ion-pairing reagent for analysis by UHPLC-MS/MS.

  6. Androgen profiling by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in healthy normal-weight ovulatory and anovulatory late adolescent and young women.

    PubMed

    Fanelli, Flaminia; Gambineri, Alessandra; Belluomo, Ilaria; Repaci, Andrea; Di Lallo, Valentina Diana; Di Dalmazi, Guido; Mezzullo, Marco; Prontera, Olga; Cuomo, Gaia; Zanotti, Laura; Paccapelo, Alexandro; Morselli-Labate, Antonio Maria; Pagotto, Uberto; Pasquali, Renato

    2013-07-01

    Physiological transient imbalance typical of adolescence needs to be distinguished from hyperandrogenism-related dysfunction. The accurate determination of circulating androgens is the best indicator of hyperandrogenism. However, reliable reference intervals for adolescent and young women are not available. The aim of the study was to define androgen reference intervals in young women and to analyze the impact of the menstrual phase and ovulation efficiency over the androgen profile as assessed by reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. Female high school students aged 16-19 years were included in the study. The study was performed on reference subjects properly selected among an unbiased population. Normal-weight, drug and disease free, eumenorrheic females with no signs of hyperandrogenism were included. The steroid hormone profile was determined by a validated in-house LC-MS/MS method. A statistical estimation of overall and menstrual phase-specific reference intervals was performed. A subgroup of anovulatory females was identified based on progesterone circulating levels. The impact of ovulation efficiency over hormonal profile was analyzed. A total of 159 females satisfied healthy criteria. Androgen levels did not vary according to menstrual phase, but a significantly higher upper reference limit was found for T in the luteal phase compared to the follicular phase. Higher T and androstenedione levels were observed in anovulatory compared to ovulatory females, paralleled by higher LH and FSH and lower 17-hydroxyprogesterone and 17β-estradiol levels. This is the first study providing LC-MS/MS-based, menstrual phase-specific reference intervals for the circulating androgen profile in young females. We identified a subgroup of anovulatory healthy females characterized by androgen imbalance.

  7. Identification and quantification of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide (THC-COOH-glu) in hair by ultra-performance liquid chromatography tandem mass spectrometry as a potential hair biomarker of cannabis use.

    PubMed

    Pichini, Simona; Marchei, Emilia; Martello, Simona; Gottardi, Massimo; Pellegrini, Manuela; Svaizer, Fiorenza; Lotti, Andrea; Chiarotti, Marcello; Pacifici, Roberta

    2015-04-01

    We developed and validated an ultra-high-pressure liquid chromatography-tandem mass spectrometry method to identify and quantify 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in hair of cannabis consumers. After hair washing with methyl alcohol and diethyl ether and subsequent addition of amiodarone as internal standard hair samples were treated with 500 μl VMA-T M3 buffer reagent for 1 h at 100 °C. After cooling, 10 μl VMA-T M3 extract were injected into chromatographic system. Chromatographic separation was carried out on a reversed phase column using a linear gradient elution with two solvents: 5 mM ammonium formate pH 3.0 (solvent A) and 0.1% formic acid in acetonitrile (solvent B). The flow rate was kept constant at 0.4 ml/min during the analysis. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring mode via positive electrospray ionization. Linear calibration curves were obtained for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide with correlation coefficients (r(2)) of 0.99 and a limit of quantification of 0.25 pg/mg hair. Analytical recovery was between 79.6% and 100.7% and intra- and inter-assay imprecision and inaccuracy were always lower than 15%. Ultra-high-pressure liquid chromatography-tandem mass spectrometry analysis of 20 different hair samples of cannabis consumers disclosed the presence of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in the range of 0.5-8.6 pg/mg hair. These data provided a good start to consider 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide as alternative hair biomarker of cannabis consumption. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. High-speed homogenization coupled with microwave-assisted extraction followed by liquid chromatography-tandem mass spectrometry for the direct determination of alkaloids and flavonoids in fresh Isatis tinctoria L. hairy root cultures.

    PubMed

    Jiao, Jiao; Gai, Qing-Yan; Zhang, Lin; Wang, Wei; Luo, Meng; Zu, Yuan-Gang; Fu, Yu-Jie

    2015-06-01

    A new, simple and efficient analysis method for fresh plant in vitro cultures-namely, high-speed homogenization coupled with microwave-assisted extraction (HSH-MAE) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS)-was developed for simultaneous determination of six alkaloids and eight flavonoids in Isatis tinctoria hairy root cultures (ITHRCs). Compared with traditional methods, the proposed HSH-MAE offers the advantages of easy manipulation, higher efficiency, energy saving, and reduced waste. Cytohistological studies were conducted to clarify the mechanism of HSH-MAE at cellular/tissue levels. Moreover, the established LC-MS/MS method showed excellent linearity, precision, repeatability, and reproducibility. The HSH-MAE-LC-MS/MS method was also successfully applied for screening high-productivity ITHRCs. Overall, this study opened up a new avenue for the direct determination of secondary metabolic profiles from fresh plant in vitro cultures, which is valuable for improving quality control of plant cell/organ cultures and sheds light on the metabolomic analysis of biological samples. Graphical Abstract HSH-MAE-LC-MS/MS opened up a new avenue for the direct determination of alkaloids and flavonoids in fresh Isatis tinctoria hairy root cultures.

  9. Synthetic Peptide Arrays for Pathway-Level Protein Monitoring by Liquid Chromatography-Tandem Mass Spectrometry*

    PubMed Central

    Hewel, Johannes A.; Liu, Jian; Onishi, Kento; Fong, Vincent; Chandran, Shamanta; Olsen, Jonathan B.; Pogoutse, Oxana; Schutkowski, Mike; Wenschuh, Holger; Winkler, Dirk F. H.; Eckler, Larry; Zandstra, Peter W.; Emili, Andrew

    2010-01-01

    Effective methods to detect and quantify functionally linked regulatory proteins in complex biological samples are essential for investigating mammalian signaling pathways. Traditional immunoassays depend on proprietary reagents that are difficult to generate and multiplex, whereas global proteomic profiling can be tedious and can miss low abundance proteins. Here, we report a target-driven liquid chromatography-tandem mass spectrometry (LC-MS/MS) strategy for selectively examining the levels of multiple low abundance components of signaling pathways which are refractory to standard shotgun screening procedures and hence appear limited in current MS/MS repositories. Our stepwise approach consists of: (i) synthesizing microscale peptide arrays, including heavy isotope-labeled internal standards, for use as high quality references to (ii) build empirically validated high density LC-MS/MS detection assays with a retention time scheduling system that can be used to (iii) identify and quantify endogenous low abundance protein targets in complex biological mixtures with high accuracy by correlation to a spectral database using new software tools. The method offers a flexible, rapid, and cost-effective means for routine proteomic exploration of biological systems including “label-free” quantification, while minimizing spurious interferences. As proof-of-concept, we have examined the abundance of transcription factors and protein kinases mediating pluripotency and self-renewal in embryonic stem cell populations. PMID:20467045

  10. On-line solid phase extraction-liquid chromatography-tandem mass spectrometry for insect repellent residue analysis in surface waters using atmospheric pressure photoionization.

    PubMed

    Molins-Delgado, Daniel; García-Sillero, Daniel; Díaz-Cruz, M Silvia; Barceló, Damià

    2018-04-06

    Insect repellents (IRs) are a group of organic chemicals whose function is to prevent the ability of insects of landing in a surface. These compounds have been found in the environment and may pose a risk to non-target organisms. In this study, an on-line solid phase extraction - high performance liquid chromatography-tandem mass spectrometry multiresidue method was developed using an atmospheric photoionization source (SPE-HPLC-(APPI)-MS/MS). The use of the APPI as an alternative ionization technique to electrospray (ESI) and atmospheric pressure chemical ionization (APCI) allowed expanding the range of analytical techniques suitable for the analysis of IRs, so far relied in gas chromatography. High sensitivity and precision was reached with method limits of quantification between 0.2 and 4.6 ng l -1 and interday and intraday precision equal or below 15%. The validated method was applied to the study of surface water samples from three European river basins with different flow regime (Adige River in Italy, Sava River in the Balkans, and Evrotas River in Greece). The results showed that two IRs (DEET and Bayrepel) were ubiquitous in the Sava and Evrotas basins, reaching concentrations as high as 105 μg l -1 of Bayrepel in the Sava River, and 5 μg l -1 of DEET in the Evrotas River. Densely populated areas and effluent waste waters are pointed out as the responsible for this pollution. In the alpine river Adige, only three samples showed low levels of IRs (6.01-37.8 ng l -1 ). The concentrations measured were used to perform an environmental risk assessment based on the hazard quotients (HQs) estimation approach by using the chronic and acute eco-toxicity data available. The results revealed that despite the high frequency and eventually high concentrations of these IRs determined in the three basins, only few sites were at risk, with 1 < HQs < 3.3. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  11. Extraction and Liquid Chromatography-Tandem Mass Spectrometry Detection of 3-Monochloropropanediol Esters and Glycidyl Esters in Infant Formula.

    PubMed

    Leigh, Jessica K; MacMahon, Shaun

    2016-12-14

    A method was developed for the extraction of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD) and glycidol from infant formula, followed by quantitative analysis of the extracts using liquid chromatography-tandem mass spectrometry (LC-MS/MS). These process-induced chemical contaminants are found in refined vegetable oils, and studies have shown that they are potentially carcinogenic and/or genotoxic, making their presence in edible oils (and processed foods containing these oils) a potential health risk. The extraction procedure involves a liquid-liquid extraction, where powdered infant formula is dissolved in water and extracted with ethyl acetate. Following shaking, centrifugation, and drying of the organic phase, the resulting fat extract is cleaned-up using solid-phase extraction and analyzed by LC-MS/MS. Method performance was confirmed by verifying the percent recovery of each 3-MCPD and glycidyl ester in a homemade powdered infant formula reference material. Average ester recoveries in the reference material ranged from 84.9 to 109.0% (0.6-9.5% RSD). The method was also validated by fortifying three varieties of commercial infant formulas with a 3-MCPD and glycidyl ester solution. Average recoveries of the esters across all concentrations and varieties of infant formula ranged from 88.7 to 107.5% (1.0-9.5% RSD). Based on the validation results, this method is suitable for producing 3-MCPD and glycidyl ester occurrence data in all commercially available varieties of infant formula.

  12. Simultaneous analysis of aminoglycosides with many other classes of drug residues in bovine tissues by ultrahigh-performance liquid chromatography-tandem mass spectrometry using an ion-pairing reagent added to final extracts

    USDA-ARS?s Scientific Manuscript database

    The way to maximize scope of analysis, sample throughput, and laboratory efficiency in the monitoring of veterinary drug residues in food animals is to determine as many analytes as possible as fast as possible in as few methods as possible. Capital and overhead expenses are also reduced by using f...

  13. Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

    PubMed

    Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H

    2016-12-01

    In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. High-throughput screening for multi-class veterinary drug residues in animal muscle using liquid chromatography/tandem mass spectrometry with on-line solid-phase extraction.

    PubMed

    Tang, Hubert Po-On; Ho, Clare; Lai, Shirley Sau-Ling

    2006-01-01

    A rapid qualitative method using on-line column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for screening 13 target veterinary drugs: four macrolides - erythromycin A, josamycin (leucomycin A3), kitasamycin (leucomycin A5), and tylosin A; six (fluoro)quinolones - ciprofloxacin, danofloxacin, enrofloxacin, flumequine, oxolinic acid, and sarafloxacin; and lincomycin, virginiamycin M1, and trimethoprim in different animal muscles. Clindamycin, norfloxacin, nalidixic acid, oleandomycin, ormetoprim, and roxithromycin were used as the internal standards. After simple deproteination and analyte extraction of muscle samples using acetonitrile, the supernatant was subjected to on-line cleanup and direct analysis by LC/MS/MS. On-line cleanup with an extraction cartridge packed with hydrophilic-hydrophobic polymer sorbent followed by fast LC using a short C18 column resulted in a total analysis cycle of 6 min for 19 drugs. This screening method considerably reduced the time and the cost for the quantitative and confirmatory analyses. The application of a control point approach was also introduced and explained. Copyright (c) 2006 John Wiley & Sons, Ltd.

  15. Quantitation of phlorizin and phloretin using an ultra high performance liquid chromatography-electrospray ionization tandem mass spectrometric method.

    PubMed

    Lijia, Xu; Guo, Jianru; Chen, QianQian; Baoping, Jiang; Zhang, Wei

    2014-06-01

    A sensitive and selective ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method for the determination of phlorizin and phloretin in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.02% formic acid), using a gradient procedure. The analytes and internal standard dihydroquercetin were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 9.2%. The accuracy determined at three concentrations was within ± 7.3% in terms of relative error. The total run time was 12.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of phlorizin and phloretin in various biological fluids. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. In vivo study on the neurotransmitters and their metabolites change in depressive disorder rat plasma by ultra high performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Zhao, Longshan; Zheng, Shuning; Su, Guangyue; Lu, Xiumei; Yang, Jingyu; Xiong, Zhili; Wu, Chunfu

    2015-04-15

    A sensitive and versatile, ultra-high performance, liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method coupled to pre-column derivatization for the simultaneous determination of 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA), dopamine (DA), norepinephrine (NE), homovanillic acid (HVA), γ-aminobutyric acid (GABA) and glutamic acid (Glu) was developed and validated in rat plasma. The analytes were dansylated under strong alkaline conditions after protein precipitation extraction, which were analyzed on a BEH C18 column using a gradient elution. The lower limit of quantification (LLOQ) values for 5-HT, 5-HIAA, DA, NE, HVA, GABA and Glu were 1.00, 1.00, 0.991, 0.992, 1.02, 1000, and 5030 pmol/mL, respectively. Good linearity was obtained (r > 0.99) and the intra- and inter-day precisions of the method (relative standard deviation, RSD%) were lower than 12%. The method was novel, sensitive and specific which can provide an alternative method for the quantification of neurotransmitters and their metabolites in plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Comparative analysis of sixteen flavonoids from different parts of Sophora flavescens Ait. by ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Weng, Zebin; Zeng, Fei; Zhu, Zhenhua; Qian, Dawei; Guo, Sheng; Wang, Hanqing; Duan, Jin-Ao

    2018-07-15

    The root of Sophora flavescens Ait. has long been used as a crude drug in China and other Asian countries for thousands of years. The quinolizidine alkaloids and flavonoids are considered as the main bioactive components in this plant. To determine the distribution and content of the flavonoids in different organs of this plant, a rapid, sensitive and reproducible method was established using ultra-high-performance liquid chromatography coupled with a triple quadrupole electrospray tandem mass spectrometry. A total of sixteen flavonoids including five different types (isoflavones, pterocarpans, flavones, flavonols and prenylflavonoids) were simultaneously determined in 10 min. The established method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery and successfully applied in the methanolic extracts of S. flavescens parts (root, stem, leaf, pod and seed). The analysis results indicated that the distribution and contents of different type of flavonoids showed remarkable differences among the five organs of S. flavescens. This study might be useful for the rational utilization of S. flavescens resource. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. [Determination of myclobutanil and difenoconazole residues in pollen and honey of litchi by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Wang, Siwei; Liu, Yanping; Sun, Haibin; DU, Lanjuan; Xu, Nengli

    2018-01-08

    An effective method was developed for the determination of two major fungicides including myclobutanil and difenoconazole residues in pollen and honey of litchi by modified QuEChERS-high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The pollen and honey samples were all extracted by acetonitrile, the pollen samples were cleaned-up by 0.9 g anhydrous magnesium sulfate (MgSO 4 ), 0.15 g primary secondary amine (PSA) and 0.15 g C 18 ; the honey samples were cleaned-up by 0.9 g MgSO 4 and 0.15 g PSA. The 0.1% (v/v) formic acid aqueous solution-acetonitrile (25:75, v/v) were used as the mobile phases. The extracts were separated on a Poroshell-120 EC-C 18 chromatographic column, the positive electrospray ion (ESI + ) source and selected ion monitoring (SIM) mode were used. The analytes were quantified by the matrix matching standard solutions. The matrix matched standard solutions of myclobutanil and difenoconazole showed good linearities in the range of 1-100 μg/L, and the correlation coefficients ( r 2 ) were all above 0.9990. The limits of detection (LODs) of myclobutanil and difenoconazole were 0.25 μg/kg and 0.50 μg/kg, respectively. The limits of quantification (LOQs) of myclobutanil and difenoconazole were 0.83 μg/kg and 1.7 μg/kg, respectively. The average recoveries of myclobutanil and difenoconazole in pollen and honey samples were 87.0%-95.2% and 90.1%-96.4% with the relative standard deviations of 1.2%-3.6% and 0.7%-4.1%, respectively. The method is quick, easy and sensitive, and it is suitable for the rapid determination and trace analysis of myclobutanil and difenoconazole in pollens and honeys of litchi. The method can provide data support for the exposure risk assessment of bees and other pollination insects.

  19. Determination of a selection of synthetic cannabinoids and metabolites in urine by UHPSFC-MS/MS and by UHPLC-MS/MS.

    PubMed

    Berg, Thomas; Kaur, Lakhwinder; Risnes, Anna; Havig, Stine Marie; Karinen, Ritva

    2016-07-01

    Two different analytical techniques, ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) and reversed phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), were used for the determination of two synthetic cannabinoids and eleven metabolites in urine; AM-2201 N-4-OH-pentyl, AM-2233, JWH-018 N-5-OH-pentyl, JWH-018 N-pentanoic acid, JWH-073 N-4-OH-butyl, JWH-073 N-butanoic acid, JWH-122 N-5-OH-pentyl, MAM-2201, MAM-2201 N-4-OH-pentyl, RCS-4 N-5-OH-pentyl, UR-144 degradant N-pentanoic acid, UR-144 N-4-OH-pentyl, and UR-144 N-pentanoic acid. Sample preparation included a liquid-liquid extraction after deconjugation with ß-glucuronidase. The UHPSFC-MS/MS method used an Acquity UPC(2 TM) BEH column with a mobile phase consisting of CO2 and 0.3% ammonia in methanol, while the UHPLC-MS/MS method used an Acquity UPLC® BEH C18 column with a mobile phase consisting of 5 mM ammonium formate (pH 10.2) and methanol. MS/MS detection was performed with positive electrospray ionization and two multiple reaction monitoring transitions. Deuterated internal standards were used for six of the compounds. Limits of quantification (LOQs) were between 0.04 and 0.4 µg/L. Between-day relative standard deviations at concentrations ≥ LOQ were ≤20%, with biases within ±19%. Recoveries ranged from 40 to 90%. Corrected matrix effects were within 100 ± 10%, except for MAM-2201 with UHPSFC-MS/MS, and for UR-144 N-pentanoic acid and MAM-2201 N-4-OH-pentyl with UHPLC-MS/MS. Elution order obtained by UHPSFC-MS/MS was almost opposite to that obtained by UHPLC-MS/MS, making this instrument setup an interesting combination for screening and confirmation analyses in forensic cases. The UHPLC-MS/MS method has, since August 2014, been successfully used for confirmation of synthetic cannabinoids in urine samples revealing a positive immunoassay screening result. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Double-sided magnetic molecularly imprinted polymer modified graphene oxide for highly efficient enrichment and fast detection of trace-level microcystins from large-volume water samples combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Pan, Sheng-Dong; Chen, Xiao-Hong; Li, Xiao-Ping; Cai, Mei-Qiang; Shen, Hao-Yu; Zhao, Yong-Gang; Jin, Mi-Cong

    2015-11-27

    Microcystins (MCs), a group of cyclic heptapeptide heaptoxins and tumor promoters, are generated by cyanobacteria occurring in surface waters, such as eutrophic lakes, rivers, and reservoirs. In this present study, a novel double-sided magnetic molecularly imprinted polymer modified graphene oxide (DS-MMIP@GO) based magnetic solid-phase extraction (MSPE) method was developed for fast, effective and selective enrichment, and recognition of trace MCs in environmental water samples combined with high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The synthesized novel DS-MMIP@GO was used as the adsorbents in this work and was carefully characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), and Raman spectra. The adsorption and desorption conditions of DS-MMIP@GO toward MCs were optimized in detail to obtain the highest binding capacity, selectivity, and release efficiency. Under the optimum conditions, the enrichment factors of the method for eight target MCs were found to be 2000. The limits of quantitation (LOQs) of the method for eight MCs were in range of 0.1-2.0ngL(-1). The double-sided MMIP modified structure provided DS-MMIP@GO with abundant adsorption sites and permitted it to exhibit excellent enrichment and selectivity toward trace-level MCs. The proposed method was successfully applied for the analysis of environmental water samples with recoveries ranging from 84.1 to 98.2%. Compared to conventional methods for MCs detection reported in literatures, the one developed in this work based on DS-MMIP@GO and LC-MS/MS showed much faster, more sensitive, and more convenient. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Fully automated analysis of four tobacco-specific N-nitrosamines in mainstream cigarette smoke using two-dimensional online solid phase extraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Jie; Bai, Ruoshi; Yi, Xiaoli; Yang, Zhendong; Liu, Xingyu; Zhou, Jun; Liang, Wei

    2016-01-01

    A fully automated method for the detection of four tobacco-specific nitrosamines (TSNAs) in mainstream cigarette smoke (MSS) has been developed. The new developed method is based on two-dimensional online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE/LC-MS/MS). The two dimensional SPE was performed in the method utilizing two cartridges with different extraction mechanisms to cleanup disturbances of different polarity to minimize sample matrix effects on each analyte. Chromatographic separation was achieved using a UPLC C18 reversed phase analytical column. Under the optimum online SPE/LC-MS/MS conditions, N'-nitrosonornicotine (NNN), N'-nitrosoanatabine (NAT), N'-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) were baseline separated with good peak shapes. This method appears to be the most sensitive method yet reported for determination of TSNAs in mainstream cigarette smoke. The limits of quantification for NNN, NNK, NAT and NAB reached the levels of 6.0, 1.0, 3.0 and 0.6 pg/cig, respectively, which were well below the lowest levels of TSNAs in MSS of current commercial cigarettes. The accuracy of the measurement of four TSNAs was from 92.8 to 107.3%. The relative standard deviations of intra-and inter-day analysis were less than 5.4% and 7.5%, respectively. The main advantages of the method developed are fairly high sensitivity, selectivity and accuracy of results, minimum sample pre-treatment, full automation, and high throughput. As a part of the validation procedure, the developed method was applied to evaluate TSNAs yields for 27 top-selling commercial cigarettes in China. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Rapid determination of phenolic compounds and alkaloids of carob flour by improved liquid chromatography tandem mass spectrometry.

    PubMed

    Ortega, Nàdia; Macià, Alba; Romero, Maria-Paz; Trullols, Esther; Morello, Jose-Ramón; Anglès, Neus; Motilva, Maria-Jose

    2009-08-26

    An improved chromatographic method was developed using ultra-performance liquid chromatography-tandem mass spectrometry to identify and quantify phenolic compounds and alkaloids, theobromine and caffeine, in carob flour samples. The developed method has been validated in terms of speed, sensitivity, selectivity, peak efficiency, linearity, reproducibility, limits of detection, and limits of quantification. The chromatographic method allows the identification and quantification of 20 phenolic compounds, that is, phenolic acids, flavonoids, and their aglycone and glucoside forms, together with the determination of the alkaloids, caffeine and theobromine, at low concentration levels all in a short analysis time of less than 20 min.

  3. A simple validated multi-analyte method for detecting drugs in oral fluid by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    PubMed

    Zheng, Yufang; Sparve, Erik; Bergström, Mats

    2018-06-01

    A UPLC-MS/MS method was developed to identify and quantitate 37 commonly abused drugs in oral fluid. Drugs of interest included amphetamines, benzodiazepines, cocaine, opiates, opioids, phencyclidine and tetrahydrocannabinol. Sample preparation and extraction are simple, and analysis times short. Validation showed satisfactory performance at relevant concentrations. The possibility of contaminated samples as well as the interpretation in relation to well-knows matrices, such as urine, will demand further study. Copyright © 2017 John Wiley & Sons, Ltd.

  4. [Simultaneous determination of four alkaloids in Corydalis decumbens (Thunb.) Pers. by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Shen, Yan; Han, Chao; Liu, Cuiping; Zhou, Yongfang; Xia, Biqi; Zhu, Zhenou; Liu, Aili

    2011-02-01

    A method for the analysis of 4 alkaloids in Corydalis decumbens (Thunb.) Pers. was developed by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-MS/MS). The sample was extracted in methanol by ultrasonic, filtered and diluted with methanol for further analysis. The analysis was performed on a C18 column (150 mm x 2.1 mm, 3.5 microm) using a gradient elution program with the mobile phase of 0.2% acetic acid solution and acetonitrile. The analyte was determined by an electrospray ionization tandem mass spectrometry in multiple reactions monitoring (MRM) mode. The qualitative and quantitative analyses were based on the retention times and characteristic ion pairs consisting of one parent ion and two fragment ions of the analyte. The limits of detection (LODs) for 4 alkaloids were in the range of 0.02 - 0.2 microg/L, and the limits of quantification (LOQs) were in the range of 0.07 - 0.66 microg/L. The average recoveries were in the range of 93.6% - 103.5% for 4 alkaloids with the relative standard deviations below 3.8%. This method is reliable, sensitive and reproducible, and it can be used for the quality control of Corydalis decumbens (Thunb.) Pers. sample.

  5. [An ultrafast liquid chromatography-tandem mass spectrometric method for simultaneous determination of common artificial synthetic pigments in cooked meat products].

    PubMed

    Chen, Xiaohong; Li, Xiaoping; Zhao, Yonggang; Pan, Shengdong; Jin, Micong

    2015-07-01

    A method based on ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) has been developed for the simultaneous determination of seven synthetic pigments in cooked meat product. After the cooked meat products were extracted by mixed extraction agent, purified by WAX column, the UFLC separation was performed on a Shim-pack XR-ODS II column (75 mm x 2.0 mm, 2.2 µm) with a linear gradient elution program of acetonitrile and ammonium acetate (AmAc, 5 mmol/L) as the mobile phase. Electrospray ionization was applied and operated in the negative ion mode. The limits of quantitation (LOQs) for the seven synthetic pigments were in the range of 0.7-5.0 µg/kg. The calibration curves showed good linearities for the seven analytes in their detection ranges, and the correlative coefficients (r) were more than 0.999. The recoveries were between 88.2%-106.5% with the RSDs in the range of 1.2%-5.0%. The method is sensitive, reproducible, quick and adapts to the simultaneous determination of the seven synthetic pigments in cooked meat product.

  6. Liquid chromatography-tandem mass spectrometry method for the analysis of N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine, a biocidal disinfectant, in dairy products.

    PubMed

    Slimani, Kahina; Pirotais, Yvette; Maris, Pierre; Abjean, Jean-Pierre; Hurtaud-Pessel, Dominique

    2018-10-01

    A novel and reliable method to quantify residual levels of N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in dairy products using ion-pairing reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and fully validated. Sample extraction was done with salting-out technique using acetonitrile and sodium chloride. For LC-MS/MS, the analyte was detected using positive electrospray ionization (ESI+) and two multiple reaction monitoring (MRM) transitions were monitored. The method was validated in the 5-150 µg kg -1 range using total error approach. Thus, performance criteria of the method were evaluated. Relative standard deviations for trueness and precision were lower than 10%; with the exception of hard pressed cheese at 5 µg kg -1 for precision. The limit of quantification (LOQ) was around 5-7 µg kg -1 depending on the matrix of interest. The method was successfully applied to accurately quantify N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in 146 various dairy products with a maximum contamination level of 225 µg kg -1 in cheese. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Quantitative determination and pharmacokinetic study of the novel anti-Parkinson's disease candidate drug FLZ in rat brain by high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Hou, Jinfeng; Qu, Feng; Wu, Caisheng; Ren, Qiang; Zhang, Jinlan

    2012-07-01

    FLZ (N-[2-(4-hydroxy-phenyl)-ethyl]-2-(2,5-dimethoxy-phenyl)-3-(3-methoxy-4-hydroxyphenyl)-acrylamide) is a novel anti-Parkinson's disease candidate drug. A sensitive and specific high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and validated for the quantification of FLZ in rat brain. Carbamazepine was selected as the internal standard. Sample preparation involved double liquid-liquid extraction by n-hexane and ethyl acetate with high extraction efficiency. The chromatographic separation was achieved on a Zorbax SB-C(18) column (100 mm × 2.1 mm, 3.5 μm) with an isocratic elution system comprised of acetonitrile and 0.3% aqueous acetic acid at a flow rate of 0.3 ml/min. The elutes were detected under positive electrospray ionization (ESI) and the target analytes were quantified by multiple reaction monitoring (MRM) mode. The method was sensitive with the lowest limit of quantification (LLOQ) at 1.0 ng/g brain tissue. Good linearity (r>0.99) was obtained over the range of 1.0-400 ng/g. The intra- and inter-day precision ranged from 0.68% to 12%, while the accuracy between 92.7% and 111%. In addition, the stability, recovery and matrix effect involved in this method were also validated. The method was used to investigate the pharmacokinetics of FLZ in rat brain successfully after intravenous administration. The brain distribution studies showed that the brain distribution of FLZ was limited with the penetration ratio less than 0.1 in rats, with no target effect in the seven collected regions. Inhibition of P-glycoprotein (P-gp) by zosuquidar·3HCl ((2R)-1-{4-[(1aR,10bS)-1,1-difluoro-1,1a,6,10b-tetrahydrodibenzo[a,e]cyclopropa[c][7]annulen-6-yl]-1-piperazinyl}-3-(5-quinolinyloxy)-2-propanol trihydrochloride) resulted in a significant increase in brain-to-plasma ratio, while no significant increase by inhibition of breast cancer resistance protein (BCRP) by ko143 (2-methyl-2-propanyl 3-[(3S,6S,12aS)-6-isobutyl-9-methoxy-1,4-dioxo-1,2,3,4,6,7,12,12a-octahydropyrazino[1',2':1,6]pyrido[3,4-b]indol-3-yl]propanoate). The results indicated that FLZ had poor penetration to the brain due to the P-gp transport system. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Simultaneous determination of codeine, ephedrine, guaiphenesin and chlorpheniramine in beagle dog plasma using high performance liquid chromatography coupled with tandem mass spectrometric detection: application to a bioequivalence study.

    PubMed

    Hu, Ziyan; Zou, Qiaogen; Tian, Jixin; Sun, Lili; Zhang, Zunjian

    2011-12-15

    A rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of codeine, ephedrine, guaiphenesin and chlorpheniramine in beagle dog plasma has been developed and validated. Following liquid-liquid extraction, the analytes were separated on a reversed-phase C(18) column (150 mm × 2.0 mm, 3 μm) using formic acid:10 mM ammonium acetate:methanol (0.2:62:38, v/v/v) as mobile phase at a flow rate of 0.2 mL/min and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode. The method was linear for all analytes over the following concentration (ng/mL) ranges: codeine 0.08-16; ephedrine 0.8-160; guaiphenesin 80-16,000; chlorpheniramine 0.2-40. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. It is the first time that the validated HPLC-MS/MS method was successfully applied to a bioequivalence study in 6 healthy beagle dogs. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    PubMed

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma.

    PubMed

    Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang

    2005-03-25

    A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan.

  11. Simultaneous quantification of four metabolites of sulfur mustard in urine samples by ultra-high performance liquid chromatography-tandem mass spectrometry after solid phase extraction.

    PubMed

    Liu, Chang-Cai; Liu, Shi-Lei; Xi, Hai-Ling; Yu, Hui-Lan; Zhou, Shi-Kun; Huang, Gui-Lan; Liang, Long-Hui; Liu, Jing-Quan

    2017-04-07

    Four HD urinary metabolites including hydrolysis metabolite thiodiglycol (TDG), glutathione-derived metabolite 1,1'-sulfonylbis[2-S-(N-acetylcysteinyl)ethane] (SBSNAE), as well as the β-lyase metabolites 1,1'-sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE) and 1-methylsulfinyl-2-[2-(methylthio) ethylsulfonyl]ethane (MSMTESE) are considered as important biomarkers for short-term retrospective detection of HD exposure. In this study, a single method for simultaneous quantification of the four HD metabolites in urine samples was developed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The four urinary metabolites were simultaneously extracted from urinary samples using a solid phase extraction (SPE) method with high extraction recoveries for all four metabolites varied in the range of 71.1-103% followed by UHPLC-MS/MS analysis. The SPE is simple and high effective only requiring 0.1mL of urinary samples and 0.5h time consuming. The problem of previous co-elution of TDG and SBSNAE in UHPLC was well solved, and complete separation of TDG, SBSNAE, SBMSE and MSMTESE from SPE-processed urine matrix was obtained to increase specificity and sensitivity. A full method validation was performed for each analyte in urine matrix. The linear range of calibration curves for the four analytes were respectively from 0.50-500ngmL -1 for TDG and SBSNAE, 0.05-500ngmL -1 for SBMSE and MSMTESE with coefficient of determination value (R 2 ) ≥0.990. The limit of detection was 0.25ngmL -1 for TDG and SBSNAE, 0.01ngmL -1 for SBMSE and MSMTESE spiked in normal urine. The intra/inter-day precision for each analyte at three QC levels had relative standard deviation (%RSD) of ≤10.3%, and the intra/inter-day accuracy ranged between 88.0-108%. This developed method allows for simultaneous and trace measurement of four HD urinary metabolites within one single determination with the lowest usage amount of urine samples over all previous methods This study provides a useful tool for early diagnosis and monitoring of HD poisoning for medical treatment with high confidence, avoiding the need for application of several analysis methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. TRIC: an automated alignment strategy for reproducible protein quantification in targeted proteomics.

    PubMed

    Röst, Hannes L; Liu, Yansheng; D'Agostino, Giuseppe; Zanella, Matteo; Navarro, Pedro; Rosenberger, George; Collins, Ben C; Gillet, Ludovic; Testa, Giuseppe; Malmström, Lars; Aebersold, Ruedi

    2016-09-01

    Next-generation mass spectrometric (MS) techniques such as SWATH-MS have substantially increased the throughput and reproducibility of proteomic analysis, but ensuring consistent quantification of thousands of peptide analytes across multiple liquid chromatography-tandem MS (LC-MS/MS) runs remains a challenging and laborious manual process. To produce highly consistent and quantitatively accurate proteomics data matrices in an automated fashion, we developed TRIC (http://proteomics.ethz.ch/tric/), a software tool that utilizes fragment-ion data to perform cross-run alignment, consistent peak-picking and quantification for high-throughput targeted proteomics. TRIC reduced the identification error compared to a state-of-the-art SWATH-MS analysis without alignment by more than threefold at constant recall while correcting for highly nonlinear chromatographic effects. On a pulsed-SILAC experiment performed on human induced pluripotent stem cells, TRIC was able to automatically align and quantify thousands of light and heavy isotopic peak groups. Thus, TRIC fills a gap in the pipeline for automated analysis of massively parallel targeted proteomics data sets.

  13. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  14. An isotope dilution ultra high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of sugars and humectants in tobacco products.

    PubMed

    Wang, Liqun; Cardenas, Roberto Bravo; Watson, Clifford

    2017-09-08

    CDC's Division of Laboratory Sciences developed and validated a new method for the simultaneous detection and measurement of 11 sugars, alditols and humectants in tobacco products. The method uses isotope dilution ultra high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and has demonstrated high sensitivity, selectivity, throughput and accuracy, with recoveries ranging from 90% to 113%, limits of detection ranging from 0.0002 to 0.0045μg/mL and coefficients of variation (CV%) ranging from 1.4 to 14%. Calibration curves for all analytes were linear with linearity R 2 values greater than 0.995. Quantification of tobacco components is necessary to characterize tobacco product components and their potential effects on consumer appeal, smoke chemistry and toxicology, and to potentially help distinguish tobacco product categories. The researchers analyzed a variety of tobacco products (e.g., cigarettes, little cigars, cigarillos) using the new method and documented differences in the abundance of selected analytes among product categories. Specifically, differences were detected in levels of selected sugars found in little cigars and cigarettes, which could help address appeal potential and have utility when product category is unknown, unclear, or miscategorized. Copyright © 2017. Published by Elsevier B.V.

  15. [Determination of strobilurin fungicides in fruits and their mass fragmentation routes by ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhou, Yao; Yang, Huiqin; Shi, Yiyin; Chen, Jiaxian; Zhu, Jian; Deng, Xiaojun; Guo, Dehua

    2017-09-08

    A method was developed for the simultaneous determination of six strobilurin fungicide ( E -metominostrobin, azoxystrobin, kresoxim-methyl, picoxystrobin, pyraclostrobin and trifloxystrobin) residues in orange, banana, apple and pineapple samples by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The fragmentation routes of all the compounds were explained by the aid of a fragment predicting software ACD Lab/MS Fragmenter. The samples were extracted by acetonitrile, then cleaned up by amino solid phase extraction cartridges (SupelClean LC-NH 2 ). The extracts were separated on a ACQUITY UPLC BEH C 18 column (50 mm×2.1 mm, 1.7 μm) with gradient elution. Acetonitrile containing 0.1% (v/v) formic acid and 10 mmol/L ammonium acetate containing 0.1% (v/v) formic acid were used as mobile phases. The samples were detected by electrospray ionization (ESI)-MS/MS in positive ion and multiple reaction monitoring (MRM) mode, quantified by external standard method. Good linearities were obtained in the range of 5-100 μg/L (for pyraclostrobin, 1-20 μg/L) with correlation coefficients ( r 2 ) greater than 0.999. The recoveries ranged from 60.4% to 120% with the relative standard deviations between 2.15% and 15.1% ( n =6). The developed method can meet the inspection of the six strobilurin residues in the orange, banana, apple and pineapple samples.

  16. [Determination of biurea in flour and its products by liquid chromatography-tandem mass spectrometry].

    PubMed

    Wang, Ya; Wang, Junsu; Xiang, Lu; Xi, Cunxian; Chen, Dongdong; Peng, Tao; Wang, Guomin; Mu, Zhaode

    2014-05-01

    A novel method was established for the determination and identification of biurea in flour and its products using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The biurea was extracted with water and oxidized to azodicarbonamide by potassium permanganate. The azodicarbonamide was then derivatized using sodium p-toluene sulfinate solution. The separation was performed on a Shimpak XR-ODS II column (150 mm x 2.0 mm, 2.2 microm) using the mobile phase composed of acetonitrile and 2 mmol/L ammonium acetate aqueous solution (containing 0.2% (v/v) formic acid) with a gradient elution program. Tandem mass spectrometric detection was performed in multiple reaction monitoring (MRM) scan mode with a positive electrospray ionization (ESI(+)) source. The method used stable isotope internal standard quantitation. The calibration curve showed good linearity over the range of 1-20 000 microg/kg (R2 = 0.999 9). The limit of quantification was 5 microg/kg for biurea spiked in flour and its products. At the spiking levels of 5.0, 10.0 and 50.0 microg/kg in different matrices, the average recovery o biurea was 78.3%-108.0% with the relative standard deviations (RSDs) < or = 5.73%. The method developed is novel, reliable and sensitive with wide linear range, and can be used to determine the biurea in flour and its products.

  17. Multiclass screening method based on solvent extraction and liquid chromatography-tandem mass spectrometry for the determination of antimicrobials and mycotoxins in egg.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Laganà, Aldo

    2012-12-14

    A QuEChERS (Quick Easy Cheap Effective Rugged Safe)-like extraction method was developed for the simultaneous analysis of veterinary drugs and mycotoxins in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray (ESI) source. Various classes of antimicrobials (tetracyclines, ionophores, coccidiostats, penicillins, cephalosporins, fluoroquinolones, sulfonamides) and mycotoxins (enniatins, beauvericin, ochratoxins, aflatoxins) were considered for the development of this method. Particular attention was devoted to extraction optimization: different solvents (acetone, acetonitrile and methanol), different pH values and different sample to extracting volume ratios were tested and evaluated in terms of recovery, relative standard deviation (RSD) and ESI signal suppression due to matrix effect. Chromatographic and mass spectrometric conditions were optimized to obtain the best instrumental performances for most of the analytes. Quantitative analysis was performed by means of matrix-matched calibration, in a range that varied depending on the analyte and its established maximum limit, when there was one. Recoveries at 100 μg kg(-1) spiking level were >62% (3

  18. Comparative study of sugar fermentation and protein expression patterns of two Lactobacillus plantarum strains grown in three different media.

    PubMed

    Plumed-Ferrer, Carme; Koistinen, Kaisa M; Tolonen, Tiina L; Lehesranta, Satu J; Kärenlampi, Sirpa O; Mäkimattila, Elina; Joutsjoki, Vesa; Virtanen, Vesa; von Wright, Atte

    2008-09-01

    A comparative study of two strains of Lactobacillus plantarum (REB1 and MLBPL1) grown in commercial medium (MRS broth), cucumber juice, and liquid pig feed was performed to explore changes to the metabolic pathways of these bacteria, using a proteomics approach (two-dimensional electrophoresis and liquid chromatography-tandem mass spectrometry) combined with analyses of fermentable sugars and fermentation end products. The protein expression showed that even with an excess of glucose in all media, both strains could metabolize different carbohydrates simultaneously and that hexoses could also be used via a phosphoketolase pathway with preferential expression in liquid feed. Sugar analyses showed that the fermentation of sugars was homolactic for all media, with some heterolactic activity in liquid feed, as shown by the production of acetate. Cucumber juice (the medium with the highest glucose content) showed the lowest hexose consumption (10%), followed by liquid feed (33%) and MRS broth (50%). However, bacterial growth was significantly higher in cucumber juice and liquid feed than in MRS broth. This discrepancy was due to the growth benefit obtained from the utilization of the malate present in cucumber juice and liquid feed. Despite different growth conditions, the synthesis of essential cellular components and the stress response of the bacteria were unaffected. This study has improved our understanding of the mechanisms involved in the growth performance of an appropriate lactic acid bacterium strain to be used for food and feed fermentation, information that is of crucial importance to obtain a high-quality fermented product.

  19. [Determination of arbutin in apple juice concentrate by ultra performance liquid chromatography with electrospray ionization tandem mass spectrometry].

    PubMed

    Kong, Xianghong; He, Qiang; Yue, Aishan; Wu, Shuangmin; Li, Jianhua

    2010-06-01

    An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of arbutin in apple juice concentrate. Samples were diluted with water, then cleaned-up with a PS-DVB column. Quantitation was carried out using an external standard method. UPLC was performed on an Eclipse Plus C, column (100 mm x 2.1 mm, 1.8 microm) using a gradient solvent system (methanol-water). MS/MS was performed with multiple reaction monitoring (MRM) mode. The detection limit of arbutin was 0.02 mg/L. The method showed good linear relationship at the range of 0.04-2.0 mg/L. The recoveries ranged from 75.2% to 102.7% with relative standard deviations (RSDs) less than 8.9%. The method is simple, fast and sensitive. It's suitable for quantitative and qualitative analysis of arbutin in apple juice concentrate.

  20. Determination of Phenylalanine and Tyrosine by High Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Peat, Judy; Garg, Uttam

    2016-01-01

    Hyperphenylalaninemia/phenylketonuria (PKU) is one of the most common inborn errors of amino acid metabolism affecting about 1:15,000 infants in the United States. PKU is an autosomal recessive disorder that if untreated results in mental retardation. The most common cause of PKU is deficiency of the enzyme phenylalanine hydroxylase that converts phenylalanine to tyrosine. Tyrosine deficiency results in impaired synthesis of catecholamines and thyroxine. Less commonly, it can result from defects in the synthesis or regeneration of tetrahydrobiopterin (BH4), an essential cofactor for the enzyme phenylalanine hydroxylase. Increased phenylalanine and decreased tyrosine in blood are used in the diagnosis and follow-up of patients with PKU. LC/MS/MS method is described for the quantification of phenylalanine and tyrosine.

