van Wagenberg, Coen P A; Backus, Gé B C; Wisselink, Henk J; van der Vorst, Jack G A J; Urlings, Bert A P
2013-09-01
In this paper we analyze the impact of the sensitivity and specificity of a Mycobacterium avium (Ma) test on pig producer incentives to control Ma in finishing pigs. A possible Ma control system which includes a serodiagnostic test and a penalty on finishing pigs in herds detected with Ma infection was modelled. Using a dynamic optimization model and a grid search of deliveries of herds from pig producers to slaughterhouse, optimal control measures for pig producers and optimal penalty values for deliveries with increased Ma risk were identified for different sensitivity and specificity values. Results showed that higher sensitivity and lower specificity induced use of more intense control measures and resulted in higher pig producer costs and lower Ma seroprevalence. The minimal penalty value needed to comply with a threshold for Ma seroprevalence in finishing pigs at slaughter was lower at higher sensitivity and lower specificity. With imperfect specificity a larger sample size decreased pig producer incentives to control Ma seroprevalence, because the higher number of false positives resulted in an increased probability of rejecting a batch of finishing pigs irrespective of whether the pig producer applied control measures. We conclude that test sensitivity and specificity must be considered in incentive system design to induce pig producers to control Ma in finishing pigs with minimum negative effects. Copyright © 2013 Elsevier B.V. All rights reserved.
Di Leo, Giovanni; Fisci, Erica; Secchi, Francesco; Alì, Marco; Ambrogi, Federico; Sconfienza, Luca Maria; Sardanelli, Francesco
2016-10-01
To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. • MRCA sensitivity and specificity for CAD are below those of CTA. • Contrast administration increased sensitivity to 95 % (90-97 %), comparable with that of CTA. • Whole-heart mode increased specificity to 78 % (72-84 %), comparable with that of CTA. • Specificity at 3 T was borderline-significantly higher (p = 0.067) than at 1.5 T. • Whole-heart contrast-enhanced protocols are the best approach for MRCA.
Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita
2010-01-01
Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832
A proposed cutoff point of waist-to-height ratio for metabolic risk in African township adolescents.
Kruger, H Salome; Faber, Mieke; Schutte, Aletta E; Ellis, Suria M
2013-03-01
A waist:height ratio (WHtR) higher than 0.5 has been proposed as a cutoff point for abdominal obesity in both sexes and at all ages. It is unknown if this cutoff point is appropriate for previously undernourished adolescents. We assessed the cutoff value of the WHtR associated with an increased metabolic risk in 178 black South African 14- to 18-y-old adolescents (69 boys, 109 girls). We measured weight, height, waist circumference, fasting plasma glucose and insulin levels, serum high-sensitivity C-reactive protein, and blood pressure and calculated the WHtR and homeostasis model assessment of insulin resistance (HOMA-IR). Using receiver operating characteristics curve analyses, we assessed the WHtR with the highest sensitivity and specificity to discriminate adolescents with increased fasting plasma glucose, HOMA-IR, serum high-sensitivity C-reactive protein, and blood pressure from those with "normal" values. The WHtR cutoff points derived from the receiver operating characteristics curves ranged from 0.40 to 0.41, with best diagnostic value at 0.41. A WHtR of 0.40 had 80% sensitivity and 38.5% specificity to classify adolescents with fasting blood glucose level higher than 5.6 mmol/L (area under the curve [AUC] 0.57). A WHtR of 0.41 had 64% sensitivity and 58.5% specificity for a HOMA-IR higher than 3.4 (AUC 0.66), 55% sensitivity and 55.6% specificity for a high-sensitivity C-reactive protein level higher than 1 mg/L (AUC 0.57), and 64% sensitivity and 50.2% specificity for a blood pressure higher than the age-, sex-, and height-specific 90th percentiles (AUC 0.56). Adolescents with a WHtR higher than 0.41 had an odds ratio of 2.46 (95% confidence interval 0.96-6.30) for having a HOMA-IR higher than 3.4. The WHtR cutoff to indicate metabolic risk for black South African adolescents is 0.41, which is lower than the proposed international cutoff of 0.5. The WHtR can be used for screening adolescents with components of the metabolic syndrome in intervention programs. Copyright © 2013 Elsevier Inc. All rights reserved.
[Diagnostic value of cardiac magnetic resonance in patients with acute viral myocarditis].
Ouyang, Haichun; Chen, Haixiong; Hu, Yunzhao; Wu, Yanxian; Li, Wensheng; Chen, Yuying; Cen, Yujian
2014-11-01
To assess the diagnostic value of cardiac magnetic resonance (CMR) in patients with acute viral myocarditis. Thirty patients with suspected acute viral myocarditis admitted in first people's hospital of Shunde from June 2011 to June 2013 were included in this prospective study. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of acute viral myocarditis were evaluated by clinical diagnosis. Diagnostic value among different scan methods and Lake Louise criteria were compared. Acute viral myocarditis was diagnosed in 63.33% (19/30) patients.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 57.89%, 72.73%, 78.57%, 50.00%, 63.33%, respectively by edema imaging (ER).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 63.64%, 78.95%, 63.64%, 73.33%, respectively using global relative enhancement (gRE).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 54.55%, 75.00%, 60.00%, 70.00%, respectively using late gadolinium enhancement (LGE) criteria.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 84.21%, 81.82%, 88.89%, 75.00%, 83.33% using Lake Louise criteria. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy using Lake Louise criteria were significantly higher than using ER, gRE, LGE alone(all P < 0.05).Specificity was higher using ER than using gRE and LGE (both P < 0.05). The sensitivity, NPV, and diagnostic accuracy were significantly higher using gRE than using ER (all P < 0.05) and was similar as using LGE (all P > 0.05). Cardiac magnetic resonance is an excellent imaging modality for the diagnosis of acute viral myocarditis.
The role of cone-beam breast-CT for breast cancer detection relative to breast density.
Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe
2017-12-01
To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (p<0.001). • Specificity was higher for mammography than CBBCT in both density types (p<0.05). • AUC was larger for mammography than CBBCT in both density types (p<0.001).
Van Hise, Christopher B; Greenslade, Jaimi H; Parsonage, William; Than, Martin; Young, Joanna; Cullen, Louise
2018-02-01
To externally validate a clinical decision rule incorporating heart fatty acid binding protein (h-FABP), high-sensitivity troponin (hs-cTn) and electrocardiogram (ECG) for the detection of acute myocardial infarction (AMI) on presentation to the Emergency Department. We also investigated whether this clinical decision rule improved identification of AMI over algorithms incorporating hs-cTn and ECG only. This study included data from 789 patients from the Brisbane ADAPT cohort and 441 patients from the Christchurch TIMI RCT cohort. The primary outcome was index AMI. Sensitivity, specificity, positive predictive value and negative predictive value were used to assess the diagnostic accuracy of the algorithms. 1230 patients were recruited, including 112 (9.1%) with AMI. The algorithm including h-FABP and hs-cTnT had 100% sensitivity and 32.4% specificity. The algorithm utilising h-FABP and hs-cTnI had similar sensitivity (99.1%) and higher specificity (43.4%). The hs-cTnI and hs-cTnT algorithms without h-FABP both had a sensitivity of 98.2%; a result that was not significantly different from either algorithm incorporating h-FABP. Specificity was higher for the hs-cTnI algorithm (68.1%) compared to the hs-cTnT algorithm (33.0%). The specificity of the algorithm incorporating hs-cTnI alone was also significantly higher than both of the algorithms incorporating h-FABP (p<0.01). For patients presenting to the Emergency Department with chest pain, an algorithm incorporating h-FABP, hs-cTn and ECG has high accuracy and can rule out up to 40% of patients. An algorithm incorporating only hs-cTn and ECG has similar sensitivity and may rule out a higher proportion of patients. Each of the algorithms can be used to safely identify patients as low risk for AMI on presentation to the Emergency Department. Copyright © 2017 The Canadian Society of Clinical Chemists. All rights reserved.
Hartman, Esther A R; van Royen-Kerkhof, Annet; Jacobs, Johannes W G; Welsing, Paco M J; Fritsch-Stork, Ruth D E
2018-03-01
To evaluate the performance in classifying systemic lupus erythematosus by the 2012 Systemic Lupus International Collaborating Clinics criteria (SLICC'12), versus the revised American College of Rheumatology criteria from 1997 (ACR'97) in adult and juvenile SLE patients. A systematic literature search was conducted in PubMed and Embase for studies comparing SLICC'12 and ACR'97 with clinical diagnosis. A meta-analysis was performed to estimate the sensitivity and specificity of SLICC'12 and ACR'97. To assess classification earlier in the disease by either set, sensitivity and specificity were compared for patients with disease duration <5years. Sensitivity and specificity of individual criteria items were also assessed. In adult SLE (nine studies: 5236 patients, 1313 controls), SLICC'12 has higher sensitivity (94.6% vs. 89.6%) and similar specificity (95.5% vs. 98.1%) compared to ACR'97. For juvenile SLE (four studies: 568 patients, 339 controls), SLICC'12 demonstrates higher sensitivity (99.9% vs. 84.3%) than ACR'97, but much lower specificity (82.0% vs. 94.1%). SLICC'12 classifies juvenile SLE patients earlier in disease course. Individual items contributing to diagnostic accuracy are low complement, anti-ds DNA and acute cutaneous lupus in SLICC'12, and the immunologic and hematologic disorder in ACR'97. Based on sensitivity and specificity SLICC'12 is best for adult SLE. Following the view that higher specificity, i.e. avoidance of false positives, is preferable, ACR'97 is best for juvenile SLE even if associated with lower sensitivity. Our results on the contribution of the individual items of SLICC'12 and ACR´97 may be of value in future efforts to update classification criteria. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Coburger, Jan; Scheuerle, Angelika; Kapapa, Thomas; Engelke, Jens; Thal, Dietmar Rudolf; Wirtz, Christian R; König, Ralph
2015-07-01
Linear array intraoperative ultrasound (lioUS) is an emerging technology for intracranial use. We evaluated sensitivity and specificity of lioUS to detect residual tumor in patients harboring a glioblastoma. After near total resection in 20 patients, residual tumor detection using lioUS, conventional intraoperative ultrasound (cioUS), and gadopentetic-diethylenetriamine penta-acetic acid (Gd-DTPA)-enhanced intraoperative MRI (iMRI) were compared. Sensitivity and specificity were calculated based on 68 navigated biopsies. Receiver operator characteristic (ROC) curves and correlation with histopathological findings of each imaging modality were calculated. Additionally, results were evaluated in the subgroup of recurrent disease (23 biopsies in 8 patients). Sensitivity of lioUS (76 %) was significantly higher compared with iMRI (55 %) and cioUS (24 %). Specificity of lioUS (58 %) was significantly lower than in cioUS (96 %), while there was no significant difference to iMRI (74 %). All imaging modalities correlated significantly with histopathological findings. In the subgroup of recurrent disease, sensitivity and specificity decreased in all modalities. However, cioUS showed significant lower values than iMRI and lioUS. In ROC curves, lioUS showed a higher area und the curve (AUC) in comparison with iMRI and cioUS. We found similar results in the subgroup of recurrent disease. Tumor detection using a lioUS is significantly superior to cioUS. Overall test performance in lioUS is comparable with results of iMRI. While, the latter has a higher specificity and a significantly lower sensitivity in comparison with lioUS.
Local Atopy in Childhood Adenotonsillar Hypertrophy.
Cho, Kyu-Sup; Kim, Seong Heon; Hong, Sung-Lyong; Lee, Jaeyoung; Mun, Sue Jean; Roh, Young Eun; Kim, Young Mi; Kim, Hye-Young
2018-05-01
Background Although the cause of adenotonsillar hypertrophy remains unknown, some studies have shown that allergy may be a risk factor. Purpose This study determined the levels of allergen-specific immunoglobulin E (sIgE) in the adenotonsillar tissues of children with adenotonsillar hypertrophy and evaluated the clinical significance of local atopy in adenotonsillar tissues. Methods We measured 21 types of specific immunoglobulin E in the serum and adenotonsillar tissues of 102 children with adenotonsillar hypertrophy and compared the sensitization patterns of the serum and local tissues. The patients were divided into three groups-atopy, local atopy, and nonatopy-according to the sensitization of serum and adenotonsillar tissues, and the clinical symptoms among the groups were analyzed. Results Seventy-two (70.6%) children with adenotonsillar hypertrophy were sensitized to more than one allergen in the serum and/or adenotonsillar tissue. Thirty (29.4%) children had no IgE positivity to any allergen in both serum and adenotonsillar tissues. Fifty-five (53.9%) were sensitized to at least one allergen in the serum. Seventy (68.6%) were sensitized to at least one allergen in the adenotonsillar tissue. Seventeen (36.2%) of 47 children with specific immunoglobulin E-negative serum had specific immunoglobulin E-positive adenotonsillar tissues. The rate of specific immunoglobulin E was significantly higher in local tissues than in serum. The rate of inhalant allergen specific immunoglobulin E was significantly higher in the adenoids than in the tonsils. However, the rate of food allergen specific immunoglobulin E was significantly higher in the tonsils than adenoids. The lifetime prevalence of asthma and allergic rhinitis, recent symptoms or treatment of allergic rhinitis, and severity of nasal symptoms (rhinorrhea, sneezing, and nasal itching) were significantly higher in children with local atopy than with nonatopy. Conclusions These results confirm that allergic response may be a risk factor for adenotonsillar hypertrophy. Local allergic inflammation may play an important role in childhood adenotonsillar hypertrophy, and local atopy in adenotonsillar tissues can cause respiratory allergic symptoms in children.
Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A
2013-03-01
To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.
Sensitivity and specificity of mammographic screening as practised in Vermont and Norway
Hofvind, S; Geller, B M; Skelly, J; Vacek, P M
2012-01-01
Objective The aim of this study was to examine the sensitivity and specificity of screening mammography as performed in Vermont, USA, and Norway. Methods Incident screening data from 1997 to 2003 for female patients aged 50–69 years from the Vermont Breast Cancer Surveillance System (116 996 subsequent screening examinations) and the Norwegian Breast Cancer Screening Program (360 872 subsequent screening examinations) were compared. Sensitivity and specificity estimates for the initial (based on screening mammogram only) and final (screening mammogram plus any further diagnostic imaging) interpretations were directly adjusted for age using 5-year age intervals for the combined Vermont and Norway population, and computed for 1 and 2 years of follow-up, which ended at the time of the next screening mammogram. Results For the 1-year follow-up, sensitivities for initial assessments were 82.0%, 88.2% and 92.5% for 1-, 2- and >2-year screening intervals, respectively, in Vermont (p=0.022). For final assessments, the values were 73.6%, 83.3% and 81.2% (p=0.047), respectively. For Norway, sensitivities for initial assessments were 91.0% and 91.3% (p=0.529) for 2- and >2-year intervals, and 90.7% and 91.3%, respectively, for final assessments (p=0.630). Specificity was lower in Vermont than in Norway for each screening interval and for all screening intervals combined, for both initial (90.6% vs 97.8% for all intervals; p<0.001) and final (98.8% vs 99.5% for all intervals; p<0.001) assessments. Conclusion Our study showed higher sensitivity and specificity in a biennial screening programme with an independent double reading than in a predominantly annual screening program with a single reading. Advances in knowledge This study demonstrates that higher recall rates and lower specificity are not always associated with higher sensitivity of screening mammography. Differences in the screening processes in Norway and Vermont suggest potential areas for improvement in the latter. PMID:22993383
Computer-aided interpretation approach for optical tomographic images
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.
2010-11-01
A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.
ERIC Educational Resources Information Center
Grunberg, Laura
2005-01-01
Summarizing the incomplete results of the United Nations Educational and Scientific Organization (UNESCO) program "Good Practice in Promoting Gender Equality in Higher Education," the author asks that any assessment of the progress made in the area of gender-sensitive education take regional specificities into account. The regional…
Nishii, Takashi; Tanaka, Hisashi; Nakanishi, Katsuyuki; Sugano, Nobuhiko; Miki, Hidenobu; Yoshikawa, Hideki
2005-08-01
Our objective was to assess the diagnostic ability of MDCT arthrography for acetabular and femoral cartilage lesions in patients with hip dysplasia. A disorder of the articular cartilage was evaluated in 20 hips of 18 patients with acetabular dysplasia who did not have osteoarthritis or who had early stage osteoarthritis before undergoing pelvic osteotomy surgery. The findings on fat-suppressed 3D fast spoiled gradient-echo MRI and MDCT arthrography of the hip were evaluated by two independent observers, and sensitivity, specificity, and accuracy were determined using arthroscopic findings as the standard of reference. Kappa values were calculated to quantify the level of interobserver agreement. The sensitivity and specificity for the detection of any cartilage disorder (grade 1 or higher) were (observer 1/observer 2) 49%/67% and 89%/76%, respectively, on MRI, and 67%/67% and 89%/82%, respectively, on CT arthrography. The sensitivity and specificity for the detection of cartilage lesions with substance loss (grade 2 or higher) were (observer 1/observer 2) 47%/53% and 92%/87%, respectively, on MRI, and 70%/79% and 93%/94%, respectively, on CT arthrography. CT arthrography provided significantly higher sensitivity in the detection of grade 2 or higher lesions than MRI for both observers. Interobserver agreement in the detection of grade 2 or higher cartilage lesions was moderate (kappa = 0.53) on MRI and substantial (kappa = 0.78) on CT. MDCT arthrography is a sensitive and reproducible method for assessing articular cartilage lesions with substance loss in patients with hip dysplasia.
Göbel, K; Erb, C
2013-02-01
The early detection of functional glaucoma damage plays an increasingly more central role in the diagnosis and treatment of glaucoma disease. Using selective perimetry detection of early glaucomatous defects is more likely and one of these methods is flicker perimetry with Pulsar. Flicker perimetry is used to analyze the temporal visual function in combination with spatial resolution and contrast sensitivity as opposed to standard automated perimetry which measures the differential light sensitivity with a non-specific stimulus. This study showed a higher sensitivity and specificity of Pulsar perimetry in comparison to achromatic perimetry in glaucoma patients.
Variation of a test's sensitivity and specificity with disease prevalence.
Leeflang, Mariska M G; Rutjes, Anne W S; Reitsma, Johannes B; Hooft, Lotty; Bossuyt, Patrick M M
2013-08-06
Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. We used data from 23 meta-analyses, each of which included 10-39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation.
Variation of a test’s sensitivity and specificity with disease prevalence
Leeflang, Mariska M.G.; Rutjes, Anne W.S.; Reitsma, Johannes B.; Hooft, Lotty; Bossuyt, Patrick M.M.
2013-01-01
Background: Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. Methods: We used data from 23 meta-analyses, each of which included 10–39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Results: Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. Interpretation: The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation. PMID:23798453
Williams, Javonda; Nelson-Gardell, Debra; Coulborn Faller, Kathleen; Tishelman, Amy; Cordisco-Steele, Linda
2014-01-01
Using data from a survey of perceptions of 932 child welfare professionals about the utility of extended assessments, the researchers constructed a scale to measure respondents' views about sensitivity (ensuring sexually abused children are correctly identified) and specificity (ensuring nonabused children are correctly identified) in child sexual abuse evaluations. On average, respondents scored high (valuing sensitivity) on the sensitivity versus specificity scale. Next, the researchers undertook bivariate analyses to identify independent variables significantly associated with the sensitivity versus specificity scale. Then those variables were entered into a multiple regression. Four independent variables were significantly related to higher sensitivity scores: encountering cases requiring extended assessments, valuing extended assessments among scarce resources, less concern about proving cases in court, and viewing the goal of extended assessments as understanding needs of child and family (adjusted R2 = .34).
Wang, Fen; Chang, Cai; Chen, Min; Gao, Yi; Chen, Ya-Ling; Zhou, Shi-Chong; Li, Jia-Wei; Zhi, Wen-Xiang
2018-03-01
We aimed to investigate the diagnostic performance of shear wave elastography (SWE) combined with conventional ultrasonography (US) for differentiating between benign and malignant thyroid nodules of different sizes. A total of 445 thyroid nodules from 445 patients were divided into 3 groups based on diameter (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm). The mean elasticity index of the whole lesion was automatically calculated, and the threshold for differentiation between benign and malignant nodules was constructed by a receiver operating characteristic curve analysis. Diagnostic performances of conventional US and SWE were compared by using pathologic results as reference standards. The mean elasticity was significantly higher in malignant versus benign nodules for all size groups. The differences in mean elasticity in the size groups were not statistically significant for malignant or benign nodules. The specificity of US combined with SWE for group 1 was significantly higher than that for groups 2 and 3 (77.8% versus 62.9% and 53.3%; P < .05), and compared with group 1, the sensitivity was significantly higher for groups 2 and 3 (92.4% and 94.3% versus 80.7%; P < .05). When SWE was added, the specificity increased and the sensitivity and diagnostic accuracy decreased for group 1, and the sensitivity increased and the specificity decreased for groups 2 and 3; however, the differences were not significant. Combined with SWE, US yielded higher specificity for nodules of 10 mm and smaller and higher sensitivity for nodules larger than 10 mm. © 2017 by the American Institute of Ultrasound in Medicine.
Khedmat, S; Rouhi, N; Drage, N; Shokouhinejad, N; Nekoofar, M H
2012-11-01
To compare the accuracy of digital radiography (DR), multidetector computed tomography (MDCT) and cone beam computed tomography (CBCT) in detecting vertical root fractures (VRF) in the absence and presence of gutta-percha root filling. The root canals of 100 extracted human single-rooted teeth were prepared and randomly divided into four groups: two experimental groups with artificially fractured root and two intact groups as controls. In one experimental and one control group, a size 40, 0.04 taper gutta-percha cone was inserted in the root canals. Then DR, MDCT and CBCT were performed and the images evaluated. Statistical analyses of sensitivity, specificity and accuracy of each imaging technique in the presence and absence of gutta-percha were calculated and compared. In the absence of gutta-percha, the specificity of DR, MDCT and CBCT was similar. CBCT was the most accurate and sensitive imaging technique (P < 0 .05). In the presence of gutta-percha, the accuracy of MDCT was higher than the other imaging techniques (P < 0.05). The sensitivity of CBCT and MDCT was significantly higher than that of DR (P < 0.05), whereas CBCT was the least specific technique. Under the conditions of this ex vivo study, CBCT was the most sensitive imaging technique in detecting vertical root fracture. The presence of gutta-percha reduced the accuracy, sensitivity and specificity of CBCT but not MDCT. The sensitivity of DR was reduced in the presence of gutta-percha. The use of MDCT as an alternative technique may be recommended when VRF are suspected in root filled teeth. However, as the radiation dose of MDCT is higher than CBCT, the technique could be considered at variance with the principles of ALARA. © 2012 International Endodontic Journal.
McDonnell, Liam A; Heeren, Ron M A; de Lange, Robert P J; Fletcher, Ian W
2006-09-01
To expand the role of high spatial resolution secondary ion mass spectrometry (SIMS) in biological studies, numerous developments have been reported in recent years for enhancing the molecular ion yield of high mass molecules. These include both surface modification, including matrix-enhanced SIMS and metal-assisted SIMS, and polyatomic primary ions. Using rat brain tissue sections and a bismuth primary ion gun able to produce atomic and polyatomic primary ions, we report here how the sensitivity enhancements provided by these developments are additive. Combined surface modification and polyatomic primary ions provided approximately 15.8 times more signal than using atomic primary ions on the raw sample, whereas surface modification and polyatomic primary ions yield approximately 3.8 and approximately 8.4 times more signal. This higher sensitivity is used to generate chemically specific images of higher mass biomolecules using a single molecular ion peak.
Efficacy of functional movement screening for predicting injuries in coast guard cadets.
Knapik, Joseph J; Cosio-Lima, Ludimila M; Reynolds, Katy L; Shumway, Richard S
2015-05-01
Functional movement screening (FMS) examines the ability of individuals to perform highly specific movements with the aim of identifying individuals who have functional limitations or asymmetries. It is assumed that individuals who can more effectively accomplish the required movements have a lower injury risk. This study determined the ability of FMS to predict injuries in the United States Coast Guard (USCG) cadets. Seven hundred seventy male and 275 female USCG freshman cadets were administered the 7 FMS tests before the physically intense 8-week Summer Warfare Annual Basic (SWAB) training. Physical training-related injuries were recorded during SWAB training. Cumulative injury incidence was calculated at various FMS cutpoint scores. The ability of the FMS total score to predict injuries was examined by calculating sensitivity and specificity. Determination of the FMS cutpoint that maximized specificity and sensitivity was determined from the Youden's index (sensitivity + specificity - 1). For men, FMS scores ≤ 12 were associated with higher injury risk than scores >12; for women, FMS scores ≤ 15 were associated with higher injury risk than scores >15. The Youden's Index indicated that the optimal FMS cutpoint was ≤ 11 for men (22% sensitivity, 87% specificity) and ≤ 14 for women (60% sensitivity, 61% specificity). Functional movement screening demonstrated moderate prognostic accuracy for determining injury risk among female Coast Guard cadets but relatively low accuracy among male cadets. Attempting to predict injury risk based on the FMS test seems to have some limited promise based on the present and past investigations.
Limits to Sensitivity in Laser Enhanced Ionization.
ERIC Educational Resources Information Center
Travis, J. C.
1982-01-01
Laser enhanced ionization (LEI) occurs when a tunable dye laser is used to excite a specific atomic population in a flame. Explores the origin of LEI's high sensitivity and identifies possible avenues to higher sensitivity by describing instrument used and experimental procedures and discussing ion formation/detection. (Author/JN)
Dibble, Elizabeth H; Lourenco, Ana P; Baird, Grayson L; Ward, Robert C; Maynard, A Stanley; Mainiero, Martha B
2018-01-01
To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT). This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012-27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively. There were 59 AD patients and 59 controls for 1,888 observations (59 × 2 (cases and controls) × 2 breasts × 2 imaging techniques × 4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p = .001. DBT achieved higher sensitivity (.59 vs. .32), p < .001; specificity remained high (>.90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values. DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD. • Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion. • Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion. • Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.
Dang, T D; Tang, M L K; Koplin, J J; Licciardi, P V; Eckert, J K; Tan, T; Gurrin, L C; Ponsonby, A-L; Dharmage, S C; Allen, K J
2013-10-01
Sensitization to food allergens indicates the production of food-specific IgE; however, sensitization is not a definite indicator of allergic reaction upon ingestion (N Engl J Med, 344, 2001, 30: J Allergy Clin Immunol, 120, 2007, 491). Currently, food challenge is the best approach to identify the presence or absence of allergy. While 95% positive predictive values (PPVs) thresholds for sIgE can assist with identifying increased likelihood of allergy among those who are sensitized, there are no specific biological markers that differentiate between allergic and sensitized individuals. To determine whether plasma serum cytokine profiles predict (i) sensitization to peanut and egg and (ii) food allergy among sensitized infants. Peanut-sensitized (PT) and egg-sensitized 14-month-old infants and nonsensitized controls enrolled in HealthNuts, a population-based study of food allergy, underwent an oral food challenge (OFC). Blood was collected within 1 h after OFC. Serum levels of Th1, Th2 and regulatory cytokines were determined in allergic (n = 79), sensitized (n = 40) and nonsensitized, nonallergic (n = 37) infants by multiplex assay. Food-sensitized infants had significantly higher plasma IL-4, IL-13, IL-12p70 and lower IL-10 levels compared to nonsensitized infants. IL-10 and IL-6 levels were significantly higher in sensitized compared with allergic infants. Egg-allergic infants had significantly higher IL-13 and IL-12p70 levels compared to peanut-allergic (PA) infants. Levels of Th2-related cytokines in plasma are higher in food-sensitized infants, irrespective of clinical food allergy status. In contrast, IL-10 levels appear to predict food allergy among sensitized infants. Differences in IL-13 and IL-12p70 between egg- and peanut-allergic infants could help explain the different resolution rates of the allergies. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L
2016-01-01
Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis.
Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L.
2016-01-01
Background Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. Objective To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Methods Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Results Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). Conclusion The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis. PMID:27171380
Bodien, Yelena G; Carlowicz, Cecilia A; Chatelle, Camille; Giacino, Joseph T
2016-03-01
To describe the sensitivity and specificity of Coma Recovery Scale-Revised (CRS-R) total scores in detecting conscious awareness. Data were retrospectively extracted from the medical records of patients enrolled in a specialized disorders of consciousness (DOC) program. Sensitivity and specificity analyses were completed using CRS-R-derived diagnoses of minimally conscious state (MCS) or emerged from minimally conscious state (EMCS) as the reference standard for conscious awareness and the total CRS-R score as the test criterion. A receiver operating characteristic curve was constructed to demonstrate the optimal CRS-R total cutoff score for maximizing sensitivity and specificity. Specialized DOC program. Patients enrolled in the DOC program (N=252, 157 men; mean age, 49y; mean time from injury, 48d; traumatic etiology, n=127; nontraumatic etiology, n=125; diagnosis of coma or vegetative state, n=70; diagnosis of MCS or EMCS, n=182). Not applicable. Sensitivity and specificity of CRS-R total scores in detecting conscious awareness. A CRS-R total score of 10 or higher yielded a sensitivity of .78 for correct identification of patients in MCS or EMCS, and a specificity of 1.00 for correct identification of patients who did not meet criteria for either of these diagnoses (ie, were diagnosed with vegetative state or coma). The area under the curve in the receiver operating characteristic curve analysis is .98. A total CRS-R score of 10 or higher provides strong evidence of conscious awareness but resulted in a false-negative diagnostic error in 22% of patients who demonstrated conscious awareness based on CRS-R diagnostic criteria. A cutoff score of 8 provides the best balance between sensitivity and specificity, accurately classifying 93% of cases. The optimal total score cutoff will vary depending on the user's objective. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Park, Su San; Lee, Ju Yul; Cho, Sung-Il
2007-07-01
We investigated the validity of the dipstick method (Mossman Associates Inc. USA) and the expired CO method to distinguish between smokers and nonsmokers. We also elucidated the related factors of the two methods. This study included 244 smokers and 50 ex-smokers, recruited from smoking cessation clinics at 4 local public health centers, who had quit for over 4 weeks. We calculated the sensitivity, specificity and Kappa coefficient of each method for validity. We obtained ROC curve, predictive value and agreement to determine the cutoff of expired air CO method. Finally, we elucidated the related factors and compared their effect powers using the standardized regression coefficient. The dipstick method showed a sensitivity of 92.6%, specificity of 96.0% and Kappa coefficient of 0.79. The best cutoff value to distinguish smokers was 5-6 ppm. At 5 ppm, the expired CO method showed a sensitivity of 94.3%, specificity of 82.0% and Kappa coefficient of 0.73. And at 6 ppm, sensitivity, specificity and Kappa coefficient were 88.5%, 86.0% and 0.64, respectively. Therefore, the dipstick method had higher sensitivity and specificity than the expired CO method. The dipstick and expired CO methods were significantly increased with increasing smoking amount. With longer time since the last smoking, expired CO showed a rapid decrease after 4 hours, whereas the dipstick method showed relatively stable levels for more than 4 hours. The dipstick and expired CO methods were both good indicators for assessing smoking status. However, the former showed higher sensitivity and specificity and stable levels over longer hours after smoking, compared to the expired CO method.
Quantitative assessment of serum-specific IgE in the diagnosis of human cystic echinococcosis.
Marinova, I; Nikolov, G; Michova, A; Kurdova, R; Petrunov, B
2011-07-01
Anti-Echinococcus serum immunoglobulin (Ig)E was assessed by the ImmunoCAP system and compared with anti-Echinococcus serum IgG assessed by enzyme-linked immunosorbent assay (ELISA) and Western blot. The ImmunoCAP system revealed very high specificity (one false positive of 110 healthy individuals), low cross-reactivity (one false positive of 58 patients with other diseases) and decreased sensitivity (73.55%). Receiver operating characteristic analysis displayed a beneficial diagnostic value with high accuracy. Comparison of the ImmunoCAP system with ELISA and Western blot showed significantly higher specificity and significantly lower cross-reactivity compared with the ELISA. Examination of sera from 155 patients with cystic echinococcosis (CE) showed varying levels of anti-Echinococcus IgE (range, 0.01-118.33 kUA/L). However, most samples had moderately elevated IgE levels. Analysis of serum-specific IgE revealed significantly higher sensitivity of the ImmunoCAP system and significantly higher antibody levels in hepatic CE compared with pulmonary CE. © 2011 Blackwell Publishing Ltd.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-10-13
The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.
Gene expression analysis using a highly sensitive DNA microarray for colorectal cancer screening.
Koga, Yoshikatsu; Yamazaki, Nobuyoshi; Takizawa, Satoko; Kawauchi, Junpei; Nomura, Osamu; Yamamoto, Seiichiro; Saito, Norio; Kakugawa, Yasuo; Otake, Yosuke; Matsumoto, Minori; Matsumura, Yasuhiro
2014-01-01
Half of all patients with small, right-sided, non-metastatic colorectal cancer (CRC) have negative results for the fecal occult blood test (FOBT). In the present study, the usefulness of CRC screening with a highly sensitive DNA microarray was evaluated in comparison with that by FOBT using fecal samples. A total of 53 patients with CRC and 61 healthy controls were divided into "training" and "validation sets". For the gene profiling, total RNA extracted from 0.5 g of feces was hybridized to a highly sensitive DNA chip. The expressions of 43 genes were significantly higher in the patients with CRC than in healthy controls (p<0.05). In the training set, the sensitivity and specificity of the DNA chip assay using six genes were 85.4% and 85.2%, respectively. On the other hand, in the validation set, the sensitivity and specificity of the DNA chip assay were 85.2% and 85.7%, respectively. The sensitivities of the DNA chip assay were higher than those of FOBT in cases of the small, right-sided, early-CRC, tumor invading up to the muscularis propria (i.e. surface tumor) subgroups. In particular, the sensitivities of the DNA chip assay in the surface tumor and early-CRC subgroups were significantly higher than those of FOBT (p=0.023 and 0.019, respectively.). Gene profiling assay using a highly sensitive DNA chip was more effective than FOBT at detecting patients with small, right-sided, surface tumor, and early-stage CRC.
Orlando Júnior, Nilton; de Souza Leão, Marcos George; de Oliveira, Nelson Henrique Carvalho
2015-01-01
Objectives To ascertain the sensitivity, specificity, accuracy and concordance of the physical examination (PE) and magnetic resonance imaging (MRI) in comparison with arthroscopy, in diagnosing knee injuries. Methods Prospective study on 72 patients, with evaluation and comparison of PE, MRI and arthroscopic findings, to determine the concordance, accuracy, sensitivity and specificity. Results PE showed sensitivity of 75.00%, specificity of 62.50% and accuracy of 69.44% for medial meniscal (MM) lesions, while it showed sensitivity of 47.82%, specificity of 93.87% and accuracy of 79.16% for lateral meniscal (LM) lesions. For anterior cruciate ligament (ACL) injuries, PE showed sensitivity of 88.67%, specificity of 94.73% and accuracy of 90.27%. For MM lesions, MRI showed sensitivity of 92.50%, specificity of 62.50% and accuracy of 69.44%, while for LM injuries, it showed sensitivity of 65.00%, specificity of 88.46% and accuracy of 81.94%. For ACL injuries, MRI showed sensitivity of 86.79%, specificity of 73.68% and accuracy of 83.33%. For ACL injuries, the best concordance was with PE, while for MM and LM lesions, it was with MRI (p < 0.001). Conclusions Meniscal and ligament injuries can be diagnosed through careful physical examination, while requests for MRI are reserved for complex or doubtful cases. PE and MRI used together have high sensitivity for ACL and MM lesions, while for LM lesions the specificity is higher. Level of evidence II – Development of diagnostic criteria on consecutive patients (with universally applied reference “gold” standard). PMID:27218085
Chang, Ming-Chu; Liang, Po-Chin; Jan, I-Shiow; Yang, Ching-Yao; Tien, Yu-Wen; Wei, Shu-Chen; Wong, Jau-Min; Chang, Yu-Ting
2014-08-18
The International Consensus Diagnostic Criteria (ICDC) designed to diagnosis autoimmune pancreatitis (AIP) has been proposed recently. The diagnostic performance of ICDC has not been previously evaluated in diffuse-type and focal-type AIP, respectively, in comparison with the revised HISORt and Asian criteria in Taiwan. Prospective, consecutive patient cohort. Largest tertiary referred centre hospital managing pancreatic disease in Taiwan. 188 patients with AIP and 130 with tissue proofed pancreatic adenocarcinoma were consecutively recruited. The ICDC, as well as revised HISORt and Asian criteria, was applied for each participant. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in diffuse-type and focal-type AIP. Sensitivity, specificity and accuracy. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in AIP and focal-type AIP. The sensitivity, specificity and accuracy of ICDC for all AIP were the best: 89.4%, 100% and 93.7%, respectively, in these three criteria. The sensitivity, specificity and accuracy of ICDC for focal-type AIP (84.9%, 100% and 93.8%) were also the best among these three criteria. The area under the curve of receiver-operator characteristic of ICDC was 0.95 (95% CI 0.92 to 0.97) in all AIP and 0.93 (95% CI 0.88 to 0.97) in focal-type AIP. The sensitivity, specificity and accuracy of ICDC are higher than the revised HISORt and Asian criteria. The sensitivity, specificity and accuracy of each criterion are higher in diffuse-type AIP compared with focal-type AIP. Under the same specificity, the sensitivity and accuracy of ICDC are higher than other diagnostic criteria in focal-type AIP. ICDC has better diagnostic performance compared with previously proposed diagnostic criteria in diffuse-type and focal-type AIP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Cross-national comparison of screening mammography accuracy measures in U.S., Norway, and Spain.
Domingo, Laia; Hofvind, Solveig; Hubbard, Rebecca A; Román, Marta; Benkeser, David; Sala, Maria; Castells, Xavier
2016-08-01
To compare accuracy measures for mammographic screening in Norway, Spain, and the US. Information from women aged 50-69 years who underwent mammographic screening 1996-2009 in the US (898,418 women), Norway (527,464), and Spain (517,317) was included. Screen-detected cancer, interval cancer, and the false-positive rates, sensitivity, specificity, positive predictive value (PPV) for recalls (PPV-1), PPV for biopsies (PPV-2), 1/PPV-1 and 1/PPV-2 were computed for each country. Analyses were stratified by age, screening history, time since last screening, calendar year, and mammography modality. The rate of screen-detected cancers was 4.5, 5.5, and 4.0 per 1000 screening exams in the US, Norway, and Spain respectively. The highest sensitivity and lowest specificity were reported in the US (83.1 % and 91.3 %, respectively), followed by Spain (79.0 % and 96.2 %) and Norway (75.5 % and 97.1 %). In Norway, Spain and the US, PPV-1 was 16.4 %, 9.8 %, and 4.9 %, and PPV-2 was 39.4 %, 38.9 %, and 25.9 %, respectively. The number of women needed to recall to detect one cancer was 20.3, 6.1, and 10.2 in the US, Norway, and Spain, respectively. Differences were found across countries, suggesting that opportunistic screening may translate into higher sensitivity at the cost of lower specificity and PPV. • Positive predictive value is higher in population-based screening programmes in Spain and Norway. • Opportunistic mammography screening in the US has lower positive predictive value. • Screening settings in the US translate into higher sensitivity and lower specificity. • The clinical burden may be higher for women screened opportunistically.
Bayer, Thomas; Fries, Simon; Schweizer, Andreas; Schöffl, Isabelle; Janka, Rolf; Bongartz, Georg
2015-01-01
The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position.
The influence of viewing conditions on radiological diagnosis of periapical inflammation.
Patel, N; Rushton, V E; Macfarlane, T V; Horner, K
2000-07-08
To determine the effect of viewing conditions upon diagnosis of early periapical inflammatory pathosis on intra-oral radiographs, and to examine the effect of observer experience upon diagnostic performance in this task. 50 observers examined 18 periapical radiographs using three different viewing conditions (room lighting; viewing box; viewing box with x2 magnification and masking). Their diagnoses were compared with an 'expert' diagnosis provided by repeated viewings of the films by two dental radiologists. Sensitivities and specificities were determined. When 'ideal' viewing conditions were used, optimal sensitivity (78%) and specificity (78%) were obtained. Use of a viewing box was associated with significantly higher specificity than the use of room lighting (P = 0.0016). Use of masking and x2 magnification was associated with significantly higher sensitivity than a viewing box alone (P = 0.004). There were few significant differences in diagnostic performance between observers, but qualified dental staff had significantly higher specificities than 4th year (P = 0.01) and 5th year (P = 0.01) students when a viewing box was used alone. This study on early periapical inflammatory pathosis gives support to guidelines which recommend the use of a viewing box, x2 magnification and masking for interpreting intra-oral radiographs. It also suggests that observer experience may influence interpretation of early periapical pathosis.
Zur, RM; Roy, LM; Ito, S; Beyene, J; Carew, C; Ungar, WJ
2016-01-01
Thiopurine S-methyltransferase (TPMT) deficiency increases the risk of serious adverse events in persons receiving thiopurines. The objective was to synthesize reported sensitivity and specificity of TPMT phenotyping and genotyping using a latent class hierarchical summary receiver operating characteristic meta-analysis. In 27 studies, pooled sensitivity and specificity of phenotyping for deficient individuals was 75.9% (95% credible interval (CrI), 58.3–87.0%) and 98.9% (96.3–100%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 90.4% (79.1–99.4%) and 100.0% (99.9–100%), respectively. For individuals with deficient or intermediate activity, phenotype sensitivity and specificity was 91.3% (86.4–95.5%) and 92.6% (86.5–96.6%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 88.9% (81.6–97.5%) and 99.2% (98.4–99.9%), respectively. Genotyping has higher sensitivity as long as TPMT*2 and TPMT*3 are tested. Both approaches display high specificity. Latent class meta-analysis is a useful method for synthesizing diagnostic test performance data for clinical practice guidelines. PMID:27217052
Jurate, Kondrackiene; Rimantas, Zalinkevicius; Jolanta, Sumskiene; Vladas, Gintautas; Limas, Kupcinskas
2017-01-01
Intrahepatic cholestasis of pregnancy (ICP) is linked with increased risk of fetal complications. An accurate diagnostic test is needed to diagnose this disorder on time. We aimed to assess sensitivity and specificity of laboratory tests used for diagnosis of intrahepatic cholestasis of pregnancy and determine more reliable cut-off values of transaminases. Sixty one symptomatic patients with ICP and 29 healthy pregnant women were included in the retrospective analysis. ICP patients had higher total bile acids (TBA) levels than healthy women (32 vs. 6; P < 0.0001) due to increase in cholic acid (CA) and chenodeoxycholic acid (CDCA). CA/CDCA ratio was significantly higher in ICP patients compared to healthy pregnant women (1.13 vs. 0.68; P < 0.00002). TBA, CA, CDCA and CA/CDCA ratio demonstrate the following sensitivity (94%, 96%, 89%, 71.9%) and specificity (63%, 63%, 59%, 79.3%, respectively) for ICP diagnosis. Lowering cut-off values for ALT (31 U/L) and AST (30 U/L) resulted only in minimal increase of sensitivity to 92.2% vs. 90.1% for ALT and to 92.2%, vs. 90.6% for AST. The present study did not reveal any single specific and sensitive marker for reliable diagnosis of ICP. Establishment of lower cut-off values for transaminases activity might only minimally increase the accuracy of diagnosing ICP.
Ramilo, Andrea; Navas, J Ignacio; Villalba, Antonio; Abollo, Elvira
2013-05-27
Bonamia ostreae and B. exitiosa have caused mass mortalities of various oyster species around the world and co-occur in some European areas. The World Organisation for Animal Health (OIE) has included infections with both species in the list of notifiable diseases. However, official methods for species-specific diagnosis of either parasite have certain limitations. In this study, new species-specific conventional PCR (cPCR) and real-time PCR techniques were developed to diagnose each parasite species. Moreover, a multiplex PCR method was designed to detect both parasites in a single assay. The analytical sensitivity and specificity of each new method were evaluated. These new procedures were compared with 2 OIE-recommended methods, viz. standard histology and PCR-RFLP. The new procedures showed higher sensitivity than the OIE recommended ones for the diagnosis of both species. The sensitivity of tests with the new primers was higher using oyster gills and gonad tissue, rather than gills alone. The lack of a 'gold standard' prevented accurate estimation of sensitivity and specificity of the new methods. The implementation of statistical tools (maximum likelihood method) for the comparison of the diagnostic tests showed the possibility of false positives with the new procedures, although the absence of a gold standard precluded certainty. Nevertheless, all procedures showed negative results when used for the analysis of oysters from a Bonamia-free area.
Sensitivity and Specificity in Three Measures of Depression Among Mexican American Women.
Valencia-Garcia, Dellanira; Bi, Xiaoyu; Ayón, Cecilia
2017-06-01
This paper examined the prevalence of depressive symptomotology among women of Mexican ancestry (N = 205), over the age of 18, of diverse incomes and nativity. We examined differences in rates of diagnosis by Spanish/English preference and the sensitivity and specificity of three common measures: the Patient Health Questionnaire (PHQ9), the Kessler Psychological Distress Scale (K-10), and depression questions from the Composite International Diagnostic Interview, Short Form (MDD CIDI-SF); PHQ9 was used as the "gold standard" measure. Results indicated 18-32 % of participants met criteria for depression with higher rates found among Spanish preference participants. The K-10 had significantly higher sensitivity (0.81) but lower specificity (0.79) than the MDD CIDI-SF items (0.57 and 0.89, respectively). This study suggests that the K-10 and MDD CIDI-SF measures are complementary to each other for screening of depressive symptomatology. Implications for cultural and linguistic assessment of depression are further discussed.
ERIC Educational Resources Information Center
Honda, Hideo; Shimizu, Yasuo; Nitto, Yukari; Imai, Miho; Ozawa, Takeshi; Iwasa, Mitsuaki; Shiga, Keiko; Hira, Tomoko
2009-01-01
Background: For early detection of autism, it is difficult to maintain an efficient level of sensitivity and specificity based on observational data from a single screening. The Extraction and Refinement (E&R) Strategy utilizes a public children's health surveillance program to produce maximum efficacy in early detection of autism. In the…
Accuracy of Carotid Duplex Criteria in Diagnosis of Significant Carotid Stenosis in Asian Patients.
Dharmasaroja, Pornpatr A; Uransilp, Nattaphol; Watcharakorn, Arvemas; Piyabhan, Pritsana
2018-03-01
Extracranial carotid stenosis can be diagnosed by velocity criteria of carotid duplex. Whether they are accurately applied to define severity of internal carotid artery (ICA) stenosis in Asian patients needs to be proved. The purpose of this study was to evaluate the accuracy of 2 carotid duplex velocity criteria in defining significant carotid stenosis. Carotid duplex studies and magnetic resonance angiography were reviewed. Criteria 1 was recommended by the Society of Radiologists in Ultrasound; moderate stenosis (50%-69%): peak systolic velocity (PSV) 125-230 cm/s, diastolic velocity (DV) 40-100 cm/s; severe stenosis (>70%): PSV greater than 230 cm/s, DV greater than 100 cm/s. Criteria 2 used PSV greater than 140 cm/s, DV less than 110 cm/s to define moderate stenosis (50%-75%) and PSV greater than 140 cm/s, DV greater than 110 cm/s for severe stenosis (76%-95%). A total of 854 ICA segments were reviewed. There was moderate stenosis in 72 ICAs, severe stenosis in 50 ICAs, and occlusion in 78 ICAs. Criteria 2 had slightly lower sensitivity, whereas higher specificity and accuracy than criteria 1 were observed in detecting moderate stenosis (criteria 1: sensitivity 95%, specificity 83%, accuracy 84%; criteria 2: sensitivity 92%, specificity 92%, and accuracy 92%). However, in detection of severe ICA stenosis, no significant difference in sensitivity, specificity, and accuracy was found (criteria 1: sensitivity 82%, specificity 99.57%, accuracy 98%; criteria 2: sensitivity 86%, specificity 99.68%, and accuracy 99%). In the subgroup of moderate stenosis, the criteria using ICA PSV greater than 140 cm/s had higher specificity and accuracy than the criteria using ICA PSV 125-230 cm/s. However, there was no significant difference in detection of severe stenosis or occlusion of ICA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Aung, Kyaw L; Donald, Emma; Ellison, Gillian; Bujac, Sarah; Fletcher, Lynn; Cantarini, Mireille; Brady, Ged; Orr, Maria; Clack, Glen; Ranson, Malcolm; Dive, Caroline; Hughes, Andrew
2014-05-01
BRAF mutation testing from circulating free DNA (cfDNA) using the amplification refractory mutation testing system (ARMS) holds potential as a surrogate for tumor mutation testing. Robust assay validation is needed to establish the optimal clinical matrix for measurement and cfDNA-specific mutation calling criteria. Plasma- and serum-derived cfDNA samples from 221 advanced melanoma patients were analyzed for BRAF c.1799T>A (p.V600E) mutation using ARMS in two stages in a blinded fashion. cfDNA-specific mutation calling criteria were defined in stage 1 and validated in stage 2. cfDNA concentrations in serum and plasma, and the sensitivities and specificities of BRAF mutation detection in these two clinical matrices were compared. Sensitivity of BRAF c.1799T>A (p.V600E) mutation detection in cfDNA was increased by using mutation calling criteria optimized for cfDNA (these criteria were adjusted from those used for archival tumor biopsies) without compromising specificity. Sensitivity of BRAF mutation detection in serum was 44% (95% CI, 35% to 53%) and in plasma 52% (95% CI, 43% to 61%). Specificity was 96% (95% CI, 90% to 99%) in both matrices. Serum contains significantly higher total cfDNA than plasma, whereas the proportion of tumor-derived mutant DNA was significantly higher in plasma. Using mutation calling criteria optimized for cfDNA improves sensitivity of BRAF c.1799T>A (p.V600E) mutation detection. The proportion of tumor-derived cfDNA in plasma was significantly higher than in serum. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Clay, Timothy A; Gifford, Matthew E
2017-02-01
Thermal adaptation predicts that thermal sensitivity of physiological traits should be optimized to thermal conditions most frequently experienced. Furthermore, thermodynamic constraints predict that species with higher thermal optima should have higher performance maxima and narrower performance breadths. We tested these predictions by examining the thermal sensitivity of energy assimilation between populations within two species of terrestrial-lungless salamanders, Plethodon albagula and P. montanus. Within P. albagula, we examined populations that were latitudinally separated by >450km. Within P. montanus, we examined populations that were elevationally separated by >900m. Thermal sensitivity of energy assimilation varied substantially between populations of P. albagula separated latitudinally, but did not vary between populations of P. montanus separated elevationally. Specifically, in P. albagula, the lower latitude population had a higher thermal optimum, higher maximal performance, and narrower performance breadth compared to the higher latitude population. Furthermore, across all individuals as thermal optima increased, performance maxima also increased, providing support for the theory that "hotter is better". Copyright © 2016 Elsevier Ltd. All rights reserved.
Carlsten, Chris; Dimich-Ward, Helen; Ferguson, Alexander; Becker, Allan; Dybuncio, Anne; Chan-Yeung, Moira
2011-02-01
The operating characteristics of PC(20) values used as cut-offs to define airway hyperresponsiveness, as it informs the diagnosis of asthma in children, are poorly understood. We examine data from a unique cohort to inform this concern. Determine the sensitivity and specificity of incremental PC(20) cut-offs for allergist-diagnosed asthma. Airway reactivity at age 7 was assessed in children within a birth cohort at high risk for asthma; PC(20) for methacholine was determined by standard technique including interpolation. The diagnosis of asthma was considered by the pediatric allergist without knowledge of the methacholine challenge results. Sensitivity and specificity were calculated using a cross-tabulation of asthma diagnosis with incremental PC(20) cut-off values, from 1.0 to 8.0 mg/ml, and plotted as receiver operator characteristic (ROC) curves. The "optimal" cut-off was defined as that PC(20) conferring maximal value for sensitivity plus specificity while the "balanced" cut-off was defined as that PC(20) at which sensitivity and specificity were most equal. 70/348 children (20.1%) were diagnosed with asthma. The optimal and balanced PC(20) cut-offs, both for all children and for females alone, were respectively 3 mg/ml (sensitivity 80.0%, specificity 49.1%) and 2 mg/ml (sensitivity 63.1%, specificity 64.7%). For males alone, the "optimal" and "balanced" PC(20) cut-offs were both 2 mg/ml. For this cohort of 7-year olds at high risk for asthma, methacholine challenge testing using a cut-off value of PC(20) 3 mg/ml conferred the maximal sum of specificity plus sensitivity. For contexts in which higher sensitivity or specificity is desired, other cut-offs may be preferred. Copyright © 2011 Wiley-Liss, Inc.
The measurement of boredom: differences between existing self-report scales.
Mercer-Lynn, Kimberley B; Flora, David B; Fahlman, Shelley A; Eastwood, John D
2013-10-01
There are two commonly used measures of boredom: the Boredom Proneness Scale (BPS) and the Boredom Susceptibility Scale (ZBS). Although both were designed to measure the propensity to experience boredom (i.e., trait boredom), there are reasons to think they may not measure the same construct. The present research sought to evaluate this proposition in several stages. Specifically, relationships between the BPS, ZBS, and important causal (Study 1, N = 837), correlational (Study 2, N = 233), and outcome variables (Study 3, N = 137) were examined in university students. Taken together, results support the notion that the BPS and ZBS do not measure the same construct. Specifically, higher BPS scores were associated with higher levels of neuroticism, experiential avoidance, attentional and nonplanning impulsivity, anxiety, depression, dysphoria, and emotional eating. Conversely, higher ZBS scores were associated with higher levels of motor impulsivity, sensitivity to reward, gambling, and alcohol use and lower levels of neuroticism, experiential avoidance, and sensitivity to punishment.
Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.
