Ishida, Masahiro; Takeuchi, Hiroyuki; Endo, Hiromi; Yamaguchi, Jun-Ichi
2015-12-01
In vitro skin permeation studies have been commonly conducted to predict in vivo permeability for the development of transdermal therapeutic systems (TTSs). We clarified the impact of humidity on in vitro human skin permeation of two TTSs having different breathability and then elucidated the predictability of in vivo permeability based on in vitro experimental data. Nicotinell(®) TTS(®) 20 and Frandol(®) tape 40mg were used as model TTSs in this study. The in vitro human skin permeation experiments were conducted under humidity levels similar to those used in clinical trials (approximately 50%) as well as under higher humidity levels (approximately 95%). The skin permeability values of drugs at 95% humidity were higher than those at 50% humidity. The time profiles of the human plasma concentrations after TTS application fitted well with the clinical data when predicted based on the in vitro permeation parameters at 50% humidity. On the other hand, those profiles predicted based on the parameters at 95% humidity were overestimated. The impact of humidity was higher for the more breathable TTS; Frandol(®) tape 40mg. These results show that in vitro human skin permeation experiments should be investigated under realistic clinical humidity levels especially for breathable TTSs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Winkler, Jon; Munk, Jeffrey; Woods, Jason
2018-04-01
Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity,more » and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jon; Munk, Jeffrey; Woods, Jason
Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity,more » and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.« less
Isolated Sub-Dehumidification Strategies in Large Supermarkets and Grocery Stores
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A; Sharma, Vishaldeep
2011-10-01
The objective of this project was to determine the potential energy savings associated with reducing the relative humidity in the vicinity of refrigerated display cases in supermarkets, as compared to the widely accepted current practice of maintaining a relatively higher and uniform humidity level throughout the entire supermarket. Existing and new strategies for maintaining lower relative humidity levels near the vicinity of refrigerated display cases were analyzed to determine their effectiveness and limits of application.
Atalla, Mohamed Mabrouk; Hassanein, Naziha Mohamed; El-Beih, Ahmed Atef; Youssef, Youssef Abdel-ghany
2003-02-01
Four different Aspergilli (Aspergillus oryzae, A. parasiticus, A. terreus and A. versicolor) were grown on wheat grains underdifferent degrees of relative humidity 14, 50, 74, 80 and 90%. Samples of wheat grains were taken monthly for a period of six months and examined for mycotoxin production. A. oryzae was found to produce aflatoxins B1, B2, zearalenone, DON and T-2 toxins under elevated degrees of humidity and prolonged periods of storage. A. parasiticus produced aflatoxins B1, G1, NIV, DON and T-2 toxins in high concentrations during a period of not more than three months storage at 14% relative humidity; at an increased level of relative humidity of 74% ochratoxin A, zearalenone and sterigmatocystin were also produced at high levels. The isolate was drastic in toxin production. A. terrus produced toxins at 14% relative humidity (aflatoxin G2 and DON) at levels much higher than any other prevalent degrees of humidity. A. versicolor is highly sensitive to relative humidity and grain moisture content It produced aflatoxins B1, G1, NIV and DON at a relative humidity of 50% and another toxins (aflatoxin G2, ochratoxins A, B and zearalenone) at 74%. The microorganism can be considered a trichothecene producer under suitable relative humidity.
Fabrication and Evaluation of a Graphene Oxide-Based Capacitive Humidity Sensor.
Feng, Jinfeng; Kang, Xiaoxu; Zuo, Qingyun; Yuan, Chao; Wang, Weijun; Zhao, Yuhang; Zhu, Limin; Lu, Hanwei; Chen, Juying
2016-03-01
In this study, a CMOS compatible capacitive humidity sensor structure was designed and fabricated on a 200 mm CMOS BEOL Line. A top Al interconnect layer was used as an electrode with a comb/serpent structure, and graphene oxide (GO) was used as sensing material. XRD analysis was done which shows that GO sensing material has a strong and sharp (002) peak at about 10.278°, whereas graphite has (002) peak at about 26°. Device level CV and IV curves were measured in mini-environments at different relative humidity (RH) level, and saturated salt solutions were used to build these mini-environments. To evaluate the potential value of GO material in humidity sensor applications, a prototype humidity sensor was designed and fabricated by integrating the sensor with a dedicated readout ASIC and display/calibration module. Measurements in different mini-environments show that the GO-based humidity sensor has higher sensitivity, faster recovery time and good linearity performance. Compared with a standard humidity sensor, the measured RH data of our prototype humidity sensor can match well that of the standard product.
Roberts, Calum T; Kortekaas, Rebecca; Dawson, Jennifer A; Manley, Brett J; Owen, Louise S; Davis, Peter G
2016-05-01
Heating and humidification of inspired gases is routine during neonatal non-invasive respiratory support. However, little is known about the temperature and humidity delivered to the upper airway. The International Standards Organization (ISO) specifies that for all patients with an artificial airway humidifiers should deliver ≥33 g/m(3) absolute humidity (AH). We assessed the oropharyngeal temperature and humidity during different non-invasive support modes in a neonatal manikin study. Six different modes of non-invasive respiratory support were applied at clinically relevant settings to a neonatal manikin, placed in a warmed and humidified neonatal incubator. Oropharyngeal temperature and relative humidity (RH) were assessed using a thermohygrometer. AH was subsequently calculated. Measured temperature and RH varied between devices. Bubble and ventilator continuous positive airway pressure (CPAP) produced temperatures >34°C and AH >38 g/m(3). Variable flow CPAP resulted in lower levels of AH than bubble or ventilator CPAP, and AH decreased with higher gas flow. High-flow (HF) therapy delivered by Optiflow Junior produced higher AH with higher gas flow, whereas with Vapotherm HF the converse was true. Different non-invasive devices deliver inspiratory gases of variable temperature and humidity. Most AH levels were above the ISO recommendation; however, with some HF and variable flow CPAP devices at higher gas flow this was not achieved. Clinicians should be aware of differences in the efficacy of heating and humidification when choosing modes of non-invasive respiratory support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Weather-Dependent Risk for Legionnaires' Disease, United States.
Simmering, Jacob E; Polgreen, Linnea A; Hornick, Douglas B; Sewell, Daniel K; Polgreen, Philip M
2017-11-01
Using the Nationwide Inpatient Sample and US weather data, we estimated the probability of community-acquired pneumonia (CAP) being diagnosed as Legionnaires' disease (LD). LD risk increases when weather is warm and humid. With warm weather, we found a dose-response relationship between relative humidity and the odds for LD. When the mean temperature was 60°-80°F with high humidity (>80.0%), the odds for CAP being diagnosed with LD were 3.1 times higher than with lower levels of humidity (<50.0%). Thus, in some regions (e.g., the Southwest), LD is rarely the cause of hospitalizations. In other regions and seasons (e.g., the mid-Atlantic in summer), LD is much more common. Thus, suspicion for LD should increase when weather is warm and humid. However, when weather is cold, dry, or extremely hot, empirically treating all CAP patients for LD might contribute to excessive antimicrobial drug use at a population level.
Humidity data for 9975 shipping packages with cane fiberboard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
The 9975 surveillance program is developing a technical basis to support extending the storage period of 9975 packages in K-Area Complex beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Direct measurements of humidity and fiberboard moisture content have been made on two test packages with cane fiberboard and varying internal heat levels from 0 up to 19W. With an internalmore » heat load, a temperature gradient in the fiberboard assembly leads to varying relative humidity in the air around the fiberboard. However, the absolute humidity tends to remain approximately constant throughout the package. The moisture content of fiberboard varies under the influence of several phenomena. Changes in local fiberboard temperature (from an internal heat load) can cause fiberboard moisture changes through absorption or evaporation. Fiberboard degradation at elevated temperature will produce water as a byproduct. And the moisture level within the package is constantly seeking equilibrium with that of the surrounding room air, which varies on a daily and seasonal basis. One indicator of the moisture condition within a 9975 package might be obtained by measuring the relative humidity in the upper air space, by inserting a humidity probe through a caplug hole. However, the data indicate that for the higher internal heat loads (15 and 19 watts), a large variation in internal moisture conditions produces little or no variation in the air space relative humidity. Therefore, this approach does not appear to be sensitive to fiberboard moisture variations at the higher heat loads which are of most interest to maintaining fiberboard integrity.« less
Cold Spots in Neonatal Incubators Are Hot Spots for Microbial Contamination▿
de Goffau, Marcus C.; Bergman, Klasien A.; de Vries, Hendrik J.; Meessen, Nico E. L.; Degener, John E.; van Dijl, Jan Maarten; Harmsen, Hermie J. M.
2011-01-01
Thermal stability is essential for the survival and well-being of preterm neonates. This is achieved in neonatal incubators by raising the ambient temperature and humidity to sufficiently high levels. However, potentially pathogenic microorganisms also can thrive in such warm and humid environments. We therefore investigated whether the level of microbial contamination (i.e., the bacterial load) inside neonatal incubators can be predicted on the basis of their average temperature and relative humidity settings, paying special attention to local temperature differences. Swab samples were taken from the warmest and coldest spots found within Caleo incubators, and these were plated to determine the number of microbial CFU per location. In incubators with high average temperature (≥34°C) and relative humidity (≥60%) values, the level of microbial contamination was significantly higher at cold spots than at hot spots. This relates to the fact that the local equilibrium relative humidity at cold spots is sufficiently high to sustain microbial growth. The abundance of staphylococci, which are the main causative agents of late-onset sepsis in preterm neonates, was found to be elevated significantly in cold areas. These findings can be used to improve basic incubator hygiene. PMID:22003021
Johnston, James D.; Tuttle, Steven C.; Nelson, Morgan C.; Bradshaw, Rebecca K.; Hoybjerg, Taylor G.; Johnson, Julene B.; Kruman, Bryce A.; Orton, Taylor S.; Cook, Ryan B.; Eggett, Dennis L.; Weber, K. Scott
2016-01-01
Concerns about energy consumption and climate change make residential evaporative coolers a popular alternative to central air conditioning in arid and semi-arid climates. However, evaporative coolers have been shown to significantly increase indoor relative humidity and dust mite allergen levels in some studies, while showing no association in other studies. Improved measurement of temporal fluctuations in indoor relative humidity may help identify factors that promote mite growth in homes in dry climates. Dust samples and continuous indoor relative humidity measurements were collected from homes with central air conditioning and homes with evaporative coolers in Utah. Samples were collected over two seasons, winter/spring (Jan–Apr) and summer (July–Sept), 2014. Dust samples were analyzed for Der p 1 and Der f 1 using a two-site monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA) analysis. Housing characteristics including age of home, occupant density, and age of mattresses, furniture, and carpeting were also measured. Positive Der p 1 or Der f 1 samples were found in 25.0% of the homes and there was no difference in mean allergen levels by type of air conditioning. Indoor relative humidity was significantly higher in homes with evaporative coolers compared to those with central air conditioning during the summer. Homes with evaporative coolers also spent significantly more time during summer above 55.0% and 65.0% relative humidity compared to central air homes, but not above 75.0%. Findings from this study suggest that increased humidity from evaporative coolers may not be sufficient to exceed the critical equilibrium humidity or maintain humidity excursions for sufficient duration in relatively larger single-family homes in semi-arid climates to support mite growth and reproduction. PMID:26808528
Johnston, James D; Tuttle, Steven C; Nelson, Morgan C; Bradshaw, Rebecca K; Hoybjerg, Taylor G; Johnson, Julene B; Kruman, Bryce A; Orton, Taylor S; Cook, Ryan B; Eggett, Dennis L; Weber, K Scott
2016-01-01
Concerns about energy consumption and climate change make residential evaporative coolers a popular alternative to central air conditioning in arid and semi-arid climates. However, evaporative coolers have been shown to significantly increase indoor relative humidity and dust mite allergen levels in some studies, while showing no association in other studies. Improved measurement of temporal fluctuations in indoor relative humidity may help identify factors that promote mite growth in homes in dry climates. Dust samples and continuous indoor relative humidity measurements were collected from homes with central air conditioning and homes with evaporative coolers in Utah. Samples were collected over two seasons, winter/spring (Jan-Apr) and summer (July-Sept), 2014. Dust samples were analyzed for Der p 1 and Der f 1 using a two-site monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA) analysis. Housing characteristics including age of home, occupant density, and age of mattresses, furniture, and carpeting were also measured. Positive Der p 1 or Der f 1 samples were found in 25.0% of the homes and there was no difference in mean allergen levels by type of air conditioning. Indoor relative humidity was significantly higher in homes with evaporative coolers compared to those with central air conditioning during the summer. Homes with evaporative coolers also spent significantly more time during summer above 55.0% and 65.0% relative humidity compared to central air homes, but not above 75.0%. Findings from this study suggest that increased humidity from evaporative coolers may not be sufficient to exceed the critical equilibrium humidity or maintain humidity excursions for sufficient duration in relatively larger single-family homes in semi-arid climates to support mite growth and reproduction.
Zeng, Jie; Zhang, Xuehai; Yang, Jun; Bao, Junzhe; Dear, Keith; Liu, Qiyong; Lin, Shao; Lin, Aihua; Huang, Cunrui
2017-01-01
Background: The evidence of increased mortality attributable to extreme temperatures is widely characterized in climate-health studies. However, few of these studies have examined the role of humidity on temperature-mortality association. We investigated the joint effect between temperature and humidity on cardiovascular disease (CVD) mortality in Zhejiang Province, China. Methods: We collected data on daily meteorological and CVD mortality from 11 cities in Zhejiang Province during 2010–2013. We first applied time-series Poisson regression analysis within the framework of distributed lag non-linear models to estimate the city-specific effect of temperature and humidity on CVD mortality, after controlling for temporal trends and potential confounding variables. We then applied a multivariate meta-analytical model to pool the effect estimates in the 11 cities to generate an overall provincial estimate. The joint effects between them were calculated by the attributable fraction (AF). The analyses were further stratified by gender, age group, education level, and location of cities. Results: In total, 120,544 CVD deaths were recorded in this study. The mean values of temperature and humidity were 17.6 °C and 72.3%. The joint effect between low temperature and high humidity had the greatest impact on the CVD death burden over a lag of 0–21 days with a significant AF of 31.36% (95% eCI: 14.79–38.41%), while in a condition of low temperature and low humidity with a significant AF of 16.74% (95% eCI: 0.89, 24.44). The AFs were higher at low temperature and high humidity in different subgroups. When considering the levels of humidity, the AFs were significant at low temperature and high humidity for males, youth, those with a low level of education, and coastal area people. Conclusions: The combination of low temperature and high humidity had the greatest impact on the CVD death burden in Zhejiang Province. This evidence has important implications for developing CVD interventions. PMID:29135955
Zeng, Jie; Zhang, Xuehai; Yang, Jun; Bao, Junzhe; Xiang, Hao; Dear, Keith; Liu, Qiyong; Lin, Shao; Lawrence, Wayne R; Lin, Aihua; Huang, Cunrui
2017-11-14
Background : The evidence of increased mortality attributable to extreme temperatures is widely characterized in climate-health studies. However, few of these studies have examined the role of humidity on temperature-mortality association. We investigated the joint effect between temperature and humidity on cardiovascular disease (CVD) mortality in Zhejiang Province, China. Methods : We collected data on daily meteorological and CVD mortality from 11 cities in Zhejiang Province during 2010-2013. We first applied time-series Poisson regression analysis within the framework of distributed lag non-linear models to estimate the city-specific effect of temperature and humidity on CVD mortality, after controlling for temporal trends and potential confounding variables. We then applied a multivariate meta-analytical model to pool the effect estimates in the 11 cities to generate an overall provincial estimate. The joint effects between them were calculated by the attributable fraction (AF). The analyses were further stratified by gender, age group, education level, and location of cities. Results : In total, 120,544 CVD deaths were recorded in this study. The mean values of temperature and humidity were 17.6 °C and 72.3%. The joint effect between low temperature and high humidity had the greatest impact on the CVD death burden over a lag of 0-21 days with a significant AF of 31.36% (95% eCI: 14.79-38.41%), while in a condition of low temperature and low humidity with a significant AF of 16.74% (95% eCI: 0.89, 24.44). The AFs were higher at low temperature and high humidity in different subgroups. When considering the levels of humidity, the AFs were significant at low temperature and high humidity for males, youth, those with a low level of education, and coastal area people. Conclusions : The combination of low temperature and high humidity had the greatest impact on the CVD death burden in Zhejiang Province. This evidence has important implications for developing CVD interventions.
Navy Expeditionary Technology Transition Program (NETTP)
2012-03-02
water vapor from feed air using a zeolite membrane •Temperature/Humidity levels can be met in warm, humid climates without reheating •Allows higher...UNCLASSIFIED, Distribution Unlimited Modular Thermal Hub •Small, efficient absorption cooling •Energy source: Combustion, low- grade waste heat, solar... thermal energy •Reversible operation enables space cooling and heating, and water heating •Modular cooling and heating unit •Monolithic packaging offers
NASA Astrophysics Data System (ADS)
Karimov, Kh. S.; Fatima, Noshin; Sulaiman, Khaulah; Mahroof Tahir, M.; Ahmad, Zubair; Mateen, A.
2015-03-01
The humidity sensing properties of the thin films of an organic semiconductor material orange dye (OD) and its composite with CNTs deposited at high gravity conditions have been reported. Impedance, phase angle, capacitance and dissipation of the samples were measured at 1 kHz and room temperature conditions. The impedance decreases and capacitance increases with an increase in the humidity level. It was found that the sensitivity of the OD-based thin film samples deposited at high gravity condition is higher than the samples deposited at low gravity condition. The impedances and capacitance sensitivities of the of the samples deposited under high gravity condition are 6.1 times and 1.6 times higher than the films deposited under low gravity condition.
Öztürk, Sadullah; Kösemen, Arif; Şen, Zafer; Kılınç, Necmettin; Harbeck, Mika
2016-01-01
Poly(3-methylthiophene) (PMeT) thin films were electrochemically deposited on quartz crystal microbalance QCM transducers to investigate their volatile organic compound (VOC) sensing properties depending on ambient conditions. Twelve different VOCs including alcohols, ketones, chlorinated compounds, amines, and the organosphosphate dimethyl methylphosphonate (DMMP) were used as analytes. The responses of the chemical sensors against DMMP were the highest among the tested analytes; thus, fabricated chemical sensors based on PMeT can be evaluated as potential candidates for selectively detecting DMMP. Generally, detection limits in the low ppm range could be achieved. The gas sensing measurements were recorded at various humid air conditions to investigate the effects of the humidity on the gas sensing properties. The sensing performance of the chemical sensors was slightly reduced in the presence of humidity in ambient conditions. While a decrease in sensitivity was observed for humidity levels up to 50% r.h., the sensitivity was nearly unaffected for higher humidity levels and a reliable detection of the VOCs and DMMP was possible with detection limits in the low ppm range. PMID:27023539
Xing, Yanan; Li, Huan; Huang, Liubin; Wu, Huihui; Shen, Hengqing; Chen, Zhongming
2018-04-01
Methacrolein (MACR) is an abundant multifunctional carbonyl compound with high reactivity in the atmosphere. In this study, we investigated the hydroxyl radical initiated oxidation of MACR at various NO/MACR ratios (0 to 4.04) and relative humidities (<3% to 80%) using a flow tube. Meanwhile, a box model based on the Master Chemical Mechanism was performed to test our current understanding of the mechanism. In contrast to the reasonable predictions for hydroxyacetone production, the modeled yields of formaldehyde (HCHO) were twice higher than the experimental results. The discrepancy was ascribed to the existence of unconsidered non-HCHO forming channels in the chemistry of CH 3 C(CH 2 )OO, which account for approx. 50%. In addition, the production of hydroxyacetone and HCHO were affected by water vapor as well as the initial NO/MACR ratio. The yields of HCHO were higher under humid conditions than that under dry condition. The yields of hydroxyacetone were higher under humid conditions at low-NO x level, while lower at high-NO x level. The reasonable explanation for the lower hydroxyacetone yield under humid conditions at high-NO x level is that water vapor promotes the production of methacrolein nitrate in the reaction of HOCH 2 C(CH 3 )(OO)CHO with NO due to the peroxy radical-water complex formation, which was evidenced by calculational results. And the minimum equilibrium constant of this water complex formation was estimated to be 1.89×10 -18 cm 3 /molecule. These results provide new insights into the MACR oxidation mechanism and the effects of water vapor. Copyright © 2017. Published by Elsevier B.V.
A Fast Humidity Sensor Based on Li+-Doped SnO2 One-Dimensional Porous Nanofibers
Yin, Min; Yang, Fang; Wang, Zhaojie; Zhu, Miao; Liu, Ming; Xu, Xiuru; Li, Zhenyu
2017-01-01
One-dimensional SnO2- and Li+-doped SnO2 porous nanofibers were easily fabricated via electrospinning and a subsequent calcination procedure for ultrafast humidity sensing. Different Li dopant concentrations were introduced to investigate the dopant’s role in sensing performance. The response properties were studied under different relative humidity levels by both statistic and dynamic tests. The best response was obtained with respect to the optimal doping of Li+ into SnO2 porous nanofibers with a maximum 15 times higher response than that of pristine SnO2 porous nanofibers, at a relative humidity level of 85%. Most importantly, the ultrafast response and recovery time within 1 s was also obtained with the 1.0 wt % doping of Li+ into SnO2 porous nanofibers at 5 V and at room temperature, benefiting from the co-contributions of Li-doping and the one-dimensional porous structure. This work provides an effective method of developing ultrafast sensors for practical applications—especially fast breathing sensors. PMID:28772895
Gueye, Birahima; Zhang, Yan; Wang, Yujuan; Chen, Yunfei
2015-07-08
The liquid lubrication, thermolubricity and dynamic lubricity due to mechanical oscillations are investigated with an atomic force microscope in ambient environmental conditions with different relative humidity (RH) levels. Experimental results demonstrate that high humidity at low-temperature regime enhances the liquid lubricity while at high-temperature regime it hinders the effect of the thermolubricity due to the formation of liquid bridges. Friction response to the dynamic lubricity in both high- and low-temperature regimes keeps the same trends, namely the friction force decreases with increasing the amplitude of the applied vibration on the tip regardless of the RH levels. An interesting finding is that for the dynamic lubricity at high temperature, high-humidity condition leads to the friction forces higher than that at low-humidity condition while at low temperature the opposite trend is observed. An extended two-dimensional dynamic model accounting for the RH is proposed to interpret the frictional mechanism in ambient conditions.
Relationships among Environment, Climate, and Longevity in China
Huang, Yi; Rosenberg, Mark; Hou, Lingli; Hu, Mengjin
2017-01-01
Human longevity is influenced by environment and nutrition. We considered environmental and nutritional factors relating to longevity in Chinese cities. We found higher 85+/65+ distribution ratios, indicating enhanced longevity, in the coastal and southern regions of China. These areas also featured higher humidity, low standard deviation of monthly temperature, higher levels of selenium (Se) distribution in soil, and greater sea fish consumption. Moderate climate is more conducive to longevity, however, there is no significant difference in longevity between different sub-climatic types within moderate climate; the relation between humidity and longevity is not always positive, the relation between altitude and longevity is not always negative. Nutritional factors like Se and omega-3 fatty acids contained in sea fish were crucial to longevity. In contrast, the consumption of meat and freshwater fish were less related to longevity. Taken together, humidity, altitude, and per capita sea fish consumption, when evaluated via geographically weighted regression, explained 66% and 68% of longevity among Chinese individuals in 2000 and 2010, respectively. Other factors require further discussion. PMID:28991186
Relationships among Environment, Climate, and Longevity in China.
Huang, Yi; Rosenberg, Mark; Hou, Lingli; Hu, Mengjin
2017-10-08
Human longevity is influenced by environment and nutrition. We considered environmental and nutritional factors relating to longevity in Chinese cities. We found higher 85+/65+ distribution ratios, indicating enhanced longevity, in the coastal and southern regions of China. These areas also featured higher humidity, low standard deviation of monthly temperature, higher levels of selenium (Se) distribution in soil, and greater sea fish consumption. Moderate climate is more conducive to longevity, however, there is no significant difference in longevity between different sub-climatic types within moderate climate; the relation between humidity and longevity is not always positive, the relation between altitude and longevity is not always negative. Nutritional factors like Se and omega-3 fatty acids contained in sea fish were crucial to longevity. In contrast, the consumption of meat and freshwater fish were less related to longevity. Taken together, humidity, altitude, and per capita sea fish consumption, when evaluated via geographically weighted regression, explained 66% and 68% of longevity among Chinese individuals in 2000 and 2010, respectively. Other factors require further discussion.
Wu, Jinju; Cheng, Jian; Xu, Zhiwei; Zhao, Kefu; Zhao, Desheng; Xie, Mingyu; Yang, Huihui; Wen, Liying; Li, Kesheng; Su, Hong
2016-10-01
Hand, foot and mouth disease (HFMD) is one of the major infectious diseases among children and remains a health threat, especially among Asian countries. Many epidemiologic studies suggested significant association of air temperature and humidity with childhood HFMD; however, evidence on the temperature effects on childhood HFMD in temperate cities is limited, and the interactive effects of temperature and humidity have not been studied yet. Daily counts of HFMD in children younger than 15 years of age and daily meteorologic variables during 2010 to 2012 were obtained in Hefei, China. A distributed lag nonlinear model was applied to estimate the potential nonlinear association between temperature and childhood HFMD. The interactive effects between temperature and humidity on childhood HFMD were also investigated. Temperature rise was associated with higher risk of childhood HFMD. Within the incubation period of HFMD, temperature rise appeared to have the acute effects on childhood HFMD, and a 5°C increase of temperature at lag 0-6 days was associated with 24.8% (95% confidence interval: 11.94%-39.10%) increase of childhood HFMD. Females and children of 0-4 years of agewere more vulnerable to temperature rise. Notably, there were obvious combined effects between temperature and humidity on childhood HFMD-the risk of childhood HFMD elevated at higher temperature and humidity level. This study provides evidence that temperature and humidity may jointly affect childhood HFMD, and such interactive impact needs to be considered when evaluating the temperature-childhood HFMD relationship.
Niglas, Aigar; Kupper, Priit; Tullus, Arvo; Sellin, Arne
2014-01-01
An increase in average air temperature and frequency of rain events is predicted for higher latitudes by the end of the 21st century, accompanied by a probable rise in air humidity. We currently lack knowledge on how forest trees acclimate to rising air humidity in temperate climates. We analysed the leaf gas exchange, sap flow and growth characteristics of hybrid aspen (Populus tremula × P. tremuloides) trees growing at ambient and artificially elevated air humidity in an experimental forest plantation situated in the hemiboreal vegetation zone. Humidification manipulation did not affect the photosynthetic capacity of plants, but did affect stomatal responses: trees growing at elevated air humidity had higher stomatal conductance at saturating photosynthetically active radiation (gs sat) and lower intrinsic water-use efficiency (IWUE). Reduced stomatal limitation of photosynthesis in trees grown at elevated air humidity allowed slightly higher net photosynthesis and relative current-year height increments than in trees at ambient air humidity. Tree responses suggest a mitigating effect of higher air humidity on trees under mild water stress. At the same time, trees at higher air humidity demonstrated a reduced sensitivity of IWUE to factors inducing stomatal closure and a steeper decline in canopy conductance in response to water deficit, implying higher dehydration risk. Despite the mitigating impact of increased air humidity under moderate drought, a future rise in atmospheric humidity at high latitudes may be disadvantageous for trees during weather extremes and represents a potential threat in hemiboreal forest ecosystems. PMID:24887000
On the effects of higher alcohols on red wine aroma.
de-la-Fuente-Blanco, Arancha; Sáenz-Navajas, María-Pilar; Ferreira, Vicente
2016-11-01
This work aims to assess the aromatic sensory contribution of the four most relevant wine higher alcohols (isobutanol, isoamyl alcohol, methionol and β-phenylethanol) on red wine aroma. The four alcohols were added at two levels of concentration, within the natural range of occurrence, to eight different wine models (WM), close reconstitutions of red wines differing in levels of fruity (F), woody (W), animal (A) or humidity (H) notes. Samples were submitted to discriminant and descriptive sensory analysis. Results showed that the contribution of methionol and β-phenylethanol to wine aroma was negligible and confirmed the sensory importance of the pair isobutanol-isoamyl alcohol. Sensory effects were only evident in WM containing intense aromas, demonstrating a strong dependence on the aromatic context. Higher alcohols significantly suppress strawberry/lactic/red fruity, coconut/wood/vanilla and humidity/TCA notes, but not the leather/animal/ink note. The spirit/alcoholic/solvent character generated by higher alcohols has been shown to be wine dependent. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kuwagata, Tsuneo; Ishikawa-Sakurai, Junko; Hayashi, Hidehiro; Nagasuga, Kiyoshi; Fukushi, Keiko; Ahamed, Arifa; Takasugi, Katsuko; Katsuhara, Maki; Murai-Hatano, Mari
2012-08-01
The effects of low air humidity and low root temperature (LRT) on water uptake, growth and aquaporin gene expression were investigated in rice plants. The daily transpiration of the plants grown at low humidity was 1.5- to 2-fold higher than that at high humidity. LRT at 13°C reduced transpiration, and the extent was larger at lower humidity. LRT also reduced total dry matter production and leaf area expansion, and the extent was again larger at lower humidity. These observations suggest that the suppression of plant growth by LRT is associated with water stress due to decreased water uptake ability of the root. On the other hand, the net assimilation rate was not affected by low humidity and LRT, and water use efficiency was larger for LRT. We found that low humidity induced coordinated up-regulation of many PIP and TIP aquaporin genes in both the leaves and the roots. Expression levels of two root-specific aquaporin genes, OsPIP2;4 and OsPIP2;5, were increased significantly after 6 and 13 d of LRT exposure. Taken together, we discuss the possibility that aquaporins are part of an integrated response of this crop to low air humidity and LRT.
Yin, Qian; Wang, Jinfeng
2018-05-31
Although many studies have examined the correlation between temperature and mortality from cardiovascular diseases (CVD), other meteorological factors, such as relative humidity, may modify the relationship. Yet the studies on this aspect are relatively few. We chose a heat index (HI, which is an index that combines air temperature and relative humidity) as an alternative indicator of temperature, and used a distributed lag nonlinear model (DLNM) to analyze the combined effects of temperature and relative humidity on CVD mortality among all of the Beijing residents and subsociodemographic groups by age, sex, and occupation. The heat index can better reflect the human-perceived temperature when relative humidity is combined with air temperature. The results show that females, elderly people, and outdoor workers have higher vulnerability levels in regard to a high heat index. The strongest effect of heat index was found among females, for which the highest mortality risk was about 2.4 (95% CI 1.8-3) times greater than the lowest mortality risk. In addition, we found that there is a significant interaction effect of temperature and relative humidity on CVD mortality. The impact of extreme high temperature may be exacerbated by increases in humidity. Based on these results, we draw the risk level map of CVD death under different temperatures and grades of relative humidity. These findings may aid governments in the development of more accurate heat alerts and the provision of measures to prevent or reduce temperature-related deaths.
Ambient ammonia measurements using laser photo-acoustic spectroscopy
NASA Technical Reports Server (NTRS)
Aldridge, M. D., III; Copeland, G. E.; Harward, C. N.
1981-01-01
Ammonia concentrations reached minimal levels (approximately 0.1 ppb) in early winter, followed by a sudden later winter increase. A direct relationship between ambient ammonia levels and air temperature was inferred from the data (linear correlation coefficient r=0.53). Ammonia concentrations were determined to be directly related to the absolute humidity of the air (r=0.72); a weaker relationship between ammonia concentrations and relative humidity was discovered (r=0.37). The data also indicated that ammonia levels were generally higher within continental air masses than those of maritime origin. Soil parameters such as pH and moisture content were found to have a major bearing on the release of gaseous ammonia from soils in the region.
Poopalalingam, R; Goh, M H; Chan, Y W
2002-11-01
The aim of the study was to measure the humidity and temperature of the inspired gas in a circle absorber system at fresh gas flows of 11/min and 31/min and assess the need of a heat and moisture exchanger (HME). This prospective randomised controlled study received the Hospital Ethics Committee approval and informed consent. Forty adult ASA 1 and 11 patients were randomised into four groups to receive with or without HME fresh gas flow of 1L/min or 3L/min. Temperature and the relative humidity readings were taken at the start and every 10 minutes for the first hour of anaesthesia. There was a significantly higher relative humidity, absolute humidity and temperatures of the inspired gases at fresh gas flow of 1L/min and 3L/min with a HME compared to 3L/min without HME. Patients receiving fresh gas flows of lL/min had higher relative and absolute humidity than patients with fresh gas flows of 3L/min. However, the addition of the HME improved the absolute and relative humidity of the inspired gas in patients receiving fresh gas flow of 3l/min to a comparable level. However, the addition of a HME to a fresh gas flow of 1L/min did not significantly improve the humidity of the inspired gas. This suggests that the inherent humidifying property of the circle system at low fresh gas flow of 1L/min was sufficient in short surgeries lasting less than one hour and that the addition of a HME may not be necessary.
Angelon-Gaetz, K A; Richardson, D B; Lipton, D M; Marshall, S W; Lamb, B; LoFrese, T
2015-12-01
Both high and low indoor relative humidity (RH) directly impact Indoor Air Quality (IAQ), an important school health concern. Prior school studies reported a high prevalence of mold, roaches, and water damage; however, few examined associations between modifiable classroom factors and RH, a quantitative indicator of dampness. We recorded RH longitudinally in 134 North Carolina classrooms (n = 9066 classroom-days) to quantify the relationships between modifiable classroom factors and average daily RH below, within, or above levels recommended to improve school IAQ (30-50% or 30-60% RH). The odds of having high RH (>60%) were 5.8 [95% Confidence Interval (CI): 2.9, 11.3] times higher in classrooms with annual compared to quarterly heating, ventilating, and air-conditioning (HVAC) system maintenance and 2.5 (95% CI: 1.5, 4.2) times higher in classrooms with HVAC economizers compared to those without economizers. Classrooms with direct-expansion split systems compared to chilled water systems had 2.7 (95% CI: 1.7, 4.4) times higher odds of low RH (<30%). When unoccupied, classrooms with thermostat setbacks had 3.7 (95% CI: 1.7, 8.3) times the odds of high RH (>60%) of those without setbacks. This research suggests actionable decision points for school design and maintenance to prevent high or low classroom RH. This study combines longitudinal measurements of classroom relative humidity with school inspection data from several schools to describe the problem of relative humidity control in schools. Our findings on how maintenance and mechanical factors affect classroom humidity provide suggestions on building operations policies and heating, ventilating, and air-conditioning (HVAC) design considerations that may improve classroom relative humidity control. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Rapid effects of humidity acclimation on stress resistance in Drosophila melanogaster.
Aggarwal, Dau Dayal; Ranga, Poonam; Kalra, Bhawna; Parkash, Ravi; Rashkovetsky, Eugenia; Bantis, Leonidas E
2013-09-01
We tested the hypothesis whether developmental acclimation at ecologically relevant humidity regimes (40% and 75% RH) affects desiccation resistance of pre-adults (3rd instar larvae) and adults of Drosophila melanogaster Meigen (Diptera: Drosophilidae). Additionally, we untangled whether drought (40% RH) acclimation affects cold-tolerance in the adults of D. melanogaster. We observed that low humidity (40% RH) acclimated individuals survived significantly longer (1.6-fold) under lethal levels of desiccation stress (0-5% RH) than their counter-replicates acclimated at 75% RH. In contrast to a faster duration of development of 1st and 2nd instar larvae, 3rd instar larvae showed a delayed development at 40% RH as compared to their counterparts grown at 75% RH. Rearing to low humidity conferred an increase in bulk water, hemolymph content and dehydration tolerance, consistent with increase in desiccation resistance for replicates grown at 40% as compared to their counterparts at 75% RH. Further, we found a trade-off between the levels of carbohydrates and body lipid reserves at 40% and 75% RH. Higher levels of carbohydrates sustained longer survival under desiccation stress for individuals developed at 40% RH than their congeners at 75% RH. However, the rate of carbohydrate utilization did not differ between the individuals reared at these contrasting humidity regimes. Interestingly, our results of accelerated failure time (AFT) models showed substantial decreased death rates at a series of low temperatures (0, -2, or -4°C) for replicates acclimated at 40% RH as compared to their counter-parts at 75% RH. Therefore, our findings indicate that development to low humidity conditions constrained on multiple physiological mechanisms of water-balance, and conferred cross-tolerance towards desiccation and cold stress in D. melanogaster. Finally, we suggest that the ability of generalist Drosophila species to tolerate fluctuations in humidity might aid in their existence and abundance under expected changes in moisture level in course of global climate change. Copyright © 2013 Elsevier Inc. All rights reserved.
Effects of atmospheric temperature and humidity on outbreak of diseases.
Choi, Sung Hyuk; Lee, Sung Woo; Hong, Yun Sik; Kim, Su Jin; Kim, Nak Hoon
2007-12-01
The present study aimed to determine the plausibility of forecasting the outbreak of diseases based on the weather by analysing the impact of atmospheric temperature and humidity on the occurrence of different diseases. The subjects of the present study were the 30,434 patients who visited the ED in 1 year from 1 February 2005 to 3 February 2006. The present study analysed the correlation between the daily number of patients who suffered from 22 types of traumatic and non-traumatic diseases and the data on atmospheric temperature and humidity provided by the Korea Meteorological Administration. With traumatic disease, the occurrence tended to increase in proportion to the rise in temperature and humidity; whereas with non-traumatic disease, the occurrence tended to increase according to the rise in temperature, irrespective of humidity changes. The research on the impact of atmospheric temperature and humidity on different diseases revealed a high level of distribution of most diseases in an environment with high temperature and humidity. However, in the case of pulmonary diseases and trauma to multiple body regions, the occurrence increased in environments with low temperature and high humidity for pulmonary diseases, and with low temperature and low humidity for trauma to multiple body regions. Most diseases tend to increase in proportion to the rise in atmospheric temperature whereas being less affected by humidity. However, an increase in humidity in an optimum range of atmospheric temperature (12 degrees C or higher) triggers an increase in the occurrence of diseases.
NASA Astrophysics Data System (ADS)
Jiménez-Moreno, Gonzalo; García-Alix, Antonio; Hernández-Corbalán, María Dolores; Anderson, R. Scott; Delgado-Huertas, Antonio
2013-03-01
Detailed pollen, charcoal, isotope and magnetic susceptibility data from an alpine lake sediment core from Sierra Nevada, southern Spain record changes in vegetation, fire history and lake sedimentation since ca. 4100 cal yr BP. The proxies studied record an arid period from ca. 3800 to 3100 cal yr BP characterized by more xerophytic vegetation and lower lake levels. A humid period is recorded between ca. 3100 and 1850 cal yr BP, which occurred in two steps: (1) an increase in evergreen Quercus between 3100 and 2500 cal yr BP, indicating milder conditions than previously and (2) an increase in deciduous Quercus and higher lake levels, between ca. 2500 and 1850 cal yr BP, indicating a further increase in humidity and reduction in seasonal contrast. Humid maxima occurred during the Roman Humid Period, previously identified in other studies in the Mediterranean region. Intensified fire activity at this time could be related to an increase in fuel load and/or in human disturbance. An arid period subsequently occurred between 1850 and 650 cal yr BP, though a decrease in Quercus and an increase in xerophytes. The alternation of persistent North Atlantic Oscillation modes probably played an important role in controlling these humid-arid cycles.
Berman, A; Horovitz, Talia; Kaim, M; Gacitua, H
2016-10-01
The combined temperature-humidity heat stress is estimated in farm animals by indices derived of an index based on human thermal comfort sensation. The latter index consists of temperature and humidity measures that sum to form the temperature-humidity index (THI). The hitherto unknown relative contribution of temperature and humidity to the THI was examined. A temperature-humidity data set (temperature 20-42 °C and relative humidity 10-70 %) was used to assess by regression procedures the relative weights of temperature and humidity in the variance of THI values produced by six commonly used heat stress indices. The temperature (Ta) effect was predominant (0.82-0.95 of variance) and humidity accounted for only 0.05 to 0.12 of THI variance, half of the variance encountered in animal responses to variable humidity heat stress. Significant difference in THI values was found between indices in the relative weights of temperature and humidity. As in THI indices, temperature and humidity are expressed in different physical units, their sum has no physical attributes, and empirical evaluations assess THI relation to animal responses. A sensible heat THI was created, in which at higher temperatures humidity reaches 0.25 of sensible heat, similarly to evaporative heat loss span in heat stressed animals. It relates to ambient temperature-humidity similarly to present THI; its values are similar to other THI but greater at higher humidity. In warm conditions, mean animal responses are similar in both indices. The higher sensitivity to humidity makes this index preferable for warm-humid conditions.
Lin, Cherng-Yuan; Chen, Wei-Cheng
2004-01-01
A marine furnace made of stainless steel. combined with an automatic small-size oil-fired burner, was used to experimentally investigate the influences of calcium oxide content in fuel oil on the combustion and emission characteristics under varying temperatures and humidity of the inlet air. Marine fuel oil generally contains various extents of metallic oxides such as CaO, Fe2O3, V2O5, etc which might affect its burning properties. In this study, an air-conditioner was used to adjust the humidity and temperatures of the inlet air to preset values prior to entering the burner. The adjusted inlet air atomized the marine diesel oil A containing a calcium oxide compound, to form a heterogeneous reactant mixture. The reactant mixture was thereafter ignited by a high-voltage electrode in the burner and burned within the marine furnace. The probes of a gas analyzer, H2S analyzer and a K-type thermocouple were inserted into the radial positions of the furnace through the eight rectangular slots which were cut in the upper side of the furnace. The experimental results showed that an increase of either humidity or temperature of the inlet air caused the promotion of the reaction rate of the fuel. The existence of calcium oxide compound in the diesel fuel also facilitated the oxidation reaction in the combustion chamber. The addition of CaO in the diesel fuel under the conditions of higher temperature or higher relative humidity of the inlet air produced the following: higher concentrations of CO2, SO2, and H2S emissions, an increased burning efficiency, a lowered O2 level, production of excess air and NOx emissions as well as a lower thermal loss and a lower burning gas temperature, as compared with the conditions of a lower temperature or a lower humidity of the inlet air. In addition, the burning of diesel fuel with added CaO compound caused a large variation in the burning efficiency, thermal loss, plus CO2, O2, and excess air emissions between the conditions of higher temperature/higher humidity and lower temperature/lower humidity inlet air compared with no CaO addition in the fuel. Moreover, the burning efficiency and the concentrations of excess air and O2 emissions increased, while the thermal loss, burning gas temperature and H2S, SO2, NOx, and CO2 emissions decreased with the increase of the axial distance from the measured location to the burner nozzle.
Mauger, Scott A.; Steirer, K. Xerxes; Boe, Jonas; ...
2016-01-19
Here, this work focuses on the role of humidity in the formation of ZnO thin films from a reactive diethylzinc precursor solution for use as the electron contact layer (ECL) in organic photovoltaic (OPV) devices. This method is well suited for flexible devices because the films are annealed at 120 °C, making the process compatible with polymer substrates. ZnO films were prepared by spin coating and annealing at different relative humidity (RH) levels. It is found that RH during coating and annealing affects the chemical and physical properties of the ZnO films. Using x-ray photoelectron spectroscopy it is found thatmore » increasing RH during the formation steps produces a more stoichiometric oxide and a higher Zn/O ratio. Spectroscopic ellipsometry data shows a small decrease in the optical band gap with increased humidity, consistent with a more stoichiometric oxide. Kelvin probe measurements show that increased RH during formation results in a larger work function (i.e. further from vacuum). Consistent with these data, but counter to what might be expected, when these ZnO films are used as ECLs in OPV devices those with ZnO ECLs processed in low RH (less stoichiometric) had higher power conversion efficiency than those with high-RH processed ZnO due to improved open-circuit voltage. The increase in open-circuit voltage with decreasing humidity was observed with two different donor polymers and fullerene acceptors, which shows the trend is due to changes in ZnO. The observed changes in open-circuit voltage follow the same trend as the ZnO work function indicating that the increase in open-circuit voltage with decreasing humidity is the result of improved energetics at the interface between the bulk-heterojunction and the ZnO layer due to a vacuum level shift.« less
Kalra, Bhawna; Parkash, Ravi
2016-10-15
Seasonally varying populations of ectothermic insect taxa from a given locality are expected to cope with simultaneous changes in temperature and humidity through phenotypic plasticity. Accordingly, we investigated the effect of saturation deficit on resistance to desiccation in wild-caught flies from four seasons (spring, summer, rainy and autumn) and corresponding flies reared in the laboratory under season-specific simulated temperature and humidity growth conditions. Flies raised under summer conditions showed approximately three times higher desiccation resistance and increased levels of cuticular lipids compared with flies raised in rainy season conditions. In contrast, intermediate trends were observed for water balance-related traits in flies reared under spring or autumn conditions but trait values overlapped across these two seasons. Furthermore, a threefold difference in saturation deficit (an index of evaporative water loss due to a combined thermal and humidity effect) between summer (27.5 mB) and rainy (8.5 mB) seasons was associated with twofold differences in the rate of water loss. Higher dehydration stress due to a high saturation deficit in summer is compensated by storage of higher levels of energy metabolite (trehalose) and cuticular lipids, and these traits correlated positively with desiccation resistance. In Z. indianus, the observed changes in desiccation-related traits due to plastic effects of simulated growth conditions correspond to similar changes exhibited by seasonal wild-caught flies. Our results show that developmental plastic effects under ecologically relevant thermal and humidity conditions can explain seasonal adaptations for water balance-related traits in Z. indianus and are likely to be associated with its invasive potential. © 2016. Published by The Company of Biologists Ltd.
Humidity-Induced Photoluminescence Hysteresis in Variable Cs/Br Ratio Hybrid Perovskites.
Howard, John M; Tennyson, Elizabeth M; Barik, Sabyasachi; Szostak, Rodrigo; Waks, Edo; Toney, Michael F; Nogueira, Ana F; Neves, Bernardo R A; Leite, Marina S
2018-06-21
Hybrid organic-inorganic perovskites containing Cs are a promising new material for light-absorbing and light-emitting optoelectronics. However, the impact of environmental conditions on their optical properties is not fully understood. Here, we elucidate and quantify the influence of distinct humidity levels on the charge carrier recombination in Cs x FA 1- x Pb(I y Br 1- y ) 3 perovskites. Using in situ environmental photoluminescence (PL), we temporally and spectrally resolve light emission within a loop of critical relative humidity (rH) levels. Our measurements show that exposure up to 35% rH increases the PL emission for all Cs (10-17%) and Br (17-38%) concentrations investigated here. Spectrally, samples with larger Br concentrations exhibit PL redshift at higher humidity levels, revealing water-driven halide segregation. The compositions considered present hysteresis in their PL intensity upon returning to a low-moisture environment due to partially reversible hydration of the perovskites. Our findings demonstrate that the Cs/Br ratio strongly influences both the spectral stability and extent of light emission hysteresis. We expect our method to become standard when testing the stability of emerging perovskites, including lead-free options, and to be combined with other parameters known for affecting material degradation, e.g., oxygen and temperature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2013-11-01
Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75 degrees F, the perceived air temperature can vary by 11 degrees F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers frommore » the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74 degrees -80 degrees F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.« less
Climatic factors associated with peripartum pig deaths during hot and humid or cold seasons.
Iida, Ryosuke; Koketsu, Yuzo
2014-08-01
Our objective was to quantify the associations between climatic factors and a death occurrence of peripartum pigs from 16 to 19 weeks after successful service during hot and humid or cold seasons. The study used lifetime records of 93,837 females entered into 98 Japanese commercial herds from 2003 to 2007. The climate data were obtained from 21 weather stations close to the studied herds. Average daily maximum (HT) and minimum temperature (LT), and relative humidity for week 15 of gestation for each pregnant pig were coordinated with the respective pig's performance data. Multilevel logistic regression models were applied to two of the three separate datasets. One dataset included females due to farrow during the hot and humid season (June-September), and another comprised females due to farrow during the cold season (December-March). Of the 8381 females that died throughout the year, 11.5% of pregnant pigs died between 16 and 17 weeks after service, and 44.3% of farrowed females subsequently died from 16 to 19 weeks after service. Mean (ranges) HT in the hot and humid season and LT in the cold season were 28.7 (13.4-39.8) °C and 1.6 (-14.8 to 17.6) °C, respectively. Means of relative humidity in the hot and humid season and cold season were 73.6 (35-98)% and 64.9 (21-99)%, respectively. In the hot and humid season, a higher HT was associated with a higher occurrence of death for parity 0-1 females (P<0.05), but not for parity 2 or higher sows (P≥0.38). The odds ratio was 1.030 (95% confidence intervals: 1.005-1.056) for HT in parity 0-1 females. Also, higher relative humidity was associated with a higher occurrence of death for parity 0-3 females (P<0.05), but not parity 4 or higher sows (P≥0.21). In the cold season, a higher occurrence of death of parity 4 or higher sows was associated with lower LT (P<0.05). Also, the occurrence of death of parity 6 or higher sows was associated with higher relative humidity in the cold season (P<0.05). For parity 0-3 females, there were no associations between the occurrences of death and either LT or relative humidity during the cold season (P≥0.11). Therefore, it is recommended to install cooling systems and thick insulation to prevent increases in occurrences of pig deaths due to HT or LT. Copyright © 2014 Elsevier B.V. All rights reserved.
Humidity-swing mechanism for CO2 capture from ambient air.
Yang, Hao; Singh, Manmilan; Schaefer, Jacob
2018-05-10
A humidity-swing polymeric sorbent captures CO2 from ambient air at room temperature simply by changing the humidity level. To date there has been no direct experimental evidence to characterize the chemical mechanism for this process. In this report we describe the use of solid-state NMR to study the humidity-swing CO2 absorption/desorption cycle directly. We find that at low humidity levels CO2 is absorbed as HCO3-. At high humidity levels, HCO3- is replaced by hydrated OH- and the absorbed CO2 is released.
Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.
Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia
2013-09-03
Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.
Duan, Wen-biao; Du, Shan; Chen, Li-xin; Wang, Li-xia; Wei, Quan-shuai; Zhao, Jian-hui
2013-08-01
Three representative forest gaps with pit-mound microsites formed by uprooted trees were selected within the 2.55 hm2 plot in a Pinus koraiensis-dominated broad-leaved mixed forest in Xiao Xing'an Mountains of Northeast China. The cleared land and closed stand were set up as the controls, and the PAR, air temperature and relative humidity in the centers of different size gaps and in mound top as well as the total radiation and precipitation in the gap centers were measured between July and September, 2011 by using multichannel automatic meteorological stations. The differences of the microclimate between the gap centers and mound top in different months were compared, and the monthly and diurnal variations of the microclimatic factors in the gap centers and in the mound top under typical weather conditions were analyzed. The results showed that the mean monthly PAR and air temperature in the three gaps of different sizes were in the order of large gap > medium gap > small gap, and the mean monthly relative humidity was in the order of small gap > medium gap > large gap. For the same size gap, the mean monthly PAR and air temperature were higher in the mound top than in the gap center, whereas the mean monthly relative humidity was higher in the gap center than in the mound top. Both the mean monthly total radiation and the mean monthly air temperature in the forest gaps and in the controls were in the order of July > August > September and of cleared land > large gap > medium gap > small gap > closed stand, while the mean monthly relative humidity was in the order of closed stand > small gap > medium gap > large gap > cleared land. The differences in the mean monthly relative humidity between closed stand and various gaps and between closed stand and cleared land reached significant level. The monthly precipitation from July to September decreased in the order of cleared land > large gap > medium gap > small gap > closed stand. Whether in sunny days or in overcast days, the mean daily PAR and air temperature were higher in mound top than in gap center, and the mean daily relative humidity was in opposite. Whether in mound top or in gap center, the mean daily PAR and air temperature were higher in sunny days than in overcast days, while the mean daily relative humidity was higher in overcast days than in sunny days.
Humidity sensation requires both mechanosensory and thermosensory pathways in Caenorhabditis elegans
Russell, Joshua; Vidal-Gadea, Andrés G.; Makay, Alex; Lanam, Carolyn; Pierce-Shimomura, Jonathan T.
2014-01-01
All terrestrial animals must find a proper level of moisture to ensure their health and survival. The cellular-molecular basis for sensing humidity is unknown in most animals, however. We used the model nematode Caenorhabditis elegans to uncover a mechanism for sensing humidity. We found that whereas C. elegans showed no obvious preference for humidity levels under standard culture conditions, worms displayed a strong preference after pairing starvation with different humidity levels, orienting to gradients as shallow as 0.03% relative humidity per millimeter. Cell-specific ablation and rescue experiments demonstrate that orientation to humidity in C. elegans requires the obligatory combination of distinct mechanosensitive and thermosensitive pathways. The mechanosensitive pathway requires a conserved DEG/ENaC/ASIC mechanoreceptor complex in the FLP neuron pair. Because humidity levels influence the hydration of the worm’s cuticle, our results suggest that FLP may convey humidity information by reporting the degree that subcuticular dendritic sensory branches of FLP neurons are stretched by hydration. The thermosensitive pathway requires cGMP-gated channels in the AFD neuron pair. Because humidity levels affect evaporative cooling, AFD may convey humidity information by reporting thermal flux. Thus, humidity sensation arises as a metamodality in C. elegans that requires the integration of parallel mechanosensory and thermosensory pathways. This hygrosensation strategy, first proposed by Thunberg more than 100 y ago, may be conserved because the underlying pathways have cellular and molecular equivalents across a wide range of species, including insects and humans. PMID:24843133
Effects of street canyon design on pedestrian thermal comfort in the hot-humid area of China.
Zhang, Yufeng; Du, Xiaohan; Shi, Yurong
2017-08-01
The design characteristics of street canyons were investigated in Guangzhou in the hot-humid area of China, and the effects of the design factors and their interactions on pedestrian thermal comfort were studied by numerical simulations. The ENVI-met V4.0 (BASIC) model was validated by field observations and used to simulate the micrometeorological conditions and the standard effective temperature (SET) at pedestrian level of the street canyons for a typical summer day of Guangzhou. The results show that the micrometeorological parameters of mean radiant temperature (MRT) and wind speed play key roles in pedestrian thermal comfort. Street orientation has the largest contribution on SET at pedestrian level, followed by aspect ratio and greenery, while surface albedo and interactions between factors have small contributions. The street canyons oriented southeast-northwest or with a higher aspect ratio provide more shade, higher wind speed, and better thermal comfort conditions for pedestrians. Compared with the east-west-oriented street canyons, the north-south-oriented street canyons have higher MRTs and worse pedestrian thermal comfort due to their wider building spacing along the street. The effects of greenery change with the road width and the time of the day. Street canyon design is recommended to improve pedestrian thermal comfort. This study provides a better understanding of the effects of street canyon design on pedestrian thermal comfort and is a useful guide on urban design for the hot-humid area of China.
Pan, Hongsheng; Liu, Bing; Lu, Yanhui; Desneux, Nicolas
2014-01-01
The genus Adelphocoris (Hemiptera: Miridae) is a group of important insect pests of Bt cotton in China. The three dominant species are A. lineolatus, A. suturalis, and A. fasciaticollis, and these species have different population dynamics. The causal factors for the differences in population dynamics have not been determined; one hypothesis is that humidity may be important for the growth of Adelphocoris populations. In the laboratory, the demographic parameters of the three Adelphocoris species were compared when the mirid bugs were subjected to various levels of relative humidity (40, 50, 60, 70 and 80% RH). Middle to high levels of RH (60, 70 and 80%) were associated with higher egg and nymph survival rates and increased adult longevity and female fecundity. Lower humidity levels (40 and 50% RH) had negative effects on the survival of nymphs, adult longevity and fecundity. The intrinsic rate of increase (rm), the net reproductive rate (R0) and the finite rate of increase (λ) for each Adelphocoris species increased with increasing RH. Significant positive relationships were found between RH and the life table parameters, rm, R0 and λ for the three Adelphocoris species. These results will help to better understand the phenology of the three Adelphocoris species, and the information can be used in population growth models to optimize pest forecasting and management strategies for these key pests.
Pan, Hongsheng; Liu, Bing; Lu, Yanhui; Desneux, Nicolas
2014-01-01
The genus Adelphocoris (Hemiptera: Miridae) is a group of important insect pests of Bt cotton in China. The three dominant species are A. lineolatus, A. suturalis, and A. fasciaticollis, and these species have different population dynamics. The causal factors for the differences in population dynamics have not been determined; one hypothesis is that humidity may be important for the growth of Adelphocoris populations. In the laboratory, the demographic parameters of the three Adelphocoris species were compared when the mirid bugs were subjected to various levels of relative humidity (40, 50, 60, 70 and 80% RH). Middle to high levels of RH (60, 70 and 80%) were associated with higher egg and nymph survival rates and increased adult longevity and female fecundity. Lower humidity levels (40 and 50% RH) had negative effects on the survival of nymphs, adult longevity and fecundity. The intrinsic rate of increase (rm), the net reproductive rate (R0) and the finite rate of increase (λ) for each Adelphocoris species increased with increasing RH. Significant positive relationships were found between RH and the life table parameters, rm, R0 and λ for the three Adelphocoris species. These results will help to better understand the phenology of the three Adelphocoris species, and the information can be used in population growth models to optimize pest forecasting and management strategies for these key pests. PMID:25541705
Su, Qin; Liu, Hongsheng; Yuan, Xiaoling; Xiao, Yan; Zhang, Xian; Sun, Rongju; Dang, Wei; Zhang, Jianbo; Qin, Yuhong; Men, Baozhong; Zhao, Xiaodong
2014-11-01
Few epidemiological studies have been reported as to whether there was any interactive effect between temperature and humidity on respiratory morbidity, especially in Asian countries. The present study used time-series analysis to explore the modification effects of humidity on the association between temperature and emergency room (ER) visits for respiratory, upper respiratory tract infection (URI), pneumonia, and bronchitis in Beijing between 2009 and 2011. Results showed that an obvious joint effect of temperature and humidity was revealed on ER visits for respiratory, URI, pneumonia, and bronchitis. Below temperature threshold, the temperature effect was stronger in low humidity level and presented a trend fall with humidity level increase. The effect estimates per 1 °C increase in temperature in low humidity level were -2.88 % (95 % confidence interval (CI) -3.08, -2.67) for all respiratory, -3.24 % (-3.59, -2.88) for URI, -1.48 % (-1.93, -1.03) for pneumonia, and -3.79 % (-4.37, -3.21) for bronchitis ER visits, respectively. However, above temperature threshold, temperature effect was greater in high humidity level and trending upward with humidity level increasing. In high humidity level, a 1 °C increase in temperature, the effect estimates were 1.84 % (1.55, 2.13) for all respiratory, 1.76 % (1.41, 2.11) for URI, and 7.48 % (4.41, 10.65) for bronchitis ER visits. But, there was no statistically significant for pneumonia. This suggests that the modifying effects of the humidity should be considered when analyzing health impacts of temperature.
NASA Astrophysics Data System (ADS)
Verdingovas, Vadimas; Jellesen, Morten Stendahl; Ambat, Rajan
2015-04-01
This paper presents the results of humidity testing of weak organic acids (WOAs), namely adipic, succinic, glutaric, dl-malic, and palmitic acids, which are commonly used as activators in no-clean solder fluxes. The study was performed under humidity conditions varying from 60% relative humidity (RH) to ˜99%RH at 25°C. The following parameters were used for characterization of WOAs: mass gain due to water adsorption and deliquescence of the WOA (by quartz crystal microbalance), resistivity of the water layer formed on the printed circuit board (by impedance spectroscopy), and leakage current measured using the surface insulation resistance pattern in the potential range from 0 V to 10 V. The combined results indicate the importance of the WOA chemical structure for the water adsorption and therefore conductive water layer formation on the printed circuit board assembly (PCBA). A substantial increase of leakage currents and probability of electrochemical migration was observed at humidity levels above the RH corresponding to the deliquescence point of WOAs present as contaminants on the printed circuit boards. The results suggest that use of solder fluxes with WOAs having higher deliquescence point could improve the reliability of electronics operating under circumstances in which exposure to high humidity is likely to occur.
Jo, Eun-Jung; Lee, Woo-Seop; Jo, Hyun-Young; Kim, Chang-Hoon; Eom, Jung-Seop; Mok, Jeong-Ha; Kim, Mi-Hyun; Lee, Kwangha; Kim, Ki-Uk; Lee, Min-Ki; Park, Hye-Kyung
2017-03-01
Both air pollution and weather impact hospitalization for respiratory diseases. However, few studies have investigated the contribution of weather to hospitalization related to the adverse effects of air pollution. This study analyzed the effects of particulate matter (PM) on daily respiratory-related hospital admissions, taking into account meteorological factors. Daily hospital admissions for respiratory diseases (acute bronchitis, allergic rhinitis, and asthma) between 2007 and 2010 were extracted from the National Health Insurance Corporation, Korea. Patients were divided into three age-based groups (0-15, 16-64, and ≥65 years). PM levels were obtained from 19 monitoring stations in Busan. The mean number of patients admitted for acute bronchitis, allergic rhinitis, and asthma was 5.8 ± 11.9, 4.4 ± 6.1, and 3.3 ± 3.3, respectively. During that time, the daily mean PM 10 and PM 2.5 concentrations were 49.6 ± 20.5 and 24.2 ± 10.9 μg/m 3 , respectively. The mean temperature anomaly was 7.0 ± 2.3 °C; the relative humidity was 62.0 ± 18.0%. Hospital admission rates for respiratory diseases increased with increasing PM and temperature, and with decreasing relative humidity. A multivariate analysis including PM, temperature anomaly, relative humidity, and age showed a significant increase in respiratory-related admissions with increasing PM levels and a decreasing relative humidity. Higher PM 2.5 levels had a greater effect on respiratory-related hospital admission than did PM 10 levels. Children and the elderly were the most susceptible to hospital admission for respiratory disease. PM levels and meteorological factors impacted hospitalization for respiratory diseases, especially in children and the elderly. The effect of PM on respiratory diseases increased as the relative humidity decreased. Copyright © 2017 Elsevier Ltd. All rights reserved.
Parkash, Ravi; Ranga, Poonam
2014-03-01
Drosophila leontia is native to highly humid equatorial tropical habitats but its desiccation sensitivity (~10h) is not consistent with its abundance during the drier autumn season in the subtropical regions. We have tested the effects of developmental acclimation on desiccation resistance and water balance related traits of D. leontia collected during rainy and autumn seasons. The isofemale lines of seasonal populations were reared under ecologically relevant growth temperatures (18 or 26 °C) or humidity conditions (35 or 85% RH) but tested at different times under identical experimental conditions. The larvae as well as flies reared under two thermal conditions (18 or 26 °C) showed no effect on desiccation related traits as well as storage and utilization of energy metabolites. In contrast, for D. leontia reared under low humidity (35% RH), significant changes at larval as well adult stages include increase in the desiccation resistance as well as cuticular lipid quantity, reduced levels of rate of body water loss, higher storage of carbohydrates but lower rate of utilization of carbohydrates as compared with flies reared at high humidity (85% RH). D. leontia has responded to rearing under low humidity conditions by increasing its desiccation resistance but not due to changes in the growth temperatures. These laboratory observations on seasonal populations highlight differences due to rearing conditions but not due to seasons. Further, direct analysis of wild-caught seasonal populations has shown trends similar to developmental acclimation effects. For wild caught flies, there are significant seasonal differences i.e. higher desiccation resistance as well as cuticular lipid quantity but reduced rate of water loss for autumn than rainy season flies. Thus, our laboratory observations are relevant for understanding seasonal adaptations of natural populations of tropical D. leontia to wet-dry conditions in the wild. Copyright © 2013 Elsevier Inc. All rights reserved.
Short term change in relative humidity during the festival of Diwali in India
NASA Astrophysics Data System (ADS)
Ganguly, Nandita D.
2015-07-01
The changes in humidity levels during the Diwali festivities have been examined over a period of 13 years at three Indian metro cities: Ahmedabad, New Delhi and Kolkata. A small short term increase in relative humidity even in the absence of transport of humid air from Arabian Sea and Bay of Bengal has been observed. The relative humidity levels were found to be exceeding the ambient levels during night and lying below the ambient levels during morning hours, indicating an increase in the survival rates of viruses responsible for the transmission of viral infections, as well as triggering immune-mediated illnesses such as asthma during Diwali.
Xu, Jing; Zhang, Jianshun S; Liu, Xiaoyu; Gao, Zhi
2012-06-01
The partition and effective diffusion coefficients of formaldehyde were measured for three materials (conventional gypsum wallboard, "green" gypsum wallboard, and "green" carpet) under three relative humidity (RH) conditions (20%, 50%, and 70% RH). The "green" materials contained recycled materials and were friendly to environment. A dynamic dual-chamber test method was used. Results showed that a higher relative humidity led to a larger effective diffusion coefficient for two kinds of wallboards and carpet. The carpet was also found to be very permeable resulting in an effective diffusion coefficient at the same order of magnitude with the formaldehyde diffusion coefficient in air. The partition coefficient (K(ma)) of formaldehyde in conventional wallboard was 1.52 times larger at 50% RH than at 20% RH, whereas it decreased slightly from 50% to 70% RH, presumably due to the combined effects of water solubility of formaldehyde and micro-pore blocking by condensed moisture at the high RH level. The partition coefficient of formaldehyde increased slightly with the increase of relative humidity in "green" wallboard and "green" carpet. At the same relative humidity level, the "green" wallboard had larger partition coefficient and effective diffusion coefficient than the conventional wallboard, presumably due to the micro-pore structure differences between the two materials. The data generated could be used to assess the sorption effects of formaldehyde on building materials and to evaluate its impact on the formaldehyde concentration in buildings.
Extending the potential of evaporative cooling for heat-stress relief.
Berman, A
2006-10-01
Factors were analyzed that limit the range of environmental conditions in which stress from heat may be relieved by evaporative cooling in shaded animals. Evaporative cooling reduces air temperature (Ta), but increases humidity. Equations were developed to predict Ta reduction as a function of ambient temperature and humidity and of humidity in cooled air. Predictions indicated that a reduction of Ta becomes marginal at humidities beyond 45%. A reduction of Ta lessens with rising ambient Ta. The impact of increasing humidity on respiratory heat loss (Hre) was estimated from existing data published on Holstein cattle. Respiratory heat loss is reduced by increased humidity up to 45%, but is not affected by higher humidity. Skin evaporative and sensible heat losses are determined not only by the humidity and temperature gradient, but also by air velocity close to the body surface. At higher Ta, the reduction in sensible heat loss is compensated for by an increased demand for Hre. High Hre may become a stressor when panting interferes with resting and rumination. Effects of temperature, humidity, air velocity, and body surface exposure to free air on Hre were estimated by a thermal balance model for lactating Holstein cows yielding 35 kg/d. The predictions of the simulations were supported by respiratory rate observations. The Hre was assumed to act as a stressor when exceeding 50% of the maximal capacity. When the full body surface was exposed to a 1.5 m/s air velocity, humidity (15 to 75%) had no significant predicted effect on Hre. For an air velocity of 0.3 m/s, Hre at 50% of the maximum rate was predicted at 34, 32.5, and 31.5 degrees C for relative humidities of 55, 65, and 75%, respectively. Similar results were predicted for an animal with two-thirds of its body surface exposed to 1.5 m/s air velocity. If air velocity was reduced for such animals to 0.3 m/s, the rise in Hre was expected to occur at approximately 25 degrees C and 50% relative humidity. Maximal rates of Hre were estimated at 27 to 30 degrees C when ambient humidity was 55% relative humidity and higher. High humidity may stress animals in evaporative cooling systems. Humidity stress may be prevented by a higher air velocity on the body surface of the animal, particularly in sheltered areas in which the exposed body surface is reduced, such as mangers and stalls. This may extend the use of evaporative cooling to less dry environments.
Cariou, Stephane; Guillot, Jean-Michel
2006-01-01
Tedlar bags, which are widely used to collect air samples, especially VOCs and odorous atmospheres, can allow humidity to diffuse when relative humidity levels differ between the inside and outside. Starting with dry air inside the bag and humid air outside, we monitored equilibrium times under several conditions showing the evolution and influence of collected volumes and exposed surfaces. A double-film Tedlar bag was made, to limit the impact of external humidity on a sample at low humidity level. With the addition of a drying agent between both films, the evolution of humidity of a sample can be stopped for several hours. When a VOC mixture was monitored in a humid atmosphere, humidity was decreased but no significant evolution of VOC concentrations was observed.
NASA Astrophysics Data System (ADS)
Buchholz, Bernhard; Ebert, Volker
2018-01-01
Highly accurate water vapor measurements are indispensable for understanding a variety of scientific questions as well as industrial processes. While in metrology water vapor concentrations can be defined, generated, and measured with relative uncertainties in the single percentage range, field-deployable airborne instruments deviate even under quasistatic laboratory conditions up to 10-20 %. The novel SEALDH-II hygrometer, a calibration-free, tuneable diode laser spectrometer, bridges this gap by implementing a new holistic concept to achieve higher accuracy levels in the field. We present in this paper the absolute validation of SEALDH-II at a traceable humidity generator during 23 days of permanent operation at 15 different H2O mole fraction levels between 5 and 1200 ppmv. At each mole fraction level, we studied the pressure dependence at six different gas pressures between 65 and 950 hPa. Further, we describe the setup for this metrological validation, the challenges to overcome when assessing water vapor measurements on a high accuracy level, and the comparison results. With this validation, SEALDH-II is the first airborne, metrologically validated humidity transfer standard which links several scientific airborne and laboratory measurement campaigns to the international metrological water vapor scale.
Wikner, I; Gebresenbet, G; Nilsson, C
2003-03-01
Transport by road can induce significant stress in cattle. Thermal stress is among the main stress producing factors during transport. The provision of ventilation in livestock transport vehicles is usually through openings along the sides of the vehicle. The incoming air will affect air quality inside by regulating temperature, relative humidity, gas levels and levels of other contaminants. The aim of the present investigation was to map out the air quality in a commercial cattle transport vehicle under various climatic conditions and with varying stocking densities and transport times. Distributions of air temperature, relative humidity and concentrations of ammonia, carbon dioxide, oxygen and methane have been determined during 35 experimental journeys. In average the mean temperature inside the compartment was about 3 degrees C and 6 degrees C higher than outside temperature in summer (+7.8(-)+24.0 degrees C) and winter (-24.3(-)+12.7 degrees C) conditions respectively. The temperature increment inside, as could be expected from theory, increased with reduced ventilation and increased animal density. Many stops to load new animals lowered the temperature increment and relative humidity in winter time. In summer more stops made the compartment temperature and relative humidity increase. The inside temperature distribution was less than about 3 degrees C during both summer and winter season. Average ammonia level varied between 3 and 6 ppm depending on stocking density and number of stops with a maximum value of 18 ppm. No detectable methane levels could be found inside the compartment at any time.
Williams, R; Rankin, N; Smith, T; Galler, D; Seakins, P
1996-11-01
To review the available literature on the relationship between the humidity and temperature of inspired gas and airway mucosal function. International computerized databases and published indices, experts in the field, conference proceedings, bibliographies. Two hundred articles/texts on respiratory tract physiology and humidification were reviewed. Seventeen articles were selected from 40 articles for inclusion in the published data verification of the model. Selection was by independent reviewers. Extraction was by consensus, and was based on finding sufficient data. A relationship exists between inspired gas humidity and temperature, exposure time to a given humidity level, and mucosal function. This relationship can be modeled and represented as an inspired humidity magnitude vs. exposure time map. The model is predictive of mucosal function and can be partially verified by the available literature. It predicts that if inspired humidity deviates from an optimal level, a progressive mucosal dysfunction begins. The greater the humidity deviation, the faster the mucosal dysfunction progresses. A model for the relationship between airway mucosal dysfunction and the combination of the humidity of inspired gas and the duration over which the airway mucosa is exposed to that humidity is proposed. This model suggests that there is an optimal temperature and humidity above which, and below which, there is impaired mucosal function. This optimal level of temperature and humidity is core temperature and 100% relative humidity. However, existing data are only sufficient to test this model for gas conditions below core temperature and 100% relative humidity. These data concur with the model in that region. No studies have yet looked at this relationship beyond 24 hrs. Longer exposure times to any given level of inspired humidity and inspired gas temperatures and humidities above core temperature and 100% relative humidity need to be studied to fully verify the proposed model.
Cheng, Qiang; Bai, Lijun; Zhang, Yanwu; Zhang, Heng; Wang, Shusi; Xie, Mingyu; Zhao, Desheng; Su, Hong
2018-06-01
The relationship between ambient temperature, humidity and hand, foot, and mouth disease (HFMD) has been highlighted in East and Southeast Asia, which showed multiple different results. Therefore, our goal is to conduct a meta-analysis to further clarify this relationship and to quantify the size of these effects as well as the susceptible populations. PubMed, Web of science, and Cochrane library were searched up to November 22, 2017 for articles analyzing the relationships between ambient temperature, humidity and incidence of HFMD. We assessed sources of heterogeneity by study design (temperature measure and exposed time resolution), population vulnerability (national income level and regional climate) and evaluated pooled effect estimates for the subgroups identified in the heterogeneity analysis. We identified 11 studies with 19 estimates of the relationship between ambient temperature, humidity and incidence of HFMD. It was found that per 1°C increase in the temperature and per 1% increase in the relative humidity were both significantly associated with increased incidence of HFMD (temperature: IRR, 1.05; 95% CI, 1.02-1.08; relative humidity: IRR, 1.01; 95% CI, 1.00-1.02). Subgroup analysis showed that people living in subtropical and middle income areas had a higher risk of incidence of HFMD. Ambient temperature and humidity may increase the incidence of HFMD in Asia-Pacific regions. Further studies are needed to clarify the relationship between ambient temperature, humidity and incidence of HFMD in various settings with distinct climate, socioeconomic, and demographic features. Copyright © 2018. Published by Elsevier B.V.
High-coercivity minerals from North African Humid Period soil material deposited in Lake Yoa (Chad)
NASA Astrophysics Data System (ADS)
Just, J.; Kroepelin, S.; Wennrich, V.; Viehberg, F. A.; Wagner, B.; Rethemeyer, J.; Karls, J.; Melles, M.
2015-12-01
The Holocene is a period of fundamental climatic change in North Africa. Humid conditions during the so-called African Humid Period (AHP) have favored the formation of big lake systems. Only very few of these lakes persist until today. One of them is Lake Yoa (19°03'N/20°31'E) in the Ounianga Basin, Chad, which maintains its water level by ground water inflow. Here we present the magnetic characteristics together with proxies for lacustrine productivity and biota of a sediment core (Co1240) from Lake Yoa, retrieved in 2010 within the framework of the Collaborative Research Centre 806 - Our Way to Europe (Deutsche Forschungsgemeinschaft). Magnetic properties of AHP sediments show strong indications for reductive diagenesis. An up to ~ 80 m higher lake level is documented by lacustrine deposits in the Ounianga Basin, dating to the early phase of the AHP. The higher lake level and less strong seasonality restricted deep mixing of the lake. Development of anoxic conditions consequently lead to the dissolution of iron oxides. An exception is an interval with high concentration of high-coercivity magnetic minerals, deposited between 7800 - 8120 cal yr BP. This interval post-dates the 8.2 event, which was dry in Northern Africa and probably caused a reduced vegetation cover. We propose that the latter resulted in the destabilization of soils around Lake Yoa. After the re-establishment of humid conditions, these soil materials were eroded and deposited in the lake. Magnetic minerals appear well preserved in the varved Late Holocene sequence, indicating (sub-) oxic conditions in the lake. This is surprising, because the occurrence of varves is often interpreted as an indicator for anoxic conditions of the lake water. However, the salinity of lake water rose strongly after the AHP. We therefore hypothesize that the conservation of varves and absence of benthic organisms rather relates to the high salinity than to anoxic conditions.
Effect of high altitude on blood glucose meter performance.
Fink, Kenneth S; Christensen, Dale B; Ellsworth, Allan
2002-01-01
Participation in high-altitude wilderness activities may expose persons to extreme environmental conditions, and for those with diabetes mellitus, euglycemia is important to ensure safe travel. We conducted a field assessment of the precision and accuracy of seven commonly used blood glucose meters while mountaineering on Mount Rainier, located in Washington State (elevation 14,410 ft). At various elevations each climber-subject used the randomly assigned device to measure the glucose level of capillary blood and three different concentrations of standardized control solutions, and a venous sample was also collected for later glucose analysis. Ordinary least squares regression was used to assess the effect of elevation and of other environmental potential covariates on the precision and accuracy of blood glucose meters. Elevation affects glucometer precision (p = 0.08), but becomes less significant (p = 0.21) when adjusted for temperature and relative humidity. The overall effect of elevation was to underestimate glucose levels by approximately 1-2% (unadjusted) for each 1,000 ft gain in elevation. Blood glucose meter accuracy was affected by elevation (p = 0.03), temperature (p < 0.01), and relative humidity (p = 0.04) after adjustment for the other variables. The interaction between elevation and relative humidity had a meaningful but not statistically significant effect on accuracy (p = 0.07). Thus, elevation, temperature, and relative humidity affect blood glucose meter performance, and elevated glucose levels are more greatly underestimated at higher elevations. Further research will help to identify which blood glucose meters are best suited for specific environments.
Does the increased air humidity affect soil respiration and carbon stocks?
NASA Astrophysics Data System (ADS)
Kukumägi, Mai; Celi, Luisella; Said-Pullicino, Daniel; Kupper, Priit; Sõber, Jaak; Lõhmus, Krista; Kutti, Sander; Ostonen, Ivika
2013-04-01
Climate manipulation experiments at ecosystem-scale enable us to simulate, investigate and predict changes in carbon balance of forest ecosystems. Considering the predicted increase in air humidity and precipitation for northern latitudes, this work aimed at investigating the effect of increased air humidity on soil respiration, distribution of soil organic matter (SOM) among pools having different turnover times, and microbial, fine root and rhizome biomass. The study was carried out in silver birch (Betula pendula Roth.) and hybrid aspen (Populus tremula L. × P. tremuloides Michx.) stands in a Free Air Humidity Manipulation (FAHM) experimental facility containing three humidified (H; on average 7% above current ambient levels since 2008) and three control (C) plots. Soil respiration rates were measured monthly during the growing season using a closed dynamic chamber method. Density fractionation was adopted to separate SOM into two light fractions (free and aggregate-occluded particulate organic matter, fPOM and oPOM respectively), and one heavy fraction (mineral-associated organic matter, MOM). The fine root and rhizome biomass and microbial data are presented for silver birch stands only. In 2011, after 4 growing seasons of humidity manipulation soil organic carbon contents were significantly higher in C plots than H plot (13.5 and 12.5 g C kg-1, respectively), while soil respiration tended to be higher in the latter. Microbial biomass and basal respiration were 13 and 14% higher in H plots than in the C plots, respectively. Twice more fine roots of trees were estimated in H plots, while the total fine root and rhizome biomass (tree + understory) was similar in C and H plots. Fine root turnover was higher for both silver birch and understory roots in H plots. Labile SOM light fractions (fPOM and oPOM) were significantly smaller in H plots with respect to C plots (silver birch and hybrid aspen stands together), whereas no differences were observed in the contents of the more stable MOM. These results strongly suggest that, apart from the predicted increase in temperature and atmospheric carbon and nitrogen concentrations, an increase in free air humidity as a result of climate change may significantly influence the complex belowground carbon cycling by affecting biomass production, soil respiration and organic matter turnover.
NASA Technical Reports Server (NTRS)
Skorobatckyi, M.; Cosgrove, D. V.; Meng, P. R.; Kempe, E. E., Jr.
1978-01-01
A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions include carburetor lean out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity.