  1. Relationship between effort-reward imbalance and hair cortisol concentration in female kindergarten teachers.

    PubMed

    Qi, Xingliang; Zhang, Jing; Liu, Yapeng; Ji, Shuang; Chen, Zheng; Sluiter, Judith K; Deng, Huihua

    2014-04-01

    The present study aims to investigate the relationship between effort-reward imbalance and hair cortisol concentration among teachers to examine whether hair cortisol can be a biomarker of chronic work stress. Hair samples were collected from 39 female teachers from three kindergartens. Cortisol was extracted from the hair samples with methanol, and cortisol concentrations were measured with high performance liquid chromatography-tandem mass spectrometry. Work stress was measured using the effort-reward imbalance scale. The ratio of effort to reward showed significantly positive association with hair cortisol concentration. The cortisol concentration in the system increases with the effort-reward imbalance. Measurement of hair cortisol can become a useful biomarker of chronic work stress. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. [Determination of five synthetic sweeteners in wines using high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Ji, Chao; Feng, Feng; Chen, Zhengxing; Sun, Li; Chu, Xiaogang

    2010-08-01

    A high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS) method for the determination of five synthetic sweeteners (acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame) in wines has been developed. The HPLC separation was carried out on an Ultimate C18 column (100 mm x 2.1 mm, 3 microm). Several parameters, including the composition and pH of the mobile phase, column temperature and the monitor ions, were optimized for improving the chromatographic performance and the sensitivity of determination. The results demonstrated that the separation can be completed in less than 5 min by gradient elution with 20 mmol/L ammonium formate and 0.1% (v/v) formic acid (pH 3.8) and methanol as the mobile phase. The column temperature was kept at 45 degrees C. When the analytes were detected by ESI -MS/MS under multiple reaction monitoring mode, the detection limits were 0.6, 5, 1, 0.8 and 0.2 microg/L for acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame, respectively. The average recoveries ranged from 87.2% to 103%. The relative standard deviations were not more than 1.2%. This method is rapid, accurate, highly sensitive and suitable for the quality control of low concentration of the synthetic sweeteners, which are illegally added to wines and other foods with complex matrices.

  3. A novel ultra high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of xanthones and steroidal saponins in crude and salt-processed Anemarrhenae Rhizoma aqueous extracts.

    PubMed

    Ji, De; Su, Xiaonan; Huang, Ziyan; Wang, Qiaohan; Lu, Tulin

    2018-06-01

    We established a rapid and sensitive ultra high-performance liquid chromatography tandem mass spectrometry method for the simultaneous quantification of xanthones and steroidal saponins in rat plasma. Chromatographic separation was achieved on a C 18 column with a mobile phase comprising acetonitrile and 0.1% formic acid. The detection was performed by negative electrospray ionization in multiple reaction monitoring mode. The validated method showed good linearity within the tested range (r > 0.9945). The intra- and interday precision at high, medium, and low concentrations was less than 7.96%. The bias of accuracies ranged from -1.92 to 9.62%. The extraction recoveries of the compounds ranged from 84.78 to 88.69%, and the matrix effects ranged from 96.76 to 108.59%. This method was successfully applied to a pharmacokinetic comparison of crude and salt-processed Anemarrhenae Rhizoma aqueous extracts after oral administration in rats. The maximum plasma concentration and area under concentration-time curve of timosaponin BIII and timosaponin AIII increased significantly (P < 0.05 or 0.01) and those of timosaponin BII decreased significantly (P < 0.05) after processing. These results could contribute to the clinical application of crude and salt-processed Anemarrhenae Rhizoma and reveal the processing mechanism. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Wipe selection for the analysis of surface materials containing chemical warfare agent nitrogen mustard degradation products by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Willison, Stuart A

    2012-12-28

    Degradation products arising from nitrogen mustard chemical warfare agent were deposited on common urban surfaces and determined via surface wiping, wipe extraction, and liquid chromatography–tandem mass spectrometry detection. Wipes investigated included cotton gauze, glass fiber filter, non-woven polyester fiber and filter paper, and surfaces included several porous (vinyl tile, painted drywall, wood) and mostly non-porous (laminate, galvanized steel, glass) surfaces. Wipe extracts were analyzed by ultra-high pressure liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) and compared with high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) results. An evaluation of both techniques suggests UPLC–MS/MS provides a quick and sensitive analysis of targeted degradation products in addition to being nearly four times faster than a single HPLC run, allowing for greater throughput during a wide-spread release concerning large-scale contamination and subsequent remediation events. Based on the overall performance of all tested wipes, filter paper wipes were selected over other wipes because they did not contain interferences or native species (TEA and DEA) associated with the target analytes, resulting in high percent recoveries and low background levels during sample analysis. Other wipes, including cotton gauze, would require a pre-cleaning step due to the presence of large quantities of native species or interferences of the targeted analytes. Percent recoveries obtained from a laminate surface were 47–99% for all nitrogen mustard degradation products. The resulting detection limits achieved from wipes were 0.2 ng/cm(2) for triethanolamine (TEA), 0.03 ng/cm(2) for N-ethyldiethanolamine (EDEA), 0.1 ng/cm(2) for N-methyldiethanolamine (MDEA), and 0.1 ng/cm(2) for diethanolamine (DEA).

  5. Development and validation of a rapid and simple LC-MS/MS method for quantification of vemurafenib in human plasma: application to a human pharmacokinetic study.

    PubMed

    Bihan, Kevin; Sauzay, Chloé; Goldwirt, Lauriane; Charbonnier-Beaupel, Fanny; Hulot, Jean-Sebastien; Funck-Brentano, Christian; Zahr, Noël

    2015-02-01

    Vemurafenib (Zelboraf) is a new tyrosine kinase inhibitor that selectively targets activated BRAF V600E gene and is indicated for the treatment of advanced BRAF mutation-positive melanoma. We developed a simple method for vemurafenib quantification using liquid chromatography-tandem mass spectrometry. A stability study of vemurafenib in human plasma was also performed. (13)C(6)-vemurafenib was used as the internal standard. A single-step protein precipitation was used for plasma sample preparation. Chromatography was performed on an Acquity UPLC system (Waters) with chromatographic separation by the use of an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7-mm particle size; Waters). Quantification was performed using the monitoring of multiple reactions of following transitions: m/z 488.2 → 381.0 for vemurafenib and m/z 494.2 → 387.0 for internal standard. This method was linear over the range from 1.0 to 100.0 mcg/mL. The lower limit of quantification was 0.1 mcg/mL for vemurafenib in plasma. Vemurafenib remained stable for 1 month at all levels tested, when stored indifferently at room temperature (20 °C), at +4 °C, or at -20 °C. This method was used successfully to perform a plasma pharmacokinetic study of vemurafenib in a patient after oral administration at a steady state. This liquid chromatography-tandem mass spectrometry method for vemurafenib quantification in human plasma is simple, rapid, specific, sensitive, accurate, precise, and reliable.

  6. MEASUREMENT OF OXIDATIVE STRESS PARAMETERS USING LIQUID CHROMATOGRAPHY - TANDEM MASS SPECTROSCOPY (LC-MS/MS)

    EPA Science Inventory

    What is the study?
    An invited review article. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    Why was it done?
    Although oxidative stress is frequently cited as a cause of various adverse biological eff...

  7. Single Laboratory Validated Method for Determination of Microcystins and Nodularin in Ambient Freshwaters by Solid Phase Extraction and Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)

    EPA Pesticide Factsheets

    This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.

  8. An ultra-high pressure liquid chromatography-tandem mass spectrometry method for the quantification of teicoplanin in plasma of neonates.

    PubMed

    Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G

    2017-03-15

    The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Analytical interference of 4-hydroxy-3-methoxymethamphetamine with the measurement of plasma free normetanephrine by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Dunand, Marielle; Donzelli, Massimiliano; Rickli, Anna; Hysek, Cédric M; Liechti, Matthias E; Grouzmann, Eric

    2014-08-01

    The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Quantitation of dityrosine in wheat flour and dough by liquid chromatography-tandem mass spectrometry.

    PubMed

    Hanft, Franziska; Koehler, Peter

    2005-04-06

    A method for the quantitation of dityrosine in wheat flour and dough by high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) using an isotope dilution assay with the internal standard 3,3'-(13)C(2)-dityrosine in the single-reaction monitoring mode was developed. The method consisted of the release of protein-bound dityrosine by hydrolysis in 4 mol/L hydrochloric acid/8.9 mol/L propionic acid for 24 h at 110 degrees C after addition of the internal standard, cleanup by C(18) solid-phase extraction, and HPLC-MS/MS. The limit of detection of dityrosine was 80 ng/g of sample (0.22 nmol/g), and the limit of quantitation was 270 ng/g of sample (0.75 nmol/g). The method was sensitive enough to analyze wheat flour and dough and to study the effect of flour improvers on the dityrosine content. Furthermore, the effect of the mixing time was studied. The dityrosine concentration in the flour was 0.66 nmol/g. After we mixed a dough to peak consistency, the dityrosine concentration doubled and remained constant on further mixing. Overdoses of hydrogen peroxide and hexose oxidase (HOX, E.C. 1.1.3.5) resulted in a strongly increased dityrosine content, whereas no increase of the dityrosine concentration was found after the addition of ascorbic acid and potassium bromate. Calculation of the percentage of dimeric tyrosine showed that less than 0.1% of the tyrosine residues of wheat protein were cross-linked. Therefore, dityrosine residues seem to play only a very minor role in the structure of wheat gluten.

  11. Liquid chromatography-tandem mass spectrometry assay for the quantification of free and total sialic acid in human cerebrospinal fluid.

    PubMed

    van der Ham, Maria; de Koning, Tom J; Lefeber, Dirk; Fleer, André; Prinsen, Berthil H C M T; de Sain-van der Velden, Monique G M

    2010-05-01

    Analysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was validated. The method utilized a simple sample-preparation procedure of protein precipitation for FSA and acid hydrolysis for TSA. Negative electrospray ionisation was used to monitor the transitions m/z 308.2-->87.0 (SA) and m/z 311.2--> 90.0 ((13)C(3)-SA). Conjugated sialic acid (CSA) was calculated by subtracting FSA from TSA. We established reference intervals for FSA, TSA and CSA in CSF in 217 control subjects. The method has been applied to patients' samples with known differences in SA metabolites like meningitis (n=6), brain tumour (n=2), leukaemia (n=5), and Salla disease (n=1). Limit of detection (LOD) was 0.54 microM for FSA and 0.45 mM for TSA. Intra- and inter-assay variation for FSA (21.8 microM) were 4.8% (n=10) and 10.4% (n=40) respectively. Intra- and inter-assay variation for TSA (35.6 microM) were 9.7% (n=10) and 12.8% (n=40) respectively. Tested patients showed values of TSA above established reference value. The validated method allows sensitive and specific measurement of SA metabolites in CSF and can be applied for clinical diagnoses. 2010 Elsevier B.V. All rights reserved.

  12. Analysis of fenretinide and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics.

    PubMed

    Cho, Hwang Eui; Min, H Kang

    2017-01-05

    A simple and accurate high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of N-(4-hydroxyphenyl)retinamide (fenretinide, 4-HPR) and its metabolites, 4-oxo-N-(4-hydroxyphenyl)retinamide (4-oxo-4-HPR) and N-(4-methoxyphenyl)retinamide (4-MPR), in human plasma. Plasma samples were prepared using protein precipitation with ethanol. Chromatographic separation of the three analytes and N-(4-ethoxyphenyl)retinamide (4-EPR), an internal standard, was achieved on a Zorbax SB-C18 column (3.5μm, 50×2.1mm) using gradient elution with the mobile phase of 0.1% formic acid in water and acetonitrile (pH* 2.4) at a flow rate of 0.5mL/min. Electrospray ionization (ESI) mass spectrometry was operated in the positive ion mode with multiple reaction monitoring (MRM). The calibration curves obtained were linear over the concentration range of 0.2-50ng/mL with a lower limit of quantification of 0.2ng/mL. The relative standard deviation of intra-day and inter-day precision was below 7.64%, and the accuracy ranged from 94.92 to 105.43%. The extraction recoveries were found to be higher than 90.39% and no matrix effect was observed. The analytes were stable for the durations of the stability studies. The validated method was successfully applied to the analyses of the pharmacokinetic study for patients treated with 4-HPR in a clinical trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Profiling of kidney vascular endothelial cell plasma membrane proteins by liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Zan; Xu, Bo; Nameta, Masaaki; Zhang, Ying; Magdeldin, Sameh; Yoshida, Yutaka; Yamamoto, Keiko; Fujinaka, Hidehiko; Yaoita, Eishin; Tasaki, Masayuki; Nakagawa, Yuki; Saito, Kazuhide; Takahashi, Kota; Yamamoto, Tadashi

    2013-06-01

    Vascular endothelial cells (VECs) play crucial roles in physiological and pathologic conditions in tissues and organs. Most of these roles are related to VEC plasma membrane proteins. In the kidney, VECs are closely associated with structures and functions; however, plasma membrane proteins in kidney VECs remain to be fully elucidated. Rat kidneys were perfused with cationic colloidal silica nanoparticles (CCSN) to label the VEC plasma membrane. The CCSN-labeled plasma membrane fraction was collected by gradient ultracentrifugation. The VEC plasma membrane or whole-kidney lysate proteins were separated by sodium dodecyl sulfate polyacrylamide gel electrophoresis and digested with trypsin in gels for liquid chromatography-tandem mass spectrometry. Enrichment analysis was then performed. The VEC plasma membrane proteins were purified by the CCSN method with high yield (approximately 20 μg from 1 g of rat kidney). By Mascot search, 582 proteins were identified in the VEC plasma membrane fraction, and 1,205 proteins were identified in the kidney lysate. In addition to 16 VEC marker proteins such as integrin beta-1 and intercellular adhesion molecule-2 (ICAM-2), 8 novel proteins such as Deltex 3-like protein and phosphatidylinositol binding clathrin assembly protein (PICALM) were identified. As expected, many key functions of plasma membranes in general and of endothelial cells in particular (i.e., leukocyte adhesion) were significantly overrepresented in the proteome of CCSN-labeled kidney VEC fraction. The CCSN method is a reliable technique for isolation of VEC plasma membrane from the kidney, and proteomic analysis followed by bioinformatics revealed the characteristics of in vivo VECs in the kidney.

  14. High-performance liquid chromatography-tandem mass spectrometry for simultaneous determination of raltegravir, dolutegravir and elvitegravir concentrations in human plasma and cerebrospinal fluid samples.

    PubMed

    Tsuchiya, Kiyoto; Ohuchi, Mayu; Yamane, Naoe; Aikawa, Hiroaki; Gatanaga, Hiroyuki; Oka, Shinichi; Hamada, Akinobu

    2018-02-01

    A simple sample treatment procedure and sensitive liquid chromatography-tandem mass spectrometry method were developed for the simultaneous quantification of the concentrations of human immunodeficiency virus-1 integrase strand transfer inhibitors - raltegravir, dolutegravir and elvitegravir - in human plasma and cerebrospinal fluid (CSF). Plasma and CSF samples (20 μL each) were deproteinized with acetonitrile. Raltegravir-d 3 was used as the internal standard. Chromatographic separation was achieved on an XBridge C 18 column (50 × 2.1 mm i.d., particle size 3.5 μm) using acetonitrile-water (7:3, v/v) containing 0.1% formic acid as the mobile phase at a flow rate of 0.2 mL/min. The run time was 5 min. Calibration curves for all three drugs were linear in the range 5-1500 ng/mL for plasma and 1-200 ng/mL for CSF. The intra- and inter-day precision and accuracy of all three drugs in plasma were coefficient of variation (CV) <12.9% and 100.0 ± 12.2%, respectively, while those in CSF were CV <12.3% and 100.0 ± 7.9%, respectively. Successful validation under the same LC-MS/MS conditions for both plasma and CSF indicates this analytical method is useful for monitoring the levels of these integrase strand transfer inhibitors in the management of treatment of HIV-1 carriers. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Wipe Sampling Method and Evaluation of Environmental Variables for Assessing Surface Contamination of 10 Antineoplastic Drugs by Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Colombo, Manuel; Jeronimo, Matthew; Astrakianakis, George; Apte, Chirag; Hon, Chun-Yip

    2017-10-01

    This paper describes a novel wipe sampling and high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method capable of simultaneously detecting 10 antineoplastic drugs (5-fluorouracil, oxaliplatin, methotrexate, vindesine, ifosfamide, cyclophosphamide, vincristine, vinblastine, docetaxel, and paclitaxel). The good overall recoveries and sensitivity values of this method along with the comparatively short run time (8 min) allows for its use in routine monitoring in health care facilities. The long-term behavior of the studied drugs on contaminated surfaces and the effect of surface roughness on drug recoveries were studied to gain insights about how these environmental variables influence the detection, cleaning, and occupational exposure of these drugs. Surfaces with higher roughness parameter (Ra) values (rougher) had the lowest recoveries while those with lower Ra (smoother) presented the highest recoveries. Long-term assessments evidence distinctive drug behaviors with oxaliplatin, vindesine, vincristine, and vinblastine being the less persistent drugs (~20% was recovered after 24 h) and docetaxel and paclitaxel the most persistent drugs with recoveries of 40% and 80% after 1 month. This information indicates the importance of collecting ancillary information about drug usage (throughput, timing, cleaning procedures, etc.) to interpret the results in the context of potential exposure. Finally, the method was successfully applied to evaluate trace surface contamination down to the single picogram per square centimeter in multiple work areas within three local health care centers on Vancouver Island, Canada. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  16. Analysis of nifedipine in human plasma and amniotic fluid by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics in hypertensive pregnant women.

    PubMed

    Filgueira, Gabriela Campos de Oliveira; Filgueira, Osmany Alberto Silva; Carvalho, Daniela Miarelli; Marques, Maria Paula; Moisés, Elaine Christine Dantas; Duarte, Geraldo; Lanchote, Vera Lucia; Cavalli, Ricardo Carvalho

    2015-07-01

    Nifedipine is a dihydropyridine calcium channel blocker used for the treatment of hypertension in pregnant women. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of nifedipine in human plasma and amniotic fluid. Separation of nifedipine and nitrendipine (IS) was performed using a LiChroCART(®) RP-Select B column and a mixture of water:acetonitrile:glacial acetic acid (30:70:0.5 v/v) as the mobile phase. Aliquots of 500μL of biological samples were extracted at pH 13 using dichloromethane:n-pentane (3:7 v/v). The validated method was applied to a study of the pharmacokinetics of nifedipine in human plasma and amniotic fluid samples collected up to 12h after administration of the last slow-release nifedipine (20mg/12h) dose to 12 hypertensive pregnant women. The estimated pharmacokinetic parameters of nifedipine showed a mean AUC(0-12) of 250.2ngh/mL, ClT/F of 89.2L/h, Vd/F of 600.0L and t1/2 5.1h. The mean amniotic fluid/plasma concentration ratio was 0.05. The methods proved to be highly sensitive by showing a lower quantification limit of 0.1ng/mL for both matrices. And this study reports for the first time the complete development and validation of the method to quantify nifedipine in amniotic fluid using LC-MS-MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Oxidatively-induced DNA damage and base excision repair in euthymic patients with bipolar disorder.

    PubMed

    Ceylan, Deniz; Tuna, Gamze; Kirkali, Güldal; Tunca, Zeliha; Can, Güneş; Arat, Hidayet Ece; Kant, Melis; Dizdaroglu, Miral; Özerdem, Ayşegül

    2018-05-01

    Oxidatively-induced DNA damage has previously been associated with bipolar disorder. More recently, impairments in DNA repair mechanisms have also been reported. We aimed to investigate oxidatively-induced DNA lesions and expression of DNA glycosylases involved in base excision repair in euthymic patients with bipolar disorder compared to healthy individuals. DNA base lesions including both base and nucleoside modifications were measured using gas chromatography-tandem mass spectrometry and liquid chromatography-tandem mass spectrometry with isotope-dilution in DNA samples isolated from leukocytes of euthymic patients with bipolar disorder (n = 32) and healthy individuals (n = 51). The expression of DNA repair enzymes OGG1 and NEIL1 were measured using quantitative real-time polymerase chain reaction. The levels of malondialdehyde were measured using high performance liquid chromatography. Seven DNA base lesions in DNA of leukocytes of patients and healthy individuals were identified and quantified. Three of them had significantly elevated levels in bipolar patients when compared to healthy individuals. No elevation of lipid peroxidation marker malondialdehyde was observed. The level of OGG1 expression was significantly reduced in bipolar patients compared to healthy individuals, whereas the two groups exhibited similar levels of NEIL1 expression. Our results suggest that oxidatively-induced DNA damage occurs and base excision repair capacity may be decreased in bipolar patients when compared to healthy individuals. Measurement of oxidatively-induced DNA base lesions and the expression of DNA repair enzymes may be of great importance for large scale basic research and clinical studies of bipolar disorder. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. The Powdering Process with a Set of Ceramic Mills for Green Tea Promoted Catechin Extraction and the ROS Inhibition Effect.

    PubMed

    Fujioka, Kouki; Iwamoto, Takeo; Shima, Hidekazu; Tomaru, Keiko; Saito, Hideki; Ohtsuka, Masaki; Yoshidome, Akihiro; Kawamura, Yuri; Manome, Yoshinobu

    2016-04-11

    For serving green tea, there are two prominent methods: steeping the leaf or the powdered leaf (matcha style) in hot water. The purpose of the present study was to reveal chemical and functional differences before and after the powdering process of green tea leaf, since powdered green tea may contribute to expanding the functionality because of the different ingesting style. In this study, we revealed that the powdering process with a ceramic mill and stirring in hot water increased the average extracted concentration of epigallocatechin gallate (EGCG) by more than three times compared with that in leaf tea using high-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass Spectrometry (LC-MS/MS) analyses. Moreover, powdered green tea has a higher inhibition effect of reactive oxygen species (ROS) production in vitro compared with the same amount of leaf tea. Our data suggest that powdered green tea might have a different function from leaf tea due to the higher catechin contents and particles.

  19. Determination of iodinated X-ray contrast media in sewage by solid-phase extraction and liquid chromatography tandem mass spectrometry.

    PubMed

    Echeverría, S; Borrull, F; Fontanals, N; Pocurull, E

    2013-11-15

    A method for the quantitative determination of five iodinated X-ray contrast media (ICMs) in sewage was developed by solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry. A fused-core analytical column was successfully applied for the first time for the separation of ICMs. Oasis HLB was selected from the sorbents tested because of its higher recoveries. The optimized method allowed the determination of the ICMs at low ng/L levels in both influent and effluent sewage, with detection limits of 40 ng/L and 10 ng/L for most compounds in influent and effluent sewage, respectively. The five ICMs studied were determined in all samples analysed, with iopromide being the analyte found at the highest concentration (8.9 µg/L), while iopamidol was the analyte found at lowest concentration (1.3 µg/L) in influent sewage. Effluent sewage did not show a significant decrease in ICM concentrations. © 2013 Elsevier B.V. All rights reserved.

  20. Production and Characterization of a New α-Glucosidase Inhibitory Peptide from Aspergillus oryzae N159-1

    PubMed Central

    Kang, Min-Gu; Yi, Sung-Hun

    2013-01-01

    An α-glucosidase inhibitor was developed from Aspergillus oryzae N159-1, which was screened from traditional fermented Korean foods. The intracellular concentration of the inhibitor reached its highest level when the fungus was cultured in tryptic soy broth medium at 27℃ for five days. The inhibitor was purified using a series of purification steps involving ultrafiltration, Sephadex G-25 gel permeation chromatography, strong cation exchange solid phase extraction, reverse-phase high performance liquid chromatography, and size exclusion chromatography. The final yield of the purification was 1.9%. Results of the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis indicated that the purified α-glucosidase inhibitor was a tri-peptide, Pro-Phe-Pro, with the molecular weight of 360.1 Da. The IC50 value of the peptide against α-glucosidase activity was 3.1 mg/mL. Using Lineweaver-Burk plot analysis, the inhibition pattern indicated that the inhibitor acts as a mixed type inhibitor. PMID:24198670

  1. Methods for Quantitative Creatinine Determination.

    PubMed

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  2. Grain sorghum proteomics: integrated approach toward characterization of endosperm storage proteins in kafirin allelic variants.

    PubMed

    Cremer, Julia E; Bean, Scott R; Tilley, Michael M; Ioerger, Brian P; Ohm, Jae B; Kaufman, Rhett C; Wilson, Jeff D; Innes, David J; Gilding, Edward K; Godwin, Ian D

    2014-10-08

    Grain protein composition determines quality traits, such as value for food, feedstock, and biomaterials uses. The major storage proteins in sorghum are the prolamins, known as kafirins. Located primarily on the periphery of the protein bodies surrounding starch, cysteine-rich β- and γ-kafirins may limit enzymatic access to internally positioned α-kafirins and starch. An integrated approach was used to characterize sorghum with allelic variation at the kafirin loci to determine the effects of this genetic diversity on protein expression. Reversed-phase high performance liquid chromatography and lab-on-a-chip analysis showed reductions in alcohol-soluble protein in β-kafirin null lines. Gel-based separation and liquid chromatography-tandem mass spectrometry identified a range of redox active proteins affecting storage protein biochemistry. Thioredoxin, involved in the processing of proteins at germination, has reported impacts on grain digestibility and was differentially expressed across genotypes. Thus, redox states of endosperm proteins, of which kafirins are a subset, could affect quality traits in addition to the expression of proteins.

  3. Direct analysis of ethylene glycol in human serum on the basis of analyte adduct formation and liquid chromatography-tandem mass spectrometry.

    PubMed

    Dziadosz, Marek

    2018-01-01

    The aim of this work was to develop a fast, cost-effective and time-saving liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method for the analysis of ethylene glycol (EG) in human serum. For these purposes, the formation/fragmentation of an EG adduct ion with sodium and sodium acetate was applied in the positive electrospray mode for signal detection. Adduct identification was performed with appropriate infusion experiments based on analyte solutions prepared in different concentrations. Corresponding analyte adduct ions and adduct ion fragments could be identified both for EG and the deuterated internal standard (EG-D4). Protein precipitation was used as sample preparation. The analysis of the supernatant was performed with a Luna 5μm C18 (2) 100A, 150mm×2mm analytical column and a mobile phase consisting of 95% A (H 2 O/methanol=95/5, v/v) and 5% B (H 2 O/methanol=3/97, v/v), both with 10mmolL -1 ammonium acetate and 0.1% acetic acid. Method linearity was examined in the range of 100-4000μg/mL and the calculated limit of detection/quantification was 35/98μg/mL. However, on the basis of the signal to noise ratio, quantification was recommended at a limit of 300μg/mL. Additionally, the examined precision, accuracy, stability, selectivity and matrix effect demonstrated that the method is a practicable alternative for EG quantification in human serum. In comparison to other methods based on liquid chromatography, the strategy presented made for the first time the EG analysis without analyte derivatisation possible. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Quantification of Bufadienolides in Bryophyllum pinnatum Leaves and Manufactured Products by UHPLC-ESIMS/MS.

    PubMed

    Oufir, Mouhssin; Seiler, Christina; Gerodetti, Manon; Gerber, Julia; Fürer, Karin; Mennet-von Eiff, Monica; Elsas, Siegward-M; Brenneisen, Rudolf; von Mandach, Ursula; Hamburger, Matthias; Potterat, Olivier

    2015-08-01

    A quantitative assay for determination of the main bufadienolides bersaldegenin-1-acetate (1), bersaldegenin-3-acetate (2), bryophyllin A (3), and bersaldegenin-1,3,5-orthoacetate (4) in Bryophyllum pinnatum leaves and manufactured products was developed and validated. The assay involved extraction by pressurised liquid extraction, followed by quantification by ultrahigh performance liquid chromatography-tandem mass spectroscopy. The ultrahigh performance liquid chromatography-tandem mass spectroscopy method was applied to various batches of leaves harvested on several dates from plants grown at two locations (Brazil and Germany). In addition, press juices prepared from plants cultivated in Germany and Brazil were analysed. The total bufadienolide content ranged from 16.28 to 40.50 mg/100 g dry weight in leaves from plants grown in Brazil. The total content of these four bufadienolides was significantly lower in plants cultivated in Germany (3.78-12.49 mg/100 g dry weight, resp.). The total amounts of bufadienolides were 0.091-0.163 mg/100 mL and 0.89-1.16 mg/100 mL in press juices obtained from plants cultivated in Germany and Brazil, respectively. When analysing single leaves from individual plants, the content of bufadienolides was markedly higher in young leaves. For comparative purposes, the content of these bufadienolides was also determined in Bryophyllum daigremontianum and Bryophyllum tubiflorum. Bersaldegenin-1,3,5-orthoacetate (4) was predominant in the leaves of B. daigremontianum and in the stems of B. tubiflorum, while the leaves of B. tubiflorum contained very low amounts of 1-4. Georg Thieme Verlag KG Stuttgart · New York.

  5. Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Lee, Hye Won; Ji, Hye Young; Kim, Hee Hyun; Cho, Hea-Young; Lee, Yong-Bok; Lee, Hye Suk

    2003-11-05

    A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.

  6. Determination of antibacterial agent tilmicosin in pig plasma by LC/MS/MS and its application to pharmacokinetics.

    PubMed

    Li, Bing; Gong, Shi-Yue; Zhou, Xu-Zheng; Yang, Ya-Jun; Li, Jian-Yong; Wei, Xiao-Juan; Cheng, Fu-Sheng; Niu, Jian-Rong; Liu, Xi-Wang; Zhang, Ji-Yu

    2017-03-01

    A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid-liquid extraction. Chromatographic separation was achieved on a C 18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile-water (90:10, v/v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2  = 0.9998). The intra- and inter-day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC-MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability. Copyright © 2016 John Wiley & Sons, Ltd.

  7. A novel liquid chromatography-tandem mass spectrometry method for determination of menadione in human plasma after derivatization with 3-mercaptopropionic acid.

    PubMed

    Liu, Ruijuan; Wang, Mengmeng; Ding, Li

    2014-10-01

    Menadione (VK3), an essential fat-soluble naphthoquinone, takes very important physiological and pathological roles, but its detection and quantification is challenging. Herein, a new method was developed for quantification of VK3 in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after derivatization with 3-mercaptopropionic acid via Michael addition reaction. The derivative had been identified by the mass spectra and the derivatization conditions were optimized by considering different parameters. The method was demonstrated with high sensitivity and a low limit of quantification of 0.03 ng mL(-1) for VK3, which is about 33-fold better than that for the direct analysis of the underivatized compound. The method also had good precision and reproducibility. It was applied in the determination of basal VK3 in human plasma and a clinical pharmacokinetic study of menadiol sodium diphosphate. Furthermore, the method for the quantification of VK3 using LC-MS/MS was reported in this paper for the first time, and it will provide an important strategy for the further research on VK3 and menadione analogs. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Optimization of solid-phase extraction and liquid chromatography-tandem mass spectrometry for simultaneous determination of capilliposide B and its active metabolite in rat urine and feces: Overcoming nonspecific binding.

    PubMed

    Cheng, Zhongzhe; Zhou, Xing; Li, Wenyi; Hu, Bingying; Zhang, Yang; Xu, Yong; Zhang, Lin; Jiang, Hongliang

    2016-11-30

    Capilliposide B, a novel oleanane triterpenoid saponin isolated from Lysimachia capillipes Hemsl, showed significant anti-tumor activities in recent studies. To characterize the excretion of Capilliposide B, a reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of Capilliposide B and its active metabolite, Capilliposide A in rat urine and feces. Sample preparation using a solid-phase extraction procedure was optimized by acidification of samples at various degrees, providing extensive sample clean-up with a high extraction recovery. In addition, rat urinary samples were pretreated with CHAPS, an anti-adsorptive agent, for overcoming nonspecific analytes adsorption during sample storage and process. The method validation was conducted over the curve range of 10.0-5000ng/ml for both analytes. The intra- and inter-day precision and accuracy of the QC samples showed ≤11.0% RSD and -10.4-12.8% relative error. The method was successfully applied to an excretion study of Capilliposide B following intravenous administration. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of limonin in dog plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.

    PubMed

    Liu, Shi-jia; Zhou, Ling; Zhang, Jun; Yu, Bo-yang; Li, Chang-yin; Liu, Zi-xiu; Ju, Wen-zheng

    2013-04-01

    A highly sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of limonin in beagle dog plasma using nimodipine as internal standard. The analyte and internal standard (IS) were extracted with ether followed by a rapid isocratic elution with 10 mm ammonium acetate buffer-methanol (26:74, v/v) on a C18 column (150 × 2.1 mm i.d.) and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 469.4 → 229.3 and m/z 417.2 → 122.0 were used to measure the analyte and the IS. The assay was linear over the concentration range of 0.625-100 ng/mL for limonin in dog plasma. The lower limit of quantification was 0.312 ng/mL and the extraction recovery was >90.4% for limonin. The inter- and intra-day precision of the method at three concentrations was less than 9.9%. The method was successfully applied to pharmacokinetic study of limonin in dogs. Copyright © 2012 John Wiley & Sons, Ltd.

  10. An ultra-pressure liquid chromatography-tandem mass spectrometry method for the simultaneous determination of three physalins in rat plasma and its application to pharmacokinetic study of Physalis alkekengi var. franchetii (Chinese lantern) in rats.

    PubMed

    Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang

    2012-01-25

    An ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantification of three major ingredients in Chinese lantern preparations (CLP) in rat plasma. Following extraction by ethyl acetate, the analytes were separated on an Acquity UPLC BEH Shield RP C(18) column using a gradient mobile phase system of acetonitrile-water. Electrospray ionization (ESI) tandem interface was employed prior to mass spectrometric detection. The calibration curves were linear over the range of 5.0-500.0 ng/ml for physalin D, 2.3-230.0 ng/ml for physalin G and 0.71-71.0 ng/ml for 4,7-didehydroneophysalin B. The average extraction recoveries, examined at four concentration levels, carried from 57.1% to 76.9%, and the accuracies ranged from 94.0% to 113.3% with precision (RSD) <15%. The validated method was successfully applied to the determination of the three physalins in rat plasma after intragastric administration of CLP suspension. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Determination of a PDE4 inhibitor Hemay005 in human plasma and urine by UPLC-MS/MS and its application to a PK study.

    PubMed

    Liu, Xuemei; Chen, Rui; Zeng, Guanghuai; Gao, Ying; Liu, Xiuping; Zhang, Donglei; Hu, Pei; Wang, Hongyun; Jiang, Ji

    2018-06-04

    Hemay005 is a novel small-molecule inhibitor of phosphodiesterase-4 developed for the treatment of psoriasis. Measurement of Hemay005 in biological samples is critical for evaluation of its pharmacokinetics in clinical studies. Methodology & results: Plasma and urine samples were extracted and then chromatographed on an Acquity UPLC HSS T3 column with a gradient elution. Detection was performed on a Xevo TQ-S tandem mass spectrometer using negative ESI. For the first time, a sensitive and robust ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established and validated for the quantitative determination of Hemay005 in human plasma and urine, and it was successfully applied to evaluate the pharmacokinetics of Hemay005 in healthy subjects in a first-in-human study.

  12. Multi-residue determination of 210 drugs in pork by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Yin, Zhiqiang; Chai, Tingting; Mu, Pengqian; Xu, Nana; Song, Yue; Wang, Xinlu; Jia, Qi; Qiu, Jing

    2016-09-09

    This paper presents a multi-residue analytical method for 210 drugs in pork using ultra-high-performance liquid chromatography-Q-Trap tandem mass spectrometry (UPLC-MS/MS) within 20min via positive ESI in scheduled multi-reaction monitoring (MRM) mode. The 210 drugs, belonging to 21 different chemical classes, included macrolides, sulfonamides, tetracyclines, β-lactams, β-agonists, aminoglycosides, antiviral drugs, glycosides, phenothiazine, protein anabolic hormones, non-steroidal anti-inflammatory drugs (NSAIDs), quinolones, antifungal drugs, corticosteroids, imidazoles, piperidines, piperazidines, insecticides, amides, alkaloids and others. A rapid and simple preparation method was applied to process the animal tissues, including solvent extraction with an acetonitrile/water mixture (80/20, v/v), defatting and clean-up processes. The recoveries ranged from 52% to 130% with relative standard deviations (RSDs)<20% for spiked concentrations of 10, 50 and 250μg/kg. More than 90% of the analytes achieved low limits of quantification (LOQs)<10μg/kg. The decision limit (CCα), detection capability (CCβ) values were in the range of 2-502μg/kg and 4-505μg/kg, respectively. This method is significant for food safety monitoring and controlling veterinary drug use. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Simultaneous high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) analysis of cyanide and thiocyanate from swine plasma.

    PubMed

    Bhandari, Raj K; Manandhar, Erica; Oda, Robert P; Rockwood, Gary A; Logue, Brian A

    2014-01-01

    An analytical procedure for the simultaneous determination of cyanide and thiocyanate in swine plasma was developed and validated. Cyanide and thiocyanate were simultaneously analyzed by high-performance liquid chromatography tandem mass spectrometry in negative ionization mode after rapid and simple sample preparation. Isotopically labeled internal standards, Na(13)C(15)N and NaS(13)C(15)N, were mixed with swine plasma (spiked and nonspiked), proteins were precipitated with acetone, the samples were centrifuged, and the supernatant was removed and dried. The dried samples were reconstituted in 10 mM ammonium formate. Cyanide was reacted with naphthalene-2,3-dicarboxaldehyde and taurine to form N-substituted 1-cyano[f]benzoisoindole, while thiocyanate was chemically modified with monobromobimane to form an SCN-bimane product. The method produced dynamic ranges of 0.1-50 and 0.2-50 μM for cyanide and thiocyanate, respectively, with limits of detection of 10 nM for cyanide and 50 nM for thiocyanate. For quality control standards, the precision, as measured by percent relative standard deviation, was below 8 %, and the accuracy was within ±10 % of the nominal concentration. Following validation, the analytical procedure successfully detected cyanide and thiocyanate simultaneously from the plasma of cyanide-exposed swine.

  14. Investigation of the biotransformation of osthole by liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Jie; Chan, Wan

    2013-02-23

    Osthole is an active ingredient and one of the major coumarin compounds that were identified in the genus Cnidium moonnieri (L.) Cussion, the fruit of which was used as traditional Chinese medicine to treat male impotence, ringworm infection and blood stasis conventionally. Recent studies revealed that osthole has diverse pharmacological effects, such as improving male sexual dysfunction, anti-diabetes, and anti-hypertentions. The inhibition of thrombosis and platelet aggregation and protection of central nerve were also observed. On the other hand, the metabolism of osthole has not yet been investigated thoroughly. Herein the biotransformation of osthole in rat was investigated after oral administration of osthole by using efficient and sensitive ultra-performance liquid chromatography-tandem quadrupole-time of flight mass spectrometry (UPLC-QTOF/MS). Eighteen osthole metabolites and the parent drug were detected and identified in rat urine. Fourteen metabolites of osthole were identified and characterized for the first time. Structures of metabolites of osthole were elucidated by comparing fragment pattern under MS/MS scan and change of molecular weight with those of osthole. The main phase I metabolic pathways were summed as 7-demethylation, 8-dehydrogenation, hydroxylation on coumarin and 3,4-epoxide. Sulfate conjugates were detected as phase II metabolites of osthole. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Multi-detection of preservatives in cheeses by liquid chromatography-tandem mass spectrometry.

    PubMed

    Fuselli, Fabio; Guarino, Chiara; La Mantia, Alessandro; Longo, Lucia; Faberi, Angelo; Marianella, Rosa Maria

    2012-10-01

    The incorrect use of preservatives in cheeses may compromise food safety and damage consumers. According to the law, more than one preservative may be contemporarily used in cheeses. So a method for their contemporary detection may be useful for both manufacturers and control agencies quality control. In this research a liquid chromatography-tandem mass spectrometric with electrospray ionization method for the multi-determination of seven preservatives (benzoic acid, citric acid, hexamethylenetetramine, lysozyme, natamycin, nisin and sorbic acid) in cheese was developed. The preservatives were contemporarily extracted from cheese by a single procedure, and analyzed by RP-LC/ESI-MS/MS (Ion Trap) in positive ionization mode, with single reaction monitoring (SRM) acquisition. Three sample types (hard, pasta filata and fresh cheese) were used for method evaluation. Recoveries were mostly higher than 90%; MDLs ranged from 0.02 to 0.26 mgkg(-1), and MQLs were included between 0.07 and 0.88 mgkg(-1). Due to matrix effect, quantitation was performed by referring to a matrix matched calibration curve, for each cheese typology. This method was also applied to commercial cheese samples, with good results. It appears fast, reliable and suitable for both screening and confirmation of the presence and quantitation of the preservatives in a single, multi-detection analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17beta-OH steroids.

    PubMed

    Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero

    2006-01-01

    Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.

  17. Simultaneous determination of febuxostat and its three active metabolites in human plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study in Chinese healthy volunteers.

    PubMed

    Wu, Yingli; Mao, Zhengsheng; Liu, Youping; Wang, Xin; Di, Xin

    2015-10-10

    A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of febuxostat and its three active metabolites in human plasma was developed using a ZORBAX SB-C18 column (50 mm × 4.6 mm, 5 μm) and an optimized gradient mobile phase consisting of acetonitrile, water and formic acid. Plasma samples were spiked with the internal standard losartan and then pre-treated using one-step protein precipitation with methanol. Mass spectrometric detection was performed by selective reaction monitoring mode via electrospray ionization source operating in positive ionization mode. The method exhibited good linearity over the concentration range of 10-20,000 ng/mL for febuxostat, 1.0-270 ng/mL for 67M-1 and 67M-2, and 0.8-250 ng/mL for 67 M-4, respectively. The intra- and inter-day precisions were less than 14.7% and the accuracy ranged from -4.3% to 5.1%. The method was successfully applied to a clinical pharmacokinetic study of febuxostat in humans after oral administration of a single dose of febuxostat at 40, 80 and 120 mg. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Residue level and dissipation pattern of lepimectin in shallots using high-performance liquid chromatography coupled with photodiode array detection.

    PubMed

    Kim, Sung-Woo; Rahman, Md Musfiqur; Abd El-Aty, A M; Truong, Lieu T B; Choi, Jeong-Heui; Park, Joon-Seong; Kim, Mi-Ra; Shin, Ho-Chul; Shim, Jae-Han

    2016-11-01

    Lepimectin, as an emulsifiable concentrate, was sprayed on shallots at the recommended dose rate (10 mL/20 L) to determine its residue levels, dissipation pattern, pre-harvest residue limits (PHRLs), and health risk. Samples were randomly collected over 10 days, extracted with acetonitrile, purified using an amino solid-phase extraction (NH 2 -SPE) cartridge and analyzed using a high-performance liquid chromatography-photodiode array detection method. Field-incurred samples were confirmed using ultra-performance liquid chromatography-tandem mass spectrometry. The linearity was excellent, with a determination coefficient (R 2 ) of ≥0.9991. The recoveries at two spiking levels (0.2 and 1.0 mg/kg) ranged from 84.49 to 87.64% with relative standard deviations of ≤7.04%. The developed method was applied to field samples grown in separate greenhouses, one located in Naju and one in Muan, in the Republic of Korea. The dissipation pattern was described by first-order kinetics with half-lives of 1.9 (Naju) and 1.7 days (Muan). The PHRL curves indicated that, if the lepimectin residues are <0.18 (Naju) and <0.13 mg/kg (Muan) 5 days before harvest, the residue levels will be lower than the maximum residue limit (0.05 mg/kg) upon harvesting. The risk assessment data indicated that lepimectin is safe for use in the cultivation of shallots, with no risk of detrimental effects to the consumer. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Monitoring salivary melatonin concentrations in children with sleep disorders using liquid chromatography-tandem mass spectrometry.

    PubMed

    Khan, Sohil A; George, Rani; Charles, Bruce G; Taylor, Paul J; Heussler, Helen S; Cooper, David M; McGuire, Treasure M; Pache, David; Norris, Ross L G

    2013-06-01

    Melatonin is synthesized in the pineal gland and is an important circadian phase marker, especially in the determination of sleep patterns. Both temporary and permanent abnormal sleep patterns occur in children; therefore, it is desirable to have methods for monitoring melatonin in biological fluids in the diagnosis and treatment of such disorders. The objective of the study is to develop a liquid chromatography-tandem mass spectrometry method for the determination of melatonin in saliva and to apply it to monitoring salivary concentrations in children with sleep disorders. A deuterated internal standard (d7-melatonin) was added to a diluted saliva sample (20 µL) in an autosampler vial insert, and 50 µL were injected. Plasticware was strictly avoided, and all glassware was scrupulously cleaned and then baked at 120°C for at least 48 hours to obtain satisfactory performance. Reverse-phase chromatography was performed on a C8 column using a linear gradient elution profile comprising mobile phases A (0.1% aqueous formic acid) and B (15% methanol in acetonitrile containing 0.1% formic acid), pumped at a total flow rate of 0.8 mL/min. The run time was 8 minutes. After atmospheric pressure chemical ionization, mass spectrometric detection was in positive ion mode. Mass detection was by selected reaction monitoring mode with the following mass transitions used for quantification: melatonin, m/z 233.0 → 173.8 and d7-melatonin, m/z 240.0 → 178.3. Linearity (r > 0.999) was established from 3.9 to 1000 pg/mL. Imprecision (coefficient of variation percent) was less than 11%, and accuracy was 100-105% (7.0-900 pg/mL). The method was selective, and the mean (range) ratio of the slopes of calibrations in water to those in daytime saliva samples collected from 10 healthy adult subjects was 0.989 (0.982-0.997), indicating negligible matrix effects. The application of the assay was demonstrated in healthy adults and in children being clinically investigated for sleep disturbances. A validated liquid chromatography-tandem mass spectrometry method suitable for monitoring salivary melatonin in children with circadian rhythm sleep disorders is reported. The method also has potential application to pediatric population pharmacokinetic studies using sparse sampling of saliva as the biological sample matrix.

