Asbach, Patrick; Hein, Patrick A; Stemmer, Alto; Wagner, Moritz; Huppertz, Alexander; Hamm, Bernd; Taupitz, Matthias; Klessen, Christian
2008-01-01
To evaluate soft tissue contrast and image quality of a respiratory-triggered echo-planar imaging based diffusion-weighted sequence (EPI-DWI) with different b values for magnetic resonance imaging (MRI) of the liver. Forty patients were examined. Quantitative and qualitative evaluation of contrast was performed. Severity of artifacts and overall image quality in comparison with a T2w turbo spin-echo (T2-TSE) sequence were scored. The liver-spleen contrast was significantly higher (P < 0.05) for the EPI-DWI compared with the T2-TSE sequence (0.47 +/- 0.11 (b50); 0.48 +/- 0.13 (b300); 0.47 +/- 0.13 (b600) vs 0.38 +/- 0.11). Liver-lesion contrast strongly depends on the b value of the DWI sequence and decreased with higher b values (b50, 0.47 +/- 0.19; b300, 0.40 +/- 0.20; b600, 0.28 +/- 0.23). Severity of artifacts and overall image quality were comparable to the T2-TSE sequence when using a low b value (P > 0.05), artifacts increased and image quality decreased with higher b values (P < 0.05). Respiratory-triggered EPI-DWI of the liver is feasible because good image quality and favorable soft tissue contrast can be achieved.
Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar
2015-01-01
Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055
ERIC Educational Resources Information Center
Novis-Deutsch, Nurit; Lifshitz, Chen
2016-01-01
The integration of highly religious minority students into institutions of higher education poses significant pedagogical and value challenges for students and teachers alike. We offer a framework for analyzing such challenges, distinguishing between practical concerns, identity issues and value conflicts. By contrasting a deficit perspective to…
Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L.
2013-01-01
The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus. PMID:23369980
Kawahara, Daisuke; Ozawa, Shuichi; Yokomachi, Kazushi; Tanaka, Sodai; Higaki, Toru; Fujioka, Chikako; Suzuki, Tatsuhiko; Tsuneda, Masato; Nakashima, Takeo; Ohno, Yoshimi; Nagata, Yasushi
2018-02-01
To evaluate the accuracy of raw-data-based effective atomic number (Z eff ) values and monochromatic CT numbers for contrast material of varying iodine concentrations, obtained using dual-energy CT. We used a tissue characterization phantom and varying concentrations of iodinated contrast medium. A comparison between the theoretical values of Z eff and that provided by the manufacturer was performed. The measured and theoretical monochromatic CT numbers at 40-130 keV were compared. The average difference between the Z eff values of lung (inhale) inserts in the tissue characterization phantom was 81.3% and the average Z eff difference was within 8.4%. The average difference between the Z eff values of the varying concentrations of iodinated contrast medium was within 11.2%. For the varying concentrations of iodinated contrast medium, the differences between the measured and theoretical monochromatic CT values increased with decreasing monochromatic energy. The Z eff and monochromatic CT numbers in the tissue characterization phantom were reasonably accurate. The accuracy of the raw-data-based Z eff values was higher than that of image-based Z eff values in the tissue-equivalent phantom. The accuracy of Z eff values in the contrast medium was in good agreement within the maximum SD found in the iodine concentration range of clinical dynamic CT imaging. Moreover, the optimum monochromatic energy for human tissue and iodinated contrast medium was found to be 70 keV. Advances in knowledge: The accuracy of the Z eff values and monochromatic CT numbers of the contrast medium created by raw-data-based, dual-energy CT could be sufficient in clinical conditions.
Zeng, Rong; Greenfield, Patricia M
2015-02-01
Chinese people have held collectivistic values such as obligation, giving to other people, obedience and sacrifice of personal interests for thousands of years. In recent decades, China has undergone rapid economic development and urbanisation. This study investigates changing cultural values in China from 1970 to 2008 and the relationship of changing values to ecological shifts. The conceptual framework for the study was Greenfield's (2009) theory of social change and human development. Changing frequencies of contrasting Chinese words indexing individualistic or collectivistic values show that values shift along with ecological changes (urbanisation, economic development and enrollment in higher education), thereby adapting to current sociodemographic contexts. Words indexing adaptive individualistic values increased in frequency between 1970 and 2008. In contrast, words indexing less adaptive collectivistic values either decreased in frequency in this same period of time or else rose more slowly than words indexing contrasting individualistic values. © 2015 International Union of Psychological Science.
Multimodal Medical Image Fusion by Adaptive Manifold Filter.
Geng, Peng; Liu, Shuaiqi; Zhuang, Shanna
2015-01-01
Medical image fusion plays an important role in diagnosis and treatment of diseases such as image-guided radiotherapy and surgery. The modified local contrast information is proposed to fuse multimodal medical images. Firstly, the adaptive manifold filter is introduced into filtering source images as the low-frequency part in the modified local contrast. Secondly, the modified spatial frequency of the source images is adopted as the high-frequency part in the modified local contrast. Finally, the pixel with larger modified local contrast is selected into the fused image. The presented scheme outperforms the guided filter method in spatial domain, the dual-tree complex wavelet transform-based method, nonsubsampled contourlet transform-based method, and four classic fusion methods in terms of visual quality. Furthermore, the mutual information values by the presented method are averagely 55%, 41%, and 62% higher than the three methods and those values of edge based similarity measure by the presented method are averagely 13%, 33%, and 14% higher than the three methods for the six pairs of source images.
Roessler, Ann-Christin; Hupfer, Martin; Kolditz, Daniel; Jost, Gregor; Pietsch, Hubertus; Kalender, Willi A
2016-04-01
Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.
Am I a 6 or a 10? Mate Value Among Young Adult Survivors of Childhood Cancer and Healthy Peers.
Lehmann, Vicky; Tuinman, Marrit A; Keim, Madelaine C; Hagedoorn, Mariët; Gerhardt, Cynthia A
2018-02-01
This study focused on self-perceived mate value of young adult survivors of childhood cancer relative to healthy peers. Qualitative studies indicate potential problems surrounding romantic relationships among survivors, but systematic studies are missing. One-hundred forty-nine childhood cancer survivors and 149 matched controls completed online questionnaires about their mate value, social comparison strategies (i.e., upward/downward identifying/contrasting strategies), and marital status. Survivors and controls were aged 20-40 (M = 27.8), 55% were female, and survivors had been treated for brain tumors (n = 52; 35%), leukemia (n = 42; 28%), lymphoma (n = 31; 21%), or other solid tumors (n = 24; 16%) at 5-33 years before study participation. Survivors and controls did not differ on overall mate value, but on individual characteristics: Survivors thought they had a better sense of humor (d = 0.36), were more loyal (d = 0.32), had higher social status (d = 0.26), and were more ambitious (d = 0.19), while also considering themselves less sexually adventurous (d = 0.31), less healthy (d = 0.26), having less desire to have children (d = 0.21), and a less attractive face (d = 0.20). Higher mate value was related to being partnered, more upward-identifying, less upward-contrasting, and less downward-identifying strategies. Moreover, less downward-identifying was associated with higher mate value in survivors, but not controls; whereas greater downward-contrasting was associated with higher mate value among controls only (R 2 = 30.8%). Survivors do not generally view themselves as less valuable (potential) romantic partners, but they evaluate different characteristics either more positively or more negatively. Social comparison strategies offer targetable points of interventions to intervene on negative self-evaluations, potentially enhancing well-being.
Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut
2006-01-01
Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.
Less Is Sometimes More: Goal Content Matters
ERIC Educational Resources Information Center
Vansteenkiste, Maarten; Simons, Joke; Lens, Willy; Soenens, Bart; Matos, Lennia; Lacante, Marlies
2004-01-01
According to expectancy-value theories, increasing the utility value of a learning activity should result in higher motivation and better learning. In contrast, self-determination theory posits that the content of the future goals (intrinsic vs. extrinsic) that enhance the utility value of the learning activity needs to be considered as well.…
NASA Astrophysics Data System (ADS)
Venkatesha, N.; Poojar, Pavan; Geethanath, Sairam; Srivastava, Chandan
2014-12-01
Production of bio-compatible contrast agent materials to enhance the sensitivity of the magnetic resonance imaging (MRI) technique is a highly active area in MRI related research. This work illustrates the potential of a new material: graphene oxide-gadolinium (III) oxide nanoparticle (GO-Gd2O3) composite in yielding both transverse (16.3 mM-1 s-1) and longitudinal relaxivity (40 mM-1 s-1) values which are significantly higher than the proton relaxivity values achieved using the gadolinium based contrast agents currently used in MRI. Such high proton relaxivity values can facilitate low dosage of GO-Gd2O3 composite for obtaining both T1 and T2 weighted high signal-to-noise ratio images in MRI.
NASA Astrophysics Data System (ADS)
Yang, Lijiao; Zhou, Zijian; Liu, Hanyu; Wu, Changqiang; Zhang, Hui; Huang, Guoming; Ai, Hua; Gao, Jinhao
2015-04-01
Magnetic resonance imaging (MRI) contrast agents with both positive (T1) and negative (T2) contrast abilities are needed in clinical diagnosis for fault-free accurate detection of lesions. We report a facile synthesis of europium-engineered iron oxide (EuIO) nanocubes as T1 and T2 contrast agents for MRI in living subjects. The Eu(iii) oxide-embedded iron oxide nanoparticles significantly increase the T1 relaxivity with an enhanced positive contrast effect. EuIO nanocubes with 14 nm in diameter showed a high r1 value of 36.8 mM-1 s-1 with respect to total metal ions (Fe + Eu), which is about 3 times higher than that of Fe3O4 nanoparticles with similar size. Moreover, both r1 and r2 values of EuIO nanocubes can be tuned by varying their sizes and Eu doping ratios. After citrate coating, EuIO nanocubes can provide enhanced T1 and T2 contrast effects in small animals, particularly in the cardiac and liver regions. This work may provide an insightful strategy to design MRI contrast agents with both positive and negative contrast abilities for biomedical applications.Magnetic resonance imaging (MRI) contrast agents with both positive (T1) and negative (T2) contrast abilities are needed in clinical diagnosis for fault-free accurate detection of lesions. We report a facile synthesis of europium-engineered iron oxide (EuIO) nanocubes as T1 and T2 contrast agents for MRI in living subjects. The Eu(iii) oxide-embedded iron oxide nanoparticles significantly increase the T1 relaxivity with an enhanced positive contrast effect. EuIO nanocubes with 14 nm in diameter showed a high r1 value of 36.8 mM-1 s-1 with respect to total metal ions (Fe + Eu), which is about 3 times higher than that of Fe3O4 nanoparticles with similar size. Moreover, both r1 and r2 values of EuIO nanocubes can be tuned by varying their sizes and Eu doping ratios. After citrate coating, EuIO nanocubes can provide enhanced T1 and T2 contrast effects in small animals, particularly in the cardiac and liver regions. This work may provide an insightful strategy to design MRI contrast agents with both positive and negative contrast abilities for biomedical applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr00774g
Saito, Kazuhiro; Yoshimura, Nobutaka; Shirota, Natsuhiko; Saguchi, Toru; Sugimoto, Katsutoshi; Tokuuye, Koichi
2016-10-01
The aim of this study to evaluate the effectiveness of enhanced diffusion-weighted imaging (DWI) for distinguishing liver haemangiomas from metastatic tumours (mets). This study included 23 patients with 27 haemangiomas and 26 patients with 46 mets. Breath-holding diffusion-weighted imaging (DWI) (b-values of 0, 50, 100, 150, 200, 400 and 800 s/mm 2 ) were obtained before and 20 min after injection of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Lesion contrast-to-noise ratios (CNRs) were calculated. The data were processed using the bi-exponential model of intravoxel incoherent motion (IVIM). Receiver operating characteristic analysis was performed to compare the diagnostic performance when distinguishing haemangioma from mets. The CNRs of haemangioma and mets at post-contrast enhancement increased. All IVIM parameters for liver haemangioma and mets showed no significant differences between pre- and post-contrast enhancement. The highest A z value of CNR and IVIM parameters occurred at a post-contrast b-value of 0 s/mm 2 and true diffusion (D). The highest qualitative evaluation occurred at a b-value of 800 s/mm 2 . The sensitivity and specificity, with a CNR of 100 or higher at a post-contrast b-value of 0 s/mm 2 and considered to be haemangioma, were 89% and 67% (<10 mm, 91%, 77%) respectively. The sensitivity and specificity, when D was higher than 1.4 × 10 -3 mm 2 /s, were 74% and 83% (<10 mm, 64%, 77%) respectively. The sensitivity and specificity of qualitative evaluation by enhanced DWI were 74% and 76% (<10 mm, 64%, 80%) respectively. The accuracy of the CNR was highest with b = 0; however, examination at high b-values had advantages in the qualitative evaluation of some small-size lesions. © 2016 The Royal Australian and New Zealand College of Radiologists.
Weatherly, Jeffrey N; Nurnberger, Jeri T; Hanson, Brent C
2005-08-31
Previous studies have demonstrated that consumption of a low-valued food substance may decrease if access to a high-valued substance will soon be available (negative anticipatory contrast). Research has also demonstrated that responding for a low-valued reinforcer may increase if responding for a high-valued reinforcer will soon be possible (positive induction). The present experiment employed rats to respond in a procedure similar to that typically used to produce negative anticipatory contrast. The goal was to determine what factors contribute to when a contrast or an induction effect will occur. Based on previous research, the influence of auditory cues, temporal delays, food deprivation, and location of substance delivery were investigated. Auditory cues and temporal delays did little to influence whether subjects increased or decreased their consumption of 1% sucrose when access to 32% sucrose was upcoming. The appearance of contrast or induction was related to level of deprivation, with deprivation promoting induction. Which effect occurred also depended on whether subjects consumed the two substances from one spout in one location (induction) or from two different spouts in two different locations (contrast). The present results help identify the procedural link(s) between these two effects. They also provide insight to why positive induction may occur (i.e., higher-order place conditioning).
Higher order aberrations and relative risk of symptoms after LASIK.
Sharma, Munish; Wachler, Brian S Boxer; Chan, Colin C K
2007-03-01
To understand what level of higher order aberrations increases the relative risk of visual symptoms in patients after myopic LASIK. This study was a retrospective comparative analysis of 103 eyes of 62 patients divided in two groups, matched for age, gender, pupil size, and spherical equivalent refraction. The symptomatic group comprised 36 eyes of 24 patients after conventional LASIK with different laser systems evaluated in our referral clinic and the asymptomatic control group consisted of 67 eyes of 38 patients following LADARVision CustomCornea wavefront LASIK. Comparative analysis was performed for uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), contrast sensitivity, refractive cylinder, and higher order aberrations. Wavefront analysis was performed with the LADARWave aberrometer at 6.5-mm analysis for all eyes. Blurring of vision was the most common symptom (41.6%) followed by double image (19.4%), halo (16.7%), and fluctuation in vision (13.9%) in symptomatic patients. A statistically significant difference was noted in UCVA (P = .001), BSCVA (P = .001), contrast sensitivity (P < .001), and manifest cylinder (P = .001) in the two groups. The percentage difference between the symptomatic and control group mean root-mean-square (RMS) values ranged from 157% to 206% or 1.57 to 2.06 times greater. Patients with visual symptoms after LASIK have significantly lower visual acuity and contrast sensitivity and higher mean RMS values for higher order aberrations than patients without symptoms. Root-mean-square values of greater than two times the normal after-LASIK population for any given laser platform may increase the relative risk of symptoms.
CO2 microbubble contrast enhancement in x-ray angiography.
Kariya, S; Komemushi, A; Nakatani, M; Yoshida, R; Sawada, S; Tanigawa, N
2013-04-01
To demonstrate that carbon dioxide (CO2) microbubble contrast enhancement depicts blood vessels when used for x-ray examinations. Microbubbles were generated by cavitation of physiological saline to which CO2 gas had been added using an ejector-type microbubble generator. The input pressure values for CO2 gas and physiological saline that produced a large quantity of CO2 microbubbles were obtained in a phantom. In an animal study, angiography was performed in three swine using three types of contrast: CO2 microbubbles, conventional CO2 gas, and iodinated contrast medium. For CO2 microbubble contrast enhancement, physiological saline, and CO2 gas were supplied at the input pressures calculated in the phantom experiment. Regions of interest were set in the abdominal aorta, external iliac arteries, and background. The difference in digital values between each artery and the background was calculated. The input pressures obtained in the phantom experiment were 0.16 MPa for physiological saline and 0.5 MPa for CO2 gas, with physiological saline input volume being 8.1 ml/s. Three interventional radiologists all evaluated the depictions of all arteries as "present" in the CO2 microbubble contrast enhancement, conventional CO2 contrast enhancement, and iodinated contrast enhancement performed in three swine. Digital values for all vessels with microbubble CO2 contrast enhancement were higher than background values. In x-ray angiography, blood vessels can be depicted by CO2 microbubble contrast enhancement, in which a large quantity of CO2 microbubbles is generated within blood vessels. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
T2 values of articular cartilage in clinically relevant subregions of the asymptomatic knee.
Surowiec, Rachel K; Lucas, Erin P; Fitzcharles, Eric K; Petre, Benjamin M; Dornan, Grant J; Giphart, J Erik; LaPrade, Robert F; Ho, Charles P
2014-06-01
In order for T2 mapping to become more clinically applicable, reproducible subregions and standardized T2 parameters must be defined. This study sought to: (1) define clinically relevant subregions of knee cartilage using bone landmarks identifiable on both MR images and during arthroscopy and (2) determine healthy T2 values and T2 texture parameters within these subregions. Twenty-five asymptomatic volunteers (age 18-35) were evaluated with a sagittal T2 mapping sequence. Manual segmentation was performed by three raters, and cartilage was divided into twenty-one subregions modified from the International Cartilage Repair Society Articular Cartilage Mapping System. Mean T2 values and texture parameters (entropy, variance, contrast, homogeneity) were recorded for each subregion, and inter-rater and intra-rater reliability was assessed. The central regions of the condyles had significantly higher T2 values than the posterior regions (P < 0.05) and higher variance than the posterior region on the medial side (P < 0.001). The central trochlea had significantly greater T2 values than the anterior and posterior condyles. The central lateral plateau had lower T2 values, lower variance, higher homogeneity, and lower contrast than nearly all subregions in the tibia. The central patellar regions had higher entropy than the superior and inferior regions (each P ≤ 0.001). Repeatability was good to excellent for all subregions. Significant differences in mean T2 values and texture parameters were found between subregions in this carefully selected asymptomatic population, which suggest that there is normal variation of T2 values within the knee joint. The clinically relevant subregions were found to be robust as demonstrated by the overall high repeatability.
Novel analytical approach for strongly coupled waveguide arrays
NASA Astrophysics Data System (ADS)
Kohli, Niharika; Srivastava, Sangeeta; Sharma, Enakshi K.
2018-02-01
Coupled Mode theory and Variational methods are the most extensively used analytical methods for the study of coupled optical waveguides. In this paper we have discussed a variation of the Ritz Galerkin Variational method (RGVM) wherein the trial field is a superposition of an orthogonal basis set which in turn is generated from superposition of the individual waveguide modal fields using Gram Schmidt Orthogonalization Procedure (GSOP). The conventional coupled mode theory (CCMT), a modified coupled mode theory (MCMT) incorporating interaction terms that are neglected in CCMT, and an RGVM using orthogonal basis set (RG-GSOP) are compared for waveguide arrays of different materials. The exact effective indices values for these planar waveguide arrays are also studied. The different materials have their index-contrasts ranging between the GaAs/ AlGaAs system to Si/SiO2 system. It has been shown that the error in the effective indices values obtained from MCMT and CCMT is higher than RGVM-GSOP especially in the case of higher index-contrast. Therefore, for accurate calculations of the modal characteristics of planar waveguide arrays, even at higher index-contrasts, RGVM-GSOP is the best choice. Moreover, we obtain obviously orthogonal supermode fields and Hermitian matrix from RGVM-GSOP.
Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain
2017-12-01
To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.
Okunade, Akintunde A.
2007-01-01
In order to achieve uniformity in radiological imaging, it is recommended that the concept of equivalence in shape (quality) and size (quantity) of clinical Xray beams should be used for carrying out the comparative evaluation of image and patient dose. When used under the same irradiation geometry, X-ray beams that are strictly or relatively equivalent in terms of shape and size will produce identical or relatively identical image quality and patient dose. Simple mathematical models and software program EQSPECT.FOR were developed for the comparative evaluation of the performance characteristics in terms of contrast (C), contrast to noise ratio (CNR) and figure-of-merit (FOM = CNR2/DOSE) for spectrally equivalent beams transmitted through filter materials referred to as conventional and k-edged. At the same value of operating potential (kVp), results show that spectrally equivalent beam transmitted through conventional filter with higher atomic number (Z-value) in comparison with that transmitted through conventional filter with lower Z-value resulted in the same value of C and FOM. However, in comparison with the spectrally equivalent beam transmitted through filter of lower Z-value, the beam through filter of higher Z-value produced higher value of CNR and DOSE at equal tube loading (mAs) and kVp. Under the condition of equivalence of spectrum, at scaled (or reduced) tube loading and same kVp, filter materials of higher Z-value can produce the same values of C, CNR, DOSE and FOM as filter materials of lower Z-value. Unlike the case of comparison of spectrally equivalent beam transmitted through one conventional filter and that through another conventional filter, it is not possible to derive simple mathematical formulations for the relative performance of spectrally equivalent beam transmitted through a given conventional filter material and that through kedge filter material. PMID:21224928
Vogt, Florian M; Theysohn, Jens M; Michna, Dariusz; Hunold, Peter; Neudorf, Ulrich; Kinner, Sonja; Barkhausen, Jörg; Quick, Harald H
2013-09-01
To evaluate time-resolved interleaved stochastic trajectories (TWIST) contrast-enhanced 4D magnetic resonance angiography (MRA) and compare it with 3D FLASH MRA in patients with congenital heart and vessel anomalies. Twenty-six patients with congenital heart and vessel anomalies underwent contrast-enhanced MRA with both 3D FLASH and 4D TWIST MRA. Images were subjectively evaluated regarding total image quality, artefacts, diagnostic value and added diagnostic value of 4D dynamic imaging. Quantitative comparison included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness measurements. Three-dimensional FLASH MRA was judged to be significantly better in terms of image quality (4.0 ± 0.6 vs 3.4 ± 0.6, P < 0.05) and artefacts (3.8 ± 0.4 vs 3.3 ± 0.5, P < 0.05); no difference in diagnostic value was found (4.2 ± 0.4 vs 4.0 ± 0.4); important additional functional information was found in 21/26 patients. SNR and CNR were higher in the pulmonary trunk in 4D TWIST, but slightly higher in the systemic arteries in 3D FLASH. No difference in vessel sharpness delineation was found. Although image quality was inferior compared with 3D FLASH MRA, 4D TWIST MRA yields robust images and added diagnostic value through dynamic acquisition was found. Thus, 4D TWIST MRA is an attractive alternative to 3D FLASH MRA. • New magnetic resonance angiography (MRA) techniques are increasingly introduced for congenital cardiovascular problems. • Time-resolved angiography with interleaved stochastic trajectories (TWIST) is an example. • Four-dimensional TWIST MRA provided inferior image quality compared to 3D FLASH MRA but without significant difference in vessel sharpness. • Four-dimensional TWIST MRA gave added diagnostic value.
Rebière, Marilou; Verburg, Frederik A; Palmowski, Moritz; Krohn, Thomas; Pietsch, Hubertus; Kuhl, Christiane K; Mottaghy, Felix M; Behrendt, Florian F
2012-08-01
To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3mg/s) and total iodine load (44.4g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Arterial contrast enhancement was significantly higher for the 300mg/ml contrast medium compared to 370mgI/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P<0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P<0.001). No differences in tracer uptake were found between the contrast media (all P>0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Social Equity and the Assemblage of Values in Australian Higher Education
ERIC Educational Resources Information Center
Rizvi, Fazal; Lingard, Bob
2011-01-01
The paper argues that the policy concept of social equity cannot be adequately understood in a generalised abstract manner, but is better viewed as an assemblage that brings together a number of contrasting, and sometimes competing, values. Our use of assemblage is somewhat eclectic and is designed to underscore the performative character of…
ERIC Educational Resources Information Center
Barron, Gary R. S.
2017-01-01
University rankings have been widely criticized and examined in terms of the environment they create for universities. In this paper, I reverse the question by examining how ranking organizations have responded to criticisms. I contrast ranking values and evaluation with those practiced by academic communities. I argue that the business of ranking…
ERIC Educational Resources Information Center
Robinson, Denise
2012-01-01
This paper seeks to illuminate the crucial and contradictory features of Higher Education (HE) in Further Education (FE) student experience as seen through students' perceptions. The empirical study of Foundation degree (Fd) students studying in FE Colleges using a critical hermeneutics approach, raises a contrasting perspective on the HE in FE…
Assessment of the impact of modeling axial compression on PET image reconstruction.
Belzunce, Martin A; Reader, Andrew J
2017-10-01
To comprehensively evaluate both the acceleration and image-quality impacts of axial compression and its degree of modeling in fully 3D PET image reconstruction. Despite being used since the very dawn of 3D PET reconstruction, there are still no extensive studies on the impact of axial compression and its degree of modeling during reconstruction on the end-point reconstructed image quality. In this work, an evaluation of the impact of axial compression on the image quality is performed by extensively simulating data with span values from 1 to 121. In addition, two methods for modeling the axial compression in the reconstruction were evaluated. The first method models the axial compression in the system matrix, while the second method uses an unmatched projector/backprojector, where the axial compression is modeled only in the forward projector. The different system matrices were analyzed by computing their singular values and the point response functions for small subregions of the FOV. The two methods were evaluated with simulated and real data for the Biograph mMR scanner. For the simulated data, the axial compression with span values lower than 7 did not show a decrease in the contrast of the reconstructed images. For span 11, the standard sinogram size of the mMR scanner, losses of contrast in the range of 5-10 percentage points were observed when measured for a hot lesion. For higher span values, the spatial resolution was degraded considerably. However, impressively, for all span values of 21 and lower, modeling the axial compression in the system matrix compensated for the spatial resolution degradation and obtained similar contrast values as the span 1 reconstructions. Such approaches have the same processing times as span 1 reconstructions, but they permit significant reduction in storage requirements for the fully 3D sinograms. For higher span values, the system has a large condition number and it is therefore difficult to recover accurately the higher frequencies. Modeling the axial compression also achieved a lower coefficient of variation but with an increase of intervoxel correlations. The unmatched projector/backprojector achieved similar contrast values to the matched version at considerably lower reconstruction times, but at the cost of noisier images. For a line source scan, the reconstructions with modeling of the axial compression achieved similar resolution to the span 1 reconstructions. Axial compression applied to PET sinograms was found to have a negligible impact for span values lower than 7. For span values up to 21, the spatial resolution degradation due to the axial compression can be almost completely compensated for by modeling this effect in the system matrix at the expense of considerably larger processing times and higher intervoxel correlations, while retaining the storage benefit of compressed data. For even higher span values, the resolution loss cannot be completely compensated possibly due to an effective null space in the system. The use of an unmatched projector/backprojector proved to be a practical solution to compensate for the spatial resolution degradation at a reasonable computational cost but can lead to noisier images. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Garcia-Comas, C.; Chiba, S.; Sugisaki, H.; Hashioka, T.; Smith, S. L.
2016-02-01
Understanding how species coexist in rich communities and the role of biodiversity on ecosystem-functioning is a long-standing challenge in ecology. Comparing functional diversity to species diversity may shed light on these questions. Here, we analyze copepod species data from the ODATE collection: 3142 samples collected over a period of 40 years, which includes a 10 o x 10o area of the Oyashio-Kuroshio Transition System, east of Japan (western North Pacific). The area hosts species characteristic of subarctic and subtropical communities. 163 copepod species were classified into five categorical functional traits (i.e., size, food, reproduction, thermal affinity and coastal-offshore habitat), following online databases and local taxonomic keys. We observe a general opposite hump-shaped relationship of species evenness (lower at mid-point) and functional diversity (Rao's Q) (higher at mid-point) with species richness. Subtropical Kuroshio communities tend to be richer with higher species evenness, and yet subarctic and transition waters tend to host communities of higher functional diversity. The distribution of trait values within each functional trait was further examined in relation to the Species Abundances Distribution (SAD). In subtropical communities, the distribution of trait values in the species ranking is homogenous, mirroring the frequency of those trait values in the entire community. In contrast, in subarctic communities the distribution of trait values differs along the species rank, with dominant species having favorable trait values more often than expected by chance (i.e., based on the overall frequency of that trait value in the entire community). Our results suggest that subtropical communities may be niche-saturated towards the most adapted trait values, so that merely having the most adapted trait value confers no strong competitive advantage to a species.
Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita
2017-11-01
Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P < .001 for all results). In addition, contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed breast cancer, with a higher PPV. © RSNA, 2017.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, C; Yin, Y
Purpose: The purpose of this research is investigating which texture features extracted from FDG-PET images by gray-level co-occurrence matrix(GLCM) have a higher prognostic value than the other texture features. Methods: 21 non-small cell lung cancer(NSCLC) patients were approved in the study. Patients underwent 18F-FDG PET/CT scans with both pre-treatment and post-treatment. Firstly, the tumors were extracted by our house developed software. Secondly, the clinical features including the maximum SUV and tumor volume were extracted by MIM vista software, and texture features including angular second moment, contrast, inverse different moment, entropy and correlation were extracted using MATLAB.The differences can be calculatedmore » by using post-treatment features to subtract pre-treatment features. Finally, the SPSS software was used to get the Pearson correlation coefficients and Spearman rank correlation coefficients between the change ratios of texture features and change ratios of clinical features. Results: The Pearson and Spearman rank correlation coefficient between contrast and SUV maximum is 0.785 and 0.709. The P and S value between inverse difference moment and tumor volume is 0.953 and 0.942. Conclusion: This preliminary study showed that the relationships between different texture features and the same clinical feature are different. Finding the prognostic value of contrast and inverse difference moment were higher than the other three textures extracted by GLCM.« less
Fujiwara, Yasuhiro; Maruyama, Hirotoshi; Toyomaru, Kanako; Nishizaka, Yuri; Fukamatsu, Masahiro
2018-06-01
Magnetic resonance imaging (MRI) is widely used to detect carotid atherosclerotic plaques. Although it is important to evaluate vulnerable carotid plaques containing lipids and intra-plaque hemorrhages (IPHs) using T 1 -weighted images, the image contrast changes depending on the imaging settings. Moreover, to distinguish between a thrombus and a hemorrhage, it is useful to evaluate the iron content of the plaque using both T 1 -weighted and T 2 *-weighted images. Therefore, a quantitative evaluation of carotid atherosclerotic plaques using T 1 and T 2 * values may be necessary for the accurate evaluation of plaque components. The purpose of this study was to determine whether the multi-echo phase-sensitive inversion recovery (mPSIR) sequence can improve T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of an IPH. T 1 and T 2 * values measured using mPSIR were compared to values from conventional methods in phantom and in vivo studies. In the phantom study, the T 1 and T 2 * values estimated using mPSIR were linearly correlated with those of conventional methods. In the in vivo study, mPSIR demonstrated higher T 1 contrast between the IPH phantom and sternocleidomastoid muscle than the conventional method. Moreover, the T 1 and T 2 * values of the blood vessel wall and sternocleidomastoid muscle estimated using mPSIR were correlated with values measured by conventional methods and with values reported previously. The mPSIR sequence improved T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of the neck region. Although further study is required to evaluate the clinical utility, mPSIR may improve carotid atherosclerotic plaque detection and provide detailed information about plaque components.
Mazaheri, Yousef; Hötker, Andreas M; Shukla-Dave, Amita; Akin, Oguz; Hricak, Hedvig
2018-09-01
To determine whether water diffusion and the perfusion fraction coefficients in prostate peripheral zone (PZ) and prostate cancer (PCa) are affected by intravenous contrast injection and explore the potential mechanism behind previously reported differences between pre- and post-contrast ADC values. Our institutional review board waived informed consent for this HIPAA-compliant, retrospective study, which included 32 patients (median age, 63 years; range, 47-77 years) with biopsy-proven, untreated PCa who underwent 3-Tesla MRI, including DW-MRI at b-values 0, 400, 700, 1000 s/mm 2 before and after gadolinium injection. For regions of interest (ROIs) in presumed benign PZ and PZ PCa, apparent diffusion coefficient (ADC), perfusion fraction f, and diffusion coefficient D were estimated voxel-wise, and signal-to-noise ratio (SNR) and contrast-to-noise (CNR) were estimated. Pre- and post-contrast measurements were compared by Wilcoxon signed-rank test; P < 0.05 was considered significant. In PZ, f (P = 0.002) was significantly higher on post-contrast imaging than on pre-contrast imaging, but ADC and D values did not change significantly (P = 0.562 and 0.295 respectively). In PCa, all parameters differed significantly between post-contrast and pre-contrast imaging (P < 0.0001 for ADC, P = 0.0084 for D, and P = 0.029 for f). On post-contrast imaging, SNR was not significantly different in PZ (P = 0.260) but was significantly lower in PCa (P < 0.0001); CNR did not change significantly (P = 0.059). After contrast injection, ADC and D declined significantly in PCa only, while f increased significantly in both PCa and PZ. Pre- and post-contrast diffusion parameters cannot be used interchangeably for diagnostic purposes that require quantitative diffusion estimates. Copyright © 2018. Published by Elsevier Inc.
ERIC Educational Resources Information Center
Davidovitch, Nitza; Soen, Dan
2015-01-01
Civic studies in Israel and elsewhere are unlike any other school subject. This course of study has a higher purpose--to transform students into good citizens. In contrast to other core subjects, civics, in essence, strives to realize ethical goals. While other subjects perceive the instilling of values as a secondary outcome, in civics the…
Young children's preference for unique owned objects.
Gelman, Susan A; Davidson, Natalie S
2016-10-01
An important aspect of human thought is the value we place on unique individuals. Adults place higher value on authentic works of art than exact replicas, and young children at times value their original possessions over exact duplicates. What is the scope of this preference in early childhood, and when do children understand its subjective nature? On a series of trials, we asked three-year-olds (N=36) to choose between two toys for either themselves or the researcher: an old (visibly used) toy vs. a new (more attractive) toy matched in type and appearance (e.g., old vs. brand-new blanket). Focal pairs contrasted the child's own toy with a matched new object; Control pairs contrasted toys the child had never seen before. Children preferred the old toys for Focal pairs only, and treated their own preferences as not shared by the researcher. By 3years of age, young children place special value on unique individuals, and understand the subjective nature of that value. Copyright © 2016 Elsevier B.V. All rights reserved.
Young Children's Preference for Unique Owned Objects
Gelman, Susan A.; Davidson, Natalie S.
2016-01-01
An important aspect of human thought is the value we place on unique individuals. Adults place higher value on authentic works of art than exact replicas, and young children at times value their original possessions over exact duplicates. What is the scope of this preference in early childhood, and when do children understand its subjective nature? On a series of trials, we asked three-year-olds (N=36) to choose between two toys for either themselves or the researcher: an old (visibly used) toy versus a new (more attractive) toy matched in type and appearance (e.g., old vs. brand-new blanket). Focal pairs contrasted the child's own toy with a matched new object; Control pairs contrasted toys the child had never seen before. Children preferred the old toys for Focal pairs only, and treated their own preferences as not shared by the researcher. By 3 years of age, young children place special value on unique individuals, and understand the subjective nature of that value. PMID:27395441
Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C
2017-04-01
To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). 68 Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.
Erb-Eigner, Katharina; Taupitz, Matthias; Asbach, Patrick
2016-01-01
The purpose of this study was to compare contrast and image quality of whole-body equilibrium-phase high-spatial-resolution MR angiography using a non-protein-binding unspecific extracellular gadolinium-based contrast medium with that of two contrast media with different protein-binding properties. 45 patients were examined using either 15 mL of gadobutrol (non-protein-binding, n = 15), 32 mL of gadobenate dimeglumine (weakly protein binding, n = 15) or 11 mL gadofosveset trisodium (protein binding, n = 15) followed by equilibrium-phase high-spatial-resolution MR-angiography of four consecutive anatomic regions. The time elapsed between the contrast injection and the beginning of the equilibrium-phase image acquisition in the respective region was measured and was up to 21 min. Signal intensity was measured in two vessels per region and in muscle tissue. Relative contrast (RC) values were calculated. Vessel contrast, artifacts and image quality were rated by two radiologists in consensus on a five-point scale. Compared with gadobutrol, gadofosveset trisodium revealed significantly higher RC values only when acquired later than 15 min after bolus injection. Otherwise, no significant differences between the three contrast media were found regarding vascular contrast and image quality. Equilibrium-phase high-spatial-resolution MR-angiography using a weakly protein-binding or even non-protein-binding contrast medium is equivalent to using a stronger protein-binding contrast medium when image acquisition is within the first 15 min after contrast injection, and allows depiction of the vasculature with high contrast and image quality. The protein-binding contrast medium was superior for imaging only later than 15 min after contrast medium injection. Copyright © 2015 John Wiley & Sons, Ltd.
[Blood lipids and adaptation to stress as risk factors for stroke prevention].
Anders, I; Esterbauer, E; Fink, A; Ladurner, G; Huemer, M; Wranek, U
2000-01-01
Do stroke prevention patients with increased blood-fat-protein compounds (total cholesterol, HDL- and LDL cholesterol and triglyceride) have a different method of coping than patients with normal blood fat? 1159 stroke prevention patients participated in the following stroke risk investigations at this hospital: biographical and risk factor-orientated anamnesis, a neurological status investigation, a laboratory investigation, a sonographic investigation and a psychological investigation. The differences in the coping strategies of those patients with normal and those with higher blood-fat-protein compounds were investigated. Patients with higher total cholesterol showed significantly higher values in the avoidance of stress situations (sig. 0.041) and a stronger tendency towards escapist behaviour (sig. 0.05). Patients with normal HDL cholesterol values indicated a tendency (sig. 0.07) to higher values in positive self-instruction in comparison to patients with reduced HDL cholesterol values. Those prevention patients with higher LDL values showed a tendency (sig. 0.08) to higher values in the intake of narcotic substances (nicotine, alcohol, tranquillisers, pharmaceutical agents). Patients with increased triglyceride indicated significantly higher values in coping by compensation (eating, shopping, reward behaviour, watching TV; sig. 0.037) and the intake of narcotic substances (sig. 0.044). Prevention patients with higher total cholesterol, LDL/HDL, or triglyceride values showed significantly different coping strategies in comparison to those patients with normal values. Increased avoidance and escapism behaviour and also compensation and the abuse of narcotic substances could be seen in connection with an increase in the risk of a stroke. In contrast, a constructive coping strategy such as positive self-instruction could reduce the risk of a stroke, which goes along with normal HDL cholesterol.
Ying, M L; Xiao, W W; Xu, S L; Shu, J E; Pan, J F; Fu, J F; Lu, J H; Pan, Y H; Jiang, Y
2016-11-20
Objective: To investigate the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in the differential diagnosis and blood perfusion evaluation of benign and malignant hepatic lesions. Methods: A retrospective analysis was performed for 86 patients (96 lesions) with pathologically or clinically confirmed hepatic lesions or hepatic lesions diagnosed based on follow-up results, among whom 48 had malignant lesions (53 lesions) and 38 had benign lesions (43 lesions). The patients underwent conventional magnetic resonance (MR) plain scan, contrast-enhanced scan, and diffusion-weighted imaging (DWI) with different b values (b = 0, 50, 100, 150, 200, 400, 600, 800, 1 000, and 1 200 s/mm 2 ) to determine the parameters of the double exponential model for intravoxel incoherent motion (IVIM): fast diffusion coefficient Dfast, slow diffusion coefficient Dslow, and percentage of fast-diffusion constituent F value. The patients were divided into groups according to the blood supply to lesions on conventional MR plain scan and contrast-enhanced scan, and there were 47 lesions in abundant blood supply group and 49 in poor blood supply group. The data for analysis were Dfast, Dslow, and F values of benign/malignant lesion groups and abundant/poor blood supply groups. The independent samples t-test was used for statistical analysis; the independent samples non-parametric test Mann-Whitney U test was used for the comparison of F value; the receiver operating characteristic (ROC) curve was used to evaluate the value of above parameters in the differentiation of benign and malignant lesions and blood supply evaluation. Results: Compared with the malignant lesion group, the benign lesion group had significantly higher Dslow, and F values ( P < 0.001 or P = 0.001) and a higher Dfast value ( P = 0.053). Compared with the poor blood supply group, the abundant blood supply group had significantly higher Dfast and F values ( P < 0.001 or P = 0.001) and a higher Dslow value ( P = 0.185). According to the ROC curve, the cut-off values of Dslow, Dfast, and F values in the diagnosis of benign/malignant hepatic lesions and evaluation of abundant/poor blood supply were 1.18×10 -3 mm 2 /s, 27.20×10 -3 mm 2 /s, 20.25%, 1.17×10 -3 mm 2 /s, 20.30×10 -3 mm 2 /s, and 17.80%, respectively, with sensitivities, specificities, accuracy, and areas under the ROC curve of 90.69%/92.45%/91.66%/0.938, 46.51%/73.58%/61.45%/0.589, 74.41%/50.94%/62.50%/0.653, 59.57%/57.14%/58.33%/0.559, 55.32%/63.26%/59.37%/0.618, and 93.61%/89.79%/90.62%/0.961, respectively. Conclusion: The parameter of the double exponential model for IVIM, Dslow value, has a certain value in the differential diagnosis of benign and malignant hepatic lesions, and F value can show blood perfusion in benign and malignant hepatic lesions without the need for contrast-enhanced scan, which provides a reference for the qualitative diagnosis of liver tumor.
Raimundo, Joana; Vale, Carlos; Martins, Inês; Fontes, Jorge; Graça, Gonçalo; Caetano, Miguel
2015-11-15
Concentrations of V, Cr, Mn, Co, Ni, Cu, Zn, As, Se, Cd and Pb were determined in muscle, liver and gonads of two ecologically contrasting fishes, Helicolenus dactylopterus (benthic) and Pagellus bogaraveo (benthopelagic). Elevated concentrations of As, Se and Cd found in tissues of both species appear to mirror the contribution of volcanic activity to the natural inputs of elements to Azorean waters. Results showed different element accumulation between the two species. Whereas higher concentrations were found in the liver of P. bogaraveo, elevated values were observed in the muscle of H. dactylopterus. Differences in accumulation are most likely related to metabolic rates, diet specificities and habitat. Concentrations in gonads varied up to four orders of magnitude, being higher and more variable in P. bogaraveo than H. dactylopterus. Elevated values of Cd were detected in gonads of both species despite its non-essential role on metabolic functions, presumably related to elimination. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Shuo; Jin, Weiqi; Li, Li; Li, Yiyang
2018-05-01
Infrared thermal images can reflect the thermal-radiation distribution of a particular scene. However, the contrast of the infrared images is usually low. Hence, it is generally necessary to enhance the contrast of infrared images in advance to facilitate subsequent recognition and analysis. Based on the adaptive double plateaus histogram equalization, this paper presents an improved contrast enhancement algorithm for infrared thermal images. In the proposed algorithm, the normalized coefficient of variation of the histogram, which characterizes the level of contrast enhancement, is introduced as feedback information to adjust the upper and lower plateau thresholds. The experiments on actual infrared images show that compared to the three typical contrast-enhancement algorithms, the proposed algorithm has better scene adaptability and yields better contrast-enhancement results for infrared images with more dark areas or a higher dynamic range. Hence, it has high application value in contrast enhancement, dynamic range compression, and digital detail enhancement for infrared thermal images.
Evaluation of neonatal brain myelination using the T1- and T2-weighted MRI ratio.
Soun, Jennifer E; Liu, Michael Z; Cauley, Keith A; Grinband, Jack
2017-09-01
To validate the T1- and T2-weighted (T1w/T2w) MRI ratio technique in evaluating myelin in the neonatal brain. T1w and T2w MR images of 10 term neonates with normal-appearing brain parenchyma were obtained from a single 1.5 Tesla MRI and retrospectively analyzed. T1w/T2w ratio images were created with a postprocessing pipeline and qualitatively compared with standard clinical sequences (T1w, T2w, and apparent diffusion coefficient [ADC]). Quantitative assessment was also performed to assess the ratio technique in detecting areas of known myelination (e.g., posterior limb of the internal capsule) and very low myelination (e.g., optic radiations) using linear regression analysis and the Michelson Contrast equation, a measure of luminance contrast intensity. The ratio image provided qualitative improvements in the ability to visualize regional variation in myelin content of neonates. Linear regression analysis demonstrated a significant inverse relationship between the ratio intensity values and ADC values in the posterior limb of the internal capsule and the optic radiations (R 2 = 0.96 and P < 0.001). The Michelson Contrast equation showed that contrast differences between these two regions for the ratio images were 1.6 times higher than T1w, 2.6 times higher than T2w, and 1.8 times higher than ADC (all P < 0.001). Finally, the ratio improved visualization of the corticospinal tract, one of the earliest myelinated pathways. The T1w/T2w ratio accentuates contrast between myelinated and less myelinated structures and may enhance our diagnostic ability to detect myelination patterns in the neonatal brain. 2 Technical Efficacy: Stage2 J. MAGN. RESON. IMAGING 2017;46:690-696. © 2016 International Society for Magnetic Resonance in Medicine.
Gadolinium-enhanced MR images of the growing piglet skeleton: ionic versus nonionic contrast agent.
Menezes, Nina M; Olear, Elizabeth A; Li, Xiaoming; Connolly, Susan A; Zurakowski, David; Foley, Mary; Shapiro, Frederic; Jaramillo, Diego
2006-05-01
To determine whether there are differences in the distribution of ionic and nonionic gadolinium-based contrast agents by evaluating contrast enhancement of the physis, epiphyseal cartilage, secondary ossification center, and metaphysis in the knees of normal piglets. Following approval from the Subcommittee on Research Animal Care, knees of 12 3-week-old piglets were imaged at 3-T magnetic resonance (MR) imaging after intravenous injection of gadoteridol (nonionic contrast agent; n = 6) or gadopentetate dimeglumine (ionic contrast agent; n = 6). Early enhancement evaluation with gradient-echo MR imaging was quantified and compared (Student t test) by means of enhancement ratios. Distribution of contrast material was assessed and compared (Student t test) by means of T1 measurements obtained before and at three 15-minute intervals after contrast agent administration. The relative visibility of the physis, epiphyseal cartilage, secondary ossification center, and metaphysis was qualitatively assessed by two observers and compared (Wilcoxon signed rank test). Differences in matrix content and cellularity that might explain the imaging findings were studied at histologic evaluation. Enhancement ratios were significantly higher for gadoteridol than for gadopentetate dimeglumine in the physis, epiphyseal cartilage, and secondary ossification center (P < .05). After contrast agent administration, T1 values decreased sharply for both agents-but more so for gadoteridol. Additionally, there was less variability in T1 values across structures with this contrast agent. Gadoteridol resulted in greater visibility of the physis, while gadopentetate dimeglumine resulted in greater contrast between the physis and metaphysis (P < .05). The results suggest different roles for the two gadolinium-based contrast agents: The nonionic contrast medium is better suited for evaluating perfusion and anatomic definition in the immature skeleton, while the ionic contrast medium is better for evaluating cartilage fixed-charge density. (c) RSNA, 2006.
Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu
2015-01-01
To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.
Students' Attitudes toward Socialism, Nationalism, and Perestroika.
ERIC Educational Resources Information Center
McKeehan, Irina V.
1993-01-01
Analyzes the results of sociological surveys conducted among thousands of students in higher education institutions in Russia and other republics of the former Soviet Union. Compares and contrasts student attitudes about such topics as economics, democratic values, ethnic groups, education, and students' perception of the future. (CFR)
Effects of developer exhaustion on DFL Contrast FV-58 and Kodak Insight dental films.
de Carvalho, Fabiano Pachêco; da Silveira, M M F; Frazão, M A G; de Santana, S T; dos Anjos Pontual, M L
2011-09-01
The aim of this study was to compare the properties of the DFL Contrast FV-58 F-speed film (DFL Co., Rio de Janerio, Brazil) with the Kodak Insight E/F speed film (Eastman Kodak, Rochester, NY) in fresh and exhausted processing solutions. The parameters studied were the speed, average gradient and latitude. Five samples of each type of film were exposed under standardized conditions over 5 weeks. The films were developed in fresh and progressively exhausted processing solutions. Characteristic curves were constructed from values of optical density and radiation dose and were used to calculate the parameters. An analysis of variance was performed separately for film type and time. DFL Contrast FV-58 film has a speed and average gradient that is significantly higher than Insight film, whereas the values of latitude are lower. Exhausted processing solutions were not significant in the parameters studied. DFL Contrast FV-58 film has stable properties when exhausted manual processing solutions are used and can be recommended for use in dental practice, contributing to dose reduction.
Effects of developer exhaustion on DFL Contrast FV-58 and Kodak Insight dental films
de Carvalho, FP; da Silveira, MMF; Frazão, MAG; de Santana, ST; dos Anjos Pontual, ML
2011-01-01
Objectives The aim of this study was to compare the properties of the DFL Contrast FV-58 F-speed film (DFL Co., Rio de Janerio, Brazil) with the Kodak Insight E/F speed film (Eastman Kodak, Rochester, NY) in fresh and exhausted processing solutions. The parameters studied were the speed, average gradient and latitude. Methods Five samples of each type of film were exposed under standardized conditions over 5 weeks. The films were developed in fresh and progressively exhausted processing solutions. Characteristic curves were constructed from values of optical density and radiation dose and were used to calculate the parameters. An analysis of variance was performed separately for film type and time. Results DFL Contrast FV-58 film has a speed and average gradient that is significantly higher than Insight film, whereas the values of latitude are lower. Exhausted processing solutions were not significant in the parameters studied. Conclusion DFL Contrast FV-58 film has stable properties when exhausted manual processing solutions are used and can be recommended for use in dental practice, contributing to dose reduction. PMID:21831975
Contrast ratios and masking ability of three types of ceramic veneers.
Chu, Frederick C S; Chow, Tak W; Chai, John
2007-11-01
Although ceramic veneers have been proven to be clinically successful in longevity studies, there is little information on the contrast ratios and masking ability of the available ceramic systems because dental laboratory technology and expensive experimental equipment are required for the investigation. Moreover, the complexity in understanding how to evaluate translucent ceramic materials may also explain why information in this area is limited. The purpose of this study was to determine the contrast ratios and masking abilities of 3 types of all-ceramic veneers by measuring their luminance and color difference over white and black backgrounds. Disk-shaped specimens (8-mm diameter x 0.7-mm thickness) of Shade A2 (Vita Lumin) of 3 types of all-ceramic systems: Procera (n=8), Empress 2 (n=8), and Vitadur Alpha (n=10) were fabricated. The luminance (as Y) and color (as CIE L*a*b*) of the specimens were measured with a colorimeter. The contrast ratio (CR=Yb/Yw), defined as the ratio of illuminance (Y) of the test material when it is placed on the black background (Yb) to the illuminance of the same material when it is placed over a white background (Yw), was determined. The masking ability of a specimen was evaluated by calculating the color difference (DeltaE) of the veneers over white and black backgrounds. Both CR and DeltaE* data were analyzed with 1-way ANOVA and the Tukey HSD test (alpha=.05). The mean contrast ratios (SD) of Procera, Empress 2, and Vitadur Alpha specimens were 0.50 (0.02), 0.46 (0.05), and 0.39 (0.02), respectively. CR values were significantly different among the 3 materials (P<.001). Procera veneers had a significantly higher CR compared to Empress 2 (P=.01) or Vitadur Alpha (P=.01), whereas the CR of Empress 2 was significantly higher than that of Vitadur Alpha (P=.046). Color difference (DeltaE*) (SD) of Procera, Empress 2, and Vitadur Alpha specimens over black and white backgrounds were 24.46 (1.03), 25.80 (1.03), and 31.08 (1.19), respectively. DeltaE* values were statistically different among the 3 materials (P<.001). Vitadur Alpha specimens had significantly higher DeltaE* when compared with Procera (P<.001) or Empress 2 (P<.001), whereas DeltaE* values between Procera and Empress 2 were not significantly different (P=.331). Vitadur Alpha had significantly lower contrast ratio and poorer masking ability compared to Procera or Empress 2. The clinical application of Vitadur Alpha as a veneer material over discolored teeth is cautioned. Although the contrast ratio of Procera was significantly higher than that of Empress 2, the masking abilities of these materials were not significantly different. The clinical application of these 2 ceramics as a veneer material may still be limited when applied over intense tooth discoloration because neither can fully mask the color of a black background.
Phase Contrast Microscopy Analysis of Breast Tissue
Wells, Wendy A.; Wang, Xin; Daghlian, Charles P.; Paulsen, Keith D.; Pogue, Brian W.
2010-01-01
OBJECTIVE To assess how optical scatter properties in breast tissue, as measured by phase contrast microscopy and interpreted pathophysiologically, might be exploited as a diagnostic tool to differentiate cancer from benign tissue. STUDY DESIGN We evaluated frozen human breast tissue sections of adipose tissue, normal breast parenchyma, benign fibroadenoma tumors and noninvasive and invasive malignant cancers by phase contrast microscopy through quantification of grayscale values, using multiple regions of interest (ROI). Student’s t tests were performed on phase contrast measures across diagnostic categories testing data from individual cases; all ROI data were used as separate measures. RESULTS Stroma demonstrated significantly higher scatter intensity than did epithelium, with lower scattering in tumor-associated stroma as compared with normal or benign-associated stroma. Measures were comparable for invasive and noninvasive malignant tumors but were higher than those found in benign tumors and were lowest in adipose tissue. CONCLUSION Significant differences were found in scatter coefficient properties of epithelium and stroma across diagnostic categories of breast tissue, particularly between benign and malignant-associated stroma. Improved understanding of how scatter properties correlate with morphologic criteria used in routine pathologic diagnoses could have a significant clinical impact as developing optical technology allows macroscopic in situ phase contrast imaging. PMID:19736867
Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F
2011-01-01
Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365
Zilkens, Christoph; Miese, Falk; Kim, Young-Jo; Jäger, Marcus; Mamisch, Tallal C; Hosalkar, Harish; Antoch, Gerald; Krauspe, Rüdiger; Bittersohl, Bernd
2014-01-01
To investigate the potential of delayed gadolinium-enhanced magnetic resonance imaging in cartilage (dGEMRIC) after intra-articular (ia) contrast agent administration at 3 Tesla (T), a paired study comparing intravenous (iv) dGEMRIC (standard) with ia-dGEMRIC was performed. Thirty-five symptomatic patients with suspected cartilage damage underwent ia- and iv-dGEMRIC. MRI was performed with a 3T system wherein the interval between both measurements was 2 weeks. For iv-dGEMRIC, FDA approved Gd-DOTA(-) was injected intravenously 45 min before the MRI scan. For ia-dGEMRIC, 10-20 mL of a 2 mM solution of Gd- DOTA(-) was injected under fluoroscopic guidance 30 min before the MRI scan. Both ia- and iv-dGEMRIC demonstrated the typical T1Gd pattern in hip joint cartilage with increasing values toward the superior regions in acetabular cartilage reflecting the higher glycosaminoglycan (GAG) content in the main weight-bearing area. Correlation analysis revealed a moderate correlation between both techniques (r = 0.439, P-value < 0.001), whereas the T1Gd values for iv-dGEMRIC were significantly higher than those for ia-dGEMRIC. This corresponds with the Bland-Altman plot analysis, which revealed a systemic bias (higher T1Gd values after iv gadolinium application) of ∼70 ms. Ia-dGEMRIC was able to reveal the characteristic T1Gd pattern in hip joint cartilage confirming the sensitivity of ia-dGEMRIC for GAG. In addition, there was a significant correlation between iv-dGEMRIC and ia-dGEMRIC. However, the T1Gd values after ia contrast media application were significantly lower than those after iv application that has to be considered for future studies. Copyright © 2013 Wiley Periodicals, Inc.
Invisible Cultural Barriers: Contrasting Perspectives on Student Veterans' Transition
ERIC Educational Resources Information Center
Lim, Jae Hoon; Interiano, Claudia G.; Nowell, Caroline E.; Tkacik, Peter T.; Dahlberg, Jerry L.
2018-01-01
In this interpretative phenomenological study, the implicit cultural values and expectations embedded in faculty/staff's perceptions and how they functioned as a hidden curriculum against student veterans' smooth transition into higher education were analyzed based on in-depth interviews with 20 student veterans and 9 faculty/staff members. By…
Tsurumaru, Daisuke; Miyasaka, Mitsutoshi; Muraki, Toshio; Nishie, Akihiro; Asayama, Yoshiki; Oki, Eiji; Oda, Yoshinao; Honda, Hiroshi
2017-12-01
To evaluate the diagnostic value of contrast-enhanced computed tomography gastrography (CE-CTG) to predict the histological type of gastric cancer. We analyzed 47 consecutive patients with resectable advanced gastric cancer preoperatively evaluated by multiphasic dynamic contrast-enhanced CT. Two radiologists independently reviewed the CT images and they determined the peak enhancement phase, and then measured the CT attenuation value of the gastric lesion for each phase. The histological types of gastric cancers were assigned to three groups as differentiated-type, undifferentiated-type, and mixed-type. We compared the peak enhancement phase of the three types and compared the CT attenuation values in each phase. The peak enhancement was significantly different between the three types of gastric cancers for both readers (reader 1, p=0.001; reader 2, p=0.009); most of the undifferentiated types had peak enhancement in the delayed phase. The CT attenuation values of undifferentiated type were significantly higher than those of differentiated or mixed type in the delayed phase according to both readers (reader 1, p=0.002; reader 2, p=0.004). CE-CTG could provide helpful information in diagnosing the histological type of gastric cancers preoperatively. Copyright © 2017 Elsevier B.V. All rights reserved.
Metlapally, Sangeetha; Tong, Jianliang L.; Tahir, Humza J.; Schor, Clifton M.
2014-01-01
It has been proposed that the accommodation system could perform contrast discrimination between the two dioptric extremes of accommodative microfluctuations to extract directional signals for reflex accommodation. Higher-order aberrations (HOAs) may have a significant influence on the strength of these contrast signals. Our goal was to compute the effect HOAs may have on contrast signals for stimuli within the upper defocus limit by comparing computed microcontrast fluctuations with psychophysical contrast increment thresholds (Bradley & Ohzawa, 1986). Wavefront aberrations were measured while subjects viewed a Maltese spoke stimulus monocularly. Computations were performed for accommodation or disaccommodation stimuli from a 3 Diopter (D) baseline. Microfluctuations were estimated from the standard deviation of the wavefronts over time at baseline. Through-focus Modulation Transfer, optical contrast increments (ΔC), and Weber fractions (ΔC/C) were derived from point spread functions computed from the wavefronts at baseline for 2 and 4 cycles per degree (cpd) components, with and without HOAs. The ΔCs thus computed from the wavefronts were compared with psychophysical contrast increment threshold data. Microfluctuations are potentially useful for extracting directional information for defocus values within 3 D, where contrast increments for the 2 or 4 cpd components exceed psychophysical thresholds. HOAs largely reduce contrast signals produced by microfluctuations, depending on the mean focus error, and their magnitude in individual subjects, and they may shrink the effective stimulus range for reflex accommodation. The upper defocus limit could therefore be constrained by discrimination of microcontrast fluctuations. PMID:25342542
Habets, J; Meijer, T S; Meijer, R C A; Mali, W P Th M; Vonken, E-J P A; Budde, R P J
2012-01-01
Objectives Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions. Methods PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml−1) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml−1). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs. Results Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383–494) and 288±41 Hounsfield units (range 202–367), respectively. Conclusions PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction. PMID:22919014
SANS contrast variation study of magnetoferritin structure at various iron loading
NASA Astrophysics Data System (ADS)
Melnikova, Lucia; Petrenko, Viktor I.; Avdeev, Mikhail V.; Ivankov, Oleksandr I.; Bulavin, Leonid A.; Garamus, Vasil M.; Almásy, László; Mitroova, Zuzana; Kopcansky, Peter
2015-03-01
Magnetoferritin, a synthetic derivate of iron storage protein - ferritin, has been synthesized with different iron oxide loading values. Small-angle neutron scattering experiments were applied to study the structure of magnetoferritin solutions using contrast variation method by varying the light to heavy water ratio of the solvent. Higher iron loading leads to increase of the neutron scattering length density of magnetoferritin and also to the increase of the polydispersity of complexes. The formation of the magnetic core and the variation of the protein shell structure upon iron loading are concluded.
Nations at Risk-- Indicators of Fragility in States Susceptible to Terrorist Attacks
2018-03-01
by the people ” (Fund for Peace, 2014). Conversely, higher values designate a fractious political class unable to overcome the discords of a society ... society and free expression and advocacy” (Fund for Peace, 2014, p. 7). In contrast, high values indicate a high level of group grievance, which leads to...accepted government that fails to represent the entire citizenry. Political structures that are not rooted in the majority of the society , thus lacking
Endo, Tetsuya; Kimura, Osamu; Sato, Rie; Kobayashi, Mari; Matsuda, Ayaka; Matsuishi, Takashi; Haraguchi, Koichi
2014-09-15
We analyzed δ(13)C, δ(15)N and δ(18)O in the muscle and liver from killer whales stranded on the coast of Japan. The δ(15)N values in the muscle samples from calves were apparently higher than those in their lactating mothers, suggesting that nursing may result in the higher δ(15)N values in the muscle samples of calves. The δ(15)N value in the muscle samples of male and female whales, except for the calves, were positively correlated with the δ(13)C values and body length, suggesting that the increases in δ(15)N were due to the growth of the whales and increase in their trophic level. In contrast, the δ(18)O values in the muscle samples of female whales except for the calves were negatively correlated with the δ(13)C and δ(15)N values. The δ(18)O may be lower in whales occupying higher trophic positions (δ(15)N), although it might also be affected by geographic and climatic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Meat and nutritional quality comparison of purebred and crossbred pigs.
Zhang, Jie; Chai, Jie; Luo, Zonggang; He, Hang; Chen, Lei; Liu, Xueqin; Zhou, Qinfei
2018-01-01
Crossbreeding is an effective method of improving the efficiency and profit of production in commercial pig operations. To understand the effect of crossbreeding on meat and nutrient quality, a combination including three purebred (Duroc, D; Landrace, L; Yorkshire, Y) and two crossbred pig lines (Landrace × Yorkshire, LY; Duroc × (Landrace × Yorkshire), DLY) frequently used internationally were studied. The results showed that meat from the LY and DLY crosses had lower values for lightness L24h∗, shear force and epinephrine and higher values for drip loss, C18:1, insulin, glucagon and monounsaturated fatty acids than D, L and Y pigs. Moreover, LY had higher values for post mortem pH and lower values for a* and b* than the purebreds. In contrast, DLY had lower values for pH and higher values for a* and b* than the purebreds. Meat quality-related gene analysis showed that the CAST, IGF2 and MC4R gene expression levels in the LY and DLY pigs were significantly higher than those in the D, L and Y pigs. These results indicate that crossbreeding can alter the meat quality, nutritive value, energy metabolism and gene expression of pigs. Future research should focus on microRNA expression and DNA methylation that regulate gene expression and thus affect the meat quality. © 2017 Japanese Society of Animal Science.
Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh
2016-01-01
Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84-12.82). DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers.
NASA Astrophysics Data System (ADS)
Varvell, K.; Cooper-Sarkar, A. M.; Parker, M. A.; Sansum, R. A.; Aderholz, M.; Armenise, N.; Baton, J. P.; Bullock, F. W.; Berggren, M.; Bertrand, D.; Brisson, V.; Burkot, W.; Calcchio, M.; Claytoh, E. F.; Coghen, T.; Erriquez, O.; Fitch, P. J.; Gerbier, G.; Guy, J.; Hulth, P. O.; Iaselli, G.; Jones, G. T.; Kasper, P.; Klein, H.; Kochowski, C.; Marage, P.; Mermikides, M.; Middleton, R. P.; Morrison, D. R. O.; Mobayyen, M. M.; Natali, S.; Neveu, M.; Nuzzo, S.; O'Neale, S. W.; Petiau, P.; Petrides, A.; Ruggieri, F.; Sacton, J.; Simopoulou, E.; Vallee, C.; Vayaki, A.; Venus, W. A.; Wachsmuth, H.; Wells, J.; Wittek, W.
1987-03-01
The isoscalar nucleon structure functions F 2( x, Q 2) and xF 3( x, Q 2) are measured in the range 0< Q 2<64 GeV2, 1.7< W 2<250 GeV2, x<0.7 using ν andbar v interactions on neon in BEBC. The data are used to evaluate possible higher twist contributions and to determine their impact on the evaluation of the QCD parameter Λ. In contrast to previous analyses reaching to such low W 2 values, it is found that a lowΛ _{overline {MS} } value in the neighbourhood of 100 MeV describes the data adequately and that the contribution of dynamical higher twist effects is small and negative.
Yin, Ping; Xiong, Hua; Liu, Yi; Sah, Shambhu K; Zeng, Chun; Wang, Jingjie; Li, Yongmei; Hong, Nan
2018-01-01
To investigate the application value of using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with extended Tofts linear model for relapsing-remitting multiple sclerosis (RRMS) and its correlation with expanded disability status scale (EDSS) scores and disease duration. Thirty patients with multiple sclerosis (MS) underwent conventional magnetic resonance imaging (MRI) and DCE-MRI with a 3.0 Tesla MR scanner. An extended Tofts linear model was used to quantitatively measure MR imaging biomarkers. The histogram parameters and correlation among imaging biomarkers, EDSS scores, and disease duration were also analyzed. The MR imaging biomarkers volume transfer constant (K trans ), volume of the extravascular extracellular space per unit volume of tissue (Ve), fractional plasma volume (V p ), cerebral blood flow (CBF), and cerebral blood volume (CBV) of contrast-enhancing (CE) lesions were significantly higher (P < 0.05) than those of nonenhancing (NE) lesions and normal-appearing white matter (NAWM) regions. The skewness of Ve value in CE lesions was more close to normal distribution. There was no significant correlation among the biomarkers with the EDSS scores and disease duration (P > 0.05). Our study demonstrates that the DCE-MRI with the extended Tofts linear model can measure the permeability and perfusion characteristic in MS lesions and in NAWM regions. The K trans , Ve, Vp, CBF, and CBV of CE lesions were significantly higher than that of NE lesions. The skewness of Ve value in CE lesions was more close to normal distribution, indicating that the histogram can be helpful to distinguish the pathology of MS lesions.
Kinetic analysis of Legionella inactivation using ozone in wastewater.
Li, Jun; Li, Kunquan; Zhou, Yan; Li, Xuebin; Tao, Tao
2017-02-01
Legionella inactivation using ozone was studied in wastewater using kinetic analysis and modeling. The experimental results indicate that the relationship between the ozone concentration, germ concentration, and chemical oxygen demand (COD) can be used to predict variations in germ and COD concentrations. The ozone reaction with COD and inactivation of Legionella occurred simultaneously, but the reaction with COD likely occurred at a higher rate than the inactivation, as COD is more easily oxidized by ozone than Legionella. Higher initial COD concentrations resulted in a lower inactivation rate and higher lnN/N 0 . Higher temperature led to a higher inactivation efficiency. The relationship of the initial O 3 concentration and Legionella inactivation rate was not linear, and thus, the Ct value required for a 99.99% reduction was not constant. The initial O 3 concentration was more important than the contact time, and a reduction of the initial O 3 concentration could not be compensated by increasing the contact time. The Ct values were compared over a narrow range of initial concentrations; the Ct values could only be contrasted when the initial O 3 concentrations were very similar. A higher initial O 3 concentration led to a higher inflection point value for the lnN/N 0 vs C 0 t curve. Energy consumption using a plasma corona was lower than when using boron-doped diamond electrodes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wilson, Jesse W.; Degan, Simone; Gainey, Christina S.; Mitropoulos, Tanya; Simpson, Mary Jane; Zhang, Jennifer Y.; Warren, Warren S.
2014-01-01
Abstract. We demonstrate a multimodal approach that combines a pump–probe with confocal reflectance and multiphoton autofluorescence microscopy. Pump–probe microscopy has been proven to be of great value in analyzing thin tissue sections of pigmented lesions, as it produces molecular contrast which is inaccessible by other means. However, the higher optical intensity required to overcome scattering in thick tissue leads to higher-order nonlinearities in the optical response of melanin (e.g., two-photon pump and one-photon probe) that present additional challenges for interpreting the data. We show that analysis of pigment composition in vivo must carefully account for signal terms that are nonlinear with respect to the pump and probe intensities. We find that pump–probe imaging gives useful contrast for pigmented structures over a large range of spatial scales (100 μm to 1 cm), making it a potentially useful tool for tracking the progression of pigmented lesions without the need to introduce exogenous contrast agents. PMID:25415567
[Multispiral computed tomographic semiotics of laryngeal cancer].
Vasil'ev, P V; Iudin, A L; Sdvizhkov, A M; Kozhanov, L G
2007-01-01
Multispiral computed tomography (MSCT) with intravenous bolus contrasting is a currently available method for radiodiagnosis of laryngeal cancer. MSCT is of much higher informative value in estimating the extent of a tumorous lesion than the traditional radiodiagnostic techniques: linear tomography, lateral X-ray study, roentgenoscopy and roentgenography of the laryngopharynx and esophagus with barium meal.
NASA Astrophysics Data System (ADS)
Haar, Peter J.; Broaddus, William C.; Chen, Zhi-jian; Fatouros, Panos P.; Gillies, George T.; Corwin, Frank D.
2010-06-01
A common approach to quantify gadolinium (Gd) contrast agents involves measuring the post-contrast change in T1 rate and then using the constant T1 relaxivity R to determine the contrast agent concentration. Because this method is fast and non-invasive, it could be potentially valuable in many areas of brain research. However, to accurately measure contrast agent concentrations in the brain, the T1 relaxivity R of the specific agent must be accurately known. Furthermore, the macromolecular content and compartmentalization of the brain extracellular space (ECS) are expected to significantly alter R from values measured in aqueous solutions. In this study, the T1 relaxivity R of gadolinium-diethylene-triamine penta-acetic acid (Gd-DTPA) was measured following direct interstitial infusions of three different contrast agent concentrations to the parenchyma of rat brains. Changes in magnetic resonance (MR) T1 values were compared to brain slice concentrations determined with inductively coupled plasma atomic emission spectroscopy (ICP-AES) to determine R in 15 rats. Additionally, samples of cerebrospinal fluid, blood and urine were analyzed to evaluate possible Gd-DTPA clearance from the brain. The T1 relaxivity R of Gd-DTPA in the brain ECS was measured to be 5.35 (mM s)-1 in a 2.4 T field. This value is considerably higher than estimations used in studies by other groups. Measurements of brain Gd-DTPA tissue concentrations using MRI and ICP-AES demonstrated a high degree of coincidence. Clearance of Gd-DTPA was minimal at the time point immediately after infusion. These results suggest that the environment of the brain does in fact significantly affect Gd T1 relaxivity, and that MRI can accurately measure contrast agent concentrations when this relaxivity is well characterized.
Zhou, Yunfeng; Wang, Juan; Dassarath, Meera; Wang, Minhong; Zhang, Qiang; Xiong, Yuwei; Yuan, Quan
2015-01-01
To prospectively compare the new computed tomographic angiography (CTA) protocol (NCP) using 80-kV and dual-phase scanning with the routine CTA protocol (RCP) using 120-kV and single-phase scanning in patients with peripheral arterial disease. A total of 60 patients were randomized to undergo the NCP (30 patients) or RCP (30 patients) scan. We compared the arterial attenuation values, overriding of the contrast bolus, signal-to-noise ratio, and radiation dose between 2 groups. The occurrence rate of contrast bolus overriding was not statistically significant (P = 0.69). The average arterial attenuation value in the NCP group was significantly higher (P < 0.05) than that in the RCP group. The radiation dose in the RCP group was significantly higher (P < 0.001) than that in the NCP group. The mean signal-to-noise ratio in the NCP group was significantly lower (P < 0.001). Sixty-four-slice CTA with the NCP can significantly reduce the radiation dose and improve the arterial enhancement and calf arteries imaging.
NASA Astrophysics Data System (ADS)
Paghousi, Roohollah; Fasihi, Kiazand
2018-05-01
We present a new high-contrast controllable switch, which is based on a polystyrene nonlinear cavity, and is implemented in a two dimensional (2D) hole-type photonic crystal (PC). We show that by applying a control signal, the input power can be transmitted to the output waveguide with a high contrast ratio. The operation of the proposed device is investigated through the use of coupled-mode theory (CMT) and finite-difference time-domain (FDTD) method. The contrast ratio of the proposed device varies between 18 and 23, which is higher than the corresponding value in the previous investigations. Based on the simulation results, with increasing the control power the range of operating power will be increased, while the contrast ratio will be decreased. It has been shown that in a modified structure, at the expense of the range of operating power and the contrast ratio, the control power can be decreased, considerably.
NASA Astrophysics Data System (ADS)
Theerasilp, Man; Sunintaboon, Panya; Sungkarat, Witaya; Nasongkla, Norased
2017-11-01
Polymeric micelles of poly(ethylene glycol)- block-poly(ɛ-caprolactone) bearing glucose analog encapsulated with superparamagnetic iron oxide nanoparticles (Glu-SPIO micelles) were synthesized as an MRI contrast agent to target cancer cells based on high-glucose metabolism. Compared to SPIO micelles (non-targeting SPIO micelles), Glu-SPIO micelles demonstrated higher toxicity to human prostate cancer cell lines (PC-3) at high concentration. Atomic absorption spectroscopy was used to determine the amount of iron in cells. It was found that the iron in cancer cells treated by Glu-SPIO micelles were 27-fold higher than cancer cells treated by SPIO micelles at the iron concentration of 25 ppm and fivefold at the iron concentration of 100 ppm. To implement Glu-SPIO micelles as a MR contrast agent, the 3-T clinical MRI was applied to determine transverse relaxivities ( r 2*) and relaxation rate (1/ T 2*) values. In vitro MRI showed different MRI signal from cancer cells after cellular uptake of SPIO micelles and Glu-SPIO micelles. Glu-SPIO micelles was highly sensitive with the r 2* in agarose gel at 155 mM-1 s-1. Moreover, the higher 1/ T 2* value was found for cancer cells treated with Glu-SPIO micelles. These results supported that glucose ligand increased the cellular uptake of micelles by PC-3 cells with over-expressing glucose transporter on the cell membrane. Thus, glucose can be used as a small molecule ligand for targeting prostate cancer cells overexpressing glucose transporter.
Verma, Sadhna; Sarkar, Saradwata; Young, Jason; Venkataraman, Rajesh; Yang, Xu; Bhavsar, Anil; Patil, Nilesh; Donovan, James; Gaitonde, Krishnanath
2016-05-01
The purpose of this study was to compare high b-value (b = 2000 s/mm(2)) acquired diffusion-weighted imaging (aDWI) with computed DWI (cDWI) obtained using four diffusion models-mono-exponential (ME), intra-voxel incoherent motion (IVIM), stretched exponential (SE), and diffusional kurtosis (DK)-with respect to lesion visibility, conspicuity, contrast, and ability to predict significant prostate cancer (PCa). Ninety four patients underwent 3 T MRI including acquisition of b = 2000 s/mm(2) aDWI and low b-value DWI. High b = 2000 s/mm(2) cDWI was obtained using ME, IVIM, SE, and DK models. All images were scored on quality independently by three radiologists. Lesions were identified on all images and graded for lesion conspicuity. For a subset of lesions for which pathological truth was established, lesion-to-background contrast ratios (LBCRs) were computed and binomial generalized linear mixed model analysis was conducted to compare clinically significant PCa predictive capabilities of all DWI. For all readers and all models, cDWI demonstrated higher ratings for image quality and lesion conspicuity than aDWI except DK (p < 0.001). The LBCRs of ME, IVIM, and SE were significantly higher than LBCR of aDWI (p < 0.001). Receiver Operating Characteristic curves obtained from binomial generalized linear mixed model analysis demonstrated higher Area Under the Curves for ME, SE, IVIM, and aDWI compared to DK or PSAD alone in predicting significant PCa. High b-value cDWI using ME, IVIM, and SE diffusion models provide better image quality, lesion conspicuity, and increased LBCR than high b-value aDWI. Using cDWI can potentially provide comparable sensitivity and specificity for detecting significant PCa as high b-value aDWI without increased scan times and image degradation artifacts.
Cho, Eun-Suk; Kim, Joo Hee; Kim, Sungjun; Yu, Jeong-Sik; Chung, Jae-Joon; Yoon, Choon-Sik; Lee, Hyeon-Kyeong; Lee, Kyung Hee
2012-01-01
To prospectively investigate the feasibility of an 80-kilovolt (peak) (kVp) protocol in computed tomographic venography for varicose veins of the lower extremities by comparison with conventional 120-kVp protocol. Attenuation values and signal-to-noise ratio of iodine contrast medium (CM) were determined in a water phantom for 2 tube voltages (80 kVp and 120 kVp). Among 100 patients, 50 patients were scanned with 120 kVp and 150 effective milliampere second (mAs(eff)), and the other 50 patients were scanned with 80 kVp and 390 mAs(eff) after the administration of 1.7-mL/kg CM (370 mg of iodine per milliliter). The 2 groups were compared for venous attenuation, contrast-to-noise ratio, and subjective degree of venous enhancement, image noise, and overall diagnostic image quality. In the phantom, the attenuation value and signal-to-noise ratio value for iodine CM at 80 kVp were 63.8% and 33.0% higher, respectively, than those obtained at 120 kVp. The mean attenuation of the measured veins of the lower extremities was 148.3 Hounsfield units (HU) for the 80-kVp protocol and 94.8 HU for the 120-kVp protocol. Contrast-to-noise ratio was also significantly higher with the 80-kVp protocol. The overall diagnostic image quality of the 3-dimensional volume-rendered images was good with both protocols. The subjective score for venous enhancement was higher at the 80-kVp protocol. The mean volume computed tomography dose index of the 80-kVp (5.6 mGy) protocol was 23.3% lower than that of the 120-kVp (7.3 mGy) protocol. The use of the 80-kVp protocol improved overall venous attenuation, especially in perforating vein, and provided similarly high diagnostic image quality with a lower radiation dose when compared to the conventional 120-kVp protocol.
Murayama, Kazuhiro; Nishiyama, Yuya; Hirose, Yuichi; Abe, Masato; Ohyu, Shigeharu; Ninomiya, Ayako; Fukuba, Takashi; Katada, Kazuhiro; Toyama, Hiroshi
2018-01-10
We evaluated the diagnostic performance of histogram analysis of data from a combination of dynamic susceptibility contrast (DSC)-MRI and dynamic contrast-enhanced (DCE)-MRI for quantitative differentiation between central nervous system lymphoma (CNSL) and high-grade glioma (HGG), with the aim of identifying useful perfusion parameters as objective radiological markers for differentiating between them. Eight lesions with CNSLs and 15 with HGGs who underwent MRI examination, including DCE and DSC-MRI, were enrolled in our retrospective study. DSC-MRI provides a corrected cerebral blood volume (cCBV), and DCE-MRI provides a volume transfer coefficient (K trans ) for transfer from plasma to the extravascular extracellular space. K trans and cCBV were measured from a round region-of-interest in the slice of maximum size on the contrast-enhanced lesion. The differences in t values between CNSL and HGG for determining the most appropriate percentile of K trans and cCBV were investigated. The differences in K trans , cCBV, and K trans /cCBV between CNSL and HGG were investigated using histogram analysis. Receiver operating characteristic (ROC) analysis of K trans , cCBV, and K trans /cCBV ratio was performed. The 30 th percentile (C30) in K trans and 80 th percentile (C80) in cCBV were the most appropriate percentiles for distinguishing between CNSL and HGG from the differences in t values. CNSL showed significantly lower C80 cCBV, significantly higher C30 K trans , and significantly higher C30 K trans /C80 cCBV than those of HGG. In ROC analysis, C30 K trans /C80 cCBV had the best discriminative value for differentiating between CNSL and HGG as compared to C30 K trans or C80 cCBV. The combination of K trans by DCE-MRI and cCBV by DSC-MRI was found to reveal the characteristics of vascularity and permeability of a lesion more precisely than either K trans or cCBV alone. Histogram analysis of these vascular microenvironments enabled quantitative differentiation between CNSL and HGG.
Normal spinal bone marrow in adults: dynamic gadolinium-enhanced MR imaging.