NASA Technical Reports Server (NTRS)
Skorobatckyi, M.; Cosgrove, D. V.; Meng, P. R.; Kempke, E. R.
1976-01-01
A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions included carburetor lean-out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel-air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity. Volume II contains the data taken at each of the individual test points.
Huang, Wan-Hua; Sui, Yue; Yang, Xiao-Guang; Dai, Shu-Wei; Li, Mao-Song
2013-10-01
Zoning seasonal drought based on the study of drought characteristics can provide theoretical basis for formulating drought mitigation plans and improving disaster reduction technologies in different arid zones under global climate change. Based on the National standard of meteorological drought indices and agricultural drought indices and the 1959-2008 meteorological data from 268 meteorological stations in southern China, this paper analyzed the climatic background and distribution characteristics of seasonal drought in southern China, and made a three-level division of seasonal drought in this region by the methods of combining comprehensive factors and main factors, stepwise screening indices, comprehensive disaster analysis, and clustering analysis. The first-level division was with the annual aridity index and seasonal aridity index as the main indices and with the precipitation during entire year and main crop growing season as the auxiliary indices, dividing the southern China into four primary zones, including semi-arid zone, sub-humid zone, humid zone, and super-humid zone. On this basis, the four primary zones were subdivided into nine second-level zones, including one semi-arid area-temperate-cold semi-arid hilly area in Sichuan-Yunnan Plateau, three sub-humid areas of warm sub-humid area in the north of the Yangtze River, warm-tropical sub-humid area in South China, and temperate-cold sub-humid plateau area in Southwest China, three humid areas of temperate-tropical humid area in the Yangtze River Basin, warm-tropical humid area in South China, and warm humid hilly area in Southwest China, and two super-humid areas of warm-tropical super-humid area in South China and temperate-cold super-humid hilly area in the south of the Yangtze River and Southwest China. According to the frequency and intensity of multiple drought indices, the second-level zones were further divided into 29 third-level zones. The distribution of each seasonal drought zone was illustrated, and the zonal drought characteristics and their impacts on the agricultural production were assessed. Accordingly, the drought prevention measures were proposed.
NASA Astrophysics Data System (ADS)
Rohmah, Nihayatur
2016-11-01
Islamic prayer times are based on the astronomical position of the Sun in the sky. One of them is the Fajr prayer. It is marked by some indicators in the morning twilight which is white light spread in the Eastern horizon. However, determining the true time of twilight can be difficult. One of the reasons is the effect of atmospheric humidity to the appearance of morning twilight. The higher the humidity, the redder twilight sky appearance. This paper discusses this effect. It is shown that despite of the same Sun's position, sky color can vary considerably. Observations of various solar dip angle have been made to study this effect. Visibility for different angle can change accordingly. We obtained that the average solar dip for Fajr prayer by morning twilight images was -18°39'29.4".
Can Nor'wester events initiate stratospheric moistening?
NASA Astrophysics Data System (ADS)
Ganguly, Nandita D.; Chakraborty, Rohit; Maitra, Animesh
2017-11-01
The possibility of stratospheric moistening being initiated by deep convective Nor'wester events has been investigated over a period of three years spanning from 2013 to 2015 at a tropical location Kolkata, in India using radiosonde and satellite data. The back trajectories, instability indices, outgoing long wave radiation (OLR), convective available potential energy (CAPE), geopotential height maps, vertical pressure velocity, specific humidity, wind vectors and precipitable water vapour (PWV) have been examined to assess the convective activity prevailing over the atmosphere during these events. Increase in specific humidity, wind velocity at various levels of the lower atmosphere and CAPE values indicate an upwelling of moist air from the troposphere to lower stratosphere during Nor'westers. Decrease in OLR and large differences in the values of instability indices, relative humidity and precipitable water vapour during Nor'westers compared to normal convection also signify high intensity of convection and hence the possibility of higher stratospheric moistening during Nor'wester events.
Inspired gas humidity and temperature during mechanical ventilation with the Stephanie ventilator.
Preo, Bianca L; Shadbolt, Bruce; Todd, David A
2013-11-01
To measure inspired gas humidity and temperature delivered by a Stephanie neonatal ventilator with variations in (i) circuit length; (ii) circuit insulation; (iii) proximal airway temperature probe (pATP) position; (iv) inspiratory temperature (offset); and (v) incubator temperatures. Using the Stephanie neonatal ventilator, inspired gas humidity and temperature were measured during mechanical ventilation at the distal inspiratory limb and 3 cm down the endotracheal tube. Measurements were made with a long or short circuit; with or without insulation of the inspiratory limb; proximal ATP (pATP) either within or external to the incubator; at two different inspiratory temperature (offset) of 37(-0.5) and 39(-2.0)°C; and at three different incubator temperatures of 32, 34.5, and 37°C. Long circuits produced significantly higher inspired humidity than short circuits at all incubator settings, while only at 32°C was the inspired temperature higher. In the long circuits, insulation further improved the inspired humidity especially at 39(-2.0)°C, while only at incubator temperatures of 32 and 37°C did insulation significantly improve inspired temperature. Positioning the pATP outside the incubator did not result in higher inspired humidity but did significantly improve inspired temperature. An inspiratory temperature (offset) of 39(-2.0)°C delivered significantly higher inspired humidity and temperature than the 37(-0.5)°C especially when insulated. Long insulated Stephanie circuits should be used for neonatal ventilation when the infant is nursed in an incubator. The recommended inspiratory temperature (offset) of 37(-0.5)°C produced inspired humidity and temperature below international standards, and we suggest an increase to 39(-2.0)°C. © 2013 John Wiley & Sons Ltd.
Ma, Xiaoqiang; Tan, Changheng; Zhu, Dayuan; Gang, David R
2005-03-09
A precise and selective reversed phase high-performance liquid chromatographic method was developed for quantifying huperzine A (HupA) in samples of the Huperziaceae in China. This method was used to quantify the levels of HupA in samples of Huperzia serrata collected from a single population at different times of the year, in different organs of the same H. serrata plant, and from different geographical locations of H. serrata plants in China. For different species of Huperziaceae, the highest content of HupA was found in Phlegmariurus carinatus. Members of the genus Phlegmariurus possessed higher levels of HupA than Huperzia species. H. serrata plants growing in humid forests contained significantly more HupA than plants growing in less humid environments. Finally, HupA content varied significantly by season, with the highest levels being found in mid fall and the lowest levels in early spring, suggesting that HupA is turned over in the plant.
Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings
NASA Astrophysics Data System (ADS)
Kraus, Michal
2017-10-01
Recent studies show that the relative humidity and the indoor air temperature constitute an important determinant of the quality of indoor air. Hygrothermal microclimate has a significant impact on occupant’s health and their comfort. The study presents the results of experimental measurement of indoor air temperature and relative humidity in selected apartment in prefabricated panel house situated in Ostrava, Czechia. The contribution describes and analysis the relation between indoor air temperature [°C] and relative humidity [%] in this apartment. The experimental object is selected with respect to the housing stock in the Czech Republic. A third of the housing stock in the Czech Republic is composed of prefabricated panel houses. Regeneration and revitalization of these buildings were in the focus of interest during recent years. Building modifications, such as thermal insulation of building envelope or window replacement, lead to a significantly higher level of airtightness of these objects. Humidity and indoor air temperature are measured in 10-minute cycles for two periods. The values of temperature and humidity are measured for the non-heating and the heating season. The length of each experimental period is 30 days. The mean value of indoor air temperature is 22.21 °C and average relative humidity is 45.87% in the non-heating period. The values of 22.62 °C and 35.20% represent average values for the heating period. A slight increase of the average temperature of the indoor environment (+1.85%) is observed. The decrease of the relative humidity is evident at first glance. The relative humidity of the internal environment is approximately 10% lower in the heating period. Long-term decline of relative humidity below 30% brings many problems. It is necessary to take measures to increase of relative humidity in residential prefabricated building. The aquarium appears to be ineffective. The solution may be forced artificial ventilation or humidifiers.
Saad-Hussein, A; Taha, M M; Fadl, N N; Awad, A-H; Mahdy-Abdallah, H; Moubarz, G; Aziz, H; El-Shamy, K A
2016-01-01
The present work aimed to investigate the relationship between occupational exposure to airborne molds, serum aflatoxin B1 (AFB1), and liver enzymes of workers handling wheat flour. The study included 90 bakers, 100 flour milling workers, and 100 controls with no exposure to flour dust. Workplace aspects such as temperature and relative humidity were measured. Airborne fungi were collected and identified. In all subjects included, the serum levels of AFB1, serum albumin (Alb), aspartate aminotransferase (AST), alanine aminotransferase (ALT), and alkaline phosphatase (ALP) were measured. Air temperature and relative humidity were found to be higher in bakeries than in flour mill sections. Airborne Aspergillus species were isolated in dust particles <8 µm in size. The concentration of Aspergillus flavus and Aspergillus niger were higher in bakeries than in the flour mill sections. They were higher in the grinding section than in other mill sections. The serum AFB1-Alb adduct and ALP levels were significantly higher in bakers compared to milling workers (p < 0.0001, p = 0.05), respectively. The liver enzymes AST and ALT were significantly higher among milling workers and bakers than controls (p < 0.05, p < 0.0001), respectively. The duration of exposure was significantly correlated with serum AFB1 in bakers. Moreover, there was significant correlation between serum AFB1, each of ALT and AST levels in bakers. chronic occupational exposure to high concentrations of Aspergillus in workplaces may cause elevations in serum levels of AFB1 and liver enzymes in workers exposed to flour dust. Hence, worker protection measures should be consistently adopted and enforced at the workplace. © The Author(s) 2015.
Gautam, Bal K; Henderson, Gregg
2011-10-01
Foraging groups of Formosan subterranean termites, Coptotermes formosanus Shiraki were tested for their relative humidity (RH) preference in a humidity gradient arena in the laboratory at a constant temperature of 26°C. Five RH levels (9%, 33%, 53%, 75%, and 98%) were maintained in the test arena comprising of a series of closed containers by using dry silica gel, saturated salt solutions, or distilled water alone. Termites gradually aggregated to the highest RH chamber in the arena. After 1 h, a significantly greater percentage of termites (≈46%) aggregated to the highest RH chamber (98%) than to the lower RH chambers (≤75%). After 12 h, > 97% of the termites aggregated to the 98% RH chamber. In survival tests, where termites were exposed to 15 combinatorial treatments of five RH levels (9%, 33%, 53%, 75%, and 98%) and three temperatures (20°C, 28°C, and 36°C) for a week, the survival was significantly influenced by RH, temperature, and their interaction. A significantly higher mortality was observed on termites exposed to ≤75% RH chambers than to 98% RH chamber at the three temperatures and significantly lower survival was found at 36°C than at 28°C or 20°C. The combination of temperature and RH plays an important role in the survival of C. formosanus.
Girish, T N; Pradeep, B E; Parkash, Ravi
2018-05-04
Insects in tropical wet or dry seasons are likely to cope with starvation stress through plastic changes (developmental as well as adult acclimation) in energy metabolites. Control and experimental groups of Zaprionus indianus flies were reared under wet or dry conditions, but adults were acclimated at different thermal or humidity conditions. Adult flies of the control group were acclimated at 27°C and low (50%) or high (60%) relative humidity (RH). For experimental groups, adult flies were acclimated at 32°C for 1 to 6 days and under low (40%) or high (70%) RH. For humidity acclimation, adult flies were acclimated at 27°C but under low (40%) or high (70%) RH for 1 to 6 days. Plastic changes in experimental groups as compared with the control group (developmental as well as adult acclimation) revealed significant accumulation of body lipids owing to thermal or humidity acclimation of wet season flies, but low humidity acclimation did not change the level of body lipids in dry season flies. Starvation resistance and body lipids were higher in the males of dry season flies but in the females of wet season flies. Adults acclimated under different thermal or humidity conditions exhibited changes in the rate of utilization of body lipids, carbohydrates and proteins. Adult acclimation of wet or dry season flies revealed plastic changes in mean daily fecundity; and a reduction in fecundity under starvation. Thus, thermal or humidity acclimation of adults revealed plastic changes in energy metabolites to support starvation resistance of wet or dry season flies. © 2018. Published by The Company of Biologists Ltd.
Method and apparatus for controlling fuel/air mixture in a lean burn engine
Kubesh, John Thomas; Dodge, Lee Gene; Podnar, Daniel James
1998-04-07
The system for controlling the fuel/air mixture supplied to a lean burn engine when operating on natural gas, gasoline, hydrogen, alcohol, propane, butane, diesel or any other fuel as desired. As specific humidity of air supplied to the lean burn engine increases, the oxygen concentration of exhaust gas discharged by the engine for a given equivalence ratio will decrease. Closed loop fuel control systems typically attempt to maintain a constant exhaust gas oxygen concentration. Therefore, the decrease in the exhaust gas oxygen concentration resulting from increased specific humidity will often be improperly attributed to an excessive supply of fuel and the control system will incorrectly reduce the amount of fuel supplied to the engine. Also, the minimum fuel/air equivalence ratio for a lean burn engine to avoid misfiring will increase as specific humidity increases. A relative humidity sensor to allow the control system to provide a more enriched fuel/air mixture at high specific humidity levels. The level of specific humidity may be used to compensate an output signal from a universal exhaust gas oxygen sensor for changing oxygen concentrations at a desired equivalence ratio due to variation in specific humidity specific humidity. As a result, the control system will maintain the desired efficiency, low exhaust emissions and power level for the associated lean burn engine regardless of the specific humidity level of intake air supplied to the lean burn engine.
NASA Astrophysics Data System (ADS)
Zuo, Hao-Ran; Cao, Gui-Ping; Wang, Meng; Zhang, Huan-Huan; Song, Chen-Chen; Fang, Xu; Wang, Tao
2018-03-01
Forward osmosis (FO) has received great interest for its considerable potential in a wide range of fields. In this work, the morphology and performance of FO membrane were regulated by adjusting the atmosphere humidity (HC) of casting procedure. The polysulfone support layer was casted under various atmosphere humidity levels ranging from 40% to 80%. By multi-techniques such as SEM, AFM, and XPS, it was proved that the atmosphere humidity had modified the surface morphology and thickness of the skin layer in support layer, which contributed up to 90% of the structure parameter, resulting in distinct morphology, thickness, and cross-linking degree of active layer. The active layer with sparse bead-like wrinkles on the smooth surface of support layer casted at HC = 65% showed the highest water permeability [26.9 (L/m2 h MPa)] and considerable low salt permeability [0.0390 (L/m2 h)]. It was found that the water flux of FO-65 was 27% and 46% higher than that of FO-80 in AL-DS and AL-FS mode, respectively, and the salt rejection was as high as 98%. Our work highlighted the importance of considering the effect of atmosphere humidity during casting when design an FO membrane for appropriate performance.
Güler, I; Burunkaya, M
2002-01-01
Relative humidity levels of an incubator were measured and controlled. An ultrasonic nebulizer system as an active humidifier was used to humidify the incubator environment. An integrated circuit-type humidity sensor was used to measure the humidity level of the incubator environment. Measurement and control processes were achieved by a PIC microcontroller. The high-performance and high-speed PIC provided the flexibility of the system. The developed system can be used effectively for the intensive care of newborns and/or premature babies. Since the humidifier generates an aerosol in ambient conditions, it is possible to provide the high relative humidity level for therapeutic and diagnostic purposes in medicine.
NASA Astrophysics Data System (ADS)
Okamoto-Mizuno, Kazue; Tsuzuki, Kazuyo; Mizuno, Koh
2005-03-01
This study sought to investigate the effects of humid heat exposure in later sleep segments on sleep stages and body temperature in humans. The subjects were eight healthy males, from whom informed consent had been obtained. The experiments were carried out under three different sets of conditions: a control climate [air temperature (Ta)=26°C, relative humidity (RH)=50%] (C); a humid heat climate (Ta=32°C, RH=80%) (H); and a humid heat exposure in later sleep segments (C for the first 3 h 45 min, followed by a 30-min transition to H, which was then maintained for the last 3 h 45 min) (C H). Electroencephalogram, EOG, and mental electromyogram, rectal temperature (Tre), and skin temperature (Tsk) were continuously measured. The total amount of wakefulness was significantly increased in H compared to C H or C. Compared to C, wakefulness in C H and H was significantly increased during later sleep segments. Tre and mean Tsk were significantly higher in H than in C H or C. In C H, Tsk and Tre increased to levels equal to those observed in H after Ta and RH increase. Whole body sweat loss was significantly lower in C H and C than in H. These results suggest that humid heat exposure in the later sleep segment reduces thermal load as compared to full-night humid heat exposure. In daily life, the use of air conditioning in the initial sleep hours can protect sleep and thermoregulation.
Athanassiou, Christos G; Kavallieratos, Nickolas G; Rumbos, Christos I; Kontodimas, Demetrius C
2017-01-01
A series of laboratory bioassays were conducted for the evaluation of the insecticidal efficacy of an isolate of Metarhizium anisopliae (Metschnikoff) Sorokin (Ascomycota: Hypocreales) against larvae of the Mediterranean flour moth, Ephestia kuehniella Zeller (Lepidoptera: Pyralidae), under various temperature-relative humidity (r.h.) conditions. The fungus was applied at four doses (0, 8 × 106, 8 × 108, and 8 × 1010 conidia ml-1) on wheat and insect mortality was assessed after exposure of 1, 2, 7, and 14 d. Bioassays were conducted at three temperatures (20, 25, and 30 °C) and two r.h. levels (55 and 75%). Although complete control was not achieved in any case, the fungus provided a considerable level of insect control. Mortality of E. kuehniella larvae on wheat treated with M. anisopliae ranged between 41.1 and 93.3% after 14 d of exposure, whereas the respective mortality levels in control dishes never exceeded 28.3%. The increase of temperature resulted in most cases to higher efficacy, indicating that temperature is an important factor for the performance of the fungus. In contrast, in most cases r.h. did not significantly affect the efficacy of the fungus, at least for the humidity levels tested. © The Author 2017. Published by Oxford University Press on behalf of the Entomological Society of America.
The anthropogenic influence on heat and humidity in the US Midwest
NASA Astrophysics Data System (ADS)
Inda Diaz, H. A.; O'Brien, T. A.; Stone, D. A.
2016-12-01
Heatwaves, and extreme temperatures in general, have a wide range of negative impacts on society, and particularly on human health. In addition to temperature, humidity plays a key role in regulating human body temperature, with higher humidities tending to reduce the effectiveness of perspiration. There is recent theoretical and observational evidence that co-occurring extreme heat and humidity can potentially have a much more dramatic impact on human health than either extreme in isolation. There is an abundance of observational evidence indicating that anthropogenic increases in greenhouse gas (GHG) forcing have contributed to an increase in the intensity and frequency of temperature extremes on a global scale. However, aside from purely thermodynamically-driven increases in near-surface humidity, there is a paucity of similar evidence for anthropogenic impacts on humidity. Thermodynamic scaling would suggest that air masses originating from the ocean would be associated with higher specific humidity in a warmer world, and transpiration from irrigated crops could further increase humidity in warm air masses. In order to explore the role of anthropogenic GHG forcing on the co-occurrence of temperature and humidity extremes in the Midwestern United States (US), we evaluate a large ensemble of global climate model simulations with and without anthropogenic GHG forcing. In particular, we examine differences between the probability distributions of near-surface temperature, humidity, wet-bulb temperature, and the joint distribution of temperature and humidity in this ensemble. Finally, we explore augmenting this experimental framework with additional simulations to explore the role of anthropogenic changes in the land surface, and in particular irrigated crops, on co-occurring extreme heat and humidity.
Amin, Aeshna; Dantuluri, Ajay Kumar Raju; Bansal, Arvind Kumar
2012-01-17
A previous work from our lab reported the higher sorption of lipophilic preservatives in LDPE form-fill-seal packs that were stored at 75% relative humidity (RH) as against 25% RH. The aim of the present work was to investigate structural changes taking place in LDPE on exposure to higher humidity. The crystallinity of LDPE, determined by differential scanning calorimetry, was found to be similar for the packs charged at both humidity conditions. Dielectric spectroscopy (1.0E-02 Hz to 1.0E02 Hz in the temperature range of 75-87°C), however, showed faster α relaxation of LDPE films exposed to higher humidity. The activation energy of α relaxations was lower at 75% RH (99.735 kJ/mol) than at 25% RH (113.112 kJ/mol) after two weeks of storage. This work presents previously unreported evidence of the plasticization effect of water on LDPE, using dielectric spectroscopy. Furthermore, changes in α relaxation on exposure to humidity support the latest theory of its origin to be from the constrained amorphous regions. The authors suggest the employment of extreme humidity conditions (low and high), during accelerated stability studies of aqueous products in plastic packs to track the sorption loss of formulation components. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Walker, Iain; Ticci, Sara
Past field research and simulation studies have shown that high performance homes experience elevated indoor humidity levels for substantial portions of the year in humid climates. This is largely the result of lower sensible cooling loads, which reduces the moisture removed by the cooling system. These elevated humidity levels lead to concerns about occupant comfort, health and building durability. Use of mechanical ventilation at rates specified in ASHRAE Standard 62.2-2013 are often cited as an additional contributor to humidity problems in these homes. Past research has explored solutions, including supplemental dehumidification, cooling system operational enhancements and ventilation system design (e.g.,more » ERV, supply, exhaust, etc.). This project’s goal is to develop and demonstrate (through simulations) smart ventilation strategies that can contribute to humidity control in high performance homes. These strategies must maintain IAQ via equivalence with ASHRAE Standard 62.2-2013. To be acceptable they must not result in excessive energy use. Smart controls will be compared with dehumidifier energy and moisture performance. This work explores the development and performance of smart algorithms for control of mechanical ventilation systems, with the objective of reducing high humidity in modern high performance residences. Simulations of DOE Zero-Energy Ready homes were performed using the REGCAP simulation tool. Control strategies were developed and tested using the Residential Integrated Ventilation (RIVEC) controller, which tracks pollutant exposure in real-time and controls ventilation to provide an equivalent exposure on an annual basis to homes meeting ASHRAE 62.2-2013. RIVEC is used to increase or decrease the real-time ventilation rate to reduce moisture transport into the home or increase moisture removal. This approach was implemented for no-, one- and two-sensor strategies, paired with a variety of control approaches in six humid climates (Miami, Orlando, Houston, Charleston, Memphis and Baltimore). The control options were compared to a baseline system that supplies outdoor air to a central forced air cooling (and heating) system (CFIS) that is often used in hot humid climates. Simulations were performed with CFIS ventilation systems operating on a 33% duty-cycle, consistent with 62.2-2013. The CFIS outside airflow rates were set to 0%, 50% and 100% of 62.2-2013 requirements to explore effects of ventilation rate on indoor high humidity. These simulations were performed with and without a dehumidifier in the model. Ten control algorithms were developed and tested. Analysis of outdoor humidity patterns facilitated smart control development. It was found that outdoor humidity varies most strongly seasonally—by month of the year—and that all locations follow the similar pattern of much higher humidity during summer. Daily and hourly variations in outdoor humidity were found to be progressively smaller than the monthly seasonal variation. Patterns in hourly humidity are driven by diurnal daily patterns, so they were predictable but small, and were unlikely to provide much control benefit. Variation in outdoor humidity between days was larger, but unpredictable, except by much more complex climate models. We determined that no-sensor strategies might be able to take advantage of seasonal patterns in humidity, but that real-time smart controls were required to capture variation between days. Sensor-based approaches are also required to respond dynamically to indoor conditions and variations not considered in our analysis. All smart controls face trade-offs between sensor accuracy, cost, complexity and robustness.« less
Floral humidity as a reliable sensory cue for profitability assessment by nectar-foraging hawkmoths.
von Arx, Martin; Goyret, Joaquín; Davidowitz, Goggy; Raguso, Robert A
2012-06-12
Most research on plant-pollinator communication has focused on sensory and behavioral responses to relatively static cues. Floral rewards such as nectar, however, are dynamic, and foraging animals will increase their energetic profit if they can make use of floral cues that more accurately indicate nectar availability. Here we document such a cue--transient humidity gradients--using the night blooming flowers of Oenothera cespitosa (Onagraceae). The headspace of newly opened flowers reaches levels of about 4% above ambient relative humidity due to additive evapotranspirational water loss through petals and water-saturated air from the nectar tube. Floral humidity plumes differ from ambient levels only during the first 30 min after anthesis (before nectar is depleted in wild populations), whereas other floral traits (scent, shape, and color) persist for 12-24 h. Manipulative experiments indicated that floral humidity gradients are mechanistically linked to nectar volume and therefore contain information about energy rewards to floral visitors. Behavioral assays with Hyles lineata (Sphingidae) and artificial flowers with appropriate humidity gradients suggest that these hawkmoth pollinators distinguish between subtle differences in relative humidity when other floral cues are held constant. Moths consistently approached and probed flowers with elevated humidity over those with ambient humidity levels. Because floral humidity gradients are largely produced by the evaporation of nectar itself, they represent condition-informative cues that facilitate remote sensing of floral profitability by discriminating foragers. In a xeric environment, this level of honest communication should be adaptive when plant reproductive success is pollinator limited, due to intense competition for the attention of a specialized pollinator.
Floral humidity as a reliable sensory cue for profitability assessment by nectar-foraging hawkmoths
von Arx, Martin; Goyret, Joaquín; Davidowitz, Goggy; Raguso, Robert A.
2012-01-01
Most research on plant–pollinator communication has focused on sensory and behavioral responses to relatively static cues. Floral rewards such as nectar, however, are dynamic, and foraging animals will increase their energetic profit if they can make use of floral cues that more accurately indicate nectar availability. Here we document such a cue—transient humidity gradients—using the night blooming flowers of Oenothera cespitosa (Onagraceae). The headspace of newly opened flowers reaches levels of about 4% above ambient relative humidity due to additive evapotranspirational water loss through petals and water-saturated air from the nectar tube. Floral humidity plumes differ from ambient levels only during the first 30 min after anthesis (before nectar is depleted in wild populations), whereas other floral traits (scent, shape, and color) persist for 12–24 h. Manipulative experiments indicated that floral humidity gradients are mechanistically linked to nectar volume and therefore contain information about energy rewards to floral visitors. Behavioral assays with Hyles lineata (Sphingidae) and artificial flowers with appropriate humidity gradients suggest that these hawkmoth pollinators distinguish between subtle differences in relative humidity when other floral cues are held constant. Moths consistently approached and probed flowers with elevated humidity over those with ambient humidity levels. Because floral humidity gradients are largely produced by the evaporation of nectar itself, they represent condition-informative cues that facilitate remote sensing of floral profitability by discriminating foragers. In a xeric environment, this level of honest communication should be adaptive when plant reproductive success is pollinator limited, due to intense competition for the attention of a specialized pollinator. PMID:22645365
Drylands face potential threat under 2 °C global warming target
NASA Astrophysics Data System (ADS)
Huang, Jianping; Yu, Haipeng; Dai, Aiguo; Wei, Yun; Kang, Litai
2017-06-01
The Paris Agreement aims to limit global mean surface warming to less than 2 °C relative to pre-industrial levels. However, we show this target is acceptable only for humid lands, whereas drylands will bear greater warming risks. Over the past century, surface warming over global drylands (1.2-1.3 °C) has been 20-40% higher than that over humid lands (0.8-1.0 °C), while anthropogenic CO2 emissions generated from drylands (~230 Gt) have been only ~30% of those generated from humid lands (~750 Gt). For the twenty-first century, warming of 3.2-4.0 °C (2.4-2.6 °C) over drylands (humid lands) could occur when global warming reaches 2.0 °C, indicating ~44% more warming over drylands than humid lands. Decreased maize yields and runoff, increased long-lasting drought and more favourable conditions for malaria transmission are greatest over drylands if global warming were to rise from 1.5 °C to 2.0 °C. Our analyses indicate that ~38% of the world's population living in drylands would suffer the effects of climate change due to emissions primarily from humid lands. If the 1.5 °C warming limit were attained, the mean warming over drylands could be within 3.0 °C therefore it is necessary to keep global warming within 1.5 °C to prevent disastrous effects over drylands.
Tozer, Mark G; Ooi, Mark K J
2014-09-01
Seed dormancy enhances fitness by preventing seeds from germinating when the probability of seedling survival and recruitment is low. The onset of physical dormancy is sensitive to humidity during ripening; however, the implications of this mechanism for seed bank dynamics have not been quantified. This study proposes a model that describes how humidity-regulated dormancy onset may control the accumulation of a dormant seed bank, and seed experiments are conducted to calibrate the model for an Australian Fabaceae, Acacia saligna. The model is used to investigate the impact of climate on seed dormancy and to forecast the ecological implications of human-induced climate change. The relationship between relative humidity and dormancy onset was quantified under laboratory conditions by exposing freshly matured non-dormant seeds to constant humidity levels for fixed durations. The model was field-calibrated by measuring the response of seeds exposed to naturally fluctuating humidity. The model was applied to 3-hourly records of humidity spanning the period 1972-2007 in order to estimate both temporal variability in dormancy and spatial variability attributable to climatic differences among populations. Climate change models were used to project future changes in dormancy onset. A sigmoidal relationship exists between dormancy and humidity under both laboratory and field conditions. Seeds ripened under field conditions became dormant following very short exposure to low humidity (<20 %). Prolonged exposure at higher humidity did not increase dormancy significantly. It is predicted that populations growing in a temperate climate produce 33-55 % fewer dormant seeds than those in a Mediterranean climate; however, dormancy in temperate populations is predicted to increase as a result of climate change. Humidity-regulated dormancy onset may explain observed variation in physical dormancy. The model offers a systematic approach to modelling this variation in population studies. Forecast changes in climate have the potential to alter the seed bank dynamics of species with physical dormancy regulated by this mechanism, with implications for their capacity to delay germination and exploit windows for recruitment. © The Author 2014. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Tozer, Mark G.; Ooi, Mark K. J.
2014-01-01
Background and aims Seed dormancy enhances fitness by preventing seeds from germinating when the probability of seedling survival and recruitment is low. The onset of physical dormancy is sensitive to humidity during ripening; however, the implications of this mechanism for seed bank dynamics have not been quantified. This study proposes a model that describes how humidity-regulated dormancy onset may control the accumulation of a dormant seed bank, and seed experiments are conducted to calibrate the model for an Australian Fabaceae, Acacia saligna. The model is used to investigate the impact of climate on seed dormancy and to forecast the ecological implications of human-induced climate change. Methods The relationship between relative humidity and dormancy onset was quantified under laboratory conditions by exposing freshly matured non-dormant seeds to constant humidity levels for fixed durations. The model was field-calibrated by measuring the response of seeds exposed to naturally fluctuating humidity. The model was applied to 3-hourly records of humidity spanning the period 1972–2007 in order to estimate both temporal variability in dormancy and spatial variability attributable to climatic differences among populations. Climate change models were used to project future changes in dormancy onset. Key Results A sigmoidal relationship exists between dormancy and humidity under both laboratory and field conditions. Seeds ripened under field conditions became dormant following very short exposure to low humidity (<20 %). Prolonged exposure at higher humidity did not increase dormancy significantly. It is predicted that populations growing in a temperate climate produce 33–55 % fewer dormant seeds than those in a Mediterranean climate; however, dormancy in temperate populations is predicted to increase as a result of climate change. Conclusions Humidity-regulated dormancy onset may explain observed variation in physical dormancy. The model offers a systematic approach to modelling this variation in population studies. Forecast changes in climate have the potential to alter the seed bank dynamics of species with physical dormancy regulated by this mechanism, with implications for their capacity to delay germination and exploit windows for recruitment. PMID:25015069
NASA Astrophysics Data System (ADS)
Salas, Y.; Guerrero, L.; Blanco, J.; Jimenez, C.; Vera-Monroy, S. P.; Mejía-Camacho, A.
2017-12-01
In this work, DC electrochemical techniques were used to determine the corrosion rate of copper and stainless-steel electrodes used in grounding, varying the level of humidity, in sandy loam and clay loam soils. The maximum corrosion potentials were: for copper -211 and -236mV and for stainless steel of -252 and -281mV, in sandy loam and clay loam respectively, showing that in sandy loam the values are higher, about 30mV. The mechanism by which steel controls corrosion is by diffusion, whereas in copper it is carried out by transfer of mass and charge, which affects the rate of corrosion, which in copper reached a maximum value of 5mm/yr and in Steel 0.8mm/yr, determined by Tafel approximations. The behaviour of the corrosion rate was mathematically adjusted to an asymptotic model that faithfully explains the C.R. as a function of humidity, however, it is necessary to define the relation between the factor □ established in the model and the precise characteristics of the soil, such as the permeability or quantity of ions present.
Xiang, Fan; Harrison, Simone; Nowak, Madeleine; Kimlin, Michael; Van der Mei, Ingrid; Neale, Rachel E; Sinclair, Craig; Lucas, Robyn M
2015-02-01
To examine the effects of meteorological factors on weekend sun exposure behaviours and personal received dose of ultraviolet radiation (UVR) in Australian adults. Australian adults (n=1002) living in Townsville (19°S, 146°E), Brisbane (27°S, 153°E), Canberra (35°S, 149°E) and Hobart (43°S, 147°E) were recruited between 2009 and 2010. Data on sun exposure behaviours were collected by daily sun exposure dairies; personal UVR exposure was measured with a polysulphone dosimeter. Meteorological data were obtained from the Australian Bureau of Meteorology; ambient UVR levels were estimated using the Ozone Monitoring Instrument data. Higher daily maximum temperatures were associated with reduced likelihood of wearing a long-sleeved shirt or wearing long trousers in Canberra and Hobart, and higher clothing-adjusted UVR dose in Canberra. Higher daily humidity was associated with less time spent outdoors in Canberra. Higher ambient UVR level was related to a greater clothing-adjusted personal UVR dose in Hobart and a greater likelihood of using sunscreen in Townsville. The current findings enhance our understanding of the impact of weather conditions on the population's sun exposure behaviours. This information will allow us to refine current predictive models for UVR-related diseases, and guide future health service and health promotion needs. Copyright © 2015 Elsevier B.V. All rights reserved.
Optimization of steam generators of NPP with WWER in operation with variable load
NASA Astrophysics Data System (ADS)
Parchevskii, V. M.; Shchederkina, T. E.; Gur'yanova, V. V.
2017-11-01
The report addresses the issue of the optimal water level in the horizontal steam generators of NPP with WWER. On the one hand, the level needs to be kept at the lower limit of the allowable range, as gravity separation, steam will have the least humidity and the turbine will operate with higher efficiency. On the other hand, the higher the level, the greater the supply of water in the steam generator, and therefore the higher the security level of the unit, because when accidents involving loss of cooling of the reactor core, the water in the steam generators, can be used for cooling. To quantitatively compare the damage from higher level to the benefit of improving the safety was assessed of the cost of one cubic meter of water in the steam generators, the formulated objective function of optimal levels control. This was used two-dimensional separation characteristics of steam generators. It is demonstrated that the security significantly shifts the optimal values of the levels toward the higher values, and this bias is greater the lower the load unit.
A humidity sensing organic-inorganic composite for environmental monitoring.
Ahmad, Zubair; Zafar, Qayyum; Sulaiman, Khaulah; Akram, Rizwan; Karimov, Khasan S
2013-03-14
In this paper, we present the effect of varying humidity levels on the electrical parameters and the multi frequency response of the electrical parameters of an organic-inorganic composite (PEPC+NiPc+Cu2O)-based humidity sensor. Silver thin films (thickness ~200 nm) were primarily deposited on plasma cleaned glass substrates by the physical vapor deposition (PVD) technique. A pair of rectangular silver electrodes was formed by patterning silver film through standard optical lithography technique. An active layer of organic-inorganic composite for humidity sensing was later spun coated to cover the separation between the silver electrodes. The electrical characterization of the sensor was performed as a function of relative humidity levels and frequency of the AC input signal. The sensor showed reversible changes in its capacitance with variations in humidity level. The maximum sensitivity ~31.6 pF/%RH at 100 Hz in capacitive mode of operation has been attained. The aim of this study was to increase the sensitivity of the previously reported humidity sensors using PEPC and NiPc, which has been successfully achieved.
A Humidity Sensing Organic-Inorganic Composite for Environmental Monitoring
Ahmad, Zubair; Zafar, Qayyum; Sulaiman, Khaulah; Akram, Rizwan; Karimov, Khasan S.
2013-01-01
In this paper, we present the effect of varying humidity levels on the electrical parameters and the multi frequency response of the electrical parameters of an organic-inorganic composite (PEPC+NiPc+Cu2O)-based humidity sensor. Silver thin films (thickness ∼200 nm) were primarily deposited on plasma cleaned glass substrates by the physical vapor deposition (PVD) technique. A pair of rectangular silver electrodes was formed by patterning silver film through standard optical lithography technique. An active layer of organic-inorganic composite for humidity sensing was later spun coated to cover the separation between the silver electrodes. The electrical characterization of the sensor was performed as a function of relative humidity levels and frequency of the AC input signal. The sensor showed reversible changes in its capacitance with variations in humidity level. The maximum sensitivity ∼31.6 pF/%RH at 100 Hz in capacitive mode of operation has been attained. The aim of this study was to increase the sensitivity of the previously reported humidity sensors using PEPC and NiPc, which has been successfully achieved. PMID:23493124
NASA Technical Reports Server (NTRS)
Meng, P. R.; Skorobatckyi, M.; Cosgrove, D. V.; Kempke, E. E., Jr.
1976-01-01
A carbureted aircraft engine was operated over a range of test conditions to establish the exhaust levels over the EPA seven-mode emissions cycle. Baseline (full rich production limit) exhaust emissions at an induction air temperature of 59 F and near zero relative humidity were 90 percent of the EPA standard for HC, 35 percent for NOx, and 161 percent for CO. Changes in ignition timing around the standard 25 deg BTDC from 30 deg BTDC to 20 deg BTDC had little effect on the exhaust emissions. Retarding the timing to 15 deg BTDC increased both the HC and CO emissions and decreased NOx emissions. HC and CO emissions decreased as the carburetor was leaned out, while NOx emissions increased. The EPA emission standards were marginally achieved at two leanout conditions. Variations in the quantity of cooling air flow over the engine had no effect on exhaust emissions. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased.
Ortega-Insaurralde, I; Toloza, A C; Gonzalez-Audino, P; Mougabure-Cueto, G A; Alvarez-Costa, A; Roca-Acevedo, G; Picollo, M I
2015-09-01
In this work, we evaluated the effect of environmental variables such as temperature, humidity, and light on the locomotor activity of Pediculus humanus capitis. In addition, we used selected conditions of temperature, humidity, and light to study the effects of cypermethrin and N,N-diethyl-3-methylbenzamide (DEET) on the locomotor activity of head lice. Head lice increased their locomotor activity in an arena at 30°C compared with activity at 20°C. When we tested the influence of the humidity level, the locomotor activity of head lice showed no significant differences related to humidity level, both at 30°C and 20°C. Concerning light influence, we observed that the higher the intensity of light, the slower the movement of head lice. We also demonstrated that sublethal doses of toxics may alter locomotor activity in adults of head lice. Sublethal doses of cypermethrin induced hyperactivated responses in adult head lice. Sublethal doses of DEET evocated hypoactivated responses in head lice. The observation of stereotyped behavior in head lice elicited by toxic compounds proved that measuring locomotor activity in an experimental set-up where environmental conditions are controlled would be appropriate to evaluate compounds of biological importance, such as molecules involved in the host-parasite interaction and intraspecific relationships. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhu, Qing; Shih, Wan Y.; Shih, Wei-Heng
2007-01-01
We have examined non-insulated PZT/gold-coated glass cantilevers for real-time, label-free detection of Salmonella t. by partial dipping at any relative humidity. The PZT/gold-coated glass cantilevers were consisted of a 0.127 mm thick PZT layer about 0.8 mm long, 2 mm wide bonded to a 0.15 mm thick gold-coated glass layer with a 3.0 mm long gold-coated glass tip for detection. We showed that by placing the water level at the nodal point, about 0.8 mm from the free end of the gold-glass tip, there was a 1-hr window in which the resonance frequency was stable despite the water level change by evaporation at 20% relative humidity or higher. By dipping the cantilevers to their nodal point, we were able to do real-time, label-free detection without background resonance frequency corrections at any relative humidity. The partially dipped PZT/gold-coated glass cantilever exhibited mass detection sensitivity, Δm/Δf = −5×10−11g/Hz, and a detection concentration sensitivity, 5×103 cells/ml in 2 ml of liquid, which was about two orders of magnitude lower than that of a 5 MHz QCM. It was also about two orders of magnitude lower than the infection dosage and one order of magnitude lower that the detection limit of a commercial Raptor sensor. PMID:22872784
Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hacke, Peter L; Rodriguez, Miguel; Kempe, Michael D
An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.
Design, Development, and Testing of a Water Vapor Exchanger for Spacecraft Life Support Systems
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Micka, Daniel J.; Chepko, Ariane B.; Rule, Kyle C.; Anderson, Molly S.
2016-01-01
Thermal and environmental control systems for future exploration spacecraft must meet challenging requirements for efficient operation and conservation of resources. Maximizing the use of regenerative systems and conserving water are critical considerations. This paper describes the design, development, and testing of an innovative water vapor exchanger (WVX) that can minimize the amount of water absorbed in, and vented from, regenerative CO2 removal systems. Key design requirements for the WVX are high air flow capacity (suitable for a crew of six), very high water recovery, and very low pressure losses. We developed fabrication and assembly methods that enable high-efficiency mass transfer in a uniform and stable array of Nafion tubes. We also developed analysis and design methods to compute mass transfer and pressure losses. We built and tested subscale units sized for flow rates of 2 and 5 cu ft/min (3.4–8.5 cu m/hr). Durability testing demonstrated that a stable core geometry was sustained over many humid/dry cycles. Pressure losses were very low (less than 0.5 in. H2O (125 Pa) total) and met requirements at prototypical flow rates. We measured water recovery efficiency across a range of flow rates and humidity levels that simulate the range of possible cabin conditions. We measured water recovery efficiencies in the range of 80 to 90%, with the best efficiency at lower flow rates and higher cabin humidity levels. We compared performance of the WVX with similar units built using an unstructured Nafion tube bundle. The WVX achieves higher water recovery efficiency with nearly an order of magnitude lower pressure drop than unstructured tube bundles. These results show that the WVX provides uniform flow through flow channels for both the humid and dry streams and can meet requirements for service on future exploration spacecraft. The WVX technology will be best suited for long-duration exploration vehicles that require regenerative CO2 removal systems while needing to conserve water.
2013-01-01
Background Low levels of relative humidity are known to decrease the lifespan of mosquitoes. However, most current models of malaria transmission do not account for the effects of relative humidity on mosquito survival. In the Sahel, where relative humidity drops to levels <20% for several months of the year, we expect relative humidity to play a significant role in shaping the seasonal profile of mosquito populations. Here, we present a new formulation for Anopheles gambiae sensu lato (s.l.) mosquito survival as a function of temperature and relative humidity and investigate the effect of humidity on simulated mosquito populations. Methods Using existing observations on relationships between temperature, relative humidity and mosquito longevity, we developed a new equation for mosquito survival as a function of temperature and relative humidity. We collected simultaneous field observations on temperature, wind, relative humidity, and anopheline mosquito populations for two villages from the Sahel region of Africa, which are presented in this paper. We apply this equation to the environmental data and conduct numerical simulations of mosquito populations using the Hydrology, Entomology and Malaria Transmission Simulator (HYDREMATS). Results Relative humidity drops to levels that are uncomfortable for mosquitoes at the end of the rainy season. In one village, Banizoumbou, water pools dried up and interrupted mosquito breeding shortly after the end of the rainy season. In this case, relative humidity had little effect on the mosquito population. However, in the other village, Zindarou, the relatively shallow water table led to water pools that persisted several months beyond the end of the rainy season. In this case, the decrease in mosquito survival due to relative humidity improved the model’s ability to reproduce the seasonal pattern of observed mosquito abundance. Conclusions We proposed a new equation to describe Anopheles gambiae s.l. mosquito survival as a function of temperature and relative humidity. We demonstrated that relative humidity can play a significant role in mosquito population and malaria transmission dynamics. Future modeling work should account for these effects of relative humidity. PMID:23938022
Measurements of upper troposheric humidity at low temperatures during CRYSTAL-FACE
NASA Technical Reports Server (NTRS)
Herman, Robert L.; Heymsfield, Andrew J.; Ridley, Brian A.; Bui, Paul T.
2003-01-01
Aircraft condensation trails (contrails) and thin cirrus were studied by instruments on the NASA WB-57F high-altitude aircraft during contrails and optically thing cirrus are contrasted by different levels of supersaturation with respect to ice. During the July 13, 2002, flight of the WB-57F aircraft intercepted visible contrails produced by both the WB-57F and ER-2 aircraft. These contrails were located immediately below the local tropopause, where ambient temperatures were very low (-76 degree C). The contrails were clearly indicated by an abrupt increase in NO and a simultaneous, abrupt decrease in ice supersaturation. With in the contrail, the relative humidity was close to 130% with respect to ice, higher than expected from theory. Outside the contrails was a persistent layer of subvisible currus extending from approximately 13 to 15 km altitude. This layer was characterized y significant supersaturations because the ambient concentrations of ice particles were insufficient to significantly deplete the ice supersaturation. We will discuss in situ measurements and models simulations of humidity.
Humidity plays an important role in the PM₂.₅ pollution in Beijing.
Cheng, Yuan; He, Ke-Bin; Du, Zhen-Yu; Zheng, Mei; Duan, Feng-Kui; Ma, Yong-Liang
2015-02-01
Heavily-polluted PM₂.₅ (fine particulate matter) episodes frequently impacting Beijing, especially during winter, have become a substantial concern. We found that during winter, the daily variation of PM2.5 in Beijing tracked the pattern of relative humidity (RH). With the increase of PM₂.₅ (or RH), water-soluble components (especially inorganic ions) became more abundant, and the water-soluble organic carbon to organic carbon ratios increased. The nitrate to sulfate ratios also exhibited dependence on RH, and were higher than those measured about a decade ago, consistent with the increasing trend of nitrogen oxides emissions. Surprisingly, the ratios of water-insoluble organic carbon to elemental carbon showed significant increase at high RH levels, presumably indicating the formation of secondary organic aerosol that is not soluble in water. In addition, humid winters were occasionally identified during 1996-2013 which are expected to be favorable for the formation of air pollution episodes with high PM₂.₅ concentrations. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ng, Tsz Wai; Chan, Wing Lam; Lai, Ka Man
2017-12-01
Other than the needs for infection control to investigate the survival and inactivation of airborne bacterial pathogens, there has been a growing interest in exploring bacterial communities in the air and the effect of environmental variables on them. However, the innate biological mechanism influencing the bacterial viability is still unclear. In this study, a mutant-based approach, using Escherichia coli as a model, was used to prove the concept that common stress-response genes are important for airborne survival of bacteria. Mutants with a single gene knockout that are known to respond to general stress (rpoS) and oxidative stress (oxyR, soxR) were selected in the study. Low relative humidity (RH), 30-40% was more detrimental to the bacteria than high RH, >90%. The log reduction of ∆rpoS was always higher than that of the parental strain at all RH levels but the ∆oxyR had a higher log reduction than the parental strain at intermediate RH only. ∆soxR had the same viability compared to the parental strain at all RH levels. The results hint that although different types and levels of stress are produced under different RH conditions, stress-response genes always play a role in the bacterial viability. This study is the first reporting the association between stress-response genes and viability of airborne bacteria.
Optimizing Street Canyon Orientation for Rajarhat Newtown, Kolkata, India
NASA Astrophysics Data System (ADS)
De, Bhaskar; Mukherjee, Mahua
2017-12-01
Air temperature in urban street canyons is increased due to the morphed urban geometry, increased surface area, decreased long wave radiation and evapo-transpiration, different thermo-physical properties of surface materials and anthropogenic heat which results in thermal discomfort. Outdoor thermal stress can be mitigated substantially by properly orienting the canyons. It is crucial for the urban planners and designers to orient street canyons optimally considering variable local climatic context. It is important especially for cities in warm humid climatic context as these cities receive higher insolation with higher relative humidity and low level macro wind flow. This paper examines influence of canyon orientation on outdoor thermal comfort and proposes the optimum canyon orientation for the Rajarhat Newtown, Kolkata - a city in warm humid climate zone. Different scenarios are generated with different orientations. Change in air temperature, wind speed, Mean Radiant Temperature (MRT) and Physiological Equivalent Temperature (PET) of different scenarios are compared to find out the optimum orientation by parametric simulation in ENVI_met. Analysing the simulation results it is observed that orientation angle between 30°-60° to north performs the best for the study area of the Rajarhat Newtown. The findings of this research will be helpful for the planners to orient the street canyons optimally for future development and extension of the Rajarhat Newtown, Kolkata.
Vida, Stephen; Durocher, Martin; Ouarda, Taha B M J; Gosselin, Pierre
2012-11-01
This study examined whether the number of emergency department visits for "mental and psychosocial problems" varies with temperature or humidity. The number of visits in three geographic areas of Québec were examined as a function of temperature and humidity by using routinely collected May-September data for 1995-2007 (N=347,552 visits). Data for two age groups (under age 65 and age 65 and older) were examined. Incidence rate ratios for mean temperature and humidity were estimated by using Poisson regression and generalized additive models. The number of visits tended to increase with increasing mean temperature. At 22.5 °C (72.5 °F) and 25 °C (77.0 °F), the number was usually significantly higher than average. Visits increased with humidity in the younger age group. Results suggest increased use of emergency departments for mental and psychosocial problems with higher mean temperature and humidity, especially in metropolitan areas and in southern Québec. Climate change may make this effect increasingly important.
Humid Heat Waves at different warming levels
NASA Astrophysics Data System (ADS)
Russo, S.; Sillmann, J.; Sterl, A.
2017-12-01
The co-occurrence of consecutive hot and humid days during a heat wave can strongly affect human health. Here, we quantify humid heat wave hazard in the recent past and at different levels of global warming.We find that the magnitude and apparent temperature peak of heat waves, such as the ones observed in Chicago in 1995 and China in 2003, have been strongly amplified by humidity. Climate model projections suggest that the percentage of area where heat wave magnitude and peak are amplified by humidity increases with increasing warming levels. Considering the effect of humidity at 1.5o and 2o global warming, highly populated regions, such as the Eastern US and China, could experience heat waves with magnitude greater than the one in Russia in 2010 (the most severe of the present era).The apparent temperature peak during such humid-heat waves can be greater than 55o. According to the US Weather Service, at this temperature humans are very likely to suffer from heat strokes. Humid-heat waves with these conditions were never exceeded in the present climate, but are expected to occur every other year at 4o global warming. This calls for respective adaptation measures in some key regions of the world along with international climate change mitigation efforts.
CO{sub 2} adsorption-based separation by metal organic framework (Cu-BTC) versus zeolite (13X)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhijian Liang; Marc Marshall; Alan L. Chaffee
2009-05-15
The potential for the metal organic framework (MOF) Cu-BTC to selectively adsorb and separate CO{sub 2} is considered. Isotherms for CO{sub 2}, CH{sub 4}, and N{sub 2} were measured from 0 to 15 bar and at temperatures between 25 and 105{sup o}C. The isotherms suggest a much higher working capacity (x4) for CO{sub 2} adsorption on Cu-BTC relative to the benchmark zeolite 13X over the same pressure range. Higher CO{sub 2}/N{sub 2} and CO{sub 2}/CH{sub 4} selectivities in the higher pressure range (1-15 bar) and with lower heats of adsorption were also demonstrated. Cu-BTC was observed to be stable inmore » O{sub 2} at 25{sup o}C, but its crystallinity was reduced in humid environments. The CO{sub 2} adsorption capacity was progressively reduced upon cyclic exposure to water vapor at low relative humidity (<30%), but leveled out at 75% of its original value after several water adsorption/desorption cycles. 27 refs., 1 fig.« less
Rosenbaum, Matthew D; VandeWoude, Susan; Volckens, John; Johnson, Thomas E
2010-01-01
Animal room environmental parameters typically are monitored with the assumption that the environment within the cage closely mirrors the room environment. This study evaluated that premise by examining macro- (room) and microenvironmental (cage) parameters in individually ventilated cages housing mice with variable amounts of bedding over a period of 17 d without cage changes. Intracage ammonia levels remained within recommended human guidelines but were higher than room levels, confirming that microisolation caging is efficient at preventing ammonia generated from animal waste from escaping into the room. Humidity and temperature within cages were consistently higher than room levels. Particles in the room predominantly consisted of fine particles (diameter less than 2.5 µm), presumably from the ambient atmosphere; some of these particles were found in the cage microenvironment. In addition, mouse activity within cages produced larger particles, and these particles contributed to substantially higher aerosol mass concentrations within the cage. These findings demonstrate that, although cage and room environmental parameters differ, knowledge of room environmental conditions can be used to predict certain conditions within the cage. This association is relevant in that typical animal care standard operating procedures rely on room measurements, not intracage measurements, which arguably are more important for assessing animal welfare. Further, location and ambient climate can influence particle concentrations in the room, and consequently within the animal cage, suggesting local weather patterns and air quality may account for variability among studies conducted at sites that are geographically divergent. PMID:20353692
Wei, F X; Hu, X F; Xu, B; Zhang, M H; Li, S Y; Sun, Q Y; Lin, P
2015-04-10
To investigate the effect of ammonia (NH3) and humidity on the immune response of broilers, broilers were exposed to 30 or 70 mg/kg atmospheric NH3 for 21 days. Additionally, birds were exposed to 35, 60, and 85% relative humidity (RH). The relative weights of lymphoid organs, serum total protein, serum globulin, serum albumin, serum lysozyme, proliferation index of peripheral blood lymphocytes, and splenic cytokine gene expression were determined. Exposure to 70 mg/kg NH3 decreased the relative weight of the spleen during the experimental period, serum lysozyme concentration in the first and second weeks, and serum globulin concentration in the third week. The proliferation of peripheral blood lymphocytes was reduced. High levels of NH3 caused increase in IL-1β gene expression in the experimental period and IL-4 gene expression in the first week. Birds exposed to 85% RH had lower thymus and bursa of Fabricius weights in the third week and serum lysozyme concentration in the first week; IL-1β and IL-4 expressions were higher in the second and third weeks and first and second weeks, respectively, than in birds exposed to 60% RH. IL-4 expression was lower during the first week, and IL-1β expression was higher during the second week with 35% RH than with 60% RH. In conclusion, high NH3 level in the poultry house suppressed the immune response of broiler chickens. Neither high nor low RH benefited the immune response of broilers. Furthermore, there was an interactive effect between NH3 and RH on the immune response of broilers.
Shibuya, T; Itagaki, K; Ueyama, S; Hirai, N; Endo, R
2016-02-01
We investigated the effects of morphology of host cucumber, Cucumis sativus L., leaves acclimatized to different atmospheric humidity levels on oviposition by adult females of the twospotted spider mite, Tetranychus urticae Koch. Cucumber seedlings were grown at a vapor pressure deficit (VPD) of 0.4, 1.9, or 3.0 kPa at 28°C (90%, 50%, or 20% relative humidity, respectively) in growth chambers until the second true leaves had expanded. Adult females of T. urticae were released on the adaxial surfaces of leaf squares cut from first and second true leaves in each treatment group, and held in the same humidity condition. Eggs were counted 2 d after release. The lower acclimatization humidity (higher VPD) increased trichome (leaf hair) density of the host leaves and oviposition rate, but the relationship between the trichome and oviposition differed between leaf positions. The leaf mass per area (LMA) was greater in first true leaves than in second true leaves, but was not influenced by VPD. A linear regression model with oviposition rate as the dependent variable and trichome density and LMA as independent variables showed that both variables influenced the oviposition rate approximately equally. We conclude that oviposition was accelerated under low humidity (high VPD) conditions indirectly probably through an increase in the trichome density of host leaves. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Effect of Ventilated Caging on Water Intake and Loss in 4 Strains of Laboratory Mice
Nicolaus, Mackenzie L; Bergdall, Valerie K; Davis, Ian C; Hickman-Davis, Judy M
2016-01-01
Food availability, temperature, humidity, strain, and caging type all affect water consumption by mice. Measurement of transepidermal water loss (TEWL) is a new technique for the quantification of water turnover in mice. To understand water turnover in common strains of adult mice, male and female SCID, SKH, C57BL/6, and FVB mice were housed in same-sex groups of 5 animals in static cages or IVC. Body weight, TEWL, urine osmolality, and water consumption of mice and intracage temperature and humidity were measured every 48 h for comparison. Static cages were monitored for 7 d and IVC for 14 d before cage change. Female SCID, FVB, and C57 mice drank less water than did their male counterparts. Male and female SCID, SKH, and FVB mice in IVC drank less water and had higher urine osmolality than did those in static cages. In SCID and SKH mice, TEWL paralleled water consumption. C57 mice in static cages drank less water, had lower urine osmolality, and had less TEWL than did those in IVC. Temperature and humidity within the cage was higher than the macroenvironmental levels for all housing conditions, mouse strains, and sexes. Temperatures within IVC ranged from 76.6 to 81.4 °F compared with 69 ± 0.4 °F in the room. Humidity within IVC ranged from 68% to 79% compared with 27.o% ± 2.7% within the room. These data demonstrate that mouse strain and housing conditions significantly influence water balance and indicate that macroenvironmental measurements do not always reflect the intracage environment. PMID:27657706
Proton transport through aqueous Nafion membrane
NASA Astrophysics Data System (ADS)
Son, D. N.; Kasai, H.
2009-08-01
We introduce a new model for proton transport through a single proton-conducting channel of an aqueous Nafion membrane based on a mechanism in which protons move under electrostatic effect provided by the sulfonate ( SO3 -groups of the Nafion side chains, the spin effect of active components, the hydrogen bonding effect with water molecules, and the screening effect of water media. This model can describe the proton transport within various levels of humidification ranging from the low humidity to the high humidity as a function of operating temperature. At low humidity, this model approaches to the so-called surface mechanism, while at high humidity, it approaches the well-known Grotthuss one. Proton motion is considered as the transfer from cluster to cluster under a potential energy. A proton-proton interaction is comprised in the calculation. Using Green function method, we obtained the proton current as a function of the Nafion membrane temperature. We found that the lower the temperature, the higher the proton current transfer through the Nafion membrane in low temperatures compared to the critical point 10K, which separates magnetic regime from non-magnetic regime. The increasing of proton current at very low temperatures is attributed to the spin effect. As the membrane temperature is higher than 40 ° C , the decreasing of proton current is attributed to the loss of water uptake and the polymer contraction. The results of this study are qualitatively in good agreement with experiments. The expression for the critical temperature is also presented as a function of structural and tunable parameters, and interpreted by experimental data. in here
Hwang, Gi Byoung; Lee, Jung Eun; Nho, Chu Won; Lee, Byung Uk; Lee, Seung Jae; Jung, Jae Hee; Bae, Gwi-Nam
2012-04-01
Bioaerosols have received social and scientific attention because they can be hazardous to human health. Recently, antimicrobial treatments using natural products have been used to improve indoor air quality (IAQ) since they are typically less toxic to humans compared to other antimicrobial substances such as silver, carbon nanotubes, and metal oxides. Few studies, however, have examined how environmental conditions such as the relative humidity (RH), surrounding temperature, and retention time of bacteria on filters affect the filtration and antimicrobial characteristics of a filter treated with such natural products. In this study, we investigated changes in the morphology of the natural nanoparticles, pressure drop, filtration efficiency, and the inactivation rate caused by the short-term effect of humid airflow on antimicrobial fiber filters. Nanoparticles of Sophora flavescens were deposited on the filter media surface using an aerosol process. We observed coalescence and morphological changes of the nanoparticles on fiber filters under humid conditions of an RH >50%. The level of coalescence in these nanoparticles increased with increasing RH. Filters exposed to an RH of 25% have a higher pressure drop than those exposed to an RH >50%. In an inactivation test against Staphylococcus epidermidis bacterial aerosol, the inactivation efficiency at an RH of 25% was higher than that at an RH of 57% or 82%. To effectively apply antimicrobial filters using natural products in the environment, one must characterize the filters under various environmental conditions. Thus, this study provides important information on the use of antimicrobial filters made of natural products. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Chuntao; Zipser, Edward J.
2013-01-01
Both ground and space borne radars have shown that radar reflectivity profiles below the freezing level have different slopes over land and ocean in general. This is critical in correctly estimating the surface precipitation rate in the usual situation in which the radar reflectivity cannot be measured as close to the surface as one would like. Using 14 years of Tropical Rainfall Measuring Mission precipitation radar observations, the variations of slopes of the radar reflectivity in the low troposphere are examined over the stratiform and convective precipitation regions. Radar reflectivity below the freezing level usually decreases toward the surface over land, but increases toward the surface over the ocean. Increasing reflectivity toward the surface is hypothesized to occur mainly when raindrops grow while falling through low clouds, which is favored by high humidity at low levels, and by updraft speeds lower than the fall speed of raindrops, both more likely over oceans. Other things being equal, proxy evidence is presented that the more intense the convection, the more likely reflectivity is to decrease toward the surface, and that this is at least as important as low-level relative humidity. Over monsoon regions with more moderate convection but higher humidity, such as southeast China and the Amazon, there are more profiles with reflectivity increasing toward the surface than over other continental regions such as Africa. Radar reflectivity tends to increase toward the surface in shallow warm rain systems in trade cumulus regions, but tends to decrease toward the surface when high reflectivity values are present at or above the freezing level.
Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures
NASA Technical Reports Server (NTRS)
Nurge, Mark; Youngquist, Robert; Starr, Stanley
2011-01-01
Graphite epoxy composite (GEC) materials are used in the construction of rocket fairings, nose cones, interstage adapters, and heat shields due to their high strength and light weight. However, they absorb moisture depending on the environmental conditions they are exposed to prior to launch. Too much moisture absorption can become a problem when temperature and pressure changes experienced during launch cause the water to vaporize. The rapid state change of the water can result in structural failure of the material. In addition, heat and moisture combine to weaken GEC structures. Diffusion models that predict the total accumulated moisture content based on the environmental conditions are one accepted method of determining if the material strength has been reduced to an unacceptable level. However, there currently doesn t exist any field measurement technique to estimate the actual moisture content of a composite structure. A multi-layer diffusion model was constructed with Mathematica to predict moisture absorption and desorption from the GEC sandwich structure. This model is used in conjunction with relative humidity/temperature sensors both on the inside and outside of the material to determine the moisture levels in the structure. Because the core materials have much higher diffusivity than the face sheets, a single relative humidity measurement will accurately reflect the moisture levels in the core. When combined with an external relative humidity measurement, the model can be used to determine the moisture levels in the face sheets. Since diffusion is temperaturedependent, the temperature measurements are used to determine the diffusivity of the face sheets for the model computations.
Interpolated Sounding and Gridded Sounding Value-Added Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toto, T.; Jensen, M.
Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25more » and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.« less
Nitrogenous compounds changes in emersed oysters: Crassostrea gigas
NASA Astrophysics Data System (ADS)
Rafrafi, Sarra; Uglow, Roger F.
2009-01-01
The effects of emersing oysters ( Crassostrea gigas) for up to 66 h at 4 °C under humid air and nitrogen atmospheres were studied. A significant, gradual body mass loss occurred under nitrogen (8.36 ± 0.85% final weight loss) but no significant loss occurred under humid air (4.92 ± 2.67% final weight loss). Emersion duration and the mantle cavity fluid (MCF) total ammonia (TA) concentration showed a positive, linear relationship ( r2 = 0.73 and 0.74 under humid air and N 2, respectively). The MCF TA and trimethylamine (TMA) contents were also positively related ( r2 = 0.64 and 0.69 under humid air and N 2, respectively). Proline was the most abundant soft tissue free amino acid (71.07 ± 11.8%) in the control group and its concentration did not change significantly under either treatment. The concentration of alanine and valine increased significantly only under humid air. Under N 2, the concentrations of valine and lysine increased significantly and aspartate decreased significantly. Succinate showed a large increase during the first 6 h of emersion under both treatments but significantly more was accumulated in the N 2-exposed group (4.2-fold increase and 8.1-fold increase for the humid air- and N 2-exposed groups, respectively). The succinate concentration difference remained higher in the N 2-treated groups but, in the final 24 h, levels decreased again (quadratic regressions of r2 = 0.97 and 0.95 under humid air and N 2, respectively). Although the trend of succinate accumulation was similar under both treatments, the groups held under nitrogen did not gape (whereas those under humid air did). It is concluded that the implications of gaping behaviour on succinate accumulation in the initial hours of emersion have considerable ecological significance for oysters which occupy habitats in which they may become emersed for some hours naturally. Gaping behaviour also has considerable commercial implications because emersion occurs frequently during the marketing of live oysters.
Gas sensing with gold-decorated vertically aligned carbon nanotubes
Mudimela, Prasantha R; Scardamaglia, Mattia; González-León, Oriol; Reckinger, Nicolas; Snyders, Rony; Llobet, Eduard; Colomer, Jean-François
2014-01-01
Summary Vertically aligned carbon nanotubes of different lengths (150, 300, 500 µm) synthesized by thermal chemical vapor deposition and decorated with gold nanoparticles were investigated as gas sensitive materials for detecting nitrogen dioxide (NO2) at room temperature. Gold nanoparticles of about 6 nm in diameter were sputtered on the top surface of the carbon nanotube forests to enhance the sensitivity to the pollutant gas. We showed that the sensing response to nitrogen dioxide depends on the nanotube length. The optimum was found to be 300 µm for getting the higher response. When the background humidity level was changed from dry to 50% relative humidity, an increase in the response to NO2 was observed for all the sensors, regardless of the nanotube length. PMID:24991529
Gas sensing with gold-decorated vertically aligned carbon nanotubes.
Mudimela, Prasantha R; Scardamaglia, Mattia; González-León, Oriol; Reckinger, Nicolas; Snyders, Rony; Llobet, Eduard; Bittencourt, Carla; Colomer, Jean-François
2014-01-01
Vertically aligned carbon nanotubes of different lengths (150, 300, 500 µm) synthesized by thermal chemical vapor deposition and decorated with gold nanoparticles were investigated as gas sensitive materials for detecting nitrogen dioxide (NO2) at room temperature. Gold nanoparticles of about 6 nm in diameter were sputtered on the top surface of the carbon nanotube forests to enhance the sensitivity to the pollutant gas. We showed that the sensing response to nitrogen dioxide depends on the nanotube length. The optimum was found to be 300 µm for getting the higher response. When the background humidity level was changed from dry to 50% relative humidity, an increase in the response to NO2 was observed for all the sensors, regardless of the nanotube length.
The performance of hematite nanostructures in different humidity levels
NASA Astrophysics Data System (ADS)
Ahmad, W. R. W.; Mamat, M. H.; Zoolfakar, A. S.; Khusaimi, Z.; Yusof, M. M.; Ismail, A. S.; Saidi, S. A.; Rusop, M.
2018-05-01
In this study, hematite (α-Fe2O3) nanostructure were prepared in Schott vials on fluorine-doped tin oxide (FTO) coated glass substrate using the sonicated immersion method in aqueous solution with ferric chloride FeCl3ṡ6H2O as a precursor and urea NH2-CONH2 as a stabilizer. The samples were characterized for different level of humidity conditions within range 40% to 90% RH. Based on the results obtained, the hematite nanostructure exhibited good optical properties and virtuous sensor response with high sensitivity. The fabricated hematite nanostructure has revealed a good potential for humidity sensor application based on the results obtained under different levels of humidity.
Reversible adhesion switching of porous fibrillar adhesive pads by humidity.
Xue, Longjian; Kovalev, Alexander; Dening, Kirstin; Eichler-Volf, Anna; Eickmeier, Henning; Haase, Markus; Enke, Dirk; Steinhart, Martin; Gorb, Stanislav N
2013-01-01
We report reversible adhesion switching on porous fibrillar polystyrene-block-poly(2-vinyl pyridine) (PS-b-P2VP) adhesive pads by humidity changes. Adhesion at a relative humidity of 90% was more than nine times higher than at a relative humidity of 2%. On nonporous fibrillar adhesive pads of the same material, adhesion increased only by a factor of ~3.3. The switching performance remained unchanged in at least 10 successive high/low humidity cycles. Main origin of enhanced adhesion at high humidity is the humidity-induced decrease in the elastic modulus of the polar component P2VP rather than capillary force. The presence of spongelike continuous internal pore systems with walls consisting of P2VP significantly leveraged this effect. Fibrillar adhesive pads on which adhesion is switchable by humidity changes may be used for preconcentration of airborne particulates, pollutants, and germs combined with triggered surface cleaning.
Fabrication and Characterization of a CMOS-MEMS Humidity Sensor.
Dennis, John-Ojur; Ahmed, Abdelaziz-Yousif; Khir, Mohd-Haris
2015-07-10
This paper reports on the fabrication and characterization of a Complementary Metal Oxide Semiconductor-Microelectromechanical System (CMOS-MEMS) device with embedded microheater operated at relatively elevated temperatures (40 °C to 80 °C) for the purpose of relative humidity measurement. The sensing principle is based on the change in amplitude of the device due to adsorption or desorption of humidity on the active material layer of titanium dioxide (TiO2) nanoparticles deposited on the moving plate, which results in changes in the mass of the device. The sensor has been designed and fabricated through a standard 0.35 µm CMOS process technology and post-CMOS micromachining technique has been successfully implemented to release the MEMS structures. The sensor is operated in the dynamic mode using electrothermal actuation and the output signal measured using a piezoresistive (PZR) sensor connected in a Wheatstone bridge circuit. The output voltage of the humidity sensor increases from 0.585 mV to 30.580 mV as the humidity increases from 35% RH to 95% RH. The output voltage is found to be linear from 0.585 mV to 3.250 mV as the humidity increased from 35% RH to 60% RH, with sensitivity of 0.107 mV/% RH; and again linear from 3.250 mV to 30.580 mV as the humidity level increases from 60% RH to 95% RH, with higher sensitivity of 0.781 mV/% RH. On the other hand, the sensitivity of the humidity sensor increases linearly from 0.102 mV/% RH to 0.501 mV/% RH with increase in the temperature from 40 °C to 80 °C and a maximum hysteresis of 0.87% RH is found at a relative humidity of 80%. The sensitivity is also frequency dependent, increasing from 0.500 mV/% RH at 2 Hz to reach a maximum value of 1.634 mV/% RH at a frequency of 12 Hz, then decreasing to 1.110 mV/% RH at a frequency of 20 Hz. Finally, the CMOS-MEMS humidity sensor showed comparable response, recovery, and repeatability of measurements in three cycles as compared to a standard sensor that directly measures humidity in % RH.
Fabrication and Characterization of a CMOS-MEMS Humidity Sensor
Dennis, John-Ojur; Ahmed, Abdelaziz-Yousif; Khir, Mohd-Haris
2015-01-01
This paper reports on the fabrication and characterization of a Complementary Metal Oxide Semiconductor-Microelectromechanical System (CMOS-MEMS) device with embedded microheater operated at relatively elevated temperatures (40 °C to 80 °C) for the purpose of relative humidity measurement. The sensing principle is based on the change in amplitude of the device due to adsorption or desorption of humidity on the active material layer of titanium dioxide (TiO2) nanoparticles deposited on the moving plate, which results in changes in the mass of the device. The sensor has been designed and fabricated through a standard 0.35 µm CMOS process technology and post-CMOS micromachining technique has been successfully implemented to release the MEMS structures. The sensor is operated in the dynamic mode using electrothermal actuation and the output signal measured using a piezoresistive (PZR) sensor connected in a Wheatstone bridge circuit. The output voltage of the humidity sensor increases from 0.585 mV to 30.580 mV as the humidity increases from 35% RH to 95% RH. The output voltage is found to be linear from 0.585 mV to 3.250 mV as the humidity increased from 35% RH to 60% RH, with sensitivity of 0.107 mV/% RH; and again linear from 3.250 mV to 30.580 mV as the humidity level increases from 60% RH to 95% RH, with higher sensitivity of 0.781 mV/% RH. On the other hand, the sensitivity of the humidity sensor increases linearly from 0.102 mV/% RH to 0.501 mV/% RH with increase in the temperature from 40 °C to 80 °C and a maximum hysteresis of 0.87% RH is found at a relative humidity of 80%. The sensitivity is also frequency dependent, increasing from 0.500 mV/% RH at 2 Hz to reach a maximum value of 1.634 mV/% RH at a frequency of 12 Hz, then decreasing to 1.110 mV/% RH at a frequency of 20 Hz. Finally, the CMOS-MEMS humidity sensor showed comparable response, recovery, and repeatability of measurements in three cycles as compared to a standard sensor that directly measures humidity in % RH. PMID:26184204
Study on water evaporation rate from indoor swimming pools
NASA Astrophysics Data System (ADS)
Rzeźnik, Ilona
2017-11-01
The air relative humidity in closed spaces of indoor swimming pools influences significantly on users thermal comfort and the stability of the building structure, so its preservation on suitable level is very important. For this purpose, buildings are equipped with HVAC systems which provide adequate level of humidity. The selection of devices and their technical parameters is made using the mathematical models of water evaporation rate in the unoccupied and occupied indoor swimming pool. In the literature, there are many papers describing this phenomena but the results differ from each other. The aim of the study was the experimental verification of published models of evaporation rate in the pool. The tests carried out on a laboratory scale, using model of indoor swimming pool, measuring 99cm/68cm/22cm. The model was equipped with water spray installation with six nozzles to simulate conditions during the use of the swimming pool. The measurements were made for conditions of sports pools (water temperature 24°C) and recreational swimming pool (water temperature 34°C). According to the recommendations the air temperature was about 2°C higher than water temperature, and the relative humidity ranged from 40% to 55%. Models Shah and Biasin & Krumm were characterized by the best fit to the results of measurements on a laboratory scale.
Kim, Jae Yong; Kim, Myoung Joon; Lim, Byeong Gak
2016-01-01
Purpose. To assess the effect of three-dimensional (3D) printed personalized moisture chamber spectacles (PMCS) on the periocular humidity. Methods. Facial computed tomography (CT) scanning was conducted on 10 normal subjects. PMCS was designed based on volume rendered CT images and produced using a 3D printer. Periocular humidity of PMCS and commercially available uniformed moisture chamber spectacles (UMCS) were measured for 30 minutes via microhydrometer. Results. The mean ambient humidity was 15.76 ± 1.18%. The mean periocular humidity was 52.14 ± 3.00% in PMCS and 37.67 ± 8.97% in UMCS. The difference was significant (P < 0.001). Additionally, PMCS always demonstrated lower humidity than dew points. Conclusion. PMCS made by 3D printer provides appropriate fitness for the semiclosed humid chamber. PMCS showed higher performance than UMCS. The wearing of PMCS would be an effective method to provide high enough periocular humidity in low humidity environment. PMID:27843644
Impact of air-drying lens cases in various locations and positions.
Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona
2010-07-01
To determine the rate and type of microbial contamination when contact lens cases are air-dried in two different positions (face up and face down) and in four different locations (toilet, bathroom, office, and bedroom). Unused contact lens cases (n = 97) were rinsed with 2-ml sterile phosphate buffered saline and then placed on facial tissue paper in different locations: humid (toilet and bathroom) and non-humid (office and bedroom) and air-dried at room temperature. After 24 h, the contact lens cases were collected and sampled for microbial numbers and microbial types identified using standard techniques. The microbial profile and the rate of contamination between different locations and positions were compared. Irrespective of the air-drying location, contact lens cases positioned face up had a significantly higher contamination rate (34/48, 71%) compared with contact lens cases air-dried face down (6/49, 12%) (p < 0.001). For those contact lens cases air-dried face up, there was more contamination when placed in humid environments (toilet and bathroom) than in the non-humid environments (office and bedroom) (p = 0.01). However, the contact lens case contamination rate among various locations was similar when contact lens cases were air-dried face down. Total microorganisms recovered from contact lens cases ranged from 0 to 275 colony forming unit per well. The most frequently recovered microorganisms from the contaminated contact lens cases were coagulase-negative Staphylococci, fungi, and Bacillus spp. Thirty-three percent (13/40) of contact lens cases were contaminated with multiple species. Small numbers of microorganisms from the environment may contaminate contact lens cases while cases are air-dried face up. Cases air-dried in humid environments have higher levels of microbial contamination; this is particularly true when contact lens cases are positioned face up. On the basis of this limited study, we would recommend contact lens cases be air-dried face down.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arundel, A.V.; Sterling, E.M.; Biggin, J.H.
A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versusmore » low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens.« less
Bicalho, Gustavo P; Braz, Leandro G; de Jesus, Larissa S B; Pedigone, Cesar M C; de Carvalho, Lídia R; Módolo, Norma S P; Braz, José R C
2014-10-01
An inhaled gas absolute humidity of 20 mg H2O·L is the value most considered as the threshold necessary for preventing the deleterious effects of dry gas on the epithelium of the airways during anesthesia. Because children have small minute ventilation, we hypothesized that the humidification of a circle breathing system is lower in children compared with adults. The Primus anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat the patient's exhaled gases. A heat and moisture exchanger (HME) is a device that can be used to further humidify and heat the inhaled gases during anesthesia. To evaluate the humidifying properties of this circle breathing system during pediatric anesthesia, we compared the temperature and humidity of inhaled gases under low or high fresh gas flow (FGF) conditions and with or without an HME. Forty children were randomly allocated into 4 groups according to the ventilation of their lungs by a circle breathing system in a Dräger Primus anesthesia workstation with low (1 L·min) or high (3 L·min) FGF without an HME (1L and 3L groups) or with an HME (Pall BB25FS, Pall Biomedical, East Hills, NY; HME1L and HME3L groups). The temperature and absolute humidity of inhaled gases were measured at 10, 20, 40, 60, and 80 minutes after connecting the patient to the breathing circuit. The mean inhaled gas temperature was higher in HME groups (HME1L: 30.3°C ± 1.1°C; HME3L: 29.3°C ± 1.2°C) compared with no-HME groups (1L: 27.0°C ± 1.2°C; 3L: 27.1°C ± 1.5°C; P < 0.0001). The mean inhaled gas absolute humidity was higher in HME than no-HME groups and higher in low-flow than high-flow groups ([HME1L: 25 ± 1 mg H2O·L] > [HME3L: 23 ± 2 mg H2O·L] > [1L: 17 ± 1 mg H2O·L] > [3L: 14 ± 1 mg H2O·L]; P < 0.0001). In a pediatric circle breathing system, the use of neither high nor low FGF provides the minimum humidity level of the inhaled gases thought to reduce the risk of dehydration of airways. Insertion of an HME increases the humidity and temperature of the inhaled gases, bringing them closer to physiological values. The use of a low FGF enhances the HME efficiency and consequently increases the inhaled gas humidity values. Therefore, the association of an HME with low FGF in the breathing circuit is the most efficient way to conserve the heat and the moisture of the inhaled gas during pediatric anesthesia.