  20. Determination of perfluorocompounds in popcorn packaging by pressurised liquid extraction and ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Martínez-Moral, María Pilar; Tena, María Teresa

    2012-11-15

    The development and characterisation of a method based on reverse-phase ultra-performance liquid chromatography (UPLC) coupled to a quadrupole-time of flight mass spectrometer (Q-TOF-MS) with negative electrospray ionisation (ESI) to determine perfluorinated compounds (PFCs) in packaging is presented in this paper. Analytes were quantitatively recovered from packaging with methanol in only one PLE cycle of 6 min at 100 °C. The UPLC allowed the successful separation of the studied PFCs in less than 4 min. The whole method presented good precision, with RSDs below 8%, LODs from 0.6 to 16 ng g(-1); and excellent recovery values, around 100% in all cases, were achieved. The PLE-UPLC-MS method was applied to the analysis of popcorn packaging for microwave cooking. Besides the most commonly studied PFCs: PFOA and PFOS, the presence of other perfluorocarboxylic acids (PFCAs) in popcorn packaging is evidenced in this work. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Ultra-performance liquid chromatography-tandem mass spectrometry-based multiplex enzyme assay for six enzymes associated with hereditary hemolytic anemia.

    PubMed

    Park, Chul Min; Lee, Kyunghoon; Jun, Sun-Hee; Song, Sang Hoon; Song, Junghan

    2017-08-15

    Deficiencies in erythrocyte metabolic enzymes are associated with hereditary hemolytic anemia. Here, we report the development of a novel multiplex enzyme assay for six major enzymes, namely glucose-6-phosphate dehydrogenase, pyruvate kinase, pyrimidine 5'-nucleotidase, hexokinase, triosephosphate isomerase, and adenosine deaminase, deficiencies in which are implicated in erythrocyte enzymopathies. To overcome the drawbacks of traditional spectrophotometric enzyme assays, the present assay was based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The products of the six enzymes were directly measured by using ion pairing UPLC-MS/MS, and the precision, linearity, ion suppression, optimal sample amounts, and incubation times were evaluated. Eighty-three normal individuals and 13 patients with suspected enzymopathy were analyzed. The UPLC running time was within 5min. No ion suppression was observed at the retention time for the products or internal standards. We selected an optimal dilution factor and incubation time for each enzyme system. The intra- and inter-assay imprecision values (CVs) were 2.5-12.1% and 2.9-14.3%, respectively. The linearity of each system was good, with R 2 values >0.97. Patient samples showed consistently lower enzyme activities than those from normal individuals. The present ion paring UPLC-MS/MS assay enables facile and reproducible multiplex evaluation of the activity of enzymes implicated in enzymopathy-associated hemolytic anemia. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Hydrophilic interaction liquid chromatography-solid phase extraction directly combined with protein precipitation for the determination of triptorelin in plasma.

    PubMed

    Wang, Jixia; Kong, Song; Yan, Jingyu; Jin, Gaowa; Guo, Zhimou; Shen, Aijin; Xu, Junyan; Zhang, Xiuli; Zou, Lijuan; Liang, Xinmiao

    2014-06-01

    Peptide drugs play a critical role in therapeutic treatment. However, as the complexity of plasma, determination of peptide drugs using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a daunting task. To solve this problem, hydrophilic interaction liquid chromatography-solid phase extraction (HILIC-SPE) directly combined with protein precipitation (PPT) was developed for the selective extraction of triptorelin from plasma. The extracts were analyzed by reversed-phase liquid chromatography (RPLC). Proteins, phospholipids and highly polar interferences could be removed from plasma by the efficient combination of PPT, HILIC-SPE and RPLC-MS/MS. This method was evaluated by matrix effect, recovery and process efficiency at different concentration levels (50, 500 and 5,000 ng/mL) of triptorelin. Furthermore, the performance of HILIC-SPE was compared with that of reversed-phase C18 SPE and hydrophilic lipophilic balance (Oasis HLB) SPE. Among them, HILIC-SPE provided the minimum matrix effect (ranging from 96.02% to 103.41%), the maximum recovery (ranging from 80.68% to 90.54%) and the satisfactory process efficiency (ranging from 82.83% to 92.95%). The validated method was successfully applied to determine triptorelin in rat plasma. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Development of Extraction Methods for the Analysis of Perfluorinated Compounds in Leather with High Performance Liquid Chromatography Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Wang, Youchao; Tang, Chuanjiang; Nie, Jingmei; Xu, Chengtao

    2018-01-01

    Perfluorinated compounds (PFCs), used to provide water, oil, grease, heat and stain repellency to a range of textile and other products, have been found to be persistent in the environment and are associated with adverse effects on humans and wildlife. This study presents the development and validation of an analytical method to determine the simultaneous presence of eleven PFCs in leather using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The perfluorinated compounds were primarily extracted from the samples by a liquid extraction procedure by ultrasonic, in which the parameters were optimized. Then the solid-phase extraction (SPE) is the most important advantages of the developed methodology. The sample volume and elution conditions were optimized by means of an experimental design. The proposed method was applied to determine the PFCs in leather, where the detection limits of the eleven compounds were 0.09-0.96 ng/L, and the recoveries of all compounds spiked at 5 ng/L concentration level were in the range of 65-96%, with a better RSD lower than 19% (n = 7).

  4. Sensitive and rapid determination of pyrethroids in human blood by gas chromatography-tandem mass spectrometry with ultrasound-assisted dispersive liquid-liquid microextraction.

    PubMed

    Gao, Xue; Guo, Hao; Wang, Junwei; Zhao, Qingbiao

    2018-01-19

    In this study, a sensitive and fast procedure of ultrasonic-assisted dispersive liquid-liquid microextraction (UADLLME) coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS) for the determination of major pyrethroid pesticides (permethrin, tetramethrin, bifenthrin, fenvalerate, flucythrinate, fluvalinate, fenpropathrin, deltamethrin, and cyhalothrin) in blood samples was developed. Response surface methodology (RSM) combined with Box-Behnken design (BBD) and ANOVA function was used to optimize key factors affecting the extraction efficiency of UADLLME procedure. Target compounds were analyzed by GC-MS/MS. Under the optimal conditions, good linearity (R 2 >0.99) was achieved for all the analytes in the concentration range of 0.5 to 100 μg L -1 . The recoveries for spiked samples at 3 concentration levels were between 70.2 and 91.8%, with relative standard deviations (RSD) lower than 10%. Very low limits of detection (LODs) and limits of quantification (LOQs) ranging from 0.01 to 0.1 μg L -1 and from 0.03 to 0.3 μg L -1 were achieved. This method was successfully applied to the determination of low concentration of pyrethroids in blood samples from real forensic cases. High sensitivity, fast determination, simplicity in operation, small sample volume, and low usage of organic solvents are the advantages of this method. This methodology is of important value for sensitive and quick determination of residue pesticides and metabolites, study of residue pesticides behavior in human body, as well as application in real forensic cases. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Rapid and sensitive determination of benzo[a]pyrene in black ginseng using fluorescence detector and high performance liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Cho, Hyun-jeong; Kim, Hye-jin; Son, Byeong-cheol; Jo, Dong-keun; Cho, Byung-lim

    2013-05-01

    Black ginseng is produced by steaming a ginseng root followed by drying repeatedly 9 times during the process and it is changed to be black color, so it is known that a black ginseng has more contents of saponins than red ginseng. However a fake black ginseng which is produced to be black color at high temperature in a short period of time generate carcinogenic benzo[a]pyrene(BaP) through the process. In this year, maximum residue level(MRL) for BaP was established to 2 ug/kg in black ginseng and more sensitive method was developed to quantitatively analyze the BaP by high performance liquid chromatography (HPLC) coupling with florescence detector and tandem mass spectrometry (atmospheric pressure chemical ionization-MS/MS). Chromatographic separation was performed on a Supelcosil™ LC-PAH column (3 μm, 3 mm x 50 mm). Mobile phase A was water and mobile phase B was acetonitrile. BaP was exactly separated from other 15 polycyclic aromatic hydrocarbons (PAHs) which have been selected as priority pollutants by the US Environmental Protection Agency (EPA). Linearity of detection was in the range of 0.2~20 μg/kg and limit of detection (LOD) for BaP was lower than 0.1 μg/kg, limit of quantification (LOQ) was 0.2 μg/kg. The recovery of Bap was 92.54%+/-6.3% in black ginseng.

  6. Measurement of thyroxine and its glucuronide in municipal wastewater and solids using weak anion exchange solid phase extraction and ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Brown, Alistair K; Wong, Charles S

    2017-11-24

    A solids extraction method, using sonication in combination with weak anion exchange solid phase extraction, was created to extract thyroxine (T4) and thyroxine-O-β-d-glucuronide (T4-Glc) simultaneously from wastewaters and sludges, and to quantify these compounds via reversed-phase ultra-high performance liquid chromatography-tandem mass spectrometry. The method limits of quantification were all in the low ng/g (dry weight solids) range for both T4 and T4-Glc: 2.13 and 2.63ng/g respectively in primary wastewater, 4.3 and 28.3ng/g for primary suspended solids, for 1.1 and 3.7ng/g for return activated sludge. Precision for measurements of T4 and T4-Glc were 2.6 and 6.5% (intraday) and 9.6 and 5.7% (interday) respectively, while linearity was 0.9967 and 0.9943 respectively. Overall recoveries for T4 and T4-Glc in primary suspended solids were 94% and 95%, and 86 and 101% in primary wastewater, respectively. Extraction efficiency tests using primary sludge determined that one methanol aliquot was sufficient during the extraction process as opposed to 2 or 3 aliquots. Mass loadings at the North Main Wastewater Treatment Plant in Winnipeg, Canada showed 316%, 714%, and 714% greater T4-Glc than T4 associated with the suspended solids of the primary, secondary, and final effluent respectively, yet 765% more T4 than T4-Glc associated with the solids of the mixed liquor. Moreover, 26% of T4 and 49% of T4-Glc were associated with the suspended solids during the treatment process. This method demonstrates the need to assess accurately both metabolite conjugates of contaminants of emerging concern, as well as the sorbed levels of particle-reactive analytes such as T4 in the aquatic environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. [Determination of aniline in water and fish by liquid chromatography-tandem mass spectrometry].

    PubMed

    He, Dechun; Zhao, Bo; Tang, Caiming; Xu, Zhencheng; Zhang, Sukun; Han, Jinglei

    2014-09-01

    A fast analytical method for the determination of aniline in water and fish meat by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. The water sample was mixed with acetonitrile by 4:1 (v/v) and the fish sample was extracted by 2.00 mL acetonitrile for each gram of sample, and then the extracts of water and fish samples were centrifuged at 5,000 r/min for 5 min. The separation was performed on a reversed-phase C18 column using mobile phases of acetonitrile-0.5% (v/v) formic acid aqueous solution (85:15, v/v). Aniline was separated within 3 min. The calibration curve was linear in the range of 0.5-500 pg/L with R2 > 0.999. The limits of detection (LODs) were 0.50 μg/L and 1.00 μg/kg and the limits of quantification (LOQs) were 1.00 μg/L and 2.00 μg/kg for aniline in water and fish meat, respectively. The average recoveries of aniline in water were 93.7% at the spiked level of 40 ng and 86.7% at the spiked level of 400 ng (n = 5). The average recoveries of aniline in fish were 96.8%, 92.6% and 81.8% at the spiked levels of 5, 50 and 500 ng respectively (n = 5). The relative standard deviations were 1.5%-9.2%. Thirteen water samples and twelve fish samples were collected from a reservoir polluted by aniline and the maximum contents found were 1,943. 6 μg/L in water and 60.8 μg/kg in fish. The method is suitable for the determination of aniline residues in water and fish with the characteristics of easy operation, high accuracy and precision.

  8. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    La'ulu, Sonia L; Rasmussen, Kyle J; Straseski, Joely A

    2016-03-05

    Thyroid hormone concentrations fluctuate during growth and development. To accurately diagnose thyroid disease in pediatric patients, reference intervals (RIs) should be established with appropriate age groups from an adequate number of healthy subjects using the most exact methods possible. Obtaining statistically useful numbers of healthy patients is particularly challenging for pediatric populations. The objective of this study was to determine non-parametric RIs for free thyroxine (fT4) and free triiodothyronine (fT3) using equilibrium dialysis-high performance liquid chromatography-tandem mass spectrometry with over 2200 healthy children 6 months-17 years of age. Subjects were negative for both thyroglobulin and thyroid peroxidase autoantibodies and had normal thyrotropin concentrations. The study included 2213 children (1129 boys and 1084 girls), with at least 120 subjects (average of 125) from each year of life, except for the 6 month to 1 year age group (n=96). Non-parametric RIs (95th percentile) for fT4 were: 18.0-34.7 pmol/L (boys and girls, 6 months-6 years) and 14.2-25.7 pmol/L (boys and girls, 7-17 years). RIs for fT3 were: 5.8-13.1 pmol/L (girls, 6 months-6 years); 5.7-11.8 pmol/L (boys, 6 months-6 years); 5.7-10.0 pmol/L (boys and girls, 7-12 years); 4.5-8.6 pmol/L (girls, 13-17 years); and 5.2-9.4 pmol/L (boys, 13-17 years). Numerous significant differences were observed between pediatric age groups and previously established adult ranges. This emphasizes the need for well-characterized RIs for thyroid hormones in the pediatric population.

  9. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    La’ulu, Sonia L.; Rasmussen, Kyle J.; Straseski, Joely A.

    2016-01-01

    Objective: Thyroid hormone concentrations fluctuate during growth and development. To accurately diagnose thyroid disease in pediatric patients, reference intervals (RIs) should be established with appropriate age groups from an adequate number of healthy subjects using the most exact methods possible. Obtaining statistically useful numbers of healthy patients is particularly challenging for pediatric populations. The objective of this study was to determine non-parametric RIs for free thyroxine (fT4) and free triiodothyronine (fT3) using equilibrium dialysis-high performance liquid chromatography-tandem mass spectrometry with over 2200 healthy children 6 months-17 years of age. Methods: Subjects were negative for both thyroglobulin and thyroid peroxidase autoantibodies and had normal thyrotropin concentrations. The study included 2213 children (1129 boys and 1084 girls), with at least 120 subjects (average of 125) from each year of life, except for the 6 month to 1 year age group (n=96). Results: Non-parametric RIs (95th percentile) for fT4 were: 18.0-34.7 pmol/L (boys and girls, 6 months-6 years) and 14.2-25.7 pmol/L (boys and girls, 7-17 years). RIs for fT3 were: 5.8-13.1 pmol/L (girls, 6 months-6 years); 5.7-11.8 pmol/L (boys, 6 months-6 years); 5.7-10.0 pmol/L (boys and girls, 7-12 years); 4.5-8.6 pmol/L (girls, 13-17 years); and 5.2-9.4 pmol/L (boys, 13-17 years). Conclusion: Numerous significant differences were observed between pediatric age groups and previously established adult ranges. This emphasizes the need for well-characterized RIs for thyroid hormones in the pediatric population. PMID:26758817

  10. Development and comparison of HPLC-MS/MS and UPLC-MS/MS methods for determining eight coccidiostats in beef.

    PubMed

    Zhao, Xia; Wang, Bo; Xie, Kaizhou; Liu, Jianyu; Zhang, Yangyang; Wang, Yajuan; Guo, Yawen; Zhang, Genxi; Dai, Guojun; Wang, Jinyu

    2018-06-15

    A high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method and an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining eight coccidiostat (halofuginone, lasalocid, maduramicin, monensin, narasin, nigericin, robenidine and salinomycin) residues in beef were developed and compared. Samples were extracted with a mixture of acetic acid, acetonitrile and ethyl acetate and were then purified on a C 18 solid-phase extraction (SPE) column. The purified samples were analyzed by HPLC-MS/MS and UPLC-MS/MS, using 0.1% formic acid-water solution (A) and pure methanol (B) as the mobile phase. The samples were fractionated on a C 18 column using different gradient elution procedures, followed by qualitative analysis using a mass spectrometer operated in multiple reaction monitoring (MRM) mode with positive electrospray ionization; the external standard method was used for quantitation. At spiked levels that ranged from the limit of quantification (LOQ) to 100 μg/kg, the average recoveries were 71.96%-100.32% and 71.24%-89.24%, with relative standard deviations (RSDs) of 2.65%-12.38% and 2.98%-14.86% for UPLC-MS/MS and HPLC-MS/MS, respectively. The limits of detection (LODs) and LOQs of the eight coccidiostats were 0.14-0.32 μg/kg and 0.43-1.21 μg/kg, respectively, for UPLC-MS/MS analysis and 0.16-0.58 μg/kg and 0.53-1.92 μg/kg, respectively, for HPLC-MS/MS analysis. Both methods had good accuracy and precision, but UPLC-MS/MS had higher sensitivity than HPLC-MS/MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Liquid chromatography-tandem mass spectrometry method for the measurement of serum mevalonic acid: a novel marker of hydroxymethylglutaryl coenzyme A reductase inhibition by statins.

    PubMed

    Waldron, Jenna; Webster, Craig

    2011-05-01

    Mevalonic acid (MVA) is synthesized at an early and rate-limiting step in the biosynthesis of cholesterol by the enzyme hydroxymethylglutaryl coenzyme A (HMG-CoA) reductase, and is a useful measure of statin efficacy or treatment. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of serum MVA has been developed. Following the in vitro conversion of MVA to mevalonic acid lactone (MVAL) in the serum, MVAL and a deuterated internal standard were extracted using an online solid-phase extraction procedure. Chromatographic separation was achieved using a Luna PFP column (Phenomenex), with enhanced selectivity and improved resolution for polar compounds. A gradient system was used, with mobile phase comprising methanol and water (5 mmol/L ammonium formate buffer, pH 2.5). Analysis was performed using an API 5000 tandem mass spectrometer (Applied Biosystems) in positive electrospray ionization mode. The method showed excellent recoveries (98 ± 8%) and imprecision (intra-assay coefficient of variation of 2.2% [6.5 ng/mL] and 2.6% [10.5 ng/mL], and inter-assay coefficient of variation of 9% [10.5 ng/mL]). The assay provides a calibration range up to 50 ng/mL with a limit of detection at 0.1 ng/mL. A simple, rapid and analytically specific method has been developed for the measurement of serum MVA, in the form of MVAL. The high analytical sensitivity of the method allows for accurate quantitation of MVAL in serum samples, both at the endogenous levels found in healthy individuals and in statin-treated patients where normal levels are expected to be greatly reduced through the inhibition of HMG-CoA reductase.

  12. Photodegradation of multiclass fungicides in the aquatic environment and determination by liquid chromatography-tandem mass spectrometry.

    PubMed

    Celeiro, Maria; Facorro, Rocio; Dagnac, Thierry; Vilar, Vítor J P; Llompart, Maria

    2017-08-01

    The photodegradation behaviour for nine widespread fungicides (benalaxyl, cyprodinil, dimethomorph, fenhexamide, iprovalicarb, kresoxim-methyl, metalaxyl, myclobutanil and tebuconazole) was evaluated in different types of water. Two different systems, direct UV photolysis and UVC/H 2 O 2 advanced oxidation process (AOP), were applied for the photodegradation tests. For the monitoring of the target compound degradation, a method based on direct injection liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. Several fungicide photodegradation by-products were tentatively identified by high-resolution mass spectrometry (HRMS) as well. For the photolysis studies, the efficiency of different types of radiation, UVC (λ = 254 nm) and UVA (λ = 365 nm), was compared. UVC photolysis provided the highest removal with a complete degradation for fenhexamide and kresoxim-methyl, and percentages between 48 and 78% for the other compounds, excluding iprovalicarb and myclobutanil with removals <35%, after 30 min of irradiation. Besides, the photodegradation tests were performed with different initial concentrations of fungicides, and the efficiency of two photoreactor systems was compared. In all cases, the kinetics followed pseudo-first order, and the half-life times could also be calculated. The addition of H 2 O 2 under UVC light allowed an improvement of the reaction kinetics, especially for the most recalcitrant fungicides, obtaining in all cases removals higher than 82% in less than 6 min. Finally, in order to evaluate the suitability of the proposed systems, both UVC photolysis and UVC/H 2 O 2 system were tested in different real water matrices (wastewater, tap water, swimming pool water and river water), showing that the UVC/H 2 O 2 system had the highest removal efficiency in less than 6 min, for all water samples.

  13. Simultaneous determination of five plant growth regulators in fruits by modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Shi, Xiaomei; Jin, Fen; Huang, Yuting; Du, Xinwei; Li, Chunmei; Wang, Miao; Shao, Hua; Jin, Maojun; Wang, Jing

    2012-01-11

    An effective method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and optimized to obtain a complete separation of five representative plant growth regulators (PGRs) [gibberellic acid, 2,4-dichlorophenoxyacetic acid (2,4-D), thidiazuron, forchlorfenuron, and paclobutrazol] in fruits. Extraction was performed with acetonitrile containing 0.1% (v/v) acetic acid, applying modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) methodology. LC-MS/MS conditions including composition of mobile phases and mass spectrometry (MS) conditions were evaluated to achieve the highest sensitivity in MS detection. All of the data acquisition was employed in the segmented multiple-reaction monitoring mode for the selected negative and positive transition ions. The octadecylsilyl (C18) dispersive solid-phase extraction (SPE) sorbent was found to provide the more satisfied recoveries than primary secondary amine (PSA) and graphitized carbon black (GCB) for five target PGRs. The optimized method allowed for recoveries of 76-112% for the five PGRs from fruit samples with relative standard deviation (RSD) values less than 10%. Limits of quantification (0.5-16.5 μg/kg) were lower than the maximum limit of residues established for PGRs. The results demonstrated that the developed LC-MS/MS and QuEChERS extraction method is highly effective for analyzing trace amounts of target PGRs in fruit samples. Finally, the method was successfully used to detect residual PGRs in Beijing, China, in 2010. The concentrations of 2,4-D (5.1-1503 μg/kg) and paclobutrazol (1-1381 μg/kg) found in orange and peach, respectively, suggesting that the use of these PGRs in these fruits should be regulated in China in the future.

  14. Identification and Quantification of Gingerols and Related Compounds in Ginger Dietary Supplements Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    TAO, YI; LI, WENKUI; LIANG, WENZHONG; VAN BREEMEN, RICHARD B.

    2009-01-01

    Dietary supplements containing preparations of ginger roots/rhizomes (Zingiber officinale Roscoe) are being used by consumers, and clinical trials using ginger dietary supplements have been carried out to evaluate their anti-inflammatory or anti-emetic properties with inconsistent results. Chemical standardization of these products is needed for quality control and to facilitate the design of clinical trials and the evaluation of data from these studies. To address this issue, methods based on liquid chromatography-tandem mass spectrometry (LC-MS-MS) were developed for the detection, characterization and quantitative analysis of gingerol-related compounds in botanical dietary supplements containing ginger roots/rhizomes. During negative ion electrospray with collision induced-dissociation, the cleavage of the C4-C5 bond with a neutral loss of 194 u and benzylic cleavage leading to the neutral loss of 136 u were found to be class characteristic fragmentation patterns of the pharmacologically active gingerols or shogaols, respectively. Based on these results, an assay using LC-MS-MS with neutral loss scanning (loss of 194 u or 136 u) was developed that is suitable for the fingerprinting of ginger dietary supplements based on the selective detection of gingerols, shogaols, paradols, and gingerdiones. In addition, a quantitative assay based on LC-MS-MS with selected reaction monitoring was developed for the quantitative analysis of 6-gingerol, 8-gingerol, 10-gingerol, 6-shogaol, 8-shogaol, and 10-shogaol in ginger dietary supplements. After method validation, the quantities of these compounds in three commercially available ginger dietary supplements were determined. This assay showed excellent sensitivity, accuracy and precision and may be used to address the need for quality control and standardization of ginger dietary supplements. PMID:19817455

  15. Development of a pair of differential H/D isotope-coded derivatization reagents d(0)/d(3)-4-(1-methyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenlamine and its application for determination of aldehydes in selected aquatic products by liquid chromatography-tandem mass spectrometry.

    PubMed

    Sun, Zhiwei; Wang, Xiaoxiang; Cai, Yiping; Fu, Junqing; You, Jinmao

    2014-03-01

    A new pair of derivatization reagents, d0-4-(1-methyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenlamine (d0-MPIA) and d3-4-(1-methyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenlamine (d3-MPIA) have been designed and synthesized. It was successfully used to label aliphatic aldehydes and the aldehyde derivatives were analyzed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The new isotope-coded reagents could easily label aldehydes under acidic conditions in the presence of NaCNBH3. The target derivatives exhibited intense [M+H](+) and regular product ions with electrospray ionization source in positive mode. The d0/d3-MPIA-aldehydes were monitored by the transitions of [M+H](+)→m/z 322 and [M+H](+)→m/z 165, and the obtained detection limits were in the range of 0.18-15.9 pg/mL at signal to noise ratio of 3. The global isotope internal standard technology was employed for quantification analysis with d3-MPIA-aldehyde as internal standard for corresponding d0-MPIA-aldehyde. Excellent linear responses for relative quantification were observed in the range of 1/10-10/1 with coefficients >0.998. The developed method has been applied to the quantification of aliphatic aldehydes in selected aquatic products with RSD<3.6% and recoveries >85.2%. © 2013 Elsevier B.V. All rights reserved.

  16. Development of an ultrahigh-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous determination of salicylic acid, jasmonic acid, and abscisic acid in rose leaves.

    PubMed

    Bosco, Renato; Daeseleire, Els; Van Pamel, Els; Scariot, Valentina; Leus, Leen

    2014-07-09

    This paper describes a method to detect and quantitate the endogenous plant hormones (±)-2-cis-4-trans-abscisic acid, (-)-jasmonic acid, and salicylic acid by means of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in hybrid rose leaf matrices. Deuterium-labeled [(2)H6] (+)-2-cis-4-trans-abscisic acid, [(2)H6] (±)-jasmonic acid, and [(2)H4]-salicylic acid were used as internal standards. Rose samples (10 mg) were extracted with methanol/water/acetic acid (10:89:1) and subsequently purified on an Oasis MCX 1 cm(3) Vac SPE cartridge. Performance characteristics were validated according to Commission Decision 2002/657/EC. Recovery, repeatability, and within-laboratory reproducibility were acceptable for all phytohormones tested at three different concentrations. The decision limit and detection capability for (±)-2-cis-4-trans-abscisic acid, (-)-jasmonic acid, and salicylic acid were 0.0075 and 0.015 μg/g, 0.00015 and 0.00030 μg/g, and 0.0089 and 0.018 μg/g, respectively. Matrix effects (signal suppression or enhancement) appeared to be high for all substances considered, implying the need for quantitation based on matrix-matched calibration curves.

  17. Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.

    PubMed

    Kravtsova, Oxana Yu; Paramonov, Sergey A; Vasilevich, Natalya I; Kazyulkin, Denis N; Vlasova, Ekaterina; Engsig, Michael

    2013-12-01

    A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high-performance liquid chromatography-tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative-ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μM, 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10-5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra- and inter-day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4 ºС over 24 h, but it was unstable in solutions at room temperature during short-term storage (4 h) and several freeze-thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Analysis of intracellular and extracellular microcystin variants in sediments and pore waters by accelerated solvent extraction and high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zastepa, Arthur; Pick, Frances R; Blais, Jules M; Saleem, Ammar

    2015-05-04

    The fate and persistence of microcystin cyanotoxins in aquatic ecosystems remains poorly understood in part due to the lack of analytical methods for microcystins in sediments. Existing methods have been limited to the extraction of a few extracellular microcystins of similar chemistry. We developed a single analytical method, consisting of accelerated solvent extraction, hydrophilic-lipophilic balance solid phase extraction, and reversed phase high performance liquid chromatography-tandem mass spectrometry, suitable for the extraction and quantitation of both intracellular and extracellular cyanotoxins in sediments as well as pore waters. Recoveries of nine microcystins, representing the chemical diversity of microcystins, and nodularin (a marine analogue) ranged between 75 and 98% with one, microcystin-RR (MC-RR), at 50%. Chromatographic separation of these analytes was achieved within 7.5 min and the method detection limits were between 1.1 and 2.5 ng g(-1) dry weight (dw). The robustness of the method was demonstrated on sediment cores collected from seven Canadian lakes of diverse geography and trophic states. Individual microcystin variants reached a maximum concentration of 829 ng g(-1) dw on sediment particles and 132 ng mL(-1) in pore waters and could be detected in sediments as deep as 41 cm (>100 years in age). MC-LR, -RR, and -LA were more often detected while MC-YR, -LY, -LF, and -LW were less common. The analytical method enabled us to estimate sediment-pore water distribution coefficients (K(d)), MC-RR had the highest affinity for sediment particles (log K(d)=1.3) while MC-LA had the lowest affinity (log K(d)=-0.4), partitioning mainly into pore waters. Our findings confirm that sediments serve as a reservoir for microcystins but suggest that some variants may diffuse into overlying water thereby constituting a new route of exposure following the dissipation of toxic blooms. The method is well suited to determine the fate and persistence of different microcystins in aquatic systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Multiclass method for the determination of pharmaceuticals and personal care products in compost from sewage sludge using ultrasound and salt-assisted liquid-liquid extraction followed by ultrahigh performance liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Luque-Muñoz, A; Vílchez, J L; Zafra-Gómez, A

    2017-07-21

    An analytical method for the analysis of 16 pharmaceuticals and personal care products in compost from sewage sludge is successfully validated. Ultrasound assisted extraction with a mixture of acetonitrile:ethyl acetate (1:1, v/v) containing 10% (v/v) of acetic acid was carried out. Two cycles of extraction of 10min were applied. A clean-up of the extracts using salt-assisted liquid-liquid extraction (SALLE) was also included. Experimental design was used for the optimization of the main parameters involved in the extraction and cleaned-up steps. The chromatographic separation was carried out by ultrahigh performance liquid chromatography using a mobile phase gradient mixture of a 13mM buffer ammonium formate solution (pH 9.25) (solvent A) and methanol (solvent B). An ACQUITY UPLC ® BEH C18 column (1.7μm; 2.1×50mm) column was used. Analytes were separated in less than 11min. The compounds were detected and quantified using single reaction monitoring electrospray tandem mass spectrometry. The limits of detection calculated ranged from 0.5 to 4ngg -1 d.w., and the limits of quantification from 2 to 13ngg -1 d.w. Recoveries from 93% to 111%, with relative standar deviations lower than 11% in all cases, were obtained. The method was applied to natural compost samples. High concentrations of some analytes were found. Ketoprofen (510ngg -1 d.w.), methylparaben (240ngg -1 d.w.), diclofenac (175ngg -1 d.w.) and flufenamic acid (128ngg -1 d.w.) were the most abundant. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Development and application of an in-cell cleanup pressurized liquid extraction with ultra-high-performance liquid chromatography-tandem mass spectrometry to detect prohibited antiviral agents sensitively in livestock and poultry feces.

    PubMed

    Wu, Huizhen; Wang, Jianmei; Yang, Hua; Li, Guoqin; Zeng, Yinhuan; Xia, Wei; Li, Zuguang; Qian, Mingrong

    2017-03-10

    An in-cell cleanup pressurized liquid extraction was developed to analyze prohibited antiviral agents in livestock and poultry feces. Extraction and cleanup were integrated into one step. The extraction was performed using methanol-acetonitrile (1:1, v/v) with 0.5% glacial acetic acid at 90°C, and 0.75g of PSA was used as the adsorbent during the extraction procedure. Under optimal conditions, the average recoveries for 11 antiviral drugs were 71.5-112.5% at three spiked levels (20, 40, and 100μgkg -1 ). The detection limits and detection quantitations of the analysis method for the eleven antiviral drugs were 0.6-1.4 and 1.4-4.7μgkg -1 , respectively. Finally, the method was applied to analyze amantadine, oseltamivir and its metabolites oseltamivir acid in duck feces based on an experiment of an oral dose of two antiviral drugs in duck. The amantadine, oseltamivir and oseltamivir acid can be detected in feces within approximately four weeks after amantadine and oseltamivir were orally administered. The results indicate that the residue analysis in feces is a noninvasive method to monitor inhibited antiviral agents efficiently in livestock and poultry breeding. Copyright © 2017. Published by Elsevier B.V.

  1. Validated liquid chromatography-tandem mass spectrometry method for quantitative determination of dauricine in human plasma and its application to pharmacokinetic study.

    PubMed

    Liu, Xiaoying; Liu, Qian; Wang, Dongmei; Wang, Xueya; Zhang, Peng; Xu, Haiyan; Zhao, Hui; Zhao, Huaiqing

    2010-05-01

    A highly sensitive and selective LC-MS/MS method was developed and validated for the determination of dauricine in human plasma, using protopine as internal standard (IS). The analyte and IS were extracted by liquid-liquid extraction and analyzed by LC-MS/MS. Chromatographic separation was performed on Agilent TC-C(18) column with a mobile phase of methanol-water-glacial acetic acid (60:40:0.8, v/v/v) at a flow rate of 0.7 mL/min. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring (MRM) mode using the electrospray ionization technique in positive mode. The method was linear over the concentration range of 1-200 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL in human plasma with acceptable precision and accuracy. The intra- and inter-day precision was less than 5.9% determined from quality control (QC) samples at concentrations of 2.0, 20.0 and 160 ng/mL, and the accuracy was within +/-9.9%. This method was successfully applied for the evaluation of pharmacokinetics of dauricine after oral doses of 100, 300 and 600 mg phenolic alkaloids of menispermum dauricum tablet (PAMDT) to 12 Chinese healthy volunteers. 2010 Elsevier B.V. All rights reserved.

  2. Determination of tigecycline in turkey plasma by LC-MS/MS: validation and application in a pharmacokinetic study.

    PubMed

    Jasiecka-Mikołajczyk, A; Jaroszewski, J J

    2017-03-01

    Tigecycline (TIG), a novel glycylcycline antibiotic, plays an important role in the management of complicated skin and intra-abdominal infections. The available data lack any description of a method for determination of TIG in avian plasma. In our study, a selective, accurate and reversed-phase high performance liquid chromatography-tandem mass spectrometry method was developed for the determination of TIG in turkey plasma. Sample preparation was based on protein precipitation and liquid-liquid extraction using 1,2-dichloroethane. Chromatographic separation of TIG and minocycline (internal standard, IS) was achieved on an Atlantis T3 column (150 mm × 3.0 mm, 3.0 μm) using gradient elution. The selected reaction monitoring transitions were performed at 293.60 m/z → 257.10 m/z for TIG and 458.00 m/z → 441.20 m/z for IS. The developed method was validated in terms of specificity, selectivity, linearity, lowest limit of quantification, limit of detection, precision, accuracy, matrix effect, carry-over effect, extraction recovery and stability. All parameters of the method submitted to validation met the acceptance criteria. The assay was linear over the concentration range of 0.01-100 μg/ml. This validated method was successfully applied to a TIG pharmacokinetic study in turkey after intravenous and oral administration at a dose of 10 mg/kg at various time-points.

  3. Rapid determination of fumonisins in corn-based products by liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Wei; Herrman, Timothy J; Dai, Susie Y

    2010-01-01

    A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.

  4. Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column.

    PubMed

    Hao, Chunyan; Morse, David; Morra, Franca; Zhao, Xiaoming; Yang, Paul; Nunn, Brian

    2011-08-19

    Analysis of the broad-spectrum herbicide glyphosate and its related compounds is quite challenging. Tedious and time-consuming derivatization is often required for these substances due to their high polarity, high water solubility, low volatility and molecular structure which lacks either a chromophore or fluorophore. A novel liquid chromatography/tandem mass spectrometry (LC/MS-MS) method has been developed for the determination of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate using a reversed-phase and weak anion-exchange mixed-mode Acclaim® WAX-1 column. Aqueous environmental samples are directly injected and analyzed in 12 min with no sample concentration or derivatization steps. Two multiple reaction monitoring (MRM) channels are monitored in the method for each target compound to achieve true positive identification, and ¹³C, ¹⁵N-glyphosate is used as an internal standard to carry out isotope dilution mass spectrometric (IDMS) measurement for glyphosate. The instrument detection limits (IDLs) for glyphosate, AMPA and glufosinate are 1, 2 and 0.9 μg/L, respectively. Linearity of the detector response with a minimum coefficient of determination (R² value (R² > 0.995) was demonstrated in the range of ∼10 to 10³ μg/L for each analytes. Spiked drinking water, surface water and groundwater samples were analyzed using this method and the average recoveries of analytes in three matrices ranged from 77.0 to 102%, 62.1 to 101%, 66.1 to 93.7% while relative standard deviation ranged from 6.3 to 10.2%, 2.7 to 14.8%, 2.9 to 10.7%, respectively. Factors that may affect method performance, such as metal ions, sample preservation, and storage time, are also discussed. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  5. Quantitative determination of carcinogenic mycotoxins in human and animal biological matrices and animal-derived foods using multi-mycotoxin and analyte-specific high performance liquid chromatography-tandem mass spectrometric methods.

    PubMed

    Cao, Xiaoqin; Li, Xiaofei; Li, Jian; Niu, Yunhui; Shi, Lu; Fang, Zhenfeng; Zhang, Tao; Ding, Hong

    2018-01-15

    A sensitive and reliable multi-mycotoxin-based method was developed to identify and quantify several carcinogenic mycotoxins in human blood and urine, as well as edible animal tissues, including muscle and liver tissue from swine and chickens, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). For the toxicokinetic studies with individual mycotoxins, highly sensitive analyte-specific LC-MS/MS methods were developed for rat plasma and urine. Sample purification consisted of a rapid 'dilute and shoot' approach in urine samples, a simple 'dilute, evaporate and shoot' approach in plasma samples and a 'QuEChERS' procedure in edible animal tissues. The multi-mycotoxin and analyte-specific methods were validated in-house: The limits of detection (LOD) for the multi-mycotoxin and analyte-specific methods ranged from 0.02 to 0.41 μg/kg (μg/L) and 0.01 to 0.19 μg/L, respectively, and limits of quantification (LOQ) between 0.10 to 1.02 μg/kg (μg/L) and 0.09 to 0.47 μg/L, respectively. Apparent recoveries of the samples spiked with 0.25 to 4 μg/kg (μg/L) ranged from 60.1% to 109.8% with relative standard deviations below 15%. The methods were successfully applied to real samples. To the best of our knowledge, this is the first study carried out using a small group of patients from the Chinese population with hepatocellular carcinoma to assess their exposure to carcinogenic mycotoxins using biomarkers. Finally, the multi-mycotoxin method is a useful analytical method for assessing exposure to mycotoxins edible in animal tissues. The analyte-specific methods could be useful during toxicokinetic and toxicological studies. Copyright © 2017. Published by Elsevier B.V.

  6. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    EPA Science Inventory

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  7. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    PubMed

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  8. Quantitative determination of galantamine in human plasma by sensitive liquid chromatography-tandem mass spectrometry using loratadine as an internal standard.

    PubMed

    Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh

    2007-02-01

    A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.

  9. Analysis of defense signals in Arabidopsis thaliana leaves by ultra-performance liquid chromatography/tandem mass spectrometry: jasmonates, salicylic acid, abscisic acid.

    PubMed

    Stingl, Nadja; Krischke, Markus; Fekete, Agnes; Mueller, Martin J

    2013-01-01

    Defense signaling compounds and phytohormones play an essential role in the regulation of plant responses to various environmental abiotic and biotic stresses. Among the most severe stresses are herbivory, pathogen infection, and drought stress. The major hormones involved in the regulation of these responses are 12-oxo-phytodienoic acid (OPDA), the pro-hormone jasmonic acid (JA) and its biologically active isoleucine conjugate (JA-Ile), salicylic acid (SA), and abscisic acid (ABA). These signaling compounds are present and biologically active at very low concentrations from ng/g to μg/g dry weight. Accurate and sensitive quantification of these signals has made a significant contribution to the understanding of plant stress responses. Ultra-performance liquid chromatography (UPLC) coupled with a tandem quadrupole mass spectrometer (MS/MS) has become an essential technique for the analysis and quantification of these compounds.

  10. Segmental analysis of amphetamines in hair using a sensitive UHPLC-MS/MS method.

    PubMed

    Jakobsson, Gerd; Kronstrand, Robert

    2014-06-01

    A sensitive and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxy methamphetamine in hair samples. Segmented hair (10 mg) was incubated in 2M sodium hydroxide (80°C, 10 min) before liquid-liquid extraction with isooctane followed by centrifugation and evaporation of the organic phase to dryness. The residue was reconstituted in methanol:formate buffer pH 3 (20:80). The total run time was 4 min and after optimization of UHPLC-MS/MS-parameters validation included selectivity, matrix effects, recovery, process efficiency, calibration model and range, lower limit of quantification, precision and bias. The calibration curve ranged from 0.02 to 12.5 ng/mg, and the recovery was between 62 and 83%. During validation the bias was less than ±7% and the imprecision was less than 5% for all analytes. In routine analysis, fortified control samples demonstrated an imprecision <13% and control samples made from authentic hair demonstrated an imprecision <26%. The method was applied to samples from a controlled study of amphetamine intake as well as forensic hair samples previously analyzed with an ultra high performance liquid chromatography time of flight mass spectrometry (UHPLC-TOF-MS) screening method. The proposed method was suitable for quantification of these drugs in forensic cases including violent crimes, autopsy cases, drug testing and re-granting of driving licences. This study also demonstrated that if hair samples are divided into several short segments, the time point for intake of a small dose of amphetamine can be estimated, which might be useful when drug facilitated crimes are investigated. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Novel capsule phase microextraction in combination with liquid chromatography-tandem mass spectrometry for determining personal care products in environmental water.

    PubMed

    Lakade, Sameer S; Borrull, Francesc; Furton, Kenneth G; Kabir, Abuzar; Marcé, Rosa Maria; Fontanals, Núria

    2018-05-01

    A novel sample preparation technique named capsule phase microextraction (CPME) is presented here. The technique utilizes a miniaturized microextraction capsule (MEC) as the extraction medium. The MEC consists of two conjoined porous tubular polypropylene membranes, one of which encapsulates the sorbent through sol-gel technology, while the other encapsulates a magnetic metal rod. As such, MEC integrates both the extraction and stirring mechanisms into a single device. The aim of this article is to demonstrate the application potential of CPME as sample preparation technique for the extraction of a group of personal care products (PCPs) from water matrices. Among the different sol-gel sorbent materials (UCON ® , poly(caprolactone-dimethylsiloxane-caprolactone) (PCAP-DMS-CAP) and Carbowax 20M (CW-20M)) evaluated, CW-20M MEC demonstrated the best extraction performance for the selected PCPs. The extraction conditions for sol-gel CW-20M MEC were optimized, including sample pH, stirring speed, addition of salt, extraction time, sample volume, liquid desorption solvent, and time. Under the optimal conditions, sol-gel CW-20M MEC provided recoveries, ranging between 47 and 90% for all analytes, except for ethylparaben, which showed a recovery of 26%. The method based on CPME with sol-gel CW-20M followed by liquid chromatography-tandem mass spectrometry was developed and validated for the extraction of PCPs from river water and effluent wastewater samples. When analyzing different environmental samples, some analytes such as 2,4-dihydroxybenzophenone, 2,2-dihydroxy-4-4 methoxybenzophenone and 3-benzophenone were found at low ng L -1 .