Montazel, Jean-Luc; Divine, Marine; Lepage, Eric; Kobeiter, Hicham; Breil, Stephane; Rahmouni, Alain
2003-12-01
To determine the patterns of dynamic enhancement of normal spinal bone marrow in adults at gadolinium-enhanced magnetic resonance (MR) imaging and the changes that occur with aging. Dynamic contrast material-enhanced MR imaging of the thoracolumbar spine was performed in 71 patients. The maximum percentage of enhancement (Emax), enhancement slope, and enhancement washout were determined from bone marrow enhancement time curves (ETCs). The bone marrow signal intensity on T1-weighted spin-echo MR images was qualitatively classified into three grade categories. Quantitative ETC values were correlated with patient age and bone marrow fat content grade. Statistical analysis included mean t test comparison, analysis of variance, and regression analysis of the correlations between age and quantitative MR parameters. Emax, slope, and washout varied widely among the patients. Emax values were obtained within 1 minute after contrast material injection and ranged from 0% to 430%. Emax values were significantly higher in patients younger than 40 years than in those aged 40 years or older (P <.001). These values decreased with increasing age in a logarithmic relationship (r = 0.71). Emax values decreased as fat content increased, but some overlap among the fat content grades was noted. Analysis of variance revealed that Emax was significantly related to age (younger than 40 years vs 40 years or older) (P <.001) and fat content grade (P <.001) but not significantly related to sex. Dynamic contrast-enhanced MR imaging patterns of normal spinal bone marrow are dependent mainly on patient age and fat content.
A reevaluation of spectral ratios for lunar mare TiO2 mapping
NASA Technical Reports Server (NTRS)
Johnson, Jeffrey R.; Larson, Stephen M.; Singer, Robert B.
1991-01-01
The empirical relation established by Charette et al. (1974) between the 400/560-nm spectral ratio of mature mare soils and weight percent TiO2 has been used extensively to map titanium content in the lunar maria. Relative reflectance spectra of mare regions show that a reference wavelength further into the near-IR, e.g., above 700 nm, could be used in place of the 560-nm band to provide greater contrast (a greater range of ratio values) and hence a more sensitive indicator of titanium content. An analysis of 400/730-nm ratio values derived from both laboratory and telescopic relative reflectance spectra suggests that this ratio provides greater sensitivity to TiO2 content than the 400/560-nm ratio. The increased range of ratio values is manifested in higher contrast 400/730-nm ratio images compared to 400/560-nm ratio images. This potential improvement in sensivity encourages a reevaluation of the original Charette et al. (1974) relation using the 400/730-nm ratio.
Wallace, N; Dicker, S; Lewin, P; Wrenn, S P
2014-12-01
This study aims to bridge the gap between transport mechanisms of an improved ultrasound contrast agent (UCA) and its resulting behavior in a clinical imaging study. Phospholipid-shelled microbubbles nested within the aqueous core of a polymer microcapsule are examined for their use and feasibility as an improved UCA. The nested formulation provides contrast comparable to traditional formulations, specifically an SF6 microbubble coated by a DSPC PEG-3000 monolayer, with the advantage that contrast persists at least nine times longer in a mock clinical, in vitro setting. The effectiveness of the sample was measured using a contrast ratio in units of decibels (dB) which compares the brightness of the nested microbubbles to a reference value of a phantom tissue mimic. During a 40min imaging study, six nesting formulations with average outer capsule diameters of 1.95, 2.53, 5.55, 9.95, 14.95, and 20.51μm reached final contrast ratio values of 0.25, 2.35, 3.68, 4.51, 5.93, and 8.00dB, respectively. The starting contrast ratio in each case was approximately 8dB and accounts for the brightness attributed to the nesting shell. As compared with empty microcapsules (no microbubbles nested within), enhancement of the initial contrast ratio increased systematically with decreasing microcapsule size. The time required to reach a steady state in the temporal contrast ratio profile also varied with microcapsule diameter and was found to be 420s for each of the four smallest shell diameters and 210s and 150s, respectively, for the largest two shell diameters. All nested formulations were longer-lived and gave higher final contrast ratios than a control sample comprising un-nested, but otherwise equivalent, microbubbles. Specifically, the contrast ratio of the un-nested microbubbles decreased to a negative value after 4min of continuous ultrasound exposure with complete disappearance of the microbubbles after 15min whereas all nested formulations maintained positive contrast ratio values for the duration of the 40min trial. The results are consistent with two distinct stages of gas transport: in the first stage, passive diffusion occurs under ambient conditions across the microbubble monolayer within the first few minutes after formulation until the aqueous interior of the microcapsule is saturated with gas; in the second stage ultrasound drives additional gas dissolution even further due to pressure modulation. It is important to understand the chemistry and transport mechanisms of this contrast agent under the influence of ultrasound to attain better perspicacity for enhanced applications in imaging. Results from this study will facilitate future preclinical studies and clinical applications of nested microbubbles for therapeutic and diagnostic imaging. Copyright © 2014 Elsevier B.V. All rights reserved.
Cai, Wenli; Zhang, Da; Lee, June-Goo; Shirai, Yu; Kim, Se Hyung; Yoshida, Hiroyuki
2013-01-01
The purpose of our study was to measure the dual-energy index (DEI) value of colonic luminal air in both phantom and clinical fecal-tagging dual-energy computed tomography (CT) colonography (DE-CTC) images and to demonstrate its impact on dual-energy electronic cleansing. For the phantom study, a custom-ordered colon phantom was scanned by a dual-energy CT scanner (SOMATON Definition Flash; Siemens Healthcare, Forchheim, Germany) at two photon energies: 80 and 140 kVp. Before imaging, the phantom was filled with a 300-mL mixture of simulated fecal materials tagged by a nonionic iodinated contrast agent at three contrast concentrations: 20, 40, and 60 mg/mL. Ten regions-of-interest (ROIs) were randomly placed in each of the colonic luminal air, abdominal fat, bony structure, and tagged material in each scan. For the clinical study, 22 DE-CTC (80 and 140 kVp) patient cases were collected, who underwent a low-fiber, low-residue diet bowel preparation and orally administered iodine-based fecal tagging. Twenty ROIs were randomly placed in each of the colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material in each scan. For each ROI, the mean CT values in both 80- and 140-kVp images were measured, and then its DEI was calculated. In the phantom study, the mean DEI values of luminal air were 0.270, 0.298, 0.386, and 0.402 for the four groups of tagging conditions: no tagged material and tagged with three groups of contrast concentrations at 20, 40, and 60 mg/mL. In the clinical study, the mean DEI values were 0.341, -0.012, -0.002, and 0.188 for colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material, respectively. In our study, we observed that the DEI values of colonic luminal air in DE-CTC images (>0.10) were substantially higher than the theoretical value of 0.0063. In addition, the observed DEI values of colonic luminal air were significantly higher than those of soft tissue. These findings have an important impact on electronic cleansing: it may provide an effective means of differentiating colonic soft-tissue structures from the air-tagging mixture caused by the partial volume effect and thus of minimizing the cleansing artifacts.
Gd-Si Oxide Nanoparticles as Contrast Agents in Magnetic Resonance Imaging
Cabrera-García, Alejandro; Vidal-Moya, Alejandro; Bernabeu, Ángela; Pacheco-Torres, Jesús; Checa-Chavarria, Elisa; Fernández, Eduardo; Botella, Pablo
2016-01-01
We describe the synthesis, characterization and application as contrast agents in magnetic resonance imaging of a novel type of magnetic nanoparticle based on Gd-Si oxide, which presents high Gd3+ atom density. For this purpose, we have used a Prussian Blue analogue as the sacrificial template by reacting with soluble silicate, obtaining particles with nanorod morphology and of small size (75 nm). These nanoparticles present good biocompatibility and higher longitudinal and transversal relaxivity values than commercial Gd3+ solutions, which significantly improves the sensitivity of in vivo magnetic resonance images. PMID:28335240
Practical and Theoretical Knowledge in Contrast: Teacher Educators' Discursive Positions
ERIC Educational Resources Information Center
Zimmerman Nilsson, Marie-Helene
2017-01-01
Higher education in general and teacher education in particular have been subjected to significant changes. As there are few studies examining how actors rhetorically position themselves within this context, the ambition of the paper is to study conversations between teacher educators related to norms and values in education. The aim of the paper…
Schellhaas, Barbara; Görtz, Ruediger S; Pfeifer, Lukas; Kielisch, Christian; Neurath, Markus F; Strobel, Deike
2017-09-01
A comparison is made of two contrast-enhanced ultrasound (CEUS) algorithms for the diagnosis of hepatocellular carcinoma (HCC) in high-risk patients: Erlanger Synopsis of Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at Risk (ESCULAP) and American College of Radiology Contrast-Enhanced Ultrasound-Liver Imaging Reporting and Data System (ACR-CEUS-LI-RADSv.2016). Focal liver lesions in 100 high-risk patients were assessed using both CEUS algorithms (ESCULAP and CEUS-LI-RADSv.2016) for a direct comparison. Lesions were categorized according to size and contrast enhancement in the arterial, portal venous and late phases.For the definite diagnosis of HCC, categories ESCULAP-4, ESCULAP-Tr and ESCULAP-V and CEUS-LI-RADS-LR-5, LR-Tr and LR-5-V were compared. In addition, CEUS-LI-RADS-category LR-M (definitely/probably malignant, but not specific for HCC) and ESCULAP-category C [intrahepatic cholangiocellular carcinoma (ICC)] were compared.Histology, CE-computed tomography and CE-MRI served as reference standards. The reference standard among 100 lesions included 87 HCCs, six ICCs and seven non-HCC-non-ICC-lesions. For the diagnosis of HCC, the diagnostic accuracy of CEUS was significantly higher with ESCULAP versus CEUS-LI-RADS (94.3%/72.4%; p<0.01). Sensitivity, specificity and positive predictive value (PPV) and negative predictive value for ESCULAP/CEUS-LI-RADS were 94.3%/72.4%; 61.5%/69.2%; 94.3%/94%; and 61.5%/27.3%, respectively.The diagnostic accuracy for ICC (LR-M/ESCULAP-C) was identical with both algorithms (50%), with higher PPV for ESCULAP-C versus LR-M (75 vs. 50%). CEUS-based algorithms contribute toward standardized assessment and reporting of HCC-suspect lesions in high-risk patients. ESCULAP shows significantly higher diagnostic accuracy, sensitivity and negative predictive value with no loss of specificity compared with CEUS-LI-RADS. Both algorithms have an excellent PPV. Arterial hyperenhancement is the key feature for the diagnosis of HCC with CEUS. Washout should not be a necessary prerequisite for the diagnosis of definite HCC. CEUS-LI-RADS in its current version is inferior to ESCULAP for the noninvasive diagnosis of HCC. There are two ways to improve CEUS-LI-RADS: firstly, combination of the categories LR-4 and LR-5 for the diagnosis of definite HCC, and secondly, use of subtotal infiltration of a liver lobe as an additional feature.
Algül, Ali; Balci, Pinar; Seçil, Mustafa; Canda, Tülay
2003-06-01
To compare ability of detection of vascular structures by utilizing ultrasonographic contrast agent (Levovist) prior to and following power Doppler ultrasound (PDUS) and colour Doppler ultrasound (CDUS) and to determine useful parameters in the differentiation of malignant and benign breast masses by means of verified data. Vascularisation characteristics of 38 breast masses (22 malignant, 16 benign) which were confirmed by mammography and B-mode sonography were evaluated by both CDUS and PDUS following and prior to intravenous contrast application. In addition, Vmax and RI values of vascular structures were calculated by Doppler spectral evaluation. Malignant lesions showed more vascularity than benign lesions both with and without contrast enhancement. With both methods, by utilizing contrast agent, central, penetrating and tortuous vascular structures became more significant in malignant lesions when compared with benign lesions. PDUS was able to detect vascular structures better than CDUS; however, the difference was not statistically significant. Presence of peripheral vascularity was not useful in differentiating malignant from benign lesions. Vmax and RI values were higher in malignant lesions and the difference was statistically significant. In both methods, Vmax > 15 cm/sec and RI > 0.80 (CDUS), and RI > 0.70 (PDUS) were accepted as malignancy parameters. Vascular patterns of breast masses as determined with PDUS and CDUS with contrast enhancement and Doppler spectral examinations enabled differentiation of malignant and benign breast lesions. Thus, it is possible to decrease the number of unnecessary surgical interventions.
Nakada, Tsutomu; Matsuzawa, Hitoshi; Fujii, Yukihiko; Takahashi, Hitoshi; Nishizawa, Masatoyo; Kwee, Ingrid L
2006-07-01
Clinical magnetic resonance imaging (MRI) has recently entered the "high-field" era, and systems equipped with 3.0-4.0T superconductive magnets are becoming the gold standard for diagnostic imaging. While higher signal-to-noise ratio (S/N) is a definite advantage of higher field systems, higher susceptibility effect remains to be a significant trade-off. To take advantage of a higher field system in performing routine clinical images of higher anatomical resolution, we implemented a vector contrast image technique to 3.0T imaging, three-dimensional anisotropy contrast (3DAC), with a PROPELLER (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) sequence, a method capable of effectively eliminating undesired artifacts on rapid diffusion imaging sequences. One hundred subjects (20 normal volunteers and 80 volunteers with various central nervous system diseases) participated in the study. Anisotropic diffusion-weighted PROPELLER images were obtained on a General Electric (Waukesha, WI, USA) Signa 3.0T for each axis, with b-value of 1100 sec/mm(2). Subsequently, 3DAC images were constructed using in-house software written on MATLAB (MathWorks, Natick, MA, USA). The vector contrast allows for providing exquisite anatomical detail illustrated by clear identification of all major tracts through the entire brain. 3DAC images provide better anatomical resolution for brainstem glioma than higher-resolution T2 reversed images. Degenerative processes of disease-specific tracts were clearly identified as illustrated in cases of multiple system atrophy and Joseph-Machado disease. Anatomical images of significantly higher resolution than the best current standard, T2 reversed images, were successfully obtained. As a technique readily applicable under routine clinical setting, 3DAC PROPELLER on a 3.0T system will be a powerful addition to diagnostic imaging.
GAFFE: a gaze-attentive fixation finding engine.
Rajashekar, U; van der Linde, I; Bovik, A C; Cormack, L K
2008-04-01
The ability to automatically detect visually interesting regions in images has many practical applications, especially in the design of active machine vision and automatic visual surveillance systems. Analysis of the statistics of image features at observers' gaze can provide insights into the mechanisms of fixation selection in humans. Using a foveated analysis framework, we studied the statistics of four low-level local image features: luminance, contrast, and bandpass outputs of both luminance and contrast, and discovered that image patches around human fixations had, on average, higher values of each of these features than image patches selected at random. Contrast-bandpass showed the greatest difference between human and random fixations, followed by luminance-bandpass, RMS contrast, and luminance. Using these measurements, we present a new algorithm that selects image regions as likely candidates for fixation. These regions are shown to correlate well with fixations recorded from human observers.
Kawashima, Hiroko; Miyati, Tosiaki; Ohno, Naoki; Ohno, Masako; Inokuchi, Masafumi; Ikeda, Hiroko; Gabata, Toshifumi
2017-12-01
The study aimed to investigate whether intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) can differentiate luminal-B from luminal-A breast cancer MATERIALS AND METHODS: Biexponential analyses of IVIM and DCE MRI were performed using a 3.0-T MRI scanner, involving 134 patients with 137 pathologically confirmed luminal-type invasive breast cancers. Luminal-type breast cancer was categorized as luminal-B breast cancer (LBBC, Ki-67 ≧ 14%) or luminal-A breast cancer (LABC, Ki-67 < 14%). Quantitative parameters from IVIM (pure diffusion coefficient [D], perfusion-related diffusion coefficient [D*], and fraction [f]) and DCE MRI (initial percentage of enhancement and signal enhancement ratio [SER]) were calculated. The apparent diffusion coefficient (ADC) was also calculated using monoexponential fitting. We correlated these data with the Ki-67 status. The D and ADC values of LBBC were significantly lower than those of LABC (P = 0.028, P = 0.037). The SER of LBBC was significantly higher than that of LABC (P = 0.004). A univariate analysis showed that a significantly lower D (<0.847 x 10 -3 mm 2 /s), lower ADC (<0.960 × 10 -3 mm 2 /s), and higher SER (>1.071) values were associated with LBBC (all P values <0.01), compared to LABC. In a multivariate analysis, a higher SER (>1.071; odds ratio: 3.0099, 95% confidence interval: 1.4246-6.3593; P = 0.003) value and a lower D (<0.847 × 10 -3 mm 2 /s; odds ratio: 2.6878, 95% confidence interval: 1.0445-6.9162; P = 0.040) value were significantly associated with LBBC, compared to LABC. The SER derived from DCE MRI and the D derived from IVIM are associated independently with the Ki-67 status in patients with luminal-type breast cancer. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Masculine Norms, Avoidant Coping, Asian Values and Depression among Asian American Men.
Iwamoto, Derek Kenji; Liao, Liang; Liu, William Ming
2010-01-01
Contrary to the "model minority" myth, growing research indicates that the rates of mental health problems among Asian Americans may be higher than initially assumed. This study seeks to add to the scant knowledge regarding the mental health of Asian American men by examining the role of masculine norms, coping and cultural values in predicting depression among this population (N=149). Results reveal that Asian American men who used avoidant coping strategies and endorsed the masculine norm Dominance reported higher levels of depressive symptoms. In contrast, endorsing Winning masculine norms was associated to lower levels of depressive symptoms. Findings suggest that adherence to masculine norms and avoidant coping strategies play a salient role in the mental health of Asian American men.
Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A
2013-03-01
To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.
Schubert, Tilman; Takes, Martin; Aschwanden, Markus; Klarhoefer, Markus; Haas, Tanja; Jacob, Augustinus L; Liu, David; Gutzeit, Andreas; Kos, Sebastian
2016-08-01
This study was conducted in order to compare a high resolution, non-contrast-enhanced MRA (NATIVE SPACE, NE-MRA) of the pedal vasculature with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). The prospective study consists of 20 PAOD patients. All patients underwent percutaneous transluminal angioplasty or stenting and received MR angiographies the following day. With CE-MRA, 75.7 % of vessel segments showed good, 16.4 % suboptimal and 7.9 % not usable image quality. With NE-MRA, 64.6 % showed good, 18.6 % suboptimal and 16.8 % not usable image quality. CE-MRA showed a sensitivity and negative predictive value of 90 %/95 % regarding significant stenosis (greater than 50 %), and specificity and positive predictive value were 88 %/77 %. Accordingly, sensitivity and negative predictive value for the NE-MRA were 96 %/97 % and specificity and positive predictive value were 80 %/69 % for stenoses greater than 50 %. The applied NE-MRA technique achieves high diagnostic accuracy even in very small distal arteries of the foot. However, the rate of non-diagnostic vessel segments is considerably higher for NE-MRA than for CE-MRA. NE-MRA is a valuable alternative to CE-MRA in selected patients. • Comparison of non-enhanced MRA with contrast-enhanced MRA and DSA as gold standard. • High resolution MRA at 3 T for the depiction of small pedal vessels. • Evaluation of high resolution non-enhanced MRA in PAOD patients.
Exploring silver as a contrast agent for contrast-enhanced dual-energy X-ray breast imaging
Tsourkas, A; Maidment, A D A
2014-01-01
Objective: Through prior monoenergetic modelling, we have identified silver as a potential alternative to iodine in dual-energy (DE) X-ray breast imaging. The purpose of this study was to compare the performance of silver and iodine contrast agents in a commercially available DE imaging system through a quantitative analysis of signal difference-to-noise ratio (SDNR). Methods: A polyenergetic simulation algorithm was developed to model the signal intensity and noise. The model identified the influence of various technique parameters on SDNR. The model was also used to identify the optimal imaging techniques for silver and iodine, so that the two contrast materials could be objectively compared. Results: The major influences on the SDNR were the low-energy dose fraction and breast thickness. An increase in the value of either of these parameters resulted in a decrease in SDNR. The SDNR for silver was on average 43% higher than that for iodine when imaged at their respective optimal conditions, and 40% higher when both were imaged at the optimal conditions for iodine. Conclusion: A silver contrast agent should provide benefit over iodine, even when translated to the clinic without modification of imaging system or protocol. If the system were slightly modified to reflect the lower k-edge of silver, the difference in SDNR between the two materials would be increased. Advances in knowledge: These data are the first to demonstrate the suitability of silver as a contrast material in a clinical contrast-enhanced DE image acquisition system. PMID:24998157
Visual Contrast Enhancement Algorithm Based on Histogram Equalization
Ting, Chih-Chung; Wu, Bing-Fei; Chung, Meng-Liang; Chiu, Chung-Cheng; Wu, Ya-Ching
2015-01-01
Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE) because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA) based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods. PMID:26184219
2014-01-01
wild-type spores but ~15-fold higher deltaTrelease values; v ) germination kinetics of wild-type spores given a ? 30 sec 140 MPa HP pulse followed by...15-fold longer than those for wild-type spores, but the two types of spores exhibited similar average Tlag values; and ( v ) the germination of wild-type...committed spores, as it does for nutrient-committed spores (14)? ( v ) Can these HP-com- mitted spores be isolated under conditions that do not allow
NASA Astrophysics Data System (ADS)
Singam, Shashi K. R.; Motylewski, Jaroslaw; Monaco, Antonina; Gjorgievska, Elena; Bourgeois, Emilie; Nesládek, Milos; Giugliano, Michele; Goovaerts, Etienne
2016-12-01
Diamond nanoparticles with negatively charged nitrogen-vacancy (NV) centers are highly efficient nonblinking emitters that exhibit spin-dependent intensity. An attractive application of these emitters is background-free fluorescence microscopy exploiting the fluorescence quenching induced either by resonant microwaves (RMWs) or by an applied static magnetic field (SMF). Here, we compare RMW- and SMF-induced contrast measurements over a wide range of optical excitation rates for fluorescent nanodiamonds (FNDs) and for NV centers shallowly buried under the (100)-oriented surface of a diamond single crystal (SC). Contrast levels are found to be systematically lower in the FNDs than in the SC. At low excitation rates, the RMW contrast initially rises to a maximum (up to 7% in FNDs and 13% in the SC) but then decreases steadily at higher intensities. Conversely, the SMF contrast increases from approximately 12% at low excitation rates to high values of 20% and 38% for the FNDs and SC, respectively. These observations are well described in a rate-equations model for the charged NV defect using parameters in good agreement with the literature. The SMF approach yields higher induced contrast in image collection under commonly applied optical excitation. Unlike the RMW method, there is no thermal load exerted on the aqueous media in biological samples in the SMF approach. We demonstrate imaging by SMF-induced contrast in neuronal cultures incorporating FNDs (i) in a setup for patch-clamp experiments in parallel with differential-interference-contrast microscopy, (ii) after a commonly used staining procedure as an illustration of the high selectivity against background fluorescence, and (iii) in a confocal fluorescence microscope in combination with bright-field microscopy.
ERIC Educational Resources Information Center
Briggs, Senga
2006-01-01
This article explores the factors influencing student choice at six contrasting universities in Scotland to establish if there is value in developing a model for predicting institutional choice for Scottish undergraduate entry. It is based on a survey of 651 students in two undergraduate disciplines, accountancy and engineering, across the six…
Photometric Properties of Network and faculae derived by HMI data compensated for scattered-light
NASA Astrophysics Data System (ADS)
Criscuoli, Serena; Norton, Aimee Ann; Whitney, Taylor
2017-08-01
We report on the photometric properties of faculae and network as observed in full-disk,scattered-light corrected images from the Helioseismic Magnetic Imager (HMI). We usea Lucy-Richardson deconvolution routine that corrects a full-disk intensity image in lessthan one second. Faculae are distinguished from network through proximity to activeregions in addition to continuum intensity and magnetogram thresholds. This is the firstreport that full-disk image data, including center-to-limb variations, reproduce the photometric properties of faculae and network observed previously only in sub-arcsecond resolution, small field-of-view studies, i.e. that network exhibit in general higher photometric contrasts. More specifically, for magnetic flux values larger than approximately 300 G, the network is always brighter than faculae and the contrast differences increases toward the limb, where the network contrast is about twice the facular one. For lower magnetic flux values, pixels in network regions appear always darker than facular ones. Contrary to reports from previous full-disk observations, we also found that network exhibits a higher center-to-limb variation. Our results are in agreement with reports from simulations that indicate magnetic flux alone is a poor proxy of the photometric properties of magnetic features. We estimate that the facular and network contribution to irradiance variability of the current Cycle 24 is overestimated by at least 11% due to the photometric properties of network and faculae not being recognized as distinctly different.
Cano, F Javier; López, Rosana; Warren, Charles R
2014-11-01
Water stress (WS) slows growth and photosynthesis (A(n)), but most knowledge comes from short-time studies that do not account for longer term acclimation processes that are especially relevant in tree species. Using two Eucalyptus species that contrast in drought tolerance, we induced moderate and severe water deficits by withholding water until stomatal conductance (g(sw)) decreased to two pre-defined values for 24 d, WS was maintained at the target g(sw) for 29 d and then plants were re-watered. Additionally, we developed new equations to simulate the effect on mesophyll conductance (g(m)) of accounting for the resistance to refixation of CO(2). The diffusive limitations to CO(2), dominated by the stomata, were the most important constraints to A(n). Full recovery of A(n) was reached after re-watering, characterized by quick recovery of gm and even higher biochemical capacity, in contrast to the slower recovery of g(sw). The acclimation to long-term WS led to decreased mesophyll and biochemical limitations, in contrast to studies in which stress was imposed more rapidly. Finally, we provide evidence that higher gm under WS contributes to higher intrinsic water-use efficiency (iWUE) and reduces the leaf oxidative stress, highlighting the importance of gm as a target for breeding/genetic engineering. © 2014 John Wiley & Sons Ltd.
Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh
2016-01-01
Background Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). Patients and Methods With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. Results A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84–12.82). Conclusion DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers. PMID:27611215
Schoeninger, Margaret J; Most, Corinna A; Moore, Jim J; Somerville, Andrew D
2016-10-01
Diet influences the stable isotope ratios of carbon and nitrogen (δ(13) C and δ(15) N values) in animal tissue; but here we explore the influences of particular aspects of the local environment on those values in chimpanzees (Pan troglodytes). In this article we present new δ(13) C and δ(15) N values in Gombe chimpanzees using hairs collected from night nests in 1989. Then, we explore the influence of environmental factors by comparing our Gombe data to those from eight additional Pan study sites with previously published stable isotope data. We compare chimpanzee δ(13) Chair and δ(15) Nhar values to specific characteristics of local site ecology (biome and ecoregion) and to local Mean Annual Precipitation (MAP) to test hypotheses based on known effects of these variables on the δ(13) C and δ(15) N values in plant tissues. The comparison shows that hair from chimpanzees living in savanna sites with lower MAP have higher δ(13) Chair values than do chimpanzees living in woodland and forested sites with higher MAP. These results demonstrate the potential of using δ(13) C values in primate tissue to indicate aspects of their local ecology in cases where the ecology is uncertain, such as samples collected early in the last century and in fossil hominins. In contrast to expectations, however, chimpanzee δ(15) Nhair values from some savanna sites with lower MAP are lower, not higher, than those living in more forested areas with higher MAP. It is likely that diet selectivity by chimpanzees affects δ(15) Nhair values to a greater extent than does the influence of precipitation on plants. Am. J. Primatol. 78:1055-1069, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Temporal dynamics of contrast gain in single cells of the cat striate cortex.
Bonds, A B
1991-03-01
The response amplitude of cat striate cortical cells is usually reduced after exposure to high-contrast stimuli. The temporal characteristics and contrast sensitivity of this phenomenon were explored by stimulating cortical cells with drifting gratings in which contrast sequentially incremented and decremented in stepwise fashion over time. All responses showed a clear hysteresis, in which contrast gain dropped on average 0.36 log unit and then returned to baseline values within 60 s. Noticeable gain adjustments were seen in as little as 3 s and with peak contrasts as low as 3%. Contrast adaptation was absent in responses from LGN cells. Adaptation was found to depend on temporal frequency of stimulation, with greater and more rapid adaptation at higher temporal frequencies. Two different tests showed that the mechanism controlling response reduction was influenced primarily by stimulus contrast rather than response amplitude. These results support the existence of a rapid and sensitive cortically based system that normalizes the output of cortical cells as a function of local mean contrast. Control of the adaptation appears to arise at least in part across a population of cells, which is consistent with the idea that the gain control serves to limit the information converging from many cells onto subsequent processing areas.
Huang, Jinbai; Luo, Jing; Peng, Jie; Yang, Tao; Zheng, Huanghua; Mao, Chunping
2017-11-01
Background Diffusion-weighted imaging (DWI) was introduced into clinical use some years ago. However, its use in the diagnosis of cerebral schistosomiasis has not been reported. Purpose To investigate the ability of the apparent diffusion coefficient (ADC) value of DWI in the diagnosis of cerebral schistosomiasis, and to differentiate it from brain high-grade gliomas and metastasis. Material and Methods Conventional brain MRI with pre-contrast, post-contrast, and DWI was performed on 50 cases of cerebral schistosomiasis, high-grade glioma, and brain metastasis. The ADC values of the three lesions, the proximal and the distal perifocal edema were measured. In order to remove the individual difference effect of ADC values, relative ADC (rADC) values were calculated through dividing the ADC value of the lesion area by that of the contralateral normal white matter. rADC values were used to evaluate the differences among cerebral schistosomiasis, brain high-grade gliomas, and metastasis. Results rADC of cerebral schistosomiasis was significantly lower than rADC of brain metastasis ( P < 0.05), without any significant differences when compared with high-grade gliomas. rADC of proximal perifocal edema in cerebral schistosomiasis was significantly higher than in high-grade gliomas ( P < 0.010), but not different compared with brain metastasis. Conclusion DWI examination with ADC values of lesions and proximal perifocal edema might be helpful in the exact diagnosis of cerebral schistosomiasis.
Dynamical structure of pure Lovelock gravity
NASA Astrophysics Data System (ADS)
Dadhich, Naresh; Durka, Remigiusz; Merino, Nelson; Miskovic, Olivera
2016-03-01
We study the dynamical structure of pure Lovelock gravity in spacetime dimensions higher than four using the Hamiltonian formalism. The action consists of a cosmological constant and a single higher-order polynomial in the Riemann tensor. Similarly to the Einstein-Hilbert action, it possesses a unique constant curvature vacuum and charged black hole solutions. We analyze physical degrees of freedom and local symmetries in this theory. In contrast to the Einstein-Hilbert case, the number of degrees of freedom depends on the background and can vary from zero to the maximal value carried by the Lovelock theory.
Jiang, Jingxuan; Xiao, Zebin; Tang, Zuohua; Zhong, Yufeng; Qiang, Jinwei
2018-01-01
To explore the value of dynamic contrast-enhanced MRI (DCE-MRI) and intravoxel incoherent motion (IVIM) for distinguishing between benign and malignant sinonasal lesions and investigate the correlations between the two methods. Patients with sinonasal lesions (42 benign and 31 malignant) who underwent DCE-MRI and IVIM before confirmation by histopathology were enrolled in this prospective study. Parameters derived from DCE-MRI and IVIM were measured, the optimal cut-off values for differential diagnosis were determined, and the correlations between the two methods were evaluated. Statistical analyses were performed using the Wilcoxon rank sum test, receiver operating characteristic (ROC) curve analysis, and Spearman's rank correlation. Significantly higher K trans and K ep values but lower D and f values were found in malignant lesions than in benign lesions (all p<0.001). There were no significant differences in the V e and D* values between the two groups. The area under the curve (AUC) of K trans was significantly higher than those of other parameters. There was no significant difference between the AUCs of DCE-MRI and IVIM with parameters combined (p=0.86). Significant inverse but weak correlations were found between D and K trans (r=-0.46, p<0.001), f and K trans (r=-0.41, p<0.001), D and K ep (r=-0.37, p=0.008), and f and K ep (r=-0.33, p=0.004). DCE-MRI and IVIM can effectively differentiate between benign and malignant sinonasal lesions. IVIM findings correlate with DCE-MRI results and may represent an alternative to DCE-MRI. Copyright © 2017 Elsevier B.V. All rights reserved.
Fan, Wei Xiong; Chen, Xiao Feng; Cheng, Feng Yan; Cheng, Ya Bao; Xu, Tai; Zhu, Wen Biao; Zhu, Xiao Lei; Li, Gui Jin; Li, Shuai
2018-01-01
Abstract We explored the utility of time-resolved angiography with interleaved stochastic trajectories dynamic contrast-enhanced magnetic resonance imaging (TWIST DCE-MRI), readout segmentation of long variable echo-trains diffusion-weighted magnetic resonance imaging- diffusion-weighted magnetic resonance imaging (RESOLVE-DWI), and echo-planar imaging- diffusion-weighted magnetic resonance imaging (EPI-DWI) for distinguishing between malignant and benign breast lesions. This retrospective analysis included female patients with breast lesions seen at a single center in China between January 2016 and April 2016. Patients were allocated to a benign or malignant group based on pathologic diagnosis. All patients received routine MRI, RESOLVE-DWI, EPI-DWI, and TWIST DCE-T1WI. Variables measured included quantitative parameters (Ktrans, Kep, and Ve), semiquantitative parameters (rate of contrast enhancement for contrast agent inflow [W-in], rate of contrast decay for contrast agent outflow [W-out], and time-to-peak enhancement after contrast agent injection [TTP]) and apparent diffusion coefficient (ADC) values for RESOLVE-DWI (ADCr) and EPI-DWI (ADCe). Receiver-operating characteristic (ROC) curve analysis was used to evaluate the diagnostic utility of each parameter for differentiating malignant from benign breast lesions. A total of 87 patients were included (benign, n = 20; malignant, n = 67). Compared with the benign group, the malignant group had significantly higher Ktrans, Kep and W-in and significantly lower W-out, TTP, ADCe, and ADCr (all P < .05); Ve was not significantly different between groups. RESOLVE-DWI was superior to conventional EPI-DWI at illustrating lesion boundary and morphology, while ADCr was significantly lower than ADCe in all patients. Kep, W-out, ADCr, and ADCe showed the highest diagnostic efficiency (based on AUC value) for differentiating between benign and malignant lesions. Combining 3 parameters (Kep, W-out, and ADCr) had a higher diagnostic efficiency (AUC, 0.965) than any individual parameter and distinguished between benign and malignant lesions with high sensitivity (91.0%), specificity (95.0%), and accuracy (91.9%). An index combining Kep, W-out, and ADCr could potentially be used for the differential diagnosis of breast lesions. PMID:29369183
Fan, Wei Xiong; Chen, Xiao Feng; Cheng, Feng Yan; Cheng, Ya Bao; Xu, Tai; Zhu, Wen Biao; Zhu, Xiao Lei; Li, Gui Jin; Li, Shuai
2018-01-01
We explored the utility of time-resolved angiography with interleaved stochastic trajectories dynamic contrast-enhanced magnetic resonance imaging (TWIST DCE-MRI), readout segmentation of long variable echo-trains diffusion-weighted magnetic resonance imaging- diffusion-weighted magnetic resonance imaging (RESOLVE-DWI), and echo-planar imaging- diffusion-weighted magnetic resonance imaging (EPI-DWI) for distinguishing between malignant and benign breast lesions.This retrospective analysis included female patients with breast lesions seen at a single center in China between January 2016 and April 2016. Patients were allocated to a benign or malignant group based on pathologic diagnosis. All patients received routine MRI, RESOLVE-DWI, EPI-DWI, and TWIST DCE-T1WI. Variables measured included quantitative parameters (K, Kep, and Ve), semiquantitative parameters (rate of contrast enhancement for contrast agent inflow [W-in], rate of contrast decay for contrast agent outflow [W-out], and time-to-peak enhancement after contrast agent injection [TTP]) and apparent diffusion coefficient (ADC) values for RESOLVE-DWI (ADCr) and EPI-DWI (ADCe). Receiver-operating characteristic (ROC) curve analysis was used to evaluate the diagnostic utility of each parameter for differentiating malignant from benign breast lesions.A total of 87 patients were included (benign, n = 20; malignant, n = 67). Compared with the benign group, the malignant group had significantly higher K, Kep and W-in and significantly lower W-out, TTP, ADCe, and ADCr (all P < .05); Ve was not significantly different between groups. RESOLVE-DWI was superior to conventional EPI-DWI at illustrating lesion boundary and morphology, while ADCr was significantly lower than ADCe in all patients. Kep, W-out, ADCr, and ADCe showed the highest diagnostic efficiency (based on AUC value) for differentiating between benign and malignant lesions. Combining 3 parameters (Kep, W-out, and ADCr) had a higher diagnostic efficiency (AUC, 0.965) than any individual parameter and distinguished between benign and malignant lesions with high sensitivity (91.0%), specificity (95.0%), and accuracy (91.9%).An index combining Kep, W-out, and ADCr could potentially be used for the differential diagnosis of breast lesions.
Encouraging use of coupons to stimulate condom purchase.
Dahl, D W; Gorn, G J; Weinberg, C B
1999-01-01
OBJECTIVES: This study examined the feasibility of using high-value coupons to induce condom purchase and evaluated execution factors that can influence the effectiveness of this form of promotion. METHODS: Two levels of coupon discount value (10% off and 75% off) were used to promote condom purchase among young adults. Coupons were distributed according to a widespread strategy or a more focused in-store disbursement method. RESULTS: Redemption of coupons distributed through the widespread disbursement strategy was negligible. In contrast, coupons from the in-store distribution method, particularly the higher value coupon, resulted in a high redemption rate. CONCLUSIONS: This research provides strong evidence that discount coupons, particularly high-value ones distributed at the purchase location, can be used successfully as a condom promotional incentive. PMID:10589320
Tranquart, F; Bleuzen, A; Kissel, A
2004-06-01
To assess the value of combined conventional and contrast-material enhanced sonography for the characterization of focal liver lesions. Simultaneous imaging with grey scale and contrast enhanced US was performed in 90 patients following Levovist injection (Schering, Berlin, Germany) using the "Agent Detection Imaging" method (ADI, Siemens-Acuson, Mountain View, USA). US scanning was performed at least 4 minutes after contrast injection with review of both grayscale and contrast enhanced modes. Results for detection and characterization of lesions were compared to the selected gold standard imaging modality (CT or MRI). Final diagnoses included: 20 normal examinations, 41 patients with metastases, 6 patients with hepatocellular carcinoma, 13 patients with hemangioma, 6 patients with other benign lesions, 4 patients with cysts and 6 patients with two types of lesions. Delayed phase contrast enhanced US allowed diagnosis of all lesions except for one metastasis and all hepatocellular carcinomas. While the diagnosis of hepatoma could not be confirmed, the features suggested a malignant etiology. For 7 patients with metastases, more lesions were detected at ADI (4.9 lesions) than at conventional US (1.1 lesion). For 3 patients, CT showed more lesions than ADI US (3.3 versus 1.6 lesions). The accuracy of ADI US for differentiating between benign and malignant lesions was 98.7% compared to 49.6% for conventional US (p<0.001). The total number of lesions detected at ADI US was higher (p<0.01) than at conventional US and not significantly different from that obtained by the gold standard reference methods. Complete characterization was achieved in 92.2% of cases with ADI US compared to 59.2% with conventional US (p<0.001). Contrast-material enhanced US combined with conventional US markedly improves the diagnostic accuracy of US in terms of lesion detection and characterization.
Wang, Lin; Du, Jing; Li, Feng-Hua; Fang, Hua; Hua, Jia; Wan, Cai-Feng
2013-10-01
The purpose of this study was to evaluate the diagnostic efficacy of contrast-enhanced sonography for differentiation of breast lesions by combined qualitative and quantitative analyses in comparison to magnetic resonance imaging (MRI). Fifty-six patients with American College of Radiology Breast Imaging Reporting and Data System category 3 to 5 breast lesions on conventional sonography were evaluated by contrast-enhanced sonography and MRI. A comparative analysis of diagnostic results between contrast-enhanced sonography and MRI was conducted in light of the pathologic findings. Pathologic analysis showed 26 benign and 30 malignant lesions. The predominant enhancement patterns of the benign lesions on contrast-enhanced sonography were homogeneous, centrifugal, and isoenhancement or hypoenhancement, whereas the patterns of the malignant lesions were mainly heterogeneous, centripetal, and hyperenhancement. The detection rates for perfusion defects and peripheral radial vessels in the malignant group were much higher than those in the benign group (P < .05). As to quantitative analysis, statistically significant differences were found in peak and time-to-peak values between the groups (P < .05). With pathologic findings as the reference standard, the sensitivity, specificity, and accuracy of contrast-enhanced sonography and MRI were 90.0%, 92.3%, 91.1% and 96.7%, 88.5%, and 92.9%, respectively. The two methods had a concordant rate of 87.5% (49 of 56), and the concordance test gave a value of κ = 0.75, indicating that there was high concordance in breast lesion assessment between the two diagnostic modalities. Contrast-enhanced sonography provided typical enhancement patterns and valuable quantitative parameters, which showed good agreement with MRI in diagnostic efficacy and may potentially improve characterization of breast lesions.
Zentall, Thomas R; Singer, Rebecca A
2007-07-01
When behavior suggests that the value of a reinforcer depends inversely on the value of the events that precede or follow it, the behavior has been described as a contrast effect. Three major forms of contrast have been studied: incentive contrast, in which a downward (or upward) shift in the magnitude of reinforcement produces a relatively stronger downward (or upward) shift in the vigor of a response; anticipatory contrast, in which a forthcoming improvement in reinforcement results in a relative reduction in consummatory response; and behavioral contrast, in which a decrease in the probability of reinforcement in one component of a multiple schedule results in an increase in responding in an unchanged component of the schedule. Here we discuss a possible fourth kind of contrast that we call within-trial contrast because within a discrete trial, the relative value of an event has an inverse effect on the relative value of the reinforcer that follows. We show that greater effort, longer delay to reinforcement, or the absence of food all result in an increase in the preference for positive discriminative stimuli that follow (relative to less effort, shorter delay, or the presence of food). We further distinguish this within-trial contrast effect from the effects of delay reduction. A general model of this form of contrast is proposed in which the value of a primary or conditioned reinforcer depends on the change in value from the value of the event that precedes it.
Zentall, Thomas R; Singer, Rebecca A
2007-01-01
When behavior suggests that the value of a reinforcer depends inversely on the value of the events that precede or follow it, the behavior has been described as a contrast effect. Three major forms of contrast have been studied: incentive contrast, in which a downward (or upward) shift in the magnitude of reinforcement produces a relatively stronger downward (or upward) shift in the vigor of a response; anticipatory contrast, in which a forthcoming improvement in reinforcement results in a relative reduction in consummatory response; and behavioral contrast, in which a decrease in the probability of reinforcement in one component of a multiple schedule results in an increase in responding in an unchanged component of the schedule. Here we discuss a possible fourth kind of contrast that we call within-trial contrast because within a discrete trial, the relative value of an event has an inverse effect on the relative value of the reinforcer that follows. We show that greater effort, longer delay to reinforcement, or the absence of food all result in an increase in the preference for positive discriminative stimuli that follow (relative to less effort, shorter delay, or the presence of food). We further distinguish this within-trial contrast effect from the effects of delay reduction. A general model of this form of contrast is proposed in which the value of a primary or conditioned reinforcer depends on the change in value from the value of the event that precedes it. PMID:17725056
Gillespie-Gallery, Hanna; Konstantakopoulou, Evgenia; Harlow, Jonathan A; Barbur, John L
2013-09-09
It is challenging to separate the effects of normal aging of the retina and visual pathways independently from optical factors, decreased retinal illuminance, and early stage disease. This study determined limits to describe the effect of light level on normal, age-related changes in monocular and binocular functional contrast sensitivity. We recruited 95 participants aged 20 to 85 years. Contrast thresholds for correct orientation discrimination of the gap in a Landolt C optotype were measured using a 4-alternative, forced-choice (4AFC) procedure at screen luminances from 34 to 0.12 cd/m(2) at the fovea and parafovea (0° and ±4°). Pupil size was measured continuously. The Health of the Retina index (HRindex) was computed to capture the loss of contrast sensitivity with decreasing light level. Participants were excluded if they exhibited performance outside the normal limits of interocular differences or HRindex values, or signs of ocular disease. Parafoveal contrast thresholds showed a steeper decline and higher correlation with age at the parafovea than the fovea. Of participants with clinical signs of ocular disease, 83% had HRindex values outside the normal limits. Binocular summation of contrast signals declined with age, independent of interocular differences. The HRindex worsens more rapidly with age at the parafovea, consistent with histologic findings of rod loss and its link to age-related degenerative disease of the retina. The HRindex and interocular differences could be used to screen for and separate the earliest stages of subclinical disease from changes caused by normal aging.
Teaching High-Value Pronunciation Features: Contrastive Stress for Intermediate Learners
ERIC Educational Resources Information Center
Levis, John M.; Levis, Greta Muller
2018-01-01
Pronunciation features are not equal in how they affect listeners' ability to understand. Some are low value, while others are high value. This study explores whether contrastive stress is high value. Previous research has shown that identification of contrastive stress is learnable (Pennington & Ellis, 2000), and that explicit teaching about…
Masculine Norms, Avoidant Coping, Asian Values and Depression among Asian American Men
Iwamoto, Derek Kenji; Liao, Liang; Liu, William Ming
2010-01-01
Contrary to the “model minority” myth, growing research indicates that the rates of mental health problems among Asian Americans may be higher than initially assumed. This study seeks to add to the scant knowledge regarding the mental health of Asian American men by examining the role of masculine norms, coping and cultural values in predicting depression among this population (N=149). Results reveal that Asian American men who used avoidant coping strategies and endorsed the masculine norm Dominance reported higher levels of depressive symptoms. In contrast, endorsing Winning masculine norms was associated to lower levels of depressive symptoms. Findings suggest that adherence to masculine norms and avoidant coping strategies play a salient role in the mental health of Asian American men. PMID:20657794
NASA Astrophysics Data System (ADS)
Cao, G.; Weber, S. J.; Martin, S. O.; Sridharan, K.; Anderson, M. H.; Allen, T. R.
2013-10-01
Emissivity measurements for candidate alloys for very high temperature reactors were carried out in a custom-built experimental facility, capable of both efficient and reliable measurements of spectral emissivities of multiple samples at high temperatures. The alloys studied include 304 and 316 austenitic stainless steels, Alloy 617, and SA508 ferritic steel. The oxidation of alloys plays an important role in dictating emissivity values. The higher chromium content of 304 and 316 austenitic stainless steels, and Alloy 617 results in an oxide layer only of sub-micron thickness even at 700 °C and consequently the emissivity of these alloys remains low. In contrast, the low alloy SA508 ferritic steel which contains no chromium develops a thicker oxide layer, and consequently exhibits higher emissivity values.
Mihl, Casper; Wildberger, Joachim E; Jurencak, Tomas; Yanniello, Michael J; Nijssen, Estelle C; Kalafut, John F; Nalbantov, Georgi; Mühlenbruch, Georg; Behrendt, Florian F; Das, Marco
2013-11-01
Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR. A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined. All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds). This phantom study demonstrates that constant injection parameters (IDR, overall iodine load) lead to robust enhancement patterns, regardless of the contrast material used. Higher iodine concentration itself does not lead to higher attenuation levels. These results may stimulate a shift in paradigm toward clinical usage of contrast media with lower iodine concentrations (eg, 240 mg iodine/mL) in individual tailored contrast protocols. The use of low-iodine concentration contrast media is desirable because of the lower viscosity and the resulting lower injection pressure.
Memory Performance for Everyday Motivational and Neutral Objects Is Dissociable from Attention
Schomaker, Judith; Wittmann, Bianca C.
2017-01-01
Episodic memory is typically better for items coupled with monetary reward or punishment during encoding. It is yet unclear whether memory is also enhanced for everyday objects with appetitive or aversive values learned through a lifetime of experience, and to what extent episodic memory enhancement for motivational and neutral items is attributable to attention. In a first experiment, we investigated attention to everyday motivational objects using eye-tracking during free-viewing and subsequently tested episodic memory using a remember/know procedure. Attention was directed more to aversive stimuli, as evidenced by longer viewing durations, whereas recollection was higher for both appetitive and aversive objects. In the second experiment, we manipulated the visual contrast of neutral objects through changes of contrast to further dissociate attention and memory encoding. While objects presented with high visual contrast were looked at longer, recollection was best for objects presented in unmodified, medium contrast. Generalized logistic mixed models on recollection performance showed that attention as measured by eye movements did not enhance subsequent memory, while motivational value (Experiment 1) and visual contrast (Experiment 2) had quadratic effects in opposite directions. Our findings suggest that an enhancement of incidental memory encoding for appetitive items can occur without an increase in attention and, vice versa, that enhanced attention towards salient neutral objects is not necessarily associated with memory improvement. Together, our results provide evidence for a double dissociation of attention and memory effects under certain conditions. PMID:28694774
Idiopathic granulomatous mastitis: magnetic resonance imaging findings with diffusion MRI.
Aslan, Hulya; Pourbagher, Aysin; Colakoglu, Tamer
2016-07-01
Idiopathic granulomatous mastitis (IGM) is a rare benign breast disease with unknown etiology which can mimic breast carcinoma, both clinically and radiologically. Magnetic resonance imaging (MRI) findings of IGM have been previously described; however there is no study evaluating diffusion-weighted MRI findings of IGM. To analyze conventional, dynamic contrast-enhanced, and diffusion-weighted MRI signal characteristics of IGM by comparing it with the contralateral normal breast parenchyma. A total of 39 patients were included in the study. On dynamic contrast-enhanced MRI, the distribution and enhancement patterns of the lesions were evaluated. We also detected the frequencies of involving quadrants, retroareolar involvement, accompanying abscess, and skin edema. T2-weighted (T2W) and STIR signal intensities and both mean and minimum apparent diffusion coefficient (ADC) values were compared with the contralateral normal parenchyma. IGM showed significantly lower mean and minimum ADC values when compared with the normal parenchyma. Signal intensities on T2W and STIR sequences of the lesion were significantly higher than the normal parenchyma. On dynamic contrast-enhanced MRI, 7.7% of the patients had mass-like contrast enhancement, 92.3% of the patients had non-mass-like contrast enhancement. Abscess was positive in 33.3% of the patients. As a result, IGM showed commonly non-mass-like lesions with restricted diffusion. Although it is a benign pathology, it may show clustered ring-like enhancement like malignant lesions. © The Foundation Acta Radiologica 2015.
The role of pulvinar in the transmission of information in the visual hierarchy.
Cortes, Nelson; van Vreeswijk, Carl
2012-01-01
VISUAL RECEPTIVE FIELD (RF) ATTRIBUTES IN VISUAL CORTEX OF PRIMATES HAVE BEEN EXPLAINED MAINLY FROM CORTICAL CONNECTIONS: visual RFs progress from simple to complex through cortico-cortical pathways from lower to higher levels in the visual hierarchy. This feedforward flow of information is paired with top-down processes through the feedback pathway. Although the hierarchical organization explains the spatial properties of RFs, is unclear how a non-linear transmission of activity through the visual hierarchy can yield smooth contrast response functions in all level of the hierarchy. Depending on the gain, non-linear transfer functions create either a bimodal response to contrast, or no contrast dependence of the response in the highest level of the hierarchy. One possible mechanism to regulate this transmission of visual contrast information from low to high level involves an external component that shortcuts the flow of information through the hierarchy. A candidate for this shortcut is the Pulvinar nucleus of the thalamus. To investigate representation of stimulus contrast a hierarchical model network of ten cortical areas is examined. In each level of the network, the activity from the previous layer is integrated and then non-linearly transmitted to the next level. The arrangement of interactions creates a gradient from simple to complex RFs of increasing size as one moves from lower to higher cortical levels. The visual input is modeled as a Gaussian random input, whose width codes for the contrast. This input is applied to the first area. The output activity ratio among different contrast values is analyzed for the last level to observe sensitivity to a contrast and contrast invariant tuning. For a purely cortical system, the output of the last area can be approximately contrast invariant, but the sensitivity to contrast is poor. To account for an alternative visual processing pathway, non-reciprocal connections from and to a parallel pulvinar like structure of nine areas is coupled to the system. Compared to the pure feedforward model, cortico-pulvino-cortical output presents much more sensitivity to contrast and has a similar level of contrast invariance of the tuning.
The Role of Pulvinar in the Transmission of Information in the Visual Hierarchy
Cortes, Nelson; van Vreeswijk, Carl
2012-01-01
Visual receptive field (RF) attributes in visual cortex of primates have been explained mainly from cortical connections: visual RFs progress from simple to complex through cortico-cortical pathways from lower to higher levels in the visual hierarchy. This feedforward flow of information is paired with top-down processes through the feedback pathway. Although the hierarchical organization explains the spatial properties of RFs, is unclear how a non-linear transmission of activity through the visual hierarchy can yield smooth contrast response functions in all level of the hierarchy. Depending on the gain, non-linear transfer functions create either a bimodal response to contrast, or no contrast dependence of the response in the highest level of the hierarchy. One possible mechanism to regulate this transmission of visual contrast information from low to high level involves an external component that shortcuts the flow of information through the hierarchy. A candidate for this shortcut is the Pulvinar nucleus of the thalamus. To investigate representation of stimulus contrast a hierarchical model network of ten cortical areas is examined. In each level of the network, the activity from the previous layer is integrated and then non-linearly transmitted to the next level. The arrangement of interactions creates a gradient from simple to complex RFs of increasing size as one moves from lower to higher cortical levels. The visual input is modeled as a Gaussian random input, whose width codes for the contrast. This input is applied to the first area. The output activity ratio among different contrast values is analyzed for the last level to observe sensitivity to a contrast and contrast invariant tuning. For a purely cortical system, the output of the last area can be approximately contrast invariant, but the sensitivity to contrast is poor. To account for an alternative visual processing pathway, non-reciprocal connections from and to a parallel pulvinar like structure of nine areas is coupled to the system. Compared to the pure feedforward model, cortico-pulvino-cortical output presents much more sensitivity to contrast and has a similar level of contrast invariance of the tuning. PMID:22654750
Development and evaluation of a method of calibrating medical displays based on fixed adaptation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sund, Patrik, E-mail: patrik.sund@vgregion.se; Månsson, Lars Gunnar; Båth, Magnus
2015-04-15
Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrastmore » levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.« less
Werner, Louise Bruun; Flysjö, Anna; Tholstrup, Tine
2014-01-01
Background Dairy products are important in a healthy diet due to their high nutritional value; they are, however, associated with relatively large greenhouse gas emissions (GHGE) per kg product. When discussing the need to reduce the GHGE caused by the food system, it is crucial to consider the nutritional value of alternative food choices. Objective The objective of this study was to elucidate the role of dairy products in overall nutrition and to clarify the effects of dietary choices on GHGE, and to combine nutritional value and GHGE data. Methods We created eight dietary scenarios with different quantity of dairy products using data from the Danish National Dietary Survey (1995–2006). Nutrient composition and GHGE data for 71 highly consumed foods were used to estimate GHGE and nutritional status for each dietary scenario. An index was used to estimate nutrient density in relation to nutritional recommendation and climate impact for solid food items; high index values were those with the highest nutrient density scores in relation to the GHGE. Results The high-dairy scenario resulted in 27% higher protein, 13% higher vitamin D; 55% higher calcium; 48% higher riboflavin; and 18% higher selenium than the non-dairy scenario. There was a significant correlation between changes in calcium and changes in vitamin D, selenium, and riboflavin content (P=0.0001) throughout all of the diets. The estimated GHGE for the dietary scenario with average-dairy consumption was 4,631 g CO2e/day. Conclusions When optimizing a diet with regard to sustainability, it is crucial to account for the nutritional value and not solely focus on impact per kg product. Excluding dairy products from the diet does not necessarily mitigate climate change but in contrast may have nutritional consequences. PMID:24959114
Werner, Louise Bruun; Flysjö, Anna; Tholstrup, Tine
2014-01-01
Dairy products are important in a healthy diet due to their high nutritional value; they are, however, associated with relatively large greenhouse gas emissions (GHGE) per kg product. When discussing the need to reduce the GHGE caused by the food system, it is crucial to consider the nutritional value of alternative food choices. The objective of this study was to elucidate the role of dairy products in overall nutrition and to clarify the effects of dietary choices on GHGE, and to combine nutritional value and GHGE data. We created eight dietary scenarios with different quantity of dairy products using data from the Danish National Dietary Survey (1995-2006). Nutrient composition and GHGE data for 71 highly consumed foods were used to estimate GHGE and nutritional status for each dietary scenario. An index was used to estimate nutrient density in relation to nutritional recommendation and climate impact for solid food items; high index values were those with the highest nutrient density scores in relation to the GHGE. The high-dairy scenario resulted in 27% higher protein, 13% higher vitamin D; 55% higher calcium; 48% higher riboflavin; and 18% higher selenium than the non-dairy scenario. There was a significant correlation between changes in calcium and changes in vitamin D, selenium, and riboflavin content (P=0.0001) throughout all of the diets. The estimated GHGE for the dietary scenario with average-dairy consumption was 4,631 g CO2e/day. When optimizing a diet with regard to sustainability, it is crucial to account for the nutritional value and not solely focus on impact per kg product. Excluding dairy products from the diet does not necessarily mitigate climate change but in contrast may have nutritional consequences.
Sokmen, Bedriye Koyuncu; Sokmen, Dogukan; Ucar, Nese; Ozkurt, Huseyin; Simsek, Abdulmuttalip
2017-12-31
Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR) images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC) values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1) (n = 20) (Stage T1c-T2a, PSA < 10 ng/ml, Gleason Score < 7), moderate-risk (Group 2) (n = 18) (Stage T1b-T2c, PSA = 10-20 ng/ml, Gleason Score = 7) and high-risk (Group 3) (n = 22) (Stage > T3a, PSA > 20 ng/ml, Gleason Score > 7). Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. ADC values of the cases in Group 3 were lower than those of the other groups (p < 0.001). ADC values of the areas without malignancy did not differ significantly between groups (p > 0.05). Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p < 0.001). In tumors with higher Gleason scores, lower ADC values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.
Li, Feng-Lan; Zan, Qi-Jie; Hu, Zheng-Yu; Shin, Paul-K S; Cheung, Siu-Gin; Wong, Yuk-Shan; Tam, Nora Fung-Yee; Lei, An-Ping
2016-01-01
A higher photosynthesis and lower energetic cost are recognized as important characteristics for invasive species, but whether these traits are also important for the ability of alien mangrove species to become invasive has seldom been reported. A microcosm study was conducted to compare the photosynthetic characteristics, energetic cost indices and other growth traits between two alien species (Sonneratia apetala and S. caseolaris) and four native mangrove species over four seasons in a subtropical mangrove nature reserve in Shenzhen, South China. The aim of the study was to evaluate the invasive potential of Sonneratia based on these physiological responses. The annual average net photosynthetic rate (Pn), stomatal conductance (Gs) and total carbon assimilation per unit leaf area (Atotal) of the two alien Sonneratia species were significantly higher than the values of the native mangroves. In contrast, the opposite results were obtained for the leaf construction cost (CC) per unit dry mass (CCM) and CC per unit area (CCA) values. The higher Atotal and lower CC values resulted in a 72% higher photosynthetic energy-use efficiency (PEUE) for Sonneratia compared to native mangroves, leading to a higher relative growth rate (RGR) of the biomass and height of Sonneratia with the respective values being 51% and 119% higher than those of the native species. Higher photosynthetic indices for Sonneratia compared to native species were found in all seasons except winter, whereas lower CC values were found in all four seasons. The present findings reveal that alien Sonneratia species may adapt well and become invasive in subtropical mangrove wetlands in Shenzhen due to their higher photosynthetic characteristics coupled with lower costs in energy use, leading to a higher PEUE. The comparison of these physiological responses between S. apetala and S. caseolaris reveal that the former species is more invasive than the latter one, thus requiring more attention in future.
Li, Feng-Lan; Zan, Qi-Jie; Hu, Zheng-Yu; Shin, Paul-K. S.; Cheung, Siu-Gin; Wong, Yuk-Shan; Tam, Nora Fung-Yee; Lei, An-Ping
2016-01-01
A higher photosynthesis and lower energetic cost are recognized as important characteristics for invasive species, but whether these traits are also important for the ability of alien mangrove species to become invasive has seldom been reported. A microcosm study was conducted to compare the photosynthetic characteristics, energetic cost indices and other growth traits between two alien species (Sonneratia apetala and S. caseolaris) and four native mangrove species over four seasons in a subtropical mangrove nature reserve in Shenzhen, South China. The aim of the study was to evaluate the invasive potential of Sonneratia based on these physiological responses. The annual average net photosynthetic rate (Pn), stomatal conductance (Gs) and total carbon assimilation per unit leaf area (Atotal) of the two alien Sonneratia species were significantly higher than the values of the native mangroves. In contrast, the opposite results were obtained for the leaf construction cost (CC) per unit dry mass (CCM) and CC per unit area (CCA) values. The higher Atotal and lower CC values resulted in a 72% higher photosynthetic energy-use efficiency (PEUE) for Sonneratia compared to native mangroves, leading to a higher relative growth rate (RGR) of the biomass and height of Sonneratia with the respective values being 51% and 119% higher than those of the native species. Higher photosynthetic indices for Sonneratia compared to native species were found in all seasons except winter, whereas lower CC values were found in all four seasons. The present findings reveal that alien Sonneratia species may adapt well and become invasive in subtropical mangrove wetlands in Shenzhen due to their higher photosynthetic characteristics coupled with lower costs in energy use, leading to a higher PEUE. The comparison of these physiological responses between S. apetala and S. caseolaris reveal that the former species is more invasive than the latter one, thus requiring more attention in future. PMID:27286250
Huang, Yi; Liu, Dexiang; Tang, Yukuan; Fan, Zhaoyang; Chen, Hanwei; Liu, Xin
2015-01-01
Objectives To compare the image quality and diagnostic performance of two non-contrast enhanced MR angiography (NCE-MRA) techniques using flow-sensitive dephasing (FSD) prepared steady-state free precession (SSFP) and quiescent-interval single-shot (QISS) for the calf arteries in patients with diabetes. Materials and Methods Twenty six patients underwent the two NCE-MRA techniques followed by contrast-enhanced MRA (CE-MRA) of lower extremity on a 1.5T MR system. Image quality scores, arterial stenosis scores, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and diagnostic accuracy for detecting more than 50% arterial stenosis were evaluated and statistically compared using CE-MRA as the reference standard. Results All examinations were performed successfully. Of the total 153 calf arterial segments obtained in the 26 patients, FSD and QISS showed no significant difference in the number of diagnostic arterial segments (151 [98%] vs. 147 [96%], respectively, P>0.05). The image quality of FSD was higher than that of QISS in the peroneal artery and posterior tibial artery (P<0.05), but no significant difference in the anterior tibial artery (P>0.05). SNR and CNR of FSD were higher than those of QISS (P<0.01), while FSD showed comparable vessel sharpness compared with QISS (P>0.05). The time efficiency of SNR and CNR between FSD and QISS showed no significant difference when taking into account the times for FSD-related scout scans. There was no difference in sensitivity (95% vs. 93%, P>0.05) and negative predictive value (98% vs. 97%, P>0.05) between FSD and QISS for detecting stenosis greater than 50%. However, FSD showed higher specificities (99% vs. 92%, P<0.05) and diagnostic accuracy (98% vs. 92%, P<0.05) compared to QISS. Conclusion Both FSD and QISS had similar high sensitivity and negative predictive value for detecting calf arteries with over 50% stenosis, but FSD showed slightly higher diagnostic specificity and better depiction of arterial lesions due to its isotropic submillimeter spatial resolution. QISS, being an easier to use and less time-consuming technique, could be a method of choice for rapid screening of arterial disease of the lower extremity. PMID:26035645
NASA Astrophysics Data System (ADS)
Seong, Myeongsu; Phillips, Zephaniah; Mai, Phuong Minh; Yeo, Chaebeom; Song, Cheol; Lee, Kijoon; Kim, Jae Gwan
2016-02-01
A combined diffuse speckle contrast analysis (DSCA)-near-infrared spectroscopy (NIRS) system is proposed to simultaneously measure qualitative blood flow and blood oxygenation changes in human tissue. The system employs an optical switch to alternate two laser sources at two different wavelengths and a CCD camera to capture the speckle image. Therefore, an optical density can be measured from two wavelengths for NIRS measurements and a speckle contrast can be calculated for DSCA measurements. In order to validate the system, a flow phantom test and an arm occlusion protocol for arterial and venous occlusion were performed. Shorter exposure times (<1 ms) show a higher drop (between 50% and 66%) and recovery of 1/KS2 values after occlusion (approximately 150%), but longer exposure time (3 ms) shows more consistent hemodynamic changes. For four subjects, the 1/KS2 values dropped to an average of 82.1±4.0% during the occlusion period and the average recovery of 1/KS2 values after occlusion was 109.1±0.8%. There was also an approximately equivalent amplitude change in oxyhemoglobin (OHb) and deoxyhemoglobin (RHb) during arterial occlusion (max RHb=0.0085±0.0024 mM/DPF, min OHb=-0.0057±0.0044 mM/DPF). The sensitivity of the system makes it a suitable modality to observe qualitative hemodynamic trends during induced physiological changes.
NASA Astrophysics Data System (ADS)
Purnamasari, L.; Iskandar, H. H. B.; Makes, B. N.
2017-08-01
In digitized radiography techniques, adjusting the image enhancement can improve the subjective image quality by optimizing the brightness and contrast for diagnostic needs. To determine the value range of image enhancement (brightness and contrast) on chronic apical abscess and apical granuloma interpretation. 30 periapical radiographs that diagnosed chronic apical abscess and 30 that diagnosed apical granuloma were adjusted by changing brightness and contrast values. The value range of brightness and contrast adjustment that can be tolerated in radiographic interpretations of chronic apical abscess and apical granuloma spans from -10 to +10. Brightness and contrast adjustments on digital radiographs do not affect the radiographic interpretation of chronic apical abscess and apical granuloma if conducted within the value range.
Maioli, Mauro; Toso, Anna; Leoncini, Mario; Musilli, Nicola; Bellandi, Francesco; Rosner, Mitchell H; McCullough, Peter A; Ronco, Claudio
2014-04-15
The aim of this study was to evaluate the relationship between pre-procedural fluid status assessed by bioimpedance vector analysis (BIVA) and development of contrast-induced acute kidney injury (CI-AKI). Accurate fluid management in patients undergoing angiographic procedures is of critical importance in limiting the risk of CI-AKI. Therefore, establishing peri-procedural fluid volume related to increased risk of CI-AKI development is essential. We evaluated the fluid status by BIVA of 900 consecutive patients with stable coronary artery disease (CAD) immediately before coronary angiography, measuring the resistance/height (R/H) ratio and impedance/height (Z/H) vector. CI-AKI was defined as an increase in serum creatinine ≥0.5 mg/dl above baseline within 3 days after contrast administration (iodixanol). CI-AKI occurred in 54 patients (6.0%). Pre-procedural R/H ratios were significantly higher in patients with CI-AKI than without CI-AKI (395 ± 71 Ohm/m vs. 352 ± 58 Ohm/m, p = 0.001 for women; 303 ± 59 Ohm/m vs. 279 ± 45 Ohm/m, p = 0.009 for men), indicating lower fluid volume in the patients with CI-AKI. When patients were stratified according to R/H ratio, there was an almost 3-fold higher risk in patients with higher values (odds ratio [OR]: 2.9; 95% confidence interval [CI]: 1.5 to 5.5; p = 0.002). The optimal receiver-operating characteristic curve analysis threshold values of R/H ratio for predicting CI-AKI were 380 Ohm/m for women and 315 Ohm/m for men. R/H ratio above these thresholds was found to be a significant and independent predictor of CI-AKI (OR: 3.1; 95% CI: 1.8 to 5.5; p = 0.001). Lower fluid status evaluated by BIVA immediately before contrast medium administration resulted in a significant and independent predictor of CI-AKI in patients with stable CAD. This simple noninvasive analysis should be tested in guiding tailored volume repletion. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Imaging model for the scintillator and its application to digital radiography image enhancement.
Wang, Qian; Zhu, Yining; Li, Hongwei
2015-12-28
Digital Radiography (DR) images obtained by OCD-based (optical coupling detector) Micro-CT system usually suffer from low contrast. In this paper, a mathematical model is proposed to describe the image formation process in scintillator. By solving the correlative inverse problem, the quality of DR images is improved, i.e. higher contrast and spatial resolution. By analyzing the radiative transfer process of visible light in scintillator, scattering is recognized as the main factor leading to low contrast. Moreover, involved blurring effect is also concerned and described as point spread function (PSF). Based on these physical processes, the scintillator imaging model is then established. When solving the inverse problem, pre-correction to the intensity of x-rays, dark channel prior based haze removing technique, and an effective blind deblurring approach are employed. Experiments on a variety of DR images show that the proposed approach could improve the contrast of DR images dramatically as well as eliminate the blurring vision effectively. Compared with traditional contrast enhancement methods, such as CLAHE, our method could preserve the relative absorption values well.
Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.
Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E
1997-01-01
The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.
MRI contrast demonstration of antigen-specific targeting with an iron-based ferritin construct
NASA Astrophysics Data System (ADS)
Walsh, Edward G.; Mills, David R.; Lim, Sierin; Sana, Barindra; Brilliant, Kate E.; Park, William K. C.
2013-01-01
A genetically modified ferritin has been examined for its properties as a tumor-selective magnetic resonance imaging (MRI) contrast agent. The engineered ferritin described herein was derived from Archaeoglobus fulgidus (AfFtn-AA), which stores a significantly greater quantity of iron than wild-type ferritins. Relaxivity measurements were taken at 3 Tesla of ferritin particles uniformly distributed in an agarose gel to assess relaxivities r 1 and r 2. The r 1 and r 2 values of the uniformly distributed modified ferritin were significantly higher ( r 1 = 1,290 mM-1 s-1 and r 2 = 5,740 mM-1 s-1) than values observed for wild-type ferritin (e.g., horse spleen, r 1 = 0.674 mM-1 s-1, r 2 = 95.54 mM-1 s-1). The modified iron-enriched ferritin (14.5 nm diameter) was conjugated with a monoclonal antibody (10 nm length) against rat Necl-5, a cell surface glycoprotein overexpressed by many epithelial cancers. In vitro studies showed strong reactivity of the assembled nanoconjugate to transformed Necl-5 positive rat prostate epithelial cells. Furthermore, MRI demonstrated a significant T2 contrast with negligible T1 effect when bound to cells. These findings highlight the utility of the modified ferritin construct as a novel MRI contrast agent that can be manipulated to target antigen-specific tissues.
Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi
2016-01-01
To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.
Photometric Properties of Network and Faculae Derived from HMI Data Compensated for Scattered Light
NASA Astrophysics Data System (ADS)
Criscuoli, Serena; Norton, Aimee; Whitney, Taylor
2017-10-01
We report on the photometric properties of faculae and network, as observed in full-disk, scattered-light-corrected images from the Helioseismic Magnetic Imager. We use a Lucy-Richardson deconvolution routine that corrects an image in less than one second. Faculae are distinguished from network through proximity to active regions. This is the first report that full-disk observations, including center-to-limb variations, reproduce the photometric properties of faculae and network observed previously only in sub-arcsecond-resolution; small field-of-view studies, I.e. that network, as defined by distance from active regions, exhibit higher photometric contrasts. Specifically, for magnetic flux values larger than approximately 300 G, the network is brighter than faculae and the contrast differences increase toward the limb, where the network contrast is about twice the facular one. For lower magnetic flux values, network appear darker than faculae. Contrary to reports from previous full-disk observations, we also found that network exhibits a higher center-to-limb variation. Our results are in agreement with reports from simulations that indicate magnetic flux alone is a poor proxy of the photometric properties of magnetic features. We estimate that the contribution of faculae and network to Total Solar Irradiance variability of the current Cycle 24 is overestimated by at least 11%, due to the photometric properties of network and faculae not being recognized as different. This estimate is specific to the method employed in this study to reconstruct irradiance variations, so caution should be paid when extending it to other techniques.
Photometric Properties of Network and Faculae Derived from HMI Data Compensated for Scattered Light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Criscuoli, Serena; Whitney, Taylor; Norton, Aimee
We report on the photometric properties of faculae and network, as observed in full-disk, scattered-light-corrected images from the Helioseismic Magnetic Imager. We use a Lucy–Richardson deconvolution routine that corrects an image in less than one second. Faculae are distinguished from network through proximity to active regions. This is the first report that full-disk observations, including center-to-limb variations, reproduce the photometric properties of faculae and network observed previously only in sub-arcsecond-resolution; small field-of-view studies, i.e. that network, as defined by distance from active regions, exhibit higher photometric contrasts. Specifically, for magnetic flux values larger than approximately 300 G, the network ismore » brighter than faculae and the contrast differences increase toward the limb, where the network contrast is about twice the facular one. For lower magnetic flux values, network appear darker than faculae. Contrary to reports from previous full-disk observations, we also found that network exhibits a higher center-to-limb variation. Our results are in agreement with reports from simulations that indicate magnetic flux alone is a poor proxy of the photometric properties of magnetic features. We estimate that the contribution of faculae and network to Total Solar Irradiance variability of the current Cycle 24 is overestimated by at least 11%, due to the photometric properties of network and faculae not being recognized as different. This estimate is specific to the method employed in this study to reconstruct irradiance variations, so caution should be paid when extending it to other techniques.« less
NASA Astrophysics Data System (ADS)
Widianingsih, W.; Zaenuri, M.; Anggoro, S.; Kusumaningrum, H. P.; Hartati, R.
2018-03-01
The study of characteristic sediment and water column chlorophyll-a has an important role in the sea cucumber habitat. Sediment chlorophyll-a represents a productivity primer for the benthic community. This research has a purpose to investigate characteristic sediment and water column chlorophyll-a on the Kenjeran water, Surabaya. Sediment samples were collected by the ekman grab for analysis, grain size and nutrient. The sample for sediment chlorophyll-a was taken by core sampler. The water samples were taken with Nansen Bottles. According to the research result, the values of sediment chlorophyll-a at station 10, 11 and 12 were higher than the other stations. In contrast, the value of chlorophyll-a in the column water had almost the same value for each station. The sediment chlorophyll-a value on clay and silt sediment type was higher than the fine sand and coarse sediment type. The suitable habitat characteristic for Paracaudina sp. was clay and silt sediment with sediment chlorophyll concentration ranging from 347.82 mg·m-2 to 1135.52 mg·m-2.
Comparison of non-invasive MRI measurements of cerebral blood flow in a large multisite cohort.
Dolui, Sudipto; Wang, Ze; Wang, Danny Jj; Mattay, Raghav; Finkel, Mack; Elliott, Mark; Desiderio, Lisa; Inglis, Ben; Mueller, Bryon; Stafford, Randall B; Launer, Lenore J; Jacobs, David R; Bryan, R Nick; Detre, John A
2016-07-01
Arterial spin labeling and phase contrast magnetic resonance imaging provide independent non-invasive methods for measuring cerebral blood flow. We compared global cerebral blood flow measurements obtained using pseudo-continuous arterial spin labeling and phase contrast in 436 middle-aged subjects acquired at two sites in the NHLBI CARDIA multisite study. Cerebral blood flow measured by phase contrast (CBFPC: 55.76 ± 12.05 ml/100 g/min) was systematically higher (p < 0.001) and more variable than cerebral blood flow measured by pseudo-continuous arterial spin labeling (CBFPCASL: 47.70 ± 9.75). The correlation between global cerebral blood flow values obtained from the two modalities was 0.59 (p < 0.001), explaining less than half of the observed variance in cerebral blood flow estimates. Well-established correlations of global cerebral blood flow with age and sex were similarly observed in both CBFPCASL and CBFPC CBFPC also demonstrated statistically significant site differences, whereas no such differences were observed in CBFPCASL No consistent velocity-dependent effects on pseudo-continuous arterial spin labeling were observed, suggesting that pseudo-continuous labeling efficiency does not vary substantially across typical adult carotid and vertebral velocities, as has previously been suggested. Although CBFPCASL and CBFPC values show substantial similarity across the entire cohort, these data do not support calibration of CBFPCASL using CBFPC in individual subjects. The wide-ranging cerebral blood flow values obtained by both methods suggest that cerebral blood flow values are highly variable in the general population. © The Author(s) 2016.
Jurczyszyn, Kamil; Osiecka, Beata J; Ziółkowski, Piotr
2012-01-01
Fractal dimension analysis (FDA) is modern mathematical method widely used to describing of complex and chaotic shapes when classic methods fail. The main aim of this study was evaluating the influence of photodynamic therapy (PDT) with cystein proteases inhibitors (CPI) on the number and morphology of blood vessels inside tumor and on increase of effectiveness of combined therapy in contrast to PDT and CPI used separately. Animals were divided into four groups: control, treated using only PDT, treated using only CPI and treated using combined therapy, PDT and CPI. Results showed that time of animal survival and depth of necrosis inside tumor were significantly higher in CPI+PDT group in contrast to other groups. The higher value of fractal dimension (FD) was observed in control group, while the lowest value was found in the group which was treated by cystein protease inhibitors. The differences between FD were observed in CPI group and PDT+CPI group in comparison to control group. Our results revealed that fractal dimension analysis is a very useful tool in estimating differences between irregular shapes like blood vessels in PDT treated tumors. Thus, the implementation of FDA algorithms could be useful method in evaluating the efficacy of PDT.
Jurczyszyn, Kamil; Osiecka, Beata J.; Ziółkowski, Piotr
2012-01-01
Fractal dimension analysis (FDA) is modern mathematical method widely used to describing of complex and chaotic shapes when classic methods fail. The main aim of this study was evaluating the influence of photodynamic therapy (PDT) with cystein proteases inhibitors (CPI) on the number and morphology of blood vessels inside tumor and on increase of effectiveness of combined therapy in contrast to PDT and CPI used separately. Animals were divided into four groups: control, treated using only PDT, treated using only CPI and treated using combined therapy, PDT and CPI. Results showed that time of animal survival and depth of necrosis inside tumor were significantly higher in CPI+PDT group in contrast to other groups. The higher value of fractal dimension (FD) was observed in control group, while the lowest value was found in the group which was treated by cystein protease inhibitors. The differences between FD were observed in CPI group and PDT+CPI group in comparison to control group. Our results revealed that fractal dimension analysis is a very useful tool in estimating differences between irregular shapes like blood vessels in PDT treated tumors. Thus, the implementation of FDA algorithms could be useful method in evaluating the efficacy of PDT. PMID:22991578
Barbieri, Lucia; Verdoia, Monica; Marino, Paolo; Suryapranata, Harry; De Luca, Giuseppe
2016-06-01
Contrast-induced nephropathy is a common complication of procedures that are likely to use contrast media. The identification of high-risk patients and preventive optimal hydration are key measures to reduce the incidence of contrast-induced nephropathy. The aim of this study was to evaluate the role of the contrast volume to creatinine clearance ratio (V/CrCl) in the prediction of contrast-induced nephropathy after coronary angiography or percutaneous coronary intervention. Our population consisted of 2308 consecutive patients undergoing coronary angiography and/or percutaneous coronary intervention. The risk of contrast-induced nephropathy was evaluated across quartiles of the V/CrCl. Receiver operating characteristic curves were used to identify the best predictive value. Contrast-induced nephropathy was defined as an absolute increase of 0.5 mg/dL or a relative increase of >25% in creatinine levels 24-48 hours after the procedure. The total incidence of contrast-induced nephropathy was 12.2% and was significantly higher in the fourth quartile (first quartile 8.8%, second quartile 8.9%, third quartile 11.6% and fourth quartile 19.4%; P < 0.001). Using receiver operating characteristic curves we identified V/CrCl ≥ 6.15 as the best discriminant value for the prediction of contrast-induced nephropathy, which occurred in 25.1% of patients with V/CrCl ≥ 6.15 versus 9.7% in patients with V/CrCl < 6.15. These results were also confirmed at multivariate analysis after correction for all baseline confounders (adjusted odds ratio (AOR) (95% confidence interval (CI)) 1.81 (1.19-2.76); P = 0.005). The association between V/CrCl > 6.15 and an increased risk of contrast-induced nephropathy was confirmed among diabetic (11% vs. 27.7%; p P < 0.001) and non-diabetic patients (8.9% vs. 23%; Pp < 0.001), also after correction for all baseline confounders. This is one of the largest studies evaluating the association between the V/CrCl ratio and the risk of contrast-induced nephropathy in patients undergoing coronary angiography or percutaneous coronary intervention. We found that a V/CrCl ratio >6.15 was independently associated with an increased risk of contrast-induced nephropathy. © The European Society of Cardiology 2015.