2015-01-01
OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-01-01
The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440
Kumar, Raj; Gupta, Nitesh; Kanuga, Jayesh; Kanuga, Mansi
2015-01-01
Skin prick testing (SPT) is the 'gold standard' in the assessment of allergic sensitivity to inhalant allergens. Serum-specific immunoglobulin E (SSIgE) measurement is a complementary test. SPT is performed with antigen extracts from India while SSIgE utilises extracts derived from European antigens. To evaluate the performance of allergic assessment by SSIgE against cockroach, housefly and mosquito aeroallergens which are frequently implicated in driving respiratory allergies in India considering SPT as the 'gold standard'. Twenty patients (mean age 28.5 years; range 15-50 years) diagnosed to have bronchial asthma and/or rhinitis underwent SPT. The SSIgE levels were obtained at the same visit. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SSIgE testing were calculated using SPT as the 'gold standard'. The correlation between SPT grading and SSIgE levels was also evaluated. The sensitivity of SSIgE testing to each of the 3 aero-allergens was > 85%. The PPV of cockroach and mosquito SSIgE was > 85%; housefly SSIgE had PPV of 68.7%. The two tests were in agreement in 85% (cockroach), 90% (mosquito) and 55% (housefly). There was a significant correlation between the grades of SPT reactions and SSIgE levels. The SSIgE has higher sensitivity and PPV, but lacks specificity. Higher sensitivity with low specificity leads to increased false positive diagnosis of allergic disease. Unlike allergenic pollens, however, insect antigen extracts from different regions seem to give comparable results, and can thus, reliably be used in the evaluation of allergy.
NASA Astrophysics Data System (ADS)
Futia, Gregory L.; Qamar, Lubna; Behbakht, Kian; Gibson, Emily A.
2016-04-01
Circulating tumor cell (CTC) identification has applications in both early detection and monitoring of solid cancers. The rarity of CTCs, expected at ~1-50 CTCs per million nucleated blood cells (WBCs), requires identifying methods based on biomarkers with high sensitivity and specificity for accurate identification. Discovery of biomarkers with ever higher sensitivity and specificity to CTCs is always desirable to potentially find more CTCs in cancer patients thus increasing their clinical utility. Here, we investigate quantitative image cytometry measurements of lipids with the biomarker panel of DNA, Cytokeratin (CK), and CD45 commonly used to identify CTCs. We engineered a device for labeling suspended cell samples with fluorescent antibodies and dyes. We used it to prepare samples for 4 channel confocal laser scanning microscopy. The total data acquired at high resolution from one sample is ~ 1.3 GB. We developed software to perform the automated segmentation of these images into regions of interest (ROIs) containing individual cells. We quantified image features of total signal, spatial second moment, spatial frequency second moment, and their product for each ROI. We performed measurements on pure WBCs, cancer cell line MCF7 and mixed samples. Multivariable regressions and feature selection were used to determine combination features that are more sensitive and specific than any individual feature separately. We also demonstrate that computation of spatial characteristics provides higher sensitivity and specificity than intensity alone. Statistical models allowed quantification of the required sensitivity and specificity for detecting small levels of CTCs in a human blood sample.
Sensitivity and specificity of two different automated external defibrillators.
Israelsson, Johan; Wangenheim, Burkard von; Årestedt, Kristofer; Semark, Birgitta; Schildmeijer, Kristina; Carlsson, Jörg
2017-11-01
The aim was to investigate the clinical performance of two different types of automated external defibrillators (AEDs). Three investigators reviewed 2938 rhythm analyses performed by AEDs in 240 consecutive patients (median age 72, q1-q3=62-83) who had suffered cardiac arrest between January 2011 and March 2015. Two different AEDs were used (AED A n=105, AED B n=135) in-hospital (n=91) and out-of-hospital (n=149). Among 194 shockable rhythms, 17 (8.8%) were not recognized by AED A, while AED B recognized 100% (n=135) of shockable episodes (sensitivity 91.2 vs 100%, p<0.01). In AED A, 8 (47.1%) of these episodes were judged to be algorithm errors while 9 (52.9%) were caused by external artifacts. Among 1039 non-shockable rhythms, AED A recommended shock in 11 (1.0%), while AED B recommended shock in 63 (4.1%) of 1523 episodes (specificity 98.9 vs 95.9, p<0.001). In AED A, 2 (18.2%) of these episodes were judged to be algorithm errors (AED B, n=40, 63.5%), while 9 (81.8%) were caused by external artifacts (AED B, n=23, 36.5%). There were significant differences in sensitivity and specificity between the two different AEDs. A higher sensitivity of AED B was associated with a lower specificity while a higher specificity of AED A was associated with a lower sensitivity. AED manufacturers should work to improve the algorithms. In addition, AED use should always be reviewed with a routine for giving feedback, and medical personnel should be aware of the specific strengths and shortcomings of the device they are using. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Zhong-Wei; Zhu, Li-Jun; Hou, Qing-Yi; Wang, Qi-Peng; Jiang, Sui; Feng, Hang
2008-12-01
To evaluate the value of positron-emission tomography (PET) for the identification of cervical nodal metastases of head and neck cancer compared with CT/MRI and clinical palpation. Forty patients of head and neck cancer underwent PET and CT/MRI examination 2 weeks before surgery. PET, CT/MRI and clinical palpation were interpreted separately to assess regional lymph node status. Histopathologic analysis was used as the gold standard for assessment of the lymph node involvement. Differences in sensitivity, specificity and accuracy among the imaging modalities and clinical palpation were analyzed. The sensitivity of PET for the identification of nodal metastases was 14.3% higher than that of CT/MRI (P = 0.648) and 14.3% higher than that of clinical palpation (P = 0.648), whereas the specificity of PET was 15.4% higher than that of CT/MRI (P = 0.188) and 7.7% higher than that of clinical palpation (P = 0.482). The accuracy of 18F-FDG PET, CT/MRI, and clinical palpation for the identification of cervical nodal metastases was 85.0%, 70.0% and 75.0% respectively. The sensitivity, specificity and accuracy of PET for the detection of cervical nodal metastases was higher than that of CT/MRI and clinical palpation. Although the results did not show a statistically significant difference, PET can still serve as a supplementary method for the identification of nodal metastases of head and neck cancer.
Ciatto, Stefano; Bonardi, Rita; Lombardi, Claudio; Zappa, Marco; Gervasi, Ginetta
2002-01-01
To evaluate the sensitivity at transrectal ultrasonography (TRUS) for prostate cancer. A consecutive series of 170 prostate cancers identified by matching local cancer registry and TRUS archives at the Centro per lo Studio e la Prevenzione Oncologica of Florence. TRUS sensitivity was determined as the ratio of TRUS positive to total prostate cancers occurring at different intervals from TRUS date. Univariate and multivariate analyses of sensitivity determinants were performed. Sensitivity at 6 months, 1, 2 and 3 years after the test was 94.1% (95% CI, 90-98), 89.8% (95% CI, 85-95), 80.4% (95% CI, 74-87) and 74.1% (95% CI, 68-81%), respectively. A higher sensitivity (statistically significant) of TRUS was observed only if digital rectal examination was suspicious, whereas no association to sensitivity was observed for age, prostate-specific antigen or prostate-specific antigen density. The study provided a reliable estimate of TRUS sensitivity, particularly reliable being checked against a cancer registry: observed sensitivity was high, at least of the same magnitude of other cancer screening tests. TRUS, which is known to allow for considerable diagnostic anticipation and is more specific than prostate-specific antigen, might still be considered for its contribution to a screening approach.
Detection of Citrus tristeza virus by using fluorescence resonance energy transfer-based biosensor
NASA Astrophysics Data System (ADS)
Shojaei, Taha Roodbar; Salleh, Mohamad Amran Mohd; Sijam, Kamaruzaman; Rahim, Raha Abdul; Mohsenifar, Afshin; Safarnejad, Reza; Tabatabaei, Meisam
2016-12-01
Due to the low titer or uneven distribution of Citrus tristeza virus (CTV) in field samples, detection of CTV by using conventional detection techniques may be difficult. Therefore, in the present work, the cadmium-telluride quantum dots (QDs) was conjugated with a specific antibody against coat protein (CP) of CTV, and the CP were immobilized on the surface of gold nanoparticles (AuNPs) to develop a specific and sensitive fluorescence resonance energy transfer (FRET)-based nanobiosensor for detecting CTV. The maximum FRET efficiency for the developed nano-biosensor was observed at 60% in AuNPs-CP/QDs-Ab ratio of 1:8.5. The designed system showed higher sensitivity and specificity over enzyme linked immunosorbent assay (ELISA) with a limit of detection of 0.13 μg mL- 1 and 93% and 94% sensitivity and specificity, respectively. As designed sensor is rapid, sensitive, specific and efficient in detecting CTV, this could be envisioned for diagnostic applications, surveillance and plant certification program.
Arbyn, Marc; Buntinx, Frank; Van Ranst, Marc; Paraskevaidis, Evangelos; Martin-Hirsch, Pierre; Dillner, Joakim
2004-02-18
The appropriate management of women with minor cytologic lesions in their cervix is unclear. We performed a meta-analysis to assess the accuracy of human papillomavirus (HPV) DNA testing as an alternative to repeat cytology in women who had equivocal results on a previous Pap smear. Data were extracted from articles published between 1992 and 2002 that contained results of virologic and cytologic testing followed by colposcopically directed biopsy in women with an index smear showing atypical cells of undetermined significance (ASCUS). Fifteen studies were identified in which HPV triage and the histologic outcome (presence or absence of a cervical intraepithelial neoplasia of grade II or worse [CIN2+]) was documented. Nine, seven, and two studies also documented the accuracy of repeat cytology when the cutoff for abnormal cytology was set at a threshold of ASCUS or worse, low-grade squamous intraepithelial lesion (LSIL) or worse, or high-grade squamous intraepithelial lesion (HSIL) or worse, respectively. Random-effects models were used for pooling of accuracy parameters in case of interstudy heterogeneity. Differences in accuracy were assessed by pooling the ratio of the sensitivity (or specificity) of HPV testing to that of repeat cytology. The sensitivity and specificity were 84.4% (95% confidence interval [CI] = 77.6% to 91.1%) and 72.9% (95% CI = 62.5% to 83.3%), respectively, for HPV testing overall and 94.8% (95% CI = 92.7% to 96.9%) and 67.3% (95% CI = 58.2% to 76.4%), respectively, for HPV testing in the eight studies that used the Hybrid Capture II assay. Sensitivity and specificity of repeat cytology at a threshold for abnormal cytology of ASCUS or worse was 81.8% (95% CI = 73.5% to 84.3%) and 57.6% (95% CI = 49.5% to 65.7%), respectively. Repeat cytology that used higher cytologic thresholds yielded substantially lower sensitivity but higher specificity than triage with the Hybrid Capture II assay. The ratio of the sensitivity of the Hybrid Capture II assay to that of repeat cytology at a threshold of ASCUS or worse pooled from the four studies that used both triage tests was 1.16 (95% CI = 1.04 to 1.29). The specificity ratio was not statistically different from unity. The published literature indicates that the Hybrid Capture II assay has improved accuracy (higher sensitivity, similar specificity) than the repeat Pap smear using the threshold of ASCUS for an outcome of CIN2+ among women with equivocal cytologic results. The sensitivity of triage at higher cytologic cutoffs is poor.
Martínez-Sánchez, Jose M; Fu, Marcela; Ariza, Carles; López, María J; Saltó, Esteve; Pascual, José A; Schiaffino, Anna; Borràs, Josep M; Peris, Mercè; Agudo, Antonio; Nebot, Manel; Fernández, Esteve
2009-01-01
To assess the optimal cut-point for salivary cotinine concentration to identify smoking status in the adult population of Barcelona. We performed a cross-sectional study of a representative sample (n=1,117) of the adult population (>16 years) in Barcelona (2004-2005). This study gathered information on active and passive smoking by means of a questionnaire and a saliva sample for cotinine determination. We analyzed sensitivity and specificity according to sex, age, smoking status (daily and occasional), and exposure to second-hand smoke at home. ROC curves and the area under the curve were calculated. The prevalence of smokers (daily and occasional) was 27.8% (95% CI: 25.2-30.4%). The optimal cut-point to discriminate smoking status was 9.2 ng/ml (sensitivity=88.7% and specificity=89.0%). The area under the ROC curve was 0.952. The optimal cut-point was 12.2 ng/ml in men and 7.6 ng/ml in women. The optimal cut-point was higher at ages with a greater prevalence of smoking. Daily smokers had a higher cut-point than occasional smokers. The optimal cut-point to discriminate smoking status in the adult population is 9.2 ng/ml, with sensitivities and specificities around 90%. The cut-point was higher in men and in younger people. The cut-point increases with higher prevalence of daily smokers.
CNG site-specific and methyl-sensitive endonuclease WEN1 from wheat seedlings.
Fedoreyeva, L I; Vanyushin, B F
2011-06-01
Endonuclease WEN1 with apparent molecular mass about 27 kDa isolated from cytoplasmic vesicular fraction of aging coleoptiles of wheat seedlings has expressed site specificity action. This is a first detection and isolation of a site-specific endonuclease from higher eukaryotes, in general, and higher plants, in particular. The enzyme hydrolyzes deoxyribooligonucleotides of different composition on CNG (N is G, A, C, or T) sites by splitting the phosphodiester bond between C and N nucleotide residues in CNG sequence independent from neighbor nucleotide context except for CCCG. WEN1 prefers to hydrolyze methylated λ phage DNA and double-stranded deoxyribooligonucleotides containing 5-methylcytosine sites (m(5)CAG, m(5)CTG) compared with unmethylated substrates. The enzyme is also able to hydrolyze single-stranded substrates, but in this case it splits unmethylated substrates predominantly. Detection in wheat seedlings of WEN1 endonuclease that is site specific, sensitive to the substrate methylation status, and modulated with S-adenosyl-L-methionine indicates that in higher plants restriction--modification systems or some of their elements, at least, may exist.
Keren, Tomer; Yarmus, Merav; Halevy, Galia; Shapira, Roni
2004-01-01
Immunoassays with specific antibodies offer higher sensitivity than do bioassays with indicator strains in the detection and quantification of several bacteriocins. Here we present the purification of lacticin RM and the production of specific polyclonal antibodies to a synthetic peptide resembling an internal fragment of the mature bacteriocin. The specificity and sensitivity of the generated polyclonal antibodies were evaluated in various immunoassays. The detection limits of lacticin RM were found to be 1.9, 0.16, and 0.18 μg ml−1 for Western blot, immuno-dot blot, and noncompetitive indirect enzyme-linked immunosorbent assays, respectively. Immunoassay sensitivities were 12.5-fold higher than that of the agar diffusion test (ADT). The production of lacticin RM showed temperature dependency, with 3, 4.2, 12.7, 28.9, 37.8, and 12 μg ml−1 at 37, 30, 20, 15, 10, and 4°C, respectively. Temperature-stability analysis demonstrated that lacticin RM is sensitive to mild temperature, but the loss of activity does not seem to result from protein degradation. Tween 80 increased the concentration of lacticin RM eightfold and probably affected the results of the ADT either by enhancing the activity of lacticin RM or by increasing the sensitivity of the indicator strain. The use of antibodies for the specific detection and quantification of lacticin RM can expand our knowledge of its production and stability, with important implications for further investigation and future application. PMID:15066801
Skeletal Muscle Triglycerides, Diacylglycerols, and Ceramides in Insulin Resistance
Amati, Francesca; Dubé, John J.; Alvarez-Carnero, Elvis; Edreira, Martin M.; Chomentowski, Peter; Coen, Paul M.; Switzer, Galen E.; Bickel, Perry E.; Stefanovic-Racic, Maja; Toledo, Frederico G.S.; Goodpaster, Bret H.
2011-01-01
OBJECTIVE Chronic exercise and obesity both increase intramyocellular triglycerides (IMTGs) despite having opposing effects on insulin sensitivity. We hypothesized that chronically exercise-trained muscle would be characterized by lower skeletal muscle diacylglycerols (DAGs) and ceramides despite higher IMTGs and would account for its higher insulin sensitivity. We also hypothesized that the expression of key skeletal muscle proteins involved in lipid droplet hydrolysis, DAG formation, and fatty-acid partitioning and oxidation would be associated with the lipotoxic phenotype. RESEARCH DESIGN AND METHODS A total of 14 normal-weight, endurance-trained athletes (NWA group) and 7 normal-weight sedentary (NWS group) and 21 obese sedentary (OBS group) volunteers were studied. Insulin sensitivity was assessed by glucose clamps. IMTGs, DAGs, ceramides, and protein expression were measured in muscle biopsies. RESULTS DAG content in the NWA group was approximately twofold higher than in the OBS group and ~50% higher than in the NWS group, corresponding to higher insulin sensitivity. While certain DAG moieties clearly were associated with better insulin sensitivity, other species were not. Ceramide content was higher in insulin-resistant obese muscle. The expression of OXPAT/perilipin-5, adipose triglyceride lipase, and stearoyl-CoA desaturase protein was higher in the NWA group, corresponding to a higher mitochondrial content, proportion of type 1 myocytes, IMTGs, DAGs, and insulin sensitivity. CONCLUSIONS Total myocellular DAGs were markedly higher in highly trained athletes, corresponding with higher insulin sensitivity, and suggest a more complex role for DAGs in insulin action. Our data also provide additional evidence in humans linking ceramides to insulin resistance. Finally, this study provides novel evidence supporting a role for specific skeletal muscle proteins involved in intramyocellular lipids, mitochondrial oxidative capacity, and insulin resistance. PMID:21873552
Sufficiently elucidating uncertainty and sensitivity structures in environmental models can be a difficult task, even for low-order, single-media constructs driven by a unique set of site-specific data. The ensuing challenge of examining ever more complex, integrated, higher-ord...
Automatic detection of ECG cable interchange by analyzing both morphology and interlead relations.
Han, Chengzong; Gregg, Richard E; Feild, Dirk Q; Babaeizadeh, Saeed
2014-01-01
ECG cable interchange can generate erroneous diagnoses. For algorithms detecting ECG cable interchange, high specificity is required to maintain a low total false positive rate because the prevalence of interchange is low. In this study, we propose and evaluate an improved algorithm for automatic detection and classification of ECG cable interchange. The algorithm was developed by using both ECG morphology information and redundancy information. ECG morphology features included QRS-T and P-wave amplitude, frontal axis and clockwise vector loop rotation. The redundancy features were derived based on the EASI™ lead system transformation. The classification was implemented using linear support vector machine. The development database came from multiple sources including both normal subjects and cardiac patients. An independent database was used to test the algorithm performance. Common cable interchanges were simulated by swapping either limb cables or precordial cables. For the whole validation database, the overall sensitivity and specificity for detecting precordial cable interchange were 56.5% and 99.9%, and the sensitivity and specificity for detecting limb cable interchange (excluding left arm-left leg interchange) were 93.8% and 99.9%. Defining precordial cable interchange or limb cable interchange as a single positive event, the total false positive rate was 0.7%. When the algorithm was designed for higher sensitivity, the sensitivity for detecting precordial cable interchange increased to 74.6% and the total false positive rate increased to 2.7%, while the sensitivity for detecting limb cable interchange was maintained at 93.8%. The low total false positive rate was maintained at 0.6% for the more abnormal subset of the validation database including only hypertrophy and infarction patients. The proposed algorithm can detect and classify ECG cable interchanges with high specificity and low total false positive rate, at the cost of decreased sensitivity for certain precordial cable interchanges. The algorithm could also be configured for higher sensitivity for different applications where a lower specificity can be tolerated. Copyright © 2014 Elsevier Inc. All rights reserved.
Connolly, Keith P; Schwartzberg, Randy S; Reuss, Bryan; Crumbie, David; Homan, Brad M
2013-02-20
Magnetic resonance imaging (MRI) has been suggested to be of high accuracy at academic institutions in the identification of superior labral tears; however, many Type-II superior labral anterior-posterior (SLAP) lesions encountered during arthroscopy have not been previously diagnosed with noncontrast images. This study evaluated the accuracy of diagnosing Type-II SLAP lesions in a community setting with use of noncontrast MRI and analyzed the effect that radiologist training and the scanner type or magnet strength had on sensitivity and specificity. One hundred and forty-four patients requiring repair of an arthroscopically confirmed Type-II SLAP lesion who had a noncontrast MRI examination performed within twelve months before the procedure were included in the sensitivity analysis. An additional 100 patients with arthroscopically confirmed, normal superior labral anatomy were identified for specificity analysis. The transcribed interpretations of the images by the radiologists were used to document the diagnosis of a SLAP lesion and were compared with the operative report. The magnet strength, type of MRI system (open or closed), and whether the radiologist had completed a musculoskeletal fellowship were also recorded. Noncontrast MRI identified SLAP lesions in fifty-four of 144 shoulders, yielding an overall sensitivity of 38% (95% confidence interval [CI] = 30%, 46%). Specificity was 94% (95% CI = 87%, 98%), with six SLAP lesions diagnosed in 100 shoulders that did not contain the lesion. Musculoskeletal fellowship-trained radiologists performed with higher sensitivity than those who had not completed the fellowship (46% versus 19%; p = 0.009). Our results demonstrate a low sensitivity and high specificity in the diagnosis of Type-II SLAP lesions with noncontrast MRI in this community setting. Musculoskeletal fellowship-trained radiologists had significantly higher sensitivities in accurately diagnosing the lesion than did radiologists without such training. Noncontrast MRI is not a reliable diagnostic tool for Type-II SLAP lesions in a community setting.
Evaluation of the Diagnostic Utility of the Traditional and Revised WHO Dengue Case Definitions
Gutiérrez, Gamaliel; Gresh, Lionel; Pérez, María Ángeles; Elizondo, Douglas; Avilés, William; Kuan, Guillermina; Balmaseda, Ángel; Harris, Eva
2013-01-01
Dengue, a mosquito-borne viral illness, is a major public health problem worldwide, and its incidence continues to increase. In 2009, the World Health Organization published guidelines that included a revision of the dengue case definition. Compared to the traditional definition, the revised case definition relies more on signs than on symptoms, making it more applicable to young children. We evaluated the diagnostic utility of both case definitions in two studies of pediatric dengue in Managua, Nicaragua. In a community-based cohort study, we included data from 3,407 suspected dengue cases, of which 476 were laboratory-confirmed. In the second study, we collected information from 1,160 participants recruited at the national pediatric reference hospital (723 laboratory-confirmed). In the cohort study, the traditional definition had 89.3% sensitivity and 43.1% specificity, while the revised definition yielded similar sensitivity (86.6%) and higher specificity (55.2%, p<0.001). In the hospital study, the traditional case definition yielded 96.7% sensitivity and 22.0% specificity, whereas the revised case definition had higher sensitivity (99.3%, p<0.001) but lower specificity (8.5%, p<0.001). We then evaluated the performance of two diagnostic models based on the signs/symptoms included in each definition by analyzing the effect of increasing numbers of signs/symptoms on the sensitivity and specificity of case capture. Receiver operating characteristic analysis showed a slightly better performance for the revised model in both studies. Interestingly, despite containing less symptoms that cannot be readily expressed by children aged less than 4 years, the revised definition did not perform better in this age group. Overall, our results indicate that both case definitions have similar capacity to diagnose dengue. Owing to their high sensitivity and low specificity, they should be primarily used for screening purposes. However, in a primary care setting, neither of the case definitions performed well as a screening test in younger children. PMID:23991237
Liu, Tao; Xu, Wen; Yan, Wei-Li; Ye, Ming; Bai, Yong-Rui; Huang, Gang
2007-12-01
To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma. MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard. Two reviewers independently extracted data. A software called "Meta-DiSc" was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the Q* index. Twenty-one articles fulfilled all inclusion criteria. The pooled sensitivity estimates for PET (95%) were significantly higher than CT (76%) (P<0.001) and MRI (78%) (P<0.001). The pooled specificity estimates for PET (90%) were significantly higher than CT (59%) (P<0.001) and MRI (76%) (P<0.001). The pooled DOR estimates for PET (96.51) were significantly higher than CT (7.01) (P<0.001) and MRI (8.68) (P<0.001). SROC curve for FDG-PET showed better diagnostic accuracy than CT and MRI. The Q* index for PET (0.92) was significantly higher than CT (0.72) (P<0.001) and MRI (0.76) (P<0.01). For PET, the sensitivity and diagnostic OR for using qualitative analysis were significantly higher than using both qualitative and quantitative analyses (P<0.01). For CT, the sensitivity, specificity, diagnostic OR, and the Q* index for dual-section helical and multi-section helical were all significantly higher than nonhelical and single-section helical (P<0.01). And the sensitivity for 'section thickness <5 mm' was significantly lower than ' =5 mm' (P<0.01), while the specificity was significantly higher (P<0.01). For MRI, there were no significant differences found between magnetic field strength <1.5 and > or =1.5 T (P>0.05). FDG-PET was the best modality for diagnosis of local residual or recurrent nasopharyngeal carcinoma. The type of analysis for PET imaging and the section thickness for CT would affect the diagnostic results. Dual-section helical and multi-section helical CT were better than nonhelical and single-section helical CT.
The Clinical Impact of Bet v 6 in Birch Pollen-Sensitized Patients.
Gellrich, Donata; Eder, Katharina; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz
2017-01-01
Bet v 6, a minor birch pollen allergen, is commercially available for allergen-specific IgE antibody testing. However, there is hardly any literature on the clinical impact of Bet v 6. The aim of the present study was to analyze if testing specific IgE against Bet v 6 can add valuable benefit to the standard diagnostics of birch pollen-sensitized patients, especially in patients with unknown sensitization-eliciting allergens. Birch pollen-sensitized patients with missing IgE reactivity against Bet v 1, 2, and 4 were tested for specific IgE antibodies against Bet v 6. For comparison, an equal number of randomly selected patients with birch pollen sensitization, regardless of their individual sensitization patterns, were tested for specific anti-Bet v 6. Of 57 cases with missing reactivity against the standard birch pollen allergens, 2 patients were positive for Bet v 6. In the representative sample, 3 patients showed specific IgE against Bet v 6 - resulting in a total prevalence of 5%. None of the Bet v 6-positive patients showed allergic symptoms after exposure to birch pollen or an oral allergy syndrome. An increased prevalence of asthma and a higher degree of sensitization were the only distinctive clinical features in Bet v 6-positive patients. Among birch pollen-sensitized patients, the prevalence of specific IgE against Bet v 6 is low. Further, sensitization to Bet v 6, which shows characteristics of a panallergen, remains clinically silent. Therefore, determination of anti-Bet v 6 is not considered useful in the clinical routine. © 2017 S. Karger AG, Basel.
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-12-01
To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.
Safety and clinical performance of acoustic reflex tests.
Hunter, L L; Ries, D T; Schlauch, R S; Levine, S C; Ward, W D
1999-12-01
Safety and effectiveness of acoustic reflex tests are important issues because these tests are widely applied to screen for retrocochlear pathology. Previous studies have reported moderately high sensitivity and specificity for detection of acoustic neuroma. However, there have been reports of possible iatrogenic hearing loss resulting from acoustic reflex threshold (ART) and decay (ARD) tests. This study assessed safety and clinical performance of ART tests for detection of acoustic neuroma. We report a case in which ARD testing resulted in a significant bilateral permanent threshold shift. This case was the impetus for us to investigate the clinical utility of ART and ARD tests. We analyzed sensitivity and specificity of ART, as well as asymmetry in pure-tone thresholds (PTT) for detection of acoustic neuroma in 56 tumor and 108 non-tumor ears. Sensitivity and specificity were higher for PTT asymmetry than for ART. Ipsilateral ART at 1000 Hz had poor sensitivity and specificity for detection of acoustic neuroma, and involves some potential risk to residual hearing for presentation levels higher than 115 dB SPL. Approximately half of the acoustic neuroma group had ipsilateral ARTs that would require administration of ARD tests at levels exceeding 115 dB SPL. Therefore, we conclude that PTT asymmetry is a more effective test for detection of acoustic neuroma, and involves no risk to residual hearing. Future studies of contralateral reflex threshold and ARD in combination with PTT asymmetry are recommended.