  12. Reagent for Evaluating Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Performance in Bottom-Up Proteomic Experiments.

    PubMed

    Beri, Joshua; Rosenblatt, Michael M; Strauss, Ethan; Urh, Marjeta; Bereman, Michael S

    2015-12-01

    We present a novel proteomic standard for assessing liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrument performance, in terms of chromatographic reproducibility and dynamic range within a single LC-MS/MS injection. The peptide mixture standard consists of six peptides that were specifically synthesized to cover a wide range of hydrophobicities (grand average hydropathy (GRAVY) scores of -0.6 to 1.9). A combination of stable isotope labeled amino acids ((13)C and (15)N) were inserted to create five isotopologues. By combining these isotopologues at different ratios, they span four orders of magnitude within each distinct peptide sequence. Each peptide, from lightest to heaviest, increases in abundance by a factor of 10. We evaluate several metrics on our quadrupole orbitrap instrument using the 6 × 5 LC-MS/MS reference mixture spiked into a complex lysate background as a function of dynamic range, including mass measurement accuracy (MMA) and the linear range of quantitation of MS1 and parallel reaction monitoring experiments. Detection and linearity of the instrument routinely spanned three orders of magnitude across the gradient (500 fmol to 0.5 fmol on column) and no systematic trend was observed for MMA of targeted peptides as a function of abundance by analysis of variance analysis (p = 0.17). Detection and linearity of the fifth isotopologue (i.e., 0.05 fmol on column) was dependent on the peptide and instrument scan type (MS1 vs PRM). We foresee that this standard will serve as a powerful method to conduct both intra-instrument performance monitoring/evaluation, technology development, and inter-instrument comparisons.

  13. Online liquid chromatography-tandem mass spectrometry cyanide determination in blood.

    PubMed

    Lacroix, C; Saussereau, E; Boulanger, F; Goullé, J P

    2011-04-01

    An original liquid chromatography-tandem mass spectrometry (LC-MS-MS) method coupled to online extraction has been developed for cyanide determination in blood. A method involving fluorimetric detection after naphthalene-2,3-dicarboxyaldehyde (NDA) complexation by taurine in the presence of cyanide was previously described. Its performance was limited because of the absence of an internal standard (IS). Using cyanide isotope (13)C(15)N as IS allowed quantification in MS-MS. After the addition of (13)C(15)N, 25 μL of blood were diluted in water and deproteinized with methanol. Following derivatization with NDA and taurine for 10 min at 4°C, 100 μL was injected into the online LC-MS-MS system. An Oasis HLB was used as an extraction column, and a C18 Atlantis was the analytical column. The chromatographic cycle was performed with an ammonium formate (20 mM, pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 6 min. Detection was performed in negative electrospray ionization mode (ESI(-)) with a Quattro Micro. For quantification, transitions of derivatives formed with CN and (13)C(15)N were monitored, respectively, as follows: 299.3/191.3 and 301.3/193.3. The procedure was fully validated, linear from 26 to 2600 ng/mL with limit of detection of 10 ng/mL. This method, using a small blood sample, is not only simple, but also time saving. The specificity and sensitivity of LC-MS-MS coupled to online extraction and using (13)C(15)N as the IS make this method very suitable for cyanide determination in blood and could be useful in forensic toxicology.

  14. Determination of artemisitene in rat plasma by ultra-performance liquid chromatography/tandem mass spectrometry and its application in pharmacokinetics.

    PubMed

    Wu, Li-Lan; Wu, Yun-Shan; Chen, Wei-Ying; Zhou, Wen; Tang, Lipeng; Li, Ben; Liu, Bo

    2017-07-15

    Artemisitene shows a wide variety of pharmacological activities, such as antioxidant protection in vitro and in vivo. It has been identified as a novel Nrf2 inducer. However, there is no report on an ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method to quantitate artemisitene in rat plasma and its application to a pharmacokinetic profile study. An ACQUITY UPLC™ BEH Symmetry Shield RP18 column (1.7 μm, 2.1 mm × 100 mm) was used at a flow rate of 0.3 mL·min -1 . Mass detection was performed by electrospray ionization tandem mass spectrometry via multiple reaction monitoring (MRM) in positive mode. Plasma samples were pre-treated by a single-step extraction with 0.1% formic acid aqueous solutions-acetonitrile, and tolbutamide was used as internal standard. The calibration curve was from 0.98 to 1000 ng∙mL -1 (r 2  = 0.995). The extraction recoveries were 61.5-79.4% and 81.7-94.6% for artemisitene and tolbutamide, respectively. The lower limit of quantification (LLOQ) was 0.98 ng∙mL -1 . The absolute bioavailability of artemisitene was 3.7% after intravenous and oral administration in rats. The UPLC/MS/MS assay was validated for linearity, accuracy, stability, extraction recovery, matrix effects, and intra-day and inter-day precision. The method, for the first time, achieved some pharmacokinetic parameters and was successfully applied to a pharmacokinetic study Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays.

    PubMed

    Yang, Liyu; Amad, Ma'an; Winnik, Witold M; Schoen, Alan E; Schweingruber, Hans; Mylchreest, Iain; Rudewicz, Patrick J

    2002-01-01

    Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (

  16. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-03-01

    A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Determination of perchlorate from tea leaves using quaternary ammonium modified magnetic carboxyl-carbon nanotubes followed by liquid chromatography-tandem quadrupole mass spectrometry.

    PubMed

    Zhao, Yong-Gang; Zhang, Yun; Wang, Feng-Lian; Zhou, Jian; Zhao, Qi-Ming; Zeng, Xiu-Qiong; Hu, Mei-Qin; Jin, Mi-Cong; Zhu, Yan

    2018-08-01

    The novel quaternary ammonium modified magnetic carboxyl-carbon nanotubes (QA-Mag-CCNTs) have been synthesised and characterized. QA-Mag-CCNTs were applied in magnetic dispersive solid phase extraction (Mag-dSPE) for preconcentration of perchlorate from tea leaves prior to liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) analysis. The Mag-dSPE procedure for preconcentration of perchlorate succeed in overcoming the flaw (containing target analyte randomly) of commercially available SPE cartridge. Under optimal conditions, the results showed higher extraction efficiency of QA-Mag-CCNTs, with recoveries between 85.2% and 107%. And the satisfactory precision with inter-day and intra-day RSD values were lower than 8.0%. Furthermore, QA-Mag-CCNTs were evaluated for reuse up to 20 times. The limit of quantification (LOQ) for perchlorate was 8.21 ng kg -1 . The developed method was successfully applied in tea leaves for food-safety risk monitoring in Zhejiang province, China. The results showed the concentrations of perchlorate in 229 out of 240 collected samples were in the range of 0.082-988 μg kg -1 . It was confirmed that QA-Mag-CCNTs were highly effective materials used for preconcentration of perchlorate. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Evaluation of treadmill exercise effect on muscular lipid profiles of diabetic fatty rats by nanoflow liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lee, Jong Cheol; Kim, Il Yong; Son, Yeri; Byeon, Seul Kee; Yoon, Dong Hyun; Son, Jun Seok; Song, Han Sol; Song, Wook; Seong, Je Kyung; Moon, Myeong Hee

    2016-07-01

    We compare comprehensive quantitative profiling of lipids at the molecular level from skeletal muscle tissues (gastrocnemius and soleus) of Zucker diabetic fatty rats and Zucker lean control rats during treadmill exercise by nanoflow liquid chromatography-tandem mass spectrometry. Because type II diabetes is caused by decreased insulin sensitivity due to excess lipids accumulated in skeletal muscle tissue, lipidomic analysis of muscle tissues under treadmill exercise can help unveil the mechanism of lipid-associated insulin resistance. In total, 314 lipid species, including phospholipids, sphingolipids, ceramides, diacylglycerols (DAGs), and triacylglycerols (TAGs), were analyzed to examine diabetes-related lipid species and responses to treadmill exercise. Most lysophospholipid levels increased with diabetes. While DAG levels (10 from the gastrocnemius and 13 from the soleus) were >3-fold higher in diabetic rats, levels of most of these decreased after exercise in soleus but not in gastrocnemius. Levels of 5 highly abundant TAGs (52:1 and 54:3 in the gastrocnemius and 48:2, 50:2, and 52:4 in the soleus) displaying 2-fold increases in diabetic rats decreased after exercise in the soleus but not in the gastrocnemius in most cases. Thus, aerobic exercise has a stronger influence on lipid levels in the soleus than in the gastrocnemius in type 2 diabetic rats.

  19. Detection and identification of drugs and toxicants in human body fluids by liquid chromatography-tandem mass spectrometry under data-dependent acquisition control and automated database search.

    PubMed

    Oberacher, Herbert; Schubert, Birthe; Libiseller, Kathrin; Schweissgut, Anna

    2013-04-03

    Systematic toxicological analysis (STA) is aimed at detecting and identifying all substances of toxicological relevance (i.e. drugs, drugs of abuse, poisons and/or their metabolites) in biological material. Particularly, gas chromatography-mass spectrometry (GC/MS) represents a competent and commonly applied screening and confirmation tool. Herein, we present an untargeted liquid chromatography-tandem mass spectrometry (LC/MS/MS) assay aimed to complement existing GC/MS screening for the detection and identification of drugs in blood, plasma and urine samples. Solid-phase extraction was accomplished on mixed-mode cartridges. LC was based on gradient elution in a miniaturized C18 column. High resolution electrospray ionization-MS/MS in positive ion mode with data-dependent acquisition control was used to generate tandem mass spectral information that enabled compound identification via automated library search in the "Wiley Registry of Tandem Mass Spectral Data, MSforID". Fitness of the developed LC/MS/MS method for application in STA in terms of selectivity, detection capability and reliability of identification (sensitivity/specificity) was demonstrated with blank samples, certified reference materials, proficiency test samples, and authentic casework samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Rapid quantitative analysis of 8-iso-prostaglandin-F(2alpha) using liquid chromatography-tandem mass spectrometry and comparison with an enzyme immunoassay method.

    PubMed

    Dahl, Jeffrey H; van Breemen, Richard B

    2010-09-15

    A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the measurement of urinary 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)), a biomarker of lipid peroxidation. Because urine contains numerous F(2) prostaglandin isomers, each with identical mass and similar mass spectrometric fragmentation patterns, chromatographic separation of 8-iso-PGF(2alpha) from its isomers is necessary for its quantitative analysis using MS/MS. We were able to achieve this separation using an isocratic LC method with a run time of less than 9min, which is at least threefold faster than previous methods, while maintaining sensitivity, accuracy, precision, and reliability. The limits of detection and quantitation were 53 and 178pg/ml urine, respectively. We compared our method with a commercially available affinity purification and enzyme immunoassay kit and found both assays to be in agreement. Despite the high sensitivity of the enzyme immunoassay method, it is more expensive and has a narrower dynamic range than LC-MS/MS. Our method was optimized for rapid measurement of 8-iso-PGF(2alpha) in urine, and it is ideally suited for clinical sample analysis. 2010 Elsevier Inc. All rights reserved.

  1. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    PubMed

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  2. Determination of mycotoxins in plant-based beverages using QuEChERS and liquid chromatography-tandem mass spectrometry.

    PubMed

    Miró-Abella, Eugènia; Herrero, Pol; Canela, Núria; Arola, Lluís; Borrull, Francesc; Ras, Rosa; Fontanals, Núria

    2017-08-15

    A method was developed for the simultaneous determination of 11 mycotoxins in plant-based beverage matrices, using a QuEChERS extraction followed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry detection (UHPLC-(ESI)MS/MS). This multi-mycotoxin method was applied to analyse plant-based beverages such as soy, oat and rice. QuEChERS extraction was applied obtaining suitable extraction recoveries between 80 and 91%, and good repeatability and reproducibility values. Method Quantification Limits were between 0.05μgL -1 (for aflatoxin G 1 and aflatoxin B 1 ) and 15μgL -1 (for deoxynivalenol and fumonisin B 2 ). This is the first time that plant-based beverages have been analysed, and certain mycotoxins, such as deoxynivalenol, aflatoxin B 1 , aflatoxin B 2 , aflatoxin G 1 , aflatoxin G 2 , ochratoxin A, T-2 toxin and zearalenone, were found in the analysed samples, and some of them quantified between 0.1μgL -1 and 19μgL -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Quantification of six herbicide metabolites in human urine.

    PubMed

    Norrgran, Jessica; Bravo, Roberto; Bishop, Amanda M; Restrepo, Paula; Whitehead, Ralph D; Needham, Larry L; Barr, Dana B

    2006-01-18

    We developed a sensitive, selective and precise method for measuring herbicide metabolites in human urine. Our method uses automated liquid delivery of internal standards and acetate buffer and a mixed polarity polymeric phase solid phase extraction of a 2 mL urine sample. The concentrated eluate is analyzed using high-performance liquid chromatography-tandem mass spectrometry. Isotope dilution calibration is used for quantification of all analytes. The limits of detection of our method range from 0.036 to 0.075 ng/mL. The within- and between-day variation in pooled quality control samples range from 2.5 to 9.0% and from 3.2 to 16%, respectively, for all analytes at concentrations ranging from 0.6 to 12 ng/mL. Precision was similar with samples fortified with 0.1 and 0.25 ng/mL that were analyzed in each run. We validated our selective method against a less selective method used previously in our laboratory by analyzing human specimens using both methods. The methods produced results that were in agreement, with no significant bias observed.

  4. Rapid determination of five antibiotic residues in swine wastewater by online solid-phase extraction-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Tagiri-Endo, Misako; Suzuki, Shigeru; Nakamura, Tomoyuki; Hatakeyama, Takashi; Kawamukai, Kazuo

    2009-02-01

    A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 microl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01-0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.

  5. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    PubMed

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were <0.2-2.3 µg/L. The results of the present study indicated that the proposed method was suitable for determining bromate concentrations in drinking water without sample pretreatment.

  6. Analysis of non-steroidal anti-inflammatory drugs in milk using QuEChERS and liquid chromatography coupled to mass spectrometry: triple quadrupole versus Q-Orbitrap mass analyzers.

    PubMed

    Rúbies, Antoni; Guo, Lili; Centrich, Francesc; Granados, Mercè

    2016-08-01

    We developed a Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method for the high throughput determination of 10 non-steroidal anti-inflammatory drugs (NSAIDs) in milk samples using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with a triple quadrupole (QqQ) instrument and an electrospray ionization (ESI) source. The new extraction procedure is highly efficient, and we obtained absolute recoveries in the range 78.1-97.1 % for the extraction and clean-up steps. Chromatographic separation is performed in the gradient mode with a biphenyl column and acidic mobile phases consisting of water and acetonitrile containing formic acid. The chromatographic run time was about 12 min, and NSAID peaks showed a good symmetry factor. For MS/MS detection, we used multiple reaction monitoring (MRM) mode, using ESI in both positive and negative modes. Our method has been validated in compliance with the European Commission Decision 657/2002/EC, and we obtained very satisfactory results in inter-laboratory testing. Furthermore, we explored the use of a hybrid high resolution mass spectrometer, combining a quadrupole and an Orbitrap mass analyzer, for high resolution (HR) MS/MS detection of NSAIDs. We achieved lower NSAID quantification limits with Q-Orbitrap high resolution mass spectrometry (HRMS/MS) detection than those achieved with the QqQ instrument; however, its main feature is its very high selectivity, which makes HRMS/MS particularly suitable for confirmatory analysis.

  7. Removal of detergents from proteins and peptides in a spin-column format.

    PubMed

    Antharavally, Babu S

    2012-08-01

    To enable downstream analysis, it is critical to remove unbound detergents from protein and peptide samples. This unit describes the use of a high-performance resin that offers exceptional detergent removal for proteins and peptides. The easy-to-use spin format significantly improves results over the standard drip column and batch methodologies, with >95% removal of 1% to 5% detergents, including SDS, sodium deoxycholate, CHAPS, Triton X-100, Triton X-114, NP-40, Brij-35, octyl glucoside, octyl thioglucoside, and lauryl maltoside, with high recovery of proteins and peptides. Detergent removal efficiency is evaluated using colorimetric methods and mass spectrometry (MS). BSA tryptic peptides have been successfully analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and matrix-assisted laser desorption/ionization (MALDI)-MS for identification of protein, following detergent removal using the resin. Advantages of this method include speed (less than 15 min), efficient detergent removal, and high recovery of proteins and peptides. © 2012 by John Wiley & Sons, Inc.

  8. Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Bihan, Kevin; Lu, Qin; Enjalbert, Manon; Apparuit, Maxime; Langeron, Olivier; Rouby, Jean-Jacques; Funck-Brentano, Christian; Zahr, Noël

    2016-12-01

    Colistin is a polypeptide antibiotic from the polymyxin E group used for the treatment of infections caused by multidrug-resistant gram-negative bacteria. The main constituents, accounting for approximately 85% of this mixture, are colistin A (polymyxin E1) and colistin B (polymyxin E2). The aim of this study was to develop and validate new and fast methods of quantification of colistin A and B and its precursors [colistin methanesulfonate sodium (CMS) A and B] by ultraperformance liquid chromatography-tandem mass spectrometry in plasma and urine with short pretreatment and run times. Chromatography was performed on an Acquity UPLC-MS/MS system (WATERS) with a WATERS Acquity UPLC C18 column (4.6 × 150 mm, 3.5 μm particle size). The pretreatment of samples consists of precipitation and extraction into microcolumns plate and HLB 96-well plate 30 μm-30 mg (OASIS) with a Positive Pressure-96 (WATERS). Quantification was performed using a multiple reaction monitoring of the following transitions: m/z 390.9 → 385.1 for colistin A, m/z 386.2 → 101.0 for colistin B, and m/z 602.4 → 241.1 for polymyxin B1 sulfate. In plasma and urine, calibration curves were linear from 30 to 6000 ng/mL for colistin A and from 15 to 3000 ng/mL for colistin B. With an acceptable accuracy and precision, the lower limit of quantification were set at 24.0 ng/mL and 12.0 ng/mL for colistin A and B in plasma, and at 18.0 ng/mL and 9.0 ng/mL for colistin A and B in urine. These LC-MS/MS methods of quantification for colistin A and B and its precursors (CMS A and B) in plasma and urine are fast, simple, specific, sensitive, accurate, precise, and reliable. Furthermore, they are linear and repeatable. These procedures were successfully applied to a pharmacokinetic study of a critically ill patient suffering from ventilator-associated pneumonia, who was treated with nebulized CMS.

  9. An optimized method for the accurate determination of patulin in apple products by isotope dilution-liquid chromatography/mass spectrometry.

    PubMed

    Seo, Miyeong; Kim, Byungjoo; Baek, Song-Yee

    2015-07-01

    Patulin, a mycotoxin produced by several molds in fruits, has been frequently detected in apple products. Therefore, regulatory bodies have established recommended maximum permitted patulin concentrations for each type of apple product. Although several analytical methods have been adopted to determine patulin in food, quality control of patulin analysis is not easy, as reliable certified reference materials (CRMs) are not available. In this study, as a part of a project for developing CRMs for patulin analysis, we developed isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC/MS/MS) as a higher-order reference method for the accurate value-assignment of CRMs. (13)C7-patulin was used as internal standard. Samples were extracted with ethyl acetate to improve recovery. For further sample cleanup with solid-phase extraction (SPE), the HLB SPE cartridge was chosen after comparing with several other types of SPE cartridges. High-performance liquid chromatography was performed on a multimode column for proper retention and separation of highly polar and water-soluble patulin from sample interferences. Sample extracts were analyzed by LC/MS/MS with electrospray ionization in negative ion mode with selected reaction monitoring of patulin and (13)C7-patulin at m/z 153→m/z 109 and m/z 160→m/z 115, respectively. The validity of the method was tested by measuring gravimetrically fortified samples of various apple products. In addition, the repeatability and the reproducibility of the method were tested to evaluate the performance of the method. The method was shown to provide accurate measurements in the 3-40 μg/kg range with a relative expanded uncertainty of around 1%.

  10. Environmental analysis of alcohol ethoxylates and nonylphenol ethoxylate metabolites by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lara-Martín, Pablo A; González-Mazo, Eduardo; Brownawell, Bruce J

    2012-03-01

    Surfactants and their metabolites can be found in aquatic environments at relatively high concentrations compared with other micropollutants due in part to the exceptionally large volumes produced every year. We have focused our attention here on the most widely used nonionic surfactants, alcohol ethoxylates (AEOs), and on nonylphenol ethoxylate (NPEO) degradation products (short-chain nonylphenol ethoxylates, NP1-3EO, nonylphenol, NP, and nonylphenol ethoxycarboxylates, NP1-2EC), which are endocrine-disrupting compounds. Our main objective in this work was to develop a methodology aimed at the extraction, isolation, and improved analysis of these analytes in environmental samples at trace levels. Extraction recoveries of target compounds were determined for sediment samples after ultrasonic extraction and purification using HLB or C18 solid-phase extraction minicolumns. Recovery percentages were usually between 61 and 102% but were lower for longer AEO ethoxymers. Identification and quantification of target compounds was carried out using a novel ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS-MS) approach, a combination that provides higher sensitivity and faster analysis than prior methods using conventional high-performance liquid chromatography-mass spectrometry. Limits of detection were usually below 0.5 ng/g, being higher for monoethoxylate species (>5 ng/g) because of poor ionization. The method was used for analyzing surface sediment samples collected at Jamaica Bay (NY) in 2008. The highest values (28,500 ng/g for NP, 4,200 ng/g for NP1-3EO, 22,400 ng/g for NP1-2EC, and 1,500 ng/g for AEOs) were found in a sampling station from a restricted water circulation area that is heavily impacted by wastewater discharges.

  11. Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.

    PubMed

    Bloom, Erica; Nyman, Eva; Must, Aime; Pehrson, Christina; Larsson, Lennart

    2009-11-01

    Mycotoxins are toxic, secondary metabolites frequently produced by molds in water-damaged indoor environments. We studied the prevalence of selected, potent mycotoxins and levels of fungal biomass in samples collected from water-damaged indoor environments in Sweden during a 1-year period. One hundred samples of building materials, 18 samples of settled dust, and 37 samples of cultured dust were analyzed for: (a) mycoflora by microscopy and culture; (b) fungal chemical marker ergosterol and hydrolysis products of macrocyclic trichothecenes and trichodermin (verrucarol and trichodermol) by gas chromatography-tandem mass spectrometry; and (c) sterigmatocystin, gliotoxin, aflatoxin B(1), and satratoxin G and H by high performance liquid chromatography-tandem mass spectrometry. Sixty-six percent of the analyzed building materials samples, 11% of the settled dust samples, and 51% of the cultured dust samples were positive for at least one of the studied mycotoxins. In addition, except in the case of gliotoxin, mycotoxin-positive building material samples contained 2-6 times more ergosterol than mycotoxin-negative samples. We show that (a) molds growing on a range of different materials indoors in water-damaged buildings generally produce mycotoxins, and (b) mycotoxin-containing particles in mold-contaminated environments may settle on surfaces above floor level. The mass spectrometry methods used in this study are valuable tools in further research to survey mycotoxin exposure and investigate potential links with health effects.

  12. Multiplex Liquid Chromatography-Tandem Mass Spectrometry Assay for Simultaneous Therapeutic Drug Monitoring of Ribavirin, Boceprevir, and Telaprevir

    PubMed Central

    Aouri, Manel; Moradpour, Darius; Cavassini, Matthias; Mercier, Thomas; Buclin, Thierry; Csajka, Chantal; Telenti, Amalio; Rauch, Andri

    2013-01-01

    New directly acting antivirals (DAAs) that inhibit hepatitis C virus (HCV) replication are increasingly used for the treatment of chronic hepatitis C. A marked pharmacokinetic variability and a high potential for drug-drug interactions between DAAs and numerous drug classes have been identified. In addition, ribavirin (RBV), commonly associated with hemolytic anemia, often requires dose adjustment, advocating for therapeutic drug monitoring (TDM) in patients under combined antiviral therapy. However, an assay for the simultaneous analysis of RBV and DAAs constitutes an analytical challenge because of the large differences in polarity among these drugs, ranging from hydrophilic (RBV) to highly lipophilic (telaprevir [TVR]). Moreover, TVR is characterized by erratic behavior on standard octadecyl-based reversed-phase column chromatography and must be separated from VRT-127394, its inactive C-21 epimer metabolite. We have developed a convenient assay employing simple plasma protein precipitation, followed by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of levels of RBV, boceprevir, and TVR, as well as its metabolite VRT-127394, in plasma. This new, simple, rapid, and robust HPLC-MS/MS assay offers an efficient method of real-time TDM aimed at maximizing efficacy while minimizing the toxicity of antiviral therapy. PMID:23629707

  13. Analysis of glycosaminoglycans in cerebrospinal fluid from patients with mucopolysaccharidoses by isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Haoyue; Young, Sarah P; Auray-Blais, Christiane; Orchard, Paul J; Tolar, Jakub; Millington, David S

    2011-07-01

    New therapies for the treatment of mucopolysaccharidoses that target the brain, including intrathecal enzyme replacement, are being explored. Quantitative analysis of the glycosaminoglycans (GAGs) that accumulate in these disorders is required to assess the disease burden and monitor the effect of therapy in affected patients. Because current methods lack the required limit of quantification and specificity to analyze GAGs in small volumes of cerebrospinal fluid (CSF), we developed a method based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples of CSF (25 μL) were evaporated to dryness and subjected to methanolysis. The GAGs were degraded to uronic acid-N-acetylhexosamine dimers and mixed with internal standards derived from deuteriomethanolysis of GAG standards. Specific dimers derived from heparan, dermatan and chondroitin sulfates (HS, DS and CS) were separated by UPLC and analyzed by electrospray ionization MS/MS using selected reaction monitoring for each targeted GAG product and its corresponding internal standard. CSF from control pediatric subjects (n = 22) contained <0.38 mg/L HS, 0.26 mg/L DS, and 2.8 mg/L CS, whereas CSF from patients with Hurler syndrome (n = 7) contained concentrations of DS and HS that were at least 6-fold greater than the upper control limits. These concentrations were reduced by 17.5% to 82.5% after allogeneic transplantation and treatment with intrathecal and intravenous enzyme replacement therapy. The method described here has potential value in monitoring patients with mucopolysaccharidoses receiving treatment targeted to the brain.

  14. Determination of ribavirin in chicken muscle by quick, easy, cheap, effective, rugged and safe method and liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Yin-Liang; Chen, Ruo-Xia; Zhu, Lie; Lv, Yan; Zhu, Yong; Zhao, Jian

    2016-02-15

    A new analytical method for the determination of ribavirin in chicken muscle using a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed and validated. Samples were extracted with acidified methanol (methanol:acetic acid, 99:1, v/v). The extract was further purified by QuEChERS method using primary-secondary amine (PSA) and C18. Finally, the extract was dried by nitrogen under 45°C and reconstituted in water. The separation was performed on a Hypercarb analytical column under a gradient elution. The mobile phase was composed of water buffered with ammonium acetate (2.0mM) and acetonitrile. The proposed method was validated according to the European Commission Decision 2002/657/EC. The values of the decision limit (CCα) and the detection capability (CCβ) were 1.1 and 1.5μg/kg, respectively. The mean recoveries of ribavirin ranged from 94.2% to 99.2%. The repeatability (expressed as coefficient of variation, CVr) of the method ranged from 4.5% to 4.9% and the reproducibility (CVR) of the method ranged from 4.8% to 5.4%. The method is demonstrated to be suitable for the determination of ribavirin in chicken muscle in conformity with the current EU performance requirements through validation. The total time required for the analysis of one sample, including sample preparation, was about 45min. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Validated ultra-performance liquid chromatography-tandem mass spectrometry method for analyzing LSD, iso-LSD, nor-LSD, and O-H-LSD in blood and urine.

    PubMed

    Chung, Angela; Hudson, John; McKay, Gordon

    2009-06-01

    The Royal Canadian Mounted Police Forensic Science and Identification Services was looking for a confirmatory method for lysergic acid diethylamide (LSD). As a result, an ultra-performance liquid chromatography-tandem mass spectrometry method was validated for the confirmation and quantitation of LSD, iso-LSD, N-demethyl-LSD (nor-LSD), and 2-oxo-3-hydroxy-LSD (O-H-LSD). Relative retention time and ion ratios were used as identification parameters. Limits of detection (LOD) in blood were 5 pg/mL for LSD and iso-LSD and 10 pg/mL for nor-LSD and O-H-LSD. In urine, the LOD was 10 pg/mL for all analytes. Limits of quantitation (LOQ) in blood and urine were 20 pg/mL for LSD and iso-LSD and 50 pg/mL for nor-LSD and O-H-LSD. The method was linear, accurate, and precise from 10 to 2000 pg/mL in blood and 20 to 2000 pg/mL in urine for LSD and iso-LSD and from 20 to 2000 pg/mL in blood and 50 to 2000 pg/mL in urine for nor-LSD and O-H-LSD with a coefficient of determination (R(2)) > or = 0.99. The method was applied to blinded biological control samples and biological samples taken from a suspected LSD user. This is the first reported detection of O-H-LSD in blood from a suspected LSD user.

  16. Stereoselective pharmacokinetic study of rhynchophylline and isorhynchophylline epimers in rat plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Xin; Zheng, Mei; Liu, Jia; Qiao, Zhou; Liu, Wenyuan; Feng, Feng

    2017-06-01

    1. In this study, the stereoselective pharmacokinetics of rhynchophylline (RIN) and isorhynchophylline (IRN) in rat plasma were investigated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). 2. A rapid, robust and sensitive LC-MS/MS method for simultaneous quantification of RIN and IRN in rat plasma was established and validated. Chromatographic separation was performed on a Poroshell 120 EC-C 18 column under a gradient elution with methanol and water containing 0.01% ammonia as mobile phase. Calibration curve was linear over a concentration range of 1-2000 ng/mL for both epimers. 3. After intravenous administration, there was no apparent difference in pharmacokinetic parameters between two epimers. However, after oral administration, RIN showed remarkable higher plasma exposure than IRN. The bioavailability, C max and AUC 0- t of RIN were about 9.2-fold, 6.4-fold and 9.1-fold higher than those of IRN at 10 mg/kg, and 7.8-fold, 4.3-fold and 7.7-fold at 20 mg/kg, respectively. Additionally, with dosage enhanced from 10 mg/kg to 20 mg/kg, the plasma concentrations of RIN or IRN increased significantly and the bioavailability enhanced about three times. 4. In conclusion, the results of this work demonstrated for the first time that the pharmacokinetics of RIN and IRN have stereoselectivity.

  17. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2009-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, and the other modified tyrosines were then quantified with isotopic dilution methods. MRM peaks of the modified tyrosines (DiY, NY, BrY, and DiBrY) from human urine were measured and the elution times coincided with the authentic and isotopic standards. The amounts of modified tyrosines in healthy human urine (n = 23) were 8.8 +/- 0.6 (DiY), 1.4 +/- 0.4 (NY), 3.8 +/- 0.3 (BrY), and 0.7 +/- 0.1 (DiBrY) micromol/mol of creatinine, respectively. A comparison of the modified tyrosines with urinary 8-oxo-deoxyguanosine, pentosidine, and N(epsilon)-(hexanoyl)lysine was also performed. Almost all products, except for NY, showed good correlations with each other. The amounts of the modified tyrosines (NY, BrY, and DiBrY) in the diabetic urine were higher than those in the urine from healthy people.

  18. Liquid chromatography-tandem mass spectrometry for the quantification of moxifloxacin, ciprofloxacin, daptomycin, caspofungin, and isavuconazole in human plasma.

    PubMed

    Hösl, Julian; Gessner, André; El-Najjar, Nahed

    2018-05-12

    A simple and precise ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the simultaneous analysis of five anti-infective agents used to treat severe infections [three antibiotics (daptomycin, moxifloxacin, ciprofloxacin) and two antifungals (isavuconazole, caspofungin)] in human plasma. Sample preparation was based on protein precipitation with ice cold methanol. All five agents were analyzed with the corresponding isotopically labeled internal standards. All analytes were detected in multiple reactions monitoring (MRM) using API 4000 triple-quadrupole mass spectrometer with electrospray (ESI) source operating in positive mode. The calibration curves were linear over the selected ranges (r > 0.99). The method is precise and accurate with a total run time of 5.5 min. Accuracy of all target analytes ranged between 95.9-116.6%, measured with an imprecision of less than 10.8%. The lower limit of quantification was 1.25 mg/L for caspofungin, 0.3125 mg/L for isavuconazole, 3.125 mg/L for daptomycin, 0.075 mg/L for ciprofloxacin, and 0.1875 mg/L for moxifloxacin. The successful application of the method in patient samples proved its suitability for the medical surveillance of antimicrobial therapy in intensive care units as well as to other pharmacokinetic studies. Copyright © 2018. Published by Elsevier B.V.

  19. Combination of solvent extractants for dispersive liquid-liquid microextraction of fungicides from water and fruit samples by liquid chromatography with tandem mass spectrometry.

    PubMed

    Pastor-Belda, Marta; Garrido, Isabel; Campillo, Natalia; Viñas, Pilar; Hellín, Pilar; Flores, Pilar; Fenoll, José

    2017-10-15

    A multiresidue method was developed to determine twenty-five fungicides belonging to three different chemical families, oxazoles, strobilurins and triazoles, in water and fruit samples, using dispersive liquid-liquid microextraction (DLLME) and liquid chromatography/tandem mass spectrometry (LC-MS 2 ). Solid-liquid extraction with acetonitrile was used for the analysis in fruits, the extract being used as dispersant solvent in DLLME. Since some of the analytes showed high affinity for chloroform and the others were more efficiently extracted with undecanol, a mixture of both solvents was used as extractant in DLLME. After evaporation of CHCl 3 , the enriched phase was analyzed. Enrichment factors in the 23-119 and 12-60 ranges were obtained for waters and fruits, respectively. The approach was most sensitive for metominostrobin with limits of quantification of 1ngL -1 and 5ngkg -1 in waters and fruits, respectively, while a similar sensitivity was attained for tebuconazole in fruits. Recoveries of the fungicides varied between 86 and 116%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Simultaneous determination of osthole, bergapten and isopimpinellin in rat plasma and tissues by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Jing; Ma, Bo; Zhang, Qi; Yang, Xiaojing; Sun, Jingjing; Tang, Bowen; Cui, Guangbo; Yao, Di; Liu, Lei; Gu, Guiying; Zhu, Jianwei; Wei, Ping; Ouyang, Pingkai

    2014-11-01

    A highly selective and sensitive method for simultaneous quantitation of osthole, bergapten and isopimpinellin in rat plasma and tissues was developed by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). After liquid-liquid extraction of samples with methyl tert-butyl ether, the analytes and dextrorphan (internal standard, IS) were separated by a Hypersil GOLD AQ C18 column with gradient elution of acetonitrile and water containing 0.5‰ formic acid. Three determinands were detected using an electrospray ionization (ESI) tandem mass spectrometry in the multiple reaction monitoring (MRM) modes with positive electrospray ionization. Calibration curves were recovered over the concentration ranges of 1-200 ng/ml, 1-500 ng/ml, 0.25-200 ng/ml for osthole, bergapten and isopimpinellin in plasma; 1-100 ng/ml, 1-500 ng/ml, 0.5-100 ng/ml for osthole, bergapten and isopimpinellin in tissues, respectively. The intra-day precision (R.S.D.) was within 13.90% and the intra-day accuracy (R.E.) was within -6.27 to 6.84% in all biological matrixes. The inter-day precision (R.S.D.) was less than 13.66% and the inter-day accuracy (R.E.) was within -10.64 to 13.04%. Then the method was successfully applied to investigate plasma pharmacokinetic study and tissue distribution of osthole, bergapten and isopimpinellin in rats after oral administration of Fructus Cnidii extraction, especially for testis/uterus tissue distribution. The results demonstrated that osthole, bergapten and isopimpinellin were absorbed and eliminated rapidly with wide distributions in rats. Distribution data of these three bioactive components in testis/uterus tissues could offer useful information for the further preclinical and clinical studies of Fructus Cnidii in the treatment of genital system disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Application of a novel liquid chromatography/tandem mass spectrometry method for the determination of antazoline in human plasma: Result of ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study.

    PubMed

    Giebułtowicz, Joanna; Piotrowski, Roman; Baran, Jakub; Kułakowski, Piotr; Wroczyński, Piotr

    2016-05-10

    Antazoline is a first-generation antihistaminic agent with antiarrhythmic quinidine-like properties. In some countries, it is widely used for termination of cardiac arrhythmias, especially atrial fibrillation (AF). However, no human pharmacokinetic studies have been conducted with intravenous antazoline. The aim of our study was to develop and validate a novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of antazoline in human plasma: the ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study. Antazoline was extracted from plasma using liquid-liquid extraction. The concentration of the analyte was measured by LC-MS/MS with xylometazoline as an internal standard. The method was validated for linearity, precision, accuracy, stability (freeze/thaw stability, stability in autosampler, short and long term stability), dilution integrity and matrix effect. The analyzed validation criteria were fulfilled. The method was applied to a pharmacokinetic study involving 10 healthy volunteers. Following a single intravenous dose of antazoline mesylate (100 mg), the plasma concentration profile showed a relative fast elimination with a terminal elimination half-life of 2.29 h. A relatively high volume of distribution was observed (Vss=315 L). The values of mean residence time (MRT∞), area under the curve (AUC∞) and clearance were 3.45 h, 0.91 mg h L(-1) and 80.5 L h(-1), respectively. One volunteer showed significant differences in pharmacokinetic parameters. In conclusion, the proposed new LC-MS/MS method was successfully used for the first time for the determination of antazoline in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Simultaneous determination of trantinterol and its metabolites in rat urine and feces by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Kunjie; Wang, Yanjuan; Zhang, Lili; Qin, Feng; Guo, Xingjie; Li, Famei

    2013-09-01

    A highly selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of trantinterol (SPFF) and its major metabolites for the first time. The analytes were extracted from rat urine and feces samples by liquid-liquid extraction (LLE) and determined in multiple reaction monitoring (MRM) mode with clenbuterol as the internal standard. Chromatographic separation was achieved on a Venusil ASB C8 column (2.1mm×100mm, 3μm), with the mobile phase consisted of methanol-0.2% formic acid (30:70, v/v) at the flow rate of 0.2mL/min. Each sample was chromatographed within 5min. This method has a lower limit of quantification (LLOQ) of 0.450, 1.05, 1.35, 0.904 and 1.36ng/mL for trantinterol (SPFF), arylhydroxylamine trantinterol (N-OH-SPFF), tert-butyl hydroxylated trantinterol (Tert-OH-SPFF), 1-carbonyl trantinterol (SPFF-COOH) and 3-methyl sulfone-dechloro-trantinterol (SPFF-SO2CH3) in rat urine, and 0.450, 1.35 and 0.904ng/mL for SPFF, Tert-OH-SPFF and SPFF-COOH in rat feces, respectively. The linear correlation coefficients were greater than 0.990. The intra- and inter-day precision (relative standard deviation, RSD) values were below 15% and the accuracy (relative error, RE) was -9.9% to 11% at three quality control levels. The method has been successfully applied to the excretion study following an oral administration of 1mg/kg trantinterol to rats. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Measurement of salivary cortisol level for the diagnosis of critical illness-related corticosteroid insufficiency in children.

    PubMed

    Gunnala, Vishal; Guo, Rong; Minutti, Carla; Durazo-Arvizu, Ramon; Laporte, Cynthia; Mathews, Herbert; Kliethermis, Stephanie; Bhatia, Rahul

    2015-05-01

    To compare serum total, serum free and salivary cortisol in critically ill children. Prospective observational cohort study. Tertiary pediatric critical care unit at Ronald McDonald Children's Hospital at Loyola University Medical Center. We enrolled 59 patients (4 weeks to 18 years of age) between January 2012 and May 2013. Thirty-four patients were included in the salivary to serum free cortisol correlational analysis. Blood and saliva samples were obtained simultaneously within 24 hours of admission between the hours of 6 AM and 12 PM. Salivary cortisol was tested by liquid chromatography/tandem mass spectrometry, serum free cortisol by liquid chromatography/tandem mass spectrometry followed by equilibrium dialysis, and serum total cortisol by liquid chromatography/tandem mass spectrometry. Salivary and serum free cortisol values from 34 patients had a correlation coefficient (r) of 0.87 (95% CI, 0.75-0.93; p < 0.0001). The total serum and salivary cortisol values had a correlation coefficient (r) of 0.67 (95% CI, 0.42-0.81; p < 0.0001). The total serum and serum free cortisol values had a correlation coefficient (r) of 0.83 (95% CI, 0.69-0.91; p < 0.0001). Serum free and salivary cortisol values correlate in critically ill children. Salivary cortisol can be used as a surrogate for serum free cortisol in critically ill pediatric patients. Salivary cortisol is a cost-effective and less invasive measure of bioavailable cortisol and offers an alternate and accurate method for assessing critical illness-related corticosteroid insufficiency in children.

  4. Rapid detection of multiple class pharmaceuticals in both municipal wastewater and sludge with ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Yuan, Xiangjuan; Qiang, Zhimin; Ben, Weiwei; Zhu, Bing; Liu, Junxin

    2014-09-01

    This work described the development, optimization and validation of an analytical method for rapid detection of multiple-class pharmaceuticals in both municipal wastewater and sludge samples based on ultrasonic solvent extraction, solid-phase extraction, and ultra high performance liquid chromatography-tandem mass spectrometry quantification. The results indicated that the developed method could effectively extract all the target pharmaceuticals (25) in a single process and analyze them within 24min. The recoveries of the target pharmaceuticals were in the range of 69%-131% for wastewater and 54%-130% for sludge at different spiked concentration levels. The method quantification limits in wastewater and sludge ranged from 0.02 to 0.73ng/L and from 0.02 to 1.00μg/kg, respectively. Subsequently, this method was validated and applied for residual pharmaceutical analysis in a wastewater treatment plant located in Beijing, China. All the target pharmaceuticals were detected in the influent samples with concentrations varying from 0.09ng/L (tiamulin) to 15.24μg/L (caffeine); meanwhile, up to 23 pharmaceuticals were detected in sludge samples with concentrations varying from 60ng/kg (sulfamethizole) to 8.55mg/kg (ofloxacin). The developed method demonstrated its selectivity, sensitivity, and reliability for detecting multiple-class pharmaceuticals in complex matrices such as municipal wastewater and sludge. Copyright © 2014. Published by Elsevier B.V.

  5. The application of chiral ultra-high-performance liquid chromatography tandem mass spectrometry to the separation of the zoxamide enantiomers and the study of enantioselective degradation process in agricultural plants.

    PubMed

    Pan, Xinglu; Dong, Fengshou; Chen, Zenglong; Xu, Jun; Liu, Xingang; Wu, Xiaohu; Zheng, Yongquan

    2017-11-24

    In this study, an effective and sensitive chiral analytical method was developed to detect zoxamide enantiomers in vegetables, fruits and environmental matrices using ultra-high-performance liquid chromatography-tandem mass spectrometry. Optimal separation conditions were achieved with Lux Amylose-2 chiral column using acetonitrile/water (70:30v/v) as mobile phase with a flow rate and column temperature of 0.5mL/min and 25°C. The absolute configuration, optical rotation and elution order were confirmed for the first time. The average recoveries in all matrices at four spiking levels (0.5, 5, 50, 250μg/kg) ranged from 89.7 to 117.4%, with relative standard deviations being less than 10.9% for two enantiomers. The enantioselective dissipation of zoxamide in tomato showed that (-)-R-zoxamide was preferentially degraded leading to an enrichment of (+)-S-isomer, with half-lives of 3.80 d and 5.17 d, respectively. Inversely, (+)-S-zoxamide degraded faster than (-)-R-zoxamide in pepper (1.95day and 2.28day, respectively) and grape (2.03day and 2.87day). No significant enantioselectivity was observed in cucumber. The results of this study could help facilitate more accurate risk assessments of zoxamide in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. [Determination of perfluoroalkyl acids in lamb liver by high performance liquid chromatography- tandem mass spectrometry combined with dispersive solid phase extraction].