Jeans instability in a universe with dissipation
NASA Astrophysics Data System (ADS)
Kremer, Gilberto M.; Richarte, Martín G.; Teston, Felipe
2018-01-01
The problem of Jeans gravitational instability is investigated for static and expanding universes within the context of the five and thirteen field theories which account for viscous and thermal effects. For the five-field theory a general dispersion relation has been derived with the help of relevant linearized perturbation equations, showing that the shear viscosity parameter alters the propagating modes for large and small wavelengths. The behavior of density and temperature contrasts are analyzed for the hard-sphere model in detail. In the small wavelengths regime, increasing the amount of shear viscosity into the system forces the harmonic perturbations to damp faster, however, in the opposite limit larger values of shear viscosity lead to smaller values of density and temperature contrasts. We also consider the hyperbolic case associated with the thirteen-field theory which involves two related parameters, namely the shear viscosity and the collision frequency, the last one is due to the production terms which appear in the Grad method. The dispersion relation becomes a polynomial in the frequency with two orders higher in relation to the five-field theory, indicating that the effects associated with the shear viscosity and heat flux are nontrivial. The profile of Jeans mass in terms of the temperature and number density is explored by contrasting with several data of molecular clouds. Regarding the dynamical evolution of the density, temperature, stress and heat flux contrasts for a universe dominated by pressureless matter, we obtain also damped harmonic waves for small wavelengths. In the case of large wavelengths, the density and temperature contrasts grow with time (due to the Jeans mechanism) while the stress and heat flux contrasts heavily decay with time. For an expanding universe, the Jeans mass and Jeans length are obtained and their physical consequences are explored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Chuanfei; Lingam, Manasvi; Ma, Yingjuan
We address the important question of whether the newly discovered exoplanet, Proxima Centauri b (PCb), is capable of retaining an atmosphere over long periods of time. This is done by adapting a sophisticated multi-species MHD model originally developed for Venus and Mars and computing the ion escape losses from PCb. The results suggest that the ion escape rates are about two orders of magnitude higher than the terrestrial planets of our Solar system if PCb is unmagnetized. In contrast, if the planet does have an intrinsic dipole magnetic field, the rates are lowered for certain values of the stellar windmore » dynamic pressure, but they are still higher than the observed values for our solar system’s terrestrial planets. These results must be interpreted with due caution since most of the relevant parameters for PCb remain partly or wholly unknown.« less
The Lα (λ = 121.6 nm) solar plage contrasts calculations.
NASA Astrophysics Data System (ADS)
Bruevich, E. A.
1991-06-01
The results of calculations of Lα plage contrasts based on experimental data are presented. A three-component model ideology of Lα solar flux using "Prognoz-10" and SME daily smoothed values of Lα solar flux are applied. The values of contrast are discussed and compared with experimental values based on "Skylab" data.
Lacerda, Eliza Maria da Costa Brito; Lima, Monica Gomes; Rodrigues, Anderson Raiol; Teixeira, Cláudio Eduardo Correa; de Lima, Lauro José Barata; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima
2012-01-01
The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction. PMID:22220188
Contrast and the justification of effort.
Klein, Emily D; Bhatt, Ramesh S; Zentall, Thomas R
2005-04-01
When humans are asked to evaluate rewards or outcomes that follow unpleasant (e.g., high-effort) events, they often assign higher value to that reward. This phenomenon has been referred to as cognitive dissonance or justification of effort. There is now evidence that a similar phenomenon can be found in nonhuman animals. When demonstrated in animals, however, it has been attributed to contrast between the unpleasant high effort and the conditioned stimulus for food. In the present experiment, we asked whether an analogous effect could be found in humans under conditions similar to those found in animals. Adult humans were trained to discriminate between shapes that followed a high-effort versus a low-effort response. In test, participants were found to prefer shapes that followed the high-effort response in training. These results suggest the possibility that contrast effects of the sort extensively studied in animals may play a role in cognitive dissonance and other related phenomena in humans.
Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin
2016-01-01
Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654
NASA Astrophysics Data System (ADS)
Sorooshian, Armin; Shingler, T.; Crosbie, E.; Barth, M. C.; Homeyer, C. R.; Campuzano-Jost, P.; Day, D. A.; Jimenez, J. L.; Thornhill, K. L.; Ziemba, L. D.; Blake, D. R.; Fried, A.
2017-04-01
We examine three case studies during the Deep Convective Clouds and Chemistry (DC3) field experiment when storm inflow and outflow air were sampled for aerosol subsaturated hygroscopicity and the real part of refractive index (n) with a Differential Aerosol Sizing and Hygroscopicity Probe (DASH-SP) on the NASA DC-8. Relative to inflow aerosol particles, outflow particles were more hygroscopic (by 0.03 based on the estimated κ parameter) in one of the three storms examined. Two of three "control" flights with no storm convection reveal higher κ values, albeit by only 0.02, at high altitude (> 8 km) versus < 4 km. Entrainment modeling shows that measured κ values in the outflow of the three storm flights are higher than predicted values (by 0.03-0.11) based on knowledge of κ values from the inflow and clear air adjacent to the storms. This suggests that other process(es) contributed to hygroscopicity enhancements such as secondary aerosol formation via aqueous-phase chemistry. Values of n were higher in the outflow of two of the three storm flights, reaching as high as 1.54. More statistically significant differences were observed in control flights (no storms) where n decreased from 1.50-1.52 (< 4 km) to 1.49-1.50 (> 8 km). Chemical data show that enhanced hygroscopicity was coincident with lower organic mass fractions, higher sulfate mass fractions, and higher O:C ratios of organic aerosol. Refractive index did not correlate as well with available chemical data. Deep convection is shown to alter aerosol radiative properties, which has implications for aerosol effects on climate.
Value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion
Zhang, Hui-Ping; Bai, Min; Gu, Ji-Ying; He, Ying-Qian; Qiao, Xiao-Hui; Du, Lian-Fang
2018-01-01
AIM To describe contrast-enhanced ultrasound (CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as (1) benign, (2) probably benign, (3) probably malignant or (4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared. RESULTS There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS (e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8% and 95.2%, respectively. These were significantly higher than conventional ultrasound (82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer. CONCLUSION CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound. PMID:29456413
Phukan, Bedika; Mukherjee, Chandan; Goswami, Upashi; Sarmah, Amrit; Mukherjee, Subhajit; Sahoo, Suban K; Moi, Sankar Ch
2018-03-05
Disclosed here are a piperazine, a pyridine, and two carboxylate groups containing pentadentate ligand H 2 pmpa and its corresponding water-soluble Mn(II) complex (1). DFT-based structural optimization implied that the complex had pentagonal bipyramidal geometry where the axial positions were occupied by two water molecules, and the equatorial plane was constituted by the ligand ON 3 O donor set. Thus, a bis(aquated) disc-like Mn(II) complex has been synthesized. The complex showed higher stability compared with Mn(II)-EDTA complex [log K MnL = 14.29(3)] and showed a very high r 1 relaxivity value of 5.88 mM -1 s -1 at 1.41 T, 25 °C, and pH = 7.4. The relaxivity value remained almost unaffected by the pH of the medium in the range of 6-10. Although the presence of 200 equiv of fluoride and bicarbonate anions did not affect the relaxivity value appreciably, an increase in the value was noticed in the presence of phosphate anion due to slow tumbling of the complex. Cell viability measurements, as well as phantom MR images using clinical MRI imager, consolidated the possible candidature of complex 1 as a positive contrast agent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Zhang, L; Fave, X
Purpose: Determine the impact of morphologic characteristics (e.g. necrosis, vascular enhancement, and cavitation) on radiomic features from contrast enhanced CT (CE-CT) in primary lung tumors. Methods: We developed an auto-segmentation algorithm to separate lung tumors on contrast-enhanced CT into cavitation (air), necrosis, tissue, and enhancing vessels using a combination of thresholding and region-growing. An auto-segmentation algorithm was also designed to identify necrosis on FDG-PET scans. Wilcoxon rank-sum tests were used to determine if significant differences existed in radiomics features (histogram-uniformity and Laplacian-of-Gaussian average) from 249 patients, found to prognostic in previous work, based on the presence/absence of morphologic features. Featuremore » values were also compared between the original tumor contours and contours excluding a specific morphologic feature. Comparison of necrosis segmentation on CE-CT versus FDG-PET was performed in 78 patients to assess for agreement using the concordance correlation coefficient (CCC). Results: Tumors with cavitation and enhancing vasculature had lower uniformity values (p = 0.001 and p = 0.03, respectively). Tumors with enhancing vasculature and necrosis had higher Laplacian-of-Gaussian average values (measure of “edges” within the tumor) (p < 0.001). Removing these tissue types from regions-of-interest did not drastically alter either radiomic feature value (all scenarios had R{sup 2} > 0.8). This suggests there may be interactions between morphologic characteristics and the radiomic feature value of tumor tissue. Comparison of necrosis volume and percent necrosis volume of tumor were found to have CCC values of 0.85 and 0.76, respectively between CE-CT and FDG-PET segmentation methods. Conclusions: Tumors with enhancing vasculature, necrosis, and cavitation have higher radiomic feature values that are associated with poor prognosis than tumors without these features. Removing these tissue types from quantitative assessment did not drastically impact radiomic feature values. High reproducibility of CE-CT segmented necrosis compared to FDG-PET segmented necrosis provides a reasonable validation of segmentation accuracy on CE-CT.« less
Automatic film processors' quality control test in Greek military hospitals.
Lymberis, C; Efstathopoulos, E P; Manetou, A; Poudridis, G
1993-04-01
The two major military radiology installations (Athens, Greece) using a total of 15 automatic film processors were assessed using the 21-step-wedge method. The results of quality control in all these processors are presented. The parameters measured under actual working conditions were base and fog, contrast and speed. Base and fog as well as speed displayed large variations with average values generally higher than acceptable, whilst contrast displayed greater stability. Developer temperature was measured daily during the test and was found to be outside the film manufacturers' recommended limits in nine of the 15 processors. In only one processor did film passing time vary on an every day basis and this was due to maloperation. Developer pH test was not part of the daily monitoring service being performed every 5 days for each film processor and found to be in the range 9-12; 10 of the 15 processors presented pH values outside the limits specified by the film manufacturers.
Bülow, Robin; Ittermann, Till; Dörr, Marcus; Poesch, Axel; Langner, Sönke; Völzke, Henry; Hosten, Norbert; Dewey, Marc
2018-03-14
Reference ranges of left ventricular (LV) parameters from cardiac magnetic resonance (CMR) were established to investigate the impact of ageing and hypertension as important determinants of cardiac structure and function. One thousand five hundred twenty-five contrast-enhanced CMRs were conducted in the Study of Health in Pomerania. LV end-diastolic volume (LVEDV), end-systolic volume (LVESV), stroke volume (LVSV), ejection fraction (LVEF), and myocardial mass (LVMM) were determined using long- and short-axis steady-state free-precession sequences. The reference population was defined as participants without late enhancement, hypertension, and prior cardiovascular diseases. Reference ranges were established by quantile regression (5th and 95th percentile) and compared with an additional sample of treated and untreated hypertensives. LV volumes in the reference population (n = 634, 300 males, 334 females, 52.1 ± 13.3 years) aged between 20-69 years were lower with higher age (p = 0.001), whereas LVEFs were higher (p ≤ 0.020). LVMM was lower only in males (p = 0.002). Compared with the reference population, hypertension was associated with lower LVEDV in males (n = 258, p ≤ 0.032). Antihypertensive therapy was associated with higher LVEF in males (n = 258, +2.5%, p = 0.002) and females (n = 180, +2.1%, p = 0.001). Population-based LV reference ranges were derived from contrast-enhanced CMR. Hypertension-related changes were identified by comparing these values with those of hypertensives, and they might be used to monitor cardiac function in these patients. • Left ventricular function changed slightly but significantly between 20-69 years. • Reference values of BSA-indexed myocardial mass decreased with age in males. • Hypertension was associated with lower LV end-diastolic volume only in males. • CMR may allow assessing remodelling related to hypertension or antihypertensive treatment.
Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M
2014-01-01
Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.
Falk, Armin; Szech, Nora
2013-05-10
The possibility that market interaction may erode moral values is a long-standing, but controversial, hypothesis in the social sciences, ethics, and philosophy. To date, empirical evidence on decay of moral values through market interaction has been scarce. We present controlled experimental evidence on how market interaction changes how human subjects value harm and damage done to third parties. In the experiment, subjects decide between either saving the life of a mouse or receiving money. We compare individual decisions to those made in a bilateral and a multilateral market. In both markets, the willingness to kill the mouse is substantially higher than in individual decisions. Furthermore, in the multilateral market, prices for life deteriorate tremendously. In contrast, for morally neutral consumption choices, differences between institutions are small.
NASA Astrophysics Data System (ADS)
Theodor, Marc; Schmiedl, Gerhard; Jorissen, Frans; Mackensen, Andreas
2016-11-01
We have determined stable carbon isotope ratios of epifaunal and shallow infaunal benthic foraminifera in the Mediterranean Sea to relate the inferred gradient of pore water δ13CDIC to varying trophic conditions. This is a prerequisite for developing this difference into a potential transfer function for organic matter flux rates. The data set is based on samples retrieved from a well-defined bathymetric range (400-1500 m water depth) of sub-basins in the western, central, and eastern Mediterranean Sea. Regional contrasts in organic matter fluxes and associated δ13CDIC of pore water are recorded by the δ13C difference (Δδ13CUmed-Epi) between the shallow infaunal Uvigerina mediterranea and epifaunal species (Planulina ariminensis, Cibicidoides pachydermus, Cibicides lobatulus). Within epifaunal taxa, the highest δ13C values are recorded for P. ariminensis, providing the best indicator for bottom water δ13CDIC. In contrast, C. pachydermus reveals minor pore water effects at the more eutrophic sites. Because of ontogenetic trends in the δ13C signal of U. mediterranea of up to 1.04 ‰, only tests larger than 600 µm were used for the development of the transfer function. The recorded differences in the δ13C values of U. mediterranea and epifaunal taxa (Δδ13CUmed-Epi) range from -0.46 to -2.13 ‰, with generally higher offsets at more eutrophic sites. The measured δ13C differences are related to site-specific differences in microhabitat, depth of the principal sedimentary redox boundary, and TOC content of the ambient sediment. The Δδ13CUmed-Epi values reveal a consistent relation to Corg fluxes estimated from satellite-derived surface water primary production in open-marine settings of the Alboran Sea, Mallorca Channel, Strait of Sicily, and southern Aegean Sea. In contrast, Δδ13CUmed-Epi values in areas affected by intense resuspension and riverine organic matter sources of the northern to central Aegean Sea and the canyon systems of the Gulf of Lion suggest higher Corg fluxes compared to the values based on recent primary production. Taking regional biases and uncertainties into account, we establish a first Δδ13CUmed-Epi-based transfer function for Corg fluxes for the Mediterranean Sea.
Intraindividual Crossover Comparison of Gadoxetic Acid Dose for Liver MRI in Normal Volunteers.
Motosugi, Utaroh; Bannas, Peter; Hernando, Diego; Salmani Rahimi, Mahdi; Holmes, James H; Reeder, Scott B
2016-01-01
We performed a quantitative intraindividual comparison of the performance of 0.025- and 0.05-mmol/kg doses for gadoxetic acid-enhanced liver magnetic resonance (MR) imaging. Eleven healthy volunteers underwent liver MR imaging twice, once with a 0.025- and once with a 0.05-mmol/kg dose of gadoxetic acid. MR spectroscopy and 3-dimensional gradient-echo T1-weighted images (3D-GRE) were obtained before and 3, 10, and 20 min after injection of the contrast medium to measure T1 and T2 values and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) performance. During the dynamic phase, highly time-resolved 3D-GRE was used to estimate the relative CNR (CNRrel) of the hepatic artery and portal vein (PV) to the liver. We used paired t-tests to compare the results of different doses. During the hepatobiliary phase, we observed shorter T1 values and higher SNRs of the liver (P < 0.001) and higher liver-to-PV and liver-to-muscle CNRs (P < 0.002) using 0.05 mmol/kg compared to 0.025 mmol/kg. Increasing the dose to 0.05 mmol/kg yielded a greater T1-shortening effect at 10 min delay even compared with 0.025 mmol/kg at 20 min (P < 0.001). During the dynamic phase, the peak CNRrel for the hepatic artery and portal vein were higher using 0.05 mmol/kg (P = 0.007 to 0.035). Use of gadoxetic acid at a dose of 0.05 mmol/kg leads to significantly higher SNR and CNR performance than with 0.025 mmol/kg. Quantitatively, a 10-min delay may be feasible for hepatobiliary-phase imaging when using 0.05 mmol/kg of gadoxetic acid.
Noordam, Raymond; Hamer, Merel A; Pardo, Luba M; van der Nat, Tamara; Kiefte-de Jong, Jessica C; Kayser, Manfred; Slagboom, P Eline; Uitterlinden, André; Zillikens, M Carola; Beekman, Marian; Nijsten, Tamar; van Heemst, Diana; Gunn, David A
2017-11-01
Data from in vitro experiments suggest that vitamin D reduces the rate of skin aging, whereas population studies suggest the opposite, most likely due to confounding by UV exposure. We investigated whether there are causal associations between 25-hydroxyvitamin D concentrations and features of skin aging in a bidirectional Mendelian randomization study. In the Rotterdam Study (N = 3,831; 58.2% women, median age 66.5 years) and Leiden Longevity Study (N = 661; 50.5% women, median age 63.1 years), facial skin aging features (perceived age, wrinkling, pigmented spots) were assessed either manually or digitally. Associations between 25-hydroxyvitamin D and skin aging features were tested by multivariable linear regression. Mendelian randomization analyses were performed using single nucleotide polymorphisms identified from previous genome-wide association studies. After meta-analysis of the two cohorts, we observed that higher serum 25-hydroxyvitamin D was associated with a higher perceived age (P-value = 3.6 × 10 -7 ), more skin wrinkling (P-value = 2.6 × 10 -16 ), but not with more pigmented spots (P-value = 0.30). In contrast, a genetically determined 25-hydroxyvitamin D concentration was not associated with any skin aging feature (P-values > 0.05). Furthermore, a genetically determined higher degree of pigmented spots was not associated with higher 25-hydroxyvitamin D (P-values > 0.05). Our study did not indicate that associations between 25-hydroxyvitamin D and features of skin aging are causal. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
The importance of bulk density determination in gravity data processing for structure interpretation
NASA Astrophysics Data System (ADS)
Wildan, D.; Akbar, A. M.; Novranza, K. M. S.; Sobirin, R.; Permadi, A. N.; Supriyanto
2017-07-01
Gravity method use rock density variation for determining subsurface lithology and geological structure. In the "green area" where measurement of rock density has not been done, an attemp to find density is usually performed by calculating using Parasnis method, or by using using the average of rock density in the earth's crust (2,67 gr/cm3) or by using theoritical value of dominant rock density in the survey area (2,90 gr/cm3). Those three values of densities are applied to gravity data analysis in the hilly "X" area. And we have compared all together in order to observed which value has represented the structure better. The result showed that the higher value of rock density, the more obvious structure in the Bouguer anomaly profile. It is due to the contrast of maximum and minimum value of Bouguer anomaly that will affect the exageration in distance vs Bouguer anomaly graphic.
Speckle reduction using deformable mirrors with diffusers in a laser pico-projector.
Chen, Hsuan-An; Pan, Jui-Wen; Yang, Zu-Po
2017-07-24
We propose a design for speckle reduction in a laser pico-projector adopting diffusers and deformable mirrors. This research focuses on speckle noise suppression by changing the angle of divergence of the diffuser. Moreover, the speckle contrast value can be further reduced by the addition of a deformable mirror. The speckle reduction ability obtained using diffusers with different divergence angles is compared. Three types of diffuser designs are compared in the experiments. For Type 1 which uses a circular symmetric diffuser the speckle contrast value can be decreased to 0.0264. For Type 2, the speckle contrast value can be reduced to 0.0267 because of the inclusion of an elliptical distribution diffuser. With Type 3 which includes a combination of the circular distribution diffuser and elliptical distribution diffuser, the speckle contrast value can be reduced to 0.0236. For all three types, the speckle contrast value is lower than 0.05. Under this speckle value, the speckle phenomenon is invisible to the human eye.
Neutrophil-lymphocyte ratio: a new predictive and prognostic factor in patients with Bell palsy.
Özler, Gül Soylu; Günak, Güldem
2014-05-01
The aim of this study was to investigate whether neutrophil-lymphocyte ratio (NLR) levels are elevated in patients with Bell palsy (BP). Moreover, we aimed to find out whether there is a correlation between NLR levels and the severity and prognosis of BP. The study group consisted of 25 subjects who presented with BP and 25 control subjects with no evidence of facial nerve pathology. The subjects underwent a general physical examination; an assessment of laboratory blood parameters; and a cranial magnetic resonance imaging, using gadolinium as a contrast medium. The mean (SD) NLR values were 2.16 (0.80) in the patients with BP and 1.36 (0.48) in the control group. The mean NLR values in the patients with BP were significantly higher than in the control group (P = 0.0001). There was a positive correlation between NLR values and grade of facial paralysis (r = 0.661, P = 0.0001). The mean (SD) NLR values in the grades III, IV, V, and VI BP groups were 1.40 (0.54), 1.78 (0.44), 3.00 (0.63), and 2.60 (0.54), respectively. The mean NLR values in the grade V BP group were significantly higher than in the other groups (P = 0.0001). In addition, there was a positive correlation between NLR values and prognosis of facial paralysis (r = 0.239, P = 0.251). There is no previous study that investigated the association between NLR and BP in the literature. Higher NLR values in patients with BP may be a predictor of worse prognosis.
Textural feature calculated from segmental fluences as a modulation index for VMAT.
Park, So-Yeon; Park, Jong Min; Kim, Jung-In; Kim, Hyoungnyoun; Kim, Il Han; Ye, Sung-Joon
2015-12-01
Textural features calculated from various segmental fluences of volumetric modulated arc therapy (VMAT) plans were optimized to enhance its performance to predict plan delivery accuracy. Twenty prostate and twenty head and neck VMAT plans were selected retrospectively. Fluences were generated for each VMAT plan by summations of segments at sequential groups of control points. The numbers of summed segments were 5, 10, 20, 45, 90, 178 and 356. For each fluence, we investigated 6 textural features: angular second moment, inverse difference moment, contrast, variance, correlation and entropy (particular displacement distances, d = 1, 5 and 10). Spearman's rank correlation coefficients (rs) were calculated between each textural feature and several different measures of VMAT delivery accuracy. The values of rs of contrast (d = 10) with 10 segments to both global and local gamma passing rates with 2%/2 mm were 0.666 (p <0.001) and 0.573 (p <0.001), respectively. It showed rs values of -0.895 (p <0.001) and 0.727 (p <0.001) to multi-leaf collimator positional errors and gantry angle errors during delivery, respectively. The number of statistically significant rs values (p <0.05) to the changes in dose-volumetric parameters during delivery was 14 among a total of 35 tested parameters. Contrast (d = 10) with 10 segments showed higher correlations to the VMAT delivery accuracy than did the conventional modulation indices. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
High energy x-ray phase contrast CT using glancing-angle grating interferometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarapata, A., E-mail: adrian.sarapata@tum.de; Stayman, J. W.; Siewerdsen, J. H.
Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code themore » authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.« less
Altan, Mesut; Çitamak, Burak; Bozaci, Ali Cansu; Güneş, Altan; Doğan, Hasan Serkan; Haliloğlu, Mithat; Tekgül, Serdar
2017-10-01
Many studies have been performed on adult patients to reveal the relationship between Hounsfield unit (HU) value and composition of stone, but none have focused on childhood. We aimed to predict stone composition by HU properties in pre-intervention non-contrast computed tomography (NCCT) in children. This could help to orient patients towards more successful interventions. Data of 94 children, whose pre-intervention NCCT and post-interventional stone analysis were available were included. Stones were grouped into three groups: calcium oxalate (CaOx), cystine, and struvite. Besides spot urine PH value, core HU, periphery HU, and Hounsfield density (HUD) values were measured and groups were compared statistically. The mean age of patients was 7 ± 4 (2-17) years and the female/male ratio was 51/43. The mean stone size was 11.7 ± 5 (4-24) mm. There were 50, 38, and 6 patients in the CaOx, cystine, and struvite groups, respectively. The median values for core HU, periphery HU, and mean HU in the CaOx group were significantly higher than the corresponding median values in the cystine and struvite groups. Significant median HUD difference was seen only between the CaOx and cystine groups. No difference was seen between the cystine and struvite groups in terms of HU parameters. To distinguish these groups, mean spot urine PH values were compared and were found to be higher in the struvite group than the cystine group (Table). The retrospective nature and small number of patients in some groups are limitations of this study, which also does not include all stone compositions. Our cystine stone rate was higher than childhood stone composition distribution in the literature. This is because our center is a reference center in a region with high recurrence rates of cystine stones. In fact, high numbers of cystine stones helped us to compare them with calcium stones more accurately and became an advantage for this study. NCCT at diagnosis can provide some information for determination of stone composition. While CaOx stones can be discriminated from cystine and struvite stones using HU parameters, a simple spot urine pH assessment must be added to distinguish cystine stones from struvite stones. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rios Velazquez, E; Meier, R; Dunn, W
Purpose: Reproducible definition and quantification of imaging biomarkers is essential. We evaluated a fully automatic MR-based segmentation method by comparing it to manually defined sub-volumes by experienced radiologists in the TCGA-GBM dataset, in terms of sub-volume prognosis and association with VASARI features. Methods: MRI sets of 67 GBM patients were downloaded from the Cancer Imaging archive. GBM sub-compartments were defined manually and automatically using the Brain Tumor Image Analysis (BraTumIA), including necrosis, edema, contrast enhancing and non-enhancing tumor. Spearman’s correlation was used to evaluate the agreement with VASARI features. Prognostic significance was assessed using the C-index. Results: Auto-segmented sub-volumes showedmore » high agreement with manually delineated volumes (range (r): 0.65 – 0.91). Also showed higher correlation with VASARI features (auto r = 0.35, 0.60 and 0.59; manual r = 0.29, 0.50, 0.43, for contrast-enhancing, necrosis and edema, respectively). The contrast-enhancing volume and post-contrast abnormal volume showed the highest C-index (0.73 and 0.72), comparable to manually defined volumes (p = 0.22 and p = 0.07, respectively). The non-enhancing region defined by BraTumIA showed a significantly higher prognostic value (CI = 0.71) than the edema (CI = 0.60), both of which could not be distinguished by manual delineation. Conclusion: BraTumIA tumor sub-compartments showed higher correlation with VASARI data, and equivalent performance in terms of prognosis compared to manual sub-volumes. This method can enable more reproducible definition and quantification of imaging based biomarkers and has a large potential in high-throughput medical imaging research.« less
Adaptive image inversion of contrast 3D echocardiography for enabling automated analysis.
Shaheen, Anjuman; Rajpoot, Kashif
2015-08-01
Contrast 3D echocardiography (C3DE) is commonly used to enhance the visual quality of ultrasound images in comparison with non-contrast 3D echocardiography (3DE). Although the image quality in C3DE is perceived to be improved for visual analysis, however it actually deteriorates for the purpose of automatic or semi-automatic analysis due to higher speckle noise and intensity inhomogeneity. Therefore, the LV endocardial feature extraction and segmentation from the C3DE images remains a challenging problem. To address this challenge, this work proposes an adaptive pre-processing method to invert the appearance of C3DE image. The image inversion is based on an image intensity threshold value which is automatically estimated through image histogram analysis. In the inverted appearance, the LV cavity appears dark while the myocardium appears bright thus making it similar in appearance to a 3DE image. Moreover, the resulting inverted image has high contrast and low noise appearance, yielding strong LV endocardium boundary and facilitating feature extraction for segmentation. Our results demonstrate that the inverse appearance of contrast image enables the subsequent LV segmentation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lee, Chulsung; Lee, Dustin; Darling, Cynthia L; Fried, Daniel
2010-01-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310 nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study is to determine whether the lesion contrast derived from NIR imaging in both transmission and reflectance can be used to estimate lesion severity. Two NIR imaging detector technologies are investigated: a new Ge-enhanced complementary metal-oxide-semiconductor (CMOS)-based NIR imaging camera, and an InGaAs focal plane array (FPA). Natural occlusal caries lesions are imaged with both cameras at 1310 nm, and the image contrast between sound and carious regions is calculated. After NIR imaging, teeth are sectioned and examined using polarized light microscopy (PLM) and transverse microradiography (TMR) to determine lesion severity. Lesions are then classified into four categories according to lesion severity. Lesion contrast increases significantly with lesion severity for both cameras (p<0.05). The Ge-enhanced CMOS camera equipped with the larger array and smaller pixels yields higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
In vitro near-infrared imaging of occlusal dental caries using a germanium-enhanced CMOS camera
NASA Astrophysics Data System (ADS)
Lee, Chulsung; Darling, Cynthia L.; Fried, Daniel
2010-02-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310-nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study was to determine whether the lesion contrast derived from NIR transillumination can be used to estimate lesion severity. Another aim was to compare the performance of a new Ge enhanced complementary metal-oxide-semiconductor (CMOS) based NIR imaging camera with the InGaAs focal plane array (FPA). Extracted human teeth (n=52) with natural occlusal caries were imaged with both cameras at 1310-nm and the image contrast between sound and carious regions was calculated. After NIR imaging, teeth were sectioned and examined using more established methods, namely polarized light microscopy (PLM) and transverse microradiography (TMR) to calculate lesion severity. Lesions were then classified into 4 categories according to the lesion severity. Lesion contrast increased significantly with lesion severity for both cameras (p<0.05). The Ge enhanced CMOS camera equipped with the larger array and smaller pixels yielded higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
Lee, Chulsung; Lee, Dustin; Darling, Cynthia L.; Fried, Daniel
2010-01-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310 nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study is to determine whether the lesion contrast derived from NIR imaging in both transmission and reflectance can be used to estimate lesion severity. Two NIR imaging detector technologies are investigated: a new Ge-enhanced complementary metal-oxide-semiconductor (CMOS)-based NIR imaging camera, and an InGaAs focal plane array (FPA). Natural occlusal caries lesions are imaged with both cameras at 1310 nm, and the image contrast between sound and carious regions is calculated. After NIR imaging, teeth are sectioned and examined using polarized light microscopy (PLM) and transverse microradiography (TMR) to determine lesion severity. Lesions are then classified into four categories according to lesion severity. Lesion contrast increases significantly with lesion severity for both cameras (p<0.05). The Ge-enhanced CMOS camera equipped with the larger array and smaller pixels yields higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity. PMID:20799842
NASA Astrophysics Data System (ADS)
Lee, Chulsung; Lee, Dustin; Darling, Cynthia L.; Fried, Daniel
2010-07-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310 nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study is to determine whether the lesion contrast derived from NIR imaging in both transmission and reflectance can be used to estimate lesion severity. Two NIR imaging detector technologies are investigated: a new Ge-enhanced complementary metal-oxide-semiconductor (CMOS)-based NIR imaging camera, and an InGaAs focal plane array (FPA). Natural occlusal caries lesions are imaged with both cameras at 1310 nm, and the image contrast between sound and carious regions is calculated. After NIR imaging, teeth are sectioned and examined using polarized light microscopy (PLM) and transverse microradiography (TMR) to determine lesion severity. Lesions are then classified into four categories according to lesion severity. Lesion contrast increases significantly with lesion severity for both cameras (p<0.05). The Ge-enhanced CMOS camera equipped with the larger array and smaller pixels yields higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
In vitro near-infrared imaging of occlusal dental caries using germanium enhanced CMOS camera.
Lee, Chulsung; Darling, Cynthia L; Fried, Daniel
2010-03-01
The high transparency of dental enamel in the near-infrared (NIR) at 1310-nm can be exploited for imaging dental caries without the use of ionizing radiation. The objective of this study was to determine whether the lesion contrast derived from NIR transillumination can be used to estimate lesion severity. Another aim was to compare the performance of a new Ge enhanced complementary metal-oxide-semiconductor (CMOS) based NIR imaging camera with the InGaAs focal plane array (FPA). Extracted human teeth (n=52) with natural occlusal caries were imaged with both cameras at 1310-nm and the image contrast between sound and carious regions was calculated. After NIR imaging, teeth were sectioned and examined using more established methods, namely polarized light microscopy (PLM) and transverse microradiography (TMR) to calculate lesion severity. Lesions were then classified into 4 categories according to the lesion severity. Lesion contrast increased significantly with lesion severity for both cameras (p<0.05). The Ge enhanced CMOS camera equipped with the larger array and smaller pixels yielded higher contrast values compared with the smaller InGaAs FPA (p<0.01). Results demonstrate that NIR lesion contrast can be used to estimate lesion severity.
Tolerance limit value of brightness and contrast adjustment on digitized radiographs
NASA Astrophysics Data System (ADS)
Utami, S. N.; Kiswanjaya, B.; Syahraini, S. I.; Ustriyana, P.
2017-08-01
The aim of this study was to measure the tolerance limit value of brightness and contrast adjustment on digitized radiograph with apical periodontitis and early apical abscess. Brightness and contrast adjustment on 60 periapical radiograph with apical periodontitis and early apical abscess made by 2 observers. Reliabilities tested by Cohen’s Kappa Coefficient and significance tested by wilcoxon test. Tolerance limit value of brightness and contrast adjustment for apical periodontitis is -5 and +5, early apical abscess is -10 and +10, and both is -5 and +5. Brightness and contrast adjustment which not appropriate can alter the evaluation and differential diagnosis of periapical lesion.
A study of poplar organosolv lignin after melt rheology treatment as carbon fiber precursors
Sun, Qining; Khunsupat, Ratayakorn; Akato, Kokouvi; ...
2016-06-16
Lignins from various poplar genotypes were isolated by using organosolv fractionation and subjected to rheological treatment at various temperatures. Physicochemical characterization of the lignin variants shows a broad distribution of glass transition temperatures, melt viscosity, and pyrolysis char residues. Rheological treatment at 170 °C induces lignin repolymerization accompanied with an increase in condensed linkages, molecular weights, and viscosities. In contrast, rheology testing at 190 °C results in the decrease in lignin aliphatic and phenolic hydroxyl groups, β-O-aryl ether linkages, molecular weights, and viscosity values. Lignin under air cooling generates more oxygenated and condensed compounds, but lower amounts of ether linkagesmore » than lignin cooled under nitrogen. Here, lignin with a lower syringyl/guaiacyl ratio tends to form more cross-linkages along with higher viscosity values, higher molecular weight and larger amounts of condensed bonds.« less
Changes in metal contents in shrimp cultured in NW Mexico (2000-2010).
Frías-Espericueta, M G; Osuna-López, J I; Delgado-Alvarez, C G; Muy-Rangel, M D; López-López, G; Izaguirre-Fierro, G; Jaimes-Bustamante, F; Zazueta-Padilla, H M; Aguilar-Juárez, M; Rubio-Carrasco, W; Voltolina, D
2015-05-01
This study shows the concentrations of Cd, Cu, Pb, and Zn in the muscle and hepatopancreas of Pacific white shrimps, Litopenaeus vannamei, cultured during 2010 in 26 commercial farms of the three main producer states of the Mexican NW, Sonora, Sinaloa, and Nayarit and compares the results to those obtained in 2000 using samples collected in16 farms of the same states. No significant changes were detected in Cd concentrations, but the 2010 Zn levels were significantly higher in all states in the hepatopancreas and in Sinaloa in the case of the muscle. Cu showed a tendency to higher hepatopancreas values in 2010, but differences were significant only in Sonora and for the global mean value. In contrast, Pb was one order of magnitude lower in both organs in 2010, possibly because of the almost 15 years since leaded gasoline was discontinued in Mexico.
Application of stable isotope analysis for detecting filial cannibalism.
Sogabe, Atsushi; Hamaoka, Hideki; Fukuta, Atsushi; Shibata, Jun-Ya; Shoji, Jun; Omori, Koji
2017-07-01
A novel type of filial cannibalism has been reported in pipefishes, in which the eggs are absorbed through the male's brood-pouch epithelium. The present study explored the applicability of stable isotope analysis for the detection of paternal brood cannibalism in the seaweed pipefish Syngnathus schlegeli. As expected, the δ 15 N values for liver, which conveys short-term dietary information about the recent reproductive season, were higher in males than in females. In contrast, the δ 15 N values for muscle, which reflects longer-term feeding habits that span both the reproductive and non-reproductive seasons, did not significantly differ between the sexes. This finding indicates that males occupy a higher trophic position than females only during the reproductive season, and it is probable that this difference is a result of paternal uptake of nutrients from embryos in the brood pouch. Copyright © 2017 Elsevier B.V. All rights reserved.
Striatal Activity and Reward Relativity: Neural Signals Encoding Dynamic Outcome Valuation
Webber, Emily S.; Mankin, David E.
2016-01-01
Abstract The striatum is a key brain region involved in reward processing. Striatal activity has been linked to encoding reward magnitude and integrating diverse reward outcome information. Recent work has supported the involvement of striatum in the valuation of outcomes. The present work extends this idea by examining striatal activity during dynamic shifts in value that include different levels and directions of magnitude disparity. A novel task was used to produce diverse relative reward effects on a chain of instrumental action. Rats (Rattus norvegicus) were trained to respond to cues associated with specific outcomes varying by food pellet magnitude. Animals were exposed to single-outcome sessions followed by mixed-outcome sessions, and neural activity was compared among identical outcome trials from the different behavioral contexts. Results recording striatal activity show that neural responses to different task elements reflect incentive contrast as well as other relative effects that involve generalization between outcomes or possible influences of outcome variety. The activity that was most prevalent was linked to food consumption and post-food consumption periods. Relative encoding was sensitive to magnitude disparity. A within-session analysis showed strong contrast effects that were dependent upon the outcome received in the immediately preceding trial. Significantly higher numbers of responses were found in ventral striatum linked to relative outcome effects. Our results support the idea that relative value can incorporate diverse relationships, including comparisons from specific individual outcomes to general behavioral contexts. The striatum contains these diverse relative processes, possibly enabling both a higher information yield concerning value shifts and a greater behavioral flexibility. PMID:27822506
Sorace, Anna G; Partridge, Savannah C; Li, Xia; Virostko, Jack; Barnes, Stephanie L; Hippe, Daniel S; Huang, Wei; Yankeelov, Thomas E
2018-01-01
Comparative preliminary analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data collected in the International Breast MR Consortium 6883 multicenter trial was performed to distinguish benign and malignant breast tumors. Prebiopsy DCE-MRI data from 45 patients with suspicious breast lesions were obtained. Semiquantitative mean signal-enhancement ratio ([Formula: see text]) was calculated for all lesions, and quantitative pharmacokinetic, parameters [Formula: see text], [Formula: see text], and [Formula: see text], were calculated for the subset with available [Formula: see text] maps ([Formula: see text]). Diagnostic performance was estimated for DCE-MRI parameters and compared to standard clinical MRI assessment. Quantitative and semiquantitative metrics discriminated benign and malignant lesions, with receiver operating characteristic area under the curve (AUC) values of 0.71, 0.70, and 0.82 for [Formula: see text], [Formula: see text], and [Formula: see text], respectively ([Formula: see text]). At equal 94% sensitivity, the specificity and positive predictive value of [Formula: see text] (53% and 63%, respectively) and K trans (42% and 58%) were higher than clinical MRI assessment (32% and 54%). A multivariable model combining [Formula: see text] and clinical MRI assessment had an AUC value of 0.87. Quantitative pharmacokinetic and semiquantitative analyses of DCE-MRI improves discrimination of benign and malignant breast tumors, with our findings suggesting higher diagnostic accuracy using [Formula: see text]. [Formula: see text] has potential to help reduce unnecessary biopsies resulting from routine breast imaging.
Striatal Activity and Reward Relativity: Neural Signals Encoding Dynamic Outcome Valuation.
Webber, Emily S; Mankin, David E; Cromwell, Howard C
2016-01-01
The striatum is a key brain region involved in reward processing. Striatal activity has been linked to encoding reward magnitude and integrating diverse reward outcome information. Recent work has supported the involvement of striatum in the valuation of outcomes. The present work extends this idea by examining striatal activity during dynamic shifts in value that include different levels and directions of magnitude disparity. A novel task was used to produce diverse relative reward effects on a chain of instrumental action. Rats ( Rattus norvegicus ) were trained to respond to cues associated with specific outcomes varying by food pellet magnitude. Animals were exposed to single-outcome sessions followed by mixed-outcome sessions, and neural activity was compared among identical outcome trials from the different behavioral contexts. Results recording striatal activity show that neural responses to different task elements reflect incentive contrast as well as other relative effects that involve generalization between outcomes or possible influences of outcome variety. The activity that was most prevalent was linked to food consumption and post-food consumption periods. Relative encoding was sensitive to magnitude disparity. A within-session analysis showed strong contrast effects that were dependent upon the outcome received in the immediately preceding trial. Significantly higher numbers of responses were found in ventral striatum linked to relative outcome effects. Our results support the idea that relative value can incorporate diverse relationships, including comparisons from specific individual outcomes to general behavioral contexts. The striatum contains these diverse relative processes, possibly enabling both a higher information yield concerning value shifts and a greater behavioral flexibility.
Non-contrast-enhanced MRA of renal artery stenosis: validation against DSA in a porcine model.
Bley, T A; François, C J; Schiebler, M L; Wieben, O; Takei, N; Brittain, J H; Del Rio, A Munoz; Grist, T M; Reeder, S B
2016-02-01
To compare 3D-inversion-recovery balanced steady-state free precession (IR-bSSFP) non-contrast-enhanced magnetic resonance angiography (MRA) with 3D-contrast-enhanced MRA (CE-MRA) for assessment of renal artery stenosis (RAS) using digital subtraction angiography (DSA) as the reference standard. Bilateral RAS were surgically created in 12 swine. IR-bSSFP and CE-MRA were acquired at 1.5 T and compared to rotational DSA. Three experienced cardiovascular radiologists evaluated the IR-bSSFP and CE-MRA studies independently. Linear regression models were used to calibrate and assess the accuracy of IR-bSSFP and CE-MRA, separately, against DSA. The coefficient of determination and Cohen's kappa coefficient were also generated. Calibration of the three readers' RAS grading revealed R(2) values of 0.52, 0.37 and 0.59 for NCE-MRA and 0.48, 0.53 and 0.71 for CE-MRA. Inter-rater agreement demonstrated Cohen's kappa values ranging from 0.25 to 0.65. Distal renal artery branch vessels were visible to a significantly higher degree with NCE-MRA compared to CE-MRA (p < 0.001). Image quality was rated excellent for both sequences, although image noise was higher with CE-MRA (p < 0.05). In no cases did noise interfere with image interpretation. In a well-controlled animal model of surgically induced RAS, IR-bSSFP based NCE-MRA and CE-MRA accurately graded RAS with a tendency for stenosis overestimation, compared to DSA. • IR-bSSFP and CE-MRA are accurate methods for diagnosis of renal artery stenosis • IR-bSSFP and CE-MRA demonstrate excellent agreement with DSA • Both IR-bSSFP and CE-MRA have a tendency to overestimate renal artery stenosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeng, Q.-S.; Li, C.-F.; Liu Hong
2007-05-01
Purpose: The aim of this study was to explore the diagnostic effectiveness of magnetic resonance (MR) spectroscopy with diffusion-weighted imaging on the evaluation of the recurrent contrast-enhancing areas at the site of treated gliomas. Methods and Materials: In 55 patients who had new contrast-enhancing lesions in the vicinity of the previously resected and irradiated high-grade gliomas, two-dimensional MR spectroscopy and diffusion-weighted imaging were performed. Spectral data for N-acetylaspartate (NAA), choline (Cho), creatine (Cr), lipid (Lip), and lactate (Lac) were analyzed in conjunction with the apparent diffusion coefficient (ADC) in all patients. Diagnosis of these lesions was assigned by means ofmore » follow-up or histopathology. Results: The Cho/NAA and Cho/Cr ratios were significantly higher in recurrent tumor than in regions of radiation injury (p < 0.01). The ADC value and ADC ratios (ADC of contrast-enhancing lesion to matching structure in the contralateral hemisphere) were significantly higher in radiation injury regions than in recurrent tumor (p < 0.01). With MR spectroscopic data, two variables (Cho/NAA and Cho/Cr ratios) were shown to differentiate recurrent glioma from radiation injury, and 85.5% of total subjects were correctly classified into groups. However, with discriminant analysis of MR spectroscopy imaging plus diffusion-weighted imaging, three variables (Cho/NAA, Cho/Cr, and ADC ratio) were identified and 96.4% of total subjects were correctly classified. There was a significant difference between the diagnostic accuracy of the two discriminant analyses (Chi-square = 3.96, p = 0.046). Conclusion: Using discriminant analysis, this study found that MR spectroscopy in combination with ADC ratio, rather than ADC value, can improve the ability to differentiate recurrent glioma and radiation injury.« less
Li, Huan-Huan; Zhu, Hui; Yue, Lei; Fu, Yi; Grimm, Robert; Stemmer, Alto; Fu, Cai-Xia; Peng, Wei-Jun
2018-05-01
To investigate the feasibility and diagnostic value of free-breathing, radial, stack-of-stars three-dimensional (3D) gradient echo (GRE) sequence ("golden angle") on dynamic contrast-enhanced (DCE) MRI of gastric cancer. Forty-three gastric cancer patients were divided into cooperative and uncooperative groups. Respiratory fluctuation was observed using an abdominal respiratory gating sensor. Those who breath-held for more than 15 s were placed in the cooperative group and the remainder in the uncooperative group. The 3-T MRI scanning protocol included 3D GRE and conventional breath-hold VIBE (volume-interpolated breath-hold examination) sequences, comparing images quantitatively and qualitatively. DCE-MRI parameters from VIBE images of normal gastric wall and malignant lesions were compared. For uncooperative patients, 3D GRE scored higher qualitatively, and had higher SNRs (signal-to-noise ratios) and CNRs (contrast-to-noise ratios) than conventional VIBE quantitatively. Though 3D GRE images scored lower in qualitative parameters compared with conventional VIBE for cooperative patients, it provided images with fewer artefacts. DCE parameters differed significantly between normal gastric wall and lesions, with higher Ve (extracellular volume) and lower Kep (reflux constant) in gastric cancer. The free-breathing, golden-angle, radial stack-of-stars 3D GRE technique is feasible for DCE-MRI of gastric cancer. Dynamic enhanced images can be used for quantitative analysis of this malignancy. • Golden-angle radial stack-of-stars VIBE aids gastric cancer MRI diagnosis. • The 3D GRE technique is suitable for patients unable to suspend respiration. • Method scored higher in the qualitative evaluation for uncooperative patients. • The technique produced images with fewer artefacts than conventional VIBE sequence. • Dynamic enhanced images can be used for quantitative analysis of gastric cancer.
[Contrast agent improves diagnostic value of dobutamine stress echocardiography].
Uehara, H; Yamamoto, T; Hirano, Y; Ozasa, Y; Yamada, S; Ikawa, H; Ishikawa, K
2001-03-01
Suboptimal endocardial definition reduces the diagnostic value of stress echocardiography for coronary artery disease, but intravenous infusion of a left ventricular contrast agent (Albunex) may enhance endocardial border delineation and improve the diagnostic value of dobutamine stress echocardiography. Fifty-six patients, 38 with myocardial infarction, 16 with angina pectoris and two normal subjects, were enrolled in this study. Dobutamine was infused in scalar doses of 5 to 40 micrograms/kg/min. Intravenous infusion of Albunex (0.15 ml/kg) was administered at rest and during peak dobutamine stress during monitoring of the apical four-chamber view. The left ventricle in the apical four-chamber view was divided into six segments and an endocardial delineation score of 0 to 3 (none to excellent visualization) was given to each segment. Endocardial delineation score was increased after Albunex infusion from 2.0 to 2.3 in the basal-septal, 2.0 to 2.4 in the mid-septal, 1.1 to 1.8 in the apical-septal, 0.7 to 1.2 in the apical-lateral, 0.9 to 1.6 in the mid-lateral, and 1.2 to 1.9 in the basal-lateral segments during peak dobutamine administration. Endocardial border resolution in the lateral wall showed greater improvement than in the septal wall after Albunex infusion. Diagnostic values in the left anterior descending artery territory failed to improve with Albunex infusion (sensitivity 82% to 89%, specificity 94% to 89%, and accuracy 86% to 89%), whereas a higher diagnostic accuracy was noted in the left circumflex artery territory with Albunex compared to without Albunex (sensitivity 63% to 81%, specificity 88% to 98%, and accuracy 80% to 93%, p < 0.05). Contrast agent improves the diagnostic accuracy of dobutamine stress echocardiography in the left circumflex artery territory.
NASA Astrophysics Data System (ADS)
Yang, Guang; Li, Chaolun; Guilini, Katja; Peng, Quancai; Wang, Yanqing; Zhang, Ye; Zhang, Yongshan
2016-08-01
Using fatty acid biomarkers and stable isotopic signatures, we investigated the feeding strategies and dietary preferences of four dominant copepod species (Calanoides acutus, Calanus propinquus, Metridia gerlachei and Rhincalanus gigas) sampled during the late austral summer in Prydz Bay, Antarctica. Our results show that diatoms, dinoflagellates and ciliates dominated copepod food sources (hypothesized to be phytoplankton and particulate organic matter) in the inner bay regions more than in the oceanic regions of Prydz Bay. Regional differences in the composition and abundance of food sources were also reflected in the fatty acid biomarkers and stable isotopic values. In the inner bay region, the total fatty acid contents of these food sources were nearly twofold higher, including greater contributions from fatty acids of dinoflagellate origin; these samples also had higher δ13C and δ15N values. Fatty acid biomarkers and stable isotopic values in copepod species roughly mirrored the spatial patterns in food sources. As found in the primary producers, the concentrations of dinoflagellate fatty acids and δ13C and δ15N values were higher in copepods from the inner bay regions. Additionally, there were inter-species differences in the fatty acids and stable isotopic values of copepods. C. acutus and C. propinquus did not exhibit significant regional differences in their total fatty acid contents. In contrast, M. gerlachei from the inner bay region had higher fatty acid values. C. acutus and C. propinquus had higher compositions of the long chain fatty acids 20:1n-9, 22:1n-9 and 22:1n-1, while docosahexaenoic acid (DHA) was higher in M. gerlachei. The δ15N values indicate that C. acutus occupies a higher trophic level than the other copepod species. Similarly, higher fatty acid ratios in M. gerlachei, including DHA/EPA(eicosapntemacnioc acid) and 18:1n-9/18:1n-7, indicate that this species feeds more opportunistically and prefers a carnivorous diet. Insights from this combined fatty acid and stable isotopic approach suggest that the dominant copepod species in Prydz Bay, Antarctica, have flexible feeding strategies that vary by food source during the late austral summer.
Schmitter, Sebastian; DelaBarre, Lance; Wu, Xiaoping; Greiser, Andreas; Wang, Dingxin; Auerbach, Edward J; Vaughan, J Thomas; Uğurbil, Kâmil; Van de Moortele, Pierre-François
2013-11-01
Higher signal to noise ratio (SNR) and improved contrast have been demonstrated at ultra-high magnetic fields (≥7 Tesla [T]) in multiple targets, often with multi-channel transmit methods to address the deleterious impact on tissue contrast due to spatial variations in B1 (+) profiles. When imaging the heart at 7T, however, respiratory and cardiac motion, as well as B0 inhomogeneity, greatly increase the methodological challenge. In this study we compare two-spoke parallel transmit (pTX) RF pulses with static B1 (+) shimming in cardiac imaging at 7T. Using a 16-channel pTX system, slice-selective two-spoke pTX pulses and static B1 (+) shimming were applied in cardiac CINE imaging. B1 (+) and B0 mapping required modified cardiac triggered sequences. Excitation homogeneity and RF energy were compared in different imaging orientations. Two-spoke pulses provide higher excitation homogeneity than B1 (+) shimming, especially in the more challenging posterior region of the heart. The peak value of channel-wise RF energy was reduced, allowing for a higher flip angle, hence increased tissue contrast. Image quality with two-spoke excitation proved to be stable throughout the entire cardiac cycle. Two-spoke pTX excitation has been successfully demonstrated in the human heart at 7T, with improved image quality and reduced RF pulse energy when compared with B1 (+) shimming. Copyright © 2013 Wiley Periodicals, Inc.
Schmidt, Barbara; Roberts, Robin S; Whyte, Robin K; Asztalos, Elizabeth V; Poets, Christian; Rabi, Yacov; Solimano, Alfonso; Nelson, Harvey
2014-10-01
To compare oxygen saturations as displayed to caregivers on offset pulse oximeters in the 2 groups of the Canadian Oxygen Trial. In 5 double-blind randomized trials of oxygen saturation targeting, displayed saturations between 88% and 92% were offset by 3% above or below the true values but returned to true values below 84% and above 96%. During the transition, displayed values remained static at 96% in the lower and at 84% in the higher target group during a 3% change in true saturations. In contrast, displayed values changed rapidly from 88% to 84% in the lower and from 92% to 96% in the higher target group during a 1% change in true saturations. We plotted the distributions of median displayed saturations on days with >12 hours of supplemental oxygen in 1075 Canadian Oxygen Trial participants to reconstruct what caregivers observed at the bedside. The oximeter masking algorithm was associated with an increase in both stability and instability of displayed saturations that occurred during the transition between offset and true displayed values at opposite ends of the 2 target ranges. Caregivers maintained saturations at lower displayed values in the higher than in the lower target group. This differential management reduced the separation between the median true saturations in the 2 groups by approximately 3.5%. The design of the oximeter masking algorithm may have contributed to the smaller-than-expected separation between true saturations in the 2 study groups of recent saturation targeting trials in extremely preterm infants. Copyright © 2014 Elsevier Inc. All rights reserved.
Anomalous Swelling in Wet-Spin Films of Divalent Calf-Thymus DNA
NASA Astrophysics Data System (ADS)
Marlowe, R. L.; Lee, S. A.; Rupprecht, A.
2004-03-01
The dimension of wet-spun oriented films of Ca- and MgDNA in the direction perpendicular to the helical axis has been measured using optical microscopy as a function of relative humidity (RH). Earlier work on monovalent DNA films found that the perpendicular dimension increases monotonically with RH. In contrast, both Ca - and MgDNA films display a 15% shrinkage in the perpendicular direction at about 93% RH and expand at higher values of RH.
Koenigkam-Santos, Marcel; Optazaite, Elzbieta; Sommer, Gregor; Safi, Seyer; Heussel, Claus Peter; Kauczor, Hans-Ulrich; Puderbach, Michael
2015-01-01
To propose a technique for evaluation of pulmonary lesions using contrast-enhanced MRI; to assess morphological patterns of enhancement and correlate quantitative analysis with histopathology. Thirty-six patients were prospectively studied. Volumetric-interpolated T1W images were obtained during consecutive breath holds after bolus triggered contrast injection. Volume coverage of first three acquisitions was limited (higher temporal resolution) and last acquisition obtained at 4th min. Two radiologists individually evaluated the patterns of enhancement. Region-of-interest-based signal intensity (SI)-time curves were created to assess quantitative parameters. Readers agreed moderately to substantially concerning lesions' enhancement pattern. SI-time curves could be created for all lesions. In comparison to benign, malignant lesions showed higher values of maximum enhancement, early peak, slope and 4th min enhancement. Early peak >15% showed 100% sensitivity to detect malignancy, maximum enhancement >40% showed 100% specificity. The proposed technique is robust, simple to perform and can be applied in clinical scenario. It allows visual evaluation of enhancement pattern/progression together with creation of SI-time curves and assessment of derived quantitative parameters. Perfusion analysis was highly sensitive to detect malignancy, in accordance to what is recommended by most recent guidelines on imaging evaluation of pulmonary lesions. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Cornil, Yann; Chandon, Pierre
2016-09-01
Research on overeating and self-regulation has associated eating pleasure with short-term visceral impulses triggered by hunger, external cues, or internal emotional urges. Drawing on research on the social and cultural dimensions of eating, we contrast this approach with what we call "Epicurean" eating pleasure, which is the enduring pleasure derived from the aesthetic appreciation of the sensory and symbolic value of the food. To contrast both approaches, we develop and test a scale measuring Epicurean eating pleasure tendencies and show that they are distinct from the tendency to experience visceral pleasure (measured using the external eating and emotional eating scales). We find that Epicurean eating pleasure is more prevalent among women than men but is independent of age, income and education. Unlike visceral eating pleasure tendencies, Epicurean eating tendencies are associated with a preference for smaller food portions and higher wellbeing, and not associated with higher BMI. Overall, we argue that the moralizing approach equating the pleasure of eating with 'low-level' visceral urges should give way to a more holistic approach which recognizes the positive role of Epicurean eating pleasure in healthy eating and wellbeing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Recurrence quantity analysis based on singular value decomposition
NASA Astrophysics Data System (ADS)
Bian, Songhan; Shang, Pengjian
2017-05-01
Recurrence plot (RP) has turned into a powerful tool in many different sciences in the last three decades. To quantify the complexity and structure of RP, recurrence quantification analysis (RQA) has been developed based on the measures of recurrence density, diagonal lines, vertical lines and horizontal lines. This paper will study the RP based on singular value decomposition which is a new perspective of RP study. Principal singular value proportion (PSVP) will be proposed as one new RQA measure and bigger PSVP means higher complexity for one system. In contrast, smaller PSVP reflects a regular and stable system. Considering the advantage of this method in detecting the complexity and periodicity of systems, several simulation and real data experiments are chosen to examine the performance of this new RQA.
Dynamic magnetic resonance imaging of the breast: Comparison of gadobutrol vs. Gd-DTPA.
Escribano, F; Sentís, M; Oliva, J C; Tortajada, L; Villajos, M; Martín, A; Ganau, S
To compare the pharmacokinetic profile of gadobutrol versus Gd-DTPA in dynamic contrast-enhanced MRI (DCE-MRI) in patients with breast cancer. Secondary objectives included comparing the safety profiles and diagnostic efficacy of the two contrast agents for detecting additional malignant lesions. This retrospective observational study included 400 patients with histologically confirmed breast cancer; 200 underwent DCE-MRI with Gd-DTPA (Magnevist®) and 200 underwent DCE-MRI with gadobutrol (Gadovist®). Pharmacokinetic parameters and signal intensity were analyzed in a region of interest placed in the area within the lesion that had greatest signal intensity in postcontrast sequences. We compared the two groups on pharmacokinetic variables (K trans , K ep , and V e ), time-signal intensity curves, and the number of additional malignant lesions detected. The relative signal intensity (enhancement) was higher with gadobutrol than with Gd-DTPA. Washout was lower with gadobutrol than with Gd-DTPA (46% vs. 58,29%, respectively; p=0,0323). Values for K trans and K ep were higher for gadobutrol (p=0,001). There were no differences in the number of histologically confirmed additional malignant lesions detected (p=0,387). Relative enhancement is greater with gadobutrol, but washout is more pronounced with Gd-DTPA. The number of additional malignant lesions detected did not differ between the two contrast agents. Both contrasts are safe. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Spatial frequency discrimination learning in normal and developmentally impaired human vision
Astle, Andrew T.; Webb, Ben S.; McGraw, Paul V.
2010-01-01
Perceptual learning effects demonstrate that the adult visual system retains neural plasticity. If perceptual learning holds any value as a treatment tool for amblyopia, trained improvements in performance must generalise. Here we investigate whether spatial frequency discrimination learning generalises within task to other spatial frequencies, and across task to contrast sensitivity. Before and after training, we measured contrast sensitivity and spatial frequency discrimination (at a range of reference frequencies 1, 2, 4, 8, 16 c/deg). During training, normal and amblyopic observers were divided into three groups. Each group trained on a spatial frequency discrimination task at one reference frequency (2, 4, or 8 c/deg). Normal and amblyopic observers who trained at lower frequencies showed a greater rate of within task learning (at their reference frequency) compared to those trained at higher frequencies. Compared to normals, amblyopic observers showed greater within task learning, at the trained reference frequency. Normal and amblyopic observers showed asymmetrical transfer of learning from high to low spatial frequencies. Both normal and amblyopic subjects showed transfer to contrast sensitivity. The direction of transfer for contrast sensitivity measurements was from the trained spatial frequency to higher frequencies, with the bandwidth and magnitude of transfer greater in the amblyopic observers compared to normals. The findings provide further support for the therapeutic efficacy of this approach and establish general principles that may help develop more effective protocols for the treatment of developmental visual deficits. PMID:20832416
Ultrasound contrast agent imaging: Real-time imaging of the superharmonics
NASA Astrophysics Data System (ADS)
Peruzzini, D.; Viti, J.; Tortoli, P.; Verweij, M. D.; de Jong, N.; Vos, H. J.
2015-10-01
Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. "superharmonic" imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which `signal' denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.
Fundamental Study of Three-dimensional Fast Spin-echo Imaging with Spoiled Equilibrium Pulse.
Ogawa, Masashi; Kaji, Naoto; Tsuchihashi, Toshio
2017-01-01
Three-dimensional fast spin-echo (3D FSE) imaging with variable refocusing flip angle has been recently applied to pre- or post-enhanced T 1 -weighted imaging. To reduce the acquisition time, this sequence requires higher echo train length (ETL), which potentially causes decreased T 1 contrast. Spoiled equilibrium (SpE) pulse consists of a resonant +90° radiofrequency (RF) pulse and is applied at the end of the echo train. This +90° RF pulse brings residual transverse magnetization to the negative longitudinal axis, which makes it possible to increase T 1 contrast. The purpose of our present study was to examine factors that influence the effect of spoiled equilibrium pulse and the relationship between T 1 contrast improvement and imaging parameters and to understand the characteristics of spoiled equilibrium pulse. Phantom studies were conducted using an magnetic resonance imaging (MRI) phantom made of polyvinyl alcohol gel. To evaluate the effect of spoiled equilibrium pulse with changes in repetition time (TR), ETL, and refocusing flip angle, we measured the signal-to-noise ratio and contrast-to-noise ratio (CNR). The effect of spoiled equilibrium pulse was evaluated by calculating the enhancement rate of CNR. The factors that influence the effect of spoiled equilibrium pulse are TR, ETL, and relaxation time of tissues. Spoiled equilibrium pulse is effective with increasing TR and decreasing ETL. The shorter the T 1 value, the better the spoiled equilibrium pulse functions. However, for tissues in which the T 1 value is long (>600 ms), at a TR of 600 ms, improvement in T 1 contrast by applying spoiled equilibrium pulse cannot be expected.
Jung, Seung Chai; Cho, Jeong Yeon
2011-01-01
Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154
NASA Astrophysics Data System (ADS)
Kattel, Dambaru Ballab; Yao, Tandong; Panday, Prajjwal Kumar
2018-05-01
Based on climatic data from 18 stations on the southern slopes of the eastern Himalayas in Bhutan for the period from 1996 to 2009, this paper investigates monthly characteristics of the near-surface air temperature lapse rate (TLR). The station elevations used in this study range from 300 to 2760 m a. s. l. TLRs were evaluated using a linear regression model. The monthly values of maximum TLRs were always smaller than those of the minimum TLRs, which is in contrast to results from the surrounding mountainous regions. In this study, annual patterns of TLRs were somewhat consistent, particularly in the summer; during the other seasons, patterns contrasted to results from the southeastern Tibetan Plateau (China) and were almost comparable to results from Nepal. The shallowest observed values for TLRs in summer are due to intense latent heating at the higher elevation, associated with water vapor condensation from moist convection and evapotranspiration, and decreasing sensible heating at lower elevation, due to heavier rainfall, cloud, and forest cover. When compared to summer, the steeper TLRs in the non-monsoon season are due to sensible heating at the lower elevations, corresponding to dry and clear weather seasons, as well as increasing cooling at higher elevations, particularly in winter due to snow and cloud cover. Owing to lower albedo and higher aerodynamic roughness of forested areas, the TLRs were considerably reduced in daytime because of the dissipation of sensible heat to the atmospheric boundary layer. The distinct variation in diurnal TLR range is due to the diurnal variation in net radiation associated with reduced turbulent heating in the day and increased turbulent heating in the night, in addition to the effect of moisture and cloud cover. The shallower values of TLRs in this study when compared with the surrounding mountainous regions are due to high humidity, as well as the differing elevations and local climates.
Langenauer, J; Betschart, P; Hechelhammer, L; Güsewell, S; Schmid, H P; Engeler, D S; Abt, D; Zumstein, V
2018-05-29
To evaluate the predictive value of advanced non-contrasted computed tomography (NCCT) post-processing using novel CT-calculometry (CT-CM) parameters compared to established predictors of success of shock wave lithotripsy (SWL) for urinary calculi. NCCT post-processing was retrospectively performed in 312 patients suffering from upper tract urinary calculi who were treated by SWL. Established predictors such as skin to stone distance, body mass index, stone diameter or mean stone attenuation values were assessed. Precise stone size and shape metrics, 3-D greyscale measurements and homogeneity parameters such as skewness and kurtosis, were analysed using CT-CM. Predictive values for SWL outcome were analysed using logistic regression and receiver operating characteristics (ROC) statistics. Overall success rate (stone disintegration and no re-intervention needed) of SWL was 59% (184 patients). CT-CM metrics mainly outperformed established predictors. According to ROC analyses, stone volume and surface area performed better than established stone diameter, mean 3D attenuation value was a stronger predictor than established mean attenuation value, and parameters skewness and kurtosis performed better than recently emerged variation coefficient of stone density. Moreover, prediction of SWL outcome with 80% probability to be correct would be possible in a clearly higher number of patients (up to fivefold) using CT-CM-derived parameters. Advanced NCCT post-processing by CT-CM provides novel parameters that seem to outperform established predictors of SWL response. Implementation of these parameters into clinical routine might reduce SWL failure rates.
Environments Perceived as Obesogenic Have Lower Residential Property Values
Drewnowski, Adam; Aggarwal, Anju; Rehm, Colin D.; Cohen-Cline, Hannah; Hurvitz, Philip M.; Moudon, Anne V.
2014-01-01
Background Studies have tried to link multiple aspects of the built environment with physical activity and obesity rates. Purpose To determine the relation between residential property values and multiple perceived (self-reported) measures of the obesogenic environment. Methods The Seattle Obesity Study (SOS) used a telephone survey of a representative, geographically distributed sample of 2,001 King County adults, collected in 2008–2009 and analyzed in 2012–2013. Home addresses were geocoded. Residential property values at the tax parcel level were obtained from the King County tax assessor. Mean residential property values within a 10-minute walk (833-meter buffer) were calculated for each respondent. Data on multiple perceived measures of the obesogenic environment were collected by self-report. Correlations and multivariable linear regression analyses, stratified by residential density, were used to examine the associations among perceived environmental measures, property values, and BMI. Results Perceived measures of the environment such as crime, heavy traffic, and proximity to bars, liquor stores, and fast food were all associated with lower property values. By contrast, living in neighborhoods that were perceived as safe, quiet, clean, and attractive was associated with higher property values. Higher property values were associated, in turn, with lower BMIs. The observed associations between perceived environment measures and BMI were largely attenuated after accounting for residential property values. Conclusions Perceived measures of obesogenic environments are associated with lower property values. Studies in additional locations need to explore to what extent other perceived environment measures can be reflected in residential property values. PMID:25049218
Ni, Liangping; Liu, Ying
2018-04-01
The present study aimed to assess early-stage nasopharyngeal carcinoma (NPC) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) at 3.0 T. A total of 44 patients newly diagnosed with NPC were included in the present study. All patients underwent MR examination at 3.0 T using DCE-MRI and DWI. The volume transfer constant ( K trans ), flux rate constant between extravascular extracellular space and plasma ( K ep ), the volume of extravascular extracellular space per unit volume of tissue ( V e ) and the apparent diffusion coefficient (ADC) of tumours were investigated. Furthermore, the correlation between clinical stages and ADC value and K trans were analysed. The diagnostic accuracy of K trans and ADC were estimated using receiver operating characteristic curves. NPC stage correlated positively with K trans and negatively with ADC values. Additionally, tumour K trans negatively correlated with ADC value. The sensitivity and accuracy of combined K trans and ADC in distinguishing between stage II and stage III and stage III and IV were higher than the values of either measurement used separately. The present study suggested that K trans and ADC derived from DCE-MRI and DWI may be useful to detect stage early NPC accurately. K trans and ADC in combination were superior than either alone.
Park, So-Yeon; Kim, Il Han; Ye, Sung-Joon; Carlson, Joel; Park, Jong Min
2014-11-01
Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman's rank correlation coefficients (rs) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MISPORT) were calculated, and their correlations were analyzed in the same way. There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The rs values of contrast to the global gamma passing rates with criteria of 2%/2 mm, 2%/1 mm, and 1%/2 mm were 0.536, 0.473, and 0.718, respectively. The respective values for variance were 0.551, 0.481, and 0.688. In the case of local gamma passing rates, the rs values of contrast were 0.547, 0.578, and 0.620, respectively, and those of variance were 0.519, 0.527, and 0.569. All of the rs values in those cases were statistically significant (p < 0.003). In the cases of global and local gamma passing rates, MISPORT showed the highest correlations among the conventional modulation indices. For global passing rates, rs values of MISPORT were -0.420, -0.330, and -0.632, respectively, and those for local passing rates were -0.455, -0.490 and -0.502. The values of rs of contrast, variance, and MISPORT with the MLC errors were -0.863, -0.828, and 0.795, respectively, all with statistical significances (p < 0.001). The correlations with statistical significances between variance and dose-volumetric differences were observed more frequently than the others. The contrast (d = 1) and variance (d = 1) calculated from fluence maps of VMAT plans showed considerable correlations with the plan deliverability, indicating their potential use as indicators for assessing the degree of modulation of VMAT plans. Both contrast and variance consistently showed better performance than the conventional modulation indices for VMAT.
Muto, Mario; Frauenfelder, Giulia; Senese, Rossana; Zeccolini, Fabio; Schena, Emiliano; Giurazza, Francesco; Jäger, Hans Rolf
2018-07-01
Distinction between treatment-related changes and tumour recurrence in patients who have received radiation treatment for brain metastases can be difficult on conventional MRI. In this study, we investigated the ability of dynamic susceptibility contrast (DSC) perfusion in differentiating necrotic changes from pathological angiogenesis and compared measurements of relative cerebral blood volume (rCBV), relative cerebral blood flow (rCBF) and K2, using a dedicated software. Twenty-nine patients with secondary brain tumors were included in this retrospective study and underwent DSC perfusion MRI with a 3-month follow-up imaging after chemo- or radiation-therapy. Region-of-interests were drawn around the contrast enhancing lesions and measurements of rCBV, rCBF and K2 were performed in all patients. Based on subsequent histological examination or clinico-radiological follow-up, the cohort was divided in two groups: recurrent disease and stable disease. Differences between the two groups were analyzed using the Student's t test. Sensitivity, specificity and diagnostic accuracy of rCBV measurements were analyzed considering three different cut-off values. Between patients with and without disease, only rCBV and rCBF values were significant (p < 0.05). The only cut-off value giving the best diagnostic accuracy of 100% was rCBV = 2.1 (sensitivity = 100%; specificity = 100%). Patients with tumor recurrence showed a higher mean value of rCBV (mean = 4.28, standard deviation = 2.09) than patients with necrotic-related changes (mean = 0.77, standard deviation = 0.44). DSC-MRI appears a clinically useful method to differentiate between tumor recurrence, tumor necrosis and pseudoprogression in patients treated for cerebral metastases. Relative CBV using a cut-off value of 2.1 proved to be the most accurate and reliable parameter.
Jansen, Erica C; Miller, Alison L; Lumeng, Julie C; Kaciroti, Niko; Brophy Herb, Holly E; Horodynski, Mildred A; Contreras, Dawn; Peterson, Karen E
2017-10-03
High intake of added sugar and sodium is a public health concern for preschool-aged children living in the US. Externalizing behavior may predict higher consumption of added sugar and/or sodium; however, previous studies have mostly been cross-sectional. The aim was to evaluate whether externalizing behavior is prospectively related to added sugar and intake in a sex-specific manner among preschoolers. This was a secondary analysis of 524 preschool children (48% male) from Michigan who participated in an obesity prevention trial that occurred during one school year from 2011 to 2015. Teacher-assessed externalizing behaviors and three 24-h dietary recalls were completed at baseline and follow-up. We used linear mixed effects regression to evaluate the association between externalizing behavior at baseline and added sugar (% of total Calories) and sodium intake (mg/1000 Calories) at follow-up. In adjusted analysis, we included baseline income-to-needs ratio, child race/ethnicity, and baseline overweight status. All models were adjusted for total energy intake and accounted for clustering by classroom. Baseline externalizing behavior was positively associated with added sugar intake at follow-up among boys; after adjustment for confounders, every 5 points lower externalizing T-score (corresponding to higher externalizing behavior) was associated with a 0.6 higher percentage of added sugar per total Calories (95% CI 0.2 to 1.1; P value = 0.004). In contrast, girls with higher levels of externalizing behavior had lower consumption of added sugars; after confounder adjustment, every 5 points lower externalizing T-score was related to 0.6 lower percentage intake (95% CI -1.0 to -0.1; P value = 0.01). Baseline externalizing behavior was inversely associated with sodium intake at follow-up among boys. After potential confounder adjustment, for every 5 points lower externalizing behavior T-score, there was a 22 mg/1000 Cal lower sodium intake (95% CI -45 to 1; P value = 0.06). In contrast, after adjustment for confounders, every 5 points lower externalizing T-score among girls was related to 24 mg/1000 Cal higher sodium intake (95% CI 1 to 46; P value = 0.04). Externalizing behavior among preschool-aged children was prospectively related to added sugar and sodium intake in a sex-dependent manner. NCT01398358 Registered 19 July 2011.
NASA Technical Reports Server (NTRS)
Knoll, A. H.; Kaufman, A. J.; Semikhatov, M. A.
1995-01-01
Thick carbonate-dominated successions in northwestern Siberia document secular variations in the C-isotopic composition of seawater through Mesoproterozoic and early Neoproterozoic (Early to early Late Riphean) time. Mesoproterozoic dolomites of the Billyakh Group, Anabar Massif, have delta 13C values that fall between 0 and -1.9 permil versus PDB, with values in the upper part of the succession (Yusmastakh Formation) consistently higher than those of the lower (Ust'-Il'ya and Kotuikan formations). Consistent with available biostratigraphic and radiometric data, delta 13C values for Billyakh carbonates compare closely with those characterizing early Mesoproterozoic carbonates (about 1600-1200 Ma) worldwide. In contrast, late Mesoproterozoic to early Neoproterozoic limestones and dolomites in the Turukhansk Uplift exhibit moderate levels of secular variation. Only the lowermost carbonates in the Turukhansk succession (Linok Formation) have delta 13C values that approximate Billyakh values. Higher in the Turukhansk succession, delta 13C values vary from -2.7 to +4.6 permil (with outliers as low as -5.0 permil interpreted as diagentically altered). Again, consistent with paleontological and radiometric data, these values compare well with isotopic values from 1200 to 850 Ma successions elsewhere. Five sections measured in different parts of the Turukhansk basin show nearly identical patterns of variation, confirming that carbonate delta 13C correlates primarily with time and not facies. The Siberian sections illustrate the potential of integrated biostratigraphic and chemostratigraphic data in the intra- and interbasinal correlation of Mesoproterozoic and early Neoproterozoic rocks.
Lisowska, A; Knapp, M; Tycinska, A; Sawicki, R; Kralisz, P; Lisowski, P; Sobkowicz, B; Musial, W I
2014-02-01
Contrast-enhanced ultrasound imaging of the carotid arteries (CECU) permits direct, real-time visualization of neovascularization in atherosclerotic plaques and is a confirmed predictor of unstable atheromatous lesions. The aim of the study was the assessment of a new, automatically measured index of intensity in quantitative estimation of the contrast flow through the carotid plaque (till now assessed only visually). Forty-four patients (mean age 70.4±11.4) with ultrasound diagnosed significant stenosis of internal carotid artery (ICA), after cerebrovascular or cardiovascular events, qualified for carotid artery stenting (CAS) were examined. The carotid ultrasound examinations with contrast agent Sonovue were performed. Visually in 22 patients (50%) contrast flow through the atherosclerotic plaques was found. In 17 patients (38.6%) massive, calcified atherosclerotic plaques were present. Patients with preserved contrast flow through the plaque more frequently had a history of cerebral stroke (P=0.04). Massive calcifications of atherosclerotic plaques correlated with a previous MI (P=0.03) and the degree of advancement of coronary artery disease (P=0.04), but not with a previous cerebral stroke. Contrast flow through the atherosclerotic plaque positively correlated with values of the index of intensity (r=0.69, P<0.00001). In patients with preserved contrast flow the mean value of the index of intensity was 22.24±3.55 dB as compared with 12.37±7.67 dB - a value present in patients without preserved contrast flow. No significant relation for the degree of calcifications and the value of the index of intensity was found. The assessment of the index of intensity is a novel, simple and automatic method to estimate the degree of contrast flow through the carotid plaque. The values of the index of intensity correlate with the contrast flow through the atherosclerotic plaque, but not with its calcification.
A study of quantification of aortic compliance in mice using radial acquisition phase contrast MRI
NASA Astrophysics Data System (ADS)
Zhao, Xuandong
Spatiotemporal changes in blood flow velocity measured using Phase contrast Magnetic Resonance Imaging (MRI) can be used to quantify Pulse Wave Velocity (PWV) and Wall Shear Stress (WSS), well known indices of vessel compliance. A study was conducted to measure the PWV in the aortic arch in young healthy children using conventional phase contrast MRI and a post processing algorithm that automatically track the peak velocity in phase contrast images. It is shown that the PWV calculated using peak velocity-time data has less variability compared to that using mean velocity and flow. Conventional MR data acquisition techniques lack both the spatial and temporal resolution needed to accurately calculate PWV and WSS in in vivo studies using transgenic animal models of arterial diseases. Radial k-space acquisition can improve both spatial and temporal resolution. A major part of this thesis was devoted to developing technology for Radial Phase Contrast Magnetic Resonance (RPCMR) cine imaging on a 7 Tesla Animal scanner. A pulse sequence with asymmetric radial k-space acquisition was designed and implemented. Software developed to reconstruct the RPCMR images include gridding, density compensation and centering of k-Space that corrects the image ghosting introduced by hardware response time. Image processing software was developed to automatically segment the vessel lumen and correct for phase offset due to eddy currents. Finally, in vivo and ex vivo aortic compliance measurements were conducted in a well-established mouse model for atherosclerosis: Apolipoprotein E-knockout (ApoE-KO). Using RPCMR technique, a significantly higher PWV value as well as a higher average WSS was detected among 9 months old ApoE-KO mice compare to in wild type mice. A follow up ex-vivo test of tissue elasticity confirmed the impaired distensibility of aortic arteries among ApoE-KO mice.
Risk-dependent reward value signal in human prefrontal cortex
Tobler, Philippe N.; Christopoulos, George I.; O'Doherty, John P.; Dolan, Raymond J.; Schultz, Wolfram
2009-01-01
When making choices under uncertainty, people usually consider both the expected value and risk of each option, and choose the one with the higher utility. Expected value increases the expected utility of an option for all individuals. Risk increases the utility of an option for risk-seeking individuals, but decreases it for risk averse individuals. In 2 separate experiments, one involving imperative (no-choice), the other choice situations, we investigated how predicted risk and expected value aggregate into a common reward signal in the human brain. Blood oxygen level dependent responses in lateral regions of the prefrontal cortex increased monotonically with increasing reward value in the absence of risk in both experiments. Risk enhanced these responses in risk-seeking participants, but reduced them in risk-averse participants. The aggregate value and risk responses in lateral prefrontal cortex contrasted with pure value signals independent of risk in the striatum. These results demonstrate an aggregate risk and value signal in the prefrontal cortex that would be compatible with basic assumptions underlying the mean-variance approach to utility. PMID:19369207
Effect of signal intensity and camera quantization on laser speckle contrast analysis
Song, Lipei; Elson, Daniel S.