Kroghsbo, Stine; Rigby, Neil M.; Johnson, Philip E.; Adel-Patient, Karine; Bøgh, Katrine L.; Salt, Louise J.; Mills, E. N. Clare; Madsen, Charlotte B.
2014-01-01
Background IgE-binding of process-modified foods or proteins is the most common method for examination of how food processing affects allergenicity of food allergens. How processing affects sensitization capacity is generally studied by administration of purified food proteins or food extracts and not allergens present in their natural food matrix. Objectives The aim was to investigate if thermal processing increases sensitization potential of whole peanuts via the oral route. In parallel, the effect of heating on sensitization potential of the major peanut allergen Ara h 1 was assessed via the intraperitoneal route. Methods Sensitization potential of processed peanut products and Ara h 1 was examined in Brown Norway (BN) rats by oral administration of blanched or oil-roasted peanuts or peanut butter or by intraperitoneal immunization of purified native (N-), heated (H-) or heat glycated (G-)Ara h 1. Levels of specific IgG and IgE were determined by ELISA and IgE functionality was examined by rat basophilic leukemia (RBL) cell assay. Results In rats dosed orally, roasted peanuts induced significant higher levels of specific IgE to NAra h 1 and 2 than blanched peanuts or peanut butter but with the lowest level of RBL degranulation. However, extract from roasted peanuts was found to be a superior elicitor of RBL degranulation. Process-modified Ara h 1 had similar sensitizing capacity as NAra h 1 but specific IgE reacted more readily with process-modified Ara h 1 than with native. Conclusions Peanut products induce functional specific IgE when dosed orally to BN rats. Roasted peanuts do not have a higher sensitizing capacity than blanched peanuts. In spite of this, extract from roasted peanuts is a superior elicitor of RBL cell degranulation irrespectively of the peanut product used for sensitization. The results also suggest that new epitopes are formed or disclosed by heating Ara h 1 without glucose. PMID:24805813
The utility of serum tryptase in the diagnosis of food-induced anaphylaxis.
Wongkaewpothong, Patcharaporn; Pacharn, Punchama; Sripramong, Chaweewan; Boonchoo, Siribangon; Piboonpocanun, Surapon; Visitsunthorn, Nualanong; Vichyanond, Pakit; Jirapongsananuruk, Orathai
2014-07-01
This study investigates the utility of serum tryptase for the confirmation of shrimp-induced anaphylaxis. Patients with a history of shrimp allergy and positive skin prick tests (SPT) to commercial shrimp extract were recruited for shrimp challenges. Serum total tryptase was obtained at baseline and 60 min (peak) after the onset of symptoms. Thirty-nine patients were challenged. There were 12 patients with anaphylaxis, 20 with mild reactions and 7 without symptoms (control group). Characteristic features and baseline tryptase were not different among the 3 groups. The peak tryptase levels were higher than the baseline in anaphylaxis and mild reaction groups (P<0.05). The delta-tryptase (peak minus baseline) and the tryptase ratio (peak divided by baseline) in the anaphylaxis group were higher than the mild reaction and control groups (P<0.01). The optimum cut-off for peak tryptase to confirm anaphylaxis was 2.99 µg/L with 50% sensitivity, 85% specificity, 3.33 positive likelihood ratio (LR) and 0.59 negative LR. The manufacturer's cut-off for peak tryptase was >11.4 µg/L with 17% sensitivity, 100% specificity, infinity positive LR and 0.83 negative LR. The best cut-off for delta-tryptase was ≥0.8 µg/L with 83% sensitivity, 93% specificity, 11.86 positive LR and 0.18 negative LR. The best cut-off for tryptase ratio was ≥1.5 with 92% sensitivity, 96% specificity, 23 positive LR and 0.08 negative LR. The peak tryptase level should be compared with the baseline value to confirm anaphylaxis. The tryptase ratio provide the best sensitivity, specificity, positive and negative LR than a single peak serum tryptase for the confirmation of shrimp-induced anaphylaxis.
van Dijken, Bart R J; van Laar, Peter Jan; Holtman, Gea A; van der Hoorn, Anouk
2017-10-01
Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. • Treatment response assessment in high-grade gliomas with anatomical MRI is unreliable • Novel advanced MRI techniques have been studied, but diagnostic accuracy is unknown • Meta-analysis demonstrates that advanced MRI showed higher diagnostic accuracy than anatomical MRI • Highest diagnostic accuracy for spectroscopy and perfusion MRI • Supports the incorporation of advanced MRI in high-grade glioma treatment response assessment.
Liles, Elizabeth G; Perrin, Nancy; Rosales, Ana G; Smith, David H; Feldstein, Adrianne C; Mosen, David M; Levin, Theodore R
2018-05-02
The fecal immunochemical test (FIT) is easier to use and more sensitive than the guaiac fecal occult blood test, but it is unclear how to optimize FIT performance. We compared the sensitivity and specificity for detecting advanced colorectal neoplasia between single-sample (1-FIT) and two-sample (2-FIT) FIT protocols at a range of hemoglobin concentration cutoffs for a positive test. We recruited 2,761 average-risk men and women ages 49-75 referred for colonoscopy within a large nonprofit, group-model health maintenance organization (HMO), and asked them to complete two separate single-sample FITs. We generated receiver-operating characteristic (ROC) curves to compare sensitivity and specificity estimates for 1-FIT and 2-FIT protocols among those who completed both FIT kits and colonoscopy. We similarly compared sensitivity and specificity between hemoglobin concentration cutoffs for a single-sample FIT. Differences in sensitivity and specificity between the 1-FIT and 2-FIT protocols were not statistically significant at any of the pre-specified hemoglobin concentration cutoffs (10, 15, 20, 25, and 30 μg/g). There was a significant difference in test performance of the one-sample FIT between 50 ng/ml (10 μg/g) and each of the higher pre-specified cutoffs. Disease prevalence was low. A two-sample FIT is not superior to a one-sample FIT in detection of advanced adenomas; the one-sample FIT at a hemoglobin concentration cutoff of 50 ng/ml (10 μg/g) is significantly more sensitive for advanced adenomas than at higher cutoffs. These findings apply to a population of younger, average-risk patients in a U.S. integrated care system with high rates of prior screening.
Posturography and locomotor tests of dynamic balance after long-duration spaceflight.
Cohen, Helen S; Kimball, Kay T; Mulavara, Ajitkumar P; Bloomberg, Jacob J; Paloski, William H
2012-01-01
The currently approved objective clinical measure of standing balance in astronauts after space flight is the Sensory Organization Test battery of computerized dynamic posturography. No tests of walking balance are currently approved for standard clinical testing of astronauts. This study determined the sensitivity and specificity of standing and walking balance tests for astronauts before and after long-duration space flight. Astronauts were tested on an obstacle avoidance test known as the Functional Mobility Test (FMT) and on the Sensory Organization Test using sway-referenced support surface motion with eyes closed (SOT 5) before and six months after (n=15) space flight on the International Space Station. They were tested two to seven days after landing. Scores on SOT tests decreased and scores on FMT increased significantly from pre- to post-flight. In other words, post-flight scores were worse than pre-flight scores. SOT and FMT scores were not significantly related. ROC analyses indicated supra-clinical cut-points for SOT 5 and for FMT. The standard clinical cut-point for SOT 5 had low sensitivity to post-flight astronauts. Higher cut-points increased sensitivity to post-flight astronauts but decreased specificity to pre-flight astronauts. Using an FMT cut-point that was moderately highly sensitive and highly specific plus SOT 5 at the standard clinical cut-point was no more sensitive than SOT 5, alone. FMT plus SOT 5 at higher cut-points was more specific and more sensitive. The total correctly classified was highest for FMT, alone, and for FMT plus SOT 5 at the highest cut-point. These findings indicate that standard clinical comparisons are not useful for identifying problems. Testing both standing and walking balance will be more likely to identify balance deficits.
Sousa, Susana; Cardoso, Luís; Reed, Steven G.; Reis, Alexandre B.; Martins-Filho, Olindo A.; Silvestre, Ricardo; Cordeiro da Silva, Anabela
2013-01-01
Background An accurate diagnosis is essential for the control of infectious diseases. In the search for effective and efficient tests, biosensors have increasingly been exploited for the development of new and highly sensitive diagnostic methods. Here, we describe a new fluorescent based immunosensor comprising magnetic polymer microspheres coated with recombinant antigens to improve the detection of specific antibodies generated during an infectious disease. As a challenging model, we used canine leishmaniasis due to the unsatisfactory sensitivity associated with the detection of infection in asymptomatic animals where the levels of pathogen-specific antibodies are scarce. Methodology Ni-NTA magnetic microspheres with 1,7 µm and 8,07 µm were coated with the Leishmania recombinant proteins LicTXNPx and rK39, respectively. A mixture of equal proportions of both recombinant protein-coated microspheres was used to recognize and specifically bind anti-rK39 and anti-LicTNXPx antibodies present in serum samples of infected dogs. The microspheres were recovered by magnetic separation and the percentage of fluorescent positive microspheres was quantified by flow cytometry. Principal Findings A clinical evaluation carried out with 129 dog serum samples using the antigen combination demonstrated a sensitivity of 98,8% with a specificity of 94,4%. rK39 antigen alone demonstrated a higher sensitivity for symptomatic dogs (96,9%), while LicTXNPx antigen showed a higher sensitivity for asymptomatic (94,4%). Conclusions Overall, our results demonstrated the potential of a magnetic microsphere associated flow cytometry methodology as a viable tool for highly sensitive laboratorial serodiagnosis of both clinical and subclinical forms of canine leishmaniasis. PMID:23991232
Sensitizers in EUV chemically amplified resist: mechanism of sensitivity improvement
NASA Astrophysics Data System (ADS)
Vesters, Yannick; Jiang, Jing; Yamamoto, Hiroki; De Simone, Danilo; Kozawa, Takahiro; De Gendt, Stefan; Vandenberghe, Geert
2018-03-01
EUV lithography utilizes photons with 91.6 eV energy to ionize resists, generate secondary electrons, and enable electron driven reactions that produce acid in chemically amplified photoresist. Efficiently using the available photons is of key importance. Unlike DUV lithography, where photons are selectively utilized by photoactive compounds, photons at 13.5nm wavelength ionize almost all materials. Nevertheless, specific elements have a significantly higher atomic photon-absorption cross section at 91.6 eV. To increase photon absorption, sensitizer molecules, containing highly absorbing elements, can be added to photoresist formulations. These sensitizers have gained growing attention in recent years, showing significant sensitivity improvement. But there are few experimental evidences that the sensitivity improvement is due to the higher absorption only, as adding metals salts into the resist formulation can induce other mechanisms, like modification of the dissolution rate, potentially affecting patterning performance. In this work, we used different sensitizers in chemically amplified resist. We measured experimentally the absorption of EUV light, the acid yield, the dissolution rate and the patterning performance of the resists. Surprisingly, the absorption of EUV resist was decreased with addition of metal salt sensitizers. Nevertheless, the resist with sensitizer showed a higher acid yield. Sensitizer helps achieving higher PAG conversion to acid, notably due to an increase of the secondary electron generation. Patterning data confirm a significant sensitivity improvement, but at the cost of roughness degradation at high sensitizer loading. This can be explained by the chemical distribution of the sensitizer in the resist combined with a modification of the dissolution contrast, as observed by Dissolution Rate Monitor.
Nishimura, Katsuji; Yokoyama, Kanako; Yamauchi, Noriko; Koizumi, Masako; Harasawa, Nozomi; Yasuda, Taeko; Mimura, Chizuru; Igita, Hazuki; Suzuki, Eriko; Uchiide, Yoko; Seino, Yusuke; Nomura, Minoru; Yamazaki, Kenji; Ishigooka, Jun
2016-01-01
To compare the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium. These tools have not been tested in a specialized cardio-surgical ICU. Sensitivities and specificities of each tool were assessed in a cardio-surgical ICU in Japan by two trained nurses independently. Results were compared with delirium diagnosed by psychiatrists using the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision. There were 110 daily, paired assessments in 31 patients. The CAM-ICU showed 38% sensitivity and 100% specificity for both nurses. All 20 false-negative cases resulted from high scores in the auditory attention screening in CAM-ICU. The ICDSC showed 97% and 94% sensitivity, and 97% and 91% specificity for the two nurses (cutoff ≥4). In a Japanese cardio-surgical ICU, the ICDSC had a higher sensitivity than the CAM-ICU. Copyright © 2016 Elsevier Inc. All rights reserved.
Shrestha, Swastina; Dave, Amish J; Losina, Elena; Katz, Jeffrey N
2016-07-07
Administrative health care data are frequently used to study disease burden and treatment outcomes in many conditions including osteoarthritis (OA). OA is a chronic condition with significant disease burden affecting over 27 million adults in the US. There are few studies examining the performance of administrative data algorithms to diagnose OA. The purpose of this study is to perform a systematic review of administrative data algorithms for OA diagnosis; and, to evaluate the diagnostic characteristics of algorithms based on restrictiveness and reference standards. Two reviewers independently screened English-language articles published in Medline, Embase, PubMed, and Cochrane databases that used administrative data to identify OA cases. Each algorithm was classified as restrictive or less restrictive based on number and type of administrative codes required to satisfy the case definition. We recorded sensitivity and specificity of algorithms and calculated positive likelihood ratio (LR+) and positive predictive value (PPV) based on assumed OA prevalence of 0.1, 0.25, and 0.50. The search identified 7 studies that used 13 algorithms. Of these 13 algorithms, 5 were classified as restrictive and 8 as less restrictive. Restrictive algorithms had lower median sensitivity and higher median specificity compared to less restrictive algorithms when reference standards were self-report and American college of Rheumatology (ACR) criteria. The algorithms compared to reference standard of physician diagnosis had higher sensitivity and specificity than those compared to self-reported diagnosis or ACR criteria. Restrictive algorithms are more specific for OA diagnosis and can be used to identify cases when false positives have higher costs e.g. interventional studies. Less restrictive algorithms are more sensitive and suited for studies that attempt to identify all cases e.g. screening programs.
Kim, DaeHee; Rhodes, Jeffrey A; Hashim, Jeffrey A; Rickabaugh, Lawrence; Brams, David M; Pinkus, Edward; Dou, Yamin
2018-06-07
Highly specific preoperative localizing test is required to select patients for minimally invasive parathyroidectomy (MIP) in lieu of traditional four-gland exploration. We hypothesized that Tc-99m sestamibi scan interpretation incorporating numerical measurements on the degree of asymmetrical activity from bilateral thyroid beds can be useful in localizing single adenoma for MIP. We devised a quantitative interpretation method for Tc-99m sestamibi scan based on the numerically graded asymmetrical activity on early phase. The numerical ratio value of each scan was obtained by dividing the number of counts from symmetrically drawn regions of interest (ROI) over bilateral thyroid beds. The final pathology and clinical outcome of 109 patients were used to perform receiver operating curve (ROC) analysis. Receiver operating curve analysis revealed the area under the curve (AUC) was calculated to be 0.71 (P = 0.0032), validating this method as a diagnostic tool. The optimal cut-off point for the ratio value with maximal combined sensitivity and specificity was found with corresponding sensitivity of 67.9% (56.5-77.2%, 95% CI) and specificity of 75.0% (52.8-91.8%, 95% CI). An additional higher cut-off with higher specificity with minimal possible sacrifice on sensitivity was also selected, yielding sensitivity of 28.6% (18.8-38.6%, 95% CI) and specificity of 90.0% (69.6-98.8%, 95% CI). Our results demonstrated that the more asymmetrical activity on the initial phase, the more successful it is to localize a single parathyroid adenoma on sestamibi scans. Using early-phase Tc-99m sestamibi scan only, we were able to select patients for minimally invasive parathyroidectomy with 90% specificity. © 2018 The Royal Australian and New Zealand College of Radiologists.
Fafin-Lefevre, Mélanie; Morlais, Fabrice; Guittet, Lydia; Clin, Bénédicte; Launoy, Guy; Galateau-Sallé, Françoise; Plancoulaine, Benoît; Herlin, Paulette; Letourneux, Marc
2011-08-01
To identify which morphologic or densitometric parameters are modified in cell nuclei from bronchopulmonary cancer based on 18 parameters involving shape, intensity, chromatin, texture, and DNA content and develop a bronchopulmonary cancer screening method relying on analysis of sputum sample cell nuclei. A total of 25 sputum samples from controls and 22 bronchial aspiration samples from patients presenting with bronchopulmonary cancer who were professionally exposed to cancer were used. After Feulgen staining, 18 morphologic and DNA content parameters were measured on cell nuclei, via image cytom- etry. A method was developed for analyzing distribution quantiles, compared with simply interpreting mean values, to characterize morphologic modifications in cell nuclei. Distribution analysis of parameters enabled us to distinguish 13 of 18 parameters that demonstrated significant differences between controls and cancer cases. These parameters, used alone, enabled us to distinguish two population types, with both sensitivity and specificity > 70%. Three parameters offered 100% sensitivity and specificity. When mean values offered high sensitivity and specificity, comparable or higher sensitivity and specificity values were observed for at least one of the corresponding quantiles. Analysis of modification in morphologic parameters via distribution analysis proved promising for screening bronchopulmonary cancer from sputum.
Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut
2006-01-01
Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.
de Barros, André Luís Branco; Mota, Luciene das Graças; Soares, Daniel Crístian Ferreira; de Souza, Cristina Maria; Cassali, Geovanni Dantas; Oliveira, Mônica Cristina; Cardoso, Valbert Nascimento
2013-09-01
Bombesin (BBN) is a tetradecapeptide that binds specifically to gastrin-releasing peptide receptors in humans. Several forms of cancer, including lung, prostate, breast, and colon over-express receptors for bombesin-like peptides. Therefore, radiolabeled bombesin analogs might be useful for tumor identification. Nevertheless, it is well known that higher tumor uptake can yield images in higher quality. Hence, drug delivery systems, such as liposomes, can be used to achieve a higher concentration of radiotracer in tumor site, and also improve the radiotracer stability, since peptides can suffer easily degradation in vivo by natural plasma and tissue peptides. In this paper, we prepared long-circulating, pH-sensitive liposomes and long-circulation, non-pH sensitive liposomes. Both formulations were able to encapsulate the radiolabeled bombesin derivative (99mTc-BBN(7_14)), and also showing high in vitro stability. Biodistribution studies were performed in Ehrlich tumor bearing-mice to compare the ability of pH-sensitive and non-pH sensitive liposomes to deliver 99mTc-BBN(7_14) to tumor site. Results showed higher tumor uptake (2-fold) when pH-sensitive liposomes were used, suggesting that these vesicles can facilitate the access to the tumor by releasing the diagnostic agent into the ideal area. As a result, tumor-to-muscle ratio achieved with pH-sensitive liposomes was higher than that obtained with non-pH-sensitive formulation. In addition, scintigraphic images for pH-sensitive liposomes showed evident tumor uptake, corroborating with biodistribution data. Therefore, the results presented in this paper suggest that pH-sensitive liposomes are able to deliver more efficiently the radiolabeled bombesin analog. This finding poses a new possibility to improve images quality, since the tumor-to-muscle ratio was strongly enhanced.
Sabouri, Sarah; Gerber, Markus; Lemola, Sakari; Becker, Stephen P; Shamsi, Mahin; Shakouri, Zeinab; Sadeghi Bahmani, Dena; Kalak, Nadeem; Holsboer-Trachsler, Edith; Brand, Serge
2016-07-01
The Dark Triad (DT) describes a set of three closely related personality traits, Machiavellianism, narcissism, and psychopathy. The aim of this study was to examine the associations between DT traits, sleep disturbances, anxiety sensitivity and intolerance of uncertainty. A total of 341 adults (M=29years) completed a series of questionnaires related to the DT traits, sleep disturbances, anxiety sensitivity, and intolerance of uncertainty. A higher DT total score was associated with increased sleep disturbances, and higher scores for anxiety sensitivity and intolerance of uncertainty. In regression analyses Machiavellianism and psychopathy were predictors of sleep disturbances, anxiety sensitivity, and intolerance of uncertainty. Results indicate that specific DT traits, namely Machiavellianism and psychopathy, are associated with sleep disturbances, anxiety sensitivity and intolerance of uncertainty in young adults. Copyright © 2016 Elsevier Inc. All rights reserved.
Zhang, Hai-Chun; Hu, Rong-Fei; Zhu, Ting; Tong, Ling; Zhang, Qiu-Qin
2016-06-14
To evaluate the assessment of primary biliary cirrhosis degree by acoustic radiation force impulse imaging (ARFI) and hepatic fibrosis indicators. One hundred and twenty patients who developed liver cirrhosis secondary to primary biliary cirrhosis were selected as the observation group, with the degree of patient liver cirrhosis graded by Child-Pugh (CP) score. Sixty healthy individuals were selected as the control group. The four indicators of hepatic fibrosis were detected in all research objects, including hyaluronic acid (HA), laminin (LN), type III collagen (PC III), and type IV collagen (IV-C). The liver parenchyma hardness value (LS) was then measured by ARFI technique. LS and the four indicators of liver fibrosis (HA, LN, PC III, and IV-C) were observed in different grade CP scores. The diagnostic value of LS and the four indicators of liver fibrosis in determining liver cirrhosis degree with PBC, whether used alone or in combination, were analyzed by receiver operating characteristic (ROC) curve. LS and the four indicators of liver fibrosis within the three classes (A, B, and C) of CP scores in the observation group were higher than in the control group, with C class > B class > A class; the differences were statistically significant (P < 0.01). Although AUC values of LS within the three classes of CP scores were higher than in the four indicators of liver fibrosis, sensitivity and specificity were unstable. The ROC curves of LS combined with the four indicators of liver fibrosis revealed that: AUC and sensitivity in all indicators combined in the A class of CP score were higher than in LS alone, albeit with slightly decreased specificity; AUC and specificity in all indicators combined in the B class of CP score were higher than in LS alone, with unchanged sensitivity; AUC values (0.967), sensitivity (97.4%), and specificity (90%) of all indicators combined in the C class of CP score were higher than in LS alone (0.936, 92.1%, 83.3%). The diagnostic value of PBC cirrhosis degree in liver cirrhosis degree assessment by ARFI combined with the four indicators of serum liver fibrosis is of satisfactory effectiveness and has important clinical application value.
Sonicated Diagnostic Immunoblot for Bartonellosis
Mallqui, Vania; Speelmon, Emily C.; Verástegui, Manuela; Maguiña-Vargas, Ciro; Pinell-Salles, Paula; Lavarello, Rosa; Delgado, Jose; Kosek, Margaret; Romero, Sofia; Arana, Yanina; Gilman, Robert H.
2000-01-01
Two simple Bartonella bacilliformis immunoblot preparation methods were developed. Antigen was prepared by two different methods: sonication of whole organisms or glycine extraction. Both methods were then tested for sensitivity and specificity. Well-defined control sera were utilized in the development of these diagnostic immunoblots, and possible cross-reactions were thoroughly examined. Sera investigated for cross-reaction with these diagnostic antigens were drawn from patients with brucellosis, chlamydiosis, Q fever, and cat scratch disease, all of whom were from regions where bartonellosis is not endemic. While both immunoblots yielded reasonable sensitivity and high specificity, we recommend the use of the sonicated immunoblot, which has a higher sensitivity when used to detect acute disease and produces fewer cross-reactions. The sonicated immunoblot reported here is 94% sensitive to chronic bartonellosis and 70% sensitive to acute bartonellosis. In a healthy group, it is 100% specific. This immunoblot preparation requires a simple sonication protocol for the harvesting of B. bacilliformis antigens and is well suited for use in regions of endemicity. PMID:10618267
Reitzel, Lorraine R; Childress, Sarah D; Obasi, Ezemenari M; Garey, Lorra; Vidrine, Damon J; McNeill, Lorna H; Zvolensky, Michael J
2017-01-01
Anxiety sensitivity is the fear of anxiety-related sensations and subjective social status is a self-perception of social standing relative to others: both constructs have been linked to psychological symptomatology. This study investigated the interactive effects of anxiety sensitivity and social status in relation to anxiety and depressive symptomatology expression among 124 black adults. Participants provided sociodemographics and completed self-report questionnaires. The interactive associations between anxiety sensitivity and social status on anxiety symptomatology and depressive symptomatology were examined with hierarchical linear regressions adjusted for sociodemographics and negative affectivity. Significant interactions between anxiety sensitivity and social status were evident only for anxiety symptoms: specifically, the association between anxiety sensitivity and anxiety symptoms was much stronger for individuals with lower (versus higher) subjective social status. Black adults with this higher anxiety sensitivity/lower social status phenotype may be at heightened risk for the expression of anxiety symptomatology, and may benefit from interventions to reduce anxiety sensitivity.
Correlations between serum trypsinogen-2 and pancreatic cancer.
Cao, Jianbiao; Xia, Changhong; Cui, Tingting; Guo, Hanbin; Li, Haoran; Ren, Yongqiang; Wang, Shuai
2015-01-01
To investigate associations be- tween serum trypsinogen-2, pancreatitis and pancreatic cancer (PC) and determine cutoff values for PC diagnosis. We recruited 88 patients from Internal Medicine/Surgical Departments of General Military Hospital of Beijing PLA between 12/2009 and 6/2010. Serum samples were collected preoperatively from 23 PC patients, 30 pancreatitis patients and 35 healthy controls. Enzyme-linked immunosorbent assay was used to detect trypsinogen-2 semiquantitatively. Serum trypsinogen-2 levels of PC and pancreatitis patients were significantly higher than those of controls (51.2 ± 80.3, 107.7 ± 98.1 vs. 1.0 ± 0.5, p = 0.03, p < 0.001) and significantly higher in pancreatitis vs. PC patients (107.7 ± 98.1 vs. 51.2 ± 80.3, p = 0.01). Higher Balthazar CT grades correlated with higher trypsinogen-2 in pancreatitis group. ROC curves for trypsinogen-2 revealed optimal cutoff value 1.8 as lower PC detection limit with 95.7% sensitivity and 91.4% specificity, and optimal cutoff value 19.9 for upper PC detection limit with 87.0% sensitivity and 97.1% specificity. Trypsinogen-2 levels correlated with pancreatic injury level. An AUC of 0.73 (95% Cl: 0.59-0.84, p = 0.002) distinguished PC from pancreatitis. Serum trypsinogen-2 is associated with PC and pancreatitis. Levels between 1.8 μg/L and 19.9 μg/L strongly suggest PC. Detection of serum trypsinogen-2 may provide simple, sensitive, specific non-invasive initial screening for early PC diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baliatsas, Christos, E-mail: c.baliatsas@nivel.nl
Epidemiological evidence on the symptomatic profile, health status and illness behavior of people with subjective sensitivity to noise is still scarce. Also, it is unknown to what extent noise sensitivity co-occurs with other environmental sensitivities such as multi-chemical sensitivity and sensitivity to electromagnetic fields (EMF). A cross-sectional study performed in the Netherlands, combining self-administered questionnaires and electronic medical records of non-specific symptoms (NSS) registered by general practitioners (GP) allowed us to explore this further. The study sample consisted of 5806 participants, drawn from 21 general practices. Among participants, 722 (12.5%) responded “absolutely agree” to the statement “I am sensitive tomore » noise”, comprising the high noise-sensitive (HNS) group. Compared to the rest of the sample, people in the HNS group reported significantly higher scores on number and duration of self-reported NSS, increased psychological distress, decreased sleep quality and general health, more negative symptom perceptions and higher prevalence of healthcare contacts, GP-registered NSS and prescriptions for antidepressants and benzodiazepines. These results remained robust after adjustment for demographic, residential and lifestyle characteristics, objectively measured nocturnal noise exposure from road-traffic and GP-registered morbidity. Co-occurrence rates with other environmental sensitivities varied between 9% and 50%. Individuals with self-declared sensitivity to noise are characterized by high prevalence of multiple NSS, poorer health status and increased illness behavior independently of noise exposure levels. Findings support the notion that different types of environmental sensitivities partly overlap. - Highlights: • People with self-reported noise sensitivity experience multiple non-specific symptoms. • They also report comparatively poorer health and increased illness behavior. • Co-occurrence with other environmental sensitivities is moderate to high. • Road-traffic noise and GP-registered morbidity did not account for these results.« less
Huang, Terry T-K; Nansel, Tonja R; Belsheim, Allen R; Morrison, John A
2008-02-01
To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoff points in relation to adult MetS. Data from the National Heart, Lung, and Blood Institute Lipid Research Clinics Princeton Prevalence Study (1973-1976) and the Princeton Follow-up Study (2000-2004) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff point and for aggregates of components. Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all 5 pediatric MetS components were considered, the presence of at least 1 abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Considering multiple metabolic variables in childhood can improve the predictive usefulness for adult MetS, compared with each component or body mass alone. MetS variables may be useful for identifying some children who are at risk for prevention interventions.