    PubMed

    Zhu, Pingping; Yue, Zhenfeng; Zheng, Zongkun; Zhang, Yi; Li, Wenyin; Zhao, Fengjuan; Xiao Chengui; Bai, Runye; Lin, Wei

    2015-05-01

    A method was developed for the determination of 19 perfluoroalkyl acids (PFAs) in lamb liver by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/ MS) combined with dispersive solid phase extraction. The sample was extracted with acidified acetonitrile, and then cleaned-up by a mixture of N-propylethylenediamine (PSA), C18 and graphitized carbon black (GCB) sorbents. The 19 PFAs were analyzed by HPLC-MS/MS with a C18 chromatographic column, adopting the multiple reaction monitoring (MRM) mode with negative electrospray ionization. The effects of the dosages of hydrochloric acid and the sorbents on the recoveries of the 19 PFAs were studied. For accurate quantitative analysis, the isotope internal standard method was used. The calibration curves were linear with the correlation coefficients over 0.998 in the range of 0.05-20 µg/kg for the 19 PFAs. The limits of detection were 0.004-0.111 µg/kg. The limits of quantification were 0.012-0.370 µg/kg. The mean recoveries of the 19 PFAs at spiked levels of 0.5, 1.0, 2.0 µg/kg were in the range from 80% to 128% with the relative standard deviations of 0.31%-11.1%. The developed method is rapid, simple, accurate. It is suitable for the determination of the 19 PFAs in large quantities of lamb liver samples.

  7. A high performance liquid chromatography tandem mass spectrometry for the quantification of tacrolimus in human bile in liver transplant recipients.

    PubMed

    Tron, Camille; Rayar, Michel; Petitcollin, Antoine; Beaurepaire, Jean-Marie; Cusumano, Caterina; Verdier, Marie-Clémence; Houssel-Debry, Pauline; Camus, Christophe; Boudjema, Karim; Bellissant, Eric; Lemaitre, Florian

    2016-12-02

    Tacrolimus whole-blood concentrations imperfectly reflect concentrations at the effect site. Tacrolimus concentrations in the transplanted organ could be more relevant to predict rejection events. Because liver biopsy cannot be repeatedly performed after liver transplantation, we suggested measuring tacrolimus in the bile to have a cost-effective and clinically implementable surrogate marker of intra-hepatic tacrolimus concentration. We developed and fully validated a liquid chromatography-tandem mass spectrometry method for the determination of tacrolimus in human bile. Sample purification was achieved using protein precipitation and liquid-liquid extraction with ethyl-acetate. Gradient elution was performed using a C18 analytical column with a 5min run-time. The method was linear from 0.5ng/mL to 20ng/mL. In this concentration range, within-day and between-day precisions as well as overall bias were within ±15%. Matrix effect was fully corrected by the internal standard (ascomycin). The assay was optimized to achieve good selectivity in this complex biological matrix. Tacrolimus was found to be stable in bile stored 6 months at -80°C, after 3 freeze and thaw cycles, 20h at room temperature and 24h in extracts kept at 15°C in the auto-sampler. The method was applied to quantify tacrolimus in bile from liver transplant recipients. It allowed getting preliminary data about tacrolimus excretion profile in bile and showed the lack of correlation between tacrolimus whole blood concentration and tacrolimus liver exposition. This alternative and innovative analytical approach of tacrolimus bio-analysis appears suitable for further studies evaluating relevance of biliary tacrolimus concentration as a new pharmacological marker of immunosuppressive activity. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Determination of a novel nonfluorinated quinolone, nemonoxacin, in human feces and its glucuronide conjugate in human urine and feces by high-performance liquid chromatography-triple quadrupole mass spectrometry.

    PubMed

    He, Gaoli; Guo, Beining; Yu, Jicheng; Zhang, Jing; Wu, Xiaojie; Cao, Guoying; Shi, Yaoguo; Tsai, Cheng-Yuan

    2015-05-01

    Three methods were developed and validated for determination of nemonoxacin in human feces and its major metabolite, nemonoxacin acyl-β- d-glucuronide, in human urine and feces. Nemonoxacin was extracted by liquid-liquid extraction in feces homogenate samples and nemonoxacin acyl-β- d-glucuronide by a solid-phase extraction procedure for pretreatment of both urine and feces homogenate sample. Separation was performed on a C18 reversed-phase column under isocratic elution with the mobile phase consisting of acetonitrile and 0.1% formic acid. Both analytes were determined by liquid chromatography-tandem mass spectrometry with positive electrospray ionization in selected reaction monitoring mode and gatifloxacin as the internal standard. The lower limit of quantitation (LLOQ) of nemonoxacin in feces was 0.12 µg/g and the calibration curve was linear in the concentration range of 0.12-48.00 µg/g. The LLOQ of the metabolite was 0.0010 µg/mL and 0.03 µg/g in urine and feces matrices, while the linear range was 0.0010-0.2000 µg/mL and 0.03-3.00 µg/g, respectively. Validation included selectivity, accuracy, precision, linearity, recovery, matrix effect, carryover, dilution integrity and stability, indicating that the methods can quantify the corresponding analytes with excellent reliability. The validated methods were successfully applied to an absolute bioavailability clinical study of nemonoxacin malate capsule. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Determination of pharmaceutical and illicit drugs in oral fluid by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Di Corcia, D; Lisi, S; Pirro, V; Gerace, E; Salomone, A; Vincenti, M

    2013-05-15

    A simple and extremely fast procedure for the quantitative determination in oral fluid samples of 44 substances, including the most common drugs of abuse and several pharmaceutical drugs, was developed and fully validated. Preliminary sample treatment was limited to protein precipitation. The resulting acetonitrile solution was directly injected into an ultra-high performance liquid chromatograph (UHPLC) equipped with a C18 column (100mm×2.1mm, 1.7μm). The mobile phase eluted with linear gradient (water/formic acid 5mM: acetonitrile/formic acid 5mM; v:v) from 98:2 to 0:100 in 5.0min, followed by isocratic elution at 100% B for 1.0min. The flow rate was 0.6mL/min and the total run time was 9.0min including re-equilibration at the initial conditions. The analytes were revealed by a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The method proved to be simple, accurate, rapid and highly sensitive, allowing the simultaneous detection of all compounds. The ease of sample treatment, together with the wide range of detectable substances, all with remarkable analytical sensitivity, make this procedure ideal for the screening of large populations in several forensic and clinical contexts, whenever oral fluid sampling has to be preferred to blood sampling, as for example in short retrospective investigations. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Licit and illicit drugs in a wastewater treatment plant in Verona, Italy.

    PubMed

    Repice, Carla; Dal Grande, Mario; Maggi, Roberto; Pedrazzani, Roberta

    2013-10-01

    The occurrence of 12 active substances among licit and illicit drugs was investigated over a 2 week period inflowing and outflowing in an activated sludge wastewater treatment plant in the city of Verona, Northern Italy. Chemical analyses were performed by means of on-line solid phase extraction coupled to high performance liquid chromatography-tandem mass spectrometry in order to minimize sample pre-treatment. Quantifiable concentrations, up to hundreds of ng/L, were detected in influent and in effluent only for carbamazepine, codeine and benzoylecgonine. Such values are in accordance with literature data, so as removal efficiencies: it was observed that there was pretty much no abatement for carbamazepine, while average removal percentages of about 60% and 90% were calculated for codeine and benzoylecgonine, respectively. These results provide useful information (also concerning some active principles never or rarely detected, up to now, such as lormetazepam) for integrated water cycle managing, also taking into account the specific characteristics of the receiving water basin. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    NASA Astrophysics Data System (ADS)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  12. A survey of liquid chromatographic-mass spectrometric analysis of mercapturic acid biomarkers in occupational and environmental exposure monitoring.

    PubMed

    Mathias, Patricia I; B'Hymer, Clayton

    2014-08-01

    High-performance liquid chromatography/mass spectrometry (HPLC/MS) is sensitive and specific for targeted quantitative analysis and is readily utilized for small molecules from biological matrices. This brief review describes recent selected HPLC/MS methods for the determination of urinary mercapturic acids (mercapturates) which are useful as biomarkers in characterizing human exposure to electrophilic industrial chemicals in occupational and environmental studies. Electrophilic compounds owing to their reactivity are used in chemical and industrial processes. They are present in industrial emissions, are combustion products of fossil fuels, and are components in tobacco smoke. Their presence in both the industrial and general environments are of concern for human and environmental health. Urinary mercapturates which are the products of metabolic detoxification of reactive chemicals provide a non-invasive tool to investigate human exposure to electrophilic toxicants. Selected recent mercapturate quantification methods are summarized and specific cases are presented. The biological formation of mercapturates is introduced and their use as biomarkers of metabolic processing of electrophilic compounds is discussed. Also, the use of liquid chromatography/tandem mass spectrometry in simultaneous determinations of the mercapturates of multiple parent compounds in a single determination is considered, as well as future trends and limitations in this area of research. Published by Elsevier B.V.

  13. Novel UHPLC-MS/MS method for the determination of rotigotine in the plasma of patients with Parkinson's disease.

    PubMed

    Mohamed, Susan; Riva, Roberto; Contin, Manuela

    2017-09-01

    A novel ultra-high-pressure liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of the dopamine receptor agonist rotigotine in human plasma. Following liquid-liquid extraction with tert-butyl methyl ether from 500 μL plasma, the chromatographic analysis was performed on a Gemini NX3 column using 5 mm pH 5.0 ammonium acetate-5 mm ammonium acetate in methanol as binary gradient mobile phase, at a flow rate of 0.3 mL/min. The MS/MS ion transitions were 316.00 → 147.00 for rotigotine and 256.10 → 211.00 for the internal standard (lamotrigine). The lower limit of quantitation was 50 pg/mL and the linearity was determined from 50 to 2500 pg/mL. The mean recovery was 96.9%. Both intra- and interassay imprecision and inaccuracy were ≤15% at all quality control concentrations. The method was successfully applied to measure morning trough plasma rotigotine concentrations in a series of patients with Parkinson's disease on chronic treatment. The present study describes the first fully validated method for rotigotine determination in human plasma. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Quantitative determination of four nitrofuran metabolites in meat by isotope dilution liquid chromatography-electrospray ionisation-tandem mass spectrometry.

    PubMed

    Mottier, Pascal; Khong, Seu-Ping; Gremaud, Eric; Richoz, Janique; Delatour, Thierry; Goldmann, Till; Guy, Philippe A

    2005-03-04

    A confirmatory method based on isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the low-level determination of residues of four nitrofuran veterinary drugs in meat, e.g., furazolidone, furaltadone, nitrofurantoin, and nitrofurazone. The procedure entails an acid-catalysed release of protein-bound metabolites, followed by their in situ conversion into the 2-nitrobenzaldehyde (NBA) imine-type derivatives. Liquid-liquid extraction and clean-up on a polymeric solid phase extraction cartridge are then performed before LC-MS/MS analysis by positive electrospray ionisation (ESI) applying multiple reaction monitoring of three transition reactions for each compound. Reliable quantitation is obtained by using one deuterated analogue per analyte (d4-NBA derivative) as internal standard (IS). Validation of the method in chicken meat was conducted following the European Union (EU) criteria for the analysis of veterinary drug residues in foods. The decision limits (CCalpha) were 0.11-0.21 microg/kg, and the detection capabilities (CCbeta) 0.19-0.36 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the EU. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.

  15. Determination of artificial sweeteners in sewage sludge samples using pressurised liquid extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Ordoñez, Edgar Y; Quintana, José Benito; Rodil, Rosario; Cela, Rafael

    2013-12-13

    An analytical method for the determination of six artificial sweeteners in sewage sludge has been developed. The procedure is based on pressurised liquid extraction (PLE) with water followed by solid-phase extraction (SPE) and subsequent liquid chromatography-tandem mass spectrometry analysis. After optimisation of the different PLE parameters, extraction with aqueous 500mM formate buffer (pH 3.5) at 80°C during a single static cycle of 21min proved to be best conditions. After a subsequent SPE, quantification limits, referred to dry weight (dw) of sewage sludge, ranged from 0.3ng/g for acesulfame (ACE) to 16ng/g for saccharin (SAC) and neohespiridine dihydrochalcone. The trueness, expressed as recovery, ranged between 72% and 105% and the precision, expressed as relative standard deviation, was lower than 16%. Moreover, the method proved its linearity up to the 2μg/g range. Finally, the described method was applied to the determination of the artificial sweeteners in primary and secondary sewage sludge from urban wastewater treatment plants. Four of the six studied artificial sweeteners (ACE, cyclamate, SAC and sucralose) were found in the samples at concentrations ranging from 17 to 628ng/g dw. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Simultaneous determination of five synthetic pyrethroid metabolites in urine by liquid chromatography-tandem mass spectrometry: application to 39 persons without known exposure to pyrethroids.

    PubMed

    Le Grand, R; Dulaurent, S; Gaulier, J M; Saint-Marcoux, F; Moesch, C; Lachâtre, G

    2012-04-25

    A sensitive and reliable method was developed and validated for the determination of five synthetic pyrethroid metabolites namely cis-Cl(2)CA, trans-Cl(2)CA, Br(2)CA, 3-PBA and 4-FPBA in human urine by liquid chromatography-tandem mass spectrometry. (2)D(6)-labelled trans-Cl(2)CA and (13)C(6)-labelled 3-PBA were used as internal standards. This method was based on a liquid-liquid extraction procedure in acidic conditions using hexane solvent with a basic purification, a chromatographic separation using a specific C18 column and mass spectrometric detection in the negative polarity. Suitable limits of detection (0.015μg/L for the five compounds) and quantification (from 0.020 to 0.030μg/L) were obtained for rendering the method usable for the biomonitoring of pyrethroids in the general population. The efficiency of the method was tested in 39 urine samples from French people without any known exposure to pyrethroids. At least three of the five metabolites were detected in each sample. The results of this study were compared to those obtained in previous ones and discussed. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. A high-performance liquid chromatography-tandem mass spectrometry method coupled with protein precipitation for determination of granisetron in human plasma and its application to a comparative pharmacokinetic study.

    PubMed

    Zhou, Ying; Jiang, Ji; Hu, Pei; Wang, Hongyun

    2014-12-01

    A rapid, simple and validated method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has been developed for the determination of granisetron in human plasma. Plasma samples were pre-purified by protein precipitation procedure. The chromatographic separation was achieved with Synergi Polar-RP (75 × 2 mm, 4 µm) column using a mixture of 5 mm pH4.0 ammonium formate and methanol (300:316, v/v) under isocratic conditions at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The analysis time was about 2.5 min. The method was fully validated over the concentration range 0.1-10 ng/mL. The lower limit of quantification was 0.1 ng/mL. Inter- and intra-batch precision was <6.1% and the accuracy was within 95.6-100.0%. The mean extraction recovery was 96.3%. Selectivity, matrix effect and stability were also validated. The method was applied to the comparative pharmacokinetic study of granisetron in Chinese healthy subjects. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Simultaneous determination of sixteen metabolites related to neural tube defects in maternal serum by liquid chromatography coupling with electrospray tandem mass spectrometry.

    PubMed

    Liang, Xiao-Ping; Liang, Qiong-Lin; Xia, Jian-Fei; Wang, Yong; Hu, Ping; Wang, Yi-Ming; Zheng, Xiao-Ying; Zhang, Ting; Luo, Guo-An

    2009-06-15

    Disturbances in maternal folate, homocysteine, and glutathione metabolism have been reported to be associated with neural tube defects (NTDs). However, the role played by specific components in the metabolic pathways leading to NTDs remains unclear. Thus an analytical method for simultaneous measurement of sixteen compounds involved in such three metabolic pathways by high performance liquid chromatography-tandem mass spectrometry was developed. The use of hydrophilic chromatography column improved the separation of polar analytes and the detection mode of multiple-reaction monitoring (MRM) enhanced the specificity and sensitivity so as to achieve simultaneous determination of three class of metabolites which have much variance in polarity and contents. The influence of parameters such as temperature, pH, flow rate on the performance of the analytes were studied to get an optimal condition. The method was validated for its linearity, accuracy, and precision, and also used for the analysis of serum samples of NTDs-affected pregnancies and normal women. The result showed that the present method is sensitive and reliable for simultaneous determination of as many as sixteen interesting metabolites which may provide a new means to study the underlying mechanism of NTDs as well as to discover new potential biomarkers.

  19. Solid-phase extraction combined with dispersive liquid-liquid microextraction and chiral liquid chromatography-tandem mass spectrometry for the simultaneous enantioselective determination of representative proton-pump inhibitors in water samples.

    PubMed

    Zhao, Pengfei; Deng, Miaoduo; Huang, Peiting; Yu, Jia; Guo, Xingjie; Zhao, Longshan

    2016-09-01

    This report describes, for the first time, the simultaneous enantioselective determination of proton-pump inhibitors (PPIs-omeprazole, lansoprazole, pantoprazole, and rabeprazole) in environmental water matrices based on solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME) and chiral liquid chromatography-tandem mass spectrometry. The optimized results of SPE-DLLME were obtained with PEP-2 column using methanol-acetonitrile (1/1, v/v) as elution solvent, dichloroethane, and acetonitrile as extractant and disperser solvent, respectively. The separation and determination were performed using reversed-phase chromatography on a cellulose chiral stationary phase, a Chiralpak IC (250 mm × 4.6 mm, 5 μm) column, under isocratic conditions at 0.6 mL min(-1) flow rate. The analytes were detected in multiple reaction monitoring (MRM) mode by triple quadrupole mass spectrometry. Isotopically labeled internal standards were used to compensate matrix interferences. The method provided enrichment factors of around 500. Under optimal conditions, the mean recoveries for all eight enantiomers from the water samples were 89.3-107.3 % with 0.9-10.3 % intra-day RSD and 2.3-8.1 % inter-day RSD at 20 and 100 ng L(-1) levels. Correlation coefficients (r (2)) ≥ 0.999 were achieved for all enantiomers within the range of 2-500 μg L(-1). The method detection and quantification limits were at very low levels, within the range of 0.67-2.29 ng L(-1) and 2.54-8.68 ng L(-1), respectively. This method was successfully applied to the determination of the concentrations and enantiomeric fractions of the targeted analytes in wastewater and river water, making it applicable to the assessment of the enantiomeric fate of PPIs in the environment. Graphical Abstract Simultaneous enantioselective determination of representative proton-pump inhibitors in water samples.

  20. Simultaneous determination of three pesticide adjuvant residues in plant-derived agro-products using liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Hui; Jiang, Zejun; Cao, Xiaolin; Su, Hang; Shao, Hua; Jin, Fen; Abd El-Aty, A M; Wang, Jing

    2017-12-15

    Herein, an accurate and reliable isotope-labelled internal standard method was developed and validated for simultaneous determination of three polar pesticide adjuvants, namely 2-pyrrolidone, N-methyl-2-pyrrolidone, and N-ethyl-2-pyrrolidone in plant-derived agro-products. Matrices, including apple, cabbage, tomato, cucumber, rice, and wheat were extracted with a modified quick, easy, cheap, effective, rugged, and safe "QuEChERS" method and purified with a new clean-up sorbent (Z-Sep). A hydrophilic interaction liquid chromatography column (HILIC), exhibiting a lipophilic-hydrophilic character, was used to separate the three analytes over 10min using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Matrix effects in various matrices were evaluated and an isotope-labelled internal standard method was employed to compensate for ion enhancement/suppression effects. At three fortification levels (2.0, 5.0, and 20.0μg/kg), the mean recoveries ranged from 78.5 to 112.1% with relative standard deviations (RSDs)<11.0% for all tested analytes. The limits of detection (LODs) and quantification (LOQs) were 0.04-0.45 and 0.12-1.58μg/kg in various matrices, respectively. The developed experimental protocol was successfully applied to monitor different samples purchased from local markets in Beijing, China. In conclusion, the developed method exhibited both high sensitivity and satisfactory accuracy and is suitable for the simultaneous determination of the three tested pesticide adjuvant residues in agro-products of plant origin. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of four aflatoxins and ochratoxin A in ginger after inoculation with fungi by ultra-fast liquid chromatography-tandem mass spectrometry.

    PubMed

    Yang, Ying; Wen, Jing; Kong, Weijun; Liu, Qiutao; Luo, Hongli; Wang, Jian; Yang, Meihua

    2016-09-01

    Aflatoxins (AFs) and ochratoxin A (OTA) have been detected frequently in food, agricultural products and traditional Chinese medicines, and their presence poses serious health and economic problems worldwide. Ginger can easily be polluted with mycotoxins. In this study, ginger samples were cultivated for 15 days after inoculation with fungi and were prepared based on ultrasound-assisted solid-liquid extraction using methanol/water followed by immunoaffinity column clean-up and analysed by ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) for AFs and OTA. The limits of detection and quantification of AFs and OTA were 0.04-0.30 µg mL(-1) and 0.125-1.0 µg mL(-1) , respectively. The recoveries were 82.0-100.2%. After 15 days' cultivation, no macroscopic mildew was found in ginger. But, the content of AFB1 expressed an increasing trend in ginger, peel [less than the limit of quantification (LOQ)] to the innermost layer (51.86 µ mL(-1) ), AFB2 was only detected in the innermost layer at the level of 0.87 µ mL(-1) . A small amount (

  2. Simultaneous determination of bisphenols and alkylphenols in water by solid phase extraction and ultra performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Shan, Xiao Mei; Shen, Deng Hui; Wang, Bing Shuang; Lu, Bei Bei; Huang, Fa Yuan

    2014-06-01

    To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0 μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. Relative standard deviations (RSDs) were between 1.26% and 3.67%. Applying this method to detect the source water of Chaohu Lake and drinking water of Hefei, six target compounds were detected in different levels. This method is simple with high sensitivity and selectivity, could be suitable for the determination of these compounds in source and drinking water. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  3. Simultaneous determination and pharmacokinetic study of Atractylenolide I, II and III in rat plasma after intragastric administration of Baizhufuling extract and Atractylodis extract by UPLC-MS/MS.

    PubMed

    Yan, Han; Sun, Yuanyuan; Zhang, Qili; Yang, Mingjing; Wang, Xiaorui; Wang, Yang; Yu, Zhiguo; Zhao, Yunli

    2015-07-01

    A simple and rapid ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the simultaneous determination of Atractylenolide I, II and III in rat plasma. Plasma samples were processed by liquid-liquid extraction with ethyl acetate, using schisandrin as internal standard (IS). Chromatographic separation was accomplished on a Thermo Hypersil GOLD C18 column (2.1mm×50mm, 1.9μm) with mobile phase consisting of acetonitrile and 0.1% formic acid-water (50:50, v/v). The detection was carried out by ESI-MS (positive ionization mode) and low-energy collision dissociation tandem mass spectrometric analyses using the multiple-reaction monitoring (MRM) scan mode. The quantification was performed using the transitions of the protonated molecule→product ion at m/z 231.0→185.1 for Atractylenolide I, at m/z 233.1→187.1 for Atractylenolide II and at m/z 249.1→231.1 for Atractylenolide III, respectively. Method validation revealed excellent linearity over investigated range together with satisfactory intra- and inter-day precision, accuracy, matrix effects and extraction recoveries. This method was successfully applied to the comparative pharmacokinetic study of Atractylenolide I, II and III in rat plasma after intragastric administration of Baizhufuling extract and Atractylodis extract. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Modifying glycyrrhetinic acid liposomes with liver-targeting ligand of galactosylated derivative: preparation and evaluations

    PubMed Central

    Cheng, Yi; Gao, Youheng; Zheng, Pinjing; Li, Chuangnan; Tong, Yidan; Li, Zhao; Luo, Wenhui; Chen, Zhao

    2017-01-01

    In this study, novel glycyrrhetinic acid (GA) liposomes modified with a liver-targeting galactosylated derivative ligand (Gal) were prepared using a film-dispersion method. To characterize the samples, particle size, zeta potential, drug loading, and encapsulation efficiency were performed. Moreover, plasma and tissues were pre-treated by liquid-liquid extraction and analyzed by high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The results showed that the mean residence times (MRTs) and the area under the curve (AUC) of GA liposomes with Gal (Gal-GA-LP), and GA liposomes (GA-LP) were higher than the GA solution (GA-S) in plasma. The tissue (liver) distribution of Gal-GA-LP was significantly different in contrast to GA-LP. The relative intake rate (Re) of Gal-GA-LP and GA-LP in the liver was 4.752 and 2.196, respectively. The peak concentration ratio (Ce) of Gal-GA-LP and GA-LP in the liver was 2.796 and 1.083, respectively. The targeting efficiency (Te) of Gal-GA-LP and GA-LP in the liver was 48.193% and 34.718%, respectively. Taken together, the results indicate that Gal-GA-LP is an ideal complex for liver-targeting, and has great potential application in the clinical treatment of hepatic diseases. Drug loading and releasing experiments also indicated that most liposomes are spherical structures and have good dispersity under physiologic conditions, which could prolong GA release efficiency in vitro. PMID:29254224

  5. Simultaneous Determination of Seven Neuroactive Steroids Associated with Depression in Rat Plasma and Brain by High Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Wang, Youqiong; Tang, Lipeng; Yin, Wei; Chen, Jiesi; Leng, Tiandong; Zheng, Xiaoke; Zhu, Wenbo; Zhang, Haipeng; Qiu, Pengxin; Yang, Xiaoxiao; Yan, Guangmei; Hu, Haiyan

    2016-01-01

    Sensitive and specific biomarkers are required for the diagnosis and treatment of depression because the existing diagnostic criteria are subjective and could produce false positives or negatives. Some endogenous neuroactive steroids that have shown either antidepressant effects or concentration changes in individuals with depression could provide potential biomarkers. In this study, a simple and specific method was developed to simultaneously determine seven endogenous neuroactive steroids in biological samples: cortisone, cortisol, dehydroepiandrosterone, estradiol, progesterone, pregnenolone, and testosterone. After liquid-liquid extraction, chromatographic separation was achieved on a C18 column with gradient elution using water-methanol at a flow rate of 300 μL min(-1). Detection and quantitation were performed by tandem mass spectrometry with atmospheric pressure chemical ionization and selected reaction monitoring. Plasma and brain neuroactive steroid levels were then determined in control rats and rats exposed to forced swimming, a classical rodent model of depression. The results showed that the plasma concentrations of testosterone, pregnenolone, and progesterone significantly increased in rats exposed to the forced swimming test. In contrast, brain homogenate levels of cortisol, estradiol, and progesterone decreased, while pregnenolone levels were elevated in this model of depression. In conclusion, a new method to quantify neuroactive steroids was successfully developed and applied to their investigation in rat plasma and brain. The findings of this study indicated that plasma testosterone, pregnenolone, and progesterone levels could provide potential biomarkers for the diagnosis and treatment of depression.

  6. Determination of Curcuminoids in Curcuma longa Linn. by UPLC/Q-TOF-MS: An Application in Turmeric Cultivation.

    PubMed

    Ashraf, Kamran; Mujeeb, Mohd; Ahmad, Altaf; Ahmad, Niyaz; Amir, Mohd

    2015-09-01

    Cucuma longa Linn. (Fam-Zingiberaceae) is a valued medicinal plant contains curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) as major bioactive constituents. Previously reported analytical methods for analysis of curcuminoids were found to suffer from low resolution, lower sensitivity and longer analytical times. In this study, a rapid, sensitive, selective high-throughput ultra high performance liquid chromatography-tandem mass spectrometry (UPLC/Q-TOF-MS) method was developed and validated for the quantification of curcuminoids with an aim to reduce analysis time and enhance efficiency. UPLC/Q-TOF-MS analysis showed large variation (1.408-5.027% w/w) of curcuminoids among different samples with respect to their occurrence of metabolite and their concentration. The results showed that Erode (south province) contains highest quantity of curcuminoids and concluded to be the superior varieties. The results obtained here could be valuable for devising strategies for cultivating this medicinal plant. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Bone protein extraction without demineralization using principles from hydroxyapatite chromatography.

    PubMed

    Cleland, Timothy P; Vashishth, Deepak

    2015-03-01

    Historically, extraction of bone proteins has relied on the use of demineralization to better retrieve proteins from the extracellular matrix; however, demineralization can be a slow process that restricts subsequent analysis of the samples. Here, we developed a novel protein extraction method that does not use demineralization but instead uses a methodology from hydroxyapatite chromatography where high concentrations of ammonium phosphate and ammonium bicarbonate are used to extract bone proteins. We report that this method has a higher yield than those with previously published small-scale extant bone extractions, with and without demineralization. Furthermore, after digestion with trypsin and subsequent high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis, we were able to detect several extracellular matrix and vascular proteins in addition to collagen I and osteocalcin. Our new method has the potential to isolate proteins within a short period (4h) and provide information about bone proteins that may be lost during demineralization or with the use of denaturing agents. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Simultaneous analysis of D-alanine, D-aspartic acid, and D-serine using chiral high-performance liquid chromatography-tandem mass spectrometry and its application to the rat plasma and tissues.

    PubMed

    Karakawa, Sachise; Shimbo, Kazutaka; Yamada, Naoyuki; Mizukoshi, Toshimi; Miyano, Hiroshi; Mita, Masashi; Lindner, Wolfgang; Hamase, Kenji

    2015-11-10

    A highly sensitive and selective chiral LC-MS/MS method for D-alanine, D-aspartic acid and D-serine has been developed using the precolumn derivatization reagents, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AccQ-Tag) or p-N,N,N-trimethylammonioanilyl N'-hydroxysuccinimidyl carbamate iodide (TAHS). The thus N-tagged enantiomers of the derivatized amino acids were nicely separated within 20min using the cinchona alkaloid-based zwittterionic ion-exchange type enantioselective column, Chiralpak ZWIX(+). The selected reaction monitoring was applied for detecting the target d-amino acids in biological matrices. By using the present chiral LC-MS/MS method, the three d-amino acids and their l-forms could be simultaneously determined in the range of 0.1-500nmol/mL. Finally, the technique was successfully applied to rat plasma and tissue samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. A rapid high-performance liquid chromatography-tandem mass spectrometry assay for unambiguous detection of different milk species employed in cheese manufacturing.

    PubMed

    Bernardi, Nadia; Benetti, Giuseppe; Haouet, Naceur M; Sergi, Manuel; Grotta, Lisa; Marchetti, Sonia; Castellani, Federica; Martino, Giuseppe

    2015-12-01

    The aim of the study was to investigate the possibility to differentiate the 4 most important species in Italian dairy industry (cow, buffalo, sheep, and goat), applying a bottom-up proteomic approach to assess the milk species involved in cheese production. Selective peptides were detected in milk to use as markers in cheese products. Trypsin-digested milk samples of cow, sheep, goat, and buffalo, analyzed by HPLC-tandem mass spectrometry provided species-specific peptides, some of them recognized by Mascot software (Matrix Science Ltd., Boston, MA) as derived from well-known species specific proteins. A multianalyte multiple reaction monitoring method, built with these specific peptides, was successfully applied to cheeses with different composition, showing high specificity in detection of species involved. Neither aging nor production method seemed to affect the response, demonstrating that chosen peptides well act as species markers for dairy products. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Phenolic compounds from Byrsonima crassifolia L. bark: phytochemical investigation and quantitative analysis by LC-ESI MS/MS.

    PubMed

    Maldini, Mariateresa; Montoro, Paola; Pizza, Cosimo

    2011-08-25

    Phytochemical investigation of the methanolic extract of Byrsonima crassifolia's bark led to the isolation of 8 known phenolic compounds 5-O-galloylquinic acid, 3-O-galloylquinic acid, 3,4-di-O-galloylquinic acid, 3,5-di-O-galloylquinic acid, 3,4,5-tri-O-galloylquinic acid, (+)-epicatechin-3-gallate along with (+)-catechin and (+)-epicatechin. Due to their biological value, in the present study, a high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, working in multiple reaction monitoring (MRM) mode, has been developed to quantify these compounds. B. crassifolia bark resulted in a rich source of phenolic compounds and particularly of galloyl derivates. The proposed analytical method is promising to be applied to other galloyl derivatives to quantify these bioactive compounds in raw material and final products. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Correlation of emotional labor and cortisol concentration in hair among female kindergarten teachers.

    PubMed

    Qi, Xingliang; Ji, Shuang; Zhang, Jing; Lu, Wanyong; Sluiter, Judith K; Deng, Huihua

    2017-01-01

    The purpose of this study was to explore whether two types of emotional labor, surface acting and deep acting, are related to hair cortisol concentration among kindergarten teachers. Surface acting and deep acting over the last month were measured with the Chinese version of the emotional labor scale in 43 kindergarten teachers. Hair samples with 1 cm in length were cut from their posterior vertex region to represent cortisol excretion over one month. Cortisol concentrations were analyzed with high-performance liquid chromatography-tandem mass spectrometry. Positive association of emotion labor with hair cortisol concentration was significant for surface acting (r = 0.34, p < 0.05) and not significant for deep acting (r = 0.14, p > 0.05). More surface acting showed to be associated stronger with stress responses or higher HPA axis activity.

  12. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    PubMed

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  13. Derivatization of beta-dicarbonyl compound with 2,4-dinitrophenylhydrazine to enhance mass spectrometric detection: application in quantitative analysis of houttuynin in human plasma.

    PubMed

    Duan, Xiaotao; Zhong, Dafang; Chen, Xiaoyan

    2008-06-01

    Houttuynin (decanoyl acetaldehyde), a beta-dicarbonyl compound, is the major antibacterial constituent in the volatile oil of Houttuynina cordata Thunb. In the present work, detection of houttuynin in human plasma based on the chemical derivatization with 2,4-dinitrophenylhydrazine (DNPH) coupled with liquid chromatography/tandem mass spectrometry was described. The primary reaction products between the beta-dicarbonyl compound and DNPH in aqueous phase were identified as heterocyclic structures, of which the mass spectrometric ionization and fragmentation behavior were characterized with the aid of high-resolution multistage mass spectral analysis. For quantification, houttuynin and internal standard (IS, benzophenone) in plasma were firstly converted to their DNPH derivatives without sample purification, then extracted from human plasma with n-hexane and detected by liquid chromatography tandem mass spectrometry performed in selected reaction monitoring (SRM) mode. This method allowed for a lower limit of quantification (LLOQ) of 1.0 ng/ml using 100-microl plasma. The validation results showed high accuracy (%bias < 2.1) and precision (%CV < 7.2) at broad linear dynamic range (1.0-5000 ng/ml). The simple and quantitative derivatization coupled with tandem mass spectrometric analysis facilitates a sensitive and robust method for the determination of plasma houttuynin in pharmacokinetic studies.

  14. Detection of levamisole exposure in cocaine users by liquid chromatography-tandem mass spectrometry.

    PubMed

    Lynch, Kara L; Dominy, Stephen S; Graf, Jonathan; Kral, Alexander H

    2011-04-01

    Levamisole, a veterinary antihelminthic, was recently recognized as an adulterant in cocaine and is known to cause severe adverse reactions in some cocaine users. Because of the health concerns involving levamisole-adulterated cocaine, we developed a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the detection of levamisole in urine. This method was used to determine the prevalence of levamisole in cocaine-positive patient samples. All cocaine-positive urine samples that were sent to the San Francisco General Hospital Clinical Laboratory were tested for levamisole for one month. For LC, an Agilent 1200 series was used with a C(18) column and a gradient of mobile phase A (0.05% formic acid) and B (acetonitrile/methanol). Detection was carried out with an Applied Biosystems QTRAP(®) LC-MS-MS. The levamisole LC-MS-MS method was linear over the range of 5-2500 ng/mL (r > 0.996). Interassay and intraassay CVs were < 6%. The lower limit of detection for levamisole was 0.5 ng/mL. Out of 949 total urine drug screens, 20% were positive for benzoylecgonine, and of those, 88% were positive for levamisole. The high prevalence of levamisole-adulterated cocaine and potential toxicity in cocaine users is a serious public health concern. These findings validate the utility of an LC-MS-MS method for the detection of levamisole.

  15. Determination of Glyphosate, Maleic Hydrazide, Fosetyl Aluminum, and Ethephon in Grapes by Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Chamkasem, Narong

    2017-08-30

    A simple high-throughput liquid chromatography/tandem mass spectrometry (LC-MS-MS) method was developed for the determination of maleic hydrazide, glyphosate, fosetyl aluminum, and ethephon in grapes using a reversed-phase column with weak anion-exchange and cation-exchange mixed mode. A 5 g test portion was shaken with 50 mM HOAc and 10 mM Na 2 EDTA in 1/3 (v/v) MeOH/H 2 O for 10 min. After centrifugation, the extract was passed through an Oasis HLB cartridge to retain suspended particulates and nonpolar interferences. The final solution was injected and directly analyzed in 17 min by LC-MS-MS. Two MS-MS transitions were monitored in the method for each target compound to achieve true positive identification. Four isotopically labeled internal standards corresponding to each analyte were used to correct for matrix suppression effects and/or instrument signal drift. The linearity of the detector response was demonstrated in the range from 10 to 1000 ng/mL for each analyte with a coefficient of determination (R 2 ) of ≥0.995. The average recovery for all analytes at 100, 500, and 2000 ng/g (n = 5) ranged from 87 to 111%, with a relative standard deviation of less than 17%. The estimated LOQs for maleic hydrazide, glyphosate, fosetyl-Al, and ethephon were 38, 19, 29, and 34 ng/g, respectively.

  16. Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry.

    PubMed

    Liang, H R; Foltz, R L; Meng, M; Bennett, P

    2003-01-01

    The phenomena of ionization suppression in electrospray ionization (ESI) and enhancement in atmospheric pressure chemical ionization (APCI) were investigated in selected-ion monitoring and selected-reaction monitoring modes for nine drugs and their corresponding stable-isotope-labeled internal standards (IS). The results showed that all investigated target drugs and their co-eluting isotope-labeled IS suppress each other's ionization responses in ESI. The factors affecting the extent of suppression in ESI were investigated, including structures and concentrations of drugs, matrix effects, and flow rate. In contrast to the ESI results, APCI caused seven of the nine investigated target drugs and their co-eluting isotope-labeled IS to enhance each other's ionization responses. The mutual ionization suppression or enhancement between drugs and their isotope-labeled IS could possibly influence assay sensitivity, reproducibility, accuracy and linearity in quantitative liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, calibration curves were linear if an appropriate IS concentration was selected for a desired calibration range to keep the response factors constant. Copyright 2003 John Wiley & Sons, Ltd.

  17. Effect of six Chinese spices on heterocyclic amine profiles in roast beef patties by ultra performance liquid chromatography-tandem mass spectrometry and principal component analysis.

    PubMed

    Zeng, Maomao; He, Zhiyong; Zheng, Zongping; Qin, Fang; Tao, Guanjun; Zhang, Shuang; Gao, Yahui; Chen, Jie

    2014-10-08

    The effects of Chinese spices on the profiles of 17 heterocyclic amines (HAs) from seven HA categories were investigated in roast beef patties using Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS) and principal component analysis. Three groups of HAs, imidazopyridines (PhIP, DMIP, and 1,5,6-TMIP), imidazoquinoxalines (MeIQx and 4,8-DiMeIQx), and β-carbolines (harman and norharman), were detected and quantified in all of the samples. The results demonstrated that the total HA and imidazopyridine profiles could clearly be affected by 1% pricklyash peel (14.1 ± 0.76 and 6.06 ± 0.32 ng/g), chilli (41.0 ± 0.01 and 23.0 ± 0.52 ng/g), and cumin (59.9 ± 2.44 and 31.1 ± 3.06 ng/g), in comparison with control values of 21.8 ± 2.40 and 14.3 ± 2.04 ng/g, respectively. The difference was only significant (p < 0.05) for cumin. The imidazoquinoxaline profile was significantly (p < 0.05) affected by 1% pricklyash peel (0.57 ± 0.05 ng/g) and cumin (2.36 ± 0.20 ng/g) compared to the control (1.16 ± 0.11 ng/g). The β-carboline profile was only markedly (p < 0.05) affected by 1% cumin (26.4 ± 0.82 ng/g) compared to the control (6.26 ± 0.26 ng/g). In general, pricklyash peel inhibited HA formation, whereas star anise, fennel, cumin, chilli, and black pepper promoted HA formation. The findings could facilitate the selection of spices in meat processing to minimize HA formation.

  18. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.

    PubMed

    Kocak, Fatma Emel; Ozturk, Bahadir; Isiklar, Ozben Ozden; Genc, Ozlem; Unlu, Ali; Altuntas, Irfan

    2015-01-01

    Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000's module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (κ) analysis. The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/MS. (κ: 0.83 for Abbott, κ: 0.93 for Roche) using kappa analysis. Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.

  19. Two complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods to study the excretion and metabolic interaction of edaravone and taurine in rats.

    PubMed

    Tang, Dao-quan; Zheng, Xiao-xiao; Li, Yin-jie; Bian, Ting-ting; Yu, Yan-yan; Du, Qian; Yang, Dong-zhi; Jiang, Shui-shi

    2014-11-01

    In this study, two independent and complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were respectively developed and validated for the determination of edaravone or taurine in rat urine, feces and bile after intravenous administration, using 3-methyl-l-p-tolyl-5-pyrazolone and sulfanilic acid as the internal standards (IS). Edaravone was separated on an Agilent Eclipse Plus C18 column (100×2.1 mm, 3.5 μm) using methanol and water (containing 5 mM ammonium formate and 0.02% formic acid) as mobile phase, while taurine was performed on a Waters Atlantis HILIC Silica column (150×2.1 mm, 3 μm) using acetonitrile and water (containing 5mM ammonium formate and 0.2% formic acid) as mobile phase. The mass analysis was performed in a Triple Quadrupole mass spectrometer via multiple reaction monitoring (MRM) with negative ionization mode. The optimized mass transition ion pairs (m/z) for quantification were 173.1→92.2 and 187.2→106.0 for edaravone and its IS, 124.1→80.0 and 172.0→80.0 for taurine and its IS, respectively. The validated methods have been successfully applied to the excretion and metabolism interaction study of edaravone and taurine in rats after independent intravenous administration and co-administration with a single dose. The results demonstrated that there were no significant alternations on the metabolism and cumulative excretion rate of edaravone and taurine, implying that the proposed combination therapy was pharmacologically viable. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Identification of Kynoxazine, a Novel Fluorescent Product of the Reaction between 3-Hydroxykynurenine and Erythrulose in the Human Lens, and Its Role in Protein Modification*

    PubMed Central

    Rakete, Stefan; Nagaraj, Ram H.

    2016-01-01

    Kynurenine pathway metabolites and ascorbate degradation products are present in human lenses. In this study, we showed that erythrulose, a major ascorbate degradation product, reacts spontaneously with 3-hydroxykynurenine to form a fluorescent product. Structural characterization of the product revealed it to be 2-amino-4-(2-hydroxy-3-(2-hydroxyethyl)-2H-benzo[b][1,4]oxazin-5-yl)-4-oxobutanoic acid, which we named kynoxazine. Unlike 3-hydroxykynurenine, 3-hydroxykynurenine glucoside and kynurenine were unable to form a kynoxazine-like compound, which suggested that the aminophenol moiety in 3-hydroxykynurenine is essential for the formation of kynoxazine. This reasoning was confirmed using a model compound, 1-(2-amino-3-hydroxyphenyl)ethan-1-one, which is an aminophenol lacking the amino acid moiety of 3-hydroxykynurenine. Ultra-performance liquid chromatography-tandem mass spectrometry analyses showed that kynoxazine is present in the human lens at levels ranging from 0 to 64 pmol/mg lens. Kynoxazine as well as erythrulose degraded under physiological conditions to generate 3-deoxythreosone, which modified and cross-linked proteins through the formation of an arginine adduct, 3-deoxythreosone-derived hydroimidazolone, and a lysine-arginine cross-linking adduct, 3-deoxythreosone-derived hydroimidazolimine cross-link. Ultra-performance liquid chromatography-tandem mass spectrometry quantification showed that 32–169 pmol/mg protein of 3-deoxythreosone-derived hydroimidazolone and 1.1–11.2 pmol/mg protein of 3-deoxythreosone-derived hydroimidazolimine cross-link occurred in aging lenses. Taken together, these results demonstrate a novel biochemical mechanism by which ascorbate oxidation and the kynurenine pathway intertwine, which could promote protein modification and cross-linking in aging human lenses. PMID:26941078

  1. Scheduled multiple reaction monitoring algorithm as a way to analyse new designer drugs combined with synthetic cannabinoids in human serum with liquid chromatography-tandem mass spectrometry.