2012-01-01
Laser speckle contrast analysis (LASCA) is limited to being a qualitative method for the measurement of blood flow and tissue perfusion as it is sensitive to the measurement configuration. The signal intensity is one of the parameters that can affect the contrast values due to the quantization of the signals by the camera and analog-to-digital converter (ADC). In this paper we deduce the theoretical relationship between signal intensity and contrast values based on the probability density function (PDF) of the speckle pattern and simplify it to a rational function. A simple method to correct this contrast error is suggested. The experimental results demonstrate that this relationship can effectively compensate the bias in contrast values induced by the quantized signal intensity and correct for bias induced by signal intensity variations across the field of view. PMID:23304650
A comparison between temporal and subband minimum variance adaptive beamforming
NASA Astrophysics Data System (ADS)
Diamantis, Konstantinos; Voxen, Iben H.; Greenaway, Alan H.; Anderson, Tom; Jensen, Jørgen A.; Sboros, Vassilis
2014-03-01
This paper compares the performance between temporal and subband Minimum Variance (MV) beamformers for medical ultrasound imaging. Both adaptive methods provide an optimized set of apodization weights but are implemented in the time and frequency domains respectively. Their performance is evaluated with simulated synthetic aperture data obtained from Field II and is quantified by the Full-Width-Half-Maximum (FWHM), the Peak-Side-Lobe level (PSL) and the contrast level. From a point phantom, a full sequence of 128 emissions with one transducer element transmitting and all 128 elements receiving each time, provides a FWHM of 0.03 mm (0.14λ) for both implementations at a depth of 40 mm. This value is more than 20 times lower than the one achieved by conventional beamforming. The corresponding values of PSL are -58 dB and -63 dB for time and frequency domain MV beamformers, while a value no lower than -50 dB can be obtained from either Boxcar or Hanning weights. Interestingly, a single emission with central element #64 as the transmitting aperture provides results comparable to the full sequence. The values of FWHM are 0.04 mm and 0.03 mm and those of PSL are -42 dB and -46 dB for temporal and subband approaches. From a cyst phantom and for 128 emissions, the contrast level is calculated at -54 dB and -63 dB respectively at the same depth, with the initial shape of the cyst being preserved in contrast to conventional beamforming. The difference between the two adaptive beamformers is less significant in the case of a single emission, with the contrast level being estimated at -42 dB for the time domain and -43 dB for the frequency domain implementation. For the estimation of a single MV weight of a low resolution image formed by a single emission, 0.44 * 109 calculations per second are required for the temporal approach. The same numbers for the subband approach are 0.62 * 109 for the point and 1.33 * 109 for the cyst phantom. The comparison demonstrates similar resolution but slightly lower side-lobes and higher contrast for the subband approach at the expense of increased computation time.
Todokoro, Ayako; Tanaka, Saori C; Kawakubo, Yuki; Yahata, Noriaki; Ishii-Takahashi, Ayaka; Nishimura, Yukika; Kano, Yukiko; Ohtake, Fumio; Kasai, Kiyoto
2018-04-24
Impulsivity, which significantly affects social adaptation, is an important target behavioral characteristic in interventions for attention-deficit hyperactivity disorder (ADHD). Typically, people are willing to wait longer to acquire greater rewards. Impulsivity in ADHD may be associated with brain dysfunction in decision-making involving waiting behavior under such situations. We tested the hypothesis that brain circuitry during a period of waiting (i.e., prior to the acquisition of reward) is altered in adults with ADHD. The participants included 14 medication-free adults with ADHD and 16 healthy controls matched for age, sex, IQ, and handedness. The behavioral task had participants choose between a delayed, larger monetary reward and an immediate, smaller monetary reward, where the reward waiting time actually occurred during functional magnetic resonance imaging measurement. We tested for group differences in the contrast values of blood-oxygen-level dependent signals associated with the length of waiting time, calculated using the parametric modulation method. While the two groups did not differ in the time discounting rate, the delay-sensitive contrast values were significantly lower in the caudate and visual cortex in individuals with ADHD. The higher impulsivity scores were significantly associated with lower delay-sensitive contrast values in the caudate and visual cortex. These results suggest that deficient neural activity affects decision-making involving reward waiting time during intertemporal choice tasks, and provide an explanation for the basis of impulsivity in adult ADHD. © 2018 The Author. Psychiatry and Clinical Neurosciences © 2018 Japanese Society of Psychiatry and Neurology.
Strong electromagnetic pulses generated in high-intensity laser-matter interactions
NASA Astrophysics Data System (ADS)
Rączka, P.; Dubois, J.-L.; Hulin, S.; Rosiński, M.; Zaraś-Szydłowska, A.; Badziak, J.
2018-01-01
Results are reported of an experiment performed at the Eclipse laser facility in CELIA, Bordeaux, on the generation of strong electromagnetic pulses. Measurements were performed of the target neutralization current, the total target charge and the tangential component of the magnetic field for the laser energies ranging from 45 mJ to 92 mJ with the pulse duration approximately 40 fs, and for the pulse durations ranging from 39 fs to 1000 fs, with the laser energy approximately 90 mJ. It was found that the values obtained for thick (mm scale) Cu targets are visibly higher than values reported in previous experiments, which is argued to be a manifestation of a strong dependence of the target electric polarization process on the laser contrast and hence on the amount of preplasma. It was also found that values obtained for thin (μm scale) Al foils were visibly higher than values for thick Cu targets, especially for pulse durations longer than 100 fs. The correlations between the total target charge versus the maximum value of the target neutralization current, and the maximum value of the tangential component of the magnetic field versus the total target charge were analysed. They were found to be in very good agreement with correlations seen in data from previous experiments, which provides a good consistency check on our experimental procedures.
Influence of impression technique and material on the accuracy of multiple implant impressions.
Wöstmann, Bernd; Rehmann, Peter; Balkenhol, Markus
2008-01-01
This study aimed to analyze the influence of impression technique (pick-up versus reposition) and material on the accuracy of the working cast. Sixty impressions were made with 3 materials from a master cast with 4 XiVE implants. The changes in the implant axis direction, rotation, and 3-dimensional shift were assessed. The pick-up technique showed significantly (P < .05, U test) lower values for axis direction and 3D shift but higher values for rotation than the reposition technique. The differences between the materials were not significant (P > .05, H test). It can be concluded that the impression technique-in contrast to the impression material-has a significant influence on transfer accuracy.
Miyake, Yuka; Ishikawa, Syungo; Kimura, Yu; Son, Aoi; Imai, Hirohiko; Matsuda, Tetsuya; Yamada, Hisatsugu; Toshimitsu, Akio; Kondo, Teruyuki
2015-12-18
Recently, we developed novel chiral dendrimer-triamine-coordinated Gd-MRI contrast agents (Gd-MRI CAs), which showed longitudinal relaxivity (r₁) values about four times higher than that of clinically used Gd-DTPA (Magnevist(®), Bayer). In our continuing study of pharmacokinetic differences derived from both the chirality and generation of Gd-MRI CAs, we found that the ability of chiral dendrimer Gd-MRI CAs to circulate within the body can be directly evaluated by in vitro MRI (7 T). In this study, the association constants (K(a)) of chiral dendrimer Gd-MRI CAs to bovine serum albumin (BSA), measured and calculated with a quartz crystal microbalance (QCM) in vitro, were found to be an extremely easy means for evaluating the body-circulation ability of chiral dendrimer Gd-MRI CAs. The K(a) values of S-isomeric dendrimer Gd-MRI CAs were generally greater than those of R-isomeric dendrimer Gd-MRI CAs, which is consistent with the results of our previous MRI study in vivo.
Miyake, Yuka; Ishikawa, Syungo; Kimura, Yu; Son, Aoi; Imai, Hirohiko; Matsuda, Tetsuya; Yamada, Hisatsugu; Toshimitsu, Akio; Kondo, Teruyuki
2015-01-01
Recently, we developed novel chiral dendrimer-triamine-coordinated Gd-MRI contrast agents (Gd-MRI CAs), which showed longitudinal relaxivity (r1) values about four times higher than that of clinically used Gd-DTPA (Magnevist®, Bayer). In our continuing study of pharmacokinetic differences derived from both the chirality and generation of Gd-MRI CAs, we found that the ability of chiral dendrimer Gd-MRI CAs to circulate within the body can be directly evaluated by in vitro MRI (7 T). In this study, the association constants (Ka) of chiral dendrimer Gd-MRI CAs to bovine serum albumin (BSA), measured and calculated with a quartz crystal microbalance (QCM) in vitro, were found to be an extremely easy means for evaluating the body-circulation ability of chiral dendrimer Gd-MRI CAs. The Ka values of S-isomeric dendrimer Gd-MRI CAs were generally greater than those of R-isomeric dendrimer Gd-MRI CAs, which is consistent with the results of our previous MRI study in vivo. PMID:26694418
Ilan, Ezgi; Sandström, Mattias; Velikyan, Irina; Sundin, Anders; Eriksson, Barbro; Lubberink, Mark
2017-05-01
68 Ga-DOTATOC and 68 Ga-DOTATATE are radiolabeled somatostatin analogs used for the diagnosis of somatostatin receptor-expressing neuroendocrine tumors (NETs), and SUV measurements are suggested for treatment monitoring. However, changes in net influx rate ( K i ) may better reflect treatment effects than those of the SUV, and accordingly there is a need to compute parametric images showing K i at the voxel level. The aim of this study was to evaluate parametric methods for computation of parametric K i images by comparison to volume of interest (VOI)-based methods and to assess image contrast in terms of tumor-to-liver ratio. Methods: Ten patients with metastatic NETs underwent a 45-min dynamic PET examination followed by whole-body PET/CT at 1 h after injection of 68 Ga-DOTATOC and 68 Ga-DOTATATE on consecutive days. Parametric K i images were computed using a basis function method (BFM) implementation of the 2-tissue-irreversible-compartment model and the Patlak method using a descending aorta image-derived input function, and mean tumor K i values were determined for 50% isocontour VOIs and compared with K i values based on nonlinear regression (NLR) of the whole-VOI time-activity curve. A subsample of healthy liver was delineated in the whole-body and K i images, and tumor-to-liver ratios were calculated to evaluate image contrast. Correlation ( R 2 ) and agreement between VOI-based and parametric K i values were assessed using regression and Bland-Altman analysis. Results: The R 2 between NLR-based and parametric image-based (BFM) tumor K i values was 0.98 (slope, 0.81) and 0.97 (slope, 0.88) for 68 Ga-DOTATOC and 68 Ga-DOTATATE, respectively. For Patlak analysis, the R 2 between NLR-based and parametric-based (Patlak) tumor K i was 0.95 (slope, 0.71) and 0.92 (slope, 0.74) for 68 Ga-DOTATOC and 68 Ga-DOTATATE, respectively. There was no bias between NLR and parametric-based K i values. Tumor-to-liver contrast was 1.6 and 2.0 times higher in the parametric BFM K i images and 2.3 and 3.0 times in the Patlak images than in the whole-body images for 68 Ga-DOTATOC and 68 Ga-DOTATATE, respectively. Conclusion: A high R 2 and agreement between NLR- and parametric-based K i values was found, showing that K i images are quantitatively accurate. In addition, tumor-to-liver contrast was superior in the parametric K i images compared with whole-body images for both 68 Ga-DOTATOC and 68 Ga DOTATATE. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Greulich, Simon; Mayr, Agnes; Kitterer, Daniel; Latus, Joerg; Henes, Joerg; Steubing, Hannah; Kaesemann, Philipp; Patrascu, Alexandru; Greiser, Andreas; Groeninger, Stefan; Braun, Niko; Alscher, M Dominik; Sechtem, Udo; Mahrholdt, Heiko
2017-01-06
Myocardial involvement in AAV patients might be silent, presenting with no or nonspecific symptoms, normal ECG, and preserved left-ventricular ejection fraction (LV-EF). Since up to 50% of deaths in these patients may be due to myocardial involvement, a reliable diagnostic tool is warranted. In contrast to LGE-CMR, which has its strengths in detecting focal inflammatory or fibrotic processes, recent mapping techniques are able to detect even subtle, diffuse inflammatory or fibrotic processes. Our study sought to investigate ANCA (antineutrophil cytoplasmic antibody) associated vasculitides (AAV) patients for myocardial involvement by a cardiovascular magnetic resonance (CMR) protocol, including late gadolinium enhancement (LGE) and mapping sequences. Thirty seven AAV patients were prospectively enrolled and underwent CMR imaging. Twenty healthy volunteers served as controls. Mean LV-EF was 64%; LGE prevalence of the AAV patients was 43%. AAV patients had higher median native T1 (988 vs. 952 ms, p < 0.001), lower post-contrast T1 (488 vs. 524 ms, p = 0.03), expanded extracellular volume (ECV) (27.5 vs. 24.5%, p < 0.001), and higher T2 (53 vs. 49 ms, p < 0.001) compared to controls, with most parameters independent of the LGE status. Native T1 and T2 in AAV patients showed the highest prevalence of abnormally increased values beyond the 95% percentile of controls. AAV patients demonstrated increased T1, ECV, and T2 values, with native T1 and T2 showing the highest prevalence of values beyond the 95% percentile of normal. Since these findings seem to be independent of LGE, mapping techniques may provide complementary information to LGE-CMR in the assessment of myocardial involvement in patients with AAV.
NASA Astrophysics Data System (ADS)
Tomaru, Hitoshi; Fehn, Udo
2015-01-01
Halogen concentrations and 129I/I ratios were determined in pore waters from the Nankai Trough subduction system, collected during IODP Expeditions 315, 316, 322, and 333 along the NanTroSEIZE transect. The transect allowed the first direct comparison of iodine results across an active subduction system, from subducting oceanic sediments to the accretionary prism, and the overlying forearc basin. In contrast to the other halogens (Cl and Br) iodine concentrations show large variations within and among the cores at all sites landward of the trough, I concentrations increase rapidly with depth and reach values several orders of magnitude higher than those in seawater, but are only slightly higher than seawater values at the seaward sites. Methane concentrations follow a similar pattern. Host sediments of the fluids are younger than 7 Ma in all the cores, but the ages of iodine in pore waters at the landward sites reach values beyond 30 Ma. In contrast, iodine seaward of the trough is in isotopic equilibrium with the host sediments, resulting in very similar iodine and sediment ages. The distribution of iodine concentrations and ages indicates that iodine at the landward sites has been transported there in aqueous fluids, probably together with methane, from old formations in the upper plate. The specific fluid pathways potentially were influenced by features such as the megasplay fault in the prism or the décollement. The results demonstrate large-scale transport of fluids carrying iodine and other compounds such as methane from old layers in the upper plate to surface locations landward of the Nankai Trough, while separate, but only local hydrologic processes occur in the marine sediments moving toward the trough.
Digital mammography--DQE versus optimized image quality in clinical environment: an on site study
NASA Astrophysics Data System (ADS)
Oberhofer, Nadia; Fracchetti, Alessandro; Springeth, Margareth; Moroder, Ehrenfried
2010-04-01
The intrinsic quality of the detection system of 7 different digital mammography units (5 direct radiography DR; 2 computed radiography CR), expressed by DQE, has been compared with their image quality/dose performances in clinical use. DQE measurements followed IEC 62220-1-2 using a tungsten test object for MTF determination. For image quality assessment two different methods have been applied: 1) measurement of contrast to noise ratio (CNR) according to the European guidelines and 2) contrast-detail (CD) evaluation. The latter was carried out with the phantom CDMAM ver. 3.4 and the commercial software CDMAM Analyser ver. 1.1 (both Artinis) for automated image analysis. The overall image quality index IQFinv proposed by the software has been validated. Correspondence between the two methods has been shown figuring out a linear correlation between CNR and IQFinv. All systems were optimized with respect to image quality and average glandular dose (AGD) within the constraints of automatic exposure control (AEC). For each equipment, a good image quality level was defined by means of CD analysis, and the corresponding CNR value considered as target value. The goal was to achieve for different PMMA-phantom thicknesses constant image quality, that means the CNR target value, at minimum dose. All DR systems exhibited higher DQE and significantly better image quality compared to CR systems. Generally switching, where available, to a target/filter combination with an x-ray spectrum of higher mean energy permitted dose savings at equal image quality. However, several systems did not allow to modify the AEC in order to apply optimal radiographic technique in clinical use. The best ratio image quality/dose was achieved by a unit with a-Se detector and W anode only recently available on the market.
Multiphase contrast medium injection for optimization of computed tomographic coronary angiography.
Budoff, Matthew Jay; Shinbane, Jerold S; Child, Janis; Carson, Sivi; Chau, Alex; Liu, Stephen H; Mao, SongShou
2006-02-01
Electron beam angiography is a minimally invasive imaging technique. Adequate vascular opacification throughout the study remains a critical issue for image quality. We hypothesized that vascular image opacification and uniformity of vascular enhancement between slices can be improved using multiphase contrast medium injection protocols. We enrolled 244 consecutive patients who were randomized to three different injection protocols: single-phase contrast medium injection (Group 1), dual-phase contrast medium injection with each phase at a different injection rate (Group 2), and a three-phase injection with two phases of contrast medium injection followed by a saline injection phase (Group 3). Parameters measured were aortic opacification based on Hounsfield units and uniformity of aortic enhancement at predetermined slices (locations from top [level 1] to base [level 60]). In Group 1, contrast opacification differed across seven predetermined locations (scan levels: 1st versus 60th, P < .05), demonstrating significant nonuniformity. In Group 2, there was more uniform vascular enhancement, with no significant differences between the first 50 slices (P > .05). In Group 3, there was greater uniformity of vascular enhancement and higher mean Hounsfield units value across all 60 images, from the aortic root to the base of the heart (P < .05). The three-phase injection protocol improved vascular opacification at the base of the heart, as well as uniformity of arterial enhancement throughout the study.
Histogram analysis of ADC in brain tumor patients
NASA Astrophysics Data System (ADS)
Banerjee, Debrup; Wang, Jihong; Li, Jiang
2011-03-01
At various stage of progression, most brain tumors are not homogenous. In this presentation, we retrospectively studied the distribution of ADC values inside tumor volume during the course of tumor treatment and progression for a selective group of patients who underwent an anti-VEGF trial. Complete MRI studies were obtained for this selected group of patients including pre- and multiple follow-up, post-treatment imaging studies. In each MRI imaging study, multiple scan series were obtained as a standard protocol which includes T1, T2, T1-post contrast, FLAIR and DTI derived images (ADC, FA etc.) for each visit. All scan series (T1, T2, FLAIR, post-contrast T1) were registered to the corresponding DTI scan at patient's first visit. Conventionally, hyper-intensity regions on T1-post contrast images are believed to represent the core tumor region while regions highlighted by FLAIR may overestimate tumor size. Thus we annotated tumor regions on the T1-post contrast scans and ADC intensity values for pixels were extracted inside tumor regions as defined on T1-post scans. We fit a mixture Gaussian (MG) model for the extracted pixels using the Expectation-Maximization (EM) algorithm, which produced a set of parameters (mean, various and mixture coefficients) for the MG model. This procedure was performed for each visits resulting in a series of GM parameters. We studied the parameters fitted for ADC and see if they can be used as indicators for tumor progression. Additionally, we studied the ADC characteristics in the peri-tumoral region as identified by hyper-intensity on FLAIR scans. The results show that ADC histogram analysis of the tumor region supports the two compartment model that suggests the low ADC value subregion corresponding to densely packed cancer cell while the higher ADC value region corresponding to a mixture of viable and necrotic cells with superimposed edema. Careful studies of the composition and relative volume of the two compartments in tumor region may provide some insights in the early assessment of tumor response to therapy for recurrence brain cancer patients.
Bae, Min Sun; Jahng, Geon-Ho; Ryu, Chang Woo; Kim, Eui Jong; Choi, Woo Suk; Yang, Dal Mo
2009-12-01
The aim of this study was to investigate whether indices of diffusion tensor MRI (DT-MRI) are altered after contrast medium injection in patients with brain tumors. DT-MRIs at a 3-T unit before and 6 min after gadolinium-diethylenetriamine penta-acetic acid injection were obtained in nine patients (five women, four men) with histologically confirmed brain tumors (four metastases, one glioblastoma multiforme, three meningiomas, and one lymphoma). Fractional anisotropy (FA), trace and mean raw DT-MRI data without (DT_b0, b value = 0 s/mm(2)) and with (DT_b800, b value = 800 s/mm(2)) diffusion-encoded gradients were calculated. Regions of interest (ROIs) were placed in the tumor, peritumoral edema, and normal-appearing symmetric contralateral brain tissue for each patient. The Kruskal-Wallis rank sum test was used to determine the effects of contrast medium and ROI for all of the maps, and the Wilcoxon signed-rank test was performed for either paired t test between pre- and post-contrast values of DTI indices for the ROIs or the post hoc test. Statistically significant differences between pre-contrast and post-contrast DT-MRI are shown in the trace value of the peritumoral edema area (p = 0.0195) and the FA value of the tumor area (p = 0.0273). Trace and FA values of the other areas show no statistically significant differences between pre- and post-contrast (p > 0.05). In addition, we find a significant ROI effect for both FA (chi (2) = 26.514, df = 2, p = 0.0001) and trace (chi (2) = 21.218, df = 2, p = 0.0001). DT-MRI obtained after contrast medium injection of 6 min results in significant changes in diffusion isotropic and anisotropic values. Therefore, clinical applications of DT-MRI after administrating a contrast medium require caution in interpretation.
Luo, Furong; Bao, Xuan; Qin, Yingyan; Hou, Min; Wu, Mingxing
2018-06-01
To evaluate the long-term effect of glistenings and surface light scattering of intraocular lenses (IOLs) on visual and optical performance after cataract surgery. Pseudophakic eyes that underwent standard phacoemulsification and two types of hydrophobic acrylic spherical IOL implantation without complications for at least 5 years were included in this retrospective study. Participants were divided into the glistenings, surface light scattering, and control groups according to the current condition of the IOLs. Then participants received a follow-up examination including uncorrected and corrected distance visual acuity (UDVA and CDVA), contrast sensitivity, straylight, and intraocular higher order aberrations, as well as point spread function (PSF) and modulation transfer function (MTF). A total of 140 eyes were included in the study. UDVA, CDVA, and glare sensitivity were not significantly different among the three groups (P > .05). However, compared with the control group, the IOLs of the glistenings and surface light scattering groups were associated with significantly lower contrast sensitivity under no glare conditions. Furthermore, eye with glistenings exhibited the highest straylight value (P < .05), whereas no difference was found between the surface light scattering and control groups. In contrast to the control group, the spherical aberration increased and the mean values of PSF and MTF decreased in the glistenings and surface light scattering groups. Both glistenings and surface light scattering tend to impair subjective visual performance, such as contrast sensitivity, and potentially affect objective optical quality, including straylight, spherical aberration, PSF, and MTF. [J Refract Surg. 2018;34(6):372-378.]. Copyright 2018, SLACK Incorporated.
Meng, Wu; Ying, Wang; Qichao, Zheng; Ping, Li; Jie, Tang
2017-01-01
Objectives: To increase accuracy of the detection and differential diagnosis of the early epithelial ovarian cancer (EOC) with transvaginal contrast-enhanced ultrasonography (TVCEUS) combining serum human epididymisprotein 4 (HE4), and resistance index (RI). Methods: This retrospectively case-control study of 230 patients with ovarian tumors were reviewed at the Department of Gynecology and Obstetrics, Zhongnan Hospital, Wuhan University, Wuhan, China between June 2008 and September 2015. Before the operation of 110 cases with EOC (Group A) and 120 cases of patients with benign ovarian tumor (Group B), we observe and calculate both Groups’ tumor vascular contrast-enhanced ultrasonography morphology scores (U), time-intensity curve (TIC) of contrast-enhanced ultrasonography, HE4, and RI. Results were compared with the histopathological analysis results. Results: The ultrasonography morphology scores, peak intensity (PI) enhancement rate (ER) with the parameters of the TIC and HE4 are higher in Group A compared with patients in Group B and the RI was lower than Group B. The detection rates for all indexes in the benign and malignant groups and their comparisons to the histopathological results were determined. The detection rate differences for HE4 (p=0.001), RI (p=0.001), U (p=0.001), PI (p=0.001), and ER (p=0.001) were all statistically significant (p<0.05). Conclusion: The high clinical value through combined TVCEUS, HE4, and RI detection can increase the sensitivity of the diagnosis and differential diagnosis of the early EOC. PMID:28578437
Favazza, Christopher P; Ferrero, Andrea; Yu, Lifeng; Leng, Shuai; McMillan, Kyle L; McCollough, Cynthia H
2017-07-01
The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.
SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gauntt, D
2015-06-15
Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results ofmore » measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.« less
Toelly, Andrea; Bardach, Constanze; Weber, Michael; Gong, Rui; Lai, Yanbo; Wang, Pei; Guo, Yulin; Kirschke, Jan; Baum, Thomas; Gruber, Michael
2017-06-01
Aim To evaluate the differences in phantom-less bone mineral density (BMD) measurements in contrast-enhanced routine MDCT scans at different contrast phases, and to develop an algorithm for calculating a reliable BMD value. Materials and Methods 112 postmenopausal women from the age of 40 to 77 years (mean age: 57.31 years; SD 9.61) who underwent a clinically indicated MDCT scan, consisting of an unenhanced, an arterial, and a venous phase, were included. A retrospective analysis of the BMD values of the Th12 to L4 vertebrae in each phase was performed using a commercially available phantom-less measurement tool. Results The mean BMD value in the unenhanced MDCT scans was 79.76 mg/cm³ (SD 31.20), in the arterial phase it was 85.09 mg/cm³ (SD 31.61), and in the venous phase it was 86.18 mg/cm³ (SD 31.30). A significant difference (p < 0.001) was found between BMD values on unenhanced and contrast-enhanced MDCT scans. There was no significant difference between BMD values in the arterial and venous phases (p = 0.228). The following conversion formulas were calculated using linear regression: unenhanced BMD = -2.287 + 0.964 * [arterial BMD value] and -4.517 + 0.978 * [venous BMD value]. The intrarater agreement of BMD measurements was calculated with an intraclass correlation (ICC) of 0.984 and the interobserver reliability was calculated with an ICC of 0.991. Conclusion Phantom-less BMD measurements in contrast-enhanced MDCT scans result in increased mean BMD values, but, with the formulas applied in our study, a reliable BMD value can be calculated. However, the mean BMD values did not differ significantly between the arterial and venous phases. Key points · BMD can be assessed on routine CT scans using a phantom-less tool.. · i. v. contrast agent significantly elevates BMD values measured on routine CT scans.. · BMD values measured in the arterial and venous phase did not differ significantly.. · Conversion formulas were defined for the calculation of a reliable BMD.. · The phantom-less tool showed good reliability and is a promising method.. Citation Format · Toelly A, Bardach C, Weber M et al. Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool. Fortschr Röntgenstr 2017; 189: 537 - 543. © Georg Thieme Verlag KG Stuttgart · New York.
[Quantitative evaluation of Gd-EOB-DTPA uptake in phantom study for liver MRI].
Hayashi, Norio; Miyati, Tosiaki; Koda, Wataru; Suzuki, Masayuki; Sanada, Shigeru; Ohno, Naoki; Hamaguchi, Takashi; Matsuura, Yukihiro; Kawahara, Kazuhiro; Yamamoto, Tomoyuki; Matsui, Osamu
2010-05-20
Gd-EOB-DTPA is a new liver specific MRI contrast media. In the hepatobiliary phase, contrast media is trapped in normal liver tissue, a normal liver shows high intensity, tumor/liver contrast becomes high, and diagnostic ability improves. In order to indicate the degree of uptake of the contrast media, the enhancement ratio (ER) is calculated. The ER is obtained by calculating (signal intensity (SI) after injection-SI before injection) / SI before injection. However, because there is no linearity between contrast media concentration and SI, ER is not correctly estimated by this method. We discuss a method of measuring ER based on SI and T(1) values using the phantom. We used a column phantom, with an internal diameter of 3 cm, that was filled with Gd-EOB-DTPA diluted solution. Moreover, measurement of the T(1) value by the IR method was also performed. The ER measuring method of this technique consists of the following three components: 1) Measurement of ER based on differences in 1/T(1) values using the variable flip angle (FA) method, 2) Measurement of differences in SI, and 3) Measurement of differences in 1/T(1) values using the IR method. ER values calculated by these three methods were compared. In measurement made using the variable FA method and the IR method, linearity was found between contrast media concentration and ER. On the other hand, linearity was not found between contrast media concentration and SI. For calculation of ER using Gd-EOB-DTPA, a more correct ER is obtained by measuring the T(1) value using the variable FA method.
Bhattacharjee, Rituparna; Roy, Ram Kinkar
2014-10-28
In the present study, trends of electronic contribution to molecular electrostatic potential [Vel(r¯)(r=0)], Fukui potential [v(+)f|(r=0) and v(-)f|(r=0)] and hardness potential derivatives [Δ(+)h(k) and Δ(-)h(k)] for isolated atoms as well as atoms in molecules are investigated. The generated numerical values of these three reactivity descriptors in these two electronically different situations are critically analyzed through the relevant formalism. Values of Vel(r¯) (when r → 0, i.e., on the nucleus) are higher for atoms in molecules than that of isolated atoms. In contrast, higher values of v(+)|(r=0) and v(-)|(r=0) are observed for isolated atoms compared to the values for atoms in a molecule. However, no such regular trend is observed for the Δ(+)h(k) and Δ(-)h(k) values, which is attributed to the uncertainty in the Fukui function values of atoms in molecules. The sum of Fukui potential and the sum of hardness potential derivatives in molecules are also critically analyzed, which shows the efficacy of orbital relaxation effects in quantifying the values of these parameters. The chemical consequence of the observed trends of these descriptors in interpreting electron delocalization, electronic relaxation and non-negativity of atomic Fukui function indices is also touched upon. Several commonly used molecules containing carbon as well as heteroatoms are chosen to make the investigation more insightful.
Opelt, Katja; Berg, Christian; Schönmann, Susan; Eberl, Leo; Berg, Gabriele
2007-10-01
Mosses represent ecological niches that harbor a hitherto largely uncharacterized microbial diversity. To investigate which factors affect the biodiversity of bryophyte-associated bacteria, we analyzed the bacterial communities associated with two moss species, which exhibit different ecological behaviors and importance in bog ecosystems, Sphagnum magellanicum and Sphagnum fallax, from six temperate and boreal bogs in Germany and Norway. Furthermore, their surrounding plant communities were studied. Molecular analysis of bacterial communities was determined by single-strand conformation polymorphism (SSCP) analysis using eubacterial and genus-specific primers for the dominant genera Burkholderia and Serratia as well as by sequence analysis of a Burkholderia 16S rRNA gene clone library. Plant communities were analyzed by monitoring the abundance and composition of bryophyte and vascular plant species, and by determining ecological indicator values. Interestingly, we found a high degree of host specificity for associated bacterial and plant communities of both Sphagnum species independent of the geographical region. Calculation of diversity indices on the basis of SSCP gels showed that the S. fallax-associated communities displayed a statistically significant higher degree of diversity than those associated with S. magellanicum. In contrast, analyses of plant communities of Sphagnum-specific habitats resulted in a higher diversity of S. magellanicum-specific habitats for all six sites. The higher content of nutrients in the S. fallax-associated ecosystems can explain higher diversity of microorganisms.
Stress concentration in a cylindrical shell containing a circular hole.
NASA Technical Reports Server (NTRS)
Adams, N. J. I.
1971-01-01
The state of stress in a cylindrical shell containing a circular cutout was determined for axial tension, torsion, and internal pressure loading. The solution was obtained for the shallow shell equations by a variational method. The results were expressed in terms of a nondimensional curvature parameter which was a function of shell radius, shell thickness, and hole radius. The function chosen for the solution was such that when the radius of the cylindrical shell approaches infinity, the flat-plate solution was obtained. The results are compared with solutions obtained by more rigorous analytical methods, and with some experimental results. For small values of the curvature parameter, the agreement is good. For higher values of the curvature parameter, the present solutions indicate a limiting value of stress concentration, which is in contrast to previous results.
Broll, Matthias; Albrecht, Katinka; Tarner, Ingo; Müller-Ladner, Ulf; Strunk, Johannes
2012-01-01
To evaluate the value of grey-scale ultrasonography (US) including power Doppler ultrasonography (PDUS) and low-field magnetic resonance imaging (MRI) for the diagnosis of arthritis in a diagnostic phase III study. Fifty consecutive patients with suspected arthritis were included in the study. Following a standardised protocol, US of the carpus and the metacarpophalangeal (MCP) joints of the dominant hand was performed. Subsequently, low-field MRI was done using standard sequences, with contrast agent (Gadolinium DTPA) administered to 29 patients. In 32 out of 50 patients a clinical diagnosis of arthritis was established. In grey-scale ultrasonography including PDUS, sensitivity and specificity were determined as 0.94 and 0.5, respectively, for synovitis (effusion and hypertrophy), 0.72 and 0.94, respectively, for Doppler signals, and 0.38 and 1.0, respectively, for bone erosions. In low-field MRI, sensitivity and specificity values were 0.77 and 0.75, respectively, for synovitis (when using contrast agent), 0.48 and 0.78, respectively, for bone marrow oedema, and 0.58 and 0.83, respectively, for bone erosion. Both grey-scale ultrasonography including PDUS and low-field MRI are suitable imaging methods for diagnosing arthritis at an early stage. However, PDUS displays a higher specificity and almost the same sensitivity as compared to contrast-enhanced MRI, while being a much simpler and less costly procedure.
Comparison of contrast sensitivity in β-thalassemia patients treated by deferoxamine or deferasirox.
Ghazanfari, Azam; Jafarzadehpour, Ebrahim; Heydarian, Samira; Nowroozpoor Dailami, Kiumars; Karami, Hosein
2018-03-10
To compare contrast sensitivity (CS) in multi-transfused β-thalassemia patients who received deferoxamine with those who received Osveral. In this cross sectional study a total of 60 β-thalassemia patients (30 used deferoxamine and 30 used deferasirox) were regarded as case group and 30 age and sex matched healthy subjects were selected as control group. All subjects had a set of examinations including refraction, visual acuity, Biomicroscopy, ophthalmoscopy and CS. Contrast threshold was assessed with the use of Freiberg visual acuity and contrast test under the mesopic light condition for three frequencies; 1, 5, 15cpd. All data analysis was performed using SPSS, version 17. In visual acuity tests, thalassemic patients did not have any problem. Contrast threshold was higher in thalassemic patients who infuse deferoxamine (1.87±0.63, 1.46±0.81, and 2.96±1.68 in 1, 5, and 15cpd, respectively) than that of those who intake deferasirox (1.74±0.80 (P=0.743), 0.99±0.74 (P=0.047), and 2.42±1.36 (P=0.321) for 1, 5, and 15cpd, respectively), and also than healthy patients (1.33±0.58 (P=0.009), 0.95±0.68 (P=0.022), and 2.24±1.23 (P=0.135) for 1, 5, and 15cpd, respectively). Comparing those who used deferasirox with healthy subjects, contrast threshold was higher in deferasirox group at all special frequencies (P>0.05). No significant relationship was observed between CS values and duration of transfusion, serum ferritin concentration and dose of chelation therapy (P>0.05). CS tests can detect visual disturbance in thalassemic patients before the impairment of visual acuity. It is suggested that CS tests be included in their regular eye examination. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Parraga-Aguado, Isabel; Querejeta, Jose-Ignacio; González-Alcaraz, María-Nazaret; Jiménez-Cárceles, Francisco J; Conesa, Héctor M
2014-01-15
The goal of this work was to assess the selection of the most suitable combination of plant species for the phytomanagement of mine tailings, by comparing among different plant life-forms (grasses, shrubs and trees). A comparison on induced rhizosphere changes generated by four plant species (the grass Piptatherum miliaceum, the shrub Helichrysum decumbens, and the trees, Pinus halepensis and Tetraclinis articulata) and high density vegetation patches (fertility islands) at a mine tailing located at Southeast Spain and the description of their physiological status employing stable isotopes analyses were carried out. The edaphic niches for plant growth were determined by salinity, organic matter and total soil nitrogen while metal(loid)s concentrations played a minor role. Induced changes in plant rhizospheres had a significant impact in soil microbiology. While grasses and shrubs may play an important role in primary ecological succession, trees seem to be the key to the development of fertility islands. The low δ(15)N values (-8.00‰) in P. halepensis needles may reflect higher ectomycorrhizal dependence. Large differences in leaf δ(18)O among the plant species indicated contrasting and complementary water acquisition strategies. Leaf δ(13)C values (-27.6‰) suggested that T. articulata had higher water use efficiency than the rest of species (-29.9‰). The implement of a diverse set of plant species with contrasting life forms for revegetating tailings may result in a more efficient employment of water resources and a higher biodiversity not only in relation to flora but soil microbiology too. Copyright © 2013 Elsevier Ltd. All rights reserved.
Shi, Zuomin; Haworth, Matthew; Feng, Qiuhong; Cheng, Ruimei; Centritto, Mauro
2015-01-01
Plant growth at high elevations necessitates physiological and morphological plasticity to enable photosynthesis (A) under conditions of reduced temperature, increased radiation and the lower partial pressure of atmospheric gases, in particular carbon dioxide (pCO2). Previous studies have observed a wide range of responses to elevation in plant species depending on their adaptation to temperature, elevational range and growth habit. Here, we investigated the effect of an increase in elevation from 2500 to 3500 m above sea level (a.s.l.) on three montane species with contrasting growth habits and leaf economic strategies. While all of the species showed identical increases in foliar δ13C, dark respiration and nitrogen concentration with elevation, contrasting leaf gas exchange and photosynthetic responses were observed between species with different leaf economic strategies. The deciduous shrub Salix atopantha and annual herb Rumex dentatus exhibited increased stomatal (Gs) and mesophyll (Gm) conductance and enhanced photosynthetic capacity at the higher elevation. However, evergreen Quercus spinosa displayed reduced conductance to CO2 that coincided with lower levels of photosynthetic carbon fixation at 3500 m a.s.l. The lower Gs and Gm values of evergreen species at higher elevations currently constrains their rates of A. Future rises in the atmospheric concentration of CO2 ([CO2]) will likely predominantly affect evergreen species with lower specific leaf areas (SLAs) and levels of Gm rather than deciduous species with higher SLA and Gm values. We argue that climate change may affect plant species that compose high-elevation ecosystems differently depending on phenotypic plasticity and adaptive traits affecting leaf economics, as rising [CO2] is likely to benefit evergreen species with thick sclerophyllous leaves. PMID:26433706
NASA Astrophysics Data System (ADS)
Xiong, Shanxin; Li, Shuaishuai; Zhang, Xiangkai; Wang, Ru; Zhang, Runlan; Wang, Xiaoqin; Wu, Bohua; Gong, Ming; Chu, Jia
2018-02-01
The molecular architecture of conducting polymers has a significant impact on their conjugated structure and electrochemical properties. We have investigated the influence of star-shaped structure on the electrochemical and electrochromic properties of polyaniline (PANI). Star-shaped PANI (SPANI) was prepared by copolymerization of aniline with triphenylamine (TPA) using an emulsion polymerization method. With addition of less than 4.0 mol.% TPA, the resulting SPANI exhibited good solubility in xylene with dodecylbenzenesulfonic acid (DBSA) as doping acid. The structure and thermal stability of the SPANI were characterized using Fourier-transform infrared spectroscopy, Raman spectroscopy, and thermogravimetric analysis, and the electrochemical behavior was analyzed by cyclic voltammetry (CV). The electrochromic properties of SPANI were tested using an electrochemical workstation combined with an ultraviolet-visible (UV-Vis) spectrometer. The results show that, with increasing TPA loading, the thermal stability of SPANI increased. With addition of 4.0 mol.% TPA, the weight loss of SPANI was 36.9% at 700°C, much lower than the value of 71.2% for PANI at the same temperature. The low oxidation potential and large enclosed area of the CV curves indicate that SPANI possesses higher electrochemical activity than PANI. Enhanced electrochromic properties including higher optical contrast and better electrochromic stability of SPANI were also obtained. SPANI with 1.6 mol.% TPA loading exhibited the highest optical contrast of 0.71, higher than the values of 0.58 for PANI, 0.66 for SPANI-0.4%, or 0.63 for SPANI-4.0%. Overdosing of TPA resulted in slow switching speed due to slow ion transport in short branched chains of star-shaped PANI electrochromic material. Long-term stability testing confirmed that all the SPANI-based devices exhibited better stability than the PANI-based device.
NASA Astrophysics Data System (ADS)
Possamai, Bianca; Vieira, João P.; Grimm, Alice M.; Garcia, Alexandre M.
2018-03-01
Global climatic phenomena like El Niño events are known to alter hydrological cycles and local abiotic conditions leading to changes in structure and dynamics of terrestrial and aquatic biological communities worldwide. Based on a long-term (19 years) standardized sampling of shallow water estuarine fishes, this study investigated the temporal variability in composition and dominance patterns of trophic guilds in a subtropical estuary (Patos Lagoon estuary, Southern Brazil) and their relationship with local and regional driving forces associated with moderate (2002-2003 and 2009-2010) and very strong (1997-1998 and 2015-2016) El Niño events. Fish species were classified into eight trophic guilds (DTV detritivore, HVP herbivore-phytoplankton, HVM macroalgae herbivore, ISV insectivore, OMN omnivore, PSV piscivore, ZBV zoobenthivore and ZPL zooplanktivore) and their abundances were correlated with environmental factors. Canonical correspondence analysis revealed that less dominant (those comprising < 10% of total abundance) trophic guilds, such as HVP, HVM, ISV, PSV, increased their relative abundance in the estuary during higher rainfall and lower salinity conditions associated with moderate and very strong El Niño events. An opposite pattern was observed for the dominant trophic fish guilds like OMN and, at lesser extent, DTV and ZPL, which had greater association with higher values of salinity and water transparency occurring mostly during non-El Niño conditions. In contrast, ZBV's abundance was not correlated with contrasting environmental conditions, but rather, had higher association with samples characterized by intermediate environmental values. Overall, these findings show that moderate and very strong El Niño events did not substantially disrupt the dominance patterns among trophic fish guilds in the estuary. Rather, they increased trophic estuarine diversity by flushing freshwater fishes with distinct feeding habits into the estuary.
NASA Astrophysics Data System (ADS)
Salazar-Tortosa, D.; Castro, J.; Rubio de Casas, R.; Viñegla, B.; Sánchez-Cañete, E. P.; Villar-Salvador, P.
2018-04-01
Increasing temperatures and decreasing precipitation in large areas of the planet as a consequence of global warming will affect plant growth and survival. However, the impact of climatic conditions will differ across species depending on their stomatal response to increasing aridity, as this will ultimately affect the balance between carbon assimilation and water loss. In this study, we monitored gas exchange, growth and survival in saplings of three widely distributed European pine species (Pinus halepensis, P. nigra and P. sylvestris) with contrasting distribution and ecological requirements in order to ascertain the relationship between stomatal control and plant performance. The experiment was conducted in a common garden environment resembling rainfall and temperature conditions that two of the three species are expected to encounter in the near future. In addition, gas exchange was monitored both at the leaf and at the whole-plant level using a transient-state closed chamber, which allowed us to model the response of the whole plant to increased air evaporative demand (AED). P. sylvestris was the species with lowest survival and performance. By contrast, P. halepensis showed no mortality, much higher growth (two orders of magnitude), carbon assimilation (ca. 14 fold higher) and stomatal conductance and water transpiration (ca. 4 fold higher) than the other two species. As a consequence, P. halepensis exhibited higher values of water-use efficiency than the rest of the species even at the highest values of AED. Overall, the results strongly support that the weaker stomatal control of P. halepensis, which is linked to lower stem water potential, enabled this species to maximize carbon uptake under drought stress and ultimately outperform the more water conservative P. nigra and P. sylvestris. These results suggest that under a hotter drought scenario P. nigra and P. sylvestris would very likely suffer increased mortality, whereas P. halepensis could maintain gas exchange and avoid water-induced growth limitation. This might ultimately foster an expansion of P. halepensis to higher latitudes and elevations.
WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willis, C; Willis, C; Nishino, T
2015-06-15
Purpose: To determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in our clinical operation. Methods: Seventeen gridless AP Chest radiographs from a GE Optima portable digital radiography (DR) unit (Group 1), seventeen (routine) PA Chest radiographs from a GE Discovery DR unit (Group 2), and sixteen gridless (non-routine) PA Chest radiographs from the same Discovery DR unit (Group 3) were chosen for analysis. Groups were selected to represent “sub-standard” (Group 1), “standard-of-care” (Group 2), and images with a gross technical error (Group 3). Group 1 images were acquiredmore » with lower kVp (90 vs. 125), shorter source-to-image distance (127cm vs 183cm) and were expected to have lower quality than images in Group 2. Group 3 was expected to have degraded contrast versus Group 2.This evaluation was approved by the institutional Quality Improvement Assurance Board (QIAB). Images were anonymized and securely transferred to the Duke University Clinical Imaging Physics Group for analysis using software previously described{sup 1} and validated{sup 2}. Image quality for individual images was reported in terms of lung grey level(Lgl); lung noise(Ln); rib-lung contrast(RLc); rib sharpness(Rs); mediastinum detail(Md), noise(Mn), and alignment(Ma); subdiaphragm-lung contrast(SLc); and subdiaphragm area(Sa). Metrics were compared across groups. Results: Metrics agreed with published Quality Consistency Ranges with three exceptions: higher Lgl, lower RLc, and SDc. Higher bit depth (16 vs 12) accounted for higher Lgl values in our images. Values were most internally consistent for Group 2. The most sensitive metric for distinguishing between groups was Mn followed closely by Ln. The least sensitive metrics were Md and RLc. Conclusion: The software appears promising for objectively and automatically identifying substandard images in our operation. The results can be used to establish local quality consistency ranges and action limits per facility preferences.« less
Building an Open-source Simulation Platform of Acoustic Radiation Force-based Breast Elastography
Wang, Yu; Peng, Bo; Jiang, Jingfeng
2017-01-01
Ultrasound-based elastography including strain elastography (SE), acoustic radiation force Impulse (ARFI) imaging, point shear wave elastography (pSWE) and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published virtual simulation platform built for ultrasound quasi-static breast elastography toward acoustic radiation force-based breast elastography. Consequently, the extended virtual breast elastography simulation platform can be used to validate image pixels with known underlying soft tissue properties (i.e. “ground truth”) in complex, heterogeneous media, enhancing confidence in elastographic image interpretations. The proposed virtual breast elastography system inherited four key components from the previously published virtual simulation platform: an ultrasound simulator (Field II), a mesh generator (Tetgen), a finite element solver (FEBio) and a visualization and data processing package (VTK). Using a simple message passing mechanism, functionalities have now been extended to acoustic radiation force-based elastography simulations. Examples involving three different numerical breast models with increasing complexity – one uniform model, one simple inclusion model and one virtual complex breast model derived from magnetic resonance imaging data, were used to demonstrate capabilities of this extended virtual platform. Overall, simulation results were compared with the published results. In the uniform model, the estimated shear wave speed (SWS) values were within 4% compared to the predetermined SWS values. In the simple inclusion and the complex breast models, SWS values of all hard inclusions in soft backgrounds were slightly underestimated, similar to what has been reported. The elastic contrast values and visual observation show that ARFI images have higher spatial resolution, while SSI images can provide higher inclusion-to-background contrast. In summary, our initial results were consistent with our expectations and what have been reported in the literature. The proposed (open-source) simulation platform can serve as a single gateway to perform many elastographic simulations in a transparent manner, thereby promoting collaborative developments. PMID:28075330
Building an open-source simulation platform of acoustic radiation force-based breast elastography
NASA Astrophysics Data System (ADS)
Wang, Yu; Peng, Bo; Jiang, Jingfeng
2017-03-01
Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published virtual simulation platform built for ultrasound quasi-static breast elastography toward acoustic radiation force-based breast elastography. Consequently, the extended virtual breast elastography simulation platform can be used to validate image pixels with known underlying soft tissue properties (i.e. ‘ground truth’) in complex, heterogeneous media, enhancing confidence in elastographic image interpretations. The proposed virtual breast elastography system inherited four key components from the previously published virtual simulation platform: an ultrasound simulator (Field II), a mesh generator (Tetgen), a finite element solver (FEBio) and a visualization and data processing package (VTK). Using a simple message passing mechanism, functionalities have now been extended to acoustic radiation force-based elastography simulations. Examples involving three different numerical breast models with increasing complexity—one uniform model, one simple inclusion model and one virtual complex breast model derived from magnetic resonance imaging data, were used to demonstrate capabilities of this extended virtual platform. Overall, simulation results were compared with the published results. In the uniform model, the estimated shear wave speed (SWS) values were within 4% compared to the predetermined SWS values. In the simple inclusion and the complex breast models, SWS values of all hard inclusions in soft backgrounds were slightly underestimated, similar to what has been reported. The elastic contrast values and visual observation show that ARFI images have higher spatial resolution, while SSI images can provide higher inclusion-to-background contrast. In summary, our initial results were consistent with our expectations and what have been reported in the literature. The proposed (open-source) simulation platform can serve as a single gateway to perform many elastographic simulations in a transparent manner, thereby promoting collaborative developments.
NASA Astrophysics Data System (ADS)
Forbes Inskip, N.; Meredith, P. G.; Gudmundsson, A.
2017-12-01
While considerable effort has been expended on the study of fracture propagation in rocks in recent years, our understanding of how fractures propagate through sedimentary rocks composed of layers with different mechanical and elastic properties remains poor. Yet the mechanical layering is a key parameter controlling the propagation of fractures in sedimentary sequences. Here we report measurements of the contrasting properties of the Lower Lias at Nash Point, South Wales, which comprises a sequence of interbedded shale and limestone layers, and how those properties influence fracture propagation. The static Young's modulus (Estat) of both rock types has been measured parallel and normal to bedding. The shale is highly anisotropic, with Estat varying from 2.4 GPa, in the bedding-normal orientation, to 7.9 GPa, in the bedding-parallel orientation, yielding an anisotropy of 107%. By contrast the limestone has a very low anisotropy of 8%, with Estat values varying from 28.5 GPa, in the bedding-normal orientation, to 26.3 GPa in the bedding-parallel orientation. It follows that for a vertical fracture propagating in this sequence the modulus contrast is by a factor of about 12. This is important because the contrast in elastic properties is a key factor in controlling whether fractures arrest, deflect, or propagate across interfaces between layers in a sequence. Preliminary numerical modelling results (using a finite element modelling software) of induced fractures at Nash Point demonstrate a rotation of the maximum principal compressive stress across interfaces but also the concentration of tensile stress within the more competent (high Estat) limestone layers. The tensile strength (σT), using the Brazil-disk technique, and fracture toughness (KIc), using the semi-circular bend methodology, of both rock types have been measured. Measurements were made in the three principal orientations relative to bedding, Arrester, Divider, and Short-Transverse, and also at 15° intervals between these planes. Again, values for the shale show a high degree of anisotropy; with similar values in the Arrester and Divider orientations, but much lower values in the Short-Transverse orientation. σT and KIc values for the limestone are considerably higher than those for the shale and exhibit no significant anisotropy.
Sendur, M A N; Aksoy, S; Yaman, S; Arik, Z; Tugba Kos, F; Akinci, M B; Civelek, B; Yildirim Ozdemir, N; Uncu, D; Zengin, N
2013-01-01
There is a clinical need to predict the probability of cisplatin-induced nephrotoxicity (CIN) in order to make decisions about patient management and relevant preventive measures. The purpose of this study was to develop a risk prediction methodology of CIN. 197 consecutive cancer patients, whose serum creatinine was measured at least 48 h before every cycle of cisplatin-based chemotherapy, were included in the study. Demographic and clinical data were collected from the patient medical records. Renal function was evaluated at least 48 h before treatment (day 0) of each cycle, based on the Modification of Diet in Renal Disease (MDRD) formula. CIN was defined as a decrease of ≥ 25% in glomerular filtration rate (GFR) compared to baseline GFR values. The mean age of the study population was 54.5±9.6 years. Fifty-eight patients (29.4%) whose GFR had decreased by at least 25% compared to baseline values formed the CIN group, and the remaining 139 patients formed the non-CIN group. No significant differences were noted between the CIN and non-CIN groups in terms of age, gender, body mass index and smoking history. Metastatic disease was similar in both groups (p=0.86). History of hypertension (p=0.81), diabetes mellitus (p=0.72), and cardiovascular disease (p=0.58) were similar in the two groups. Chemotherapeutic agents used concurrently with cisplatin were similar in both groups. Significantly more radiologic examinations using contrast media were performed in the CIN group compared with the non-CIN group (p=0.01). In patients exposed to contrast media within a week before cisplatin administration, the risk of CIN was 2.56-fold higher (957 percent; CI 1.28-5.11) than in patients without such exposure (p=0.009). In patients with exposure to contrast media within a week before cisplatin administration, the risk of CIN was significantly higher than in patients without such an exposure. No additional risk factors for CIN were found in this retrospective observational study.
Evaluation of the spline reconstruction technique for PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kastis, George A., E-mail: gkastis@academyofathens.gr; Kyriakopoulou, Dimitra; Gaitanis, Anastasios
2014-04-15
Purpose: The spline reconstruction technique (SRT), based on the analytic formula for the inverse Radon transform, has been presented earlier in the literature. In this study, the authors present an improved formulation and numerical implementation of this algorithm and evaluate it in comparison to filtered backprojection (FBP). Methods: The SRT is based on the numerical evaluation of the Hilbert transform of the sinogram via an approximation in terms of “custom made” cubic splines. By restricting reconstruction only within object pixels and by utilizing certain mathematical symmetries, the authors achieve a reconstruction time comparable to that of FBP. The authors havemore » implemented SRT in STIR and have evaluated this technique using simulated data from a clinical positron emission tomography (PET) system, as well as real data obtained from clinical and preclinical PET scanners. For the simulation studies, the authors have simulated sinograms of a point-source and three digital phantoms. Using these sinograms, the authors have created realizations of Poisson noise at five noise levels. In addition to visual comparisons of the reconstructed images, the authors have determined contrast and bias for different regions of the phantoms as a function of noise level. For the real-data studies, sinograms of an{sup 18}F-FDG injected mouse, a NEMA NU 4-2008 image quality phantom, and a Derenzo phantom have been acquired from a commercial PET system. The authors have determined: (a) coefficient of variations (COV) and contrast from the NEMA phantom, (b) contrast for the various sections of the Derenzo phantom, and (c) line profiles for the Derenzo phantom. Furthermore, the authors have acquired sinograms from a whole-body PET scan of an {sup 18}F-FDG injected cancer patient, using the GE Discovery ST PET/CT system. SRT and FBP reconstructions of the thorax have been visually evaluated. Results: The results indicate an improvement in FWHM and FWTM in both simulated and real point-source studies. In all simulated phantoms, the SRT exhibits higher contrast and lower bias than FBP at all noise levels, by increasing the COV in the reconstructed images. Finally, in real studies, whereas the contrast of the cold chambers are similar for both algorithms, the SRT reconstructed images of the NEMA phantom exhibit slightly higher COV values than those of FBP. In the Derenzo phantom, SRT resolves the 2-mm separated holes slightly better than FBP. The small-animal and human reconstructions via SRT exhibit slightly higher resolution and contrast than the FBP reconstructions. Conclusions: The SRT provides images of higher resolution, higher contrast, and lower bias than FBP, by increasing slightly the noise in the reconstructed images. Furthermore, it eliminates streak artifacts outside the object boundary. Unlike other analytic algorithms, the reconstruction time of SRT is comparable with that of FBP. The source code for SRT will become available in a future release of STIR.« less
Greater effort increases perceived value in an invertebrate.
Czaczkes, Tomer J; Brandstetter, Birgit; di Stefano, Isabella; Heinze, Jürgen
2018-05-01
Expending effort is generally considered to be undesirable. However, both humans and vertebrates will work for a reward they could also get for free. Moreover, cues associated with high-effort rewards are preferred to low-effort associated cues. Many explanations for these counterintuitive findings have been suggested, including cognitive dissonance (self-justification) or a greater contrast in state (e.g., energy or frustration level) before and after an effort-linked reward. Here, we test whether effort expenditure also increases perceived value in ants, using both classical cue-association methods and pheromone deposition, which correlates with perceived value. In 2 separate experimental setups, we show that pheromone deposition is higher toward the reward that requires more effort: 47% more pheromone deposition was performed for rewards reached via a vertical runway (high effort) compared with ones reached via a horizontal runway (low effort), and deposition rates were 28% higher on rough (high effort) versus smooth (low effort) runways. Using traditional cue-association methods, 63% of ants trained on different surface roughness, and 70% of ants trained on different runway elevations, preferred the high-effort related cues on a Y maze. Finally, pheromone deposition to feeders requiring memorization of one path bifurcation was up to 29% higher than to an identical feeder requiring no learning. Our results suggest that effort affects value perception in ants. This effect may stem from a cognitive process, which monitors the change in a generalized hedonic state before and after reward. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Daikoku, Rie; Saito, Yayoi
2008-11-01
The aim of this study was to investigate the impact of caregiver knowledge and experience on muscle activity and perceived exertion while repositioning bedridden patients. Subjects were 40- to 65-year-old female caregivers divided into novice and experienced groups. Subjects from both groups performed home-care repositioning techniques on bedridden patients while muscle activity was recorded via electromyogram. Recordings were made from four muscles on the subjects' dominant side: the latissimus dorsi, the biceps brachii, the erector spinae, and the rectus femoris. The subjective burden involved in repositioning was also assessed using the rate of perceived exertion (RPE) and visual analog scales (VAS). Rectus femoris percentage of maximum voluntary contraction (%MVC) values were significantly lower than latissimus dorsi, erector spinae, and biceps brachii values in the novice group. %MVC values from the latissimus dorsi and biceps brachii were significantly higher among the novice group compared to the experienced group. RPE ratings from the novice group were significantly higher than those of the experienced group, and there was a non-significant trend for higher VAS values for the low back, arms, and legs in the novice group compared to the experienced group. Novice caregivers tended to change the patient's position by pulling with the upper limbs without using the lower limbs. In contrast, experienced caregivers exerted less energy by communicating with the patient and utilizing the patient's own movements. They used large, distributed muscle groups that effectively harnessed body mechanics and prevented excess exertion.
Rapalino, O; Kamalian, Shervin; Kamalian, Shahmir; Payabvash, S; Souza, L C S; Zhang, D; Mukta, J; Sahani, D V; Lev, M H; Pomerantz, S R
2012-04-01
To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed. Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P < .01). CNR values were also significantly higher at ASIR levels of ≥40% (P < .01). Blinded qualitative review demonstrated significant improvements in perceived image noise, artifacts, and GM-WM differentiation at ASIR levels ≥60% (P < .01). These results demonstrate that the use of ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.
Segal-Caspi, Lihi; Roccas, Sonia; Sagiv, Lilach
2012-10-01
Research has documented a robust stereotype regarding personality attributes related to physical attractiveness (the "what is beautiful is good" stereotype). But do physically attractive women indeed possess particularly attractive inner attributes? Studying traits and values, we investigated two complementary questions: how perceived attractiveness relates to perceived personality, and how it relates to actual personality. First, 118 women reported their traits and values and were videotaped reading the weather forecast. Then, 118 judges rated the traits, values, and attractiveness of the women. As hypothesized, attractiveness correlated with attribution of desirable traits, but not with attribution of values. By contrast, attractiveness correlated with actual values, but not actual traits: Attractiveness correlated with tradition and conformity values (which were contrasted with self-direction values) and with self-enhancement values (which were contrasted with universalism values). Thus, despite the widely accepted "what is beautiful is good" stereotype, our findings suggest that the beautiful strive for conformity rather than independence and for self-promotion rather than tolerance.
Mifflin, Mark D; Hatch, Bryndon B; Sikder, Shameema; Bell, James; Kurz, Christopher J; Moshirfar, Majid
2012-02-01
To determine whether VISX S4 (VISX Inc) custom photorefractive keratectomy (PRK) results in better visual outcomes than VISX S4 conventional PRK. Photorefractive keratectomy was performed on 80 eyes from 40 patients in this randomized, prospective, contralateral eye study. Dominant eyes were randomized to one group with the fellow eye receiving the alternate treatment. Primary outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and root-mean-square (RMS) higher order aberrations. Mean UDVA was -0.023±0.099 (20/19) in the custom group and -0.044±0.080 (20/18) in the conventional group 6 months after surgery (P=.293). Mean CDVA was -0.073±0.067 (20/17) in the custom group and -0.079±0.071 (20/17) in the conventional group 6 months after surgery (P=.659). Total higher order aberration RMS and spherical aberration increased in both groups compared to preoperative values (P<.05). Coma increased in the conventional group (P<.05) whereas it was similar to preoperative values in the custom group. No significant differences were noted in induction of trefoil. Custom and conventional PRK were shown to be safe and effective with excellent visual acuity and contrast sensitivity performance at 6 and 12 months. Conventional PRK induced more coma than custom PRK; however, this did not seem to correlate with clinical outcomes. Copyright 2012, SLACK Incorporated.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.
Thébault, Caroline J; Ramniceanu, Grégory; Michel, Aude; Beauvineau, Claire; Girard, Christian; Seguin, Johanne; Mignet, Nathalie; Ménager, Christine; Doan, Bich-Thuy
2018-06-25
The development of theranostic nanocarriers as an innovative therapy against cancer has been improved by targeting properties in order to optimize the drug delivery to safely achieve its desired therapeutic effect. The aim of this paper is to evaluate the magnetic targeting (MT) efficiency of ultra-magnetic liposomes (UML) into CT26 murine colon tumor by magnetic resonance imaging (MRI). Dynamic susceptibility contrast MRI was applied to assess the bloodstream circulation time. A novel semi-quantitative method called %I 0.25 , based on the intensity distribution in T 2 * -weighted MRI images was developed to compare the accumulation of T 2 contrast agent in tumors with or without MT. To evaluate the efficiency of magnetic targeting, the percentage of pixels under the intensity value I 0.25 (I 0.25 = 0.25(I max - I min )) was calculated on the intensity distribution histogram. This innovative method of processing MRI images showed the MT efficiency by a %I 0.25 that was significantly higher in tumors using MT compared to passive accumulation, from 15.3 to 28.6 %. This methodology was validated by ex vivo methods with an iron concentration that is 3-fold higher in tumors using MT. We have developed a method that allows a semi-quantitative evaluation of targeting efficiency in tumors, which could be applied to different T 2 contrast agents.
Biomechanical Phenotyping of the Murine Aorta: What Is the Best Control?
Bellini, C; Caulk, A W; Li, G; Tellides, G; Humphrey, J D
2017-04-01
The availability of diverse mouse models is revealing increasingly greater information on arterial mechanics, including homeostatic adaptations and pathologic maladaptations to genetic, pharmacological, and surgical manipulations. Fundamental to understanding such biomechanical changes, however, is reliable information on appropriate control vessels. In this paper, we contrast 15 different geometrical and mechanical metrics of biaxial wall mechanics for the ascending aorta across seven different types of possible control mice. We show that there is a comforting similarity across these multiple controls for most, though not all, metrics. In particular, three potential controls, namely, noninduced conditional mice, exhibit higher values of distensibility, an important clinical metric of structural stiffness, and two of these potential controls also have higher values of intrinsic circumferential material stiffness. There is motivation, therefore, to understand better the biomechanical changes that can arise with noninduced Cre-lox or similar approaches for generating mutations conditionally. In cases of germline mutations generated by breeding heterozygous +/- mice, however, the resulting homozygous +/+ mice tend to exhibit properties similar to traditional (C57BL/6) controls.
[Comparison of noise characteristics of direct and indirect conversion flat panel detectors].
Murai, Masami; Kishimoto, Kenji; Tanaka, Katsuhisa; Oota, Kenji; Ienaga, Akinori
2010-11-20
Flat-panel detector (FPD) digital radiography systems have direct and indirect conversion systems, and the 2 conversion systems provide different imaging performances. We measured some imaging performances [input-output characteristic, presampled modulation transfer function (presampled MTF), noise power spectrum (NPS)] of direct and indirect FPD systems. Moreover, some image samples of the NPSs were visually evaluated by the pair comparison method. As a result, the presampled MTF of the direct FPD system was substantially higher than that of the indirect FPD system. The NPS of the direct FPD system had a high value for all spatial frequencies. In contrast, the NPS of the indirect FPD system had a lower value as the frequency became higher. The results of visual evaluations showed the same tendency as that found for NPSs. We elucidated the cause of the difference in NPSs in a simulation study, and we determined that the cause of the difference in the noise components of the direct and indirect FPD systems was closely related to the presampled MTF.
Boddu, S R; Tong, F C; Dehkharghani, S; Dion, J E; Saindane, A M
2014-01-01
Endovascular reconstruction and flow diversion by using the Pipeline Embolization Device is an effective treatment for complex cerebral aneurysms. Accurate noninvasive alternatives to DSA for follow-up after Pipeline Embolization Device treatment are desirable. This study evaluated the accuracy of contrast-enhanced time-resolved MRA for this purpose, hypothesizing that contrast-enhanced time-resolved MRA will be comparable with DSA and superior to 3D-TOF MRA. During a 24-month period, 37 Pipeline Embolization Device-treated intracranial aneurysms in 26 patients underwent initial follow-up by using 3D-TOF MRA, contrast-enhanced time-resolved MRA, and DSA. MRA was performed on a 1.5T unit by using 3D-TOF and time-resolved imaging of contrast kinetics. All patients underwent DSA a median of 0 days (range, 0-68) after MRA. Studies were evaluated for aneurysm occlusion, quality of visualization of the reconstructed artery, and measurable luminal diameter of the Pipeline Embolization Device, with DSA used as the reference standard. The sensitivity, specificity, and positive and negative predictive values of contrast-enhanced time-resolved MRA relative to DSA for posttreatment aneurysm occlusion were 96%, 85%, 92%, and 92%. Contrast-enhanced time-resolved MRA demonstrated superior quality of visualization (P = .0001) and a higher measurable luminal diameter (P = .0001) of the reconstructed artery compared with 3D-TOF MRA but no significant difference compared with DSA. Contrast-enhanced time-resolved MRA underestimated the luminal diameter of the reconstructed artery by 0.965 ± 0.497 mm (27% ± 13%) relative to DSA. Contrast-enhanced time-resolved MRA is a reliable noninvasive method for monitoring intracranial aneurysms following flow diversion and vessel reconstruction by using the Pipeline Embolization Device. © 2014 by American Journal of Neuroradiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, So-Yeon; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 110-744; Biomedical Research Institute, Seoul National University College of Medicine, Seoul 110-744
Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantrymore » angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r{sub s}) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI{sub SPORT}) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r{sub s} values of contrast to the global gamma passing rates with criteria of 2%/2 mm, 2%/1 mm, and 1%/2 mm were 0.536, 0.473, and 0.718, respectively. The respective values for variance were 0.551, 0.481, and 0.688. In the case of local gamma passing rates, the r{sub s} values of contrast were 0.547, 0.578, and 0.620, respectively, and those of variance were 0.519, 0.527, and 0.569. All of the r{sub s} values in those cases were statistically significant (p < 0.003). In the cases of global and local gamma passing rates, MI{sub SPORT} showed the highest correlations among the conventional modulation indices. For global passing rates, r{sub s} values of MI{sub SPORT} were −0.420, −0.330, and −0.632, respectively, and those for local passing rates were −0.455, −0.490 and −0.502. The values of r{sub s} of contrast, variance, and MI{sub SPORT} with the MLC errors were −0.863, −0.828, and 0.795, respectively, all with statistical significances (p < 0.001). The correlations with statistical significances between variance and dose-volumetric differences were observed more frequently than the others. Conclusions: The contrast (d = 1) and variance (d = 1) calculated from fluence maps of VMAT plans showed considerable correlations with the plan deliverability, indicating their potential use as indicators for assessing the degree of modulation of VMAT plans. Both contrast and variance consistently showed better performance than the conventional modulation indices for VMAT.« less
NASA Astrophysics Data System (ADS)
Dubois-Dauphin, Quentin; Bonneau, Lucile; Colin, Christophe; Montero-Serrano, Jean-Carlos; Montagna, Paolo; Blamart, Dominique; Hebbeln, Dierk; Van Rooij, David; Pons-Branchu, Edwige; Hemsing, Freya; Wefing, Anne-Marie; Frank, Norbert
2016-06-01
The Nd isotopic composition (ɛNd) of seawater and cold-water coral (CWC) samples from the Gulf of Cádiz and the Alboran Sea, at a depth of 280-827 m were investigated in order to constrain middepth water mass dynamics within the Gulf of Cádiz over the past 40 ka. ɛNd of glacial and Holocene CWC from the Alboran Sea and the northern Gulf of Cádiz reveals relatively constant values (-8.6 to -9.0 and -9.5 to -10.4, respectively). Such values are similar to those of the surrounding present-day middepth waters from the Mediterranean Outflow Water (MOW; ɛNd ˜ -9.4) and Mediterranean Sea Water (MSW; ɛNd ˜ -9.9). In contrast, glacial ɛNd values for CWC collected at thermocline depth (550-827 m) in the southern Gulf of Cádiz display a higher average value (-8.9 ± 0.4) compared to the present-day value (-11.7 ± 0.3). This implies a higher relative contribution of water masses of Mediterranean (MSW) or South Atlantic origin (East Antarctic Intermediate Water, EAAIW). Our study has produced the first evidence of significant radiogenic ɛNd values (˜ -8) at 19, 23-24, and 27 ka, which are coeval with increasing iceberg discharges and a weakening of Atlantic Meridional Overturning Circulation (AMOC). Since MOW ɛNd values remained stable during the last glacial period, it is suggested that these radiogenic ɛNd values most likely reflect an enhanced northward propagation of glacial EAAIW into the eastern Atlantic Basin.
Preference for a Stimulus that Follows a Relatively Aversive Event: Contrast or Delay Reduction?
ERIC Educational Resources Information Center
Singer, Rebecca A.; Berry, Laura M.; Zentall, Thomas R.
2007-01-01
Several types of contrast effects have been identified including incentive contrast, anticipatory contrast, and behavioral contrast. Clement, Feltus, Kaiser, and Zentall (2000) proposed a type of contrast that appears to be different from these others and called it within-trial contrast. In this form of contrast the relative value of a reinforcer…
Mechanisms underlying the influence of saliency on value-based decisions
Chen, Xiaomo; Mihalas, Stefan; Niebur, Ernst; Stuphorn, Veit
2013-01-01
Objects in the environment differ in their low-level perceptual properties (e.g., how easily a fruit can be recognized) as well as in their subjective value (how tasty it is). We studied the influence of visual salience on value-based decisions using a two alternative forced choice task, in which human subjects rapidly chose items from a visual display. All targets were equally easy to detect. Nevertheless, both value and salience strongly affected choices made and reaction times. We analyzed the neuronal mechanisms underlying these behavioral effects using stochastic accumulator models, allowing us to characterize not only the averages of reaction times but their full distributions. Independent models without interaction between the possible choices failed to reproduce the observed choice behavior, while models with mutual inhibition between alternative choices produced much better results. Mutual inhibition thus is an important feature of the decision mechanism. Value influenced the amount of accumulation in all models. In contrast, increased salience could either lead to an earlier start (onset model) or to a higher rate (speed model) of accumulation. Both models explained the data from the choice trials equally well. However, salience also affected reaction times in no-choice trials in which only one item was present, as well as error trials. Only the onset model could explain the observed reaction time distributions of error trials and no-choice trials. In contrast, the speed model could not, irrespective of whether the rate increase resulted from more frequent accumulated quanta or from larger quanta. Visual salience thus likely provides an advantage in the onset, not in the processing speed, of value-based decision making. PMID:24167161
Musculoskeletal MRI at 3.0 T and 7.0 T: a comparison of relaxation times and image contrast.
Jordan, Caroline D; Saranathan, Manojkumar; Bangerter, Neal K; Hargreaves, Brian A; Gold, Garry E
2013-05-01
The purpose of this study was to measure and compare the relaxation times of musculoskeletal tissues at 3.0 T and 7.0 T, and to use these measurements to select appropriate parameters for musculoskeletal protocols at 7.0 T. We measured the T₁ and T₂ relaxation times of cartilage, muscle, synovial fluid, bone marrow and subcutaneous fat at both 3.0 T and 7.0 T in the knees of five healthy volunteers. The T₁ relaxation times were measured using a spin-echo inversion recovery sequence with six inversion times. The T₂ relaxation times were measured using a spin-echo sequence with seven echo times. The accuracy of both the T₁ and T₂ measurement techniques was verified in phantoms at both magnetic field strengths. We used the measured relaxation times to help design 7.0 T musculoskeletal protocols that preserve the favorable contrast characteristics of our 3.0 T protocols, while achieving significantly higher resolution at higher SNR efficiency. The T₁ relaxation times in all tissues at 7.0 T were consistently higher than those measured at 3.0 T, while the T₂ relaxation times at 7.0 T were consistently lower than those measured at 3.0 T. The measured relaxation times were used to help develop high resolution 7.0 T protocols that had similar fluid-to-cartilage contrast to that of the standard clinical 3.0 T protocols for the following sequences: proton-density-weighted fast spin-echo (FSE), T₂-weighted FSE, and 3D-FSE-Cube. The T₁ and T₂ changes were within the expected ranges. Parameters for musculoskeletal protocols at 7.0 T can be optimized based on these values, yielding improved resolution in musculoskeletal imaging with similar contrast to that of standard 3.0 T clinical protocols. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Culture, emotion regulation, and adjustment.
Matsumoto, David; Yoo, Seung Hee; Nakagawa, Sanae
2008-06-01
This article reports differences across 23 countries on 2 processes of emotion regulation--reappraisal and suppression. Cultural dimensions were correlated with country means on both and the relationship between them. Cultures that emphasized the maintenance of social order--that is, those that were long-term oriented and valued embeddedness and hierarchy--tended to have higher scores on suppression, and reappraisal and suppression tended to be positively correlated. In contrast, cultures that minimized the maintenance of social order and valued individual Affective Autonomy and Egalitarianism tended to have lower scores on Suppression, and Reappraisal and Suppression tended to be negatively correlated. Moreover, country-level emotion regulation was significantly correlated with country-level indices of both positive and negative adjustment. (PsycINFO Database Record (c) 2008 APA, all rights reserved).
Contrast-enhanced sonography in pediatrics.
McCarville, M Beth
2011-05-01
Microbubble US contrast agents are composed of an outer shell of protein, phospholipid or polymer that encase air or perfluorocarbon gas. These contrast agents have been widely used in adult cardiology patients to improve endocardial border delineation and have been proved safe and well tolerated in this patient population. There is also a growing body of literature elucidating the value of contrast-enhanced sonography to distinguish benign from malignant liver lesions in adults and to characterize non-hepatic adult malignancies. Because these agents have not been approved for pediatric use in many countries, less is known of the value of contrast-enhanced sonography in children. In this review I will discuss several proven and potential pediatric applications of contrast-enhanced sonography.
Peterson, Sarah; Ackerman, Joshua T.; Eagles-Smith, Collin A.
2017-01-01
Environmental contaminants are a concern for animal health, but contaminant exposure can also be used as a tracer of foraging ecology. In particular, mercury (Hg) concentrations are highly variable among aquatic and terrestrial food webs as a result of habitat- and site-specific biogeochemical processes that produce the bioaccumulative form, methylmercury (MeHg). We used stable isotopes and total Hg (THg) concentrations of a generalist consumer, the California gull (Larus californicus), to examine foraging ecology and illustrate the utility of using Hg contamination as an ecological tracer under certain conditions. We identified four main foraging clusters of gulls during pre-breeding and breeding, using a traditional approach based on light stable isotopes. The foraging cluster with the highest δ15N and δ34S values in gulls (cluster 4) had mean blood THg concentrations 614% (pre-breeding) and 250% (breeding) higher than gulls with the lowest isotope values (cluster 1). Using a traditional approach of stable-isotope mixing models, we showed that breeding birds with a higher proportion of garbage in their diet (cluster 2: 63–82% garbage) corresponded to lower THg concentrations and lower δ15N and δ34S values. In contrast, gull clusters with higher THg concentrations, which were more enriched in 15N and 34S isotopes, consumed a higher proportion of more natural, estuarine prey. δ34S values, which change markedly across the terrestrial to marine habitat gradient, were positively correlated with blood THg concentrations in gulls. The linkage we observed between stable isotopes and THg concentrations suggests that Hg contamination can be used as an additional tool for understanding animal foraging across coastal habitat gradients.
Li, Zhiwei; Ai, Tao; Hu, Yiqi; Yan, Xu; Nickel, Marcel Dominik; Xu, Xiao; Xia, Liming
2018-01-01
To investigate the application of whole-lesion histogram analysis of pharmacokinetic parameters for differentiating malignant from benign breast lesions on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In all, 92 women with 97 breast lesions (26 benign and 71 malignant lesions) were enrolled in this study. Patients underwent dynamic breast MRI at 3T using a prototypical CAIPIRINHA-Dixon-TWIST-VIBE (CDT-VIBE) sequence and a subsequent surgery or biopsy. Inflow rate of the agent between plasma and interstitium (K trans ), outflow rate of agent between interstitium and plasma (K ep ), extravascular space volume per unit volume of tissue (v e ) including mean value, 25th/50th/75th/90th percentiles, skewness, and kurtosis were then calculated based on the whole lesion. A single-sample Kolmogorov-Smirnov test, paired t-test, and receiver operating characteristic curve (ROC) analysis were used for statistical analysis. Malignant breast lesions had significantly higher K trans , K ep , and lower v e in mean values, 25th/50th/75th/90th percentiles, and significantly higher skewness of v e than benign breast lesions (all P < 0.05). There was no significant difference in kurtosis values between malignant and benign breast lesions (all P > 0.05). The 90th percentile of K trans , the 90th percentile of K ep , and the 50th percentile of v e showed the greatest areas under the ROC curve (AUC) for each pharmacokinetic parameter derived from DCE-MRI. The 90th percentile of K ep achieved the highest AUC value (0.927) among all histogram-derived values. The whole-lesion histogram analysis of pharmacokinetic parameters can improve the diagnostic accuracy of breast DCE-MRI with the CDT-VIBE technique. The 90th percentile of K ep may be the best indicator in differentiation between malignant and benign breast lesions. 4 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2018;47:91-96. © 2017 International Society for Magnetic Resonance in Medicine.
Bao, Shixing; Watanabe, Yoshiyuki; Takahashi, Hiroto; Tanaka, Hisashi; Arisawa, Atsuko; Matsuo, Chisato; Wu, Rongli; Fujimoto, Yasunori; Tomiyama, Noriyuki
2018-05-31
This study aimed to determine whether whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) and apparent diffusion coefficient (ADC) for contrast-enhancing lesions can be used to differentiate between glioblastoma (GBM) and primary central nervous system lymphoma (PCNSL). From 20 patients, 9 with PCNSL and 11 with GBM without any hemorrhagic lesions, underwent MRI, including diffusion-weighted imaging and dynamic susceptibility contrast perfusion-weighted imaging before surgery. Histogram analysis of nCBV and ADC from whole-tumor voxels in contrast-enhancing lesions was performed. An unpaired t-test was used to compare the mean values for each type of tumor. A multivariate logistic regression model (LRM) was performed to classify GBM and PCNSL using the best parameters of ADC and nCBV. All nCBV histogram parameters of GBMs were larger than those of PCNSLs, but only average nCBV was statistically significant after Bonferroni correction. Meanwhile, ADC histogram parameters were also larger in GBM compared to those in PCNSL, but these differences were not statistically significant. According to receiver operating characteristic curve analysis, the nCBV average and ADC 25th percentile demonstrated the largest area under the curve with values of 0.869 and 0.838, respectively. The LRM combining these two parameters differentiated between GBM and PCNSL with a higher area under the curve value (Logit (P) = -21.12 + 10.00 × ADC 25th percentile (10 -3 mm 2 /s) + 5.420 × nCBV mean, P < 0.001). Our results suggest that whole-tumor histogram analysis of nCBV and ADC combined can be a valuable objective diagnostic method for differentiating between GBM and PCNSL.
Kinner, Sonja; Maderwald, Stefan; Albert, Juliane; Parohl, Nina; Corot, Claire; Robert, Philippe; Baba, Hideo A; Barkhausen, Jörg
2013-12-01
To investigate the feasibility and performance of 7T magnetic resonance imaging compared to 1.5T imaging to discriminate benign (normal and inflammatory changed) from tumor-bearing lymph nodes in rabbits using ultrasmall particles of iron oxide (USPIO)-based contrast agents. Six New Zealand White rabbits were inoculated with either complete Freund's adjuvant cell suspension (n = 3) to induce reactively enlarged lymph nodes or with VX2 tumor cells to produce metastatic lymph nodes (n = 3). Image acquisition was performed before and 24 hours after bolus injection of an USPIO contrast agent at 1.5T and afterward at 7T using T1-weighted and T2*-weighted sequences. Sensitivities, specificities, and negative and positive predictive values for the detection of lymph node metastases were calculated for both field strengths with histopathology serving as reference standard. Sizes of lymph nodes with no, inflammatory, and malignant changes were compared using a Mann-Whitney U-test. All 24 lymph nodes were detected at 1.5T as well as at 7T. At 1.5T, sensitivity amounted to 0.67, while specificity reached a value of 1. At the higher field strength (7T), imaging was able to reach sensitivity and specificity values of 1. No statistical differences were detected concerning lymph node sizes. Magnetic resonance lymphography with USPIO contrast agents allows for differentiation of normal and reactively enlarged lymph nodes compared to metastatic nodes. First experiments at 7T show promising results compared to 1.5T, which have to be evaluated in further trials. Copyright © 2013. Published by Elsevier Inc.
Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A
2018-02-01
Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P = .003). Conclusion Iron-based contrast agents are promising as alternatives for contrast enhancement at T1-weighted MR imaging and have the potential to contribute to the safety of MR imaging. © RSNA, 2017 Online supplemental material is available for this article.
Effects of cadmium on bioaccumulation and biochemical stress response in rice (Oryza sativa L.).
Xie, Pan-pan; Deng, Juan-wei; Zhang, Hui-min; Ma, You-hua; Cao, De-ju; Ma, Ru-xiao; Liu, Ren-jing; Liu, Cheng; Liang, Yue-gan
2015-12-01
This study investigated the effects of various Cd concentrations on the bioaccumulation, antioxidative defense, and stress responses of rice (Oryza sativa L.). The distribution characteristics of Cd in rice were in the following order: roots>stems>grains. The bioconcentration factor values of Cd increased at concentrations lower than 3.00 mg Cd/kg and approximately decreased to a constant value at concentrations higher than 3.00 mg Cd/kg. Rice showed a higher Cd accumulation potential at low Cd concentrations than at high Cd concentrations. The Freundlich isotherm model described well the adsorption isotherms of Cd in rice roots. The biosorption mechanism of rice roots was determined to be cooperative adsorption. The malondialdehyde (MDA) content increased at a concentration range of 0.00-5.00 mg/L, indicating the enhancement of lipid peroxidation. By contrast, the MDA content slightly decreased at concentrations higher than 5.00 mg/L. Peroxidase (POD) activity exhibited active response to oxidative stress at concentrations lower than 5.00 mg/L but was inhibited at concentrations higher than 5.00 mg/L. The response to Cd stress of the N-H, O-H and C-O functional groups in rice shoots was observed via Fourier transform infrared spectroscopy. Copyright © 2015 Elsevier Inc. All rights reserved.
Silkosessak, O; Jacobs, R; Bogaerts, R; Bosmans, H; Panmekiate, S
2014-01-01
Objectives: To determine the optimal kVp setting for a particular cone beam CT (CBCT) device by maximizing technical image quality at a fixed radiation dose. Methods: The 3D Accuitomo 170 (J. Morita Mfg. Corp., Kyoto, Japan) CBCT was used. The radiation dose as a function of kVp was measured in a cylindrical polymethyl methacrylate (PMMA) phantom using a small-volume ion chamber. Contrast-to-noise ratio (CNR) was measured using a PMMA phantom containing four materials (air, aluminium, polytetrafluoroethylene and low-density polyethylene), which was scanned using 180 combinations of kVp/mA, ranging from 60/1 to 90/8. The CNR was measured for each material using PMMA as background material. The pure effect of kVp and mAs on the CNR values was analysed. Using a polynomial fit for CNR as a function of mA for each kVp value, the optimal kVp was determined at five dose levels. Results: Absorbed doses ranged between 0.034 mGy mAs−1 (14 × 10 cm, 60 kVp) and 0.108 mGy mAs−1 (14 × 10 cm, 90 kVp). The relation between kVp and dose was quasilinear (R2 > 0.99). The effect of mA and kVp on CNR could be modelled using a second-degree polynomial. At a fixed dose, there was a tendency for higher CNR values at increasing kVp values, especially at low dose levels. A dose reduction through mA was more efficient than an equivalent reduction through kVp in terms of image quality deterioration. Conclusions: For the investigated CBCT model, the most optimal contrast at a fixed dose was found at the highest available kVp setting. There is great potential for dose reduction through mA with a minimal loss in image quality. PMID:24708447
Hickethier, Tilman; Iuga, Andra-Iza; Lennartz, Simon; Hauger, Myriam; Byrtus, Jonathan; Luetkens, Julian A; Haneder, Stefan; Maintz, David; Doerner, Jonas
We aimed to determine optimal window settings for conventional polyenergetic (PolyE) and virtual monoenergetic images (MonoE) derived from abdominal portal venous phase computed tomography (CT) examinations on a novel dual-layer spectral-detector CT (SDCT). From 50 patients, SDCT data sets MonoE at 40 kiloelectron volt as well as PolyE were reconstructed and best individual window width and level values manually were assessed separately for evaluation of abdominal arteries as well as for liver lesions. Via regression analysis, optimized individual values were mathematically calculated. Subjective image quality parameters, vessel, and liver lesion diameters were measured to determine influences of different W/L settings. Attenuation and contrast-to-noise values were significantly higher in MonoE compared with PolyE. Compared with standard settings, almost all adjusted W/L settings varied significantly and yielded higher subjective scoring. No differences were found between manually adjusted and mathematically calculated W/L settings. PolyE and MonoE from abdominal portal venous phase SDCT examinations require appropriate W/L settings depending on reconstruction technique and assessment focus.
Liu, Xiaohang; Zhou, Liangping; Peng, Weijun; Qian, Min
2011-06-01
Post-contrast diffusion-weighted imaging (DWI) is occasionally necessary when the results of the pre-contrast DWI differ from that of the dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), however, the effects of contrast material on DWI image and apparent diffusion coefficient (ADC) values have not been fully examined. To assess whether the administration of gadolinium-DTPA (Gd-DTPA) significantly affects the DWI of prostate lesions or normal tissue at the 3.0 Tesla magnetic resonance imaging (3.0 T MRI). Fifty-one patients with 52 prostate lesions, including 32 prostate cancer (25 in the peripheral zone [PZ] and seven that could not be confidently located) and 20 benign lesions (11 in PZ and nine in central grand [CG]), underwent echo-planar imaging (EPI)-DWI with b values of 0, 1000 s/mm(2) before and after administration of Gd-DTPA at 3.0 T MRI. Regions of interest (ROI) were drawn in all lesions, 42 normal PZ, 44 CG tissue and air to calculate the signal-to-noise ratio (SNR) and ADC values of lesions and normal tissue, and contrast-to-noise ratio (CNR) of lesions for pre- and post-contrast images. Statistical differences between pre- and post-contrast data were assessed by use of a paired t test. No significant differences between pre- and post-contrast images were found in the CNR of lesions and SNR of all the tissue except CG, which showed a statistically significant decline (9.6%, p < 0.0001) in SNR after contrast relative to the pre-contrast images. The post-contrast ADC values were statistically significantly lower than pre-contrast for prostate cancer (0.80 ± 0.11 mm(2)/s Vs 0.89 ± 0.12 mm(2)/s, p < 0.0001) and benign lesions (1.14 ± 0.30 mm(2)/s vs. 1.2 ± 0.29 mm(2)/s, p < 0.0001). No significant differences were detected for normal tissue. The administration of Gd-DTPA can slightly affect the DWI image quality of the prostate and reduce the ADC value of lesions at 3.0T MRI. Applications of post-contrast DWI require caution in interpretation.
Bustamante, Alcibíades; Freitas, Duarte; Pan, Huiqi; Katzmarzyk, Peter T.; Maia, José
2015-01-01
This study aimed to provide height, body mass, BMI and waist circumference (WC) growth centile charts for school-children, aged 4–17 years, from central Peru, and to compare Peruvian data with North-American and Argentinean references. The sample consisted of 8753 children and adolescents (4130 boys and 4623 girls) aged 4 to 17 years, from four Peruvian cities: Barranco, La Merced, San Ramón and Junín. Height, body mass and WC were measured according to standardized techniques. Centile curves for height, body mass, BMI and WC were obtained separately for boys and girls using the LMS method. Student t-tests were used to compare mean values. Overall boys have higher median heights than girls, and the 50th percentile for body mass increases curvilinearly from 4 years of age onwards. In boys, the BMI and WC 50th percentiles increase linearly and in girls, the increase presents a curvilinear pattern. Peruvian children are shorter, lighter and have higher BMI than their counterparts in the U.S. and Argentina; in contrast, age and sex-specific WC values are lower. Height, body mass and WC of Peruvian children increased with age and variability was higher at older ages. The growth patterns for height, body mass, BMI and WC among Peruvian children were similar to those observed in North-American and Argentinean peers. PMID:25761169
Canopy Level Chlorophyll Fluorescence and the PRI in a Cornfield
NASA Technical Reports Server (NTRS)
Middleton, Elizabeth M.; Cheng, Yen-Ben; Corp, Lawrence A.; Campbell, Petya K. E.; Huemmrich, K. Fred; Zhang, Qingyuan; Kustas, William P.
2012-01-01
Two bio-indicators, the Photochemical Reflectance Index (PRI) and solar-induced red and far-red Chlorophyll Fluorescence (SIF), were derived from directional hyperspectral observations and studied in a cornfield on two contrasting days in the growing season. Both red and far-red SIF exhibited higher values on the day when the canopy in the early senescent stage, but only the far-red SIF showed sensitivity to viewing geometry. Consequently, the red/far-red SIF ratio varied greatly among azimuth positions while the largest values were obtained for the "hotspot" at both growth stages. This ratio was lower (approx.0.88 +/- 0.4) in early July than in August when the ratio approached equivalence (near approx.1). In concert, the PRI exhibited stronger responses to both zenith and azimuth angles and different values on the two growth stages. The potential of using these indices to monitor photosynthetic activities needs further investigation
Wang, Jian; Xiang, Bo; Lin, Hung-yu; Liu, Hong-yu; Freed, Darren; Arora, Rakesh C; Tian, Gang-hong
2015-01-01
Aim: To investigate the relationship between the collateral circulation and contrast-enhanced MR signal change for myocardial infarction (MI) in pigs. Methods: Pigs underwent permanent ligation of two diagonal branches of the left anterior descending artery. First-pass perfusion (FPP) MRI (for detecting myocardial perfusion abnormalities) and delayed enhancement (DE) MRI (for estimating myocardial infarction) using Gd-DTPA were performed at 2 h, 7 d and 4 weeks after the coronary occlusion. Myocardial blood flow (MBF) was evaluated using nonradioactive red-colored microspheres. Histological examination was performed to characterize the infarcts. Results: Acute MI performed at 2 h afterwards was characterized by hypoenhancement in both FPP- and DE-MRI, with small and almost unchanged FPP-signal intensity (SI) and DE-SI due to negligible MBF. Subacute MI detected 7 d afterwards showed small but significantly increaseing FPP-SI, and was visible as a sluggish hyperenhancement in DE-MRI with considerably higher DE-SI compared to the normal myocardium; the MBF approached the half-normal value. Chronic MI detected at 4 weeks afterwards showed increasing FPP-SI comparable to the normal myocardium, and a rapid hyperenhancement in DE-MRI with even higher DE-SI; the MBF was close to the normal value. The MBF was correlated with FPP-SI (r=+0.94, P<0.01) and with the peak DE-SI (r=+0.92, P<0.01) at the three MI stages. Remodeled vessels were observed at intra-infarction and peri-infarction zones during the subacute and chronic periods. Conclusion: Progressive collateral recovery determines the characteristic profiles of contrast-enhanced MRI in acute, subacute and chronic myocardial infarction in pigs. The FPP- and DE-MRI signal profiles not only depend on the loss of tissue viability and enlarged interstitial space, but also on establishing a collateral circulation. PMID:25832427
Redefining the lower statistical limit in x-ray phase-contrast imaging
NASA Astrophysics Data System (ADS)
Marschner, M.; Birnbacher, L.; Willner, M.; Chabior, M.; Fehringer, A.; Herzen, J.; Noël, P. B.; Pfeiffer, F.
2015-03-01
Phase-contrast x-ray computed tomography (PCCT) is currently investigated and developed as a potentially very interesting extension of conventional CT, because it promises to provide high soft-tissue contrast for weakly absorbing samples. For data acquisition several images at different grating positions are combined to obtain a phase-contrast projection. For short exposure times, which are necessary for lower radiation dose, the photon counts in a single stepping position are very low. In this case, the currently used phase-retrieval does not provide reliable results for some pixels. This uncertainty results in statistical phase wrapping, which leads to a higher standard deviation in the phase-contrast projections than theoretically expected. For even lower statistics, the phase retrieval breaks down completely and the phase information is lost. New measurement procedures rely on a linear approximation of the sinusoidal phase stepping curve around the zero crossings. In this case only two images are acquired to obtain the phase-contrast projection. The approximation is only valid for small phase values. However, typically nearly all pixels are within this regime due to the differential nature of the signal. We examine the statistical properties of a linear approximation method and illustrate by simulation and experiment that the lower statistical limit can be redefined using this method. That means that the phase signal can be retrieved even with very low photon counts and statistical phase wrapping can be avoided. This is an important step towards enhanced image quality in PCCT with very low photon counts.
Li, Zhen; Li, Qiong; Shen, Yaqi; Li, Anqin; Li, Haojie; Liang, Lili; Hu, Yao; Hu, Xuemei; Hu, Daoyu
2016-09-01
The aim of this study was to investigate the effect of using low tube voltage, low-concentration contrast media and adaptive statistical iterative reconstruction (ASIR) for reducing the radiation and iodine contrast doses in adrenal and nephrogenic hypertension patients. A total of 148 hypertension patients who were suspected for adrenal lesions or renal artery stenoses were assigned to two groups and. Group A (n=74) underwent a low tube voltage, low molecular weight dextran enhanced multi-detector row spiral CT (MDCT) (80 kVp, 270 mg I/mL contrast agent), and the raw data were reconstructed with standard filtered back projection (FBP) and ASIR at four different levels of blending (20%, 40%, 60% and 80%, respectively). The control group (Group B, n=74) underwent conventional MDCT (120 kVp, 370 mg I/mL contrast agent), and the data were reconstructed with FBP. The CT values, standard deviation (SD), signal-noise-ratio (SNR) and contrast-noise-ratio (CNR) were measured in the renal vessels, normal adrenal tissue, adrenal neoplasms and subcutaneous fat. The volume CT dose index (CTDIvol ) and dose length product (DLP) were recorded, and an effective dose (ED) was obtained. Two-tailed independent t-tests, paired Chi-square tests and Kappa consistency tests were used for statistical analysis of the data. The CTDIvol , DLP and total iodine dose in group A were decreased by 47.8%, 49.0% and 26.07%, respectively, compared to group B (P<.001). In the qualitative quality analysis, the radiologists rated the 60% ASIR the highest. The mean value of noise (SD) was significantly lower in the 40%, 60% and 80% ASIR-A groups compared with FBP-B for all comparisons. Compared to FBP-B, CNR was significantly higher, with 40%, 60% and 80% ASIR in renal artery stems (P<.05). Compared with FBP-B, a significant increase in the SNR of 40%, 60%, or 80% ASIR was observed in all cases (P<.05). Compared with conventional protocols, the use of low tube voltage, low-concentration contrast media and 60% ASIR provides similar enhancement and image quality with a reduced radiation dose and contrast iodine dose. © 2016 John Wiley & Sons Ltd.
The Neurobiology of Reference-Dependent Value Computation
De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.
2009-01-01
A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780
Spithoven, E M; Meijer, E; Borns, C; Boertien, W E; Gaillard, C A J M; Kappert, P; Greuter, M J W; van der Jagt, E; Vart, P; de Jong, P E; Gansevoort, R T
2016-03-01
Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBFMRI) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values. First, we validated RBFMRI measurement using phantoms simulating renal artery hemodynamics. Thereafter, we investigated in a test-set of 21 patients intra- and inter-observer coefficient of variation of RBFMRI. After validation, we measured RBFMRI in a cohort of 91 patients and compared the variability explained by characteristics indicative for disease severity for RBFMRI and RBF measured by continuous hippuran infusion. The correlation in flow measurement using phantoms by phase-contrast MRI was high and fluid collection was high (CCC=0.969). Technical problems that precluded RBFMRI measurement occurred predominantly in patients with a lower eGFR (34% vs. 16%). In subjects with higher eGFRs, variability in RBF explained by disease characteristics was similar for RBFMRI compared to RBFHip, whereas in subjects with lower eGFRs, this was significantly less for RBFMRI. Our study shows that RBF can be measured accurately in ADPKD patients by phase-contrast, but this technique may be less feasible in subjects with a lower eGFR. Renal blood flow (RBF) can be accurately measured by phase-contrast MRI in ADPKD patients. RBF measured by phase-contrast is associated with ADPKD disease severity. RBF measurement by phase-contrast MRI may be less feasible in patients with an impaired eGFR.
Olsson, Anna; Arlig, Asa; Carlsson, Gudrun Alm; Gustafsson, Agnetha
2007-09-01
The image quality of single photon emission computed tomography (SPECT) depends on the reconstruction algorithm used. The purpose of the present study was to evaluate parameters in ordered subset expectation maximization (OSEM) and to compare systematically with filtered back-projection (FBP) for reconstruction of regional cerebral blood flow (rCBF) SPECT, incorporating attenuation and scatter correction. The evaluation was based on the trade-off between contrast recovery and statistical noise using different sizes of subsets, number of iterations and filter parameters. Monte Carlo simulated SPECT studies of a digital human brain phantom were used. The contrast recovery was calculated as measured contrast divided by true contrast. Statistical noise in the reconstructed images was calculated as the coefficient of variation in pixel values. A constant contrast level was reached above 195 equivalent maximum likelihood expectation maximization iterations. The choice of subset size was not crucial as long as there were > or = 2 projections per subset. The OSEM reconstruction was found to give 5-14% higher contrast recovery than FBP for all clinically relevant noise levels in rCBF SPECT. The Butterworth filter, power 6, achieved the highest stable contrast recovery level at all clinically relevant noise levels. The cut-off frequency should be chosen according to the noise level accepted in the image. Trade-off plots are shown to be a practical way of deciding the number of iterations and subset size for the OSEM reconstruction and can be used for other examination types in nuclear medicine.
Lee, We-Kang; Su, Yi-An; Song, Tzu-Jiun; Chiu, Yao-Chu; Lin, Ching-Hung
2014-01-01
The Iowa Gambling Task (IGT) developed by Bechara et al. in 1994 is used to diagnose patients with Ventromedial Medial Prefrontal Cortex (VMPFC) lesions, and it has become a landmark in research on decision making. According to Bechara et al., the manipulation of progressive increments of monetary value can normalize the performance of patients with VMPFC lesions; thus, they developed a computerized version of the IGT. However, the empirical results showed that patients' performances did not improve as a result of this manipulation, which suggested that patients with VMPFC lesions performed myopically for future consequences. Using the original version of the IGT, some IGT studies have demonstrated that increments of monetary value significantly influence the performance of normal subjects in the IGT. However, other research has resulted in inconsistent findings. In this study, we used the computerized IGT (1X-IGT) and manipulated the value contrast of progressive increments (i.e., by designing the 10X-IGT, which contained 10 times of progressive increment) to investigate the influence of value contrast on the performance of normal subjects. The resulting empirical observations indicated that the value contrast (1X- vs. 10X-IGT) of the progressive increment had no effect on the performance of normal subjects. This study also provides a discussion of the issue of value in IGT-related studies. Moreover, we found the "prominent deck B phenomenon" in both versions of the IGT, which indicated that the normal subjects were guided mostly by the gain-loss frequency, rather than by the monetary value contrast. In sum, the behavioral performance of normal subjects demonstrated a low correlation with changes in monetary value, even in the 10X-IGT.
Rychłowska-Pruszyńska, Magdalena; Gajewska, Joanna; Ambroszkiewicz, Jadwiga; Karwacki, Marek; Szamotulska, Katarzyna
2018-01-01
Aim: The aim of this study was to assess the usefulness of bone-specific alkaline phosphatase (BALP) and the extracelluar domain of human epidermal growth factor receptor 2 (ECD/HER-2) measurements in pediatric patients with osteosarcoma as prospective prognostic and predictive markers for monitoring the treatment and early detection of disease recurrence. Material and methods: We studied 22 patients (5 girls, 17 boys) aged 7-20 years with osteosarcoma (OS) treated at the Institute of Mother and Child in Warsaw. All the patients were evaluated for the serum levels of BALP and ECD/HER-2 before treatment, during pre- and postoperative chemotherapy and after the completion of treatment. Healthy children (n=22) were the reference group. The levels of BALP and ECD/HER-2 were measured using immunoenzymatic methods. Results: The values of BALP and ECD/HER-2 proteins were higher (p<0.01; p<0.05, respectively) in patients with osteosarcoma at the time of diagnosis compared with the control group. The values of both markers significantly decreased during chemotherapy in most patients with remission. In contrast to ECD/HER-2, the value of BALP after therapy was higher in patients with progression than with remission (p<0.001). Conclusions: Our results demonstrate the different pattern of BALP and ECD/HER-2 proteins during clinical treatment in patients with osteosarcoma. Higher values of BALP may characterize the progression of the disease and unfavourable prognosis. Further longitudinal studies are necessary to confirm the prognostic values of BALP and ECD/HER-2 proteins in this group of patients.
An image quality comparison study between XVI and OBI CBCT systems.
Kamath, Srijit; Song, William; Chvetsov, Alexei; Ozawa, Shuichi; Lu, Haibin; Samant, Sanjiv; Liu, Chihray; Li, Jonathan G; Palta, Jatinder R
2011-02-04
The purpose of this study is to evaluate and compare image quality characteristics for two commonly used and commercially available CBCT systems: the X-ray Volumetric Imager and the On-Board Imager. A commonly used CATPHAN image quality phantom was used to measure various image quality parameters, namely, pixel value stability and accuracy, noise, contrast to noise ratio (CNR), high-contrast resolution, low contrast resolution and image uniformity. For the XVI unit, we evaluated the image quality for four manufacturer-supplied protocols as a function of mAs. For the OBI unit, we did the same for the full-fan and half-fan scanning modes, which were respectively used with the full bow-tie and half bow-tie filters. For XVI, the mean pixel values of regions of interest were found to generally decrease with increasing mAs for all protocols, while they were relatively stable with mAs for OBI. Noise was slightly lower on XVI and was seen to decrease with increasing mAs, while CNR increased with mAs for both systems. For XVI and OBI, the high-contrast resolution was approximately limited by the pixel resolution of the reconstructed image. On OBI images, up to 6 and 5 discs of 1% and 0.5% contrast, respectively, were visible for a high mAs setting using the full-fan mode, while none of the discs were clearly visible on the XVI images for various mAs settings when the medium resolution reconstruction was used. In conclusion, image quality parameters for XVI and OBI have been quantified and compared for clinical protocols under various mAs settings. These results need to be viewed in the context of a recent study that reported the dose-mAs relationship for the two systems and found that OBI generally delivered higher imaging doses than XVI.
Ultrasound contrast agent imaging: Real-time imaging of the superharmonics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peruzzini, D.; Viti, J.; Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam
2015-10-28
Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performedmore » to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.« less
Wiener, E; Hodler, J; Pfirrmann, C W A
2009-01-01
Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) is a novel method to investigate cartilaginous and fibrocartilaginous structures. To investigate the contrast dynamics in hyaline and fibrous cartilage of the glenohumeral joint after intraarticular injection of gadopentetate dimeglumine. Transverse T(1) maps were acquired on a 1.5T scanner before and after intraarticular injection of 2.0 mmol/l gadopentetate dimeglumine in five cadaveric shoulders using a dual flip angle three-dimensional gradient echo (3D-GRE) sequence. The acquisition time for the T(1) maps was 5 min 5 s for the whole shoulder. Measurements were repeated every 15 min over 2.5 hours. Regions of interest (ROIs) covering the glenoid cartilage and the labrum were drawn to assess the temporal evolution of the relaxation parameters. T(1) of unenhanced hyaline cartilage of the glenoid was 568+/-34 ms. T(1) of unenhanced fibrous cartilage of the labrum was 552+/-38 ms. Significant differences (P=0.002 and 0.03) in the relaxation parameters were already measurable after 15 min. After 2 to 2.5 hours, hyaline and fibrous cartilage still demonstrated decreasing relaxation parameters, with a larger range of the T(1)(Gd) values in fibrous cartilage. T(1) and triangle Delta R(1) values of hyaline and fibrous cartilage after 2.5 hours were 351+/-16 ms and 1.1+/-0.09 s(-1), and 332+/-31 ms and 1.2+/-0.1 s(-1), respectively. A significant decrease in T(1)(Gd) was found 15 min after intraarticular contrast injection. Contrast accumulation was faster in hyaline than in fibrous cartilage. After 2.5 hours, contrast accumulation showed a higher rate of decrease in hyaline cartilage, but neither hyaline nor fibrous cartilage had reached equilibrium.
Yang, Lixia; Xia, Chunmei; Mu, Yuming; Guan, Lina; Wang, Chunmei; Tang, Qi; Verocai, Flavia Gomes; Fonseca, Lea Mirian Barbosa da; Shih, Ming Chi
2016-03-01
Real time myocardial contrast echocardiography (RTMCE) is a cost-effective and simple method to quantify coronary flow reserve (CFR). We aimed to determine the value of RTMCE to predict cardiac events after percutaneous coronary intervention (PCI). We have studied myocardial blood volume (A), velocity (β), flow indexes (MBF, A × β), and vasodilator reserve (stress-to-rest ratios) in 36 patients with acute coronary syndrome (ACS) who underwent PCI. CFR (MBF at stress/MBF at rest) was calculated for each patient. Perfusion scores were used for visual interpretation by MCE and correlation with TIMI flow grade. In qualitative RTMCE assessment, post-PCI visual perfusion scores were higher than pre-PCI (Z = -7.26, P < 0.01). Among 271 arteries with TIMI flow grade 3 post-PCI, 72 (36%) did not reach visual perfusion score 1. The β- and A × β-reserve of the abnormal segments supplied by obstructed arteries increased after PCI comparing to pre-PCI values (P < 0.01). Patients with adverse cardiac events had significantly lower β- and lower A × β-reserve than patients without adverse cardiac events. In the former group, the CFR was ≥ 1.5 both pre- and post-PCI. CFR estimation by RTMCE can quantify myocardial perfusion in patients with ACS who underwent PCI. The parameters β-reserve and CFR combined might predict cardiac events on the follow-up. © 2015, Wiley Periodicals, Inc.
Huang, Hui; Zhu, Zheng-Qiu; Zhou, Zheng-Guo; Chen, Ling-Shan; Zhao, Ming; Zhang, Yang; Li, Hong-Bo; Yin, Li-Ping
2016-12-08
To assess the role of time-intensity curves (TICs) of the normal peripheral zone (PZ) in the identification of biopsy-proven prostate nodules using contrast-enhanced transrectal ultrasound (CETRUS). This study included 132 patients with 134 prostate PZ nodules. Arrival time (AT), peak intensity (PI), mean transit time (MTT), area under the curve (AUC), time from peak to one half (TPH), wash in slope (WIS) and time to peak (TTP) were analyzed using multivariate linear logistic regression and receiver operating characteristic (ROC) curves to assess whether combining nodule TICs with normal PZ TICs improved the prediction of prostate cancer (PCa) aggressiveness. The PI, AUC (p < 0.001 for both), MTT and TPH (p = 0.011 and 0.040 respectively) values of the malignant nodules were significantly higher than those of the benign nodules. Incorporating the PI and AUC values (both, p < 0.001) of the normal PZ TIC, but not the MTT and TPH values (p = 0.076 and 0.159 respectively), significantly improved the AUC for prediction of malignancy (PI: 0.784-0.923; AUC: 0.758-0.891) and assessment of cancer aggressiveness (p < 0.001). Thus, all these findings indicate that incorporating normal PZ TICs with nodule TICs in CETRUS readings can improve the diagnostic accuracy for PCa and cancer aggressiveness assessment.
Ha, Hojin; Hwang, Dongha; Kim, Guk Bae; Kweon, Jihoon; Lee, Sang Joon; Baek, Jehyun; Kim, Young-Hak; Kim, Namkug; Yang, Dong Hyun
2016-07-01
Quantifying turbulence velocity fluctuation is important because it indicates the fluid energy dissipation of the blood flow, which is closely related to the pressure drop along the blood vessel. This study aims to evaluate the effects of scan parameters and the target vessel size of 4D phase-contrast (PC)-MRI on quantification of turbulent kinetic energy (TKE). Comprehensive 4D PC-MRI measurements with various velocity-encoding (VENC), echo time (TE), and voxel size values were carried out to estimate TKE distribution in stenotic flow. The total TKE (TKEsum), maximum TKE (TKEmax), and background noise level (TKEnoise) were compared for each scan parameter. The feasibility of TKE estimation in small vessels was also investigated. Results show that the optimum VENC for stenotic flow with a peak velocity of 125cm/s was 70cm/s. Higher VENC values overestimated the TKEsum by up to six-fold due to increased TKEnoise, whereas lower VENC values (30cm/s) underestimated it by 57.1%. TE and voxel size did not significantly influence the TKEsum and TKEnoise, although the TKEmax significantly increased as the voxel size increased. TKE quantification in small-sized vessels (3-5-mm diameter) was feasible unless high-velocity turbulence caused severe phase dispersion in the reference image. Copyright © 2016 Elsevier Inc. All rights reserved.
Li, M H; Liu, Y; Liu, L S; Li, P X; Chen, Q
2016-05-24
To investigate the real-time tissue elastography and 3D contrast-enhanced ultrasonography(CEUS) in breast lumps differential diagnostic value. A total of 126 patients (180 lumps) with breast mass were retrospectively analyzed from December 2012 to December 2014 in Tumor Hospital Affiliated To Xinjiang Medical University.All patients were divided into three groups by using stratified random method.Each group was detected by real-time tissue elastography, 3D CEUS and two joint inspection.Each group of 42 cases (60 lumps) was confirmed by the pathological results as gold standard.Diagnostic sensitivity, specificity and coincidence rate of different methods were compared. The benign masses of ultrasound contrast showed the punctate, linear and nodular enhancement, and the border of enhancement was smooth.The malignant tumors were mainly dominated by uneven and high enhancement. There was no statistical difference in sensitivity, specificity and coincidence rate between elastography group and 3D CEUS group (64.7% vs 73.5%, 69.2% vs 76.9%, 66.7% vs 75.0%, all P>0.05). The sensitivity, specificity and coincidence rate of two joint inspection group were higher than those of elastography group and 3D CEUS group, the differences were statistically significant (97.1%, 92.3% and 98.3% , all P<0.05). 3D CEUS combined with real-time tissue elastography is of high value in the diagnosis of breast masses.
Shot noise and Fano factor in tunneling in three-band pseudospin-1 Dirac-Weyl systems
NASA Astrophysics Data System (ADS)
Zhu, Rui; Hui, Pak Ming
2017-06-01
Tunneling through a potential barrier of height V0 in a two-dimensional system with a band structure consisting of three bands with a flat band intersecting the touching apices of two Dirac cones is studied. Results of the transmission coefficient at various incident angles, conductivity, shot noise, and Fano factor in this pseudospin-1 Dirac-Weyl system are presented and contrasted with those in graphene which is typical of a pseudospin-1/2 system. The pseudospin-1 system is found to show a higher transmission and suppressed shot noise in general. Significant differences in the shot noise and Fano factor due to the super Klein tunneling effect that allows perfect transmission at all incident angles under certain conditions are illustrated. For Fermi energy EF =V0 / 2, super Klein tunneling leads to a noiseless conductivity that takes on the maximum value 2e2 DkF / (πh) for 0 ≤EF ≤V0. This gives rise to a minimum Fano factor, in sharp contrast with that of a local maximum in graphene. For EF =V0, the band structure of pseudospin-1 system no longer leads to a quantized value of the conductivity as in graphene. Both the conductivity and the shot noise show a minimum with the Fano factor approaching 1/4, which is different from the value of 1/3 in graphene.
Wang, Lixia; Niu, Yanfeng; Kong, Xiangquan; Yu, Qun; Kong, Xiangchuang; Lv, Yinzhang; Shi, Heshui; Li, Chungao; Wu, Wenjun; Wang, Bing; Liu, Dingxi
2016-03-01
To introduce a new 3D magnetic resonance neurography (MRN) method involving a paramagnetic contrast-based T2 effect coupled with an advanced 3D heavily T2W SPACE-STIR high resolution imaging sequence that would enhance the contrast between nervous tissue and surrounding tissues. Thirty subjects (average age, 39.6±17.0 years; 18 male and 12 female) were enrolled, including three patients with brachial plexopathy and 27 healthy volunteers. Subjective scores from two neuroradiologists, evaluating noncontrast MRN (cMRN) and 3D SPACE-STIR contrast enhanced MRN (ceMRN) 3D data using a 3-point scoring system, were compared using Wilcoxon signed-rank test. Contrast-to-noise ratios (CNRs), SNRs, and contrast ratios within the brachial plexus on cMRN vs. ceMRN MIP and source images were also compared using the paired t-test. The average score for cMRN (0.77±0.43) was significantly lower than ceMRN (1.73±0.45) (p<0.001). Lower nerve vs. vein CNRs were found on cMRN vs. ceMRN, respectively (p<0.001 for both source and MIP images). All nerve-to-surrounding tissue contrast ratios (i.e., fat, muscle, veins, and bone) were higher for ceMRN compared with cMRN for both source and MIP images (all p<0.05). The improved 3D visualization of the brachial plexus and its branches, using this new contrast-enhanced MRN method, can provide high resolution imaging which may be of significant value in the assessment of brachial plexopathy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
MRI Post-processing in Pre-surgical Evaluation
Wang, Z. Irene; Alexopoulos, Andreas V.
2016-01-01
Purpose of Review Advanced MRI post-processing techniques are increasingly used to complement visual analysis and elucidate structural epileptogenic lesions. This review summarizes recent developments in MRI post-processing in the context of epilepsy pre-surgical evaluation, with the focus on patients with unremarkable MRI by visual analysis (i.e., “nonlesional” MRI). Recent Findings Various methods of MRI post-processing have been reported to show additional clinical values in the following areas: (1) lesion detection on an individual level; (2) lesion confirmation for reducing the risk of over reading the MRI; (3) detection of sulcal/gyral morphologic changes that are particularly difficult for visual analysis; and (4) delineation of cortical abnormalities extending beyond the visible lesion. Future directions to improve performance of MRI post-processing include using higher magnetic field strength for better signal and contrast to noise ratio, adopting a multi-contrast frame work, and integration with other noninvasive modalities. Summary MRI post-processing can provide essential value to increase the yield of structural MRI and should be included as part of the presurgical evaluation of nonlesional epilepsies. MRI post-processing allows for more accurate identification/delineation of cortical abnormalities, which should then be more confidently targeted and mapped. PMID:26900745
Dysphagia after antireflux fundoplication: endoscopic, radiological and manometric evaluation.
Morais, Drausio Jeferson; Lopes, Luiz Roberto; Andreollo, Nelson Adami
2014-01-01
The transient dysphagia after fundoplication is common and most often disappears until six weeks postoperatively. Analyze a group of patients who presented late and persistent dysphagia postoperatively. Forty-one patients after Nissen fundoplication, 14 male and 27 female, mean age 48 year, were evaluated based on medical history, esophagogastroduodenoscopy, contrast radiographic examination and esophageal manometry. The results were compared with another 19 asymptomatic individuals. Contrast radiographic examination of the esophagus revealed in six cases delayed emptying, characterizing that four patients had achalasia and two diffuse spasm of the esophagus. Esophageal manometry showed that maximal expiratory pressure of the lower sphincter ranged from 10 to 38 mmHg and mean respiratory pressure from 14 to 47 mmHg, values similar to controls. Residual pressure ranged from 5 to 31 mmHg, and 17 patients had the same values as the control group. The residual pressure of the lower sphincter was higher and statistically significant in patients with dysphagia compared with those operated without dysphagia. Future studies individualizing and categorizing each motility disorder, employing other techniques of manometry, and the analysis of the residual pressure may contribute to understand of persistent dysphagia in the postoperative fundoplication.
Varga-Szemes, Akos; Kiss, Pal; Rab, Andras; Suranyi, Pal; Lenkey, Zsofia; Simor, Tamas; Bryant, Robert G.; Elgavish, Gabriel A.
2016-01-01
Purpose MRI contrast agents (CA) whose contrast enhancement remains relatively high even at the higher end of the magnetic field strength range would be desirable. The purpose of this work was to demonstrate such a desired magnetic field dependency of the longitudinal relaxivity for an experimental MRI CA, Gd(ABE-DTTA). Materials and Methods The relaxivity of 0.5mM and 1mM Gd(ABE-DTTA) was measured by Nuclear Magnetic Relaxation Dispersion (NMRD) in the range of 0.0002 to 1T. Two MRI and five NMR instruments were used to cover the range between 1.5 to 20T. Parallel measurement of a Gd-DTPA sample was performed throughout as reference. All measurements were carried out at 37°C and pH 7.4. Results The relaxivity values of 0.5mM and 1mM Gd(ABE-DTTA) measured at 1.5, 3, and 7T, within the presently clinically relevant magnetic field range, were 15.3, 11.8, 12.4 s-1mM-1 and 18.1, 16.7, and 13.5 s-1mM-1, respectively. The control 4 mM Gd-DTPA relaxivities at the same magnetic fields were 3.6, 3.3, and 3.0 s-1mM-1, respectively. Conclusions The longitudinal relaxivity of Gd(ABE-DTTA) measured within the presently clinically relevant field range is three to five times higher than that of most commercially available agents. Thus, Gd(ABE-DTTA) could be a practical choice at any field strength currently used in clinical imaging including those at the higher end. PMID:26872055
Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun
2015-04-01
Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.
Yoon, Ji Hyun; Son, Jung Woo; Chung, Hyemoon; Park, Chul Hwan; Kim, Young-Jin; Chang, Hyuk-Jae; Hong, Geu-Ru; Kim, Tae Hoon; Ha, Jong-Won; Choi, Byoung Wook; Rim, Se-Joong; Chung, Namsik; Choi, Eui-Young
2015-01-01
Post-contrast T1 values are closely related to the degree of myocardial extracellular space expansion. We determined the relationship between post-contrast T1 values and left ventricular (LV) diastolic function, LV remodeling, and neurohormonal activation in patients with dilated cardiomyopathy (DCM). Fifty-nine patients with DCM (mean age, 55 ± 15 years; 41 males and 18 females) who underwent both 1.5T magnetic resonance imaging and echocardiography were enrolled. The post-contrast 10-minute T1 value was generated from inversion time scout images obtained using the Look-Locker inversion recovery sequence and a curve-fitting algorithm. The T1 sample volume was obtained from three interventricular septal points, and the mean T1 value was used for analysis. The N-Terminal pro-B-type natriuretic peptide (NT-proBNP) level was measured in 40 patients. The mean LV ejection fraction was 24 ± 9% and the post-T1 value was 254.5 ± 46.4 ms. The post-contrast T1 value was significantly correlated with systolic longitudinal septal velocity (s'), peak late diastolic velocity of the mitral annulus (a'), the diastolic elastance index (Ed, [E/e']/stroke volume), LV mass/volume ratio, LV end-diastolic wall stress, and LV end-systolic wall stress. In a multivariate analysis without NT-proBNP, T1 values were independently correlated with Ed (β = -0.351, p = 0.016) and the LV mass/volume ratio (β = 0.495, p = 0.001). When NT-proBNP was used in the analysis, NT-proBNP was independently correlated with the T1 values (β = -0.339, p = 0.017). Post-contrast T1 is closely related to LV remodeling, diastolic function, and neurohormonal activation in patients with DCM.
Miszalski-Jamka, Tomasz; Kuntz-Hehner, Stefanie; Schmidt, Harald; Hammerstingl, Christoph; Tiemann, Klaus; Ghanem, Alexander; Troatz, Clemens; Lüderitz, Berndt; Omran, Heyder
2007-07-01
Myocardial contrast echocardiography (MCE) is a new imaging modality for diagnosing coronary artery disease (CAD). The aim of our study was to evaluate feasibility of qualitative myocardial contrast replenishment (RP) assessment during supine bicycle stress MCE and find out cutoff values for such analysis, which could allow accurate detection of CAD. Forty-four consecutive patients, scheduled for coronary angiography (CA) underwent supine bicycle stress two-dimensional echocardiography (2DE). During the same session, MCE was performed at peak stress and post stress. Ultrasound contrast agent (SonoVue) was administered in continuous mode using an infusion pump (BR-INF 100, Bracco Research). Seventeen-segment model of left ventricle was used in analysis. MCE was assessed off-line in terms of myocardial contrast opacification and RP. RP was evaluated on the basis of the number of cardiac cycles required to refill the segment with contrast after its prior destruction with high-power frames. Determination of cutoff values for RP assessment was performed by means of reference intervals and receiver operating characteristic analysis. Quantitative CA was carried out using CAAS system. MCE could be assessed in 42 patients. CA revealed CAD in 25 patients. Calculated cutoff values for RP-analysis (peak-stress RP >3 cardiac cycles and difference between peak stress and post stress RP >0 cardiac cycles) provided sensitive (88%) and accurate (88%) detection of CAD. Sensitivity and accuracy of 2DE were 76% and 79%, respectively. Qualitative RP-analysis based on the number of cardiac cycles required to refill myocardium with contrast is feasible during supine bicycle stress MCE and enables accurate detection of CAD.
Identifying common values among seven health professions: An interprofessional analysis.
Grace, Sandra; Innes, Ev; Joffe, Beverly; East, Leah; Coutts, Rosanne; Nancarrow, Susan
2017-05-01
This article reviews the competency frameworks of seven Australian health professions to explore relationships among health professions of similar status as reflected in their competency frameworks and to identify common themes and values across the professions. Frameworks were compared using a constructivist grounded theory approach to identify key themes, against which individual competencies for each profession were mapped and compared. The themes were examined for underlying values and a higher order theoretical framework was developed. In contrast to classical theories of professionalism that foreground differentiation of professions, our study suggests that the professions embrace a common structure and understanding, based on shared underpinning values. We propose a model of two core values that encompass all identified themes: the rights of the client and the capacity of a particular profession to serve the healthcare needs of clients. Interprofessional practice represents the intersection of the rights of the client to receive the best available healthcare and the recognition of the individual contribution of each profession. Recognising that all health professions adhere to a common value base, and exploring professional similarities and differences from that value base, challenges a paradigm that distinguishes professions solely on scope of practice.
Le, Yuan; Kroeker, Randall; Kipfer, Hal D; Lin, Chen
2012-08-01
To develop a new pulse sequence called time-resolved angiography with stochastic trajectories (TWIST) Dixon for dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). The method combines dual-echo Dixon to generate separated water and fat images with a k-space view-sharing scheme developed for 3D TWIST. The performance of TWIST Dixon was compared with a volume interpolated breathhold examination (VIBE) sequence paired with spectrally selective adiabatic inversion Recovery (SPAIR) and quick fat-sat (QFS) fat-suppression techniques at 3.0T using quantitative measurements of fat-suppression accuracy and signal-to-noise ratio (SNR) efficiency, as well as qualitative breast image evaluations. The water fraction of a uniform phantom was calculated from the following images: 0.66 ± 0.03 for TWIST Dixon; 0.56 ± 0.23 for VIBE-SPAIR, and 0.53 ± 0.14 for VIBE-QFS, while the reference value is 0.70 measured by spectroscopy. For phantoms with contrast (Gd-BOPTA) concentration ranging from 0-6 mM, TWIST Dixon also provides consistently higher SNR efficiency (3.2-18.9) compared with VIBE-SPAIR (2.8-16.8) and VIBE-QFS (2.4-12.5). Breast images acquired with TWIST Dixon at 3.0T show more robust and uniform fat suppression and superior overall image quality compared with VIBE-SPAIR. The results from phantom and volunteer evaluation suggest that TWIST Dixon outperforms conventional methods in almost every aspect and it is a promising method for DCE-MRI and contrast-enhanced perfusion MRI, especially at higher field strength where fat suppression is challenging. Copyright © 2012 Wiley Periodicals, Inc.
Aksoy, Didem; Bammer, Roland; Mlynash, Michael; Venkatasubramanian, Chitra; Eyngorn, Irina; Snider, Ryan W.; Gupta, Sandeep N.; Narayana, Rashmi; Fischbein, Nancy; Wijman, Christine A. C.
2013-01-01
Background Spontaneous intracerebral hemorrhage (ICH) is associated with blood–brain barrier (BBB) injury, which is a poorly understood factor in ICH pathogenesis, potentially contributing to edema formation and perihematomal tissue injury. We aimed to assess and quantify BBB permeability following human spontaneous ICH using dynamic contrast‐enhanced magnetic resonance imaging (DCE MRI). We also investigated whether hematoma size or location affected the amount of BBB leakage. Methods and Results Twenty‐five prospectively enrolled patients from the Diagnostic Accuracy of MRI in Spontaneous intracerebral Hemorrhage (DASH) study were examined using DCE MRI at 1 week after symptom onset. Contrast agent dynamics in the brain tissue and general tracer kinetic modeling were used to estimate the forward leakage rate (Ktrans) in regions of interest (ROI) in and surrounding the hematoma and in contralateral mirror–image locations (control ROI). In all patients BBB permeability was significantly increased in the brain tissue immediately adjacent to the hematoma, that is, the hematoma rim, compared to the contralateral mirror ROI (P<0.0001). Large hematomas (>30 mL) had higher Ktrans values than small hematomas (P<0.005). Ktrans values of lobar hemorrhages were significantly higher than the Ktrans values of deep hemorrhages (P<0.005), independent of hematoma volume. Higher Ktrans values were associated with larger edema volumes. Conclusions BBB leakage in the brain tissue immediately bordering the hematoma can be measured and quantified by DCE MRI in human ICH. BBB leakage at 1 week is greater in larger hematomas as well as in hematomas in lobar locations and is associated with larger edema volumes. PMID:23709564
2014-01-01
Adolescent substance use is one of today’s most important social concerns, with Latino youth exhibiting the highest overall rates of substance use. Recognizing the particular importance of family connection and support for families from Mexican backgrounds, the current study seeks to examine how family obligation values and family assistance behaviors may be a source of protection or risk for substance use among Mexican-American adolescents. Three hundred and eighty-five adolescents (51% female) from Mexican backgrounds completed a questionnaire and daily diary for 14 consecutive days. Results suggest that family obligation values are protective, relating to lower substance use, due, in part, to the links with less association with deviant peers and increased adolescent disclosure. In contrast, family assistance behaviors are a source of risk within high parent-child conflict homes, relating to higher levels of substance use. These findings suggest that cultural values are protective against substance use, but the translation of these values into behaviors can be a risk factor depending upon the relational context of the family. PMID:23532598
2016-01-01
PURPOSE This study inspects the effect of incorporating halloysite nanotubes (HNTs) into polymethyl methacrylate (PMMA) resin on its flexural strength, hardness, and Young's modulus. MATERIALS AND METHODS Four groups of acrylic resin powder were prepared. One group without HNTs was used as a control group and the other three groups contained 0.3, 0.6 and 0.9 wt% HNTs. For each one, flexural strength, Young's modulus and hardness values were measured. One-way ANOVA and Tukey's test were used for comparison (P<.05). RESULTS At lower concentration (0.3 wt%) of HNT, there was a significant increase of hardness values but no significant increase in both flexural strength and Young's modulus values of PMMA resin. In contrast, at higher concentration (0.6 and 0.9 wt%), there was a significant decrease in hardness values but no significant decrease in flexural strength and Young's modulus values compared to those of the control group. CONCLUSION Addition of lower concentration of halloysite nanotubes to denture base materials could improve some of their mechanical properties. Improving the mechanical properties of acrylic resin base material could increase the patient satisfaction. PMID:27350849
Telzer, Eva H; Gonzales, Nancy; Fuligni, Andrew J
2014-02-01
Adolescent substance use is one of today's most important social concerns, with Latino youth exhibiting the highest overall rates of substance use. Recognizing the particular importance of family connection and support for families from Mexican backgrounds, the current study seeks to examine how family obligation values and family assistance behaviors may be a source of protection or risk for substance use among Mexican-American adolescents. Three hundred and eighty-five adolescents (51% female) from Mexican backgrounds completed a questionnaire and daily diary for 14 consecutive days. Results suggest that family obligation values are protective, relating to lower substance use, due, in part, to the links with less association with deviant peers and increased adolescent disclosure. In contrast, family assistance behaviors are a source of risk within high parent-child conflict homes, relating to higher levels of substance use. These findings suggest that cultural values are protective against substance use, but the translation of these values into behaviors can be a risk factor depending upon the relational context of the family.
Experimental feasibility of multistatic holography for breast microwave radar image reconstruction.
Flores-Tapia, Daniel; Rodriguez, Diego; Solis, Mario; Kopotun, Nikita; Latif, Saeed; Maizlish, Oleksandr; Fu, Lei; Gui, Yonsheng; Hu, Can-Ming; Pistorius, Stephen
2016-08-01
The goal of this study was to assess the experimental feasibility of circular multistatic holography, a novel breast microwave radar reconstruction approach, using experimental datasets recorded using a preclinical experimental setup. The performance of this approach was quantitatively evaluated by calculating the signal to clutter ratio (SCR), contrast to clutter ratio (CCR), tumor to fibroglandular response ratio (TFRR), spatial accuracy, and reconstruction time. Five datasets were recorded using synthetic phantoms with the dielectric properties of breast tissue in the 1-6 GHz range using a custom radar system developed by the authors. The datasets contained synthetic structures that mimic the dielectric properties of fibroglandular breast tissues. Four of these datasets the authors covered an 8 mm inclusion that emulated a tumor. A custom microwave radar system developed at the University of Manitoba was used to record the radar responses from the phantoms. The datasets were reconstructed using the proposed multistatic approach as well as with a monostatic holography approach that has been previously shown to yield the images with the highest contrast and focal quality. For all reconstructions, the location of the synthetic tumors in the experimental setup was consistent with the position in the both the monostatic and multistatic reconstructed images. The average spatial error was less than 4 mm, which is half the spatial resolution of the data acquisition system. The average SCR, CCR, and TFRR of the images reconstructed with the multistatic approach were 15.0, 9.4, and 10.0 dB, respectively. In comparison, monostatic images obtained using the datasets from the same experimental setups yielded average SCR, CCR, and TFRR values of 12.8, 4.9, and 5.9 dB. No artifacts, defined as responses generated by the reconstruction method of at least half the energy of the tumor signatures, were noted in the multistatic reconstructions. The average execution time of the images formed using the proposed approach was 4 s, which is one order of magnitude faster than the current state-of-the-art time-domain multistatic breast microwave radar reconstruction algorithms. The images generated by the proposed method show that multistatic holography is capable of forming spatially accurate images in real-time with signal to clutter levels and contrast values higher than other published monostatic and multistatic cylindrical radar reconstruction approaches. In comparison to the monostatic holographic approach, the images generated by the proposed multistatic approach had SCR values that were at least 50% higher. The multistatic images had CCR and TFRR values at least 200% greater than those formed using a monostatic approach.
Zhang, Lijun; Song, Xiantao; Dong, Li; Li, Jianan; Dou, Ruiyu; Fan, Zhanming; An, Jing; Li, Debiao
2018-04-30
The purpose of the work was to evaluate the incremental diagnostic value of free-breathing, contrast-enhanced, whole-heart, 3 T cardiovascular magnetic resonance coronary angiography (CE-MRCA) to stress/rest myocardial perfusion imaging (MPI) and late gadolinium enhancement (LGE) imaging for detecting coronary artery disease (CAD). Fifty-one patients with suspected CAD underwent a comprehensive cardiovascular magnetic resonance (CMR) examination (CE-MRCA, MPI, and LGE). The additive diagnostic value of MRCA to MPI and LGE was evaluated using invasive x-ray coronary angiography (XA) as the standard for defining functionally significant CAD (≥ 50% stenosis in vessels > 2 mm in diameter). 90.2% (46/51) patients (54.0 ± 11.5 years; 71.7% men) completed CE-MRCA successfully. On per-patient basis, compared to MPI/LGE alone or MPI alone, the addition of MRCA resulted in higher sensitivity (100% vs. 76.5%, p < 0.01), no change in specificity (58.3% vs. 66.7%, p = 0.6), and higher accuracy (89.1% vs 73.9%, p < 0.01) for CAD detection (prevalence = 73.9%). Compared to LGE alone, the addition of CE-MRCA resulted in higher sensitivity (97.1% vs. 41.2%, p < 0.01), inferior specificity (83.3% vs. 91.7%, p = 0.02), and higher diagnostic accuracy (93.5% vs. 54.3%, p < 0.01). The inclusion of successful free-breathing, whole-heart, 3 T CE-MRCA significantly improved the sensitivity and diagnostic accuracy as compared to MPI and LGE alone for CAD detection.
Ng, Alex W H; Griffith, James F; Taljanovic, Mihra S; Li, Alvin; Tse, W L; Ho, P C
2013-07-01
To assess dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) as a measure of vascularity in scaphoid delayed-union or non-union. Thirty-five patients (34 male, one female; mean age, 27.4 ± 9.4 years; range, 16-51 years) with scaphoid delayed-union and non-union who underwent DCE MRI of the scaphoid between September 2002 and October 2012 were retrospectively reviewed. Proximal fragment vascularity was classified as good, fair, or poor on unenhanced MRI, contrast-enhanced MRI, and DCE MRI. For DCE MRI, enhancement slope, Eslope comparison of proximal and distal fragments was used to classify the proximal fragment as good, fair, or poor vascularity. Proximal fragment vascularity was similarly graded at surgery in all patients. Paired t test and McNemar test were used for data comparison. Kappa value was used to assess level of agreement between MRI findings and surgical findings. Twenty-five (71 %) of 35 patients had good vascularity, four (11 %) had fair vascularity, and six (17 %) had poor vascularity of the proximal scaphoid fragment at surgery. DCE MRI parameters had the highest correlation with surgical findings (kappa = 0.57). Proximal scaphoid fragments with surgical poor vascularity had a significantly lower Emax and Eslope than those with good vascularity (p = 0.0043 and 0.027). The sensitivity, specificity, positive and negative predictive value and accuracy of DCE MRI in predicting impaired vascularity was 67, 86, 67, 86, and 80 %, respectively, which was better than that seen with unenhanced and post-contrast MRI. Flattened time intensity curves in both proximal and distal fragments were a feature of protracted non-union with a mean time interval of 101.6 ± 95.5 months between injury and MRI. DCE MRI has a higher diagnostic accuracy than either non-enhanced MRI or contrast enhanced MRI for assessing proximal fragment vascularity in scaphoid delayed-union and non-union. For proper interpretation of contrast-enhanced studies in scaphoid vascularity, one needs to incorporate the time frame between injury and MRI.
Wide range of mercury contamination in chicks of southern ocean seabirds.
Blévin, Pierre; Carravieri, Alice; Jaeger, Audrey; Chastel, Olivier; Bustamante, Paco; Cherel, Yves
2013-01-01
Using top predators as sentinels of the marine environment, Hg contamination was investigated within the large subantarctic seabird community of Kerguelen Islands, a remote area from the poorly known Southern Indian Ocean. Chicks of 21 sympatric seabirds presented a wide range of Hg concentrations, with the highest contaminated species containing ~102 times more feather Hg than the less contaminated species. Hence, Kerguelen seabirds encompass the whole range of chick feather Hg values that were previously collected worldwide in poorly industrialized localities. Using stable isotopes, the effects of foraging habitats (reflected by δ(13)C) and trophic positions (reflected by δ(15)N) on Hg concentrations were investigated. Species-related Hg variations were highly and positively linked to feather δ(15)N values, thus highlighting the occurrence of efficient Hg biomagnification processes within subantarctic marine trophic webs. By contrast, Hg contamination overall correlated poorly with feeding habitats, because of the pooling of species foraging within different isotopic gradients corresponding to distinct seabird habitats (benthic, pelagic, neritic and oceanic). However, when focusing on oceanic seabirds, Hg concentration was related to feather δ(13)C values, with species feeding in colder waters (lower δ(13)C values) south of Kerguelen Islands being less prone to be contaminated than species feeding in northern warmer waters (higher δ(13)C values). Within the context of continuous increase in global Hg emissions, Kerguelen Islands that are located far away from anthropogenic sources can be considered as an ideal study site to monitor the temporal trend of global Hg contamination. The present work helps selecting some seabird species as sentinels of environmental pollution according to their high Hg concentrations and their contrasted foraging ecology.
Wide Range of Mercury Contamination in Chicks of Southern Ocean Seabirds
Blévin, Pierre; Carravieri, Alice; Jaeger, Audrey; Chastel, Olivier; Bustamante, Paco; Cherel, Yves
2013-01-01
Using top predators as sentinels of the marine environment, Hg contamination was investigated within the large subantarctic seabird community of Kerguelen Islands, a remote area from the poorly known Southern Indian Ocean. Chicks of 21 sympatric seabirds presented a wide range of Hg concentrations, with the highest contaminated species containing ∼102 times more feather Hg than the less contaminated species. Hence, Kerguelen seabirds encompass the whole range of chick feather Hg values that were previously collected worldwide in poorly industrialized localities. Using stable isotopes, the effects of foraging habitats (reflected by δ13C) and trophic positions (reflected by δ15N) on Hg concentrations were investigated. Species-related Hg variations were highly and positively linked to feather δ15N values, thus highlighting the occurrence of efficient Hg biomagnification processes within subantarctic marine trophic webs. By contrast, Hg contamination overall correlated poorly with feeding habitats, because of the pooling of species foraging within different isotopic gradients corresponding to distinct seabird habitats (benthic, pelagic, neritic and oceanic). However, when focusing on oceanic seabirds, Hg concentration was related to feather δ13C values, with species feeding in colder waters (lower δ13C values) south of Kerguelen Islands being less prone to be contaminated than species feeding in northern warmer waters (higher δ13C values). Within the context of continuous increase in global Hg emissions, Kerguelen Islands that are located far away from anthropogenic sources can be considered as an ideal study site to monitor the temporal trend of global Hg contamination. The present work helps selecting some seabird species as sentinels of environmental pollution according to their high Hg concentrations and their contrasted foraging ecology. PMID:23349912
Xu, Xiao Quan; Choi, Young Jun; Sung, Yu Sub; Yoon, Ra Gyoung; Jang, Seung Won; Park, Ji Eun; Heo, Young Jin; Baek, Jung Hwan; Lee, Jeong Hyun
2016-01-01
To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D(*)), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D(*) and model-free parameters from the DCE-MRI (wash-in, Tmax, Emax, initial AUC60, whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D(*) and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D(*) (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck.
Server, Andrés; Orheim, Tone E Døli; Graff, Bjørn A; Josefsen, Roger; Kumar, Theresa; Nakstad, Per H
2011-05-01
Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region.
Pattern-free thermal modulator via thermal radiation between Van der Waals materials
NASA Astrophysics Data System (ADS)
Liu, Xianglei; Shen, Jiadong; Xuan, Yimin
2017-10-01
Modulating heat flux provides a platform for a plethora of emerging devices such as thermal diodes, thermal transistors, and thermal memories. Here, a pattern-free noncontact thermal modulator is proposed based on the mechanical rotation between two Van der Waals films with optical axes parallel to the surfaces. A modulation contrast can reach a value higher than 5 for hexagonal Boron Nitride (hBN) films separated by a nanoscale gap distance. The dominant radiative heat exchange comes from the excitation of both Type I and Type II hyperbolic surface phonon polaritons (HSPhPs) at the vacuum-hBN interface for different orientations, while the large modulation contrast is mainly attributed to the mismatching Type I HSPhPs induced by rotation. This work opens the possibility to design cheap thermal modulators without relying on nanofabrication techniques, and paves the way to apply natural Van der Waals materials in manipulating heat currents in an active way.
Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.
Altunbas, Cem; Kavanagh, Brian; Alexeev, Timur; Miften, Moyed
2017-08-01
High fraction of scattered radiation in cone-beam CT (CBCT) imaging degrades CT number accuracy and visualization of low contrast objects. To suppress scatter in CBCT projections, we developed a focused, two-dimensional antiscatter grid (2DASG) prototype. In this work, we report on the primary and scatter transmission characteristics of the 2DASG prototype aimed for linac mounted, offset detector geometry CBCT systems in radiation therapy, and compared its performance to a conventional one-dimensional ASG (1DASG). The 2DASG is an array of through-holes separated by 0.1 mm septa that was fabricated from tungsten using additive manufacturing techniques. Through-holes' focusing geometry was designed for offset detector CBCT in Varian TrueBeam system. Two types of ASGs were evaluated: (a) a conventional 1DASG with a grid ratio of 10, (b) the 2DASG prototype with a grid ratio of 8.2. To assess the scatter suppression performance of both ASGs, Scatter-to-primary ratio (SPR) and scatter transmission fraction (Ts) were measured using the beam stop method. Scatter and primary intensities were modulated by varying the phantom thickness between 10 and 40 cm. Additionally, the effect of air gap and bow tie (BT) filter on SPR and Ts were evaluated. Average primary transmission fraction (T P ) and pixel specific primary transmission were also measured for both ASGs. To assess the effect of transmission characteristics on projection image signal-to-noise ratio (SNR), SNR improvement factor was calculated. Improvement in contrast to noise ratio (CNR) was demonstrated using a low contrast object. In comparison to 1DASG, 2DASG reduced SPRs by a factor of 3 to 6 across the range of phantom setups investigated. Ts values for 1D and 2DASGs were in the range of 21 to 29%, and 5 to 14% respectively. 2DASG continued to provide lower SPR and Ts at increased air gap and with BT filter. Tp of 1D and 2DASGs were 70.6% and 84.7% respectively. Due to the septal shadow of the 2DASG, its pixel specific primary transmission values varied between 32.5% and 99.1%. With respect to 1DASG, 2DASG provided up to factor of 1.7 more improvement in SNR across the SPR range investigated. Moreover, 2DASG provided improved visualization of low contrast objects with respect to 1DASG and NOASG setups. When compared to a conventional 1DASG, 2DASG prototype provided noticeably lower SPR and Ts values, indicating its superior scatter suppression performance. 2DASG also provided 19% higher average primary transmission that was attributed to the absence of interseptal spacers and optimized grid geometry. Our results indicate that the combined effect of lower scatter and higher primary transmission provided by 2DASG may potentially translate into more accurate CT numbers and improved contrast resolution in CBCT images. © 2017 American Association of Physicists in Medicine.
Towards optimization in digital chest radiography using Monte Carlo modelling
NASA Astrophysics Data System (ADS)
Ullman, Gustaf; Sandborg, Michael; Dance, David R.; Hunt, Roger A.; Alm Carlsson, Gudrun
2006-06-01
A Monte Carlo based computer model of the x-ray imaging system was used to investigate how various image quality parameters of interest in chest PA radiography and the effective dose E vary with tube voltage (90-150 kV), additional copper filtration (0-0.5 mm), anti-scatter method (grid ratios 8-16 and air gap lengths 20-40 cm) and patient thickness (20-28 cm) in a computed radiography (CR) system. Calculated quantities were normalized to a fixed value of air kerma (5.0 µGy) at the automatic exposure control chambers. Soft-tissue nodules were positioned at different locations in the anatomy and calcifications in the apical region. The signal-to-noise ratio, SNR, of the nodules and the nodule contrast relative to the contrast of bone (C/CB) as well as relative to the dynamic range in the image (Crel) were used as image quality measures. In all anatomical regions, except in the densest regions in the thickest patients, the air gap technique provides higher SNR and contrast ratios than the grid technique and at a lower effective dose E. Choice of tube voltage depends on whether quantum noise (SNR) or the contrast ratios are most relevant for the diagnostic task. SNR increases with decreasing tube voltage while C/CB increases with increasing tube voltage.
Aversive properties of negative incentive shifts in Fischer 344 and Lewis rats
Brewer, Adam; Johnson, Patrick; Stein, Jeff; Schlund, Michael; Williams, Dean C.
2018-01-01
Research on incentive contrast highlights that reward value is not absolute but rather is based upon comparisons we make to rewards we have received and expect to receive. Both human and nonhuman studies on incentive contrast show that shifting from a larger more-valued reward to a smaller less-valued reward is associated with long periods of nonresponding—a negative contrast effect. In this investigation, we used two different genetic rat strains, Fischer 344 and Lewis rats that putatively differ in their sensitivity to aversive stimulation, to assess the aversive properties of large-to-small reward shifts (negative incentive shifts). Additionally, we examined the extent to which increasing cost (fixed-ratio requirements) modulates negative contrast effects. In the presence of a cue that signaled the upcoming reward magnitude, lever pressing was reinforced with one of two different magnitudes of food (large or small). This design created two contrast shifts (small-to-large, large-to-small) and two shifts used as control conditions (small-to-small, large-to-large). Results showed a significant interaction between rat strain and cost requirements only during the negative incentive shift with the emotionally reactive Fischer 344 rats exhibiting significantly longer response latencies with increasing cost, highlighting greater negative contrast. These findings are more consistent with emotionality accounts of negative contrast and results of neurophysiological research that suggests shifting from a large to a small reward is aversive. Findings also highlight how subjective reward value and motivation is a product of gene-environment interactions. PMID:27864048
Rathnayake, Samira; Mongan, John; Torres, Andrew S.; Colborn, Robert; Gao, Dong-Wei; Yeh, Benjamin M; Fu, Yanjun
2016-01-01
To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n=3 using only iodinated intravenous contrast; and n=13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (5 bismuth-, 4 tungsten-, and 4 tantalum-based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (−100 to +100%) for: 1) preference in small bowel wall visualization; and 2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI: 30–44% and 36–45%, p<0.001 both) higher at double-contrast DECT than at conventional CT with enteric tungsten and tantalum contrast, respectively. Median small bowel wall visualization at double-contrast DECT was scored 29 and 35 percentage points (95% CI: 20–35% and 33–39%, p<0.001 both) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI: 15–31% and 28–33%, p<0.001 both) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum- or tungsten-based enteric contrast provide better visualization of small bowel than conventional CT. PMID:26892945
Nguyen, T B; Cron, G O; Mercier, J F; Foottit, C; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Caudrelier, J M; Sinclair, J; Hogan, M J; Thornhill, R E; Cameron, I G
2015-01-01
The prognostic value of dynamic contrast-enhanced MR imaging-derived plasma volume obtained in tumor and the contrast transfer coefficient has not been well-established in patients with gliomas. We determined whether plasma volume and contrast transfer coefficient in tumor correlated with survival in patients with gliomas in addition to other factors such as age, type of surgery, preoperative Karnofsky score, contrast enhancement, and histopathologic grade. This prospective study included 46 patients with a new pathologically confirmed diagnosis of glioma. The contrast transfer coefficient and plasma volume obtained in tumor maps were calculated directly from the signal-intensity curve without T1 measurements, and values were obtained from multiple small ROIs placed within tumors. Survival curve analysis was performed by dichotomizing patients into groups of high and low contrast transfer coefficient and plasma volume. Univariate analysis was performed by using dynamic contrast-enhanced parameters and clinical factors. Factors that were significant on univariate analysis were entered into multivariate analysis. For all patients with gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). In subgroups of high- and low-grade gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). Univariate analysis showed that factors associated with lower survival were age older than 50 years, low Karnofsky score, biopsy-only versus resection, marked contrast enhancement versus no/mild enhancement, high contrast transfer coefficient, and high plasma volume obtained in tumor (P < .05). In multivariate analysis, a low Karnofsky score, biopsy versus resection in combination with marked contrast enhancement, and a high contrast transfer coefficient were associated with lower survival rates (P < .05). In patients with glioma, those with a high contrast transfer coefficient have lower survival than those with low parameters. © 2015 by American Journal of Neuroradiology.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329
Wu, Lu-Yi; Jin, Xiao-Ming; Wang, Si-Yao; Shi, Yin; Zhang, Jian-Ye; Zeng, Xiao-Qing; Ma, Li-Li; Qin, Wei; Zhao, Ji-Meng; Calhoun, Vince D.; Tian, Jie; Wu, Huan-Gan
2016-01-01
Abnormal pain processing in the central nervous system may be related to abdominal pain in patients with Crohn's disease (CD). The purpose of this study was to investigate changes in resting-state brain activity in CD patients in remission and its relationship with the presence of abdominal pain. Twenty-five CD patients with abdominal pain, 25 CD patients without abdominal pain, and 32 healthy subjects were scanned using a 3.0 T functional magnetic resonance imaging (fMRI) scanner. Regional homogeneity (ReHo) was used to assess resting-state brain activity. Daily pain scores were collected 1 week before fMRI scanning. We found that patients with abdominal pain exhibited lower ReHo values in the insula, middle cingulate cortex (MCC), and supplementary motor area, and higher ReHo values in the temporal pole. In contrast, patients without abdominal pain exhibited lower ReHo values in the hippocampal/parahippocampal cortex and higher ReHo values in the dorsomedial prefrontal cortex (all P<0.05, corrected). The ReHo values of the insula and MCC were significantly negatively correlated with daily pain scores for patients with abdominal pain (r=−0.53, P=0.008, and r=−0.61, P=0.002, respectively). These findings suggest that resting-state brain activities are different between remissive CD patients with and without abdominal pain, and that abnormal activities in insula and MCC are closely related to the severity of abdominal pain. PMID:26761381
Morelli, John N; Ai, Fei; Runge, Val M; Zhang, Wei; Li, Xiaoming; Schmitt, Peter; McNeal, Gary; Michaely, Henrick J; Schoenberg, Stefan O; Miller, Matthew; Gerdes, Clint M; Sincleair, Spencer T; Spratt, Heidi; Attenberger, Ulrike I
2012-09-01
To establish the minimum dose required for detection of renal artery stenosis using high temporal resolution, contrast enhanced MR angiography (MRA) in a porcine model. Surgically created renal artery stenoses were imaged with 3 Tesla MR and digital subtraction angiography (DSA) in 12 swine in this IACUC approved protocol. Gadobutrol was injected intravenously at doses of 0.5, 1, 2, and 4 mL for time-resolved MRA (1.5 × 1.5 mm(2) spatial resolution). Region of interest analysis was performed together with stenosis assessment and qualitative evaluation by two blinded readers. Mean signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were statistically significantly less with the 0.5-mL protocol (P < 0.001). There were no statistically significant differences among the other evaluated doses. Both readers found 10/12 cases with the 0.5-mL protocol to be of inadequate diagnostic quality (κ = 1.0). All other scans were found to be adequate for diagnosis. Accuracies in distinguishing between mild/insignificant (<50%) and higher grade stenoses (>50%) were comparable among the higher-dose protocols (sensitivities 73-93%, specificities 62-100%). Renal artery stenosis can be assessed with very low doses (~0.025 mmol/kg bodyweight) of a high concentration, high relaxivity gadolinium chelate formulation in a swine model, results which are promising with respect to limiting exposure to gadolinium based contrast agents. Copyright © 2012 Wiley Periodicals, Inc.
Asayama, Yoshiki; Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Ohtsuka, Takao; Yoshizumi, Tomoharu; Aishima, Shinichi; Oda, Yoshinao; Honda, Hiroshi
2017-06-01
To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] × 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. • Dynamic contrast study can evaluate the aggressiveness of extrahepatic cholangiocarcinoma. • A lower washout ratio was an independent prognostic factor for overall survival. • CT can predict survival and inform decisions on surgical options or chemotherapy.
Spatiotemporal Characteristics for the Depth from Luminance Contrast
Matsubara, Kazuya; Matsumiya, Kazumichi; Shioiri, Satoshi; Takahashi, Shuichi; Hyodo, Yasuhide; Ohashi, Isao
2011-01-01
Images with higher luminance contrast tend to be perceived closer in depth. To investigate a spatiotemporal characteristic of this effect, we evaluated subjective depth of a test stimulus with various spatial and temporal frequencies. For the purpose, the depth of a reference stimulus was matched to that of the test stimulus by changing the binocular disparity. The results showed that the test stimulus was perceived closer with higher luminance contrast for all conditions. Contrast efficiency was obtained from the contrast that provided the subjective depth for each spatiotemporal frequency. The shape of the contrast efficiency function was spatially low-pass and temporally band-pass. This characteristic is different from the one measure for a detection task. This suggests that only subset of contrast signals are used for depth from contrast.
Can delivery systems use cost-effectiveness analysis to reduce healthcare costs and improve value?
Savitz, Lucy A; Savitz, Samuel T
2016-01-01
Understanding costs and ensuring that we demonstrate value in healthcare is a foundational presumption as we transform the way we deliver and pay for healthcare in the U.S. With a focus on population health and payment reforms underway, there is increased pressure to examine cost-effectiveness in healthcare delivery. Cost-effectiveness analysis (CEA) is a type of economic analysis comparing the costs and effects (i.e. health outcomes) of two or more treatment options. The result is expressed as a ratio where the denominator is the gain in health from a measure (e.g. years of life or quality-adjusted years of life) and the numerator is the incremental cost associated with that health gain. For higher cost interventions, the lower the ratio of costs to effects, the higher the value. While CEA is not new, the approach continues to be refined with enhanced statistical techniques and standardized methods. This article describes the CEA approach and also contrasts it to optional approaches, in order for readers to fully appreciate caveats and concerns. CEA as an economic evaluation tool can be easily misused owing to inappropriate assumptions, over reliance, and misapplication. Twelve issues to be considered in using CEA results to drive healthcare delivery decision-making are summarized. Appropriately recognizing both the strengths and the limitations of CEA is necessary for informed resource allocation in achieving the maximum value for healthcare services provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Zhongwei; SOA Key Laboratory for Polar Science, Polar Research Institute of China, Shanghai, 200136; Lu, Quanming
2013-09-15
Supercritical perpendicular collisionless shocks are known to exhibit foot, ramp, and overshoot structures. The shock ramp structure is in a smaller scale in contrast to other microstructures (foot and overshoot) within the shock front. One-dimensional full particle simulations of strictly perpendicular shocks over wide ranges of ion beta β{sub i}, Alfvén Mach number M{sub A}, and ion-to-electron mass ratio m{sub i}/m{sub e} are presented to investigate the impact of plasma parameters on the shock ramp scale. Main results are (1) the ramp scale can be as small as several electron inertial length. (2) The simulations suggest that in a regimemore » below the critical ion beta value, the shock front undergoes a periodic self-reformation and the shock ramp scale is time-varying. At higher ion beta values, the shock front self-reformation is smeared. At still higher ion beta value, the motion of reflected ions is quite diffuse so that they can lead to a quasi-steady shock ramp. Throughout the above three conditions, the shock ramp thickness increases with β{sub i}. (3) The increase (decrease) in Mach number and the decrease (increase) in the beta value have almost equivalent impact on the state (i.e., stationary or nonstationary) of the shock ramp. Both of front and ramp thicknesses are increased with M{sub A}.« less
Watt, Helen M G; Shapka, Jennifer D; Morris, Zoe A; Durik, Amanda M; Keating, Daniel P; Eccles, Jacquelynne S
2012-11-01
In this international, longitudinal study, we explored gender differences in, and gendered relationships among, math-related motivations emphasized in the Eccles (Parsons) et al. (1983) expectancy-value framework, high school math participation, educational aspirations, and career plans. Participants were from Australia, Canada, and the United States (Ns = 358, 471, 418, respectively) in Grades 9/10 at Time 1 and Grades 11/12 at Time 2. The 3 samples came from suburban middle to upper-middle socioeconomic backgrounds, primarily of Anglo-European descent. Multivariate analyses of variance revealed stereotypic gender differences in educational and occupational outcomes only among the Australian sample. Multigroup structural equation models identified latent mean differences where male adolescents held higher intrinsic value for math in the Australian sample and higher ability/success expectancy in both North American samples. Ability/success expectancy was a key predictor in the North American samples, in contrast to intrinsic value in the Australian sample. Attainment/utility ("importance") values were more important for female adolescents' career choices, except in the Australian sample. Findings are interpreted in relation to gender socialization practices, degree and type of early choice, and specialization across settings. Implications are discussed for long-term math engagement and career selection for female and male adolescents. (PsycINFO Database Record (c) 2012 APA, all rights reserved).
Choat, Brendan; Ball, Marilyn C; Luly, Jon G; Donnelly, Christine F; Holtum, Joseph A M
2006-05-01
Diurnal and seasonal patterns of leaf gas exchange and water relations were examined in tree species of contrasting leaf phenology growing in a seasonally dry tropical rain forest in north-eastern Australia. Two drought-deciduous species, Brachychiton australis (Schott and Endl.) A. Terracc. and Cochlospermum gillivraei Benth., and two evergreen species, Alphitonia excelsa (Fenzal) Benth. and Austromyrtus bidwillii (Benth.) Burret. were studied. The deciduous species had higher specific leaf areas and maximum photosynthetic rates per leaf dry mass in the wet season than the evergreens. During the transition from wet season to dry season, total canopy area was reduced by 70-90% in the deciduous species and stomatal conductance (g(s)) and assimilation rate (A) were markedly lower in the remaining leaves. Deciduous species maintained daytime leaf water potentials (Psi(L)) at close to or above wet season values by a combination of stomatal regulation and reduction in leaf area. Thus, the timing of leaf drop in deciduous species was not associated with large negative values of daytime Psi(L) (greater than -1.6 MPa) or predawn Psi(L) (greater than -1.0 MPa). The deciduous species appeared sensitive to small perturbations in soil and leaf water status that signalled the onset of drought. The evergreen species were less sensitive to the onset of drought and g(s) values were not significantly lower during the transitional period. In the dry season, the evergreen species maintained their canopies despite increasing water-stress; however, unlike Eucalyptus species from northern Australian savannas, A and g(s) were significantly lower than wet season values.
NASA Astrophysics Data System (ADS)
Mather, Caroline C.; Skrzypek, Grzegorz; Dogramaci, Shawan; Grierson, Pauline F.
2018-04-01
Groundwater dolocrete occurring within the Fortescue Marsh, a large inland wetland in the Pilbara region of northwest Australia, has been investigated to provide paleoenvironmental and paleohydrological records and further the understanding of low temperature dolomite formation in terrestrial settings over the Quaternary Period. Two major phases of groundwater dolocrete formation are apparent from the presence of two distinct units of dolocrete, based on differences in depth, δ18O values and mineral composition. Group 1 (G1) occurs at depth 20-65 m b.g.l. (below ground level) and contains stoichiometric dolomite with δ18O values of -4.02-0.71‰. Group 2 (G2) is shallower (0-23 m b.g.l.), occurring close to the current groundwater level, and contains Ca-rich dolomite ± secondary calcite with a comparatively lower range of δ18O values (-7.74 and -6.03‰). Modelled δ18O values of paleogroundwater from which older G1 dolomite precipitated indicated highly saline source water, which had similar stable oxygen isotope compositions to relatively old brine groundwater within the Marsh, developed under a different hydroclimatic regime. The higher δ18O values suggest highly evaporitic conditions occurred at the Marsh, which may have been a playa lake to saline mud flat environment. In contrast, G2 dolomite precipitated from comparatively fresher water, and modelled δ18O values suggested formation from mixing between inflowing fresher groundwater with saline-brine groundwater within the Marsh. The δ18O values of the calcite indicates formation from brackish to saline groundwater, which suggests this process may be associated with coeval gypsum dissolution. In contrast to the modern hydrology of the Marsh, which is surface water dependent and driven by a flood and drought regime, past conditions conducive to dolomite precipitation suggest a groundwater dependent system, where shallow groundwaters were influenced by intensive evaporation.
Internationalization Policies: About New Trends and Contrasting Paradigms.
ERIC Educational Resources Information Center
van der Wende, Marijk C.
2001-01-01
Analyzes the contrast between the two main paradigms of higher education internationalization: competition and cooperation. Addresses related questions about the role and position of continental European higher education compared to that of some Anglo-Saxon countries that are leading in the global higher education market. (EV)
Nanoengineered multimodal contrast agent for medical image guidance
NASA Astrophysics Data System (ADS)
Perkins, Gregory J.; Zheng, Jinzi; Brock, Kristy; Allen, Christine; Jaffray, David A.
2005-04-01
Multimodality imaging has gained momentum in radiation therapy planning and image-guided treatment delivery. Specifically, computed tomography (CT) and magnetic resonance (MR) imaging are two complementary imaging modalities often utilized in radiation therapy for visualization of anatomical structures for tumour delineation and accurate registration of image data sets for volumetric dose calculation. The development of a multimodal contrast agent for CT and MR with prolonged in vivo residence time would provide long-lasting spatial and temporal correspondence of the anatomical features of interest, and therefore facilitate multimodal image registration, treatment planning and delivery. The multimodal contrast agent investigated consists of nano-sized stealth liposomes encapsulating conventional iodine and gadolinium-based contrast agents. The average loading achieved was 33.5 +/- 7.1 mg/mL of iodine for iohexol and 9.8 +/- 2.0 mg/mL of gadolinium for gadoteridol. The average liposome diameter was 46.2 +/- 13.5 nm. The system was found to be stable in physiological buffer over a 15-day period, releasing 11.9 +/- 1.1% and 11.2 +/- 0.9% of the total amounts of iohexol and gadoteridol loaded, respectively. 200 minutes following in vivo administration, the contrast agent maintained a relative contrast enhancement of 81.4 +/- 13.05 differential Hounsfield units (ΔHU) in CT (40% decrease from the peak signal value achieved 3 minutes post-injection) and 731.9 +/- 144.2 differential signal intensity (ΔSI) in MR (46% decrease from the peak signal value achieved 3 minutes post-injection) in the blood (aorta), a relative contrast enhancement of 38.0 +/- 5.1 ΔHU (42% decrease from the peak signal value achieved 3 minutes post-injection) and 178.6 +/- 41.4 ΔSI (62% decrease from the peak signal value achieved 3 minutes post-injection) in the liver (parenchyma), a relative contrast enhancement of 9.1 +/- 1.7 ΔHU (94% decrease from the peak signal value achieved 3 minutes post-injection) and 461.7 +/- 78.1 ΔSI (60% decrease from the peak signal value achieved 5 minutes post-injection) in the kidney (cortex) of a New Zealand white rabbit. This multimodal contrast agent, with prolonged in vivo residence time and imaging efficacy, has the potential to bring about improvements in the fields of medical imaging and radiation therapy, particularly for image registration and guidance.