Determinants of child nutrition and mortality in north-west Uganda.
Vella, V; Tomkins, A; Borghesi, A; Migliori, G B; Adriko, B C; Crevatin, E
1992-01-01
An anthropometric survey of children aged 0-59 months in north-west Uganda in February-March 1987 indicated a high prevalence of stunting but little wasting. Use of unprotected water supplies in the dry season, prolonged breast-feeding, and age negatively affected nutrition; in contrast, parental education level improved nutrition. Mortality during the 12 months following the survey was higher among those who had low weight-for-age and weight-for-height, but children who had low height-for-age did not have higher mortality. Weight-for-age was the most sensitive predictor of mortality at specificities > 88%, while at lower specificity levels weight-for-height was the most sensitive. Children whose fathers' work was associated with the distillation of alcohol had a higher risk of mortality than other children. The lowest mortality was among children whose fathers were businessmen or who grew tobacco.
Lu, L; Chen, J H; Zhu, H J; Song, A L; Li, M; Chen, S; Pan, H; Gong, F Y; Wang, R Z; Xing, B; Yao, Y; Feng, M; Lu, Z L
2016-07-19
To compare the sensitivity and specificity between the 24 hour urine free cortisol (24 h UFC) and serum cortisol in dexamethasone suppression test (DST) in the diagnosis of Cushing syndrome (CS). Combined low dose DST (LDDST) and high dose DST (HDDST) were carried out in 67 cases of CS with surgically confirmed cases in recent 3 years(from January 2011 to November 2015). The serum cortisol and 24 h UFC were collected simultaneously for each subject and the sensitivity and specificity of serum cortisol and 24 h UFC were compared. There were Cushing disease (CD) group (n=53), ectopic adrenocorticotropic hormone (ACTH) syndrome group (n=7) and ACTH-independent Cushing syndrome group (n=7) according to the etiology of hypercorticordism.There were no significant differences among 3 groups in gender and age.The sensitivity of serum cortisol of different cut off points(50, 110, 140 nmol/L and 50% of control)after LDDST was 97.01%, 86.57%, 83.58% and 70.15% respectively.Meanwhile, the sensitivity of cutoff point of 24 h UFC <32 nmol in combined LDDST was 92.54% in the diagnosis of Cushing syndrome.There was no significant differences in two groups between serum cortisol <110 nmol/L and 24 h UFC <32 nmol.However, the sensitivity of serum cortisol <50 nmol/L was significantly higher than 24 h UFC<32 nmol (P<0.05). Furthermore, in combined HDDST, if the suppression rate was ≥50%, the sensitivity of serum cortisol and 24 h UFC in differentiating the etiology of Cushing disease was 60.38% and 90.57%, and the specificity was 91.43% and 96.00% respectively.There were significant differences between serum cortisol and 24 h UFC in both of sensitivity and specificity (both P<0.05). In addition, if the suppression rate of 24 h UFC in HDDST was adjusted to 60.85% according to receiver operating characteristic (ROC) curve, it could have the best levels of sensitivity (92.6%) with the specificity of 85.7%. If the suppression rate of serum cortisol was adjusted to 61.53% in HDDST according to ROC curve, it could have the best sensitivity (64.8%) with the specificity of 78.6% accordingly. In combined LDDST, the serum cortisol <50 nmol/L had a higher sensitivity than the 24 h UFC<32 nmol when they were used as the criteria in determining the diagnosis of CS.In HDDST, the sensitivity and specificity of suppression rate of 24 h UFC ≥50% were better than serum cortisol to differentiate the etiology of CS.
Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena
2016-01-01
Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. PMID:27488039
What is the best way to diagnose and stage malignant pleural mesothelioma?
Zahid, Imran; Sharif, Sumera; Routledge, Tom; Scarci, Marco
2011-02-01
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was which diagnostic modality [computed tomography (CT), positron emission tomography (PET), combination PET/CT and magnetic resonance imaging (MRI)] provides the best diagnostic and staging information in patients with malignant pleural mesothelioma (MPM). Overall, 61 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results are tabulated. We conclude that fluorodeoxyglucose (FDG)-PET is superior to MRI and CT but inferior to PET-CT, in terms of diagnostic specificity, sensitivity and staging of MPM. Four studies reported outcomes using FDG-PET to diagnose MPM. PET diagnosed MPM with high sensitivity (92%) and specificity (87.9%). Mean standardised uptake value (SUV) was higher in malignant than benign disease (4.91 vs. 1.41, P<0.0001). Lymph node metastases were detected with higher accuracy (80% vs. 66.7%) compared to extrathoracic disease. Three studies assessed the utility of PET-CT to diagnose MPM. Mean SUV was higher in malignant than benign disease (6.5 vs. 0.8, P<0.001). MPM was diagnosed with high sensitivity (88.2%), specificity (92.9%) and accuracy (88.9%). PET-CT had low sensitivity for stage N2 (38%) and T4 (67%) disease. CT-guided needle biopsy definitively diagnosed MPM after just one biopsy (100% vs. 9%) much more often than a 'blind' approach. CT had a lower success rate (92% vs. 100%) than thoracoscopic pleural biopsy but was equivalent to MRI in terms of detection of lymph node metastases (P=0.85) and visceral pleural tumour (P=0.64). CT had a lower specificity for stage II (77% vs. 100%, P<0.01) and stage III (75% vs. 100%, P<0.01) disease compared to PET-CT. Overall, the high specificity and sensitivity rates seen with open pleural biopsy make it a superior diagnostic modality to CT, MRI or PET for diagnosing patients with MPM.
The balance between caseins and whey proteins in cow's milk determines its allergenicity.
Lara-Villoslada, F; Olivares, M; Xaus, J
2005-05-01
Cow's milk allergy is quite common in the first years of human life. Protein composition plays an important role in this pathology, particularly the casein/whey protein ratio. It is known that milks from different species have different sensitization capacities although their protein sources are quite similar. Thus, the objective of this work was to compare the allergenicity of native cow's milk and milk with a modified ratio of casein and whey proteins in a murine model of atopy. Twenty-four Balb/c mice were orally sensitized to native cow's milk or modified cow's milk with a casein/whey protein ratio of 40:60. During the sensitization period, the number of mice suffering from diarrhea was significantly higher in the native cow's milk-sensitized group than in the modified milk-sensitized group. Once mice were killed, plasma histamine levels were shown to be significantly higher in native cow's milk-sensitized mice. In addition, cow's milk proteins induced a higher lymphocyte sensitization in the native milk-sensitized mice, with a significant increase in the specific proliferation ratio of these cells. These results suggest that the balance between caseins and whey proteins plays an important role in the sensitization capacity of cow's milk, and its modification might be a way to reduce the allergenicity of cow's milk.
Bijur, Polly E; Shah, Purvi D; Esses, David
2016-12-01
The objective was to compare agreement between three non-invasive measures of temperature and rectal temperatures and to estimate the sensitivity and specificity of these measures to detect a rectal temperature of 38°C or higher. We conducted a study of the diagnostic accuracy of oral, tympanic membrane (TM) and temporal artery (TA) thermometry to measure fever in an urban emergency department (ED). Data were collected from adult patients who received rectal temperature measurement. Bland-Altman analysis was performed; sensitivity, specificity and 95% CIs were calculated. 987 patients were enrolled. 36% of the TM and TA readings differed by 0.5°C or more from rectal temperatures, 50% of oral temperatures. TM measures were most precise-the SD of the difference from rectal was 0.4°C TM, and 0.6°C for oral and TA (p<0.001). The sensitivities of a 38°C cutpoint on oral, TM and TA measures to detect a rectal temperature of 38°C or higher were: 37.0%, 68.3% and 71.1%, respectively (oral vs TM and TA p<0.001). The corresponding specificities were 99.4%, 98.2% and 92.3% (oral, TM and TA) with oral specificity significantly higher than the other two methods (p<0.01). TM and TA cutpoints of 37.5°C provided greater than 90% sensitivity to detect fever with specificity of 90% and 72%, respectively. None of the non-invasive methods met benchmarks for diagnostic accuracy using the criterion of 38°C to detect rectal temperature of 38°C. A TM cutpoint of 37.5°C provides maximum diagnostic accuracy of the three non-invasive measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim
2014-01-01
There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049
Evaluation of procalcitonin for diagnosis of neonatal sepsis of vertical transmission
López Sastre, José B; Solís, David Pérez; Serradilla, Vicente Roqués; Colomer, Belén Fernández; Cotallo, Gil D Coto
2007-01-01
Background The results of recent studies suggest the usefulness of PCT for early diagnosis of neonatal sepsis, with varying results. The aim of this prospective multicenter study was to determine the behavior of serum PCT concentrations in both uninfected and infected neonates, and to assess the value of this marker for diagnosis of neonatal sepsis of vertical transmission. Methods PCT was measured in 827 blood samples collected prospectively from 317 neonates admitted to 13 acute-care teaching hospitals in Spain over one year. Serum PCT concentrations were determined by a specific immunoluminometric assay. The diagnostic efficacy of PCT at birth and within 12–24 h and 36–48 h of life was evaluated calculating the sensitivity, specificity, and likelihood ratio of positive and negative results. Results 169 asymptomatic newborns and 148 symptomatic newborns (confirmed vertical sepsis: 31, vertical clinical sepsis: 38, non-infectious diseases: 79) were studied. In asymptomatic neonates, PCT values at 12–24 h were significantly higher than at birth and at 36–48 h of life. Resuscitation at birth and chorioamnionitis were independently associated to PCT values. Neonates with confirmed vertical sepsis showed significantly higher PCT values than those with clinical sepsis. PCT thresholds for the diagnosis of sepsis were 0.55 ng/mL at birth (sensitivity 75.4%, specificity 72.3%); 4.7 ng/mL within 12–24 h of life (sensitivity 73.8%, specificity 80.8%); and 1.7 ng/mL within 36–48 h of life (sensitivity 77.6%, specificity 79.2%). Conclusion Serum PCT was moderately useful for the detection of sepsis of vertical transmission, and its reliability as a maker of bacterial infection requires specific cutoff values for each evaluation point over the first 48 h of life. PMID:17324267
Raheja, Amol; Sinha, Sumit; Samson, Neha; Bhoi, Sanjeev; Subramanian, Arulselvi; Sharma, Pushpa; Sharma, Bhawani Shankar
2016-09-01
OBJECTIVE There has been increased interest in the potential importance of biochemical parameters as predictors of outcome in severe traumatic brain injury (sTBI). METHODS Of 107 patients with sTBI (age 18-65 years with a Glasgow Coma Scale score of 4-8 presenting within 8 hours after injury) who were randomized for a placebo-controlled Phase II trial of progesterone with or without hypothermia, the authors serially analyzed serum biomarkers (S100-B, glial fibrillary acidic protein [GFAP], neuron-specific enolase [NSE], tumor necrosis factor-α, interleukin-6 [IL-6], estrogen [Eg], and progesterone [Pg]). This analysis was performed using the sandwich enzyme-linked immunosorbent assay technique at admission and 7 days later for 86 patients, irrespective of assigned group. The long-term predictive values of serum biomarkers for dichotomized Glasgow Outcome Scale (GOS) score, functional independence measure, and survival status at 6 and 12 months were analyzed using an adjusted binary logistic regression model and receiver operating characteristic curve. RESULTS A favorable GOS score (4-5) at 1 year was predicted by higher admission IL-6 (above 108.36 pg/ml; area under the curve [AUC] 0.69, sensitivity 52%, and specificity 78.6%) and Day 7 Pg levels (above 3.15 ng/ml; AUC 0.79, sensitivity 70%, and specificity 92.9%). An unfavorable GOS score (1-3) at 1 year was predicted by higher Day 7 GFAP levels (above 9.50 ng/ml; AUC 0.82, sensitivity 78.6%, and specificity 82.4%). Survivors at 1 year had significantly higher Day 7 Pg levels (above 3.15 ng/ml; AUC 0.78, sensitivity 66.7%, and specificity 90.9%). Nonsurvivors at 1 year had significantly higher Day 7 GFAP serum levels (above 11.14 ng/ml; AUC 0.81, sensitivity 81.8%, and specificity 88.9%) and Day 7 IL-6 serum levels (above 71.26 pg/ml; AUC 0.87, sensitivity 81.8%, and specificity 87%). In multivariate logistic regression analysis, independent predictors of outcome at 1 year were serum levels of Day 7 Pg (favorable GOS-OR 3.24, CI 1.5-7, p = 0.003; and favorable survival-OR 2, CI 1.2-3.5, p = 0.01); admission IL-6 (favorable GOS-OR 1.04, CI 1.00-1.08, p = 0.04); and Day 7 GFAP (unfavorable GOS-OR 0.79, CI 0.65-0.95, p = 0.01; and unfavorable survival-OR 0.80, CI 0.66-0.96, p = 0.01). CONCLUSIONS Serial Pg, GFAP, and IL-6 monitoring could aid in prognosticating outcomes in patients with acute sTBI. A cause and effect relationship or a mere association of these biomarkers to outcome needs to be further studied for better understanding of the pathophysiology of sTBI and for choosing potential therapeutic targets. Clinical trial registration no.: CTRI/2009/091/000893 ( http://www.ctri.nic.in ).
Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick M M; Leeflang, Mariska M G
2015-03-11
Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.
Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup
2018-01-01
The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.
Sheynin, Jony; Moustafa, Ahmed A.; Beck, Kevin D.; Servatius, Richard J.; Myers, Catherine E.
2015-01-01
Exaggerated avoidance behavior is a predominant symptom in all anxiety disorders and its degree often parallels the development and persistence of these conditions. Both human and non-human animal studies suggest that individual differences as well as various contextual cues may impact avoidance behavior. Specifically, we have recently shown that female sex and inhibited temperament, two anxiety vulnerability factors, are associated with greater duration and rate of the avoidance behavior, as demonstrated on a computer-based task closely related to common rodent avoidance paradigms. We have also demonstrated that avoidance is attenuated by the administration of explicit visual signals during “non-threat” periods (i.e., safety signals). Here, we use a reinforcement-learning network model to investigate the underlying mechanisms of these empirical findings, with a special focus on distinct reward and punishment sensitivities. Model simulations suggest that sex and inhibited temperament are associated with specific aspects of these sensitivities. Specifically, differences in relative sensitivity to reward and punishment might underlie the longer avoidance duration demonstrated by females, whereas higher sensitivity to punishment might underlie the higher avoidance rate demonstrated by inhibited individuals. Simulations also suggest that safety signals attenuate avoidance behavior by strengthening the competing approach response. Lastly, several predictions generated by the model suggest that extinction-based cognitive-behavioral therapies might benefit from the use of safety signals, especially if given to individuals with high reward sensitivity and during longer safe periods. Overall, this study is the first to suggest cognitive mechanisms underlying the greater avoidance behavior observed in healthy individuals with different anxiety vulnerabilities. PMID:25639540
Liao, Pei-Hu; Lin, Ruey-Hseng; Yang, Ming-Ling; Li, Yi-Ching; Kuan, Yu-Hsiang
2012-03-01
Chinese hamster ovary (CHO) cells, its lung fibroblasts (V79), and human lymphocytes are routinely used in in vitro cytogenetic assays, which include micronuclei (MN), sister chromatid exchange (SCE), and chromosome aberration (CA) assays. Mitomycin C (MMC), a DNA cross-link alkylating agent, is both an anticancer medicine and a carcinogen. To study the differential representative values of cell types in MMC-treated cytogenetic assays and its upstream factor, cysteine aspartic acid-specific protease (caspase)-3. Among the chosen cell types, lymphocytes expressed the highest sensitivity in all three MMC-induced assays, whereas CHO and V79 showed varied sensitivity in different assays. In MN assay, the sensitivity of CHO is higher than or equal to V79; in SCE assay, the sensitivity of CHO is the same as V79; and in CA assay, the sensitivity of CHO is higher than V79. In-depth analysis of CA revealed that in chromatid breaks and dicentrics formation, lymphocyte was the most sensitive of all and CHO was more sensitive than V79; and in acentrics and interchanges formation, lymphocyte was much more sensitive than the others. Furthermore, we found caspase-3 activity plays an important role in MMC-induced cytogenetic assays, with MMC-induced caspase-3 activity resulting in more sensitivity in lymphocytes than in CHO and V79. Based on these findings, lymphocyte will make a suitable predictive or representative control reference in cytogenetic assays and caspase-3 activity with its high specificity, positive predictive value, and sensitivity.
Shojaei, Taha Roodbar; Mohd Salleh, Mohamad Amran; Tabatabaei, Meisam; Ekrami, Alireza; Motallebi, Roya; Rahmani-Cherati, Tavoos; Hajalilou, Abdollah; Jorfi, Raheleh
2014-01-01
Mycobacterium tuberculosis, the causing agent of tuberculosis, comes second only after HIV on the list of infectious agents slaughtering many worldwide. Due to the limitations behind the conventional detection methods, it is therefore critical to develop new sensitive sensing systems capable of quick detection of the infectious agent. In the present study, the surface modified cadmium-telluride quantum dots and gold nanoparticles conjunct with two specific oligonucleotides against early secretory antigenic target 6 were used to develop a sandwich-form fluorescence resonance energy transfer-based biosensor to detect M. tuberculosis complex and differentiate M. tuberculosis and M. bovis Bacille Calmette-Guerin simultaneously. The sensitivity and specificity of the newly developed biosensor were 94.2% and 86.6%, respectively, while the sensitivity and specificity of polymerase chain reaction and nested polymerase chain reaction were considerably lower, 74.2%, 73.3% and 82.8%, 80%, respectively. The detection limits of the sandwich-form fluorescence resonance energy transfer-based biosensor were far lower (10 fg) than those of the polymerase chain reaction and nested polymerase chain reaction (100 fg). Although the cost of the developed nanobiosensor was slightly higher than those of the polymerase chain reaction-based techniques, its unique advantages in terms of turnaround time, higher sensitivity and specificity, as well as a 10-fold lower detection limit would clearly recommend this test as a more appropriate and cost-effective tool for large scale operations. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-01-01
Objective: To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. Methods: A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. Results: 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83–0.88] and the specificity was 0.95 (0.93–0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44–0.51) and 0.37 (0.34–0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63–3.19). Conclusion: DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules. PMID:27759428
Assis, G B N; de Oliveira, T F; Gardner, I A; Figueiredo, H C P; Leal, C A G
2017-06-01
Despite the worldwide occurrence of Francisella noatunensis subsp. orientalis (Fno) infection in farmed tilapia, sensitivity and specificity estimates of commonly used diagnostic tests have not been reported. This study aimed to estimate the sensitivity and specificity of bacteriological culture and qPCR to detect Fno infection. We tested 559 fish, sampled from four farms with different epidemiological scenarios: (i) healthy fish in a hatchery free of Fno; (ii) targeted sampling of diseased fish with suggestive external clinical signs of francisellosis during an outbreak; (iii) convenience sampling of diseased and clinically healthy fish during an outbreak; and (iv) sampling of healthy fish in a cage farm without a history of outbreaks, but with francisellosis reported in other farms in the same reservoir. The qPCR had higher median sensitivity (range, 48.8-99.5%) than culture (range, 1.6-74.4%). Culture had a substantially lower median sensitivity (1.6%) than qPCR (48.8%) to detect Fno in carrier tilapia (farm 4). Median specificity estimates for both tests were >99.2%. The qPCR is the superior test for use in surveillance and monitoring programmes for francisellosis in farmed Nile tilapia, but both tests have high sensitivity and specificity which make them fit for use in the diagnosis of Fno outbreaks. © 2016 John Wiley & Sons Ltd.
Impaired temporal contrast sensitivity in dyslexics is specific to retain-and-compare paradigms.
Ben-Yehudah, G; Sackett, E; Malchi-Ginzberg, L; Ahissar, M
2001-07-01
Developmental dyslexia is a specific reading disability that affects 5-10% of the population. Recent studies have suggested that dyslexics may experience a deficit in the visual magnocellular pathway. The most extensively studied prediction deriving from this hypothesis is impaired contrast sensitivity to transient, low-luminance stimuli at low spatial frequencies. However, the findings are inconsistent across studies and even seemingly contradictory. In the present study, we administered several different paradigms for assessing temporal contrast sensitivity, and found both impaired and normal contrast sensitivity within the same group of dyslexic participants. Under sequential presentation, in a temporal forced choice paradigm, dyslexics showed impaired sensitivity to both drifting and flickering gratings. However, under simultaneous presentation, with a spatial forced choice paradigm, dyslexics' sensitivity did not differ from that of the controls. Within each paradigm, dyslexics' sensitivity was poorer at higher temporal frequencies, consistent with the magnocellular hypothesis. These results suggest that a basic perceptual impairment in dyslexics may be their limited ability to retain-and-compare perceptual traces across brief intervals.
Gong, LiJie; He, Yan; Tian, Peng; Yan, Yan
2016-07-01
To determine the effect of elastic strain rate ratio method and virtual touch tissue quantification (VTQ) on the diagnosis of breast masses. Sixty female patients with breast cancer, who received surgical treatment in Daqing Oilfield General Hospital, were enrolled. All patients signed the informed consent paperwork and they were treated by routine ultrasound examination, compression elastography (CE) examination, and VTQ examination in turn. Strain ratio (SR) was checked by CE and shear wave velocity (SWV) value was measured by VTQ. The diagnostic values of different methods were evaluated by receiver operating characteristic (ROC) curves in the diagnosis of benign and malignant breast tumors. The maximum diameter and SWV value of the benign tumors were lower than those of the malignant tumors, and the SR ratio of benign masses was higher than that of malignant tumors (P<0.01). The AUC, sensitivity and specificity for elastic strain rate and VTQ for single or combined use were higher than those of conventional ultrasound (0.904, 97.5%, 69.2%; 0.946, 87.5%, 87.2%; 0.976, 90%, 97.4% vs 0.783, 85%, 61.5%). The AUC and specificity of VTQ were higher than those of the elastic strain rate (0.946, 87.2% vs 0.904, 69.2%), but the sensitivity of VTQ was higher than that of the latter (87.5% vs 97.5%). The AUC and specificity for combination of both methods were higher than those of single method, but the sensitivity was lower than that of the elastic strain rate. Combination of elastic strain rate ratio method with VTQ possesses the best diagnostic value and the highest diagnostic accuracy in the diagnosis of breast mass than that used alone.
Comparative diagnostics of allergy using quantitative immuno-PCR and ELISA.
Simonova, Maria A; Pivovarov, Victor D; Ryazantsev, Dmitry Y; Dolgova, Anna S; Berzhets, Valentina M; Zavriev, Sergei K; Svirshchevskaya, Elena V
2018-05-01
Estimation of specific IgE is essential for the prevention of allergy progression. Quantitative immuno-PCR (qiPCR) can increase the sensitivity of IgE detection. We aimed to develop qiPCR and compare it to the conventional ELISA in identification of IgE to Alt a 1 and Fel d 1 allergens. Single stranded 60-mer DNA conjugated to streptavidin was used to detect antigen-IgE-biotin complex by qiPCR. In semi-logarithmic scale qiPCR data were linear in a full range of serum dilutions resulting in three- to ten-times higher sensitivity of qiPCR in comparison with ELISA in IgE estimation in low titer sera. Higher sensitivity of qiPCR in identification of low titer IgE is a result of a higher linearity of qiPCR data.
NASA Astrophysics Data System (ADS)
Hug, William F.; Bhartia, Rohit; Taspin, Alexandre; Lane, Arthur; Conrad, Pamela; Sijapati, Kripa; Reid, Ray D.
2005-11-01
Laser induced native fluorescence (LINF) is the most sensitive method of detection of biological material including microorganisms, virus', and cellular residues. LINF is also a sensitive method of detection for many non-biological materials as well. The specificity with which these materials can be classified depends on the excitation wavelength and the number and location of observation wavelengths. Higher levels of specificity can be obtained using Raman spectroscopy but a much lower levels of sensitivity. Raman spectroscopy has traditionally been employed in the IR to avoid fluorescence. Fluorescence rarely occurs at wavelength below about 270nm. Therefore, when excitation occurs at a wavelength below 250nm, no fluorescence background occurs within the Raman fingerprint region for biological materials. When excitation occurs within electronic resonance bands of the biological target materials, Raman signal enhancement over one million typically occurs. Raman sensitivity within several hundred times fluorescence are possible in the deep UV where most biological materials have strong absorption. Since the Raman and fluorescence emissions occur at different wavelength, both spectra can be observed simultaneously, thereby providing a sensor with unique sensitivity and specificity capability. We will present data on our integrated, deep ultraviolet, LINF/Raman instruments that are being developed for several applications including life detection on Mars as well as biochemical warfare agents on Earth. We will demonstrate the ability to discriminate organic materials based on LINF alone. Together with UV resonance Raman, higher levels of specificity will be demonstrated. In addition, these instruments are being developed as on-line chemical sensors for industrial and municipal waste streams and product quality applications.