    PubMed

    Dziadosz, Marek; Weller, Jens-Peter; Klintschar, Michael; Teske, Jörg

    2013-06-15

    Here, we describe the development and application of a liquid chromatography-tandem mass spectrometry method with positive electrospray ionisation and scheduled multiple reaction monitoring algorithm (s-MRM) to analyse synthetic cannabinoids (SC) combined with new designer drugs (NDD) in human serum. A Luna 5μm C18 (2) 100A, 150mm×2mm analytical column and a mobile phase consisted of A (H2O/methanol=95/5, v/v) and B (H2O/methanol=3/97, v/v) - both with 10mM ammonium acetate and 0.1% acetic acid (pH=3.2), were used for the separation. A binary flow pumping mode with a total flow rate of 0.400mL/min was used. A single sample extraction with 1-chlorobutane for both substance groups was performed. Acceptable linearity in the validated calibration ranges of 0.05-1ng/mL for SC and 1-50ng/mL for NDD was achieved. The limit of detection was not greater than 0.02/0.40ng/mL and the limit of quantification not greater than 0.05/0.50ng/mL for SC/NDD respectively. The presented study revealed that this method is a very effective way for sensitive SC and NDD identification in human serum and has useful application in hospitals, therapy centres and forensic psychiatric centres. S-MRM ensures a method upgrade with a smaller loss of sensitivity, precision and accuracy in comparison to traditional MRM methods. Also addition of new SC and NDD can be performed in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source.

    PubMed

    Yu, Kate; Di, Li; Kerns, Edward; Li, Susan Q; Alden, Peter; Plumb, Robert S

    2007-01-01

    We report in this paper an ultra-performance liquid chromatography/tandem mass spectrometric (UPLC(R)/MS/MS) method utilizing an ESI-APCI multimode ionization source to quantify structurally diverse analytes. Eight commercial drugs were used as test compounds. Each LC injection was completed in 1 min using a UPLC system coupled with MS/MS multiple reaction monitoring (MRM) detection. Results from three separate sets of experiments are reported. In the first set of experiments, the eight test compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes (ESI+, ESI-, APCI-, and APCI+) during an LC run. Approximately 8-10 data points were collected across each LC peak. This was insufficient for a quantitative analysis. In the second set of experiments, four compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes during an LC run. Approximately 15 data points were obtained for each LC peak. Quantification results were obtained with a limit of detection (LOD) as low as 0.01 ng/mL. For the third set of experiments, the eight test compounds were analyzed as a batch. During each LC injection, a single compound was analyzed. The mass spectrometer was detecting at a particular ionization mode during each LC injection. More than 20 data points were obtained for each LC peak. Quantification results were also obtained. This single-compound analytical method was applied to a microsomal stability test. Compared with a typical HPLC method currently used for the microsomal stability test, the injection-to-injection cycle time was reduced to 1.5 min (UPLC method) from 3.5 min (HPLC method). The microsome stability results were comparable with those obtained by traditional HPLC/MS/MS.

  3. Absolute quantification of protein NP24 in tomato fruit by liquid chromatography/tandem mass spectrometry using stable isotope-labelled tryptic peptide standard.

    PubMed

    Ippoushi, Katsunari; Sasanuma, Motoe; Oike, Hideaki; Kobori, Masuko; Maeda-Yamamoto, Mari

    2015-04-15

    Protein NP24 is a thaumatin-like protein contained in tomato (Lycopersicon esculentum Mill.). This protein is reported to be a putative tomato allergen and is listed as a food allergen in Structural Database of Allergenic Proteins (SDAP). In this research, we developed the quantitative analysis of NP24 by employing the protein absolute quantification (AQUA) technology composed of stable isotope-labelled internal standard (SIIS) peptide (GQTWVINAPR[(13)C6,(15)N4]) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). A linear relationship (r(2)>0.99) was found throughout the concentration range (2.0-500 fmol/μL). The coefficients of variation (CVs) measured on each of the five days when NP24 contained in the tomato skin was analysed did not exceed 13%. Our developed assay of NP24 will contribute to the allergological examination of tomato and its derived products. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Simultaneous Determination of Perfluorinated Compounds in Edible Oil by Gel-Permeation Chromatography Combined with Dispersive Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Yang, Lili; Jin, Fen; Zhang, Peng; Zhang, Yanxin; Wang, Jian; Shao, Hua; Jin, Maojun; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2015-09-30

    A simple analytical method was developed for the simultaneous analysis of 18 perfluorinated compounds (PFCs) in edible oil. The target compounds were extracted by acetonitrile, purified by gel permeation chromatography (GPC) and dispersive solid-phase extraction (DSPE) using graphitized carbon black (GCB) and octadecyl (C18), and analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ES-MS/MS) in negative ion mode. Recovery studies were performed at three fortification levels. The average recoveries of all target PFCs ranged from 60 to 129%, with an acceptable relative standard deviation (RSD) (1-20%, n = 3). The method detection limits (MDLs) ranged from 0.004 to 0.4 μg/kg, which was significantly improved compared with the existing liquid-liquid extraction and cleanup method. The method was successfully applied for the analysis of all target PFCs in edible oil samples collected from markets in Beijing, China, and the results revealed that C6-C10 perfluorocarboxylic acid (PFCAs) and C7 perfluorosulfonic acid PFSAs were the major PFCs detected in oil samples.

  5. Analysis of phospholipids in bio-oils and fats by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Viidanoja, Jyrki

    2015-09-15

    A new, sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method was developed for the analysis of Phospholipids (PLs) in bio-oils and fats. This analysis employs hydrophilic interaction liquid chromatography-scheduled multiple reaction monitoring (HILIC-sMRM) with a ZIC-cHILIC column. Eight PL class selective internal standards (homologs) were used for the semi-quantification of 14 PL classes for the first time. More than 400 scheduled MRMs were used for the measurement of PLs with a run time of 34min. The method's performance was evaluated for vegetable oil, animal fat and algae oil. The averaged within-run precision and between-run precision were ≤10% for all of the PL classes that had a direct homologue as an internal standard. The method accuracy was generally within 80-120% for the tested PL analytes in all three sample matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Determination of quinolone residues in infant and young children powdered milk combining solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Herrera-Herrera, Antonio V; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel A; Herrero, Miguel; Cifuentes, Alejandro

    2011-10-21

    The present work describes a method based on solid-phase extraction (SPE) and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the simultaneous determination of three quinolones (pipemidic acid, oxolinic acid and flumequine) and twelve fluoroquinolones (marbofloxacin, fleroxacin, pefloxacin, levofloxacin, norfloxacin, ciprofloxacin, enrofloxacin, danofloxacin, lomefloxacin, difloxacin, sarafloxacin, and moxifloxacin) in different infant and young children powdered milks. After suitable deproteination of the reconstituted powdered samples, a SPE procedure was developed providing recovery values higher than 84% (RSDs lower than 13%) for all the analytes, with limits of detection between 0.04 and 0.52 μg/kg. UPLC-MS/MS analyses were carried out in less than 10 min. Sixteen infant and young children powdered milk samples of different origin, type and composition bought at Spanish markets were analyzed. Residues of the selected antibiotics were not detected in any of the analyzed samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Simultaneous determination of acetylpuerarin and puerarin in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study following intravenous and oral administration.

    PubMed

    Sun, Deqing; Xue, Aiying; Wu, Jing; Zhang, Bin; Yu, Jinlong; Li, Qiang; Sun, Chao

    2015-07-15

    A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the simultaneous determination of acetylpuerarin (AP) and its major metabolite puerarin (PUE) in rat plasma using genistein as the internal standard (IS). Plasma samples were pretreated by protein precipitation with a mixture of methanol and acetonitrile. Chromatographic separation was performed on a CAPCELL PAK C18 MGШ column with a mixture of 0.1% formic acid in water and methanol (35:65, v/v) as the mobile phase. The analytes were detected using a tandem mass spectrometer in the positive ionization and multiple-reaction monitoring mode. The ion transition of m/z 669.4→627.3, 417.5→297.6 and 271.3→153.0 was utilized to quantify AP, PUE and the IS, respectively. The calibration curves showed good linearity over the plasma concentration range of 1-2000ng/mL for AP and 2.5-5000ng/mL for PUE. The intra- and inter-day precisions (RSD %) for each analyte were less than 6.91%, and the accuracies ranged from -2.17% to 2.93%. The validated LC-MS/MS method was further successfully applied to a pharmacokinetic study of AP and PUE in rats following intravenous and oral administration. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. On-line solid phase extraction using the Prospekt-2 coupled with a liquid chromatography/tandem mass spectrometer for the determination of dextromethorphan, dextrorphan and guaifenesin in human plasma.

    PubMed

    Kuhlenbeck, Debbie L; Eichold, Thomas H; Hoke, Steven H; Baker, Timothy R; Mensen, Robert; Wehmeyer, Kenneth R

    2005-01-01

    An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%

  9. Development of a hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the determination of kinsenoside, an antihyperlipidemic candidate, in rat plasma and its application to pharmacokinetic studies.

    PubMed

    Rehman, Shaheed Ur; Kim, In Sook; Choi, Min Sun; Luo, Zengwei; Yao, Guangming; Xue, Yongbo; Zhang, Yonghui; Yoo, Hye Hyun

    2016-02-20

    Kinsenoside is a major bioactive constituent isolated from Anoectochilus formosanus and is investigated as an antihyperlipidemic candidate. In this study, a rapid, sensitive, and reliable bioanalytical method was developed for the determination of kinsenoside in rat plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The plasma sample was pretreated with 1% acetic acid, followed by protein precipitation with acetonitrile:methanol (70:30). Chromatographic separation was performed on a HILIC silica column (2.1mm×100mm, 3μm). The mobile phases consisted of 0.1% acetic acid in distilled water (solvent A) and 0.1% acetic acid in acetonitrile (solvent B). A gradient program was used at a flow rate of 0.2mL/min. For mass spectrometric detection, the multiple reaction monitoring mode was used; the MRM transitions were m/z 265.2→m/z 102.9 for kinsenoside and m/z 163.3→m/z 132.1 for the internal standard (IS) nicotine in the positive ionization mode. A calibration curve was constructed in the range of 2-500ng/mL. The intra- and interday precision and accuracy were within 5%. The HILIC-MS/MS method was specific, accurate, and reproducible and was successfully applied in a pharmacokinetic study of kinsenoside in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry

    PubMed Central

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2009-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, and the other modified tyrosines were then quantified with isotopic dilution methods. MRM peaks of the modified tyrosines (DiY, NY, BrY, and DiBrY) from human urine were measured and the elution times coincided with the authentic and isotopic standards. The amounts of modified tyrosines in healthy human urine (n = 23) were 8.8 ± 0.6 (DiY), 1.4 ± 0.4 (NY), 3.8 ± 0.3 (BrY), and 0.7 ± 0.1 (DiBrY) µmol/mol of creatinine, respectively. A comparison of the modified tyrosines with urinary 8-oxo-deoxyguanosine, pentosidine, and Nε-(hexanoyl)lysine was also performed. Almost all products, except for NY, showed good correlations with each other. The amounts of the modified tyrosines (NY, BrY, and DiBrY) in the diabetic urine were higher than those in the urine from healthy people. PMID:19177191

  11. [Simultaneous determination of zeranols and chloramphenicol in foodstuffs of animal origin by combination immunoaffinity column clean-up and liquid chromatography-tandem mass spectrometry].

    PubMed

    Wang, Qing; Wang, Guomin; Xi, Cunxian; Li, Xianliang; Chen, Dongdong; Tang, Bobin; Zhang, Lei; Zhao, Hua

    2014-06-01

    A combination immunoaffinity column (IAC-CZ) clean-up and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method was successfully developed for zearalenol, beta-zearalenol and zearalenone) and chloramphenicol (CAP) in foodstuffs of animal origin. The samples (fish, liver, milk and honey) were enzymatically digested by beta-glucuronidase/sulfatase for about 16 h and then extracted with ether. The extracts were evaporated to dryness and then the residues were dissolved by 1.0 mL of 50% acetonitrile solution. After filtered and diluted with PBS buffer, the reconstituted solution were cleaned-up with a IAC-CZ and then analyzed by LC-MS/MS in multiple reaction monitoring (MRM) mode. The chromatographic separation was performed on a Shimadzu Shim-pack VP-ODS column with gradient elution by acetonitrile and 2 mmol/L ammonium acetate solution. The detection was carried out by electrospray negative ionization mass spectrometry in MRM mode. The proposed method was validated by the limit of detection (0.04-0.10 microg/kg), linearity (R2 > or = 0.999 0), average recoveries (70.9%-95.6%) and precisions (2.0% - 11.8%). The developed method is reliable, sensitive and has good applicability. The combination immunoaffinity column was proved to be an effective pretreatment technique to decrease the matrix effect, and it met the requirements of residue analysis of co-occurring zeranols and chloramphenicol.

  12. Determination of neonicotinoid pesticides residues in agricultural samples by solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Xie, Wen; Han, Chao; Qian, Yan; Ding, Huiying; Chen, Xiaomei; Xi, Junyang

    2011-07-15

    This work reports a new sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection, confirmation and quantification of six neonicotinoid pesticides (dinotefuran, thiamethoxam, clothiandin, imidacloprid, acetamiprid and thiacloprid) in agricultural samples (chestnut, shallot, ginger and tea). Activated carbon and HLB solid-phase extraction cartridges were used for cleaning up the extracts. Analysis is performed by LC-MS/MS operated in the multiple reaction monitoring (MRM) mode, acquiring two specific precursor-product ion transitions per target compound. Quantification was carried by the internal standard method with D(4)-labeled imidacloprid. The method showed excellent linearity (R(2)≥0.9991) and precision (relative standard deviation, RSD≤8.6%) for all compounds. Limits of quantification (LOQs) were 0.01 mg kg(-1) for chestnut, shallot, ginger sample and 0.02 mg kg(-1) for tea sample. The average recoveries, measured at three concentrations levels (0.01 mg kg(-1), 0.02 mg kg(-1) and 0.1 mg kg(-1) for chestnut, shallot, ginger sample, 0.02 mg kg(-1), 0.04 mg kg(-1) and 0.2 mg kg(-1) for tea sample), were in the range 82.1-108.5%. The method was satisfactorily validated for the analysis of 150 agricultural samples (chestnut, shallot, ginger and tea). Imidacloprid and acetamiprid were detected at concentration levels ranging from 0.05 to 3.6 mg kg(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  13. IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomic biomarker discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Tujin; Zhou, Jianying; Gritsenko, Marina A.

    2012-02-01

    Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up tomore » 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.« less

  14. Rapid and automated analysis of aflatoxin M1 in milk and dairy products by online solid phase extraction coupled to ultra-high-pressure-liquid-chromatography tandem mass spectrometry.

    PubMed

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca

    2016-01-08

    This study reports a fast and automated analytical procedure for the analysis of aflatoxin M1 (AFM1) in milk and dairy products. The method is based on the simultaneous protein precipitation and AFM1 extraction, by salt-induced liquid-liquid extraction (SI-LLE), followed by an online solid-phase extraction (online SPE) coupled to ultra-high-pressure-liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis to the automatic pre-concentration, clean up and sensitive and selective determination of AFM1. The main parameters affecting the extraction efficiency and accuracy of the analytical method were studied in detail. In the optimal conditions, acetonitrile and NaCl were used as extraction/denaturant solvent and salting-out agent in SI-LLE, respectively. After centrifugation, the organic phase (acetonitrile) was diluted with water (1:9 v/v) and purified (1mL) by online C18 cartridge coupled with an UHPLC column. Finally, selected reaction monitoring (SRM) acquisition mode was applied to the detection of AFM1. Validation studies were carried out on different dairy products (whole and skimmed cow milk, yogurt, goat milk, and powder infant formula), providing method quantification limits about 25 times lower than AFM1 maximum levels permitted by EU regulation 1881/2006 in milk and dairy products for direct human consumption. Recoveries (86-102%) and repeatability (RSD<3, n=6) meet the performance criteria required by EU regulation N. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. Moreover, no matrix effects were observed in the different milk and dairy products studied. The proposed method improves the performance of AFM1 analysis in milk samples as AFM1 determination is performed with a degree of accuracy higher than the conventional methods. Other advantages are the reduction of sample preparation procedure, time and cost of the analysis, enabling high sample throughput that meet the current concerns of food safety and the public health protection. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Correlation between Serum Levels of 3,3',5'-Triiodothyronine and Thyroid Hormones Measured by Liquid Chromatography-Tandem Mass Spectrometry and Immunoassay.

    PubMed

    Sakai, Hiroyuki; Nagao, Hidenori; Sakurai, Mamoru; Okumura, Takako; Nagai, Yoshiyuki; Shikuma, Junpei; Ito, Rokuro; Imazu, Tetsuya; Miwa, Takashi; Odawara, Masato

    2015-01-01

    For measuring serum 3,3',5'-triiodothyronine (rT3) levels, radioimmunoassay (RIA) has traditionally been used owing to the lack of other reliable methods; however, it has recently become difficult to perform. Meanwhile, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has recently been attracting attention as a novel alternative method in clinical chemistry. To the best of our knowledge, there are no studies to date comparing results of the quantification of human serum rT3 between LC-MS/MS and RIA. We therefore examined the feasibility of LC-MS/MS as a novel alternative method for measuring serum rT3, thyroxine (T4), and 3,5,3'-triiodothyronine (T3) levels. Assay validation was performed by LC-MS/MS using quality control samples of rT3, T4, and T3 at 4 various concentrations which were prepared from reference compounds. Serum samples of 50 outpatients in our department were quantified both by LC-MS/MS and conventional immunoassay for rT3, T4, and T3. Correlation coefficients between the 2 measurement methods were statistically analyzed respectively. Matrix effects were not observed with our method. Intra-day and inter-day precisions were less than 10.8% and 9.6% for each analyte at each quality control level, respectively. Intra-day and inter-day accuracies were between 96.2% and 110%, and between 98.3% and 108.6%, respectively. The lower limit of quantification was 0.05 ng/mL. Strong correlations were observed between the 2 measurement methods (correlation coefficient, T4: 0.976, p < 0.001; T3: 0.912, p < 0.001; rT3: 0.928, p < 0.001). Our LC-MS/MS system requires no manual cleanup operation, and the process after application of a sample is fully automated; furthermore, it was found to be highly sensitive, and superior in both precision and accuracy. The correlation between the 2 methods over a wide range of concentrations was strong. LC-MS/MS is therefore expected to become a useful tool for clinical diagnosis and research.

  16. Determination of 2-alkylcyclobutanones by combining precolumn derivatization with 1-naphthalenyl hydrazine and ultra-performance liquid chromatography with fluorescence detection.

    PubMed

    Meng, Xiangpeng; Tong, Tong; Wang, Lianrong; Liu, Hanxia; Chan, Wan

    2016-05-01

    2-Alkylcyclobutanones (2-ACBs) are uniquely formed when triglycerides-containing food products are exposed to ionizing radiation. Thus, 2-ACBs have been used as marker molecules to identify irradiated food. Most methods to determine 2-ACBs involve mass spectrometric detection after chromatographic separation. The spectrofluorometer is rarely used to determine 2-ACBs because these molecules do not fluoresce. In this study, we developed an ultra-performance liquid chromatography (UPLC) method to determine 2-ACBs. 2-ACBs were converted into fluorophores after reacting with 1-naphthalenyl hydrazine to facilitate their sensitive and selective detection using a fluorescence detector (FLD). Analysis of 2-ACBs using our developed UPLC-FLD method allows sensitive determination of 2-ACBs at a detection limit of 2 ng 2-ACBs per g of fat (30 pg/injection), which is significantly lower than that of existing analytical methods. After validation for trueness and precision, the method was applied to γ-irradiated chicken samples to determine their 2-ACB content. Comparative studies employing liquid chromatography-tandem mass spectrometric method revealed no systematic difference between the two methods, thereby demonstrating that the proposed UPLC-FLD method can be suitably used to determine 2-ACBs in irradiated foodstuffs. Graphical Abstract Determination of radiation-induced food-borne 2-dodecylcyclobutanone and 2-tetradecylcyclobutanone by combining 1-naphthalenyl hydrazine derivatization and ultra-performance liquid chromatography with fluorescence detection.

  17. Chemical Contaminants in Raw and Pasteurized Human Milk.

    PubMed

    Hartle, Jennifer C; Cohen, Ronald S; Sakamoto, Pauline; Barr, Dana Boyd; Carmichael, Suzan L

    2018-05-01

    Environmental contaminants ranging from legacy chemicals like p,p'-dichlorodiphenyltrichloroethane (DDT) to emerging chemicals like phthalates are ubiquitous. Research aims/questions: This research aims to examine the presence and co-occurrence of contaminants in human milk and effects of pasteurization on human milk chemical contaminants. We analyzed human milk donated by 21 women to a milk bank for 23 chemicals, including the persistent organic pollutants (POPs) polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), dichlorodiphenyltrichloroethane (DDT), and dichlorodiphenyldichloroethylene (DDE) isomers that are known to sequester in adipose tissue, along with the current-use and nonpersistent pesticides chlorpyrifos and permethrin, phthalates, and bisphenol A (BPA). Human milk was analyzed raw and pasteurized for these chemicals using gas chromatography-tandem mass spectrometry for the POPs and high-performance liquid chromatography-tandem mass spectrometry for non-POPs. Within the different chemical classes, PBDE47, PCB153, ppDDE, and MEHHP (phthalate metabolite) had the highest median concentrations and were observed in all samples. We also observed chlorpyrifos and BPA in all samples and permethrin in 90% of the samples tested. Only two chemicals, chlorpyrifos and permethrin, were susceptible to substantial degradation from pasteurization, a standard method for processing donated human milk. We detected 19 of 23 chemicals in all of our prepasteurized milk and 18 of 23 chemicals in all of our pasteurized milk. Pasteurization did not affect the presence of most of the chemicals. Future research should continue to explore human milk for potential chemical contamination and as a means to surveil exposures among women and children.

  18. Nitro-fatty acid metabolome: saturation, desaturation, beta-oxidation, and protein adduction.

    PubMed

    Rudolph, Volker; Schopfer, Francisco J; Khoo, Nicholas K H; Rudolph, Tanja K; Cole, Marsha P; Woodcock, Steven R; Bonacci, Gustavo; Groeger, Alison L; Golin-Bisello, Franca; Chen, Chen-Shan; Baker, Paul R S; Freeman, Bruce A

    2009-01-16

    Nitrated derivatives of fatty acids (NO2-FA) are pluripotent cell-signaling mediators that display anti-inflammatory properties. Current understanding of NO2-FA signal transduction lacks insight into how or if NO2-FA are modified or metabolized upon formation or administration in vivo. Here the disposition and metabolism of nitro-9-cis-octadecenoic (18:1-NO2) acid was investigated in plasma and liver after intravenous injection in mice. High performance liquid chromatography-tandem mass spectrometry analysis showed that no 18:1-NO2 or metabolites were detected under basal conditions, whereas administered 18:1-NO2 is rapidly adducted to plasma thiol-containing proteins and glutathione. NO2-FA are also metabolized via beta-oxidation, with high performance liquid chromatography-tandem mass spectrometry analysis of liver lipid extracts of treated mice revealing nitro-7-cis-hexadecenoic acid, nitro-5-cis-tetradecenoic acid, and nitro-3-cis-dodecenoic acid and corresponding coenzyme A derivatives of 18:1-NO2 as metabolites. Additionally, a significant proportion of 18:1-NO2 and its metabolites are converted to nitroalkane derivatives by saturation of the double bond, and to a lesser extent are desaturated to diene derivatives. There was no evidence of the formation of nitrohydroxyl or conjugated ketone derivatives in organs of interest, metabolites expected upon 18:1-NO2 hydration or nitric oxide (*NO) release. Plasma samples from treated mice had significant extents of protein-adducted 18:1-NO2 detected by exchange to added beta-mercaptoethanol. This, coupled with the observation of 18:1-NO2 release from glutathione-18:1-NO2 adducts, supports that reversible and exchangeable NO2-FA-thiol adducts occur under biological conditions. After administration of [3H]18:1-NO2, 64% of net radiolabel was recovered 90 min later in plasma (0.2%), liver (18%), kidney (2%), adipose tissue (2%), muscle (31%), urine (6%), and other tissue compartments, and may include metabolites not yet identified. In aggregate, these findings show that electrophilic FA nitroalkene derivatives (a) acquire an extended half-life by undergoing reversible and exchangeable electrophilic reactions with nucleophilic targets and (b) are metabolized predominantly via saturation of the double bond and beta-oxidation reactions that terminate at the site of acyl-chain nitration.

  19. Nitro-fatty Acid Metabolome: Saturation, Desaturation, β-Oxidation, and Protein Adduction*

    PubMed Central

    Rudolph, Volker; Schopfer, Francisco J.; Khoo, Nicholas K. H.; Rudolph, Tanja K.; Cole, Marsha P.; Woodcock, Steven R.; Bonacci, Gustavo; Groeger, Alison L.; Golin-Bisello, Franca; Chen, Chen-Shan; Baker, Paul R. S.; Freeman, Bruce A.

    2009-01-01

    Nitrated derivatives of fatty acids (NO2-FA) are pluripotent cell-signaling mediators that display anti-inflammatory properties. Current understanding of NO2-FA signal transduction lacks insight into how or if NO2-FA are modified or metabolized upon formation or administration in vivo. Here the disposition and metabolism of nitro-9-cis-octadecenoic (18:1-NO2) acid was investigated in plasma and liver after intravenous injection in mice. High performance liquid chromatography-tandem mass spectrometry analysis showed that no 18:1-NO2 or metabolites were detected under basal conditions, whereas administered 18:1-NO2 is rapidly adducted to plasma thiol-containing proteins and glutathione. NO2-FA are also metabolized via β-oxidation, with high performance liquid chromatography-tandem mass spectrometry analysis of liver lipid extracts of treated mice revealing nitro-7-cis-hexadecenoic acid, nitro-5-cis-tetradecenoic acid, and nitro-3-cis-dodecenoic acid and corresponding coenzyme A derivatives of 18:1-NO2 as metabolites. Additionally, a significant proportion of 18:1-NO2 and its metabolites are converted to nitroalkane derivatives by saturation of the double bond, and to a lesser extent are desaturated to diene derivatives. There was no evidence of the formation of nitrohydroxyl or conjugated ketone derivatives in organs of interest, metabolites expected upon 18:1-NO2 hydration or nitric oxide (•NO) release. Plasma samples from treated mice had significant extents of protein-adducted 18:1-NO2 detected by exchange to added β-mercaptoethanol. This, coupled with the observation of 18:1-NO2 release from glutathione-18:1-NO2 adducts, supports that reversible and exchangeable NO2-FA-thiol adducts occur under biological conditions. After administration of [3H]18:1-NO2, 64% of net radiolabel was recovered 90 min later in plasma (0.2%), liver (18%), kidney (2%), adipose tissue (2%), muscle (31%), urine (6%), and other tissue compartments, and may include metabolites not yet identified. In aggregate, these findings show that electrophilic FA nitroalkene derivatives (a) acquire an extended half-life by undergoing reversible and exchangeable electrophilic reactions with nucleophilic targets and (b) are metabolized predominantly via saturation of the double bond and β-oxidation reactions that terminate at the site of acyl-chain nitration. PMID:19015269

  20. Use of high-resolution mass spectrometry to investigate a metabolite interference during liquid chromatography/tandem mass spectrometric quantification of a small molecule in toxicokinetic study samples.

    PubMed

    Furlong, Michael; Bessire, Andrew; Song, Wei; Huntington, Christopher; Groeber, Elizabeth

    2010-07-15

    During routine liquid chromatography/tandem mass spectrometric (LC/MS/MS) bioanalysis of a small molecule analyte in rat serum samples from a toxicokinetic study, an unexpected interfering peak was observed in the extracted ion chromatogram of the internal standard. No interfering peaks were observed in the extracted ion chromatogram of the analyte. The dose-dependent peak area response and peak area response versus time profiles of the interfering peak suggested that it might have been related to a metabolite of the dosed compound. Further investigation using high-resolution mass spectrometry led to unequivocal identification of the interfering peak as an N-desmethyl metabolite of the parent analyte. High-resolution mass spectrometry (HRMS) was also used to demonstrate that the interfering response of the metabolite in the multiple reaction monitoring (MRM) channel of the internal standard was due to an isobaric relationship between the (13)C-isotope of the metabolite and the internal standard (i.e., common precursor ion mass), coupled with a metabolite product ion with identical mass to the product ion used in the MRM transition of the internal standard. These results emphasize (1) the need to carefully evaluate internal standard candidates with regard to potential interferences from metabolites during LC/MS/MS method development, validation and bioanalysis of small molecule analytes in biological matrices; (2) the value of HRMS as a tool to investigate unexpected interferences encountered during LC/MS/MS analysis of small molecules in biological matrices; and (3) the potential for interference regardless of choice of IS and therefore the importance of conducting assay robustness on incurred in vitro or in vivo study samples. Copyright 2010 John Wiley & Sons, Ltd.

  1. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    PubMed

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Ruminal bioremediation of the high energy melting explosive (HMX) by sheep microorganisms.

    PubMed

    Eaton, Hillary L; Murty, Lia D; Duringer, Jennifer M; Craig, A Morrie

    2014-01-01

    The ability of ruminal microorganisms to degrade octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (high melting explosive, HMX) as consortia from whole rumen fluid (WRF), and individually as 23 commercially available ruminal strains, was compared under anaerobic conditions. Compound degradation was monitored by high-performance liquid chromatography, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) for delineation of the metabolic pathway. In WRF, 30 μM HMX was degraded to 5 μM HMX within 24 h. Metabolites consistent with m/z 149, 193 and 229 were present throughout the incubation period. We propose that peaks with an m/z of 149 and 193 are arrived at through reduction of HMX to nitroso or hydroxylamino intermediates, then direct enzymatic ring cleavage to produce these HMX derivatives. Possible structures of m/z 229 are still being investigated and require further LC-MS/MS analysis. None of the 23 ruminal strains tested were able to degrade HMX as a pure culture when grown in either a low carbon or low nitrogen basal medium over 120 h. We conclude that microorganisms from the rumen, while sometimes capable as individuals in the bioremediation of other explosives, excel as a community in the case of HMX breakdown. © 2013 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  3. Novel amphiphilic polymeric ionic liquid-solid phase micro-extraction membrane for the preconcentration of aniline as degradation product of azo dye Orange G under sonication by liquid chromatography-tandem mass spectrometry.

    PubMed

    Cai, Mei-Qiang; Wei, Xiao-Qing; Du, Chun-Hui; Ma, Xu-Ming; Jin, Mi-Cong

    2014-07-04

    A novel amphiphilic polymeric ionic liquid membrane containing a hydrophilic bromide anion and a hydrophobic carbonyl group was synthesized in dimethylformamide (DMF) systems using the ionic liquid 1-butyl-3-vinylimidazolium bromide (BVImBr) and the methylmethacrylate (MMA) as monomers. The prepared amphiphilic ploy-methylmethacrylate-1-butyl-3-vinylimidazolium bromide (MMA-BVImBr) was characterized by a scanning electron microscope and an infrared spectrum instrument. The results of solid-phase micro-extraction membrane (SPMM) experiments showed that the adsorption capacity of membrane was about 0.76μgμg(-1) for aniline. Based on this, a sensitive method for the determination of trace aniline, as a degradation product of azo dye Orange G under sonication, was developed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The calibration curve showed a good linearity ranging from 0.5 to 10.0μgL(-1) with a correlation coefficient value of 0.9998. The limit of quantification was 0.5μgL(-1). The recoveries ranged from 90.6% to 96.1%. The intra- and inter-day relative standard deviations were less than 8.3% and 10.9%. The developed SPMM-LC-MS/MS method was used successfully for preconcentration of trace aniline produced during the sonication of Orange G solution. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Multiresidue analysis of endocrine-disrupting compounds and perfluorinated sulfates and carboxylic acids in sediments by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Cavaliere, Chiara; Capriotti, Anna Laura; Ferraris, Francesca; Foglia, Patrizia; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2016-03-18

    A multiresidue analytical method for the determination of 11 perfluorinated compounds and 22 endocrine-disrupting compounds (ECDs) including 13 natural and synthetic estrogens (free and conjugated forms), 2 alkylphenols, 1 plasticiser, 2 UV-filters, 1 antimicrobial, and 2 organophosphorus compounds in sediments has been developed. Ultrasound-assisted extraction followed by solid phase extraction (SPE) with graphitized carbon black (GCB) cartridge as clean-up step were used. The extraction process yield was optimized in terms of solvent composition. Then, a 3(2) experimental design was used to optimize solvent volume and sonication time by response surface methodology, which simplifies the optimization procedure. The final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The optimized sample preparation method is simple and robust, and allows recovery of ECDs belonging to different classes in a complex matrix such as sediment. The use of GCB for SPE allowed to obtain with a single clean-up procedure excellent recoveries ranging between 75 and 110% (relative standard deviation <16%). The developed methodology has been successfully applied to the analysis of ECDs in sediments from different rivers and lakes of the Lazio Region (Italy). These analyses have shown the ubiquitous presence of chloro-substituted organophosphorus flame retardants and bisphenol A, while other analyzed compounds were occasionally found at concentration between the limit of detection and quantification. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Quantitative analysis of flavonoids, alkaloids and saponins of Banxia Xiexin decoction using ultra-high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Wang, Ying; Xu, Ranchi; Xiao, Juan; Zhang, Jian; Wang, Xinhong; An, Rui; Ma, Yueming

    2014-01-01

    Banxia Xiexin decoction (BXD) is an effective Chinese Medicinal Prescription in treating gastroenteritis diseases. In this study an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to separate and determine 18 major active ingredients of BXD in order to guarantee quality. The separation of ten flavonoids, four alkaloids and four saponins was accomplished on an Acquity BEH C18 (2.1mm×100mm, 1.7μm) column using gradient elution with 0.1% (v/v) formic acid water (A) and 0.1% (v/v) formic acid in methanol (B). All the analytes were detected in positive electrospray ionization tandem mass spectrometry by selective reaction monitoring (SRM) mode. A good linear regression relationship for each analyte was obtained over the range from 2.41-438ng/ml to 20.75-4150ng/ml. The precision was evaluated by intra- and inter-day assays with relative standard deviation (RSD) less than 7.7%. The recovery measured at three concentration levels varied from 92.4% to 107.8%. The method sensitivity expressed as LOQ was typically 0.97-4.15ng/ml. The assay was successfully applied for determination of the 18 bioactive compounds in BXD. The results indicated that the new UPLC-MS/MS method was rapid and accurate, and could be reliably utilized as a quality control method for BXD. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. The O-methyltransferase PMT2 mediates methylation of pinosylvin in Scots pine.

    PubMed

    Paasela, Tanja; Lim, Kean-Jin; Pietiäinen, Milla; Teeri, Teemu H

    2017-06-01

    Heartwood extractives are important determinants of the natural durability of pine heartwood. The most important phenolic compounds affecting durability are the stilbenes pinosylvin and its monomethylether, which in addition have important functions as phytoalexins in active defense. A substantial portion of the synthesized pinosylvin is 3-methoxylated but the O-methyltransferase responsible for this modification has not been correctly identified. We studied the expression of the stilbene pathway during heartwood development as well as in response to wounding of xylem and UV-C treatment of needles. We isolated and enzymatically characterized a novel O-methyltransferase, PMT2. The methylated product was verified as pinosylvin monomethylether using ultra performance liquid chromatography-tandem mass spectrometry and high performance liquid chromatography analyses. The PMT2 enzyme was highly specific for stilbenes as substrate, in contrast to caffeoyl-CoA O-methyltransferase (CCoAOMT) and PMT1 that were multifunctional. Expression profile and multifunctional activity of CCoAOMT suggest that it might have additional roles outside lignin biosynthesis. PMT1 is not involved in the stilbene pathway and its biological function remains an open question. We isolated a new specific O-methyltransferase responsible for 3-methoxylation of pinosylvin. Expression of PMT2 closely follows stilbene biosynthesis during developmental and stress induction. We propose that PMT2 is responsible for pinosylvin methylation in Scots pine (Pinus sylvestris), instead of the previously characterized methyltransferase, PMT1. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  7. Development of a robust, sensitive and selective liquid chromatography-tandem mass spectrometry assay for the quantification of the novel macrocyclic peptide kappa opioid receptor antagonist [D-Trp]CJ-15,208 in plasma and application to an initial pharmacokinetic study.

    PubMed

    Khaliq, Tanvir; Williams, Todd D; Senadheera, Sanjeewa N; Aldrich, Jane V

    2016-08-15

    Selective kappa opioid receptor (KOR) antagonists may have therapeutic potential as treatments for substance abuse and mood disorders. Since [D-Trp]CJ-15,208 (cyclo[Phe-d-Pro-Phe-d-Trp]) is a novel potent KOR antagonist in vivo, it is imperative to evaluate its pharmacokinetic properties to assist the development of analogs as potential therapeutic agents, necessitating the development and validation of a quantitative method for determining its plasma levels. A method for quantifying [D-Trp]CJ-15,208 was developed employing high performance liquid chromatography-tandem mass spectrometry in mouse plasma. Sample preparation was accomplished through a simple one-step protein precipitation method with acetonitrile, and [D-Trp]CJ-15,208 analyzed following HPLC separation on a Hypersil BDS C8 column. Multiple reaction monitoring (MRM), based on the transitions m/z 578.1→217.1 and 245.0, was specific for [D-Trp]CJ-15,208, and MRM based on the transition m/z 566.2→232.9 was specific for the internal standard without interference from endogenous substances in blank mouse plasma. The assay was linear over the concentration range 0.5-500ng/mL with a mean r(2)=0.9987. The mean inter-day accuracy and precision for all calibration standards were 93-118% and 8.9%, respectively. The absolute recoveries were 85±6% and 81±9% for [D-Trp]CJ-15,208 and the internal standard, respectively. The analytical method had excellent sensitivity with a lower limit of quantification of 0.5ng/mL using a sample volume of 20μL. The method was successfully applied to an initial pharmacokinetic study of [D-Trp]CJ-15,208 following intravenous administration to mice. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Development of a robust, sensitive and selective liquid chromatography-tandem mass spectrometry assay for the quantification of the novel macrocyclic peptide kappa opioid receptor antagonist [D-Trp]CJ-15,208 in plasma and application to an initial pharmacokinetic study

    PubMed Central

    Khaliq, Tanvir; Williams, Todd D.; Senadheera, Sanjeewa N.; Aldrich, Jane V.

    2016-01-01

    Selective kappa opioid receptor (KOR) antagonists may have therapeutic potential as treatments for substance abuse and mood disorders. Since [D-Trp]CJ-15,208 (cyclo[Phe-D-Pro-Phe-D-Trp]) is a novel potent KOR antagonist in vivo, it is imperative to evaluate its pharmacokinetic properties to assist the development of analogs as potential therapeutic agents, necessitating the development and validation of a quantitative method for determining its plasma levels. A method for quantifying [D-Trp]CJ-15,208 was developed employing high performance liquid chromatography-tandem mass spectrometry in mouse plasma. Sample preparation was accomplished through a simple one-step protein precipitation method with acetonitrile, and [D-Trp]CJ-15,208 analyzed following HPLC separation on a Hypersil BDS C8 column. Multiple reaction monitoring (MRM), based on the transitions m/z 578.1 → 217.1 and 245.0, was specific for [D-Trp]CJ-15,208, and MRM based on the transition m/z 566.2 → 232.9 was specific for the internal standard without interference from endogenous substances in blank mouse plasma. The assay was linear over the concentration range 0.5–500 ng/mL with a mean r2 = 0.9987. The mean inter-day accuracy and precision for all calibration standards was 93–118% and 8.9%, respectively. The absolute recoveries were 85±6% and 81±9% for [D-Trp]CJ-15,208 and the internal standard, respectively. The analytical method had excellent sensitivity with a lower limit of quantification of 0.5 ng/mL using a sample volume of 20 μL. The method was successfully applied to an initial pharmacokinetic study of [D-Trp]CJ-15,208 following intravenous administration to mice. PMID:27318293

  9. Fast quantification of short chain fatty acids and ketone bodies by liquid chromatography-tandem mass spectrometry after facile derivatization coupled with liquid-liquid extraction.

    PubMed

    Zeng, Mingfei; Cao, Huachuan

    2018-04-15

    Short chain fatty acids (SCFA) and ketone bodies recently emerged as important physiological relevant metabolites because of their association with microbiota, immunology, obesity and other metabolic states. They were commonly analyzed by GC-MS with long run time and laborious sample preparation. In this study we developed a novel LC-MS/MS method using fast derivatization coupled with liquid-liquid extraction to detect SCFA and ketone bodies in plasma and feces. Several different derivatization reagents were evaluated to compare the efficiency, the sensitivity and chromatographic separation of structural isomers. O‑benzylhydroxylamine was selected for its superior overall performance in reaction time and isomeric separation that allowed the measurement of each SCFAs and ketone bodies free from interferences. The derivatization procedure is facile and reproducible in aqueous-organic medium, which abolished the evaporation procedure hampering the analysis of volatile short chain acids. Enhancement in sensitivity remarkably improved the detection limit of SCFA and ketone bodies to sub-fmol level. This novel method was applied to quantify these metabolites in fecal and plasma samples from lean and DIO mouse. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Analysis of thyroid hormones in gland and serum using liquid chromatography-tandem mass spectrometry

    EPA Science Inventory

    Thyroid hormones (THs), which are critical for growth and development in all vertebrates, can be impacted through chemical perturbation of the hypothalamic-pituitary-thyroid (HPT)-axis. Amphibian and mammalian models are being used to address this research priority within US EPA...

  11. Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2014-06-10

    Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. A novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) based bioanalytical method for quantification of ethyl esters of Eicosapentaenoic acid (EPA) and Docosahexaenoic acid (DHA) and its application in pharmacokinetic study.

    PubMed

    Viswanathan, Sekarbabu; Verma, P R P; Ganesan, Muniyandithevar; Manivannan, Jeganathan

    2017-07-15

    Omega-3 fatty acids are clinically useful and the two marine omega-3 fatty acids eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are prevalent in fish and fish oils. Omega-3 fatty acid formulations should undergo a rigorous regulatory step in order to obtain United States Food and Drug Administration (USFDA) approval as prescription drug. In connection with that, despite quantifying EPA and DHA fatty acids, there is a need for quantifying the level of ethyl esters of them in biological samples. In this study, we make use of reverse phase high performance liquid chromatography coupled with mass spectrometry (RP-HPLC-MS)technique for the method development. Here, we have developed a novel multiple reaction monitoring method along with optimized parameters for quantification of EPA and DHA as ethyl esters. Additionally, we attempted to validate the bio-analytical method by conducting the sensitivity, selectivity, precision accuracy batch, carryover test and matrix stability experiments. Furthermore, we also implemented our validated method for evaluation of pharmacokinetics of omega fatty acid ethyl ester formulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Investigation of pharmaceuticals in Missouri natural and drinking water using high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Chuan; Shi, Honglan; Adams, Craig D; Gamagedara, Sanjeewa; Stayton, Isaac; Timmons, Terry; Ma, Yinfa

    2011-02-01

    A comprehensive method has been developed and validated in two different water matrices for the analysis of 16 pharmaceutical compounds using solid phase extraction (SPE) of water samples, followed by liquid chromatography coupled with tandem mass spectrometry. These 16 compounds include antibiotics, hormones, analgesics, stimulants, antiepileptics, and X-ray contrast media. Method detection limits (MDLs) that were determined in both reagent water and municipal tap water ranged from 0.1 to 9.9 ng/L. Recoveries for most of the compounds were comparable to those obtained using U.S. EPA methods. Treated and untreated water samples were collected from 31 different water treatment facilities across Missouri, in both winter and summer seasons, and analyzed to assess the 16 pharmaceutical compounds. The results showed that the highest pharmaceutical concentrations in untreated water were caffeine, ibuprofen, and acetaminophen, at concentrations of 224, 77.2, and 70 ng/L, respectively. Concentrations of pharmaceuticals were generally higher during the winter months, as compared to those in the summer due, presumably, to smaller water quantities in the winter, even though pharmaceutical loadings into the receiving waters were similar for both seasons. © 2010 Elsevier Ltd. All rights reserved.