Sellin, Arne; Niglas, Aigar; Õunapuu-Pikas, Eele; Kupper, Priit
2014-03-24
Effects of water deficit on plant water status, gas exchange and hydraulic conductance were investigated in Betula pendula under artificially manipulated air humidity in Eastern Estonia. The study was aimed to broaden an understanding of the ability of trees to acclimate with the increasing atmospheric humidity predicted for northern Europe. Rapidly-induced water deficit was imposed by dehydrating cut branches in open-air conditions; long-term water deficit was generated by seasonal drought. The rapid water deficit quantified by leaf (ΨL) and branch water potentials (ΨB) had a significant (P < 0.001) effect on gas exchange parameters, while inclusion of ΨB in models resulted in a considerably better fit than those including ΨL, which supports the idea that stomatal openness is regulated to prevent stem rather than leaf xylem dysfunction. Under moderate water deficit (ΨL≥-1.55 MPa), leaf conductance to water vapour (gL), transpiration rate and leaf hydraulic conductance (KL) were higher (P < 0.05) and leaf temperature lower in trees grown in elevated air humidity (H treatment) than in control trees (C treatment). Under severe water deficit (ΨL<-1.55 MPa), the treatments showed no difference. The humidification manipulation influenced most of the studied characteristics, while the effect was to a great extent realized through changes in soil water availability, i.e. due to higher soil water potential in H treatment. Two functional characteristics (gL, KL) exhibited higher (P < 0.05) sensitivity to water deficit in trees grown under increased air humidity. The experiment supported the hypothesis that physiological traits in trees acclimated to higher air humidity exhibit higher sensitivity to rapid water deficit with respect to two characteristics - leaf conductance to water vapour and leaf hydraulic conductance. Disproportionate changes in sensitivity of stomatal versus leaf hydraulic conductance to water deficit will impose greater risk of desiccation-induced hydraulic dysfunction on the plants, grown under high atmospheric humidity, in case of sudden weather fluctuations, and might represent a potential threat in hemiboreal forest ecosystems. There is no trade-off between plant hydraulic capacity and photosynthetic water-use efficiency on short time scale.
Indirect health effects of relative humidity in indoor environments.
Arundel, A V; Sterling, E M; Biggin, J H; Sterling, T D
1986-01-01
A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versus low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens. PMID:3709462
Effects of humidity and interlayer cations on the frictional strength of montmorillonite
NASA Astrophysics Data System (ADS)
Tetsuka, Hiroshi; Katayama, Ikuo; Sakuma, Hiroshi; Tamura, Kenji
2018-04-01
We developed a humidity control system in a biaxial friction testing machine to investigate the effect of relative humidity and interlayer cations on the frictional strength of montmorillonite. We carried out the frictional experiments on Na- and Ca-montmorillonite under controlled relative humidities (ca. 10, 30, 50, 70, and 90%) and at a constant temperature (95 °C). Our experimental results show that frictional strengths of both Na- and Ca-montmorillonite decrease systematically with increasing relative humidity. The friction coefficients of Na-montmorillonite decrease from 0.33 (at relative humidity of 10%) to 0.06 (at relative humidity of 93%) and those of Ca-montmorillonite decrease from 0.22 (at relative humidity of 11%) to 0.04 (at relative humidity of 91%). Our results also show that the frictional strength of Na-montmorillonite is higher than that of Ca-montmorillonite at a given relative humidity. These results reveal that the frictional strength of montmorillonite is sensitive to hydration state and interlayer cation species, suggesting that the strength of faults containing these clay minerals depends on the physical and chemical environment.[Figure not available: see fulltext.
Biosimilarity under stress: A forced degradation study of Remicade® and Remsima™.
Pisupati, Karthik; Benet, Alexander; Tian, Yuwei; Okbazghi, Solomon; Kang, Jukyung; Ford, Michael; Saveliev, Sergei; Sen, K Ilker; Carlson, Eric; Tolbert, Thomas J; Ruotolo, Brandon T; Schwendeman, Steven P; Schwendeman, Anna
2017-10-01
Remsima™ (infliximab) is the first biosimilar monoclonal antibody (mAb) approved by the European Medical Agency and the US Food and Drug Administration. Remsima™ is highly similar to its reference product, Remicade®, with identical formulation components. The 2 products, however, are not identical; Remsima™ has higher levels of soluble aggregates, C-terminal lysine truncation, and fucosylated glycans. To understand if these attribute differences could be amplified during forced degradation, solutions and lyophilized powders of the 2 products were subjected to stress at elevated temperature (40-60°C) and humidity (dry-97% relative humidity). Stress-induced aggregation and degradation profiles were similar for the 2 products and resulted in loss of infliximab binding to tumor necrosis factor and FcγRIIIa. Appearances of protein aggregates and hydrolysis products were time- and humidity-dependent, with similar degradation rates observed for the reference and biosimilar products. Protein powder incubations at 40°C/97% relative humidity resulted in partial mAb unfolding and increased asparagine deamidation. Minor differences in heat capacity, fluorescence, levels of subvisible particulates, deamidation and protein fragments were observed in the 2 stressed products, but these differences were not statistically significant. The protein solution instability at 60°C, although quite significant, was also similar for both products. Despite the small initial analytical differences, Remicade® and Remsima™ displayed similar degradation mechanisms and kinetics. Thus, our results show that the 2 products are highly similar and infliximab's primary sequence largely defines their protein instabilities compared with the limited influence of small initial purity and glycosylation differences in the 2 products.
NASA Astrophysics Data System (ADS)
Ohta, Hiromi; Maruyama, Megumi; Tanabe, Yoko; Hara, Toshiko; Nishino, Yoshihiko; Tsujino, Yoshio; Morita, Eishin; Kobayashi, Shotai; Shido, Osamu
2008-05-01
We investigated the effects of redecoration of a hospital isolation room with natural materials on thermoregulatory, cardiovascular and hormonal parameters of healthy subjects staying in the room. Two isolation rooms with almost bilaterally-symmetrical arrangements were used. One room (RD) was redecorated with wood paneling and Japanese paper, while the other (CN) was unchanged (with concrete walls). Seven healthy male subjects stayed in each room for over 24 h in the cold season. Their rectal temperature (Tre) and heart rate, and the room temperature (Ta) and relative humidity were continuously measured. Arterial blood pressures, arterial vascular compliance, thermal sensation and thermal comfort were measured every 4 h except during sleeping. Blood was sampled after the stay in the rooms. In RD, Ta was significantly higher by about 0.4°C and relative humidity was lower by about 5% than in CN. Diurnal Tre levels of subjects in RD significantly differed from those in CN, i.e., Tres were significantly higher in RD than in CN especially in the evening. In RD, the subjects felt more thermally-comfortable than in CN. Redecoration had minimal effects on cardiovascular parameters. Plasma levels of catecholamines and antidiuretic hormone did not differ, while plasma cortisol level was significantly lower after staying in RD than in CN by nearly 20%. The results indicate that, in the cold season, redecoration with natural materials improves the thermal environment of the room and contributes to maintaining core temperature of denizens at preferable levels. It also seems that redecoration of room could attenuate stress levels of isolated subjects.
Gauslaa, Yngvar; Coxson, Darwyn S; Solhaug, Knut Asbjørn
2012-01-01
Desiccation tolerance was quantified in four cyanolichens (Lobaria hallii, Lobaria retigera, Lobaria scrobiculata, Pseudocyphellaria anomala), one cephalolichen (Lobaria pulmonaria) and one chlorolichen (Platismatia glauca) from xeric and mesic, open and closed North American boreal forests. These sympatric epiphytes were exposed to 0%, 33%, 55% and 75% relative humidity with or without medium light (200 μmol m−2 s−1) for 7 d. Permanent and temporary photoinhibitory damage was recorded as viability measures. All species tolerated well the drying in darkness, but L. hallii and L. retigera, associated with a very humid climate, showed minor damage at the hardest drying (silica gel). Simultaneous exposure to medium light severely aggravated the drying damage at all relative humidity levels. Combined drying–light exposure was particularly devastating for the widespread chloro- and cephalolichens, whereas cyanolichens, including rare old forest species, were fairly resistant. The ability to recover after combined drying–light stress (this study) correlated positively with increasing species-specific water holding capacities (from the literature). Cyanolichens, depending on liquid water and large internal water storage, probably require strong drying–light resistance to handle long periods between hydration events, whereas chlorolichens can regularly maintain their photosynthetic apparatus during frequent and rapid activation by humid air on clear mornings. PMID:22762452
Evaluate humidity sensing properties of novel TiO{sub 2}–WO{sub 3} composite material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Wang-De; Department of Center for General Education, St. Mary's Junior College of Medicine, Nursing and Management, Yilan 26644 Taiwan, ROC; Lai, De-Sheng
2013-10-15
Graphical abstract: TiO{sub 2}–WO{sub 3} (1:1) showed better humidity sensing properties than others within the range of 12–90% relative humidity (RH), the response and recovery time were about 20 s and 160 s, respectively. Compared to the previous studies, the prepared sensor exhibits higher sensitivity (S = 451) and the low hysteresis value was around 0.13% at 32% RH. - Highlights: • Novel TiO{sub 2}–WO{sub 3} composite material was prepared for humidity sensor. • The sensor exhibits higher sensitivity (S = 451). • Low hysteresis value was around 0.13% at 32% RH. - Abstract: A novel TiO{sub 2}–WO{sub 3} compositemore » material was prepared using a different proportion of TiO{sub 2} and WO{sub 3} to that investigated in previous studies. The obtained mesoporous material was characterized using X-ray diffraction, Fourier transform infrared spectrometry, transmission electron microscopy, energy dispersive X-ray spectroscopy, and N{sub 2} adsorption-desorption techniques. The humidity-sensing properties were measured using an inductance, capacitance and resistance analyzer. The results demonstrated that the TiO{sub 2}–WO{sub 3} sample with a ratio of 1:1 showed better humidity sensing properties. Compared to previous studies, the prepared sensor exhibited higher sensitivity (S = 451) and the lower hysteresis value was around 0.13% at 32% RH. Complex impedance analysis indicated that the enhanced humidity sensitivity was probably due to spherical Brunauer–Emmett–Teller surface area and the hetero-junction between TiO{sub 2}–WO{sub 3} thin films, while the impedance varied about three orders of magnitude. Our results demonstrated the potential application of TiO{sub 2}–WO{sub 3} composite for fabricating high performance humidity sensors.« less
Relation of Temperature and Humidity to the Risk of Recurrent Gout Attacks
Neogi, Tuhina; Chen, Clara; Niu, Jingbo; Chaisson, Christine; Hunter, David J.; Choi, Hyon; Zhang, Yuqing
2014-01-01
Gout attack risk may be affected by weather (e.g., because of volume depletion). We therefore examined the association of temperature and humidity with the risk of recurrent gout attacks by conducting an internet-based case-crossover study in the United States (in 2003–2010) among subjects with a diagnosis of gout who had 1 or more attacks during 1 year of follow-up. We examined the association of temperature and humidity over the prior 48 hours with the risk of gout attacks using a time-stratified approach and conditional logistic regression. Among 632 subjects with gout, there was a significant dose-response relationship between mean temperature in the prior 48 hours and the risk of subsequent gout attack (P = 0.01 for linear trend). Higher temperatures were associated with approximately 40% higher risk of gout attack compared with moderate temperatures. There was a reverse J-shaped relationship between mean relative humidity and the risk of gout attacks (P = 0.03 for quadratic trend). The combination of high temperature and low humidity had the greatest association (odds ratio = 2.04, 95% confidence interval: 1.26, 3.30) compared with moderate temperature and relative humidity. Thus, high ambient temperature and possibly extremes of humidity were associated with an increased risk of gout attack, despite the likelihood that individuals are often in climate-controlled indoor environments. PMID:24993733
NASA Astrophysics Data System (ADS)
Oliveira, M.; Ribeiro, H.; Delgado, J. L.; Abreu, I.
2009-01-01
Although fungal spores are an ever-present component of the atmosphere throughout the year, their concentration oscillates widely. This work aims to establish correlations between fungal spore concentrations in Porto and Amares and meteorological data. The seasonal distribution of fungal spores was studied continuously (2005-2007) using volumetric spore traps. To determine the effect of meteorological factors (temperature, relative humidity and rainfall) on spore concentration, the Spearman rank correlation test was used. In both locations, the most abundant fungal spores were Cladosporium, Agaricus, Agrocybe, Alternaria and Aspergillus/Penicillium, the highest concentrations being found during summer and autumn. In the present study, with the exception of Coprinus and Pleospora, spore concentrations were higher in the rural area than in the urban location. Among the selected spore types, spring-autumn spores ( Coprinus, Didymella, Leptosphaeria and Pleospora) exhibited negative correlations with temperature and positive correlations both with relative humidity and rainfall level. On the contrary, late spring-early summer (Smuts) and summer spores ( Alternaria, Cladosporium, Epicoccum, Ganoderma, Stemphylium and Ustilago) exhibited positive correlations with temperature and negative correlations both with relative humidity and rainfall level. Rust, a frequent spore type during summer, had a positive correlation with temperature. Aspergillus/Penicillium, showed no correlation with the meteorological factors analysed. This knowledge can be useful for agriculture, allowing more efficient and reliable application of pesticides, and for human health, by improving the diagnosis and treatment of respiratory allergic disease.
The effect of environmental parameters to dust concentration in air-conditioned space
NASA Astrophysics Data System (ADS)
Ismail, A. M. M.; Manssor, N. A. S.; Nalisa, A.; Yahaya, N.
2017-08-01
Malaysia has a wet and hot climate, therefore most of the spaces are air conditioned. The environment might affect dust concentration inside a space and affect the indoor air quality (IAQ). The main objective of this study is to study the dust concentration collected inside enclosed air-conditioned space. The measurement was done physically at four selected offices and two classrooms using a number of equipment to measure the dust concentration and environmental parameters which are temperature and relative air humidity. It was found that the highest dust concentration produced in office (temperature of 24.7°C, relative humidity of 66.5%) is 0.075 mg/m3, as compared to classroom, the highest dust concentration produced is 0.060 mg/m3 office (temperature of 25.9°C, relative humidity of 64.0%). However, both measurements show that value still within the safety level set by DOSH Malaysia (2005-2010) and ASHRAE 62.2 2016. The office contained higher dust concentration compared to classroom because of frequent movement transpires daily due to the functional of the offices.
Valero, Miguel Ángel; Merello, Paloma; Navajas, Ángel Fernández; García-Diego, Fernando-Juan
2014-01-01
The Noheda archaeological site is unique and exceptional for its size, and the quality and conservation condition of the Roman mosaic pavement covering its urban pars. In 2008 a tent was installed as protection from rain and sun. Being of interest to characterise the microclimate of the remains, six probes with relative humidity and temperature sensors were installed in 2013 for this purpose. Microclimate monitoring allowed us to check relative humidity differences resulting from the groundwater level, as well as inner sensors reaching maximum temperatures higher than the outdoors ones as a consequence of the non-ventilated tent covering the archaeological site. Microclimatic conditions in the archaeological site were deemed detrimental for the conservation of the mosaics. Thus, in summer 2013, expanded clay and geotextile were installed over the mosaics as a corrective action. The outcomes of this study have proven the effectiveness of this solution to control temperature and relative humidity, helping to configure a more stable microclimate suitable for preservation of the mosaic. PMID:24445414
Valero, Miguel Ángel; Merello, Paloma; Navajas, Ángel Fernández; García-Diego, Fernando-Juan
2014-01-17
The Noheda archaeological site is unique and exceptional for its size, and the quality and conservation condition of the Roman mosaic pavement covering its urban pars. In 2008 a tent was installed as protection from rain and sun. Being of interest to characterise the microclimate of the remains, six probes with relative humidity and temperature sensors were installed in 2013 for this purpose. Microclimate monitoring allowed us to check relative humidity differences resulting from the groundwater level, as well as inner sensors reaching maximum temperatures higher than the outdoors ones as a consequence of the non-ventilated tent covering the archaeological site. Microclimatic conditions in the archaeological site were deemed detrimental for the conservation of the mosaics. Thus, in summer 2013, expanded clay and geotextile were installed over the mosaics as a corrective action. The outcomes of this study have proven the effectiveness of this solution to control temperature and relative humidity, helping to configure a more stable microclimate suitable for preservation of the mosaic.
Humidity profiles over the ocean
NASA Technical Reports Server (NTRS)
Liu, W. T.; Tang, Wenqing; Niiler, Pearn P.
1991-01-01
The variabilities of atmospheric humidity profile over oceans from daily to interannual time scales were examined using 9 years of daily and semidaily radiosonde soundings at island stations extending from the Arctic to the South Pacific. The relative humidity profiles were found to have considerable temporal and geographic variabilities, contrary to the prevalent assumption. Principal component analysis on the profiles of specific humidity were used to examine the applicability of a relation between the surface-level humidity and the integrated water vapor; this relation has been used to estimate large-scale evaporation from satellite data. The first principal component was found to correlate almost perfectly with the integrated water vapor. The fractional variance represented by this mode increases with increasing period. It reaches approximately 90 percent at two weeks and decreases sharply, below one week, down to approximately 60 percent at the daily period. At low frequencies, the integrated water vapor appeared to be an adequate estimator of the humidity profile and the surface-level humidity. At periods shorter than a week, more than one independent estimator is needed.
Electrolyte changes in the blood plasma of broilers as influenced by cooling during summer
NASA Astrophysics Data System (ADS)
Sharma, M. L.; Gangwar, P. C.
1987-09-01
High temperature significantly (P < 0.01) decreased the Na+ and K+ concentrations in the blood plasma of both the sexes of broilers during 4 to 8 weeks of age. Relatively constant levels of these electrolytes were observed during this phase of growth and the sex of the bird had no significant effect on their levels. Greater broiler weights and higher levels of plasma electrolyte were achieved by the use of cooling systems (which were more effective in the hot dry part of the summer than in the hot humid part).
Lidar Measurements of Relative Humidity and Ice Supersaturation in the Upper Troposphere
NASA Technical Reports Server (NTRS)
Ferrare, Richard A.; Browell, Edward V.; Ismail, Syed; Brackett, Vincent G.; Clayton, Marian B.; Fenn, Marta; Heilman, Lorraine; Kooi, Susan A.; Turner, David D.; Mahoney, Michael J.
2000-01-01
We compute upper tropospheric relative humidity profiles using water vapor profiles measured by an airborne DIAL and a ground-based Raman lidar. LASE water vapor and MTP temperature profiles acquired from the NASA DC-8 aircraft during the recent Pacific Exploratory Mission Tropics B (PEM Tropics B) field mission in the tropical Pacific and the SAGE-III Ozone Loss and Validation Experiment (SOLVE) in the Arctic as well as water vapor profiles derived from the ground-based DOE ARM Southern Great Plains (SGP) CART Raman lidar are used. Comparisons of the lidar water vapor measurements with available in situ measurements show reasonable agreement for water vapor mixing ratios above 0.05 g/kg. Relative humidity frequency distributions computed using LASE data indicate that ice supersaturation occurred about 5-11% of the time when temperatures were below -35 C. While a higher frequency of ice supersaturation was observed during SOLVE, higher peak values of relative humidity were observed during PEM Tropics B. The relative humidity fields associated with cirrus clouds are also examined.
Zhang, Na; Xu, Wen Xiu; Li, Lan Hai; Wu, Ni Ping; Wu, Pei Jie; Cheng, Xue Feng
2016-08-01
To optimize the fertilization rate of winter wheat under drip irrigation in Xinjiang region, a field investigation was carried out to assess effects of nitrogen (N) applications on canopy vertical structure, grain-leaf ratio, yield and economic benefit of winter wheat. Four rates of nitrogen application, 0 kg·hm -2 (N 0 ), 104 kg·hm -2 (N 1 ), 173 kg·hm -2 (N 2 ) and 242 kg·hm -2 (N 3 ) were set in a randomized block experimental design. Meantime, leaf and stem morphological characters, canopy temperature and humidity in flowering stage, grain-leaf area ratio, yield and yield components, economic benefits of winter wheat were observed under different treatments. The results showed that the leaf length and width at different positions of wheat under the nitrogen fertilization treatments were significantly higher than that without nitrogen fertilization (P<0.05), and plant height ranged from 65.57 to 81.58 cm. With an increasing rate of nitrogen fertilization, both leafarea index and stem diameter presented a trend of first increasing and then decreasing, and reached the maximum under N 2 treatment, which was 5.48 and 0.49 cm, respectively. Diurnal variation of canopy temperature and humidity were "convex" and "concave" shape, followed an order of N 0 >N 1 >N 2 >N 3 in temperature, but reversely in canopy humidity. The duration of high temperature higher than 35 ℃ were shorten 1 hour to 3.5 hours as the nitrogen application level increased, and there was significant difference between N 1 and N 3 on grain-leaf ratio. Yield and economic be-nefit decreased initially and then increased with increasing nitrogen application. Yield and economic benefit of treatment N 2 were 32.8% and 77.7% higher than those of treatment N 0 , 12.6% and 5.4% higher than those of treatment N 1 , and 5.2% and 4.2% higher than those of treatment N 3 , respectively. These results indicated that nitrogen application at about 173 kg·hm -2 could be recommended as the optimum rate for winter wheat, which had good leaf and plant morphology, appropriate canopy temperature and humidity, high yield and economic efficiency in the experiment area.
Proximate composition of CELSS crops grown in NASA's Biomass Production Chamber.
Wheeler, R M; Mackowiak, C L; Sager, J C; Knott, W M; Berry, W L
1996-01-01
Edible biomass from four crops of wheat (Triticum aestivum L.), four crops of lettuce (Lactuca sativa L.), four crops of potato (Solanum tuberosum L.), and three crops of soybean (Glycine max (L.) Merr.) grown in NASA's CELSS Biomass Production Chamber were analyzed for proximate composition. All plants were grown using recirculating nutrient (hydroponic) film culture with pH and electrical conductivity automatically controlled. Temperature and humidity were controlled to near optimal levels for each species and atmospheric carbon dioxide partial pressures were maintained near 100 Pa during the light cycles. Soybean seed contained the highest percentage of protein and fat, potato tubers and wheat seed contained the highest levels of carbohydrate, and lettuce leaves contained the highest level of ash. Analyses showed values close to data published for field-grown plants with several exceptions: In comparison with field-grown plants, wheat seed had higher protein levels; soybean seed had higher ash and crude fiber levels; and potato tubers and lettuce leaves had higher protein and ash levels. The higher ash and protein levels may have been a result of the continuous supply of nutrients (e.g., potassium and nitrogen) to the plants by the recirculating hydroponic culture.
Proximate composition of CELSS crops grown in NASA's Biomass Production Chamber
NASA Technical Reports Server (NTRS)
Wheeler, R. M.; Mackowiak, C. L.; Sager, J. C.; Knott, W. M.; Berry, W. L.
1996-01-01
Edible biomass from four crops of wheat (Triticum aestivum L.), four crops of lettuce (Lactuca sativa L.), four crops of potato (Solanum tuberosum L.), and three crops of soybean (Glycine max (L.) Merr.) grown in NASA's CELSS Biomass Production Chamber were analyzed for proximate composition. All plants were grown using recirculating nutrient (hydroponic) film culture with pH and electrical conductivity automatically controlled. Temperature and humidity were controlled to near optimal levels for each species and atmospheric carbon dioxide partial pressures were maintained near 100 Pa during the light cycles. Soybean seed contained the highest percentage of protein and fat, potato tubers and wheat seed contained the highest levels of carbohydrate, and lettuce leaves contained the highest level of ash. Analyses showed values close to data published for field-grown plants with several exceptions: In comparison with field-grown plants, wheat seed had higher protein levels; soybean seed had higher ash and crude fiber levels; and potato tubers and lettuce leaves had higher protein and ash levels. The higher ash and protein levels may have been a result of the continuous supply of nutrients (e.g., potassium and nitrogen) to the plants by the recirculating hydroponic culture.
Proximate composition of CELSS crops grown in NASA's Biomass Production Chamber
NASA Astrophysics Data System (ADS)
Wheeler, R. M.; Mackowiak, C. L.; Sager, J. C.; Knott, W. M.; Berry, W. L.
Edible biomass from four crops of wheat (Triticum aestivum L.), four crops of lettuce (Lactuca sativa L.), four crops of potato (Solanum tuberosum L.), and three crops of soybean (Glycine max (L.) Merr.) grown in NASA's CELSS Biomass Production Chamber were analyzed for proximate composition. All plants were grown using recirculating nutrient (hydroponic) film culture with pH and electrical conductivity automatically controlled. Temperature and humidity were controlled to near optimal levels for each species and atmospheric carbon dioxide partial pressures were maintained near 100 Pa during the light cycles. Soybean seed contained the highest percentage of protein and fat, potato tubers and wheat seed contained the highest levels of carbohydrate, and lettuce leaves contained the highest level of ash. Analyses showed values close to data published for field-grown plants with several exceptions: In comparison with field-grown plants, wheat seed had higher protein levels; soybean seed had higher ash and crude fiber levels; and potato tubers and lettuce leaves had higher protein and ash levels. The higher ash and protein levels may have been a result of the continuous supply of nutrients (e.g., potassium and nitrogen) to the plants by the recirculating hydroponic culture.
Ming, Yang; Purewal, Justin; Yang, Jun; Xu, Chunchuan; Soltis, Rick; Warner, James; Veenstra, Mike; Gaab, Manuela; Müller, Ulrich; Siegel, Donald J
2015-05-05
Metal-organic frameworks (MOFs) are an emerging class of microporous, crystalline materials with potential applications in the capture, storage, and separation of gases. Of the many known MOFs, MOF-5 has attracted considerable attention because of its ability to store gaseous fuels at low pressure with high densities. Nevertheless, MOF-5 and several other MOFs exhibit limited stability upon exposure to reactive species such as water. The present study quantifies the impact of humid air exposure on the properties of MOF-5 as a function of exposure time, humidity level, and morphology (i.e., powders vs pellets). Properties examined include hydrogen storage capacity, surface area, and crystallinity. Water adsorption/desorption isotherms are measured using a gravimetric technique; the first uptake exhibits a type V isotherm with a sudden increase in uptake at ∼50% relative humidity. For humidity levels below this threshold only minor degradation is observed for exposure times up to several hours, suggesting that MOF-5 is more stable than generally assumed under moderately humid conditions. In contrast, irreversible degradation occurs in a matter of minutes for exposures above the 50% threshold. Fourier transform infrared spectroscopy indicates that molecular and/or dissociated water is inserted into the skeletal framework after long exposure times. Densification into pellets can slow the degradation of MOF-5 significantly, and may present a pathway to enhance the stability of some MOFs.
NASA Astrophysics Data System (ADS)
Gasiorowski, M.; Hercman, H.
2012-04-01
The Niedźwiedzia Cave is located in Śnieżnik Massif (the Easter Sudetes, SW Poland) at 800 m a.s.l. The length of known passages is ~3000 m and denivelation is 69 m. The system is composed of 3 levels of passages and chambers. It is a show cave with ~80,000 visitors every year. In 2010 we started monitoring program of cave air temperature and humidity, drip rate, stable isotopes and Uranium and Polonium content in water in selected sites inside the cave and in its vicinity. Changes in dropping rate in upper level are well correlated with precipitation. However, a response of dripping to rainfall depends on former precipitation frequency and intensity - during the humid period the dripping reacts immediately and after long dry period dripping responses with two-weeks delay. There is not so direct correlation between precipitation and dripping in lower level of the system. Air temperature inside the cave is almost stable in lower level (mean annual ~5.3 °C, and annual variation up to 0.7 °C) and more dynamic in the middle level (mean annual ~6.4 °C, and mean annual amplitude up to 4 °C). Daily and weekly measured changes of cave air temperature demonstrate extremely well correlation with number of visitors. In show cave passages (the middle level of the system) temperature increase 0.1-0.2 °C during every day when the cave is open for tourists and such changes is not observed during days without visitors and in lower level of the system closed for tourists. But even short visits of 3-4 cavers are recorded by temperature sensors exposed in the lower level (~0.02 °C increase). It proves very high sensitivity of cave environment to human activity. This study is funded by the National Science Centre and Higher Education grant no. N N306 131038.
Suma, A; Sreenivasan, Kalyani; Singh, A K; Radhamani, J
2013-01-01
The role of relative humidity (RH) while processing and storing seeds of Brassica spp. and Eruca sativa was investigated by creating different levels of relative humidity, namely, 75%, 50%, 32%, and 11% using different saturated salt solutions and 1% RH using concentrated sulphuric acid. The variability in seed storage behaviour of different species of Brassica was also evaluated. The samples were stored at 40 ± 2°C in sealed containers and various physiological parameters were assessed at different intervals up to three months. The seed viability and seedling vigour parameters were considerably reduced in all accessions at high relative humidity irrespective of the species. Storage at intermediate relative humidities caused minimal decline in viability. All the accessions performed better at relative humidity level of 32% maintaining seed moisture content of 3%. On analyzing the variability in storage behaviour, B. rapa and B. juncea were better performers than B. napus and Eruca sativa.
Absolute Humidity and the Seasonality of Influenza (Invited)
NASA Astrophysics Data System (ADS)
Shaman, J. L.; Pitzer, V.; Viboud, C.; Grenfell, B.; Goldstein, E.; Lipsitch, M.
2010-12-01
Much of the observed wintertime increase of mortality in temperate regions is attributed to seasonal influenza. A recent re-analysis of laboratory experiments indicates that absolute humidity strongly modulates the airborne survival and transmission of the influenza virus. Here we show that the onset of increased wintertime influenza-related mortality in the United States is associated with anomalously low absolute humidity levels during the prior weeks. We then use an epidemiological model, in which observed absolute humidity conditions temper influenza transmission rates, to successfully simulate the seasonal cycle of observed influenza-related mortality. The model results indicate that direct modulation of influenza transmissibility by absolute humidity alone is sufficient to produce this observed seasonality. These findings provide epidemiological support for the hypothesis that absolute humidity drives seasonal variations of influenza transmission in temperate regions. In addition, we show that variations of the basic and effective reproductive numbers for influenza, caused by seasonal changes in absolute humidity, are consistent with the general timing of pandemic influenza outbreaks observed for 2009 A/H1N1 in temperate regions. Indeed, absolute humidity conditions correctly identify the region of the United States vulnerable to a third, wintertime wave of pandemic influenza. These findings suggest that the timing of pandemic influenza outbreaks is controlled by a combination of absolute humidity conditions, levels of susceptibility and changes in population mixing and contact rates.
Formaldehyde levels in traditional and portable classrooms: A pilot investigation
2015-01-01
This pilot study assessed formaldehyde levels in portable classrooms (PCs) and traditional classrooms (TCs) and explored factors influencing indoor air quality (e.g., carbon dioxide (CO2), temperature, and relative humidity). In a cross-sectional design, we evaluated formaldehyde levels in day and overnight indoor air samples from nine PCs renovated within three years previously and three TCs in a school district in metropolitan Atlanta, Georgia. Formaldehyde levels ranged from 0.0068 to 0.038 ppm. In both type of classrooms, overnight formaldehyde median levels (PCs = 0.018 ppm; TCs = 0.019 ppm) were higher than day formaldehyde median levels (PCs = 0.011 ppm; TCs = 0.016 ppm). CO2 levels measured 470–790 parts per million (ppm) at 7AM and 470–1800 ppm at 4PM. Afternoon medians were higher in TCs (1,400 ppm ) than in PCs (780 ppm). Consistent with previous studies, formaldehyde levels were similar among PCs and TCs. Reducing CO2 levels by improving ventilation is recommended for classrooms. PMID:27197349
2014-01-01
Background Effects of water deficit on plant water status, gas exchange and hydraulic conductance were investigated in Betula pendula under artificially manipulated air humidity in Eastern Estonia. The study was aimed to broaden an understanding of the ability of trees to acclimate with the increasing atmospheric humidity predicted for northern Europe. Rapidly-induced water deficit was imposed by dehydrating cut branches in open-air conditions; long-term water deficit was generated by seasonal drought. Results The rapid water deficit quantified by leaf (ΨL) and branch water potentials (ΨB) had a significant (P < 0.001) effect on gas exchange parameters, while inclusion of ΨB in models resulted in a considerably better fit than those including ΨL, which supports the idea that stomatal openness is regulated to prevent stem rather than leaf xylem dysfunction. Under moderate water deficit (ΨL≥-1.55 MPa), leaf conductance to water vapour (gL), transpiration rate and leaf hydraulic conductance (KL) were higher (P < 0.05) and leaf temperature lower in trees grown in elevated air humidity (H treatment) than in control trees (C treatment). Under severe water deficit (ΨL<-1.55 MPa), the treatments showed no difference. The humidification manipulation influenced most of the studied characteristics, while the effect was to a great extent realized through changes in soil water availability, i.e. due to higher soil water potential in H treatment. Two functional characteristics (gL, KL) exhibited higher (P < 0.05) sensitivity to water deficit in trees grown under increased air humidity. Conclusions The experiment supported the hypothesis that physiological traits in trees acclimated to higher air humidity exhibit higher sensitivity to rapid water deficit with respect to two characteristics - leaf conductance to water vapour and leaf hydraulic conductance. Disproportionate changes in sensitivity of stomatal versus leaf hydraulic conductance to water deficit will impose greater risk of desiccation-induced hydraulic dysfunction on the plants, grown under high atmospheric humidity, in case of sudden weather fluctuations, and might represent a potential threat in hemiboreal forest ecosystems. There is no trade-off between plant hydraulic capacity and photosynthetic water-use efficiency on short time scale. PMID:24655599
Humidity effects on surface dielectric barrier discharge for gaseous naphthalene decomposition
NASA Astrophysics Data System (ADS)
Abdelaziz, Ayman A.; Ishijima, Tatsuo; Seto, Takafumi
2018-04-01
Experiments are performed using dry and humid air to clarify the effects of water vapour on the characteristics of surface dielectric barrier discharge (SDBD) and investigate its impact on the performance of the SDBD for decomposition of gaseous naphthalene in air stream. The current characteristics, including the discharge and the capacitive currents, are deeply analyzed and the discharge mechanism is explored. The results confirmed that the humidity affected the microdischarge distribution without affecting the discharge mode. Interestingly, it is found that the water vapour had a significant influence on the capacitance of the reactor due to its deposition on the discharge electrode and the dielectric, which, in turn, affects the power loss in the dielectric and the total power consumed in the reactor. Thus, the factor of the humidity effect on the power loss in the dielectric should be considered in addition to its effect on the attachment coefficient. Additionally, there was an optimum level of the humidity for the decomposition of naphthalene in the SDBD, and its value depended on the gas composition, where the maximum naphthalene decomposition efficiency in O2/H2O is achieved at the humidity level ˜10%, which was lower than that obtained in air/H2O (˜28%). The results also revealed that the role of the humidity in the decomposition efficiency was not significant in the humidified O2 at high power level. This was attributed to the significant increase in oxygen-derived species (such as O atoms and O3) at high power, which was enough to overcome the negative effects of the humidity.
Barros, Daniel Vale; Silva, Lilian Kátia Ximenes; de Brito Lourenço, José; da Silva, Aluizio Otávio Almeida; E Silva, André Guimarães Maciel; Franco, Irving Montanar; Oliveira, Carlos Magno Chaves; Tholon, Patrícia; Martorano, Lucieta Guerreiro; Garcia, Alexandre Rossetto
2015-06-01
This study aimed to assess the variation over time in thermal comfort indices and the behavior of physiological parameters related to thermolysis, blood parameters, and semen in natura of buffalo bulls reared in tropical climate. The study was carried out in an artificial insemination station under a humid tropical climate (Afi according to Köppen). Ten water buffalo bulls (Bubalus bubalis) were used during the 5 months (April to August) of study. The environmental Temperature Humidity Index (THId) and the pen microclimate Temperature Humidity Index (THIp) were calculated. Every 25 days, respiratory rate (RR), heart rate (HR), rectal temperature (RT), and Benezra's thermal comfort index (BTCI) were assessed in the morning and in the afternoon. A blood assay was performed every month, while semen was collected weekly. THIp did not vary over the months (P > 0.05) and was higher in the afternoon than in the morning (77.7 ± 2.6 versus 81.8 ± 2.1, P < 0.05). RR, HR, and BTCI significantly increased over the months and were different between the periods of the day (P > 0.05) but within the physiological limits. RT varied between the periods of the day and decreased over the months, being the lowest in August (37.8 ± 0.7 °C), time-impacted hematocrit, mean corpuscular volume, hemoglobin levels, and spermatic gross motility and vigor (P < 0.05). Thus, buffalo bulls reared under a humid tropical climate may have variations in thermal comfort during the hotter periods but are able to efficiently activate thermoregulatory mechanisms and maintain homeothermy, hence preserving their physiological and seminal parameters at normal levels.
Lihavainen, Jenna; Keinänen, Markku; Keski-Saari, Sarita; Kontunen-Soppela, Sari; Sõber, Anu; Oksanen, Elina
2016-01-01
Relative air humidity (RH) is expected to increase in northern Europe due to climate change. Increasing RH reduces the difference of water vapour pressure deficit (VPD) between the leaf and the atmosphere, and affects the gas exchange of plants. Little is known about the effects of decreased VPD on plant metabolism, especially under field conditions. This study was conducted to determine the effects of artificially decreased VPD on silver birch (Betula pendula Roth.) and hybrid aspen (Populus tremula L.×P. tremuloides Michx.) foliar metabolite and nutrient profiles in a unique free air humidity manipulation (FAHM) field experiment during the fourth season of humidity manipulation, in 2011. Long-term exposure to decreased VPD modified nutrient homeostasis in tree leaves, as demonstrated by a lower N concentration and N:P ratio in aspen leaves, and higher Na concentration and lower K:Na ratio in the leaves of both species in decreased VPD than in ambient VPD. Decreased VPD caused a shift in foliar metabolite profiles of both species, affecting primary and secondary metabolites. Metabolic adjustment to decreased VPD included elevated levels of starch and heptulose sugars, sorbitol, hemiterpenoid and phenolic glycosides, and α-tocopherol. High levels of carbon reserves, phenolic compounds, and antioxidants under decreased VPD may modify plant resistance to environmental stresses emerging under changing climate. PMID:27255929
Xi, Jinxiang; Kim, Jongwon; Si, Xiuhua A; Zhou, Yue
2013-01-01
The deposition of hygroscopic aerosols is highly complex in nature, which results from a cumulative effect of dynamic particle growth and the real-time size-specific deposition mechanisms. The objective of this study is to evaluate hygroscopic effects on the particle growth, transport, and deposition of nasally inhaled aerosols across a range of 0.2-2.5 μm in an adult image-based nose-throat model. Temperature and relative humidity fields were simulated using the LRN k-ω turbulence model and species transport model under a spectrum of thermo-humidity conditions. Particle growth and transport were simulated using a well validated Lagrangian tracking model coupled with a user-defined hygroscopic growth module. Results of this study indicate that the saturation level and initial particle size are the two major factors that determine the particle growth rate (d/d0), while the effect of inhalation flow rate is found to be not significant. An empirical correlation of condensation growth of nasally inhaled hygroscopic aerosols in adults has been developed based on a variety of thermo-humidity inhalation conditions. Significant elevated nasal depositions of hygroscopic aerosols could be induced by condensation growth for both sub-micrometer and small micrometer particulates. In particular, the deposition of initially 2.5 μm hygroscopic aerosols was observed to be 5-8 times that of inert particles under warm to hot saturated conditions. Results of this study have important implications in exposure assessment in hot humid environments, where much higher risks may be expected compared to normal conditions.
Air quality and ocular discomfort aboard commercial aircraft.
Backman, H; Haghighat, F
2000-10-01
Aircraft cabin air quality has been a subject of recent public health interest. Aircraft environments are designed according to standards to ensure the comfort and well-being of the occupants. The upper and lower limits of humidity set by ASHRAE standards are based on the maintenance of acceptable thermal conditions established solely on comfort considerations, including thermal sensation, skin wetness, skin dryness, dry eyes and ocular discomfort. The purpose of this study is to investigate the influence of air (carbon dioxide level, relative humidity, and temperature) aboard commercial aircraft on ocular discomfort and dry eye of aircraft personnel and passengers. Measurements of indoor air quality were performed in 15 different aircraft at different times and altitudes. Forty-two measurements of carbon dioxide, temperature, and humidity were performed with portable air samplers every 5 minutes. Passenger loads did not exceed 137 passengers. Thermal comfort rarely met ASHRAE standards. Low humidity levels and high carbon dioxide levels were found on the Airbus 320. The DC-9 had the highest humidity level and the Boeing-767 had the lowest carbon dioxide level. Air quality was poorest on the Airbus 320 aircraft. This poor level of air quality may cause intolerance to contact lenses, dry eyes, and may be a health hazard to both passengers and crew members. Improved ventilation and aircraft cabin micro-environments need to be made for the health and comfort of the occupants.
Braz, José R C; Braz, Mariana G; Hayashi, Yoko; Martins, Regina H G; Betini, Marluci; Braz, Leandro G; El Dib, Regina
2017-08-01
The minimum inhaled gas absolute humidity level is 20 mgH2O l for short-duration use in general anaesthesia and 30 mgH2O l for long-duration use in intensive care to avoid respiratory tract dehydration. The aim is to compare the effects of different fresh gas flows (FGFs) through a circle rebreathing system with or without a heat and moisture exchanger (HME) on inhaled gas absolute humidity in adults undergoing general anaesthesia. Systematic review and meta-analyses of randomised controlled trials. We defined FGF (l min) as minimal (0.25 to 0.5), low (0.6 to 1.0) or high (≥2). We extracted the inhaled gas absolute humidity data at 60 and 120 min after connection of the patient to the breathing circuit. The effect size is expressed as the mean differences and corresponding 95% confidence intervals (CI). PubMed, EMBASE, SciELO, LILACS and CENTRAL until January 2017. We included 10 studies. The inhaled gas absolute humidity was higher with minimal flow compared with low flow at 120 min [mean differences 2.51 (95%CI: 0.32 to 4.70); P = 0.02] but not at 60 min [mean differences 2.95 (95%CI: -0.95 to 6.84); P = 0.14], and higher with low flow compared with high flow at 120 min [mean differences 7.19 (95%CI: 4.53 to 9.86); P < 0.001]. An inhaled gas absolute humidity minimum of 20 mgH2O l was attained with minimal flow at all times but not with low or high flows. An HME increased the inhaled gas absolute humidity: with minimal flow at 120 min [mean differences 8.49 (95%CI: 1.15 to 15.84); P = 0.02]; with low flow at 60 min [mean differences 9.87 (95%CI: 3.18 to 16.57); P = 0.04] and 120 min [mean differences 7.19 (95%CI: 3.29 to 11.10); P = 0.003]; and with high flow of 2 l min at 60 min [mean differences 6.46 (95%CI: 4.05 to 8.86); P < 0.001] and of 3 l min at 120 min [mean differences 12.18 (95%CI: 6.89 to 17.47); P < 0.001]. The inhaled gas absolute humidity data attained or were near 30 mgH2O l when an HME was used at all FGFs and times. All intubated patients should receive a HME with low or high flows. With minimal flow, a HME adds cost and is not needed to achieve an appropriate inhaled gas absolute humidity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osborne, T.S.; Lunden, A.O.; Constantin, M.J.
1963-01-01
Seeds of Brassica napus L. (Cruciferae), Festuca elatior L. (Gramineae), Lactuca sativa L. (Compositae), Lycopersicon escuientum Mill. (Solanaceae), and Trifolium incarnatum L. var. elatius Gibelli & Belli (Leguminosae) were equilibrated at relative humidities of 10, 35, 60, and 85 per cent then exposed to gamma-ray doses of 0, 10, 20, for 14 to 16 days in a controlled environment and assayed for dry weight. Data were analyzed by a full-quadratic regression model. Except for Festuca, growth from irradiated and control seeds was drastically affected by preirradiation humidity, with higher humidities generally more damaging than iower but with growth decreasing bothmore » above and below an optimum humidity. Optimum humidity varied with species, ranging from 9 to 38 per cent R. H. in the controls, and with radiation treatment, ranging from 42 to 53 per cent R. H. at the highest doses tolerated. The hypothesis of persisting radiation-induced radicals at lower humidities does not explain the similar increase in radiosensitivity at humidities above the optimum. (auth)« less
Jiang, Huawei; Sahu, Binod Bihari; Kambakam, Sekhar; Singh, Prashant; Wang, Xinran; Wang, Qiugu; Bhattacharyya, Madan K.; Dong, Liang
2016-01-01
This paper reports a highly economical and accessible approach to generate different discrete relative humidity conditions in spatially separated wells of a modified multi-well plate for humidity assay of plant-pathogen interactions with good throughput. We demonstrated that a discrete humidity gradient could be formed within a few minutes and maintained over a period of a few days inside the device. The device consisted of a freeway channel in the top layer, multiple compartmented wells in the bottom layer, a water source, and a drying agent source. The combinational effects of evaporation, diffusion, and convection were synergized to establish the stable discrete humidity gradient. The device was employed to study visible and molecular disease phenotypes of soybean in responses to infection by Phytophthora sojae, an oomycete pathogen, under a set of humidity conditions, with two near-isogenic soybean lines, Williams and Williams 82, that differ for a Phytophthora resistance gene (Rps1-k). Our result showed that at 63% relative humidity, the transcript level of the defense gene GmPR1 was at minimum in the susceptible soybean line Williams and at maximal level in the resistant line Williams 82 following P. sojae CC5C infection. In addition, we investigated the effects of environmental temperature, dimensional and geometrical parameters, and other configurational factors on the ability of the device to generate miniature humidity environments. This work represents an exploratory effort to economically and efficiently manipulate humidity environments in a space-limited device and shows a great potential to facilitate humidity assay of plant seed germination and development, pathogen growth, and plant-pathogen interactions. Since the proposed device can be easily made, modified, and operated, it is believed that this present humidity manipulation technology will benefit many laboratories in the area of seed science, plant pathology, and plant-microbe biology, where humidity is an important factor that influences plant disease infection, establishment, and development. PMID:27279932
Humidity does not appear to trigger leaf out in woody plants
NASA Astrophysics Data System (ADS)
Zipf, Lucy; Primack, Richard B.
2017-12-01
In order to anticipate the ecological impacts of climate change and model changes to forests, it is important to understand the factors controlling spring leaf out. Leaf out phenology in woody trees and shrubs is generally considered to be strongly controlled by a combination of spring warming, winter chilling requirement, and photoperiod. However, researchers have recently suggested that temperature-related air humidity, rather than temperature itself, might be the main trigger of the spring leaf-out of woody plants. Here, we sought to examine the relationship between air humidity and leaf-out across a range of humidities and plant functional groups. We did not find any consistent, measurable effect of high humidity advancing leaf-out in the 15 woody shrubs and trees examined in this study, and we did not see progressive patterns of earlier leaf-out in successively higher humidities. Our results indicate that more work must be done on this topic before researchers can properly determine the effect of humidity on the leafing out process for woody species.
Noncontact Measurement of Humidity and Temperature Using Airborne Ultrasound
NASA Astrophysics Data System (ADS)
Kon, Akihiko; Mizutani, Koichi; Wakatsuki, Naoto
2010-04-01
We describe a noncontact method for measuring humidity and dry-bulb temperature. Conventional humidity sensors are single-point measurement devices, so that a noncontact method for measuring the relative humidity is required. Ultrasonic temperature sensors are noncontact measurement sensors. Because water vapor in the air increases sound velocity, conventional ultrasonic temperature sensors measure virtual temperature, which is higher than dry-bulb temperature. We performed experiments using an ultrasonic delay line, an atmospheric pressure sensor, and either a thermometer or a relative humidity sensor to confirm the validity of our measurement method at relative humidities of 30, 50, 75, and 100% and at temperatures of 283.15, 293.15, 308.15, and 323.15 K. The results show that the proposed method measures relative humidity with an error rate of less than 16.4% and dry-bulb temperature with an error of less than 0.7 K. Adaptations of the measurement method for use in air-conditioning control systems are discussed.
Moustafa, Islam O F; Ali, Mohammed R A-A; Al Hallag, Moataz; Rabea, Hoda; Fink, James B; Dailey, Patricia; Abdelrahim, Mohamed E A
During mechanical ventilation medical aerosol delivery has been reported to be upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5 h post dose (URSAL0.5%) has been confirmed as an index of lung deposition and 24 h (URSAL24%) as index of systemic absorption. Our aim was to determine the effect of humidification and aerosol device type on drug delivery to ventilated patients using urine levels. In a randomized crossover design, 36 (18female) mechanically ventilated patients were assigned to one of three groups. Groups 1 and 2 received 5000 μg salbutamol using vibrating mesh (VM) and jet nebulizers (JN), respectively, while group 3 received 1600 μg (16 puffs) of salbutamol via metered dose inhaler with AeroChamber Vent (MDI-AV). All devices were placed in the inspiratory limb of ventilator downstream from the humidifier. Each subject received aerosol with and without humidity at >24 h intervals with >12 h washout periods between salbutamol doses. Patients voided urine 15 min before each study dose and urine samples were collected at 0.5 h post dosing and pooled for the next 24 h. The MDI-AV and VM resulted in a higher percentage of urinary salbutamol levels compared to the JN (p < 0.05). Urine levels were similar between humidity and dry conditions. Our findings suggest that in-vitro reports overestimate the impact of dry vs. heated humidified conditions on the delivery of aerosol during invasive mechanical ventilation. Copyright © 2017 Elsevier Inc. All rights reserved.
High-resolution humidity profiles retrieved from wind profiler radar measurements
NASA Astrophysics Data System (ADS)
Saïd, Frédérique; Campistron, Bernard; Di Girolamo, Paolo
2018-03-01
The retrieval of humidity profiles from wind profiler radars has already been documented in the past 30 years and is known to be neither as straightforward and nor as robust as the retrieval of the wind velocity. The main constraint to retrieve the humidity profile is the necessity to combine measurements from the wind profiler and additional measurements (such as observations from radiosoundings at a coarser time resolution). Furthermore, the method relies on some assumptions and simplifications that restrict the scope of its application. The first objective of this paper is to identify the obstacles and limitations and solve them, or at least define the field of applicability. To improve the method, we propose using the radar capacity to detect transition levels, such as the top level of the boundary layer, marked by a maximum in the radar reflectivity. This forces the humidity profile from the free troposphere and from the boundary layer to coincide at this level, after an optimization of the calibration coefficients, and reduces the error. The resulting mean bias affecting the specific humidity profile never exceeds 0.25 g kg-1. The second objective is to explore the capability of the algorithm to retrieve the humidity vertical profiles for an operational purpose by comparing the results with observations from a Raman lidar.
Tamerius, JD; Perzanowski, MS; Acosta, LM; Jacobson, JS; Goldstein, IF; Quinn, JW; Rundle, AG; Shaman, J
2013-01-01
Background Numerous mechanisms link outdoor weather and climate conditions to human health. It is likely that many health conditions are more directly affected by indoor rather than outdoor conditions. Yet, the relationship between indoor temperature and humidity conditions to outdoor variability, and the heterogeneity of the relationship among different indoor environments are largely unknown. Methods We use 5–14 day measures of indoor temperature and relative humidity from 327 dwellings in New York City for the years 2008–2011 to investigate the relationship between indoor climate, outdoor meteorological conditions, socioeconomic conditions, and building descriptors. Study households were primarily middle-income and located across the boroughs of Brooklyn, Queens, Bronx, and Manhattan. Results Indoor temperatures are positively associated with outdoor temperature during the warm season and study dwellings in higher socioeconomic status neighborhoods are significantly cooler. During the cool season, outdoor temperatures have little effect on indoor temperatures; however, indoor temperatures can range more than 10 °C between dwellings despite similar outdoor temperatures. Apartment buildings tend to be significantly warmer than houses and dwellings on higher floors are also significantly warmer than dwellings on lower floors. Outdoor specific humidity is positively associated with indoor specific and relative humidity, but there is no consistent relationship between outdoor and indoor relative humidity. Conclusions In New York City, the relationship between indoor and outdoor temperature and humidity conditions vary significantly between dwellings. These results can be used to inform studies of health outcomes for which temperature or humidity is an established factor affecting human health and highlights the need for more research on the determinants of indoor climate. PMID:24077420
Humidification during high-frequency oscillatory ventilation for adults: a bench study.
Chikata, Yusuke; Imanaka, Hideaki; Ueta, Masahiko; Nishimura, Masaji
2010-12-01
High-frequency oscillatory ventilation (HFOV) has recently been applied to acute respiratory distress syndrome patients. However, the issue of humidification during HFOV has not been investigated. In a bench study, we evaluated humidification during HFOV for adults to test if adequate humidification was achieved in 2 different HFOV systems. We tested 2 brands of adult HFOV ventilators, the R100 (Metran, Japan) and the 3100B (SensorMedics, CA), under identical bias flow. A heated humidifier consisting of porous hollow fiber (Hummax II, Metran) was set for the R100, and a passover-type heated humidifier (MR850, Fisher & Paykel) was set for the 3100B, while inspiratory heating wire was applied to both systems. Each ventilator was connected to a lung model in an incubator. Absolute humidity, relative humidity and temperature at the airway opening were measured using a hygrometer under a variety of ventilatory settings: 3 stroke volumes/amplitudes, 3 frequencies, and 2 mean airway pressures. The R100 ventilator showed higher absolute humidity, higher relative humidity, and lower temperature than the 3100B. In the R100, as stroke volume and frequency increased, absolute humidity and temperature increased. In the 3100B, amplitude, frequency, and mean airway pressure minimally affected absolute humidity and temperature. Relative humidity was almost 100% in the R100, while it was 80.5±2.3% in the 3100B. Humidification during HFOV for adults was affected by stroke volume and frequency in the R100, but was not in the 3100B. Absolute humidity was above 33 mgH_2 O/L in these 2 systems under a range of settings.
Zhang, Pan-pan; Zhou, Yu; Song, Hui; Qiao, Zhi-jun; Wang, Hai-gang; Zheng, Dian-feng; Feng, Bai-li
2015-02-01
A field experiment with two broomcorn millet varieties Longmi 8 (strong drought-resistant variety) and Jinmi 4 (drought-sensitive variety) was conducted to compare their differences in growth, field microclimate and photosynthetic capacity from anthesis to maturity under different fertility conditions. The results showed that, fertilization decreased canopy temperature, air temperature, soil temperature, illumination, but improved the relative humidity among broomcorn millet plants compared with the non-fertilization treatment. With an increase of the fertilizer level, the plant height, SPAD, LAI, net photosynthetic rate, transpiration rate, stomatal conductance, intercellular CO2 concentration in broomcorn millet showed an increasing trend, which of the high fertilization treatment were 9.2%, 15.1%, 56.6%, 17.8%, 24.6%, 14.2%, 29.7% higher than those of non-fertilization treatment, respectively. Compared with Jinmi 4, Longmi 8 showed a cold wet characteristic, with lower canopy temperature, air temperature, soil temperature; illumination, and higher plant height, LAI, SPAD and relative humidity during grain filling. Moreover, each photosynthetic index of Longmi 8 slowly decreased and extended the period of leaf photosynthetic function so as to accumulate more photosynthetic products.
An investigation of thermal comfort at high humidities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fountain, M.E.; Arens, E. Xu, T.; Bauman, F.S.
1999-07-01
Climate chamber experiments were performed to investigate thermal comfort at high humidities. Subjective reports were recorded for a total of 411 subjects at frequent intervals during the three-hour experiments with 65 selected subjects equipped with instrumentation to record skin wettedness and skin temperature. The exposures ranged from 20 C/60% RH to 26 C/90% RH with two clothing levels, 0.5 and 0.9 clo, and three levels of metabolic activity, 1.2, 1.6, and 4 met. Clear differences in humidity response were not found for sedentary subjects; however, non-sedentary activities produced differences on several subjective scales. These differences, though, are dictated via heatmore » balance and thermoregulation and cannot be separated from humidity-related effects. For metabolic rates 1.6 met and above, these data suggest that no practical limit on humidity will lower the percent dissatisfied below 25%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, R.; Hendron, R.; Eastment, M.
2006-12-01
This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.
Niven, R; Fletcher, A M; Pickering, A C; Custovic, A; Sivour, J B; Preece, A R; Oldham, L A; Francis, H C
1999-05-01
Allergen avoidance is of considerable interest in the treatment and even prevention of asthma. Attempts to control house dust mites have included environmental manipulation in homes in an attempt to reduce humidity below a level that favors mite survival. This appears to have some benefit in Scandinavia, but a previous attempt with mechanical ventilation heat pump recovery (MVHR) units in the UK failed to achieve the desired results. We report a study using an additional central dehumidification modification of the MVHR (MVHRcd) in an attempt to reduce allergen levels in houses of asthmatic subjects. Ten houses of asthmatic patients allergic to dust mites and 10 architectural control houses were studied. The active houses were fitted with an MVHRcd unit in November/December 1994 and activated in January 1995. The active and control houses were monitored continuously for internal temperature and humidity by using digital sensors in the asthmatic and control bedrooms. Dust samples were collected to determine allergen levels at baseline (January 1994) and 3, 6, 9, and 15 months after switching on the units. The winter seasonal average humidity fell from 50% relative humidity (RH) in control bedrooms to 37% RH in asthmatic bedrooms compared with 72% RH in the ambient air as measured on the intake of the MVHRcd systems. There was no corresponding change in seasonal mean temperature within the houses. Although the temperature and humidity weekly and seasonal means remained below the study target of 45% RH or 7 g/kg absolute humidity at 21 degrees C, there were transient rises in humidity detected by the sensors in the houses with MVHRcd systems. Allergen levels fell both in active and control houses during the study period, but there was no significant advantage gained from the installation of MVHRcd systems. The MVHRcd system failed to confer a benefit in terms of mite allergen reduction despite apparently adequate control of temperature and humidity.
NASA Technical Reports Server (NTRS)
Hooker, M. W.; Wise, S. A.; Carlberg, I. A.; Stephens, R. M.; Simchick, R. T.; Farjami, A.
1993-01-01
An aging study was performed to determine the stability of YBa2Cu3O(7-x) ceramics in humid environments at 20 C. In this study, fired ceramic specimens were exposed to humidity levels ranging from 30.5 to 100 percent for 2-, 4-, and 6-week time intervals. After storage under these conditions, the specimens were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and electrical resistance measurements. At every storage condition evaluated, the fired ceramics were found to interact with H2O present in the surrounding environment, resulting in the decomposition of the YBa2Cu3O(7-x) phase. XRD data showed that BaCO3, CuO, and Y2BaCuO5 were present after aging and that the peak intensities of these impurity phases increased both with increasing humidity level and with increasing time of exposure. Additionally, SEM analyses of the ceramic microstructures after aging revealed the development of needle-like crystallites along the surface of the test specimens after aging. Furthermore, the superconducting transition temperature T(sub c) was found to decrease both with increasing humidity level and with increasing time of exposure. All the specimens aged at 30.5, 66, and 81 percent relative humidity exhibited superconducting transitions above 80 K, although these values were reduced by the exposure to the test conditions. Conversely, the specimens stored in direct contact with water (100 percent relative humidity) exhibited no superconducting transitions.
Rahmathulla, V. K.; Suresh, H. M.
2012-01-01
Food consumption and utilization is influenced by various biotic and abiotic factors. Under different environmental, feeding, and nutritional conditions, and with ingestion of the same amount of mulberry leaves, the silkworm shows significant difference in its ability to digest, absorb, and convert food to body matter. Here, influences of season, temperature, and humidity on food intake, assimilation, and conversion efficiency of the Indian bivoltine hybrid (CSR2 × CSR4) Bombyx mori L. (Lepidoptera: Bombycidae) were studied. The results indicated that food ingestion and assimilation were significantly higher among silkworm batches where optimum temperature and humidity were maintained compared with silkworm batches exposed to natural climatic conditions of the respective season. However, during summer the nutritional efficiency parameters were significantly higher among silkworms reared under natural temperature and humidity conditions when compared with the control. During the winter and rainy season, the nutritional efficiency parameters were significantly higher in control batches, where optimum temperature and humidity were maintained. Ingesta and digesta required to produce one gram of cocoon/shell were also lower in control batches for all seasons except summer. This may be due to the physiological adaptation of silkworms to overcome stress during the summer season. PMID:23414194
Beck, John J; Willett, Denis S; Gee, Wai S; Mahoney, Noreen E; Higbee, Bradley S
2016-12-14
Contamination by aflatoxin, a toxic metabolite produced by Aspergillus fungi ubiquitous in California almond and pistachio orchards, results in millions of dollars of lost product annually. Current detection of aflatoxin relies on destructive, expensive, and time-intensive laboratory-based methods. To explore an alternative method for the detection of general fungal growth, volatile emission profiles of almonds at varying humidities were sampled using both static SPME and dynamic needle-trap SPE followed by benchtop and portable GC-MS analysis. Despite the portable SPE/GC-MS system detecting fewer volatiles than the benchtop system, both systems resolved humidity treatments and identified potential fungal biomarkers at extremely low water activity levels. This ability to resolve humidity levels suggests that volatile profiles from germinating fungal spores could be used to create an early warning, nondestructive, portable detection system of fungal growth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The purpose of this project by Building Science Corporation was to evaluate the humidity control performance of new single family high performance homes, and compare the interior conditions and mechanical systems operation between two distinct groups of houses: homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012, and interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiersmore » are limiting elevated levels of humidity in the living space; however, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.« less
Humidity affects the performance of von Frey monofilaments.
Werner, M U; Rotbøll-Nielsen, P; Ellehuus-Hilmersson, C
2011-05-01
Assessment of tactile and nociceptive thresholds of the skin with calibrated polyamide monofilaments is an established testing method both in animal and in human research. It is known that changes in relative humidity may affect the physical properties of the monofilaments. As this effect has only been studied in very small diameter monofilaments, used in neonatal research, we therefore studied complete sets of polyamide monofilaments. The effects were studied in a controlled climate chamber during six incremental changes in relative humidity from 20% to 79% (22-24°C). Following 24 h of equilibration at each humidity level, calibration with a precision scale was performed. A highly significant linear correlation between the natural logarithm (In) of the bending force and the von Frey number was observed at all humidity levels (r(2)>0.99, P<0.0001). An inverse linear relationship between relative humidity and In of the bending force for each monofilament was found (r(2)=0.95, P<0.0001). One percent increase in relative humidity corresponded to a 1-4% relative decrease in numerical bending force, depending on the diameter of the monofilament. A significant linear relationship was observed between the coefficient of variation and the relative humidity (r(2)=0.87, P<0.001). The data indicate that the hygroscopic properties of polyamide monofilaments must be taken into account for their reliable use in quantitative sensory testing.
The effect of humidity on engine power at altitude
NASA Technical Reports Server (NTRS)
Brooks, D G; Garlock, E A
1933-01-01
From tests made in the altitude chamber of the Bureau of Standards, it was found that the effect of humidity on engine power is the same at altitudes up to 25,000 feet as at sea level. Earlier tests on automotive engines, made under sea-level conditions, showed that water vapor acts as an inert diluent, reducing engine power in proportion to the amount of vapor present. By combining the effects of atmospheric pressure, temperature, and humidity, it is shown that the indicated power obtainable from an engine is proportional to its mass rate of consumption of oxygen. This has led the National Advisory Committee for Aeronautics to adopt a standard basis for the correction of engine performance, in which the effect of humidity is included.
Semiparametric Modeling of Daily Ammonia Levels in Naturally Ventilated Caged-Egg Facilities
Gutiérrez-Zapata, Diana María; Galeano-Vasco, Luis Fernando; Cerón-Muñoz, Mario Fernando
2016-01-01
Ammonia concentration (AMC) in poultry facilities varies depending on different environmental conditions and management; however, this is a relatively unexplored subject in Colombia (South America). The objective of this study was to model daily AMC variations in a naturally ventilated caged-egg facility using generalized additive models. Four sensor nodes were used to record AMC, temperature, relative humidity and wind speed on a daily basis, with 10 minute intervals for 12 weeks. The following variables were included in the model: Heat index, Wind, Hour, Location, Height of the sensor to the ground level, and Period of manure accumulation. All effects included in the model were highly significant (p<0.001). The AMC was higher during the night and early morning when the wind was not blowing (0.0 m/s) and the heat index was extreme. The average and maximum AMC were 5.94±3.83 and 31.70 ppm, respectively. Temperatures above 25°C and humidity greater than 80% increased AMC levels. In naturally ventilated caged-egg facilities the daily variations observed in AMC primarily depend on cyclic variations of the environmental conditions and are also affected by litter handling (i.e., removal of the bedding material). PMID:26812150
NASA Astrophysics Data System (ADS)
Kaczmarek, Anna
2017-10-01
Contemporary single-family houses in Poland are often built during 3 quarters of a year (spring to autumn) are usually settled in a winter season. It is a special case when exploitation humidity coincides with technological one, causing unfavourable humidity conditions during the first years of exploitation. In consequence, thermal parameters of partitions differ from those assumed in the project. In construction stage the humidity state of a wall stabilizes as a result of water: associated with storage, entered technologically during wall construction and plastering, coming from rainfall. Thermo-insulation materials are built-in at dry state. During erection and exploitation of a building their thermal conductivity is changing depending on humidity conditions. According to building rules, construction humidity should be removed from a partition before the building transfer to usage, because it lowers the thermal partition insulation ability and increases air humidity of building interior. Walls are plastered and insulated in condition of simultaneous presence of atmospheric and technological humidity which cause special humidity condition during first years of exploitation. As a consequence, heating costs are substantially higher. In this article the results of simulation are shown performed with WUFI ®PRO 5 software, which was intended to define the time necessary for reaching the stabilised humidity in selected solutions of two-layer walls applied in a heated building. In the research performed, the partition orientation along geographic directions, short and long wave radiation, and environment humidity (air humidity, driving rain) coincidence with technological humidity in assumed wall solutions were taken into account.
Volatilization of pesticides from the bare soil surface: evaluation of the humidity effect.
Schneider, Martina; Endo, Satoshi; Goss, Kai-Uwe
2013-01-01
Volatilization of pesticides from soils under dry conditions (water content below the permanent wilting point) can be significantly influenced by sorption to hydrated mineral surfaces. This sorption process strongly depends on the water activity, expressed as equilibrium relative humidity in the pore space of the soil, and on the available surface area of the hydrated minerals. In this study, the influence of different humidity regimes on the volatilization of two pesticides (triallate and trifluralin) was demonstrated with a bench-scale wind tunnel system that allowed the establishment of well controlled humidity conditions within the soil. In the experiment starting with very dry conditions, increasing the relative humidity in the adjacent air from 60 to 85% resulted in an up to 8 times higher volatilization rate of the pesticides. An additional strong increase in volatilization (up to 3 times higher) was caused by a simulated rain event, which eliminates all sorption sites associated to mineral surfaces. In agreement with this interpretation, the comparison of two soils suggested that mineral surface area was the soil property that governs the volatilization under dry conditions, whereas soil organic matter was the controlling variable under wet conditions. In contrast to expectations, the use of a novel capsulated suspension for triallate showed the same humidity effects and no substantially lower volatilization rates in comparison to the regular formulation. This study demonstrated that humidity effects on pesticide volatilization can be interpreted via the mechanism of sorption to mineral surfaces under dry conditions. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Do honeybees, Apis mellifera scutellata, regulate humidity in their nest?
NASA Astrophysics Data System (ADS)
Human, Hannelie; Nicolson, Sue W.; Dietemann, Vincent
2006-08-01
Honeybees are highly efficient at regulating the biophysical parameters of their hive according to colony needs. Thermoregulation has been the most extensively studied aspect of nest homeostasis. In contrast, little is known about how humidity is regulated in beehives, if at all. Although high humidity is necessary for brood development, regulation of this parameter by honeybee workers has not yet been demonstrated. In the past, humidity was measured too crudely for a regulation mechanism to be identified. We reassess this issue, using miniaturised data loggers that allow humidity measurements in natural situations and at several places in the nest. We present evidence that workers influence humidity in the hive. However, there are constraints on potential regulation mechanisms because humidity optima may vary in different locations of the nest. Humidity could also depend on variable external factors, such as water availability, which further impair the regulation. Moreover, there are trade-offs with the regulation of temperature and respiratory gas exchanges that can disrupt the establishment of optimal humidity levels. As a result, we argue that workers can only adjust humidity within sub-optimal limits.
Mejia-Velasquez, Paula J; Dilcher, David L; Jaramillo, Carlos A; Fortini, Lucas B; Manchester, Steven R
2012-11-01
Reconstruction of floristic patterns during the early diversification of angiosperms is impeded by the scarce fossil record, especially in tropical latitudes. Here we collected quantitative palynological data from a stratigraphic sequence in tropical South America to provide floristic and climatic insights into such tropical environments during the Early Cretaceous. We reconstructed the floristic composition of an Aptian-Albian tropical sequence from central Colombia using quantitative palynology (rarefied species richness and abundance) and used it to infer its predominant climatic conditions. Additionally, we compared our results with available quantitative data from three other sequences encompassing 70 floristic assemblages to determine latitudinal diversity patterns. Abundance of humidity indicators was higher than that of aridity indicators (61% vs. 10%). Additionally, we found an angiosperm latitudinal diversity gradient (LDG) for the Aptian, but not for the Albian, and an inverted LDG of the overall diversity for the Albian. Angiosperm species turnover during the Albian, however, was higher in humid tropics. There were humid climates in northwestern South America during the Aptian-Albian interval contrary to the widespread aridity expected for the tropical belt. The Albian inverted overall LDG is produced by a faster increase in per-sample angiosperm and pteridophyte diversity in temperate latitudes. However, humid tropical sequences had higher rates of floristic turnover suggesting a higher degree of morphological variation than in temperate regions.
Mejia-Velasquez, Paula J.; Dilcher, David L.; Jaramillo, Carlos A.; Fortini, Lucas B.; Manchester, Steven R.
2012-01-01
Premise of the study: Reconstruction of floristic patterns during the early diversification of angiosperms is impeded by the scarce fossil record, especially in tropical latitudes. Here we collected quantitative palynological data from a stratigraphic sequence in tropical South America to provide floristic and climatic insights into such tropical environments during the Early Cretaceous. Methods: We reconstructed the floristic composition of an Aptian-Albian tropical sequence from central Colombia using quantitative palynology (rarefied species richness and abundance) and used it to infer its predominant climatic conditions. Additionally, we compared our results with available quantitative data from three other sequences encompassing 70 floristic assemblages to determine latitudinal diversity patterns. Key results: Abundance of humidity indicators was higher than that of aridity indicators (61% vs. 10%). Additionally, we found an angiosperm latitudinal diversity gradient (LDG) for the Aptian, but not for the Albian, and an inverted LDG of the overall diversity for the Albian. Angiosperm species turnover during the Albian, however, was higher in humid tropics. Conclusions: There were humid climates in northwestern South America during the Aptian-Albian interval contrary to the widespread aridity expected for the tropical belt. The Albian inverted overall LDG is produced by a faster increase in per-sample angiosperm and pteridophyte diversity in temperate latitudes. However, humid tropical sequences had higher rates of floristic turnover suggesting a higher degree of morphological variation than in temperate regions.
Significance of air humidity and air velocity for fungal spore release into the air
NASA Astrophysics Data System (ADS)
Pasanen, A.-L.; Pasanen, P.; Jantunen, M. J.; Kalliokoski, P.
Our previous field studies have shown that the presence of molds in buildings does not necessarily mean elevated airborne spore counts. Therefore, we investigated the release of fungal spores from cultures of Aspergillus fumigatus, Penicillium sp. and Cladosporium sp. at different air velocities and air humidities. Spores of A. fumigatus and Penicillium sp. were released from conidiophores already at air velocity of 0.5 ms -1, whereas Cladosporium spores required at least a velocity of 1.0 ms -1. Airborne spore counts of A. fumigatus and Penicillium sp. were usually higher in dry than moist air, being minimal at relative humidities (r.h.) above 70%, while the effect of r.h. on the release of Cladosporium sp. was ambivalent. The geometric mean diameter of released spores increased when the r.h. exceeded a certain level which depends on fungal genus. Thus, spores of all three fungi were hygroscopic but the hygroscopicity of various spores appeared at different r.h.-ranges. This study indicates that spore release is controlled by external factors and depends on fungal genus which can be one reason for considerable variation of airborne spore counts in buildings with mold problems.
A new method to obtain Fourier transform infrared spectra free from water vapor disturbance.
Chen, Yujing; Wang, Hai-Shui; Umemura, Junzo
2010-10-01
Infrared absorption bands due to water vapor in the mid-infrared regions often obscure important spectral features of the sample. Here, we provide a novel method to collect a qualified infrared spectrum without any water vapor interference. The scanning procedure for a single-beam spectrum of the sample is divided into two stages under an atmosphere with fluctuating humidity. In the first stage, the sample spectrum is measured with approximately the same number of scans as the background. If the absorbance of water vapor in the spectrum is positive (or negative) at the end of the first stage, then the relative humidity in the sample compartment of the spectrometer is changed by a dry (or wet) air blow at the start of the second stage while the measurement of the sample spectrum continues. After the relative humidity changes to a lower (or higher) level than that of the previously collected background spectrum, water vapor peaks will become smaller and smaller with the increase in scanning number during the second stage. When the interfering water lines disappear from the spectrum, the acquisition of a sample spectrum is terminated. In this way, water vapor interference can finally be removed completely.
Deng, Shawn; Hassan, Mohammad K.; Nalawade, Amol; ...
2015-09-16
Hot (at 120 °C) and dry (20% relative humidity) operating conditions benefit fuel cell designs based on proton exchange membranes (PEMs) and hydrogen due to simplified system design and increasing tolerance to fuel impurities. In this paper, presented are preparation, partial characterization, and multi-scale modeling of such PEMs based on cross-linked, sulfonated poly(1,3-cyclohexadiene) (xsPCHD) blends and block copolymers with poly(ethylene glycol) (PEG). These low cost materials have proton conductivities 18 times that of current industry standard Nafion at hot, dry operating conditions. Among the membranes studied, the blend xsPCHD-PEG PEM displayed the highest proton conductivity, which exhibits a morphology withmore » higher connectivity of the hydrophilic domain throughout the membrane. Simulation and modeling provide a molecular level understanding of distribution of PEG within this hydrophilic domain and its relation to proton conductivities. Finally, this study demonstrates enhancement of proton conductivity at high temperature and low relative humidity by incorporation of PEG and optimized sulfonation conditions.« less
Ramachandran, S; Srivastava, Rohit
2013-05-01
Aerosol optical properties of external and core-shell mixtures of aerosol species present in the atmosphere are calculated in this study for different relative humidities. Core-shell Mie calculations are performed using the values of radii, refractive indices and densities of aerosol species that act as core and shell, and the core-shell radius ratio. The single scattering albedo (SSA) is higher when the absorbing species (black carbon, BC) is the core, while for a sulfate core SSA does not vary significantly as the BC in the shell dominates the absorption. Absorption gets enhanced in core-shell mixing of absorbing and scattering aerosols when compared to their external mixture. Thus, SSA is significantly lower for a core-shell mixture than their external mixture. SSA is more sensitive to core-shell ratio than mode radius when BC is the core. The extinction coefficient, SSA and asymmetry parameter are higher for external mixing when compared to BC (core)-water soluble aerosol (shell), and water soluble aerosol (core)-BC (shell) mixtures in the relative humidity range of 0 to 90%. Spectral SSA exhibits the behaviour of the species which acts as a shell in core-shell mixing. The asymmetry parameter for an external mixture of water soluble aerosol and BC is higher than BC (core)-water soluble aerosol (shell) mixing and increases as function of relative humidity. The asymmetry parameter for the water soluble aerosol (core)-BC (shell) is independent of relative humidity as BC is hydrophobic. The asymmetry parameter of the core-shell mixture decreases when BC aerosols are involved in mixing, as the asymmetry parameter of BC is lower. Aerosol optical depth (AOD) of core-shell mixtures increases at a higher rate when the relative humidity exceeds 70% in continental clean and urban aerosol models, whereas AOD remains the same when the relative humidity exceeds 50% in maritime aerosol models. The SSA for continental aerosols varies for core-shell mixing of water soluble aerosol (core)-shell (BC) when compared to their external mixture, while the SSA for maritime aerosols does not vary significantly for different mixing scenarios because of the dominance of sea salt aerosols. Thus, these results confirm that aerosol mixing can modify the physical and optical characteristics of aerosols, which vary as a function of relative humidity. These calculations will be useful in parameterising the effect of core-shell vs. external mixing of aerosols in global climate models, and in the evaluation of aerosol radiative effects.
Anoxic conditions drive phosphorus limitation in humid tropical forest soil microorganisms
NASA Astrophysics Data System (ADS)
Gross, A.; Pett-Ridge, J.; Weber, P. K.; Blazewicz, S.; Silver, W. L.
2017-12-01
The elemental stoichiometry of carbon (C), nitrogen (N) and phosphorus (P) of soil microorganisms (C:N:P ratios) regulates transfers of energy and nutrients to higher trophic levels. In humid tropical forests that grow on P-depleted soils, the ability of microbes to concentrate P from their surroundings likely plays a critical role in P-retention and ultimately in forest productivity. Models predict that climate change will cause dramatic changes in rainfall patterns in the humid tropics and field studies have shown these changes can affect the redox state of tropical forest soils, influencing soil respiration and biogeochemical cycling. However, the responses of soil microorganisms to changing environmental conditions are not well known. Here, we incubated humid tropical soils under oxic or anoxic conditions with substrates differing in both C:P stoichiometry and lability, to assess how soil microorganisms respond to different redox regimes. We found that under oxic conditions, microbial C:P ratios were similar to the global optimal ratio (55:1), indicating most microbial cells can adapt to persistent aerated conditions in these soils. However, under anoxic conditions, the ability of soil microbes to acquire soil P declined and their C:P ratios shifted away from the optimal ratio. NanoSIMS elemental imaging of single cells extracted from soil revealed that under anoxic conditions, C:P ratios were above the microbial optimal value in 83% of the cells, in comparison to 41% under oxic conditions. These data suggest microbial growth efficiency switched from being energy limited under oxic conditions to P-limited under anoxic conditions, indicating that, microbial growth in low P humid tropical forests soils may be most constrained by P-limitation when conditions are oxygen-limited. We suggest that differential microbial responses to soil redox states could have important implications for productivity of humid tropical forests under future climate scenarios.
Bateman, H.L.; Nagler, P.L.; Glenn, E.P.
2013-01-01
The biocontrol agent, northern tamarisk beetle (Diorhabda carinulata), has been used to defoliate non-native saltcedar (Tamarix spp.) in USA western riparian systems since 2001. Biocontrol has the potential to impact biotic communities and climatic conditions in affected riparian areas. To determine the relationships between biocontrol establishment and effects on vegetation and climate at the plot and landscape scales, we measured temperature, relative humidity, foliage canopy, solar radiation, and used satellite imagery to assess saltcedar defoliation and evapotranspiration (ET) along the Virgin River in the Mojave Desert. Following defoliation solar radiation increased, daily humidity decreased, and maximum daily temperatures tended to increase. MODIS and Landsat satellite imagery showed defoliation was widespread, resulting in reductions in ET and vegetation indices. Because biocontrol beetles are spreading into new saltcedar habitats on arid western rivers, and the eventual equilibrium between beetles and saltcedar is unknown, it is necessary to monitor trends for ecosystem functions and higher trophic-level responses in habitats impacted by biocontrol.
Galindo, Nuria; Yubero, Eduardo
2017-01-01
The present work reports diurnal and nocturnal concentrations of water-soluble ions associated to PM 10 samples collected during the warm and cold seasons in the urban center of Elche (Southeastern Spain). Statistical differences between daytime and nighttime levels of PM 10 were only observed during winter. The lower concentrations during the night were most likely the result of a reduction in traffic-induced road dust resuspension, since nocturnal concentrations of calcium also exhibited a significant decrease compared to daytime levels. During the warm season, nitrate was the only component that showed a statistically significant increase from day to night. The lower nocturnal temperatures that prevent the thermal decomposition of ammonium nitrate and the formation of nitric acid favored by the higher relative humidity at night are the most probable reasons for this variation. The close relationship between nitrate formation and relative humidity during nighttime was supported by the results of the correlation analysis. The reaction of sulfuric and nitric acids with CaCO 3 occurred to a greater extent during daytime in summer.