Bhatia, Nirmanmoh; Abushora, Mohannad Y; Donneyong, Macarius M; Stoddard, Marcus F
2014-03-01
Patent foramen ovale (PFO) and intra-pulmonary shunt (IPS) are potential causes of stroke. The most optimum cardiac cycle cutoff for bubbles to appear in the left heart on saline contrast transthoracic echocardiography (TTE) as criteria to differentiate the 2 entities is unknown. Ninety-five adult patients had saline contrast transesophageal echocardiography (TEE), two-dimensional (2D) and 3DTTE. Sensitivity and specificity of each cardiac cycle as cutoff to differentiate a PFO and IPS were obtained. Transesophageal echocardiography showed IPS in 28 and PFO in 15 patients. If bubbles appeared in the left heart within the first 4 cardiac cycles (the 4th cardiac cycle rule) as compared to alternate cutoffs, a PFO was most accurately diagnosed by both 2D and 3DTTE. Bubbles appearing at or after the 5th cardiac cycle most accurately determined an IPS. 3D versus 2DTTE had a trend for a higher sensitivity (61% vs. 36%, P = 0.06), but similar specificity (94% vs. 91%) for IPS. Accuracy of 3DTTE was 84% and 2DTTE was 75% (P = 0.08) for IPS. For PFO, 2DTTE sensitivity (87%) and specificity (98%) did not differ (P = NS) from that of 3DTTE sensitivity (73%) and specificity (100%). This study demonstrates for the first time that the 4th cardiac cycle rule differentiates PFO and IPS most optimally by 2D and 3DTTE. 3DTTE appears to have higher sensitivity for diagnosing IPS. These data suggest that 3DTTE is preferable when IPS is to be diagnosed. Both methods are similar for diagnosing PFO. © 2013, Wiley Periodicals, Inc.
Cheng, Dan; Yu, Mengqun; Fu, Fei; Han, Weiye; Li, Gan; Xie, Jianping; Song, Yang; Swihart, Mark T; Song, Erqun
2016-01-05
Food poisoning and infectious diseases caused by pathogenic bacteria such as Staphylococcus aureus (SA) are serious public health concerns. A method of specific, sensitive, and rapid detection of such bacteria is essential and important. This study presents a strategy that combines aptamer and antibiotic-based dual recognition units with magnetic enrichment and fluorescent detection to achieve specific and sensitive quantification of SA in authentic specimens and in the presence of much higher concentrations of other bacteria. Aptamer-coated magnetic beads (Apt-MB) were employed for specific capture of SA. Vancomycin-stabilized fluorescent gold nanoclusters (AuNCs@Van) were prepared by a simple one-step process and used for sensitive quantification of SA in the range of 32-10(8) cfu/mL with the detection limit of 16 cfu/mL via a fluorescence intensity measurement. And using this strategy, about 70 cfu/mL of SA in complex samples (containing 3 × 10(8) cfu/mL of other different contaminated bacteria) could be successfully detected. In comparison to prior studies, the developed strategy here not only simplifies the preparation procedure of the fluorescent probes (AuNCs@Van) to a great extent but also could sensitively quantify SA in the presence of much higher concentrations of other bacteria directly with good accuracy. Moreover, the aptamer and antibiotic used in this strategy are much less expensive and widely available compared to common-used antibodies, making it cost-effective. This general aptamer- and antibiotic-based dual recognition strategy, combined with magnetic enrichment and fluorescent detection of trace bacteria, shows great potential application in monitoring bacterial food contamination and infectious diseases.
El-sayed, Dena; Grotts, Jonathan; Golgert, William A.; Sugar, Alan M.
2014-01-01
Background It is unclear whether procalcitonin is an accurate predictor of bacterial infections in patients with renal impairment, although it is used as a biomarker for early diagnosis of sepsis. We determined the sensitivity, specificity, positive and negative predictive values, accuracy and best predictive value of procalcitonin for predicting bacterial infection in adult patients with severe renal impairment. Methods Retrospective study at a single-center community teaching hospital involving 473 patients, ages 18–65, with Modification of Diet in Renal Disease eGFR ≤30 ml/min per 1.73 m2, admitted between January 2009 and June 2012, with 660 independent hospital visits. A positive or negative culture (blood or identifiable focus of infection) was paired to the highest procalcitonin result performed 48 hours before or after collecting the culture. Results The sensitivity and specificity to predict bacterial infection, using a procalcitonin level threshold of 0.5 ng/mL, was 0.80 and 0.35 respectively. When isolating for presence of bacteremia, the sensitivity and specificity were 0.89 and 0.35 respectively. An equation adjusting for optimum thresholds of procalcitonin levels for predicting bacterial infection at different levels of eGFR had a sensitivity and specificity of 0.55 and 0.80 respectively. Conclusions Procalcitonin is not a reliably sensitive or specific predictor of bacterial infection in patients with renal impairment when using a single threshold. Perhaps two thresholds should be employed, where below the lower threshold (i.e. 0.5 ng/mL) bacterial infection is unlikely with a sensitivity of 0.80, and above the higher threshold (i.e. 3.2 ng/mL) bacterial infection is very likely with a specificity of 0.75. PMID:25734138
El-Sayed, Dena; Grotts, Jonathan; Golgert, William A; Sugar, Alan M
2014-09-01
It is unclear whether procalcitonin is an accurate predictor of bacterial infections in patients with renal impairment, although it is used as a biomarker for early diagnosis of sepsis. We determined the sensitivity, specificity, positive and negative predictive values, accuracy and best predictive value of procalcitonin for predicting bacterial infection in adult patients with severe renal impairment. Retrospective study at a single-center community teaching hospital involving 473 patients, ages 18-65, with Modification of Diet in Renal Disease eGFR ≤30 ml/min per 1.73 m(2), admitted between January 2009 and June 2012, with 660 independent hospital visits. A positive or negative culture (blood or identifiable focus of infection) was paired to the highest procalcitonin result performed 48 hours before or after collecting the culture. The sensitivity and specificity to predict bacterial infection, using a procalcitonin level threshold of 0.5 ng/mL, was 0.80 and 0.35 respectively. When isolating for presence of bacteremia, the sensitivity and specificity were 0.89 and 0.35 respectively. An equation adjusting for optimum thresholds of procalcitonin levels for predicting bacterial infection at different levels of eGFR had a sensitivity and specificity of 0.55 and 0.80 respectively. Procalcitonin is not a reliably sensitive or specific predictor of bacterial infection in patients with renal impairment when using a single threshold. Perhaps two thresholds should be employed, where below the lower threshold (i.e. 0.5 ng/mL) bacterial infection is unlikely with a sensitivity of 0.80, and above the higher threshold (i.e. 3.2 ng/mL) bacterial infection is very likely with a specificity of 0.75.
Detection of Bacteriuria by Canine Olfaction
Maurer, Maureen; McCulloch, Michael; Willey, Angel M.; Hirsch, Wendi; Dewey, Danielle
2016-01-01
Background. Urinary tract infections (UTIs) are a significant medical problem , particularly for patients with neurological conditions and the elderly. Detection is often difficult in these patients, resulting in delayed diagnoses and more serious infections such as pyelonephritis and life-threatening sepsis. Many patients have a higher risk of UTIs because of impaired bladder function, catheterization, and lack of symptoms. Urinary tract infections are the most common nosocomial infection; however, better strategies are needed to improve early detection of the disease. Methods. In this double-blinded, case-control, validation study, we obtained fresh urine samples daily in a consecutive case series over a period of 16 weeks. Dogs were trained to distinguish urine samples that were culture-positive for bacteriuria from those of culture-negative controls, using reward-based clicker and treat methods. Results. Samples were obtained from 687 individuals (from 3 months to 92 years of age; 86% female and 14% male; 34% culture-positive and 66% culture-negative controls). Dogs detected urine samples positive for 100 000 colony-forming units/mL Escherichia coli (N = 250 trials; sensitivity 99.6%, specificity 91.5%). Dilution of E coli urine with distilled water did not affect accuracy at 1% (sensitivity 100%, specificity 91.1%) or 0.1% (sensitivity 100%, specificity 93.6%) concentration. Diagnostic accuracy was similar to Enterococcus (n = 50; sensitivity 100%, specificity 93.9%), Klebsiella (n = 50; sensitivity 100%, specificity 95.1%), and Staphylococcus aureus (n = 50; sensitivity 100%, specificity 96.3%). All dogs performed with similarly high accuracy: overall sensitivity was at or near 100%, and specificity was above 90%. Conclusions. Canine scent detection is an accurate and feasible method for detection of bacteriuria. PMID:27186578
Yu, J; Zhu, H T; Zhao, J J; Su, J Z; Xia, Y D
2017-05-08
Objective: To investigate the sorting effect of p16(INK4a)/Ki-67 double immunostaining method in patients with atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesion (LSIL) cytology results. Methods: Four-hundred and twenty cases collected during April 2014 to February 2015 of cervical cytology of ASCUS ( n =318) and LSIL ( n =102) were selected, and residual liquid-based cytology specimens were used for p16(INK4a)/Ki-67 double immunostaining. The sensitivity and specificity of the detection of cervical precancerous lesions and cervical cancer were calculated, and the results were compared with high risk HPV. Taking histological follow-up as the gold standard, the test was considered positive when at least one cell exhibited p16(INK4a)/Ki-67 co-staining, without requirement of adjunct morphologic interpretation of positive cells. Results: Further screening CIN2+ in cytology ASCUS and LSIL group , the sensitivity of p16(INK4a)/Ki-67 double immunostaining was slightly lower than high risk HPV (84.2% vs . 94.7%), while the specificity was higher (84.0% vs . 53.9%). For ASCUS patients, the sensitivity of p16(INK4a)/Ki-67 double immunostaining and high risk HPV was 82.6% and 91.3%, and the specificity was 88.8% and 63.7%, respectively. For LSIL patients, the sensitivity of p16(INK4a)/Ki-67 double immunostaining and high risk HPV was 86.7% and 100.0%, and the specificity was 67.8% and 20.7%, respectively. For patients younger and older than 30 years, specificity of p16(INK4a)/Ki-67 double immunostaining was both higher than that of high risk HPV (80.8% vs . 42.3%; 84.6% vs . 56.9%). Conclusions: p16(INK4a)/Ki-67 double immunostaining can effectively identify the high risk population in ASCUS or LSIL, with higher specificity than high risk HPV test. p16(INK4a)/Ki-67 double immunostaining may benefit patients younger than 30 years of age as a preliminary or potential cytology-combining screening tool.
Disorder-specific cognitive profiles in major depressive disorder and generalized anxiety disorder.
Hendriks, Sanne M; Licht, Carmilla M M; Spijker, Jan; Beekman, Aartjan T F; Hardeveld, Florian; de Graaf, Ron; Penninx, Brenda W J H
2014-04-01
This investigation examines differences in cognitive profiles in subjects with major depressive disorder (MDD) and generalized anxiety disorder (GAD). Data were used from subjects with current MDD (n = 655), GAD (n = 107) and comorbid MDD/GAD (n = 266) diagnosis from the Netherlands Study of Depression and Anxiety (NESDA). The Composite Interview Diagnostic Instrument was used to diagnose MDD and GAD. Cognitive profiles were measured using the Leiden Index of Depression Sensitivity, the Anxiety Sensitivity Index, and the Penn State Worry Questionnaire. Results showed that differences in cognitive profiles between single MDD and single GAD subjects were present: scores on hopelessness/suicidality and rumination were significantly higher in MDD than GAD, whereas anxiety sensitivity for physical concerns and pathological worry were higher in GAD than MDD. The cognitive profile of comorbid MDD/GAD showed more extreme depression cognitions compared to single disorders, and a similar anxiety profile compared to single GAD subjects. Despite the commonalities in cognitive profiles in MDD and GAD, there are differences suggesting that MDD and GAD have disorder-specific cognitive profiles. Findings of this investigation give support for models like the cognitive content-specificity model and the tripartite model and could provide useful handles for treatment focus.
Guzman, Maria G.; Jaenisch, Thomas; Gaczkowski, Roger; Ty Hang, Vo Thi; Sekaran, Shamala Devi; Kroeger, Axel; Vazquez, Susana; Ruiz, Didye; Martinez, Eric; Mercado, Juan C.; Balmaseda, Angel; Harris, Eva; Dimano, Efren; Leano, Prisca Susan A.; Yoksan, Sutee; Villegas, Elci; Benduzu, Herminia; Villalobos, Iris; Farrar, Jeremy; Simmons, Cameron P.
2010-01-01
Background Early diagnosis of dengue can assist patient triage and management and prevent unnecessary treatments and interventions. Commercially available assays that detect the dengue virus protein NS1 in the plasma/serum of patients offers the possibility of early and rapid diagnosis. Methodology/Principal Findings The sensitivity and specificity of the Pan-E Dengue Early ELISA and the Platelia™ Dengue NS1 Ag assays were compared against a reference diagnosis in 1385 patients in 6 countries in Asia and the Americas. Platelia was more sensitive (66%) than Pan-E (52%) in confirmed dengue cases. Sensitivity varied by geographic region, with both assays generally being more sensitive in patients from SE Asia than the Americas. Both kits were more sensitive for specimens collected within the first few days of illness onset relative to later time points. Pan-E and Platelia were both 100% specific in febrile patients without evidence of acute dengue. In patients with other confirmed diagnoses and healthy blood donors, Platelia was more specific (100%) than Pan-E (90%). For Platelia, when either the NS1 test or the IgM test on the acute sample was positive, the sensitivity versus the reference result was 82% in samples collected in the first four days of fever. NS1 sensitivity was not associated to disease severity (DF or DHF) in the Platelia test, whereas a trend for higher sensitivity in DHF cases was seen in the Pan-E test (however combined with lower overall sensitivity). Conclusions/Significance Collectively, this multi-country study suggests that the best performing NS1 assay (Platelia) had moderate sensitivity (median 64%, range 34–76%) and high specificity (100%) for the diagnosis of dengue. The poor sensitivity of the evaluated assays in some geographical regions suggests further assessments are needed. The combination of NS1 and IgM detection in samples collected in the first few days of fever increased the overall dengue diagnostic sensitivity. PMID:20824173
Huang, Terry T-K; Nansel, Tonja R.; Belsheim, Allen R.; Morrison, John A.
2008-01-01
Objective To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoffs in relation to adult MetS. Study design Data from the NHLBI Lipid Research Clinics (LRC) Princeton Prevalence Study (1973–76) and the Princeton Follow-up Study (PFS, 2000-4) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff, as well as for aggregates of components. Results Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all five pediatric MetS components were considered, the presence of at least one abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Conclusions Considering multiple metabolic variables in childhood can improve the predictive utility for adult MetS, compared to each component or body mass alone. MetS variables may be useful for identifying some at risk children for prevention interventions. PMID:18206687
Banal, F; Dougados, M; Combescure, C; Gossec, L
2009-07-01
To evaluate the ability of the widely used ACR set of criteria (both list and tree format) to diagnose RA compared with expert opinion according to disease duration. A systematic literature review was conducted in PubMed and Embase databases. All articles reporting the prevalence of RA according to ACR criteria and expert opinion in cohorts of early (<1 year duration) or established (>1 year) arthritis were analysed to calculate the sensitivity and specificity of ACR 1987 criteria against the "gold standard" (expert opinion). A meta-analysis using a summary receiver operating characteristic (SROC) curve was performed and pooled sensitivity and specificity were calculated with confidence intervals. Of 138 publications initially identified, 19 were analysable (total 7438 patients, 3883 RA). In early arthritis, pooled sensitivity and specificity of the ACR set of criteria were 77% (68% to 84%) and 77% (68% to 84%) in the list format versus 80% (72% to 88%) and 33% (24% to 43%) in the tree format. In established arthritis, sensitivity and specificity were respectively 79% (71% to 85%) and 90% (84% to 94%) versus 80% (71% to 85%) and 93% (86% to 97%). The SROC meta-analysis confirmed the statistically significant differences, suggesting that diagnostic performances of ACR list criteria are better in established arthritis. The specificity of ACR 1987 criteria in early RA is low, and these criteria should not be used as diagnostic tools. Sensitivity and specificity in established RA are higher, which reflects their use as classification criteria gold standard.
Cabañas, R; Calderón, O; Ramírez, E; Fiandor, A; Caballero, T; Heredia, R; Herranz, P; Madero, R; Quirce, S; Bellón, T
2018-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a severe delayed hypersensitivity reaction. The determination of drug causality is complex. The lymphocyte transformation test (LTT) has been reported positive in more than 50% of DRESS cases. Nevertheless, the sensitivity and specificity of LTT specifically in DRESS have not yet been established. Rechallenge with the culprit drug is contraindicated and cannot be used as gold standard for sensitivity and specificity determination. To estimate the sensitivity and specificity of LTT in a clinically defined series of patients with DRESS. Some 41 patients diagnosed with DRESS were included in the study. The results of the algorithm of the Spanish Pharmacovigilance System were used as the standard for a correct diagnosis of drug causality. A standard LTT was performed with involved drugs in acute or recovery samples. A stimulation index (SI) ≥2 in at least one concentration except for beta-lactams (SI ≥3) and contrast media (SI ≥4) was considered positive. Contingency tables and ROC curves were used for analysis. Sensitivity and specificity of LTT in the recovery phase of DRESS were 73% and 82%, respectively, whereas in the acute phase, they were only 40% and 30%, respectively. Comparison of skin tests and LTT confirmed a higher sensitivity and specificity of LTT in DRESS. LTT showed high sensitivity (S) and specificity (Sp) for anticonvulsants (S 100%, Sp 100%; P = .008), anti-TB drugs (S 87.5%, Sp 100%; P = .004), and beta-lactams (S 73%, Sp 100%; P = .001). ROC curves revealed that the best criteria for LTT positivity for all drugs are SI ≥2 in at least one concentration, increasing overall sensitivity to 80%, and for beta-lactams from 73% to 92%. LTT is a good diagnostic tool for drug causality in DRESS, mainly when performed in the recovery phase. © 2017 John Wiley & Sons Ltd.
Child–Pugh Versus MELD Score for the Assessment of Prognosis in Liver Cirrhosis
Peng, Ying; Qi, Xingshun; Guo, Xiaozhong
2016-01-01
Abstract Child–Pugh and MELD scores have been widely used for the assessment of prognosis in liver cirrhosis. A systematic review and meta-analysis aimed to compare the discriminative ability of Child–Pugh versus MELD score to assess the prognosis of cirrhotic patients. PubMed and EMBASE databases were searched. The statistical results were summarized from every individual study. The summary areas under receiver operating characteristic curves, sensitivities, specificities, positive and negative likelihood ratios, and diagnostic odds ratios were also calculated. Of the 1095 papers initially identified, 119 were eligible for the systematic review. Study population was heterogeneous among studies. They included 269 comparisons, of which 44 favored MELD score, 16 favored Child–Pugh score, 99 did not find any significant difference between them, and 110 did not report the statistical significance. Forty-two papers were further included in the meta-analysis. In patients with acute-on-chronic liver failure, Child–Pugh score had a higher sensitivity and a lower specificity than MELD score. In patients admitted to ICU, MELD score had a smaller negative likelihood ratio and a higher sensitivity than Child–Pugh score. In patients undergoing surgery, Child–Pugh score had a higher specificity than MELD score. In other subgroup analyses, Child–Pugh and MELD scores had statistically similar discriminative abilities or could not be compared due to the presence of significant diagnostic threshold effects. Although Child–Pugh and MELD scores had similar prognostic values in most of cases, their benefits might be heterogeneous in some specific conditions. The indications for Child–Pugh and MELD scores should be further identified. PMID:26937922
[Comparison of Dengue viral nonstructural protein 1 antigen testing kits].
Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F
2018-02-06
Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.
Deciphering the Sensitivity and Specificity of the Implantable Doppler in Free Flap Monitoring.
Chang, Edward I; Ibrahim, Amir; Zhang, Hong; Liu, Jun; Nguyen, Alexander T; Reece, Gregory P; Yu, Peirong
2015-11-19
The efficacy of implantable Dopplers (iD) remains an area of considerable debate. Our study aims to decipher the sensitivity and specificity of the iD for free flap monitoring. A retrospective review of all free flaps with an iD was performed between 2000-2012. A Cook-Swartz iD was used in 439 patients (head and neck: n=364, breast: n=53, and extremity: n=22), and demonstrated equivalent sensitivity and specificity between flap types. The overall sensitivity and specificity was 77.8% and 88.4% respectively. The iD was placed on the artery in 267 patients, the vein in 101 patients, and 71 patients had a Doppler placed on both the artery and vein with significantly greater specificity for monitoring the artery than the vein (94.2% vs. 74.0%, p<0.001), but no difference between monitoring both the artery and the vein. Venous monitoring was significantly associated with a takeback (OR: 3.17, CI: 1.70-5.91; p=0.0003). There were 284 flaps that also had a monitoring segment in addition to the iD which significantly increased specificity for microvascular complications (OR: 17.71, CI: 3.39-92.23; p=0.0006). The specificity (90.5% vs. 84.8%) and sensitivity (80.0% vs. 66.7%) were significantly higher for clinically monitored flaps. The takeback rate was 13.0%, with positive findings in 59.6%, and 5.2% total flap loss. The use of implantable Dopplers has high sensitivity and specificity for buried free flap despite positive findings in less than 60% of take backs. Monitoring the artery is preferable to the vein, but clinical exam remains the gold standard for flap monitoring.
Chang, Edward I; Ibrahim, Amir; Zhang, Hong; Liu, Jun; Nguyen, Alexander T; Reece, Gregory P; Yu, Peirong
2016-03-01
The efficacy of implantable Doppler probes remains an area of considerable debate. This study aims to decipher its sensitivity and specificity for free flap monitoring. A retrospective review of all free flaps with an implantable Doppler probe was performed between 2000 and 2012. A Cook-Swartz implantable Doppler probe was used in 439 patients (head and neck, n = 364; breast, n = 53; extremity, n = 22), and demonstrated equivalent sensitivity and specificity between flap types. The overall sensitivity and specificity were 77.8 percent and 88.4 percent, respectively. The artery was monitored in 267 patients, compared to venous monitoring in 101 patients, and in 71 patients both the artery and vein were monitored. Arterial monitoring had significantly greater specificity than venous monitoring, (94.2 percent versus 74.0 percent; p < 0.001), but no benefit was found in monitoring both the artery and the vein. Venous monitoring was significantly associated with reoperation (OR, 3.17; 95 percent CI, 1.70 to 5.91; p = 0.0003). There were 284 flaps that had a monitoring segment in addition to the implantable Doppler probe that significantly increased overall specificity for microvascular complications (OR, 17.71; 95 percent CI, 3.39 to 92.23; p = 0.0006). The specificity (90.5 percent versus 84.8 percent) and sensitivity (80.0 percent versus 66.7 percent) were significantly higher for clinically monitored flaps. The take-back rate was 13.0 percent, with positive findings in 59.6 percent, and 5.2 percent total flap loss. The use of implantable Doppler probes has high sensitivity and specificity for buried free flaps despite positive findings in less than 60 percent of take-backs. Monitoring the artery is recommended, but clinical examination remains the gold standard for flap monitoring. Diagnostic, IV.
Evangelista, Laura; Cuocolo, Alberto; Pace, Leonardo; Mansi, Luigi; Del Vecchio, Silvana; Miletto, Paolo; Sanfilippo, Silvia; Pellegrino, Sara; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Salvatore, Marco; Galicchio, Rosj; Zuffante, Michele; Annunziata, Salvatore; Farsad, Mohsen; Chiaravalloti, Agostino; Spadafora, Marco
2018-05-07
The aim of this study was to determine the performance of 18 F-FDG-PET/CT in patients with solitary pulmonary nodule (SPN), stratifying the risk according to the likelihood of pulmonary malignancy. FDG-PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. FDG uptake in SPN was assessed by a 4-point scoring system and semiquantitative analysis using the ratio between SUVmax in SPN and SUVmean in mediastinal blood pool (BP) and between SUVmax in SPN and SUVmean in liver (L). Histopathology and/or follow-up data were used as standard of reference. SPN was malignant in 180 (36%) patients, benign in 175 (35%), and indeterminate in 147 (29%). The 355 patients with a definitive SPN nature (malignant or benign) were considered for the analysis. Considering FDG uptake ≥ 2, sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and accuracy were 85.6%, 85.7%, 86%, 85.2%, and 85.6% respectively. Sensitivity and PPV were higher (P < 0.05) in intermediate and high-risk patients, while specificity and NPV were higher (P < 0.05) in low-risk patients. On receiver operating characteristic curve analysis, the cut-offs for better discrimination between benign and malignant SPN were 1.56 (sensitivity 81% and specificity 87%) and 1.12 (sensitivity 81% and specificity 86%) for SUVmax/SUVmeanBP and SUVmax/SUVmeanL respectively. In intermediate and high-risk patients, including the SUVmax/SUVmeanBP, the specificity shifted from 85% and 50% to 100%. Visual FDG-PET/CT has an acceptable performance in patients with SPN, but accuracy improves when SUVratios are considered, particularly in patients with intermediate and high risk of malignancy.
Partovi, Sasan; Yuh, Roger; Pirozzi, Sara; Lu, Ziang; Couturier, Spencer; Grosse, Ulrich; Schluchter, Mark D; Nelson, Aaron; Jones, Robert; O’Donnell, James K; Faulhaber, Peter
2017-01-01
The objective of this study was to assess the ability of a quantitative software-aided approach to improve the diagnostic accuracy of 18F FDG PET for Alzheimer’s dementia over visual analysis alone. Twenty normal subjects (M:F-12:8; mean age 80.6 years) and twenty mild AD subjects (M:F-12:8; mean age 70.6 years) with 18F FDG PET scans were obtained from the ADNI database. Three blinded readers interpreted these PET images first using a visual qualitative approach and then using a quantitative software-aided approach. Images were classified on two five-point scales based on normal/abnormal (1-definitely normal; 5-definitely abnormal) and presence of AD (1-definitely not AD; 5-definitely AD). Diagnostic sensitivity, specificity, and accuracy for both approaches were compared based on the aforementioned scales. The sensitivity, specificity, and accuracy for the normal vs. abnormal readings of all readers combined were higher when comparing the software-aided vs. visual approach (sensitivity 0.93 vs. 0.83 P = 0.0466; specificity 0.85 vs. 0.60 P = 0.0005; accuracy 0.89 vs. 0.72 P<0.0001). The specificity and accuracy for absence vs. presence of AD of all readers combined were higher when comparing the software-aided vs. visual approach (specificity 0.90 vs. 0.70 P = 0.0008; accuracy 0.81 vs. 0.72 P = 0.0356). Sensitivities of the software-aided and visual approaches did not differ significantly (0.72 vs. 0.73 P = 0.74). The quantitative software-aided approach appears to improve the performance of 18F FDG PET for the diagnosis of mild AD. It may be helpful for experienced 18F FDG PET readers analyzing challenging cases. PMID:28123864
Huy, Nguyen Tien; Thao, Nguyen Thanh Hong; Tuan, Nguyen Anh; Khiem, Nguyen Tuan; Moore, Christopher C.; Thi Ngoc Diep, Doan; Hirayama, Kenji
2012-01-01
Background and Purpose Successful outcomes from bacterial meningitis require rapid antibiotic treatment; however, unnecessary treatment of viral meningitis may lead to increased toxicities and expense. Thus, improved diagnostics are required to maximize treatment and minimize side effects and cost. Thirteen clinical decision rules have been reported to identify bacterial from viral meningitis. However, few rules have been tested and compared in a single study, while several rules are yet to be tested by independent researchers or in pediatric populations. Thus, simultaneous test and comparison of these rules are required to enable clinicians to select an optimal diagnostic rule for bacterial meningitis in settings and populations similar to ours. Methods A retrospective cross-sectional study was conducted at the Infectious Department of Pediatric Hospital Number 1, Ho Chi Minh City, Vietnam. The performance of the clinical rules was evaluated by area under a receiver operating characteristic curve (ROC-AUC) using the method of DeLong and McNemar test for specificity comparison. Results Our study included 129 patients, of whom 80 had bacterial meningitis and 49 had presumed viral meningitis. Spanos's rule had the highest AUC at 0.938 but was not significantly greater than other rules. No rule provided 100% sensitivity with a specificity higher than 50%. Based on our calculation of theoretical sensitivity and specificity, we suggest that a perfect rule requires at least four independent variables that posses both sensitivity and specificity higher than 85–90%. Conclusions No clinical decision rules provided an acceptable specificity (>50%) with 100% sensitivity when applying our data set in children. More studies in Vietnam and developing countries are required to develop and/or validate clinical rules and more very good biomarkers are required to develop such a perfect rule. PMID:23209715
Rodríguez Cruz, Pedro M; Luo, Yue-Bei; Miller, James; Junckerstorff, Reimar C; Mastaglia, Frank L; Fabian, Victoria
2014-12-01
Although there have been several previous reports of immunohistochemical staining for MHC antigens in muscle biopsies, there appears to be a lack of consensus about its routine use in the diagnostic evaluation of biopsies from patients with suspected inflammatory myopathy. Positive MHC-I staining is nonspecific but is widely used as a marker for inflammatory myopathy, whilst the role of MHC-II staining is not clearly defined. We investigated the sensitivity and specificity of MHC-I and MHC-II immunostaining for the diagnosis of inflammatory myopathy in a large group of biopsies from a single reference laboratory. Positive staining for MHC-I was found to have a high sensitivity in biopsies from patients with inflammatory myopathy but a very low specificity, as it was also common in other non-inflammatory myopathies and neurogenic disorders. On the other hand, MHC-II positivity had a much higher specificity in all major subgroups of inflammatory myopathy, especially inclusion body myositis. The findings indicate that the combination of MHC-I and MHC-II staining results in a higher degree of specificity for the diagnosis of inflammatory myopathy and that in biopsies with inflammation, positive MHC-II staining strongly supports the diagnosis of an immune-mediated myopathy. We recommend that immunohistochemical staining for both MHC-I and MHC-II should be included routinely in the diagnostic evaluation of muscle biopsies from patients with suspected inflammatory myopathy. However, as the sensitivity and interpretation of MHC staining may depend on the technique used, further studies are needed to compare procedures in different centres and develop standardised protocols. Copyright © 2014 Elsevier B.V. All rights reserved.