  14. Quantitative analysis of a novel HIV fusion inhibitor (sifuvirtide) in HIV infected human plasma using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Che, Jinjing; Meng, Qingfang; Chen, Zhihang; Hou, Yunan; Shan, Chengqi; Cheng, Yuanguo

    2010-03-11

    A sensitive method for measuring sifuvirtide, a novel HIV fusion inhibitor peptide drug in HIV-1(+) human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The plasma samples were treated by solvent/detergent (S/D) method to inactivate viral activity before analysis. After protein precipitation sifuvirtide was determined by LC-MS/MS. A structure analog was used as internal standard (IS). The mass spectrometer was operated in positive ion and multiple reaction monitoring mode with transitions m/z 946.3-->159.0 for sifuvirtide and 951.7-->159.2 for IS. The intra-day precision ranged from 2.74% to 7.57% with accuracy from 91.63% to 102.53%. The inter-day precision ranged from 2.65% to 3.58% and the accuracy from 95.53% to 105.28%. Stability studies showed that sifuvirtide was stable both during the assay procedure and long-term storage. The lower limit of quantitation (LLOQ) was 9.75ngml(-1). The method was used for analyzing samples from phase IIa clinical study of sifuvirtide in China. Copyright 2009 Elsevier B.V. All rights reserved.

  15. Multi-residue method for determination of 58 pesticides, pharmaceuticals and personal care products in water using solvent demulsification dispersive liquid-liquid microextraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Caldas, Sergiane Souza; Rombaldi, Caroline; Arias, Jean Lucas de Oliveira; Marube, Liziane Cardoso; Primel, Ednei Gilberto

    2016-01-01

    A rapid and efficient sample pretreatment using solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was studied for the extraction of 58 pharmaceuticals and personal care products (PPCPs) and pesticides from water samples. Type and volume of extraction and disperser solvents, pH, salt addition, amount of salt and type of demulsification solvent were evaluated. Limits of quantification (LOQ) in the range from 0.0125 to 1.25 µg L(-1) were reached, and linearity was in the range from the LOQ of each compound to 25 μg L(-1). Recoveries ranged from 60% to 120% for 84% of the compounds, with relative standard deviations lower than 29%. The proposed method demonstrated, for the first time, that sample preparation by SD-DLLME with determination by LC-MS/MS can be successfully used for the simultaneous extraction of 32 pesticides and 26 PPCPs from water samples. The entire procedure, including the extraction of 58 organic compounds from the aqueous sample solution and the breaking up of the emulsion after extraction with water, rather than with an organic solvent, was environmentally friendly. In addition, this technique was less expensive and faster than traditional techniques. Finally, the analytical method under study was successfully applied to the analysis of all 58 pesticides and PPCPs in surface water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Determination of 25-OH-PPD in rat plasma by high-performance liquid chromatography-mass spectrometry and its application in rat pharmacokinetic studies.

    PubMed

    Zhang, Xiangrong; Zhang, Dan; Xu, Jinghua; Gu, Jingkai; Zhao, Yuqing

    2007-10-15

    A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.

  17. Development and validation of a streamlined method designed to detect residues of 62 veterinary drugs in bovine kidney using ultra-high performance liquid chromatography--tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R; Geis-Asteggiante, Lucía; Schneider, Marilyn J; Dutko, Terry; Ng, Chilton; Bluhm, Louis; Mastovska, Katerina

    2012-08-01

    In the USA, the US Department of Agriculture's Food Safety and Inspection Service (FSIS) conducts the National Residue Program designed to monitor veterinary drug and other chemical residues in beef and other slaughtered food animals. Currently, FSIS uses a 7-plate bioassay in the laboratory to screen for antimicrobial drugs in bovine kidneys from those animals tested positive by inspectors in the slaughter establishments. The microbial inhibition bioassay has several limitations in terms of monitoring scope, sensitivity, selectivity, and analysis time. Ultra-high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) has many advantages over the bioassay for this application, and this study was designed to develop, evaluate, and validate a fast UHPLC-MS/MS method for antibiotics and other high-priority veterinary drugs in bovine kidney. Five existing multi-class, multi-residue methods from the literature were tested and compared, and each performed similarly. Experiments with incurred samples demonstrated that a 5-min shake of 2 g homogenized kidney with 10 ml of 4/1 (v/v) acetonitrile/water followed by simultaneous clean-up of the initial extract with 0.5 g C18 and 10 ml hexane gave a fast, simple, and effective sample preparation method for the <10 min UHPLC-MS/MS analysis. An extensive 5-day validation process demonstrated that the final method could be used to acceptably screen for 54 of the 62 drugs tested, and 50 of those met qualitative MS identification criteria. Quantification was not needed in the application, but the method gave ≥ 70% recoveries and ≤ 25% reproducibilities for 30 of the drugs. Published 2012. This article is a U.S. Government work and is in the public domain of the USA.

  18. A rapid and sensitive LC-MS/MS method for the determination of Pulsatilla saponin D in rat plasma and its application in a rat pharmacokinetic and bioavailability study.

    PubMed

    Ouyang, Hui; Guo, Yicheng; He, Mingzhen; Zhang, Jinlian; Huang, Xiaofang; Zhou, Xin; Jiang, Hongliang; Feng, Yulin; Yang, Shilin

    2015-03-01

    A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of Pulsatilla saponin D, a potential antitumor constituent isolated from Pulsatilla chinensis in rat plasma. Rat plasma samples were pretreated by protein precipitation with methanol. The method validation was performed in accordance with US Food and Drug Administration guidelines and the results met the acceptance criteria. The method was successfully applied to assess the pharmacokinetics and oral bioavailability of Pulsatilla saponin D in rats. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases.

    PubMed

    Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo

    2017-08-28

    Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.

  20. EPA Method 538: Determination of Selected Organic Contaminants in Drinking Water by Direct Aqueous Injection-Liquid Chromatography/Tandem Mass Spectrometry (DAI-LC/MS/MS)

    EPA Pesticide Factsheets

    EPA’s Selected Analytical Methods for Environmental Remediation and Recovery (SAM) lists this method for preparation and analysis of drinking water samples to detect and measure acephate, diisopropyl methylphosphonate (DIMP), methamidophos and thiofanox.

  1. Analysis of thyroid hormones in biological samples using stable isotope dilution liquid chromatography-tandem mass spectrometry

    EPA Science Inventory

    This poster presentation will describe analytical chemistry methods for measuring thyroid hormones and related precursors and metabolites in very small tissue or plasma samples. These methods are amenable to measure thyroid hormones in amphibian tadpoles or small mammals used as ...

  2. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    EPA Science Inventory

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  3. Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the quantification of lipid-related extracellular metabolites in Saccharomyces cerevisiae.

    PubMed

    Sun, Tao; Wetzel, Stephanie J; Johnson, Mitchell E; Surlow, Beth A; Patton-Vogt, Jana

    2012-05-15

    A highly sensitive hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method was developed and validated for the quantification of glycerophosphoinositol (GroPIns), glycerophosphocholine (GroPCho), glycerol 3-phosphate (GroP), inositol, and choline in the extracellular medium of Saccharomyces cerevisiae. The media samples were pretreated with a single two-phase liquid extraction. Chromatographic separation was achieved on a Waters Xbridge HILIC (150 mm × 4.6 mm, 5 μm) column under isocratic conditions using a mobile phase composed of acetonitrile/water, 70:30 (v/v) with 10mM ammonium acetate (pH adjusted to 4.5) at a flow-rate of 0.5 mL/min. Using a triple quadrupole tandem mass spectrometer, samples were detected in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curves were linear (r² ≥ 0.995) over the range of 0.5-150 nM, with the lower limit of quantitation validated at 0.5 nM for all analytes. The intra- and inter-day precision (calculated by coefficient of variation, CV%) ranged from 1.24 to 5.88% and 2.46 to 9.77%, respectively, and intra- and inter-day accuracy (calculated by relative error, RE%) was between -8.42 to 8.22% and -9.35 to 6.62%, respectively, at all quality control levels. The extracellular metabolites were stable throughout various storage stability studies. The fully validated method was successfully applied to determine the extracellular levels of phospholipid-related metabolites in S. cerevisiae. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Complete automation of solid-phase extraction with subsequent liquid chromatography-tandem mass spectrometry for the quantification of benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine, and norbenzoylecgonine in urine--application to a high-throughput urine analysis laboratory.

    PubMed

    Robandt, Paul P; Reda, Louis J; Klette, Kevin L

    2008-10-01

    A fully automated system utilizing a liquid handler and an online solid-phase extraction (SPE) device coupled with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was designed to process, detect, and quantify benzoylecgonine (BZE), meta-hydroxybenzoylecgonine (m-OH BZE), para-hydroxybenzoylecgonine (p-OH BZE), and norbenzoylecgonine (nor-BZE) metabolites in human urine. The method was linear for BZE, m-OH BZE, and p-OH BZE from 1.2 to 10,000 ng/mL with limits of detection (LOD) and quantification (LOQ) of 1.2 ng/mL. Nor-BZE was linear from 5 to 10,000 ng/mL with an LOD and LOQ of 1.2 and 5 ng/mL, respectively. The intrarun precision measured as the coefficient of variation of 10 replicates of a 100 ng/mL control was less than 2.6%, and the interrun precision for 5 replicates of the same control across 8 batches was less than 4.8% for all analytes. No assay interference was noted from controls containing cocaine, cocaethylene, and ecgonine methyl ester. Excellent data concordance (R2 > 0.994) was found for direct comparison of the automated SPE-LC-MS-MS procedure and an existing gas chromatography-MS procedure using 94 human urine samples previously determined to be positive for BZE. The automated specimen handling and SPE procedure, when compared to the traditional extraction schema, eliminates the human factors of specimen handling, processing, extraction, and derivatization, thereby reducing labor costs and rework resulting from batch handling issues, and may reduce the number of fume hoods required in the laboratory.

  5. Multi-residue analysis of 36 priority and emerging pollutants in marine echinoderms (Holothuria tubulosa) and marine sediments by solid-liquid extraction followed by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Martín, J; Zafra-Gómez, A; Hidalgo, F; Ibáñez-Yuste, A J; Alonso, E; Vilchez, J L

    2017-05-01

    Marine echinoderms are filter-feeding invertebrates widely distributed along the coasts, and which are therefore extensively exposed to anthropogenic xenobiotics. They can serve as good sentinels for monitoring a large variety of contaminants in marine ecosystems. In this context, a multi-residue analytical method has been validated and applied to Holothuria tubulosa specimens and marine sediments for the determination of 36 organic compounds, which belong to some of the most problematic groups of emerging and priority pollutants (perfluoroalkyl compounds, estrogens, parabens, benzophenones, plasticizers, surfactants, brominated flame retardants and alkylphenols). Lyophilization of samples prior to solvent extraction and clean-up of extracts with C18, followed by liquid chromatography-tandem mass spectrometry analysis, is proposed. A Box-Behnken design was used for optimization of the most influential variables affecting the extraction and clean-up steps. For validation, matrix-matched calibration and recovery assay were applied. Linearity (% r 2 ) higher than 99%, recoveries between 80% and 114% (except in LAS and NP1EO), RSD (precision) lower than 15% and limits of quantification between 0.03 and 12.5ngg -1 dry weight (d.w.) were achieved. The method was applied to nine samples of Holothuria collected along the coast of Granada (Spain), and to marine sediments around the animals. The results demonstrated high bioaccumulation of certain pollutants. A total of 25 out of the 36 studied compounds were quantified, being surfactants, alkylphenols, perfluoroalkyl compounds, triclocarban and parabens the most frequently detected. Nonylphenol was found in the highest concentration (340 and 323ngg -1 d.w. in sediment and Holothuria samples, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.

  6. High-performance liquid chromatography-tandem mass spectrometry as a reference for analysis of tacrolimus to assess two immunoassays in patients with liver and renal transplants.

    PubMed

    Salm, P; Taylor, P J; Clark, A; Balderson, G A; Grygotis, A; Norris, R L; Lynch, S V; Shaw, L M; Pond, S M

    1997-12-01

    The accuracy and imprecision of three assays used for therapeutic monitoring of tacrolimus were tested using blood-containing weighed-in amounts of the drug, an enzyme-linked immunosorbent assay (ELISA), a microparticle enzyme immunoassay (MEIA I), and a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS2) assay. Accuracy was acceptable for the HPLC-MS2 assay at all concentrations tested (< 10% deviation) and for the ELISA at 1.0 and 4.0 microg/l. Accuracy was not acceptable for the ELISA at 15.0 and 50.0 microg/l or for the MEIA I at all concentrations tested. Imprecision was acceptable for the HPLC-MS2 assay at all concentrations tested (coefficient of variation < 10%), for the ELISA at 15.0 and 50.0 microg/l, and for the MEIA I at 15.0 and 50.0 microg/l. Imprecision was not acceptable for the ELISA at 1.0 and 4.0 microg/l or for the MEIA I at 1.0 and 4.0 microg/l. This assessment with weighed-in amounts of tacrolimus verified the HPLC-MS2 assay as a reference method. The performance of the two immunoassays with HPLC-MS2 was then compared in the clinical setting using blood from patients with liver (n = 30) and renal (n = 37) transplants. In the liver transplant group (127 samples), the range of tacrolimus concentrations measured by HPLC-MS2, ELISA, and MEIA I was 1.9 to 31.8, 2.1 to 35.0, and less than 0.1 to 36.5 mg/l, respectively. In the renal transplant group (129 samples), the ranges were 1.7 to 26.1, 1.9 to 24.4, and 0.9 to 28.5 microg/l, respectively. Compared with the HPLC-MS2, the ELISA had minimal bias (0.1 to 0.2 microg/l) but unacceptable variability in values (SD > 13%). The MEIA I had unacceptable bias (1.7-1.8 microg/l) and variability (SD > 23%). These data indicated that neither the ELISA nor MEIA I is interchangeable with HPLC-MS2. Moreover, in view of the current trend to reduce the therapeutic dose of tacrolimus, quantitative results using the MEIA I would not be obtainable during therapeutic drug monitoring in some patients in whom effective therapeutic concentrations can be less than 5.0 microg/l.

  7. Tentative identification of polar and mid-polar compounds in extracts from wine lees by liquid chromatography-tandem mass spectrometry in high-resolution mode.

    PubMed

    Delgado de la Torre, M P; Priego-Capote, F; Luque de Castro, M D

    2015-06-01

    Sustainable agriculture has a pending goal in the revalorization of agrofood residues. Wine lees are an abundant residue in the oenological industry. This residue, so far, has been used to obtain tartaric acid or pigments but not for being qualitatively characterized as a source of polar and mid-polar compounds such as flavonoids, phenols and essential amino acids. Lees extracts from 11 Spanish wineries have been analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in high resolution mode. The high-resolution power of LC-MS/MS has led to the tentative identification of the most representative compounds present in wine lees, comprising primary amino acids, anthocyans, flavanols, flavonols, flavones and non-flavonoid phenolic compounds, among others. Attending to the profile and content of polar and mid-polar compounds in wine lees, this study underlines the potential of wine lees as an exploitable source to isolate interesting compounds. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Validation of an automated solid-phase extraction method for the analysis of 23 opioids, cocaine, and metabolites in urine with ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ramírez Fernández, María del Mar; Van Durme, Filip; Wille, Sarah M R; di Fazio, Vincent; Kummer, Natalie; Samyn, Nele

    2014-06-01

    The aim of this work was to automate a sample preparation procedure extracting morphine, hydromorphone, oxymorphone, norcodeine, codeine, dihydrocodeine, oxycodone, 6-monoacetyl-morphine, hydrocodone, ethylmorphine, benzoylecgonine, cocaine, cocaethylene, tramadol, meperidine, pentazocine, fentanyl, norfentanyl, buprenorphine, norbuprenorphine, propoxyphene, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine from urine samples. Samples were extracted by solid-phase extraction (SPE) with cation exchange cartridges using a TECAN Freedom Evo 100 base robotic system, including a hydrolysis step previous extraction when required. Block modules were carefully selected in order to use the same consumable material as in manual procedures to reduce cost and/or manual sample transfers. Moreover, the present configuration included pressure monitoring pipetting increasing pipetting accuracy and detecting sampling errors. The compounds were then separated in a chromatographic run of 9 min using a BEH Phenyl analytical column on a ultra-performance liquid chromatography-tandem mass spectrometry system. Optimization of the SPE was performed with different wash conditions and elution solvents. Intra- and inter-day relative standard deviations (RSDs) were within ±15% and bias was within ±15% for most of the compounds. Recovery was >69% (RSD < 11%) and matrix effects ranged from 1 to 26% when compensated with the internal standard. The limits of quantification ranged from 3 to 25 ng/mL depending on the compound. No cross-contamination in the automated SPE system was observed. The extracted samples were stable for 72 h in the autosampler (4°C). This method was applied to authentic samples (from forensic and toxicology cases) and to proficiency testing schemes containing cocaine, heroin, buprenorphine and methadone, offering fast and reliable results. Automation resulted in improved precision and accuracy, and a minimum operator intervention, leading to safer sample handling and less time-consuming procedures.

  9. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    PubMed

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was <5%. Fujirebio 25(OH)D assay showed the highest correlation among the assays tested with the LC-MS/MS method (R=0.986). The mean relative bias obtained was -15.6% (Fujirebio), -12.7% (Beckman), -2.1% (Abbott) and 9.7% (Roche) as compared to LC-MS/MS. Comparison with the Labquality certified reference serum panel yielded a mean bias of -11.8% (Fujirebio), -14.1% (Beckman), 4.4% (Abbott) and 3.2% (Roche), respectively. Compared to LC-MS/MS, the sensitivity of different methods in detecting vitamin D insufficiency (<50 nmol/L) varied from 100% for the Fujirebio assay to 72.7% for Roche, and specificity ranged from 94.4% for Roche to 87.6% for Beckman. The Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  10. Performance Metrics for Liquid Chromatography-Tandem Mass Spectrometry Systems in Proteomics Analyses*

    PubMed Central

    Rudnick, Paul A.; Clauser, Karl R.; Kilpatrick, Lisa E.; Tchekhovskoi, Dmitrii V.; Neta, Pedatsur; Blonder, Nikša; Billheimer, Dean D.; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Ham, Amy-Joan L.; Jaffe, Jacob D.; Kinsinger, Christopher R.; Mesri, Mehdi; Neubert, Thomas A.; Schilling, Birgit; Tabb, David L.; Tegeler, Tony J.; Vega-Montoto, Lorenzo; Variyath, Asokan Mulayath; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Paulovich, Amanda G.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Tempst, Paul; Liebler, Daniel C.; Stein, Stephen E.

    2010-01-01

    A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications. PMID:19837981

  11. Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction.

    PubMed

    Wang, Perry G; Wei, Jack S; Kim, Grace; Chang, Min; El-Shourbagy, Tawakol

    2006-10-20

    Kaletra is an important antiretroviral drug, which has been developed by Abbott Laboratories. It is composed of lopinavir (low-pin-a-veer) and ritonavir (ri-toe-na-veer). Both have been proved to be human immunodeficiency virus (HIV) protease inhibitors and have substantially reduced the morbidity and mortality associated with HIV-1 infection. We have developed and validated an assay, using liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry (LC/MS/MS), for the routine quantification of lopinavir and ritonavir in human plasma, in which lopinavir and ritonavir can be simultaneously analyzed with high throughput. The sample preparation consisted of liquid-liquid extraction with a mixture of hexane: ethyl acetate (1:1, v/v), using 100 microL of plasma. Chromatographic separation was performed on a Waters Symmetry C(18) column (150 mm x 3.9 mm, particle size 5 microm) with reverse-phase isocratic using mobile phase of 70:30 (v/v) acetonitrile: 2 mM ammonium acetate aqueous solution containing 0.01% formic acid (v/v) at a flow rate of 1.0 mL/min. A Waters symmetry C(18) guard column (20 mm x 3.9 mm, particle size 5 microm) was connected prior to the analytical column, and a guard column back wash was performed to reduce the analytical column contamination using a mixture of tetrahydrofuran (THF), methanol and water (45:45:10, v/v/v). The analytical run was 4 min. The use of a 96-well plate autosampler allowed a batch size up to 73 study samples. A triple-quadrupole mass spectrometer was operated in a positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over the concentration ranges of 19-5,300 ng/mL for lopinavir and 11-3,100 ng/mL for ritonavir. A-86093 was used as an internal standard (I.S.). The relative standard deviation (RSD) were <6% for both lopinavir and ritonavir. Mean accuracies were between the designed limits (+/-15%). The robust and rapid LC/MS/MS assay has been successfully applied for routine assay to support bioavailability, bioequivalence, and pharmacokinetics studies.

  12. Occurrence of pharmaceuticals and personal care products in fish: results of a national pilot study in the United States.

    PubMed

    Ramirez, Alejandro J; Brain, Richard A; Usenko, Sascha; Mottaleb, Mohammad A; O'Donnell, John G; Stahl, Leanne L; Wathen, John B; Snyder, Blaine D; Pitt, Jennifer L; Perez-Hurtado, Pilar; Dobbins, Laura L; Brooks, Bryan W; Chambliss, C Kevin

    2009-12-01

    Pharmaceuticals and personal care products are being increasingly reported in a variety of biological matrices, including fish tissue; however, screening studies have presently not encompassed broad geographical areas. A national pilot study was initiated in the United States to assess the accumulation of pharmaceuticals and personal care products in fish sampled from five effluent-dominated rivers that receive direct discharge from wastewater treatment facilities in Chicago, Illinois; Dallas, Texas; Orlando, Florida; Phoenix, Arizona; and West Chester, Pennsylvania, USA. Fish were also collected from the Gila River, New Mexico, USA, as a reference condition expected to be minimally impacted by anthropogenic influence. High performance liquid chromatography-tandem mass spectrometry analysis of pharmaceuticals revealed the presence of norfluoxetine, sertraline, diphenhydramine, diltiazem, and carbamazepine at nanogram-per-gram concentrations in fillet composites from effluent-dominated sampling locations; the additional presence of fluoxetine and gemfibrozil was confirmed in liver tissue. Sertraline was detected at concentrations as high as 19 and 545 ng/g in fillet and liver tissue, respectively. Gas chromatography-tandem mass spectrometry analysis of personal care products in fillet composites revealed the presence of galaxolide and tonalide at maximum concentrations of 2,100 and 290 ng/g, respectively, and trace levels of triclosan. In general, more pharmaceuticals were detected at higher concentrations and with greater frequency in liver than in fillet tissues. Higher lipid content in liver tissue could not account for this discrepancy as no significant positive correlations were found between accumulated pharmaceutical concentrations and lipid content for either tissue type from any sampling site. In contrast, accumulation of the personal care products galaxolide and tonalide was significantly related to lipid content. Results suggest that the detection of pharmaceuticals and personal care products was dependent on the degree of wastewater treatment employed.

  13. A dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry for the determination of nine bisphenols in bottled carbonated beverages.

    PubMed

    Mandrah, Kapil; Satyanarayana, G N V; Roy, Somendu Kumar

    2017-12-15

    In the present study, a method has been efficiently developed for the first time to determine nine bisphenol analogues [bisphenol A (BPA), bisphenol C (BPC), bisphenol AF (BPAF), bisphenol E (BPE), bisphenol F (BPF), bisphenol G (BPG), bisphenol M (BPM), bisphenol S (BPS), and bisphenol Z (BPZ)] together in bottled carbonated beverages (collected from the local market of Lucknow, India) using dispersive liquid-liquid microextraction process. This is based on solidification of floating organic droplet (DLLME-SFO) followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry. The process investigated parameters of DLLME-SFO (including the type of extraction and disperser solvents with their volumes, effect of pH, ionic strength, and the sample volume), factors influencing to injection port derivatization like, collision energy, injector port temperature, derivatizing reagent with sample injection volume, and type of organic solvent. BPA, BPF, BPZ, and BPS were detected in each sample; whereas, other bisphenols were also detected in some carbonated beverage samples. After optimizing the required conditions, good linearity of analytes was achieved in the range of 0.097-100ngmL -1 with coefficients of determination (R 2 )≥0.995. Intra-day and inter day precision of the method was good, with relative standard deviation (% RSD)≤10.95%. The limits of detection (LOD) and limits of quantification (LOQ) values of all bisphenols were ranged from 0.021 to 0.104ngmL -1 and 0.070 to 0.343ngmL -1 , respectively. The recovery of extraction was good (73.15-95.08%) in carbonated beverage samples and good enrichment factors (96.36-117.33) were found. Thus, the developed method of microextraction was highly precise, fast, and reproducible to determine the level of contaminants in bottled carbonated beverages. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of nine neonicotinoids in human urine using isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Quan; Wang, Ximing; Li, Zhe; Jin, Hangbiao; Lu, Zhengbiao; Yu, Chang; Huang, Yu-Fang; Zhao, Meirong

    2018-05-14

    Neonicotinoids (neonics), a class of systemic insecticides, have been frequently detected in pollen, vegetables, and fruits. Recently, an increasing concern has been aroused for human exposure to neonics. However, biological monitoring for quantifying body burden of neonics has rarely been reported. In this study, we developed an isotope-dilution ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) method to simultaneously quantify nine neonics, including acetamiprid (ACE), thiamethoxam (THIAM), imidacloprid (IMIP), clothianidin (CLO), flonicamid (FLO), thiacloprid (THIAC), dinotefuran (DIN), nitenpyram (NIT), and imidaclothiz (IMIT) in urine. The limits of quantification were 0.1 μg/L for ACE, FLO, DIN, NIT and IMIT, and 0.2 μg/L for THIAM, IMIP, CLO, and THIAC. The overall recoveries were 80.8-103%, 81.5-91.7% and 83.0-92.3% for QA/QC samples fortifying at 1, 25, and 100 μg/L levels, respectively. UPLC/MS/MS method was used to analyze urine samples obtained from 10 children in Hangzhou, China. The detection frequencies were 80% for ACE and IMIP, 70% for THIAM and CLO, 20% for DIN and IMIT and 10% for THIAC. FLO and NIT were not detected in those urine samples. The data provided here will be helpful for conducting biological monitoring of neonics exposure in the future. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Simultaneous determination of five free and total flavonoids in rat plasma by ultra HPLC-MS/MS and its application to a comparative pharmacokinetic study in normal and hyperlipidemic rats.

    PubMed

    Wang, Xiaofan; Zhao, Xu; Gu, Liqiang; Lv, Chunxiao; He, Bosai; Liu, Zhenzhen; Hou, Pengyi; Bi, Kaishun; Chen, Xiaohui

    2014-03-15

    A simple and rapid ultra-high performance liquid chromatography-tandem mass spectrometry (uHPLC-MS/MS) method has been developed for the simultaneous determination of five free flavonoids (amentoflavone, isorhamnetin, naringenin, kaempferol and quercetin) and their total (free and conjugated) forms, and to compare the pharmacokinetics of these active ingredients in normal and hyperlipidemic rats. The free and total forms of these flavonoids were extracted by liquid-liquid extraction with ethyl acetate. The conjugated flavonoids were deconjugated by the enzyme β-Glucuronidase and Sulfatase. Chromatographic separation was accomplished on a ZORBAX Eclipse XDB-C8 USP L7 column using gradient elution. Detection was performed on a 4000Q uHPLC-MS/MS system from AB Sciex using negative ion mode in the multiple reaction monitoring (MRM) mode. The lower limits of quantification were 2.0-5.0ng/mL for all the analytes. Intra-day and inter-day precision were less than 15% and accuracy ranged from -9.3% to 11.0%, and the mean extraction recoveries of analytes and internal standard (IS) from rat plasma were all more than 81.7%. The validated method was successfully applied to a comparative pharmacokinetic study of five free and total analytes in rat plasma. The results indicated that the absorption of five total flavonoids in hyperlipidemia group were significantly higher than those in normal group with similar concentration-time curves. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. [Determination of 27 industrial dyes in juice and wine using ultra performance liquid chromatography with electrospray ionization tandem quadrupole mass spectrometry].

    PubMed

    Zhao, Shan; Zhang, Jing; Yang, Yi; Shao, Bing

    2010-04-01

    A method for the determination of 27 industrial dyes in juice and wine has been developed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS). Acetonitrile was used as extraction solvent, and sodium chloride was added to salt out the analytes from the samples. Chromatographic separation was performed on a C18 column with the gradient elution and the mass spectrometric acquisition was carried out under the mode of multiple reaction monitoring (MRM). Twenty-four of the 27 dyes were detected under positive ionization mode using the mobile phase of acetonitrile and water containing 0.1% formic acid. The other 3 dyes were analyzed under negative ionization mode with the mobile phase of acetonitrile and water. As a result, the average recoveries of 27 dyes spiked in juice ranged from 57.0% to 117.7% with the relative standard deviations (RSDs) of 2.4%-17.7%, and the average recoveries of 27 dyes spiked in wine ranged from 40.8% to 109.4% with the RSDs of 1.6%-17.9%. The limits of quantification (LOQs) of 27 dyes spiked in juice were in the range of 0.1-50 microg/kg, and 0.2-50 microg/kg for those spiked in wine. This method can be applied to rapid detection of illegally added dyes in soft drinks due to its simplicity and high sensitivity.

  17. [Simultaneous determination of ten benzotriazole ultraviolet stabilizers in food contact plastic materials by solid phase extraction and ultra performance liquid chromatography with tandem mass spectrometry].

    PubMed

    Gou, Xinlei; Zhao, Xinying; Chi, Haitao; Gao, Xia; Zhou, Mingqiang; Liu, Weili

    2015-06-01

    A sensitive method was developed for the simultaneous determination of ten benzotriazole ultraviolet stabilizers in food contact plastic materials by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample was extracted by methanol-dichloromethane, and purified by a C18 solid-phase extraction (SPE) column. The separation was performed by using water containing 0. 1% (v/v) formic acid and methanol as the mobile phases with gradient elution at a flow rate of 0. 3 mL/min. The electrospray ionization (ESI) source in positive ion mode was used for the analysis of the ten benzotriazole ultraviolet stabilizers in multiple reaction monitoring (MRM) mode. The results showed that the standard curves were obtained with good correlation coefficients (r2 > 0.996) in their linear concentration ranges. The limits of detection (LODs, S/N = 3) for the ten benzotriazole ultraviolet stabilizers were in the range of 0.6-1.6 µg/kg. The mean recoveries for the ten benzotriazole ultraviolet stabilizers at three spiked levels (low, medium and high) were 75.2%-85.3% with relative standard deviations of 1.0%-5.7%. Ten kinds of food contact plastic materials were tested, and 2,2'-methylenebis (6-(benzotriazol-2-yl)-4-tert-octylphenol) (UV-360) was found in a sample of polyethylene (PE) material. The method is accurate, simple, rapid and feasible for the simultaneous determination of benzotriazole ultraviolet stabilizers in food plastic materials.

  18. [Analysis of sialic acid in infant formulas using ultra performance liquid chromatography-triple quadrupole mass spectrometry].

    PubMed

    Xie, Honglei; Li, Chun; Liu, Ning

    2013-08-01

    The method for analysing sialic acid in infant formulas by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been established. Sialic acid in milk was released via acid hydrolysis, and purified by an HLB solid phase extraction cartridge. The UPLC separation was performed on an ACQUITY UPLC BEH HILIC column (50 mm x 2.1 mm, 1.7 microm) utilizing a gradient elution program of acetonitrile and water (containing 0.1% formic acid) as the mobile phases at a flow rate of 0.25 mL/min. Injection volume and column temperature were set at 5 microL and 30 degrees C, respectively. The identification and quantification were achieved by using electrospray ionisation (ESI)-MS/MS in positive ion mode and multiple reaction monitoring (MRM) mode. The linear range was from 0.05 to 5.0 mg/L for sialic acid and the correlation coefficient (R(2)) was greater than 0.99. The average recoveries spiked at the four concentration levels of 0.1, 0.5, 2.5 and 5.0 mg/L ranged between 84.3% and 98.9% with the relative standard deviations from 4.9% to 8.2%. The limit of detection was 0.01 mg/L. Therefore, this method has the characteristics of simple operation, high reproducibility and sensitivity. It can be widely applied to determine the total contents of sialic acid in infant formula, cow milk and human milk.

  19. Development and validation of amitriptyline and its metabolite in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to a bioequivalence study.

    PubMed

    Bhatt, Mitesh; Shah, Sanjay

    2010-11-01

    A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic-lipophilic balance cartridges. The assay involves a simple solid-phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370-95.539 ng/mL for amitriptyline and 0.365-94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r², which was better than 0.995 for both. The intra- and inter-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.

  20. High-Risk Screening for Fabry Disease: Analysis by Tandem Mass Spectrometry of Globotriaosylceramide (Gb3 ) in Urine Collected on Filter Paper.

    PubMed

    Auray-Blais, Christiane; Lavoie, Pamela; Boutin, Michel; Abaoui, Mona

    2017-04-06

    Fabry disease is a complex, panethnic lysosomal storage disorder. It is characterized by the accumulation of glycosphingolipids in tissues, organs, the vascular endothelium, and biological fluids. The reported incidence in different populations is quite variable, ranging from 1:1400 to 1:117,000. Its complexity lies in the marked genotypic and phenotypic heterogeneity. Despite the fact that it is an X-linked disease, more than 600 mutations affect both males and females. In fact, some females may be affected as severely as males. The purpose of this protocol is to focus on the high-risk screening of patients who might have Fabry disease using a simple, rapid, non-invasive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for urinary globotriaosylceramide (Gb 3 ) analysis. Urine filter paper samples are easily collected at home by patients and sent by regular mail. This method has been successfully used for high-risk screening of patients with ophthalmologic manifestations and in an on-going study for high-risk screening of Fabry disease in patients with chronic kidney diseases. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  1. Solid phase microextraction of macrolide, trimethoprim, and sulfonamide antibiotics in wastewaters.

    PubMed

    McClure, Evelyn L; Wong, Charles S

    2007-10-26

    In this work, we optimize a solid phase microextraction (SPME) method for the simultaneous collection of antibiotics (sulfonamides, macrolides, and trimethoprim) present in wastewaters. The performance of the SPME method is compared to a solid phase extraction (SPE) method. Analytes in both cases were quantified by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with electrospray ionization. The advantages offered by SPME in this application are: decreased sample volume requirements, ease of sample processing and extraction, decreased cost, and most importantly, elimination of electrospray matrix effects. Despite having higher limits of quantification (16-1380 ng/L in influent and 35-260 ng/L in effluent), nearly all of the compounds found to be present in Edmonton Gold Bar wastewater by SPE were measurable by SPME (i.e., sulfamethoxazole, trimethoprim, erythromycin, and clarithromycin), with values similar to those obtained using the former method. Limits of quantification for the SPE method for the measured compounds were 4.7-15 ng/L and 0.86-6.1 ng/L for influent and effluent, respectively.

  2. Determination of adrenaline, noradrenaline and corticosterone in rodent blood by ion pair reversed phase UHPLC-MS/MS.

    PubMed

    Bergh, Marianne Skov-Skov; Bogen, Inger Lise; Andersen, Jannike Mørch; Øiestad, Åse Marit Leere; Berg, Thomas

    2018-01-01

    A novel ion pair reversed phase ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of the stress hormones adrenaline, noradrenaline and corticosterone in rodent blood was developed and fully validated. Separations were performed on an Acquity HSS T3 column (2.1mm i.d.×100mm, 1.8μm) with gradient elution and a runtime of 5.5min. The retention of adrenaline and noradrenaline was substantially increased by employing the ion pair reagent heptafluorobutyric acid (HFBA). Ion pair reagents are usually added to the mobile phase only, but we demonstrate for the first time that including HFBA to the sample reconstitution solvent as well, has a major impact on the chromatography of these compounds. The stability of adrenaline and corticosterone in rodent blood was investigated using the surrogate analytes adrenaline-d 3 and corticosterone-d 8 . The applicability of the described method was demonstrated by measuring the concentration of stress hormones in rodent blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Liquid chromatography-tandem mass spectrometry analysis of perfluorooctane sulfonate and perfluorooctanoic Acid in fish fillet samples.

    PubMed

    Paiano, Viviana; Fattore, Elena; Carrà, Andrea; Generoso, Caterina; Fanelli, Roberto; Bagnati, Renzo

    2012-01-01

    Perfluorooctane sulfonate (PFOS) and perfluorooctanoic (PFOA) acid are persistent contaminants which can be found in environmental and biological samples. A new and fast analytical method is described here for the analysis of these compounds in the edible part of fish samples. The method uses a simple liquid extraction by sonication, followed by a direct determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The linearity of the instrumental response was good, with average regression coefficients of 0.9971 and 0.9979 for PFOS and PFOA, respectively, and the coefficients of variation (CV) of the method ranged from 8% to 20%. Limits of detection (LOD) were 0.04 ng/g for both the analytes and recoveries were 90% for PFOS and 76% for PFOA. The method was applied to samples of homogenized fillets of wild and farmed fish from the Mediterranean Sea. Most of the samples showed little or no contamination by perfluorooctane sulfonate and perfluorooctanoic acid, and the highest concentrations detected among the fish species analyzed were, respectively, 5.96 ng/g and 1.89 ng/g. The developed analytical methodology can be used as a tool to monitor and to assess human exposure to perfluorinated compounds through sea food consumption.

  4. Lipidomic analysis for carbonyl species derived from fish oil using liquid chromatography-tandem mass spectrometry.

    PubMed

    Suh, Joon Hyuk; Niu, Yue S; Hung, Wei-Lun; Ho, Chi-Tang; Wang, Yu

    2017-06-01

    Lipid peroxidation gives rise to carbonyl species, some of which are reactive and play a role in the pathogenesis of numerous human diseases. Oils are ubiquitous sources that can be easily oxidized to generate these compounds under oxidative stress. In this present work, we developed a targeted lipidomic method for the simultaneous determination of thirty-five aldehydes and ketones derived from fish oil, the omega-3 fatty acid-rich source, by using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analytes include highly toxic reactive carbonyl species (RCS) such as acrolein, crotonaldehyde, trans-4-hydroxy-2-hexenal (HHE), trans-4-hydroxy-2-nonenal (HNE), trans-4-oxo-2-nonenal (ONE), glyoxal and methylglyoxal, all of which are promising biomarkers of lipid peroxidation. They were formed using in vitro Fe(II)-mediated oxidation, and derivatized using 2,4-dinitrophenylhydrazine (DNPH) for the feasibility of quantitative assay. Before analysis, solid phase extraction (SPE) was used to clean samples further. Uniquely different patterns of carbonyl compound generation between omega-3 and 6 fatty acids were observed using this lipidomic approach. The method developed was both validated, and successfully applied to monitor formation of carbonyl species by lipid peroxidation using ten different fish oil products. Hypotheses of correlations between the monitored dataset of analytes and their parent fatty acids were also tested using the Pearson's correlation test. Results indicate our method is a useful analytical tool for lipid peroxidation studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Evaluation of boldenone formation and related steroids transformations in veal faeces by liquid chromatography/tandem mass spectrometry.

    PubMed

    Arioli, Francesco; Gavinelli, Matteo P; Fracchiolla, Maria L; Casati, Alessio; Fidani, Marco; Ferrer, Emilia; Pompa, Giuseppe

    2008-01-01

    It is established that bovine urine can result positive for boldenone and androstadienedione in consequence of faecal contamination. The simple transfer of steroids to urine is one minor aspect of faecal contamination. A high de novo production of steroids in faeces after deposition and in faeces-contaminated urine is almost certainly due to microbial activity, although the precursor compounds and transformations leading to the presence of these illegal steroids are unclear. We developed a simple in vitro method - incubation of faecal matter suspended in 0.9% saline - to induce steroid transformations in faeces, and analyzed the products by liquid chromatography/tandem mass spectrometry, without the need for prior extraction. Norethandrolone was the internal standard. The linearity (R(2): 0.987-0.999), sensitivity (LODs: 0.3 to 1.0 ng/mL; LOQs: 1.0 to 3.0 ng/mL), precision (intra-day CVs: 2.6-8.2; inter-day CVs: 4.5-11.5) and accuracy (percentage recovery: 89-120%) were calculated for the studied steroids. Androstenedione, androstadienedione, alpha- and beta-boldenone, testosterone and epitestosterone transformations were investigated. Mutual interconversion of steroids was observed, although 17beta-hydroxy steroids had low stability compared with 17alpha-hydroxy and 17-keto steroids. The results suggest that this simple in vitro system may be an effective way of studying hormone transformations in faeces and, after analogue studies, in faeces-contaminated urine. Copyright (c) 2007 John Wiley & Sons, Ltd.

  6. A novel amino acid analysis method using derivatization of multiple functional groups followed by liquid chromatography/tandem mass spectrometry.

    PubMed

    Sakaguchi, Yohei; Kinumi, Tomoya; Yamazaki, Taichi; Takatsu, Akiko

    2015-03-21

    We have developed a novel amino acid analysis method using derivatization of multiple functional groups (amino, carboxyl, and phenolic hydroxyl groups). The amino, carboxyl, and phenolic hydroxyl groups of the amino acids were derivatized with 1-bromobutane so that the hydrophobicities and basicities of the amino acids were improved. The derivatized amino acids, including amino group-modified amino acids, could be detected with high sensitivity using liquid chromatography/tandem mass spectrometry (LC-MS/MS). In this study, 17 amino acids obtained by hydrolyzing proteins and 4 amino group-modified amino acids found in the human body (N,N-dimethylglycine, N-formyl-L-methionine, L-pyroglutamic acid, and sarcosine) were selected as target compounds. The 21 derivatized amino acids could be separated using an octadecyl-silylated silica column within 20 min and simultaneously detected. The detection limits for the 21 amino acids were 5.4-91 fmol, and the calibration curves were linear over the range of 10-100 nmol L(-1) (r(2) > 0.9984) with good repeatability. A confirmatory experiment showed that our proposed method could be applied to the determination of a protein certified reference material using the analysis of 12 amino acids combined with isotope dilution mass spectrometry. Furthermore, the proposed method was successfully applied to a stable isotope-coded derivatization method using 1-bromobutane and 1-bromobutane-4,4,4-d3 for comparative analysis of amino acids in human serum.

  7. Determination of six sulfonamide antibiotics, two metabolites and trimethoprim in wastewater by isotope dilution liquid chromatography/tandem mass spectrometry.

    PubMed

    Le-Minh, Nhat; Stuetz, Richard M; Khan, Stuart J

    2012-01-30

    A highly sensitive method for the analysis of six sulfonamide antibiotics (sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine and sulfamethoxazole), two sulfonamide metabolites (N(4)-acetyl sulfamethazine and N(4)-acetyl sulfamethoxazole) and the commonly co-applied antibiotic trimethoprim was developed for the analysis of complex wastewater samples. The method involves solid phase extraction of filtered wastewater samples followed by liquid chromatography-tandem mass spectral detection. Method detection limits were shown to be matrix-dependent but ranged between 0.2 and 0.4 ng/mL for ultrapure water, 0.4 and 0.7 ng/mL for tap water, 1.4 and 5.9 ng/mL for a laboratory-scale membrane bioreactor (MBR) mixed liquor, 0.7 and 1.7 ng/mL for biologically treated effluent and 0.5 and 1.5 ng/g dry weight for MBR activated sludge. An investigation of analytical matrix effects was undertaken, demonstrating the significant and largely unpredictable nature of signal suppression observed for variably complex matrices compared to an ultrapure water matrix. The results demonstrate the importance of accounting for such matrix effects for accurate quantitation, as done in the presented method by isotope dilution. Comprehensive validation of calibration linearity, reproducibility, extraction recovery, limits of detection and quantification are also presented. Finally, wastewater samples from a variety of treatment stages in a full-scale wastewater treatment plant were analysed to illustrate the effectiveness of the method. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry.