Johnston, James D; Barney, Taylor P; Crandall, Justin H; Brown, Marinn A; Westover, Tarah R; Paulson, Sterling M; Smith, Madeleine S; Weber, K Scott
2018-01-02
House dust mites are typically absent in homes in arid and semiarid climates due to low humidity. Evaporative "swamp" cooling significantly increases indoor humidity in dry climates and is suspected of promoting dust mite survival in these regions. We investigated the prevalence and concentration of mite allergens in dust from low-income homes (N = 22) with evaporative coolers in Utah County, Utah. Overall, 15 homes (68.2%) were positive for either Der p 1 or Der f 1 in at least 1 location. Geometric mean allergen levels in mattresses were 0.107 and 0.087 ug/g dust for Der p 1 and Der f 1, respectively. In furniture, levels were 0.143 and 0.165 ug/g dust for Der p1 and Der f 1, respectively. The percentage of positive homes in this study was much higher than previously reported in larger homes with swamp coolers in the same community. These results suggest socioeconomic factors may play a role in dust mite allergen prevalence in homes with evaporative coolers in dry climates.
Temperature and Humidity Effects on Hospital Morbidity in Darwin, Australia.
Goldie, James; Sherwood, Steven C; Green, Donna; Alexander, Lisa
2015-01-01
Many studies have explored the relationship between temperature and health in the context of a changing climate, but few have considered the effects of humidity, particularly in tropical locations, on human health and well-being. To investigate this potential relationship, this study assessed the main and interacting effects of daily temperature and humidity on hospital admission rates for selected heat-relevant diagnoses in Darwin, Australia. Univariate and bivariate Poisson generalized linear models were used to find statistically significant predictors and the admission rates within bins of predictors were compared to explore nonlinear effects. The analysis indicated that nighttime humidity was the most statistically significant predictor (P < 0.001), followed by daytime temperature and average daily humidity (P < 0.05). There was no evidence of a significant interaction between them or other predictors. The nighttime humidity effect appeared to be strongly nonlinear: Hot days appeared to have higher admission rates when they were preceded by high nighttime humidity. From this analysis, we suggest that heat-health policies in tropical regions similar to Darwin need to accommodate the effects of temperature and humidity at different times of day. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Boundaries for biofilm formation: humidity and temperature.
Else, Terry Ann; Pantle, Curtis R; Amy, Penny S
2003-08-01
Environmental conditions which define boundaries for biofilm production could provide useful ecological information for biofilm models. A practical use of defined conditions could be applied to the high-level nuclear waste repository at Yucca Mountain. Data for temperature and humidity conditions indicate that decreases in relative humidity or increased temperature severely affect biofilm formation on three candidate canister metals.
The effect of relative humidity on germination of Sporangia of Phytophthora ramorum
USDA-ARS?s Scientific Manuscript database
Sporangia of three isolates of P. ramorum representing three different clonal lineages were subjected to relative humidity (RH) levels between 80 and 100% for exposure periods ranging from 1 to 24 h at 20°C in darkness. Airtight snap-lid plastic containers (21.5 x 14.5 x 5 cm) were used as humidity ...
NASA Astrophysics Data System (ADS)
Kraus, Michal; Juhásová Šenitková, Ingrid
2017-10-01
Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users’ health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [μg/m3]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [°C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10µg/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.
Tronick, E Z; Thomas, R B; Daltabuit, M
1994-08-01
The manta pouch--a caretaking practice of tightly swaddling and enclosing the infant in a set of cloths and blankets--and other caretaking practices are described for high-altitude resident (> 4,000 m) Quechua mother-infant pairs (N = 14). The manta pouch modifies the microenvironment inside the pouch so that, compared to the ambient environment, the temperature is higher and more stable, the humidity is higher, the partial pressure of O2 is lower, and stimulation levels are reduced. As the infant gets older, the characteristics of the pouch are modified such that the infant is increasingly exposed to ambient conditions. These caretaking practices may benefit the infant by buffering the infant from the multiple ecological stressors of high altitude, but they may also incur costs by exposing the infant to additional microenvironmental stressors (e.g., higher CO2 levels) and by reducing stimulation and limiting infant movement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ispen, J.; Deane, M.; Ingenito, F.E.
Comparison was made of industrial morbidity and absenteeism from upper respiratory disease with various measures of pollution and weather. Tests were conducted of workers visiting dispensaries of two plants in metropolitan Philadelphia and those working for the telephone company. Weekly morbidity was significantly correlated with temperature (r = -0.614), smoke shade (r = 0.556), particulate SO/sub 4/ (r = 0.289), and particulate matter (r = 0.264). Seasonal variation was in all variables. Pollution measures were inversely related to temperature. Particulate and SO/sub 4/ were inversely related to rainfall. SO/sub 4/ was inversely related to wind velocity. Daily correlations show day-of-weekmore » effect with lower morbidity and pollution on weekends. Higher prevalence/incidence ratio in winter was found. High morbidity was preceded by a week with low temperatures, high relative humidity, high wind velocity, and high pollutant levels, and accompanied by low temperatures, high relative humidity, and high wind.« less
Influence of atmospheric properties on detection of wood-warbler nocturnal flight calls
NASA Astrophysics Data System (ADS)
Horton, Kyle G.; Stepanian, Phillip M.; Wainwright, Charlotte E.; Tegeler, Amy K.
2015-10-01
Avian migration monitoring can take on many forms; however, monitoring active nocturnal migration of land birds is limited to a few techniques. Avian nocturnal flight calls are currently the only method for describing migrant composition at the species level. However, as this method develops, more information is needed to understand the sources of variation in call detection. Additionally, few studies examine how detection probabilities differ under varying atmospheric conditions. We use nocturnal flight call recordings from captive individuals to explore the dependence of flight call detection on atmospheric temperature and humidity. Height or distance from origin had the largest influence on call detection, while temperature and humidity also influenced detectability at higher altitudes. Because flight call detection varies with both atmospheric conditions and flight height, improved monitoring across time and space will require correction for these factors to generate standardized metrics of songbird migration.
Merello, Paloma; García-Diego, Fernando-Juan; Zarzo, Manuel
2012-11-28
Ariadne's house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.
Creep behavior of sweetgum OSB: effect of load level and relative humidity
J.H. Pu; R.C. Tang; Chung-Yun Hse
1994-01-01
Flexural creep behavior of laboratory-fabricated sweetgum oriented strandboard (OSB). under constnat (65% and 95%) and cyclic (65% 95% at a 96-hr. frequency) relative humidity (RH) conditions at 75 F (23.9 C) is presented. Two levels (4.5% and 6.5%) of resin content (RC) of phenol-formaldehyde were used in fabricating the test panels. Two load levels (20% and...
An XPS study on the impact of relative humidity on the aging of UO 2 powders
Donald, Scott B.; Dai, Zurong R.; Davisson, M. Lee; ...
2017-02-10
High resolution x-ray photoemission spectroscopy (XPS) was used to characterize the chemical speciation of high purity uranium dioxide (UO 2) powder samples following aging for periods of up to one year under controlled conditions with relative humidity ranging from 34% to 98%. A systematic shift to higher uranium oxidation states, and thus an increase in the mean uranium valence, was found to directly correlate with the dose of water received (i.e. the product of exposure time and relative humidity). Exposure duration was found to have a greater impact on sample aging than relative humidity. Lastly, the sample aged at 98%more » relative humidity was found to have unique structural differences for exposure time beyond 180 days when observed by scanning electron microscopy (SEM).« less
An XPS study on the impact of relative humidity on the aging of UO 2 powders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donald, Scott B.; Dai, Zurong R.; Davisson, M. Lee
High resolution x-ray photoemission spectroscopy (XPS) was used to characterize the chemical speciation of high purity uranium dioxide (UO 2) powder samples following aging for periods of up to one year under controlled conditions with relative humidity ranging from 34% to 98%. A systematic shift to higher uranium oxidation states, and thus an increase in the mean uranium valence, was found to directly correlate with the dose of water received (i.e. the product of exposure time and relative humidity). Exposure duration was found to have a greater impact on sample aging than relative humidity. Lastly, the sample aged at 98%more » relative humidity was found to have unique structural differences for exposure time beyond 180 days when observed by scanning electron microscopy (SEM).« less
XPS Investigation on Changes in UO 2 Speciation following Exposure to Humidity
Donald, Scott B.; Davisson, M. Lee; Nelson, Art J.
2016-04-27
High purity UO 2powder samples were subjected to accelerated aging under controlled conditions with relative humidity ranging from 34% to 98%. Characterization of the chemical speciation of the products was accomplished using X-ray photoelectron spectroscopy (XPS). A shift to higher uranium oxidation states was found to be directly correlated to increased relative humidity exposure. In addition, the relative abundance of O 2-, OH -, and H 2O was found to vary with exposure time. Therefore, it is expected that uranium oxide materials exposed to high relative humidity conditions during processing and storage would display a similar increase in average uraniummore » valence.« less
Nabeshima, T; Banno, S; Kameyama, T
1982-10-01
1. Changes in plasma glucose and corticosterone levels under an environment of high temperature and humidity similar to summers in Japan were investigated. 2. When mice were exposed to high temperature (30-40 degrees C) and humidity (70%), the plasma glucose levels increased with a short-term exposure and decreased with a long-term exposure compared to that of the control mice housed at room temperature (23 degrees C) and humidity (55%). 3. The magnitude of increase of plasma corticosterone levels depended on the degree of ambient temperature and the duration of exposure to the stressful conditions. The plasma corticosterone concentration was highest at 2 hr after initiation of the temperature stress and was reduced at 4 and 6 hr after the treatment: The plasma corticosterone had returned to the control level at 8 hr after the exposure. 4. The dexamethasone treatment inhibited the increase of plasma corticosterone in stress-mice. 5. These results suggest that the response of the plasma corticosterone is a better index than that of glucose for estimation of stress-degree.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systemsmore » operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerrigan, P.; Norton, P.
This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systemsmore » operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.« less
de Oliveira, Sergius A R; Lucio, Lorena M C; Modolo, Norma S P; Hayashi, Yoko; Braz, Mariana G; de Carvalho, Lídia R; Braz, Leandro G; Braz, José Reinaldo C
2017-01-01
During anesthesia, as compared with intensive care, the time of the tracheal intubation is much shorter. An inhaled gas minimum humidity of 20 mgH2O.L-1 is recommended to reduce the deleterious effects of dry gas on the airways during anesthesia with tracheal intubation. The Fabius GS Premium® anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat gases in the breathing circuit. A heat and moisture exchanger (HME) is used to further heat and humidify the inhaled gas. The humidity of the gases in the breathing circuit is influenced by the ambient temperature. We compared the humidity of the inhaled gases from a low-flow Fabius anesthesia workstation with or without thermal insulation (TI) of the breathing circuit and with or without an HME. We conducted a prospective randomized trial in 41 adult female patients who underwent elective abdominal surgery. The patients were allocated into four groups according to the devices used to ventilate their lungs using a Dräger Fabius anesthesia workstation with a low gas flow (1 L.min-1): control, with TI, with an HME or with TI and an HME (TIHME). The mean temperature and humidity of the inhaled gases were measured during 2-h after connecting the patients to the breathing circuit. The mean inhaled gas temperature and absolute humidity were higher in the HME (29.2±1.3°C; 28.1±2.3 mgH2O·L-1) and TIHME (30.1±1.2°C; 29.4±2.0 mgH2O·L-1) groups compared with the control (27.5±1.0°C; 25.0±1.8 mgH2O·L-1) and TI (27.2±1.1°C; 24.9±1.8 mgH2O·L-1) groups (P = 0.003 and P<0.001, respectively). The low-flow Fabius GS Premium breathing circuit provides the minimum humidity level of inhaled gases to avoid damage to the tracheobronchial epithelia during anesthesia. TI of the breathing circuit does not increase the humidity of the inhaled gases, whereas inserting an HME increases the moisture of the inhaled gases closer to physiological values.
Consales, Marco; Berruti, Gaia; Borriello, Anna; Giordano, Michele; Buontempo, Salvatore; Breglio, Giovanni; Makovec, Alajos; Petagna, Paolo; Cusano, Andrea
2014-07-15
This Letter deals with a feasibility analysis for the development of radiation-tolerant fiber-optic humidity sensors based on long-period grating (LPG) technology to be applied in high-energy physics (HEP) experiments currently running at the European Organization for Nuclear Research (CERN). In particular, here we propose a high-sensitivity LPG sensor coated with a finely tuned titanium dioxide (TiO₂) thin layer (~100 nm thick) through the solgel deposition method. Relative humidity (RH) monitoring in the range 0%-75% and at four different temperatures (in the range -10°C-25°C) was carried out to assess sensor performance in real operative conditions required in typical experiments running at CERN. Experimental results demonstrate the very high RH sensitivities of the proposed device (up to 1.4 nm/% RH in correspondence to very low humidity levels), which turned out to be from one to three orders of magnitude higher than those exhibited by fiber Bragg grating sensors coated with micrometer-thin polyimide overlays. The radiation tolerance capability of the TiO₂-coated LPG sensor is also investigated by comparing the sensing performance before and after its exposure to a 1 Mrad dose of γ-ionizing radiation. Overall, the results collected demonstrate the strong potential of the proposed technology with regard to its future exploitation in HEP applications as a robust and valid alternative to the commercial (polymer-based) hygrometers currently used.
Adkar, Dattatraya; Adhyapak, Parag; Mulik, Uttamrao; Jadkar, Sandesh; Vutova, Katia; Amalnerkar, Dinesh
2018-05-01
SnS nanostructured materials have attracted enormous interest due to their important properties and potential application in low cost solar energy conversion systems and optical devices. From the perspective of SnS based device fabrication, we offer single-stroke in-situ technique for the generation of Sn based sulphide and oxide nanostructures inside the polymer network via polymer-inorganic solid state reaction route. In this method, polyphenylene sulphide (PPS)-an engineering thermoplastic-acts as chalcogen source as well as stabilizing matrix for the resultant nano products. Typical solid state reaction was accomplished by simply heating the physical admixtures of the tin salts (viz. tin acetate/tin chloride) with PPS at the crystalline melting temperature (285 °C) of PPS in inert atmosphere. The synthesized products were characterized by using various physicochemical characterization techniques. The prima facie observations suggest the concurrent formation of nanocrystalline SnS with extraneous oxide phase. The TEM analysis revealed formation of nanosized particles of assorted morphological features with polydispersity confined to 5 to 50 nm. However, agglomerated particles of nano to submicron size were also observed. The humidity sensing characterization of these nanocomposites was also performed. The resistivity response with the level of humidity (20 to 85% RH) was compared for these nanocomposites. The linear response was obtained for both the products. Nevertheless, the nanocomposite product obtained from acetate precursor showed higher sensitivity towards the humidity than that of one prepared from chloride precursor.
Solid state stability and solubility of triethylenetetramine dihydrochloride.
Henriet, Théo; Gana, Inès; Ghaddar, Carine; Barrio, Maria; Cartigny, Yohann; Yagoubi, Najet; Do, Bernard; Tamarit, Josep-Lluis; Rietveld, Ivo B
2016-09-10
The API triethylenetetramine dihydrochloride used as an alternative treatment of Wilson's disease is sensitive to water and it exhibits polymorphism. As this may become an issue for the drug formulation, the physical stability has been studied by differential scanning calorimetry, high-pressure thermal analysis, dynamic vapor sorption, and X-ray diffraction as a function of temperature. In addition, high-pressure liquid chromatography and mass spectrometry have been used to study the purity and chemical stability of the API. A pressure-temperature phase diagram of the pure compound has been constructed and it can be concluded that form II is monotropic in relation to form I, which is the only stable solid. The solubilities of the different solid forms have been determined with the help of a temperature - composition phase diagram. The API is very soluble, at 20° C about 10% of the saturated solution with respect to the dihydrate consists of API and the solubility of the pure form I is twice as high. Moreover, it has been shown that at 20°C, a relative humidity above 40% induces the formation of the dihydrate and at 70% a saturated solution appears. At higher temperatures, the formation of the dihydrate appears at lower relative humidity values. A clear link has been established between the API's chemical stability, its physical stability and the relative humidity in the air. Humidity levels above 40% are detrimental to the quality of the API. Copyright © 2016 Elsevier B.V. All rights reserved.
Metal organic frameworks enhanced graphene oxide electrode for humidity sensor
NASA Astrophysics Data System (ADS)
Zhang, Wen; Meng, Siyu; Wang, Hui; He, Yongning
2018-03-01
Copper benzene-1,3,5-tricarboxylate (Cu-BTC), a typical metal organic framework, is deposited on the graphene oxide (GO) film to prepare a resistance humidity sensor (Cu- BTC/GO) for improving humidity sensing. The characteristics of Cu-BTC, GO and Cu- BTC/GO were measured by scanning electron microscopy (SEM), X-ray diffraction (XRD), nitrogen isotherm adsorption and electrochemical impedance spectroscopy (EIS). The humidity sensing properties of the Cu-BTC/GO were investigated in detail. The obtained Cu-BTC/GO demonstrates good sensitivity and repeatability over 11%-85% relative humidity (RH) measurements. The Cu-BTC/GO coated device shows high normalized response (S) value (6200%), which is much higher than that of pure GO coated device. Sensing mechanism of Cu- BTC/GO is discussed based on different RH and the results indicate that moderate amounts of Cu-BTC deposition can enhance sensing abilities of GO. High specific surface area and interfacial conductivity are crucial factors to fabricate humidity sensors with high performance.
NASA Astrophysics Data System (ADS)
Tripathi, P.; Behera, M. D.; Behera, S. K.; Sahu, N.
2016-12-01
Investigating the impact of climate variables on net primary productivity is crucial to evaluate the ecosystem health and the status of forest type response to climate change. The objective of this paper is (1) to analyze the spatio-temporal pattern of net primary productivity (NPP) in a tropical forest ecosystem situated along the Himalayan foothills in India and (2) to investigate the continuous and delayed effects of climatic variables. Weapplied simple Monteith equation based Light use efficiency model for two dominant plant functional types; sal (Shorea robusta) forest and teak (Tectona grandis) plantation to estimate the NPP for a decadal period from 2001 to 2010. The impact of climate variables on NPP for these 10 years was seen by applying two correlation analyses; generalized linear modelling (GLM) and time lag correlation approach.The impact of different climate variables was observed to vary throughout the study period.A decline in mean NPP during 2002-2003, 2005 and 2008 to 2010 could be attributed to drought, increased vapour pressure deficit, and decreased humidity and solar radiation. In time lag correlation analysis, precipitation and humidity were observed to be the major variables affecting NPP; whereas combination of temperature, humidity and VPD showed dominant effect on NPP in GLM. Shorea robusta forest showed slightly higher NPP than that of Tectona grandis plantation throughout the study period. Highest decrease in NPP was observed during 2010,pertaining to lower solar radiation, humidity and precipitation along with increased VPD.Higher gains in NPP by sal during all years indicates their better adaptability to climate compared to teak. Contribution of different climatic variables through some link process is revealed in statistical analysis clearly indicates the co-dominance of all the variables in explaining NPP. Lacking of site specific meteorological observations and microclimate put constraint on broad level analyses.
AuNPs Hybrid Black ZnO Nanorods Made by a Sol-Gel Method for Highly Sensitive Humidity Sensing
Zhang, Min; Lin, Cunchong; Zhang, Jun
2018-01-01
A highly sensitive self-powered humidity sensor has been realized from AuNPs hybrid black zinc oxide (ZnO) nanorods prepared through a sol-gel method. XRD pattern reveals that both ZnO and ZnO/AuNPs exhibit a wurtzite structure. ZnO/AuNPs nanorods grow in a vertical alignment, which possesses high uniformity and forms dense arrays with a smaller diameter than that of ZnO nanoparticles. All ZnO/AuNPs and pure black ZnO show lower band gap energy than the typically reported 3.34 eV of pure ZnO. Furthermore, the band gap of ZnO/AuNPs nanocomposites is effectively influenced by the amount of AuNPs. The humidity sensing tests clearly prove that all the ZnO/AuNPs humidity sensors exhibit much higher response than that of ZnO sensors, and the sensitivity of such ZnO/AuNPs nanorods (6 mL AuNPs) display a change three orders higher than that of pure ZnO with relative humidity (RH) ranging from 11% to 95% at room temperature. The response and recovery time of the ZnO/AuNPs are 5.6 s and 32.4 s, respectively. This study of the construction of semiconductor/noble metal sensors provides a rational way to control the morphology of semiconductor nanomaterials and to design a humidity sensor with high performance. PMID:29342860
AuNPs Hybrid Black ZnO Nanorods Made by a Sol-Gel Method for Highly Sensitive Humidity Sensing.
Zhang, Hongyan; Zhang, Min; Lin, Cunchong; Zhang, Jun
2018-01-13
A highly sensitive self-powered humidity sensor has been realized from AuNPs hybrid black zinc oxide (ZnO) nanorods prepared through a sol-gel method. XRD pattern reveals that both ZnO and ZnO/AuNPs exhibit a wurtzite structure. ZnO/AuNPs nanorods grow in a vertical alignment, which possesses high uniformity and forms dense arrays with a smaller diameter than that of ZnO nanoparticles. All ZnO/AuNPs and pure black ZnO show lower band gap energy than the typically reported 3.34 eV of pure ZnO. Furthermore, the band gap of ZnO/AuNPs nanocomposites is effectively influenced by the amount of AuNPs. The humidity sensing tests clearly prove that all the ZnO/AuNPs humidity sensors exhibit much higher response than that of ZnO sensors, and the sensitivity of such ZnO/AuNPs nanorods (6 mL AuNPs) display a change three orders higher than that of pure ZnO with relative humidity (RH) ranging from 11% to 95% at room temperature. The response and recovery time of the ZnO/AuNPs are 5.6 s and 32.4 s, respectively. This study of the construction of semiconductor/noble metal sensors provides a rational way to control the morphology of semiconductor nanomaterials and to design a humidity sensor with high performance.
NASA Astrophysics Data System (ADS)
Chaiyabutr, N.; Chanpongsang, S.; Suadsong, S.
2008-09-01
The aim of this study was to determine how evaporative cooling modifies body function with respect to water metabolism and other variables relevant to milk synthesis in crossbred cattle. The study was conducted on two groups of 0.875HF:0.125RS crossbred Holstein cattle (87.5%) housed in an open-sided barn with a tiled roof (non-cooled animals) and in a close-sided barn under an evaporative cooling system (cooled animals). The maximum ambient temperature and relative humidity for the non-cooled group were 33°C and 61%, with the corresponding values for the evaporatively cooled barn being 28°C and 84%, respectively. The temperature humidity index (THI) of under non-cooled conditions was higher ( P < 0.05) than that in the cooled barn. Rectal temperatures and respiration rates of non-cooled animals were higher ( P < 0.05) than those of cooled animals. Daily dry matter intake (DMI) of cooled animals was higher while water intakes were lower ( P < 0.05) than those of non-cooled animals. The mean absolute values of plasma volume, blood volume, and extracellular fluid (ECF) of cooled animals were significantly higher ( P < 0.05) than those of non-cooled animals throughout all stages of lactation. Milk yields of cooled animals were higher by 42%, 36% and 79% on average than those of non-cooled animals during early-, mid- and late-lactation, respectively. The decline in milk yields as lactation advances was markedly apparent in late-lactating non-cooled animals, while no significant changes in milk composition at different stages of lactation were observed in either group. Mean arterial plasma concentrations, arteriovenous concentration differences (A-V differences) and the extraction ratio across the mammary gland for acetate, glucose and triglyceride of cooled animals were not significantly different compared with values for non-cooled animals. No differences were seen in plasma hormonal levels for triiodotyronine (T3) and insulin-like growth factor-1 (IGF-1), but plasma cortisol and thyroxine (T4) levels tended to be lower in non-cooled animals. This study suggests that low cooling temperature accompanied by high humidity influences a galactopoietic effect, in part through increases in ECF, blood volume and plasma volume in association with an increase in DMI, which partitions the distribution of nutrients to the mammary gland for milk synthesis. Cooled animals were unable to maintain high milk yield as lactation advances even though a high level of body fluids was maintained during long-term cooled exposure. The decline in milk yield, coinciding with a decrease in net energy for lactation as lactation advances, could be attributed to a local change within the mammary gland.
Boundaries for Biofilm Formation: Humidity and Temperature
Else, Terry Ann; Pantle, Curtis R.; Amy, Penny S.
2003-01-01
Environmental conditions which define boundaries for biofilm production could provide useful ecological information for biofilm models. A practical use of defined conditions could be applied to the high-level nuclear waste repository at Yucca Mountain. Data for temperature and humidity conditions indicate that decreases in relative humidity or increased temperature severely affect biofilm formation on three candidate canister metals. PMID:12902302
Rujivipat, Soravoot; Bodmeier, Roland
2012-05-01
Enteric polymers such as cellulose esters (cellulose acetate phthalate, hydroxypropylmethylcellulose acetate succinate) and methacrylic acid-acrylate copolymers (Eudragit® L100-55 and S100) are quite brittle in the dry state and thus not suitable as pellet coatings for compression into tablets. The objective of this study was to investigate the role of humidity treatment for moisture plasticization in order to successfully compress the enterically coated pellets. The mechanical properties of Eudragit® L100-55 improved dramatically, while the properties of the other enteric polymers showed only minor changes after storage at higher humidity. The significant increase in flexibility of the Eudragit® L film was caused by hydration/plasticization; its elongation value changed from approx. 3% in the dry state to approx. 140% at the higher storage humidity. Storage at 84% relative humidity resulted in comparable release profiles of compressed and uncompressed pellets. The glass transition temperature of Eudragit® L films decreased below the compression temperature (room temperature) at storage humidities between 75% and 84%. The glass transition relative humidity leading to a change from the glassy to the rubbery state was determined by dynamic vapor sorption (DVS) to be 76.8%. Moisture resulted in superior plasticization for Eudragit® L than the conventional plasticizer triethyl citrate. The improved compressibility of high humidity treated Eudragit® L-coated pellets was also shown with single pellet compression data as indicated by an increased crushing force and deformation. In conclusion, moisture plasticization was a highly effective tool to enable the successful compression of pellets coated with the brittle enteric polymer Eudragit® L. Copyright © 2012 Elsevier B.V. All rights reserved.
Effects of wind application on thermal perception and self-paced performance.
Teunissen, L P J; de Haan, A; de Koning, J J; Daanen, H A M
2013-07-01
Physiological and perceptual effects of wind cooling are often intertwined and have scarcely been studied in self-paced exercise. Therefore, we aimed to investigate (1) the independent perceptual effect of wind cooling and its impact on performance and (2) the responses to temporary wind cooling during self-paced exercise. Ten male subjects completed four trials involving 15 min standardized incremental intensity cycling, followed by a 15-km self-paced cycling time trial. Three trials were performed in different climates inducing equivalent thermal strain: hot humid with wind (WIND) and warm humid (HUMID) and hot dry (DRY) without wind. The fourth trial (W3-12) was equal to HUMID, except that wind cooling was unexpectedly provided during kilometers 3-12. Physiological, perceptual and performance parameters were measured. Subjects felt generally cooler during the WIND than the HUMID and DRY trials, despite similar heart rate, rectal and skin temperatures and a WBGT of ~4 °C higher. The cooler thermal sensation was not reflected in differences in thermal comfort or performance. Comparing W3-12 to HUMID, skin temperature was 1.47 ± 0.43 °C lower during the wind interval, leading to more favorable ratings of perceived exertion, thermal sensation and thermal comfort. Overall, power output was higher in the W3-12 than the HUMID-trial (256 ± 29 vs. 246 ± 22 W), leading to a 67 ± 48 s faster finish time. In conclusion, during self-paced exercise in the heat, wind provides immediate and constant benefits in physiological strain, thermal perception and performance. Independent of physiological changes, wind still provides a greater sensation of coolness, but does not impact thermal comfort or performance.
Effect of humidity on fretting wear of several pure metals
NASA Technical Reports Server (NTRS)
Goto, H.; Buckley, D. H.
1984-01-01
Fretting wear experiments with several pure metals were conducted in air at various relative humidity levels. The materials used were iron, aluminum, copper, silver, chromium, titanium, and nickel. Each pure metal had a maximum fretting wear volume at a specific humidity level RH sub max that was not dependent on mechanical factors such as contact load, fretting amplitude, and frequency in the ranges studied. The weight loss due to fretting wear at RH sub max for each pure metal decreased with increasing heat of oxygen adsorption on the metal, indicating that adhesive wear dominated at RH sub max.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
NASA Astrophysics Data System (ADS)
Conseil-Gudla, Hélène; Jellesen, Morten S.; Ambat, Rajan
2017-02-01
Corrosion reliability is a serious issue today for electronic devices, components, and printed circuit boards (PCBs) due to factors such as miniaturization, globalized manufacturing practices which can lead to process-related residues, and global usage effects such as bias voltage and unpredictable user environments. The investigation reported in this paper focuses on understanding the synergistic effect of such parameters, namely contamination, humidity, PCB surface finish, pitch distance, and potential bias on leakage current under different humidity levels, and electrochemical migration probability under condensing conditions. Leakage currents were measured on interdigitated comb test patterns with three different types of surface finish typically used in the electronics industry, namely gold, copper, and tin. Susceptibility to electrochemical migration was studied under droplet conditions. The level of base leakage current (BLC) was similar for the different surface finishes and NaCl contamination levels up to relative humidity (RH) of 65%. A significant increase in leakage current was found for comb patterns contaminated with NaCl above 70% to 75% RH, close to the deliquescent RH of NaCl. Droplet tests on Cu comb patterns with varying pitch size showed that the initial BLC before dendrite formation increased with increasing NaCl contamination level, whereas electrochemical migration and the frequency of dendrite formation increased with bias voltage. The effect of different surface finishes on leakage current under humid conditions was not very prominent.
2014-01-01
Background Climate change can affect the activity and distribution of species, including pathogens and parasites. The densities and distribution range of the sheep tick (Ixodes ricinus) and it’s transmitted pathogens appears to be increasing. Thus, a better understanding of questing tick densities in relation to climate and weather conditions is urgently needed. The aim of this study was to test predictions regarding the temporal pattern of questing tick densities at two different elevations in Norway. We predict that questing tick densities will decrease with increasing elevations and increase with increasing temperatures, but predict that humidity levels will rarely affect ticks in this northern, coastal climate with high humidity. Methods We described the temporal pattern of questing tick densities at ~100 and ~400 m a.s.l. along twelve transects in the coastal region of Norway. We used the cloth lure method at 14-day intervals during the snow-free season to count ticks in two consecutive years in 20 m2 plots. We linked the temporal pattern of questing tick densities to local measurements of the prevailing weather. Results The questing tick densities were much higher and the season was longer at ~100 compared to at ~400 m a.s.l. There was a prominent spring peak in both years and a smaller autumn peak in one year at ~100 m a.s.l.; but no marked peak at ~400 m a.s.l. Tick densities correlated positively with temperature, from low densities <5°C, then increasing and levelling off >15-17°C. We found no evidence for reduced questing densities during the driest conditions measured. Conclusions Tick questing densities differed even locally linked to elevation (on the same hillside, a few kilometers apart). The tick densities were strongly hampered by low temperatures that limited the duration of the questing seasons, whereas the humidity appeared not to be a limiting factor under the humid conditions at our study site. We expect rising global temperatures to increase tick densities and lead to a transition from a short questing season with low densities in the current cold and sub-optimal tick habitats, to longer questing seasons with overall higher densities and a marked spring peak. PMID:24725997
Lellouche, François; Qader, Siham; Taillé, Solenne; Lyazidi, Aissam; Brochard, Laurent
2014-05-01
During invasive mechanical ventilation, inspired gases must be humidified. We previously showed that high ambient temperature greatly impaired the hygrometric performance of heated wire-heated humidifiers. The aim of this bench and clinical study was to assess the humidification performance of passive and active heat and moisture exchangers (HMEs) and the impact of ambient temperature and ventilator settings. We first tested on the bench a device with passive and active humidification properties (Humid-Heat, Teleflex), and 2 passive hydrophobic/hygroscopic HMEs (Hygrobac and Hygrobac S, Tyco Healthcare). The devices were tested at 3 different ambient temperatures (from 22 to 30 °C), and at 2 minute ventilation settings (10 and 20 L/min). Inspired gas hygrometry was measured at the Y-piece with the psychrometric method. In addition to the bench study, we measured the hygrometry of inspired gases in 2 different clinical studies. In 15 mechanically ventilated patients, we evaluated Humid-Heat at different settings. Additionally, we evaluated Humid-Heat and compared it with Hygrobac in a crossover study in 10 patients. On the bench, with the Hygrobac and Hygrobac S the inspired absolute humidity was ∼ 30 mg H2O/L, and with the Humid-Heat, slightly < 35 mg H2O/L. Ambient temperature and minute ventilation did not have a clinically important difference on the performance of the tested devices. During the clinical evaluation, Humid-Heat provided inspired humidity in a range from 28.5 to 42.0 mg H2O/L, depending on settings, and was only weakly influenced by the patient's body temperature. In this study both passive and active HMEs had stable humidification performance with negligible influence of ambient temperature and minute ventilation. This contrasts with previous findings with heated wire-heated humidifiers. Although there are no clear data demonstrating that higher humidification impacts outcomes, it is worth noting that humidity was significantly higher with the active HME.
Creep behavior of sweetgum OSB: Effect of load level and relative humidity
J.H. Pu; R.C. Tang; Chung-Yun Hse
1994-01-01
flexural creep behavior of laboratory-fabricated sweetgum oriented strandboard (0SB), under constant (65% and 95%) and cyclic (65% ↔ 95% at a 96-hr. frequency) relative humidity (RH) conditions at 75°F(23.9°C) is presented. Two levels (4.5% and 6.5%) of resin content (RC) of phenol-formaldehyde were used in fabricating the test panels. Two load levels (20%...
Changes of pressure and humidity affect olfactory function.
Kuehn, Michael; Welsch, Heiko; Zahnert, Thomas; Hummel, Thomas
2008-03-01
The present study aimed at investigating the question whether olfactory function changes in relation to barometric pressure and humidity. Using climate chambers, odor threshold and discrimination for butanol were tested in 75 healthy volunteers under hypobaric and hyperbaric, and different humidity conditions. Among other effects, olfactory sensitivity at threshold level, but not suprathreshold odor discrimination, was impaired in a hypobaric compared to a hyperbaric milieu, and thresholds were lower in humid, compared to relatively dry conditions. In conclusion, environmental conditions modulate the sense of smell, and may, consecutively, influence results from olfactory tests.
Tanaka, Yukari; Iwata, Sachiko; Kinoshita, Masahiro; Tsuda, Kennosuke; Tanaka, Shoichiro; Hara, Naoko; Shindou, Ryota; Harada, Eimei; Kijima, Ryouji; Yamaga, Osamu; Ohkuma, Hitoe; Ushijima, Kazuo; Sakamoto, Teruo; Yamashita, Yushiro; Iwata, Osuke
2017-01-01
For cooled newborn infants, humidifier settings for normothermic condition provide excessive gas humidity because absolute humidity at saturation is temperature-dependent. To assess humidification of respiratory gases in patients who underwent moderate therapeutic hypothermia at a paediatric/adult intensive care unit, 6 patients were studied over 9 times. Three humidifier settings, 37-default (chamber-outlet, 37°C; Y-piece, 40°C), 33.5-theoretical (chamber-outlet, 33.5°C; Y-piece, 36.5°C), and 33.5-adjusted (optimised setting to achieve saturated vapour at 33.5°C using feedback from a thermohygrometer), were tested. Y-piece gas temperature/humidity and the incidence of high (>40.6 mg/L) and low (<32.9 mg/L) humidity relative to the target level (36.6 mg/L) were assessed. Y-piece gas humidity was 32.0 (26.8-37.3), 22.7 (16.9-28.6), and 36.9 (35.5-38.3) mg/L {mean (95% confidence interval)} for 37-default setting, 33.5-theoretical setting, and 33.5-adjusted setting, respectively. High humidity was observed in 1 patient with 37-default setting, whereas low humidity was seen in 5 patients with 37-default setting and 8 patients with 33.5-theoretical setting. With 33.5-adjusted setting, inadequate Y-piece humidity was not observed. Potential risks of the default humidifier setting for insufficient respiratory gas humidification were highlighted in patients cooled at a paediatric/adult intensive care unit. Y-piece gas conditions can be controlled to the theoretically optimal level by adjusting the setting guided by Y-piece gas temperature/humidity.
Tanaka, Yukari; Iwata, Sachiko; Kinoshita, Masahiro; Tsuda, Kennosuke; Tanaka, Shoichiro; Hara, Naoko; Shindou, Ryota; Harada, Eimei; Kijima, Ryouji; Yamaga, Osamu; Ohkuma, Hitoe; Ushijima, Kazuo; Sakamoto, Teruo; Yamashita, Yushiro
2017-01-01
For cooled newborn infants, humidifier settings for normothermic condition provide excessive gas humidity because absolute humidity at saturation is temperature-dependent. To assess humidification of respiratory gases in patients who underwent moderate therapeutic hypothermia at a paediatric/adult intensive care unit, 6 patients were studied over 9 times. Three humidifier settings, 37-default (chamber-outlet, 37°C; Y-piece, 40°C), 33.5-theoretical (chamber-outlet, 33.5°C; Y-piece, 36.5°C), and 33.5-adjusted (optimised setting to achieve saturated vapour at 33.5°C using feedback from a thermohygrometer), were tested. Y-piece gas temperature/humidity and the incidence of high (>40.6 mg/L) and low (<32.9 mg/L) humidity relative to the target level (36.6 mg/L) were assessed. Y-piece gas humidity was 32.0 (26.8–37.3), 22.7 (16.9–28.6), and 36.9 (35.5–38.3) mg/L {mean (95% confidence interval)} for 37-default setting, 33.5-theoretical setting, and 33.5-adjusted setting, respectively. High humidity was observed in 1 patient with 37-default setting, whereas low humidity was seen in 5 patients with 37-default setting and 8 patients with 33.5-theoretical setting. With 33.5-adjusted setting, inadequate Y-piece humidity was not observed. Potential risks of the default humidifier setting for insufficient respiratory gas humidification were highlighted in patients cooled at a paediatric/adult intensive care unit. Y-piece gas conditions can be controlled to the theoretically optimal level by adjusting the setting guided by Y-piece gas temperature/humidity. PMID:28512388
N95 filtering facepiece respirator deadspace temperature and humidity.
Roberge, Raymond J; Kim, Jung-Hyun; Benson, Stacey
2012-01-01
The objective of this study was to determine the levels of heat and humidity that develop within the deadspace of N95 filtering facepiece respirators (N95 FFR). Seventeen subjects wore two models each of N95 FFR and N95 FFR with an exhalation valve (N95 FFR/EV) while exercising on a treadmill at a low-moderate work rate for 1 and 2 hr in a temperate ambient environment. FFR deadspace temperature and relative humidity were monitored by a wireless sensor housed within the FFR. Each FFR was weighed pre- and post-testing to determine moisture retention. After 1 hr, FFR deadspace temperature and humidity were markedly elevated above ambient levels, and the FFR deadspace mean apparent heat index was 54°C. N95 FFR/EV use resulted in significantly lower deadspace temperatures than N95 FFR (p = 0.01), but FFR deadspace humidity levels were not significantly different (p = 0.32). Compared with the first hour of use, no significant increase in FFR deadspace heat and humidity occurred over the second hour. FFR mean moisture retention was < 0.3 grams over 2 hr. N95 FFR/EV offer a significant advantage in deadspace heat dissipation over N95 FFR at a low-moderate work rate over 1 hr of continuous use but offered no additional benefit in humidity amelioration. Moisture retention in N95 FFR and N95 FFR/EV is minimal after 2 hr of use. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a file containing N95 filtering facepiece respirator deadspace mean RH and temperature recordings for 17 subjects treadmill exercising at 5.6 Km/H over 1 hour.].
Paper as Active Layer in Inkjet-Printed Capacitive Humidity Sensors
Gaspar, Cristina; Olkkonen, Juuso; Passoja, Soile; Smolander, Maria
2017-01-01
An inkjet-printed relative humidity sensor based on capacitive changes which responds to different humidity levels in the environment is presented in this work. The inkjet-printed silver interdigitated electrodes configuration on the paper substrate allowed for the fabrication of a functional proof-of-concept of the relative humidity sensor, by using the paper itself as a sensing material. The sensor sensitivity in terms of relative humidity changes was calculated to be around 2 pF/RH %. The response time against different temperature steps from 3 to 85 °C was fairly constant (about 4–5 min), and it was considered fast for the aimed application, a smart label. PMID:28640182
Disposable condenser humidifiers in intensive care.
Oh, T E; Thompson, W R; Hayward, D R
1981-11-01
Two disposable condenser humidifiers were evaluated in nine ventilated intensive care patients. The Portex "Humid Vent" delivered end-inspired absolute humidities of 22--26.3 g/m3 at end-inspired temperatures of 27--28.3 degrees C. Corresponding humidities and temperatures with the Servo "Humidifier 150" were higher and were constant, at 27.7--29 g/m3 and 29.3--29.7 degrees C respectively. These disposable devices can be used for humidification in intensive care, but only for patients breathing room air, or on a short term basis.
NASA Astrophysics Data System (ADS)
Kitahara, Tatsumi; Nakajima, Hironori; Okamura, Kosuke
2015-06-01
Gas diffusion layers (GDLs) coated with a hydrophobic microporous layer (MPL) composed of carbon black and polytetrafluoroethylene (PTFE) have been commonly used to improve the water management characteristics of polymer electrolyte fuel cells (PEFCs). However, the hydrophobic MPL coated GDL designed to prevent dehydration of the membrane under low humidity conditions is generally inferior at reducing flooding under high humidity conditions. It is therefore important to develop a robust MPL coated GDL that can enhance the PEFC performance regardless of the humidity conditions. In the present study, a GDL coated with an MPL containing hydrophilic carbon nanotubes (CNTs) was developed. The less hydrophobic pores incorporating CNTs are effective at conserving the membrane humidity under low humidity conditions. The MPL with CNTs is also effective at expelling excess water from the catalyst layer while maintaining oxygen flow pathways from the GDL substrate, allowing the mean flow pore diameter to be decreased to 2 μm without reducing the ability of the MPL to prevent flooding under high humidity conditions. An MPL coated GDL with a CNT content of 4 mass% exhibits significantly higher performance under both low and high humidity conditions than a hydrophobic MPL coated GDL.
1998-02-01
diet of higher trophic level species, such as raptors. Ord’s Kangaroo Rat (Dipodomys ordii). The Ord’s kangaroo rat is chiefly a nocturnal mammal...sandy soils. The entrances of these burrow systems are plugged during the day to maintain humidity and coolness. The kangaroo rat can obtain...sufficient quantities of water from the metabolism of food in their diet, but will drink water when it is available. TSK 0003/SWERA/Rev Final Rpt/November
Moisture sorption by cellulose powders of varying crystallinity.
Mihranyan, Albert; Llagostera, Assumpcio Piñas; Karmhag, Richard; Strømme, Maria; Ek, Ragnar
2004-01-28
Moisture in microcrystalline cellulose may cause stability problems for moisture sensitive drugs. The aim of this study was to investigate the influence of crystallinity and surface area on the uptake of moisture in cellulose powders. Powders of varying crystallinity were manufactured, and the uptake of moisture was investigated at different relative humidities. The structure of the cellulose powders was characterized by X-ray diffraction, BET surface area analysis, and scanning electron microscopy. Moisture uptake was directly related to the cellulose crystallinity and pore volume: Cellulose powders with higher crystallinity showed lower moisture uptake at relative humidities below 75%, while at higher humidities the moisture uptake could be associated with filling of the large pore volume of the cellulose powder of highest crystallinity. In conclusion, the structure of cellulose should be thoroughly considered when manufacturing low moisture grades of MCC.
Echechipía, S; Ventas, P; Audícana, M; Urrutia, I; Gastaminza, G; Polo, F; Fernández de Corres, L
1995-06-01
We present the results of allergen content evaluation in 80 dust samples from 31 homes of atopic patients from two climatic areas (humid and subhumid), collected in two seasons of the year (autumn and winter). Monoclonal antibody-based immunoassays were used to quantify Der p 1, Der f 1, Der 2, Lep d 1, and Fel d 1. The results were compared according to climate, season, and the type of sensitization (Pyroglyphidae mites, storage mites, or grass pollens). We underline the predominance of Dermatophagoides pteronyssinus (89% of samples) over D. farinae (16% of samples) in our environment. Der p 1 rates were higher in the humid area (Mann-Whitney P < 0.001), especially in the autumn (Wilcoxon P < 0.05). Lep d 1 was detected in 23% of samples and Lep d 1 levels were higher in the homes of patients sensitized to storage mites (Mann-Whitney P < 0.05), whereas this allergen was not detected in the homes of pollen-allergic patients. Fel d 1 was detected in nine of the 31 homes (16% of samples) although there was a cat in only one home.
Seasonal contrasts in the response of coffee ants to agroforestry shade-tree management.
Teodoro, A V; Sousa-Souto, L; Klein, A-M; Tscharntke, T
2010-12-01
In many tropical landscapes, agroforestry systems are the last forested ecosystems, providing shade, having higher humidity, mitigating potential droughts, and possessing more species than any other crop system. Here, we tested the hypothesis that higher levels of shade and associated humidity in agroforestry enhance coffee ant richness more during the dry than rainy season, comparing ant richness in 22 plots of three coffee agroforestry types in coastal Ecuador: simple-shade agroforests (intensively managed with low tree species diversity), complex-shade agroforests (extensively managed with intermediate tree species diversity) and abandoned coffee agroforests (abandoned for 10-15 yr and resembling secondary forests). Seasonality affected responses of ant richness but not composition to agroforestry management, in that most species were observed in abandoned coffee agroforests in the dry season. In the rainy season, however, most species were found in simple-shade agroforests, and complex agroforestry being intermediate. Foraging coffee ants species composition did not change differently according to agroforestry type and season. Results show that shade appears to be most important in the dry seasons, while a mosaic of different land-use types may provide adequate environmental conditions to ant species, maximizing landscape-wide richness throughout the year. © 2010 Entomological Society of America
Lei, Tze‐Huan; Stannard, Stephen R.; Perry, Blake G.; Schlader, Zachary J.; Cotter, James D.
2017-01-01
Key points Despite an attenuated fluctuation in ovarian hormone concentrations in well‐trained women, one in two of such women believe their menstrual cycle negatively impacts training and performance.Forthcoming large international events will expose female athletes to hot environments, and studies evaluating aerobic exercise performance in such environments across the menstrual cycle are sparse, with mixed findings.We have identified that autonomic heat loss responses at rest and during fixed‐intensity exercise in well‐trained women are not affected by menstrual cycle phase, but differ between dry and humid heat.Furthermore, exercise performance is not different across the menstrual cycle, yet is lower in humid heat, in conjunction with reduced evaporative cooling.Menstrual cycle phase does not appear to affect exercise performance in the heat in well‐trained women, but humidity impairs performance, probably due to reduced evaporative power. Abstract We studied thermoregulatory responses of ten well‐trained [V˙O2 max , 57 (7) ml min−1 kg−1] eumenorrheic women exercising in dry and humid heat, across their menstrual cycle. They completed four trials, each of resting and cycling at fixed intensities (125 and 150 W), to assess autonomic regulation, then self‐paced intensity (30 min work trial), to assess behavioural regulation. Trials were in early‐follicular (EF) and mid‐luteal (ML) phases in dry (DRY) and humid (HUM) heat matched for wet bulb globe temperature (WBGT, 27°C). During rest and fixed‐intensity exercise, rectal temperature was ∼0.2°C higher in ML than EF (P < 0.01) independent of environment (P = 0.66). Mean skin temperature did not differ between menstrual phases (P ≥ 0.13) but was higher in DRY than HUM (P < 0.01). Local sweat rate and/or forearm blood flow differed as a function of menstrual phase and environment (interaction: P ≤ 0.01). Exercise performance did not differ between phases [EF: 257 (37), ML: 255 (43) kJ, P = 0.62], but was 7 (9)% higher in DRY than HUM [263 (39), 248 (40) kJ; P < 0.01] in conjunction with equivalent autonomic regulation and thermal strain but higher evaporative cooling [16 (6) W m2; P < 0.01]. In well‐trained women exercising in the heat: (1) menstrual phase did not affect performance, (2) humidity impaired performance due to reduced evaporative cooling despite matched WBGT and (3) behavioural responses nullified thermodynamic and autonomic differences associated with menstrual phase and dry vs. humid heat. PMID:27900769
Lei, Tze-Huan; Stannard, Stephen R; Perry, Blake G; Schlader, Zachary J; Cotter, James D; Mündel, Toby
2017-05-01
Despite an attenuated fluctuation in ovarian hormone concentrations in well-trained women, one in two of such women believe their menstrual cycle negatively impacts training and performance. Forthcoming large international events will expose female athletes to hot environments, and studies evaluating aerobic exercise performance in such environments across the menstrual cycle are sparse, with mixed findings. We have identified that autonomic heat loss responses at rest and during fixed-intensity exercise in well-trained women are not affected by menstrual cycle phase, but differ between dry and humid heat. Furthermore, exercise performance is not different across the menstrual cycle, yet is lower in humid heat, in conjunction with reduced evaporative cooling. Menstrual cycle phase does not appear to affect exercise performance in the heat in well-trained women, but humidity impairs performance, probably due to reduced evaporative power. We studied thermoregulatory responses of ten well-trained [V̇O2 max , 57 (7) ml min -1 kg -1 ] eumenorrheic women exercising in dry and humid heat, across their menstrual cycle. They completed four trials, each of resting and cycling at fixed intensities (125 and 150 W), to assess autonomic regulation, then self-paced intensity (30 min work trial), to assess behavioural regulation. Trials were in early-follicular (EF) and mid-luteal (ML) phases in dry (DRY) and humid (HUM) heat matched for wet bulb globe temperature (WBGT, 27°C). During rest and fixed-intensity exercise, rectal temperature was ∼0.2°C higher in ML than EF (P < 0.01) independent of environment (P = 0.66). Mean skin temperature did not differ between menstrual phases (P ≥ 0.13) but was higher in DRY than HUM (P < 0.01). Local sweat rate and/or forearm blood flow differed as a function of menstrual phase and environment (interaction: P ≤ 0.01). Exercise performance did not differ between phases [EF: 257 (37), ML: 255 (43) kJ, P = 0.62], but was 7 (9)% higher in DRY than HUM [263 (39), 248 (40) kJ; P < 0.01] in conjunction with equivalent autonomic regulation and thermal strain but higher evaporative cooling [16 (6) W m 2 ; P < 0.01]. In well-trained women exercising in the heat: (1) menstrual phase did not affect performance, (2) humidity impaired performance due to reduced evaporative cooling despite matched WBGT and (3) behavioural responses nullified thermodynamic and autonomic differences associated with menstrual phase and dry vs. humid heat. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
NASA Astrophysics Data System (ADS)
Mao, H.; Talbot, R.; Hegarty, J.; Koermer, J.
2011-10-01
Long-term continuous measurements of gaseous elemental mercury (Hgo), reactive gaseous mercury (RGM), and particulate phase mercury (Hgp) were conducted at coastal (Thompson Farm, denoted as TF), marine (Appledore Island, denoted as AI), and elevated inland (Pac Monadnock, denoted as PM) monitoring sites of the AIRMAP Observing Network. Diurnal, seasonal, annual, and interannual variability in Hgo, RGM, and Hgp from the three distinctly different environments were characterized and compared in Part 1. Here in Part 2 relationships between speciated mercury (i.e., Hgo, RGM, and Hgp) and climate variables (e.g., temperature, wind speed, humidity, solar radiation, and precipitation) were examined. The best point-to-point correlations were found between Hgo and temperature in summer at TF and spring at PM, but there was no similar correlation at AI. Subsets of data demonstrated regional impacts of episodic dynamic processes such as strong cyclonic systems on ambient levels of Hgo at all three sites, possibly through enhanced oceanic evasion of Hgo. A tendency of higher levels of RGM and Hgp was identified in spring and summer under sunny conditions in all environments. Specifically, the 10th, 25th, median, 75th, and 90th percentile mixing ratios of RGM and Hgp increased with stronger solar radiation at both the coastal and marine sites. These metrics decreased with increasing wind speed at AI indicating enhanced loss of RGM and Hgp through deposition. RGM and Hgp levels correlated with temperature positively in spring, summer and fall at the coastal and marine locations. In the coastal region relationships between RGM and relative humidity suggested a clear decreasing tendency in all metrics from <40% to 100% relative humidity in all seasons especially in spring, compared to less variability in the marine environment. The effect of precipitation on RGM at coastal and marine locations was similar. At the coastal site, RGM levels were a factor of 3-4 higher under dry conditions than rainy conditions in all seasons. In winter RGM mixing ratios appeared to be mostly above the limit of detection (LOD) during snowfalls suggesting less scavenging efficiency of snow. Mixing ratios of Hgp at the coastal and marine sites remained above the LOD under rainy conditions. Precipitation had negligible impact on the magnitude and pattern of diurnal variation of Hgp in all seasons in the marine environment.
NASA Astrophysics Data System (ADS)
Lemone, Margaret A.; Zipser, Edward J.; Trier, Stanley B.
1998-12-01
A collection of case studies is used to elucidate the influence of environmental soundings on the structure and evolution of the convection in the mesoscale convective systems sampled by the turboprop aircraft in the Tropical Ocean Global Atmosphere (TOGA) Coupled Ocean-Atmosphere Response Experiment (COARE). The soundings were constructed primarily from aircraft data below 5-6 km and primarily from radiosonde data at higher altitudes.The well-documented role of the vertical shear of the horizontal wind in determining the mesoscale structure of tropical convection is confirmed and extended. As noted by earlier investigators, nearly all convective bands occurring in environments with appreciable shear below a low-level wind maximum are oriented nearly normal to the shear beneath the wind maximum and propagate in the direction of the low-level shear at a speed close to the wind maximum; when there is appreciable shear at middle levels (800-400 mb), convective bands form parallel to the shear. With appreciable shear at both levels, the lower-level shear determines the orientation of the primary convective bands. If the midlevel shear is opposite the low-level shear, secondary bands parallel to the midlevel shear will extend rearward from the primary band in later stages of its evolution; if the midlevel shear is 90 degrees to the low-level shear, the primary band will retain its two-dimensional mesoscale structure. Convection has no obvious mesoscale organization on days with little shear or days with widespread convection.Environmental temperatures and humidities have no obvious effect on the mesoscale convective pattern, but they affect COARE convection in other ways. The high tops of COARE convection are related to high parcel equilibrium levels, which approach 100 mb in some cases. Convective available potential energies are larger than those in the GARP (Global Atmospheric Research Program) Atlantic Tropical Experiment (GATE) mainly because of the higher equilibrium levels. The buoyancy integrated over the lowest 500 mb is similar for the two experiments. Convective inihibitions are small, enabling convection to propagate with only weak forcing. Comparison of slow-moving shear-parallel bands in COARE and GATE suggests that lower relative humidities between the top of the mixed layer and 500 mb can shorten their lifetimes significantly.COARE mesoscale organization and evolution differs from what was observed in GATE. Less-organized convection is more common in COARE. Of the convective bands observed, a greater fraction in COARE are faster-moving, shear-perpendicular squall lines. GATE slow-moving lines tend to be longer lived than those for COARE. The differences are probably traceable to differences in environmental shear and relative humidity, respectively.
A modified artificial neural network based prediction technique for tropospheric radio refractivity
Javeed, Shumaila; Javed, Wajahat; Atif, M.; Uddin, Mueen
2018-01-01
Radio refractivity plays a significant role in the development and design of radio systems for attaining the best level of performance. Refractivity in the troposphere is one of the features affecting electromagnetic waves, and hence the communication system interrupts. In this work, a modified artificial neural network (ANN) based model is applied to predict the refractivity. The suggested ANN model comprises three modules: the data preparation module, the feature selection module, and the forecast module. The first module applies pre-processing to make the data compatible for the feature selection module. The second module discards irrelevant and redundant data from the input set. The third module uses ANN for prediction. The ANN model applies a sigmoid activation function and a multi-variate auto regressive model to update the weights during the training process. In this work, the refractivity is predicted and estimated based on ten years (2002–2011) of meteorological data, such as the temperature, pressure, and humidity, obtained from the Pakistan Meteorological Department (PMD), Islamabad. The refractivity is estimated using the method suggested by the International Telecommunication Union (ITU). The refractivity is predicted for the year 2012 using the database of the previous ten years, with the help of ANN. The ANN model is implemented in MATLAB. Next, the estimated and predicted refractivity levels are validated against each other. The predicted and actual values (PMD data) of the atmospheric parameters agree with each other well, and demonstrate the accuracy of the proposed ANN method. It was further found that all parameters have a strong relationship with refractivity, in particular the temperature and humidity. The refractivity values are higher during the rainy season owing to a strong association with the relative humidity. Therefore, it is important to properly cater the signal communication system during hot and humid weather. Based on the results, the proposed ANN method can be used to develop a refractivity database, which is highly important in a radio communication system. PMID:29494609
Ammonia and Carbon Dioxide Concentrations in Disposable and Reusable Ventilated Mouse Cages
Silverman, Jerald; Bays, David W; Cooper, Sheldon F; Baker, Stephen P
2008-01-01
This study compares resuable and disposable individually ventilated mouse cages in terms of the formation of intracage CO2 and NH3. Crl:CD-1(ICR) female mice were placed in either disposable or reusable ventilated cages in a positive pressure animal rack. Intracage CO2 and NH3 were measured once daily for 9 d; temperature and relative humidity were monitored for the first 7 d. Results indicated higher CO2 levels in the rear of the disposable cages and in the front of the reusable cages. This pattern corresponded to where the mice tended to congregate. However, CO2 concentrations did not differ significantly between the 2 cage types. Average CO2 levels in both cage types never exceeded approximately 3000 ppm. Intracage NH3 began to rise in the reusable cages on day 4, reached approximately 50 ppm by day 5 and by day 9 was greater than 150 ppm at the cages' rear sampling port while remaining at approximately 70 ppm at the front sampling port. Intracage NH3 levels in the disposable cages remained less than or equal to 3.2 ppm. Intracage temperature and relative humidity were approximately the same in both cage types. We concluded that the disposable ventilated cage performed satisfactorily under the conditions of the study. PMID:18351723
NASA Astrophysics Data System (ADS)
Hong, Jiaxu; Zhong, Taoling; Li, Huili; Xu, Jianming; Ye, Xiaofang; Mu, Zhe; Lu, Yi; Mashaghi, Alireza; Zhou, Ying; Tan, Mengxi; Li, Qiyuan; Sun, Xinghuai; Liu, Zuguo; Xu, Jianjiang
2016-04-01
Allergic conjunctivitis is a common problem that significantly impairs patients’ quality of life. Whether air pollution serves as a risk factor for the development of allergic conjunctivitis remains elusive. In this paper, we assess the relationship between air pollutants and weather conditions with outpatient visits for allergic conjunctivitis. By using a time-series analysis based on the largest dataset ever assembled to date, we found that the number of outpatient visits for allergic conjunctivitis was significantly correlated with the levels of NO2, O3, and temperature, while its association with humidity was statistically marginal. No associations between PM10, PM2.5, SO2, or wind velocity and outpatient visits were seen. Subgroup analyses showed that sex seemed to modify the effects of humidity on outpatient visits for allergic conjunctivitis, but not for NO2, O3, or temperature. People younger than 40 were found to be susceptible to changes of all four parameters, while those older than 40 were only consistently affected by NO2 levels. Our findings revealed that higher levels of ambient NO2, O3, and temperature increase the chances of outpatient visits for allergic conjunctivitis. Ambient air pollution and weather changes may contribute to the worsening of allergic conjunctivitis.
Hong, Jiaxu; Zhong, Taoling; Li, Huili; Xu, Jianming; Ye, Xiaofang; Mu, Zhe; Lu, Yi; Mashaghi, Alireza; Zhou, Ying; Tan, Mengxi; Li, Qiyuan; Sun, Xinghuai; Liu, Zuguo; Xu, Jianjiang
2016-04-01
Allergic conjunctivitis is a common problem that significantly impairs patients' quality of life. Whether air pollution serves as a risk factor for the development of allergic conjunctivitis remains elusive. In this paper, we assess the relationship between air pollutants and weather conditions with outpatient visits for allergic conjunctivitis. By using a time-series analysis based on the largest dataset ever assembled to date, we found that the number of outpatient visits for allergic conjunctivitis was significantly correlated with the levels of NO2, O3, and temperature, while its association with humidity was statistically marginal. No associations between PM10, PM2.5, SO2, or wind velocity and outpatient visits were seen. Subgroup analyses showed that sex seemed to modify the effects of humidity on outpatient visits for allergic conjunctivitis, but not for NO2, O3, or temperature. People younger than 40 were found to be susceptible to changes of all four parameters, while those older than 40 were only consistently affected by NO2 levels. Our findings revealed that higher levels of ambient NO2, O3, and temperature increase the chances of outpatient visits for allergic conjunctivitis. Ambient air pollution and weather changes may contribute to the worsening of allergic conjunctivitis.
Molecular formula composition of β-caryophyllene ozonolysis SOA formed in humid and dry conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kundu, Shuvashish; Fisseha, Rebeka; Putman, Annie L.
Here, we studied the molecular formula composition of six β-caryophyllene SOA samples using ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry under various reaction conditions. The SOA samples were generated in dry or low relative humidity (RH) chamber conditions with or without cyclohexane. All of the studied SOA mass spectra have three distinct clusters of hundreds of negative ions referred to as Group I (100 < m/z < 400), Group II (400 < m/z < 700) and Group III (700 < m/z < 1 000) compounds. C 14-16H 22-28O 2-11, C 28-29H 42-48O 6-16 and C 42-43H 68-70O 14-16more » were observed as highly abundant organic compounds in the compound class of Group I, II and III, respectively. The relative intensities of most analytes were higher in humid conditions compared to those in dry conditions, indicating the importance of water-dependent reactions and the catalytic role of water both in the presence and absence of cyclohexane. In addition, molecular formulas with higher average carbon numbers were observed in humid SOA than in dry SOA in the absence of cyclohexane, suggesting a decrease of cleavage reactions in humid condition. This study characterizes β-caryophyllene ozonolysis SOA based on ultrahigh mass resolution and demonstrates the significance of humidity in terms of the molecular distributions and relative abundances of the analytes. We also discuss the possible mechanism for the formation of Group I-III compounds based on the current understanding of SOA formation in the atmosphere.« less
Molecular formula composition of β-caryophyllene ozonolysis SOA formed in humid and dry conditions
Kundu, Shuvashish; Fisseha, Rebeka; Putman, Annie L.; ...
2016-12-22
Here, we studied the molecular formula composition of six β-caryophyllene SOA samples using ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry under various reaction conditions. The SOA samples were generated in dry or low relative humidity (RH) chamber conditions with or without cyclohexane. All of the studied SOA mass spectra have three distinct clusters of hundreds of negative ions referred to as Group I (100 < m/z < 400), Group II (400 < m/z < 700) and Group III (700 < m/z < 1 000) compounds. C 14-16H 22-28O 2-11, C 28-29H 42-48O 6-16 and C 42-43H 68-70O 14-16more » were observed as highly abundant organic compounds in the compound class of Group I, II and III, respectively. The relative intensities of most analytes were higher in humid conditions compared to those in dry conditions, indicating the importance of water-dependent reactions and the catalytic role of water both in the presence and absence of cyclohexane. In addition, molecular formulas with higher average carbon numbers were observed in humid SOA than in dry SOA in the absence of cyclohexane, suggesting a decrease of cleavage reactions in humid condition. This study characterizes β-caryophyllene ozonolysis SOA based on ultrahigh mass resolution and demonstrates the significance of humidity in terms of the molecular distributions and relative abundances of the analytes. We also discuss the possible mechanism for the formation of Group I-III compounds based on the current understanding of SOA formation in the atmosphere.« less
Barrientos, Zaidett
2012-09-01
Little is known about how restoration strategies affect aspects like leaf litter's quantity, depth and humidity. I analyzed leaf litter's quantity, depth and humidity yearly patterns in a primary tropical lower montane wet forest and two restored areas: a 15 year old secondary forest (unassisted restoration) and a 40 year old Cupressus lusitanica plantation (natural understory). The three habitats are located in the Rio Macho Forest Reserve, Costa Rica. Twenty litter samples were taken every three months (April 2009-April 2010) in each habitat; humidity was measured in 439g samples (average), depth and quantity were measured in five points inside 50x50cm plots. None of the restoration strategies reproduced the primary forest leaf litter humidity, depth and quantity yearly patterns. Primary forest leaf litter humidity was higher and more stable (mean=73.2), followed by secondary forest (mean=63.3) and cypress plantation (mean=52.9) (Kruskall-Wallis=77.93, n=232, p=0.00). In the primary (Kruskal-Wallis=31.63, n=78, p<0.001) and secondary (Kruskal-Wallis=11.79, n=75, p=0.008) forest litter accumulation was higher during April due to strong winds. In the primary forest (Kruskal-wallis=21.83, n=78, p<0.001) and the cypress plantation (Kruskal-wallis=39.99, n=80, p<0.001) leaf litter depth was shallow in October because heavy rains compacted it. Depth patterns were different from quantity patterns and described the leaf litter's structure in different ecosystems though the year. September 01.
NASA Astrophysics Data System (ADS)
Tornito, A. J. G.
2016-12-01
Understanding the dynamics of climate change is one of the biggest questions that scientists across the globe ask today. With understanding climate change comes the need to understand the ecological systems and how their biological and chemical processes contribute to climate change. As ocean ecosystems, rainforests are very productive systems and are responsible for most of the world's carbon budget. To maintain cooler conditions, tropical forests mitigate warming through evapotranspiration. The purpose of this project was to measure short-term plasticity by looking at stomatal conductance levels of different tropical rainforest species of plants in the rainforest, savannah, and desert habitats in the Biosphere 2 facility in Oracle, Arizona. It is known that stomatal conductance is affected by CO2, H2O, and light availability. It has been observed that temperature levels may not affect stomatal conductance because of the variability associated with it. Results indicated that there is a potential trend amongst these rainforest species when placed in different humidity percentage areas. By understanding stomatal conductance in response to humidity, we can better understand how productive rainforest systems are when humidity levels decrease, which may potentially occur as Earth undergoes global climate change.
Reversible Humidity Sensitive Clothing for Personal Thermoregulation
Zhong, Ying; Zhang, Fenghua; Wang, Meng; Gardner, Calvin J.; Kim, Gunwoo; Liu, Yanju; Leng, Jinsong; Jin, Sungho; Chen, Renkun
2017-01-01
Two kinds of humidity-induced, bendable smart clothing have been designed to reversibly adapt their thermal insulation functionality. The first design mimics the pores in human skin, in which pre-cut flaps open to produce pores in Nafion sheets when humidity increases, as might occur during human sweating thus permitting air flow and reducing both the humidity level and the apparent temperature. Like the smart human sweating pores, the flaps can close automatically after the perspiration to keep the wearer warm. The second design involves thickness adjustable clothes by inserting the bent polymer sheets between two fabrics. As the humidity increases, the sheets become thinner, thus reducing the gap between the two fabrics to reduce the thermal insulation. The insulation layer can recover its original thickness upon humidity reduction to restore its warmth-preservation function. Such humidity sensitive smart polymer materials can be utilized to adjust personal comfort, and be effective in reducing energy consumption for building heating or cooling with numerous smart design. PMID:28281646
Reversible Humidity Sensitive Clothing for Personal Thermoregulation
NASA Astrophysics Data System (ADS)
Zhong, Ying; Zhang, Fenghua; Wang, Meng; Gardner, Calvin J.; Kim, Gunwoo; Liu, Yanju; Leng, Jinsong; Jin, Sungho; Chen, Renkun
2017-03-01
Two kinds of humidity-induced, bendable smart clothing have been designed to reversibly adapt their thermal insulation functionality. The first design mimics the pores in human skin, in which pre-cut flaps open to produce pores in Nafion sheets when humidity increases, as might occur during human sweating thus permitting air flow and reducing both the humidity level and the apparent temperature. Like the smart human sweating pores, the flaps can close automatically after the perspiration to keep the wearer warm. The second design involves thickness adjustable clothes by inserting the bent polymer sheets between two fabrics. As the humidity increases, the sheets become thinner, thus reducing the gap between the two fabrics to reduce the thermal insulation. The insulation layer can recover its original thickness upon humidity reduction to restore its warmth-preservation function. Such humidity sensitive smart polymer materials can be utilized to adjust personal comfort, and be effective in reducing energy consumption for building heating or cooling with numerous smart design.
Reversible Humidity Sensitive Clothing for Personal Thermoregulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Ying; Zhang, Fenghua; Wang, Meng
Two kinds of humidity-induced, bendable smart clothing have been designed to reversibly adapt their thermal insulation functionality. The first design mimics the pores in human skin, in which pre-cut flaps open to produce pores in Nafion sheets when humidity increases, as might occur during human sweating thus permitting air flow and reducing both the humidity level and the apparent temperature. Like the smart human sweating pores, the flaps can close automatically after the perspiration to keep the wearer warm. The second design involves thickness adjustable clothes by inserting the bent polymer sheets between two fabrics. As the humidity increases, themore » sheets become thinner, thus reducing the gap between the two fabrics to reduce the thermal insulation. The insulation layer can recover its original thickness upon humidity reduction to restore its warmth-preservation function. Such humidity sensitive smart polymer materials can be utilized to adjust personal comfort, and be effective in reducing energy consumption for building heating or cooling with numerous smart design.« less
Reversible Humidity Sensitive Clothing for Personal Thermoregulation
Zhong, Ying; Zhang, Fenghua; Wang, Meng; ...
2017-03-10
Two kinds of humidity-induced, bendable smart clothing have been designed to reversibly adapt their thermal insulation functionality. The first design mimics the pores in human skin, in which pre-cut flaps open to produce pores in Nafion sheets when humidity increases, as might occur during human sweating thus permitting air flow and reducing both the humidity level and the apparent temperature. Like the smart human sweating pores, the flaps can close automatically after the perspiration to keep the wearer warm. The second design involves thickness adjustable clothes by inserting the bent polymer sheets between two fabrics. As the humidity increases, themore » sheets become thinner, thus reducing the gap between the two fabrics to reduce the thermal insulation. The insulation layer can recover its original thickness upon humidity reduction to restore its warmth-preservation function. Such humidity sensitive smart polymer materials can be utilized to adjust personal comfort, and be effective in reducing energy consumption for building heating or cooling with numerous smart design.« less
Apparatus and methods for humidity control
NASA Technical Reports Server (NTRS)
Dinauer, William R. (Inventor); Otis, David R. (Inventor); El-Wakil, Mohamed M. (Inventor); Vignali, John C. (Inventor); Macaulay, Philip D. (Inventor)
1994-01-01
Apparatus is provided which controls humidity in a gas. The apparatus employs a porous interface that is preferably a manifolded array of stainless steel tubes through whose porous surface water vapor can pass. One side of the porous interface is in contact with water and the opposing side is in contact with gas whose humidity is being controlled. Water vapor is emitted from the porous surface of the tubing into the gas when the gas is being humidified, and water vapor is removed from the gas through the porous surfaces when the gas is being dehumidified. The temperature of the porous interface relative to the gas temperature determines whether humidification or dehumidification is being carried out. The humidity in the gas is sensed and compared to the set point humidity. The water temperature, and consequently the porous interface temperature, are automatically controlled in response to changes in the gas humidity level above or below the set point. Any deviation from the set point humidity is thus corrected.
Modeling studies of gas movement and moisture migration at Yucca Mountain, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsang, Y.W.; Pruess, K.
1991-06-01
Modeling studies on moisture redistribution processes that are mediated by gas phase flow and diffusion have been carried out. The problem addressed is the effect of a lowered humidity of the soil gas at the land surface on moisture removal from Yucca Mountain, the potential site for a high-level nuclear waste repository. At the land surface, humid formation gas contacts much drier atmospheric air. Near this contact, the humidity of the soil gas may be considerably lower than at greater depth, where the authors expect equilibrium with the liquid phase and close to 100% humidity. The lower relative humidity ofmore » the soil gas may be modeled by imposing, at the land surface, an additional negative capillary suction corresponding to vapor pressure lowering according to Kelvin`s Equation, thus providing a driving force for the upward movement of moisture in both the vapor and liquid phases. Sensitivity studies show that moisture removal from Yucca Mountain arising from the lowered-relative-humidity boundary condition is controlled by vapor diffusion. There is much experimental evidence in the soil literature that diffusion of vapor is enhanced due to pore-level phase change effects by a few orders of magnitude. Modeling results presented here will account for this enhancement in vapor diffusion.« less
NASA Astrophysics Data System (ADS)
Höppe, P.; Martinac, Ivo
In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ''sick building syndrome''.
Höppe, P; Martinac, I
1998-08-01
In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of "sick building syndrome".
A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition
Fong, Ee-May; Chung, Wan-Young
2015-01-01
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3–15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio. PMID:26251913
Analysis of temperature difference on the total of energy expenditure during static bicycle exercise
NASA Astrophysics Data System (ADS)
Sugiono
2016-04-01
How to manage energy expenditure for cyclist is very crucial part to achieve a good performance. As the tropical situation, the differences of temperature level might be contributed in energy expenditure and durability. The aim of the paper is to estimate and to analysis the configuration of energy expenditure for static cycling activity based on heart rate value in room with air conditioning (AC)/no AC treatment. The research is started with study literatures of climate factors, temperature impact on human body, and definition of energy expenditure. The next step is design the experiment for 5 participants in 2 difference models for 26.80C - 74% relative humidity (room no AC) and 23,80C - 54.8% relative humidity (room with AC). The participants’ heart rate and blood pressure are measured in rest condition and in cycling condition to know the impact of difference temperature in energy expenditure profile. According to the experiment results, the reducing of the temperature has significantly impact on the decreasing of energy expenditure at average 0.3 Kcal/minute for all 5 performers. Finally, the research shows that climate condition (temperature and relative humidity) are very important factors to manage and to reach a higher performance of cycling sport.
A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.
Fong, Ee-May; Chung, Wan-Young
2015-08-05
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.
Role of entrainment in convectively-coupled equatorial waves in an aquaplanet model
NASA Astrophysics Data System (ADS)
Peatman, Simon; Methven, John; Woolnough, Steve
2016-04-01
Equatorially-trapped waves are known to be one of the key phenomena in determining the distribution of convective precipitation in the tropics as well as being crucial to the dynamics of the Madden-Julian Oscillation. However, numerical weather prediction models struggle to sustain such waves for a realistic length of time, which has a significant impact on forecasting precipitation for regions such as equatorial Africa. It has been found in the past that enhancing the rate of moisture entrainment can improve certain aspects of parametrized tropical convection in climate models. A parameter F controls the rate of entrainment into the convective plume for deep- and mid-level convection, with F = 1 denoting the control case. Here it is found in an aquaplanet simulation that F > 1 produces more convective precipitation at all zonal wavenumbers. Furthermore, Kelvin wave activity increases for waves with low frequency and zonal wavenumber but is slightly suppressed for shorter, higher-frequency waves, and vice versa for westward-propagating waves. A change in entrainment rate also brings about a change in the basic state wind and humidity fields. Therefore, the question arises as to whether changes in wave activity are due directly to changes in the coupling to the humidity in the waves by entrainment or due to changes in the basic state. An experiment was devised in which the convective parametrization scheme is allowed to entrain a weighted sum of the environmental humidity and a prescribed zonally-symmetric climatology, with a parameter α controlling the extent of the decoupling from the environment. Experiments with this new mechanism in the parametrization scheme reveal a complex relationship. For long waves at low frequency (period > ˜13 days), removing zonal asymmetry in the humidity seen by the entrainment scheme has very little influence on the ratio of eastward- to westward-propagating power. At higher frequencies and zonal wavenumbers, removing this zonal asymmetry acts to suppress wave activity. Enhanced entrainment rate relative to the control case is also shown to slow the phase speed of Kelvin waves by around 20%. The phase speed depends also on the decoupling parameter α, with the minimum speed occurring around the special case α = 1 - 1/F , when the basic state humidity is entrained at the enhanced rate and perturbations from it are entrained at the control rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Qinggang; Kusoglu, Ahmet; Lucas, Ivan T.
2011-08-01
The objective of this effort was to correlate the local surface ionic conductance of a Nafion? 212 proton-exchange membrane with its bulk and interfacial transport properties as a function of water content. Both macroscopic and microscopic proton conductivities were investigated at different relative humidity levels, using electrochemical impedance spectroscopy and current-sensing atomic force microscopy (CSAFM). We were able to identify small ion-conducting domains that grew with humidity at the surface of the membrane. Numerical analysis of the surface ionic conductance images recorded at various relative humidity levels helped determine the fractional area of ion-conducting active sites. A simple square-root relationshipmore » between the fractional conducting area and observed interfacial mass-transport resistance was established. Furthermore, the relationship between the bulk ionic conductivity and surface ionic conductance pattern of the Nafion? membrane was examined.« less
The Environment and the Microbial Ecology of Human Skin
McBride, Mollie E.; Duncan, W. Christopher; Knox, J. M.
1977-01-01
Microbial flora of the skin of three human population groups representing different natural environments was examined quantitatively and qualitatively to determine whether environmental differences in temperature and humidity can influence the microbial flora of normal skin. Five anatomical skin sites - hands, back, axillae, groin, and feet - were sampled from 10 subjects working in a high-humidity, high-temperature environment, 10 subjects from a low-temperature, high-humidity environment, and 10 subjects working in a moderate-temperature and low-humidity environment. Bacterial populations were significantly larger from the back, axillae, and feet in individuals from the high-temperature and high-humidity environment as compared to the moderate-temperature, low-humidity environment. High humidity and low temperature had no significant effect on total populations, but this group showed a higher frequency of isolation of fungi, and gram-negative bacteria from the back and feet. Although there was an indication that increase in the environmental humidity could result in an increased frequency of isolation of gram-negative bacteria, there was no evidence that an increase in either temperature or humidity altered the relative proportions of gram-negative bacteria in the predominantly gram-positive microbial flora found on normal skin. It was concluded that, although climatic changes may cause fluctation in microbial populations from certain sites, they are not a major influence on the ecology of the microbial flora of normal skin in the natural environment. The variables introduced by studying individuals in their natural environment and the influence of these on the results are discussed. PMID:16345214
Angelon-Gaetz, K.A.; Richardson, D.B.; Lipton, D.M.; Marshall, S.W.; Lamb, B.; LoFrese, T.
2014-01-01
Both high and low indoor relative humidity (RH) directly impact indoor air quality (IAQ), an important school health concern. Prior school studies reported a high prevalence of mold, roaches, and water damage; however, few examined associations between modifiable classroom factors and RH, a quantitative indicator of dampness. We recorded RH longitudinally in 134 North Carolina classrooms (n= 9066 classroom-days) to quantify the relationships between modifiable classroom factors and average daily RH below, within, or above levels recommended to improve school IAQ (30–50% or 30–60% RH). The odds of having high RH (>60%) were 5.8 (95% Confidence Interval (CI): 2.9, 11.3) times higher in classrooms with annual compared to quarterly heating, ventilating, and air conditioning (HVAC) system maintenance, and 2.5 (95% CI: 1.5, 4.2) times higher in classrooms with HVAC economizers compared to those without economizers. Classrooms with direct expansion split systems compared to chilled water systems had 2.7 (95% CI: 1.7, 4.4) times higher odds of low RH (<30%). When unoccupied, classrooms with thermostat setbacks had 3.7 (95% CI: 1.7, 8.3) times the odds of high RH (>60%) of those without setbacks. This research suggests actionable decision points for school design and maintenance to prevent high or low classroom RH. PMID:25515546
Humidity compensation of bad-smell sensing system using a detector tube and a built-in camera
NASA Astrophysics Data System (ADS)
Hirano, Hiroyuki; Nakamoto, Takamichi
2011-09-01
We developed a low-cost sensing system robust against humidity change for detecting and estimating concentration of bad smell, such as hydrogen sulfide and ammonia. In the previous study, we developed automated measurement system for a gas detector tube using a built-in camera instead of the conventional manual inspection of the gas detector tube. Concentration detectable by the developed system ranges from a few tens of ppb to a few tens of ppm. However, we previously found that the estimated concentration depends not only on actual concentration, but on humidity. Here, we established the method to correct the influence of humidity by creating regression function with its inputs of discoloration rate and humidity. We studied 2 methods (Backpropagation, Radial basis function network) to get regression function and evaluated them. Consequently, the system successfully estimated the concentration on a practical level even when humidity changes.
de Oliveira, Sergius A. R.; Lucio, Lorena M. C.; Modolo, Norma S. P.; Hayashi, Yoko; Braz, Mariana G.; de Carvalho, Lídia R.; Braz, Leandro G.; Braz, José Reinaldo C.