Jiao, Junfeng; Drewnowski, Adam; Moudon, Anne Vernez; Aggarwal, Anju; Oppert, Jean-Michel; Charreire, Helene; Chaix, Basile
2016-12-01
This study analyzed the impact of area residential property values, an objective measure of socioeconomic status (SES), on self-rated health (SRH) in Seattle, Washington and Paris, France. This study brings forth a valuable comparison of SRH between cities that have contrasting urban forms, population compositions, residential segregation, food systems and transportation modes. The SOS (Seattle Obesity Study) was based on a representative sample of 1394 adult residents of Seattle and King County in the United States. The RECORD Study (Residential Environment and Coronary Heart Disease) was based on 7131 adult residents of Paris and its suburbs in France. Socio-demographics, SRH and body weights were obtained from telephone surveys (SOS) and in-person interviews (RECORD). All home addresses were geocoded using ArcGIS 9.3.1 (ESRI, Redlands, CA). Residential property values were obtained from tax records (Seattle) and from real estate sales (Paris). Binary logistic regression models were used to test the associations among demographic and SES variables and SRH. Higher area property values significantly associated with better SRH, adjusting for age, gender, individual education, incomes, and BMI. The associations were significant for both cities. A one-unit increase in body mass index (BMI) was more detrimental to SRH in Seattle than in Paris. In both cities, higher area residential property values were related to a significantly lower obesity risk and better SRH. Ranked residential property values can be useful for health and weight studies, including those involving social inequalities and cross-country comparisons.
Zeng, Qiang; Ling, Chenhan; Shi, Feina; Dong, Fei; Jiang, Biao; Zhang, Jianmin
2018-03-01
Glioma cells may infiltrate beyond the tumor margins revealed on conventional structural images. To investigate whether the presence of a glioma infiltration sign on high b-value diffusion-weighted imaging (DWI) can predict the prognosis of gliomas. Retrospective cohort. Fifty-two patients with gliomas (14 WHO grade II; 13 WHO grade III; 25 WHO grade IV). 3.0T, including a T 1 -weighted contrast-enhanced (T 1 w-CE) sequence, contrast-enhanced T 2 -flair sequence, and a DWI sequence. T 1 w-CE images and contrast-enhanced T 2 -flair images were used for identifying the tumor region for enhancing and nonenhancing gliomas, respectively. The glioma infiltration sign was defined as the presence of a peritumoral abnormal high signal region on DWI map, which was adjacent to the tumor region and had higher signal than surrounding areas. This sign was assessed on a high b-value DWI map with b = 3000 s/mm 2 . For patients with glioma infiltration sign, DWI3000 max , DWI1000 max , ADC3000 min , and ADC1000 min were measured by drawing a region of interest over the peritumoral abnormal high signal region. Survival analysis was conducted by using Cox regression. Glioma infiltration sign was observed in 28 (53.8%) patients. The occurrence rate of this sign was 92.0% in grade IV gliomas, 30.8% in grade III gliomas, and 7.1% in grade II gliomas. The glioma infiltration sign could independently predict both the progression-free survival (hazard ratio [HR], 95% confidence interval [CI] = 8.58 [3.19-23.03], P < 0.001) and overall survival (HR, 95% CI = 11.90 [3.41-41.55], P < 0.001) after adjustment. For patients with glioma infiltration sign, DWI3000 max (P = 0.005) and ADC3000 min (P = 0.008) were both independent predictors of overall survival after adjustment, while DWI1000 max and ADC1000 min were not. The glioma infiltration sign on high b-value DWI is an independent predictor of poor prognosis in glioma patients. High b-value DWI might be a convenient method to detect glioma infiltration. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Velazquez, E Rios; Narayan, V; Grossmann, P
2015-06-15
Purpose: To compare the complementary prognostic value of automated Radiomic features to that of radiologist-annotated VASARI features in TCGA-GBM MRI dataset. Methods: For 96 GBM patients, pre-operative MRI images were obtained from The Cancer Imaging Archive. The abnormal tumor bulks were manually defined on post-contrast T1w images. The contrast-enhancing and necrotic regions were segmented using FAST. From these sub-volumes and the total abnormal tumor bulk, a set of Radiomic features quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the post-contrast T1w images. Minimum-redundancy-maximum-relevance (MRMR) was used to identify the most informative Radiomic, VASARI andmore » combined Radiomic-VASARI features in 70% of the dataset (training-set). Multivariate Cox-proportional hazards models were evaluated in 30% of the dataset (validation-set) using the C-index for OS. A bootstrap procedure was used to assess significance while comparing the C-Indices of the different models. Results: Overall, the Radiomic features showed a moderate correlation with the radiologist-annotated VASARI features (r = −0.37 – 0.49); however that correlation was stronger for the Tumor Diameter and Proportion of Necrosis VASARI features (r = −0.71 – 0.69). After MRMR feature selection, the best-performing Radiomic, VASARI, and Radiomic-VASARI Cox-PH models showed a validation C-index of 0.56 (p = NS), 0.58 (p = NS) and 0.65 (p = 0.01), respectively. The combined Radiomic-VASARI model C-index was significantly higher than that obtained from either the Radiomic or VASARI model alone (p = <0.001). Conclusion: Quantitative volumetric and textural Radiomic features complement the qualitative and semi-quantitative annotated VASARI feature set. The prognostic value of informative qualitative VASARI features such as Eloquent Brain and Multifocality is increased with the addition of quantitative volumetric and textural features from the contrast-enhancing and necrotic tumor regions. These results should be further evaluated in larger validation cohorts.« less
[Atmospheric correction of visible-infrared band FY-3A/MERSI data based on 6S model].
Wu, Yong-Li; Luan, Qing; Tian, Guo-Zhen
2011-06-01
Based on the observation data from the meteorological stations in Taiyuan City and its surrounding areas of Shanxi Province, the atmosphere parameters for 6S model were supplied, and the atmospheric correction of visible-infrared band (precision 250 meters) FY-3A/MERSI data was conducted. After atmospheric correction, the range of visible-infrared band FY-3A/MERSI data was widened, reflectivity increased, high peak was higher, and distribution histogram was smoother. In the meantime, the threshold value of NDVI data reflecting vegetation condition increased, and its high peak was higher, more close to the real data. Moreover, the color synthesis image of correction data showed more abundant information, its brightness increased, contrast enhanced, and the information reflected was more close to real.
Brief communication: Loss and damage from a catastrophic landslide in Nepal
NASA Astrophysics Data System (ADS)
van der Geest, Kees; Schindler, Markus
2016-11-01
This brief communication reports key findings of a recent piece of research that studied the impacts of the 2014 Jure landslide in Sindhupalchok (Nepal) and the effectiveness of household preventive and coping measures. The people-centered methods reveal not just what was lost in the disaster, but also how and why. A key finding of the household survey is that households in higher income groups incurred higher losses in monetary terms, simply because they had more to lose. By contrast, lower-income households lost more in relative terms: the value of their losses amounted to 14 times their annual earnings. Many lower-income households will never fully recover from this blow to their livelihoods and wellbeing. The findings have important implications for discussions on loss and damage valuation, compensation and relief.
NASA Astrophysics Data System (ADS)
Durán, C.; Medina-Sánchez, J. M.; Herrera, G.; Villar-Argaiz, M.; Villafañe, V. E.; Helbling, E. W.; Carrillo, P.
2014-05-01
As a consequence of global change, modifications in the interaction among abiotic stressors on aquatic ecosystems have been predicted. Among other factors, UVR transparency, nutrient inputs and shallower epilimnetic layers could alter the trophic links in the microbial food web. Currently, there are some evidences of higher sensitiveness of aquatic microbial organisms to UVR in opaque lakes. Our aim was to assess the interactive direct and indirect effects of UVR (through the excretion of organic carbon - EOC - by algae), mixing regime and nutrient input on bacterial metabolism. We performed in situ short-term experiments under the following treatments: full sunlight (UVR + PAR, >280 nm) vs. UVR exclusion (PAR only, >400 nm); ambient vs. nutrient addition (phosphorus (P; 30 μg PL-1) and nitrogen (N; up to final N : P molar ratio of 31)); and static vs. mixed regime. The experiments were conducted in three high-mountain lakes of Spain: Enol [LE], Las Yeguas [LY] and La Caldera [LC] which had contrasting UVR transparency characteristics (opaque (LE) vs. clear lakes (LY and LC)). Under ambient nutrient conditions and static regimes, UVR exerted a stimulatory effect on heterotrophic bacterial production (HBP) in the opaque lake but not in the clear ones. Under UVR, vertical mixing and nutrient addition HBP values were lower than under the static and ambient nutrient conditions, and the stimulatory effect that UVR exerted on HBP in the opaque lake disappeared. By contrast, vertical mixing and nutrient addition increased HBP values in the clear lakes, highlighting for a photoinhibitory effect of UVR on HBP. Mixed regime and nutrient addition resulted in negative effects of UVR on HBP more in the opaque than in the clear lakes. Moreover, in the opaque lake, bacterial respiration (BR) increased and EOC did not support the bacterial carbon demand (BCD). In contrast, bacterial metabolic costs did not increase in the clear lakes and the increased nutrient availability even led to higher HBP. Consequently, EOC satisfied BCD in the clear lakes, particularly in the clearest one [LC]. Our results suggest that the higher vulnerability of bacteria to the damaging effects of UVR may be particularly accentuated in the opaque lakes and further recognizes the relevance of light exposure history and biotic interactions on bacterioplankton metabolism when coping with fluctuating radiation and nutrient inputs.
Cordingley, Justine E; Newton, Adrian C; Rose, Robert J; Clarke, Ralph T; Bullock, James M
2015-01-01
While habitat fragmentation represents a major threat to global biodiversity, its impacts on provision of ecosystem services are largely unknown. We analysed biodiversity value and provision of multiple ecosystem services in 110 fragments of lowland heathland ecosystems in southern England, in which vegetation dynamics have been monitored for over 30 years. Decreasing fragment size was found to be associated with a decrease in biodiversity and recreational values, but an increase in relative carbon storage, aesthetic value and timber value. The trade-off between either biodiversity or recreational values with the other ecosystem services therefore became more pronounced as heathland size decreased. This was attributed to a higher rate of woody succession in smaller heathland fragments over the past three decades, and contrasting values of different successional vegetation types for biodiversity and provision of ecosystem services. These results suggest that habitat fragmentation can reduce the potential for developing "win win" solutions that contribute to biodiversity conservation while also supporting socio-economic development. Approaches to multi-purpose management of fragmented landscapes should therefore consider the potential trade-offs in ecosystem services and biodiversity associated with fragmentation, in order to make an effective contribution to sustainable development.
Cordingley, Justine E.; Newton, Adrian C.; Rose, Robert J.; Clarke, Ralph T.; Bullock, James M.
2015-01-01
While habitat fragmentation represents a major threat to global biodiversity, its impacts on provision of ecosystem services are largely unknown. We analysed biodiversity value and provision of multiple ecosystem services in 110 fragments of lowland heathland ecosystems in southern England, in which vegetation dynamics have been monitored for over 30 years. Decreasing fragment size was found to be associated with a decrease in biodiversity and recreational values, but an increase in relative carbon storage, aesthetic value and timber value. The trade-off between either biodiversity or recreational values with the other ecosystem services therefore became more pronounced as heathland size decreased. This was attributed to a higher rate of woody succession in smaller heathland fragments over the past three decades, and contrasting values of different successional vegetation types for biodiversity and provision of ecosystem services. These results suggest that habitat fragmentation can reduce the potential for developing “win win” solutions that contribute to biodiversity conservation while also supporting socio-economic development. Approaches to multi-purpose management of fragmented landscapes should therefore consider the potential trade-offs in ecosystem services and biodiversity associated with fragmentation, in order to make an effective contribution to sustainable development. PMID:26114753
Subashi, Ergys; Choudhury, Kingshuk R; Johnson, G Allan
2014-03-01
The pharmacokinetic parameters derived from dynamic contrast-enhanced (DCE) MRI have been used in more than 100 phase I trials and investigator led studies. A comparison of the absolute values of these quantities requires an estimation of their respective probability distribution function (PDF). The statistical variation of the DCE-MRI measurement is analyzed by considering the fundamental sources of error in the MR signal intensity acquired with the spoiled gradient-echo (SPGR) pulse sequence. The variance in the SPGR signal intensity arises from quadrature detection and excitation flip angle inconsistency. The noise power was measured in 11 phantoms of contrast agent concentration in the range [0-1] mM (in steps of 0.1 mM) and in onein vivo acquisition of a tumor-bearing mouse. The distribution of the flip angle was determined in a uniform 10 mM CuSO4 phantom using the spin echo double angle method. The PDF of a wide range of T1 values measured with the varying flip angle (VFA) technique was estimated through numerical simulations of the SPGR equation. The resultant uncertainty in contrast agent concentration was incorporated in the most common model of tracer exchange kinetics and the PDF of the derived pharmacokinetic parameters was studied numerically. The VFA method is an unbiased technique for measuringT1 only in the absence of bias in excitation flip angle. The time-dependent concentration of the contrast agent measured in vivo is within the theoretically predicted uncertainty. The uncertainty in measuring K(trans) with SPGR pulse sequences is of the same order, but always higher than, the uncertainty in measuring the pre-injection longitudinal relaxation time (T10). The lowest achievable bias/uncertainty in estimating this parameter is approximately 20%-70% higher than the bias/uncertainty in the measurement of the pre-injection T1 map. The fractional volume parameters derived from the extended Tofts model were found to be extremely sensitive to the variance in signal intensity. The SNR of the pre-injection T1 map indicates the limiting precision with which K(trans) can be calculated. Current small-animal imaging systems and pulse sequences robust to motion artifacts have the capacity for reproducible quantitative acquisitions with DCE-MRI. In these circumstances, it is feasible to achieve a level of precision limited only by physiologic variability.
Nauer, Claude Bertrand; Zubler, Christoph; Weisstanner, Christian; Stieger, Christof; Senn, Pascal; Arnold, Andreas
2012-03-01
The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80 kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3 mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = -0.94/-0.88) and was highest at 80 kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80 kV. However, image quality improvement was most relevant for low-dose scans. Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80 kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocols.
The effect of chromatic and luminance information on reaction times.
O'Donell, Beatriz M; Barraza, Jose F; Colombo, Elisa M
2010-07-01
We present a series of experiments exploring the effect of chromaticity on reaction time (RT) for a variety of stimulus conditions, including chromatic and luminance contrast, luminance, and size. The chromaticity of these stimuli was varied along a series of vectors in color space that included the two chromatic-opponent-cone axes, a red-green (L-M) axis and a blue-yellow [S - (L + M)] axis, and intermediate noncardinal orientations, as well as the luminance axis (L + M). For Weber luminance contrasts above 10-20%, RTs tend to the same asymptote, irrespective of chromatic direction. At lower luminance contrast, the addition of chromatic information shortens the RT. RTs are strongly influenced by stimulus size when the chromatic stimulus is modulated along the [S - (L + M)] pathway and by stimulus size and adaptation luminance for the (L-M) pathway. RTs are independent of stimulus size for stimuli larger than 0.5 deg. Data are modeled with a modified version of Pieron's formula with an exponent close to 2, in which the stimulus intensity term is replaced by a factor that considers the relative effects of chromatic and achromatic information, as indexed by the RMS (square-root of the cone contrast) value at isoluminance and the Weber luminance contrast, respectively. The parameters of the model reveal how RT is linked to stimulus size, chromatic channels, and adaptation luminance and how they can be interpreted in terms of two chromatic mechanisms. This equation predicts that, for isoluminance, RTs for a stimulus lying on the S-cone pathway are higher than those for a stimulus lying on the L-M-cone pathway, for a given RMS cone contrast. The equation also predicts an asymptotic trend to the RT for an achromatic stimulus when the luminance contrast is sufficiently large.
Bagshaw, Sean M; Ghali, William A
2004-01-01
Background Contrast-induced nephropathy is an important cause of acute renal failure. We assess the efficacy of acetylcysteine for prevention of contrast-induced nephropathy among patients undergoing intravascular angiography. Methods We conducted a systematic review and meta-analysis of randomized controlled trials comparing prophylactic acetylcysteine plus hydration versus hydration alone in patients undergoing intravascular angiography. Studies were identified by searching MEDLINE, EMBASE, and CENTRAL databases. Our main outcome measures were the risk of contrast-induced nephropathy and the difference in serum creatinine between acetylcysteine and control groups at 48 h. Results Fourteen studies involving 1261 patients were identified and included for analysis, and findings were heterogeneous across studies. Acetylcysteine was associated with a significantly reduced incidence of contrast-induced nephropathy in five studies, and no difference in the other nine (with a trend toward a higher incidence in six of the latter studies). The pooled odds ratio for contrast-induced nephropathy with acetylcysteine relative to control was 0.54 (95% CI, 0.32–0.91, p = 0.02) and the pooled estimate of difference in 48-h serum creatinine for acetylcysteine relative to control was -7.2 μmol/L (95% CI -19.7 to 5.3, p = 0.26). These pooled values need to be interpreted cautiously because of the heterogeneity across studies, and due to evidence of publication bias. Meta-regression suggested that the heterogeneity might be partially explained by whether the angiography was performed electively or as emergency. Conclusion These findings indicate that published studies of acetylcysteine for prevention of contrast-induced nephropathy yield inconsistent results. The efficacy of acetylcysteine will remain uncertain unless a large well-designed multi-center trial is performed. PMID:15500690
FLAIR*: A Combined MR Contrast Technique for Visualizing White Matter Lesions and Parenchymal Veins
George, Ilena C.; Shea, Colin D.; Gaitán, María I.; Reich, Daniel S.
2012-01-01
Purpose: To evaluate a magnetic resonance (MR) imaging contrast technique, called FLAIR*, that combines the advantages of T2-weighted fluid-attenuated inversion recovery (FLAIR) contrast and T2*-weighted contrast on a single image for assessment of white matter (WM) diseases such as multiple sclerosis (MS). Materials and Methods: This prospective pilot study was HIPAA compliant and institutional review board approved. Ten patients with clinically definite MS (eight men, two women; mean age, 41 years) provided informed consent and underwent 3.0-T MR imaging. Images from a T2-weighted FLAIR sequence were combined with images from a T2*-weighted segmented echo-planar imaging sequence performed during contrast material injection, yielding high-isotropic-resolution (0.55 × 0.55 × 0.55 mm3) FLAIR* images. Qualitative assessment was performed for image quality, lesion conspicuity, and vein conspicuity. Contrast-to-noise ratio (CNR) was calculated to compare normal-appearing WM (NAWM) with cerebrospinal fluid, lesions, and veins. To evaluate the differences in CNR among imaging modalities, a bootstrap procedure clustered on subjects was used, together with paired t tests. Results: High-quality FLAIR* images of the brain were produced at 3.0 T, yielding conspicuous lesions and veins. Lesion-to-NAWM and NAWM-to-vein CNR values were significantly higher for FLAIR* images than for T2-weighted FLAIR images (P < .0001). Findings on FLAIR* images included intralesional veins for lesions located throughout the brain and a hypointense rim around some WM lesions. Conclusion: High-isotropic-resolution FLAIR* images obtained at 3.0 T yield high contrast for WM lesions and parenchymal veins, making it well suited to investigate the relationship between WM abnormalities and veins in a clinical setting. © RSNA, 2012 PMID:23074257
Wang, Yong-Mei; Fan, Wei; Zhang, Kai; Zhang, Li; Tan, Zhen; Ma, Rong
2016-07-01
To explore the effectiveness of different transducers in breast contrast-enhanced ultrasound (CEUS) using SonoVue(®) (Bracco, Plan-Les-Ouates, Switzerland) as the contrast agent. Breast CEUS was performed in 51 patients with 51 breast lesions using a low-frequency transducer (probe C5-1) and a high-frequency transducer (probe L12-5) separately. All image processes were reviewed for the presence of local blood perfusion defects and surrounding vessels. McNemar's test was conducted to compare the detection effectiveness between these two transducers. Pathological results revealed 38 malignant and 13 benign lesions. The two transducers showed no difference in detecting benign lesions. Among malignant lesions, CEUS conducted by probe C5-1 (frequency range from 1 to 5 MHz) presented 23 (60.5%) lesions with local blood perfusion defects and 26 (68.4%) lesions with surrounding vessels. Meanwhile, probe L12-5 (frequency range from 5 to 12 MHz) showed only 12 (31.6%) lesions with local blood perfusion defects and 12 (31.6%) lesions with surrounding vessel. Probe C5-1 was more sensitive than probe L12-5 in detecting malignant CEUS characteristics (p-value < 0.05). The low-frequency transducer was more sensitive than the high-frequency transducer in breast CEUS using SonoVue as the contrast agent. A new contrast agent with a higher resonance frequency, specially designed for high-frequency transducers, may be helpful in improving the clinical value of breast CEUS. The first study comparing different frequency transducers in breast CEUS of the same patient lesions. We brought out the requirement for CEUS contrast agents which are more suitable for high-frequency examinations.
The impact of injector-based contrast agent administration in time-resolved MRA.
Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor
2018-05-01
Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.
The transmembrane gradient of the dielectric constant influences the DPH lifetime distribution.
Konopásek, I; Kvasnicka, P; Amler, E; Kotyk, A; Curatola, G
1995-11-06
The fluorescence lifetime distribution of 1,6-diphenyl-1,3,5-hexatriene (DPH) and 1-[4-(trimethylamino)phenyl]-6-phenyl-1,3,5-hexatriene (TMA-DPH) in egg-phosphatidylcholine liposomes was measured in normal and heavy water. The lower dielectric constant (by approximately 12%) of heavy water compared with normal water was employed to provide direct evidence that the drop of the dielectric constant along the membrane normal shifts the centers of the distribution of both DPH and TMA-DPH to higher values and sharpens the widths of the distribution. The profile of the dielectric constant along the membrane normal was not found to be a linear gradient (in contrast to [1]) but a more complex function. Presence of cholesterol in liposomes further shifted the center of the distributions to higher value and sharpened them. In addition, it resulted in a more gradient-like profile of the dielectric constant (i.e. linearization) along the normal of the membrane. The effect of the change of dielectric constant on the membrane proteins is discussed.
Contrast and autoshaping in multiple schedules varying reinforcer rate and duration.
Hamilton, B E; Silberberg, A
1978-07-01
Thirteen master pigeons were exposed to multiple schedules in which reinforcement frequency (Experiment I) or duration (Experiment II) was varied. In Phases 1 and 3 of Experiment I, the values of the first and second components' random-interval schedules were 33 and 99 seconds, respectively. In Phase 2, these values were 99 seconds for both components. In Experiment II, a random-interval 33-second schedule was associated with each component. During Phases 1 and 3, the first and second components had hopper durations of 7.5 and 2.5 seconds respectively. During Phase 2, both components' hopper durations were 2.5 seconds. In each experiment, positive contrast obtained for about half the master subjects. The rest showed a rate increase in both components (positive induction). Each master subject's key colors and reinforcers were synchronously presented on a response-independent basis to a yoked control. Richer component key-pecking occurred during each experiment's Phases 1 and 3 among half these subjects. However, none responded during the contrast condition (unchanged component of each experiment's Phase 2). From this it is inferred that autoshaping did not contribute to the contrast and induction findings among master birds. Little evidence of local contrast (highest rate at beginning of richer component) was found in any subject. These data show that (a) contrast can occur independently from autoshaping, (b) contrast assays during equal-valued components may produce induction, (c) local contrast in multiple schedules often does not occur, and (d) differential hopper durations can produce autoshaping and contrast.
Dembélé, Urbain; Lykke, Anne Mette; Koné, Yénizié; Témé, Bino; Kouyaté, Amadou Malé
2015-03-02
Carapa procera is a native oil tree species with multipurpose values traditionally exploited by the local population in Southern Mali. This study focused on the assessment of local knowledge about the use of Carapa procera. Semi-structured ethnobotanical questionnaires were conducted among the ethnic groups Senufo, Fulani and Bambara in two localities in the Sudanian zone in Mali. Use values among these ethnic groups and gender were evaluated. This study showed that Carapa procera is a species with multiple uses and high use values. According to the consensus value for plant parts (CPP), the nuts constituted 57% of exploited plant parts followed by bark and leaves (12%), wood and roots (7%), mistletoes (4%) and gum (1%). The use diversity (UD) values of Carapa procera showed a high proportion of cosmetic (UD = 0.49) and therapeutic (UD = 0.36) uses. The UD for therapeutic uses was higher for ethnic groups in Ziékorodougou than in Niankorobougou. In contrast, the UD for cosmetic uses was higher for ethnic groups in Niankorobougou than in Ziékorodougou. Comparative analysis between ethnic groups revealed that the highest UD for cosmetic uses (0.63) was observed in the Bambara ethnic group, whereas the highest UD for therapeutic uses (0.39) was obtained in the Senufo ethnic group. The UD showed that cosmetic uses were higher for women than for men in both locations. Men in Ziékorodougou had the highest level of knowledge regarding plant parts used, forms of use and the specific reasons for using Carapa procera. This study highlighted the sociocultural importance of Carapa procera. In the light of its multipurpose uses, the promotion and enhancement of Carapa procera can provide significant socio-economic benefits to local people. In this perspective, it is necessary to implement conservation strategies and sustainable management through domestication of the species.
Lasnon, Charline; Quak, Elske; Briand, Mélanie; Gu, Zheng; Louis, Marie-Hélène; Aide, Nicolas
2013-01-17
The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Firstly, a NEMA NU 4-2008 phantom (filled with 18F-FDG or 18F-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with 18F-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with 18F-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r2 = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and UEPET/CT quantitative values (r2 = 0.99, P < 0.0001). Receiver operating characteristic analysis demonstrated better diagnostic accuracy of CEPET/CT versus UEPET/CT (senior researcher, area under the curve (AUC) 0.96 versus 0.77, P = 0.004; junior researcher, AUC 0.78 versus 0.58, P = 0.004). The use of iodinated contrast media for small-animal PET imaging significantly improves tumor delineation and diagnostic performance, without significant alteration of SA-PET quantitative accuracy and NEMA NU 4-2008 IQ parameters.
NASA Astrophysics Data System (ADS)
Ramos, Jaime A.; Isabel Fagundes, Ana; Xavier, José C.; Fidalgo, Vera; Ceia, Filipe R.; Medeiros, Renata; Paiva, Vitor H.
2015-10-01
Changes in oceanographic conditions, shaped by changes in large-scale atmospheric phenomena such as the North Atlantic Oscillation (NAO), alters the structure and functioning of marine ecosystems. Such signals are readily captured by marine top predators, given that their use of foraging habitats and diets change when the NAO changes. In this study we assessed sexual, seasonal and annual (2010/11-2012/13) differences in diet, trophic and isotopic niche (using δ15N and δ13C values of whole blood, 1st primary, 8th secondary and breast feathers), foraging locations and oceanographic variation within foraging areas for Macaronesian shearwaters' (Puffinus baroli) during two years of contrasting NAO values, and between two sub-tropical islands 330 km apart in the North Atlantic Ocean, Cima Islet and Selvagem Grande. These two locations provide contrasting oceanographic foraging regimes for the birds, because the second colony is much closer to the African coast (375 vs 650 km), and, therefore, to the upwelling area of the Canary Current. There was a marked environmental perturbation in 2010/2011, related with a negative NAO Index and lower marine productivity (lower concentration of Chlorophyll a). This event corresponded to the Macaronesian shearwaters feeding farther north and west, which was readily seen in change of both δ15N and δ13C values, and in a higher intake of cephalopods. Diet and stable isotopes did not differ between sexes. Regurgitation analysis indicate a dominance of cephalopods in both islands, but prey fish were important for Selvagem Grande in 2012 and cephalopods for Cima Islet in 2011. Both δ15N and δ13C values were significantly higher for Cima Islet than for Selvagem Grande, irrespective of year, season and tissue sampled. SIBER analysis showed smaller isotopic niches for the breeding period. Our study suggests that during years of poor environmental conditions Macaronesian shearwaters shift their foraging location to more pelagic waters, take more cephalopods and overall present a narrower isotopic niche.
21 CFR 610.62 - Proper name; package label; legible type.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.62 Proper name; package... contrast in color value between the proper name and the background shall be at least as great as the color value between the trademark and trade name and the background. Typography, layout, contrast, and other...
Kim, Tae-Whan; Lee, Sang-Cheol; Kil, Se-Kee; Kang, Sung-Chul; Lim, Young-Tae; Kim, Ki-Tae; Panday, Siddhartha Bikram
2017-05-01
The purpose of the study was to investigate the effect of different kicking modality, i.e., erratic-dynamic target (EDT) versus static target (ST) on the performance of the roundhouse kick in two groups of taekwondo athletes of different skill level. Three-dimensional analysis and surface electromyography (SEMG) analysis were performed on 12 (Group A: six sub-elite, Group B: six elite) athletes to investigate muscle co-activation pattern under two conditions, i.e., EDT versus ST. In the results, the muscle recruitment ratio of the agonistic muscles was higher for Group A, whereas Group B had higher recruitment ratio for antagonist muscles. Overall, the co-activation index (CI) of hip joints appeared higher in the extensors for Group A, whereas higher CI was observed in flexor muscles for Group B with comparatively higher CI during EDT condition than ST condition. Higher value of CI was observed in flexor muscles of the knee joints among Group A during EDT conditions, in contrast, higher CI in the extensor muscles was observed among Group B during ST conditions. In conclusion, the study confirmed that erratic-dynamic movements of target could change the movement coordination pattern to maintain the joint stability of participants.
S-Shaped Suppression of the Superconducting Transition Temperature in Cu-Intercalated NbSe 2
Luo, Huixia; Strychalska-Nowak, Judyta; Li, Jun; ...
2017-03-21
2H-NbSe 2 is the prototype and most frequently studied of the well-known transition metal dichalcogenide (TMDC) superconductors. As 2H-NbSe 2 is widely acknowledged as a conventional superconductor, its transition temperature to the superconducting state (T c) is 7.3 K, a T c that is substantially higher than those seen for the majority of TMDCs, where Tc values between 2 and 4 K are the norm. We report the intercalation of Cu into 2H-NbSe 2 to make Cu xNbSe 2. As is typically found when chemically altering an optimal superconductor, T c decreases with an increase in x, but the waymore » that Tc is suppressed in this case is unusual: an S-shaped character is observed, with an inflection point near x = 0.03 and, at higher x values, a leveling off of the T c near 3 K, down to the usual value for a layered TMDC. Electronic characterization reveals corresponding S-like behavior for many of the parameters of the materials that influence T c. In order to illustrate its character, the superconducting phase diagram for Cu xNbSe 2 is contrasted with those of FexNbSe 2 and NbSe 2–xS x.« less
Eating style in seasonal affective disorder: who will gain weight in winter?
Kräuchi, K; Reich, S; Wirz-Justice, A
1997-01-01
Patients with seasonal affective disorder (SAD) selectively eat more carbohydrates (CHO), particularly sweets but also starch-rich foods, during their depression in winter. The Dutch Eating Behaviour Questionnaire (DEBQ) was administered to female SAD patients, healthy female controls, and female medical students to determine their eating style, together with the modified Seasonal Pattern Assessment Questionnaire (SPAQ+). SAD patients showed higher values for "emotional" (EMOT) eating than the students, and these in turn had higher values than the controls. In comparison to controls, SAD patients and students head high values for the factor "external" (EXT) eating, but there was no difference between the groups with respect to "restraint" (REST) eating. This is in strong contrast to patients with bulimia and anorexia nervosa, who are high REST eaters, indicating that SAD patients do not have a similar eating disorder. Additional items showed that SAD patients selectively eat sweets under emotionally difficult conditions (when depressed, anxious, or lonely). Configural frequency analysis showed that seasonal body weight change (SBWC) is high in subjects with high EMOT and REST eating together with a high body mass index (BMI). This result is in accordance with the concept of disinhibition of dietary restraint in extreme emotional situations, e.g., the depressive state.
Nissensohn, Mariela; Fuentes Lugo, Daniel; Serra-Majem, Lluis
2016-07-13
Recommendations of adequate total water intake (aTWI) have been proposed by the European Food Safety Agency (EFSA) and the Institute of Medicine (IOM)of the United States of America. However, there are differences in the approach used to support them: IOM recommendation is based on average intakes observed in NHANES III (Third National Health and Nutrition Examination Survey) and EFSA recommendation on a combination of observed intakes from 13 different European countries. Despite these recommendations of aTWI, the currently available scientifi c evidence is not sufficient to establish a cut-off value that would prevent disease, reduce the risk for chronic diseases or improve health status. To compare the average daily consumption of fluids (water and other beverages) in selective samples of population from Mexico, US and Spain, evaluating the quantity of fluid intake and understanding the contribution of each fluid type to the total fl uid intake. We also aim to determine if they reached adequate intake (AI) values, as defi ned by three different criteria: IOM, EFSA and water density. Three studies were compared: from Mexico, the National Health and Nutrition Survey conducted in 2012 (NHNS 2012); from US, the NHANES III 2005-2010 and from Spain the ANIBES study leaded in 2013. Different categories of beverages were used to establish the pattern of energy intake for each country. Only adult population was selected. TWI of each study was compared with EFSA and IOM AI recommendations, as well as applying the criterion of water density (mL/kcal). The American study obtained the higher value of total kcal/day from food and beverages (2,437 ± 13). Furthermore, the percentage of daily energy intake coming from beverages was, for American adults, 21%. Mexico was slightly behind with 19% and Spain ANIBES study registered only 12%. ANIBES showed signifi cantly low AI values for the overall population, but even more alarming in the case of males. Only 12% of men, in contrast with 21% of women, do satisfy the EFSA criterion. The IOM criterion reaches even less with higher recommended values for daily intake. In contrast, 60% of the American population reached the recommended intake of the IOM criterion. However, available data did not allow calculating the percentage reached by the EFSA criterion. Data from the Mexican study did not permit conducting comparisons with IOM or with EFSA. However, the water density criteria (mL/kcal) was higher than 1. There is a notable difference between all three populations in terms of TWI. Furthermore, within the same population, values of adequacy of TWI changed signifi cantly when they were assessed using different criteria. More scientifi c evidence is required for the production of better defined water intake recommendations in the future as well as more studies focusing on beverage consumption patterns in different settings.
Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.
2013-01-01
Purpose: To quantify the affinity of a cationic computed tomography (CT) contrast agent (CA4+) and that of an anionic contrast agent (ioxaglate) to glycosaminoglycans (GAGs) in ex vivo cartilage tissue explants and to characterize the in vivo diffusion kinetics of CA4+ and ioxaglate in a rabbit model. Materials and Methods: All in vivo procedures were approved by the institutional animal care and use committee. The affinities of ioxaglate and CA4+ to GAGs in cartilage (six bovine osteochondral plugs) were quantified by means of a modified binding assay using micro-CT after plug equilibration in serial dilutions of each agent. The contrast agents were administered intraarticularly to the knee joints of five New Zealand white rabbits to determine the in vivo diffusion kinetics and cartilage tissue imaging capabilities. Kinetics of diffusion into the femoral groove cartilage and relative contrast agent uptake into bovine plugs were characterized by means of nonlinear mixed-effects models. Diffusion time constants (τ) were compared by using a Student t test. Results: The uptake of CA4+ in cartilage was consistently over 100% of the reservoir concentration, whereas it was only 59% for ioxaglate. In vivo, the contrast material–enhanced cartilage reached a steady CT attenuation for both CA4+ and ioxaglate, with τ values of 13.8 and 6.5 minutes, respectively (P = .04). The cartilage was easily distinguishable from the surrounding tissues for CA4+ (12 mg of iodine per milliliter); comparatively, the anionic contrast agent provided less favorable imaging results, even when a higher concentration was used (80 mg of iodine per milliliter). Conclusion: The affinity of the cationic contrast agent CA4+ to GAGs enables high-quality imaging and segmentation of ex vivo bovine and rabbit cartilage, as well as in vivo rabbit cartilage. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112246/-/DC1 PMID:23192774
Wang, Zhen J.; Chen, Katherine S.; Gould, Robert; Coakley, Fergus V.; Fu, Yanjun; Yeh, Benjamin M.
2014-01-01
Objective To assess the effect of positive enteric contrast administration on automatic exposure control (AEC) CT radiation exposure in 1) a CT phantom, and 2) a retrospective review of patients. Materials and Methods We scanned a CT phantom containing simulated bowel that was sequentially filled with water and positive enteric contrast, and recorded the mean volume CT dose index (CTDIvol). We also identified 17 patients who had undergone 2 technically comparable CT scans of the abdomen and pelvis, one with positive enteric contrast and the other with oral water. Paired student t-tests were used to compare the mean CTDIvol between scans performed with and without positive enteric contrast. Both the phantom and patient CT scans were performed using AEC with a fixed noise index. Results The mean CTDIvol for the phantom with simulated bowel containing water and positive enteric contrast were 8.2 ± 0.2 mGy, and 8.7 ± 0.1 mGy (6.1% higher than water, p=0.02), respectively. The mean CTDIvol for patients scanned with oral water and with positive enteric contrast were 11.8mGy and 13.1mGy, respectively (p=0.003). This corresponded to a mean CTDIvol which was 11.0% higher (range: 0.0–20.7% higher) in scans with positive enteric contrast than those with oral water in patients. Conclusions When automatic exposure control is utilized for abdominopelvic CT, the radiation exposure, as measured by CTDIvol, is higher for scans performed with positive enteric contrast than those with oral water. PMID:21493028
Durkovic, Jaroslav; Canová, Ingrid; Lagana, Rastislav; Kucerová, Veronika; Moravcík, Michal; Priwitzer, Tibor; Urban, Josef; Dvorák, Milon; Krajnáková, Jana
2013-02-01
Previous studies have shown that Ophiostoma novo-ulmi, the causative agent of Dutch elm disease (DED), is able to colonize remote areas in infected plants of Ulmus such as the leaf midrib and secondary veins. The objective of this study was to compare the performances in leaf traits between two Dutch elm hybrids 'Groeneveld' and 'Dodoens' which possess a contrasting tolerance to DED. Trait linkages were also tested with leaf mass per area (LMA) and with the reduced Young's modulus of elasticity (MOE) as a result of structural, developmental or functional linkages. Measurements and comparisons were made of leaf growth traits, primary xylem density components, gas exchange variables and chlorophyll a fluorescence yields between mature plants of 'Groeneveld' and 'Dodoens' grown under field conditions. A recently developed atomic force microscopy technique, PeakForce quantitative nanomechanical mapping, was used to reveal nanomechanical properties of the cell walls of tracheary elements such as MOE, adhesion and dissipation. 'Dodoens' had significantly higher values for LMA, leaf tissue thickness variables, tracheary element lumen area (A), relative hydraulic conductivity (RC), gas exchange variables and chlorophyll a fluorescence yields. 'Groeneveld' had stiffer cell walls of tracheary elements, and higher values for water-use efficiency and leaf water potential. Leaves with a large carbon and nutrient investment in LMA tended to have a greater leaf thickness and a higher net photosynthetic rate, but LMA was independent of RC. Significant linkages were also found between the MOE and some vascular traits such as RC, A and the number of tracheary elements per unit area. Strong dissimilarities in leaf trait performances were observed between the examined Dutch elm hybrids. Both hybrids were clearly separated from each other in the multivariate leaf trait space. Leaf growth, vascular and gas exchange traits in the infected plants of 'Dodoens' were unaffected by the DED fungus. 'Dodoens' proved to be a valuable elm germplasm for further breeding strategies.
Dynamic contrast enhanced MRI of the prostate: comparison of gadobutrol and Gd-DTPA.
Durmus, T; Vollnberg, B; Schwenke, C; Kilic, E; Huppertz, A; Taupitz, M; Franiel, T
2013-09-01
To evaluate the enhancement profile of the macrocyclic contrast medium (CM) gadobutrol in comparison to linear CM Gd-DTPA in DCE-MRI of the prostate. In total 53 patients with prostata cancer (PCa) were included, who received a radical prostatectomy after multiparametric MRI of the prostate including DCE-MRI. Using circular regions of interests normal peripheral zone (PZ) and PCa foci > 5 mm in diameter (42 and 34 foci in Gd-DTPA and gadobutrol group, respectively) were analysed in DCE-MRI. Enhancement curves (Type I, II and III) and pharmacokinetic parameters were analyzed qualitatively and quantitatively and compared using mixed linear models (two sided p-values < 0.05 were regarded significant). There was no significant difference in frequencies of curve types I, II or III in the normal PZ (p = 0.63) or in PCa foci (p = 0.75). PCa with a Gleason score ≥ 7 had in comparison to Gleason ≤ 6 significantly more often a Wash-Out-curve (Type III) with both CM (p = 0.02). The relative peak enhancement was in the PZ (Gd-DTPA 1.4 a. u. [1.20; 1.59], gadobutrol 1.58 a. u. [1.37; 1.78]) and in PCa foci (Gd-DTPA 1.56 a. u. [1.41; 1.71], gadobutrol 1.76 a. u. [1.59; 1.94]) significantly higher with gadobutrol (p = 0.04). The pharmacokinetic parameters Ktrans und kep were higher in PCa foci than in PZ (p < 0.0001 and p = 0.002, respectively) without significant difference of the parameter values between both CM (p = 0.65). [corrected] This study is the first systematic comparison of gadobutrol and Gd-DTPA in DCE-MRI of the prostate. The relative peak enhancement is higher using gadobutrol compared to Gd-DTPA in DCE-MRI. There was no statistically significant difference in curve types or the pharmacokinetic parameters in PCa or normal PZ between both CM. © Georg Thieme Verlag KG Stuttgart · New York.
Liang, Jianye; Liu, Dexiang; Gao, Peng; Zhang, Dong; Chen, Hanwei; Shi, Changzheng; Luo, Liangping
2018-03-01
This study aimed to collect the studies on the role of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and dynamic susceptibility contrast MRI (DSC-MRI) in differentiating the grades of gliomas, and evaluate the diagnostic performances of relevant quantitative parameters in glioma grading. We systematically searched studies on the diagnosis of gliomas with DCE-MRI or DSC-MRI in Medline, PubMed, China National Knowledge Infrastructure database, Cochrane Library, and Embase published between January 2005 and December 2016. Standardized mean differences and 95% confidence intervals were calculated for volume transfer coefficient (K trans ), volume fraction of extravascular extracellular space (V e ), rate constant of backflux (K ep ), relative cerebral blood volume (rCBV), and relative cerebral blood flow (rCBF) using Review Manager 5.2 software. Sensitivity, specificity, area under the curve (AUC), and Begg test were calculated by Stata 12.0. Twenty-two studies with available outcome data were included in the analysis. The standardized mean difference of K trans values between high-grade glioma and low-grade glioma were 1.18 (0.91, 1.45); V e values were 1.43 (1.06, 1.80); K ep values were 0.65 (-0.05, 1.36); rCBV values were 1.44 (1.08, 1.81); and rCBF values were 1.17 (0.68, 1.67), respectively. The results were all significant statistically (P < .05) except K ep values (P = .07), and high-grade glioma had higher K trans , V e , rCBV, and rCBF values than low-grade glioma. AUC values of K trans , V e , rCBV, and rCBF were 0.90, 0.88, 0.93, and 0.73, respectively; rCBV had the largest AUC among the four parameters (P < .05). Both DCE-MRI and DSC-MRI are reliable techniques in differentiating the grades of gliomas, and rCBV was found to be the most sensitive one. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Rudebeck, Peter H.; Murray, Elisabeth A.
2014-01-01
The primate orbitofrontal cortex (OFC) is often treated as a single entity, but architectonic and connectional neuroanatomy indicates that it has distinguishable parts. Nevertheless, few studies have attempted to dissociate the functions of its subregions. Here we review findings from recent neuropsychological and neurophysiological studies that do so. The lateral OFC seems to be important for learning, representing and updating specific object–reward associations. Medial OFC seems to be important for value comparisons and choosing among objects on that basis. Rather than viewing this dissociation of function in terms of learning versus choosing, however, we suggest that it reflects the distinction between contrasts and comparisons: differences versus similarities. Making use of high-dimensional representations that arise from the convergence of several sensory modalities, the lateral OFC encodes contrasts among outcomes. The medial MFC reduces these contrasting representations of value to a single dimension, a common currency, in order to compare alternative choices. PMID:22145870
Cognitive dissonance in children: justification of effort or contrast?
Alessandri, Jérôme; Darcheville, Jean-Claude; Zentall, Thomas R
2008-06-01
Justification of effort is a form of cognitive dissonance in which the subjective value of an outcome is directly related to the effort that went into obtaining it. However, it is likely that in social contexts (such as the requirements for joining a group) an inference can be made (perhaps incorrectly) that an outcome that requires greater effort to obtain in fact has greater value. Here we present evidence that a cognitive dissonance effect can be found in children under conditions that offer better control for the social value of the outcome. This effect is quite similar to contrast effects that recently have been studied in animals. We suggest that contrast between the effort required to obtain the outcome and the outcome itself provides a more parsimonious account of this phenomenon and perhaps other related cognitive dissonance phenomena as well. Research will be needed to identify cognitive dissonance processes that are different from contrast effects of this kind.
Authoritarianism, religious fundamentalism, and the human prefrontal cortex
Asp, Erik; Ramchandran, Kanchna; Tranel, Daniel
2012-01-01
Objective The psychological processes of doubting and skepticism have recently become topics of neuroscientific investigation. In this context, we developed the False Tagging Theory, a neurobiological model of the belief and doubt process, which proposes that the prefrontal cortex is critical for normative doubt regarding properly comprehended cognitive representations. Here, we put our theory to an empirical test, hypothesizing that patients with prefrontal cortex damage would have a doubt deficit that would manifest as higher authoritarianism and religious fundamentalism. Method Ten patients with bilateral damage to the ventromedial prefrontal cortex (vmPFC), ten patients with damage to areas outside the vmPFC, and sixteen medical comparison patients, who experienced life-threatening (but non-neurological) medical events, completed a series of scales measuring authoritarianism, religious fundamentalism, and specific religious beliefs. Results VMPFC patients reported significantly higher authoritarianism and religious fundamentalism than the other groups. The degrees of authoritarianism and religious fundamentalism in the vmPFC group were significantly higher than normative values, as well; by contrast, the comparison groups did not differ from normative values. Moreover, vmPFC patients reported increased specific religious beliefs after brain injury. Conclusions The findings support the False Tagging Theory, and suggest that the vmPFC is critical for psychological doubt and resistance to authoritarian persuasion. PMID:22612576
Innovations in diagnostic imaging of localized prostate cancer.
Pummer, Karl; Rieken, Malte; Augustin, Herbert; Gutschi, Thomas; Shariat, Shahrokh F
2014-08-01
In recent years, various imaging modalities have been developed to improve diagnosis, staging, and localization of early-stage prostate cancer (PCa). A MEDLINE literature search of the time frame between 01/2007 and 06/2013 was performed on imaging of localized PCa. Conventional transrectal ultrasound (TRUS) is mainly used to guide prostate biopsy. Contrast-enhanced ultrasound is based on the assumption that PCa tissue is hypervascularized and might be better identified after intravenous injection of a microbubble contrast agent. However, results on its additional value for cancer detection are controversial. Computer-based analysis of the transrectal ultrasound signal (C-TRUS) appears to detect cancer in a high rate of patients with previous biopsies. Real-time elastography seems to have higher sensitivity, specificity, and positive predictive value than conventional TRUS. However, the method still awaits prospective validation. The same is true for prostate histoscanning, an ultrasound-based method for tissue characterization. Currently, multiparametric MRI provides improved tissue visualization of the prostate, which may be helpful in the diagnosis and targeting of prostate lesions. However, most published series are small and suffer from variations in indication, methodology, quality, interpretation, and reporting. Among ultrasound-based techniques, real-time elastography and C-TRUS seem the most promising techniques. Multiparametric MRI appears to have advantages over conventional T2-weighted MRI in the detection of PCa. Despite these promising results, currently, no recommendation for the routine use of these novel imaging techniques can be made. Prospective studies defining the value of various imaging modalities are urgently needed.
Sorption behaviour of nonylphenol and nonylphenol monoethoxylate in soils.
Milinovic, J; Lacorte, S; Rigol, A; Vidal, M
2015-11-01
Sorption behaviour of two alkylphenolic compounds (APCs), nonylphenol (NP) and nonylphenol monoethoxylate (NP1EO), was studied in five soils with contrasting characteristics. Sorption isotherms were obtained by equilibrating the soil samples with 0.01 mol L(-1) CaCl2 solutions containing different initial concentrations of NP or NP1EO. Linear fitting was generally appropriate for describing the sorption behaviour of NP and NP1EO in the soils, with the exception of two cases, for which the Freundlich model was more suitable for describing the sorption pattern of NP1EO. Solid-liquid distribution coefficients derived from sorption isotherms (Kd) varied from 24 to 1059 mL g(-1) for NP and from 51 to 740 mL g(-1) for NP1EO. For most soils, sorption Kd values were higher for NP than for NP1EO due to the higher hydrophobicity of NP. Sorption reversibility of NP and NP1EO was also tested from desorption isotherms. Desorption solid-liquid distribution coefficients (Kd,des), obtained from linear fitting, were between 130 and 1467 mL g(-1) for NP and between 24 and 1285 mL g(-1) for NP1EO. Kd,des values were higher than Kd values, which demonstrated that target compounds were irreversibly sorbed into soils, with the exception of the high desorption yield (45%) of NP1EO in the soil with the lowest content of organic matter. The fraction of soil organic carbon (FOC) was a key parameter that influenced the sorption of NP and NP1EO in soils, with logKOC values of 4.0 and 3.8, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.
Abdominal MRI at 3.0 T: LAVA-Flex compared with conventional fat suppression T1-weighted images.
Li, Xing Hui; Zhu, Jiang; Zhang, Xiao Ming; Ji, Yi Fan; Chen, Tian Wu; Huang, Xiao Hua; Yang, Lin; Zeng, Nan Lin
2014-07-01
To study liver imaging with volume acceleration-flexible (LAVA-Flex) for abdominal magnetic resonance imaging (MRI) at 3.0 T and compare the image quality of abdominal organs between LAVA-Flex and fast spoiled gradient-recalled (FSPGR) T1-weighted imaging. Our Institutional Review Board approval was obtained in this retrospective study. Sixty-nine subjects had both FSPGR and LAVA-Flex sequences. Two radiologists independently scored the acquisitions for image quality, fat suppression quality, and artifacts and the values obtained were compared with the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, the contrast between muscle and fat and normal liver and liver lesions were compared by the paired t-test. The liver and spleen SI on the fat-only phase were analyzed in the fatty liver patients. Compared with FSPGR imaging, LAVA-Flex images had better and more homogenous fat suppression and lower susceptibility artifact (qualitative scores: 4.70 vs. 4.00, 4.86% vs. 7.14%, 4.60 and 4.10, respectively). The contrast between muscle and fat and between the liver and pathologic lesions was significantly improved on the LAVA-Flex sequence. The contrast value of the fatty liver and spleen was higher than that of the liver and spleen. The LAVA-Flex sequence offers superior and more homogenous fat suppression of the abdomen than does the FSPGR sequence. The fat-only phase can be a simple and effective method of assessing fatty liver. © 2013 Wiley Periodicals, Inc.
Radiation dose and image quality for paediatric interventional cardiology
NASA Astrophysics Data System (ADS)
Vano, E.; Ubeda, C.; Leyton, F.; Miranda, P.
2008-08-01
Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 µGy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 µGy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.
NASA Astrophysics Data System (ADS)
Zhao, Mingkang; Wi, Hun; Lee, Eun Jung; Woo, Eung Je; In Oh, Tong
2014-10-01
Electrical impedance imaging has the potential to detect an early stage of breast cancer due to higher admittivity values compared with those of normal breast tissues. The tumor size and extent of axillary lymph node involvement are important parameters to evaluate the breast cancer survival rate. Additionally, the anomaly characterization is required to distinguish a malignant tumor from a benign tumor. In order to overcome the limitation of breast cancer detection using impedance measurement probes, we developed the high density trans-admittance mammography (TAM) system with 60 × 60 electrode array and produced trans-admittance maps obtained at several frequency pairs. We applied the anomaly detection algorithm to the high density TAM system for estimating the volume and position of breast tumor. We tested four different sizes of anomaly with three different conductivity contrasts at four different depths. From multifrequency trans-admittance maps, we can readily observe the transversal position and estimate its volume and depth. Specially, the depth estimated values were obtained accurately, which were independent to the size and conductivity contrast when applying the new formula using Laplacian of trans-admittance map. The volume estimation was dependent on the conductivity contrast between anomaly and background in the breast phantom. We characterized two testing anomalies using frequency difference trans-admittance data to eliminate the dependency of anomaly position and size. We confirmed the anomaly detection and characterization algorithm with the high density TAM system on bovine breast tissue. Both results showed the feasibility of detecting the size and position of anomaly and tissue characterization for screening the breast cancer.
NASA Astrophysics Data System (ADS)
Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.
2017-08-01
Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.
Prospective Investigation of the Contrast Avoidance Model of Generalized Anxiety and Worry.
Crouch, Tara A; Lewis, Jamie A; Erickson, Thane M; Newman, Michelle G
2017-07-01
The factors that maintain generalized anxiety disorder (GAD) symptoms and worry over time are not entirely clear. The Contrast Avoidance Model (CAM) postulates that individuals at risk for pathological worry and GAD symptoms uniquely fear emotional shifts from neutral or positive emotions into negative emotional states, and consequently use worry to maintain negative emotion in order to avoid shifts or blunt the effect of negative contrasts. This model has received support in laboratory experiments, but has not been investigated prospectively in the naturalistic context of daily life. The present study tested the CAM in a longitudinal experience sampling study with a subclinical sample. Participants selected to represent a broad range of symptoms (N = 92) completed baseline measures of GAD and depression symptoms, and eight weekly assessments of worry, experiences of negative emotional contrasts during their worst event of the week, and situation-specific negative emotion. Consistent with the CAM, GAD symptoms prospectively predicted higher endorsement of negative contrast experiences as worst events, independent of depression symptoms. Unsurprisingly, higher negative contrasts predicted higher negative emotion. However, both higher baseline GAD symptoms and weekly worry uniquely moderated (reduced) this relationship, providing consistent support for the idea that worry may blunt the emotional effects of contrasts. Depression symptoms did not have the same moderating effect. These findings support the CAM in an ecologically valid context. Copyright © 2016. Published by Elsevier Ltd.
Comparing and Contrasting American and Japanese Cultural Values Using a Negotiation Continuum Model.
ERIC Educational Resources Information Center
Garrison, Jean A.
A negotiation continuum model can be used to compare and contrast American and Japanese cultural values. Although two basic styles of negotiating--competitive and cooperative--can be identified, there are a number of general principles that govern all negotiations. These include planning and preparing strategies in advance and practicing nonverbal…
Values and Objectivity in Science: Value-Ladenness, Pluralism and the Epistemic Attitude
ERIC Educational Resources Information Center
Carrier, Martin
2013-01-01
My intention is to cast light on the characteristics of epistemic or fundamental research (in contrast to application-oriented research). I contrast a Baconian notion of objectivity, expressing a correspondence of the views of scientists to the facts, with a pluralist notion, involving a critical debate between conflicting approaches. These…
Study of Lead as a Source X-ray Radiation Protection with an Analysis Grey Level Image
NASA Astrophysics Data System (ADS)
Susilo; Rahma, I. N.; Mosik; Masturi
2017-04-01
X-ray utilization in the medical field still has a potential danger for the human. This occurs when exposure to x-ray radiation received exceeds the dose limit value. It required a radiation shielding to prevent the hazard, and lead is one of the metals usually used as x-ray radiation shield. This work aims to determine the metallic lead properties to find out of the step wedge lead radiograph image. The instruments used are the plane x-ray, digital radiography system and personal computer installed by MATLAB, while the material is step wedge lead. The image of radiograph was analysed using GUI applications on MATLAB software to determine the values of grey level from the image and the optical density of the radiograph image. The results showed the greater optical density, the higher the image contrast, and the value of optical density in the image is inversely proportional to the voltage x-ray since the value of grey level at high voltage is smaller than that of at low voltage.
NASA Astrophysics Data System (ADS)
Shi, Shuai; Guo, Dan; Luo, Jianbin
2017-10-01
Active quality factor (Q) exhibits many promising properties in dynamic atomic force microscopy. Energy dissipation and image contrasts are investigated in the non-contact amplitude modulation atomic force microscopy (AM-AFM) with an active Q-control circuit in the ambient air environment. Dissipated power and virial were calculated to compare the highly nonlinear interaction of tip-sample and image contrasts with different Q gain values. Greater free amplitudes and lower effective Q values show better contrasts for the same setpoint ratio. Active quality factor also can be employed to change tip-sample interaction force in non-contact regime. It is meaningful that non-destructive and better contrast images can be realized in non-contact AM-AFM by applying an active Q-control to the dynamic system.
Toro-Farmer, Gerardo; Muller-Karger, Frank E.; Vega-Rodriguez, Maria; Melo, Nelson; Yates, Kimberly K.; Johns, Elizabeth; Cerdeira-Estrada, Sergio; Herwitz, Stan R.
2016-01-01
Light availability is an important factor driving primary productivity in benthic ecosystems, but in situ and remote sensing measurements of light quality are limited for coral reefs and seagrass beds. We evaluated the productivity responses of a patch reef and a seagrass site in the Lower Florida Keys to ambient light availability and spectral quality. In situ optical properties were characterized utilizing moored and water column bio-optical and hydrographic measurements. Net ecosystem productivity (NEP) was also estimated for these study sites using benthic productivity chambers. Our results show higher spectral light attenuation and absorption, and lower irradiance during low tide in the patch reef, tracking the influx of materials from shallower coastal areas. In contrast, the intrusion of clearer surface Atlantic Ocean water caused lower values of spectral attenuation and absorption, and higher irradiance in the patch reef during high tide. Storms during the studied period, with winds >10 m·s−1, caused higher spectral attenuation values. A spatial gradient of NEP was observed, from high productivity in the shallow seagrass area, to lower productivity in deeper patch reefs. The highest daytime NEP was observed in the seagrass, with values of almost 0.4 g·O2·m−2·h−1. Productivity at the patch reef area was lower in May than during October 2012 (mean = 0.137 and 0.177 g·O2·m−2·h−1, respectively). Higher photosynthetic active radiation (PAR) levels measured above water and lower light attenuation in the red region of the visible spectrum (~666 to ~699 nm) had a positive correlation with NEP. Our results indicate that changes in light availability and quality by suspended or resuspended particles limit benthic productivity in the Florida Keys.
Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.
Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu
2018-03-13
Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values of the knees in a rabbit OA model and a control model using a new double-contrast agent. MRI with this agent enabled OA detection earlier than using conventional MRI.
Martínez, Isabel; García, José Fernando
2008-01-01
The relation between parenting styles and adolescent outcomes was analyzed in a sample of 1,198 15-18-year-old Brazilians. The adolescents were classified into 1 of 4 groups (Authoritative, Authoritarian, Indulgent, and Neglectful) on the basis of their own ratings of their parents on two dimensions: Acceptance/ Involvement and Strictness/Imposition. The adolescents were then contrasted along two different outcomes: (1) priority given to Schwartz Self-transcendence and Conservation values, and (2) level of Self-esteem (appraised in 5 domains: Academic, Social, Emotional, Family, and Physical). Results showed that Authoritative and Indulgent parenting is associated with the highest internalization of Self-Transcendence and Conservation values of teenagers, whereas Authoritarian parenting is associated with the lowest. On the other hand, adolescents with Indulgent parents have equal or higher levels of Self-esteem than adolescents with Authoritative parents, while adolescents raised in Authoritarian and Neglectful homes have the lowest scores in Self-Esteem.
Carro, M D; Ranilla, M J; Martín-García, A I; Molina-Alcaide, E
2009-04-01
Eight Rusitec and eight single-flow continuous-culture fermenters (SFCCF) were used to compare the ruminal fermentation of two diets composed of alfalfa hay and concentrate in proportions of 80 : 20 (F80) and 20 : 80 (F20). Results were validated with those obtained previously in sheep fed the same diets. Rusitec fermenters were fed once daily and SFCCF twice, but liquid dilution rates were similar in both types of fermenters. Mean values of pH over the 12 h postfeeding were higher (P < 0.001) in Rusitec than in SFCCF, with diet F80 showing higher values (P < 0.001) in both types of fermenters. Concentrations of total volatile fatty acids (VFA) were higher (P < 0.001) in SFCCF than in Rusitec, and in both systems were higher (P = 0.002) for diet F20 than for diet F80. There were significant differences between systems in the proportions of the main VFA, and a fermentation system × diet interaction (P < 0.001) was detected for all VFA with the exception of valerate. No differences (P = 0.145) between the two types of fermenters were detected in dry matter (DM) digestibility, but NDF, microbial N flow and its efficiency were higher (P = 0.001) in SFCCF compared to Rusitec. Whereas pH values and VFA concentrations remained fairly stable through the day in both in vitro systems, pH dropped and VFA increased shortly after feeding in sheep rumen reaching the minimum and maximal values, respectively, about 4 h after feeding. Both in vitro systems detected differences between diets similar to those found in sheep for liquid dilution rate, pH values, DM digestibility, microbial N flow and growth efficiency. In contrast, acetate/propionate ratios were lower for diet F20 than for F80 in sheep rumen (2.73 and 3.97) and SFCCF (3.07 and 4.80), but were higher for diet F20 compared to F80 (4.29 and 3.40) in Rusitec, with values considered to be unphysiological for high-concentrate diets. In vivo NDF digestibility was affected (P = 0.017) by diet, but no differences between diets (P > 0.05) were found in any in vitro system. A more precise control of pH in both types of fermenters and a reduction of concentrate retention time in Rusitec could probably improve the simulation of in vivo fermentation.
NASA Astrophysics Data System (ADS)
Trull, T. W.; Davies, D. M.; Dehairs, F.; Cavagna, A.-J.; Lasbleiz, M.; Laurenceau-Cornec, E. C.; d'Ovidio, F.; Planchon, F.; Leblanc, K.; Quéguiner, B.; Blain, S.
2015-02-01
We examined phytoplankton community responses to natural iron fertilisation at 32 sites over and downstream from the Kerguelen Plateau in the Southern Ocean during the austral spring bloom in October-November 2011. The community structure was estimated from chemical and isotopic measurements (particulate organic carbon - POC; 13C-POC; particulate nitrogen - PN; 15N-PN; and biogenic silica - BSi) on size-fractionated samples from surface waters (300, 210, 50, 20, 5, and 1 μm fractions). Higher values of 13C-POC (vs. co-located 13C values for dissolved inorganic carbon - DIC) were taken as indicative of faster growth rates and higher values of 15N-PN (vs. co-located 15N-NO3 source values) as indicative of greater nitrate use (rather than ammonium use, i.e. higher f ratios). Community responses varied in relation to both regional circulation and the advance of the bloom. Iron-fertilised waters over the plateau developed dominance by very large diatoms (50-210 μm) with high BSi / POC ratios, high growth rates, and significant ammonium recycling (lower f ratios) as biomass built up. In contrast, downstream polar frontal waters with a similar or higher iron supply were dominated by smaller diatoms (20-50 μm) and exhibited greater ammonium recycling. Stations in a deep-water bathymetrically trapped recirculation south of the polar front with lower iron levels showed the large-cell dominance observed on the plateau but much less biomass. Comparison of these communities to surface water nitrate (and silicate) depletions as a proxy for export shows that the low-biomass recirculation feature had exported similar amounts of nitrogen to the high-biomass blooms over the plateau and north of the polar front. This suggests that early spring trophodynamic and export responses differed between regions with persistent low levels vs. intermittent high levels of iron fertilisation.
NASA Technical Reports Server (NTRS)
Thomas, H. H.
1984-01-01
A petrologic model of the northern Mississippi Embayment, derived from gravity, seismic and rift data, is evaluated by converting the model to a magnetization model which is compared with satellite magnetic anomaly models. A magnetization contrast of approximately -0.54 A/m, determined from the petrologic model of the embayment compares favorably to values of -0.62 A/m and -0.45 A/m from a Magsat United States Apparent Magnetization Contrast Map and a published POGO magnetization contrast model, respectively. The petrologic model suggests that the magnetic anomaly low associated with the Mississippi Embayment may be largely due to the intrusion under non-oxidizing conditions of low Curie temperature gabbroic material at the base of the crust of the embayment. Near-surface mafic plutons, bordering the Mississippi Valley Graben, appear from aeromagnetic data to have higher magnetizations than the deeper gabbroic material; however, it is impossible to ascertain if this is due to compositional differences or similar material at shallower (lower temperature) depths. These results indicate that variations in the Curie temperatures of intrusions accompanying rifting may account for a large part of the wide range of magnetic anomalies associated with presently inactive rifts with normal heat flow.
Pathak, Ashish K; Singh, Sudhir P; Gupta, Yogesh; Gurjar, Anoop K S; Mantri, Shrikant S; Tuli, Rakesh
2016-11-08
Litchi chinensis is a subtropical fruit crop, popular for its nutritional value and taste. Fruits with small seed size and thick aril are desirable in litchi. To gain molecular insight into gene expression that leads to the reduction in the size of seed in Litchi chinensis, transcriptomes of two genetically closely related genotypes, with contrasting seed size were compared in developing ovules. The cDNA library constructed from early developmental stages of ovules (0, 6, and 14 days after anthesis) of bold- and small-seeded litchi genotypes yielded 303,778,968 high quality paired-end reads. These were de-novo assembled into 1,19,939 transcripts with an average length of 865 bp. A total of 10,186 transcripts with contrast in expression were identified in developing ovules between the small- and large- seeded genotypes. A majority of these differences were present in ovules before anthesis, thus suggesting the role of maternal factors in seed development. A number of transcripts indicative of metabolic stress, expressed at higher level in the small seeded genotype. Several differentially expressed transcripts identified in such ovules showed homology with Arabidopsis genes associated with different stages of ovule development and embryogenesis.
Stewart, Jared J; Polutchko, Stephanie K; Demmig-Adams, Barbara; Adams, William W
2018-01-01
An Arabidopsis thaliana accession with naturally low vein density, Eifel-5 (Ei-5), was compared to Columbia-0 (Col-0) with respect to rosette growth, foliar vein architecture, photosynthesis, and transpiration. In addition to having to a lower vein density, Ei-5 grew more slowly, with significantly lower rates of rosette expansion, but had similar capacities for photosynthetic oxygen evolution on a leaf area basis compared to Col-0. The individual foliar minor veins were larger in Ei-5, with a greater number of vascular cells per vein, compared to Col-0. This compensation for low vein density resulted in similar values for the product of vein density × phloem cell number per minor vein in Ei-5 and Col-0, which suggests a similar capacity for foliar sugar export to support similar photosynthetic capacities per unit leaf area. In contrast, the product of vein density × xylem cell number per minor vein was significantly greater in Ei-5 compared to Col-0, and was associated not only with a higher ratio of water-transporting tracheary elements versus sugar-transporting sieve elements but also significantly higher foliar transpiration rates per leaf area in Ei-5. In contrast, previous studies in other systems had reported higher ratios of tracheary to sieve elements and higher transpiration rate to be associated with higher - rather than lower - vein densities. The Ei-5 accession thus further underscores the plasticity of the foliar vasculature by illustrating an example where a higher ratio of tracheary to sieve elements is associated with a lower vein density. Establishment of the Ei-5 accession, with a low vein density but an apparent overcapacity for water flux through the foliar xylem network, may have been facilitated by a higher level of precipitation in its habitat of origin compared to that of the Col-0 accession.
Contrast and autoshaping in multiple schedules varying reinforcer rate and duration
Hamilton, Bruce E.; Silberberg, Alan
1978-01-01
Thirteen master pigeons were exposed to multiple schedules in which reinforcement frequency (Experiment I) or duration (Experiment II) was varied. In Phases 1 and 3 of Experiment I, the values of the first and second components' random-interval schedules were 33 and 99 seconds, respectively. In Phase 2, these values were 99 seconds for both components. In Experiment II, a random-interval 33-second schedule was associated with each component. During Phases 1 and 3, the first and second components had hopper durations of 7.5 and 2.5 seconds respectively. During Phase 2, both components' hopper durations were 2.5 seconds. In each experiment, positive contrast obtained for about half the master subjects. The rest showed a rate increase in both components (positive induction). Each master subject's key colors and reinforcers were synchronously presented on a response-independent basis to a yoked control. Richer component key-pecking occurred during each experiment's Phases 1 and 3 among half these subjects. However, none responded during the contrast condition (unchanged component of each experiment's Phase 2). From this it is inferred that autoshaping did not contribute to the contrast and induction findings among master birds. Little evidence of local contrast (highest rate at beginning of richer component) was found in any subject. These data show that (a) contrast can occur independently from autoshaping, (b) contrast assays during equal-valued components may produce induction, (c) local contrast in multiple schedules often does not occur, and (d) differential hopper durations can produce autoshaping and contrast. PMID:16812081
Jellis, Christine L; Yingchoncharoen, Teerapat; Gai, Neville; Kusunose, Kenya; Popović, Zoran B; Flamm, Scott; Kwon, Deborah
2018-01-01
Right ventricular (RV) fibrosis is increasingly recognized as the underlying pathological substrate in a variety of clinical conditions. We sought to employ cardiac magnetic resonance (CMR) techniques of strain imaging and longitudinal relaxation time (T 1 ) mapping to better examine the relationship between RV function and structure. Our aim was to initially evaluate the feasibility of these techniques to evaluate the right ventricle. We then sought to explore the relationship between RV function and underlying fibrosis, along with examining the evolution of RV remodeling according to the amount of baseline fibrosis. Echocardiography was performed in 102 subjects with non-ischemic cardiomyopathy. Right ventricular parameters were assessed including: fractional area change (FAC) and longitudinal strain. The same cohort underwent CMR. Post-contrast T 1 mapping was performed as a marker of fibrosis with a Look-Locker technique using inversion recovery imaging. Mid-ventricular post-contrast T 1 values of the RV free wall, RV septum and lateral LV were calculated using prototype analysis software. Biventricular volumetric data including ejection fraction was measured by CMR using a cine short axis stack. CMR strain analysis was also performed to assess 2D RV longitudinal and radial strain. Simultaneous biochemical and anthropometric data were recorded. Subjects were followed over a median time of 29 months (IQR 20-37 months) with echocardiography to evaluate temporal change in RV FAC according to baseline post-contrast T 1 values. Longitudinal data analysis was performed to adjust for patient loss during follow-up. Subjects (62% men, 51 ± 15 years) had mild to moderately impaired global RV systolic function (RVEF = 39 ± 15%; RVEDV = 187 ± 69 ml; RVESV = 119 ± 68 ml) and moderate left ventricular dysfunction at baseline (LVEF 30 ± 17%). Good correlation was observed between mean LV and RV post-contrast T 1 values (r = 0.652, p < 0.001), with similar post-contrast T 1 values maintained in both the RV free wall and septum (r = 0.761, p < 0.001). CMR RVEF demonstrated a proportional correlation with echocardiographic measures of RV longitudinal function and CMR RV strain (longitudinal r = -0.449, p = 0.001; radial r = -0.549, p < 0.001). RVEF was related to RV post-contrast T 1 values, particularly in those with RV dysfunction (free wall T 1 r = 0.259 p = 0.027; septal T 1 r = 0.421 p < 0.001). RV strain was also related to RV post-contrast T 1 values (r = -0.417, p = 0.002). Linear regression analysis demonstrated strain and post-contrast T1 values to be independently associated with RVEF. Subjects with severe RV dysfunction (CMR RVEF <25%) demonstrated lower RV CMR strain (longitudinal p = 0.018; radial p < 0.001), RV T 1 values (free wall p = 0.013; septum <0.001) and RV longitudinal echocardiography parameters despite no difference in afterload. During follow-up, those with RV free wall post-contrast T 1 values ≥ 350 ms demonstrated ongoing improvement in FAC (Δ6%), whilst values <350 ms were associated with deterioration in RV function (ΔFAC = -5%) (p = 0.026). CMR provides a comprehensive method by which to evaluate right ventricular function. Post-contrast T 1 mapping and CMR strain imaging are technically feasible and provide incremental information regarding global RV function and structure. The proportional relationship between RV function and post-contrast T 1 values supports that myocardial fibrosis is a causative factor of RV dysfunction in NICM, irrespective of RV afterload. This same structural milieu also appears integral to the propensity for both positive and negative RV remodeling long-term, suggestive that this is also determined by the degree of underlying RV fibrosis.
Murafuji, Toshihiro; Fujiwara, Yudai; Yoshimatsu, Daisuke; Miyakawa, Isamu; Migita, Kouto; Mikata, Yuji
2011-02-01
A series of heterocyclic organobismuth(III) compounds 2 [ClBi(5-R-C6H(3)-2-SO2C6H(4)-1'-): R=Me, Ph, MeO, Cl, H, t-Bu, CF3, F, Me2N] was synthesized in order to study the relative importance of structure and specific substitutions in relation to their lipophilicity and antifungal activity against the yeast Saccharomyces cerevisiae. A clear structure-activity relationship between the size of the inhibition zone and the value of ClogP was found for 2. These results suggest that the higher the lipophilicity, the lower the antifungal activity. Thus, 2e (R=H) and 2h (R=F), which had ClogP values of 1.18 and 1.45, respectively, were most active. In contrast, 2b (R=Ph) and 2f (R=t-Bu) had ClogP values of 3.06 and 3.00, respectively, and exhibited no antifungal activity. Compound 6b ClBi[5-(OH)C6H(3)-2-SO(2)-5'-(OH)C6H(3)-1'-] had an estimated ClogP value of 0.81 but exhibited only low activity in spite of its low ClogP value, suggesting that such a considerable decrease in lipophilicity lowers inhibition activity. Bismuth carboxylate 7b derived from p-nitrobenzoic acid and 2e exhibited inhibition activity comparable to those of 2e and 2h despite its higher lipophilicity (ClogP=2.68). Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Haji-Momenian, S; Parkinson, W; Khati, N; Brindle, K; Earls, J; Zeman, R K
2018-06-01
To determine the sensitivity, specificity, and predictive values of single-energy non-contrast hepatic steatosis criteria on dual-energy virtual non-contrast (VNC) images. Forty-eight computed tomography (CT) examinations, which included single-energy non-contrast (TNC) and contrast-enhanced dual-energy CT angiography (CTA) of the abdomen, were enrolled. VNC images were reconstructed from the CTA. Region of interest (ROI) attenuations were measured in the right and left hepatic lobes, spleen, and aorta on TNC and VNC images. The right and left hepatic lobes were treated as separate samples. Steatosis was diagnosed based on TNC liver attenuation of ≤40 HU or liver attenuation index (LAI) of ≤-10 HU, which are extremely specific and predictive for moderate to severe steatosis. The sensitivity, specificity, and predictive values of VNC images for steatosis were calculated. VNC-TNC deviations were correlated with aortic enhancement and patient water equivalent diameter (PWED). Thirty-two liver ROIs met steatosis criteria based on TNC attenuation; VNC attenuation had sensitivity, specificity, and a positive predictive value of 66.7%, 100%, and 100%, respectively. Twenty-one liver ROIs met steatosis criteria based on TNC LAI. VNC LAI had sensitivity, specificity, and positive predictive values of 61.9%, 90.7%, and 65%, respectively. Hepatic and splenic VNC-TNC deviations did not correlate with one another (R 2 =0.08), aortic enhancement (R 2 <0.06) or PWED (R 2 <0.09). Non-contrast hepatic attenuation criteria is extremely specific and positively predictive for moderate to severe steatosis on VNC reconstructions from the arterial phase. Hepatic attenuation performs better than LAI criteria. VNC deviations are independent of aortic enhancement and PWED. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Blubaugh, Morgan V.; Uslan, Mark M.
2012-01-01
The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, full-functionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39–1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55–96% and font height ranging 0.28–0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. PMID:22538132
Blubaugh, Morgan V; Uslan, Mark M
2012-03-01
The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, fullfunctionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39-1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55-96% and font height ranging 0.28-0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. © 2012 Diabetes Technology Society.
Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni
2016-10-01
This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.
Kim, Yeon Jin; Gheiratmand, Mina; Mullen, Kathy T
2013-05-28
Cross-orientation masking (XOM) occurs when the detection of a test grating is masked by a superimposed grating at an orthogonal orientation, and is thought to reveal the suppressive effects mediating contrast normalization. Medina and Mullen (2009) reported that XOM was greater for chromatic than achromatic stimuli at equivalent spatial and temporal frequencies. Here we address whether the greater suppression found in binocular color vision originates from a monocular or interocular site, or both. We measure monocular and dichoptic masking functions for red-green color contrast and achromatic contrast at three different spatial frequencies (0.375, 0.75, and 1.5 cpd, 2 Hz). We fit these functions with a modified two-stage masking model (Meese & Baker, 2009) to extract the monocular and interocular weights of suppression. We find that the weight of monocular suppression is significantly higher for color than achromatic contrast, whereas dichoptic suppression is similar for both. These effects are invariant across spatial frequency. We then apply the model to the binocular masking data using the measured values of the monocular and interocular sources of suppression and show that these are sufficient to account for color binocular masking. We conclude that the greater strength of chromatic XOM has a monocular origin that transfers through to the binocular site.
NASA Astrophysics Data System (ADS)
Gemeinhardt, Ines; Puls, Dorothee; Gemeinhardt, Ole; Taupitz, Matthias; Wagner, Susanne; Schnorr, Beatrix; Licha, Kai; Schirner, Michael; Ebert, Bernd; Petzelt, Diethard; Macdonald, Rainer; Schnorr, Jörg
2012-10-01
Using 15 rats with collagen-induced arthritis (30 joints) and 7 control rats (14 joints), we correlated the intensity of near-infrared fluorescence (NIRF) of the nonspecific dye tetrasulfocyanine (TSC) with magnetic resonance imaging (MRI), histopathology, and clinical score. Fluorescence images were obtained in reflection geometry using a NIRF camera system. Normalized fluorescence intensity (INF) was determined after intravenous dye administration on different time points up to 120 min. Contrast-enhanced MRI using gadodiamide was performed after NIRF imaging. Analyses were performed in a blinded fashion. Histopathological and clinical scores were determined for each ankle joint. INF of moderate and high-grade arthritic joints were significantly higher (p<0.005) than the values of control and low-grade arthritic joints between 5 and 30 min after TSC-injection. This result correlated well with post-contrast MRI signal intensities at about 5 min after gadodiamide administration. Furthermore, INF and signal increase on contrast-enhanced MRI showed high correlation with clinical and histopathological scores. Sensitivities and specificities for detection of moderate and high-grade arthritic joints were slightly lower for NIRF imaging (89%/81%) than for MRI (100%/91%). NIRF imaging using TSC, which is characterized by slower plasma clearance compared to indocyanine green (ICG), has the potential to improve monitoring of inflamed joints.
Yuasa, Hajime J; Ball, Helen J
2012-08-01
Indoleamine 2,3-dioxygenase (IDO) is a tryptophan-degrading enzyme and known as a mammalian immunosuppressive molecule. In fungi, the primary role of IDO is to supply nicotinamide adenine dinucleotide (NAD(+)) via the kynurenine pathway. We previously reported that the koji-mold, Aspergillus oryzae has two IDO genes, IDOα and IDOβ. In the present study, we found that A. oryzae also has the third IDO, IDOγ. These three-types of IDOs are widely distributed among the Pezizomycotina fungi, although the black truffle, Tuber melanosporum has only one corresponding gene to IDOα/IDOβ. The yeast, Saccharomyces cerevisiae has a single IDO gene. Generally, Pezizomycotina IDOα showed similar enzymatic properties to the yeast IDO, suggesting that the IDOα is a functional homologue of the S. cerevisiae IDO. In contrast to IDOα, the K(m) value of IDOβ is higher. However, the reaction velocity of IDOβ is very fast, resulting in comparable or higher catalytic efficiency than IDOα. Thus IDOβ may functionally substitute for IDOα in fungal L-Trp metabolism. The enzymatic activity of IDOγ was comparatively very low with the values of enzymatic parameters comparable to vertebrate IDO2 enzymes. IDOα and IDOβ have similar gene structures, suggesting that they were generated by gene duplication which occurred rather early in Pezizomycotina evolution, although the timing of the duplication remains debatable. In contrast, the phylogenetic trees suggest that IDOγs form an evolutionarily distinct group of IDO enzymes, with a closer relationship to group I bacterial IDOs than other fungal IDOs. The ancestor of the IDOγ family is likely to have diverged from other eukaryotic IDOs at a very early stage of eukaryotic evolution. Copyright © 2012. Published by Elsevier B.V.