    PubMed

    Matysik, Silke; Liebisch, Gerhard

    2017-12-01

    A limited specificity is inherent to immunoassays for steroid hormone analysis. To improve selectivity mass spectrometric analysis of steroid hormones by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been introduced in the clinical laboratory over the past years usually with low mass resolution triple-quadrupole instruments or more recently by high resolution mass spectrometry (HR-MS). Here we introduce liquid chromatography-high resolution tandem mass spectrometry (LC-MS/HR-MS) to further increase selectivity of steroid hormone quantification. Application of HR-MS demonstrates an enhanced selectivity compared to low mass resolution. Separation of isobaric interferences reduces background noise and avoids overestimation. Samples were prepared by automated liquid-liquid extraction with MTBE. The LC-MS/HR-MS method using a quadrupole-Orbitrap analyzer includes eight steroid hormones i.e. androstenedione, corticosterone, cortisol, cortisone, 11-deoxycortisol, 17-hydroxyprogesterone, progesterone, and testosterone. It has a run-time of 5.3min and was validated according to the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines. For most of the analytes coefficient of variation were 10% or lower and LOQs were determined significantly below 1ng/ml. Full product ion spectra including accurate masses substantiate compound identification by matching their masses and ratios with authentic standards. In summary, quantification of steroid hormones by LC-MS/HR-MS is applicable for clinical diagnostics and holds also promise for highly selective quantification of other small molecules. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Development of a Rapid LC-MS/MS Method for the Determination of Emerging Fusarium mycotoxins Enniatins and Beauvericin in Human Biological Fluids

    PubMed Central

    Serrano, Ana Belén; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2015-01-01

    A novel method for the simultaneous determination of enniatins A, A1, B and B1 and beauvericin, both in human urine and plasma samples, was developed and validated. The method consisted of a simple and easy pretreatment, specific for each matrix, followed by solid phase extraction (SPE) and detection by high performance liquid chromatography-tandem mass spectrometry with an electrospray ion source. The optimized SPE method was performed on graphitized carbon black cartridges after suitable dilution of the extracts, which allowed high mycotoxin absolute recoveries (76%–103%) and the removal of the major interferences from the matrix. The method was extensively evaluated for plasma and urine samples separately, providing satisfactory results in terms of linearity (R2 of 0.991–0.999), process efficiency (>81%), trueness (recoveries between 85% and 120%), intra-day precision (relative standard deviation, RSD < 18%), inter-day precision (RSD < 21%) and method quantification limits (ranging between 20 ng·L−1 and 40 ng·L−1 in plasma and between 5 ng·L−1 and 20 ng·L−1 in urine). Finally, the highly sensitive validated method was applied to some urine and plasma samples from different donors. PMID:26371043

  10. Simultaneous determination of guanidinoacetate, creatine and creatinine in urine and plasma by un-derivatized liquid chromatography-tandem mass spectrometry.

    PubMed

    Carling, R S; Hogg, S L; Wood, T C; Calvin, J

    2008-11-01

    Creatine plays an important role in the storage and transmission of phosphate-bound energy. The cerebral creatine deficiency syndromes (CCDS) comprise three inherited defects in creatine biosynthesis and transport. They are characterized by mental retardation, speech and language delay and epilepsy. All three disorders cause low-creatine signal on brain magnetic resonance spectroscopy (MRS); however, MRS may not be readily available and even when it is, biochemical tests are required to determine the underlying disorder. Analysis was performed by liquid chromatography-tandem mass spectrometry in positive ionization mode. Samples were analysed underivatized using a rapid 'dilute and shoot' approach. Chromatographic separation of the three compounds was achieved. Stable isotope internal standards were used for quantification. Creatine, creatinine and guanidinoacetate were measured with a 2.5 minute run time. For guanidinoacetate, the standard curve was linear to at least 5000 mumol/L and for creatine and creatinine it was linear to at least 25 mmol/L. The lower limit of quantitation was 0.4 mumol/L for creatine and guanidinoacetate and 0.8 mumol/L for creatinine. Recoveries ranged from 86% to 106% for the three analytes. Intra- and inter-assay variation for each analyte was <10% in both urine and plasma. A tandem mass spectrometric method has been developed and validated for the underivatized determination of guanidinoacetate, creatine and creatinine in human urine and plasma. Minimal sample preparation coupled with a rapid run time make the method applicable to the routine screening of patients with suspected CCDS.

  11. [Simultaneous determination of nine preservatives and sweeteners in yellow wine and wine by ultrafast liquid chromatography-tandem mass spectrometry].

    PubMed

    Chen, Xiaohong; Zhao, Yonggang; Yao, Shanshan; Li, Xiaoping; Jin, Micong

    2011-12-01

    A sensitive and selective analytical method based on ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) was developed for the simultaneous determination of nine preservatives and sweeteners in yellow wine and wine. After the sample was diluted by pure water, the UFLC separation was performed on a Shim-pack XR-ODS II column (100 mm x 2.0 mm, 2.2 microm) with a linear gradient elution program of acetonitrile-ammonium acetate (AmAc, 2.5 mmol/L)-trifluoroacetic acid (TFA, 0.01%, v/v) aqueous solution as the mobile phase. Electrospray ionization was applied and operated in the negative multiple reaction monitoring (MRM) mode. The results showed that the limits of detection (LODs, S/N > 3) for the nine analytes were in the range of 0.03 - 15.0 microg/L, and the limits of quantitation (LOQs, S/N > 10) were in the range of 0.1 - 50.0 microg/L. The calibration curves showed good linearity for the nine analytes in their detection ranges, and the correlation coefficients (r2) were larger than 0.998. The recoveries were between 96.2% and 100.5% with the relative standard deviations (RSDs) of 0.6% - 5.4% for yellow wine, and between 96.0% and 104.0% with the RSDs of 0.7% - 4.8% for wine. Additionally, the mass spectral characterizations of the nine food additives were studied and the fragmentation pathways were speculated. The method is sensitive, reproducible and adaptable to the simultaneous rapid determination of the nine food additives in different yellow wine and wine samples.

  12. Combined liquid chromatography-tandem mass spectrometry analysis of progesterone metabolites.

    PubMed

    Sinreih, Maša; Zukunft, Sven; Sosič, Izidor; Cesar, Jožko; Gobec, Stanislav; Adamski, Jerzy; Lanišnik Rižner, Tea

    2015-01-01

    Progesterone has a number of important functions throughout the human body. While the roles of progesterone are well known, the possible actions and implications of progesterone metabolites in different tissues remain to be determined. There is a growing body of evidence that these metabolites are not inactive, but can have significant biological effects, as anesthetics, anxiolytics and anticonvulsants. Furthermore, they can facilitate synthesis of myelin components in the peripheral nervous system, have effects on human pregnancy and onset of labour, and have a neuroprotective role. For a better understanding of the functions of progesterone metabolites, improved analytical methods are essential. We have developed a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection and quantification of progesterone and 16 progesterone metabolites that has femtomolar sensitivity and good reproducibility in a single chromatographic run. MS/MS analyses were performed in positive mode and under constant electrospray ionization conditions. To increase the sensitivity, all of the transitions were recorded using the Scheduled MRM algorithm. This LC-MS/MS method requires small sample volumes and minimal sample preparation, and there is no need for derivatization. Here, we show the application of this method for evaluation of progesterone metabolism in the HES endometrial cell line. In HES cells, the metabolism of progesterone proceeds mainly to (20S)-20-hydroxy-pregn-4-ene-3-one, (20S)-20-hydroxy-5α-pregnane-3-one and (20S)-5α-pregnane-3α,20-diol. The investigation of possible biological effects of these metabolites on the endometrium is currently undergoing.

  13. [Determination of six novel amide fungicides in vegetables and fruits by liquid chromatography-tandem mass spectrometry].

    PubMed

    Chen, Xiaolong; Li, Zhengxiang; Cao, Zhaoyun; Cao, Xiaolin; Chen, Mingxue

    2013-10-01

    A method was developed for the simultaneous determination of mepanipyrim, silthiofam, boscalid, fluopicolide, mandipropamid, cyflufenamid in vegetables and fruits by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analytes were extracted from the samples by acetonitrile and purified by Florisil SPE. The six novel amide fungicides were separated on a Poroshell 120 EC-C18 column with the mobile phases of water and acetonitrile, and finally detected by MS/MS with positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, quantified by external standard method. Under the optimal analytical conditions, the correlation coefficients (r) of the six novel amide fungicides were not lower than 0. 999 0 in the concentration range from 0.5 to 100 microg/L. The limits of detection (S/N > or = 3) of the method were 0.15 microg/kg for boscalid, silthiofam, mandipropamid, cyflufenamid, 0.10 microg/kg for mepanipyrim and 0.17 microg/kg for fluopicolide. The recovery tests were performed for the 7 types of vegetables and the 3 types of fruits at the spiked levels of 0.5, 5 and 50 microg/kg, and the recoveries of the six analytes ranged from 65% to 124% with the relative standard deviations (RSDs, n = 5) of 1%-18%. The matrix effects in vegetables and fruits of the six amide fungicides were significantly reduced by the purification of Florisil SPE compared with the modified QuEChERS. The method is easy, fast, sensitive and accurate, and can meet the requirements of the determination of the six amide fungicide residues in vegetables and fruits.

  14. [Determination of 11 anabolic hormones in fish tissue by multi-function impurity adsorption solid-phase extraction-ultrafast liquid chromatography-tandem mass spectrometry].

    PubMed

    Yao, Shanshan; Zhao, Yonggang; Li, Xiaoping; Chen, Xiaohong; Jin, Micong

    2012-06-01

    A method was developed for the determination of 11 anabolic hormones (boldenone, androstenedione, nandrolone, methandrostenolone, methyltestosterone, testosterone, testosterone acetate, trenbolone, testosterone propionate, stanozolol, fluoxymesterone) in fish by multi-function impurity adsorption solid-phase extraction-ultrafast liquid chromatography-tandem mass spectrometry. After the sample was extracted by methanol, the extract was cleaned-up quickly by C18 adsorbent, neutral alumina adsorbent and amino-functionalized nano-adsorbent. The separation was performed on a Shim-Pack XR-ODS II column (100 mm x 2.0 mm, 2.2 microm) using the mobile phases of 0.1% (v/v) formic acid in acetonitrile and 0.1% (v/v) formic acid solution in a gradient elution mode. The identification and quantification were achieved by using electrospray ionization in positive ion mode (ESI+) in multiple reaction monitoring (MRM) mode. The matrix-matched external standard calibration curves were used for quantitative determination. The results showed that the calibration curves were in good linearity for the eleven analytes with the correlation coefficients (r) more than 0.999. The limits of detection (LODs, S/N > 3) for the 11 anabolic hormones were from 0.03 microg/kg to 0.4 microg/kg and the limits of quantification (LOQs, S/N > 10) were from 0.1 microg/kg to 1.5 microg/kg. The average recoveries ranged from 80.9% to 98.1% with the relative standard deviations between 5.2% and 11.5%. The method is simple, rapid, sensitive, accurate and suitable for the quantitative determination and confirmation of the 11 anabolic hormones in fish.

  15. Resolution of R-(-) and S-(+)- enantiomers of clenbuterol in pharmaceutical preparations and black-market products using liquid chromatography-tandem mass spectrometry.

    PubMed

    Velasco-Bejarano, Benjamín; Bautista, Jahir; Noguez, Ma Olivia; Camacho, Evangelina; Rodríguez, Martha E; Rodríguez, Leonardo

    2017-11-01

    Several banned substances are illegally used by athletes in racemic mixtures for performance enhancement. These include clenbuterol, methyl hexaneamine, methamphetamines, and amphetamines. Clenbuterol is present in a large number of doping samples from Olympic and non-Olympic athletes that have adverse analytical findings (AAFs). In some cases, the presence of these substances could be the result of consumption of meat contaminated with clenbuterol. In other cases, the origin is not clear. In this study, 27 products with racemic clenbuterol were evaluated using a new analytical methodology for the resolution of R-(-) and S-(+)-enantiomers of clenbuterol by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using a chiral column in 15 min with good separation. The method developed can also be used for the analysis of other biological matrices such as urine, serum, and meat. The resolution between two peaks' (R s ) value obtained using chromatographic data was 1.03. Both clenbuterol enantiomers were present in all products analyzed and the ratio was nearly 1. The origin of the product was not important for determining the presence of one or both enantiomers. All products displayed a 50:50 ratio of clenbuterol enantiomers. To the best of our knowledge, clenbuterol ratio determination of a large number of pharmaceutical preparations and black-market products has not been reported previously. The information shown could be used by national anti-doping organizations and the athletes with AAFs attributed to clenbuterol. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Development of multiclass methods for drug residues in eggs: hydrophilic solid-phase extraction cleanup and liquid chromatography/tandem mass spectrometry analysis of tetracycline, fluoroquinolone, sulfonamide, and beta-lactam residues.

    PubMed

    Heller, David N; Nochetto, Cristina B; Rummel, Nathan G; Thomas, Michael H

    2006-07-26

    A method was developed for detection of a variety of polar drug residues in eggs via liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). A total of twenty-nine target analytes from four drug classes-sulfonamides, tetracyclines, fluoroquinolones, and beta-lactams-were extracted from eggs using a hydrophilic-lipophilic balance polymer solid-phase extraction (SPE) cartridge. The extraction technique was developed for use at a target concentration of 100 ng/mL (ppb), and it was applied to eggs containing incurred residues from dosed laying hens. The ESI source was tuned using a single, generic set of tuning parameters, and analytes were separated with a phenyl-bonded silica cartridge column using an LC gradient. In a related study, residues of beta-lactam drugs were not found by LC/MS/MS in eggs from hens dosed orally with beta-lactam drugs. LC/MS/MS performance was evaluated on two generations of ion trap mass spectrometers, and key operational parameters were identified for each instrument. The ion trap acquisition methods could be set up for screening (a single product ion) or confirmation (multiple product ions). The lower limit of detection for screening purposes was 10-50 ppb (sulfonamides), 10-20 ppb (fluoroquinolones), and 10-50 ppb (tetracyclines), depending on the drug, instrument, and acquisition method. Development of this method demonstrates the feasibility of generic SPE, LC, and MS conditions for multiclass LC/MS residue screening.

  17. Fluconazole Pharmacokinetics in Galleria mellonella Larvae and Performance Evaluation of a Bioassay Compared to Liquid Chromatography-Tandem Mass Spectrometry for Hemolymph Specimens

    PubMed Central

    Astvad, Karen Marie Thyssen; Meletiadis, Joseph; Whalley, Sarah

    2017-01-01

    ABSTRACT The invertebrate model organism Galleria mellonella can be used to assess the efficacy of treatment of fungal infection. The fluconazole dose best mimicking human exposure during licensed dosing is unknown. We validated a bioassay for fluconazole detection in hemolymph and determined the fluconazole pharmacokinetics and pharmacodynamics in larval hemolymph in order to estimate a humanized dose for future experiments. A bioassay using 4-mm agar wells, 20 μl hemolymph, and the hypersusceptible Candida albicans DSY2621 was established and compared to a validated liquid chromatography-tandem mass spectrometry (LC–MS-MS) method. G. mellonella larvae were injected with fluconazole (5, 10, and 20 mg/kg of larval weight), and hemolymph was harvested for 24 h for pharmacokinetics calculations. The exposure was compared to the human exposure during standard licensed dosing. The bioassay had a linear standard curve between 1 and 20 mg/liter. Accuracy and coefficients of variation (percent) values were below 10%. The Spearman coefficient between assays was 0.94. Fluconazole larval pharmacokinetics followed one-compartment linear kinetics, with the 24-h area under the hemolymph concentration-time curve (AUC24 h) being 93, 173, and 406 mg · h/liter for the three doses compared to 400 mg · h/liter in humans under licensed treatment. In conclusion, a bioassay was validated for fluconazole determination in hemolymph. The pharmacokinetics was linear. An exposure comparable to the human exposure during standard licensed dosing was obtained with 20 mg/kg. PMID:28760893

  18. Transcriptome and secretome analyses of Phanerochaete chrysosporium reveal complex patterns of gene expression

    Treesearch

    Amber J. Vanden Wymelenberg; Jill A. Gaskell; Michael D. Mozuch; Philip J. Kersten; Grzegorz Sabat; Diego Martinez; Daniel Cullen

    2009-01-01

    The wood decay basidiomycete Phanerochaete chrysosporium was grown under standard ligninolytic or cellulolytic conditions and subjected to whole-genome expression microarray analysis and liquid chromatography-tandem mass spectrometry of extracellular proteins. A total of 545 genes were flagged on the basis of significant changes in transcript accumulation and/or...

  19. Evaluation of a multiclass, multiresidue liquid chromatography-tandem mass spectrometry method for analysis of 120 veterinary drugs in bovine kidney

    USDA-ARS?s Scientific Manuscript database

    Traditionally, regulatory monitoring of veterinary drug residues in food animal tissues involves the use of several single-class methods to cover a wide analytical scope. Multiclass, multiresidue methods of analysis tend to provide greater overall laboratory efficiency than the use of multiple meth...

  20. Refined methodology for the determination of neonicotinoid pesticides and their metabolites in honey bees and bee products by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    PubMed

    Kamel, Alaa

    2010-05-26

    An analytical method was refined for the extraction and determination of neonicotinoid pesticide residues and their metabolites in honey bees and bee products. Samples were extracted with 2% triethylamine (TEA) in acetonitrile (ACN) followed by salting out, solid phase extraction (SPE) cleanup, and detection using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated in triplicate at three fortification concentrations in each matrix. Good recoveries were observed for most analytes and ranged between 70 and 120% with relative standard deviations between replicates of <20% in most cases. The method limits of detection were 0.2 ng/g for the parent neonicotinoid pesticides and ranged between 0.2 and 15 ng/g for the neonicotinoid metabolites. This refined method provides lower detection limits and improved recovery of neonicotinoids and their metabolites, which will help researchers evaluate subchronic effects of these pesticides, address data gaps related to colony collapse disorder (CCD), and determine the role of pesticides in pollinator decline.

  1. Quantification of Major Royal Jelly Protein 1 in Fresh Royal Jelly by Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Lin, Na; Chen, Si; Zhang, Hong; Li, Junmin; Fu, Linglin

    2018-02-07

    Major royal jelly protein 1 (MRJP1) is the most abundant protein in royal jelly (RJ), and the level of MRJP1 has been suggested as a promising parameter for standardization and evaluation of RJ authenticity in quality. Here, a quantitative method was developed for the quantification of MRJP1 in RJ based on a signature peptide and a stable isotope-labeled internal standard peptide FFDYDFGSDER*(R*, 13 C 6 , 15 N 4 ) by ultraperformance liquid chromatography-tandem mass spectrometry. Recoveries of the established method ranged from 85.33 to 95.80%, and both the intra- and interday precision were RSD < 4.97%. Quantification results showed that content of MRJP1 in fresh RJ was 41.96-55.01 mg/g. Abnormal levels of MRJP1 were found in three commercial RJs and implied that these samples were of low quality and might be adulterated. Results of the present work suggested that the developed method could be successfully applied to quantify MRJP1 in RJ and also could evaluate the quality of RJ.

  2. Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Shin, Yongho; Lee, Jonghwa; Lee, Jiho; Lee, Junghak; Kim, Eunhye; Liu, Kwang-Hyeon; Lee, Hye Suk; Kim, Jeong-Han

    2018-04-04

    A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was established. The limit of quantitation was 10 ng/mL for 94.5% of the total pesticides, and the correlation coefficients of calibration were ≥0.990 for 93.9% of the pesticides. For the sample preparation, scaled-down QuEChERS were used. Serum (100 μL) was extracted with acetonitrile (400 μL), partitioned with magnesium sulfate (40 mg) and sodium chloride (10 mg), and the upper layer was used for analysis without further cleanup steps. For the accuracy and precision tests, most of the pesticides showed excellent results in intra- and interday conditions. In the recovery tests at 10, 50, and 250 ng/mL, 85.8-91.8% of all target compounds satisfied the recovery range of 70-120% (relative standard deviation ≤20%).

  3. Survey of Deoxynivalenol and Aflatoxin B1 in Instant Noodles and Bread Consumed in Thailand by Using Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Pralatnet, Sasithorn; Poapolathep, Saranya; Giorgi, Mario; Imsilp, Kanjana; Kumagai, Susumu; Poapolathep, Amnart

    2016-07-01

    One hundred wheat product samples (50 instant noodle samples and 50 bread samples) were collected from supermarkets in Bangkok, Thailand. Deoxynivalenol (DON) and aflatoxin B1 (AFB1) contamination in these products was analyzed using a validated liquid chromatography-tandem mass spectrometry method. The limit of quantification values of DON and AFB1 in the instant noodles and bread were 2 and 1 ng g(-1), respectively. The survey found that DON was quantifiable in 40% of collected samples, in 2% of noodles (0.089 μg g(-1)), and in 78% of breads (0.004 to 0.331 μg g(-1)). AFB1 was below the limit of quantification of the method in all of the tested samples. The results suggest that the risk of DON exposure via noodles and breads is very low in urban areas of Thailand. No risk can be attributable to AFB1 exposure in the same food matrices, but further studies with a larger sample size are needed to confirm these data.

  4. Detection and quantitation of trace phenolphthalein (in pharmaceutical preparations and in forensic exhibits) by liquid chromatography-tandem mass spectrometry, a sensitive and accurate method.

    PubMed

    Sharma, Kakali; Sharma, Shiba P; Lahiri, Sujit C

    2013-01-01

    Phenolphthalein, an acid-base indicator and laxative, is important as a constituent of widely used weight-reducing multicomponent food formulations. Phenolphthalein is an useful reagent in forensic science for the identification of blood stains of suspected victims and for apprehending erring officials accepting bribes in graft or trap cases. The pink-colored alkaline hand washes originating from the phenolphthalein-smeared notes can easily be determined spectrophotometrically. But in many cases, colored solution turns colorless with time, which renders the genuineness of bribe cases doubtful to the judiciary. No method is known till now for the detection and identification of phenolphthalein in colorless forensic exhibits with positive proof. Liquid chromatography-tandem mass spectrometry had been found to be most sensitive, accurate method capable of detection and quantitation of trace phenolphthalein in commercial formulations and colorless forensic exhibits with positive proof. The detection limit of phenolphthalein was found to be 1.66 pg/L or ng/mL, and the calibration curve shows good linearity (r(2) = 0.9974). © 2012 American Academy of Forensic Sciences.

  5. Optimization of Analytical Conditions for a Rapid Determination of Aniline in Environmental Water by Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi

    2017-01-01

    A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d 5 ). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.

  6. Synthesis and characterization of a molecularly imprinted polymer for the determination of trace tributyltin in seawater and seafood by liquid chromatography-tandem mass spectroscopy.

    PubMed

    Zhu, Shanshan; Hu, Futao; Yang, Ting; Gan, Ning; Pan, Daodong; Cao, Yuting; Wu, Dazhen

    2013-03-15

    Analysis of tributyltin chloride (TBT) in environmental samples, such as seawater, is important in order to evaluate the TBT contamination and accumulation in the trophic chain. The environmental impact of organotin compounds has been a particular focus of analytical studies. The present study reports the use of molecular imprinting technology coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine trace amounts of TBT in seawater and seafood (mussel tissue samples). The imprinted polymer was synthesized by a non-covalent free-radical approach using acrylamide (AM) as a monomer and TBT as a template molecule in acetonitrile solvent (polymerization media). The imprinted polymer synthesized by this approach exhibited good adsorptive capacity and allowed specific retention of TBT. Recoveries of TBT in seawater samples spiked with different TBT concentrations ranged from 67.2% to 81.1% with peak area precision (RSD)<3.7%, and recoveries of TBT in mussel tissue samples ranged from 75.0% to 94.2% with RSD<4.8%. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Validation of a confirmatory method for the determination of residues of four nitrofurans in egg by liquid chromatography-tandem mass spectrometry with the software InterVal.

    PubMed

    Bock, C; Stachel, C; Gowik, P

    2007-03-14

    A method for the detection and determination of nitrofuran derivatives in egg by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was validated with the software InterVal and can be applied for the confirmation of nitrofuran metabolites in fresh or lyophilised eggs. The validation study comprises variations in operator, storage condition, breeding, equipment and duration of sample preparation. A comprehensive overview of the robustness of the method is obtained by analysing eight samples at six concentration levels. First results of short- and medium-term investigations for stability of analytes in solution show that standard solutions of nitrofuran metabolites are stable for at least 1 year when stored at +4 degrees C in the dark. The decision limit CCalpha expressed for the underivatised metabolite is 0.05 microg kg(-1) for 3-amino-5-methyl-morpholino-2-oxazolidinone, 0.03 microg kg(-1) for 3-amino-2-oxazolidinone, 0.20 microg kg(-1) for semicarbazide and 0.22 microg kg(-1) for 1-amino-hydantoin.

  8. Absolute quantification of Pru av 2 in sweet cherry fruit by liquid chromatography/tandem mass spectrometry with the use of a stable isotope-labelled peptide.

    PubMed

    Ippoushi, Katsunari; Sasanuma, Motoe; Oike, Hideaki; Kobori, Masuko; Maeda-Yamamoto, Mari

    2016-08-01

    Pru av 2, a pathogenesis-related (PR) protein present in the sweet cherry (Prunus avium L.) fruit, is the principal allergen of cherry and one of the chief causes of pollen food syndrome (oral allergy syndrome). In this study, a quantitative assay for this protein was developed with the use of the protein absolute quantification (AQUA) method, which consists of liquid chromatography/tandem mass spectrometry (LC/MS/MS) employing TGC[CAM]STDASGK[(13)C6,(15)N2], a stable isotope-labelled internal standard (SIIS) peptide. This assay gave a linear relationship (r(2)>0.99) in a concentration range (2.3-600fmol/μL), and the overall coefficient of variation (CV) for multiple tests was 14.6%. Thus, the contents of this allergenic protein in sweet cherry products could be determined using this assay. This assay should be valuable for allergological investigations of Pru av 2 in sweet cherry and detection of protein contamination in foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Analysis of processing contaminants in edible oils. Part 2. Liquid chromatography-tandem mass spectrometry method for the direct detection of 3-monochloropropanediol and 2-monochloropropanediol diesters.

    PubMed

    MacMahon, Shaun; Begley, Timothy H; Diachenko, Gregory W

    2013-05-22

    A method was developed and validated for the detection of fatty acid diesters of 2-monochloropropanediol (2-MCPD) and 3-monochloropropanediol (3-MCPD) in edible oils. These analytes are potentially carcinogenic chemical contaminants formed during edible oil processing. After separation from oil matrices using a two-step solid-phase extraction (SPE) procedure, the target compounds are quantitated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). The first chromatographic conditions have been developed that separate intact diesters of 2-MCPD and 3-MCPD, allowing for their individual quantitation. The method has been validated for 28 3-MCPD diesters of lauric, myristic, palmitic, linolenic, linoleic, oleic, and stearic acids in coconut, olive, and palm oils, as well as 3 2-MCPD diesters, using an external calibration curve. The range of average recoveries and relative standard deviations (RSDs) across the three oil matrices at three spiking concentrations are 88-118% (2-16% RSD) with maximum limits of quantitation of 30 ng/g (ppb).

  10. Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine.

    PubMed

    Fraselle, S; De Cremer, K; Coucke, W; Glorieux, G; Vanmassenhove, J; Schepers, E; Neirynck, N; Van Overmeire, I; Van Loco, J; Van Biesen, W; Vanholder, R

    2015-04-15

    Despite decades of creatinine measurement in biological fluids using a large variety of analytical methods, an accurate determination of this compound remains challenging. Especially with the novel trend to assess biomarkers on large sample sets preserved in biobanks, a simple and fast method that could cope with both a high sample throughput and a low volume of sample is still of interest. In answer to these challenges, a fast and accurate ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to measure creatinine in small volumes of human urine. In this method, urine samples are simply diluted with a basic mobile phase and injected directly under positive electrospray ionization (ESI) conditions, without further purification steps. The combination of an important diluting factor (10(4) times) due to the use of a very sensitive triple quadrupole mass spectrometer (XEVO TQ) and the addition of creatinine-d3 as internal standard completely eliminates matrix effects coming from the urine. The method was validated in-house in 2012 according to the EMA guideline on bioanalytical method validation using Certified Reference samples from the German External Quality Assessment Scheme (G-Equas) proficiency test. All obtained results for accuracy and recovery are within the authorized tolerance ranges defined by G-Equas. The method is linear between 0 and 5 g/L, with LOD and LOQ of 5 × 10(-3) g/L and 10(-2) g/L, respectively. The repeatability (CV(r) = 1.03-2.07%) and intra-laboratory reproducibility (CV(RW) = 1.97-2.40%) satisfy the EMA 2012 guideline. The validated method was firstly applied to perform the German G-Equas proficiency test rounds 51 and 53, in 2013 and 2014, respectively. The obtained results were again all within the accepted tolerance ranges and very close to the reference values defined by the organizers of the proficiency test scheme, demonstrating an excellent accuracy of the developed method. The method was finally applied to measure the creatinine concentration in 210 urine samples, coming from 190 patients with a chronic kidney disease (CKD) and 20 healthy subjects. The obtained creatinine concentrations (ranging from 0.12 g/L up to 3.84 g/L) were compared, by means of a Passing Bablok regression, with the creatinine contents obtained for the same samples measured using a traditional compensated Jaffé method. The UHPLC-MS/MS method described in this paper can be used to normalize the concentration of biomarkers in urine for the extent of dilution. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. A sensitive and selective liquid chromatography/tandem mass spectrometry method for quantitative analysis of efavirenz in human plasma.

    PubMed

    Srivastava, Praveen; Moorthy, Ganesh S; Gross, Robert; Barrett, Jeffrey S

    2013-01-01

    A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and ¹³C₆-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (¹³C₆-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0-2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100-111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03-9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2-108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients.

  12. Metabolite identification and pharmacokinetic profiling of PP242, an ATP-competitive inhibitor of mTOR using ultra high-performance liquid chromatography and mass spectrometry.

    PubMed

    Rashid, Md Mamunur; Lee, Hyunbeom; Jung, Byung Hwa

    2018-01-01

    PP242 is a second generation novel selective ATP-competitive inhibitor of mTOR that displayed promising anti-cancer activity over several cancer types by inhibiting both the complexes of mTOR (mTORC1 and mTORC2). The purpose of this study is to identify the possible metabolites and to evaluate the pharmacokinetic profile of PP242 after a single oral administration to Sprague-Dawley (SD) rats. Two metabolites, including one phase I and one phase II, were identified by in vitro and in vivo studies using rat liver microsomes (RLMs) as well as rat plasma, urine and feces, respectively, through ultra high-performance liquid chromatography-linear ion trap quadrupole-orbitrap-mass spectrometry (UHPLC-LTQ-Orbitrap-MS). The major biotransformation pathways of PP242 were hydroxylation and glucuronide conjugation. Additionally, a simple and rapid quantification method was developed and validated. The method recovery was within 79.7-84.6%, whereas the matrix effect was 78.1-96.0% in all three quality control (QC) concentrations (low, medium and high) including the LLOQ. Other parameters showed acceptable results according to the US food and drug administration (FDA) guidelines for bioanalytical method validation. Afterwards, pharmacokinetic parameters were evaluated in rat plasma by successfully applying the validated method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). After a single oral administration at a dose of 5mg/kg, the maximum plasma concentration (C max ) of PP242 was 0.17±0.08μg/mL, while the elimination was moderately fast (T 1/2 : 172.18±45.54min). All of the obtained information on the metabolite identification and pharmacokinetic parameter elucidation could facilitate the further development of PP242. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Simultaneous quantification of lenalidomide, ibrutinib and its active metabolite PCI-45227 in rat plasma by LC-MS/MS: application to a pharmacokinetic study.

    PubMed

    Veeraraghavan, Sridhar; Viswanadha, Srikant; Thappali, Satheeshmanikandan; Govindarajulu, Babu; Vakkalanka, Swaroopkumar; Rangasamy, Manivannan

    2015-03-25

    Efficacy assessments using a combination of ibrutinib and lenalidomide necessitate the development of an analytical method for determination of both drugs in plasma with precision. A high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of lenalidomide, ibrutinib, and its active metabolite PCI45227 in rat plasma. Extraction of lenalidomide, ibrutinib, PCI45227 and tolbutamide (internal standard; IS) from 50 μl rat plasma was carried out by liquid-liquid extraction with ethyl acetate:dichloromethane (90:10) ratio. Chromatographic separation of analytes was performed on YMC pack ODS AM (150 mm × 4.6 mm, 5 μm) column under gradient conditions with acetonitrile:0.1% formic acid buffer as the mobile phases at a flow rate of 1 ml/min. Precursor ion and product ion transition for analytes and IS were monitored on a triple quadrupole mass spectrometer, operated in the selective reaction monitoring with positive ionization mode. Method was validated over a concentration range of 0.72-183.20 ng/ml for ibrutinib, 0.76-194.33 ng/ml for PCI-45227 and 1.87-479.16 ng/ml for lenalidomide. Mean extraction recovery for ibrutinib, PCI-45227, lenalidomide and IS of 75.2%, 84.5%, 97.3% and 92.3% were consistent across low, medium, and high QC levels. Precision and accuracy at low, medium and high quality control levels were less than 15% across analytes. Bench top, wet, freeze-thaw and long term stability was evaluated for all the analytes. The analytical method was applied to support a pharmacokinetic study of simultaneous estimation of lenalidomide, ibrutinib, and its active metabolite PCI-45227 in Wistar rat. Assay reproducibility was demonstrated by re-analysis of 18 incurred samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Benthic cyanobacteria: A source of cylindrospermopsin and microcystin in Australian drinking water reservoirs.

    PubMed

    Gaget, Virginie; Humpage, Andrew R; Huang, Qiong; Monis, Paul; Brookes, Justin D

    2017-11-01

    Cyanobacteria represent a health hazard worldwide due to their production of a range of highly potent toxins in diverse aquatic environments. While planktonic species have been the subject of many investigations in terms of risk assessment, little is known about benthic forms and their impact on water quality or human and animal health. This study aimed to purify isolates from environmental benthic biofilms sampled from three different drinking water reservoirs and to assess their toxin production by using the following methods: Enzyme-Linked Immunosorbent Assay (ELISA), High-Performance Liquid Chromatography (HPLC), Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and quantitative PCR (qPCR). Microscopic observation of the isolates allowed the identification of various filamentous cyanobacterial genera: Anabaena (benthic form), Calothrix and Nostoc from the Nostocales and Geitlerinema, Leptolyngbya, Limnothrix, Lyngbya, Oxynema, Phormidium and Pseudanabaena representing non-heterocystous filamentous cyanobacteria. The Phormidium ambiguum strain AWQC-PHO021 was found to produce 739 ng/mg of dry weight (d/w) of cylindrospermopsin and 107 ng/mg (d/w) of deoxy-cylindrospermopsin. The Nostoc linckia strain AWQC-NOS001 produced 400 ng/mg (d/w) of a microcystin analogue. This is the first report of hepatotoxin production by benthic cyanobacteria in temperate Australian drinking water reservoirs. These findings indicate that water quality monitoring programs need to consider benthic cyanobacteria as a potential source of toxins. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Post-column infusion study of the 'dosing vehicle effect' in the liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples.

    PubMed

    Shou, Wilson Z; Naidong, Weng

    2003-01-01

    It has become increasingly popular in drug development to conduct discovery pharmacokinetic (PK) studies in order to evaluate important PK parameters of new chemical entities (NCEs) early in the discovery process. In these studies, dosing vehicles are typically employed in high concentrations to dissolve the test compounds in dose formulations. This can pose significant problems for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of incurred samples due to potential signal suppression of the analytes caused by the vehicles. In this paper, model test compounds in rat plasma were analyzed using a generic fast gradient LC/MS/MS method. Commonly used dosing vehicles, including poly(ethylene glycol) 400 (PEG 400), polysorbate 80 (Tween 80), hydroxypropyl beta-cyclodextrin, and N,N-dimethylacetamide, were fortified into rat plasma at 5 mg/mL before extraction. Their effects on the sample analysis results were evaluated by the method of post-column infusion. Results thus obtained indicated that polymeric vehicles such as PEG 400 and Tween 80 caused significant suppression (> 50%, compared with results obtained from plasma samples free from vehicles) to certain analytes, when minimum sample cleanup was used and the analytes happened to co-elute with the vehicles. Effective means to minimize this 'dosing vehicle effect' included better chromatographic separations, better sample cleanup, and alternative ionization methods. Finally, a real-world example is given to illustrate the suppression problem posed by high levels of PEG 400 in sample analysis, and to discuss steps taken in overcoming the problem. A simple but effective means of identifying a 'dosing vehicle effect' is also proposed. Copyright 2003 John Wiley & Sons, Ltd.

  16. Direct Determination of Six Cytokinin Nucleotide Monophosphates in Coconut Flesh by Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Cao, Zhao-Yun; Ma, You-Ning; Sun, Li-Hua; Mou, Ren-Xiang; Zhu, Zhi-Wei; Chen, Ming-Xue

    2017-11-15

    Coconut contains many uncharacterized cytokinins that have important physiological effects in plants and humans. In this work, a method based on liquid chromatography-tandem mass spectrometry was developed for identification and quantification of six cytokinin nucleotide monophosphates in coconut flesh. Excellent separation was achieved using a low-coverage C18 bonded-phase column with an acidic mobile phase, which greatly improved the retention of target compounds. To enable high-throughput analysis, a single-step solid-phase extraction using mixed-mode anion-exchange cartridges was employed for sample preparation. This proved to be an effective method to minimize matrix effects and ensure high selectivity. The limits of detection varied from 0.06 to 0.3 ng/mL, and the limits of quantification ranged from 0.2 to 1.0 ng/mL. The linearity was statistically verified over 2 orders of magnitude, giving a coefficient of determination (R 2 ) greater than 0.9981. The mean recoveries were from 81 to 108%; the intraday precision (n = 6) was less than 11%; and the interday precision (n = 11) was within 14%. The developed method was applied to the determination of cytokinin nucleotide monophosphates in coconut flesh samples, and four of them were successfully identified and quantified. The results showed that trans-zeatin riboside-5'-monophosphate was the dominant cytokinin, with a concentration of 2.7-34.2 ng/g, followed by N 6 -isopentenyladenosine-5'-monophosphate (≤12.9 ng/g), while the concentrations of cis-zeatin riboside-5'-monophosphate and dihydrozeatin riboside-5'-monophosphate were less than 2.2 and 4.9 ng/g, respectively.

  17. Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater.

    PubMed

    Bijlsma, Lubertus; Sancho, Juan V; Pitarch, Elena; Ibáñez, Maria; Hernández, Félix

    2009-04-10

    An ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method has been developed for the simultaneous quantification and confirmation of 11 basic/acidic illicit drugs and relevant metabolites in surface and urban wastewater at ng/L levels. The sample pre-treatment consisted of a solid-phase extraction using Oasis MCX cartridges. Analyte deuterated compounds were used as surrogate internal standards (except for norbenzoylecgonine and norcocaine) to compensate for possible errors resulting from matrix effects and those associated to the sample preparation procedure. After SPE enrichment, the selected drugs were separated within 6min under UHPLC optimized conditions. To efficiently combine UHPLC with MS/MS, a fast-acquisition triple quadrupole mass analyzer (TQD from Waters) in positive-ion mode (ESI+) was used. The excellent selectivity and sensitivity of the TQD analyzer in selected reaction monitoring mode allowed quantification and reliable identification at the LOQ levels. Satisfactory recoveries (70-120%) and precision (RSD<20%) were obtained for most compounds in different types of water samples, spiked at two concentration levels [limit of quantification (LOQ) and 10LOQ]. Thus, surface water was spiked at 30 ng/L and 300 ng/L (amphetamine and amphetamine-like stimulants), 10 ng/L and 100 ng/L (cocaine and its metabolites), 300 ng/L and 3000 ng/L (tetrahydrocannabinol-COOH). Recovery experiments in effluent and influent wastewater were performed at spiking levels of three and fifteen times higher than the levels spiked in surface water, respectively. The validated method was applied to urban wastewater samples (influent and effluent). The acquisition of three selected reaction monitoring transitions per analyte allowed positive findings to be confirmed by accomplishment of ion ratios between the quantification transition and two additional specific confirmation transitions. In general, drug consumption increased in the weekends and during an important musical event. The highest concentration levels were 27.5 microg/L and 10.5 microg/L, which corresponded to 3,4-methylenedioxymethamphetamine (MDMA, or ecstasy) and to benzoylecgonine (a cocaine metabolite), respectively. The wastewater treatment plants showed good removal efficiency (>99%) for low levels of illicit drugs in water, but some difficulties were observed when high drug levels were present in wastewaters.

  18. Method development and validation for total haloxyfop analysis in infant formulas and related ingredient matrices using liquid chromatography-tandem mass spectrometry.

    PubMed

    Koesukwiwat, Urairat; Vaclavik, Lukas; Mastovska, Katerina

    2018-05-08

    According to the European Commission directive 2006/141/EC, haloxyfop residue levels should not exceed 0.003 mg/kg in ready-to-feed infant formula, and the residue definition includes sum of haloxyfop, its esters, salts, and conjugates expressed as haloxyfop. A simple method for total haloxyfop analysis in infant formula and related ingredient matrices was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The sample preparation consisted of an alkaline hydrolysis with methanolic sodium hydroxide to release haloxyfop (parent acid) from its bound forms prior to the extraction with acetonitrile. A mixture of magnesium sulfate (MgSO 4 ) and sodium chloride (NaCl) (4:1, w/w) was added to the extract to induce phase separation and force the analyte into the upper acetonitrile-methanol layer and then a 1-mL aliquot was subsequently cleaned up by dispersive solid phase extraction with 150 mg of MgSO 4 and 50 mg of octadecyl (C 18 ) sorbent. The analytical procedure was developed and carefully optimized to enable low-level, total haloxyfop analysis in a variety of challenging matrices, including infant formulas and their important high-carbohydrate, high-protein, high-fat, and emulsifier ingredients. The final method was validated in two different laboratories by fortifying samples with haloxyfop and haloxyfop-methyl, which was used as a model compound simulating bound forms of the analyte. Mean recoveries of haloxyfop across all fortification levels and evaluated matrices ranged between 92.2 and 114% with repeatability, within-lab reproducibility, and reproducibility RSDs ≤ 14%. Based on the validation results, this method was capable to convert the haloxyfop ester into the parent acid in a wide range of sample types and to reliably identify and quantify total haloxyfop at the target 0.003 mg/kg level in infant formulas (both powdered and ready-to-feed liquid forms). Graphical abstract LC-MS/MS-based workflow for the determination of the total haloxyfop in infant formula and related ingredients.

  19. Liquid chromatography-tandem mass spectrometry method for simultaneous quantification of urapidil and aripiprazole in human plasma and its application to human pharmacokinetic study.

    PubMed

    Ambavaram, Vijaya Bhaskar Reddy; Nandigam, Venugopal; Vemula, Madhavi; Kalluru, Gangadhara Reddy; Gajulapalle, Madhavi

    2013-07-01

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of urapidil and aripiprazole in human plasma. A simple liquid-liquid extraction with ethyl acetate was used for the sample preparation. Chromatographic separation was achieved on a Phenomenex C18 (4.6 × 50 mm, 5 µm) column with 0.1% formic acid-acetonitrile (10:90, v/v) as the mobile phase with flow rate of 0.6 mL/min. The quantitation of the target compounds was determined in a positive ion multiple reaction monitoring mode. Calibration plots were linear over the range of 2.0-2503.95 ng/mL for urapidil and 1.0-500.19 ng/mL for aripiprazole. The lower limit of quantitation for urapidil and aripiprazole was 2.0 and 1.0 ng/mL, respectively. Mean recovery was in the range of 69.94-75.62% for both analytes and internal standards. Intra-day and inter-day precisions of the assay at three concentrations were 2.56-5.89% with accuracy of 92.31-97.83% for urapidil, and 3.14-6.84% with accuracy of 91.38-94.42% for aripiprazole. The method was successfully applied to human pharmacokinetic study of urapidil and aripiprazole in healthy human male volunteers. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Immunochemical Analysis of Paxilline and Ergot Alkaloid Mycotoxins in Grass Seeds and Plants.

    PubMed

    Bauer, Julia I; Gross, Madeleine; Cramer, Benedikt; Humpf, Hans-Ulrich; Hamscher, Gerd; Usleber, Ewald

    2018-01-10

    Limited availability of toxin standards for lolitrem B and ergovaline impedes routine control of grasses for endophyte toxins. This study aimed at assessing the applicability of an enzyme immunoassay (EIA) for the indole-diterpene mycotoxin paxilline, in combination with a generic EIA for ergot alkaloids, as alternative parameters for screening purposes. Analysis of grass seeds and model pastures of four different grass species showed that both EIAs yielded highly positive results for paxilline and ergot alkaloids in perennial ryegrass seeds. Furthermore, evidence for natural occurrence of paxilline in grass in Germany was obtained. High performance liquid chromatography-tandem mass spectrometry analysis qualitatively confirmed the paxilline EIA results but showed that paxilline analogues 1'-O-acetylpaxilline and 13-desoxypaxilline were the predominant compounds in seeds and grass. In the absence of easily accessible reference standards for specific analysis of some major endophyte toxins, analysis of paxilline and ergot alkaloids by EIA may be suitable substitute parameters. The major advantage of this approach is its ease of use and speed, providing an analytical tool which could enhance routine screening for endophyte toxins in pasture.

Top