2017-01-01
Background During anesthesia, as compared with intensive care, the time of the tracheal intubation is much shorter. An inhaled gas minimum humidity of 20 mgH2O.L-1 is recommended to reduce the deleterious effects of dry gas on the airways during anesthesia with tracheal intubation. The Fabius GS Premium® anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat gases in the breathing circuit. A heat and moisture exchanger (HME) is used to further heat and humidify the inhaled gas. The humidity of the gases in the breathing circuit is influenced by the ambient temperature. We compared the humidity of the inhaled gases from a low-flow Fabius anesthesia workstation with or without thermal insulation (TI) of the breathing circuit and with or without an HME. Methods We conducted a prospective randomized trial in 41 adult female patients who underwent elective abdominal surgery. The patients were allocated into four groups according to the devices used to ventilate their lungs using a Dräger Fabius anesthesia workstation with a low gas flow (1 L.min-1): control, with TI, with an HME or with TI and an HME (TIHME). The mean temperature and humidity of the inhaled gases were measured during 2-h after connecting the patients to the breathing circuit. Results The mean inhaled gas temperature and absolute humidity were higher in the HME (29.2±1.3°C; 28.1±2.3 mgH2O·L-1) and TIHME (30.1±1.2°C; 29.4±2.0 mgH2O·L-1) groups compared with the control (27.5±1.0°C; 25.0±1.8 mgH2O·L-1) and TI (27.2±1.1°C; 24.9±1.8 mgH2O·L-1) groups (P = 0.003 and P<0.001, respectively). Conclusions The low-flow Fabius GS Premium breathing circuit provides the minimum humidity level of inhaled gases to avoid damage to the tracheobronchial epithelia during anesthesia. TI of the breathing circuit does not increase the humidity of the inhaled gases, whereas inserting an HME increases the moisture of the inhaled gases closer to physiological values. PMID:28129353
Hwang, Sung Ho; Park, Dong Jin; Park, Wha Me; Park, Dong Uk; Ahn, Jae Kyoung; Yoon, Chung Sik
2016-02-01
This study evaluated the variation over a year in airborne endotoxin levels in the indoor environment of five university laboratories in Seoul, South Korea, and examined the micro-environmental factors that influenced endotoxin levels. These included temperature, relative humidity, CO2, CO, illumination, and wind velocity. A total of 174 air samples were collected and analyzed using the kinetic limulus amebocyte lysate assay. Endotoxin levels ranged from <0.001 to 8.90EU/m(3), with an overall geometric mean of 0.240EU/m(3). Endotoxin levels showed significantly negative correlation with temperature (r=-0.529, p<0.001), CO2 (r=-0.213, p<0.001) and illumination (r=-0.538, p<0.001). Endotoxin levels tended to be higher in winter. Endotoxin levels in laboratories with rabbits were significantly higher than those of laboratories with mice. Multivariate regression analysis showed that the environmental factors affecting endotoxin levels were temperature (coefficient=-0.388, p<0.001) and illumination (coefficient=-0.370, p<0.001). Strategies aimed at reducing airborne endotoxin levels in the indoor environments may be most effective if they focus on illumination. Copyright © 2015 Elsevier Inc. All rights reserved.
Improving the Traceability of Meteorological Measurements at Automatic Weather Stations in Thailand
NASA Astrophysics Data System (ADS)
Keawprasert, T.; Sinhaneti, T.; Phuuntharo, P.; Phanakulwijit, S.; Nimsamer, A.
2017-08-01
A joint project between the National Institute of Metrology Thailand (NIMT) and the Thai Meteorology Department (TMD) was established for improving the traceability of meteorology measurements at automatic weather stations (AWSs) in Thailand. The project aimed to improve traceability of air temperature, relative humidity and atmospheric pressure by implementing on-site calibration facilities and developing of new calibration procedures. First, new portable calibration facilities for air temperature, humidity and pressure were set up as working standard of the TMD. A portable humidity calibrator was applied as a uniform and stable source for calibration of thermo-hygrometers. A dew-point hygrometer was employed as reference hygrometer and a platinum resistance thermometer (PRT) traceable to NIMT was used as reference thermometer. The uniformity and stability in both temperature and relative humidity were characterized at NIMT. A transportable pressure calibrator was used for calibration of air pressure sensor. The estimate overall uncertainty of the calibration setup is 0.2 K for air temperature, 1.0 % for relative humidity and 0.2 hPa for atmospheric pressure, respectively. Second, on-site calibration procedures were developed and four AWSs in the central part and the northern of Thailand were chosen as pilot stations for on-site calibration using the new calibration setups and developed calibration procedures. At each station, the calibration was done at the minimum temperature, average temperature and maximum temperature of the year, for air temperature, 20 %, 55 % and 90 % for relative humidity at the average air temperature of that station and at a one-year statistics pressure range for atmospheric pressure at ambient temperature. Additional in-field uncertainty contributions such as the temperature dependence on relative humidity measurement were evaluated and included in the overall uncertainty budget. Preliminary calibration results showed that using a separate PRT probe at these AWSs would be recommended for improving the accuracy of air temperature measurement. In case of relative humidity measurement, the data logger software is needed to be upgraded for achieving higher accuracy of less than 3 %. For atmospheric pressure measurement, a higher accuracy barometer traceable to NIMT could be used to reduce the calibration uncertainty to below 0.2 hPa.
Effect of feed-gas humidity on nitrogen atmospheric-pressure plasma jet for biological applications.
Stephan, Karl D; McLean, Robert J C; DeLeon, Gian; Melnikov, Vadim
2016-11-14
We investigate the effect of feed-gas humidity on the oxidative properties of an atmospheric-pressure plasma jet using nitrogen gas. Plasma jets operating at atmospheric pressure are finding uses in medical and biological settings for sterilization and other applications involving oxidative stress applied to organisms. Most jets use noble gases, but some researchers use less expensive nitrogen gas. The feed-gas water content (humidity) has been found to influence the performance of noble-gas plasma jets, but has not yet been systematically investigated for jets using nitrogen gas. Low-humidity and high-humidity feed gases were used in a nitrogen plasma jet, and the oxidation effect of the jet was measured quantitatively using a chemical dosimeter known as FBX (ferrous sulfate-benzoic acid-xylenol orange). The plasma jet using high humidity was found to have about ten times the oxidation effect of the low-humidity jet, as measured by comparison with the addition of measured amounts of hydrogen peroxide to the FBX dosimeter. Atmospheric-pressure plasma jets using nitrogen as a feed gas have a greater oxidizing effect with a high level of humidity added to the feed gas.
Gravimetric humidity sensor based on ZnO nanorods covered piezoresistive Si microcantilever
NASA Astrophysics Data System (ADS)
Xu, Jiushuai; Bertke, Maik; Li, Xiaojing; Gad, Alaaeldin; Zhou, Hao; Wasisto, Hutomo Suryo; Peiner, Erwin
2017-06-01
A ZnO nanorods film covered silicon resonant cantilever sensor is developed for atmosphere humidity detection by monitoring the resonant frequency shifts induced by the additional weight of adsorbed water molecules. Two different crystalline seed-layer deposition methods were applied to grow different nanorods films. The morphology of the ZnO films were characterized and the sensor sensitivities were measured under different relative humidity (RH) levels. The experiments results showed that this novel humidity sensor with ZnO nanorods has a sensitivity of 101.5 +/- 12.0 ppm/RH% (amount of adsorbed water of 36.9 +/- 4.4 ng/RH%), indicating its potential for portable sensing applications.
Sutherland, Michael F.; Johnston, Fay H.; Lampugnani, Edwin R.; McCarthy, Michael A.; Jacobs, Stephanie J.; Pezza, Alexandre B.; Newbigin, Edward J.
2018-01-01
We examine the seasonality of asthma-related hospital admissions in Melbourne, Australia, in particular the contribution and predictability of episodic thunderstorm asthma. Using a time-series ecological approach based on asthma admissions to Melbourne metropolitan hospitals, we identified seasonal peaks in asthma admissions that were centred in late February, June and mid-November. These peaks were most likely due to the return to school, winter viral infections and seasonal allergies, respectively. We performed non-linear statistical regression to predict daily admission rates as functions of the seasonal cycle, weather conditions, reported thunderstorms, pollen counts and air quality. Important predictor variables were the seasonal cycle and mean relative humidity in the preceding two weeks, with higher humidity associated with higher asthma admissions. Although various attempts were made to model asthma admissions, none of the models explained substantially more variation above that associated with the annual cycle. We also identified a list of high asthma admissions days (HAADs). Most HAADs fell in the late-February return-to-school peak and the November allergy peak, with the latter containing the greatest number of daily admissions. Many HAADs in the spring allergy peak may represent episodes of thunderstorm asthma, as they were associated with rainfall, thunderstorms, high ambient grass pollen levels and high humidity, a finding that suggests thunderstorm asthma is a recurrent phenomenon in Melbourne that occurs roughly once per five years. The rarity of thunderstorm asthma events makes prediction challenging, underscoring the importance of maintaining high standards of asthma management, both for patients and health professionals, especially during late spring and early summer. PMID:29649224
Effect of salt on the glass transition of condensed tapioca starch systems.
Chuang, Lillian; Panyoyai, Naksit; Shanks, Robert A; Kasapis, Stefan
2017-08-15
This work examines the effect of including hydrated NaCl and CaCl 2 (up to 6% w/w) on the physicochemical properties of condensed tapioca starch. Samples were prepared by hot pressing at 120°C to produce condensed systems that covered a range of moisture contents from 7.34% w/w (23% relative humidity) to 19.52% w/w (75% relative humidity). Tensile storage modulus and heat flow measurements were taken using DMA and MDSC, which were accompanied by FTIR, WAXD and ESEM. Increasing the salt level enhances the mechanical strength of starch in the glassy state and shifts the glass transition temperature to a higher value. Antiplasticising effects of NaCl and CaCl 2 on the non-phosphorylated tapioca starch are indistinguishable from each other. Observations are complemented by intensification of absorbance peaks in FTIR spectra and a systematic change in shape and intensity of diffraction patterns with increasing addition of salt consistent with interactions between added ions and macromolecule. Copyright © 2017. Published by Elsevier Ltd.
2012-01-01
Background Ariadne’s house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Results Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. Conclusions The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments. PMID:23190798
Liao, Yupeng; Hu, Rui; Wang, Zhisheng; Peng, Quanhui; Dong, Xianwen; Zhang, Xiangfei; Zou, Huawei; Pu, Qijian; Xue, Bai; Wang, Lizhi
2018-06-25
This study was to determine differences in the global metabolic profiles of serum and urine of Xuanhan yellow cattle, Simmental crossbred cattle (Simmental × Xuanhan yellow cattle), and cattle-yaks (Jersey × Maiwa yak) under heat stress (temperature-humidity index remained above 80 for 1 week). A total of 55 different metabolites associated with the three breeds were identified in the serum and urine samples by gas chromatography-mass spectrometry. The metabolic adaptations to heat stress are heterogeneous. Cattle-yaks mobilize a greater amount of body protein to release glucogenic amino acids to supply energy, whereas the tricarboxylic acid cycle is inhibited. Simmental crossbred cattle mobilize a greater amount of body fat to use free fatty acids as an energy source. In comparison with Simmental crossbred cattle and cattle-yaks, Xuanhan yellow cattle have higher glycolytic activity and possess a stronger antioxidant defense system and are, in conclusion, more adapted to hot and humid environments.
Bruce, Caroline D; Fegely, Kurt A; Rajabi-Siahboomi, Ali R; McGinity, James W
2010-05-01
The objective of this study was to investigate the influence of talc and humidity conditions during storage on the crystal growth of guaifenesin on the surface of melt-extruded matrix tablets. Tablets consisted of the model drug guaifenesin in a matrix of either Acryl-EZE(R) or Eudragit(R) L10055 and either no talc, 25% or 50% talc. After processing, the hot-melt-extruded matrix tablets were supersaturated with amorphous guaifenesin, which resulted in the development of guaifenesin drug crystals on exposed surfaces of the tablet during storage (all tablets were stored at 24 degrees C). A previously developed, quantitative test was used to assay for surface guaifenesin. In tablets with a drug-to-polymer ratio of 19:81, talc-containing tablets exhibited an earlier onset of crystal growth (storage at 17% relative humidity). The presence of talc also increased the amount of surface crystallization and was independent of the talc concentration, since the talc levels used in this study exceeded the critical nucleant concentration. Additional non-melting components did not have an additive effect on surface crystal growth. High humidity during storage (78%) increased guaifenesin crystallization, but moisture uptake of tablets did not correlate with increased drug recrystallization. When storage at 17% relative humidity was interrupted for 3days by storage at 78% relative humidity before the tablets were returned to their previous low RH storage conditions, crystal growth quickly increased during the high RH interval and remained at an elevated level throughout the remaining storage period. A similar intermediate period of low, 17% relative humidity in tablets stored before and after that time at 78% RH did not affect surface crystallization levels. The effects of humidity and talc on the crystallization of guaifenesin from melt-extruded dosage forms supersaturated with amorphous drug were ascribed to heterogeneous nucleation.
NASA Astrophysics Data System (ADS)
Pla, Concepcion; Galiana-Merino, Juan Jose; Cuezva, Soledad; Fernandez-Cortes, Angel; Garcia-Anton, Elena; Cuevas, Jaime; Cañaveras, Juan Carlos; Sanchez-Moral, Sergio; Benavente, David
2014-05-01
Shallow vadose environments below soil, mainly caves, show significant seasonal and even daily variations in gas composition of ground air, which involves the exchange of large amounts of gases, e.g. greenhouse gases (GHGs) as CO2 or CH4, with the lower troposphere. To understand better the role of caves as a sink or depot of GHGs, geochemical tracing of air (atmosphere, soil and ground air) was performed at Rull cave (southeast Spain) by monitoring CH4, CO2 and the stable carbon isotopic delta13C[CO2] using cavity ring-down spectroscopy (CRDS). A comprehensive microclimatic monitoring of exterior and cave atmosphere was simultaneously conducted to GHGs-tracking, including factors as temperature, barometric pressure, relative humidity and concentration of CO2 and 222Rn. The analysis of the measured data allows understanding outgassing and isolation processes taking place in the karst cavity. Annual patterns of gases behaviour can be distinguished, depending on the prevailing relationship between outer atmosphere, indoor atmosphere and soil system. Cave air temperature fluctuates around 15.7 ºC and relative humidity remains higher than 96% the whole annual cycle. The mean concentration of 222Rn is 1584 Bq m-3 while CO2 remains 1921 ppm. When external temperature is higher of indoor temperature (April-October), the highest levels of both trace gases are reached, while levels drop to its lowest values in the coldest months. Preliminary results obtained show an annual variation in concentration of CO2 inside the cave between 3300 ppm and 900 ppm, whereas corresponding isotopic signal delta13CO2 varies between -24‰ and -21‰. The results have been studied by Keeling model that approximates the isotopic signal of the source contribution in a resulting air mix. The values registered inside the cave were represented joined to results for exterior air (average values round 410 ppm of CO2 and -9 ‰ for delta13C). Value obtained is -27‰ pointing to a high influence of the soil produced CO2 (with a characteristic signal of -27‰ for C3 plants) in the cave atmosphere. The lowest levels of CO2 coincide with the highest of delta13C pointing to an input of exterior air during the degassing stage. Regarding the CH4 concentration inside the cave, higher values (0.3 ppm average concentration) are observed during outgassing stage than the isolation period (CH4 mean value of 0 ppm), confirming a major connection with the exterior atmosphere (average value of methane 1.8 ppm) during outgassing stage. By introducing wavelet analysis on obtained time series filtered signal of raw data show strong dependencies between trace gases and studied parameters. For instance, values of coherence between relative humidity and CO2 or 222Rn concentration are higher than 0.9. Results show that gas patterns dependence on relative humidity, atmospheric pressure and temperatures (indoor and outdoor) prevails throughout a year, determining the outgassing and isolation periods identified by statistical analyses. The measured of delta13C and CH4 concentration became a useful tool to understand processes affecting cave air and driving parameters variations inside the cave. Moreover, combining wavelet analysis, statistics and resemblance techniques, seasonal and transient behaviour of gases exchange can be highlighted in subterranean sites as Rull Cave.
Testa, Francesco; Marano, Giuseppe; Ambrogi, Federico; Boracchi, Patrizia; Casula, Antonio; Biganzoli, Elia; Moroni, Paolo
2017-10-01
Elevated bulk tank milk somatic cell count (BMSCC) has a negative impact on milk production, milk quality, and animal health. Seasonal increases in herd level somatic cell count (SCC) are commonly associated with elevated environmental temperature and humidity. The Temperature Humidity Index (THI) has been developed to measure general environmental stress in dairy cattle; however, additional work is needed to determine a specific effect of the heat stress index on herd-level SCC. Generalized Additive Model methods were used for a flexible exploration of the relationships between daily temperature, relative humidity, and bulk milk somatic cell count. The data consist of BMSCC and meteorological recordings collected between March 2009 and October 2011 of 10 dairy farms. The results indicate that, an average increase of 0.16% of BMSCC is expected for an increase of 1°C degree of temperature. A complex relationship was found for relative humidity. For example, increase of 0.099%, 0.037% and 0.020% are expected in correspondence to an increase of relative humidity from 50% to 51%, 80% to 81%; and 90% to 91%, respectively. Using this model, it will be possible to provide evidence-based advice to dairy farmers for the use of THI control charts created on the basis of our statistical model. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sugahara, Michio; Nishimura, Yasuichiro; Sakamoto, Fumio
2012-01-01
Upon capture in a bee ball (i.e., a dense cluster of Japanese honeybees forms in response to a predatory attack), an Asian giant hornet causes a rapid increase in temperature, carbon dioxide (CO₂), and humidity. Within five min after capture, the temperature reaches 46°C, and the CO₂ concentration reaches 4%. Relative humidity gradually rises to 90% or above in 3 to 4 min. The hornet dies within 10 min of its capture in the bee ball. To investigate the effect of temperature, CO₂, and humidity on hornet mortality, we determined the lethal temperature of hornets exposed for 10 min to different humidity and CO₂/O₂ (oxygen) levels. In expiratory air (3.7% CO₂), the lethal temperature was ≥ 2° lower than that in normal air. The four hornet species used in this experiment died at 44-46°C under these conditions. Hornet death at low temperatures results from an increase in CO₂ level in bee balls. Japanese honeybees generate heat by intense respiration, as an overwintering strategy, which produces a high CO₂ and humidity environment and maintains a tighter bee ball. European honeybees are usually killed in the habitat of hornets. In contrast, Japanese honeybees kill hornets without sacrificing themselves by using heat and respiration by-products and forming tight bee balls.
Spatially resolved resistance of NiO nanostructures under humid environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Christopher B; Ievlev, Anton; Collins, Liam F
2016-01-01
The spatially resolved electrical response of polycrystalline NiO films composed of 40 nm crystallites was investigated under different relative humidity levels (RH). The topological and electrical properties (surface potential and resistance) were characterized with sub 25nm resolution using Kelvin probe force microscopy (KPFM) and conductive scanning probe microscopy under argon atmosphere at 0%, 50%, and 80% relative humidity. The dimensionality of surface features obtained through autocorrelation analysis of topological maps increased linearly with increased relative humidity, as water was adsorbed onto the film surface. Surface potential decreased from about 280mV to about 100 mV and resistance decreased from about 5more » G to about 3 G , in a nonlinear fashion when relative humidity was increased from 0% to 80%. Spatially resolved surface potential and resistance of the NiO films was found to be heterogeneous throughout the film, with distinct domains that grew in size from about 60 nm to 175 nm at 0% and 80% RH levels, respectively. The heterogeneous character of the topological, surface potential, and resistance properties of the polycrystalline NiO film observed under dry conditions decreased with increased relative humidity, yielding nearly homogeneous surface properties at 80% RH, suggesting that the nanoscale potential and resistance properties converge with the mesoscale properties as water is adsorbed onto the NiO film.« less
NASA Technical Reports Server (NTRS)
Vukovich, F. M. (Principal Investigator)
1982-01-01
Infrared and visible HCMM data were used to examine the potential application of these data to define initial and boundary conditions for mesoscale numerical models. Various boundary layer models were used to calculate the distribution of the surface heat flux, specific humidity depression (the difference between the specific humidity in the air at approxmately the 10 m level and the specific humidity at the ground), and the eddy vicosity in a 72 km by 72 km area centered about St. Louis, Missouri. Various aspects of the implications of the results on the meteorology of St. Louis are discussed. Overall, the results indicated that a reasonable estimate of the surface heat flux, urban albedo, ground temperature, and specific humidity depression can be obtained using HCMM satellite data. Values of the ground-specific humidity can be obtained if the distribution of the air-specific humidity is available. More research is required in estimating the absolute magnitude of the specific humidity depression because calculations may be sensitive to model parameters.
Fiberboard humidity data for 9975 shipping packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
2015-07-31
The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis.Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity andmore » temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts.« less
Fiberboard humidity data for 9975 shipping packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis.Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity andmore » temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts.« less
High Humidity Leads to Loss of Infectious Influenza Virus from Simulated Coughs
Noti, John D.; Blachere, Francoise M.; McMillen, Cynthia M.; Lindsley, William G.; Kashon, Michael L.; Slaughter, Denzil R.; Beezhold, Donald H.
2013-01-01
Background The role of relative humidity in the aerosol transmission of influenza was examined in a simulated examination room containing coughing and breathing manikins. Methods Nebulized influenza was coughed into the examination room and Bioaerosol samplers collected size-fractionated aerosols (<1 µM, 1–4 µM, and >4 µM aerodynamic diameters) adjacent to the breathing manikin’s mouth and also at other locations within the room. At constant temperature, the RH was varied from 7–73% and infectivity was assessed by the viral plaque assay. Results Total virus collected for 60 minutes retained 70.6–77.3% infectivity at relative humidity ≤23% but only 14.6–22.2% at relative humidity ≥43%. Analysis of the individual aerosol fractions showed a similar loss in infectivity among the fractions. Time interval analysis showed that most of the loss in infectivity within each aerosol fraction occurred 0–15 minutes after coughing. Thereafter, losses in infectivity continued up to 5 hours after coughing, however, the rate of decline at 45% relative humidity was not statistically different than that at 20% regardless of the aerosol fraction analyzed. Conclusion At low relative humidity, influenza retains maximal infectivity and inactivation of the virus at higher relative humidity occurs rapidly after coughing. Although virus carried on aerosol particles <4 µM have the potential for remaining suspended in air currents longer and traveling further distances than those on larger particles, their rapid inactivation at high humidity tempers this concern. Maintaining indoor relative humidity >40% will significantly reduce the infectivity of aerosolized virus. PMID:23460865
Kundu Chowdhury, Anirban; Debsarkar, Anupam; Chakrabarty, Shibnath
2015-01-01
The objective of the research work is to assess day time traffic noise level at curbside open-air microenvironment of Kolkata city, India under heterogeneous environmental conditions. Prevailing traffic noise level in terms of A-weighted equivalent noise level (Leq) at the microenvironment was in excess of 12.6 ± 2.1 dB(A) from the day time standard of 65 dB(A) for commercial area recommended by the Central Pollution Control Board (CPCB) of India. Noise Climate and Traffic Noise Index of the microenvironment were accounted for 13 ± 1.8 dB(A) and 88.8 ± 6.1 dB(A) respectively. A correlation analysis explored that prevailing traffic noise level of the microenvironment had weak negative (-0.21; p < 0.01) and very weak positive (0.19; p < 0.01) correlation with air temperature and relative humidity. A Varimax rotated principal component analysis explored that motorized traffic volume had moderate positive loading with background noise component (L90, L95, L99) and prevailing traffic noise level had very strong positive loading with peak noise component (L1, L5, L10). Background and peak noise component cumulatively explained 80.98 % of variance in the data set. Traffic noise level at curbside open-air microenvironment of Kolkata City was higher than the standard recommended by CPCB of India. It was highly annoying also. Air temperature and relative humidity had little influence and the peak noise component had the most significant influence on the prevailing traffic noise level at curbside open-air microenvironment. Therefore, traffic noise level at the microenvironment of the city can be reduced with careful honking and driving.
Ari, Arzu; Alwadeai, Khalid S; Fink, James B
2017-05-01
Many in vitro models report higher inhaled dose with dry versus heated humidity. Heat-and-moisture exchangers (HMEs) provide passive humidity in ventilator-dependent patients but act as a barrier to aerosol. The HMEs designed to allow aerosol delivery (HME-ADs) have not been well described. The purpose of this study is to determine the impact on aerosol deposition of HME-ADs with and without active exhaled humidity in a simulated ventilator-dependent adult model. We used an in vitro lung model consisting of an intubated teaching mannequin with an endotracheal tube of 8.0 mm inner diameter with bronchi directly attached to a collecting filter and passive rubber test lung to provide testing without active exhaled humidity. To simulate exhaled humidity, a Cascade humidifier (37°C and 100% relative humidity) was placed between the collecting filter and test lung, simulating body temperature and pressure saturated exhaled humidity at the bronchi. Albuterol sulfate (2.5 mg/3 mL) was administered with a mesh nebulizer (Aerogen Solo) placed in the inspiratory limb of the ventilator circuit at the Y-piece, with no HME in place (control) and with 3 HME-AD devices, including the CircuVent, Humid-Flo, and AirLife, with and without exhaled humidity. Drug was eluted from the collecting filter and analyzed with spectrophotometry. Student t tests and analysis of variance were used for data analysis ( P < .05). The percentage of drug dose delivered (mean ± SD) distal to the bronchi in the control experiments was greater than all of the HME-ADs without exhaled humidity 18 ± 0.7 and with active exhaled humidity 10.8 ± 0.2% ( P < .005). Without exhaled humidity, aerosol delivery with the CircuVent (12.6 ± 0.8), Humid-Flo (15.3 ± 0.8), and AirLife (12.0 ± 0.5) was less than control ( P < .001, P = .01 and P < .001, respectively). In contrast, with exhaled humidity, no difference was found between control and HME-ADs ( P = .89). Also, a greater variation between control and the 3 HME-ADs was observed without exhaled humidity. Drug delivery without exhaled humidity exceeded aerosol deposition obtained with exhaled humidity in all conditions tested in this study. In this model simulating active exhaled humidity, aerosol drug delivery was lower and more consistent with both control and the HME-ADs than with the standard nonhumidified model. Further studies are needed to determine whether greater deposition in a dry model is an artifact of the model that does not simulate exhaled humidity. Copyright © 2017 by Daedalus Enterprises.
Goldhawk, C; Crowe, T; González, L A; Janzen, E; Kastelic, J; Pajor, E; Schwartzkopf-Genswein, K
2014-09-01
Measuring animal-level conditions during transit provides information regarding the true risk of environmental challenges to cattle welfare during transportation. However, due to constraints on placing loggers at the animal level, there is a need to identify appropriate proxy locations. The objective was to evaluate 8 distributions of ceiling-level loggers in the deck and belly compartments of pot-belly trailers for assessing animal-level temperature and humidity during 5 to 18 h commercial transportation of feeder cattle. Ambient conditions during transportation ranged from 3.6 to 45.2°C (20.3 ± 7.61°C, mean ± SD). When considering the entire journey, average differences between ceiling and animal-level temperatures were similar among logger layouts (P > 0.05). The uncertainty in the difference in temperature and humidity between locations was high relative to the magnitude of the difference between animal- and ceiling-level conditions. Single-logger layouts required larger adjustments to predict animal-level conditions within either compartment, during either the entire journey or when the trailer was stationary (P < 0.05). Within certain logger layouts, there were small but significant differences in the ability of regression equations to predict animal-level conditions that were associated with cattle weight and available space relative to body size. Furthermore, evaluation of logger layouts based solely on the entire journey without consideration of stationary periods did not adequately capture variability in layout performance. In conclusion, to adequately monitor animal-level temperature and humidity, 10 loggers distributed throughout the compartment was recommended over single-logger layouts within both the deck and belly compartments of pot-belly trailers transporting feeder cattle in warm weather.
[Influence of relative humidity on the Adoxophyes orana experimental population].
Sun, Li; Sun, Rui-hong; Qiu, Gui-sheng; Yan, Wen-tao; Zhang, Huai-jiang
2014-12-01
In order to explore the effects of relative humidity (RH) on the population growth of summer fruit tortrix moth Adoxophyes orana, the development, survival, fecundity and longevity of A. orana were assessed at 6 different constant humidities (40%, 50%, 60%, 70%, 80% and 90%), (25 +/- 1) degrees C and a photoperiod of 12L:12D in the laboratory. The results showed that immature developmental time was gradually shortened with the increasing humidity at 40%-90% RH, ranged from 30.31 d at 40% RH to 25.87 d at 90% RH. However, the survival rate for immature moth was gradually increased from 40% RH to 90% RH. Hatchability was inhibited significantly by low humidity and the lowest was 39.3% at 40% RH. And at 80% RH, the longevity of adults was the longest, the oviposition was the most (110.8 eggs per female) , and the survival rates for eggs and larvae were the highest. It resulted in the highest net reproductive rate (R0=26.46) and intrinsic rate of increase (r(m) = 0.1018). In conclusion, the development and fecundity of A. orana were promoted and improved at the higher humidity.
Kim, Mi Jung; Baek, Kon; Park, Chung-Mo
2009-08-01
Transient genetic transformation of plant organs is an indispensable way of studying gene function in plants. This study was aimed to develop an optimized system for transient Agrobacterium-mediated transformation of the Arabidopsis leaves. The beta-glucuronidase (GUS) reporter gene was employed to evaluate growth and biochemical parameters that influence the levels of transient expression. The effects of plant culture conditions, Agrobacterial genetic backgrounds, densities of Agrobacterial cell suspensions, and of several detergents were analyzed. We found that optimization of plant culture conditions is the most critical factor among the parameters analyzed. Higher levels of transient expression were observed in plants grown under short day conditions (SDs) than in plants grown under long day conditions (LDs). Furthermore, incubation of the plants under SDs at high relative humidity (85-90%) for 24 h after infiltration greatly improved the levels of transient expression. Under the optimized culture conditions, expression of the reporter gene reached the peak 3 days after infiltration and was rapidly decreased after the peak. Among the five Agrobacterial strains examined, LAB4404 produced the highest levels of expression. We also examined the effects of detergents, including Triton X-100, Tween-20, and Silwet L-77. Supplementation of the infiltration media either with 0.01% Triton X-100 or 0.01% Tween-20 improved the levels of expression by approximately 1.6-fold. Our observations indicate that transient transformation of the Arabidopsis leaves in the infiltration media supplemented with 0.01% Triton X-100 and incubation of the infiltrated plants under SDs at high relative humidity are necessary for maximal levels of expression.
The humidity dependence of ozone deposition onto a variety of building surfaces
NASA Astrophysics Data System (ADS)
Grøntoft, Terje; Henriksen, Jan F.; Seip, Hans M.
Measurements of the dry deposition velocity of O 3 to material samples of calcareous stone, concrete and wood at varying humidity of the air, were performed in a deposition chamber. Equilibrium surface deposition velocities were found for various humidity values by fitting a model to the time-dependent deposition data. A deposition velocity-humidity model was derived giving three separate rate constants for the surface deposition velocities, i.e. on the dry surface, on the first mono-layer of adsorbed water and on additional surface water. The variation in the dry air equilibrium surface deposition velocities among the samples correlated with variations in effective areas, with larger effective areas giving higher measured deposition velocities. A minimum for the equilibrium surface deposition velocity was generally measured at an intermediate humidity close to the humidity found to correspond to one mono-layer of water molecules on the surfaces. At low air humidity the equilibrium surface deposition velocity of O 3 was found to decrease as more adsorbed water prevented direct contact of the O 3 molecules with the surface. This was partly compensated by an increase as more adsorbed water became available for reaction with O 3. At high air humidity the equilibrium surface deposition velocity was found to increase as the mass of water on the surface increased. The deposition velocity on bulk de-ionised water at RH=90% was an order of magnitude lower than on the sample surfaces.
Overview of the International Space Station System Level Trace Contaminant Injection Test
NASA Technical Reports Server (NTRS)
Tatara, James D.; Perry, Jay L.; Franks, Gerald D.
1997-01-01
Trace contaminant control onboard the International Space Station will be accomplished not only by the Trace Contaminant Control Subassembly but also by other Environmental Control and Life Support System subassemblies. These additional removal routes include absorption by humidity condensate in the Temperature and Humidity Control Condensing Heat Exchanger and adsorption by the Carbon Dioxide Removal Assembly. The Trace Contaminant Injection Test, which was performed at NASA's Marshall Space Flight Center, investigated the system-level removal of trace contaminants by the International Space Station Atmosphere Revitalization, and Temperature/Humidity Control Subsystems, (November-December 1997). It is a follow-on to the Integrated Atmosphere Revitalization Test conducted in 1996. An estimate for the magnitude of the assisting role provided by the Carbon Dioxide Removal Assembly and the Temperature and Humidity Control unit was obtained. In addition, data on the purity of Carbon Dioxide Removal Assembly carbon dioxide product were obtained to support Environmental Control and Life Support System Air Revitalization Subsystem loop closure.
Zhao, Chanjuan; Xie, Junqi; Li, Li; Cao, Chongjiang
2017-09-20
The transcriptomes of paddy rice in response to high temperature and humidity were studied using a high-throughput RNA sequencing approach. Effects of high temperature and humidity on the sucrose and starch contents and α/β-amylase activity were also investigated. Results showed that 6876 differentially expressed genes (DEGs) were identified in paddy rice under high temperature and humidity storage. Importantly, 12 DEGs that were downregulated fell into the "starch and sucrose pathway". The quantitative real-time polymerase chain reaction assays indicated that expression of these 12 DEGs was significantly decreased, which was in parallel with the reduced level of enzyme activities and the contents of sucrose and starch in paddy rice stored at high temperature and humidity conditions compared to the control group. Taken together, high temperature and humidity influence the quality of paddy rice at least partially by downregulating the expression of genes encoding sucrose transferases and hydrolases, which might result in the decrease of starch and sucrose contents.
An Investigation of the Wear on Silicon Surface at High Humidity.
Wang, Xiaodong; Guo, Jian; Xu, Lin; Cheng, Guanggui; Qian, Linmao
2018-06-16
Using an atomic force microscope (AFM), the wear of monocrystalline silicon (covered by a native oxide layer) at high humidity was investigated. The experimental results indicated that tribochemistry played an important role in the wear of the silicon at different relative humidity levels (RH = 60%, 90%). Since the tribochemical reactions were facilitated at 60% RH, the wear of silicon was serious and the friction force was around 1.58 μN under the given conditions. However, the tribochemical reactions were restrained when the wear pair was conducted at high humidity. As a result, the wear of silicon was very slight and the friction force decreased to 0.85 μN at 90% RH. The slight wear of silicon at high humidity was characterized by etching tests. It was demonstrated that the silicon sample surface was partly damaged and the native oxide layer on silicon sample surface had not been totally removed during the wear process. These results may help us optimize the tribological design of dynamic microelectromechanical systems working in humid conditions.
NASA Astrophysics Data System (ADS)
Chakrabarti, Bhabesh; Fine, Philip M.; Delfino, Ralph; Sioutas, Constantinos
The need for continuous personal monitoring for exposure to particulate matter has been demonstrated by recent health studies showing effects of PM exposure on time scales of less than a few hours. Filter-based methods cannot measure this short-term variation of PM levels, which can be quite significant considering human activity patterns. The goal of this study was to evaluate the active-flow personal DataRAM for PM 2.5 (MIE pDR-1200; Thermo Electron Corp., Franklin, MA) designed as a wearable monitor to continuously measure particle exposure. The instrument precision was found to be good (2.1%) and significantly higher than the passive pDR configuration tested previously. A comparison to other proven continuous monitors resulted in good agreement at low relative humidities. Results at higher humidity followed predictable trends and provided a correction scheme that improved the accuracy of pDR readings. The pDR response to particle size also corresponded to previously observed and theoretical errors. The active flow feature of the pDR allows collection of the sampled particles on a back-up filter. The 24-h mass measured on this filter was found to compare very well with a Federal Reference Method for PM 2.5 mass.
Ozone reaction with clothing and its initiated VOC emissions in an environmental chamber.
Rai, A C; Guo, B; Lin, C-H; Zhang, J; Pei, J; Chen, Q
2014-02-01
Human health is adversely affected by ozone and the volatile organic compounds (VOCs) produced from its reactions in the indoor environment. Hence, it is important to characterize the ozone-initiated reactive chemistry under indoor conditions and study the influence of different factors on these reactions. This investigation studied the ozone reactions with clothing through a series of experiments conducted in an environmental chamber under various conditions. The study found that the ozone reactions with a soiled (human-worn) T-shirt consumed ozone and generated VOCs. The ozone removal rate and deposition velocity for the T-shirt increased with the increasing soiling level and air change rate, decreased at high ozone concentrations, and were relatively unaffected by the humidity. The deposition velocity for the soiled T-shirt ranged from 0.15 to 0.29 cm/s. The ozone-initiated VOC emissions included C6-C10 straight-chain saturated aldehydes, acetone, and 4-OPA (4-oxopentanal). The VOC emissions were generally higher at higher ozone, humidity, soiling of T-shirt, and air change rate. The total molar yield was approximately 0.5 in most cases, which means that for every two moles of ozone removed by the T-shirt surface, one mole of VOCs was produced. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The Evaporative Function of Cockroach Hygroreceptors
Tichy, Harald; Kallina, Wolfgang
2013-01-01
Insect hygroreceptors associate as antagonistic pairs of a moist cell and a dry cell together with a cold cell in small cuticular sensilla on the antennae. The mechanisms by which the atmospheric humidity stimulates the hygroreceptive cells remain elusive. Three models for humidity transduction have been proposed in which hygroreceptors operate either as mechanical hygrometers, evaporation detectors or psychrometers. Mechanical hygrometers are assumed to respond to the relative humidity, evaporation detectors to the saturation deficit and psychrometers to the temperature depression (the difference between wet-bulb and dry-bulb temperatures). The models refer to different ways of expressing humidity. This also means, however, that at different temperatures these different types of hygroreceptors indicate very different humidity conditions. The present study tested the adequacy of the three models on the cockroach’s moist and dry cells by determining whether the specific predictions about the temperature-dependence of the humidity responses are indeed observed. While in previous studies stimulation consisted of rapid step-like humidity changes, here we changed humidity slowly and continuously up and down in a sinusoidal fashion. The low rates of change made it possible to measure instantaneous humidity values based on UV-absorption and to assign these values to the hygroreceptive sensillum. The moist cell fitted neither the mechanical hygrometer nor the evaporation detector model: the temperature dependence of its humidity responses could not be attributed to relative humidity or to saturation deficit, respectively. The psychrometer model, however, was verified by the close relationships of the moist cell’s response with the wet-bulb temperature and the dry cell’s response with the dry-bulb temperature. Thus, the hygroreceptors respond to evaporation and the resulting cooling due to the wetness or dryness of the air. The drier the ambient air (absolutely) and the higher the temperature, the greater the evaporative temperature depression and the power to desiccate. PMID:23342058
The evaporative function of cockroach hygroreceptors.
Tichy, Harald; Kallina, Wolfgang
2013-01-01
Insect hygroreceptors associate as antagonistic pairs of a moist cell and a dry cell together with a cold cell in small cuticular sensilla on the antennae. The mechanisms by which the atmospheric humidity stimulates the hygroreceptive cells remain elusive. Three models for humidity transduction have been proposed in which hygroreceptors operate either as mechanical hygrometers, evaporation detectors or psychrometers. Mechanical hygrometers are assumed to respond to the relative humidity, evaporation detectors to the saturation deficit and psychrometers to the temperature depression (the difference between wet-bulb and dry-bulb temperatures). The models refer to different ways of expressing humidity. This also means, however, that at different temperatures these different types of hygroreceptors indicate very different humidity conditions. The present study tested the adequacy of the three models on the cockroach's moist and dry cells by determining whether the specific predictions about the temperature-dependence of the humidity responses are indeed observed. While in previous studies stimulation consisted of rapid step-like humidity changes, here we changed humidity slowly and continuously up and down in a sinusoidal fashion. The low rates of change made it possible to measure instantaneous humidity values based on UV-absorption and to assign these values to the hygroreceptive sensillum. The moist cell fitted neither the mechanical hygrometer nor the evaporation detector model: the temperature dependence of its humidity responses could not be attributed to relative humidity or to saturation deficit, respectively. The psychrometer model, however, was verified by the close relationships of the moist cell's response with the wet-bulb temperature and the dry cell's response with the dry-bulb temperature. Thus, the hygroreceptors respond to evaporation and the resulting cooling due to the wetness or dryness of the air. The drier the ambient air (absolutely) and the higher the temperature, the greater the evaporative temperature depression and the power to desiccate.
A Study on Mutil-Scale Background Error Covariances in 3D-Var Data Assimilation
NASA Astrophysics Data System (ADS)
Zhang, Xubin; Tan, Zhe-Min
2017-04-01
The construction of background error covariances is a key component of three-dimensional variational data assimilation. There are different scale background errors and interactions among them in the numerical weather Prediction. However, the influence of these errors and their interactions cannot be represented in the background error covariances statistics when estimated by the leading methods. So, it is necessary to construct background error covariances influenced by multi-scale interactions among errors. With the NMC method, this article firstly estimates the background error covariances at given model-resolution scales. And then the information of errors whose scales are larger and smaller than the given ones is introduced respectively, using different nesting techniques, to estimate the corresponding covariances. The comparisons of three background error covariances statistics influenced by information of errors at different scales reveal that, the background error variances enhance particularly at large scales and higher levels when introducing the information of larger-scale errors by the lateral boundary condition provided by a lower-resolution model. On the other hand, the variances reduce at medium scales at the higher levels, while those show slight improvement at lower levels in the nested domain, especially at medium and small scales, when introducing the information of smaller-scale errors by nesting a higher-resolution model. In addition, the introduction of information of larger- (smaller-) scale errors leads to larger (smaller) horizontal and vertical correlation scales of background errors. Considering the multivariate correlations, the Ekman coupling increases (decreases) with the information of larger- (smaller-) scale errors included, whereas the geostrophic coupling in free atmosphere weakens in both situations. The three covariances obtained in above work are used in a data assimilation and model forecast system respectively, and then the analysis-forecast cycles for a period of 1 month are conducted. Through the comparison of both analyses and forecasts from this system, it is found that the trends for variation in analysis increments with information of different scale errors introduced are consistent with those for variation in variances and correlations of background errors. In particular, introduction of smaller-scale errors leads to larger amplitude of analysis increments for winds at medium scales at the height of both high- and low- level jet. And analysis increments for both temperature and humidity are greater at the corresponding scales at middle and upper levels under this circumstance. These analysis increments improve the intensity of jet-convection system which includes jets at different levels and coupling between them associated with latent heat release, and these changes in analyses contribute to the better forecasts for winds and temperature in the corresponding areas. When smaller-scale errors are included, analysis increments for humidity enhance significantly at large scales at lower levels to moisten southern analyses. This humidification devotes to correcting dry bias there and eventually improves forecast skill of humidity. Moreover, inclusion of larger- (smaller-) scale errors is beneficial for forecast quality of heavy (light) precipitation at large (small) scales due to the amplification (diminution) of intensity and area in precipitation forecasts but tends to overestimate (underestimate) light (heavy) precipitation .
NASA Astrophysics Data System (ADS)
Schoof, J. T.
2017-12-01
Extreme temperatures affect society in multiple ways, but the impacts are often different depending on the concurrent humidity. For example, the greatest impacts on human morbidity and mortality result when the temperature and humidity are both elevated. Conversely, high temperatures coupled with low humidity often lead to agricultural impacts resulting in lower yields. Despite the importance of humidity in determining heat wave impacts, relatively few students of future temperature extremes have also considered possible changes in humidity. In a recent study, we investigated recent historical changes in the frequency and intensity and low humidity and high humidity extreme temperature events using a framework based on isobaric equivalent temperature. Here, we extend this approach to climate projections from CMIP5 models to explore possible regional changes in extreme heat characteristics. After using quantile mapping to bias correct and downscale the CMIP5 model outputs, we analyze results from two future periods (2031-2055 and 2061-2085) and two representative concentration pathways, RCP 4.5 and RCP 8.5, corresponding to moderate and high levels of radiative forcing from greenhouse gases. For each of seven US regions, we consider changes in extreme temperature frequency, changes in the proportion of extreme temperature days characterized by high humidity, and changes in the magnitude of temperature and humidity on extreme temperature days.
Kim, Jung-Hyun; Powell, Jeffery B; Roberge, Raymond J; Shepherd, Angie; Coca, Aitor
2014-01-01
The purpose of this study was to evaluate the predictive capability of fabric Total Heat Loss (THL) values on thermal stress that Personal Protective Equipment (PPE) ensemble wearers may encounter while performing work. A series of three tests, consisting of the Sweating Hot Plate (SHP) test on two sample fabrics and the Sweating Thermal Manikin (STM) and human performance tests on two single-layer encapsulating ensembles (fabric/ensemble A = low THL and B = high THL), was conducted to compare THL values between SHP and STM methods along with human thermophysiological responses to wearing the ensembles. In human testing, ten male subjects performed a treadmill exercise at 4.8 km and 3% incline for 60 min in two environmental conditions (mild = 22°C, 50% relative humidity (RH) and hot/humid = 35°C, 65% RH). The thermal and evaporative resistances were significantly higher on a fabric level as measured in the SHP test than on the ensemble level as measured in the STM test. Consequently the THL values were also significantly different for both fabric types (SHP vs. STM: 191.3 vs. 81.5 W/m(2) in fabric/ensemble A, and 909.3 vs. 149.9 W/m(2) in fabric/ensemble B (p < 0.001). Body temperature and heart rate response between ensembles A and B were consistently different in both environmental conditions (p < 0.001), which is attributed to significantly higher sweat evaporation in ensemble B than in A (p < 0.05), despite a greater sweat production in ensemble A (p < 0.001) in both environmental conditions. Further, elevation of microclimate temperature (p < 0.001) and humidity (p < 0.01) was significantly greater in ensemble A than in B. It was concluded that: (1) SHP test determined THL values are significantly different from the actual THL potential of the PPE ensemble tested on STM, (2) physiological benefits from wearing a more breathable PPE ensemble may not be feasible with incremental THL values (SHP test) less than approximately 150-200 W·m(2), and (3) the effects of thermal environments on a level of heat stress in PPE ensemble wearers are greater than ensemble thermal characteristics.
Undergraduate Research Program in Atmospheric Science: Houston Ozone Studies
NASA Astrophysics Data System (ADS)
Morris, P. A.; Balimuttajjo, M.; Damon, D.; Herridge, A.; Hromis, A. G.; Litwin, D.; Wright, J. M.
2011-12-01
The Minority University Consortium for Earth and Space Sciences (MUCESS) composed of the University of Houston-Downtown (UHD), Medgar Evers College (City University of New York), South Carolina State University, is an undergraduate atmospheric science program funded by NSF. The program's goal is to increase the participation of minority universities in STEM activities and careers by providing students with the knowledge and skills needed to perform weather balloon launches, interpret ozone and temperature variations in the troposphere and stratosphere. Ozone profiles up to 30 km altitude are obtained via an instrument payload attached to a weather balloon. The payload instrumentation consists of an EN-SCI ECC ozonesonde and an iMET radiosonde. The data is transmitted to a base station in real time and includes pressure, temperature, humidity, and GPS coordinates This presentation is directed towards comparing our 2011 Houston data to data that either UHD or the University of Houston (UH) has collected. Our launches are primarily on Sunday, and UH's on Friday. Our primary objective is to identify ground level ozone variations on Sunday and compare with weekday levels as tropospheric ozone is largely controlled by anthropogenic activities. Ozone levels vary depending on the time of year, temperature, rain, wind direction, chemical plant activities, private and commercial traffic patterns.etc. Our limited Friday launches, supported by UH data, indicate that ground level ozone is generally elevated in contrast to Sunday data, For example, our Friday July 2011 launch detected elevated low-altitude ozone levels with ground level ozone levels of 42 nb that increased to 46 nb from 500 m to 1 km. Other peaks are at 2.7 km (44 nb) and 6km (41 nb), decreasing to 17 nb at the tropopause (12 km). Overall, Sunday low altitude ozone levels are generally lower. Our Sunday ground level ozone data ranges from a low of 25 nb on July 11 to a high of 50 nb on August 1. A combination of wind direction and industrial output variations are likely responsible for the these differences. On July 11, ozone levels decrease slightly from the ground-level values up to 2 km. Above this altitude, significant fluctuations in ozone values ranging from 20 to 40nb occur from 2 to 7 km. These fluctuations inversely correlate with humidity. Relative humidity of 20% corresponding to high ozone and 60% humidity values for low ozone. This probably reflects dilution of ozone with water vapor. In contrast, on August 1 ozone values decrease abruptly at 800 meters to 35 nb with only minor fluctuations with increasing altitude to the tropopause. For both days, the change from ground-level ozone values to the higher altitude patterns correlates with a slight temperature inversion. The Stratospheric ozone also shows a significant contrast on the two days. At 22 km altitude an ozone value of 150 nb is seen on August 1 cf the more typical 110 nb on July 11. The high value seen on August 1 is coincident with a major solar flare. These variations are typical of the range of stratospheric ozone levels seen throughout the year and may be attributable to short-term fluctuations in solar activity.
Effect of combined heat and radiation on microbial destruction
NASA Technical Reports Server (NTRS)
Fisher, D. A.; Pflug, I. J.
1977-01-01
A series of experiments at several levels of relative humidity and radiation dose rates was carried out using spores of Bacillus subtilis var. niger to evaluate the effect of heat alone, radiation alone, and a combination of heat and radiation. Combined heat and radiation treatment of microorganisms yields a destruction rate greater than the additive rates of the independent agents. The synergistic mechanism shows a proportional dependency on radiation dose rate, an Arrhenius dependence on temperature, and a dependency on relative humidity. Maximum synergism occurs under conditions where heat and radiation individually destroy microorganisms at approximately equal rates. Larger synergistic advantage is possible at low relative humidities rather than at high relative humidities.
The Response of Halophiles from the Atacama Desert to Humidity Changes
NASA Astrophysics Data System (ADS)
Allen, C.; Lera, M.; Chandra, J.; Webb, S.; Marcu, O.
2011-12-01
Survival of extremophiles in dry desert conditions implies adaptations to fluctuations in temperature, desiccation and radiation levels. The Atacama Desert, located in Chile, is the driest desert in the world. Despite the extreme desiccation conditions, cyanobacteria and heterotrophic bacteria are still able to survive in the evaporitic halite rocks that scatter the surface of the desert. The purpose of this study was to determine whether the extremely dry conditions cause cellular oxidative stress and to examine the adaptations that allow these extremophiles to survive. One potential adaptation is the import/export of redox metals which can scavenge reactive oxygen species, preventing oxidative stress. Another potential adaptation is based on changes in gene expression. Genes involved in the stress pathway, which help microorganisms combat intracellular oxidation and survive the harsh environment, are expected to have different expression levels based on the humidity and level of stress. The aims of this project were: 1. to characterize the elemental signature of cyanobacteria; 2. to identify possible intracellular elemental changes that may occur in response to changes in humidity; 3. to identify and quantify the expression of stress genes involved in the response to humidity changes. Here we will show the elemental composition of cells in the halite sample as determined by X-ray fluorescence imaging (microprobe beamline 2-3 at the Stanford Synchrotron Radiation Laboratory), real-time elemental fluctuations measured in live cells exposed to changing relative humidity values, and partial amplification of genes of interest using degenerate primers based on homologous cyanobacterial sequences.
Whey protein concentrate storage at elevated temperature and humidity
USDA-ARS?s Scientific Manuscript database
Dairy processors are finding new export markets for whey protein concentrate (WPC), a byproduct of cheesemaking, but they need to know if full-sized bags of this powder will withstand high temperature and relative humidity (RH) levels during unrefrigerated storage under tropical conditions. To answ...
Elevated relative humidity increases the incidence of boron deficiency in bedding plants
USDA-ARS?s Scientific Manuscript database
High relative humidity (RH) can cause lower concentrations of B accumulating in plants. The common greenhouse practice of controlling excess temperatures by applying mist irrigation to youngplants (plugs) results in elevated RH levels. Reports of boron (B) deficiency have become more prevalent ove...
Physiological and subjective responses to low relative humidity in young and elderly men.
Sunwoo, Yujin; Chou, Chinmei; Takeshita, Junko; Murakami, Motoko; Tochihara, Yutaka
2006-05-01
In order to compare the physiological and the subjective responses to low relative humidity of elderly and young men, we measured saccharin clearance time (SCT), frequency of blinking, hydration state of the skin, transepidermal water loss (TEWL), sebum level recovery and skin temperatures as physiological responses. We asked subjects to evaluate thermal, dryness and comfort sensations as subjective responses using a rating scale. Eight non-smoking healthy male students (21.7+/-0.8 yr) and eight non-smoking healthy elderly men (71.1+/-4.1 yr) were selected. The pre-room conditions were maintained at an air temperature (Ta) of 25 degrees C and a relative humidity (RH) of 50%. The test-room conditions were adjusted to provide 25 degrees C Ta and RH levels of 10%, 30% and 50%. RH had no effect on the activity of the sebaceous gland or change of mean skin temperature. SCT of the elderly group under 10% RH was significantly longer than that of the young group. In particular, considering the SCT change, the nasal mucous membrane seems to be affected more in the elderly than in the young in low RH. Under 30% RH, the eyes and skin become dry, and under 10% RH the nasal mucous membrane becomes dry as well as the eyes and skin. These findings suggested that to avoid dryness of the eyes and skin, it is necessary to maintain greater than 30% RH, and to avoid dryness of the nasal mucous membrane, it is necessary to maintain greater than 10% RH. On the thermal sensation of the legs, at the lower humidity level, the elderly group felt cooler than the young group. On the dry sensation of the eyes and throat, the young group felt drier than the elderly group at the lower humidity levels. From the above results, the elderly group had difficulty in feeling dryness in the nasal mucous membrane despite being easily affected by low humidity. On the other hand, the young group felt the change of humidity sensitively despite not being severely affected by low humidity. Ocular mucosa and physiology of skin by dryness showed no difference by age. In the effect of longer exposure (180 min.) to low RH, only TEWL showed a slight decrease after 120 minutes in 30% RH, and all the measured results showed no noticeable differences compared with the result at 120 minutes.
Lepeule, Johanna; Litonjua, Augusto A; Gasparrini, Antonio; Koutrakis, Petros; Sparrow, David; Vokonas, Pantel S; Schwartz, Joel
2018-04-21
While the effects of weather variability on cardio-respiratory mortality are well described, research examining the effects on morbidity, especially for vulnerable populations, is warranted. We investigated the associations between lung function and outdoor temperature (T in Celsius degrees (°C)) and relative humidity (RH), in a cohort of elderly men, the Normative Aging Study. Our study included 1103 participants whose forced vital capacity (FVC), forced expiratory volume in one second (FEV 1 ), and weather exposures were assessed one to five times during the period 1995-2011 (i.e. 3162 observations). Temperature and relative humidity were measured at one location 4 h to 7 days before lung function tests. We used linear mixed-effects models to examine the associations with outdoor T and RH. A 5-degree increase in the 3-day moving average T was associated with a significant 0.7% decrease (95%CI: -1.24, -0.20) in FVC and a 5% increase in the 7-day moving average RH was associated with a significant 0.2% decrease (95%CI: -0.40, -0.02) in FVC and FEV 1 . The associations with T were greater when combined with higher exposures of black carbon with a 1.6% decrease (95%CI -2.2; -0.9) in FVC and a 1% decrease (95%CI -1.7; -0.4) in FEV 1 . The relationships between T and RH and lung function were linear. No synergistic effect of T and RH was found. Heat and lung function are two predictors of mortality. Our findings suggest that increases in temperature and relative humidity are related to decreases in lung function, and such observations might be amplified by high black carbon levels. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Haghighat, Fariborz; Lee, Chang-Seo; Pant, Bhuvan; Bolourani, Golnoush; Lakdawala, Ness; Bastani, Arash
There are increased demands for security, sustainability and indoor air quality in today's building design, construction, operation and maintenance. Installation of air cleaning systems can improve the indoor air quality by reducing the air pollution levels, and enhance the building security against sudden release of chemical and/or biological agents. At the same time, air cleaning techniques may reduce the building energy consumption by reducing the outdoor air supply rate, hence lowering the needs for conditioning of outdoor air. While the air filtration of particulate matter is well standardized, the standards against which the performance of air cleaning for gaseous contaminants is measured or classified are still under development. This study examined the performance of various granular activated carbons (GACs) for the removal of volatile organic compounds (VOCs) from mechanically ventilated buildings. Eight different GACs (three virgin and five impregnated) were tested against toluene using a dynamic test system. The virgin GACs showed better performance than impregnated ones, the percentage and the type of impregnation affected the removal efficiencies. Tests were also conducted with selected GACs against toluene, cyclohexane and ethyl acetate at relative humidity (RH) values of 30%, 50% and 70%. The effect of humidity was dependant on the VOC used. Both for toluene and cyclohexane, the removal efficiency decreased as RH increased. However, higher humidity showed a positive impact on the removal of ethyl acetate.
Cartledge, Benton T; Marcotte, Aurelie R; Herckes, Pierre; Anbar, Ariel D; Majestic, Brian J
2015-06-16
Iron is a limiting nutrient in about half of the world's oceans, and its most significant source is atmospheric deposition. To understand the pathways of iron solubilization during atmospheric transport, we exposed size segregated simulated marine aerosols to 5 ppm sulfur dioxide at arid (23 ± 1% relative humidity, RH) and marine (98 ± 1% RH) conditions. Relative iron solubility increased as the particle size decreased for goethite and hematite, while for magnetite, the relative solubility was similar for all of the fine size fractions (2.5-0.25 μm) investigated but higher than the coarse size fraction (10-2.5 μm). Goethite and hematite showed increased solubility at arid RH, but no difference (p > 0.05) was observed between the two humidity levels for magnetite. There was no correlation between iron solubility and exposure to SO2 in any mineral for any size fraction. X-ray absorption near edge structure (XANES) measurements showed no change in iron speciation [Fe(II) and Fe(III)] in any minerals following SO2 exposure. SEM-EDS measurements of SO2-exposed goethite revealed small amounts of sulfur uptake on the samples; however, the incorporated sulfur did not affect iron solubility. Our results show that although sulfur is incorporated into particles via gas-phase processes, changes in iron solubility also depend on other species in the aerosol.
Ou, Zong-Quan; Schmierer, David M; Strachan, Clare J; Rades, Thomas; McDowell, Arlene
2014-07-01
To investigate effects of different postharvest drying processes and storage conditions on key antioxidants in Sonchus oleraceus L. leaves. Fresh leaves were oven-dried (60°C), freeze-dried or air-dried (∼25°C) for 6 h, 24 h and 3 days, respectively. Design of experiments (DOE) was applied to study the stability of antioxidants (caftaric, chlorogenic and chicoric acids) in S. oleraceus leaves and leaf extracts stored at different temperatures (4, 25 and 50°C) and relative humidities (15%, 43% and 75%) for 180 days. The concentration of antioxidants was quantified by a HPLC-2,2'-diphenylpicrylhydrazyl post-column derivatisation method. Antioxidant activity was assessed by a cellular antioxidant activity assay. The three antioxidants degraded to unquantifiable levels after oven-drying. More than 90% of the antioxidants were retained by freeze-drying and air-drying. Both leaf and extract samples retained >90% of antioxidants, except those stored at 75% relative humidity. Leaf material had higher antioxidant concentrations and greater cellular antioxidant activity than corresponding extract samples. Freeze-drying and air-drying preserved more antioxidants in S. oleraceus than oven-drying. From DOE analysis, humidity plays an important role in degradation of antioxidants during storage. To preserve antioxidant activity, it is preferable to store S. oleraceus as dried leaf material. © 2014 Royal Pharmaceutical Society.
Season and humidity dependence of the effects of air pollution on COPD hospitalizations in Hong Kong
NASA Astrophysics Data System (ADS)
Qiu, Hong; Yu, Ignatius Tak Sun; Wang, Xiaorong; Tian, Linwei; Tse, Lap Ah; Wong, Tze Wai
2013-09-01
Associations between ambient pollution and respiratory morbidity including chronic obstructive pulmonary disease (COPD) have been confirmed. Weather factors, such as temperature, season and relative humidity (RH), may modify the effects of air pollution. This time series study was conducted to examine whether the effects of air pollution on emergency COPD hospital admissions in Hong Kong varied across seasons and RH levels, and explore the possible joint modification of season and RH on the effects of pollution. Data of daily air pollution concentrations mean temperature and RH, and COPD hospital admissions from 1998 to 2007 were collected. Generalized additive Poisson models with interaction terms were used to estimate the effects of pollution across seasons and RH levels. We observed an increase in the detrimental effects of air pollution in the cool season and on low humidity days. On the cool and dry days, a 10 μg m-3 increment of lag03 exposure was associated with an increase in emergency COPD admissions by 1.76% (95%CI: 1.19-2.34%), 3.43% (95%CI: 2.80-4.07%), and 1.99% (95%CI: 0.90-3.09%) for nitrogen dioxide (NO2), ozone (O3), and sulfur dioxide (SO2), respectively, all of which were statistically significantly higher than those on the other days. No consistent modification of weather factors was found for the effects of particles with an aerodynamic diameter less than 10 μm (PM10). The results suggested that season and RH jointly modified the effects of gaseous pollutants, resulting in increased emergency COPD hospitalizations on the cool and dry days.
Elevated Air Humidity Changes Soil Bacterial Community Structure in the Silver Birch Stand.
Truu, Marika; Ostonen, Ivika; Preem, Jens-Konrad; Lõhmus, Krista; Nõlvak, Hiie; Ligi, Teele; Rosenvald, Katrin; Parts, Kaarin; Kupper, Priit; Truu, Jaak
2017-01-01
Soil microbes play a fundamental role in forest ecosystems and respond rapidly to changes in the environment. Simultaneously with the temperature increase the climate change scenarios also predict an intensified hydrological cycle for the Baltic Sea runoff region. The aim of this study was to assess the effect of elevated air humidity on the top soil microbial community structure of a silver birch ( Betula pendula Roth.) stand by using a free air humidity manipulation facility (FAHM). The bacterial community structures of bulk soil and birch rhizosphere were analyzed using high-throughput sequencing of bacteria-specific16S rRNA gene fragments and quantification of denitrification related genes. The increased air humidity altered both bulk soil and rhizosphere bacterial community structures, and changes in the bacterial communities initiated by elevated air humidity were related to modified soil abiotic and biotic variables. Network analysis revealed that variation in soil bacterial community structural units is explained by altered abiotic conditions such as increased pH value in bulk soil, while in rhizosphere the change in absorptive root morphology had a higher effect. Among root morphological traits, the absorptive root diameter was strongest related to the bacterial community structure. The changes in bacterial community structures under elevated air humidity are associated with shifts in C, N, and P turnover as well as mineral weathering processes in soil. Increased air humidity decreased the nir and nosZ gene abundance in the rhizosphere bacterial community. The potential contribution of the denitrification to the N 2 O emission was not affected by the elevated air humidity in birch stand soil. In addition, the study revealed a strong link between the bacterial community structure, abundance of denitrification related genes, and birch absorptive root morphology in the ecosystem system adaptation to elevated air humidity.
Elevated Air Humidity Changes Soil Bacterial Community Structure in the Silver Birch Stand
Truu, Marika; Ostonen, Ivika; Preem, Jens-Konrad; Lõhmus, Krista; Nõlvak, Hiie; Ligi, Teele; Rosenvald, Katrin; Parts, Kaarin; Kupper, Priit; Truu, Jaak
2017-01-01
Soil microbes play a fundamental role in forest ecosystems and respond rapidly to changes in the environment. Simultaneously with the temperature increase the climate change scenarios also predict an intensified hydrological cycle for the Baltic Sea runoff region. The aim of this study was to assess the effect of elevated air humidity on the top soil microbial community structure of a silver birch (Betula pendula Roth.) stand by using a free air humidity manipulation facility (FAHM). The bacterial community structures of bulk soil and birch rhizosphere were analyzed using high-throughput sequencing of bacteria-specific16S rRNA gene fragments and quantification of denitrification related genes. The increased air humidity altered both bulk soil and rhizosphere bacterial community structures, and changes in the bacterial communities initiated by elevated air humidity were related to modified soil abiotic and biotic variables. Network analysis revealed that variation in soil bacterial community structural units is explained by altered abiotic conditions such as increased pH value in bulk soil, while in rhizosphere the change in absorptive root morphology had a higher effect. Among root morphological traits, the absorptive root diameter was strongest related to the bacterial community structure. The changes in bacterial community structures under elevated air humidity are associated with shifts in C, N, and P turnover as well as mineral weathering processes in soil. Increased air humidity decreased the nir and nosZ gene abundance in the rhizosphere bacterial community. The potential contribution of the denitrification to the N2O emission was not affected by the elevated air humidity in birch stand soil. In addition, the study revealed a strong link between the bacterial community structure, abundance of denitrification related genes, and birch absorptive root morphology in the ecosystem system adaptation to elevated air humidity. PMID:28421053
Partial oxidation of methane by pulsed corona discharges
NASA Astrophysics Data System (ADS)
Hoeben, W. F. L. M.; Boekhoven, W.; Beckers, F. J. C. M.; van Heesch, E. J. M.; Pemen, A. J. M.
2014-09-01
Pulsed corona-induced partial oxidation of methane in humid oxygen or carbon dioxide atmospheres has been investigated for future fuel synthesis applications. The obtained product spectrum is wide, i.e. saturated, unsaturated and oxygen-functional hydrocarbons. The generally observed methane conversion levels are 6-20% at a conversion efficiency of about 100-250 nmol J-1. The main products are ethane, ethylene and acetylene. Higher saturated hydrocarbons up to C6 have been detected. The observed oxygen-functional hydrocarbons are methanol, ethanol and lower concentrations of aldehydes, ketones, dimethylether and methylformate. Methanol seems to be exclusively produced with CH4/O2 mixtures at a maximum production efficiency of 0.35 nmol J-1. CH4/CO2 mixtures appear to yield higher hydrocarbons. Carboxylic acids appear to be mainly present in the aqueous reactor phase, possibly together with higher molecular weight species.
NASA Astrophysics Data System (ADS)
Leal-Junior, Arnaldo; Frizera, Anselmo; Marques, Carlos; Pontes, Maria José
2018-07-01
This paper presents the dynamic mechanical analysis (DMA) in polymer optical fibers (POFs) made of Polymethyl Methacrylate (PMMA) that were submitted to different thermal and chemical treatments, namely annealing and etching processes. The prepared samples were submitted to stress-strain cycles to evaluate the Young's modulus of each fiber. Also, test with constant stress and temperature variation were performed to estimate the thermal expansion coefficient of the fibers submitted to each thermal and chemical treatment. The samples were also tested under different temperature, humidity and strain cycle frequency conditions to analyze the variation of their mechanical properties with these parameters. Results show that the thermal and chemical treatments lead to a reduction of Young's modulus and an increase of the thermal expansion coefficient, which can produce sensors based on intensity variation or fiber Bragg grating with higher dynamic range, stress and temperature sensitivity. Furthermore, the etching and annealing resulted in fiber that presents lower Young's modulus variation with temperature, humidity and strain cycling frequency in most cases. However, the annealing made under water and the combinations of etching and annealing resulted in POFs with higher modulus variation with humidity, which enable their application as intensity variation or FBG-based sensors in humidity/moisture assessment.
Occurrence of human respiratory syncytial virus in summer in Japan.
Shobugawa, Y; Takeuchi, T; Hibino, A; Hassan, M R; Yagami, R; Kondo, H; Odagiri, T; Saito, R
2017-01-01
In temperate zones, human respiratory syncytial virus (HRSV) outbreaks typically occur in cold weather, i.e. in late autumn and winter. However, recent outbreaks in Japan have tended to start during summer and autumn. This study examined associations of meteorological conditions with the numbers of HRSV cases reported in summer in Japan. Using data from the HRSV national surveillance system and national meteorological data for summer during the period 2007-2014, we utilized negative binomial logistic regression analysis to identify associations between meteorological conditions and reported cases of HRSV. HRSV cases increased when summer temperatures rose and when relative humidity increased. Consideration of the interaction term temperature × relative humidity enabled us to show synergistic effects of high temperature with HRSV occurrence. In particular, HRSV cases synergistically increased when relative humidity increased while the temperature was ⩾28·2 °C. Seasonal-trend decomposition analysis using the HRSV national surveillance data divided by 11 climate divisions showed that summer HRSV cases occurred in South Japan (Okinawa Island), Kyushu, and Nankai climate divisions, which are located in southwest Japan. Higher temperature and higher relative humidity were necessary conditions for HRSV occurrence in summer in Japan. Paediatricians in temperate zones should be mindful of possible HRSV cases in summer, when suitable conditions are present.
[Luring effect of the fermented Laminaria japonica to Oncomelania hupensis].
Ma, An-ning; Ni, Hong; Wang, Wan-xian; Zhang, Yun; Geng, Peng
2010-02-01
To study the attraction effect of the food attractants on Oncomelania hupensis. Oncomelania snail food was prepared with the fermented kelp (Laminaria japonica) mixed with corn starch. Snails were fed with the food and kept for 12, 24, 36, and 48 h at 15, 25, 35 degrees C respectively. Meanwhile, snail-killing effect was tested by granules containing jack-in-the-pulpit (Arisama heterophyllum) with or without the fermented kelp under the condition of 25 degrees C, 30% or 60% soil humidity. The snail-attracting rate of the fermented kelp was affected by the temperature, highest under 25 degrees C and lowest under 35 degrees C at any time point, with a rate of 80.3% in 48 h at 25 degrees C which was higher than that of the control (17.0%) (P<0.01). The snail mortality rate in the group using jack-in-the-pulpit with fermented kelp (85.3%) was higher than that of the group without fermented kelp (26.8%) (P<0.05). The mortality under 60% of soil humidity was higher than that under 30% humidity (P<0.01). The fermented kelp shows a strong luring effect to the Oncomelania snails.
Manuyakorn, Wiparat; Padungpak, Savitree; Luecha, Orawin; Kamchaisatian, Wasu; Sasisakulporn, Cherapat; Vilaiyuk, Soamarat; Monyakul, Veerapol; Benjaponpitak, Suwat
2015-06-01
House dust mite avoidance is advised in dust mite sensitized patients to decrease the risk to develop allergic symptoms. Maintaining a relative humidity (RH) of less than 50% in households is recommended to prevent dust mite proliferation. To investigate the efficacy of a novel temperature and humidity machine to control the level of dust mite allergens and total nasal symptom score (TNSS) in dust mite sensitized allergic rhinitis children. Children (8-15 years) with dust mite sensitized persistent allergic rhinitis (AR) were enrolled. The temperature and humidity control machine was installed in the bedroom where the enrolled children stayed for 6 months. TNSS was assessed before and every month after machine set up and the level of dust mite allergen (Der p 1 and Der f 1) from the mattress were measured before and every 2 months after machine set up using enzyme-linked immunosorbent assay (ELISA). A total of 7 children were enrolled. Noticeable reduction of Der f 1 was observed as early as 2 months after installing the machine, but proper significant differences appeared 4 months after and remained low until the end of the experiment (p <0.05). Although no correlation was observed between TNSS and the level of dust mite allergens, there was a significant reduction in TNSS at 2 and 4 months (p <0.05) and 70% of the patients were able to stop using their intranasal corticosteroids by the end of the experiment. The level of house dust mite in mattresses was significantly reduced after using the temperature and humidity control machine. This machine may be used as an effective tool to control clinical symptoms of dust mite sensitized AR children.
[Examination of upper airway function using the dew point hygrometer with semiconductor detector].
Weremczuk, Jerzy; Paczesny, Daniel; Rapiejko, Piotr; Jachowicz, Ryszard; Jurkiewicz, Dariusz
2005-09-01
The nasal mucosa with blood capillary network has a remarkable role in respiration process. The most important nose functions are heating and humidifying to optimal level of reaching throat and lungs air and partly absorption of humidity and temperature from expired air. Variations of humidifying and heating processes can invoke some upper airways disorders. The paper presents dew point hygrometer which was specially design for laryngological purposes. The hygrometer can measure dynamic changes of humidity in upper airways. The device is fully automated, easy to operate and can communicate with external personal computer. Database application allows saving patient data with archive examination results and can display them easily. During ongoing clinical tests, still increasing amount of data will allow precisely investigate correlations between humidifying process and some diseases. The main advantage of the device is a short response time on humidity changing. The number of readings (detections) can reach 5 readings per second (slightly depending on humidity level) which is much faster than in available on the market hygrometers with sorption sensors. The paper also presents some results obtained in group of healthy volunteers and one patient with tracheostomy The tests figured out actual humidity in certain parts of upper airways: nose, throat, trachea in breathing cycles under various surrounding conditions. The constructed hygrometer can be used for air humidity measurement in upper airways during some diseases and for evaluation of an influence of some drugs and environmental conditions changing on air upper ways mucosa.
NASA Astrophysics Data System (ADS)
Mao, H.; Talbot, R.; Hegarty, J.; Koermer, J.
2012-05-01
Long-term continuous measurements of gaseous elemental mercury (Hg0), reactive gaseous mercury (RGM), and particulate phase mercury (HgP) were conducted at coastal (Thompson Farm, denoted as TF), marine (Appledore Island, denoted as AI), and elevated inland rural (Pac Monadnock, denoted as PM) monitoring sites of the AIRMAP Observing Network. Diurnal, seasonal, annual, and interannual variability in Hg0, RGM, and HgP from the three distinctly different environments were characterized and compared in Part 1. Here in Part 2 relationships between speciated mercury (i.e., Hg0, RGM, and HgP) and climate variables (e.g., temperature, wind speed, humidity, solar radiation, and precipitation) were examined. The best point-to-point correlations were found between Hg0 and temperature in summer at TF and spring at PM, but there was no similar correlation at AI. Subsets of data demonstrated regional impacts of episodic dynamic processes such as strong cyclonic systems on ambient levels of Hg0 at all three sites, possibly through enhanced oceanic evasion of Hg0. A tendency of higher levels of RGM and HgP was identified in spring and summer under sunny conditions in all environments. Specifically, the 10th, 25th, median, 75th, and 90th percentile mixing ratios of RGM and HgP increased with stronger solar radiation at both the coastal and marine sites. These metrics decreased with increasing wind speed at AI indicating enhanced loss of RGM and HgP through deposition. RGM and HgP levels correlated with temperature positively in spring, summer and fall at the coastal and marine locations. At the coastal site relationships between RGM and relative humidity suggested a clear decreasing tendency in all metrics from <40% to 100% relative humidity in all seasons especially in spring, compared to less variability in the marine environment. The effect of precipitation on RGM at coastal and marine locations was similar. At the coastal site, RGM levels were a factor of 3-4 to two orders of magnitude higher under dry conditions than rainy conditions in all seasons. In winter RGM mixing ratios appeared to be mostly above the limit of detection (LOD) during snowfalls suggesting less scavenging efficiency of snow. Mixing ratios of HgP at the coastal and marine sites remained above the LOD under rainy conditions. Precipitation had negligible impact on the magnitude and pattern of diurnal variation of HgP in all seasons in the marine environment.
USDA-ARS?s Scientific Manuscript database
Low relative humidity (RH) levels (=63%) have been previously shown to be a determining factor in the survival of southern cattle fever tick, Rhipicephalus microplus, larvae, regardless of temperature. Supporting this observation, large larval clusters can retain more water than isolated larvae. Th...
Huang, Jiaoyan; Gustin, Mae Sexauer
2015-05-19
Quantifying the concentration of gaseous oxidized mercury (GOM) and identifying the chemical compounds in the atmosphere are important for developing accurate local, regional, and global biogeochemical cycles. The major hypothesis driving this work was that relative humidity affects collection of GOM on KCl-coated denuders and nylon membranes, both currently being applied to measure GOM. Using a laboratory manifold system and ambient air, GOM capture efficiency on 3 different collection surfaces, including KCl-coated denuders, nylon membranes, and cation-exchange membranes, was investigated at relative humidity ranging from 25 to 75%. Recovery of permeated HgBr2 on KCl-coated denuders declined by 4-60% during spikes of relative humidity (25 to 75%). When spikes were turned off GOM recoveries returned to 60 ± 19% of permeated levels. In some cases, KCl-coated denuders were gradually passivated over time after additional humidity was applied. In this study, GOM recovery on nylon membranes decreased with high humidity and ozone concentrations. However, additional humidity enhanced GOM recovery on cation-exchange membranes. In addition, reduction and oxidation of elemental mercury during experiments was observed. The findings in this study can help to explain field observations in previous studies.
NASA Astrophysics Data System (ADS)
Pentjuss, E.; Lusis, A.; Gabrusenoks, J.; Bajars, G.
2015-03-01
Na-Al-Si glass fabrics fibres contain Na+ ions that diffuse to its surface and along with CO2 and H2O from atmosphere create here the shell of carbonate hydrates. The heating of fabric leads to weight loss by evolving these substances. In this work the results of weight recovery study at room relative humidity (20% - 50%) and elevated humidity (near 70%) of fabrics after its heating at different temperatures (70°C - 150°C) are compared. The experiments shoved the different weight recovery kinetics. The initial exponential stages up to 0.3 h - 0.5 h of the both recoveries are associated with water absorption and differ by its levels. In a case of lower environment humidity the later weight increase are restricted by its value, but at an elevated humidity has a maximum and followed weight increase. The reasons of observed differences are discussed.
Influence of Relative Humidity on AC Corona Discharge from Algae Attached on the Silicone Rubber
NASA Astrophysics Data System (ADS)
Sato, Daisuke; Hara, Yoshiaki; Kokufu, Morihide; Higashiyama, Yoshio
To make clear the influence of algae growth at the surface of a polymer insulator in a practical transmission line, the characteristics of ac corona discharge from an aggregate algae particle were investigated. The aggregate algae particle was made of Protococcus viridis. Corona onset voltage from an aggregate algae particle was decreased as relative humidity increased. Under the condition of relatively higher relative humidity, luminous channel of corona discharge became more strongly and the number of corona pulses in the current waveform was increased. For an aggregate algae particle contaminated with sea salt including MgCl2, corona onset voltage decreased drastically at relative humidity above 40%. This property would result from deliquescence of MgCl2. Corona discharge was strongly affected by existence of MgCl2 in an aggregate algae particle. Surface resistance of algae attached to the surface of the silicone rubber sheet decreased in fourth figures for relative humidity from 20 to 90%. Therefore, the existence of algae on the polymer insulator inevitably affects the electric property and the surface property of the polymer insulator.