Simultaneous (68)Ga-DOTA-TOC PET/MRI with gadoxetate disodium in patients with neuroendocrine tumor.
Hope, Thomas A; Pampaloni, Miguel Hernandez; Nakakura, Eric; VanBrocklin, Henry; Slater, James; Jivan, Salma; Aparici, Carina Mari; Yee, Judy; Bergsland, Emily
2015-08-01
To evaluate a simultaneous PET/MRI approach to imaging patients with neuroendocrine tumor using a combination of (68)Ga-DOTA-TOC as a PET contrast agent and gadoxetate disodium as a hepatobiliary MRI contrast agent. Ten patients with neuroendocrine tumor with known or suspected hepatic disease were imaged using a (68)Ga-DOTA-TOC PET/CT immediately followed by a 3.0T time-of-flight PET/MRI, using a combined whole body and liver specific imaging. The presence of lesions and DOTA-TOC avidity were assessed on CT, PET from PET/CT, diffusion weighted imaging, hepatobiliary phase imaging (HBP), and PET from PET/MRI. Maximum standardized uptake values (SUVmax) in hepatic lesions and nodal metastases were compared between PET/CT and PET/MRI, as were detection rates using each imaging approach. A total of 101 hepatic lesions were identified, 47 of which were DOTA-TOC avid and able to be individually measured on both PET/CT and PET/MRI. HBP imaging had a higher sensitivity for detection of hepatic lesions compared to CT or PET (99% vs. 46% and 64%, respectively; p values <0.001). There was a strong correlation between SUVmax of liver lesions obtained with PET/CT compared to PET/MR imaging (Pearson's correlation = 0.91). For nodal disease, CT had a higher sensitivity compared to whole body MRI (p = 0.015), although PET acquired from PET/MRI detected slightly more lesions compared to PET from PET/CT. A simultaneous PET/MRI using both (68)Ga-DOTA-TOC and gadoxetate disodium was successful in whole body staging of patients with neuroendocrine tumor. HBP imaging had an increased detection rate for hepatic metastases.
Adib-Moghaddam, Soheil; Soleyman-Jahi, Saeed; Salmanian, Bahram; Omidvari, Amir-Houshang; Adili-Aghdam, Fatemeh; Noorizadeh, Farsad; Eslani, Medi
2016-11-01
To evaluate the long-term quantitative and qualitative optical outcomes of 1-step transepithelial photorefractive keratectomy (PRK) to correct myopia and astigmatism. Bina Eye Hospital, Tehran, Iran. Prospective interventional case series. Eyes with myopia with or without astigmatism were evaluated. One-step transepithelial PRK was performed with an aberration-free aspheric optimized profile and the Amaris 500 laser. Eighteen-month follow-up results for refraction, visual acuities, vector analysis, higher-order aberrations, contrast sensitivity, postoperative pain, and haze grade were assessed. The study enrolled 146 eyes (74 patients). At the end of follow-up, 93.84% of eyes had an uncorrected distance visual acuity of 20/20 or better and 97.94% of eyes were within ±0.5 diopter of the targeted spherical refraction. On vector analysis, the mean correction index value was close to 1 and the mean index of success and magnitude of error values were close to 0. The achieved correction vector was on an axis counterclockwise to the axis of the intended correction. Photopic and mesopic contrast sensitivities and ocular and corneal spherical, cylindrical, and corneal coma aberrations significantly improved (all P < .001). A slight amount of trefoil aberration was induced (P < .001, ocular aberration; P < .01, corneal aberration). No eye lost more than 1 line of corrected distance visual acuity. No eye had a haze grade of 2+ degrees or higher throughout the follow-up. Eighteen-month results indicate the efficacy and safety of transepithelial PRK to correct myopia and astigmatism. It improved refraction and quality of vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Gettings, M.E.
1983-01-01
Bulk density and magnetic susceptibility of 11 outcrop samples representing the Proterozoic lithologic units at the Baid al Jimalah West tungsten deposit, Kingdom of Saudi Arabia were measured. Induced polarization response, apparent resistivity, and electromagnetic conductivity were determined for four specimens of the sample suite. Measurements show that there is a negative density contrast of about -0.17 g-cm^-3 between metasedimentary rocks of the Murdama group and the Bald al Jimalah graaite and that this contrast decreases with increasing mineralization of the granite. Similarly, the bulk magnetic susceptibility of the granite is about one-third that of the Murdama rocks for this sample suite; however, magnetic susceptibility increases with increasing mineralization in the granite specimens. Electromagnetic conductivities are uniformly low, in part because the specimens are weathered, but probably also because intense silicification accompanies the mineralization. Induced polarization chargeability increases in the granitic specimens with increasing mineralization and reflects higher percentages of sulfide minerals. Chargeability for the mineralized rocks is about four times higher than for the Murdama host rocks, and apparent resistivity values are about one-fifth the values of host rocks. Based on these results, it is recommended that during reconnaissance exploration of the area 15 detailed high-precision gravity profiles at 10 m to 50 m station spacing and eight induced polarization dipole-dipole profiles at 25 m dipole spacing and maximum 'n' of 6 be measured. To help define subsurface structure, a high-precision, ground-magnetic survey (map at 2-gamma contour interval) and a four-channel gamma ray spectrometric survey on a 25x50 m grid covering the area of the profiles are recommended.
Kowtharapu, B S; Winter, K; Marfurt, C; Allgeier, S; Köhler, B; Hovakimyan, M; Stahnke, T; Wree, A; Stachs, O; Guthoff, R F
2017-03-01
PurposeThis study was designed to compare and contrast quantitative data of the human corneal sub-basal nerve plexus (SBP) evaluated by two different methods: in vivo confocal microscopy (IVCM), and immunohistochemical staining of ex vivo donor corneas.MethodsSeven parameters of the SBP in large-scale IVCM mosaicking images from healthy subjects were compared with the identical parameters in ex vivo donor corneas stained by β-III-tubulin immunohistochemistry. Corneal nerve fiber length (CNFL), corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), average weighted corneal nerve fiber tortuosity (CNFTo), corneal nerve connection points (CNCP), average corneal nerve single-fiber length (CNSFL), and average weighted corneal nerve fiber thickness (CNFTh) were calculated using a dedicated, published algorithm and compared.ResultsOur experiments showed significantly higher values for CNFL (50.2 vs 21.4 mm/mm 2 ), CNFD (1358.8 vs 277.3 nerve fibers/mm 2 ), CNBD (847.6 vs 163.5 branches/mm 2 ), CNFTo (0.095 vs 0.081 μm -1 ), and CNCP (49.4 vs 21.6 connections/mm 2 ) in histologically staining specimens compared with IVCM images. In contrast, CNSFL values were higher in IVCM images than in histological specimens (32.1 vs 74.1 μm). No significant difference was observed in CNFTh (2.22 vs 2.20 μm) between the two groups.ConclusionsThe results of this study have shown that IVCM has an inherently lower resolution compared with ex vivo immunohistochemical staining of the corneal SBP and that this limitation leads to a systematic underestimation of several SBP parameters. Despite this shortcoming, IVCM is a vital clinical tool for in vivo characterization, quantitative clinical imaging, and evaluation of the human corneal SBP.
Chan, Sheng-Chieh; Chang, Kai-Ping; Fang, Yu-Hua Dean; Tsang, Ngan-Ming; Ng, Shu-Hang; Hsu, Cheng-Lung; Liao, Chun-Ta; Yen, Tzu-Chen
2017-01-01
Plasma Epstein-Barr virus (EBV) DNA concentrations predict prognosis in patients with nasopharyngeal carcinoma (NPC). Recent evidence also indicates that intratumor heterogeneity on F-18 fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET) scans is predictive of treatment outcomes in different solid malignancies. Here, we sought to investigate the prognostic value of heterogeneity parameters in patients with primary NPC. Retrospective cohort study. We examined 101 patients with primary NPC who underwent pretreatment 18 F-FDG PET/computed tomography. Circulating levels of EBV DNA were measured in all participants. The following PET heterogeneity parameters were collected: histogram-based heterogeneity parameters, second-order texture features (uniformity, contrast, entropy, homogeneity, dissimilarity, inverse difference moment), and higher-order (coarseness, contrast, busyness, complexity, strength) texture features. The median follow-up time was 5.14 years. Total lesion glycolysis (TLG), tumor heterogeneity measured by histogram-based parameter skewness, and the majority of second-order or higher-order texture features were significantly associated with overall survival (OS) and/or recurrence-free survival (RFS). In multivariate analysis, age (P =.005), EBV DNA load (P = .0002), and uniformity (P = .001) independently predicted OS. Only skewness retained the independent prognostic significance for RFS. Tumor stage, standardized uptake value, or TLG did not show an independent association with survival endpoints. The combination of uniformity, EBV DNA load, and age resulted in a more reliable prognostic stratification (P < .001). Tumor heterogeneity is superior to traditional PET parameters for predicting outcomes in primary NPC. The combination of uniformity with EBV DNA load can improve prognostic stratification in this clinical entity. 4 Laryngoscope, 127:E22-E28, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Jin, Lifang; Xu, Changsong; Xie, Xueqian; Li, Fan; Lv, Xiuhong; Du, Lianfang
2017-01-01
Enhancement heterogeneity on contrast-enhanced ultrasonography (CEUS) is used to differentiate between benign and malignant thyroid nodules. In this study, we used an algorithm to quantify enhancement heterogeneity of solid thyroid nodules on CEUS. The heterogeneity value (HV) is calculated as standard deviation/mean intensity × 100 (using Adobe Photoshop). The heterogeneity ratio (HR) is calculated as the ratio of the HV of the nodule to that of the surrounding parenchyma. Three phases-ascending, peak and descending phases-were studied. HV values at ascending (HV a ) and peak (HV p ) phases were significantly higher in malignant nodules than in benign nodules (95.57 ± 43.87 vs. 73.06 ± 44.04, p = 0.009, and 32.53 ± 10.73 vs. 26.44 ± 8.25, p = 0.002, respectively). HR a , HR p and HR d were significantly higher in malignant nodules than in benign nodules (1.93 ± 1.03 vs. 1.00 ± 0.47, p = 0.000, 1.43 ± 0.51 vs. 1.09 ± 0.28, p = 0.000, and 1.33 ± 0.40 vs. 1.08 ± 0.33, p = 0.001, respectively). HR a achieved optimal diagnostic performance on receiver operating characteristic curve analysis. The algorithm used for assessment of image heterogeneity on CEUS examination may be a useful adjunct to conventional ultrasound for differential diagnosis of solid thyroid nodules. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Goldsmith, K. J. A.; Pittard, J. M.
2018-05-01
The similarities, or otherwise, of a shock or wind interacting with a cloud of density contrast χ = 10 were explored in a previous paper. Here, we investigate such interactions with clouds of higher density contrast. We compare the adiabatic hydrodynamic interaction of a Mach 10 shock with a spherical cloud of χ = 103 with that of a cloud embedded in a wind with identical parameters to the post-shock flow. We find that initially there are only minor morphological differences between the shock-cloud and wind-cloud interactions, compared to when χ = 10. However, once the transmitted shock exits the cloud, the development of a turbulent wake and fragmentation of the cloud differs between the two simulations. On increasing the wind Mach number, we note the development of a thin, smooth tail of cloud material, which is then disrupted by the fragmentation of the cloud core and subsequent `mass-loading' of the flow. We find that the normalized cloud mixing time (tmix) is shorter at higher χ. However, a strong Mach number dependence on tmix and the normalized cloud drag time, t_{drag}^' }, is not observed. Mach-number-dependent values of tmix and t_{drag}^' } from comparable shock-cloud interactions converge towards the Mach-number-independent time-scales of the wind-cloud simulations. We find that high χ clouds can be accelerated up to 80-90 per cent of the wind velocity and travel large distances before being significantly mixed. However, complete mixing is not achieved in our simulations and at late times the flow remains perturbed.
Nwe, Kido; Xu, Heng; Regino, Celeste Aida S.; Bernardo, Marcelino; Ileva, Lilia; Riffle, Lisa; Wong, Karen J.; Brechbiel, Martin W.
2009-01-01
In this paper we report a new method to prepare and characterize a contrast agent based on a fourth-generation (G4) polyamidoamine (PAMAM) dendrimer conjugated to the gadolinium complex of the bifunctional diethylenetriamine pentaacetic acid derivative (1B4M-DTPA). The method involves pre-forming the metal-ligand chelate in alcohol prior to conjugation to the dendrimer. The dendrimer-based agent was purified by a Sephadex® G-25 column and characterized by elemental analysis. The analysis and SEHPLC data gave a chelate to dendrimer ratio of 30:1 suggesting conjugation at approximately every other amine terminal on the dendrimer. Molar relaxivity of the agent measured at pH 7.4 displayed a higher value than that of the analogous G4 dendrimer based agent prepared by the post-metal incorporation method (r1 = 26.9 vs. 13.9 mM-1s-1 at 3T and 22°C). This is hypothesized to be due to the higher hydrophobicity of this conjugate, and the lack of available charged carboxylate groups from non-complexed free ligands that might coordinate to the metal and thus also reduce water exchange sites. Additionally, the distribution populations of compounds that result from the post-metal incorporation route are eliminated from the current product simplifying characterization as quality control issues pertaining to the production of such agents for clinical use as MR contrast agents. In vivo imaging in mice showed a reasonably fast clearance (t1/2 = 24 min) suggesting a viable agent for use in clinical application. PMID:19555072
Nwe, Kido; Xu, Heng; Regino, Celeste Aida S; Bernardo, Marcelino; Ileva, Lilia; Riffle, Lisa; Wong, Karen J; Brechbiel, Martin W
2009-07-01
In this paper, we report a new method to prepare and characterize a contrast agent based on a fourth-generation (G4) polyamidoamine (PAMAM) dendrimer conjugated to the gadolinium complex of the bifunctional diethylenetriamine pentaacetic acid derivative (1B4M-DTPA). The method involves preforming the metal-ligand chelate in alcohol prior to conjugation to the dendrimer. The dendrimer-based agent was purified by a Sephadex G-25 column and characterized by elemental analysis. The analysis and SE-HPLC data gave a chelate to dendrimer ratio of 30:1 suggesting conjugation at approximately every other amine terminal on the dendrimer. Molar relaxivity of the agent measured at pH 7.4 displayed a higher value than that of the analogous G4 dendrimer based agent prepared by the postmetal incorporation method (r(1) = 26.9 vs 13.9 mM(-1) s(-1) at 3 T and 22 degrees C). This is hypothesized to be due to the higher hydrophobicity of this conjugate and the lack of available charged carboxylate groups from noncomplexed free ligands that might coordinate to the metal and thus also reduce water exchange sites. Additionally, the distribution populations of compounds that result from the postmetal incorporation route are eliminated from the current product simplifying characterization as quality control issues pertaining to the production of such agents for clinical use as MR contrast agents. In vivo imaging in mice showed a reasonably fast clearance (t(1/2) = 24 min) suggesting a viable agent for use in clinical application.
Robust Short-Lag Spatial Coherence Imaging.
Nair, Arun Asokan; Tran, Trac Duy; Bell, Muyinatu A Lediju
2018-03-01
Short-lag spatial coherence (SLSC) imaging displays the spatial coherence between backscattered ultrasound echoes instead of their signal amplitudes and is more robust to noise and clutter artifacts when compared with traditional delay-and-sum (DAS) B-mode imaging. However, SLSC imaging does not consider the content of images formed with different lags, and thus does not exploit the differences in tissue texture at each short-lag value. Our proposed method improves SLSC imaging by weighting the addition of lag values (i.e., M-weighting) and by applying robust principal component analysis (RPCA) to search for a low-dimensional subspace for projecting coherence images created with different lag values. The RPCA-based projections are considered to be denoised versions of the originals that are then weighted and added across lags to yield a final robust SLSC (R-SLSC) image. Our approach was tested on simulation, phantom, and in vivo liver data. Relative to DAS B-mode images, the mean contrast, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) improvements with R-SLSC images are 21.22 dB, 2.54, and 2.36, respectively, when averaged over simulated, phantom, and in vivo data and over all lags considered, which corresponds to mean improvements of 96.4%, 121.2%, and 120.5%, respectively. When compared with SLSC images, the corresponding mean improvements with R-SLSC images were 7.38 dB, 1.52, and 1.30, respectively (i.e., mean improvements of 14.5%, 50.5%, and 43.2%, respectively). Results show great promise for smoothing out the tissue texture of SLSC images and enhancing anechoic or hypoechoic target visibility at higher lag values, which could be useful in clinical tasks such as breast cyst visualization, liver vessel tracking, and obese patient imaging.
NASA Technical Reports Server (NTRS)
Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.
1993-01-01
We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.
Goebel, Georg; Seppi, Klaus; Donnemiller, Eveline; Warwitz, Boris; Wenning, Gregor K; Virgolini, Irene; Poewe, Werner; Scherfler, Christoph
2011-04-01
The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [(123)I]β-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP(ND)) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP(ND) image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [(123)I]β-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [(123)I]β-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [(123)I]β-CIT SPECT in patients presenting with parkinsonism at their initial visit.
Spectral CT imaging in patients with Budd-Chiari syndrome: investigation of image quality.
Su, Lei; Dong, Junqiang; Sun, Qiang; Liu, Jie; Lv, Peijie; Hu, Lili; Yan, Liangliang; Gao, Jianbo
2014-11-01
To assess the image quality of monochromatic imaging from spectral CT in patients with Budd-Chiari syndrome (BCS), fifty patients with BCS underwent spectral CT to generate conventional 140 kVp polychromatic images (group A) and monochromatic images, with energy levels from 40 to 80, 40 + 70, and 50 + 70 keV fusion images (group B) during the portal venous phase (PVP) and the hepatic venous phase (HVP). Two-sample t tests compared vessel-to-liver contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) for the portal vein (PV), hepatic vein (HV), inferior vena cava. Readers' subjective evaluations of the image quality were recorded. The highest SNR values in group B were distributed at 50 keV; the highest CNR values in group B were distributed at 40 keV. The higher CNR values and SNR values were obtained though PVP of PV (SNR 18.39 ± 6.13 vs. 10.56 ± 3.31, CNR 7.81 ± 3.40 vs. 3.58 ± 1.31) and HVP of HV (3.89 ± 2.08 vs. 1.27 ± 1.55) in the group B; the lower image noise for group B was at 70 keV and 50 + 70 keV (15.54 ± 8.39 vs. 18.40 ± 4.97, P = 0.0004 and 18.97 ± 7.61 vs. 18.40 ± 4.97, P = 0.0691); the results show that the 50 + 70 keV fusion image quality was better than that in group A. Monochromatic energy levels of 40-70, 40 + 70, and 50 + 70 keV fusion image can increase vascular contrast and that will be helpful for the diagnosis of BCS, we select the 50 + 70 keV fusion image to acquire the best BCS images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chawla, Amarpreet S.; Samei, Ehsan; Duke Advanced Imaging Laboratories, Departments of Radiology, Physics, Medical Physics, and Biomedical Engineering, Duke University, Durham, North Carolina 27705
2007-01-15
Ambient lighting in soft-copy reading rooms is currently kept at low values to preserve contrast rendition in the dark regions of a medical image. Low illuminance levels, however, create inadequate viewing conditions and may also cause eye strain. This eye strain may be potentially attributed to notable variations in the luminance adaptation state of the reader's eyes when moving the gaze intermittently between the brighter display and darker surrounding surfaces. This paper presents a methodology to minimize this variation and optimize the lighting conditions of reading rooms by exploiting the properties of liquid crystal displays (LCDs) with low diffuse reflectionmore » coefficients and high luminance ratio. First, a computational model was developed to determine a global luminance adaptation value, L{sub adp}, when viewing a medical image on display. The model is based on the diameter of the pupil size, which depends on the luminance of the observed object. Second, this value was compared with the luminance reflected off surrounding surfaces, L{sub s}, under various conditions of room illuminance, E, different values of diffuse reflection coefficients of surrounding surfaces, R{sub s}, and calibration settings of a typical LCD. The results suggest that for typical luminance settings of current LCDs, it is possible to raise ambient illumination to minimize differences in eye adaptation, potentially reducing visual fatigue while also complying with the TG18 specifications for controlled contrast rendition. Specifically, room illumination in the 75-150 lux range and surface diffuse reflection coefficients in the practical range of 0.13-0.22 sr{sup -1} provide an ideal setup for typical LCDs. Future LCDs with lower diffuse reflectivity and with higher inherent luminance ratios can provide further improvement of ergonomic viewing conditions in reading rooms.« less
Time-shifted synchronization of chaotic oscillator chains without explicit coupling delays.
Blakely, Jonathan N; Stahl, Mark T; Corron, Ned J
2009-12-01
We examine chains of unidirectionally coupled oscillators in which time-shifted synchronization occurs without explicit delays in the coupling. In numerical simulations and in an experimental system of electronic oscillators, we examine the time shift and the degree of distortion (primarily in the form of attenuation) of the waveforms of the oscillators located far from the drive oscillator. Surprisingly, under weak coupling we observe minimal attenuation in spite of a significant total time shift. In contrast, at higher coupling strengths the observed attenuation increases dramatically and approaches the value predicted by an analytically derived estimate. In this regime, we verify directly that generalized synchronization is maintained over the entire chain length despite severe attenuation. These results suggest that weak coupling generally may produce higher quality synchronization in systems for which truly identical synchronization is not possible.
Single electron impact ionization of the methane molecule
NASA Astrophysics Data System (ADS)
Bouamoud, Mammar; Sahlaoui, Mohammed; Benmansour, Nour El Houda; Atomic and Molecular Collisions Team
2014-10-01
Triply differential cross sections (TDCS) results of electron-impact ionization of the inner 2a1 molecular orbital of CH4 are presented in the framework of the Second Born Approximation and compared with the experimental data performed in coplanar asymmetric geometry. The cross sections are averaged on the random orientations of the molecular target for accurate comparison with experiments and are compared also with the theoretical calculations of the Three Coulomb wave (3CW) model. Our results are in good agreement with experiments and 3CW results in the binary peak. In contrast the Second Born Approximation yields a significant higher values compared to the 3CW results for the recoil peak and seems to describe suitably the recoil region where higher order effects can occur with the participation of the recoiling ion in the collision process.
Li, Xiang; Qu, Jin-Rong; Luo, Jun-Peng; Li, Jing; Zhang, Hong-Kai; Shao, Nan-Nan; Kwok, Keith; Zhang, Shou-Ning; Li, Yan-le; Liu, Cui-Cui; Zee, Chi-Shing; Li, Hai-Liang
2014-09-01
To determine the effect of intravenous administration of gadolinium (Gd) contrast medium (Gd-DTPA) on diffusion-weighted imaging (DWI) for the evaluation of normal brain parenchyma vs. brain tumor following a short temporal interval. Forty-four DWI studies using b values of 0 and 1000 s/mm(2) were performed before, immediately after, 1 min after, 3 min after, and 5 min after the administration of Gd-DTPA on 62 separate lesions including 15 meningioma, 17 glioma and 30 metastatic lesions. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) values of the brain tumor lesions and normal brain tissues were measured on pre- and postcontrast images. Statistical analysis using paired t-test between precontrast and postcontrast data were obtained on three brain tumors and normal brain tissue. The SNR and CNR of brain tumors and the SNR of normal brain tissue showed no statistical differences between pre- and postcontrast (P > 0.05). The ADC values on the three cases of brain tumors demonstrated significant initial increase on the immediate time point (P < 0.01) and decrease on following the 1 min time point (P < 0.01) after contrast. Significant decrease of ADC value was still found at 3min and 5min time point in the meningioma group (P < 0.01) with gradual normalization over time. The ADC values of normal brain tissues demonstrated significant initial elevation on the immediately postcontrast DWI sequence (P < 0.01). Contrast medium can cause a slight but statistically significant change on the ADC value within a short temporal interval after the contrast administration. The effect is both time and lesion-type dependent. © 2013 Wiley Periodicals, Inc.
Enceladus' Supersonic Gas Jets' Role in Diurnal Variability of Particle Flux
NASA Astrophysics Data System (ADS)
Hansen, Candice; Esposito, Larry W.; Portyankina, Ganna; Hendrix, Amanda; Colwell, Joshua E.; Aye, Klaus-Michael
2016-10-01
Introduction: The Cassini Ultraviolet Imaging Spectrograph (UVIS) has observed 6 occultations of stars by Enceladus' plume from 2005 to 2011 [1]. Supersonic gas jets were detected, imbedded in the overall expulsion of gas at escape velocity along the tiger stripe fissures that cross Enceladus' south pole [2]. The gas flux can be calculated [1], and is observed to vary just 15% in over 6 years, representing a steady output of ~200 kg/sec. In contrast, the brightness of the particle jets, a proxy for the amount of particles expelled, varies 3x with orbital longitude [3], implicating tidal stresses. This is not necessarily inconsistent with the steady gas flux, which had not been measured at apokrone until now.2016 epsilon Orionis Occultation: In order to investigate whether gas flow increases dramatically at apokrone an occultation observation was inserted into the Cassini tour on March 11, 2016 on orbit 233. Enceladus was at a mean anomaly of 208 at the time of the occultation. Using the same methodology as previously employed the column density has been determined to be 1.5 x 1016 cm-2, giving a gas flux of 250 kg/sec. This value is 20% higher than the average 210 kg/sec, but only 15% higher than the occultations at a mean anomaly of 236; i.e. higher than the others but not by a factor of 2 or 3. The overall expulsion of gas from the south pole of Enceladus thus does not seem to change dramatically with orbital position.Jets: The line of sight to the star pierced the Baghdad I gas jet. The jet data, in contrast to the integrated plume, look significantly different in this dataset. The column density of the jet is higher than observed in previous occultations. The collimation of the jet is more pronounced and from that we derive a mach number of 8-9, compared to a previous value for this jet of 6. We conclude that the higher velocity and increased quantity of gas in the jet close to apokrone indicate that the jets are the primary contributors to the increased particle flux observed at apokrone.References: [1] Hansen, C. J. et al. (2006) Science, 311, 1422-1425. [2] Hansen, C. J. et al. (2008) Nature, 456, 477-479. [3] Hedman, M. M. et al. (2013) Nature, 500, 182-184
Rane, Swati; Talati, Pratik; Donahue, Manus J; Heckers, Stephan
2016-06-01
Inflow-vascular space occupancy (iVASO) measures arterial cerebral blood volume (aCBV) using accurate blood water nulling (inversion time [TI]) when arterial blood reaches the capillary, i.e., at the arterial arrival time. This work assessed the reproducibility of iVASO measurements in the hippocampus and cortex at multiple TIs. The iVASO approach was implemented at multiple TIs in 10 healthy volunteers at 3 Tesla. aCBV values were measured at each TI in the left and right hippocampus, and the cortex. Reproducibility of aCBV measurements within scans (same day) and across sessions (different days) was assessed using the intraclass correlation coefficient (ICC). Overall hippocampal aCBV was significantly higher than cortical aCBV, likely due to higher gray matter volume. Hippocampal ICC values were high at short TIs (≤914 ms; intrascan values = 0.80-0.96, interscan values = 0.61-0.91). Cortically, high ICC values were observed at intermediate TIs of 914 (intra: 0.93, inter: 0.87) and 1034 ms (intra: 0.96, inter: 0.86). The ICC values were comparable to established contrast-based CBV measures. iVASO measurements are reproducible within and across sessions. TIs for iVASO measurements should be chosen carefully, taking into account heterogeneous arterial arrival times in different brain regions. Magn Reson Med 75:2379-2387, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
SU-E-T-550: Modulation Index for VMAT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J; Park, S; Kim, J
2015-06-15
Purpose: To present modulation indices (MIs) for volumetric modulated arc therapy (VMAT). Methods: A total of 40 VMAT plans were retrospectively selected. To investigate the delivery accuracy of each VMAT plan, gamma passing rates, differences in modulating parameters between plans and log files, and differences between the original plans and the plans reconstructed with the log files were acquired. A modulation index (MIt) was designed by multiplications of the weighted quantifications of MLC speeds, MLC accelerations, gantry accelerations and dose-rate variations. Textural features including angular second moment, inverse difference moment, contrast, variance, correlation and entropy were calculated from the fluencesmore » of each VMAT plan. To test the performance of suggested MIs, Spearman’s rank correlation coefficients (r) with the plan delivery accuracy were calculated. Conventional modulation indices for VMAT including the modulation complexity score for VMAT (MCSv), leaf travel modulation complexity score (LTMCS) and MI by Li & Xing were calculated, and their correlations were also analyzed in the same way. Results: The r values of contrast (particular displacement distance, d = 1), variance (d = 1), MIt, MCSv, LTMCS and MI by Li&Xing to the local gamma passing rates with 2%/2 mm were 0.547 (p < 0.001), 0.519 (p < 0.001), −0.658 (p < 0.001), 0.186 (p = 0.251), 0.312 (p = 0.05) and −0.455 (p = 0.003), respectively. The r values of those to the MLC errors were −0.863, −0.828, 0.917, −0.635, − 0.857 and 0.795, respectively (p < 0.001). For dose-volumetric parameters, MIt showed higher statistically significant correlations than did the conventional modulation indices. Conclusion: The MIt, contrast (d = 1) and variance (d = 1) showed good performance to predict the VMAT delivery accuracy showing higher correlations to the results of various types of verification methods for VMAT. This work was in part supported by the National Research Foundation of Korea (NRF) grant (no. 490-20140029 and no. 490-20130047) funded by the Korea government.« less
Micromechanics of Friction in a Detailed Study of Mg-rich Phyllosilicates
NASA Astrophysics Data System (ADS)
Sanchez Roa, C.; Faulkner, D.; Boulton, C. J.; Jimenez Millan, J.; Nieto, F.
2016-12-01
Phyllosilicate minerals commonly occur within faults, which may accommodate slip either aseismically via creep mechanisms or seismically in earthquakes. The Mg-rich phyllosilicates talc, saponite, sepiolite, and palygorskite have different crystallography and habits. Sepiolite and palygorskite are fibrous due to their discontinuous tetrahedral layers, while saponite and talc are platy due to the continuity of their TOT and water layers. Friction experiments were conducted in a triaxial apparatus under 95 MPa effective normal stress with water and argon as pore fluids. Results show a marked contrast between friction coefficients of fibrous phyllosilicates, 0.57 to 0.63 for argon experiments and 0.4 to 0.5 for water-saturated experiments, and platy Mg-rich phyllosilicates, as low as 0.22 for argon experiments and 0.04 for water-saturated experiments. During velocity steps (where sliding velocity is increased or decreased by one order of magnitude), the two mineral groups exhibit distinctly dissimilar behaviours. After the direct effect of the change in sliding rate, fibrous phyllosilicates show a rapid exponential decay towards a new friction coefficient (a positive b value). Meanwhile, the friction coefficient of the platy phyllosilicates has a more linear evolution (a zero, or negative b value). This effect could be related to a difference in the sliding strength of the contact asperities which would be much higher for crystal surfaces of fibrous minerals with an indented surface due to the silicon tetrahedra inversions. The fibre-shaped crystals may consequently require higher amounts of volumetric work against the normal stress (dilatancy). SEM and TEM observations of the deformed samples showed a well-developed network of R1 Riedel shears in the fibrous materials; planar phyllosilicates show a more homogeneous matrix and incipient development of P foliation. Planar phyllosilicate grains align on their basal planes facilitating intergranular sliding, in contrast, the fibrous phyllosilicates appear to form an interlocking grid-like network that may promote dilatancy during velocity steps. The contrasting strength of Mg-rich phyllosilicates and analysis of their microstructures imply that phyllosilicate habit strongly influences the micromechanics of frictional sliding.
WE-FG-207B-11: Objective Image Characterization of Spectral CT with a Dual-Layer Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozguner, O; Halliburton, S; Dhanantwari, A
2016-06-15
Purpose: To obtain objective reference data for the spectral performance on a dual-layer detector CT platform (IQon, Philips) and compare virtual monoenergetic to conventional CT images. Methods: Scanning was performed using the hospital’s clinical adult body protocol: helical acquisition at 120kVp, with CTDIvol=15mGy. Multiple modules (591, 515, 528) of a CATPHAN 600 phantom and a 20 cm diameter cylindrical water phantom were scanned. No modifications to the standard protocol were necessary to enable spectral imaging. Both conventional and virtual monoenergetic images were generated from acquired data. Noise characteristics were assessed through Noise Power Spectra (NPS) and pixel standard deviation frommore » water phantom images. Spatial resolution was evaluated using Modulation Transfer Functions (MTF) of a tungsten wire as well as resolution bars. Low-contrast detectability was studied using contrast-to-noise ratio (CNR) of a low contrast object. Results: MTF curves of monoenergetic and conventional images were almost identical. MTF 50%, 10%, and 5% levels for monoenergetic images agreed with conventional images within 0.05lp/cm. These observations were verified by the resolution bars, which were clearly resolved at 7lp/cm but started blurring at 8lp/cm for this protocol in both conventional and 70 keV images. NPS curves indicated that, compared to conventional images, the noise power distribution of 70 keV monoenergetic images is similar (i.e. noise texture is similar) but exhibit a low frequency peak at keVs higher and lower than 70 keV. Standard deviation measurements show monoenergetic images have lower noise except at 40 keV where it is slightly higher. CNR of monoenergetic images is mostly flat across keV values and is superior to that of conventional images. Conclusion: Values for standard image quality metrics are the same or better for monoenergetic images compared to conventional images. Results indicate virtual monoenergetic images can be used without any loss in image quality or noise penalties relative to conventional images. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.« less
Matsuo, Masayuki; Kanematsu, Masayuki; Itoh, Kyo; Murakami, Takamichi; Maetani, Yoji; Kondo, Hiroshi; Goshima, Satoshi; Kako, Nobuo; Hoshi, Hiroaki; Konishi, Junji; Moriyama, Noriyuki; Nakamura, Hironobu
2004-01-01
The purpose of our study was to compare the detectability of malignant hepatic tumors on ferumoxides-enhanced MRI using five gradient-recalled echo sequences at different TEs. Ferumoxides-enhanced MRIs obtained in 31 patients with 50 malignant hepatic tumors (33 hepatocellular carcinomas, 17 metastases) were reviewed retrospectively by three independent offsite radiologists. T1-weighted gradient-recalled echo images with TEs of 1.4 and 4.2 msec; T2*-weighted gradient-recalled echo images with TEs of 6, 8, and 10 msec; and T2-weighted fast spin-echo images of livers were randomly reviewed on a segment-by-segment basis. Observer performance was tested using the McNemar test and receiver operating characteristic analysis for the clustered data. Lesion-to-liver contrast-to-noise ratio was also assessed. Mean lesion-to-liver contrast-to-noise ratios were negative and lower with gradient-recalled echo at 1.4 msec than with the other sequences. Sensitivity was higher (p < 0.05) with gradient-recalled echo at 6, 8, and 10 msec and fast spin-echo sequences (75-83%) than with gradient-recalled echo sequences at 1.4 and 4.2 msec (46-48%), and was higher (p < 0.05) with gradient-recalled echo sequence at 8 msec (83%) than with gradient-recalled echo at 6 msec and fast spin-echo sequences (75-78%). Specificity was comparably high with all sequences (95-98%). The area under the receiver operating characteristic curve (A(z)) was greater (p < 0.05) with gradient-recalled echo at 6, 8, and 10 msec and fast spin-echo sequences (A(z) = 0.91-0.93) than with gradient-recalled echo sequences at 1.4 and 4.2 msec (A(z) = 0.82-0.85). In the detection of malignant hepatic tumors, gradient-recalled echo sequences at 8 msec showed the highest sensitivity and had an A(z) value and lesion-to-liver contrast-to-noise ratio comparable with values from gradient-recalled echo sequences at 6 and 10 msec and fast spin-echo sequences.
Permutation methods for the structured exploratory data analysis (SEDA) of familial trait values.
Karlin, S; Williams, P T
1984-07-01
A collection of functions that contrast familial trait values between and across generations is proposed for studying transmission effects and other collateral influences in nuclear families. Two classes of structured exploratory data analysis (SEDA) statistics are derived from ratios of these functions. SEDA-functionals are the empirical cumulative distributions of the ratio of the two contrasts computed within each family. SEDA-indices are formed by first averaging the numerator and denominator contrasts separately over the population and then forming their ratio. The significance of SEDA results are determined by a spectrum of permutation techniques that selectively shuffle the trait values across families. The process systematically alters certain family structure relationships while keeping other familial relationships intact. The methodology is applied to five data examples of plasma total cholesterol concentrations, reported height values, dermatoglyphic pattern intensity index scores, measurements of dopamine-beta-hydroxylase activity, and psychometric cognitive test results.
Chatzigianni, Martina; Alkhaled, Bara'a; Livieratos, Ioannis; Stamatakis, Aristidis; Ntatsi, Georgia; Savvas, Dimitrios
2018-03-01
In the present study, two contrasting stamnagathi (Cichorium spinosum L.) ecotypes originating either from a mountainous or from a seaside habitat were grown hydroponically and supplied with a nutrient solution differing in the total-N level (4 or 16 mmol L -1 ) and the N source (NH 4 + -N/total-N: 0.05, 0.25 or 0.50). The aim was to search for genotypic differences in nitrogen nutrition. At commercial maturity, the dry weight of mountainous plants was higher than that of seaside plants. The shoot mineral concentrations were higher in seaside plants than in mountainous plants in both harvests. The leaf nitrate concentration was influenced by the levels of both total-N and NH 4 + -N/total-N at both harvests, whereas plants with a seaside origin exhibited higher nitrate concentrations than those originating from a mountainous site in all total-N and NH 4 + -N/total-N treatments. The two stamnagathi ecotypes differed considerably in their responses to nitrogen nutrition and tissue nitrate content. The mountainous ecotype was superior in terms of growth, tissue nitrate concentration and antioxidant capacity, whereas the seaside ecotype accumulated more nutrient microcations in leaves. A low total-N concentration (up to 4 mmol L -1 ) combined with a high NH 4 + -N/total-N ratio (up to 0.05) could minimize tissue NO 3 - concentrations without compromising yield. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Harward, Stephen; Harrison Farber, S; Malinzak, Michael; Becher, Oren; Thompson, Eric M
2018-03-01
Diffuse intrinsic pontine glioma (DIPG) remains the main cause of death in children with brain tumors. Given the inefficacy of numerous peripherally delivered agents to treat DIPG, convection enhanced delivery (CED) of therapeutic agents is a promising treatment modality. The purpose of this study was to determine which MR imaging type provides the best discrimination of intratumoral heterogeneity to guide future stereotactic implantation of CED catheters into the most cellular tumor regions. Patients ages 18 years or younger with a diagnosis of DIPG from 2000 to 2015 were included. Radiographic heterogeneity index (HI) of the tumor was calculated by measuring the standard deviation of signal intensity of the tumor (SD Tumor ) normalized to the genu of the corpus callosum (SD Corpus Callosum ). Four MR image types (T2-weighted, contrast-enhanced T1-weighted, FLAIR, and ADC) were analyzed at several time points both before and after radiotherapy and chemotherapy. HI values across these MR image types were compared and correlated with patient survival. MR images from 18 patients with DIPG were evaluated. The mean survival ± standard deviation was 13.8 ± 13.7 months. T2-weighted images had the highest HI (mean ± SD, 5.1 ± 2.5) followed by contrast-enhanced T1-weighted images (3.7 ± 1.5), FLAIR images (3.0 ± 1.1), and ADC maps (1.6 ± 0.4). ANOVA demonstrated that HI values were significantly higher for T2-weighted images than FLAIR (p < 0.01) and ADC (p < 0.0001). Following radiotherapy, T2-weighted and contrast-enhanced T1-weighted image HI values increased, while FLAIR and ADC HI values decreased. Univariate and multivariate analyses did not reveal a relationship between HI values and patient survival (p > 0.05). For children with DIPG, T2-weighted MRI demonstrates the greatest signal intensity variance suggesting tumor heterogeneity. Within this heterogeneity, T2-weighted signal hypointensity is known to correlate with increased cellularity and thus may represent a putative target for CED catheter placement in future clinical trials.
Nam, J G; Kang, K M; Choi, S H; Lim, W H; Yoo, R-E; Kim, J-H; Yun, T J; Sohn, C-H
2017-12-01
Glioblastoma is the most common primary brain malignancy and differentiation of true progression from pseudoprogression is clinically important. Our purpose was to compare the diagnostic performance of dynamic contrast-enhanced pharmacokinetic parameters using the fixed T1 and measured T1 on differentiating true from pseudoprogression of glioblastoma after chemoradiation with temozolomide. This retrospective study included 37 patients with histopathologically confirmed glioblastoma with new enhancing lesions after temozolomide chemoradiation defined as true progression ( n = 15) or pseudoprogression ( n = 22). Dynamic contrast-enhanced pharmacokinetic parameters, including the volume transfer constant, the rate transfer constant, the blood plasma volume per unit volume, and the extravascular extracellular space per unit volume, were calculated by using both the fixed T1 of 1000 ms and measured T1 by using the multiple flip-angle method. Intra- and interobserver reproducibility was assessed by using the intraclass correlation coefficient. Dynamic contrast-enhanced pharmacokinetic parameters were compared between the 2 groups by using univariate and multivariate analysis. The diagnostic performance was evaluated by receiver operating characteristic analysis and leave-one-out cross validation. The intraclass correlation coefficients of all the parameters from both T1 values were fair to excellent (0.689-0.999). The volume transfer constant and rate transfer constant from the fixed T1 were significantly higher in patients with true progression ( P = .048 and .010, respectively). Multivariate analysis revealed that the rate transfer constant from the fixed T1 was the only independent variable (OR, 1.77 × 10 5 ) and showed substantial diagnostic power on receiver operating characteristic analysis (area under the curve, 0.752; P = .002). The sensitivity and specificity on leave-one-out cross validation were 73.3% (11/15) and 59.1% (13/20), respectively. The dynamic contrast-enhanced parameter of rate transfer constant from the fixed T1 acted as a preferable marker to differentiate true progression from pseudoprogression. © 2017 by American Journal of Neuroradiology.
Assessment of the effects of CT dose in averaged x-ray CT images of a dose-sensitive polymer gel
NASA Astrophysics Data System (ADS)
Kairn, T.; Kakakhel, M. B.; Johnston, H.; Jirasek, A.; Trapp, J. V.
2015-01-01
The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.
Zhang, Wei; Hu, Hong; Zhang, Shi-Bao
2016-01-01
Due to the fluctuating water availability in the arboreal habitat, epiphytic plants are considered vulnerable to climate change and anthropogenic disturbances. Although co-occurring taxa have been observed divergent adaptive performances in response to drought, the underlying physiological and morphological mechanisms by which epiphyte species cope with water stress remain poorly understood. In the present study, two co-occurring epiphytic orchids with different phenologies were selected to investigate their drought-resistance performances. We compared their functional traits, and monitored their physiological performances in a 25-days of drought treatment. In contrast to the deciduous species Pleione albiflora, the evergreen species Coelogyne corymbosa had different root anatomical structures and higher values for saturated water content of pseudobulbs. Moreover, plants of C. corymbosa had thicker leaves and epidermis, denser veins and stomata, and higher values for leaf mass per unit area and the time required to dry saturated leaves to 70% relative water content. However, samples from that species had lower values for net photosynthetic rate (A n), stomatal length and chlorophyll content per unit dry mass. Nevertheless, due to greater capacity for water storage and conservation, C. corymbosa maintained higher A n, stomatal conductance (g s), and instantaneous water-use efficiency during severe drought period, and their values for leaf water potential were higher after the water stress treatment. By Day 10 after irrigation was restarted, only C. corymbosa plants recovered their values for A n and g s to levels close to those calculated prior to the imposition of water stress. Our results suggest that the different performance responding to drought and re-watering in two co-occurring epiphytic orchids is related to water-related traits and these two species have divergent adaptive mechanisms. Overall, C. corymbosa demonstrates drought avoidance by enhancing water uptake and storage, and by reducing water losses while P. albiflora employs a drought escape strategy by fixing more carbon during growing season and shedding leaves and roots at dry season, leaving a dormant pseudobulb to minimize transpiration. These findings may improve our understanding of the potential effects that climate change can have on the population dynamics of different epiphytic taxa.
Petrosino, V; Motta, G; Tenore, G; Coletta, M; Guariglia, A; Testa, D
2018-04-01
Previous literature has highlighted the mechanisms of molecular toxicity induced by substances such as arsenic, cadmium, chromium, nickel, lead, barium and PCBs. The research was carried out on 20 volunteers, all the patients gave their consent to the research: the aim of the study was to evaluate the presence of metals and PCBs in these different matrices (blood and hair), correlating the biochemical data to pathological conditions present, and also to the area in which patients resided. Various quantitative determinations were carried out on samples of blood and hair for 14 heavy metals and on blood samples for 12 PCBs. For the 11 patients the results indicated that blood levels for half of the 14 displayed heavy metals measured considerably higher compared to the reference values, whilst the levels measured in hair evidenced some positive values significantly higher than the maximum reference. Of the 12 PCBs assayed in blood some showed higher positive values compared to the maximum tabular reference (although there is no clear reference quantified in the WHO-2005 report). In the 9 healthy patients heavy metals in the blood were within the expected target range, with those showing positive results (≤ 3 out of 14 heavy metals for each patient) having values only slightly higher than the reference maximum. The levels of 14 heavy metals measured in hair were below thresholds, and levels for the 12 PCBs measured in blood showed negativity or positivity with values close to the minimum benchmarks. The analyses carried out on biological matrices have uncovered important and significant differences between healthy and unhealthy subjects, both qualitative and quantitative differences with respect to heavy metals and PCBs. All patients with head and neck cancer enlisted for the study had heavy metal and PCB blood levels at least twice the maximum reference level. The levels of heavy metals in hair were at least double the maximum reference. In contrast, all healthy volunteers enrolled showed no significant levels for either metals or PCBs.
Delakis, Ioannis; Wise, Robert; Morris, Lauren; Kulama, Eugenia
2015-11-01
The purpose of this work was to evaluate the contrast-detail performance of full field digital mammography (FFDM) systems using ideal (Hotelling) observer Signal-to-Noise Ratio (SNR) methodology and ascertain whether it can be considered an alternative to the conventional, automated analysis of CDMAM phantom images. Five FFDM units currently used in the national breast screening programme were evaluated, which differed with respect to age, detector, Automatic Exposure Control (AEC) and target/filter combination. Contrast-detail performance was analysed using CDMAM and ideal observer SNR methodology. The ideal observer SNR was calculated for input signal originating from gold discs of varying thicknesses and diameters, and then used to estimate the threshold gold thickness for each diameter as per CDMAM analysis. The variability of both methods and the dependence of CDMAM analysis on phantom manufacturing discrepancies also investigated. Results from both CDMAM and ideal observer methodologies were informative differentiators of FFDM systems' contrast-detail performance, displaying comparable patterns with respect to the FFDM systems' type and age. CDMAM results suggested higher threshold gold thickness values compared with the ideal observer methodology, especially for small-diameter details, which can be attributed to the behaviour of the CDMAM phantom used in this study. In addition, ideal observer methodology results showed lower variability than CDMAM results. The Ideal observer SNR methodology can provide a useful metric of the FFDM systems' contrast detail characteristics and could be considered a surrogate for conventional, automated analysis of CDMAM images. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Barreto, Jackson; Barboni, Mirella T S; Feitosa-Santana, Claudia; Sato, João R; Bechara, Samir J; Ventura, Dora F; Alves, Milton Ruiz
2010-08-01
To compare intraocular straylight measurements and contrast sensitivity after wavefront-guided LASIK (WFG LASIK) in one eye and wavefront-guided photorefractive keratectomy (WFG PRK) in the fellow eye for myopia and myopic astigmatism correction. A prospective, randomized study of 22 eyes of 11 patients who underwent simultaneous WFG LASIK and WFG PRK (contralateral eye). Both groups were treated with the NIDEK Advanced Vision Excimer Laser System, and a microkeratome was used for flap creation in the WFG LASIK group. High and low contrast visual acuity, wavefront analysis, contrast sensitivity, and retinal straylight measurements were performed preoperatively and at 3, 6, and 12 months postoperatively. A third-generation straylight meter, C-Quant (Oculus Optikgeräte GmbH), was used for measuring intraocular straylight. Twelve months postoperatively, mean uncorrected distance visual acuity was -0.06 +/- 0.07 logMAR in the WFG LASIK group and -0.10 +/- 0.10 logMAR in the WFG PRK group. Mean preoperative intraocular straylight was 0.94 +/- 0.12 logs for the WFG LASIK group and 0.96 +/- 0.11 logs for the WFG PRK group. After 12 months, the mean straylight value was 1.01 +/- 0.1 log s for the WFG LASIK group and 0.97 +/- 0.12 log s for the WFG PRK group. No difference was found between techniques after 12 months (P = .306). No significant difference in photopic and mesopic contrast sensitivity between groups was noted. Intraocular straylight showed no statistically significant increase 1 year after WFG LASIK and WFG PRK. Higher order aberrations increased significantly after surgery for both groups. Nevertheless, WFG LASIK and WFG PRK yielded excellent visual acuity and contrast sensitivity performance without significant differences between techniques.
Decano, Julius L.; Moran, Anne Marie; Ruiz-Opazo, Nelson; Herrera, Victoria L. M.
2011-01-01
Purpose Given that carotid vasa vasorum neovascularization is associated with increased risk for stroke and cardiac events, the present in vivo study was designed to investigate molecular imaging of carotid artery vasa vasorum neovascularization via target-specific contrast-enhanced ultrasound (CEU) micro-imaging. Procedures Molecular imaging was performed in male transgenic rats with carotid artery disease and non-transgenic controls using dual endothelin1/VEGFsp receptor (DEspR)-targeted microbubbles (MBD) and the Vevo770 micro-imaging system and CEU imaging software. Results DEspR-targeted CEU-positive imaging exhibited significantly higher contrast intensity signal (CIS)-levels and pre-/post-destruction CIS-differences in seven of 13 transgenic rats, in contrast to significantly lower CIS-levels and differences in control isotype-targeted microbubble (MBC)-CEU imaging (n =8) and in MBD CEU-imaging of five non-transgenic control rats (P<0.0001). Ex vivo immunofluorescence analysis demonstrated binding of MBD to DEspR-positive endothelial cells; and association of DEspR-targeted increased contrast intensity signals with DEspR expression in vasa vasorum neovessel and intimal lesions. In vitro analysis demonstrated dose-dependent binding of MBD to DEspR-positive human endothelial cells with increasing %cells bound and number of MBD per cell, in contrast to MBC or non-labeled microbubbles (P<0.0001). Conclusion In vivo DEspR-targeted molecular imaging detected increased DEspR-expression in carotid artery lesions and in expanded vasa vasorum neovessels in transgenic rats with carotid artery disease. Future studies are needed to determine predictive value for stroke or heart disease in this transgenic atherosclerosis rat model and translational applications. PMID:20972637
Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li
2016-04-01
Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P <0.01). In patients with obesity, isotonic contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Toh, Cheng Hong; Wei, Kuo-Chen; Chang, Chen-Nen; Ng, Shu-Hang; Wong, Ho-Fai; Lin, Ching-Po
2014-01-01
To compare the diagnostic performance of dynamic susceptibility contrast-enhanced perfusion MRI before and after mathematic contrast leakage correction in differentiating pyogenic brain abscesses from glioblastomas and/or metastatic brain tumors. Cerebral blood volume (CBV), leakage-corrected CBV and leakage coefficient K2 were measured in enhancing rims, perifocal edema and contralateral normal appearing white matter (NAWM) of 17 abscesses, 19 glioblastomas and 20 metastases, respectively. The CBV and corrected CBV were normalized by dividing the values in the enhancing rims or edema to those of contralateral NAWM. For each study group, a paired t test was used to compare the K2 of the enhancing rims or edema with those of NAWM, as well as between CBV and corrected CBV of the enhancing rims or edema. ANOVA was used to compare CBV, corrected CBV and K2 among three lesion types. The diagnostic performance of CBV and corrected CBV was assessed with receiver operating characteristic (ROC) curve analysis. The CBV and correction CBV of enhancing rim were 1.45±1.17 and 1.97±1.01 for abscesses, 3.85±2.19 and 4.39±2.33 for glioblastomas, and 2.39±0.90 and 2.97±0.78 for metastases, respectively. The CBV and corrected CBV in the enhancing rim of abscesses were significantly lower than those of glioblastomas and metastases (P = 0.001 and P = 0.007, respectively). In differentiating abscesses from glioblastomas and metastases, the AUC values of corrected CBV (0.822) were slightly higher than those of CBV (0.792). Mathematic leakage correction slightly increases the diagnostic performance of CBV in differentiating pyogenic abscesses from necrotic glioblastomas and cystic metastases. Clinically, DSC perfusion MRI may not need mathematic leakage correction in differentiating abscesses from glioblastomas and/or metastases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leng, S; Vrieze, T; Kuhlmann, J
2014-06-15
Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight availablemore » printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.« less
Formation and transport of the sulfonic acid metabolites of alachlor and metolachlor in soil
Aga, D.S.; Thurman, E.M.
2001-01-01
Alachlor and metolachlor are dechlorinated and transformed into their corresponding ethane sulfonic acid (ESA) metabolites in soil. In a field-disappearance study, it was shown that alachlor ESA was formed at a faster rate and at concentrations 2-4 times higher than metolachlor ESA, conforming with the observed longer disappearance half-life of metolachlor (15.5 d) in the field as compared to alachlor (8 d). Runoff data also showed higher concentrations of alachlor ESA as compared to metolachlor ESA, even though they were applied at the same levels. Data from soil cores showed transport of the ESA compounds in soil to as far down as 75-90 cm below the surface, at concentrations ranging from less than 0.5 ??g/L to about 50 ??g/L. In contrast, no parent herbicide was detected at these depths. This observation correlates with the higher log KOC values for alachlor (3.33) and metolachlor (3.01) relative to their corresponding ESA metabolites, alachlor ESA (2.26), and metolachlor ESA (2.29).
Factorial analysis of diesel engine performance using different types of biofuels.
Tashtoush, Ghassan M; Al-Widyan, Mohamad I; Albatayneh, Aiman M
2007-09-01
In this study, several bio-source-fuels like fresh and waste vegetable oil and waste animal fat were tested at different injector pressures (120, 140, 190, 210 bar) in a direct-injection, naturally aspirated, single-cylinder diesel engine with a design injection pressure of 190 bar. Using 2k factorial analysis, the effect of injection pressure (Pi) and fuel type on three engine parameters, namely, combustion efficiency (etac), mass fuel consumption (mf), and engine speed (N) was examined. It was found that Pi and fuel type significantly affected both etac and mf while they had a slight effect on engine speed. Moreover, with diesel and biodiesels, the etac increased to a maximum at 190 bar but declined at the higher Pi value. In contrast, higher Pi had a favorable effect on etac over the whole Pi range with all the other more viscous fuels tested. In addition, the mass fuel consumption consistently decreased with an increase in Pi for all the fuels including the baseline diesel fuel, with which the engine consistently attained higher etac and higher rpm compared to all the other fuels tested.
The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abedin, Ahmad Firdaus Zainal; Ibrahim, Noorddin; Zabidi, Noriza Ahmad
The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measuredmore » 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.« less
Experimentally determined spectral optimization for dedicated breast computed tomography.
Prionas, Nicolas D; Huang, Shih-Ying; Boone, John M
2011-02-01
The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material/thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT technique factors. A cadaveric breast specimen was acquired under appropriate approval and scanned using a prototype bCT scanner. Inserted into the specimen were cylindrical inserts of polyethylene, water, iodine contrast medium (iodixanol, 2.5 mg/ml), and calcium hydroxyapatite (100 mg/ml). Six x-ray tube potentials (50, 60, 70, 80, 90, and 100 kVp) and three different filters (0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn) were tested. For each set of technique factors, the intensity (linear attenuation coefficient) and noise were measured within six regions of interest (ROIs): Glandular tissue, adipose tissue, polyethylene, water, iodine contrast medium, and calcium hydroxyapatite. Dose-normalized contrast to noise ratio (CNRD) was measured for pairwise comparisons among the six ROIs. Regression models were used to estimate the effect of tube potential and added filtration on intensity, noise, and CNRD. Iodine contrast enhancement was maximized using 60 kVp and 0.2 mm Cu. Microcalcification contrast and soft-tissue contrast were maximized at 60 kVp. The 0.2 mm Cu filter achieved significantly higher CNRD for iodine contrast enhancement than the other two filters (p = 0.01), but microcalcification contrast and soft-tissue contrast were similar using the copper and aluminum filters. The average percent difference in linear attenuation coefficient, across all tube potentials, for polyethylene versus adipose tissue was 1.8%, 1.7%, and 1.3% for 0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn, respectively. For water versus glandular tissue, the average percent difference was 2.7%, 3.9%, and 4.2% for the three filter types. Contrast-enhanced bCT, using injected iodine contrast medium, may be optimized for maximum contrast of enhancing lesions at 60 kVp with 0.2 mm Cu filtration. Soft-tissue contrast and microcalcification contrast may also benefit from lower tube potentials (60 kVp). The linear attenuation coefficients of water and polyethylene slightly overestimate the values of their corresponding tissues, but the reported differences may serve as guidance for dosimetry and quality assurance using tissue equivalent phantoms.
Study of risk factors for gastric cancer by populational databases analysis
Ferrari, Fangio; Reis, Marco Antonio Moura
2013-01-01
AIM: To study the association between the incidence of gastric cancer and populational exposure to risk/protective factors through an analysis of international databases. METHODS: Open-access global databases concerning the incidence of gastric cancer and its risk/protective factors were identified through an extensive search on the Web. As its distribution was neither normal nor symmetric, the cancer incidence of each country was categorized according to ranges of percentile distribution. The association of each risk/protective factor with exposure was measured between the extreme ranges of the incidence of gastric cancer (under the 25th percentile and above the 75th percentile) by the use of the Mann-Whitney test, considering a significance level of 0.05. RESULTS: A variable amount of data omission was observed among all of the factors under study. A weak or nonexistent correlation between the incidence of gastric cancer and the study variables was shown by a visual analysis of scatterplot dispersion. In contrast, an analysis of categorized incidence revealed that the countries with the highest human development index (HDI) values had the highest rates of obesity in males and the highest consumption of alcohol, tobacco, fruits, vegetables and meat, which were associated with higher incidences of gastric cancer. There was no significant difference for the risk factors of obesity in females and fish consumption. CONCLUSION: Higher HDI values, coupled with a higher prevalence of male obesity and a higher per capita consumption of alcohol, tobacco, fruits, vegetables and meat, are associated with a higher incidence of gastric cancer based on an analysis of populational global data. PMID:24409066
Place of residence does not significantly influence radiological morphology of cervical cancer.
Burdan, Franciszek; Mocarska, Agnieszka; Klepacz, Robert; Walocha, Jerzy; Kubiatowski, Tomasz; Surdyka, Dariusz; Kieszko, Dariusz; Patyra, Krzysztof; Żelzowska-Cieślińska, Iwonna; Starosławska, Elżbieta
2017-09-21
Cervical squamous cell carcinoma is one of the most common malignancies of women. Its incidence and morphology was analyzed based on the magnetic resonance (MR) data among rural and urban residents. The study involved 61 Caucasian women (58.26±9.63 years) preliminary diagnosed with a cervical cancer without any previous treatment. Standard MR examination, including diffusion weighted imagining, apparent diffusion coefficient (ADC) value measurement and dynamic contrast enhancement, was performed. The rural residents (n=22) were insignificantly older. Their first and last menstruation were observed later and number of pregnancy was higher than in urban women (n=39). However, the incidence of miscarriage was insignificantly rarer. All the tumour linear diameters as well as its volume were insignificantly higher in rural women. The ADC value of the cervical tumor was insignificantly lower, while ADC of lymphatic nodules was higher in rural women. Insignificant changes in tumour grade between both examined groups were found in histological, clinical and radiological examinations. Place of residence did not influence any clinical symptoms nor tumour volume and its ADC. Colporrhoea and colpodynia were insignificantly more often observed in urban women, while parametrium, urinary bladder and rectal infiltrations were more commonly seen in rural residents. Higher risk of lymphatic spread to the internal iliac and parametral lymphatic nodes was reporte[b]d in the rural community. Cervical cancer had similar morphology and growth pattern, regardless of the place of residence. However, a insignificantly larger tumour size among rural residents may suggest a higher incidence of lymphatic spread, probably as a result of less aaccess to modern health care.
Potential source identification for aerosol concentrations over a site in Northwestern India
NASA Astrophysics Data System (ADS)
Payra, Swagata; Kumar, Pramod; Verma, Sunita; Prakash, Divya; Soni, Manish
2016-03-01
The collocated measurements of aerosols size distribution (ASD) and aerosol optical thickness (AOT) are analyzed simultaneously using Grimm aerosol spectrometer and MICROTOP II Sunphotometer over Jaipur, capital of Rajasthan in India. The contrast temperature characteristics during winter and summer seasons of year 2011 are investigated in the present study. The total aerosol number concentration (TANC, 0.3-20 μm) during winter season was observed higher than in summer time and it was dominated by fine aerosol number concentration (FANC < 2 μm). Particles smaller than 0.8 μm (at aerodynamic size) constitute ~ 99% of all particles in winter and ~ 90% of particles in summer season. However, particles greater than 2 μm contribute ~ 3% and ~ 0.2% in summer and winter seasons respectively. The aerosols optical thickness shows nearly similar AOT values during summer and winter but corresponding low Angstrom Exponent (AE) values during summer than winter, respectively. In this work, Potential Source Contribution Function (PSCF) analysis is applied to identify locations of sources that influenced concentrations of aerosols over study area in two different seasons. PSCF analysis shows that the dust particles from Thar Desert contribute significantly to the coarse aerosol number concentration (CANC). Higher values of the PSCF in north from Jaipur showed the industrial areas in northern India to be the likely sources of fine particles. The variation in size distribution of aerosols during two seasons is clearly reflected in the log normal size distribution curves. The log normal size distribution curves reveals that the particle size less than 0.8 μm is the key contributor in winter for higher ANC.
Muikku, Maarit; Heikkinen, Tarja; Solatie, Dina; Vesterbacka, Pia
2011-11-01
A study to determine activity concentrations of (210)Pb and (210)Po in the urine of certain Finnish population groups was conducted, to investigate the variation in natural background level of urinary excretion. The study participants were divided into three groups mainly based on their diet. The first group comprised recreational fishermen and the second group represented people consuming more reindeer meat than an average Finn, while people using drinking water with very high activity concentrations of (210)Po were selected for the third group. The fourth group was a control group. The mean urinary excretion of (210)Po in groups 1 and 2 was 73 and 100 mBq d(-1), respectively. These values were higher than the value of the control group (20 mBq d(-1)) and the mean values reported in the literature. The mean daily urinary excretion of (210)Pb in groups 1 and 2, 70 and 52 mBq d(-1), was also slightly higher than that in the control group (32 mBq d(-1)). In contrast, the excretion rates of both (210)Po and (210)Pb for the members of group 3 were one to two orders of magnitude higher than those reported in the literature. This was clearly due to the elevated levels of natural radionuclides in their drinking water. The present study demonstrates the importance of possessing good knowledge of the background levels, in order to allow the determination of the additional exposure due, for example, to the malevolent use of radiation.
Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.
Liu, Yupin P; Song, Rui; Liang, Chang hong; Chen, Xin; Liu, Bo
2012-08-15
A multitude of evidence suggests that iodinated contrast material causes nephrotoxicity; however, there have been no previous studies that use arterial spin labeling (ASL) blood flow functional magnetic resonance imaging (fMRI) to investigate the alterations in effective renal plasma flow between normointensive and hypertensive rats following injection of contrast media. We hypothesized that FAIR-SSFSE arterial spin labeling MRI may enable noninvasive and quantitative assessment of regional renal blood flow abnormalities and correlate with disease severity as assessed by histological methods. Renal blood flow (RBF) values of the cortex and medulla of rat kidneys were obtained from ASL images postprocessed at ADW4.3 workstation 0.3, 24, 48, and 72 h before and after injection of iodinated contrast media (6 ml/kg). The H&E method for morphometric measurements was used to confirm the MRI findings. The RBF values of the outer medulla were lower than those of the cortex and the inner medulla as reported previously. Iodinated contrast media treatment resulted in decreases in RBF in the outer medulla and cortex in spontaneously hypertensive rats (SHR), but only in the outer medulla in normotensive rats. The iodinated contrast agent significantly decreased the RBF value in the outer medulla and the cortex in SHR compared with normotensive rats after injection of the iodinated contrast media. Histological observations of kidney morphology were also consistent with ASL perfusion changes. These results demonstrate that the RBF value can reflect changes of renal perfusion in the cortex and medulla. ASL-MRI is a feasible and accurate method for evaluating nephrotoxic drugs-induced kidney damage.
Denardo, Scott J; Vock, David M; Schmalfuss, Carsten M; Young, Gregory D; Tcheng, James E; O'Connor, Christopher M
2016-07-01
Contrast media administered during cardiac catheterization can affect hemodynamic variables. However, little is documented about the effects of contrast on hemodynamics in heart failure patients or the prognostic value of baseline and changes in hemodynamics for predicting subsequent adverse events. In this prospective study of 150 heart failure patients, we measured hemodynamics at baseline and after administration of iodixanol or iopamidol contrast. One-year Kaplan-Meier estimates of adverse event-free survival (death, heart failure hospitalization, and rehospitalization) were generated, grouping patients by baseline measures of pulmonary capillary wedge pressure (PCWP) and cardiac index (CI), and by changes in those measures after contrast administration. We used Cox proportional hazards modeling to assess sequentially adding baseline PCWP and change in CI to 5 validated risk models (Seattle Heart Failure Score, ESCAPE [Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness], CHARM [Candesartan in Heart Failure: Assessment of Reduction in Mortality and Morbidity], CORONA [Controlled Rosuvastatin Multinational Trial in Heart Failure], and MAGGIC [Meta-Analysis Global Group in Chronic Heart Failure]). Median contrast volume was 109 mL. Both contrast media caused similarly small but statistically significant changes in most hemodynamic variables. There were 39 adverse events (26.0%). Adverse event rates increased using the composite metric of baseline PCWP and change in CI (P<0.01); elevated baseline PCWP and decreased CI after contrast correlated with the poorest prognosis. Adding both baseline PCWP and change in CI to the 5 risk models universally improved their predictive value (P≤0.02). In heart failure patients, the administration of contrast causes small but significant changes in hemodynamics. Calculating baseline PCWP with change in CI after contrast predicts adverse events and increases the predictive value of existing models. Patients with elevated baseline PCWP and decreased CI after contrast merit greatest concern. © 2016 American Heart Association, Inc.
[Optimal beam quality for chest digital radiography].
Oda, Nobuhiro; Tabata, Yoshito; Nakano, Tsutomu
2014-11-01
To investigate the optimal beam quality for chest computed radiography (CR), we measured the radiographic contrast and evaluated the image quality of chest CR using various X-ray tube voltages. The contrast between lung and rib or heart increased on CR images obtained by lowering the tube voltage from 140 to 60 kV, but the degree of increase was less. Scattered radiation was reduced on CR images with a lower tube voltage. The Wiener spectrum of CR images with a low tube voltage showed a low value under identical conditions of amount of light stimulated emission. The quality of chest CR images obtained using a lower tube voltage (80 kV and 100 kV) was evaluated as being superior to those obtained with a higher tube voltage (120 kV and 140 kV). Considering the problem of tube loading and exposure in clinical applications, a tube voltage of 90 to 100 kV (0.1 mm copper filter backed by 0.5 mm aluminum) is recommended for chest CR.
NASA Astrophysics Data System (ADS)
Reitan, Nina Kristine; Thuen, Marte; Goa, Pa˚L. Erik; de Lange Davies, Catharina
2010-05-01
Solid tumors are characterized by abnormal blood vessel organization, structure, and function. These abnormalities give rise to enhanced vascular permeability and may predict therapeutic responses. The permeability and architecture of the microvasculature in human osteosarcoma tumors growing in dorsal window chambers in athymic mice were measured by confocal laser scanning microscopy (CLSM) and dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). Dextran (40 kDa) and Gadomer were used as molecular tracers for CLSM and DCE-MRI, respectively. A significant correlation was found between permeability indicators. The extravasation rate Ki as measured by CLSM correlated positively with DCE-MRI parameters, such as the volume transfer constant Ktrans and the initial slope of the contrast agent concentration-time curve. This demonstrates that these two techniques give complementary information. Extravasation was further related to microvascular structure and was found to correlate with the fractal dimension and vascular density. The structural parameter values that were obtained from CLSM images were higher for abnormal tumor vasculature than for normal vessels.
NASA Astrophysics Data System (ADS)
Li, Ming-Lung; Wang, Yi-Chou; Liou, Tong-Miin; Lin, Chao-An
2014-10-01
Precise locations of rupture region under contrast agent leakage of five ruptured cerebral artery aneurysms during computed tomography angiography, which is to our knowledge for the first time, were successfully identified among 101 patients. These, together with numerical simulations based on the reconstructed aneurysmal models, were used to analyze hemodynamic parameters of aneurysms under different cardiac cyclic flow rates. For side wall type aneurysms, different inlet flow rates have mild influences on the shear stresses distributions. On the other hand, for branch type aneurysms, the predicted wall shear stress (WSS) correlates strongly with the increase of inlet vessel velocity. The mean and time averaged WSSes at rupture regions are found to be lower than those over the surface of the aneurysms. Also, the levels of the oscillatory shear index (OSI) are higher than the reported threshold value, supporting the assertion that high OSI correlates with rupture of the aneurysm. However, the present results also indicate that OSI level at the rupture region is relatively lower.
Kieper, Douglas Arthur [Seattle, WA; Majewski, Stanislaw [Morgantown, WV; Welch, Benjamin L [Hampton, VA
2012-07-03
An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.
Kieper, Douglas Arthur [Newport News, VA; Majewski, Stanislaw [Yorktown, VA; Welch, Benjamin L [Hampton, VA
2008-10-28
An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.
Rudebeck, Peter H; Murray, Elisabeth A
2011-12-01
The primate orbitofrontal cortex (OFC) is often treated as a single entity, but architectonic and connectional neuroanatomy indicate that it has distinguishable parts. Nevertheless, few studies have attempted to dissociate the functions of its subregions. Here we review findings from recent neuropsychological and neurophysiological studies that do so. The lateral OFC seems to be important for learning, representing, and updating specific object-reward associations. The medial OFC seems to be important for value comparisons and choosing among objects on that basis. Rather than viewing this dissociation of function in terms of learning versus choosing, however, we suggest that it reflects the distinction between contrasts and comparisons: differences versus similarities. Making use of high-dimensional representations that arise from the convergence of several sensory modalities, the lateral OFC encodes contrasts among outcomes. The medial OFC reduces these contrasting representations of value to a single dimension, a common currency, in order to compare alternative choices. © 2011 New York Academy of Sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diaz, Alfredo J.; Eslami, Babak; López-Guerra, Enrique A.
2014-09-14
This paper explores the effect of the amplitude ratio of the higher to the fundamental eigenmode in bimodal atomic force microscopy (AFM) on the phase contrast and the dissipated power contrast of the higher eigenmode. We explore the optimization of the amplitude ratio in order to maximize the type of contrast that is most relevant to the particular study. Specifically, we show that the trends in the contrast range behave differently for different quantities, especially the dissipated power and the phase, with the former being more meaningful than the latter (a similar analysis can be carried out using the virial,more » for which we also provide a brief example). Our work is based on numerical simulations using two different conservative-dissipative tip-sample models, including the standard linear solid and the combination of a dissipation coefficient with a conservative model, as well as experimental images of thin film Nafion{sup ®} proton exchange polymers. We focus on the original bimodal AFM method, where the higher eigenmode is driven with constant amplitude and frequency (i.e., in “open loop”).« less
In Search of the Optimal Heart Perfusion Ultrasound Imaging Platform.
Grishenkov, Dmitry; Gonon, Adrian; Janerot-Sjoberg, Birgitta
2015-09-01
Quantification of myocardial perfusion by contrast echocardiography remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled. To contribute toward an improvement, we developed a contrast echocardiographic perfusion imaging platform based on an isolated rat heart coupled to an ultrasound scanner. Perfusion was assessed by using 3 different types of contrast agents: dextran-based Promiten (Meda AB, Solna, Sweden), phospholipid-shelled SonoVue (Bracco Diagnostics, Inc, Princeton, NJ), and polymer-shelled MB-pH5-RT, developed in-house. The myocardial video intensity was monitored over time from contrast agent administration to peak, and 2 characteristic constants were calculated by using an exponential fit: A, representing capillary volume; and β, representing inflow velocity. Acquired experimental evidence demonstrates that the application of all 3 contrast agents allows sonographic estimation of myocardial perfusion in the isolated rat heart. Video intensity maps show that an increase in contrast concentration increases the late-plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to A × β, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by a flowmeter attached to the aortic cannula. The contrast echocardiographic perfusion imaging platform described holds promise for standardized evaluation and optimization of contrast perfusion ultrasound imaging in which real-time inflow curves at low acoustic power semiquantitatively reflect coronary flow. © 2015 by the American Institute of Ultrasound in Medicine.
Scheidler, J; Heuck, A; Wencke, K; Kimmig, R; Müller-Lisse, U; Reiser, M
1997-04-01
To determine whether contrast-enhanced and fat-suppressed sequences contribute to the MR imaging diagnosis of parametrial invasion. 21 patients with carcinoma of the cervix were prospectively examined with a phased-array coil and a 1.5T MR-scanner using the following sequences: transverse T2-weighted turbo spin echo (T2-TSE), T1-weighted spin echo (T1-SE) and fat suppressed T1-weighted SE sequences before and after Gd-DTPA. The sequences were evaluated separately for the presence of parametrial invasion. Image quality and diagnostic confidence were classified on a scale of 0-10 (nondiagnostic-excellent). Findings were compared to the results of the pathohistological examination. Sensitivity, specificity and diagnostic accuracy were highest for T2-TSE sequences (100%, 79% and 86%, respectively). Contrast-enhanced T1-SE sequences with fat-suppression (71%, 79%, and 76%) showed no improvement compared to T2-TSE. Unenhanced fat-suppressed T1-SE (100%, 30%, and 56%) and unenhanced T1-SE (100%, 7%, and 38%) as well as contrast-enhanced T1-SE (86%, 20%, and 47%) were significantly worse than T2-TSE. With similar image quality (p < 0.05) diagnostic confidence was higher on T2-TSE than on any of the other sequences (p < 0.001). Considering the cost-effectiveness of the examination, for the MR diagnosis of parametrial invasion the use of fat-suppressed contrast-enhanced sequences can be abandoned in favour of T2-weighted TSE sequences.
Oxidative stress and kidney injury in trans-radial catheterization.
Tsarouhas, Konstantinos; Tsitsimpikou, Christina; Papantoni, Xrisoula; Lazaridou, Dimitra; Koutouzis, Michael; Mazzaris, Savvas; Rezaee, Ramin; Mamoulakis, Charalambos; Georgoulias, Panagiotis; Nepka, Charitini; Rentoukas, Elias; Kyriakides, Zenon; Tsatsakis, Aristidis; Spandidos, Demetrios A; Kouretas, Demetrios
2018-05-01
Oxidative stress is linked to coronary artery disease and is a major mechanism in contrast-induced nephropathy. Trans-radial approach in coronary angiography (CA) with minimized peri-procedural bleeding is expected to reduce acute kidney injury incidence. In the present study, oxidative stress patterns observed in radial CA and their associations with early manifestations of kidney injury are described. A total of 20 stable coronary disease patients submitted to CA and 17 sex-matched patients undergoing computed tomography for myoskeletal reasons were enrolled. Reduced glutathione, catalase, thiobarbituric acid reactive species (TBARS) levels and total anti-oxidant status were measured at various time points postangiography. In ischemic patients baseline TBARS levels were 2-fold lower compared to controls, while carbonyls levels were 35% higher. Glutathione was almost 4-fold lower than the control group. Glutathione and lipid peroxidation in ischemic patients gradually increased after contrast medium administration and reached 180% (P<0.001) and 20% (P=0.021) after 4-6 h, respectively. Four patients presented early evidence of contrast-induced nephropathy postangiography, while no control patient developed acute kidney injury. In the multiple logistic regression analysis, only the creatinine levels at baseline influenced the frequency of early contrast-induced nephropathy development (β =0.36, 95% CI: 0.285-0.438, P=0.01). Glutathione low levels were dominant in the baseline values of ischemic patients who developed contrast-induced nephropathy. Glutathione levels rapidly increased while protein oxidation decreased at the expense of lipid peroxidation. In conclusion, early oxidative stress changes occur in trans-radial CA patients with a mild profile, sufficient to mobilize patient antioxidant defenses.
Phase-contrast Hounsfield units of fixated and non-fixated soft-tissue samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willner, Marian; Fior, Gabriel; Marschner, Mathias
X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissuemore » specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. In addition, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results.« less
NASA Astrophysics Data System (ADS)
Stoyanov, Stiliyan; Mardirossian, Garo
2012-10-01
The light diffraction is for telescope apparatuses an especially important characteristic which has an influence on the record image contrast from the eye observer. The task of the investigation is to determine to what degree the coefficient of light diffraction influences the record image brightness. The object of the theoretical research are experimental results provided from a telescope system experiment in the process of observation of remote objects with different brightness of the background in the fixed light diffraction coefficients and permanent contrast of the background in respect to the object. The received values and the ratio of the image contrast to the light diffraction coefficient is shown in a graphic view. It's settled that with increasing of the value of background brightness in permanent background contrast in respect to the object, the image contrast sharply decrease. The relationship between the increase of the light diffraction coefficient and the decrease of the brightness of the project image from telescope apparatuses can be observed.
Phase-Contrast Hounsfield Units of Fixated and Non-Fixated Soft-Tissue Samples
Willner, Marian; Fior, Gabriel; Marschner, Mathias; Birnbacher, Lorenz; Schock, Jonathan; Braun, Christian; Fingerle, Alexander A.; Noël, Peter B.; Rummeny, Ernst J.; Pfeiffer, Franz; Herzen, Julia
2015-01-01
X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissue specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. Furthermore, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results. PMID:26322638
Phase-contrast Hounsfield units of fixated and non-fixated soft-tissue samples
Willner, Marian; Fior, Gabriel; Marschner, Mathias; ...
2015-08-31
X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissuemore » specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. In addition, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results.« less
NASA Astrophysics Data System (ADS)
Sims, M.; Tuladhar, S. M.; Nelson, J.; Maher, R. C.; Campoy-Quiles, M.; Choulis, S. A.; Mairy, M.; Bradley, D. D. C.; Etchegoin, P. G.; Tregidgo, C.; Suhling, K.; Richards, D. R.; Massiot, P.; Nielsen, C. B.; Steinke, J. H. G.
2007-11-01
We report a study of thin films of poly(2,5-dimethoxy- p -phenylenevinylene) (PDMeOPV) prepared by a precursor route. Conversion at two different temperatures, namely, 120 and 185°C , produces partially and fully converted films. We study the structural, optical, and charge transport characteristics of these samples in order to relate transport properties to microstructure. Micro-Raman mapping and photoluminescence (PL) imaging reveal the existence of coarse, depth-averaged domains of around 50μm in lateral extent, with more pronounced contrast for conversion at the higher temperature. The contrast in both micro-Raman and PL maps can be attributed to fluctuations in film density. Spectroscopic ellipsometry studies of the films indicate that the average film density is approximately 15% higher for conversion at the higher temperature. Time-of-flight photocurrent transients, recorded here in PDMeOPV films, are typically dispersive but yield hole mobilities in excess of 10-4cm2/Vs at modest applied fields (˜1.2×105V/cm) in the fully converted films. To our knowledge, these are amongst the highest reported mobility values for a poly( p -phenylenevinylene) derivative. Fully converted films, while yielding higher hole mobilities, exhibit a stronger dependence on electric field than partially converted ones. The higher mobility can be attributed to the almost complete conversion of the flexible saturated subunits within precursor chains to conjugated vinylene moieties at elevated temperature. This results in a correspondingly higher packing density, an improvement in intrachain transport, and a reduction in the smallest interchain hopping distance. We suggest that the stronger electric field dependence is due to the increasing influence of intermolecular electrostatic interactions with decreasing interchain separation. We propose that a greater proportion of chains in the fully converted films packs in a three-dimensional, interdigitated arrangement similar to that described previously for crystalline samples of PDMeOPV [J. H. F. Martens , Synth. Met. 55, 449 (1993)].