Huy, Nguyen Tien; Thao, Nguyen Thanh Hong; Tuan, Nguyen Anh; Khiem, Nguyen Tuan; Moore, Christopher C; Thi Ngoc Diep, Doan; Hirayama, Kenji
2012-01-01
Successful outcomes from bacterial meningitis require rapid antibiotic treatment; however, unnecessary treatment of viral meningitis may lead to increased toxicities and expense. Thus, improved diagnostics are required to maximize treatment and minimize side effects and cost. Thirteen clinical decision rules have been reported to identify bacterial from viral meningitis. However, few rules have been tested and compared in a single study, while several rules are yet to be tested by independent researchers or in pediatric populations. Thus, simultaneous test and comparison of these rules are required to enable clinicians to select an optimal diagnostic rule for bacterial meningitis in settings and populations similar to ours. A retrospective cross-sectional study was conducted at the Infectious Department of Pediatric Hospital Number 1, Ho Chi Minh City, Vietnam. The performance of the clinical rules was evaluated by area under a receiver operating characteristic curve (ROC-AUC) using the method of DeLong and McNemar test for specificity comparison. Our study included 129 patients, of whom 80 had bacterial meningitis and 49 had presumed viral meningitis. Spanos's rule had the highest AUC at 0.938 but was not significantly greater than other rules. No rule provided 100% sensitivity with a specificity higher than 50%. Based on our calculation of theoretical sensitivity and specificity, we suggest that a perfect rule requires at least four independent variables that posses both sensitivity and specificity higher than 85-90%. No clinical decision rules provided an acceptable specificity (>50%) with 100% sensitivity when applying our data set in children. More studies in Vietnam and developing countries are required to develop and/or validate clinical rules and more very good biomarkers are required to develop such a perfect rule.
Rahman, Muhammad Aziz; Spurrier, Nicola; Mahmood, Mohammad Afzal; Rahman, Mahmudur; Choudhury, Sohel Reza; Leeder, Stephen
2013-01-01
Aim/objectives The study aimed to validate the Rose Angina Questionnaire (RAQ) to detect coronary heart disease (CHD) by comparing with cardiologists' diagnoses in Bangladesh. Methods Patients aged 40–75 years attending to two cardiac hospitals were diagnosed as either CHD positive or CHD negative by cardiologists. The RAQ was used to reclassify them into CHD positive [RAQ] and CHD negative [RAQ]. Findings There were 302 CHD positive [cardiologists] and 302 CHD negative [cardiologists] individuals. The RAQ reclassified 194 individuals as CHD positive [RAQ] and 409 individuals as CHD negative [RAQ]. Therefore, the RAQ had 53% sensitivity and 89% specificity. There was no difference in sensitivity and specificity during subgroup analyzes by age and gender; the sensitivity was higher among people from lower socio-economic status. Conclusion The RAQ, having moderate sensitivity but high specificity to detect CHD, can be used to screen individuals at risk of CHD in large-scale epidemiological surveys. PMID:23438610
Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E; Kim, Soon Ae; Takahashi, Hideyuki; Ohnishi, Makoto; Anh, Dang Duc; Dong, Bai Qing; Kim, Jung Soo; Tomono, Jun; Miyamoto, Shigehiko; Notomi, Tsugunori; Kim, Dong Wook; Seki, Mitsuko
2015-01-01
Neisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF). We developed a meningococcal LAMP assay (Nm LAMP) that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z) and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR). The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively. Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.
Umanodan, Tomokazu; Fukukura, Yoshihiko; Kumagae, Yuichi; Shindo, Toshikazu; Nakajo, Masatoyo; Takumi, Koji; Nakajo, Masanori; Hakamada, Hiroto; Umanodan, Aya; Yoshiura, Takashi
2017-04-01
To determine the diagnostic performance of apparent diffusion coefficient (ADC) histogram analysis in diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiating adrenal adenoma from pheochromocytoma. We retrospectively evaluated 52 adrenal tumors (39 adenomas and 13 pheochromocytomas) in 47 patients (21 men, 26 women; mean age, 59.3 years; range, 16-86 years) who underwent DW 3.0T MRI. Histogram parameters of ADC (b-values of 0 and 200 [ADC 200 ], 0 and 400 [ADC 400 ], and 0 and 800 s/mm 2 [ADC 800 ])-mean, variance, coefficient of variation (CV), kurtosis, skewness, and entropy-were compared between adrenal adenomas and pheochromocytomas, using the Mann-Whitney U-test. Receiver operating characteristic (ROC) curves for the histogram parameters were generated to differentiate adrenal adenomas from pheochromocytomas. Sensitivity and specificity were calculated by using a threshold criterion that would maximize the average of sensitivity and specificity. Variance and CV of ADC 800 were significantly higher in pheochromocytomas than in adrenal adenomas (P < 0.001 and P = 0.001, respectively). With all b-value combinations, the entropy of ADC was significantly higher in pheochromocytomas than in adrenal adenomas (all P ≤ 0.001), and showed the highest area under the ROC curve among the ADC histogram parameters for diagnosing adrenal adenomas (ADC 200 , 0.82; ADC 400 , 0.87; and ADC 800 , 0.92), with sensitivity of 84.6% and specificity of 84.6% (cutoff, ≤2.82) with ADC 200 ; sensitivity of 89.7% and specificity of 84.6% (cutoff, ≤2.77) with ADC 400 ; and sensitivity of 94.9% and specificity of 92.3% (cutoff, ≤2.67) with ADC 800 . ADC histogram analysis of DW MRI can help differentiate adrenal adenoma from pheochromocytoma. 3 J. Magn. Reson. Imaging 2017;45:1195-1203. © 2016 International Society for Magnetic Resonance in Medicine.
Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J
2017-02-08
Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity of the former; higher specificity of the latter) were also not affected by ethnicity.
Raji, Cyrus A; Willeumier, Kristen; Taylor, Derek; Tarzwell, Robert; Newberg, Andrew; Henderson, Theodore A; Amen, Daniel G
2015-09-01
PTSD and TBI are two common conditions in veteran populations that can be difficult to distinguish clinically. The default mode network (DMN) is abnormal in a multitude of neurological and psychiatric disorders. We hypothesize that brain perfusion SPECT can be applied to diagnostically separate PTSD from TBI reliably in a veteran cohort using DMN regions. A group of 196 veterans (36 with PTSD, 115 with TBI, 45 with PTSD/TBI) were selected from a large multi-site population cohort of individuals with psychiatric disease. Inclusion criteria were peacetime or wartime veterans regardless of branch of service and included those for whom the traumatic brain injury was not service related. SPECT imaging was performed on this group both at rest and during a concentration task. These measures, as well as the baseline-concentration difference, were then inputted from DMN regions into separate binary logistic regression models controlling for age, gender, race, clinic site, co-morbid psychiatric diseases, TBI severity, whether or not the TBI was service related, and branch of armed service. Predicted probabilities were then inputted into a receiver operating characteristic analysis to compute sensitivity, specificity, and accuracy. Compared to PSTD, persons with TBI were older, male, and had higher rates of bipolar and major depressive disorder (p < 0.05). Baseline quantitative regions with SPECT separated PTSD from TBI in the veterans with 92 % sensitivity, 85 % specificity, and 94 % accuracy. With concentration scans, there was 85 % sensitivity, 83 % specificity and 89 % accuracy. Baseline-concentration (the difference metric between the two scans) scans were 85 % sensitivity, 80 % specificity, and 87 % accuracy. In separating TBI from PTSD/TBI visual readings of baseline scans had 85 % sensitivity, 81 % specificity, and 83 % accuracy. Concentration scans had 80 % sensitivity, 65 % specificity, and 79 % accuracy. Baseline-concentration scans had 82 % sensitivity, 69 % specificity, and 81 % accuracy. For separating PTSD from PTSD/TBI baseline scans had 87 % sensitivity, 83 % specificity, and 92 % accuracy. Concentration scans had 91 % sensitivity, 76 % specificity, and 88 % accuracy. Baseline-concentration scans had 84 % sensitivity, 64 % specificity, and 85 % accuracy. This study demonstrates the ability to separate PTSD and TBI from each other in a veteran population using functional neuroimaging.
Jung, Na Young; Kim, Sung Hoon; Kim, Sung Hun; Seo, Ye Young; Oh, Jin Kyoung; Choi, Hyun Su; You, Won Jong
2015-03-01
We evaluated the utility of magnetic resonance imaging (MRI) and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) for the preoperative staging of invasive lobular carcinoma (ILC) of the breast and compared the results with those of invasive ductal carcinoma (IDC). The study included pathologically proven 32 ILCs and 73 IDCs. We compared clinical and histopathological characteristics and the diagnostic performances of MRI and (18)F-FDG PET/CT for the primary mass, additional ipsilateral and/or contralateral lesion(s), and axillary lymph node metastasis between the ILC and IDC groups. Primary ILCs were greater in size, but demonstrated lower maximum standardized uptake values than IDCs. All primary masses were detected on MRI. The detection rate for ILCs (75.0%) was lower than that for IDCs (83.6%) on (18)F-FDG PET/CT, but the difference was not significant. For additional ipsilateral lesion(s), the sensitivities and specificities of MRI were 87.5% and 58.3% for ILC and 100.0% and 66.7% for IDC, respectively; whereas the sensitivities and specificities of (18)F-FDG PET/CT were 0% and 91.7% for ILC and 37.5% and 94.7% for IDC, respectively. The sensitivity of (18)F-FDG PET/CT for ipsilateral lesion(s) was significantly lower in the ILC group than the IDC group. The sensitivity for ipsilateral lesion(s) was significantly higher with MRI; however, specificity was higher with (18)F-FDG PET/CT in both tumor groups. There was no significant difference in the diagnostic performance for additional contralateral lesion(s) or axillary lymph node metastasis on MRI or (18)F-FDG PET/CT for ILC versus IDC. The MRI and (18)F-FDG PET/CT detection rates for the primary cancer do not differ between the ILC and IDC groups. Although (18)F-FDG PET/CT demonstrates lower sensitivity for primary and additional ipsilateral lesions, it shows higher specificity for additional ipsilateral lesions, and could play a complementary role in the staging of ILC as well as IDC.
Zhang, Hai-Chun; Hu, Rong-Fei; Zhu, Ting; Tong, Ling; Zhang, Qiu-Qin
2016-01-01
AIM: To evaluate the assessment of primary biliary cirrhosis degree by acoustic radiation force impulse imaging (ARFI) and hepatic fibrosis indicators. METHODS: One hundred and twenty patients who developed liver cirrhosis secondary to primary biliary cirrhosis were selected as the observation group, with the degree of patient liver cirrhosis graded by Child-Pugh (CP) score. Sixty healthy individuals were selected as the control group. The four indicators of hepatic fibrosis were detected in all research objects, including hyaluronic acid (HA), laminin (LN), type III collagen (PC III), and type IV collagen (IV-C). The liver parenchyma hardness value (LS) was then measured by ARFI technique. LS and the four indicators of liver fibrosis (HA, LN, PC III, and IV-C) were observed in different grade CP scores. The diagnostic value of LS and the four indicators of liver fibrosis in determining liver cirrhosis degree with PBC, whether used alone or in combination, were analyzed by receiver operating characteristic (ROC) curve. RESULTS: LS and the four indicators of liver fibrosis within the three classes (A, B, and C) of CP scores in the observation group were higher than in the control group, with C class > B class > A class; the differences were statistically significant (P < 0.01). Although AUC values of LS within the three classes of CP scores were higher than in the four indicators of liver fibrosis, sensitivity and specificity were unstable. The ROC curves of LS combined with the four indicators of liver fibrosis revealed that: AUC and sensitivity in all indicators combined in the A class of CP score were higher than in LS alone, albeit with slightly decreased specificity; AUC and specificity in all indicators combined in the B class of CP score were higher than in LS alone, with unchanged sensitivity; AUC values (0.967), sensitivity (97.4%), and specificity (90%) of all indicators combined in the C class of CP score were higher than in LS alone (0.936, 92.1%, 83.3%). CONCLUSION: The diagnostic value of PBC cirrhosis degree in liver cirrhosis degree assessment by ARFI combined with the four indicators of serum liver fibrosis is of satisfactory effectiveness and has important clinical application value. PMID:27298571
Khanna, Ashish; Khanna, Menka; Gill, Karamjit Singh
2015-11-01
Typhoid fever remains a significant health problem in endemic countries like India. Various serological tests for the diagnosis of typhoid fever are available commercially. We assessed the usefulness of rapid test based on magnetic particle separation to detect Immunoglobulin against Salmonella typhi O9 lipopolysaccharide. Aim of this study was to compare the sensitivity and specificity of widal test, typhidot and tubex TF test for the diagnosis of typhoid fever in an endemic country like India. Serum samples collected from 50 patients of typhoid fever, 50 patients of non typhoid fever and 100 normal healthy individuals residing in Amritsar were subjected to widal test, typhidot test and tubex TF test as per manufacturer's instructions. Data collected was assessed to find sensitivity and specificity of these tests in an endemic area. Significant widal test results were found positive in 68% of patients of typhoid fever and only 4% of non typhoid fever patients. Typhidot (IgM or IgG) was positive in 72% of typhoid fever patients and 10% and 6% in non typhoid fever and normal healthy individuals respectively. Tubex TF showed higher sensitivity of 76% and specificity of 96-99% which was higher than typhidot and comparable to widal test. This was the first evaluation of rapid tubex TF test in northern India. In countries which can afford high cost of test, tubex TF should be recommended for the diagnosis in acute stage of the disease in clinical setting. However, there is urgent need for a highly specific and sensitive test for the diagnosis of typhoid fever in clinical settings in endemic areas.
Salavati, M; Waninge, A; Rameckers, E A A; van der Steen, J; Krijnen, W P; van der Schans, C P; Steenbergen, B
2017-01-01
The objectives of this study were (i) to develop two cerebral visual impairment motor questionnaires (CVI-MQ's) for children with cerebral palsy (CP): one for children with Gross Motor Function Classification System (GMFCS) levels I, II and III and one for children with GMFCS levels IV and V; (ii) to describe their face validity and usability; and (iii) to determine their sensitivity and specificity. The initial versions of the two CVI-MQ's were developed based on literature. Subsequently, the Delphi method was used in two groups of experts, one familiar with CVI and one not familiar with CVI, in order to gain consensus about face validity and usability. The sensitivity and specificity of the CVI-MQ's were subsequently assessed in 82 children with CP with (n = 39) and without CVI (n = 43). With the receiver operating curve the cut-off scores were determined to detect possible presence or absence of CVI in children with CP. Both questionnaires showed very good face validity (percentage agreement above 96%) and good usability (percentage agreement 95%) for practical use. The CVI-MQ version for GMFCS levels I, II and III had a sensitivity of 1.00 and specificity of 0.96, with a cut-off score of 12 points or higher, and the version for GMFCS levels IV and V had a sensitivity of 0.97 and a specificity of 0.98, with a cut-off score of eight points or higher. The CVI-MQ is able to identify at-risk children with CP for the probability of having CVI. © 2016 John Wiley & Sons Ltd.
Hermann, Olena; Schmidt, Simone B; Boltzmann, Melanie; Rollnik, Jens D
2018-05-01
To calculate scale performance of the newly developed Hessisch Oldendorf Fall Risk Scale (HOSS) for classifying fallers and non-fallers in comparison with the Risk of Falling Scale by Huhn (FSH), a frequently used assessment tool. A prospective observational trail was conducted. The study was performed in a large specialized neurological rehabilitation facility. The study population ( n = 690) included neurological and neurosurgery patients during neurological rehabilitation with varying levels of disability. Around the half of the study patients were independent and dependent in the activities of daily living (ADL), respectively. Fall risk of each patient was assessed by HOSS and FSH within the first seven days after admission. Event of fall during rehabilitation was compared with HOSS and FSH scores as well as the according fall risk. Scale performance including sensitivity and specificity was calculated for both scales. A total of 107 (15.5%) patients experienced at least one fall. In general, fallers were characterized by an older age, a prolonged length of stay, and a lower Barthel Index (higher dependence in the ADL) on admission than non-fallers. The verification of fall prediction for both scales showed a sensitivity of 83% and a specificity of 64% for the HOSS scale, and a sensitivity of 98% with a specificity of 12% for the FSH scale, respectively. The HOSS shows an adequate sensitivity, a higher specificity and therefore a better scale performance than the FSH. Thus, the HOSS might be superior to existing assessments.
Keller, Marla J; Buckley, Niall; Katzen, Lauren L; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C; Einstein, Mark H
2013-12-01
Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or presex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Healthy monogamous couples received Microlax-type applicators (Tectubes, Åstorp, Sweden) filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert 1 dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen, followed by UV then DSA, and scored by 2 readers. Positive and negative controls were randomly included in applicator batches. Fifteen couples completed the study. Each woman returned at least 6 applicators over a 30-day period. The sensitivity for insertion of postsex applicators was higher for UV (97%) compared with DSA (90%), and the specificity was similar (≥96%). For presex applicators, the sensitivity and specificity were higher for DSA (100%) compared with UV testing (87% sensitivity, 96% specificity). Among returned postsex applicators, 95% tested positive by UV compared with 87% by DSA. Agreement between readers was significantly better on the presex applicators for DSA than for UV, and for postsex readings, agreement was less than half that for UV, although the results were not statistically significant. Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex.
Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura
2010-03-01
This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.
Diagnosis of subclinical mastitis in Santa Inês and Morada Nova sheep in southeastern Brazil.
Zafalon, Luiz Francisco; Santana, Raul Costa Mascarenhas; Pilon, Lucas Eduardo; Júnior, Guilherme Aparecido Fim
2016-06-01
The objective of this study was to evaluate different screening limits for the California mastitis test (CMT) and the somatic cell count (SCC) in previous diagnoses of subclinical mastitis in Santa Inês and Morada Nova ewes, which were reared under the same management conditions. Additionally, cutoff points were defined for SCC in accordance with the sensitivity and specificity of the test. A total of 907 mammary halves were subjected to CMT and SCC. The disease was confirmed by means of microbiological identification. Coagulase-negative staphylococci (CNS) were the microorganisms with highest occurrence. The CMT score of 1+ provided adequate sensitivity and specificity at all periods of lactation investigated. This score showed good agreement with SCC, >400,000 cells mL(-1). Higher cell counts favored higher diagnostic specificity. They can be used when producers have financial difficulties relating to treatment or culling of sheep with subclinical mastitis. However, producers should be warned about the risk of false-negative results in the flock.
Epi proColon® 2.0 CE: A Blood-Based Screening Test for Colorectal Cancer.
Lamb, Yvette N; Dhillon, Sohita
2017-04-01
Epi proColon ® 2.0 CE is a blood-based test designed to aid in the early detection of colorectal cancer. The test comprises a qualitative assay for the polymerase chain reaction (PCR) detection of methylated Septin9 DNA, the presence of which is associated with colorectal cancer: however, positive results should be verified by colonoscopy or sigmoidoscopy. Epi proColon ® 2.0 CE discriminated between patients with colorectal cancer and healthy controls with high clinical sensitivity and specificity in pivotal case-control studies. The sensitivity of the test did not appear to be affected by the tumour location or by patient age or gender. In addition, limited data suggest that Epi proColon ® 2.0 CE discriminated between patients with colorectal cancer and healthy controls with higher sensitivity and generally similar specificity to that of the faecal immunochemical test, and with higher sensitivity and specificity to that of the guaiac-based faecal occult blood test (statistical data not available). In an observational study, most patients who refused colonoscopy for screening accepted a non-invasive test option as an alternative, and preferred Epi proColon ® 2.0 CE over a stool-based test. Large prospective trials of Epi proColon ® 2.0 CE in a screening setting will be required to further elucidate the cost-effectiveness of the test. Nevertheless, currently available data suggests that Epi proColon ® 2.0 CE has the potential to be a sensitive and convenient screening option for patients refusing screening by colonoscopy.
Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M
2014-07-01
Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.
Caglar, Çagatay; Gul, Adem; Batur, Muhammed; Yasar, Tekin
2017-01-01
To compare the sensitivity and specificity of Moorfields regression analysis (MRA) and glaucoma probability score (GPS) between healthy and glaucomatous eyes with Heidelberg Retinal Tomograph 3 (HRT-3). The study included 120 eyes of 75 glaucoma patients and 138 eyes of 73 normal subjects, for a total of 258 eyes of 148 individuals. All measurements were performed with the HRT-3. Diagnostic test criteria (sensitivity, specificity, etc.) were used to evaluate how efficiently GPS and MRA algorithms in the HRT-3 discriminated between the glaucoma and control groups. The GPS showed 88 % sensitivity and 66 % specificity, whereas MRA had 71.5 % sensitivity and 82.5 % specificity. There was 71 % agreement between the final results of MRA and GPS in the glaucoma group. Excluding borderline patients from both analyses resulted in 91.6 % agreement. In the control group the level of agreement between MRA and GPS was 64 % including borderline patients and 84.1 % after excluding borderline patients. The accuracy rate is 92 % for MRA and 91 % for GPS in the glaucoma group excluding borderline patients. The difference was nor statistically different. In both cases, agreement was higher between MRA and GPS in the glaucoma group. We found that both sensitivity and specificity increased with disc size for MRA, while the sensitivity increased and specificity decreased with larger disc sizes for GPS. HRT is able to quantify and clearly reveal structural changes in the ONH and RNFL in glaucoma.
Evangelista, Mara Therese P; North, Jeffrey P
2015-11-01
Desmoplastic trichoepithelioma (DTE), morpheaform basal cell carcinoma (BCC) and microcystic adnexal carcinoma (MAC) are sclerosing adnexal neoplasms with overlapping histopathologic features. We compared cytokeratin 15, (CK15), T-cell death-associated gene 51 (TDAG51), cytokeratin 20 (CK20) and androgen receptor (AR) in differentiating these tumors and assessed their expression in BCC subtypes. Fifteen DTE, 15 infundibulocystic BCC, 18 micronodular BCC, 18 morpheaform BCC and 6 MAC were assessed for CK15, TDAG51, CK20 and AR expression. Quantitative CK15 staining was higher in DTE compared with BCC (p < 0.0001) and MAC (p = 0.02). Quantitative TDAG51 staining was higher in DTE than BCC (p < 0.0001). The CK20+AR- immunophenotype was 100% sensitive and specific in diagnosing DTE. The CK20-AR+ immunophenotype was 95.24% specific and 83.33% sensitive for BCC. The CK20-AR- immunophenotype was 83.33% sensitive and 90.91% specific for MAC. CK15, CK20 and AR were positive in 87, 53 and 67% of infundibulocystic BCC cases, respectively. Combination of CK20 and AR best differentiated these sclerosing adnexal neoplasms. Greater positivity for CK15 and TDAG51 generally favors benign lesions. Infundibulocystic BCC has higher CK20 and lower AR immunopositivity than other BCC variants and a high degree of CK15 and TDAG51 positivity. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Vitkova, O N; Kapustina, T P; Mikhailova, V V; Safonov, G A; Vlasova, N N; Belousova, R V
2015-01-01
The goal of this work was to demonstrate the results of the development of the enzyme-linked immunosorbent tests with chemiluminescence detection and colorimetric detection of specific viral antigens and antibodies for identifying the avian influenza and the Newcastle disease viruses: high sensitivity and specificity of the immuno- chemiluminescence assay, which are 10-50 times higher than those of the ELISA colorimetric method. The high effectiveness of the results and the automation of the process of laboratory testing (using a luminometer) allow these methods to be recommended for including in primary screening tests for these infectious diseases.
Koopman, Daniëlle; van Dalen, Jorn A; Arkies, Hester; Oostdijk, Ad H J; Francken, Anne Brecht; Bart, Jos; Slump, Cornelis H; Knollema, Siert; Jager, Pieter L
2018-01-16
We evaluated the diagnostic implications of a small-voxel reconstruction for lymph node characterization in breast cancer patients, using state-of-the-art FDG-PET/CT. We included 69 FDG-PET/CT scans from breast cancer patients. PET data were reconstructed using standard 4 × 4 × 4 mm 3 and small 2 × 2 × 2 mm 3 voxels. Two hundred thirty loco-regional lymph nodes were included, of which 209 nodes were visualised on PET/CT. All nodes were visually scored as benign or malignant, and SUV max and TB ratio (=SUV max /SUV background ) were measured. Final diagnosis was based on histological or imaging information. We determined the accuracy, sensitivity and specificity for both reconstruction methods and calculated optimal cut-off values to distinguish benign from malignant nodes. Sixty-one benign and 169 malignant lymph nodes were included. Visual evaluation accuracy was 73% (sensitivity 67%, specificity 89%) on standard-voxel images and 77% (sensitivity 78%, specificity 74%) on small-voxel images (p = 0.13). Across malignant nodes visualised on PET/CT, the small-voxel score was more often correct compared with the standard-voxel score (89 vs. 76%, p < 0.001). In benign nodes, the standard-voxel score was more often correct (89 vs. 74%, p = 0.04). Quantitative data were based on the 61 benign and 148 malignant lymph nodes visualised on PET/CT. SUVs and TB ratio were on average 3.0 and 1.6 times higher in malignant nodes compared to those in benign nodes (p < 0.001), on standard- and small-voxel PET images respectively. Small-voxel PET showed average increases in SUV max and TB ratio of typically 40% over standard-voxel PET. The optimal SUV max cut-off using standard-voxels was 1.8 (sensitivity 81%, specificity 95%, accuracy 85%) while for small-voxels, the optimal SUV max cut-off was 2.6 (sensitivity 78%, specificity 98%, accuracy 84%). Differences in accuracy were non-significant. Small-voxel PET/CT improves the sensitivity of visual lymph node characterization and provides a higher detection rate of malignant lymph nodes. However, small-voxel PET/CT also introduced more false-positive results in benign nodes. Across all nodes, differences in accuracy were non-significant. Quantitatively, small-voxel images require higher cut-off values. Readers have to adapt their reference standards.