Opdahl, Aric; Kim, Seong H; Koffas, Telly S; Marmo, Chris; Somorjai, Gabor A
2003-10-01
The surface mechanical properties of poly(hydroxyethyl)methacrylate (pHEMA)-based contact lenses were monitored as a function of humidity by atomic force microscopy (AFM). Surface viscoelastic and adhesion values were extracted from AFM force versus distance interaction curves and were found to be strongly dependent on the bulk water content of the lens and on the relative humidity. At low relative humidity, 40-50%, the dehydration rate from the surface is faster than the hydration rate from the bulk, leading to a rigid surface region that has mechanical properties similar to those measured on totally dehydrated lenses. At relative humidity values > 60%, the dehydration rate from the lens surface rapidly decreases, leading to higher surface water content and a softer surface region. The results indicate that, in an ocular environment, although the bulk of the pHEMA contact lens is hydrated, the surface region may be in a transition between a dehydrated glassy state and a hydrated rubbery state. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 350-356, 2003
NASA Astrophysics Data System (ADS)
Dirpan, Andi; Tahir Sapsal, Muhammad; Kadir Muhammad, Abdul; Tahir, Mulyati M.; Rahimuddin
2017-12-01
Zero Energy Cool Chamber (ZECC) is a cooling chamber for storing fruits and vegetables from the viewpoints of low cost and energy savings. The aim of the present study is to evaluate temperature and relative humidity (RH) on two types of zero energy cool chamber (ZECC) in South Sulawesi, Indonesia. The first category was placed underground while the second category was on the surface. Then, the performance of the ZECC was measured by calculating temperature and relative humidity. The results show that the ZECC was constructed on the surface produce lower temperature and higher RH compare to ZECC which placed underground. In average, the temperature in the outside (28.0°C) is greater than in inside (26.2°C) of the ZECC. On the other hand, the relative humidity in the outside (72.9%) is less than in inside (87.2%) of the ZECC. It was concluded that the ZECC where was constructed on the surface is more suitable than ZECC in the underground for decreasing temperature and increasing relative humidity.
Dropwise condensation dynamics in humid air
NASA Astrophysics Data System (ADS)
Castillo Chacon, Julian Eduardo
Dropwise condensation of atmospheric water vapor is important in multiple practical engineering applications. The roles of environmental factors and surface morphology/chemistry on the condensation dynamics need to be better understood to enable efficient water-harvesting, dehumidication, and other psychrometric processes. Systems and surfaces that promote faster condensation rates and self-shedding of condensate droplets could lead to improved mass transfer rates and higher water yields in harvesting applications. The thesis presents the design and construction of an experimental facility that allows visualization of the condensation process as a function of relative humidity. Dropwise condensation experiments are performed on a vertically oriented, hydrophobic surface at a controlled relative humidity and surface subcooling temperature. The distribution and growth of water droplets are monitored across the surface at different relative humidities (45%, 50%, 55%, and 70%) at a constant surface subcooling temperature of 15 °C below the ambient temperature. The droplet growth dynamics exhibits a strong dependency on relative humidity in the early stages during which there is a large population of small droplets on the surface and single droplet growth dominates over coalescence effects. At later stages, the dynamics of droplet growth is insensitive to relative humidity due to the dominance of coalescence effects. The overall volumetric rate of condensation on the surface is also assessed as a function of time and ambient relative humidity. Low relative humidity conditions not only slow the absolute rate of condensation, but also prolong an initial transient regime over which the condensation rate remains significantly below the steady-state value. The current state-of-the-art in dropwise condensation research indicates the need for systematic experimental investigations as a function of relative humidity. The improved understanding of the relative humidity effects on the growth of single and distributed droplets offered in this thesis can improve the prediction of heat and mass transfer during dropwise condensation of humid air under differing environmental conditions. This knowledge can be used to engineer condenser systems and surfaces that are adapted for local ambient relative humidity and temperature conditions.
Guo, W J; Zhen, L; Zhang, J X; Lian, S; Si, H F; Guo, J R; Yang, H M
2017-10-01
This study was conducted to evaluate the effects of supplemental rumen-protected capsule (RPC) on animal performance, serological indicators, and serum heat shock protein 70 (HSP70) of lactating Holstein cows under heat stress (HS). During summer months, 30 healthy multiparous lactating Holstein cows with a parity number of 3.1 ± 0.44, 70 ± 15 d in milk, an average body weight of 622 ± 62kg, and an average milk yield of 32.28 ± 0.96kg/d, were used. The cows were randomly allocated to two groups: a control group and an RPC-supplemented group (0.13373kg K 2 SO 4 , 0.02488kg vitamin C, 0.021148kg niacin, and 0.044784kggamma-aminobutyric acid per cow). During the 42-d experiment, ambient air temperature and relative humidity inside and outside the barn were recorded hourly every day for the determination of temperature-humidity index (THI). Milk and blood samples were collected every week, and body weight and body condition scoring were measured on day 0. Based on the THI values, the animals had moderate HS. On day 42, the RPC group had lower HSP70, adrenocorticotropic hormone (P = 0.0001), lactate dehydrogenase (P = 0.0338), and IL-6 (P = 0.0724) levels than the control group, with no significant differences in creatine kinase, glucocorticoid, or IL-2 levels. Milk yield, energy-corrected milk, and dry matter intake were higher in RPC than in the control group (P = 0.0196). There were no significant differences in milk fat or daily protein levels between the two groups; however, daily protein and milk fat levels were higher in the RPC group than in the control group (P = 0.0114 and P = 0.0665, respectively). Somatic cell counts were no different between the two groups. In conclusion, RPC may alleviate HS and improve dairy cow performance. Copyright © 2017. Published by Elsevier Ltd.
Yu, Ya-Jen; Hearon, Keith; Wilson, Thomas S; Maitland, Duncan J
2011-08-01
The effect of moisture absorption on the glass transition temperature (T(g)) and stress/strain behavior of network polyurethane shape memory polymer (SMP) foams has been investigated. With our ultimate goal of engineering polyurethane SMP foams for use in blood contacting environments, we have investigated the effects of moisture exposure on the physical properties of polyurethane foams. To our best knowledge, this study is the first to investigate the effects of moisture absorption at varying humidity levels (non-immersion and immersion) on the physical properties of polyurethane SMP foams. The SMP foams were exposed to differing humidity levels for varying lengths of time, and they exhibited a maximum water uptake of 8.0% (by mass) after exposure to 100% relative humidity for 96 h. Differential scanning calorimetry results demonstrated that water absorption significantly decreased the T(g) of the foam, with a maximum water uptake shifting the T(g) from 67 °C to 5 °C. Samples that were immersed in water for 96 h and immediately subjected to tensile testing exhibited 100% increases in failure strains and 500% decreases in failure stresses; however, in all cases of time and humidity exposure, the plasticization effect was reversible upon placing moisture-saturated samples in 40% humidity environments for 24 h.
Yu, Ya-Jen; Hearon, Keith; Wilson, Thomas S.; Maitland, Duncan J.
2011-01-01
The effect of moisture absorption on the glass transition temperature (Tg) and stress/strain behavior of network polyurethane shape memory polymer (SMP) foams has been investigated. With our ultimate goal of engineering polyurethane SMP foams for use in blood contacting environments, we have investigated the effects of moisture exposure on the physical properties of polyurethane foams. To our best knowledge, this study is the first to investigate the effects of moisture absorption at varying humidity levels (non-immersion and immersion) on the physical properties of polyurethane SMP foams. The SMP foams were exposed to differing humidity levels for varying lengths of time, and they exhibited a maximum water uptake of 8.0% (by mass) after exposure to 100% relative humidity for 96 h. Differential scanning calorimetry results demonstrated that water absorption significantly decreased the Tg of the foam, with a maximum water uptake shifting the Tg from 67 °C to 5 °C. Samples that were immersed in water for 96 h and immediately subjected to tensile testing exhibited 100% increases in failure strains and 500% decreases in failure stresses; however, in all cases of time and humidity exposure, the plasticization effect was reversible upon placing moisture-saturated samples in 40% humidity environments for 24 h. PMID:21949469
NASA Astrophysics Data System (ADS)
Yu, Ya-Jen; Hearon, Keith; Wilson, Thomas S.; Maitland, Duncan J.
2011-08-01
The effect of moisture absorption on the glass transition temperature (Tg) and the stress/strain behavior of network polyurethane shape memory polymer (SMP) foams has been investigated. With our ultimate goal of engineering polyurethane SMP foams for use in blood-contacting environments, we have investigated the effects of moisture exposure on the physical properties of polyurethane foams. To the best of our knowledge, this study is the first to investigate the effects of moisture absorption at varying humidity levels (non-immersion and immersion) on the physical properties of polyurethane SMP foams. The SMP foams were exposed to differing humidity levels for varying lengths of time, and they exhibited a maximum water uptake of 8.0% (by mass) after exposure to 100% relative humidity for 96 h. Differential scanning calorimetry results demonstrated that water absorption significantly decreased the Tg of the foam, with a maximum water uptake shifting the Tg from 67 to 5 °C. Samples that were immersed in water for 96 h and immediately subjected to tensile testing exhibited 100% increases in failure strains and 500% decreases in failure stresses; however, in all cases of time and humidity exposure, the plasticization effect was reversible upon placing moisture-saturated samples in 40% humidity environments for 24 h.
Effects of Temperature and Relative Humidity on DNA Methylation
Bind, Marie-Abele; Zanobetti, Antonella; Gasparrini, Antonio; Peters, Annette; Coull, Brent; Baccarelli, Andrea; Tarantini, Letizia; Koutrakis, Petros; Vokonas, Pantel; Schwartz, Joel
2014-01-01
Background Previous studies have found relationships between DNA methylation and various environmental contaminant exposures. Associations with weather have not been examined. Because temperature and humidity are related to mortality even on non-extreme days, we hypothesized that temperature and relative humidity may affect methylation. Methods We repeatedly measured methylation on long interspersed nuclear elements (LINE-1), Alu, and 9 candidate genes in blood samples from 777 elderly men participating in the normative aging Study (1999–2009). We assessed whether ambient temperature and relative humidity are related to methylation on LINE-1 and Alu, as well as on genes controlling coagulation, inflammation, cortisol, DNA repair, and metabolic pathway. We examined intermediate-term associations of temperature, relative humidity, and their interaction with methylation, using distributed lag models. Results Temperature or relative humidity levels were associated with methylation on tissue factor (F3), intercellular adhesion molecule 1 (ICAM-1), toll-like receptor 2 (TRL-2), carnitine O-acetyltransferase (CRAT), interferon gamma (IFN-γ), inducible nitric oxide synthase (iNOS), and glucocorticoid receptor, LINE-1, and Alu. For instance, a 5°c increase in 3-week average temperature in ICAM-1 methylation was associated with a 9% increase (95% confidence interval: 3% to 15%), whereas a 10% increase in 3-week average relative humidity was associated with a 5% decrease (−8% to −1%). The relative humidity association with ICAM-1 methylation was stronger on hot days than mild days. Conclusions DNA methylation in blood cells may reflect biological effects of temperature and relative humidity. Temperature and relative humidity may also interact to produce stronger effects. PMID:24809956
Effects of temperature and relative humidity on DNA methylation.
Bind, Marie-Abele; Zanobetti, Antonella; Gasparrini, Antonio; Peters, Annette; Coull, Brent; Baccarelli, Andrea; Tarantini, Letizia; Koutrakis, Petros; Vokonas, Pantel; Schwartz, Joel
2014-07-01
Previous studies have found relationships between DNA methylation and various environmental contaminant exposures. Associations with weather have not been examined. Because temperature and humidity are related to mortality even on non-extreme days, we hypothesized that temperature and relative humidity may affect methylation. We repeatedly measured methylation on long interspersed nuclear elements (LINE-1), Alu, and 9 candidate genes in blood samples from 777 elderly men participating in the Normative Aging Study (1999-2009). We assessed whether ambient temperature and relative humidity are related to methylation on LINE-1 and Alu, as well as on genes controlling coagulation, inflammation, cortisol, DNA repair, and metabolic pathway. We examined intermediate-term associations of temperature, relative humidity, and their interaction with methylation, using distributed lag models. Temperature or relative humidity levels were associated with methylation on tissue factor (F3), intercellular adhesion molecule 1 (ICAM-1), toll-like receptor 2 (TRL-2), carnitine O-acetyltransferase (CRAT), interferon gamma (IFN-γ), inducible nitric oxide synthase (iNOS), and glucocorticoid receptor, LINE-1, and Alu. For instance, a 5°C increase in 3-week average temperature in ICAM-1 methylation was associated with a 9% increase (95% confidence interval: 3% to 15%), whereas a 10% increase in 3-week average relative humidity was associated with a 5% decrease (-8% to -1%). The relative humidity association with ICAM-1 methylation was stronger on hot days than mild days. DNA methylation in blood cells may reflect biological effects of temperature and relative humidity. Temperature and relative humidity may also interact to produce stronger effects.
Nilius, Georg; Domanski, Ulrike; Schroeder, Maik; Woehrle, Holger; Graml, Andrea; Franke, Karl-Josef
2018-01-01
Mucosal drying during continuous positive airway pressure (CPAP) therapy is problematic for many patients. This study assessed the influence of ambient relative humidity (rH) and air temperature (T) in winter and summer on mask humidity during CPAP, with and without mask leak, and with or without heated humidification ± heated tubing. CPAP (8 and 12 cmH 2 O) without humidification (no humidity [nH]), with heated humidification controlled by ambient temperature and humidity (heated humidity [HH]) and HH plus heated tubing climate line (CL), with and without leakage, were compared in 18 subjects with OSA during summer and winter. The absolute humidity (aH) and the T inside the mask during CPAP were significantly lower in winter versus summer under all applied conditions. Overall, absolute humidity differences between summer and winter were statistically significant in both HH and CL vs. nH ( p < 0.05) in the presence and absence of mouth leak. There were no significant differences in aH between HH and CL. However, in-mask temperature during CL was higher ( p < 0.05) and rH lower than during HH. In winter, CPAP with CL was more likely to keep rH constant at 80% than CPAP without humidification or with standard HH. Clinically-relevant reductions in aH were documented during CPAP given under winter conditions. The addition of heated humidification, using a heated tube to avoid condensation is recommended to increase aH, which could be useful in CPAP users complaining of nose and throat symptoms.
Mask humidity during CPAP: influence of ambient temperature, heated humidification and heated tubing
Nilius, Georg; Domanski, Ulrike; Schroeder, Maik; Woehrle, Holger; Graml, Andrea; Franke, Karl-Josef
2018-01-01
Purpose Mucosal drying during continuous positive airway pressure (CPAP) therapy is problematic for many patients. This study assessed the influence of ambient relative humidity (rH) and air temperature (T) in winter and summer on mask humidity during CPAP, with and without mask leak, and with or without heated humidification ± heated tubing. Methods CPAP (8 and 12 cmH2O) without humidification (no humidity [nH]), with heated humidification controlled by ambient temperature and humidity (heated humidity [HH]) and HH plus heated tubing climate line (CL), with and without leakage, were compared in 18 subjects with OSA during summer and winter. Results The absolute humidity (aH) and the T inside the mask during CPAP were significantly lower in winter versus summer under all applied conditions. Overall, absolute humidity differences between summer and winter were statistically significant in both HH and CL vs. nH (p < 0.05) in the presence and absence of mouth leak. There were no significant differences in aH between HH and CL. However, in-mask temperature during CL was higher (p < 0.05) and rH lower than during HH. In winter, CPAP with CL was more likely to keep rH constant at 80% than CPAP without humidification or with standard HH. Conclusion Clinically-relevant reductions in aH were documented during CPAP given under winter conditions. The addition of heated humidification, using a heated tube to avoid condensation is recommended to increase aH, which could be useful in CPAP users complaining of nose and throat symptoms. PMID:29750062
The Effects of Abiotic Factors on Induced Volatile Emissions in Corn Plants1
Gouinguené, Sandrine P.; Turlings, Ted C.J.
2002-01-01
Many plants respond to herbivory by releasing a specific blend of volatiles that is attractive to natural enemies of the herbivores. In corn (Zea mays), this induced odor blend is mainly composed of terpenoids and indole. The induced signal varies with plant species and genotype, but little is known about the variation due to abiotic factors. Here, we tested the effect of soil humidity, air humidity, temperature, light, and fertilization rate on the emission of induced volatiles in young corn plants. Each factor was tested separately under constant conditions for the other factors. Plants released more when standing in dry soil than in wet soil, whereas for air humidity, the optimal release was found at around 60% relative humidity. Temperatures between 22°C and 27°C led to a higher emission than lower or higher temperatures. Light intensity had a dramatic effect. The emission of volatiles did not occur in the dark and increased steadily with an increase in the light intensity. An experiment with an unnatural light-dark cycle showed that the release was fully photophase dependent. Fertilization also had a strong positive effect; the emission of volatiles was minimal when plants were grown under low nutrition, even when results were corrected for plant biomass. Changes in all abiotic factors caused small but significant changes in the relative ratios among the different compounds (quality) in the induced odor blends, except for air humidity. Hence, climatic conditions and nutrient availability can be important factors in determining the intensity and variability in the release of induced plant volatiles. PMID:12114583
Hass, Alisa L.; Ellis, Kelsey N.; Reyes Mason, Lisa; Hathaway, Jon M.; Howe, David A.
2016-01-01
Daily weather conditions for an entire city are usually represented by a single weather station, often located at a nearby airport. This resolution of atmospheric data fails to recognize the microscale climatic variability associated with land use decisions across and within urban neighborhoods. This study uses heat index, a measure of the combined effects of temperature and humidity, to assess the variability of heat exposure from ten weather stations across four urban neighborhoods and two control locations (downtown and in a nearby nature center) in Knoxville, Tennessee, USA. Results suggest that trees may negate a portion of excess urban heat, but are also associated with greater humidity. As a result, the heat index of locations with more trees is significantly higher than downtown and areas with fewer trees. Trees may also reduce heat stress by shading individuals from incoming radiation, though this is not considered in this study. Greater amounts of impervious surfaces correspond with reduced evapotranspiration and greater runoff, in terms of overall mass balance, leading to a higher temperature, but lower relative humidity. Heat index and relative humidity were found to significantly vary between locations with different tree cover and neighborhood characteristics for the full study time period as well as for the top 10% of heat index days. This work demonstrates the need for high-resolution climate data and the use of additional measures beyond temperature to understand urban neighborhood exposure to extreme heat, and expresses the importance of considering vulnerability differences among residents when analyzing neighborhood-scale impacts. PMID:26761021
Hass, Alisa L; Ellis, Kelsey N; Reyes Mason, Lisa; Hathaway, Jon M; Howe, David A
2016-01-11
Daily weather conditions for an entire city are usually represented by a single weather station, often located at a nearby airport. This resolution of atmospheric data fails to recognize the microscale climatic variability associated with land use decisions across and within urban neighborhoods. This study uses heat index, a measure of the combined effects of temperature and humidity, to assess the variability of heat exposure from ten weather stations across four urban neighborhoods and two control locations (downtown and in a nearby nature center) in Knoxville, Tennessee, USA. Results suggest that trees may negate a portion of excess urban heat, but are also associated with greater humidity. As a result, the heat index of locations with more trees is significantly higher than downtown and areas with fewer trees. Trees may also reduce heat stress by shading individuals from incoming radiation, though this is not considered in this study. Greater amounts of impervious surfaces correspond with reduced evapotranspiration and greater runoff, in terms of overall mass balance, leading to a higher temperature, but lower relative humidity. Heat index and relative humidity were found to significantly vary between locations with different tree cover and neighborhood characteristics for the full study time period as well as for the top 10% of heat index days. This work demonstrates the need for high-resolution climate data and the use of additional measures beyond temperature to understand urban neighborhood exposure to extreme heat, and expresses the importance of considering vulnerability differences among residents when analyzing neighborhood-scale impacts.
Observed correlations between aerosol and cloud properties in an Indian Ocean trade cumulus regime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pistone, Kristina; Praveen, Puppala S.; Thomas, Rick M.
There are many contributing factors which determine the micro- and macrophysical properties of clouds, including atmospheric vertical structure, dominant meteorological conditions, and aerosol concentration, all of which may be coupled to one another. In the quest to determine aerosol effects on clouds, these potential relationships must be understood. Here we describe several observed correlations between aerosol conditions and cloud and atmospheric properties in the Indian Ocean winter monsoon season.In the CARDEX (Cloud, Aerosol, Radiative forcing, Dynamics EXperiment) field campaign conducted in February and March 2012 in the northern Indian Ocean, continuous measurements were made of atmospheric precipitable water vapor (PWV)more » and the liquid water path (LWP) of trade cumulus clouds, concurrent with measurements of water vapor flux, cloud and aerosol vertical profiles, meteorological data, and surface and total-column aerosol from instrumentation at a ground observatory and on small unmanned aircraft. We present observations which indicate a positive correlation between aerosol and cloud LWP only when considering cases with low atmospheric water vapor (PWV < 40 kg m –2), a criterion which acts to filter the data to control for the natural meteorological variability in the region.We then use the aircraft and ground-based measurements to explore possible mechanisms behind this observed aerosol–LWP correlation. The increase in cloud liquid water is found to coincide with a lowering of the cloud base, which is itself attributable to increased boundary layer humidity in polluted conditions. High pollution is found to correlate with both higher temperatures and higher humidity measured throughout the boundary layer. A large-scale analysis, using satellite observations and meteorological reanalysis, corroborates these covariations: high-pollution cases are shown to originate as a highly polluted boundary layer air mass approaching the observatory from a northwesterly direction. The source air mass exhibits both higher temperatures and higher humidity in the polluted cases. While the warmer temperatures may be attributable to aerosol absorption of solar radiation over the subcontinent, the factors responsible for the coincident high humidity are less evident: the high-aerosol conditions are observed to disperse with air mass evolution, along with a weakening of the high-temperature anomaly, while the high-humidity condition is observed to strengthen in magnitude as the polluted air mass moves over the ocean toward the site of the CARDEX observations. In conclusion, potential causal mechanisms of the observed correlations, including meteorological or aerosol-induced factors, are explored, though future research will be needed for a more complete and quantitative understanding of the aerosol–humidity relationship.« less
Observed correlations between aerosol and cloud properties in an Indian Ocean trade cumulus regime
NASA Astrophysics Data System (ADS)
Pistone, Kristina; Praveen, Puppala S.; Thomas, Rick M.; Ramanathan, Veerabhadran; Wilcox, Eric M.; Bender, Frida A.-M.
2016-04-01
There are many contributing factors which determine the micro- and macrophysical properties of clouds, including atmospheric vertical structure, dominant meteorological conditions, and aerosol concentration, all of which may be coupled to one another. In the quest to determine aerosol effects on clouds, these potential relationships must be understood. Here we describe several observed correlations between aerosol conditions and cloud and atmospheric properties in the Indian Ocean winter monsoon season.In the CARDEX (Cloud, Aerosol, Radiative forcing, Dynamics EXperiment) field campaign conducted in February and March 2012 in the northern Indian Ocean, continuous measurements were made of atmospheric precipitable water vapor (PWV) and the liquid water path (LWP) of trade cumulus clouds, concurrent with measurements of water vapor flux, cloud and aerosol vertical profiles, meteorological data, and surface and total-column aerosol from instrumentation at a ground observatory and on small unmanned aircraft. We present observations which indicate a positive correlation between aerosol and cloud LWP only when considering cases with low atmospheric water vapor (PWV < 40 kg m-2), a criterion which acts to filter the data to control for the natural meteorological variability in the region.We then use the aircraft and ground-based measurements to explore possible mechanisms behind this observed aerosol-LWP correlation. The increase in cloud liquid water is found to coincide with a lowering of the cloud base, which is itself attributable to increased boundary layer humidity in polluted conditions. High pollution is found to correlate with both higher temperatures and higher humidity measured throughout the boundary layer. A large-scale analysis, using satellite observations and meteorological reanalysis, corroborates these covariations: high-pollution cases are shown to originate as a highly polluted boundary layer air mass approaching the observatory from a northwesterly direction. The source air mass exhibits both higher temperatures and higher humidity in the polluted cases. While the warmer temperatures may be attributable to aerosol absorption of solar radiation over the subcontinent, the factors responsible for the coincident high humidity are less evident: the high-aerosol conditions are observed to disperse with air mass evolution, along with a weakening of the high-temperature anomaly, while the high-humidity condition is observed to strengthen in magnitude as the polluted air mass moves over the ocean toward the site of the CARDEX observations. Potential causal mechanisms of the observed correlations, including meteorological or aerosol-induced factors, are explored, though future research will be needed for a more complete and quantitative understanding of the aerosol-humidity relationship.
Observed correlations between aerosol and cloud properties in an Indian Ocean trade cumulus regime
Pistone, Kristina; Praveen, Puppala S.; Thomas, Rick M.; ...
2016-04-27
There are many contributing factors which determine the micro- and macrophysical properties of clouds, including atmospheric vertical structure, dominant meteorological conditions, and aerosol concentration, all of which may be coupled to one another. In the quest to determine aerosol effects on clouds, these potential relationships must be understood. Here we describe several observed correlations between aerosol conditions and cloud and atmospheric properties in the Indian Ocean winter monsoon season.In the CARDEX (Cloud, Aerosol, Radiative forcing, Dynamics EXperiment) field campaign conducted in February and March 2012 in the northern Indian Ocean, continuous measurements were made of atmospheric precipitable water vapor (PWV)more » and the liquid water path (LWP) of trade cumulus clouds, concurrent with measurements of water vapor flux, cloud and aerosol vertical profiles, meteorological data, and surface and total-column aerosol from instrumentation at a ground observatory and on small unmanned aircraft. We present observations which indicate a positive correlation between aerosol and cloud LWP only when considering cases with low atmospheric water vapor (PWV < 40 kg m –2), a criterion which acts to filter the data to control for the natural meteorological variability in the region.We then use the aircraft and ground-based measurements to explore possible mechanisms behind this observed aerosol–LWP correlation. The increase in cloud liquid water is found to coincide with a lowering of the cloud base, which is itself attributable to increased boundary layer humidity in polluted conditions. High pollution is found to correlate with both higher temperatures and higher humidity measured throughout the boundary layer. A large-scale analysis, using satellite observations and meteorological reanalysis, corroborates these covariations: high-pollution cases are shown to originate as a highly polluted boundary layer air mass approaching the observatory from a northwesterly direction. The source air mass exhibits both higher temperatures and higher humidity in the polluted cases. While the warmer temperatures may be attributable to aerosol absorption of solar radiation over the subcontinent, the factors responsible for the coincident high humidity are less evident: the high-aerosol conditions are observed to disperse with air mass evolution, along with a weakening of the high-temperature anomaly, while the high-humidity condition is observed to strengthen in magnitude as the polluted air mass moves over the ocean toward the site of the CARDEX observations. In conclusion, potential causal mechanisms of the observed correlations, including meteorological or aerosol-induced factors, are explored, though future research will be needed for a more complete and quantitative understanding of the aerosol–humidity relationship.« less
Black carbon solar absorption suppresses turbulence in the atmospheric boundary layer.
Wilcox, Eric M; Thomas, Rick M; Praveen, Puppala S; Pistone, Kristina; Bender, Frida A-M; Ramanathan, Veerabhadran
2016-10-18
The introduction of cloud condensation nuclei and radiative heating by sunlight-absorbing aerosols can modify the thickness and coverage of low clouds, yielding significant radiative forcing of climate. The magnitude and sign of changes in cloud coverage and depth in response to changing aerosols are impacted by turbulent dynamics of the cloudy atmosphere, but integrated measurements of aerosol solar absorption and turbulent fluxes have not been reported thus far. Here we report such integrated measurements made from unmanned aerial vehicles (UAVs) during the CARDEX (Cloud Aerosol Radiative Forcing and Dynamics Experiment) investigation conducted over the northern Indian Ocean. The UAV and surface data reveal a reduction in turbulent kinetic energy in the surface mixed layer at the base of the atmosphere concurrent with an increase in absorbing black carbon aerosols. Polluted conditions coincide with a warmer and shallower surface mixed layer because of aerosol radiative heating and reduced turbulence. The polluted surface mixed layer was also observed to be more humid with higher relative humidity. Greater humidity enhances cloud development, as evidenced by polluted clouds that penetrate higher above the top of the surface mixed layer. Reduced entrainment of dry air into the surface layer from above the inversion capping the surface mixed layer, due to weaker turbulence, may contribute to higher relative humidity in the surface layer during polluted conditions. Measurements of turbulence are important for studies of aerosol effects on clouds. Moreover, reduced turbulence can exacerbate both the human health impacts of high concentrations of fine particles and conditions favorable for low-visibility fog events.
Black carbon solar absorption suppresses turbulence in the atmospheric boundary layer
Wilcox, Eric M.; Thomas, Rick M.; Praveen, Puppala S.; Pistone, Kristina; Bender, Frida A.-M.; Ramanathan, Veerabhadran
2016-01-01
The introduction of cloud condensation nuclei and radiative heating by sunlight-absorbing aerosols can modify the thickness and coverage of low clouds, yielding significant radiative forcing of climate. The magnitude and sign of changes in cloud coverage and depth in response to changing aerosols are impacted by turbulent dynamics of the cloudy atmosphere, but integrated measurements of aerosol solar absorption and turbulent fluxes have not been reported thus far. Here we report such integrated measurements made from unmanned aerial vehicles (UAVs) during the CARDEX (Cloud Aerosol Radiative Forcing and Dynamics Experiment) investigation conducted over the northern Indian Ocean. The UAV and surface data reveal a reduction in turbulent kinetic energy in the surface mixed layer at the base of the atmosphere concurrent with an increase in absorbing black carbon aerosols. Polluted conditions coincide with a warmer and shallower surface mixed layer because of aerosol radiative heating and reduced turbulence. The polluted surface mixed layer was also observed to be more humid with higher relative humidity. Greater humidity enhances cloud development, as evidenced by polluted clouds that penetrate higher above the top of the surface mixed layer. Reduced entrainment of dry air into the surface layer from above the inversion capping the surface mixed layer, due to weaker turbulence, may contribute to higher relative humidity in the surface layer during polluted conditions. Measurements of turbulence are important for studies of aerosol effects on clouds. Moreover, reduced turbulence can exacerbate both the human health impacts of high concentrations of fine particles and conditions favorable for low-visibility fog events. PMID:27702889
Cheng, Yu-Hsiang; Huang, Cheng-Hsiung; Huang, Hsiao-Lin; Tsai, Chuen-Jinn
2010-12-15
Research regarding the magnitude of ultrafine particle levels at highway toll stations is limited. This study measured ambient concentrations of ultrafine particles at a highway toll station from October 30 to November 1 and November 5 to November 6, 2008. A scanning mobility particle sizer was used to measure ultrafine particle concentrations at a ticket/cash tollbooth. Levels of hourly average ultrafine particles at the tollbooth were about 3-6 times higher than those in urban backgrounds, indicating that a considerable amount of ultrafine particles are exhausted from passing vehicles. A bi-modal size distribution pattern with a dominant mode at about <6 nm and a minor mode at about 40 nm was observed at the tollbooth. The high amounts of nanoparticles in this study can be attributed to gas-to-particle reactions in fresh fumes emitted directly from vehicles. The influences of traffic volume, wind speed, and relative humidity on ultrafine particle concentrations were also determined. High ambient concentrations of ultrafine particles existed under low wind speed, low relative humidity, and high traffic volume. Although different factors account for high ambient concentrations of ultrafine particles at the tollbooth, measurements indicate that toll collectors who work close to traffic emission sources have a high exposure risk. Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudd, A.
This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. In older homes in warm-humid climates, cooling loads are typically high and cooling equipment runs a lot to cool the air. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisturemore » being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and some winter days. In warm-humid climates, those long off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and avoids adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudd, Armin
This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. Cooling loads are typically high and cooling equipment runs a lot to cool the air in older homes in warm-humid climates. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisturemore » being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and winter days. In warm-humid climates, those long-off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.« less
Su, Wen-jin; Wang, Li-min; Weng, Shao-fan; Wang, Hai-jiao; Du, Li-li; Liu, Yue-wei; Yang, Lei; Chen, Wei-hong
2008-04-01
To assess the effects of the alteration of humidity and (or) temperature on weight of filters without and with ambient particulate matter in a balance room. The mass of blank dust sampling filters were weighed under (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively, with the humidity varying from 35% relative humidity (RH) to 100% RH in a balance room. Then the blank filters were divided into two groups and were used to sample total dust and respirable dust. After sampling, the loaded filters were re-weighed under above conditions and the mass difference before and after the sampling were compared and analyzed. The vibration of the average mass of filters varied from 0.10 to 0.13 mg and from 0.06 to 0.09 mg under the temperatures of (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively; When both the temperature and humidity changed, it varied from 0.12 to 0.16 mg. The deviation of average mass difference ranged from 0.07 to 0.10 mg and from 0.04 to 0.08 mg under the two temperatures mentioned above; When both the temperature and humidity changed, it varied from 0.09 to 0.14 mg. The average mass of blank filters and loaded filters were all positively correlated with the change of humidity (P < 0.01). No effects of humidity on the average mass difference of the loaded filters were observed. The average mass differences of loaded filters and blank filters under (18 +/- 1) degrees C were significantly higher than that under (28 +/- 1) degrees C (P < 0.01) when humidity was not changed. The alteration of humidity and (or) temperature in a balance room attributes to the deviation of the measurement of the mass of filters and thus affects the gravimetric measurements of ambient particulate matter.
Stomata of the CAM plant Tillandsia recurvata respond directly to humidity.
Lange, O L; Medina, E
1979-01-01
Under controlled conditions, CO 2 exchange of Tillandsia recurvata showed all characteristics of CAM. During the phase of nocturnal CO 2 fixation stomata of the plant responded sensitively to changes in ambient air humidity. Dry air resulted in an increase, moist air in a decrease of diffusion resistance. The evaporative demand of the air affected the level of stomatal resistance during the entire night period. Due to stomatal closure, the total nocturnal water loss of T. recurvata was less at low than at high humidity. It is concluded that stomata respond directly to humidity and not via bulk tissue water conditions of the leaves. Such control of transpiration may optimize water use efficiency for this almost rootless, extreme epiphyte.
Potato growth in response to relative humidity
NASA Technical Reports Server (NTRS)
Wheeler, R. M.; Tibbitts, T. W.; Fitzpatrick, A. H.
1989-01-01
Potato plants (Solanum tuberosum L. cvs. Russet Burbank, Norland, and Denali) were grown for 56 days in controlled-environment rooms under continuous light at 20C and 50% or 85% RH. No significant differences in total plant dry weight were measured between the humidity treatments, but plants grown under 85% RH produced higher tuber yields. Leaf areas were greater under 50% RH and leaves tended to be larger and darker green than at 85% RH.
Fujita, S; Obara, T; Tanaka, I; Yamauchi, C
1981-01-01
The relation of the rate of circulating air change to room temperature and relative humidity in animal quarters with a central air-conditioning system during heating and cooling seasons was investigated, with the results as follows: During the period of heating, the ambient temperature generally rose with a fall of relative humidity as the number of conditioned air changes per hour was increased. Vertical differences in temperature and humidity between levels of 0.5 and 1.5 m above the floor also diminished with increasing air change rate. This tendency was more conspicuous in small animals rooms with outer walls facing north and west. With increasing rate of air changes, the room temperature was prone to decline and the relative humidity to rise during the period of cooling. There were less vertical differences in temperature and humidity during this period. The velocity of air circulation within the animal quarters and its variations tended to increase progressively with increasing rate of ventilation, though the changes were modest.
TiO2-TiO2 composite resistive humidity sensor: ethanol crosssensitivity
NASA Astrophysics Data System (ADS)
Ghalamboran, Milad; Saedi, Yasin
2016-03-01
The fabrication method and characterization results of a TiO2-TiO2 composite bead used for humidity sensing along with its negative cross-sensitivity to ethanol vapor are reported. The bead shaped resistive sample sensors are fabricated by the drop-casting of a TiO2 slurry on two Pt wire segments. The dried bead is pre-fired at 750°C and subsequently impregnated with a Ti-based sol. The sample is ready for characterization after a thermal annealing at 600°C in air. Structurally, the bead is a composite of the micron-sized TiO2 crystallites embedded in a matrix of nanometric TiO2 particle aggregates. The performance of the beads as resistive humidity sensors is recorded at room temperature in standard humidity level chambers. Results evince the wide dynamic range of the sensors fabricated in the low relative humidity range. While the sensor conductance is not sensitive to ethanol vapor in dry air, in humid air, sensor's responses are negatively affected by the contaminant.
[Worker heat disorders at the Fukushima Daiichi nuclear power plant].
Tsuji, Masayoshi; Kakamu, Takeyasu; Hayakawa, Takehito; Kumagai, Tomohiro; Hidaka, Tomoo; Kanda, Hideyuki; Fukushima, Tetsuhito
2013-01-01
Ever since the Fukushima Daiichi nuclear power plant (NPP) accident, every day about 3,000 workers have been working to repair the situation. The frequent occurrence of heat disorders has been a concern for the workers wearing protective clothing with poor ventilation. We have been analyzing the heat disorder problem since the accident in order to come up with a solution to prevent future heat disorder incidents among Fukushima Daiichi NPP accident clean-up workers. From March 22 to September 16, 2011, the Fukushima Labor Bureau assessed 43 cases of nuclear power plant workers with heat disorders. Age of subject, month and time of occurrence, temperature, and humidity were examined for each case, as well as the severity of heat disorders. The grade of severity was divided into Grade I and Grade II or higher. Then, age, temperature, and humidity were analyzed using the Mann-Whitney Utest, and age, temperature, humidity, and presence or absence of a cool-vest were analyzed using the χ(2) test and logistic regression analysis. SPSS version 17.0 statistical software was used with a level of significance of p< 0.05. Heat disorders occurred most frequently in subjects in their 40s (30.2%), followed by those in their 30s (25.6%), mostly in July (46.5%) between 7 am and 12 pm (69.8%). Heat disorders occurred most frequently in environments with temperatures more than 25°C (76.7%) and humidity of 70-80% (39.5%). Heat disorders of Grade II or higher occurred in 10 cases, 5 of which were in June. According to statistical analysis, there were no significant differences in difference of severity for all factors. Heat disorders usually occur in workers aged 45-60; however, cases of heat disorders at the Fukushima Daiichi NPP occurred in clean-up workers at the relatively younger ages of 30-40, suggesting the need for heat disorder prevention measures for these younger workers. Heat disorder cases primarily occurred in the morning, necessitating preventive measures for the early hours of the day. In addition, because heat disorders of Grade II or higher occurred in June in 5 of 10 cases, we believe heat disorder precautions should be implemented from June. The lack of significant difference in severity difference may be attributable to the small number of cases or other factors. We think Fukushima Daiichi NPP accident clean-up workers need heat disorder prevention measures for their safety, based on the results of this study.
Comparison of land-surface humidity between observations and CMIP5 models
NASA Astrophysics Data System (ADS)
Dunn, Robert; Willett, Kate; Ciavarella, Andrew; Stott, Peter; Jones, Gareth
2017-04-01
We compare the latest observational land-surface humidity dataset, HadISDH, with the CMIP5 model archive spatially and temporally over the period 1973-2015. None of the CMIP5 models or experiments capture the observed temporal behaviour of the globally averaged relative or specific humidity over the entire study period. When using an atmosphere-only model, driven by observed sea-surface temperatures and radiative forcing changes, the behaviour of regional average temperature and specific humidity are better captured, but there is little improvement in the relative humidity. Comparing the observed and historical model climatologies show that the models are generally cooler everywhere, are drier and less saturated in the tropics and extra tropics, and have comparable moisture levels but are more saturated in the high latitudes. The spatial pattern of linear trends are relatively similar between the models and HadISDH for temperature and specific humidity, but there are large differences for relative humidity, with less moistening shown in the models over the Tropics, and very little at high atitudes. The observed temporal behaviour appears to be a robust climate feature rather than observational error. It has been previously documented and is theoretically consistent with faster warming rates over land compared to oceans. Thus, the poor replication in the models, especially in the atmosphere only model, leads to questions over future projections of impacts related to changes in surface relative humidity.
Gerba, Charles P.; Tamimi, Akrum H.; Kitajima, Masaaki; Maxwell, Sheri L.; Rose, Joan B.
2013-01-01
Fomites can serve as routes of transmission for both enteric and respiratory pathogens. The present study examined the effect of low and high relative humidity on fomite-to-finger transfer efficiency of five model organisms from several common inanimate surfaces (fomites). Nine fomites representing porous and nonporous surfaces of different compositions were studied. Escherichia coli, Staphylococcus aureus, Bacillus thuringiensis, MS2 coliphage, and poliovirus 1 were placed on fomites in 10-μl drops and allowed to dry for 30 min under low (15% to 32%) or high (40% to 65%) relative humidity. Fomite-to-finger transfers were performed using 1.0 kg/cm2 of pressure for 10 s. Transfer efficiencies were greater under high relative humidity for both porous and nonporous surfaces. Most organisms on average had greater transfer efficiencies under high relative humidity than under low relative humidity. Nonporous surfaces had a greater transfer efficiency (up to 57%) than porous surfaces (<6.8%) under low relative humidity, as well as under high relative humidity (nonporous, up to 79.5%; porous, <13.4%). Transfer efficiency also varied with fomite material and organism type. The data generated can be used in quantitative microbial risk assessment models to assess the risk of infection from fomite-transmitted human pathogens and the relative levels of exposure to different types of fomites and microorganisms. PMID:23851098
Post-discharge gas composition of a large-gap DBD in humid air by UV-Vis absorption spectroscopy
NASA Astrophysics Data System (ADS)
Moiseev, T.; Misra, N. N.; Patil, S.; Cullen, P. J.; Bourke, P.; Keener, K. M.; Mosnier, J. P.
2014-12-01
Large gap dielectric barrier discharges (DBD) provide non-thermal, non-equilibrium plasmas that can generate specific gas chemistry with enhanced bactericidal effects when working in humid air. The present study investigates the post-discharge gas composition of such plasmas operated in humid air using UV-Vis (200-800 nm) absorption spectroscopy. Absorbance spectra have been de-convoluted using direct deconvolution and iterative methods and results are correlated to the DBD electrical parameters. The high-voltage (56 and 70 kV rms) DBD plasma generated at 50 Hz frequency in a closed container over a 20 mm gap in air with relative humidity (RH) of 5-70% has been characterized by I-V and capacitive methods. The post-discharge gas composition at each RH is assessed by UV-Vis absorption spectroscopy for plasma exposure times of 15-120 s. The concentration of ozone and nitrogen oxides (O3, NO2, NO3, N2O4) increases with plasma exposure time but a strong decrease in [O3] levels is obtained with increase in RH. The decrease in [O3] and an abundance of nitrogen oxides is ascribed to high specific power densities in the closed container and to increasing RH levels. The absorbance residual following deconvolution shows a strong band at 230-270 nm consistent with the presence of pernitric acid (HNO4) and other HNOx (x = 1, 3) species. Humid air large gap DBD plasmas in closed containers generate along with O3, high levels of nitrogen oxides and HNOx (x = 1, 4) acids leading to increased bactericidal rates.
Drying characteristics and modeling of yam slices under different relative humidity conditions
USDA-ARS?s Scientific Manuscript database
The drying characteristics of yam slices under different 23 constant relative humidity (RH) and step-down RH levels were studied. A mass transfer model was developed based on Bi-Di correlations containing a drying coefficient and a lag factor to describe the drying process. It was validated using ex...
Equilibrium Moisture Content of Common Fine Fuels in Southeastern Forests
W.H. Blackmarr
1971-01-01
Nine different kinds of forest litter found in ground fuel complexes of southeastern forests were subjected to step-wise changes in relative humidity to determine their equilibrium moisture content (EMC) at different levels of relative humidity. The adsorption and desorption EMC curves for these fuels exhibited the typical hysteresis loop...
Bannov, Alexander G; Prášek, Jan; Jašek, Ondřej; Zajíčková, Lenka
2017-02-09
Graphite oxide has been investigated as a possible room-temperature chemiresistive sensor of ammonia in a gas phase. Graphite oxide was synthesized from high purity graphite using the modified Hummers method. The graphite oxide sample was investigated using scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, thermogravimetry and differential scanning calorimetry. Sensing properties were tested in a wide range of ammonia concentrations in air (10-1000 ppm) and under different relative humidity levels (3%-65%). It was concluded that the graphite oxide-based sensor possessed a good response to NH₃ in dry synthetic air (ΔR/R₀ ranged from 2.5% to 7.4% for concentrations of 100-500 ppm and 3% relative humidity) with negligible cross-sensitivity towards H₂ and CH₄. It was determined that the sensor recovery rate was improved with ammonia concentration growth. Increasing the ambient relative humidity led to an increase of the sensor response. The highest response of 22.2% for 100 ppm of ammonia was achieved at a 65% relative humidity level.
Okubo, Torahiko; Osaki, Takako; Nozaki, Eriko; Uemura, Akira; Sakai, Kouhei; Matushita, Mizue; Matsuo, Junji; Nakamura, Shinji; Kamiya, Shigeru; Yamaguchi, Hiroyuki
2017-01-01
Although human occupancy is a source of airborne bacteria, the role of walkers on bacterial communities in built environments is poorly understood. Therefore, we visualized the impact of walker occupancy combined with other factors (temperature, humidity, atmospheric pressure, dust particles) on airborne bacterial features in the Sapporo underground pedestrian space in Sapporo, Japan. Air samples (n = 18; 4,800L/each sample) were collected at 8:00 h to 20:00 h on 3 days (regular sampling) and at early morning / late night (5:50 h to 7:50 h / 22:15 h to 24:45 h) on a day (baseline sampling), and the number of CFUs (colony forming units) OTUs (operational taxonomic units) and other factors were determined. The results revealed that temperature, humidity, and atmospheric pressure changed with weather. The number of walkers increased greatly in the morning and evening on each regular sampling day, although total walker numbers did not differ significantly among regular sampling days. A slight increase in small dust particles (0.3-0.5μm) was observed on the days with higher temperature regardless of regular or baseline sampling. At the period on regular sampling, CFU levels varied irregularly among days, and the OTUs of 22-phylum types were observed, with the majority being from Firmicutes or Proteobacteria (γ-), including Staphylococcus sp. derived from human individuals. The data obtained from regular samplings reveled that although no direct interaction of walker occupancy and airborne CFU and OTU features was observed upon Pearson's correlation analysis, cluster analysis indicated an obvious lineage consisting of walker occupancy, CFU numbers, OTU types, small dust particles, and seasonal factors (including temperature and humidity). Meanwhile, at the period on baseline sampling both walker and CFU numbers were similarly minimal. Taken together, the results revealed a positive correlation of walker occupancy with airborne bacteria that increased with increases in temperature and humidity in the presence of airborne small particles. Moreover, the results indicated that small dust particles at high temperature and humidity may be a crucial factor responsible for stabilizing the bacteria released from walkers in built environments. The findings presented herein advance our knowledge and understanding of the relationship between humans and bacterial communities in built environments, and will help improve public health in urban communities.
Okubo, Torahiko; Osaki, Takako; Nozaki, Eriko; Uemura, Akira; Sakai, Kouhei; Matushita, Mizue; Matsuo, Junji; Nakamura, Shinji; Kamiya, Shigeru
2017-01-01
Although human occupancy is a source of airborne bacteria, the role of walkers on bacterial communities in built environments is poorly understood. Therefore, we visualized the impact of walker occupancy combined with other factors (temperature, humidity, atmospheric pressure, dust particles) on airborne bacterial features in the Sapporo underground pedestrian space in Sapporo, Japan. Air samples (n = 18; 4,800L/each sample) were collected at 8:00 h to 20:00 h on 3 days (regular sampling) and at early morning / late night (5:50 h to 7:50 h / 22:15 h to 24:45 h) on a day (baseline sampling), and the number of CFUs (colony forming units) OTUs (operational taxonomic units) and other factors were determined. The results revealed that temperature, humidity, and atmospheric pressure changed with weather. The number of walkers increased greatly in the morning and evening on each regular sampling day, although total walker numbers did not differ significantly among regular sampling days. A slight increase in small dust particles (0.3–0.5μm) was observed on the days with higher temperature regardless of regular or baseline sampling. At the period on regular sampling, CFU levels varied irregularly among days, and the OTUs of 22-phylum types were observed, with the majority being from Firmicutes or Proteobacteria (γ-), including Staphylococcus sp. derived from human individuals. The data obtained from regular samplings reveled that although no direct interaction of walker occupancy and airborne CFU and OTU features was observed upon Pearson's correlation analysis, cluster analysis indicated an obvious lineage consisting of walker occupancy, CFU numbers, OTU types, small dust particles, and seasonal factors (including temperature and humidity). Meanwhile, at the period on baseline sampling both walker and CFU numbers were similarly minimal. Taken together, the results revealed a positive correlation of walker occupancy with airborne bacteria that increased with increases in temperature and humidity in the presence of airborne small particles. Moreover, the results indicated that small dust particles at high temperature and humidity may be a crucial factor responsible for stabilizing the bacteria released from walkers in built environments. The findings presented herein advance our knowledge and understanding of the relationship between humans and bacterial communities in built environments, and will help improve public health in urban communities. PMID:28922412
Soil sorption of organic vapors and effects of humidity on sorptive mechanism and capacity
Chiou, C.T.; Shoup, T.D.
1985-01-01
Vapor sorption isotherms on dry Woodburn soil at 20-30??C were determined for benzene, chlorobenzene, p-dichlorobenzene, m-dichlorobenzene, 1,2,4-trichlorobenzene, and water as single vapors and for benzene, m-dichlorobenzene, and 1,2,4-trichlorobenzene as functions of relative humidity (RH). Isotherms for all compounds on dry soil samples are distinctively nonlinear, with water showing the greatest capacity. Water vapor sharply reduced the sorption capacities of organic compounds with the dry soil; on water-saturated soil, the reduction was about 2 orders of magnitude. The markedly higher sorption of organic vapors at subsaturation humidities is attributed to adsorption on the mineral matter, which predominates over the simultaneous uptake by partition into the organic matter. At about 90% RH, the sorption capacities of organic compounds become comparable to those in aqueous systems. The effect of humidity is attributed to adsorptive displacement by water of organics adsorbed on the mineral matter. A small residual uptake is attributed to the partition into the soil-organic phase that has been postulated in aqueous systems. The results are essentially in keeping with the model that was previously proposed for sorption on the soil from water and from organic solvents.Vapor sorption isotherms on dry Woodburn soil at 20-30 degree C were determined for benzene, chlorobenzene, p-dichlorobenzene, m-dichlorobenzene, 1,2,4-trichlorobenzene, and water as single vapors and for benzene, m-dichlorobenzene, and 1,2,4-trichlorobenzene as functions of relative humidity (RH). Isotherms for all compounds on dry soil samples are distinctively nonlinear, with water showing the greatest capacity. Water vapor sharply reduced the sorption capacities of organic compounds with the dry soil; on water-saturated soil, the reduction was about 2 orders of magnitude. The markedly higher sorption of organic vapors at subsaturation humidities is attributed to adsorption on the mineral matter. The results are essentially in keeping with the model that was previously proposed for sorption on the soil from water and from organic solvents.
Li, Ya-jie; Zhang, Li-ying; Luo, Bing-de; Li, Yi-lei; Lin, Ni
2004-03-01
To observe the changes of heart rate (HR) and mean arterial pressure MAP after immediate cooling therapy (ICT) in rats with superficial second-degree scald burn in hot and humid environment, and assess the effect of the cooling dressing materials. Twenty-four Wistar rats were randomized equally into 4 groups including normal temperature control (NTC) group, normal temperature cooling therapy (NCT) group, hot and humid control (HHC) group and hot and humid cooling therapy (HCT) group. Different interventions were applied as indicated in the rats with superficial second-degree scald burn, with the dry bulb temperature Tdb at 26.33+/-1.29 degrees celsius; and relative humidity (rh) of 71.05%+/-4.57% for two normal temperature groups, and Tdb at 35.33+/-0.35 degrees Celsius; and rh of 70.81%+/-1.38% for the two hot and humid groups. The exposure time was 120 min in NCT and HCT groups, and the HR and MAP were measured every 20 min. MAP is not influenced by environmental temperature and the cooling therapy (P>0.05), whereas HR was higher in HHC than in NTC group and also in HCT than in NCT group (P=0.003), lower in HCT and NCT groups than in HHC and NTC groups (P=0.002), respectively. HR did not undergo any significant changes during the observation in the 4 groups (P>0.05). HR was higher in HHC and HCT than in NTC and NCT groups at 65, 85, 105 and 125 min after the burns, but compared with the two control groups, cooling therapy decreased HR at 5, 25, 45 and 85 min. Cooling therapy does not affect MAP but efficiently decreases HR, which may prevent further heat injury.
Audenaert, J; Vangansbeke, D; Verhoeven, R; De Clercq, P; Tirry, L; Gobin, B
2014-01-01
Predatory mites like Phytoseiulus persimilis Athias-Henriot, Neoseiulus californicus McGregor and N. fallacis (Garman) (Acari: Phytoseiidae) are essential in sustainable control strategies of the two-spotted spider mite Tetranychus urticae Koch (Acari: Tetranychidae) in warm greenhouse cultures to complement imited available pesticides and to tackle emerging resistance. However, in response to high energy prices, greenhouse plant breeders have recently changed their greenhouse steering strategies, allowing more variation in temperature and humidity. The impact of these variations on biological control agents is poorly understood. Therefore, we constructed functional response models to demonstrate the impact of realistic climate variations on predation efficiency. First, two temperature regimes were compared at constant humidity (70%) and photoperiod (16L:8D): DIF0 (constant temperature) and DIF15 (variable temperature with day-night difference of 15°C). At mean temperatures of 25°C, DIF15 had a negative influence on the predation efficiency of P. persimilis and N. californicus, as compared to DIF0. At low mean temperatures of 15°C, however, DIF15 showed a higher predation efficiency for P. persimilis and N. californicus. For N. fallacis no difference was observed at both 15°C and 25°C. Secondly, two humidity regimes were compared, at a mean temperature of 25°C (DIFO) and constant photoperiod (16L:8D): RHCTE (constant 70% humidity) and RHALT (alternating 40% L:70%D humidity). For P. persimilis and N. fallacis RHCTE resulted in a higher predation efficiency than RHALT, for N. californicus this effect was opposite. This shows that N. californicus is more adapted to dry climates as compared to the other predatory mites. We conclude that variable greenhouse climates clearly affect predation efficiency of P. persimilis, N. californicus and N. fallacis. To obtain optimal control efficiency, the choice of predatory mites (including dose and application frequency) should be adapted to the actual greenhouse climate.
Wilkinson, Stacey Leonatti
2015-05-01
Proper care and husbandry are the most important factors in keeping captive reptiles healthy. Improper nutrition, supplementation, caging, lighting, substrate, temperature, and humidity can all lead to stress and development of disease. Presented here are current recommendations for keeping captive reptiles. Care has moved away from sterile, spartan enclosures to larger, more naturalistic habitats. These habitats provide more space and choices for the reptile, leading to higher activity levels, reduced stress, and more opportunities to exhibit natural behaviors. Reptiles benefit from enrichment and are amenable to training in order to reduce stress and allow easier handling and veterinary care. Copyright © 2015 Elsevier Inc. All rights reserved.
Iida, Ryosuke; Koketsu, Yuzo
2013-09-15
The objectives of this study were to determine the associations between climatic factors and production factors for returns to service of female pigs during summer and to quantify the associations between these factors and occurrences of returns to service. The factors that were assessed were as follows: maximum temperature (HT), relative humidity, age of gilts at first mating, parity, weaning-to-first-mating interval (WMI), and lactation length. The study analyzed records of 18,307 gilts in 99 herds and 78,135 parity records of 56,322 sows in 103 herds; all the females were first-serviced between June and September, 2007 to 2009. Average daily HT and relative humidity for 15 days post-service of a female were obtained from 21 local weather stations and coordinated with the performance data of the respective local herds. The returns to service were categorized into three groups: regular returns (RRs: 18-24 days), irregular returns (IRs: 25-38 days), and late returns to service (LRs: 39 days or later). Two-level mixed-effects models were applied to the data by using a herd at level 2 and an individual record at level 1. In mated gilts, the occurrences (%) of RRs, IRs, and LRs were 4.8%, 1.8%, and 5.3%, respectively. In mated sows, the respective occurrences were 3.3%, 1.8%, and 4.2%. Mean values (ranges) of HT and relative humidity were 28.4 °C (13.6 °C-39.8 °C) and 73.4% (35.0%-98.0%), respectively. In gilts, as HT increased from 25 °C to 30 °C, the occurrence of RR increased from 3.7% to 4.4% (P < 0.05). However, there was no association between the occurrence of RR and either relative humidity (P = 0.17) or age at first mating (P = 0.23). In addition, there were no associations between the occurrences of either gilt IR or LR and HT (P ≥ 0.05), relative humidity (P ≥ 0.46), or age at first mating (P ≥ 0.32). In sows, greater occurrences of RRs, IRs, and LRs were associated with higher HT, lower parity, and a WMI of 7 days or longer (P < 0.05), but they were not associated with relative humidity (P ≥ 0.62) or lactation length (P ≥ 0.13). The occurrence of RRs in sows of all WMI groups increased 1.22 (1.04(5)) times for each 5 °C increase in HT. For sows with WMI 0 to 6 days, each 5 °C rise in HT increased the occurrence of IRs and LRs by 1.36 (1.06(5)) and 1.27 (1.05(5)) times, respectively. However, there was no association between increased HT and occurrences of IRs or LRs for sows with WMI 7 days or longer (P ≥ 0.38). Therefore, in order to prevent returns to service, it is recommended that producers apply cooling management for females during the post-service periods in summer. Copyright © 2013 Elsevier Inc. All rights reserved.
Nelson, J. Stuart; Anvari, Bahman; Tanenbaum, B. Samuel; Milner, Thomas E.
1999-01-01
Cryogen spray cooling of skin surface with millisecond cryogen spurts is an effective method for establishing a controlled temperature distribution in tissue and protecting the epidermis from nonspecific thermal injury during laser mediated dermatological procedures. Control of humidity level, spraying distance and cryogen boiling point is material to the resulting surface temperature. Decreasing the ambient humidity level results in less ice formation on the skin surface without altering the surface temperature during the cryogen spurt. For a particular delivery nozzle, increasing the spraying distance to 85 millimeters lowers the surface temperature. The methodology comprises establishing a controlled humidity level in the theater of operation of the irradiation site of the biological tissues before and/or during the cryogenic spray cooling of the biological tissue. At cold temperatures calibration was achieved by mounting a thermistor on a thermoelectric cooler. The thermal electric cooler was cooled from from 20.degree. C. to about -20.degree. C. while measuring its infrared emission.
Optical dynamic range maximization for humidity sensing by controlling growth of zinc oxide nanorods
NASA Astrophysics Data System (ADS)
Yusof, Haziezol Helmi Mohd; Harun, Sulaiman Wadi; Dimyati, Kaharudin; Bora, Tanujjal; Mohammed, Waleed S.; Dutta, Joydeep
2018-07-01
An experimental study of the dynamic range maximization with Zinc Oxide (ZnO) nanorods coated glass substrates for humidity and vapor sensing is reported. Growth time of the nanorods and the length of the coated segments were controlled to study the differences between a reference environmental condition (normal humidity or dry condition) and water vapor concentrations. In order to achieve long dynamic range of detection with respect to nanorods coverage, several substrates with triangular patterns of ZnO nanostructures were fabricated by selective hydrothermal growth over different durations of time (5 h, 10 h and 15 h). It was found that maximum dynamic range for the humidity sensing occurs for the combination parameters of normalized length (Z) of 0.23 and normalized scattering coefficient (ζ) of 0.3. A reduction in transmittance by 38% at humidity levels of 80% with reference point as 50% humidity was observed. The results could be correlated to a first order approximation model that assumes uniform growth and the optimum operating conditions for humidity sensing device. This study provides an option to correlate ZnO growth conditions for different vapor sensing applications which can set a platform for compact sensors where modulation of light intensity is followed.
Weather, season, and daily stroke admissions in Hong Kong
NASA Astrophysics Data System (ADS)
Goggins, William B.; Woo, Jean; Ho, Suzanne; Chan, Emily Y. Y.; Chau, P. H.
2012-09-01
Previous studies examining daily temperature and stroke incidence have given conflicting results. We undertook this retrospective study of all stroke admissions in those aged 35 years old and above to Hong Kong public hospitals from 1999 through 2006 in order to better understand the effects of meteorological conditions on stroke risk in a subtropical setting. We used Poisson Generalized Additive Models with daily hemorrhagic (HS) and ischemic stroke (IS) counts separately as outcomes, and daily mean temperature, humidity, solar radiation, rainfall, air pressure, pollutants, flu consultation rates, day of week, holidays, time trend and seasonality as predictors. Lagged effects of temperature, humidity and pollutants were also considered. A total of 23,457 HS and 107,505 IS admissions were analyzed. Mean daily temperature had a strong, consistent, negative linear association with HS admissions over the range (8.2-31.8°C) observed. A 1°C lower average temperature over the same day and previous 4 days (lags 0-4) being associated with a 2.7% (95% CI: 2.0-3.4%, P < .0.0001) higher admission rate after controlling for other variables. This association was stronger among older subjects and females. Higher lag 0-4 average change in air pressure from previous day was modestly associated with higher HS risk. The association between IS and temperature was weaker and apparent only below 22°C, with a 1°C lower average temperature (lags 0-13) below this threshold being associated with a 1.6% (95% CI:1.0-2.2%, P < 0.0001) higher IS admission rate. Pollutant levels were not associated with HS or IS. Future studies should examine HS and IS risk separately.
NASA Astrophysics Data System (ADS)
Zhang, Dawei; Zhou, Feichi; Xiao, Kui; Cui, Tianyu; Qian, Hongchong; Li, Xiaogang
2015-07-01
Microbially induced corrosion (MIC) poses significant threats to reliability and safety of engineering materials and structures. While most MIC studies focus on prokaryotic bacteria such as sulfate-reducing bacteria, the influence of fungi on corrosion behaviors of metals has not been adequately reported. In this study, 304 stainless steel and titanium were exposed to two very common fungi, Paecilomyces variotii, Aspergillus niger and their mixtures under highly humid atmosphere. The initial corrosion behaviors within 28 days were studied via scanning Kelvin probe, which showed marked surface ennoblement and increasingly heterogeneous potential distribution upon prolonged fungus exposure. Using stereomicroscopy, fungus growth as well as corrosion morphology of 304 stainless steel and titanium were also evaluated after a long-term exposure for 60 days. The presence of fungi decreased the corrosion resistance for both 304 stainless steel and titanium. Titanium showed higher resistance to fungus growth and the induced corrosion. Exposure to the mixed strains resulted in the highest fungus growth rate but the mildest corrosion, possibly due to the decreased oxygen level by increased fungal activities.
[Adsorption characteristics of acetone and butanone onto honeycomb ZSM-5 molecular sieve].
Du, Juan; Luan, Zhi-Qiang; Xie, Qiang; Ye, Ping-Wei; Li, Kai; Wang, Xi-Qin
2013-12-01
Adsorption capacity of acetone and acetone-butanone mixture onto honeycomb ZSM-5 molecular sieve was measured in this paper, and the influences of relative humidity, initial adsorbate concentration and airflow velocity on the adsorption process were investigated. Besides, adsorption performance parameters were calculated by Wheeler's equation. The results showed that relative humidity had no obvious influence on the acetone adsorption performance, which suggests that this material has good hydrophobic ability; in the low concentration range, the dynamic saturated adsorption capacity of acetone increased with the increase of initial concentration, but in the occasion of high concentration of acetone gas (more than 9 mg x L(-1)), the dynamic saturated adsorption capacity maintained at a certain level and did not vary with the increase of initial concentration; the increase of air flow velocity resulted in significant increase of acetone adsorption rate constant, at the same time the critical layer thickness of the adsorbent bed also increased significantly. In the cases of acetone-butanone mixture, the adsorption capacity of butanone onto ZSM-5 was clearly higher than that of acetone.
Silva, Renato O DA; Souza, Everaldo B DE; Tavares, Alexandra L; Mota, José A; Ferreira, Douglas B S; Souza-Filho, Pedro W M; Rocha, Edson J P DA
2017-01-01
This study estimated the reference evapotranspiration rate (ETo) for the Itacaiúnas River Watershed (IRW), Eastern Amazonia, and measured the accuracy of eight empirical equations: Penman-Monteith (PM), Priestley-Taylor (PT), Hargreaves and Samani (HS), Camargo (CAM), Thornthwaite (TH), Hamon (HM), Kharrufa (KF) and Turc (TC) using monthly data from 1980 to 2013. In addition, it verifies the regional applicability to the IRW using a for the Marabá-PA station. The methods TC and PM (FAO56) presented the best results, which demonstrate that radiation and higher temperatures are the dominant drivers in the Evapotranspiration process, while relative humidity and wind speed have a much smaller impact. The temporal and spatial variability of ETo for IRW show has strong seasonality, increasing during the dry season and decreasing during the rainy season. The statistical analyses at 1% level of significance, indicates that there is no correlation of the residuals between the dry and rainy seasons, and test of the physical parameters such as mean temperature, solar radiation and relative air humidity explains the variations of ETo.
[Spatial analysis of Oncomelania snail information based on grid data-driven].
Liu, Gang; Huang, Qiong-Yao; Liu, Yun-Ziang; Wang, Jiang-Tao; Peng, Fei; Liu, Nian-Meng
2011-06-01
To explore the relationship between the Oncomelania snail situation and the distance to the water source, soil humidity, vegetation and water level in flood seasons in the islets of Changsha Section of the Xiang River. Combined with the NDVI and soil humidity of islets, the GIS spatial analysis based on grid data-driven was used to analyze the snail situation in Changsha Section of the Xiang River from 2005 to 2009. The relationship between the snail density and the water level in blood seasons was analyzed. In 2005, the snails in Zengpi Islet were mainly distributed at the range of 40-240 m far away from the nearest water source, and the number at the spots with a distance of 60 m was the largest. There was an obvious positive correlation between the snail density and water level in flood seasons. The ranges of the Normalized Difference Vegetation Index and soil humidity of Zengpi Islet in 2005 were 0-0.982 and 0-0.298, respectively and the main vegetation in Changsha Section of the Xiang River were weed and sedge. The map of snail situation by year was drawn according to the standard water level, which reflected the snail situation intuitionistically. By using spatial analysis based on grid data-driven, the situation of vegetation, soil humidity and snail accurately can be reflected, which can help us to understand the endemic situation timely. Even under the circumstance of human intervention, the water level in flood seasons is still an important factor influencing the change of snail situation.
Chikata, Yusuke; Imanaka, Hideaki; Onishi, Yoshiaki; Ueta, Masahiko; Nishimura, Masaji
2009-08-01
High-frequency oscillation ventilation (HFOV) is an accepted ventilatory mode for acute respiratory failure in neonates. As conventional mechanical ventilation, inspiratory gas humidification is essential. However, humidification during HFOV has not been clarified. In this bench study, we evaluated humidification during HFOV in the open circumstance of ICU. Our hypothesis is that humidification during HFOV is affected by circuit design and ventilatory settings. We connected a ventilator with HFOV mode to a neonatal lung model that was placed in an infant incubator set at 37 degrees C. We set a heated humidifier (Fisher & Paykel) to obtain 37 degrees C at the chamber outlet and 40 degrees C at the distal temperature probe. We measured absolute humidity and temperature at the Y-piece using a rapid-response hygrometer. We evaluated two types of ventilator circuit: a circuit with inner heating wire and another with embedded heating element. In addition, we evaluated three lengths of the inspiratory limb, three stroke volumes, three frequencies, and three mean airway pressures. The circuit with embedded heating element provided significantly higher absolute humidity and temperature than one with inner heating wire. As an extended tube lacking a heating wire was shorter, absolute humidity and temperature became higher. In the circuit with inner heating wire, absolute humidity and temperature increased as stroke volume increased. Humidification during HFOV is affected by circuit design and ventilatory settings.
NASA Astrophysics Data System (ADS)
Im, Eun-Soon; Kang, Suchul; Eltahir, Elfatih A. B.
2018-06-01
This study assesses the future changes in heat stress in response to different emission scenarios over the western Maritime Continent. To better resolve the region-specific changes and to enhance the performance in simulating extreme events, the MIT Regional Climate Model with a 12-km horizontal resolution is used for the dynamical downscaling of three carefully selected CMIP5 global projections forced by two Representative Concentration Pathway (RCP4.5 and RCP8.5) scenarios. Daily maximum wet-bulb temperature (TWmax), which includes the effect of humidity, is examined to describe heat stress as regulated by future changes in temperature and humidity. An ensemble of projections reveals robust pattern in which a large increase in temperature is accompanied by a reduction in relative humidity but a significant increase in wet-bulb temperature. This increase in TWmax is relatively smaller over flat and coastal regions than that over mountainous region. However, the flat and coastal regions characterized by warm and humid present-day climate will be at risk even under modest increase in TWmax. The regional extent exposed to higher TWmax and the number of days on which TWmax exceeds its threshold value are projected to be much higher in RCP8.5 scenario than those in RCP4.5 scenario, thus highlighting the importance of controlling greenhouse gas emissions to reduce the adverse impacts on human health and heat-related mortality.
NASA Astrophysics Data System (ADS)
Behnke, Ruben John
The objective of this dissertation was to show that there is now enough observed humidity data available so that estimates of humidity, along with their necessary assumptions, can be replaced by measured humidity data. The range of applications that depend on humidity data is huge, ranging from water use efficiency of plants and plant stress to human health and agricultural practices. Biases due to the use of estimated humidity can be expected to have short and long impacts, decreasing the accuracy and precision of these, and many other, applications. Data from local, regional, and national observation networks was gathered, and custom quality control routines were written to remove bad data points from over 45000 stations, leaving 12533 usable stations. While still not at the same number of observations as temperature or precipitation, this number is nearly ten times as high as two decades ago. The work I performed consists of three major components, corresponding to the three main chapters of this dissertation. In chapter one, I describe data sources and quality control methods, along with some basic statistics of humidity, describing which geographic variables often used to predict temperature and precipitation can be used to do the same for humidity. Chapter two defines specific diurnal patterns (or "types") of dew point across the United States, including their attributes, causes, and potential influences. Chapter three analyzes biases in evapotranspiration, heat indices, and relative humidity levels that are a direct result of using estimated humidity data. Chapter four discusses contributions this work makes to the scientific community, and potential further research to build on what is presented here. While it may seem that the science of humidity should be well beyond data gathering and bias analysis, the fact remains that humidity is still very commonly estimated through the use of minimum temperature, and diurnal changes in dew point are often ignored. My hope is that this work makes a dent in often deeply entrenched practices, leading others to make the effort to incorporate measured humidity data into their work and study.
Appearance and decay of strawberries, peaches, and lettuce treated with ozone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spalding, D.H.
1966-01-01
The ozone concentration is reduced greatly in a chamber when it is loaded with wet blotting paper or with produce. The Ozone concentration must be determined frequently to assure a fairly constant level. Ozone did not reduce botrytis rot of strawberries in tests at the temperatures of 55/sup 0/ to 60/sup 0/F, relative humidity of 95%, and ozone concentrations of 0.1 to 10 parts per million (ppM). The caps of strawberries dried and shriveled at ozone concentrations of 0.5 ppM and higher. Ozone in concentrations up to 10 ppM had no commercially significant effect on the fungi causing rhizopus andmore » brown rots of peaches at 60/sup 0/ temperature and 95% relative humidity; and no conclusive differences were obtained when peaches were held at ozone concentrations up to 0.7 ppM at either 50/sup 0/ for 2 days of 36/sup 0/ for 7 days and then at 70/sup 0/ for 4 days in the air. At ozone concentrations above 0.5 ppM, injury to peaches appeared as brown sunken areas at the stomata, producing a pebbly effect. At ozone concentrations of 0.5 ppM and higher, the surface growth of mold on strawberries and peaches was inhibited. At low concentrations of ozone the outer leaves of head lettuce were injured. 17 references, 7 figures, 5 tables.« less
Ultra-accelerated natural sunlight exposure testing
Jorgensen, Gary J.; Bingham, Carl; Goggin, Rita; Lewandowski, Allan A.; Netter, Judy C.
2000-06-13
Process and apparatus for providing ultra accelerated natural sunlight exposure testing of samples under controlled weathering without introducing unrealistic failure mechanisms in exposed materials and without breaking reciprocity relationships between flux exposure levels and cumulative dose that includes multiple concurrent levels of temperature and relative humidity at high levels of natural sunlight comprising: a) concentrating solar flux uniformly; b) directing the controlled uniform sunlight onto sample materials in a chamber enclosing multiple concurrent levels of temperature and relative humidity to allow the sample materials to be subjected to accelerated irradiance exposure factors for a sufficient period of time in days to provide a corresponding time of about at least a years worth of representative weathering of the sample materials.
Hubert, Jan; Pekár, Stano; Aulický, Radek; Nesvorná, Marta; Stejskal, Václav
2013-06-01
The rate of population increase of three mite species, Acarus siro (L.), Lepidoglyphus destructor (Schrank) and Tyrophagus putrescentiae (Schrank), was studied on various types of barley and at various combinations of temperature and humidity. The mites were added into the chambers and incubated for 21 days on seven different kinds of barley coming from four sites, including six cultivars and a mixture. The population increase of all species was higher on the mixture than on any other cultivar, except for Sebastian and Calgary. The increase of mites was studied at constant temperatures ranging from 5 to 35 °C and relative humidity (RH) ranging from 50 to 90 %. Positive rate of increase was found above 70 % RH for all species. The optimal humidity was at 85 % RH for A. siro and L. destructor and at 90 % RH for T. putrescentiae. As concerns the temperature, positive rate of increase was found at temperatures higher than 10, 15 and 20 °C for A. siro, L. destructor and T. putrescentiae, respectively. The temperature optima were at 23, 25, and 30 °C for A. siro, L. destructor and T. putrescentiae, respectively. Model estimated on laboratory data was then fitted to temperature and humidity records from August to November in the Czech grain store. Estimated population rate of increase was rarely positive: for A. siro it was for 24 %, for L. destructor for only 1 % and for T. putrescentiae for only 7 % days of the study period. It is concluded that in the climatic conditions of the Czech Republic the population increase of three mite pests is negligible during autumn and winter.
Schwerbrock, R; Leuschner, C
2016-07-01
(1) Most ferns are restricted to moist and shady habitats, but it is not known whether soil moisture or atmospheric water status are decisive limiting factors, or if both are equally important. (2) Using the rare temperate woodland fern Polystichum braunii, we conducted a three-factorial climate chamber experiment (soil moisture (SM) × air humidity (RH) × air temperature (T)) to test the hypotheses that: (i) atmospheric water status (RH) exerts a similarly large influence on the fern's biology as soil moisture, and (ii) both a reduction in RH and an increase in air temperature reduce vigour and growth. (3) Nine of 11 morphological, physiological and growth-related traits were significantly influenced by an increase in RH from 65% to 95%, leading to higher leaf conductance, increased above- and belowground productivity, higher fertility, more epidermal trichomes and fewer leaf deformities under high air humidity. In contrast, soil moisture variation (from 66% to 70% in the moist to ca. 42% in the dry treatment) influenced only one trait (specific leaf area), and temperature variation (15 °C versus 19 °C during daytime) only three traits (leaf conductance, root/shoot ratio, specific leaf area); RH was the only factor affecting productivity. (4) This study is the first experimental proof for a soil moisture-independent air humidity effect on the growth of terrestrial woodland ferns. P. braunii appears to be an air humidity hygrophyte that, whithin the range of realistic environmental conditions set in this study, suffers more from a reduction in RH than in soil moisture. A climate warming-related increase in summer temperatures, however, seems not to directly threaten this endangered species. © 2016 German Botanical Society and The Royal Botanical Society of the Netherlands.
NASA Astrophysics Data System (ADS)
Montalbano, Timothy
Gas turbine engines remain an integral part of providing the world's propulsion and power generation needs. The continued use of gas turbines requires increased temperature operation to reach higher efficiencies and the implementation of alternative fuels for a lower net-carbon footprint. This necessitates evaluation of the material coatings used to shield the hot section components of gas turbines in these new extreme environments in order to understand how material degradation mechanisms change. Recently, the US Navy has sought to reduce its use of fossil fuels by implementing a blended hydroprocessed renewable diesel (HRD) derived from algae in its fleet. To evaluate the material degradation in this alternative environment, metal alloys are exposed in a simulated combustion environment using this blended fuel or the traditional diesel-like fuel. Evaluation of the metal alloys showed the development of thick, porous scales with a large depletion of aluminum for the blend fuel test. A mechanism linking an increased solubility of the scale to the blend fuel test environment will be discussed. For power generation applications, Integrated Gasification Combined Cycle (IGCC) power plants can provide electricity with 45% efficiency and full carbon capture by using a synthetic gas (syngas) derived from coal, biomass, or another carbon feedstock. However, the combustion of syngas is known to cause high water vapor content levels in the exhaust stream with unknown material consequences. To evaluate the effect of increased humidity, air-plasma sprayed (APS), yttria-stabilized zirconia (YSZ) is thermally aged in an environment with and without humidity. An enhanced destabilization of the parent phase by humid aging is revealed by x-ray diffraction (XRD) and Raman spectroscopy. Microstructural analysis by transmission electron microscopy (TEM) and scanning-TEM (STEM) indicate an enhanced coarsening of the domain structure of the YSZ in the humid environment. The enhanced destabilization and coarsening in the humid aging environment is explained mechanistically by water-derived species being incorporated into the YSZ structure and altering the anion sublattice. The characterization of the metal alloy and ceramic coatings exposed in these alternative environments allows for a deeper understanding of the mechanisms behind the material evolution in these environments.
3. DETAIL OF RACKS AND TEMPERATURE/HUMIDITY CONTROL SYSTEM IN CURING ...
3. DETAIL OF RACKS AND TEMPERATURE/HUMIDITY CONTROL SYSTEM IN CURING ROOM ON LEVEL 6; LOOKING SOUTHEAST; ENVIRONMENT INSIDE THE CURING ROOM WAS CONTROLLED BY NIAGARA MODEL 87007 SPRAY COOLER AND BUFFALO FORGE CENTRIFUGAL FAN IN BACKGROUND - Rath Packing Company, Cooler Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
Hygrothermal Anaylsis of Wood-Frame Wall Assemblies in a Mixed-Humid Climate
Samuel V. Glass
2013-01-01
This study uses a one-dimensional hygrothermal model to investigate the moisture performance of 10 residential wood-frame wall assemblies in a representative mixed-humid climate location of Baltimore, Maryland (climate zone 4A). All the assemblies include oriented strandboard (OSB) sheathing and vinyl siding. The walls differ in stud cavity thickness, level of cavity...
Kortesniemi, Maaria; Sinkkonen, Jari; Yang, Baoru; Kallio, Heikki
2014-03-15
¹H NMR spectroscopy and multivariate data analysis were applied to the metabolic profiling and discrimination of wild sea buckthorn (Hippophaë rhamnoides L.) berries from different locations in Finland (subspecies (ssp.) rhamnoides) and China (ssp. sinensis). Principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA) showed discrimination of the two subspecies and different growth sites. The discrimination of ssp. rhamnoides was mainly associated with typically higher temperature, radiation and humidity and lower precipitation in the south, yielding higher levels of O-ethyl β-d-glucopyranoside and d-glucose, and lower levels of malic, quinic and ascorbic acids. Significant metabolic differences (p<0.05) in genetically identical berries were observed between latitudes 60° and 67° north in Finland. High altitudes (> 2,000 m) correlated with greater levels of malic and ascorbic acids in ssp. sinensis. The NMR metabolomics approach applied here is effective for identification of metabolites, geographical origin and subspecies of sea buckthorn berries. Copyright © 2013 Elsevier Ltd. All rights reserved.
Propagation of sound through the Earth's atmosphere
NASA Technical Reports Server (NTRS)
Meredith, R. W.; Becher, J.