Figure-ground segregation by motion contrast and by luminance contrast.
Regan, D; Beverley, K I
1984-05-01
Some naturally camouflaged objects are invisible unless they move; their boundaries are then defined by motion contrast between object and background. We compared the visual detection of such camouflaged objects with the detection of objects whose boundaries were defined by luminance contrast. The summation field area is 0.16 deg2 , and the summation time constant is 750 msec for parafoveally viewed objects whose boundaries are defined by motion contrast; these values are, respectively, about 5 and 12 times larger than the corresponding values for objects defined by luminance contrast. The log detection threshold is proportional to the eccentricity for a camouflaged object of constant area. The effect of eccentricity on threshold is less for large objects than for small objects. The log summation field diameter for detecting camouflaged objects is roughly proportional to the eccentricity, increasing to about 20 deg at 32-deg eccentricity. In contrast to the 100:1 increase of summation area for detecting camouflaged objects, the temporal summation time constant changes by only 40% between eccentricities of 0 and 16 deg.
Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography.
Miura, Hideharu; Ozawa, Shuichi; Okazue, Toshiya; Kawakubo, Atsushi; Yamada, Kiyoshi; Nagata, Yasushi
2018-05-01
Dual-source cone-beam computed tomography (DCBCT) is currently available in the Vero4DRT image-guided radiotherapy system. We evaluated the image quality and absorbed dose for DCBCT and compared the values with those for single-source CBCT (SCBCT). Image uniformity, Hounsfield unit (HU) linearity, image contrast, and spatial resolution were evaluated using a Catphan phantom. The rotation angle for acquiring SCBCT and DCBCT images is 215° and 115°, respectively. The image uniformity was calculated using measurements obtained at the center and four peripheral positions. The HUs of seven materials inserted into the phantom were measured to evaluate HU linearity and image contrast. The Catphan phantom was scanned with a conventional CT scanner to measure the reference HU for each material. The spatial resolution was calculated using high-resolution pattern modules. Image quality was analyzed using ImageJ software ver. 1.49. The absorbed dose was measured using a 0.6-cm 3 ionization chamber with a 16-cm-diameter cylindrical phantom, at the center and four peripheral positions of the phantom, and calculated using weighted cone-beam CT dose index (CBCTDI w ). Compared with that of SCBCT, the image uniformity of DCBCT was slightly reduced. A strong linear correlation existed between the measured HU for DCBCT and the reference HU, although the linear regression slope was different from that of the reference HU. DCBCT had poorer image contrast than did SCBCT, particularly with a high-contrast material. There was no significant difference between the spatial resolutions of SCBCT and DCBCT. The absorbed dose for DCBCT was higher than that for SCBCT, because in DCBCT, the two x-ray projections overlap between 45° and 70°. We found that the image quality was poorer and the absorbed dose was higher for DCBCT than for SCBCT in the Vero4DRT. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Ausländische Direktinvestitionen - bleibt die Sozialpartnerschaft auf der Strecke?
NASA Astrophysics Data System (ADS)
Jansen, Peter; Weingarten, Jörg
2017-04-01
Germany attracts ever higher levels of foreign direct investment. This raises the question how these investments affect labour relations, which in this country are characterized by a high importance of co-determination and social partnership. Foreign investors are often perceived as a threat, amongst other things, for co-determination or the rights of the workforce. There is also empirical evidence that points to a negative impact of foreign direct investment on the social partnership model. In contrast, other studies conclude that foreign investors value co-determination. Correspondingly, it is not plausible to consider foreign direct investment generally as threat for the social partnership model.
Cascade of Magnetic Field Induced Spin Transitions in LaCoO3
NASA Astrophysics Data System (ADS)
Altarawneh, M. M.; Chern, G.-W.; Harrison, N.; Batista, C. D.; Uchida, A.; Jaime, M.; Rickel, D. G.; Crooker, S. A.; Mielke, C. H.; Betts, J. B.; Mitchell, J. F.; Hoch, M. J. R.
2012-07-01
We present magnetization and magnetostriction studies of LaCoO3 in magnetic fields approaching 100 T. In contrast with expectations from single-ion models, the data reveal two distinct first-order transitions and well-defined magnetization plateaus. The magnetization at the higher plateau is only about half the saturation value expected for spin-1 Co3+ ions. These findings strongly suggest collective behavior induced by interactions between different electronic configurations of Co3+ ions. We propose a model that predicts crystalline spin textures and a cascade of four magnetic phase transitions at high fields, of which the first two account for the experimental data.
A contrast enhancement method for improving the segmentation of breast lesions on ultrasonography.
Flores, Wilfrido Gómez; Pereira, Wagner Coelho de Albuquerque
2017-01-01
This paper presents an adaptive contrast enhancement method based on sigmoidal mapping function (SACE) used for improving the computerized segmentation of breast lesions on ultrasound. First, from the original ultrasound image an intensity variation map is obtained, which is used to generate local sigmoidal mapping functions related to distinct contextual regions. Then, a bilinear interpolation scheme is used to transform every original pixel to a new gray level value. Also, four contrast enhancement techniques widely used in breast ultrasound enhancement are implemented: histogram equalization (HEQ), contrast limited adaptive histogram equalization (CLAHE), fuzzy enhancement (FEN), and sigmoid based enhancement (SEN). In addition, these contrast enhancement techniques are considered in a computerized lesion segmentation scheme based on watershed transformation. The performance comparison among techniques is assessed in terms of both the quality of contrast enhancement and the segmentation accuracy. The former is quantified by the measure, where the greater the value, the better the contrast enhancement, whereas the latter is calculated by the Jaccard index, which should tend towards unity to indicate adequate segmentation. The experiments consider a data set with 500 breast ultrasound images. The results show that SACE outperforms its counterparts, where the median values for the measure are: SACE: 139.4, SEN: 68.2, HEQ: 64.1, CLAHE: 62.8, and FEN: 7.9. Considering the segmentation performance results, the SACE method presents the largest accuracy, where the median values for the Jaccard index are: SACE: 0.81, FEN: 0.80, CLAHE: 0.79, HEQ: 77, and SEN: 0.63. The SACE method performs well due to the combination of three elements: (1) the intensity variation map reduces intensity variations that could distort the real response of the mapping function, (2) the sigmoidal mapping function enhances the gray level range where the transition between lesion and background is found, and (3) the adaptive enhancing scheme for coping with local contrasts. Hence, the SACE approach is appropriate for enhancing contrast before computerized lesion segmentation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging
NASA Astrophysics Data System (ADS)
Willner, M.; Herzen, J.; Grandl, S.; Auweter, S.; Mayr, D.; Hipp, A.; Chabior, M.; Sarapata, A.; Achterhold, K.; Zanette, I.; Weitkamp, T.; Sztrókay, A.; Hellerhoff, K.; Reiser, M.; Pfeiffer, F.
2014-04-01
X-ray phase-contrast imaging has received growing interest in recent years due to its high capability in visualizing soft tissue. Breast imaging became the focus of particular attention as it is considered the most promising candidate for a first clinical application of this contrast modality. In this study, we investigate quantitative breast tissue characterization using grating-based phase-contrast computed tomography (CT) at conventional polychromatic x-ray sources. Different breast specimens have been scanned at a laboratory phase-contrast imaging setup and were correlated to histopathology. Ascertained tumor types include phylloides tumor, fibroadenoma and infiltrating lobular carcinoma. Identified tissue types comprising adipose, fibroglandular and tumor tissue have been analyzed in terms of phase-contrast Hounsfield units and are compared to high-quality, high-resolution data obtained with monochromatic synchrotron radiation, as well as calculated values based on tabulated tissue properties. The results give a good impression of the method’s prospects and limitations for potential tumor detection and the associated demands on such a phase-contrast breast CT system. Furthermore, the evaluated quantitative tissue values serve as a reference for simulations and the design of dedicated phantoms for phase-contrast mammography.
Coordination strategies of chimpanzees and human children in a Stag Hunt game
Duguid, Shona; Wyman, Emily; Bullinger, Anke F.; Herfurth-Majstorovic, Katharina; Tomasello, Michael
2014-01-01
Much of human cooperation takes place in mutualistic contexts in which the main challenge for individuals is how to coordinate decisions. In the current studies, we compared the abilities of chimpanzees and young children to coordinate with a partner in two versions of a Stag Hunt game. When risks were low (the hare was of low value) and information was cheap (the partner's behaviour was readily observable), partners of both species were able to successfully coordinate on the higher value stag more than 90% of the time. By contrast, when the risks were raised and observing the partner was more difficult, the chimpanzees became less successful, whereas the children compensated, and so remained highly successful, by communicating more often and more specifically. This pattern of results is consistent with the hypothesis that humans evolved unique skills of coordination and communication in the context of especially risky coordination problems. PMID:25320165
Bluffing promotes overconfidence on social networks
NASA Astrophysics Data System (ADS)
Li, Kun; Cong, Rui; Wu, Te; Wang, Long
2014-06-01
The overconfidence, a well-established bias, in fact leads to unrealistic expectations or faulty assessment. So it remains puzzling why such psychology of self-deception is stabilized in human society. To investigate this problem, we draw lessons from evolutionary game theory which provides a theoretical framework to address the subtleties of cooperation among selfish individuals. Here we propose a spatial resource competition model showing that, counter-intuitively, moderate values rather than large values of resource-to-cost ratio boost overconfidence level most effectively. In contrast to theoretical results in infinite well-mixed populations, network plays a role both as a ``catalyst'' and a ``depressant'' in the spreading of overconfidence, especially when resource-to-cost ratio is in a certain range. Moreover, when bluffing is taken into consideration, overconfidence evolves to a higher level to counteract its detrimental effect, which may well explain the prosperity of this ``erroneous'' psychology.
Parallel bulk heterojunction photovoltaics based on all-conjugated block copolymer additives
Mok, Jorge W.; Kipp, Dylan; Hasbun, Luis R.; ...
2016-08-23
We demonstrated that the addition of block copolymers to binary donor–acceptor blends represents an effective approach to target equilibrium, co-continuous morphologies of interpenetrating donors and acceptors in our recent study. We report a study of the impact of all-conjugated poly(thieno[3,4-b]-thiophene-co-benzodithiophene)-b-polynaphthalene diimide (PTB7-b-PNDI) block copolymer additives on the electronic properties and photovoltaic performance of bulk heterojunction organic photovoltaic active layers comprised of a PTB7 donor and a phenyl-C61-butyric acid methyl ester (PCBM61) acceptor. We find that small amounts of BCP additives lead to improved performance due to a large increase in the device open-circuit voltage (VOC), and the VOC is pinnedmore » to this higher value for higher BCP additive loadings. Such results contrast prior studies of ternary blend OPVs where either a continuous change in VOC or a value of VOC pinned to the lowest value is observed. We hypothesize and provide evidence in the form of device and morphology analyses that the impact of VOC is likely due to the formation of a parallel bulk heterojunction made up of isolated PCBM and PNDI acceptor domains separated by intermediate PTB7 donor domains. Our work demonstrates that all-conjugated block copolymers can be utilized as additives to both dictate morphology and modulate the electronic properties of the active layer.« less
Plasma catecholamine metabolites in schizophrenics: evidence for the two-subtype concept.
Chang, W H; Chen, T Y; Lin, S K; Lung, F W; Lin, W L; Hu, W H; Yeh, E K
1990-03-01
Plasma homovanillic acid (pHVA) and plasma methoxyhydroxyphenyl glycol (pMHPG), as well as plasma haloperidol, were measured in 33 schizophrenic patients before and during 6 weeks of haloperidol treatment. Good responders had higher baseline pHVA values compared with poor responders (17.4 +/- 8.8 ng/ml, n = 22 versus 11.4 +/- 5.0 ng/ml, n = 11, p less than 0.05). A higher than 15 ng/ml pretreatment pHVA level was associated with a more consistent clinical response to the subsequent treatment. Differential pHVA changes during treatment were also found between good and poor responders. Within the good responder group, a significant decline in pHVA over time was found. By contrast, pHVA showed a transient increase in the poor responder group. Plasma MHPG changes showed a similar pattern during treatment in good responders, although no significant differences in baseline values were found between the good (n = 13) and poor (n = 9) responders, and pMHPG showed no change during treatment in poor responders. Significant correlations between baseline pHVA and pMHPG values were found in 22 patients. Good responders and poor responders did not differ significantly in terms of age, duration of illness, severity of presenting symptoms, haloperidol dose, or plasma drug concentration. Two hypothetical subtypes of schizophrenia and both dopamine and norepinephrine systems involved in schizophrenic psychopathology are proposed.
Parallel bulk heterojunction photovoltaics based on all-conjugated block copolymer additives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mok, Jorge W.; Kipp, Dylan; Hasbun, Luis R.
We demonstrated that the addition of block copolymers to binary donor–acceptor blends represents an effective approach to target equilibrium, co-continuous morphologies of interpenetrating donors and acceptors in our recent study. We report a study of the impact of all-conjugated poly(thieno[3,4-b]-thiophene-co-benzodithiophene)-b-polynaphthalene diimide (PTB7-b-PNDI) block copolymer additives on the electronic properties and photovoltaic performance of bulk heterojunction organic photovoltaic active layers comprised of a PTB7 donor and a phenyl-C61-butyric acid methyl ester (PCBM61) acceptor. We find that small amounts of BCP additives lead to improved performance due to a large increase in the device open-circuit voltage (VOC), and the VOC is pinnedmore » to this higher value for higher BCP additive loadings. Such results contrast prior studies of ternary blend OPVs where either a continuous change in VOC or a value of VOC pinned to the lowest value is observed. We hypothesize and provide evidence in the form of device and morphology analyses that the impact of VOC is likely due to the formation of a parallel bulk heterojunction made up of isolated PCBM and PNDI acceptor domains separated by intermediate PTB7 donor domains. Our work demonstrates that all-conjugated block copolymers can be utilized as additives to both dictate morphology and modulate the electronic properties of the active layer.« less
Widespread Anthropogenic Nitrogen in Northwestern Pacific Ocean Sediment.
Kim, Haryun; Lee, Kitack; Lim, Dhong-Il; Nam, Seung-Il; Kim, Tae-Wook; Yang, Jin-Yu T; Ko, Young Ho; Shin, Kyung-Hoon; Lee, Eunil
2017-06-06
Sediment samples from the East China and Yellow seas collected adjacent to continental China were found to have lower δ 15 N values (expressed as δ 15 N = [ 15 N: 14 N sample / 15 N: 14 N air - 1] × 1000‰; the sediment 15 N: 14 N ratio relative to the air nitrogen 15 N: 14 N ratio). In contrast, the Arctic sediments from the Chukchi Sea, the sampling region furthest from China, showed higher δ 15 N values (2-3‰ higher than those representing the East China and the Yellow sea sediments). Across the sites sampled, the levels of sediment δ 15 N increased with increasing distance from China, which is broadly consistent with the decreasing influence of anthropogenic nitrogen (N ANTH ) resulting from fossil fuel combustion and fertilizer use. We concluded that, of several processes, the input of N ANTH appears to be emerging as a new driver of change in the sediment δ 15 N value in marginal seas adjacent to China. The present results indicate that the effect of N ANTH has extended beyond the ocean water column into the deep sedimentary environment, presumably via biological assimilation of N ANTH followed by deposition. Further, the findings indicate that N ANTH is taking over from the conventional paradigm of nitrate flux from nitrate-rich deep water as the primary driver of biological export production in this region of the Pacific Ocean.
General and food-specific parenting: measures and interplay.
Kremers, Stef; Sleddens, Ester; Gerards, Sanne; Gubbels, Jessica; Rodenburg, Gerda; Gevers, Dorus; van Assema, Patricia
2013-08-01
Parental influence on child food intake is typically conceptualized at three levels-parenting practices, feeding style, and parenting style. General parenting style is modeled at the most distal level of influence and food parenting practices are conceptualized as the most proximal level of influence. The goal of this article is to provide insights into contents and explanatory value of instruments that have been applied to assess food parenting practices, feeding style, and parenting style. Measures of food parenting practices, feeding style, and parenting style were reviewed, compared, and contrasted with regard to contents, explanatory value, and interrelationships. Measures that are used in the field often fail to cover the full scope and complexity of food parenting. Healthy parenting dimensions have generally been found to be positively associated with child food intake (i.e., healthier dietary intake and less intake of energy-dense food products and sugar-sweetened beverages), but effect sizes are low. Evidence for the operation of higher-order moderation has been found, in which the impact of proximal parental influences is moderated by more distal levels of parenting. Operationalizing parenting at different levels, while applying a contextual higher-order moderation approach, is advocated to have surplus value in understanding the complex process of parent-child interactions in the area of food intake. A research paradigm is presented that may guide future work regarding the conceptualization and modeling of parental influences on child dietary behavior.
Stay-green traits to improve wheat adaptation in well-watered and water-limited environments
Christopher, John.T.; Christopher, Mandy J.; Borrell, Andrew K.; Fletcher, Susan; Chenu, Karine
2016-01-01
A stay-green phenotype enables crops to retain green leaves longer after anthesis compared with senescent types, potentially improving yield. Measuring the normalized difference vegetative index (NDVI) during the whole senescence period allows quantification of component stay-green traits contributing to a stay-green phenotype. These objective and standardized traits can be compared across genotypes and environments. Traits examined include maximum NDVI near anthesis (Nmax), senescence rate (SR), a trait integrating senescence (SGint), plus time from anthesis to onset (OnS), mid-point (MidS), and near completion (EndS) of senescence. The correlation between stay-green traits and yield was studied in eight contrasting environments ranging from well watered to severely water limited. Environments were each classified into one of the four major drought environment types (ETs) previously identified for the Australian wheat cropping system. SGint, OnS, and MidS tended to have higher values in higher yielding environments for a given genotype, as well as for higher yielding genotypes within a given environment. Correlation between specific stay-green traits and yield varied with ET. In the studied population, SGint, OnS, and MidS strongly correlated with yield in three of the four ETs which included well-watered environments (0.43–0.86), but less so in environments with only moderate water-stress after anthesis (−0.03 to 0.31). In contrast, Nmax was most highly correlated with yield under moderate post-anthesis water stress (0.31–0.43). Selection for particular stay-green traits, combinations of traits, and/or molecular markers associated with the traits could enhance genetic progress toward stay-green wheats with higher, more stable yield in both well-watered and water-limited conditions. PMID:27443279
Chatterjee, Nabamita; Nagarajan, Shantha
2006-08-01
The relative binding of seed water and seed coat membrane stability were measured in two contrasting wheat (Triticum aestivum L) varieties, HDR 77 (drought-tolerant) and HD 2009 (susceptible) using seed water sorption isotherms, electrical conductivity (EC) of leachates and desorption-absorption isotherms. Analysis of sorption isotherm at 25 degrees C showed that the seeds of HDR 77 had significantly higher number of strong binding sites, with correspondingly greater amount of seed water as strongly bound water, as compared to HD 2009. Total number of binding sites was also higher in HDR 77 than HD 2009, which explained the better desiccation tolerance and higher capacity to bind water in seeds of HDR 77. EC of seed leachate in both varieties did not change with respect to change in equilibrium relative humidity (RII), indicating the general seed coat membrane stability of wheat seeds. However, absolute conductivity values were higher for HD 2009. showing its relatively porous seed coat membrane. Significantly lower area enclosed by the desorption-absorption isotherm loop in HDR 77, as compared to HD 2009 also indicated the greater membrane integrity of HDR 77. Germination and seedling vigour of HD 2009 were reduced when equilibrated over very low and very high RH. In contrast, germination and vigour in HDR 77 were maintained high, except at very high RH, indicating again its desiccation tolerance. Thus, the study demonstrated the relative drought tolerance of HDR 77, on the basis of seed water-binding characteristics and seed membrane stability. Seed membrane stability as measured by seed leachate conductivity or as area under dehydration-rehydration loop may be used as a preliminary screening test for drought tolerance in wheat.
Engelke, W; Grossniklaus, B; Sailer, H F
1991-01-01
Double contrast arthrotomography combined with cinematography as a diagnostic instrument establishing functional and structural TMJ alterations is evaluated for its diagnostic value and reliability within the chain of diagnostic measures applied. In 131 patients double-contrast arthrotomography was followed by a comprehensive history of joint problems, and verification of the clinical findings as well as the arthrographic diagnosis and the post-arthrographic TMJ alterations. Our interest was focussed, among others, on the question whether arthrography alone would have any therapeutic effect or produce an alteration in TMJ function.
Zhang, Limin; Jiang, Shudong; Zhao, Yan; Feng, Jinchao; Pogue, Brian W; Paulsen, Keith D
2018-05-01
An approach using direct regularization from co-registered dynamic contrast enhanced magnetic reson- ance images was used to reconstruct near-infrared spectral tomography patient images, which does not need image segmentation. 20 patients with mammography/ultrasound confirmed breast abnormalities were involved in this paper, and the resulting images indicated that tumor total hemoglobin concentration contrast differentiated malignant from benign cases (p-value = 0.021). The approach prod- uced reconstructed images, which significantly reduced surface artifacts near the source-detector locations (p-value = 4.16e-6).
Integrated Fe- and S-isotope study of seafloor hydrothermal vents at East Pacific Rise 9-10°N
Rouxel, O.; Shanks, Wayne C.; Bach, W.; Edwards, K.J.
2008-01-01
In this study, we report on coupled Fe- and S-isotope systematics of hydrothermal fluids and sulfide deposits from the East Pacific Rise at 9–10°N to better constrain processes affecting Fe-isotope fractionation in hydrothermal environments. We aim to address three fundamental questions: (1) Is there significant Fe-isotope fractionation during sulfide precipitation? (2) Is there significant variability of Fe-isotope composition of the hydrothermal fluids reflecting sulfide precipitation in subsurface environments? (3) Are there any systematics between Fe- and S-isotopes in sulfide minerals? The results show that chalcopyrite, precipitating in the interior wall of a hydrothermal chimney displays a limited range of δ56Fe values and δ34S values, between − 0.11 to − 0.33‰ and 2.2 to 2.6‰ respectively. The δ56Fe values are, on average, slightly higher by 0.14‰ relative to coeval vent fluid composition while δ34S values suggest significant S-isotope fractionation (− 0.6 ± 0.2‰) during chalcopyrite precipitation. In contrast, systematically lower δ56Fe and δ34S values relative to hydrothermal fluids, by up to 0.91‰ and 2.0‰ respectively, are observed in pyrite and marcasite precipitating in the interior of active chimneys. These results suggest isotope disequilibrium in both Fe- and S-isotopes due to S-isotopic exchange between hydrothermal H2S and seawater SO42− followed by rapid formation of pyrite from FeS precursors, thus preserving the effects of a strong kinetic Fe-isotope fractionation during FeS precipitation. In contrast, δ56Fe and δ34S values of pyrite from inactive massive sulfides, which show evidence of extensive late-stage reworking, are essentially similar to the hydrothermal fluids. Multiple stages of remineralization of ancient chimney deposits at the seafloor appear to produce minimal Fe-isotope fractionation. Similar affects are indicated during subsurface sulfide precipitation as demonstrated by the lack of systematic differences between δ56Fe values in both high-temperature, Fe-rich black smokers and lower-temperature, Fe-depleted vents.
Mechanical properties of dust collected by dust separators in iron ore sinter plants.
Lanzerstorfer, Christof
2015-01-01
The flow-related mechanical properties of dusts from the de-dusting systems of several sinter plants were investigated. The mass median diameters of the dusts were in the range from approximately 3 to 100 µm. Also, the bulk density of the dusts varied in a wide range (approximately 400 to 2300 kg/m³). A good correlation between the bulk density and the mass median diameter for most of the dusts was found. In contrast, the angles of repose did not vary very much, only for the coarsest dust a significantly lower value was measured. The angles of internal friction as well as the wall friction angles were lower for coarse dust and higher for fine dust. The shear tests showed that both angles depend considerably on the stress level. At low stress, the angles decreased significantly with increasing values of stress, whereas at higher stress, the dependence was small or even disappeared. The only exception to this behaviour was shown by the finest dust. The flowability decreased with the particle size. The flowability categories suggested by the three flowability indicators were passable only for the coarser dusts. For the finer dusts, the flowability was overestimated by all flowability indicators.
Liu, Ho-Ling; Chang, Ting-Ting; Yan, Feng-Xian; Li, Cheng-He; Lin, Yu-Shi; Wong, Alex M
2015-06-01
The forward volumetric transfer constant (K(trans)), a physiological parameter extracted from dynamic contrast-enhanced (DCE) MRI, is weighted by vessel permeability and tissue blood flow. The permeability × surface area product per unit mass of tissue (PS) in brain tumors was estimated in this study by combining the blood flow obtained through pseudo-continuous arterial spin labeling (PCASL) and K(trans) obtained through DCE MRI. An analytical analysis and a numerical simulation were conducted to understand how errors in the flow and K(trans) estimates would propagate to the resulting PS. Fourteen pediatric patients with brain tumors were scanned on a clinical 3-T MRI scanner. PCASL perfusion imaging was performed using a three-dimensional (3D) fast-spin-echo readout module to determine blood flow. DCE imaging was performed using a 3D spoiled gradient-echo sequence, and the K(trans) map was obtained with the extended Tofts model. The numerical analysis demonstrated that the uncertainty of PS was predominantly dependent on that of K(trans) and was relatively insensitive to the flow. The average PS values of the whole tumors ranged from 0.006 to 0.217 min(-1), with a mean of 0.050 min(-1) among the patients. The mean K(trans) value was 18% lower than the PS value, with a maximum discrepancy of 25%. When the parametric maps were compared on a voxel-by-voxel basis, the discrepancies between PS and K(trans) appeared to be heterogeneous within the tumors. The PS values could be more than two-fold higher than the K(trans) values for voxels with high K(trans) levels. This study proposes a method that is easy to implement in clinical practice and has the potential to improve the quantification of the microvascular properties of brain tumors. Copyright © 2015 John Wiley & Sons, Ltd.
Zheng, Jun; Yu, Zhiyuan; Xu, Zhao; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-05-12
BACKGROUND Hematoma expansion is associated with poor outcome in intracerebral hemorrhage (ICH) patients. The spot sign and the blend sign are reliable tools for predicting hematoma expansion in ICH patients. The aim of this study was to compare the accuracy of the two signs in the prediction of hematoma expansion. MATERIAL AND METHODS Patients with spontaneous ICH were screened for the presence of the computed tomography angiography (CTA) spot sign and the non-contrast CT (NCCT) blend sign within 6 hours after onset of symptoms. The sensitivity, specificity, and positive and negative predictive values of the spot sign and the blend sign in predicting hematoma expansion were calculated. The accuracy of the spot sign and the blend sign in predicting hematoma expansion was analyzed by receiver-operator analysis. RESULTS A total of 115 patients were enrolled in this study. The spot sign was observed in 25 (21.74%) patients, whereas the blend sign was observed in 22 (19.13%) patients. Of the 28 patients with hematoma expansion, the CTA spot sign was found on admission CT scans in 16 (57.14%) and the NCCT blend sign in 12 (42.86%), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the spot sign for predicting hematoma expansion were 57.14%, 89.66%, 64.00%, and 86.67%, respectively. In contrast, the sensitivity, specificity, positive predictive value, and negative predictive value of the blend sign were 42.86%, 88.51%, 54.55%, and 82.80%, respectively. The area under the curve (AUC) of the spot sign was 0.734, which was higher than that of the blend sign (0.657). CONCLUSIONS Both the spot sign and the blend sign seemed to be good predictors for hematoma expansion, and the spot sign appeared to have better predictive accuracy.
Zheng, Jun; Yu, Zhiyuan; Xu, Zhao; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-01-01
Background Hematoma expansion is associated with poor outcome in intracerebral hemorrhage (ICH) patients. The spot sign and the blend sign are reliable tools for predicting hematoma expansion in ICH patients. The aim of this study was to compare the accuracy of the two signs in the prediction of hematoma expansion. Material/Methods Patients with spontaneous ICH were screened for the presence of the computed tomography angiography (CTA) spot sign and the non-contrast CT (NCCT) blend sign within 6 hours after onset of symptoms. The sensitivity, specificity, and positive and negative predictive values of the spot sign and the blend sign in predicting hematoma expansion were calculated. The accuracy of the spot sign and the blend sign in predicting hematoma expansion was analyzed by receiver-operator analysis. Results A total of 115 patients were enrolled in this study. The spot sign was observed in 25 (21.74%) patients, whereas the blend sign was observed in 22 (19.13%) patients. Of the 28 patients with hematoma expansion, the CTA spot sign was found on admission CT scans in 16 (57.14%) and the NCCT blend sign in 12 (42.86%), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the spot sign for predicting hematoma expansion were 57.14%, 89.66%, 64.00%, and 86.67%, respectively. In contrast, the sensitivity, specificity, positive predictive value, and negative predictive value of the blend sign were 42.86%, 88.51%, 54.55%, and 82.80%, respectively. The area under the curve (AUC) of the spot sign was 0.734, which was higher than that of the blend sign (0.657). Conclusions Both the spot sign and the blend sign seemed to be good predictors for hematoma expansion, and the spot sign appeared to have better predictive accuracy. PMID:28498827
NASA Technical Reports Server (NTRS)
Nicely, Julie M.; Anderson, Daniel C.; Canty, Timothy P.; Salawitch, Ross J.; Wolfe, Glenn M.; Apel, Eric C.; Arnold, Steve R.; Atlas, Elliot L.; Blake, Nicola J.; Bresch, James F.;
2016-01-01
Hydroxyl radical (OH) is the main daytime oxidant in the troposphere and determines the atmospheric lifetimes of many compounds. We use aircraft measurements of O3, H2O, NO, and other species from the Convective Transport of Active Species in the Tropics (CONTRAST) field campaign, which occurred in the tropical western Pacific (TWP) during January-February 2014, to constrain a photochemical box model and estimate concentrations of OH throughout the troposphere. We find that tropospheric column OH (OHCOL) inferred from CONTRAST observations is 12 to 40% higher than found in chemical transport models (CTMs), including CAM-chem-SD run with 2014 meteorology as well as eight models that participated in POLMIP (2008 meteorology). Part of this discrepancy is due to a clear-sky sampling bias that affects CONTRAST observations; accounting for this bias and also for a small difference in chemical mechanism results in our empirically based value of OHCOL being 0 to 20% larger than found within global models. While these global models simulate observed O3 reasonably well, they underestimate NOx (NO +NO2) by a factor of 2, resulting in OHCOL approx.30% lower than box model simulations constrained by observed NO. Underestimations by CTMs of observed CH3CHO throughout the troposphere and of HCHO in the upper troposphere further contribute to differences between our constrained estimates of OH and those calculated by CTMs. Finally, our calculations do not support the prior suggestion of the existence of a tropospheric OH minimum in the TWP, because during January-February 2014 observed levels of O3 and NO were considerably larger than previously reported values in the TWP.
Nikolaou, Konstantin; Sommer, Wieland H.; Schmitt, Peter; Kazmierczak, Philipp M.; Reiser, Maximilian F.; Theisen, Daniel
2014-01-01
Purpose The aim of this study was to assess the diagnostic performance of ECG-gated non-contrast-enhanced quiescent interval single-shot (QISS) magnetic resonance angiography at a magnetic field strength of 3 Tesla in patients with advanced peripheral arterial occlusive disease (PAOD). Method and Materials A total of 21 consecutive patients with advanced PAOD (Fontaine stage IIb and higher) referred for peripheral magnetic resonance angiography (MRA) were included. Imaging was performed on a 3 T whole body MR. Image quality and stenosis diameter were evaluated in comparison to contrast-enhanced continuous table and TWIST MRA (CE-MRA) as standard of reference. QISS images were acquired with a thickness of 1.5 mm each (high-resolution QISS, HR-QISS). Two blinded readers rated the image quality and the degree of stenosis for both HR-QISS and CE-MRA in 26 predefined arterial vessel segments on 5-point Likert scales. Results With CE-MRA as the reference standard, HR-QISS showed high sensitivity (94.1%), specificity (97.8%), positive (95.1%), and negative predictive value (97.2%) for the detection of significant (≥50%) stenosis. Interreader agreement for stenosis assessment of both HR-QISS and CE-MRA was excellent (κ-values of 0.951 and 0.962, respectively). As compared to CR-MRA, image quality of HR-QISS was significantly lower for the distal aorta, the femoral and iliac arteries (each with p<0.01), while no significant difference was found in the popliteal (p = 0.09) and lower leg arteries (p = 0.78). Conclusion Non-enhanced ECG-gated HR-QISS performs very well in subjects with severe PAOD and is a good alternative for patients with a high risk of nephrogenic systemic fibrosis. PMID:24608937
Stenner, Philip; Schmidt, Bernhard; Allmendinger, Thomas; Flohr, Thomas; Kachelrie, Marc
2010-06-01
In cardiac perfusion examinations with computed tomography (CT) large concentrations of iodine in the ventricle and in the descending aorta cause beam hardening artifacts that can lead to incorrect perfusion parameters. The aim of this study is to reduce these artifacts by performing an iterative correction and by accounting for the 3 materials soft tissue, bone, and iodine. Beam hardening corrections are either implemented as simple precorrections which cannot account for higher order beam hardening effects, or as iterative approaches that are based on segmenting the original image into material distribution images. Conventional segmentation algorithms fail to clearly distinguish between iodine and bone. Our new algorithm, DIBHC, calculates the time-dependent iodine distribution by analyzing the voxel changes of a cardiac perfusion examination (typically N approximately 15 electrocardiogram-correlated scans distributed over a total scan time up to T approximately 30 s). These voxel dynamics are due to changes in contrast agent. This prior information allows to precisely distinguish between bone and iodine and is key to DIBHC where each iteration consists of a multimaterial (soft tissue, bone, iodine) polychromatic forward projection, a raw data comparison and a filtered backprojection. Simulations with a semi-anthropomorphic dynamic phantom and clinical scans using a dual source CT scanner with 2 x 128 slices, a tube voltage of 100 kV, a tube current of 180 mAs, and a rotation time of 0.28 seconds have been carried out. The uncorrected images suffer from beam hardening artifacts that appear as dark bands connecting large concentrations of iodine in the ventricle, aorta, and bony structures. The CT-values of the affected tissue are usually underestimated by roughly 20 HU although deviations of up to 61 HU have been observed. For a quantitative evaluation circular regions of interest have been analyzed. After application of DIBHC the mean values obtained deviate by only 1 HU for the simulations and the corrected values show an increase of up to 61 HU for the measurements. One iteration of DIBHC greatly reduces the beam hardening artifacts induced by the contrast agent dynamics (and those due to bone) now allowing for an improved assessment of contrast agent uptake in the myocardium which is essential for determining myocardial perfusion.
Leiter, Michael P; Jackson, Nicole J; Shaughnessy, Krystelle
2009-01-01
This paper examines the contrasting role of work values for nurses from two generations: Baby Boomers and Generation X. Differences among nurses regarding core values pertaining to their work has a potential to influence the quality of their work life. These differences may have implications for their vulnerability to job burnout. The analysis is based upon questionnaire surveys of nurses representing Generation X (n = 255) and Baby Boomers (n = 193) that contrasted their responses on job burnout, areas of work life, knowledge transfer and intention to quit. The analysis identified a greater person/organization value mismatch for Generation X nurses than for Baby Boomer nurses. Their greater value mismatch was associated with a greater susceptibility to burnout and a stronger intention to quit for Generation X nurses. The article notes the influence of Baby Boomer nurses in the structure of work and the application of new knowledge in health care work settings. Implications for recruitment and retention are discussed with a focus on knowledge transfer activities associated with distinct learning styles. Understanding value differences between generations will help nursing managers to develop more responsive work settings for nurses of all ages.
NASA Astrophysics Data System (ADS)
Lamarche, Leslie J.; Makarevich, Roman A.
2017-03-01
We present observations of plasma density gradients, electric fields, and small-scale plasma irregularities near a polar cap patch made by the Super Dual Auroral Radar Network radar at Rankin Inlet (RKN) and the northern face of Resolute Bay Incoherent Scatter Radar (RISR-N). RKN echo power and occurrence are analyzed in the context of gradient-drift instability (GDI) theory, with a particular focus on the previously uninvestigated 2-D dependencies on wave propagation, electric field, and gradient vectors, with the latter two quantities evaluated directly from RISR-N measurements. It is shown that higher gradient and electric field components along the wave vector generally lead to the higher observed echo occurrence, which is consistent with the expected higher GDI growth rate, but the relationship with echo power is far less straightforward. The RKN echo power increases monotonically as the predicted linear growth rate approaches zero from negative values but does not continue this trend into positive growth rate values, in contrast with GDI predictions. The observed greater consistency of echo occurrence with GDI predictions suggests that GDI operating in the linear regime can control basic plasma structuring, but measured echo strength may be affected by other processes and factors, such as multistep or nonlinear processes or a shear-driven instability.
Microclimate Evaluation of the Hradec Králové City using HUMIDEX
NASA Astrophysics Data System (ADS)
Rožnovský, Jaroslav; Litschmann, Tomáš; Středová, Hana; Středa, Tomáš; Salaš, Petr; Horká, Marie
2017-09-01
Urban environment differs from the surrounding landscape in terms of the values of meteorological parameters. This is often referred to as the urban heat island (UHI), which in simple terms means higher air temperatures in cities. The cause of these changes lies in the different active surfaces in cities, which subsequently results in a different radiation balance. The higher temperatures, however, also affect the living conditions in the city and during very high temperature periods can have negative effects on the health of the city inhabitants. The results presented in this paper are based on measurements taken over several years at locations near Hradec Králové, which is surrounded by different surface areas. Environment analysis was performed using the Humidex index. The obtained results show that replacing green areas with built-up areas affects temperatures in the city, when air temperatures are very high they significantly increase the discomfort of the inhabitants. Differences in the frequency of discomfort levels are observed especially during periods of high temperatures, at lower temperatures these differences are not significant. Higher frequencies of discomfort are observed at locations with artificial surfaces (asphalt, cobblestones, concrete) and in closed spaces. In contrast, locations with lots of green areas almost always have the value of this index lower or more balanced. The results should therefore be a valid argument for maintaining and extending green areas in cities.
Prior experiences of racial discrimination and racial differences in health care system distrust.
Armstrong, Katrina; Putt, Mary; Halbert, Chanita H; Grande, David; Schwartz, Jerome Sanford; Liao, Kaijun; Marcus, Noora; Demeter, Mirar B; Shea, Judy A
2013-02-01
Factors contributing to racial differences in health care system distrust (HCSD) are currently unknown. Proposed potential contributing factors are prior experiences of racial discrimination and racial residential segregation. Random digit dialing survey of 762 African American and 1267 white adults living in 40 US metropolitan statistical areas. Measures included the Revised Health Care System Distrust scale, the Experiences of Discrimination scale, metrics of access to care, sociodemographic characteristics, and the level of racial residential segregation in the city (using the isolation index). In unadjusted analyses, African Americans had higher levels of HCSD, particularly values distrust, and greater experiences of discrimination. Experience of discrimination was also strongly associated with HCSD. Adjusting for sociodemographic characteristics, health care access, and residential segregation had little effect on the association between African American race and overall HCSD or values distrust. In contrast, adjusting for experiences of racial discrimination reversed the association so that distrust was lower among African Americans than whites (odds ratio 0.53; 95% confidence interval, 0.33-0.85 for the overall measure). The Sobel test for mediation was strongly significant (P<0.001). Higher HCSD among African Americans is explained by a greater burden of experiences of racial discrimination than whites. Reasons for higher distrust among whites after adjusting for experiences of racial discrimination are not known. Efforts to eliminate racial discrimination and restore trust given prior discrimination are needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Subashi, Ergys; Choudhury, Kingshuk R.; Johnson, G. Allan, E-mail: gjohnson@duke.edu
2014-03-15
Purpose: The pharmacokinetic parameters derived from dynamic contrast-enhanced (DCE) MRI have been used in more than 100 phase I trials and investigator led studies. A comparison of the absolute values of these quantities requires an estimation of their respective probability distribution function (PDF). The statistical variation of the DCE-MRI measurement is analyzed by considering the fundamental sources of error in the MR signal intensity acquired with the spoiled gradient-echo (SPGR) pulse sequence. Methods: The variance in the SPGR signal intensity arises from quadrature detection and excitation flip angle inconsistency. The noise power was measured in 11 phantoms of contrast agentmore » concentration in the range [0–1] mM (in steps of 0.1 mM) and in onein vivo acquisition of a tumor-bearing mouse. The distribution of the flip angle was determined in a uniform 10 mM CuSO{sub 4} phantom using the spin echo double angle method. The PDF of a wide range of T1 values measured with the varying flip angle (VFA) technique was estimated through numerical simulations of the SPGR equation. The resultant uncertainty in contrast agent concentration was incorporated in the most common model of tracer exchange kinetics and the PDF of the derived pharmacokinetic parameters was studied numerically. Results: The VFA method is an unbiased technique for measuringT1 only in the absence of bias in excitation flip angle. The time-dependent concentration of the contrast agent measured in vivo is within the theoretically predicted uncertainty. The uncertainty in measuring K{sup trans} with SPGR pulse sequences is of the same order, but always higher than, the uncertainty in measuring the pre-injection longitudinal relaxation time (T1{sub 0}). The lowest achievable bias/uncertainty in estimating this parameter is approximately 20%–70% higher than the bias/uncertainty in the measurement of the pre-injection T1 map. The fractional volume parameters derived from the extended Tofts model were found to be extremely sensitive to the variance in signal intensity. The SNR of the pre-injection T1 map indicates the limiting precision with which K{sup trans} can be calculated. Conclusions: Current small-animal imaging systems and pulse sequences robust to motion artifacts have the capacity for reproducible quantitative acquisitions with DCE-MRI. In these circumstances, it is feasible to achieve a level of precision limited only by physiologic variability.« less
Viswanathan, Sivaram; Jayakumar, Jaikishan; Vidyasagar, Trichur R
2015-09-01
Responses of most neurons in the primary visual cortex of mammals are markedly selective for stimulus orientation and their orientation tuning does not vary with changes in stimulus contrast. The basis of such contrast invariance of orientation tuning has been shown to be the higher variability in the response for low-contrast stimuli. Neurons in the lateral geniculate nucleus (LGN), which provides the major visual input to the cortex, have also been shown to have higher variability in their response to low-contrast stimuli. Parallel studies have also long established mild degrees of orientation selectivity in LGN and retinal cells. In our study, we show that contrast invariance of orientation tuning is already present in the LGN. In addition, we show that the variability of spike responses of LGN neurons increases at lower stimulus contrasts, especially for non-preferred orientations. We suggest that such contrast- and orientation-sensitive variability not only explains the contrast invariance observed in the LGN but can also underlie the contrast-invariant orientation tuning seen at the level of the primary visual cortex. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Fani, Parisa; Patlas, Michael N; Monteiro, Sandra; Katz, Douglas S
2018-02-02
To determine the yield of non-contrast multi-detector computed tomography (MDCT) of the abdomen and pelvis in diagnosing ureteral calculi as well as other alternative acute conditions in male vs in female adult patients presenting to the emergency department with new onset of symptoms. Our institutional review board approved a retrospective review of the official reports of the non-contrast MDCT examinations of the abdomen and pelvis performed on adults (18 years and older) presenting to our emergency department with a suspected ureteral calculus from October 1, 2011 to October 30, 2013. Patients with recently documented ureteral calculi, known urinary tract infection, malignancy, and trauma were excluded from the study. From a total of 1097 non-contrast MDCT examinations of the abdomen and pelvis over the 2-year period, 400 randomly selected examinations were reviewed (approximately one-third of all the examinations). We compared the prevalence of ureteral calculi between the male and female population. P values and confidence intervals were determined using software Stata 14. Other acute intra-abdominal and intra-pelvic findings amenable to prompt medical care were also documented and analyzed separately. The mean patient age was 55.2 years, with a range of 19-90 years. This included 170 female (mean age 56.8 years) and 230 male patients (mean age 54.2 years). Ureteral calculi were detected in 170 (42.5%) of the patients [111 males (48%) and 59 females (34.7%)] with a prevalence which was statistically significantly higher in the male patients compared to in the female patients (P < 0.01, confidence level of 95% and CI of 13.2-13.4). An alternative diagnosis was made based on the MDCT findings in 49 patient cases (12.25 %), including 26 females (15.29%) and 23 males (10.00%). There was no statistically significant difference in alternative acute findings in male compared to in female patients (P > 0.05). This was with the exception of acute pyelonephritis, which was statistically significantly higher in the female patients (P < 0.01). The likelihood of making the diagnosis of a ureteral calculus on non-contrast MDCT of the abdomen and pelvis was statistically significantly higher in male patients compared with female patients presenting to our emergency department. However, there was no statistically significant difference in the alternative diagnoses, with the exception of pyelonephritis, which was more common in women. Copyright © 2018 Elsevier Inc. All rights reserved.
Thermal x-ray diffraction and near-field phase contrast imaging
NASA Astrophysics Data System (ADS)
Li, Zheng; Classen, Anton; Peng, Tao; Medvedev, Nikita; Wang, Fenglin; Chapman, Henry N.; Shih, Yanhua
2017-10-01
Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase contrast imaging (PCI), in order to achieve superresolution in x-ray diffraction and obtain enhanced intensity contrast in PCI. The cost of implementing such schemes is minimal compared to the methods that achieve similar effects by using entangled x-ray photon pairs.
Thermal x-ray diffraction and near-field phase contrast imaging
Li, Zheng; Classen, Anton; Peng, Tao; ...
2017-12-27
Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. Here in this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase contrast imaging (PCI), in order to achieve superresolution in x-ray diffraction and obtain enhanced intensity contrast in PCI. The cost of implementing such schemes is minimal compared to the methods that achieve similar effects by using entangled x-ray photon pairs.
Novel high contrast electrochromic polymer materials based on 3,4-propylenedioxythiophene
NASA Astrophysics Data System (ADS)
Sahoo, Rabindra; Mishra, Sarada P.; Kumar, Anil; Sindhu, S.; Narasimha Rao, K.; Gopal, E. S. R.
2007-09-01
Mono and di allyl and napthyl substituted 3,4-propylenedioxythiophenes were synthesized and polymerized electrochemically. All the monomers were characterized for their molecular structures, and the polymers were characterized for their electrochemical properties. The disubstituted derivatives showed higher contrast than the corresponding mono substituted derivatives. The allyl substituted polymers showed higher contrast and faster switching time than corresponding napthyl substituted derivatives. The presence of the allyl group as the pendant can be used for further functionalization of the polymer.
Li, Xiaojuan; Pai, Alex; Blumenkrantz, Gabrielle; Carballido-Gamio, Julio; Link, Thomas; Ma, Benjamin; Ries, Michael; Majumdar, Sharmila
2009-01-01
T1ρ and T2 relaxation time constants have been proposed to probe biochemical changes in osteoarthritic cartilage. This study aimed to evaluate the spatial correlation and distribution of T1ρ and T2 values in osteoarthritic cartilage. Ten patients with osteoarthritis (OA) and 10 controls were studied at 3T. The spatial correlation of T1ρ and T2 values was investigated using Z-scores. The spatial variation of T1ρ and T2 values in patellar cartilage was studied in different cartilage layers. The distribution of these relaxation time constants was measured using texture analysis parameters based on gray-level co-occurrence matrices (GLCM). The mean Z-scores for T1ρ and T2 values were significantly higher in OA patients vs. controls (P < 0.05). Regional correlation coefficients of T1ρ and T2 Z-scores showed a large range in both controls and OA patients (0.2– 0.7). OA patients had significantly greater GLCM contrast and entropy of T1ρ values than controls (P < 0.05). In summary, T1ρ and T2 values are not only increased but are also more heterogeneous in osteoarthritic cartilage. T1ρ and T2 values show different spatial distributions and may provide complementary information regarding cartilage degeneration in OA. PMID:19319904
Infant sleeping arrangements and cultural values among contemporary Japanese mothers
Shimizu, Mina; Park, Heejung; Greenfield, Patricia M.
2014-01-01
We examined infant sleeping arrangements and cultural values of Japanese mothers in 2008 and 2009. Based on Greenfield's theory of social change and human development, we predicted that social change in Japan over the last decades (higher economic and education level, urbanization, complex technology, more women in the work force) would lead to a decline in mother-infant co-sleeping, compared with published findings concerning Japanese sleeping arrangements in the 1960s and 1980s. We also predicted that the practice of having babies sleep in their own beds and/or own rooms would be supported by ethnotheories stressing infant independence and other values adaptive in an urban, technologically sophisticated, relatively wealthy, and highly educated populace. Fifty-one Japanese mothers' comments posted on Internet parenting forums were analyzed. Contrary to our hypothesis, co-sleeping was as frequent among Japanese mothers in 2008-2009 as it had been in the 1960s and 1980s. However, analysis of the values of co-sleeping mothers revealed frequent discrepancies between values and practices. In contrast, the minority of mothers whose babies slept alone in a separate room all expressed consonant values. Our qualitative analysis indicates that it is not always easy for Japanese mothers to construct values for child rearing and gender roles that integrate traditional infant care practices with current sociodemographic conditions. PMID:25191281
The Effect of Ocular Surface Regularity on Contrast Sensitivity and Straylight in Dry Eye.
Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Asonuma, Sanae; Ogawa, Mai; Hiraoka, Takahiro; Oshika, Tetsuro; Nishida, Kohji
2017-05-01
To investigate the association between visual function and ocular surface regularity in dry eye. We enrolled 52 eyes of 52 dry eye patients (34 dry eyes with superficial punctate keratopathy [SPK] in the central corneal region [central SPK] and 18 dry eyes without central SPK) and 20 eyes of 20 normal control subjects. All eyes had a best-corrected distance visual acuity better than 20/20. We measured two indices of contrast sensitivity function under photopic conditions: contrast sensitivity and letter contrast sensitivity. The area under the log contrast sensitivity function (AULCSF) was calculated from the obtained contrast sensitivity data. Straylight was quantified using a straylight meter. Dry eyes with central SPK had significantly decreased contrast sensitivity function, including AULCSF and letter contrast sensitivity than those without central SPK and normal eyes (P < 0.05 for each). While the straylight values in both dry eye groups did not differ, straylight values were greater than those in normal eyes (P < 0.05 for both). In dry eye, the AULCSF and letter contrast sensitivity negatively correlated with the central SPK score (R = -0.485, P < 0.001, and R = -0.541, P < 0.001, respectively). In dry eye, reduced contrast sensitivity in part results from central SPK overlying the optical zone and the increased straylight results from tear film instability rather than central SPK.
Lakhal, Karim; Ehrmann, Stephan; Chaari, Anis; Laissy, Jean-Pierre; Régnier, Bernard; Wolff, Michel; Pajot, Olivier
2011-12-01
Contrast-induced nephropathy (CIN) has been extensively studied in the ward but only scarcely in intensive care unit (ICU) patients, even if they may be particularly prone to develop or to worsen acute kidney insufficiency. We aimed to measure the incidence of CIN in a large ICU population using the Acute Kidney Injury Network (AKIN) definition and to investigate its impact on patients' outcome. In this 3-year retrospective study, we included all patients undergoing, during their stay in our medical ICU, a contrast media-enhanced computed tomographic scan. Change in serum creatinine between baseline (24 hours before to 12 hours after contrast media injection) and its maximum value over the 96 hours after contrast media injection was recorded. Contrast-induced nephropathy was defined as a 44.2-μmol/L absolute or a 25% relative minimal increase in serum creatinine over 48, 72, or 96 hours and according to the stage 1 of the AKIN classification (at least 26.4 μmol/L or 50% increase over 48 hours). A total of 398 contrast-enhanced computed tomographic scans performed among 299 patients were analyzed. Incidence of CIN was 14% according to the AKIN definition and ranged from 8% (48-hour absolute definition) to 23% (96-hour relative definition). The need for renal replacement therapy and ICU mortality were significantly higher in case of CIN. After adjusting for other variables associated with ICU mortality, the occurrence of at least 1 CIN episode during the ICU stay (AKIN criteria) was independently associated with ICU mortality (odds ratio, 3.85; 95% confidence interval, 1.85-8.00). Even if incidence varied greatly depending on the definition, CIN appeared frequent in our critically ill patients. The AKIN definition, independently associated with ICU mortality, may allow unifying diagnostic criteria to further evaluate this condition that impacts morbidity and mortality. Copyright © 2011 Elsevier Inc. All rights reserved.
Towards endometriosis diagnosis by gadofosveset-trisodium enhanced magnetic resonance imaging.
Schreinemacher, Marc H; Backes, Walter H; Slenter, Jos M; Xanthoulea, Sofia; Delvoux, Bert; van Winden, Larissa; Beets-Tan, Regina G; Evers, Johannes L H; Dunselman, Gerard A J; Romano, Andrea
2012-01-01
Endometriosis is defined as the presence of endometrial tissue outside the uterus. It affects 10-15% of women during reproductive age and has a big personal and social impact due to chronic pelvic pain, subfertility, loss of work-hours and medical costs. Such conditions are exacerbated by the fact that the correct diagnosis is made as late as 8-11 years after symptom presentation. This is due to the lack of a reliable non-invasive diagnostic test and the fact that the reference diagnostic standard is laparoscopy (invasive, expensive and not without risks). High-molecular weight gadofosveset-trisodium is used as contrast agent in Magnetic Resonance Imaging (MRI). Since it extravasates from hyperpermeable vessels more easily than from mature blood vessels, this contrast agent detects angiogenesis efficiently. Endometriosis has high angiogenic activity. Therefore, we have tested the possibility to detect endometriosis non-invasively using Dynamic Contrast-Enhanced MRI (DCE-MRI) and gadofosveset-trisodium as a contrast agent in a mouse model. Endometriotic lesions were surgically induced in nine mice by autologous transplantation. Three weeks after lesion induction, mice were scanned by DCE-MRI. Dynamic image analysis showed that the rates of uptake (inwash), persistence and outwash of the contrast agent were different between endometriosis and control tissues (large blood vessels and back muscle). Due to the extensive angiogenesis in induced lesions, the contrast agent persisted longer in endometriotic than control tissues, thus enhancing the MRI signal intensity. DCE-MRI was repeated five weeks after lesion induction, and contrast enhancement was similar to that observed three weeks after endometriosis induction. The endothelial-cell marker CD31 and the pericyte marker α-smooth-muscle-actin (mature vessels) were detected with immunohistochemistry and confirmed that endometriotic lesions had significantly higher prevalence of new vessels (CD31 only positive) than the uterus and control tissues. The diagnostic value of gadofosveset-trisodium to detect endometriosis should be tested in human settings.
Zhao, Sibo; Zhang, Jie
2018-06-19
This study examined the differences of psychological strains between Chinese and American college students and discussed how strains may influence individuals' suicidal ideation and depression. A total of 539 college students (298 from China and 241 from the U.S.) were recruited in March 2016 to complete the survey study. Multiple linear regressions were used in data analysis. Students in America had higher scores on depression and stress than students in China, while students in China rated higher on suicidal ideation than students in America. In contrast of students in America facing more coping strains, students in China were confronting more value strains in their life. The cross-cultural variations in the effect of psychological strains have been substantiated in current study, indicating that understanding the psychological strains in different cultural contexts is necessary for the early intervention and prevention in college aged populations.
Thunderstorms and ground-based radio noise as observed by radio astronomy Explorer 1
NASA Technical Reports Server (NTRS)
Caruso, J. A.; Herman, J. R.
1973-01-01
Radio Astronomy Explorer (RAE) data were analyzed to determine the frequency dependence of HF terrestrial radio noise power. RAE observations of individual thunderstorms, mid-ocean areas, and specific geographic regions for which concommitant ground based measurements are available indicate that noise power is a monotonically decreasing function of frequency which conforms to expectations over the geographic locations and time periods investigated. In all cases investigated, active thunderstorm regions emit slightly higher power as contrasted to RAE observations of the region during meteorologically quiet periods. Noise levels are some 15 db higher than predicted values over mid-ocean, while in locations where ground based measurements are available a maximum deviation of 5 db occurs. Worldwide contour mapping of the noise power at 6000 km for five individual months and four observing frequencies, examples of which are given, indicate high noise levels over continental land masses with corresponding lower levels over ocean regions.
Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael
2017-12-01
The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.
Investigation of X-ray permeability of surgical gloves coated with different contrast agents
Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel
2016-01-01
Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548
The 3D model: explaining densification and deformation mechanisms by using 3D parameter plots.
Picker, Katharina M
2004-04-01
The aim of the study was to analyze very differently deforming materials using 3D parameter plots and consequently to gain deeper insights into the densification and deformation process described with the 3D model in order to define an ideal tableting excipient. The excipients used were dicalcium phosphate dihydrate (DCPD), sodium chloride (NaCl), microcrystalline cellulose (MCC), xylitol, mannitol, alpha-lactose monohydrate, maltose, hydroxypropyl methylcellulose (HPMC), sodium carboxymethylcellulose (NaCMC), cellulose acetate (CAC), maize starch, potato starch, pregelatinized starch, and maltodextrine. All of the materials were tableted to graded maximum relative densities (rhorel, max) using an eccentric tableting machine. The data which resulted, namely force, displacement, and time, were analyzed by the application of 3D modeling. Different particle size fractions of DCPD, CAC, and MCC were analyzed in addition. Brittle deforming materials such as DCPD exhibited a completely different 3D parameter plot, with low time plasticity, d, and low pressure plasticity, e, and a strong decrease in omega values when densification increased, in contrast to the plastically deforming MCC, which had much higher d, e, and omega values. e and omega values changed only slightly when densification increased for MCC. NaCl showed less of a decrease in omega values than DCPD did, and the d and e values were between those of MCC and DCPD. The sugar alcohols, xylitol and mannitol, behaved in a similar fashion to sodium chloride. This is also valid for the crystalline sugars, alpha-lactose monohydrate, and maltose. However, the sugars are more brittle than the sugar alcohols. The cellulose derivatives, HPMC, NaCMC, and CAC, are as plastic as MCC, however, their elasticity depends on substitution indicated by lower (more elastic) or higher (less elastic) omega values. The native starches, maize starch and potato starch, are very elastic, and pregelatinized starch and maltodextrine are less elastic and exhibited higher omega values. Deformation behavior as shown in 3D parameter plots depends on particle size for polymers such as CAC and MCC; however, it does not depend on particle size for brittle materials such as DCPD. An ideally deforming tableting excipient should exhibit high e, d, and omega values with a constant ratio of e and omega at increasing densification.
Near-IR and CP-OCT Imaging of Suspected Occlusal Caries Lesions
Simon, Jacob C.; Kang, Hobin; Staninec, Michal; Jang, Andrew T.; Chan, Kenneth H.; Darling, Cynthia L.; Lee, Robert C.; Fried, Daniel
2017-01-01
Introduction Radiographic methods have poor sensitivity for occlusal lesions and by the time the lesions are radiolucent they have typically progressed deep into the dentin. New more sensitive imaging methods are needed to detect occlusal lesions. In this study, cross-polarization optical coherence tomography (CP-OCT) and near-IR imaging were used to image questionable occlusal lesions (QOC's) that were not visible on radiographs but had been scheduled for restoration on 30 test subjects. Methods Near-IR reflectance and transillumination probes incorporating a high definition InGaAs camera and near-IR broadband light sources were used to acquire images of the lesions before restoration. The reflectance probe utilized cross-polarization and operated at wavelengths from 1500–1700-nm where there is an increase in water absorption for higher contrast. The transillumination probe was operated at 1300-nm where the transparency of enamel is highest. Tomographic images (6×6×7 mm3) of the lesions were acquired using a high-speed swept-source CP-OCT system operating at 1300-nm before and after removal of the suspected lesion. Results Near-IR reflectance imaging at 1500–1700-nm yielded significantly higher contrast (p<0.05) of the demineralization in the occlusal grooves compared with visible reflectance imaging. Stains in the occlusal grooves greatly reduced the lesion contrast in the visible range yielding negative values. Only half of the 26 lesions analyzed showed the characteristic surface demineralization and increased reflectivity below the dentinal-enamel junction (DEJ) in 3D OCT images indicative of penetration of the lesion into the dentin. Conclusion This study demonstrates that near-IR imaging methods have great potential for improving the early diagnosis of occlusal lesions. PMID:28339115
Four Theorems on the Psychometric Function
May, Keith A.; Solomon, Joshua A.
2013-01-01
In a 2-alternative forced-choice (2AFC) discrimination task, observers choose which of two stimuli has the higher value. The psychometric function for this task gives the probability of a correct response for a given stimulus difference, . This paper proves four theorems about the psychometric function. Assuming the observer applies a transducer and adds noise, Theorem 1 derives a convenient general expression for the psychometric function. Discrimination data are often fitted with a Weibull function. Theorem 2 proves that the Weibull “slope” parameter, , can be approximated by , where is the of the Weibull function that fits best to the cumulative noise distribution, and depends on the transducer. We derive general expressions for and , from which we derive expressions for specific cases. One case that follows naturally from our general analysis is Pelli's finding that, when , . We also consider two limiting cases. Theorem 3 proves that, as sensitivity improves, 2AFC performance will usually approach that for a linear transducer, whatever the actual transducer; we show that this does not apply at signal levels where the transducer gradient is zero, which explains why it does not apply to contrast detection. Theorem 4 proves that, when the exponent of a power-function transducer approaches zero, 2AFC performance approaches that of a logarithmic transducer. We show that the power-function exponents of 0.4–0.5 fitted to suprathreshold contrast discrimination data are close enough to zero for the fitted psychometric function to be practically indistinguishable from that of a log transducer. Finally, Weibull reflects the shape of the noise distribution, and we used our results to assess the recent claim that internal noise has higher kurtosis than a Gaussian. Our analysis of for contrast discrimination suggests that, if internal noise is stimulus-independent, it has lower kurtosis than a Gaussian. PMID:24124456
Teh, V; Sim, K S; Wong, E K
2016-11-01
According to the statistic from World Health Organization (WHO), stroke is one of the major causes of death globally. Computed tomography (CT) scan is one of the main medical diagnosis system used for diagnosis of ischemic stroke. CT scan provides brain images in Digital Imaging and Communication in Medicine (DICOM) format. The presentation of CT brain images is mainly relied on the window setting (window center and window width), which converts an image from DICOM format into normal grayscale format. Nevertheless, the ordinary window parameter could not deliver a proper contrast on CT brain images for ischemic stroke detection. In this paper, a new proposed method namely gamma correction extreme-level eliminating with weighting distribution (GCELEWD) is implemented to improve the contrast on CT brain images. GCELEWD is capable of highlighting the hypodense region for diagnosis of ischemic stroke. The performance of this new proposed technique, GCELEWD, is compared with four of the existing contrast enhancement technique such as brightness preserving bi-histogram equalization (BBHE), dualistic sub-image histogram equalization (DSIHE), extreme-level eliminating histogram equalization (ELEHE), and adaptive gamma correction with weighting distribution (AGCWD). GCELEWD shows better visualization for ischemic stroke detection and higher values with image quality assessment (IQA) module. SCANNING 38:842-856, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Wang, Yan; Ji, Lei; Zhang, Bingbo; Yin, Peihao; Qiu, Yanyan; Song, Daqian; Zhou, Juying; Li, Qi
2013-05-01
Multi-modal imaging based on multifunctional nanoparticles is a promising alternative approach to improve the sensitivity of early cancer diagnosis. In this study, highly upconverting fluorescence and strong relaxivity rare-earth nanoparticles coated with paramagnetic lanthanide complex shells and polyethylene glycol (PEGylated UCNPs@DTPA-Gd3+) are synthesized as dual-modality imaging contrast agents (CAs) for upconverting fluorescent and magnetic resonance dual-modality imaging. PEGylated UCNPs@DTPA-Gd3+ with sizes in the range of 32-86 nm are colloidally stable. They exhibit higher longitudinal relaxivity and transverse relaxivity in water (r1 and r2 values are 7.4 and 27.8 s-1 per mM Gd3+, respectively) than does commercial Gd-DTPA (r1 and r2 values of 3.7 and 4.6 s-1 per mM Gd3+, respectively). They are found to be biocompatible. In vitro cancer cell imaging shows good imaging contrast of PEGylated UCNPs@DTPA-Gd3+. In vivo upconversion fluorescent imaging and T1-weighted MRI show excellent enhancement of both fluorescent and MR signals in the livers of mice administered PEGylated UCNPs@DTPA-Gd3+. All the experimental results indicate that the synthesized PEGylated UCNPs@DTPA-Gd3+ present great potential for biomedical upconversion of fluorescent and magnetic resonance dual-modality imaging applications.
Shimada, Kotaro; Isoda, Hiroyoshi; Hirokawa, Yuusuke; Arizono, Shigeki; Shibata, Toshiya; Togashi, Kaori
2010-11-01
To compare the accuracy of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI with that of diffusion-weighted MRI (DWI) in the detection of small hepatic metastases (2 cm or smaller). Forty-five patients underwent abdominal MRI at 3 T, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI (HASTE), DWI with a b-value of 500 s/mm(2) and contrast-enhanced MRI with Gd-EOB-DTPA. Two groups were assigned and compared: group A (T1WI, T2WI, HASTE and contrast-enhanced study with Gd-EOB-DTPA), and group B (T1WI, T2WI, HASTE and DWI). Two observers independently interpreted the images obtained in a random order. For all hepatic metastases, the diagnostic performance using each imaging set was evaluated by receiver-operating characteristic (ROC) curve analysis. A total of 51 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B, and the difference in the mean Az values between the two image sets was statistically significant, whereas, there were three metastases that lay near thin vessels or among multiple cysts and were better visualised in group B than in group A. Gd-EOB-DTPA-enhanced MRI showed higher accuracy in the detection of small metastases than DWI.
Shiozawa, Kazue; Watanabe, Manabu; Ikehara, Takashi; Matsukiyo, Yasushi; Kogame, Michio; Kikuchi, Yoshinori; Otsuka, Yuichiro; Kaneko, Hironori; Igarashi, Yoshinori; Sumino, Yasukiyo
2017-03-04
To compare contrast-enhanced ultrasonography (CEUS) using Sonazoid with Gd-EOB-DTPA-enhanced MRI (EOB-MRI) in the diagnosis of liver metastases in patients with colorectal cancer. A total of 69 patients diagnosed with or suspected of having liver metastasis were enrolled. These hepatic lesions were diagnosed by histopathological examination after surgical resection or based on follow-up using various imaging modalities. The diagnostic accuracies of CEUS and EOB-MRI were compared. One hundred thirty-three lesions were detected. Of these lesions, 109 were diagnosed as liver metastases. Of the 133 lesions, 90.2% were detected on CEUS, and 98.5% on EOB-MRI. One hundred nine lesions were diagnosed as liver metastasis. The areas under the receiver operating characteristic curve for diagnosis were 0.906 and 0.851 on CEUS and EOB-MRI, respectively (p = 0.41). Sensitivity, specificity, positive predictive value (PPV), negative predictive value, and overall accuracy were 90.8%, 84.5%, 97.1%, 67.1%, and 90.2%, respectively, for CEUS, and 95.4%, 70.8%, 93.7%, 77.3%, and 91%, respectively, for EOB-MRI. CEUS has a higher specificity and PPV for the diagnosis of liver metastasis than EOB-MRI. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:138-144, 2017. © 2016 The Authors Journal of Clinical Ultrasound Published by Wiley Periodicals, Inc.
Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images.
Vasconcelos, Taruska Ventorini; Bechara, Boulos B; McMahan, Clyde Alex; Freitas, Deborah Queiroz; Noujeim, Marcel
2017-02-01
To evaluate zirconium implant artifact production in cone beam computed tomography images obtained with different protocols. One zirconium implant was inserted in an edentulous mandible. Twenty scans were acquired with a ProMax 3D unit (Planmeca Oy, Helsinki, Finland), with acquisition settings ranging from 70 to 90 peak kilovoltage (kVp) and voxel sizes of 0.32 and 0.16 mm. A metal artifact reduction (MAR) tool was activated in half of the scans. An axial slice through the middle region of the implant was selected for each dataset. Gray values (mean ± standard deviation) were measured in two regions of interest, one close to and the other distant from the implant (control area). The contrast-to-noise ratio was also calculated. Standard deviation decreased with greater kVp and when the MAR tool was used. The contrast-to-noise ratio was significantly higher when the MAR tool was turned off, except for low resolution with kVp values above 80. Selection of the MAR tool and greater kVp resulted in an overall reduction of artifacts in images acquired with low resolution. Although zirconium implants do produce image artifacts in cone-bean computed tomography scans, the setting that best controlled artifact generation by zirconium implants was 90 kVp at low resolution and with the MAR tool turned on. Copyright © 2016 Elsevier Inc. All rights reserved.
Chan, Kenneth H; Fried, Daniel
2018-06-01
The enamel scattering coefficient decreases markedly with increasing wavelength from the visible to the near-infrared (NIR). However, beyond 1300 nm, the scattering coefficient is difficult to measure, and it is not known whether light scattering continues to decrease significantly at longer wavelengths. It is hypothesized that water absorption is a major contributor to the contrast between sound and demineralized enamel beyond 1300 nm since deeply penetrating photons in sound enamel are likely absorbed by water. Reflectance images of demineralization on tooth surfaces were acquired at wavelengths near 1450, 1860, 1880, and 1950 nm. The magnitude of water absorption is similar at 1450 and 1880 nm but varies markedly between 1860, 1880, and 1950 nm. Multispectral comparisons of lesion contrast provide insight into the mechanism responsible for higher contrast at longer NIR wavelengths. The highest contrast was at 1950 nm; however, the markedly higher contrast at 1880 compared to 1450 nm and similar contrast between 1860 and 1880 nm suggests that the enamel scattering coefficient continues to decrease beyond 1300 nm, and that reduced light scattering in sound enamel is most responsible for the higher lesion contrast at longer NIR wavelengths. This has important implications for the choice of wavelengths for caries detection and diagnostic devices, including the performance of optical coherence tomography beyond 1300 nm. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Atmospheric Pollution and Greenhouse Emissions over 14 Largest Megacities of the World
NASA Astrophysics Data System (ADS)
Chen, X.; Singh, R. P.
2017-12-01
Megacities have more than 10 million people, some of them are located in developing/developed countries. We have considered the top 14 megacities of the world. Due to growing industries, urbanization, vehicular density, and energy demand, greenhouse gas emissions have increased, which has degraded air quality. In some countries, clean air act has improved the air quality. We have considered multiple satellites and have retrieved atmospheric pollution parameters (aerosol optical depth-AOD and angstrom exponent) and greenhouse gases to study their variability from the period 2002-2016. High AOD represents high pollution level, which are prominent during winter and spring for Manila, Tokyo, Beijing, Moscow, Mexico City, Mumbai, Seoul, Dhaka, Cairo, and Bangkok. During summer and fall, Delhi, Karachi, and Sao Paulo have high values. During spring season, some of the megacities show significant higher pollution levels (high AOD) associated with the dust storms; however, Moscow and Karachi show contrasting behaviors. The angstrom exponent parameter has high values in the spring and summer for Manila, Shanghai, Beijing, Moscow, Sao Paulo, Mexico City, Seoul, and Cairo. Moscow shows a significant low value in April 2012. Delhi, Karachi, Mumbai, Dhaka, and Bangkok have high values in fall and winter. Dhaka shows significant low values in August 2003, June 2005, June 2008, July 2011, and June 2016. The total ozone column concentrations have high values during summer and spring, and low values during fall and winter. The methane concentrations are higher during fall and winter, and lower during spring and summer. An increasing trend of methane level is observed over all the megacities from 2002 until now. The increasing greenhouse gases in megacities have direct impact on human health and weather conditions. Some of the megacities suffer from dense haze, fog and smog, which impact the day-to-day lives of residents due to increasing concentrations of greenhouse gases.
Demopoulos, A.W.J.; Cormier, N.; Ewel, K.C.; Fry, B.
2008-01-01
The mangrove or mud crab, Scylla serrata, is an important component of mangrove fisheries throughout the Indo-Pacific. Understanding crab diets and habitat use should assist in managing these fisheries and could provide additional justification for conservation of the mangrove ecosystem itself. We used multiple chemical tracers to test whether crab movements were restricted to local mangrove forests, or extended to include adjacent seagrass beds and reef flats. We sampled three mangrove forests on the island of Kosrae in the Federated States of Micronesia at Lelu Harbor, Okat River, and Utwe tidal channel. Samples of S. serrata and likely food sources were analyzed for stable carbon (??13C), nitrogen (??15N), and sulfur (??34S) isotopes. Scylla serrata tissues also were analyzed for phosphorus (P), cations (K, Ca, Mg, Na), and trace elements (Mn, Fe, Cu, Zn, and B). Discriminant analysis indicated that at least 87% of the crabs remain in each site as distinct populations. Crab stable isotope values indicated potential differences in habitat use within estuaries. Values for ??13C and ??34S in crabs from Okat and Utwe were low and similar to values expected from animals feeding within mangrove forests, e.g., feeding on infauna that had average ??13C values near -26.5???. In contrast, crabs from Lelu had higher ?? 13C and ??34S values, with average values of -21.8 and 7.8???, respectively. These higher isotope values are consistent with increased crab foraging on reef flats and seagrasses. Given that S. serrata have been observed feeding on adjacent reef and seagrass environments on Kosrae, it is likely that they move in and out of the mangroves for feeding. Isotope mixing model results support these conclusions, with the greatest mangrove ecosystem contribution to S. serrata diet occurring in the largest mangrove forests. Conserving larger island mangrove forests (> 1 km deep) appears to support crab foraging activities. ?? 2007 Coastal and Estuarine Research Federation.
What is the value and role of academic medicine in the life of its university?
Azziz, Ricardo
2014-02-01
National and global events are rapidly and irrevocably driving transformation in both academia and health care. One result is an increase in the pace of institutional restructuring, consolidations, and mergers, including the melding of academic medical centers (AMCs; i.e., medical schools and their clinical enterprises) with nonmedical universities. Georgia Regents University (GRU) resulted from one such recent consolidation, and the experience at the institution has highlighted the need to answer the question "What is the value and role of academic medicine and an AMC in the life and transformation of its university?" In attempting to answer this question, the author first contrasts the cultural features of academic medicine and nonmedical faculty and leaders, as observed from the GRU experience, which might be useful for leaders of other institutions of higher education. His analysis suggests that academic medicine is currently significantly insulated from the larger university, and that this segregation or siloing represents a lost opportunity for both the AMC and the university at large. The author's experience suggests that fostering greater synergy between the university and its AMC adds significant value, and that such synergy better ensures the ability of those universities with an AMC to undertake and meet future transformative challenges. Strategies should be proactively developed both to enhance academic medicine leaders' engagement with, exposure to, and education regarding the operations and challenges of higher education and the broader university, and, likewise, to increase nonmedical faculty's understanding of and experience with the value and unique challenges of academic medicine.
NASA Astrophysics Data System (ADS)
Passos, Tassia R. G.; Artur, Adriana G.; Nóbrega, Gabriel N.; Otero, Xosé L.; Ferreira, Tiago O.
2016-06-01
The performance of the Walkley-Black wet oxidation chemical method for soil organic carbon (SOC) determination in coastal wetland soils (mangroves, coastal lagoons, and hypersaline tidal flats) was evaluated in the state of Ceará along the semiarid coast of Brazil, assessing pyrite oxidation and its effects on soil C stock (SCS) quantification. SOC determined by the chemical oxidation method (CWB) was compared to that assessed by means of a standard elemental analyzer (CEA) for surficial samples (<30 cm depth) from the three wetland settings. The pyrite fraction was quantified in various steps of the chemical oxidation method, evaluating the effects of pyrite oxidation. Regardless of the method used, and consistent with site-specific physicochemical conditions, higher pyrite and SOC contents were recorded in the mangroves, whereas lower values were found in the other settings. CWB values were higher than CEA values. Significant differences in SCS calculations based on CWB and CEA were recorded for the coastal lagoons and hypersaline tidal flats. Nevertheless, the CWB and CEA values were strongly correlated, indicating that the wet oxidation chemical method can be used in such settings. In contrast, the absence of correlation for the mangroves provides evidence of the inadequacy of this method for these soils. Air drying and oxidation decrease the pyrite content, with larger effects rooted in oxidation. Thus, the wet oxidation chemical method is not recommended for mangrove soils, but seems appropriate for SOC/SCS quantification in hypersaline tidal flat and coastal lagoon soils characterized by lower pyrite contents.
Fujita, Daishi; Takahashi, Masao; Doi, Kent; Abe, Mitsuru; Tazaki, Junichi; Kiyosue, Arihiro; Myojo, Masahiro; Ando, Jiro; Fujita, Hideo; Noiri, Eisei; Sugaya, Takeshi; Hirata, Yasunobu; Komuro, Issei
2015-05-01
Urinary liver-type fatty acid-binding proteins (uL-FABP) have recently been recognized as a useful biomarker for predicting contrast-induced nephropathy. Although accumulating studies have evaluated short-term outcomes, its prognostic value for long-term renal prognosis in patients undergoing coronary angiography (CAG) has not been fully examined. This study aimed to evaluate the predictive value of uL-FABP for long-term renal outcome in patients with ischemic heart disease (IHD). Consecutive 24 patients with impaired renal function (serum creatinine >1.2 mg/dL) who underwent CAG were enrolled. uL-FABP was measured before CAG, 24 and 48 h after CAG. The changes in estimated glomerular filtration rate (eGFR) throughout CAG and at 1 year later were compared with the uL-FABP levels. The patients with a greater decrease in eGFR 1 year later had higher uL-FABP levels at all points, but only the value at 48 h after CAG reached statistical significance (lower vs. higher decreased eGFR group, 4.61 ± 3.87 vs. 17.71 ± 12.96; P < 0.01). Measurement of uL-FABP at 48 h after CAG (48h-uL-FABP) showed better correlation with the change in eGFR (pre-CAG uL-FABP vs. 48h-uL-FABP: R = 0.27, P = 0.20 vs. R = 0.65, P < 0.01). Moreover, the high-pre and high-48h-uL-FABP group showed a significantly larger decrease in eGFR compared with the high-pre and low-48h-uL-FABP group (change in eGFR; 8.12 ± 4.06 vs. 1.25 ± 2.23 mL/min/1.73 m2, P < 0.01), although the baseline eGFR levels were similar between these two groups. In this pilot study, measurement of uL-FABP levels at 48 h after CAG may be useful in detecting renal damage, and in predicting 1-year renal outcome in IHD patients undergoing CAG.
Wang, Xue; Lu, Yi; Zhang, Xiaoxia; Ji, Taotao; Liu, Kun; Ye, Xinjian; Bai, Guanghui; Yan, Zhihan
2015-01-20
To comparatively analyze the dynamic contrast-enhanced (DCE) characteristics and its clinical value between stage-I endometrial carcinomas versus polyps with 3.0T magnetic resonance imaging (MRI). A retrospective analysis was performed for DCE-MRI manifestation in 27 patients with histopathologically proved endometrial masses. There were stage-I endometrial carcinomas (n = 14) and polyps (n = 13). The signal intensity of solid component was measured and time-intensity curves (TIC) was obtained. TIC of lesions were divided into 4 subtypes. The time-to-peak (TTP) and signal intensity (SI) were determined from TICs. The arterial phase relative signal increase ratio (ARSIR), maximal relative signal increase ratio (MRSIR), signal enhancement ratio (SER) and signal intensity difference values (D) of each phase were calculated based on TIC curves respectively. The TIC of 14 stage-I endometrial carcinomas included type I (n = 4), type II (n = 6) and type IV (n = 4). The TIC of 13 polyps included type III (n = 3) and type IV (n = 10). The D values in each phase of 14 stage-I endometrial carcinomas were lower than normal muscle layers. There were statistic differences (P < 0.05) of each phase including 32, 48, 64, 109, 154, 199 s. For stage-I endometrial carcinomas, MRSIR and TTP were lower (P < 0.01) than normal muscle layers while SER was higher (P < 0.01) than normal muscle layers . The each phase of D of stage-I endometrial carcinomas were lower than polyps, and there were statistic differences (P < 0.05) of each phase including 32, 48, 64, 109, 154, 199 s. The MRSIR and TTP of stage-I endometrial carcinomas were lower (P < 0.01) than those of polyps while SER was higher (P < 0.01) than polyps. DCE-MRI can reflect enhanced features of stage-I endometrial carcinomas and polyps during different phases quantitatively. Parameters of DCE-MR and TIC are helpful in the diagnosis and differential diagnosis of stage-I endometrial carcinomas versus polyps.