1983-01-01
The data collected at a pressure of one atmosphere for the different temperatures and relative humidities of the air-water vapor mixtures is summarized. The dew point hygrometer used in these measurements did not give reliable results for dew points much above the ambient room temperature. For this reason measurements were not attempted at the higher temperatures and humidities. Viscous wall losses in the resonant tube at 0 C so dominate the molecular relaxation of nitrogen, in the air-water vapor mixture, that reliable data could not be obtained using the free decay method in a resonant tube at one atmosphere. In an effort to obtain viable data at these temperatures, measurements were performed at a pressure of 10 atmospheres. Since the molecular relaxation peak is proportional to the pressure and the viscous losses are proportional to the inverse square root of the pressure the peak height should be measurable at the higher pressure. The tradeoff here is that at 10 atmospheres; the highest relative humidity attainable is 10 percent. The data collected at 10 atmospheres is also summarized.
Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador
NASA Astrophysics Data System (ADS)
Johansson, Erik; Yahia, Moohammed Wasim; Arroyo, Ivette; Bengs, Christer
2018-03-01
The thermal environment outdoors affects human comfort and health. Mental and physical performance is reduced at high levels of air temperature being a problem especially in tropical climates. This paper deals with human comfort in the warm-humid city of Guayaquil, Ecuador. The main aim was to examine the influence of urban micrometeorological conditions on people's subjective thermal perception and to compare it with two thermal comfort indices: the physiologically equivalent temperature (PET) and the standard effective temperature (SET*). The outdoor thermal comfort was assessed through micrometeorological measurements of air temperature, humidity, mean radiant temperature and wind speed together with a questionnaire survey consisting of 544 interviews conducted in five public places of the city during both the dry and rainy seasons. The neutral and preferred values as well as the upper comfort limits of PET and SET* were determined. For both indices, the neutral values and upper thermal comfort limits were lower during the rainy season, whereas the preferred values were higher during the rainy season. Regardless of season, the neutral values of PET and SET* are above the theoretical neutral value of each index. The results show that local people accept thermal conditions which are above acceptable comfort limits in temperate climates and that the subjective thermal perception varies within a wide range. It is clear, however, that the majority of the people in Guayaquil experience the outdoor thermal environment during daytime as too warm, and therefore, it is important to promote an urban design which creates shade and ventilation.
Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D
2015-07-01
Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.
Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador.
Johansson, Erik; Yahia, Moohammed Wasim; Arroyo, Ivette; Bengs, Christer
2018-03-01
The thermal environment outdoors affects human comfort and health. Mental and physical performance is reduced at high levels of air temperature being a problem especially in tropical climates. This paper deals with human comfort in the warm-humid city of Guayaquil, Ecuador. The main aim was to examine the influence of urban micrometeorological conditions on people's subjective thermal perception and to compare it with two thermal comfort indices: the physiologically equivalent temperature (PET) and the standard effective temperature (SET*). The outdoor thermal comfort was assessed through micrometeorological measurements of air temperature, humidity, mean radiant temperature and wind speed together with a questionnaire survey consisting of 544 interviews conducted in five public places of the city during both the dry and rainy seasons. The neutral and preferred values as well as the upper comfort limits of PET and SET* were determined. For both indices, the neutral values and upper thermal comfort limits were lower during the rainy season, whereas the preferred values were higher during the rainy season. Regardless of season, the neutral values of PET and SET* are above the theoretical neutral value of each index. The results show that local people accept thermal conditions which are above acceptable comfort limits in temperate climates and that the subjective thermal perception varies within a wide range. It is clear, however, that the majority of the people in Guayaquil experience the outdoor thermal environment during daytime as too warm, and therefore, it is important to promote an urban design which creates shade and ventilation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berlin, G.
Humidity plays a major role in health, comfort, and production. This article is a brief overview of the technologies available and a detailed explanation of how to calculate humidification loads. The problems caused by dry air vary from one building to another and from one area to another. But basically, there are three major problem types: static electricity, poor moisture stability, health and comfort problems. In today's business offices, static electricity can disrupt operations and increase operating costs. In printing facilities, low humidity causes poor ink registration. Also, sheets of paper stick together and jam machines, wasting time and paper.more » In computer rooms and data processing areas, dry air leads to static electric discharges that cause circuit board failure, dust buildup on heads, and storage tape breakage. Moisture stability impacts industrial processes and the materials they use. In many cases, product and material deterioration is directly related to moisture fluctuations and lack of humidity control. Books, antiques, paper, wood and wood products, and fruits and vegetables are a few items that can be ruined by low or changing humidity. The health impact of low humidity shows up in dry nasal and thread membranes, dry and itchy skin, and irritated eyes. For employees, this means greater susceptibility to colds and other viral infections. The results is higher absenteeism when humidity is low, which translates into lost productivity and profits.« less
NASA Astrophysics Data System (ADS)
Zhang, S.; Jing, X.
2017-12-01
Rainwater harvesting is now increasingly used to manage urban flood and alleviate water scarcity crisis. In this study, a computational tool based on water balance equation is developed to assess stormwater capture and water saving efficiency and economic viability of rainwater harvesting systems (RHS) in eight cities across four climatic zones of China. It requires daily rainfall, contributing area, runoff losses, first flush volume, storage capacity, daily water demand and economic parameters as inputs. Three non-potable water demand scenarios (i.e., toilet flushing, lawn irrigation, and combination of them) are considered. The water demand for lawn irrigation is estimated using the Cropwat 8.0 and Climwat 2.0. Results indicate that higher water saving efficiency and water supply time reliability can be achieved for RHS with larger storage capacities, for lower water demand scenarios and located in more humid regions, while higher stormwater capture efficiency is associated with larger storage capacity, higher water demand scenarios and less rainfall. For instance, a 40 m3 RHS in Shanghai (humid climate) for lawn irrigation can capture 17% of stormwater, while its water saving efficiency and time reliability can reach 96 % and 98%, respectively. The water saving efficiency and time reliability of a 20 m3 RHS in Xining (semi-arid climate) for toilet flushing are 19% and 16%, respectively, but it can capture 63% of stormwater. With the current values of economic parameters, economic viability of RHS can be achieved in humid and semi-humid regions for reasonably designed RHS; however, it is not financially viable to install RHS in arid regions as the benefit-cost ratio is much smaller than 1.0.
NASA Astrophysics Data System (ADS)
Yang, Xiaojuan; Thornton, Peter E.; Ricciuto, Daniel M.; Hoffman, Forrest M.
2016-07-01
The effects of phosphorus (P) availability on carbon (C) cycling in the Amazon region are investigated using CLM-CNP. We demonstrate that the coupling of P dynamics reduces the simulated historical terrestrial C sink due to increasing atmospheric CO2 concentrations ([CO2]) by about 26%. Our exploratory simulations show that the response of tropical forest C cycling to increasing [CO2] depends on how elevated CO2 affects phosphatase enzyme production. The effects of warming are more complex, depending on the interactions between humidity, C, and nutrient dynamics. While a simulation with low humidity generally shows the reduction of net primary productivity (NPP), a second simulation with higher humidity suggests overall increases in NPP due to the dominant effects of reduced water stress and more nutrient availability. Our simulations point to the need for (1) new observations on how elevated [CO2] affects phosphatase enzyme production and (2) more tropical leaf-scale measurements under different temperature/humidity conditions with different soil P availability.
Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method
NASA Technical Reports Server (NTRS)
Burkett, Cecil G.; West, James W.; Levine, Joel S.
2004-01-01
The relative humidity of the atmosphere in the encasements containing the U.S. Constitution Pages 1 and 4, the Declaration of Independence, and the Bill of Rights was measured to be in the range of 55% to 61%. This value is significantly higher than the presumed relative humidity between 25 to 35 %, but is consistent with the measured samples extracted from Pages 2 and 3 of the U.S. Constitution. The cooling/condensation measurement technique used at NARA on July 23, 2001, and described in this paper to measure the water vapor content of the atmosphere in the hermetically sealed encasements containing the U. S. Constitution, the Declaration of Independence, and the Bill of Rights, proved to be a powerful new measurement technique. The cooling/condensation technique developed at NASA LaRC and utilized at NARA has important applications in the non-invasive measurement of relative humidity in the atmospheres of sealed encasements and could become a standard measurement technique in this type of analysis.
Oke, O E
2018-06-01
Dietary manipulation has been seen as one of the practical ways to ameliorate the adverse effects of thermal stress in the hot humid tropical climate. In order to investigate the influence of Curcuma longa (turmeric) rhizome powder on physiological responses and performance under hot humid tropical climate, 240 broiler chicks were randomly assigned to four dietary treatments having four replicates of 15 birds each in a complete randomized design. Broiler birds were fed basal diets and supplemented with 0 (CT), 4 (TG), 8 (FT), and 12 g (SG) of turmeric powder/kg of diet for 8 weeks. Data were collected weekly on feed intake and body weights. Blood samples were collected from eight birds per treatment at week 4 (starter phase) and week 8 (finisher phase) of the experiment for the determination of plasma 3,5,3'-triiodothyronine (T 3 ), superoxide dismutase (SOD), malondialdehyde (MDA). Rectal temperature of the birds was also taken. At 56 days of age, eight birds from each treatment were slaughtered for the determination of relative organ weights. Results showed that the final weights of the birds in FT were significantly higher than those of the birds in TG, SG, and CT. The weight gain of the birds in FT was higher than those of the birds in SG while those of SG were higher than those of TG whose values were higher than that of CT. The feed conversion ratio of the broiler chickens in CT was higher (P < 0.05) than those of other treatment groups while the birds in FT and SG had similar feed conversion ratios. SOD of birds fed turmeric rhizome powder was higher than the birds in the control group at both starter and finisher phases. Furthermore, MDA of the birds in FT was lower than those of the birds in the other treatment groups at the finisher phase. Plasma T 3 was higher in the birds fed turmeric at the finisher phase than chickens in the control group. There was no difference in the rectal temperatures of the birds. To conclude, turmeric rhizome powder improved the physiological response and performance of broiler chicken under hot humid tropical climate in a dose-dependent characteristic and the optimum supplementation rate of 8 g/kg of diet was recorded.
CrossVit: enhancing canopy monitoring management practices in viticulture.
Matese, Alessandro; Vaccari, Francesco Primo; Tomasi, Diego; Di Gennaro, Salvatore Filippo; Primicerio, Jacopo; Sabatini, Francesco; Guidoni, Silvia
2013-06-13
A new wireless sensor network (WSN), called CrossVit, and based on MEMSIC products, has been tested for two growing seasons in two vineyards in Italy. The aims are to evaluate the monitoring performances of the new WSN directly in the vineyard and collect air temperature, air humidity and solar radiation data to support vineyard management practices. The WSN consists of various levels: the Master/Gateway level coordinates the WSN and performs data aggregation; the Farm/Server level takes care of storing data on a server, data processing and graphic rendering; Nodes level is based on a network of peripheral nodes consisting of a MDA300 sensor board and Iris module and equipped with thermistors for air temperature, photodiodes for global and diffuse solar radiation, and an HTM2500LF sensor for relative humidity. The communication levels are: WSN links between gateways and sensor nodes by ZigBee, and long-range GSM/GPRS links between gateways and the server farm level. The system was able to monitor the agrometeorological parameters in the vineyard: solar radiation, air temperature and air humidity, detecting the differences between the canopy treatments applied. The performance of CrossVit, in terms of monitoring and reliability of the system, have been evaluated considering: its handiness, cost-effective, non-invasive dimensions and low power consumption.
CrossVit: Enhancing Canopy Monitoring Management Practices in Viticulture
Matese, Alessandro; Vaccari, Francesco Primo; Tomasi, Diego; Di Gennaro, Salvatore Filippo; Primicerio, Jacopo; Sabatini, Francesco; Guidoni, Silvia
2013-01-01
A new wireless sensor network (WSN), called CrossVit, and based on MEMSIC products, has been tested for two growing seasons in two vineyards in Italy. The aims are to evaluate the monitoring performances of the new WSN directly in the vineyard and collect air temperature, air humidity and solar radiation data to support vineyard management practices. The WSN consists of various levels: the Master/Gateway level coordinates the WSN and performs data aggregation; the Farm/Server level takes care of storing data on a server, data processing and graphic rendering; Nodes level is based on a network of peripheral nodes consisting of a MDA300 sensor board and Iris module and equipped with thermistors for air temperature, photodiodes for global and diffuse solar radiation, and an HTM2500LF sensor for relative humidity. The communication levels are: WSN links between gateways and sensor nodes by ZigBee, and long-range GSM/GPRS links between gateways and the server farm level. The system was able to monitor the agrometeorological parameters in the vineyard: solar radiation, air temperature and air humidity, detecting the differences between the canopy treatments applied. The performance of CrossVit, in terms of monitoring and reliability of the system, have been evaluated considering: its handiness, cost-effective, non-invasive dimensions and low power consumption. PMID:23765273
Santurtún, Ana; Ruiz, Patricia Bolivar; López-Delgado, Laura; Sanchez-Lorenzo, Arturo; Riancho, Javier; Zarrabeitia, María T
2017-07-01
Stroke, the second cause of death and the most frequent cause of severe disability among adults in developed countries, is related to a large variety of risk factors. This paper assesses the temporal patterns in stroke episodes in a city in Northern Spain during a 12-year period and analyzes the possible effects that atmospheric pollutants and meteorological variables may have on stroke on a daily scale. Our results show that there is an increase in stroke admissions (r = 0.818, p = 0.001) especially in patients over 85 years old. On a weekly scale, the number of hospital admissions due to stroke remains stable from Monday to Friday, whereas it abruptly decreases during the weekends, reaching its minimum values on Sunday (p < 0.005); however, mortality in patients admitted to the hospital is higher on Sundays than on other days of the week. Finally, a statistically significant positive correlation between the number of stroke hospital admissions and NO 2 levels (p = 0.012) and an inverse correlation with relative humidity (p = 0.032) were found. The analysis of the relationship between ischemic strokes and atmospheric circulation shows a higher frequency of the former in Santander with enhanced negative air pressure anomalies over western Spain; the fact that under these conditions the region studied registers very low values of relative humidity is in line with the aforementioned inverse correlation, which has not been described elsewhere in the literature. This study could be a first step for implementing stroke alert protocols depending on air pollution levels and circulation patterns forecasts.
NASA Astrophysics Data System (ADS)
El-Tarabany, Mahmoud Salah
2016-07-01
The aim of this study was to investigate the effect of temperature-humidity index (THI) level on productive parameters, welfare, and immunity in Japanese quails. One hundred and eighty (180) birds of Japanese quail, 14 weeks old, were used. Birds were divided randomly into three equal groups, control (at low THI, less than 70), H1 (at moderate THI, 70-75), and H2 (at high THI, 76-80). Birds in the control group had higher body weight (281.2 g, p = 0.001), egg mass (745 g, p = 0.001), fertility (85.4 %, p = 0.039), hatchability (80.4 %, p = 0.001), and immune response titer to Newcastle disease virus ( p = 0.031), compared with H2 group. Furthermore, the thermoneutral group had higher internal egg quality score [albumen height (5.14 mm, p = 0.001), yolk height (10.88 mm, p = 0.015), yolk index (42.32 %, p = 0.039), and Haugh unit (92.67, p = 0.001)]. Nevertheless, there were no significant differences in fertility percentage, immune response, and corticosterone concentration between control and H1 group. Birds in the H2 group had the lowest total leucocytic count and lymphocyte percentage ( p = 0.001 and 0.020, respectively) but the highest H/L ratio (0.83, p = 0.001). Corticosterone concentration was lower in control and H1 groups (5.49 and 6.41 ng/mL, respectively, p = 0.024) than that in H2 group. Japanese quail exposed to heat stress revealed drop in production and immunological parameters, as well as a detrimental effects on welfare. Thus, practical approaches might be used to reduce the detrimental effects of greater THI level.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, W.P.
This patent describes a solar energy system. It comprises: a water pond which is heated by solar energy; a cover above the pond which transmits solar energy; an air space between the pond and the cover through which warm air and vaporized water move; a chimney which induces the rapid flow of warm humid air into its lower end and delivers such air at its upper end; a fresh water heat sink which receives condensed vapor from the chimney-induced flow; a heat energy driven engine, the power output of which is a function of the temperature difference between higher andmore » lower temperature levels; a first heat exchanger in the engine connected to the top of the chimney, and arranged to convert the vapor condensation energy into the higher temperature level of th engine; a second heat exchanger in the engine arranged to provide the lower temperature of the engine by connection to the heat sink; and power transfer means driven by the temperature differential energy of the engine.« less
Polyimide-Based Capacitive Humidity Sensor
Steinmaßl, Matthias; Endres, Hanns-Erik; Drost, Andreas; Eisele, Ignaz; Kutter, Christoph; Müller-Buschbaum, Peter
2018-01-01
The development of humidity sensors with simple transduction principles attracts considerable interest by both scientific researchers and industrial companies. Capacitive humidity sensors, based on polyimide sensing material with different thickness and surface morphologies, are prepared. The surface morphology of the sensing layer is varied from flat to rough and then to nanostructure called nanograss by using an oxygen plasma etch process. The relative humidity (RH) sensor selectively responds to the presence of water vapor by a capacitance change. The interaction between polyimide and water molecules is studied by FTIR spectroscopy. The complete characterization of the prepared capacitive humidity sensor performance is realized using a gas mixing setup and an evaluation kit. A linear correlation is found between the measured capacitance and the RH level in the range of 5 to 85%. The morphology of the humidity sensing layer is revealed as an important parameter influencing the sensor performance. It is proved that a nanograss-like structure is the most effective for detecting RH, due to its rapid response and recovery times, which are comparable to or even better than the ones of commercial polymer-based sensors. This work demonstrates the readiness of the developed RH sensor technology for industrialization. PMID:29751632
NASA Technical Reports Server (NTRS)
Perlwitz, Jan; Miller, Ron L.
2010-01-01
We reexamine the aerosol semidirect effect using a general circulation model and four cases of the single-scattering albedo of dust aerosols. Contrary to the expected decrease in low cloud cover due to heating by tropospheric aerosols, we find a significant increase with increasing absorptivity of soil dust particles in regions with high dust load, except during Northern Hemisphere winter. The strongest sensitivity of cloud cover to dust absorption is found over land during Northern Hemisphere summer. Here even medium and high cloud cover increase where the dust load is highest. The cloud cover change is directly linked to the change in relative humidity in the troposphere as a result of contrasting changes in specific humidity and temperature. More absorption by aerosols leads to larger diabatic heating and increased warming of the column, decreasing relative humidity. However, a corresponding increase in the specific humidity exceeds the temperature effect on relative humidity. The net effect is more low cloud cover with increasing aerosol absorption. The higher specific humidity where cloud cover strongly increases is attributed to an enhanced convergence of moisture driven by dust radiative heating. Although in some areas our model exhibits a reduction of low cloud cover due to aerosol heating consistent with the conventional description of the semidirect effect, we conclude that the link between aerosols and clouds is more varied, depending also on changes in the atmospheric circulation and the specific humidity induced by the aerosols. Other absorbing aerosols such as black carbon are expected to have a similar effect.
NASA Astrophysics Data System (ADS)
Li, Yapeng; Wang, Xi-Ling; Zheng, Xueying
2018-05-01
Accumulating evidence demonstrates the significant influence of weather factors, especially temperature and humidity, on influenza seasonality. However, it is still unclear whether temperature variation within the same day, that is diurnal temperature range (DTR), is related to influenza seasonality. In addition, the different effects of weather factors on influenza seasonality across age groups have not been well documented in previous studies. Our study aims to explore the effects of DTR and humidity on influenza seasonality, and the differences in the association between weather factors and influenza seasonality among different age groups in Hong Kong, China. Generalized additive models were conducted to flexibly assess the impact of DTR, absolute humidity (vapor pressure, VP), and relative humidity on influenza seasonality in Hong Kong, China, from January 2012 to December 2016. Stratified analyses were performed to determine if the effects of weather factors differ across age groups (< 5, 5-9, 10-64, and > 64 years). The results suggested that DTR, absolute humidity, and relative humidity were significantly related to influenza seasonality in dry period (when VP is less than 20 mb), while no significant association was found in humid period (when VP is greater than 20 mb). The percentage changes of hospitalization rates due to influenza associated with per unit increase of weather factors in the very young children (age 0-4) and the elderly (age 65+) were higher than that in the adults (age 10-64). Diurnal temperature range is significantly associated with influenza seasonality in dry period, and the effects of weather factors differ across age groups in Hong Kong, China.
Spiker, E. C.; Hosker, R.P.; Weintraub, V.C.; Sherwood, S.I.
1995-01-01
The dry deposition of gaseous air pollutants on stone and other materials is influenced by atmospheric processes and the chemical characteristics of the deposited gas species and of the specific receptor material. Previous studies have shown that relative humidity, surface moisture, and acid buffering capability of the receptor surface are very important factors. To better quantify this behavior, a special recirculating wind tunnel/environmental chamber was constructed, in which wind speed, turbulence, air temperature, relative humidity, and concentrations of several pollutants (SO2, O3, nitrogen oxides) can be held constant. An airfoil sample holder holds up to eight stone samples (3.8 cm in diameter and 1 cm thick) in nearly identical exposure conditions. SO2 deposition on limestone was found to increase exponentially with increasing relative humidity (RH). Marble behaves similarly, but with a much lower deposition rate. Trends indicate there is little deposition below 20% RH on clean limestone and below 60% RH on clean marble. This large difference is due to the limestone's greater porosity, surface roughness, and effective surface area. These results indicate surface variables generally limit SO2 deposition below about 70% RH on limestone and below at least 95% RH on marble. Aerodynamic variables generally limit deposition at higher relative humidity or when the surface is wet.The dry deposition of gaseous air pollutants on stone and other materials is influenced by atmospheric processes and the chemical characteristics of the deposited gas species and of the specific receptor material. Previous studies have shown that relative humidity, surface moisture, and acid buffering capability of the receptor surface are very important factors. To better quantify this behavior, a special recirculating wind tunnel/environmental chamber was constructed, in which wind speed, turbulence, air temperature, relative humidity, and concentrations of several pollutants (SO2, O3, nitrogen oxides) can be held constant. An airfoil sample holder holds up to eight stone samples (3.8 cm in diameter and 1 cm thick) in nearly identical exposure conditions. SO2 deposition on limestone was found to increase exponentially with increasing relative humidity (RH). Marble behaves similarly, but with a much lower deposition rate. Trends indicate there is little deposition below 20% RH on clean limestone and below 60% RH on clean marble. This large difference is due to the limestone's greater porosity, surface roughness, and effective surface area. These results indicate surface variables generally limit SO2 deposition below about 70% RH on limestone and below at least 95% RH on marble. Aerodynamic variables generally limit deposition at higher relative humidity or when the surface is wet.
The observation-based relationships between PM2.5 and AOD over China
NASA Astrophysics Data System (ADS)
Xin, Jinyuan; Gong, Chongshui; Liu, Zirui; Cong, Zhiyuan; Gao, Wenkang; Song, Tao; Pan, Yuepeng; Sun, Yang; Ji, Dongsheng; Wang, Lili; Tang, Guiqian; Wang, Yuesi
2016-09-01
This is the first investigation of the generalized linear regressions of PM2.5 and aerosol optical depth (AOD) with the Campaign on atmospheric Aerosol Research-China network over the large high-concentration aerosol region during the period from 2012 to 2013. The map of the PM2.5 and AOD levels showed large spatial differences in the aerosol concentrations and aerosol optical properties over China. The ranges of the annual mean PM2.5 and AOD were 10-117 µg/m3 and 0.12-1.11 from the clean regions to seriously polluted regions, from the almost "arctic" and the Tibetan Plateau to tropical environments. There were significant spatial agreements and correlations between the PM2.5 and AOD. However, the linear regression functions (PM2.5 = A*AOD + B) exhibited large differences in different regions and seasons. The slopes (A) were from 13 to 90, the intercepts (B) were from 0.8 to 33.3, and the correlation coefficients (R2) ranged from 0.06 to 0.75. The slopes (A) were much higher in the north (41-99) than in the south (13-64) because the extinction efficiency of hygroscopic aerosol was rapidly increasing with the increasing humidity from the dry north to the humid south. Meanwhile, the intercepts (B) were generally lower, and the correlation coefficients (R2) were much higher in the dry north than in the humid south. There was high consistency of AOD versus PM2.5 for all sites in three ranges of the atmospheric column precipitable water vapor (PWV). The segmented linear regression functions were y = 84.66x + 9.85 (PWV < 1.0), y = 69.47x + 11.87 (1.0 < PWV < 2.5), and y = 52.37x + 8.59 (PWV > 2.5). The correlation coefficients (R2) were high from 0.64 to 0.70 across China.
NASA Astrophysics Data System (ADS)
Wu, Yi-Hua; Chan, Chang-Chuan; Rao, Carol Y.; Lee, Chung-Te; Hsu, Hsiao-Hsien; Chiu, Yueh-Hsiu; Chao, H. Jasmine
This study was conducted to investigate the temporal and spatial distributions, compositions, and determinants of ambient aeroallergens in Taipei, Taiwan, a subtropical metropolis. We monitored ambient culturable fungi in Shin-Jhuang City, an urban area, and Shi-Men Township, a rural area, in Taipei metropolis from 2003 to 2004. We collected ambient fungi in the last week of every month during the study period, using duplicate Burkard portable samplers and Malt Extract Agar. The median concentration of total fungi was 1339 colony-forming units m -3 of air over the study period. The most prevalent fungi were non-sporulating fungi, Cladosporium, Penicillium, Curvularia and Aspergillus at both sites. Airborne fungal concentrations and diversity of fungal species were generally higher in urban than in rural areas. Most fungal taxa had significant seasonal variations, with higher levels in summer. Multivariate analyses showed that the levels of ambient fungi were associated positively with temperature, but negatively with ozone and several other air pollutants. Relative humidity also had a significant non-linear relationship with ambient fungal levels. We concluded that the concentrations and the compositions of ambient fungi are diverse in urban and rural areas in the subtropical region. High ambient fungal levels were related to an urban environment and environmental conditions of high temperature and low ozone levels.
Arduino Based Infant Monitoring System
NASA Astrophysics Data System (ADS)
Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi
2017-08-01
This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.
Angelo, T; Barbalho, G N; Gelfuso, G M; Gratieri, T
2016-09-01
There is yet no consensus among prescribers whether minoxidil (MXD) formulations should be applied on wet/damp or dry scalp and no clear FDA guidelines on the matter. We hypothesized that the use of MXD on damp scalp may lead to higher drug penetration. First, because the drug diffusion and consequent deposition into the hair follicle may be favored when follicle cast is humid. Second, because humidity may also prevent drug crystallization and, therefore, maintain a higher thermodynamic activity for longer periods, which leads to increased penetration. Following in vitro experiments on rat and porcine skin we confirmed the hypothesis, which could markedly improve treatment effectiveness. © 2016 Wiley Periodicals, Inc.
Seasonal variation in the incidence of preeclampsia and eclampsia in tropical climatic conditions.
Subramaniam, Vidya
2007-10-15
Observational studies have demonstrated various correlations between hypertensive disorders of pregnancy and different weather parameters. We aim to study if a correlation exists between the incidence of eclampsia and pre-eclampsia and various weather parameters in the tropical coastal city of Mumbai which has the distinction of having relatively uniform meteorological variables all throughout the year, except for the monsoon season. We retrospectively analysed data from a large maternity centre in Mumbai, India over a period of 36 months from March 1993 to February 1996, recording the incidence of preeclampsia and eclampsia. Meteorological data was acquired from the regional meteorological centre recording the monthly average temperature, humidity, barometric pressure and rainfall during the study period. Study period was then divided into two climate conditions: monsoon season (June to August) and dry season September to May. The incidence of preeclampsia and eclampsia and the meteorological differences between the two seasons were compared. Over a 36-month period, a total of 29562 deliveries were recorded, of which 1238 patients developed preeclampsia (4.18%) and 34 developed eclampsia (0.11%). The incidence of preeclampsia did not differ between the monsoon and the dry season (4.3% vs. 4.15%, p = 0.5). The incidence of eclampsia was significantly higher in the monsoon (0.2% vs. 0.08%, p = 0.01). The monsoon was significantly cooler (median maximum temperature 30.7 degrees C vs. 32.3 degrees C, p = 0.01), more humid (median relative humidity 85% vs. 70%, p = 0.0008), and received higher rainfall (median 504.9 mm vs. 0.3 mm, p = 0.0002) than the rest of the year. The median barometric pressure (1005 mb) during the monsoon season was significantly lower than the rest of the year (1012 mb, p < 0.0001). In the tropical climate of Mumbai, the incidence of eclampsia is significantly higher in monsoon, when the weather is cooler and humid with a lower barometric pressure than the rest of the year. This effect is not seen with preeclampsia. This strengthens the association of low temperature and high humidity with triggering of eclampsia.
Adaptive observer-based control for an IPMC actuator under varying humidity conditions
NASA Astrophysics Data System (ADS)
Bernat, Jakub; Kolota, Jakub
2018-05-01
As ionic polymer metal composites (IPMC) are increasingly applied to mechatronic systems, many new IPMC modeling efforts have been reported in the literature. The demands of rapidly growing technology has generated interest in advancing the intrinsic actuation and sensing capabilities of IPMC. Classical IPMC applications need constant hydration to operate. On the other hand, for IPMCs operating in air, the water content of the polymer varies with the humidity level of the ambient environment, which leads to its strong humidity-dependent behavior. Furthermore, decreasing water content over time plays a crucial role in the effectiveness of IPMC. Therefore, the primary challenge of this work is to accurately model this phenomenon. The principal contribution of the paper is a new IPMC model, which considers the change of moisture content. A novel nonlinear adaptive observer is designed to determine the unknown electric potential and humidity level in the polymer membrane. This approach effectively determines the moisture content of the IPMC during long-term continuous operation in air. This subsequently allows us to develop an effective back-stepping control algorithm that considers varying moisture content. Data from experiments are presented to support the effectiveness of the observation process, which is shown in illustrative examples.
Seasonal mapping of NICU temperature.
Thomas, Karen A; Magbalot, Almita; Shinabarger, Kelley; Mokhnach, Larisa; Anderson, Marilyn; Diercks, Kristi; Millar, April; Thorngate, Lauren; Walker, Wendy; Dilback, Nancy; Berkan, Maureen
2010-04-01
To create a thermal map of ambient air, radiant, and evaporative temperatures and humidity throughout the NICU nursery by season across a calendar year. Each cubicle of the 32-bed NICU, distributed across 5 rooms, in a level III nursery was measured. Temperatures were recorded at a consistent time on one day during January, April, July, and October. An electronic monitor (QUESTemp degrees 34; Quest Technologies, Oconomowoc, Wisconsin) was used to measure dry bulb, wet bulb, and globe thermometer temperatures. Analysis of variance revealed statistically significant (P < .000) differences in season, room, and season by room interaction. Room ambient air temperatures differed by less than 2 degrees F across season. Radiant temperature paralleled air temperature. Humidity, the predominant difference across season, produced evaporative temperatures considerably lower than room air temperature, and the gradient between mean nursery dry bulb temperature and wet bulb temperature was 9.3 degrees F in summer and 16.8 degrees F in winter. The thermal map revealed seasonal thermal differences, particularly in humidity level and evaporative temperature. Room temperature alone does not reflect the total thermal environment. Recommendations include periodic assessment of nurseries along with air, evaporative, and radiant temperatures as well as humidity to fully appreciate the impact of the thermal environment on infants.
Seasonal mapping of NICU temperature.
Thomas, Karen A; Magbalot, Almita; Shinabarger, Kelley; Mokhnach, Larisa; Anderson, Marilyn; Diercks, Kristi; Millar, April; Thorngate, Lauren; Walker, Wendy; Dilback, Nancy; Berkan, Maureen
2010-10-01
To create a thermal map of ambient air, radiant, and evaporative temperatures and humidity throughout the NICU nursery by season across a calendar year. Each cubicle of the 32-bed NICU, distributed across 5 rooms, in a level III nursery was measured. Temperatures were recorded at a consistent time on one day during January, April, July, and October. : An electronic monitor (QUESTemp ° 34; Quest Technologies, Oconomowoc, Wisconsin) was used to measure dry bulb, wet bulb, and globe thermometer temperatures. Analysis of variance revealed statistically significant (P ≤ .000) differences in season, room, and season by room interaction. Room ambient air temperatures differed by less than 2 ° F across season. Radiant temperature paralleled air temperature. Humidity, the predominant difference across season, produced evaporative temperatures considerably lower than room air temperature, and the gradient between mean nursery dry bulb temperature and wet bulb temperature was 9.3 ° F in summer and 16.8 ° F in winter. The thermal map revealed seasonal thermal differences, particularly in humidity level and evaporative temperature. Room temperature alone does not reflect the total thermal environment. Recommendations include periodic assessment of nurseries along with air, evaporative, and radiant temperatures as well as humidity to fully appreciate the impact of the thermal environment on infants.
Bolger, C; Tufvesson, E; Anderson, S D; Devereux, G; Ayres, J G; Bjermer, L; Sue-Chu, M; Kippelen, P
2011-10-01
Injury to the airway epithelium has been proposed as a key susceptibility factor for exercise-induced bronchoconstriction (EIB). Our goals were to establish whether airway epithelial cell injury occurs during EIB in athletes and whether inhalation of warm humid air inhibits this injury. Twenty-one young male athletes (10 with a history of EIB) performed two 8-min exercise tests near maximal aerobic capacity in cold dry (4°C, 37% relative humidity) and warm humid (25°C, 94% relative humidity) air on separate days. Postexercise changes in urinary CC16 were used as a biomarker of airway epithelial cell perturbation and injury. Bronchoconstriction occurred in eight athletes in the cold dry environment and was completely blocked by inhalation of warm humid air [maximal fall in forced expiratory volume in 1 s = 18.1 ± 2.1% (SD) in cold dry air and 1.7 ± 0.8% in warm humid air, P < 0.01]. Exercise caused an increase in urinary excretion of CC16 in all subjects (P < 0.001), but this rise in CC16 was blunted following inhalation of warm humid air [median CC16 increase pre- to postchallenge = 1.91 and 0.35 ng/μmol in cold dry and warm humid air, respectively, in athletes with EIB (P = 0.017) and 1.68 and 0.48 ng/μmol in cold dry and warm humid air, respectively, in athletes without EIB (P = 0.002)]. The results indicate that exercise hyperpnea transiently disrupts the airway epithelium of all athletes (not only in those with EIB) and that inhalation of warm moist air limits airway epithelial cell perturbation and injury.
Dellweg, Dominic; Wenze, Markus; Hoehn, Ekkehard; Bourgund, Olaf; Haidl, Peter
2013-08-01
Oxygen therapy is usually combined with a humidification device, to prevent mucosal dryness. Depending on the cannula design, oxygen can be administered pre- or intra-nasally (administration of oxygen in front of the nasal ostia vs cannula system inside the nasal vestibulum). The impact of cannula design on intra-nasal humidity, however, has not been investigated to date. First, to develop a system, that samples air from the nasal cavity and analyzes the humidity of these samples. Second, to investigate nasal humidity during pre-nasal and intra-nasal oxygen application, with and without humidification. We first developed and validated a sampling and analysis system to measure humidity from air samples. By means of this system we measured inspiratory air samples from 12 subjects who received nasal oxygen with an intra-nasal and pre-nasal cannula at different flows, with and without humidification. The sampling and analysis system showed good correlation to a standard hygrometer within the tested humidity range (r = 0.99, P < .001). In our subjects intranasal humidity dropped significantly, from 40.3 ± 8.7% to 35.3 ± 5.8%, 32 ± 5.6%, and 29.0 ± 6.8% at flows of 1, 2, and 3 L, respectively, when oxygen was given intra-nasally without humidification (P = .001, P < .001, and P < .001, respectively). We observed no significant change in airway humidity when oxygen was given pre-nasally without humidification. With the addition of humidification we observed no significant change in humidity at any flow, and independent of pre- or intranasal oxygen administration. Pre-nasal administration of dry oxygen achieves levels of intranasal humidity similar to those achieved by intranasal administration in combination with a bubble through humidifier. Pre-nasal oxygen simplifies application and may reduce therapy cost.
Okuyama, Mayumi; Nishida, Masumi
2016-01-01
The aim of the present study was to examine the association between impending dehydration among elderly people in nursing homes and physical signs, including the axillary skin temperature, humidity, intraoral moisture content, and salivary components. The study included 78 elderly individuals who required long-term care in a nursing home (11 men and 67 women; average age, 86.6±7.3 years). The elderly subjects were classified in two groups according to their serum osmolality levels: those with levels between the upper limit reference value (292 mOsm/kg H2O) and the diagnostic reference value of dehydration (300 mOsm/kg H2O) were classified into the boundary zone group and those with levels of <292 mOsm/kg H2O were classified into the normal range group. The following parameters were measured: basic attributes (age, gender and level of care required), body mass index, diet, daily fluid intake per kilogram of body weight, physiological indicators (blood pressure, pulse rate, body temperature, axillary skin temperature, humidity, total body water, body water rate, internal liquid rate, external solution rate, blood components, intraoral water amount, and salivary components), and the indoor environment (room temperature and humidity). We then performed a statistical analysis to compare the boundary zone group with the normal range group. After adjusting for age and the daily fluid intake per kilogram of body weight (<25 ml/≥25 ml), we performed a logistic regression analysis (the boundary zone group was used as an independent variable) for variables that had significance levels of <0.05 (except for blood components). The univariate analysis revealed significant differences in the following parameters: the serum sodium, chloride, and creatinine levels; the blood sugar level; the urea nitrogen/creatinine ratio; the axillary skin temperature; and room humidity. Only the axillary skin temperature showed a significant association in the final model of the logistic regression analysis (odds ratio, 3.664; 95% confidence interval, 1.101-12.197; p = 0.034). As the axillary skin temperature increased by 1°C, there was a 3.67-fold risk of being classified into the boundary zone group instead of the normal range group. Thus, the axillary skin temperature was associated with impending dehydration.
Orejas, Jaime; Pfeuffer, Kevin P; Ray, Steven J; Pisonero, Jorge; Sanz-Medel, Alfredo; Hieftje, Gary M
2014-11-01
Ambient desorption/ionization (ADI) sources coupled to mass spectrometry (MS) offer outstanding analytical features: direct analysis of real samples without sample pretreatment, combined with the selectivity and sensitivity of MS. Since ADI sources typically work in the open atmosphere, ambient conditions can affect the desorption and ionization processes. Here, the effects of internal source parameters and ambient humidity on the ionization processes of the flowing atmospheric pressure afterglow (FAPA) source are investigated. The interaction of reagent ions with a range of analytes is studied in terms of sensitivity and based upon the processes that occur in the ionization reactions. The results show that internal parameters which lead to higher gas temperatures afforded higher sensitivities, although fragmentation is also affected. In the case of humidity, only extremely dry conditions led to higher sensitivities, while fragmentation remained unaffected.
NASA Astrophysics Data System (ADS)
Rieckh, Therese; Anthes, Richard; Randel, William; Ho, Shu-Peng; Foelsche, Ulrich
2018-05-01
While water vapor is the most important tropospheric greenhouse gas, it is also highly variable in both space and time, and water vapor concentrations range over 3 orders of magnitude in the troposphere. These properties challenge all observing systems to accurately measure and resolve the vertical structure and variability of tropospheric humidity. In this study we characterize the humidity measurements of various observing techniques, including four separate Global Positioning System (GPS) radio occultation (RO) humidity retrievals (University Corporation for Atmospheric Research (UCAR) direct, UCAR one-dimensional variational retrieval (1D-Var), Wegener Center for Climate and Global Change (WEGC) 1D-Var, Jet Propulsion Laboratory (JPL) direct), radiosonde, and Atmospheric Infrared Sounder (AIRS) data. Furthermore, we evaluate how well the ERA-Interim reanalysis and NCEP Global Forecast System (GFS) model perform in analyzing water vapor at different levels. To investigate detailed vertical structure, we analyzed time-height cross sections over four radiosonde stations in the tropical and subtropical western Pacific for the year 2007. We found that the accuracy of RO humidity is comparable to or better than both radiosonde and AIRS humidity over 800 to 400 hPa, as well as below 800 hPa if super-refraction is absent. The various RO retrievals of specific humidity agree within 20 % in the 1000-400 hPa layer, and differences are most pronounced above 600 hPa.
Model, Proxy and Isotopic Perspectives on the East African Humid Period
NASA Technical Reports Server (NTRS)
Tierney, Jessica E.; Lewis, Sophie C.; Cook, Benjamin I.; LeGrande, Allegra N.; Schmidt, Gavin A.
2011-01-01
Both North and East Africa experienced more humid conditions during the early and mid-Holocene epoch (11,000-5000yr BP; 11-5 ka) relative to today. The North African Humid Period has been a major focus of paleoclimatic study, and represents a response of the hydrological cycle to the increase in boreal summer insolation and associated ocean, atmosphere and land surface feedbacks. Meanwhile, the mechanisms that caused the coeval East African Humid Period are poorly understood. Here, we use results from isotopeenabled coupled climate modeling experiments to investigate the cause of the East African Humid Period. The modeling results are interpreted alongside proxy records of both water balance and the isotopic composition of rainfall. Our simulations show that the orbitally-induced increase in dry season precipitation and the subsequent reduction in precipitation seasonality can explain the East African Humid Period, and this scenario agrees well with regional lake level and pollen paleoclimate data. Changes in zonal moisture flux from both the Atlantic and Indian Ocean account for the simulated increase in precipitation from June through November. Isotopic paleoclimate data and simulated changes in moisture source demonstrate that the western East African Rift Valley in particular experienced more humid conditions due to the influx of Atlantic moisture and enhanced convergence along the Congo Air Boundary. Our study demonstrates that zonal changes in moisture advection are an important determinant of climate variability in the East African region.
Rathgeber, J; Züchner, K; Kietzmann, D; Weyland, W
1995-04-01
Heat and moisture exchangers (HME) are used as artificial noses for intubated patients to prevent tracheo-bronchial or pulmonary damage resulting from dry and cold inspired gases. HME are mounted directly on the tracheal tube, where they collect a large fraction of the heat and moisture of the expired air, adding this to the subsequent inspired breath. The effective performance depends on the water-retention capacity of the HME: the amount of water added to the inspired gas cannot exceed the stored water uptake of the previous breath. This study evaluates the efficiency of four different HME under laboratory and clinical conditions using a new moisture-measuring device. METHODS. In a first step, the absolute efficiency of four different HME (DAR Hygrobac, Gibeck Humid-Vent 2P, Pall BB 22-15 T, and Pall BB 100) was evaluated using a lung model simulating physiological heat and humidity conditions of the upper airways. The model was ventilated with tidal volumes of 500, 1,000, and 1,500 ml and different flow rates. The water content of the ventilated air was determined between tracheal tube and HME using a new high-resolution humidity meter and compared with the absolute water loss of the exhaled air at the gas outlet of a Siemens Servo C ventilator measured with a dew-point hygrometer. Secondly, the moisturizing efficiency was evaluated under clinical conditions in an intensive care unit with 25 intubated patients. Maintaining the ventilatory conditions for each patient, the HME were randomly changed. The humidity data were determined as described above and compared with the laboratory findings. RESULTS AND DISCUSSION. The water content at the respirator outlet is inversely equivalent to the humidity of the inspired gases and represents the water loss from the respiratory tract if the patient is ventilated with dry gases. Moisture retention and heating capacity decreased with higher volumes and higher flow rates. These data are simple to obtain without affecting the patient and can easily be interpreted. It was demonstrated that, compared to physiological conditions, the DAR Hygrobac and Gibeck Humid Vent 2P-HME coated with hygroscopic salts-were able to maintain sufficient inspiratory humidity and heat. The Pall-HME, solely a condensation humidifier, did not meet the physiological requirements.
Vermette, C J; Henrikson, Z A; Schwean-Lardner, K V; Crowe, T G
2017-09-01
The influence of hot conditions on 12-week-old turkey hens and 16-week-old toms while crated at transport density was evaluated. Forty-eight hens and 48 toms (8 birds per flock × 3 flocks × 2 humidity levels) were used in neutral treatments (trt; 20°C), and 16 hens and 16 toms (8 birds per flock × 1 flock × 2 humidity levels) were used in the hot trt (35°C). Birds were placed in crates at a transport stocking density of approximately 83 kg/m2, then inside a pre-conditioned chamber for 8 hours. Live shrink, core body temperature (CBT), heterophil/lymphocyte (H/L) ratio, and breast and thigh pH and color were recorded. Differences were declared significant at P ≤ 0.05. Live shrink after exposure to the 35°C trt (4.92%) was greater (P < 0.0001) than when birds were exposed to 20°C (1.48%). The 35°C trt (P < 0.0001) had higher Δ CBT (final minus initial) compared to the 20°C trt. The 35°C trt also caused higher (P < 0.0001) H/L ratio, 4.07 vs. 1.57 for the 20°C trt. Breast (P = 0.0110) and thigh pH levels (P < 0.0001) measured 27 h postmortem were lower for the 35°C trt at 5.64 and 5.73 compared to the 20°C trt at 5.70 and 5.92, respectively. Breast meat from birds exposed to 35°C was darker (P < 0.0001), while the color of thigh meat was unaffected. Toms quickly became distressed in the hot conditions, forcing those tests to be aborted. Only CBT data were analyzed. The CBT increased at a mean rate of 0.09°C/min for hens at both RH levels, while the CBT of toms increased at 0.12 and 0.18°C/min when exposed to 35°C, 30%; and 35°C, 80%, respectively. Exposure to hot temperatures caused higher CBT, greater live shrink, and greater H/L ratio. Toms were more greatly affected than hens to the hot trt, with CBT increasing at a greater rate. © 2017 Poultry Science Association Inc.
Analysis of Temperature and Humidity Field in a New Bulk Tobacco Curing Barn Based on CFD.
Bai, Zhipeng; Guo, Duoduo; Li, Shoucang; Hu, Yaohua
2017-01-31
A new structure bulk tobacco curing barn was presented. To study the temperature and humidity field in the new structure tobacco curing barn, a 3D transient computational fluid dynamics (CFD) model was developed using porous medium, species transport, κ-ε turbulence and discrete phase models. The CFD results demonstrated that (1) the temperature and relative humidity predictions were validated by the experimental results, and comparison of simulation results with experimental data showed a fairly close agreement; (2) the temperature of the bottom and inlet area was higher than the top and outlet area, and water vapor concentrated on the top and outlet area in the barn; (3) tobacco loading density and thickness of tobacco leaves had an explicit effect on the temperature distributions in the barn.
The course, stratification and possibility of simulating relative air humidity in winter wheat stand
NASA Astrophysics Data System (ADS)
Krčmářová, Jana; Pokorný, Radovan; Středa, Tomáš
2016-06-01
The aim of this study was: (i) long-term (2010, 2011 and 2013) evaluation of the relative air humidity in the winter wheat canopy, (ii) finding of relationships between relative air humidity in canopy and computed or measured meteorological values (precipitation totals, evapotranspiration, moisture balance, specific air humidity, volume soil moisture, % of available soil water content, value of soil water potential), (iii) testing of simulation of daily relative air humidity, based on selected meteorological values and potential evapotranspiration (FAO Penman-Monteith method) and actual evapotranspiration, (iv) testing of simulation of relative air humidity hourly values in the wheat canopy, (v) evaluation of dependence between relative air humidity and leaf wetness. The measurement was performed at the experimental field station of Mendel University in Žabčice (South Moravia, the Czech Republic). Data recording for wheat canopy was conducted by means of a meteostation equipped with digital air humidity and air temperature sensors positioned in the ground, effective height of the stand and in 2 m above the ground. The main vegetation period of wheat was divided into three stages to evaluate differences in various growing phases of wheat. The data from nearby standard climatological stations and from agrometeorological station in Žabčice were used for establishment of relationships between relative air humidity in winter wheat canopy and surrounding environment by correlation and regression analysis. Relative air humidity above 90% occurred substantially longer on the ground and at the effective height of the stand in comparison with the height of 2 m. By means of regression analysis we determined that the limit of 90% was reached in the canopy when at the climatological station it was just 60 to 90% for ground level and 70 to 90% for effective height, especially during the night. Slight dependence between measured or computed meteorological variables and relative air humidity in winter wheat canopy was found (r = 0.23 - 0.56 for precipitation totals, r = 0.27 - 0.57 for % of available soil water capacity, etc.). The simulation of hourly values of relative air humidity in wheat canopy is partially possible just when using the data of relative air humidity from the relevant standard climatological station.
Influence of Ambient Humidity on the Voltage Response of Ionic Polymer-Metal Composite Sensor.
Zhu, Zicai; Horiuchi, Tetsuya; Kruusamäe, Karl; Chang, Longfei; Asaka, Kinji
2016-03-31
Electrical potential based on ion migration exists not only in natural systems but also in ionic polymer materials. In order to investigate the influence of ambient humidity on voltage response, classical Au-Nafion IPMC was chosen as the reference sample. Voltage response under a bending deformation was measured in two ways: first, continuous measurement of voltage response in the process of absorption and desorption of water to study the tendency of voltage variation at all water states; second, measurements at multiple fixed ambient humidity levels to characterize the process of voltage response quantitatively. Ambient humidity influences the voltage response mainly by varying water content in ionic polymer. Under a step bending, the amplitude of initial voltage peak first increases and then decreases as the ambient humidity and the inherent water content decrease. This tendency is explained semiquantitatively by mass storage capacity related to the stretchable state of the Nafion polymer network. Following the initial peak, the voltage shows a slow decay to a steady state, which is first characterized in this paper. The relative voltage decay during the steady state always decreases as the ambient humidity is lowered. It is ascribed to progressive increase of the ratio between the water molecules in the cation hydration shell to the free water. Under sinusoidal mechanical bending excitation in the range of 0.1-10 Hz, the voltage magnitude increases with frequency at high ambient humidity but decreases with frequency at low ambient humidity. The relationship is mainly controlled by the voltage decay effect and the response speed.
NASA Astrophysics Data System (ADS)
Ostonen, I.; Kupper, P.; Sõber, J.; Aosaar, J.; Varik, M.; Lõhmus, K.
2012-04-01
A facility for free air humidity manipulation (FAHM) was established to investigate the effect of increased air humidity on belowground biomass and turnover in silver birch (Betula pendula Roth.) forest ecosystems with respect to rising air humidity predicted for Northern Europe. Fine root and rhizomes are short-lived and recognized as the most important component contributing to below-ground C fluxes in forests. The FAHM system enables air relative humidity to be increased on average 7 units (%) over the ambient level during mist fumigation. The experimental site contains humidified (H) and control (C) plots; each plot contains sectors with diverse "forest" understory and early successional grasses. The trees were planted in 2006, humidification started in spring 2008, and soil cores to study fine root and rhizome biomass and turnover were taken in 2007, 2009 and 2010. In July 2009, total fine root and rhizome biomass was 8 tons per ha in C and 16 tons per ha in H plots. The roots of understory formed 86% in C and 93% H plots, respectively. Our preliminary data suggest that the increased humidity affected more the roots of understory plants: fine root and rhizome biomass and production increased approximately twice by increasing air humidity. However, the tendency was similar for fine root biomass and production of silver birch. Fine root turnover speeded up for both silver birch and understory roots in H plots. Hence, changes in air humidity can significantly affect forest carbon cycling.
Tullus, Arvo; Kupper, Priit; Kaasik, Ants; Tullus, Hardi; Lõhmus, Krista; Sõber, Anu; Sellin, Arne
2017-05-01
The interactive effects of climate variables and tree-tree competition are still insufficiently understood drivers of forest response to global climate change. Precipitation and air humidity are predicted to rise concurrently at high latitudes of the Northern Hemisphere. We investigated whether the growth response of deciduous trees to elevated air humidity varies with their competitive status. The study was conducted in seed-originated silver birch and monoclonal hybrid aspen stands grown at the free air humidity manipulation (FAHM) experimental site in Estonia, in which manipulated stands (n = 3 for both species) are exposed to artificially elevated relative air humidity (6-7% over the ambient level). The study period included three growing seasons during which the stands had reached the competitive stage (trees were 7 years old in the final year). A significant 'treatment×competitive status' interactive effect on growth was detected in all years in birch (P < 0.01) and in one year in aspen stands (P = 0.015). Competitively advantaged trees were always more strongly affected by elevated humidity. Initially the growth of advantaged and neutral trees of both species remained significantly suppressed in humidified stands. In the following years, dominance and elevated humidity had a synergistic positive effect on the growth of birches. Aspens with different competitive status recovered more uniformly, attaining similar relative growth rates in manipulated and control stands, but preserved a significantly lower total growth yield due to severe initial growth stress. Disadvantaged trees of both species were never significantly affected by elevated humidity. Our results suggest that air humidity affects trees indirectly depending on their social status. Therefore, the response of northern temperate and boreal forests to a more humid climate in future will likely be modified by competitive relationships among trees, which may potentially affect species composition and cause a need to change forestry practices. © 2016 John Wiley & Sons Ltd.
Pelegrino, F S A; Pflugfelder, S C; De Paiva, C S
2012-01-01
Patients with tear dysfunction often experience increased irritation symptoms when subjected to drafty and/or low humidity environmental conditions. The purpose of this study was to investigate the effects of low humidity stress (LHS) on corneal barrier function and expression of cornified envelope (CE) precursor proteins in the epithelium of C57BL/6 and c-jun N-terminal kinase 2 (JNK2) knockout (KO) mice. LHS was induced in both strains by exposure to an air draft for 15 (LHS15D) or 30 days (LHS30D) at a relative humidity <30%RH. Nonstressed (NS) mice were used as controls. Oregon-green-dextran uptake was used to measure corneal barrier function. Levels of small proline-rich protein (SPRR)-2, involucrin, occludin, and MMP-9 were evaluated by immunofluorescent staining in cornea sections. Wholemount corneas immunostained for occludin were used to measure mean apical cell area. Gelatinase activity was evaluated by in situ zymography. Expression of MMP, CE and inflammatory cytokine genes was evaluated by qPCR. C57BL/6 mice exposed to LHS15D showed corneal barrier dysfunction, decreased apical corneal epithelial cell area, higher MMP-9 expression and gelatinase activity and increased involucrin and SPRR-2 immunoreactivity in the corneal epithelium compared to NS mice. JNK2KO mice were resistant to LHS-induced corneal barrier disruption. MMP-3,-9,-13, IL-1α, IL-1β, involucrin and SPRR-2a RNA transcripts were significantly increased in C57BL/6 mice at LHS15D, while no change was noted in JNK2KO mice. LHS is capable of altering corneal barrier function, promoting pathologic alteration of the TJ complex and stimulating production of CE proteins by the corneal epithelium. Activation of the JNK2 signaling pathway contributes to corneal epithelial barrier disruption in LHS. Copyright © 2011 Elsevier Ltd. All rights reserved.
Implications of drying temperature and humidity on the drying kinetics of seaweed
NASA Astrophysics Data System (ADS)
Ali, Majid Khan Majahar; Fudholi, Ahmad; Muthuvalu, M. S.; Sulaiman, Jumat; Yasir, Suhaimi Md
2017-11-01
A Low Temperature and Humidity Chamber Test tested in the Solar Energy Laboratory, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Selangor, Malaysia. Experiments are attempted to study the effect of drying air temperature and humidity on the drying kinetics of seaweed Kappaphycus species Striatum besides to develop a model to estimate the drying curves. Simple method using a excel software is used in the analysis of raw data obtained from the drying experiment. The values of the parameters a, n and the constant k for the models are determined using a plot of curve drying models. Three different drying models are compared with experiment data seaweed drying at 30, 40, 50 and 60°C and relative humidity 20, 30 and 40% for seaweed. The higher drying temperatures and low relative humidity effects the moisture content that will be rapidly reduced. The most suitable model is selected to best describe the drying behavior of seaweed. The values of the coefficient of determination (R2), mean bias error (MBE) and root mean square error (RMSE) are used to determine the goodness or the quality of the fit. The Page model is showed a better fit to drying seaweed. The results from this study crucial for solar dryer development on pilot scale in Malaysia.
Development of a Waterproof Crack-Based Stretchable Strain Sensor Based on PDMS Shielding.
Hong, Seong Kyung; Yang, Seongjin; Cho, Seong J; Jeon, Hyungkook; Lim, Geunbae
2018-04-12
This paper details the design of a poly(dimethylsiloxane) (PDMS)-shielded waterproof crack-based stretchable strain sensor, in which the electrical characteristics and sensing performance are not influenced by changes in humidity. This results in a higher number of potential applications for the sensor. A previously developed omni-purpose stretchable strain (OPSS) sensor was used as the basis for this work, which utilizes a metal cracking structure and provides a wide sensing range and high sensitivity. Changes in the conductivity of the OPSS sensor, based on humidity conditions, were investigated along with the potential possibility of using the design as a humidity sensor. However, to prevent conductivity variation, which can decrease the reliability and sensing ability of the OPSS sensor, PDMS was utilized as a shielding layer over the OPSS sensor. The PDMS-shielded OPSS sensor showed approximately the same electrical characteristics as previous designs, including in a high humidity environment, while maintaining its strain sensing capabilities. The developed sensor shows promise for use under high humidity conditions and in underwater applications. Therefore, considering its unique features and reliable sensing performance, the developed PDMS-shielded waterproof OPSS sensor has potential utility in a wide range of applications, such as motion monitoring, medical robotics and wearable healthcare devices.
C. R. Boardman; Samuel V. Glass; Charles G. Carll
2010-01-01
Proper management of indoor humidity in buildings is an essential aspect of durability. Following dissipation of moisture from construction materials, humidity levels during normal operation are generally assumed to primarily depend on the building volume, the number of building occupants and their behavior, the air exchange rate, and the water vapor content of outdoor...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, H.; Dean, J.; Privas, E.
2015-03-15
Nuclear plant operators (power generation, decommissioning and reprocessing operations) are required to monitor releases of tritium species for regulatory compliance and radiation protection purposes. Tritium monitoring is performed using tritium-in-air gas monitoring instrumentation based either on flow-through ion chambers or proportional counting systems. Tritium-in-air monitors are typically calibrated in dry conditions but in service may operate at elevated levels of relative humidity. The NPL (National Physical Laboratory) radioactive gas-in-air calibration system has been used to study the effect of humidity on the response to tritium of two tritium-in-air ion chamber based monitors and one proportional counting system which uses amore » P10/air gas mixture. The response of these instruments to HTO vapour has also been evaluated. In each case, instrument responses were obtained for HT in dry conditions (relative humidity (RH) about 2%), HT in 45% RH, and finally HTO at 45% RH. Instrumentation response to HT in humid conditions has been found to slightly exceed that in dry conditions. (authors)« less
How Dry is the Tropical Free Troposphere? Implications for Global Warming Theory
NASA Technical Reports Server (NTRS)
Spencer, Roy W.; Braswell, William D.
1997-01-01
The humidity of the free troposphere is being increasingly scrutinized in climate research due to its central role in global warming theory through positive water vapor feedback. This feedback is the primary source of global warming in general circulation models (GCMs). Because the loss of infrared energy to space increases nonlinearly with decreases in relative humidity, the vast dry zones in the Tropics are of particular interest. These dry zones are nearly devoid of radiosonde stations, and most of those stations have, until recently, ignored the low humidity information from the sondes. This results in substantial uncertainty in GCM tuning and validation based on sonde data. While satellite infrared radiometers are now beginning to reveal some information about the aridity of the tropical free troposphere, the authors show that the latest microwave humidity sounder data suggests even drier conditions than have been previously reported. This underscores the importance of understanding how these low humidity levels are controlled in order to tune and validate GCMs, and to predict the magnitude of water vapor feedback and thus the magnitude of global warming.
Lee, Pil Hyong; Hwang, Sang Soon
2009-01-01
In fuel cells flow configuration and operating conditions such as cell temperature, humidity at each electrode and stoichiometric number are very crucial for improving performance. Too many flow channels could enhance the performance but result in high parasite loss. Therefore a trade-off between pressure drop and efficiency of a fuel cell should be considered for optimum design. This work focused on numerical simulation of the effects of operating conditions, especially cathode humidity, with simple micro parallel flow channels. It is known that the humidity at the cathode flow channel becomes very important for enhancing the ion conductivity of polymer membrane because fully humidified condition was normally set at anode. To investigate the effect of humidity on the performance of a fuel cell, in this study humidification was set to 100% at the anode flow channel and was changed by 0–100% at the cathode flow channel. Results showed that the maximum power density could be obtained under 60% humidified condition at the cathode where oxygen concentration was moderately high while maintaining high ion conductivity at a membrane. PMID:22291556
Lee, Pil Hyong; Hwang, Sang Soon
2009-01-01
In fuel cells flow configuration and operating conditions such as cell temperature, humidity at each electrode and stoichiometric number are very crucial for improving performance. Too many flow channels could enhance the performance but result in high parasite loss. Therefore a trade-off between pressure drop and efficiency of a fuel cell should be considered for optimum design. This work focused on numerical simulation of the effects of operating conditions, especially cathode humidity, with simple micro parallel flow channels. It is known that the humidity at the cathode flow channel becomes very important for enhancing the ion conductivity of polymer membrane because fully humidified condition was normally set at anode. To investigate the effect of humidity on the performance of a fuel cell, in this study humidification was set to 100% at the anode flow channel and was changed by 0-100% at the cathode flow channel. Results showed that the maximum power density could be obtained under 60% humidified condition at the cathode where oxygen concentration was moderately high while maintaining high ion conductivity at a membrane.
Improved protocol and data analysis for accelerated shelf-life estimation of solid dosage forms.
Waterman, Kenneth C; Carella, Anthony J; Gumkowski, Michael J; Lukulay, Patrick; MacDonald, Bruce C; Roy, Michael C; Shamblin, Sheri L
2007-04-01
To propose and test a new accelerated aging protocol for solid-state, small molecule pharmaceuticals which provides faster predictions for drug substance and drug product shelf-life. The concept of an isoconversion paradigm, where times in different temperature and humidity-controlled stability chambers are set to provide a critical degradant level, is introduced for solid-state pharmaceuticals. Reliable estimates for temperature and relative humidity effects are handled using a humidity-corrected Arrhenius equation, where temperature and relative humidity are assumed to be orthogonal. Imprecision is incorporated into a Monte-Carlo simulation to propagate the variations inherent in the experiment. In early development phases, greater imprecision in predictions is tolerated to allow faster screening with reduced sampling. Early development data are then used to design appropriate test conditions for more reliable later stability estimations. Examples are reported showing that predicted shelf-life values for lower temperatures and different relative humidities are consistent with the measured shelf-life values at those conditions. The new protocols and analyses provide accurate and precise shelf-life estimations in a reduced time from current state of the art.
Pang, Xiaobing
2015-06-01
Green leaf volatiles (GLVs) emitted by plants after stress or damage induction are a major part of biogenic volatile organic compounds (BVOCs). Proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) is a high-resolution and sensitive technique for in situ GLV analyses, while its performance is dramatically influenced by humidity, electric field, etc. In this study the influence of gas humidity and the effect of reduced field (E/N) were examined in addition to measuring calibration curves for the GLVs. Calibration curves measured for seven of the GLVs in dry air were linear, with sensitivities ranging from 5 to 10 ncps/ppbv (normalized counts per second/parts per billion by volume). The sensitivities for most GLV analyses were found to increase by between 20% and 35% when the humidity of the sample gas was raised from 0% to 70% relative humidity (RH) at 21°C, with the exception of (E)-2-hexenol. Product ion branching ratios were also affected by humidity, with the relative abundance of the protonated molecular ions and higher mass fragment ions increasing with humidity. The effect of reduced field (E/N) on the fragmentation of GLVs was examined in the drift tube of the PTR-TOF-MS. The structurally similar GLVs are acutely susceptible to fragmentation following ionization and the fragmentation patterns are highly dependent on E/N. Overall the measured fragmentation patterns contain sufficient information to permit at least partial separation and identification of the isomeric GLVs by looking at differences in their fragmentation patterns at high and low E/N. Copyright © 2015. Published by Elsevier B.V.
Wang, Juan; Li, Baizhan; Yang, Qin; Yu, Wei; Wang, Han; Norback, Dan; Sundell, Jan
2013-01-01
The prevalence of perceptions of odors and sensations of air humidity and sick building syndrome symptoms in domestic environments were studied using responses to a questionnaire on the home environment. Parents of 4530 1–8 year old children from randomly selected kindergartens in Chongqing, China participated. Stuffy odor, unpleasant odor, pungent odor, mold odor, tobacco smoke odor, humid air and dry air in the last three month (weekly or sometimes) was reported by 31.4%, 26.5%, 16.1%, 10.6%, 33.0%, 32.1% and 37.2% of the parents, respectively. The prevalence of parents’ SBS symptoms (weekly or sometimes) were: 78.7% for general symptoms, 74.3% for mucosal symptoms and 47.5% for skin symptoms. Multi-nominal regression analyses for associations between odors/sensations of air humidity and SBS symptoms showed that the odds ratio for “weekly” SBS symptoms were consistently higher than for “sometimes” SBS symptoms. Living near a main road or highway, redecoration, and new furniture were risk factors for perceptions of odors and sensations of humid air and dry air. Dampness related problems (mold spots, damp stains, water damage and condensation) were all risk factors for perceptions of odors and sensations of humid air and dry air, as was the presence of cockroaches, rats, and mosquitoes/flies, use of mosquito-repellent incense and incense. Protective factors included cleaning the child’s bedroom every day and frequently exposing bedding to sunshine. In conclusion, adults’ perceptions of odors and sensations of humid air and dry air are related to factors of the home environment and SBS symptoms are related to odor perceptions. PMID:23991107
Rezvan, K; Dabidi Roshan, V; Mahmudi, S A
2015-11-01
Asthmatic obese children experience changes in functional capacity and autonomic control. Previous heart rate variability (HRV) studies were based on 24-hour recordings, little research has been conducted on the short-term HRV in asthmatic obese children, primarily during physical effort indifferent environmental humidity conditions. The aim of this study was to evaluate the effect of aerobic activity on short-term HRV in asthmatic obese children under two different environmental humidity conditions. Ten obese boys with mild asthma as experimental group and 15 obese healthy boys with the same conditions were involved as a control group. Protocol included progressive and exhaustive aerobic activities on a calibrated ergometer pedal bicycle in two various environmental humidity 35±5% and 65±5%. HRV was measured by PADSY MEDSET Holter monitoring device during three phases; pre-test, mid-test and post-test. Then, short-term HRV was assessed from calculation of the mean R-R interval measured on HRV at each phases. HRV significantly decreased at mid-test and post-test among asthmatic and health children. However, the aforesaid changes were significantly higher in the asthmatic than health children following. Moreover, decrease of short-term HRV was significantly greater in the 35±5% than 65±5% environmental humidity. Our findings suggest from the autonomic standpoint, asthmatic and non-asthmatic children respond differently to exhaustive exercise induced stress. Aerobic exercise at an environment with high humidity compared with the low humidity appears to have additional benefits on short-term HRV in that it enhances the parasympathetic and autonomic modulation of the heart in asthmatic obese children.
Bowler, Michael G; Bowler, David R; Bowler, Matthew W
2017-04-01
The humidity surrounding a sample is an important variable in scientific experiments. Biological samples in particular require not just a humid atmosphere but often a relative humidity (RH) that is in equilibrium with a stabilizing solution required to maintain the sample in the same state during measurements. The controlled dehydration of macromolecular crystals can lead to significant increases in crystal order, leading to higher diffraction quality. Devices that can accurately control the humidity surrounding crystals while monitoring diffraction have led to this technique being increasingly adopted, as the experiments become easier and more reproducible. Matching the RH to the mother liquor is the first step in allowing the stable mounting of a crystal. In previous work [Wheeler, Russi, Bowler & Bowler (2012). Acta Cryst. F 68 , 111-114], the equilibrium RHs were measured for a range of concentrations of the most commonly used precipitants in macromolecular crystallography and it was shown how these related to Raoult's law for the equilibrium vapour pressure of water above a solution. However, a discrepancy between the measured values and those predicted by theory could not be explained. Here, a more precise humidity control device has been used to determine equilibrium RH points. The new results are in agreement with Raoult's law. A simple argument in statistical mechanics is also presented, demonstrating that the equilibrium vapour pressure of a solvent is proportional to its mole fraction in an ideal solution: Raoult's law. The same argument can be extended to the case where the solvent and solute molecules are of different sizes, as is the case with polymers. The results provide a framework for the correct maintenance of the RH surrounding a sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oberson, Greg; Dunn, Darrell; Mintz, Todd
2013-07-01
At a number of locations in the U.S., spent nuclear fuel (SNF) is maintained at independent spent fuel storage installations (ISFSIs). These ISFSIs, which include operating and decommissioned reactor sites, Department of Energy facilities in Idaho, and others, are licensed by the U.S. Nuclear Regulatory Commission (NRC) under Title 10 of the Code of Federal Regulations, Part 72. The SNF is stored in dry cask storage systems, which most commonly consist of a welded austenitic stainless steel canister within a larger concrete vault or overpack vented to the external atmosphere to allow airflow for cooling. Some ISFSIs are located inmore » marine environments where there may be high concentrations of airborne chloride salts. If salts were to deposit on the canisters via the external vents, a chloride-rich brine could form by deliquescence. Austenitic stainless steels are susceptible to chloride-induced stress corrosion cracking (SCC), particularly in the presence of residual tensile stresses from welding or other fabrication processes. SCC could allow helium to leak out of a canister if the wall is breached or otherwise compromise its structural integrity. There is currently limited understanding of the conditions that will affect the SCC susceptibility of austenitic stainless steel exposed to marine salts. NRC previously conducted a scoping study of this phenomenon, reported in NUREG/CR-7030 in 2010. Given apparent conservatisms and limitations in this study, NRC has sponsored a follow-on research program to more systematically investigate various factors that may affect SCC including temperature, humidity, salt concentration, and stress level. The activities within this research program include: (1) measurement of relative humidity (RH) for deliquescence of sea salt, (2) SCC testing within the range of natural absolute humidity, (3) SCC testing at elevated temperatures, (4) SCC testing at high humidity conditions, and (5) SCC testing with various applied stresses. Results to date indicate that the deliquescence RH for sea salt is close to that of MgCl{sub 2} pure salt. SCC is observed between 35 and 80 deg. C when the ambient (RH) is close to or higher than this level, even for a low surface salt concentration. (authors)« less
A Study of the Physical Processes of an Advection Fog BoundaryLayer
NASA Astrophysics Data System (ADS)
Liu, D.; Yan, W.; Kang, Z.; Dai, Z.; Liu, D.; Liu, M.; Cao, L.; Chen, H.
2016-12-01
Using the fog boundary layer observation collected by a moored balloon between December 1 and 2, 2009, the processes of advection fog formation and dissipation under cold and warm double-advection conditions was studied. the conclusions are as follows: 1. The advection fog process was generated by the interaction between the near-surface northeast cold advection and the upper layer's southeast warm, humid advection. The ground fog formed in an advection cooling process, and the thick fog disappeared in two hours when the wind shifted from the northeast to the northwest. The top of the fog layer remained over 600 m for most of the time. 2. This advection fog featured a double-inversion structure. The interaction between the southeast warm, humid advection of the upper layer and the descending current generated the upper inversion layer. The northeast cold advection near the ground and the warm, humid advection in the high-altitude layer formed the lower layer clouds and lower inversion layer. The upper inversion layer was composed of southeast warm, humid advection and a descending current with increasing temperature. The double inversion provided good thermal conditions for maintaining the thick fog layer. 3. The southeast wind of the upper layer not only created the upper inversion layer but also brought vapour-rich air to the fog region. The steady southeast vapour transportation by the southeast wind was the main condition that maintained the fog thickness, homogeneous density, and long duration. The low-altitude low-level jet beneath the lower inversion layer helped maintain the thickness and uniform density of the fog layer by enhancing the exchange of heat, momentum and vapour within the lower inversion layer. 4. There were three transportation mechanisms associated with this advection fog: 1) The surface layer vapour was delivered to the lower fog layer. 2) The low-altitude southeast low-level jet transported the vapour to the upper layer. 3) The vapour was exchanged between the upper and lower layers via the turbulent exchange and vertical air motion, which mixed the fog density and maintained the thickness of the fog. These mechanisms explain why the fog top was higher than the lower inversion layer and reached the upper inversion layer, as well as why this advection fog was so thick.
NASA Astrophysics Data System (ADS)
Araújo, E. S.; Libardi, J.; Faia, P. M.; de Oliveira, H. P.
2018-02-01
Metal oxide composites have attracted much consideration due to their promising applications in humidity sensors in response to the physical and chemical property modifications of the resulting materials. This work focused on the preparation, microstructural characterization and analysis of humidity-dependent electrical properties of undoped and vanadium oxide (V2O5)-doped titanium oxide/tungsten oxide (TiO2/WO3) sintered ceramic films obtained by electrospinning. The electrical properties were investigated by impedance spectroscopy (400 Hz-40 MHz) as a function of relative humidity (RH). The results revealed a typical transition in the transport mechanisms controlled by the appropriated doping level of V2O5, which introduces important advantages to RH detection due to the atomic substitution of titanium by vanadium atoms in highly doped structures. These aspects are directly related to the microstructure modification and structure fabrication procedure.
Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, Jr., Charles R.
2016-12-01
In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split onmore » seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-01-01
In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split onmore » seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.« less
Humidity Data for 9975 Shipping Packages with Softwood Fiberboard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
The 9975 surveillance program is developing a technical basis to support extending the storage period of 9975 packages in K-Area Complex beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Direct measurements of humidity and fiberboard moisture content have been made on two test packages with softwood fiberboard and varying internal heat levels from 0 up to 19W. Comparable measurements withmore » cane fiberboard have been reported previously. With an internal heat load, a temperature gradient in the fiberboard assembly leads to varying relative humidity in the air around the fiberboard. However, the absolute humidity tends to remain approximately constant throughout the package, especially at lower heat loads.« less
Danielsen, Charlotte; Hansen, Lise Stengård; Nachman, Gösta; Herling, Christian
2004-01-01
Laboratory experiments with Lepidoglyphus destructor on a diet of mainly whole wheat were conducted to study the mite's development and production of a specific allergen, Lep d 2, at four different temperatures (5, 10, 15 and 20 degrees C) and three levels of relative humidity (ca. 70-88%). Statistical models were used to analyse the role played by temperature, relative humidity and time in explaining the observed number of L. destructor and the amount of allergen produced. Moreover, the life stage distributions of the mites were determined and related to the population growth. Based on a statistical model the intrinsic rate of natural increase, rm, was computed for a range of different temperatures and relative humidities. High relative humidity in combination with temperatures at about 25 degrees C will lead to the highest rm (ca. 0.15 day-1). The highest concentration of Lep d 2 was 3 micrograms g-1 grain, found at 20 degrees C and high relative humidity at a mite density of 254 mites g-1 grain. The concentration of allergens in the grain was best explained by a model that incorporated both the current and the cumulative numbers of mites.
Al-Ta’ii, Hassan Maktuff Jaber; Amin, Yusoff Mohd; Periasamy, Vengadesh
2016-01-01
Deoxyribonucleic acid or DNA based sensors, especially as humidity and alpha particle sensors have become quite popular in recent times due to flexible and highly optimizable nature of this fundamental biomaterial. Application of DNA electronics allow for more sensitive, accurate and effective sensors to be developed and fabricated. In this work, we examined the effect of different humidity conditions on the capacitive and resistive response of Aluminum (Al)/DNA/Al Schottky barrier structure when bombarded by time-dependent dosages of alpha particles. Based on current-voltage profiles, which demonstrated rectifying behaviours, Schottky diode parameters such as ideality factor, barrier height and series resistance was calculated. Results observed generally pointed towards a decrease in the resistance value from the pristine to the radiated structures. It was also demonstrated that under the effect of humidity, the capacitance of the DNA thin film increased from 0.05894 to 92.736 nF, with rising relative humidity level. We also observed the occurrence of the hypersensitivity phenomena after alpha irradiation between 2 to 4 min by observing a drop in the series resistance, crucial in the study of DNA damage and repair mechanisms. These observations may also suggest the exciting possibility of utilizing Al/DNA/Al Schottky diodes as potentially sensitive humidity sensors. PMID:27160654
Comparison of land surface humidity between observations and CMIP5 models
NASA Astrophysics Data System (ADS)
Dunn, Robert J. H.; Willett, Kate M.; Ciavarella, Andrew; Stott, Peter A.
2017-08-01
We compare the latest observational land surface humidity dataset, HadISDH, with the latest generation of climate models extracted from the CMIP5 archive and the ERA-Interim reanalysis over the period 1973 to present. The globally averaged behaviour of HadISDH and ERA-Interim are very similar in both humidity measures and air temperature, on decadal and interannual timescales. The global average relative humidity shows a gradual increase from 1973 to 2000, followed by a steep decline in recent years. The observed specific humidity shows a steady increase in the global average during the early period but in the later period it remains approximately constant. None of the CMIP5 models or experiments capture the observed behaviour of the relative or specific humidity over the entire study period. When using an atmosphere-only model, driven by observed sea surface temperatures and radiative forcing changes, the behaviour of regional average temperature and specific humidity are better captured, but there is little improvement in the relative humidity. Comparing the observed climatologies with those from historical model runs shows that the models are generally cooler everywhere, are drier and less saturated in the tropics and extra-tropics, and have comparable moisture levels but are more saturated in the high latitudes. The spatial pattern of linear trends is relatively similar between the models and HadISDH for temperature and specific humidity, but there are large differences for relative humidity, with less moistening shown in the models over the tropics and very little at high latitudes. The observed drying in mid-latitudes is present at a much lower magnitude in the CMIP5 models. Relationships between temperature and humidity anomalies (T-q and T-rh) show good agreement for specific humidity between models and observations, and between the models themselves, but much poorer for relative humidity. The T-q correlation from the models is more steeply positive than the observations in all regions, and this over-correlation may be due to missing processes in the models. The observed temporal behaviour appears to be a robust climate feature rather than observational error. It has been previously documented and is theoretically consistent with faster warming rates over land compared to oceans. Thus, the poor replication in the models, especially in the atmosphere-only model, leads to questions over future projections of impacts related to changes in surface relative humidity. It also precludes any formal detection and attribution assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, Danny S.; Cummings, Jamie E.; Vieira, Robin K.
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, Søren Thor, E-mail: stl@nrcwe.dk; Wolkoff, Peder, E-mail: pwo@nrcwe.dk; Hammer, Maria, E-mail: mha@nrcwe.dk
We investigated the role of air humidity and allergic sensitization on the acute airway response to inhaled formaldehyde (FA) vapor. Mice were sensitized to the immunogen ovalbumin (OVA) by three intraperitoneal injections followed by two aerosol challenges, giving rise to allergic airway inflammation. Control mice were sham sensitized by saline injections and challenged by saline aerosols. Once sensitized, the mice were housed at high (85–89%) or low (< 10%) relative humidity, respectively for 48 h prior to a 60-min exposure to either 0.4, 1.8 or about 5 ppm FA. Before, during and after exposure, breathing parameters were monitored. These includedmore » the specific markers of nose and lung irritations as well as the expiratory flow rate, the latter being a marker of airflow limitation. The sensory irritation response in the upper airways was not affected by allergic inflammation or changes in humidity. At high relative humidity, the OVA-sensitized mice had a decreased expiratory airflow rate compared to the saline control mice after exposure to approximately 5 ppm FA. This is in accordance with the observations that asthmatics are more sensitive than non-asthmatics to higher concentrations of airway irritants including FA. In the dry environment, the opposite trend was seen; here, the saline control mice had a significantly decreased expiratory airflow rate compared to OVA-sensitized mice when exposed to 1.8 and 4 ppm FA. We speculate that increased mucus production in the OVA-sensitized mice has increased the “scrubber effect” in the nose, consequently protecting the conducting and lower airways. - Highlights: ► Role of air humidity and allergy on sensitivity to an airway irritant was studied. ► In the humid environment, allergy amplified the effects of formaldehyde. ► In the dry environment, allergy reduced the effect of formaldehyde. ► Neither allergy nor humidity changed the formaldehyde-induced nasal irritation.« less
How Ambient Humidity May Affect the Transmission of Viral Infectious Diseases
NASA Astrophysics Data System (ADS)
Yang, Wan; Marr, Linsey; Elankumaran, Subbiah
2013-04-01
Viral infectious diseases such as influenza have been a great burden to public health. The airborne transmission route is an important venue for the spread of many respiratory viral diseases. Many airborne viruses have been shown to be sensitive to ambient humidity, yet the mechanisms responsible for this phenomenon remain elusive. A thorough understanding of this phenomenon may provide insight into the temporal and spatial distribution of diseases. For instance, studies have repeatedly suggested ambient humidity as an important environmental determinant in the transmission of influenza in temperate regions. Further, knowing how to optimize humidity so as to minimize virus survival may have practical implications for disease prevention. In this talk, we will discuss multiple mechanisms that may account for the association between humidity and viability of viruses in aerosols, including water activity, surface inactivation, salt toxicity, and conformational changes to the virus in response to varying pH. As a case study, we will discuss our work on the effect of relative humidity (RH) on survival of influenza A virus (IAV) and how it may contribute to the transmission patterns of seasonal flu around the world. We measured the change in viability of IAV in droplets at various RHs. Results suggest three potential regimes defined by humidity: physiological (~100% RH) with high viability, concentrated (~50% to near 100% RH) with lower viability, and dry (<~50% RH) with high viability. Based on these results, we propose a mechanistic basis for the dependence of IAV's transmission on humidity. In temperate regions, the increase in influenza activity in winter may be due to enhanced transmission via the aerosol route thanks to IAV's higher viability in droplets at low RH. In tropical regions, transmission could be enhanced due to high viability of IAV at extremely high RH (rainy season), as observed in our study, possibly through both the aerosol route and the contact route.
NASA Astrophysics Data System (ADS)
Serpa, Dalila; Nunes, João Pedro; Santos, Juliana; Sampaio, Elsa; Jacinto, Rita; Veiga, Sandro; Lima, Júlio; Moreira, Madalena; Corte-Real, João; Keizer, Jan Jacob; Abrantes, Nelson
2016-04-01
The impacts of climate and land use changes on streamflow and sediment export were evaluated for a humid (São Lourenço) and a dry (Guadalupe) Mediterranean catchment, using the Soil and Water Assessment Tool (SWAT) model. SWAT was able to produce viable streamflow and sediment export simulations for both catchments, which provided a baseline for investigating climate and land use changes under the A1B and B1 emission scenarios for the period between 2071 and 2100. Compared to the baseline period (1971-2000), climate change scenarios forecasted a decrease in annual precipitation in both catchments (humid, both scenarios: -12%; dry, both scenarios: -8%), but with strong increases during winter. Land use changes followed a socio-economic storyline in which traditional agriculture was replaced by more profitable land uses, i.e. corn and commercial forestry at the humid site and sunflower at the dry site. Climate changes led to a decrease of streamflow in both catchments (humid, both scenarios: -13%; dry, A1B: -14%; B1: -18%), mostly as a consequence of the projected decrease in rainfall. Land use changes led to small increases in flow discharge, but a higher increase was observed for the dry site under scenario A1B (humid, A1B: +0.3%; B1: +1%; dry, A1B: +6%; B1: +0.3%). The combination of climate and land use scenarios was mostly dominated by the climatic response, since a decrease in streamflow was observed for both catchments (humid, A1B: -13%; B1: -12%; dry, A1B: -8%; B1: -18%). Regarding the erosive response, clear differences were observed between catchments mostly due to differences in both the present-day and forecasted vegetation types. Climate scenarios led to a decrease in sediment export at the humid catchment (A1B: -11%; B1: -9%) and to an increase at the dry catchment (A1B: +24%; B1: +22%) in the first case due to the predominant vegetation type (vineyards and maritime pine) providing year-round cover, while in the second, due to annual crops (wheat and pasture) exposing soils during winter. For land use scenarios, the same contrast occurred between catchments (humid, A1B: -18%; B1: -10%; dry, A1B: +257%; B1: +9%) due to the expansion of permanent cover vegetation in one case and annual crops in the other. Climate and land use changes had off-setting effects on sediment export at the humid catchment (A1B: -29%; B1: -22%), as a result of reduced precipitation and cultivation of more soil-protective crops. A different response was observed for the dry catchment (A1B: +222%; B1: +5%), as the increase in sediment export associated with the cultivation of highly erosion-prone crops was not aggravated by the higher rainfall amounts forecasted for winter months. The results of the present study highlight that indirect impacts of climate change, like land use changes, might be similar or more severe than direct impacts.
Dubina, E; Korat, L; Black, L; Strupi-Šuput, J; Plank, J
2013-07-01
Micro-Raman spectroscopy has been used to follow the reaction of free lime (CaO) exposed for 24h to moist air at 80 °C under conditions of different relative humidities (10-80% RH). X-ray diffraction and SEM imaging were applied as complementary techniques. The conversion of lime to calcium hydroxide and its subsequent carbonation to various calcium carbonate polymorphs was found to strongly depend on the relative humidity. At low RH (10-20%), only Raman spectroscopy revealed the formation of early amorphous CaCO3 which in the XRD patterns was detected only at ≥40% RH. However, XRD analysis could identify the crystalline polymorphs formed at higher relative humidities. Thus, between 20 and 60% RH, all three CaCO3 polymorphs (calcite, aragonite and vaterite) were observed via XRD whereas at high relative humidity (80%), calcite was the predominant reaction product. The results demonstrate the usefulness of Raman spectroscopy in the study of minor cement constituents and their reaction products on air, especially of amorphous character. Copyright © 2013 Elsevier B.V. All rights reserved.
Implications of Enhanced Relative Humidity in Cold Tropical Cirrus
NASA Technical Reports Server (NTRS)
Jensen, Eric; Pfister, Leonhard
2004-01-01
In situ measurements of water vapor concentration and temperature in tropical cirrus during the CRYSTAL-FACE and Pre-AVE missions indicate that the steady-state relative humidity within cirrus at T less than 200 K is about 20-30% higher than ice saturation. These measurements challenge the conventional belief, that any water vapor in excess of ice saturation should be depleted by crystal growth given sufficient time. Detailed simulations of thin cirrus near the tropopause indicate that this enhanced steady-state relative humidity increases ice number densities, decreases crystal sizes and extends cloud lifetimes. The areal coverage of thin cirrus in the tropics is increased rather than decreased as indicated by simpler conceptual models. Perhaps most significantly, the increased steady-state H2O saturation mixing ratio over ice in thin cirrus near the tropopause results in about a 0.5-1 ppmv increase in the amount of water that can enter the stratosphere across the tropical tropopause cold trap. Hence, the enhanced steady-state relative humidity in cold cirrus implies that lower tropopause temperatures are required to explain the observed stratospheric water vapor mixing ratios than previously assumed.
Gas Engine-Driven Heat Pump with Desiccant Dehumidification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Abu-Heiba, Ahmad
About 40% of total U.S. energy consumption was consumed in residential and commercial buildings. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. This paper describes the development of an innovative natural gas, propane, LNG or bio-gas IC engine-driven heat pump (GHP) with desiccant dehumidification (GHP/DD). This integrated system has higher overall efficiencies than conventional equipment for space cooling, addresses both new and existing commercial buildings, and more effectively controls humidity in humid areas. Waste heat is recovered from the GHP to provide energy for regenerating themore » desiccant wheel and to augment heating capacity and efficiency. By combining the two technologies, an overall source COP of greater that 1.5 (hot, humid case) can be achieved by utilizing waste heat from the engine to reduce the overall energy required to regenerate the desiccant. Moreover, system modeling results show that the sensible heat ratio (SHR- sensible heat ratio) can be lowered to less 60% in a dedicated outdoor air system application with hot, humid cases.« less
Yang, Xiaojuan; Thornton, Peter E.; Ricciuto, Daniel M.; ...
2016-07-14
The effects of phosphorus (P) availability on carbon (C) cycling in the Amazon region are investigated using CLM-CNP. Within this paper, we demonstrate that the coupling of P dynamics reduces the simulated historical terrestrial C sink due to increasing atmospheric CO 2 concentrations ([CO 2]) by about 26%. Our exploratory simulations show that the response of tropical forest C cycling to increasing [CO 2] depends on how elevated CO 2 affects phosphatase enzyme production. The effects of warming are more complex, depending on the interactions between humidity, C, and nutrient dynamics. While a simulation with low humidity generally shows themore » reduction of net primary productivity (NPP), a second simulation with higher humidity suggests overall increases in NPP due to the dominant effects of reduced water stress and more nutrient availability. Lastly, our simulations point to the need for (1) new observations on how elevated [CO 2] affects phosphatase enzyme production and (2) more tropical leaf-scale measurements under different temperature/humidity conditions with different soil P availability.« less
Photoconductivity in DNA-Porphyrin Complexes
NASA Astrophysics Data System (ADS)
Myint, Peco; Oxford, Emma; Nyazenga, Collence; Smith, Walter; Qi, Zhengqing; Johnson, A. T.
2015-03-01
We have measured the photoconductivity of λ - DNA that is modified by intercalating a porphyrin compound, meso-tetrakis(N-methyl-4-pyridiniumyl)porphyrin (TMPyP), into its base stacks. Intercalation was verified by a red shift and hypochromism of the Soret absorption peak. The DNA/porphyrin strands were then deposited onto oxidized silicon substrates which had been patterned with interdigitated electrodes, and blown dry. Electrical measurements were carried out under nitrogen, using illumination from a 445 nm laser; this wavelength falls within the absorption peak of the DNA/porphyrin complexes. When initially measured under dry nitrogen, the complexes show no photoconductivity or dark conductivity. However, at relative humidities of 30% and above, we do observe dark conductivity, and also photoconductivity that grows with time. Photoconductivity gets larger at higher relative humidity. Remarkably, when the humidity is lowered again, some photoconductivity is now observed, indicating a change that persists for more than 24 hours. It may be that the humidity alters the structure of the DNA, perhaps allowing for better alignment of the bases. This work was supported by NSF Grant BMAT-1306170.
Effect of air temperature and humidity on ingestive behaviour of sheep
NASA Astrophysics Data System (ADS)
Paranhos da Costa, Mateus J. R.; da Silva, Roberto Gomes; de Souza, Roberto Carlos
1992-12-01
Thirty-two Polwarth ewes, of ages up to 1 year, were observed in a climatic chamber (24 to 45° C) for eight periods of 5 h each. The observations were made through a window in the chamber wall. All animals were observed four times, then shorn and observed four times again. The animals were given weighed quantities of water and feed consisting of commercial concentrate plus Rhodes grass ( Chloris gayana) hay. The water and feed remaining after 5 h of observation were weighed. The following traits were analysed: time eating hay (TEH), time eating concentrate (TEC), time drinking water (TDW), weight of hay eaten (WHE), weight of concentrate eaten (WCE), volume of ingested water (VIW), ruminating time standing up (RTS), ruminating time lying down (RTL), idling time standing up (ITS), and idling time lying down (ITL). Shearing had a significant effect for all traits except ITS. Shearing resulted in higher values for all traits except for ITS and ITL. Ingestion of hay (TEH and WHE) decreased with increased air temperature and humidity, while the ingestion of concentrate (TEC) and WHE) and water (TDW and VIW) increased. Rumination decreased with increased air temperature and humidity, and was higher in shorn than in unshorn sheep.
Effect of temperature and humidity on formaldehyde emissions in temporary housing units.
Parthasarathy, Srinandini; Maddalena, Randy L; Russell, Marion L; Apte, Michael G
2011-06-01
The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S. Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. On the basis of a previous study, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high-performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using the natural log of the percent relative humidity (RH) and inverse of temperature (in K) as independent variables and the natural log of emission factors as the dependent variable. The coefficients for the inverse of temperature and log RH with log emission factor were found to be statistically significant for all of the samples at the 95% confidence level. This study should assist in retrospectively estimating indoor formaldehyde exposure of occupants of THUs.
NASA Astrophysics Data System (ADS)
Coughlan, Neil E.; Kelly, Tom C.; Davenport, John; Jansen, Marcel A. K.
2015-05-01
Birds as carriers of propagules are major agents in the dispersal of plants, animals, fungi and microbes. However, there is a lack of empirical data in relation to bird-mediated, epizoochorous dispersal. The microclimate found within the plumage likely plays a pivotal role in survival during flight conditions. To investigate the potential of epizoochory, we have analysed the microclimatic conditions within the plumage of mallard ducks (Anas platyrhynchos). Under similar ambient conditions of humidity and temperature, a sample of mallards showed a consistent microclimatic regime with variation across the body surface. The highest (mean) temperature and specific humidity occurred between feathers of the postpatagium. The lowest humidity was found between feathers of the centre back and the lowest temperature in the crissum. Observed differences in plumage depth and density, and distance from the skin, are all likely to be determining factors of microclimate condition. Specific humidity found within the plumage was on average 1.8-3.5 times greater than ambient specific humidity. Thus, the plumage can supply a microclimate buffered from that of the exterior environment. Extrapolating survival data for Lemna minor desiccation at various temperature and humidity levels to the measured plumage microclimatic conditions of living birds, survival for up to 6 h can be anticipated, especially in crissum, crural and breast plumage. The results are discussed in the context of potential long distance epizoochorous dispersal by A. platyrhynchos and similar species.
Morphological Diversity in Crystal Growth of l-Ascorbic Acid Dissolved in Methanol
NASA Astrophysics Data System (ADS)
Ito, Miho; Izui, Machiko; Yamazaki, Yoshihiro; Matsushita, Mitsugu
2003-06-01
Morphological diagram with respect to crystal growth of l-ascorbic acid (C6H8O6; so-called vitamin C) from methanol solution on a flat glass dish is presented. Varying humidity and initial concentration of l-ascorbic acid in methanol solution, the following three distinct kinds of growing patterns have been observed: homogeneous disk, concentric ring and dendrite. In addition, in higher concentration clearly faceted small single crystals grow in any humidity less than 90%. Crossovers from one pattern to another were observed, too.
Physiological responses during continuous work in hot dry and hot humid environments in Indians
NASA Astrophysics Data System (ADS)
Sen Gupta, J.; Swamy, Y. V.; Pichan, G.; Dimri, G. P.
1984-06-01
Studies have been conducted on six young healthy heat acclimatised Indians to determine the physiological changes in prolonged continuous work in thermally neutral and in hot dry and hot humid environments. Physiological responses in maximal efforts i.e. Vo2 max, VE max and Cf max were noted. In addition, duration in continuous work at three sub-maximal rate of work in three simulated environments were also noted. Physiological responses like Vo2, VE and Cf were noted every 15 minutes of work. Besides these responses, rectal temperature (Tre), mean skin temperature (Ts) and mean sweat rate were also recorded during continuous work. Results indicated a significant decrease in maximum oxygen uptake capacity (Vo2 max) in heat with no change in maximum exercise ventilation (VE max) and maximum cardiac frequency. However, the fall in Vo2 max was more severe in the hot humid environment than in the hot dry climate. Cardiac frequency at fixed oxygen consumption of 1.0, 1.5 and 2.0 l/min was distinctly higher in the hot humid environment than in the hot dry and comfortable temperature. The duration in continuous physical effort in various grades of activities decreased in hot dry environment from that in the-comfortable climate and further decreased significantly in hot humid environment. The highest rate of sweating was observed during work in humid heat. The mean skin temperature (Ts) showed a fall in all the three rates of work in comfortable and hot dry conditions whereas in hot humid environment it showed a linear rise during the progress of work. The rectal temperature on the other hand maintained a near steady state while working at 65 and 82 watts in comfortable and hot dry environments but kept on rising during work in hot humid environment. At the highest work rate of 98 watts, the rectal temperature showed a steady increase even in the hot dry condition. It was thus concluded from the study that a hot humid climate imposes more constraints on the thermoregulatory system during work than in the hot dry condition because of less effective heat dissipation so resulting in reduced tolerance to work.
Huang, Jihong; Ma, Keping; Huang, Jianhua
2017-01-01
Based on a great number of literatures, we established the database about the Chinese endemic seed plants and analyzed the compositions, growth form, distribution and angiosperm original families of them within three big natural areas and seven natural regions. The results indicate that the above characters of Chinese endemic plants take on relative rule at the different geographical scales. Among the three big natural areas, Eastern Monsoon area has the highest endemic plants richness, whereas Northwest Dryness area is the lowest. For life forms, herbs dominate. In contrast, the proportion of herbs of Eastern Monsoon area is remarkable under other two areas. Correspondingly the proportions of trees and shrubs are substantially higher than other two. For angiosperm original families, the number is the highest in Eastern Monsoon area, and lowest in Northwest Dryness area. On the other hand, among the seven natural regions, the humid and subtropical zone in Central and Southern China has the highest endemic plants richness, whereas the humid, hemi-humid region and temperate zone in Northeast China has the lowest. For life forms, the proportion of herbs tends to decrease from humid, hemi-humid region and temperate zone in Northeast China to humid and tropical zone in Southern China. Comparably, trees, shrubs and vines or lianas increase with the same directions. This fully represents these characters of Chinese endemic plants vary with latitudinal gradients. Furthermore, as to the number of endemic plants belonging to angiosperm original families, the number is the most in humid and subtropical zone in Center and Southern China, and tropical zone in Southern China in the next place. In contrast, the endemic plant of these two regions relatively is richer than that of The Qinghai-Tibet alpine and cold region. All above results sufficiently reflect that the Chinese endemic plants mainly distribute in Eastern Monsoon area, especially humid and subtropical zone in Center and Southern China and tropical zone in Southern China. Furthermore, the flora of Eastern Monsoon area, in particular humid and subtropical zone in Center and Southern China and tropical zone in Southern China, is more ancient and original than that of Northwest Dryness area and Qinghai-Tibet alpine and cold area.
No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions
Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef
2016-01-01
Purpose Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. Methods A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. Results HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. Conclusions In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect. PMID:27126724
No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions.
Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef; Hartl, Arnulf
2016-07-01
Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect.
Towards retrieving critical relative humidity from ground-based remote sensing observations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Weverberg, Kwinten; Boutle, Ian; Morcrette, Cyril J.
2016-08-22
Nearly all parameterisations of large-scale cloud require the specification of the critical relative humidity (RHcrit). This is the gridbox-mean relative humidity at which the subgrid fluctuations in temperature and water vapour become so large that part of a subsaturated gridbox becomes saturated and cloud starts to form. Until recently, the lack of high-resolution observations of temperature and moisture variability has hindered a reasonable estimate of the RHcrit from observations. However, with the advent of ground-based measurements from Raman lidar, it becomes possible to obtain long records of temperature and moisture (co-)variances with sub-minute sample rates. Lidar observations are inherently noisymore » and any analysis of higher-order moments will be very dependent on the ability to quantify and remove this noise. We present an exporatory study aimed at understanding whether current noise levels of lidar-retrieved temperature and water vapour are sufficient to obtain a reasonable estimate of the RHcrit. We show that vertical profiles of RHcrit can be derived for a gridbox length of up to about 30 km (120) with an uncertainty of about 4 % (2 %). RHcrit tends to be smallest near the scale height and seems to be fairly insensitive to the horizontal grid spacing at the scales investigated here (30 - 120 km). However, larger sensitivity was found to the vertical grid spacing. As the grid spacing decreases from 400 to 100 m, RHcrit is observed to increase by about 6 %, which is more than the uncertainty in the RHcrit retrievals.« less
Badel-Mogollón, Jaime; Rodríguez-Figueroa, Laura; Parra-Henao, Gabriel
2017-03-29
Due to the lack of information regarding biophysical and spatio-temporal conditions (hydrometheorologic and vegetal coverage density) in areas with Triatoma dimidiata in the Colombian departments of Santander and Boyacá, there is a need to elucidate the association patterns of these variables to determine the distribution and control of this species. To make a spatio-temporal analysis of biophysical variables related to the distribution of T. dimidiate observed in the northeast region of Colombia. We used the Intergovernmental Panel on Climate Change Special Report on Emissions Scenarios (IPCC SRES) data bases registering vector presence and hydrometheorologic data. We studied the variables of environmental temperature, relative humidity, rainfall and vegetal coverage density at regional and local levels, and we conducted spatial geostatistic, descriptive statistical and Fourier temporal series analyses. Temperatures two meters above the ground and on covered surface ranged from 14,5°C to 18,8°C in the areas with the higher density of T. dimidiata. The environmental temperature fluctuated between 30 and 32°C. Vegetal coverage density and rainfall showed patterns of annual and biannual peaks. Relative humidity values fluctuated from 66,8 to 85,1%. Surface temperature and soil coverage were the variables that better explained the life cycle of T. dimidiata in the area. High relative humidity promoted the seek of shelters and an increase of the geographic distribution in the annual and biannual peaks of regional rainfall. The ecologic and anthropic conditions suggest that T. dimidiata is a highly resilient species.
Ecological covariates based predictive model of malaria risk in the state of Chhattisgarh, India.
Kumar, Rajesh; Dash, Chinmaya; Rani, Khushbu
2017-09-01
Malaria being an endemic disease in the state of Chhattisgarh and ecologically dependent mosquito-borne disease, the study is intended to identify the ecological covariates of malaria risk in districts of the state and to build a suitable predictive model based on those predictors which could assist developing a weather based early warning system. This secondary data based analysis used one month lagged district level malaria positive cases as response variable and ecological covariates as independent variables which were tested with fixed effect panelled negative binomial regression models. Interactions among the covariates were explored using two way factorial interaction in the model. Although malaria risk in the state possesses perennial characteristics, higher parasitic incidence was observed during the rainy and winter seasons. The univariate analysis indicated that the malaria incidence risk was statistically significant associated with rainfall, maximum humidity, minimum temperature, wind speed, and forest cover ( p < 0.05). The efficient predictive model include the forest cover [IRR-1.033 (1.024-1.042)], maximum humidity [IRR-1.016 (1.013-1.018)], and two-way factorial interactions between district specific averaged monthly minimum temperature and monthly minimum temperature, monthly minimum temperature was statistically significant [IRR-1.44 (1.231-1.695)] whereas the interaction term has a protective effect [IRR-0.982 (0.974-0.990)] against malaria infections. Forest cover, maximum humidity, minimum temperature and wind speed emerged as potential covariates to be used in predictive models for modelling the malaria risk in the state which could be efficiently used for early warning systems in the state.
Tamm, Maria; Jakobson, Ainika; Havik, Merle; Burk, Andres; Timpmann, Saima; Allik, Jüri; Oöpik, Vahur; Kreegipuu, Kairi
2014-01-01
The human perception of time was observed under extremely hot conditions. Young healthy men performed a time production task repeatedly in 4 experimental trials in either a temperate (22 °C, relative humidity 35%) or a hot (42 °C, relative humidity 18%) environment and with or without a moderate-intensity treadmill exercise. Within 1 hour, the produced durations indicated a significant compression of short intervals (0.5 to 10 s) in the combination of exercising and high ambient temperature, while neither variable/condition alone was enough to yield the effect. Temporal judgement was analysed in relation to different indicators of arousal, such as critical flicker frequency (CFF), core temperature, heart rate, and subjective ratings of fatigue and exertion. The arousal-sensitive internal clock model (originally proposed by Treisman) is used to explain the temporal compression while exercising in heat. As a result, we suggest that the psychological response to heat stress, the more precisely perceived fatigue, is important in describing the relationship between core temperature and time perception. Temporal compression is related to higher core temperature, but only if a certain level of perceived fatigue is accounted for, implying the existence of a thermoemotional internal clock.
Sposito, Juliana Caroline Vivian; Crispim, Bruno do Amaral; Romãn, Amanda Izadora; Mussury, Rosilda Mara; Pereira, Joelson Gonçalves; Seno, Leonardo Oliveira; Grisolia, Alexeia Barufatti
2017-05-01
In the present study, genotoxicity and mutagenicity were investigated in Tradescantia pallida exposed to vehicular traffic at different sites in a high-altitude tropical climate. During March, May, July, September, and November 2014, a comet assay and micronucleus bioassays were conducted on young inflorescences and leaves of T. pallida collected from twelve towns in the southern region of Mato Grosso do Sul with different amounts of vehicular traffic. Weather parameters (temperature, relative humidity and rainfall) were measured and vehicles were counted to determine traffic levels in each town. A higher frequency of genotoxic and mutagenic damage was observed in the municipality of Dourados. The highest frequency of genetic damage was observed in September and November according to both assays. Relative humidity and rainfall were inversely proportional to the frequency of genetic damage in T. pallida during the collection period. Based on these results, we conclude that the bioassays are efficient for assessing the effects of vehicular traffic in these towns with respect to weather conditions over time. These bioassays can be applied to identify risk areas, which are determined by climatic conditions and air pollutants released. Copyright © 2017 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The interactive effects of ambient temperature and light sources at high relative humidity on growth performance and blood physiological reactions in broilers grown to 42 day of age were investigated. The experiment consisted of 2 levels (Moderate=21.1, High=26.7 °C) of temperatures and 2 light sour...
Imaging of electrical response of NiO x under controlled environment with sub-25-nm resolution
Jacobs, Christopher B.; Ievlev, Anton V.; Collins, Liam F.; ...
2016-07-19
The spatially resolved electrical response of rf-sputtered polycrystalline NiO x films composed of 40 nm crystallites was investigated under different relative humidity levels (RH). The topological and electrical properties (surface potential and resistance) were characterized using Kelvin probe force microscopy (KPFM) and conductive scanning probe microscopy at 0%, 50%, and 80% relative humidity with sub 25nm resolution. The surface potential of NiO x decreased by about 180 mV and resistance decreased in a nonlinear fashion by about 2 G when relative humidity was increased from 0% to 80%. The dimensionality of surface features obtained through autocorrelation analysis of topological, surfacemore » potential and resistance maps increased linearly with increased relative humidity as water was adsorbed onto the film surface. Spatially resolved surface potential and resistance of the NiO x films were found to be heterogeneous, with distinct features that grew in size from about 60 nm to 175 nm between 0% and 80% RH levels, respectively. Here, we find that the changes in the heterogeneous character of the NiO films are consistent through the topological, surface potential, and resistance measurements, suggesting that the nanoscale surface potential and resistance properties converge with the mesoscale properties as water is adsorbed onto the NiO x film.« less
NASA Astrophysics Data System (ADS)
Junginger, A.; Vonhof, H.; Foerster, V. E.; Asrat, A.; Cohen, A. S.; Lamb, H. F.; Schaebitz, F.; Trauth, M. H.
2016-12-01
A major challenge in paleo-anthropology is to understand the impact of climatic changes on human evolution. The Hominin Sites and Paleo-lakes Drilling Project (HSPDP) is currently meeting that challenge by providing records that cover the last 3.7 Ma of paleoenvironmental change all located in close proximity to key paleo-anthropological findings in East Africa. One of the cored climatic archives comes from the dried up Chew Bahir basin in southern Ethiopia, where duplicate sediment cores, each 280 m long, are expected to provide valuable insights about East African environmental variability during the last >500 ka. The lake basins in the eastern branch of the East African Rift System today contain mainly shallow and alkaline lakes. However, paleo-shorelines in the form of wave cut notches, shell beds, and beach ridges are common morphological evidences for deep freshwater lakes that have filled the basins up to their overflow level during pronounced humid episodes, such as the African Humid Period (AHP, 15-5 ka). Unfortunately, further back in time, many of those morphological features disappear due to erosion and the estimation of paleo-water depths depend merely on qualitative proxies from core analyses. We here present a new method that shows high potential to translate qualitative proxy signals from sediment core analyses to quantitative climate signals in the Ethiopian Rift. The method aims at water level reconstruction of multiple paleo-lake episodes in the Chew Bahir basin using strontium isotope ratios (87Sr/86Sr, SIR) in lacustrine fossils and microfossils. SIR preserved in lacustrine fossils reflect the lithology of the drained catchment. The catchment of Chew Bahir consists mainly of Precambrian basement rocks producing high SIR in the lake waters. During humid periods, its catchment enlarged when higher elevated paleo-lakes Abaya, Chamo and Awassa were cascading down into Chew Bahir. These basins drain mainly volcanic rocks producing low SIR. First results show such an onset of hydrological connectivity in a pronounced reduction of SIR in the lacustrine fossils of Chew Bahir when the last AHP set in. This new method may help to quantify paleo-lake levels beyond the past 20 ka and may also detect migrational barriers or routes due to the occurrence of synchronous large, connected and deep paleo-lakes.
NASA Astrophysics Data System (ADS)
Hussain, F.; Khairuddin, S.; Othman, H.
2017-01-01
An inter-laboratory comparison in relative humidity measurements among accredited laboratories has been coordinated by the National Metrology Institute of Malaysia. It was carried out to determine the performance of the participating laboratories. The objective of the comparison was to acknowledge the participating laboratories competencies and to verify the level of accuracies declared in their scope of accreditation, in accordance with the MS ISO/IEC 17025 accreditation. The measurement parameter involved was relative humidity for the range of 30-90 %rh at a nominal temperature of 50°C. Eight accredited laboratories participated in the inter-laboratory comparison. Two units of artifacts have been circulated among the participants as the transfer standards.
Tanaka, Shoichiro; Iwata, Sachiko; Kinoshita, Masahiro; Tsuda, Kennosuke; Sakai, Sayaka; Saikusa, Mamoru; Shindo, Ryota; Harada, Eimei; Okada, Junichiro; Hisano, Tadashi; Kanda, Hiroshi; Maeno, Yasuki; Araki, Yuko; Ushijima, Kazuo; Sakamoto, Teruo; Yamashita, Yushiro; Iwata, Osuke
2016-12-01
Adult patients frequently suffer from serious respiratory complications during therapeutic hypothermia. During therapeutic hypothermia, respiratory gases are humidified close to saturated vapor at 37°C (44 mg/L) despite that saturated vapor reduces considerably depending on temperature reduction. Condensation may cause serious adverse events, such as bronchial edema, mucosal dysfunction, and ventilator-associated pneumonia during cooling. To determine clinical variables associated with inadequate humidification of respiratory gases during cooling, humidity of inspiratory gases was measured in 42 cumulative newborn infants who underwent therapeutic hypothermia. Three humidifier settings of 37-default (chamber outlet, 37°C; distal circuit, 40°C), 33.5-theoretical (chamber outlet, 33.5°C; distal circuit, 36.5°C), and 33.5-adjusted (optimized setting to achieve 36.6 mg/L using feedback from a hygrometer) were tested to identify independent variables of excessively high humidity >40.7 mg/L and low humidity <32.9 mg/L. The mean (SD) humidity at the Y-piece was 39.2 (5.2), 33.3 (4.1), and 36.7 (1.2) mg/L for 37-default, 33.5-theoretical, and 33.5-adjusted, respectively. The incidence of excessive high humidity was 10.3% (37-default, 31.0%; 33.5-theoretical, 0.0%; 33.5-adjusted, 0.0%), which was positively associated with the use of a counter-flow humidifier (p < 0.001), 37-default (compared with 33.5-theoretical and 33.5-adjusted, both p < 0.001) and higher fraction of inspired oxygen (p = 0.003). The incidence of excessively low humidity was 17.5% (37-default, 7.1%; 33.5-theoretical, 45.2%; 33.5-adjusted, 0.0%), which was positively associated with the use of a pass-over humidifier and 33.5-theoretical (both p < 0.001). All patients who used a counter-flow humidifier achieved the target gas humidity at the Y-piece (36.6 ± 0.5 mg/L) required for 33.5-adjusted with 33.5-theoretical. During cooling, 37-default is associated with excessively high humidity, whereas 33.5-theoretical leads to excessively low humidity. Future studies are needed to assess whether a new regimen with optimized Y-piece temperature and humidity control reduces serious respiratory adverse events during cooling.
NASA Astrophysics Data System (ADS)
Gannon, C.
2016-12-01
Climate change will have many impacts on human health, perhaps most directly through extreme heat. High temperature and humidity combinations inhibit the body's ability to cool through physiological responses such as sweating. In conjunction with extended periods of extreme heat and shifted seasonality, these conditions are particularly dangerous. Current research and literature can be used to show where dangerous heat and humidity conditions are likely to be most prevalent, or where populations vulnerable to heat stress reside. To provide a better assessment of overall heat vulnerability, however, many complex factors, such as relative changes in temperature patterns or local socioeconomic conditions, must also be considered. Here, we utilize a multivariate approach to establish county-level risk scores by combining the most relevant indicators for heat vulnerability with climate model projections of wet bulb globe temperature, a metric useful for understanding how the human body will respond to conditions of high heat and humidity. We present our findings as an ESRI ArcOnline Story Map with data aggregated at the county-level in the continental United States. This format allows users to access maps showing each county's score in four categories related to heat vulnerability: heat and humidity hazards, population vulnerability, medical access, and physical infrastructure. A final map showcases a composite heat vulnerability score for each county, with comparisons to state and national averages. Our tool, part of the White House's Climate Data Initiative, is presented as a series of maps with a normalized scoring system to provide clear and easy access to the indicators most relevant to evaluating heat vulnerability at a local level. Ultimately, this readily available tool with general indices helps community decision makers communicate heat vulnerability and identify which resilience factors are most critical to improving local resilience.
Su, Shih-Bin; Wang, Bour-Jr; Tai, Chien; Chang, Hsiu-Fen; Guo, How-Ran
2009-01-01
To determine whether working under relative humidity (RH) around 55 +/- 5% may lead to dry symptoms among workers in tropical regions. We recruited 3,154 Taiwanese workers who had no history of skin diseases and compared dry symptoms between clean room workers (RH around 55 +/- 5%) and other workers (RH around 65 +/- 5%). Clean room workers had higher prevalences of dry symptoms of the eye (odds ratio [OR]=1.62, 95% confidence interval [CI]: 1.40 to 1.86), nose and throat (OR=2.15, 95% CI: 1.66 to 2.79), and skin (OR=1.46, 95% CI: 1.23 to 1.73). In clean room workers, however, dry skin symptoms affected the palms (OR=1.72, 95% CI: 1.24 to 2.39), which are covered by gloves, more frequently than the face (OR=0.65, 95% CI: 0.45 to 0.94), which is exposed to the room air. We found working in clean rooms (adjusted OR [AOR]=1.38, 95% CI: 1.08 to 1.77), 24 to 30 yr of age (AOR=0.78, 95% CI: 0.62 to 0.99), family history of atopic diseases (AOR=1.75, 95% CI: 1.37 to 2.25), and skin moisturizer use (AOR=1.64, 95% CI: 1.30 to 2.06) were independent predictors of skin symptoms. In addition, working in clean rooms was an independent predictor of dry eye (AOR=1.30, 95% CI: 1.06 to 1.60) and dry nose and throat (AOR=1.70, 95% CI: 1.28 to 2.26) symptoms. Whereas the humidity in such working environments is not very low, for workers living in a high humidity environment, the relatively low humidity may still cause dry symptoms of the eye, nose, and throat.
Nocturnal cooling in a very shallow cold air pool
NASA Astrophysics Data System (ADS)
Rakovec, Jože; Skok, Gregor; Žabkar, Rahela; Žagar, Nedjeljka
2015-04-01
Cold air pools (CAPs) may develop during nights in very shallow depressions. The depth of the stagnant air within a CAP influences the process of the cooling of nocturnal air and the resulting minimum temperature. A seven-month long field experiment was performed during winter 2013/2014 in an orchard near Kr\\vsko, Slovenia, located inside a very shallow basin only a few meters deep and approximately 500 m wide. Two locations at different elevations inside the basin were selected for measurement. The results showed that the nights (in terms of cooling) can be classified into three main categories; nights with overcast skies and weak cooling, windy nights with clear sky and strong cooling but with no difference in temperatures between locations inside the basin, and calm nights with even stronger cooling and significant temperature differences between locations inside the basin. On calm nights with clear skies, the difference at two measuring sites inside the basin can be up to 5 °C but the presence of even weak winds can cause sufficient turbulent mixing to negate any difference in temperature. To better understand the cooling process on calm, clear nights, we developed a simple 1-D thermodynamic conceptual model focusing on a very shallow CAP. The model has 5-layers (including two air layers representing air inside the CAP), and an analytical solution was obtained for the equilibrium temperatures. Sensitivity analysis of the model was performed. As expected, a larger soil heat conductivity or higher temperature in the ground increases the morning minimum temperatures. An increase in temperature of the atmosphere also increases the simulated minimum temperatures, while the temperature difference between the higher and lower locations remains almost the same. An increase in atmosphere humidity also increases the modelled equilibrium temperatures, while an increase of the humidity of the air inside the CAP results in lower equilibrium temperatures. The humidity of the air within the CAP and that of the free atmosphere strongly influence the differences in equilibrium temperatures at higher and lower locations. The more humid the air, the stronger the cooling at the lower location compared to the higher location.
Key variables analysis of a novel continuous biodrying process for drying mixed sludge.
Navaee-Ardeh, Shahram; Bertrand, François; Stuart, Paul R
2010-05-01
A novel continuous biodrying process has been developed whose goal is to increase the dry solids content of the sludge to economic levels rendering it suitable for a safe and economic combustion operation in a biomass boiler. The sludge drying rates are enhanced by the metabolic bioheat produced in the matrix of mixed sludge. The goal of this study was to systematically analyze the continuous biodrying reactor. By performing a variable analysis, it was found that the outlet relative humidity profile was the key variable in the biodrying reactor. The influence of different outlet relative humidity profiles was then evaluated using biodrying efficiency index. It was found that by maintaining the air outlet relative humidity profile at 85/85/96/96% in the four compartments of the reactor, the highest biodrying efficiency index can be achieved, while economic dry solids level (>45%w/w) are guaranteed. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.
Relative Humidity in Limited Streamer Tubes for Stanford Linear Accelerator Center's BaBar Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lang, M.I.; /MIT; Convery, M.
2005-12-15
The BABAR Detector at the Stanford Linear Accelerator Center studies the decay of B mesons created in e{sup +}e{sup -} collisions. The outermost layer of the detector, used to detect muons and neutral hadrons created during this process, is being upgraded from Resistive Plate Chambers (RPCs) to Limited Streamer Tubes (LSTs). The standard-size LST tube consists of eight cells, where a silver-plated wire runs down the center of each. A large potential difference is placed between the wires and ground. Gas flows through a series of modules connected with tubing, typically four. LSTs must be carefully tested before installation, asmore » it will be extremely difficult to repair any damage once installed in the detector. In the testing process, the count rate in most modules showed was stable and consistent with cosmic ray rate over an approximately 500 V operating range between 5400 to 5900 V. The count in some modules, however, was shown to unexpectedly spike near the operation point. In general, the modules through which the gas first flows did not show this problem, but those further along the gas chain were much more likely to do so. The suggestion was that this spike was due to higher humidity in the modules furthest from the fresh, dry inflowing gas, and that the water molecules in more humid modules were adversely affecting the modules' performance. This project studied the effect of humidity in the modules, using a small capacitive humidity sensor (Honeywell). The sensor provided a humidity-dependent output voltage, as well as a temperature measurement from a thermistor. A full-size hygrometer (Panametrics) was used for testing and calibrating the Honeywell sensors. First the relative humidity of the air was measured. For the full calibration, a special gas-mixing setup was used, where relative humidity of the LST gas mixture could be varied from almost dry to almost fully saturated. With the sensor calibrated, a set of sensors was used to measure humidity vs. time in the LSTs. The sensors were placed in two sets of LST modules, one gas line flowing through each set. These modules were tested for count rate v. voltage while simultaneously measuring relative humidity in each module. One set produced expected readings, while the other showed the spike in count rate. The relative humidity in the two sets of modules looked very similar, but it rose significantly for modules further along the gas chain.« less
Evaluation of Diesel Exhaust Continuous Monitors in Controlled Environmental Conditions
Yu, Chang Ho; Patton, Allison P.; Zhang, Andrew; Fanac, Zhi-Hua (Tina); Weisel, Clifford P.; Lioy, Paul J.
2015-01-01
Diesel exhaust (DE) contains a variety of toxic air pollutants, including diesel particulate matter (DPM) and gaseous contaminants (e.g., carbon monoxide (CO)). DPM is dominated by fine (PM2.5) and ultrafine particles (UFP), and can be representatively determined by its thermal-optical refractory as elemental carbon (EC) or light-absorbing characteristics as black carbon (BC). The currently accepted reference method for sampling and analysis of occupational exposure to DPM is the National Institute for Occupational Safety and Health (NIOSH) Method 5040. However, this method cannot provide in-situ short-term measurements of DPM. Thus, real-time monitors are gaining attention to better examine DE exposures in occupational settings. However, real-time monitors are subject to changing environmental conditions. Field measurements have reported interferences in optical sensors and subsequent real-time readings, under conditions of high humidity and abrupt temperature changes. To begin dealing with these issues, we completed a controlled study to evaluate five real-time monitors: Airtec real-time DPM/EC Monitor, TSI SidePak Personal Aerosol Monitor AM510 (PM2.5), TSI Condensation Particle Counter 3007, microAeth AE51 BC Aethalometer, and Langan T15n CO Measurer. Tests were conducted under different temperatures (55, 70, and 80 °F), relative humidity (10, 40, and 80%), and DPM concentrations (50 and 200 µg/m3) in a controlled exposure facility. The 2-hour averaged EC measurements from the Airtec instrument showed relatively good agreement with NIOSH Method 5040 (R2=0.84; slope=1.17±0.06; N=27) and reported ~17% higher EC concentrations than the NIOSH reference method. Temperature, relative humidity, and DPM levels did not significantly affect relative differences in 2-hour averaged EC concentrations obtained by the Airtec instrument versus the NIOSH method (p<0.05). Multiple linear regression analyses, based on 1-min averaged data, suggested combined effects of up to 5% from relative humidity and temperature on real-time measurements. The overall deviations of these real-time monitors from the NIOSH method results were ≤20%. However, simultaneous monitoring of temperature and relative humidity is recommended in field investigations to understand and correct for environmental impacts on real-time monitoring data. PMID:25894766
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. P. Jensen; Toto, T.
Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25more » and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.« less
Temporal changes in climatic variables and their impact on crop yields in southwestern China
NASA Astrophysics Data System (ADS)
Liu, Hong-Bin; Gou, Yu; Wang, Hong-Ye; Li, Hong-Mei; Wu, Wei
2014-08-01
Knowledge of variability in climatic variables changes and its impact on crop yields is important for farmers and policy makers, especially in southwestern China where rainfed agriculture is dominant. In the current study, six climatic parameters (mean temperature, rainfall, relative humidity, sunshine hours, temperature difference, and rainy days) and aggregated yields of three main crops (rice: Oryza sativa L., oilseed rape: Brassica napus L., and tobacco: Nicotiana tabacum L.) during 1985-2010 were collected and analyzed for Chongqing—a large agricultural municipality of China. Climatic variables changes were detected by Mann-Kendall test. Increased mean temperature and temperature difference and decreased relative humidity were found in annual and oilseed rape growth time series ( P < 0.05). Increased sunshine hours were observed during the oilseed rape growth period ( P < 0.05). Rainy days decreased slightly in annual and oilseed rape growth time series ( P < 0.10). Correlation analysis showed that yields of all three crops could benefit from changes in climatic variables in this region. Yield of rice increased with rainfall ( P < 0.10). Yield of oilseed rape increased with mean temperature and temperature difference but decreased with relative humidity ( P < 0.01). Tobacco yield increased with mean temperature ( P < 0.05). Path analysis provided additional information about the importance and contribution paths of climatic variables to crop yields. Temperature difference and sunshine hours had higher direct and indirect effects via other climatic variables on yields of rice and tobacco. Mean temperature, relative humidity, rainy days, and temperature difference had higher direct and indirect effects via others on yield of oilseed rape.
Temporal changes in climatic variables and their impact on crop yields in southwestern China.
Liu, Hong-Bin; Gou, Yu; Wang, Hong-Ye; Li, Hong-Mei; Wu, Wei
2014-08-01
Knowledge of variability in climatic variables changes and its impact on crop yields is important for farmers and policy makers, especially in southwestern China where rainfed agriculture is dominant. In the current study, six climatic parameters (mean temperature, rainfall, relative humidity, sunshine hours, temperature difference, and rainy days) and aggregated yields of three main crops (rice: Oryza sativa L., oilseed rape: Brassica napus L., and tobacco: Nicotiana tabacum L.) during 1985-2010 were collected and analyzed for Chongqing-a large agricultural municipality of China. Climatic variables changes were detected by Mann-Kendall test. Increased mean temperature and temperature difference and decreased relative humidity were found in annual and oilseed rape growth time series (P<0.05). Increased sunshine hours were observed during the oilseed rape growth period (P<0.05). Rainy days decreased slightly in annual and oilseed rape growth time series (P<0.10). Correlation analysis showed that yields of all three crops could benefit from changes in climatic variables in this region. Yield of rice increased with rainfall (P<0.10). Yield of oilseed rape increased with mean temperature and temperature difference but decreased with relative humidity (P<0.01). Tobacco yield increased with mean temperature (P<0.05). Path analysis provided additional information about the importance and contribution paths of climatic variables to crop yields. Temperature difference and sunshine hours had higher direct and indirect effects via other climatic variables on yields of rice and tobacco. Mean temperature, relative humidity, rainy days, and temperature difference had higher direct and indirect effects via others on yield of oilseed rape.
Fiberboard Humidity Data for 9975 Shipping Packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humiditymore » and temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts« less
Greenness and Carbon Stocks of Mangroves: A climate-driven Effect
NASA Astrophysics Data System (ADS)
Lule, A. V.; Colditz, R. R.; Herrera-Silveira, J.; Guevara, M.; Rodriguez-Zuniga, M. T.; Cruz, I.; Ressl, R.; Vargas, R.
2017-12-01
Mangroves cover less than 1% of the earth's surface and are one of the most productive ecosystems of the world. They are highly vulnerable to climate variability due to their sensitivity to environmental changes; therefore, there are scientific and societal needs to designed frameworks to assess mangrove's vulnerability. We study the relationship between climate drivers, canopy greenness and carbon stocks to quantify a potential climate-driven effect on mangrove carbon dynamics. We identify greenness trends and their relationships with climate drivers and carbon stocks throughout 15 years (2001-2015) across mangrove forests of Mexico. We defined several categories for mangroves: a) Arid mangroves with superficial water input (ARsw); b) Humid mangroves with interior or underground water input (HUiw); and c) Humid mangroves with superficial water input (HUsw). We found a positive significant trend of greenness for ARsw and HUsw categories (p<0.01), a significant increment in temperature for both humid mangrove's categories (p<0.001), and a significant decrease in precipitation for ARsw (p<0.001). All mangrove categories showed higher greenness values during winter; which is likely driven by temperature with a lag of -3 to -5 months (r2 > 0.69). Precipitation and temperature drive canopy greenness only across HUsw. Regarding carbon stocks, the HUiw shows the lower amount of aboveground carbon (AGC; 12.7 Mg C ha-1) and the higher belowground carbon (BGC; 219 Mg C ha-1). The HUsw shows the higher amount of AGC (169.5 Mg C ha-1) and the ARsw the lower of BGC (92.4 Mg C ha-1). Climate drivers are better related with canopy greenness and AGC for both humid mangrove categories (r2 > 0.48), while the relationship of BGC and canopy greenness is lower for all categories (r2 < 0.21). Our results have implications for better understanding mangrove's ecosystem function and environmental services, as well as their potential vulnerability to climate variability.
Size-dependent chemical ageing of oleic acid aerosol under dry and humidified conditions
NASA Astrophysics Data System (ADS)
Al-Kindi, Suad S.; Pope, Francis D.; Beddows, David C.; Bloss, William J.; Harrison, Roy M.
2016-12-01
A chemical reaction chamber system has been developed for the processing of oleic acid aerosol particles with ozone under two relative humidity conditions: dry and humidified to 65 %. The apparatus consists of an aerosol flow tube, in which the ozonolysis occurs, coupled to a scanning mobility particle sizer (SMPS) and an aerosol time-of-flight mass spectrometer (ATOFMS) which measure the evolving particle size and composition. Under both relative humidity conditions, ozonolysis results in a significant decrease in particle size and mass which is consistent with the formation of volatile products that partition from the particle to the gas phase. Mass spectra derived from the ATOFMS reveal the presence of the typically observed reaction products: azelaic acid, nonanal, oxononanoic acid and nonanoic acid, as well as a range of higher molecular weight products deriving from the reactions of reaction intermediates with oleic acid and its oxidation products. These include octanoic acid and 9- and 10-oxooctadecanoic acid, as well as products of considerably higher molecular weight. Quantitative evaluation of product yields with the ATOFMS shows a marked dependence upon both particle size association (from 0.3 to 2.1 µm diameter) and relative humidity. Under both relative humidity conditions, the percentage residual of oleic acid increases with increasing particle size and the main lower molecular weight products are nonanal and oxononanoic acid. Under dry conditions, the percentage of higher molecular weight products increases with increasing particle size due to the poorer internal mixing of the larger particles. Under humidified conditions, the percentage of unreacted oleic acid is greater, except in the smallest particle fraction, with little formation of high molecular weight products relative to the dry particles. It is postulated that water reacts with reactive intermediates, competing with the processes which produce high molecular weight products. Whilst the oleic acid model aerosol system is of limited relevance to complex internally mixed atmospheric aerosol, the generic findings presented in this paper give useful insights into the nature of heterogeneous chemical processes.
NASA Astrophysics Data System (ADS)
Ettler, Vojtech; Kribek, Bohdan; Mihaljevic, Martin; Vanek, Ales; Penizek, Vit; Sracek, Ondra; Mapani, Ben; Kamona, Fred; Nyambe, Imasiku
2017-04-01
Soils in the vicinity of non-ferrous metal smelters are often highly polluted by inorganic contaminants released from particulate emissions, which undergo weathering processes and release contaminants when deposited in soils. We studied the heavy mineral fraction, separated from mining- and smelter-affected topsoils, from both a humid subtropical area in the Zambian Copperbelt and a hot semi-arid area in the northern Namibia. High concentrations of metal(loid)s were detected in the studied soils: up to 1450 ppm As, 8980 ppm Cu, 4640 ppm Pb, 2620 ppm Zn. A combination of X-ray diffraction analysis (XRD), scanning electron microscopy (SEM/EDS), and electron probe microanalysis (EPMA) helped to identify the phases forming individual metal(loid)-bearing particles. Whereas spherical particles originate from the smelting and flue gas cleaning processes, angular particles either have geogenic origins or they are windblown from the mining operations and mine waste disposal sites. Sulphides from ores and mine tailings often exhibit weathering rims in contrast to smelter-derived high-temperature sulphides (chalcocite [Cu2S], digenite [Cu9S5], covellite [CuS], non-stoichiometric quenched Cu-Fe-S phases). Soils from humid subtropical areas exhibit higher available concentrations of metal(loids), and higher frequencies of weathering features (especially for copper-bearing oxides such as delafossite [CuFeO2]) are observed. In contrast, metal(loid)s are efficiently retained in semi-arid soils, where a high proportion of non-weathered smelter slag particles and low-solubility Ca-Cu-Pb arsenates occur. Our results indicate that compared to semi-arid areas (where inorganic contaminants were rather immobile in soils despite their high concentrations) a higher potential risk exists for agriculture in mine- and smelter-affected humid subtropical areas (where metal(loid) contaminants can be highly available for the uptake by crops). This study was supported by the Czech Science Foundation projects (GACR 13-17501S and 16-13142S).
Chowdhury, Fazle Rabbi; Ibrahim, Quazi Shihab Uddin; Bari, Md Shafiqul; Alam, M M Jahangir; Dunachie, Susanna J; Rodriguez-Morales, Alfonso J; Patwary, Md Ismail
2018-01-01
Bangladesh is one of the world's most vulnerable countries for climate change. This observational study examined the association of temperature, humidity and rainfall with six common climate-sensitive infectious diseases in adults (malaria, diarrheal disease, enteric fever, encephalitis, pneumonia and bacterial meningitis) in northeastern Bangladesh. Subjects admitted to the adult medicine ward of a tertiary referral hospital in Sylhet, Bangladesh from 2008 to 2012 with a diagnosis of one of the six chosen climate-sensitive infectious diseases were enrolled in the study. Climate-related data were collected from the Bangladesh Meteorological Institute. Disease incidence was then analyzed against mean temperature, humidity and average rainfall for the Sylhet region. Statistical significance was determined using Mann-Whitney test, Chi-square test and ANOVA testing. 5033 patients were enrolled (58% male, 42% female, ratio 1.3:1). All six diseases showed highly significant (p = 0.01) rises in incidence between the study years 2008 (540 cases) and 2012 (1330 cases), compared with no significant rise in overall all-cause hospital admissions in the same period (p = 0.19). The highest number of malaria (135), diarrhea (266) and pneumonia (371) cases occurred during the rainy season. On the other hand, the maximum number of enteric fever (408), encephalitis (183) and meningitis (151) cases occurred during autumn, which follows the rainy season. A positive (P = 0.01) correlation was observed between increased temperature and the incidence of malaria, enteric fever and diarrhea, and a negative correlation with encephalitis, meningitis and pneumonia. Higher humidity correlated (P = 0.01) with a higher number of cases of malaria and diarrhea, but inversely correlated with meningitis and encephalitis. Higher incidences of encephalitis and meningitis occurred while there was low rainfall. Incidences of diarrhea, malaria and enteric fever, increased with rainfall, and then gradually decreased. The findings support a relationship between weather patterns and disease incidence, and provide essential baseline data for future large prospective studies.
Roces, Flavio
2017-01-01
Nest ventilation in the leaf-cutting ant Atta vollenweideri is driven via a wind-induced mechanism. On their nests, workers construct small turrets that are expected to facilitate nest ventilation. We hypothesized that the construction and structural features of the turrets would depend on the colony’s current demands for ventilation and thus might be influenced by the prevailing environmental conditions inside the nest. Therefore, we tested whether climate-related parameters, namely airflow, air humidity and CO2 levels in the outflowing nest air influenced turret construction in Atta vollenweideri. In the laboratory, we simulated a semi-natural nest arrangement with fungus chambers, a central ventilation tunnel providing outflow of air and an aboveground building arena for turret construction. In independent series, different climatic conditions inside the ventilation tunnel were experimentally generated, and after 24 hours, several features of the built turret were quantified, i.e., mass, height, number and surface area (aperture) of turret openings. Turret mass and height were similar in all experiments even when no airflow was provided in the ventilation tunnel. However, elevated CO2 levels led to the construction of a turret with several minor openings and a larger total aperture. This effect was statistically significant at higher CO2 levels of 5% and 10% but not at 1% CO2. The construction of a turret with several minor openings did not depend on the strong differences in CO2 levels between the outflowing and the outside air, since workers also built permeated turrets even when the CO2 levels inside and outside were both similarly high. We propose that the construction of turrets with several openings and larger opening surface area might facilitate the removal of CO2 from the underground nest structure and could therefore be involved in the control of nest climate in leaf-cutting ants. PMID:29145459
Evolution of Lake Turkana level at the end of the African Humid Period: modalities and forcings
NASA Astrophysics Data System (ADS)
Nutz, A.; Schuster, M.
2015-12-01
The African Humid Period (AHP), ca. 11,000 to 5,000 years ago, is a major phase that had significant impacts on the environments, ecosystems, and human occupation of Africa over several millennia. One of the most marked aspects stemming from an increase in rainfall during this climate period was the creation of numerous regional lakes and the recording of highstands for these waterbodies. The termination of the AHP is known to have been time-transgressive depending on the location, being either abrupt or gradual, thereby highlighting the complex interaction among multiple forcings and responses. Lake Turkana is one of the great lakes of the East African Rift where chronology of the AHP termination has already been investigated. In this study, the delta complex of the Turkwel River is analyzed using trajectory analysis in order to provide modalities of lake level decline during that time. Trajectories reveal six slightly descending (slope gradient: >0° to 0.4°) plateaus separated by four abrupt steps having higher slope gradients (1° to 3.8°). These abrupt steps reveal repeated short-lived strong increases in the rate of lake level decline that are superimposed on the relatively steady lake level decrease characterizing this period. This marks a stepwise forced regression at the end of the AHP in the Lake Turkana. We correlate the short-lived increases in the rate of lake level decline with short-lived abrupt decreases of solar irradiance. Through the termination of the AHP, the abrupt decreases in solar irradiance modulated the continuous precessional-based reduction of solar insulation that drastically impacted monsoon activity (i.e. rainfall) and led to variations in lake levels as a response. This suggests that short-term solar variability is able to modulate longer-term orbitally-driven climate trends having significant impacts in terms of hydrology and the regional continental environments.
Halboth, Florian; Roces, Flavio
2017-01-01
Nest ventilation in the leaf-cutting ant Atta vollenweideri is driven via a wind-induced mechanism. On their nests, workers construct small turrets that are expected to facilitate nest ventilation. We hypothesized that the construction and structural features of the turrets would depend on the colony's current demands for ventilation and thus might be influenced by the prevailing environmental conditions inside the nest. Therefore, we tested whether climate-related parameters, namely airflow, air humidity and CO2 levels in the outflowing nest air influenced turret construction in Atta vollenweideri. In the laboratory, we simulated a semi-natural nest arrangement with fungus chambers, a central ventilation tunnel providing outflow of air and an aboveground building arena for turret construction. In independent series, different climatic conditions inside the ventilation tunnel were experimentally generated, and after 24 hours, several features of the built turret were quantified, i.e., mass, height, number and surface area (aperture) of turret openings. Turret mass and height were similar in all experiments even when no airflow was provided in the ventilation tunnel. However, elevated CO2 levels led to the construction of a turret with several minor openings and a larger total aperture. This effect was statistically significant at higher CO2 levels of 5% and 10% but not at 1% CO2. The construction of a turret with several minor openings did not depend on the strong differences in CO2 levels between the outflowing and the outside air, since workers also built permeated turrets even when the CO2 levels inside and outside were both similarly high. We propose that the construction of turrets with several openings and larger opening surface area might facilitate the removal of CO2 from the underground nest structure and could therefore be involved in the control of nest climate in leaf-cutting ants.
Spatio-temporal variability of particulate matter in the key part of Gansu Province, Western China.
Guan, Qingyu; Cai, Ao; Wang, Feifei; Yang, Liqin; Xu, Chuanqi; Liu, Zeyu
2017-11-01
To investigate the spatial and temporal behaviors of particulate matter in Lanzhou, Jinchang and Jiayuguan during 2014, the hourly concentrations of PM2.5 and PM10 were collected from the Ministry of Environmental Protection (MEP) in this study. The analysis indicated that the mean annual PM10 (PM2.5) concentrations during 2014 were 115 ± 52 μg/m 3 (57 ± 28 μg/m 3 ), 104 ± 75 μg/m 3 (38 ± 22 μg/m 3 ) and 114 ± 72 μg/m 3 (32 ± 17 μg/m 3 ) in Lanzhou, Jinchang and Jiayuguan, respectively, all of which exceeded the Chinese national ambient air quality II standards for PM. Higher values for both PM fractions were generally observed in spring and winter, and lower concentrations were found in summer and autumn. Besides, the trend of seasonal variation of particulate matter (PM) in each city monitoring site is consistent with the average of the corresponding cities. Anthropogenic activities along with the boundary layer height and wind scale contributed to diurnal variations in PM that varied bimodally (Lanzhou and Jinchang) or unimodally (Jiayuguan). With the arrival of dust events, the PM10 concentrations changed dramatically, and the PM10 concentrations during dust storm events were, respectively, 19, 43 and 17 times higher than the levels before dust events in Lanzhou, Jinchang and Jiayuguan. The ratios (PM2.5/PM10) were lowest, while the correlations were highest, indicating that dust events contributed more coarse than fine particles, and the sources of PM are similar during dust storms. The relationships between local meteorological parameters and PM concentrations suggest a clear association between the highest PM concentrations, with T ≤ 7 °C, and strong winds (3-4 scale). However, the effect of relative humidity is complicated, with more PM10 and PM2.5 exceedances being registered with a relative humidity of less than 40% and 40-60% in Lanzhou, while higher exceedances in Jinchang appeared at a relative humidity of 80-100%. Copyright © 2017 Elsevier Ltd. All rights reserved.
[Ecological basis of epiphytic Dendrobium officinale growth on cliff].
Liu, Xiu-Juan; Zhu, Yan; Si, Jin-Ping; Wu, Ling-Shang; Cheng, Xue-Liang
2016-08-01
In order to make Dendrobium officinale return to the nature, the temperature and humidity in whole days of the built rock model with different slopes and aspects in the natural distribution of wild D. officinale in Tianmu Mountain were recorded by MH-WS01 automatic recorder. The results showed that the slope has a significant impact on the extreme temperature on the surface of the rocks. In summer, the extreme temperature on the surface of horizontal or soft rock can reach to 69.4 ℃, while the temperatures were lower than 50 ℃ on the vertical rock. In winter, the temperatures on the surface of vertical rock were higher and the low temperature duration was shorter than those on the horizontal or soft rock. Also, the humidity of the rocks was significantly influenced by the slope. The monthly average humidity on the surface of vertical rock was above 80%RH. Furthermore, the aspect had a significant impact on the temperature and humidity on the surface of the rocks, but had no significant effect on the daily mean temperature and extreme temperature on the surface of vertical rock. Therefore, the slope affects the survival of D. officinale by affecting the extreme temperature of rocks and affects the growth of D. officinale by affecting the humidity. The choice of slope is the key to the success of cliff epiphytic cultivation for D. officinale. Copyright© by the Chinese Pharmaceutical Association.
Mahdavi, Alireza; Haghighat, Fariborz; Bahloul, Ali; Brochot, Clothilde; Ostiguy, Claude
2015-06-01
It is necessary to investigate the efficiencies of filtering facepiece respirators (FFRs) exposed to ultrafine particles (UFPs) for long periods of time, since the particle loading time may potentially affect the efficiency of FFRs. This article aims to investigate the filtration efficiency for a model of electrostatic N95 FFRs with constant and 'inhalation-only' cyclic flows, in terms of particle loading time effect, using different humidity conditions. Filters were exposed to generated polydisperse NaCl particles. Experiments were performed mimicking an 'inhalation-only' scenario with a cyclic flow of 85 l min(-1) as the minute volume [or 170 l min(-1) as mean inhalation flow (MIF)] and for two constant flows of 85 and 170 l min(-1), under three relative humidity (RH) levels of 10, 50, and 80%. Each test was performed for loading time periods of 6h and the particle penetration (10-205.4nm in electrical mobility diameter) was measured once every 2h. For a 10% RH, the penetration of smaller size particles (<80nm), including the most penetrating particle size (MPPS), decreased over time for both constant and cyclic flows. For 50 and 80% RH levels, the changes in penetration were typically observed in an opposite direction with less magnitude. The penetrations at MPPS increased with respect to loading time under constant flow conditions (85 and 170 l min(-1)): it did not substantially increase under cyclic flows. The comparison of the cyclic flow (85 l min(-1) as minute volume) and constant flow equal to the cyclic flow minute volume indicated that, for all conditions the penetration was significantly less for the constant flow than that of cyclic flow. The comparison between the cyclic (170 l min(-1) as MIF) and constant flow equal to cyclic flow MIF indicated that, for the initial stage of loading, the penetrations were almost equal, but they were different for the final stages of the loading time. For a 10% RH, the penetration of a wide range of sizes was observed to be higher with the cyclic flow (170 as MIF) than with the equivalent constant flow (170 l min(-1)). For 50 and 80% RH levels, the penetrations were usually greater with a constant flow (170 l min(-1)) than with a cyclic flow (170 l min(-1) as MIF). It is concluded that, for the tested electrostatic N95 filters, the change in penetration as a function of the loading time does not necessarily take place with the same rate under constant (MIF) and cyclic flow. Moreover, for all tested flow rates, the penetration is not only affected by the loading time but also by the RH level. Lower RH levels (10%) have decreasing penetration rates in terms of loading time, while higher RH levels (50 and 80%) have increasing penetration rates. Also, the loading of the filter is normally accompanied with a shift of MPPS towards larger sizes. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Schoelch, Simon; Vapaavuori, Jaana; Rollet, Frédéric-Guillaume; Barrett, Christopher J
2017-01-01
Humidity detection, and the quest for low-cost facile humidity-sensitive indicator materials is of great interest for many fields, including semi-conductor processing, food transport and storage, and pharmaceuticals. Ideal humidity-detection materials for a these applications might be based on simple clear optical readout with no power supply, i.e.: a clear color change observed by the naked eye of any untrained observer, since it doesn't require any extra instrumentation or interpretation. Here, the introduction of a synthesis-free one-step procedure, based on physical mixing of easily available commercial materials, for producing a humidity memory material which can be easily painted onto a wide variety of surfaces and undergoes a remarkable color change (approximately 100 nm blue-shift of λ MAX ) upon exposure to various thresholds of levels of ambient humidity is reported. This strong color change, easily visible to as a red-to-orange color switch, is locked in until inspection, but can then be restored reversibly if desired, after moderate heating. By taking advantage of spontaneously-forming reversible 'soft' supramolecular bonds between a red-colored azo dye and a host polymer matrix, a reversible dye 'migration' aggregation appearing orange, and dis-aggregation back to red can be achieved, to function as the sensor. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Stevens, M.; Benyon, R.; Bell, S. A.; Vicente, T.
2008-10-01
In order to effectively implement the Mutual Recognition Arrangement (MRA) of the International Committee for Weights and Measures (CIPM), national metrology institutes (NMIs) are required to support their claims of calibration and measurement capability (CMC) with a quality system compliant with ISO/IEC 17025, and with suitable evidence of participation in key or supplementary comparisons. The CMC review process, both at regional and inter-regional levels, uses criteria that combine the provisions mentioned above, together with additional evidence demonstrating scientific and technical competence of the institutes. For dew-point temperatures, there are key comparisons in progress under the Consultative Committee for Thermometry (CCT) and under the European regional metrology organisation (EUROMET), together with information available on past regional supplementary comparisons. However, for relative humidity there are, to date, no such comparisons available to support CMC entries. This paper presents and discusses the results of a preliminary investigation of the use of relative humidity and temperature transmitters in order to determine their suitability for the intercomparison of standard humidity generators in support of CMC claims for the calibration of relative humidity instruments. The results of a recent bilateral comparison between 2 NMIs at the extremes of the range up to 98%rh at 70 °C, and down to 1%rh at -40 °C are reported. Specific precautions and recommendations on the use of the devices as transfer standards are presented.
Leivo, Virpi; Prasauskas, Tadas; Du, Liuliu; Turunen, Mari; Kiviste, Mihkel; Aaltonen, Anu; Martuzevicius, Dainius; Haverinen-Shaughnessy, Ulla
2018-04-15
Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO 2 ) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO 2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO 2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use. Copyright © 2017 Elsevier B.V. All rights reserved.
Inventory of File spread.sref.cluster1.f03.grib2
Records: 40 Number Level/Layer Parameter Forecast Valid Description 001 2 m above ground TMP 3 hour fcst Temperature [K] std dev 002 2 m above ground TMP 3 hour fcst Temperature [K] std dev 003 2 m above ground SPFH 3 hour fcst Specific Humidity [kg/kg] std dev 004 2 m above ground RH 3 hour fcst Relative Humidity
Stable and Selective Humidity Sensing Using Stacked Black Phosphorus Flakes.
Yasaei, Poya; Behranginia, Amirhossein; Foroozan, Tara; Asadi, Mohammad; Kim, Kibum; Khalili-Araghi, Fatemeh; Salehi-Khojin, Amin
2015-10-27
Black phosphorus (BP) atomic layers are known to undergo chemical degradation in humid air. Yet in more robust configurations such as films, composites, and embedded structures, BP can potentially be utilized in a large number of practical applications. In this study, we explored the sensing characteristics of BP films and observed an ultrasensitive and selective response toward humid air with a trace-level detection capability and a very minor drift over time. Our experiments show that the drain current of the BP sensor increases by ∼4 orders of magnitude as the relative humidity (RH) varies from 10% to 85%, which ranks it among the highest ever reported values for humidity detection. The mechanistic studies indicate that the operation principle of the BP film sensors is based on the modulation in the leakage ionic current caused by autoionization of water molecules and ionic solvation of the phosphorus oxoacids produced on moist BP surfaces. Our stability tests reveal that the response of the BP film sensors remains nearly unchanged after prolonged exposures (up to 3 months) to ambient conditions. This study opens up the route for utilizing BP stacked films in many potential applications such as energy generation/storage systems, electrocatalysis, and chemical/biosensing.
Humidity-controlled rectification switching in ruthenium-complex molecular junctions
NASA Astrophysics Data System (ADS)
Atesci, Huseyin; Kaliginedi, Veerabhadrarao; Celis Gil, Jose A.; Ozawa, Hiroaki; Thijssen, Joseph M.; Broekmann, Peter; Haga, Masa-aki; van der Molen, Sense Jan
2018-02-01
Although molecular rectifiers were proposed over four decades ago1,2, until recently reported rectification ratios (RR) were rather moderate2-11 (RR 101). This ceiling was convincingly broken using a eutectic GaIn top contact12 to probe molecular monolayers of coupled ferrocene groups (RR 105), as well as using scanning tunnelling microscopy-break junctions13-16 and mechanically controlled break junctions17 to probe single molecules (RR 102-103). Here, we demonstrate a device based on a molecular monolayer in which the RR can be switched by more than three orders of magnitude (between RR 100 and RR ≥ 103) in response to humidity. As the relative humidity is toggled between 5% and 60%, the current-voltage (I-V) characteristics of a monolayer of di-nuclear Ru-complex molecules reversibly change from symmetric to strongly asymmetric (diode-like). Key to this behaviour is the presence of two localized molecular orbitals in series, which are nearly degenerate in dry circumstances but become misaligned under high humidity conditions, due to the displacement of counter ions (PF6-). This asymmetric gating of the two relevant localized molecular orbital levels results in humidity-controlled diode-like behaviour.
Thermal Effectiveness of Wall Indoor Fountain in Warm Humid Climate
NASA Astrophysics Data System (ADS)
Seputra, J. A. P.
2018-03-01
Nowadays, many buildings wield indoor water features such as waterfalls, fountains, and water curtains to improve their aesthetical value. Despite the provision of air cooling due to water evaporation, this feature also has adverse effect if applied in warm humid climate since evaporation might increase air humidity beyond the comfort level. Yet, there are no specific researches intended to measure water feature’s effect upon its thermal condition. In response, this research examines the influence of evaporative cooling on indoor wall fountain toward occupant’s thermal comfort in warm humid climate. To achieve this goal, case study is established in Waroeng Steak Restaurant’s dining room in Surakarta-Indonesia. In addition, SNI 03-6572-2001 with comfort range of 20.5–27.1°C and 40-60% of relative humidity is utilized as thermal criterion. Furthermore, Computational Fluid Dynamics (CFD) is employed to process the data and derive conclusions. Research variables are; feature’s height, obstructions, and fan types. As results, Two Bumps Model (ToB) is appropriate when employs natural ventilation. However, if the room is mechanically ventilated, Three Bumps Model (TeB) becomes the best choice. Moreover, application of adaptive ventilation is required to maintain thermal balance.
A Fine-Tuned Metal-Organic Framework for Autonomous Indoor Moisture Control.
AbdulHalim, Rasha G; Bhatt, Prashant M; Belmabkhout, Youssef; Shkurenko, Aleksander; Adil, Karim; Barbour, Leonard J; Eddaoudi, Mohamed
2017-08-09
Conventional adsorbents, namely zeolites and silica gel, are often used to control humidity by adsorbing water; however, adsorbents capable of the dual functionality of humidification and dehumidification, offering the desired control of the moisture level at room temperature, have yet to be explored. Here we report Y-shp-MOF-5, a hybrid microporous highly connected rare-earth-based metal-organic framework (MOF), with dual functionality for moisture control within the recommended range of relative humidity (45%-65% RH) set by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). Y-shp-MOF-5 exhibits exceptional structural integrity, robustness, and unique humidity-control performance, as confirmed by the large number (thousand) of conducted water vapor adsorption-desorption cycles. The retained structural integrity and the mechanism of water sorption were corroborated using in situ single-crystal X-ray diffraction (SCXRD) studies. The resultant working water uptake of 0.45 g·g -1 is solely regulated by a simple adjustment of the relative humidity, positioning this hydrolytically stable MOF as a prospective adsorbent for humidity control in confined spaces, such as space shuttles, aircraft cabins, and air-conditioned buildings.
Fungal spores overwhelm biogenic organic aerosols in a midlatitudinal forest
NASA Astrophysics Data System (ADS)
Zhu, Chunmao; Kawamura, Kimitaka; Fukuda, Yasuro; Mochida, Michihiro; Iwamoto, Yoko
2016-06-01
Both primary biological aerosol particles (PBAPs) and oxidation products of biogenic volatile organic compounds (BVOCs) contribute significantly to organic aerosols (OAs) in forested regions. However, little is known about their relative importance in diurnal timescales. Here, we report biomarkers of PBAP and secondary organic aerosols (SOAs) for their diurnal variability in a temperate coniferous forest in Wakayama, Japan. Tracers of fungal spores, trehalose, arabitol and mannitol, showed significantly higher levels in nighttime than daytime (p < 0.05), resulting from the nocturnal sporulation under near-saturated relative humidity. On the contrary, BVOC oxidation products showed higher levels in daytime than nighttime, indicating substantial photochemical SOA formation. Using tracer-based methods, we estimated that fungal spores account for 45 % of organic carbon (OC) in nighttime and 22 % in daytime, whereas BVOC oxidation products account for 15 and 19 %, respectively. To our knowledge, we present for the first time highly time-resolved results that fungal spores overwhelmed BVOC oxidation products in contributing to OA especially in nighttime. This study emphasizes the importance of both PBAPs and SOAs in forming forest organic aerosols.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ismail, A. S., E-mail: kyrin-samaxi@yahoo.com; Mamat, M. H., E-mail: mhmamat@salam.uitm.edu.my; Rusop, M., E-mail: rusop@salam.uitm.my
2016-07-06
Effects of different morphological structures of ZnO to the performance of the device in the humidity sensing have been studied. Two different kinds of nanostructures were obtained which are nanords and nanoflakes. From the surface morphology image, the ZnO nanoflakes has lower diameter size of 100 nm compared to ZnO nanorods of 250 nm. The ZnO nanoflakes are not aligned and has low porous structure compared to ZnO nanorods. The humidity sensor performance of ZnO nanorods has superior performance compared to ZnO nanoflakes. The sensitivity of the ZnO nanorods sensor is 3.20 which are almost two times higher than themore » ZnO nanoflakes of 1.65. The structural properties of the samples have been characterized using field emission scanning electron microscopy (FESEM) electrical properties has been characterized using current voltage (I-V) measurement.« less
Fassassi, Mikaïla; Michel, Fabrice; Thomachot, Laurent; Nicaise, Claire; Vialet, Renaud; Jammes, Yves; Lagier, Pierre; Martin, Claude
2007-02-01
We set out to evaluate the efficacy of passive inspiratory gas conditioning in mechanically ventilated neonates and compared it with that of a heated humidifier (HH). Prospective, randomized, controlled study. Neonatal and pediatric intensive care unit. Fourteen mechanically ventilated neonates nursed in incubators. The HH was set to deliver a temperature of 37 degrees C and an absolute humidity of 40 mgH(2)O/l at the incubator entrance. Inspired temperature (T degrees ) and absolute humidity (AH) were measured by the psychometric method, transpulmonary pressure (Tpres) by means of a differential pressure transducer. Measurements were performed at 5, 10, and 15 min. The values of T degrees were significantly higher using the HH (34.6+/-1.6 degrees C) than the heat and moisture exchanger (HME) (33.8+/2.3, p<0.001). The values of AH were significantly higher using the HH (36.6+/-2.5 mgH(2)O/l) than the HME (32.4+/-2.8 mgH(2)O/l, p<0.001). No significant changes were observed in transpulmonary pressure. A significant positive correlation was observed between incubator temperature and the temperature delivered by the HH (R(2)=0.61, p<0.001). The use of HMEs in neonates made it possible to achieve an absolute humidity of 28 mgH(2)O/l or more and a temperature of 30 degrees C or more. Higher values are obtained using a HH.
Garcês, Alice P J T; Afonso, Sónia M Santana; Chilundo, Abel; Jairoce, Chenjerai T S
2017-02-01
The availability of wood by-products for bedding material is falling in many regions due to rising demand for other uses. The objective of this study was to evaluate six alternative litter sources-river bed sand, coconut husk, rice hulls, Guinea grass, newspaper, and corncob-as a substitute for wood shavings (WS). The trial was carried out over 35 days in an open-sided and naturally ventilated broiler house under conditions of high ambient temperatures and relative humidity. During the brooding period (0 to 14 days), chicks raised on grass had lower (P < 0.05) footpad temperature than those grown on WS. After the brooding period (15 to 35 days), the temperatures of both litter and birds were higher (P < 0.05) for coconut husk than for WS. Grass litter resulted in lower (P < 0.05) final BW, FCR, and production efficiency. Sand and rice hulls were associated with lower (P < 0.05) survival rate and higher (P < 0.05) gizzard weight. Litter type did not affect carcass and meat yields. The footpad dermatitis score, associating incidence and severity, was not statistically different among the litter substrates tested, although numerically higher in coconut husk, grass, and corncob. The results obtained in this experiment indicate that, in a hot and humid environment, all materials except grass can be used as a substitute for wood shavings with comparable production efficiency.
Afrane, Yaw A.; Little, Tom J.; Lawson, Bernard W.; Githeko, Andrew K.
2008-01-01
We investigated the effects of deforestation on microclimates and sporogonic development of Plasmodium falciparum parasites in Anopheles gambiae mosquitoes in an area of the western Kenyan highland prone to malaria epidemics. An. gambiae mosquitoes were fed with P. falciparum–infected blood through membrane feeders. Fed mosquitoes were placed in houses in forested and deforested areas in a highland area (1,500 m above sea level) and monitored for parasite development. Deforested sites had higher temperatures and relative humidities, and the overall infection rate of mosquitoes was increased compared with that in forested sites. Sporozoites appeared on average 1.1 days earlier in deforested areas. Vectorial capacity was estimated to be 77.7% higher in the deforested site than in the forested site. We showed that deforestation changes microclimates, leading to more rapid sporogonic development of P. falciparum and to a marked increase of malaria risk in the western Kenyan highland. PMID:18826815
Schüller, Laura K; Heuwieser, Wolfgang
2016-08-01
The objectives of this study were to examine heat stress conditions at cow level and to investigate the relationship to the climate conditions at 5 different stationary locations inside a dairy barn. In addition, we compared the climate conditions at cow level between primiparous and multiparous cows for a period of 1 week after regrouping. The temperature-humidity index (THI) differed significantly between all stationary loggers. The lowest THI was measured at the window logger in the experimental stall and the highest THI was measured at the central logger in the experimental stall. The THI at the mobile cow loggers was 2·33 THI points higher than at the stationary loggers. Furthermore, the mean daily THI was higher at the mobile cow loggers than at the stationary loggers on all experimental days. The THI in the experimental pen was 0·44 THI points lower when the experimental cow group was located inside the milking parlour. The THI measured at the mobile cow loggers was 1·63 THI points higher when the experimental cow group was located inside the milking parlour. However, there was no significant difference for all climate variables between primiparous and multiparous cows. These results indicate, there is a wide range of climate conditions inside a dairy barn and especially areas with a great distance to a fresh air supply have an increased risk for the occurrence of heat stress conditions. Furthermore, the heat stress conditions are even higher at cow level and cows not only influence their climatic environment, but also generate microclimates within different locations inside the barn. Therefore climate conditions should be obtained at cow level to evaluate the heat stress conditions that dairy cows are actually exposed to.