New design concept of monopole antenna array for UHF 7T MRI.
Hong, Suk-Min; Park, Joshua Haekyun; Woo, Myung-Kyun; Kim, Young-Bo; Cho, Zang-Hee
2014-05-01
We have developed and evaluated a monopole antenna array that can increase sensitivity at the center of the brain for 7T MRI applications. We have developed a monopole antenna array that has half the length of a conventional dipole antenna with eight channels for brain imaging with a 7T MRI. The eight-channel monopole antenna array and conventional eight-channel transceiver surface coil array were evaluated and compared in terms of transmit properties, specific absorption ratio (SAR), and sensitivity. The sensitivity maps were generated by dividing the SNR map by the flip angle distribution. A single surface coil provides asymmetric sensitivity resulting in reduced sensitivity at the center of the brain. In contrast, a single monopole antenna provides higher sensitivity at the center of the brain. Moreover, the monopole antenna array provides uniform sensitivity over the entire brain, and the sensitivity gain was 1.5 times higher at the center of the brain compared with the surface coil array. The monopole antenna array is a promising candidate for MRI applications, especially for brain imaging in a 7T MRI because it provides increased sensitivity at the center of the brain. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Petruzzi, Massimo; Lucchese, Alberta; Nardi, Gianna Maria; Lauritano, Dorina; Favia, Gianfranco; Serpico, Rosario; Grassi, Felice Roberto
2014-07-01
The objective was to compare toluidine blue (TB) and autofluorescence (AF) for the detection of oral dysplasia and squamous cell carcinoma (OSCC) in clinically suspicious lesions according to conventional examination. Fifty-six clinically suspicious lesions were subjected to AF and TB examination. Data were compared using two different scenarios: in the first, mild dysplasia was considered as positive, while in the second, it was considered as negative. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), accuracy, and concordance were calculated. AF sensitivity and specificity were 70.0 and 57.7%, respectively, while TB showed a sensitivity of 80% and a specificity of 61.5%. The sensitivity increased in the second scenario in both AF (76.5%) and TB (88.2%). The specificity decreased in AF and TB, showing the same value (51.3%). PPV was higher in TB than in AF (70.6 versus 65.6%) and similarly for NPV (72.7 versus 62.5%). In the second scenario, TB PPV was 44.1% and NPV was 90.9% AF PPV was 40.6% and NPV was 83.3%. TB showed greater accuracy than AF in the first scenario (62.5 versus 58.9%). AF and TB are both sensitive but not specific in OSCC and dysplasia diagnosis.
Salotra, P; Sreenivas, G; Beena, K R; Mukherjee, A; Ramesh, V
2003-01-01
Aims: To evaluate the sensitivity and specificity of serological, immunohistochemical, and molecular methods in the diagnosis of post kala-azar dermal leishmaniasis (PKDL). Methods: Twenty five patients with confirmed PKDL and 25 controls were included in the study. G2D10, a monoclonal antibody against Leishmania, was used for the immunohistochemical (IHC) staining of lesion sections to visualise anti-Leishmania donovani antibodies. The diagnostic usefulness of IHC was compared with enzyme linked immunosorbent assay (ELISA) with a recombinant (rk39) antigen, and a species specific polymerase chain reaction (PCR) assay, amplifying a kinetoplast minicircle DNA sequence. Results: IHC detected 22 of 25 PKDL cases, giving a sensitivity of 88%. The diagnostic sensitivity of both the ELISA and PCR tests was higher (96%). All of the 25 controls examined were negative in PCR, indicating 100% specificity of the test, whereas ELISA showed 96% specificity. Conclusions: IHC with G2D10 significantly enhances the sensitivity of detection of PKDL over routine haematoxylin and eosin staining. ELISA with a recombinant antigen is an economical and practical assay. PCR is the most sensitive and specific diagnostic method for PKDL. The tests described would facilitate the recognition of patients with PKDL, enabling timely treatment, which would contribute greatly to the control of kala-azar. PMID:14600129
Calvo Sagardoy, Rosa; Gallego Morales, Luis T; Kassem García, Soledad; Codesal Julián, Rosana; Blanco Fernández, Ascensión; Solórzano Ostolaza, Gloria; Morales Martínez, Carmen
2014-11-04
To analyse the presence of heightened sensory sensitivity in patients with anorexia nervosa, which seems similar but not identical to that described in patients with unexplained somatic symptoms or body dysmorphic disorder. We developed a sensory sensitivity scale in eating disorders (SASTCA), which measures the intensity of the response to specific somatosensory stimuli. The scale was completed by 48 patients with anorexia and a control group of 31 participants matched in age, sex and social and educational level. The results were compared with those obtained with the Barsky Somatosensory Amplification Scale (SSAS). The reliability (Cronbach's/alpha, 0.946; Guttman/ split-half, 0.936) and validity (ROC, 0.933) of the SASTCA scale are indicative of its high sensitivity and specificity. The anorexia group had a significantly higher mean score on the SASTCA scale than the control group (p<.001). Similarly, the patients with anorexia had a significantly higher mean value on the SSAS than the participants in the control group (p<.01), although the difference was less extreme. The 2 scales correlated positively (r=.634). These preliminary results suggest the presence in Anorexia of heightened sensory sensitivity which differs from the sensitivity of the control group. This sensitivity has a significant relationship with that described in patients with somatic complaints about health (SSD) or appearance (BDD). Could this heightened sensory sensitivity help us to explain the process of forming the distorted body self-concept (I'm fat, sick, ugly) in all these patients? Once its presence has been confirmed in other patients with anorexia, their relatives and other patients with somatic disorders this heightened sensitivity could constitute the somatic endophenotype of anorexia? Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Meisal, Roger; Rounge, Trine Ballestad; Christiansen, Irene Kraus; Eieland, Alexander Kirkeby; Worren, Merete Molton; Molden, Tor Faksvaag; Kommedal, Øyvind; Hovig, Eivind; Leegaard, Truls Michael
2017-01-01
Sensitive and specific genotyping of human papillomaviruses (HPVs) is important for population-based surveillance of carcinogenic HPV types and for monitoring vaccine effectiveness. Here we compare HPV genotyping by Next Generation Sequencing (NGS) to an established DNA hybridization method. In DNA isolated from urine, the overall analytical sensitivity of NGS was found to be 22% higher than that of hybridization. NGS was also found to be the most specific method and expanded the detection repertoire beyond the 37 types of the DNA hybridization assay. Furthermore, NGS provided an increased resolution by identifying genetic variants of individual HPV types. The same Modified General Primers (MGP)-amplicon was used in both methods. The NGS method is described in detail to facilitate implementation in the clinical microbiology laboratory and includes suggestions for new standards for detection and calling of types and variants with improved resolution. PMID:28045981
Meisal, Roger; Rounge, Trine Ballestad; Christiansen, Irene Kraus; Eieland, Alexander Kirkeby; Worren, Merete Molton; Molden, Tor Faksvaag; Kommedal, Øyvind; Hovig, Eivind; Leegaard, Truls Michael; Ambur, Ole Herman
2017-01-01
Sensitive and specific genotyping of human papillomaviruses (HPVs) is important for population-based surveillance of carcinogenic HPV types and for monitoring vaccine effectiveness. Here we compare HPV genotyping by Next Generation Sequencing (NGS) to an established DNA hybridization method. In DNA isolated from urine, the overall analytical sensitivity of NGS was found to be 22% higher than that of hybridization. NGS was also found to be the most specific method and expanded the detection repertoire beyond the 37 types of the DNA hybridization assay. Furthermore, NGS provided an increased resolution by identifying genetic variants of individual HPV types. The same Modified General Primers (MGP)-amplicon was used in both methods. The NGS method is described in detail to facilitate implementation in the clinical microbiology laboratory and includes suggestions for new standards for detection and calling of types and variants with improved resolution.
Choe, Young June; Hu, Jae Kyung; Song, Kyung Min; Cho, Heeyeon; Yoon, Hee Sook; Kim, Seung Tae; Lee, Han Jung; Kim, Kisoon; Bae, Geun-Ryang; Lee, Jong-Koo
2012-01-01
In this study, we have described the clinical characteristics of vaccine-modified measles to assess the performance of an expanded case definition in a school outbreak that occurred in 2010. The sensitivity, specificity, and the positive and negative predictive values were evaluated. Among 74 cases of vaccine-modified measles, 47 (64%) met the original case definition. Fever and rash were observed in 73% (54/74); fever was the most common (96%, 71/74) presenting symptom, and rash was noted in 77% (57/74) of the cases. The original case definition showed an overall sensitivity of 63.5% and a specificity of 100.0%. The expanded case definition combining fever and rash showed a higher sensitivity (72.9%) but a lower specificity (88.2%) than the original. The presence of fever and one or more of cough, coryza, or conjunctivitis scored the highest sensitivity among the combinations of signs and symptoms (77.0%), but scored the lowest specificity (52.9%). The expanded case definition was sensitive in identifying suspected cases of vaccine-modified measles. We suggest using this expanded definition for outbreak investigation in a closed community, and consider further discussions on expanding the case definition of measles for routine surveillance in South Korea.
Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.
Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E
2017-05-01
To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.
Sensitivity and specificity of presumptive tests for blood, saliva and semen.
Vennemann, Marielle; Scott, Georgina; Curran, Lynn; Bittner, Felix; Tobe, Shanan S
2014-03-01
Despite their wide use, the limits of presumptive tests can be poorly understood. The aim of this study was to investigate the specificity and sensitivity of conventional, as well as innovative, presumptive tests for blood, semen and saliva. We investigated Kastle-Meyer (KM) and leucomalachite green (LMG) tests for blood with regard to their sensitivity and specificity in the presence of oxidizing (hypochlorite) and anti-oxidizing (ascorbic acid) agents. The suitability and specificity of the red starch paper (RSP) test for saliva was assessed. Finally, the inhibitory effect of detergent on the acid phosphatase (AP) test for semen was investigated along with possible cross reactions to tea stains. Our results confirm previous findings of higher sensitivity and specificity of the KM test compared to LMG test for blood. Contrary to previous studies, no statistically significant difference was observed in the sensitivity of the tests between dry and wet stains. The novel RSP test was found to successfully detect saliva. We demonstrated that acid phosphatase (AP) testing for semen is possible on used RSP. A common multipurpose detergent had an inhibitory effect on AP tests. False positive results were obtained from tea stains. Testing different sorts of tea (black, green and herbal teas) revealed that only Camellia varieties produce positive result with the AP test, due to AP being present in the plants. From our results we conclude that specific knowledge of each test, including substances that may affect the test outcome, is imperative to ensure correct interpretation of presumptive test results.
Zijenah, Lynn Sodai; Kadzirange, Gerard; Bandason, Tsitsi; Chipiti, Maria Mary; Gwambiwa, Bevel; Makoga, Forget; Chungu, Pauline; Kaguru, Philip; Dheda, Keertan
2016-01-22
In Zimbabwe, sputum smear microscopy (SSM) is the routinely used TB diagnostic tool in hospitalised HIV-infected patients. However, SSM has poor sensitivity in HIV-infected patients. We compared performance of urine lipoarabinomannan strip test (LAM) and SSM among hospitalized HIV-infected patients with suspected TB. Hospitalized HIV-infected patients with suspected TB were randomized to LAM plus SSM or SSM alone groups as part of a larger multi-country parent study. Here we present a comparison of LAM versus SSM performance from the Zimbabwe study site. LAM analyses (grade 2 cut-off) were conducted using (i) a microbiological reference standard (MRS; culture positivity for M.tb and designated definite TB) and (ii) a composite reference standard (CRS; definite TB plus probable TB i.e. patients with clinical TB excluded from the culture negative group). CRS constituted the primary analysis. 82/457 (18%) of the patients randomized to the LAM group were M.tuberculosis culture positive. Using CRS, sensitivity (%, 95% CI) of LAM was significantly higher than SSM [49.2 (42.1-56.4) versus 29.4(23.2-36.3); p < 0.001]. Specificity and PPV were 98.1%, and 95.8%, respectively. By contrast, using MRS, LAM sensitivity was similar to SSM and specificity was significantly lower, however, the combined sensitivity of LAM and SSM was significantly higher than that of SSM alone, p = 0.009. Using CRS, LAM sensitivity (%, CI) was CD4 count dependent [60.6(50.7-69.8) at ≤50 cells/μL; 40.0(22.7-59.4) at 51-100 cells/μL, and 32.8(21.0-46.3) at >100 cells/μL. The combined sensitivity of LAM and SSM was higher than SSM alone being highest at CD4 counts <50 cells/μL [67.6(57.9-76.3); p = <0.001]. Specificity of LAM or SSM alone, or of combined LAM and SSM was >97% in all the 3 CD4 strata. Among hospitalized HIV-infected patients with suspected TB, the sensitivity of LAM is significantly higher than that of SSM, especially at low CD4 counts. LAM and SSM are complimentary tests for diagnosis of TB in HIV-infected patients. We recommend a combination of LAM and SSM for TB diagnosis in HIV-infected patients with low CD4 counts in HIV/TB co-endemic countries, where alternative methods are unavailable.
[External respiration parameters in workers engaged in synthetic detergents production].
Makhon'ko, M N; Trubetskov, A D
2005-01-01
The study covers results of thorough clinical and functional examination of workers engaged into contemporary chemical production. The authors studied effects caused in immunity parameters, respiratory organs and skin by sensitizing and irritating chemicals. Findings are that the most significant changes in external respiration parameters and high predisposition to respiratory diseases are associated with specific sensitizing to industrial allergen and with higher IgE levels.
Canetta, Elisabetta; Riches, Andrew; Borger, Eva; Herrington, Simon; Dholakia, Kishan; Adya, Ashok K
2014-05-01
Atomic force microscopy (AFM) and modulated Raman spectroscopy (MRS) were used to discriminate between living normal human urothelial cells (SV-HUC-1) and bladder tumour cells (MGH-U1) with high specificity and sensitivity. MGH-U1 cells were 1.5-fold smaller, 1.7-fold thicker and 1.4-fold rougher than normal SV-HUC-1 cells. The adhesion energy was 2.6-fold higher in the MGH-U1 cells compared to normal SV-HUC-1 cells, which possibly indicates that bladder tumour cells are more deformable than normal cells. The elastic modulus of MGH-U1 cells was 12-fold lower than SV-HUC-1 cells, suggesting a higher elasticity of the bladder cancer cell membranes. The biochemical fingerprints of cancer cells displayed a higher DNA and lipid content, probably due to an increase in the nuclear to cytoplasm ratio. Normal cells were characterized by higher protein contents. AFM studies revealed a decrease in the lateral dimensions and an increase in thickness of cancer cells compared to normal cells; these studies authenticate the observations from MRS. Nanostructural, nanomechanical and biochemical profiles of bladder cells provide qualitative and quantitative markers to differentiate between normal and cancerous cells at the single cellular level. AFM and MRS allow discrimination between adhesion energy, elasticity and Raman spectra of SV-HUC-1 and MGH-U1 cells with high specificity (83, 98 and 95%) and sensitivity (97, 93 and 98%). Such single-cell-level studies could have a pivotal impact on the development of AFM-Raman combined methodologies for cancer profiling and screening with translational significance. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Liang, Su-Ying; Phillips, Kathryn A.; Wang, Grace; Keohane, Carol; Armstrong, Joanne; Morris, William M.; Haas, Jennifer S.
2012-01-01
Background Administrative claims and medical records are important data sources to examine healthcare utilization and outcomes. Little is known about identifying personalized medicine technologies in these sources. Objectives To describe agreement, sensitivity, and specificity of administrative claims compared to medical records for two pairs of targeted tests and treatments for breast cancer. Research Design Retrospective analysis of medical records linked to administrative claims from a large health plan. We examined whether agreement varied by factors that facilitate tracking in claims (coding and cost) and that enhance medical record completeness (records from multiple providers). Subjects Women (35 – 65 years) with incident breast cancer diagnosed in 2006–2007 (n=775). Measures Use of human epidermal growth factor receptor 2 (HER2) and gene expression profiling (GEP) testing, trastuzumab and adjuvant chemotherapy in claims and medical records. Results Agreement between claims and records was substantial for GEP, trastuzumab, and chemotherapy, and lowest for HER2 tests. GEP, an expensive test with unique billing codes, had higher agreement (91.6% vs. 75.2%), sensitivity (94.9% vs. 76.7%), and specificity (90.1% vs. 29.2%) than HER2, a test without unique billing codes. Trastuzumab, a treatment with unique billing codes, had slightly higher agreement (95.1% vs. 90%) and sensitivity (98.1% vs. 87.9%) than adjuvant chemotherapy. Conclusions Higher agreement and specificity were associated with services that had unique billing codes and high cost. Administrative claims may be sufficient for examining services with unique billing codes. Medical records provide better data for identifying tests lacking specific codes and for research requiring detailed clinical information. PMID:21422962
Salivary hexosaminidase in smoking alcoholics with bad periodontal and dental states.
Waszkiewicz, Napoleon; Chojnowska, Sylwia; Zalewska, Anna; Zwierz, Krzysztof; Szulc, Agata; Szajda, Sławomir Dariusz
2013-04-01
A sensitive alcohol marker, β-hexosaminidase (HEX), in the saliva of alcoholics, is investigated for the first time. The activity, specific-activity and output of total HEX and its isoenzymes HEX A and HEX B were measured in the saliva of healthy controls (C), alcohol-dependent non-smokers (ANS), and alcohol-dependent smokers (AS). We observed a significantly increased activity/specific-activity and output of HEX A in the ANS and AS groups, due to the inflammatory state of the oral-cavity/salivary-glands. Significantly increased activity of HEX A contributed to an increase in the salivary activity of the total HEX in the ANS group. A significant decrease in the activity/specific-activity of HEX B in AS seemed to be due to HEX B inactivation by cigarette smoke. We noticed a tendency for deteriorated dental state (lower decayed-missing-filled-teeth index - DMFT), worse periodontal state (higher gingival index - GI and papilla-bleeding index - PBI) in AS, and worse periodontal state (higher GI) in ANS, as compared to the controls. We found no differences in the salivary protein concentrations between all groups and decreased salivary flow in both alcoholic groups as compared to the controls. In alcoholics, the area under the curve (AUC) for HEX A activity/specific-activity was significantly greater than for HEX and HEX B. The salivary HEX A activity/specific-activity had good/excellent sensitivity and specificity in smoking and non-smoking alcoholics, whereas salivary HEX and HEX B had poor/fair sensitivity and specificity. Salivary HEX A may be helpful in the diagnosis of chronic alcohol intoxication, even in smokers. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Ganas, V; Kalaitzis, C; Sountoulides, P; Giannakopoulos, S; Touloupidis, S
2012-12-01
The aim of the study was to evaluate the predictive values of two novel urinary markers for bladder cancer: survivin and soluble-Fas (s-Fas). The study included 84 individuals divided in two groups. The first group contained 47 patients, who underwent transurethral bladder tumor resection and the second, control, group 20 patients with non-malignant conditions, who underwent cystoscopy and 17 health volunteers. Fresh, second morning voided urine was collected for measurement of s-Fas, survivin, BTA and for cytology. Sensitivity, specificity, positive and negative predictive values and accuracy were calculated. Bladder tumor patients had significantly higher survivin urine levels in comparison to the controls. Survivin correlated also with the tumor stage. Combination of survivin with BTA had a sensitivity of 86.4% but still lower than that of cystoscopy (97.8%). Only the specificity of the combination between survivin and BTA was higher than that of cystoscopy (86.4% and 75.6%, respectively). Survivin was a better marker for tumor detection than s-Fas and was better enough to discriminate cancer stage. Combination of survivin and BTA had a specificity of 86.4% to exclude bladder malignancy and the combination of s-Fas with survivin and BTA had a sensitivity of 93.6% to detect bladder cancer.
Xu, Zifeng; Zhang, Jianhai; Xia, Yunfei; Deng, Xiaoming
2014-01-01
To observe the change of PVI after thoracic epidural block on the basis of general anesthesia. In 26 patients undergoing elective upper abdominal operations, changes of SVI, PVI, SVV, PPV and CVP were monitored immediately before and 10 minutes after T8-9 thoracic epidural anesthesia on the basis of general anesthesia. The definition was that patients with ΔSVI greater than 10% belonged to response group to epidural block. Before epidural block, the PVI, SVV and PPV baseline values in patients of response group were significantly higher than those in patients of non-response group. PVI, SVV and PPV after epidural block were significantly higher than immediately before epidural block (P < 0.001). PVI, SVV and PPV baseline values immediately before epidural block were positively correlated with ΔSVI; the correlation coefficients were 0.70, 0.71 and 0.63, respectively, P ≤ 0.001. The optimal critical values for PVI, SVV and PPV to predict response to T8-9 gap epidural block under general anesthesia were 16% (sensitivity 80%, specificity 92%), 13% (sensitivity 90%, specificity 62%) and 12% (sensitivity 90%, specificity 77%), respectively. PVI can be used as a noninvasive indictor to monitor volume change after thoracic epidural block on the basis of general anesthesia.
Toluidine blue aids in detection of dysplasia and carcinoma in suspicious oral lesions.
Chainani-Wu, N; Madden, E; Cox, D; Sroussi, H; Epstein, J; Silverman, S
2015-10-01
Accurate clinical identification of 'higher-risk' oral premalignant lesions or 'higher-risk' areas within lesions is important. Assessment methods that predict their presence have great utility. A cross-sectional, observational study enrolled a consecutive sample of consenting patients diagnosed with oral leukoplakia, erythroleukoplakia, or erythroplakia. Medical history, visual oral examination, ViziLite(®) examination, toluidine blue staining (TBlue(®) ), and finally a biopsy were completed in a single clinic visit. Seventy-seven of 100 examined lesions in 43 patients were biopsied. Sensitivity, specificity, and positive and negative predictive values were computed for visual examination, ViziLite(®) , and TBlue(®) using biopsy results as the gold standard. The sensitivity of TBlue(®) in detecting high-risk lesions (carcinoma in situ or carcinoma) was 94 (71-100, P < 0.0003) and specificity 45 (32-58, P < 0.53), while for carcinoma, sensitivity was 100 (54-100, P < 0.032) and specificity 39 (28-52, P < 0.097). The results of ViziLite(®) testing either by itself or in combination with the information from toluidine blue testing revealed low sensitivity for the detection of high-risk lesions. Clinical examination of leukoplakia, erythroplakia, or erythroleukoplakia lesions combined with toluidine blue staining may aid in the identification of severe dysplasia (carcinoma in situ) or carcinoma. This may help in determining whether, when, and where (the site within a lesion) a biopsy should be taken. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
[Health economics analysis of specific immunotherapy in allergic rhinitis accompanied with asthma].
Chen, Jianjun; Xiang, Jisheng; Wang, Yanjun; Shi, Qiumei; Tan, Huifang; Kong, Weijia
2013-09-01
To investigate the cost-effectiveness of standardized specific immunotherapy (SIT) for allergic rhinitis patients accompanied with asthma (ARAS) in China. Forty ARAS patients sensitized with house dust mite (HDM) were administered with SIT (SIT group) or merely medicine treatment (control group). Alutard dermatophagoides pteronyssinus vaccine from ALK company was used for immunotherapy. The usage of symptom control medicine was according to the ARIA and GINA guideline. Cost-effectiveness ratio (CER) and Incremental cost-effectiveness ratio(ICER) analysis was conducted. The effectiveness was measured in terms of symptom scores, quality of life, objective improvement of rhinitis and asthma. Sensitive analysis was conducted to verify the stability of the results. The cost of SIT group for 1 year (6578 yuan) was higher than that of control group (1733.3 yuan), while the cost-effectiveness ratio and incremental cost-effectiveness ratio of SIT group were significant better than that of control group in all items. CER was 1686.7 yuan in SIT group compared with 3466.6 yuan in control group for nasal symptom scores, 4698.6 yuan in SIT group compared with 5777.8 yuan in control group for asthma symptom scores, 3462.1 yuan in SIT group compared with 8666.7 yuan in control group. The sensitive analysis of the price 10 percent higher or lower showed the same results. The cost-effectiveness of specific immunotherapy (SIT) for mite sensitized ARAS patients was better than that of merely medicine treatment.
Hermann, Laura L; Thaisomboonsuk, Butsaya; Poolpanichupatam, Yongyuth; Jarman, Richard G; Kalayanarooj, Siripen; Nisalak, Ananda; Yoon, In-Kyu; Fernandez, Stefan
2014-10-01
Currently, no dengue NS1 detection kit has regulatory approval for the diagnosis of acute dengue fever. Here we report the sensitivity and specificity of the InBios DEN Detect NS1 ELISA using a panel of well characterized human acute fever serum specimens. The InBios DENV Detect NS1 ELISA was tested using a panel composed of 334 serum specimens collected from acute febrile patients seeking care in a Bangkok hospital in 2010 and 2011. Of these patients, 314 were found to have acute dengue by either RT-PCR and/or anti-dengue IgM/IgG ELISA. Alongside the InBios NS1 ELISA kit, we compared the performance characteristics of the BioRad Platelia NS1 antigen kit. The InBios NS1 ELISA Ag kit had a higher overall sensitivity (86% vs 72.8%) but equal specificity (100%) compared to the BioRad Platelia kit. The serological status of the patient significantly influenced the outcome. In primary infections, the InBios NS1 kit demonstrated a higher sensitivity (98.8%) than in secondary infections (83.5%). We found significant variation in the sensitivity of the InBios NS1 ELISA kit depending on the serotype of the dengue virus and also found decreasing sensitivity the longer after the onset of illness, showing 100% sensitivity early during illness, but dropping below 50% by Day 7. The InBios NS1 ELISA kit demonstrated high accuracy when compared to the initial clinical diagnosis with greater than 85% agreement when patients were clinically diagnosed with dengue illness. Results presented here suggest the accurate detection of circulating dengue NS1 by the InBios DENV Detect NS1 ELISA can provide clinicians with a useful tool for diagnosis of early dengue infections.
Zhou, Ji-hong; Liu, Guang-nan; Huang, Si-ming; Zhong, Xiao-ning; Su, Hong; Zhou, Yi
2011-04-01
To detect the protein markers in serum and bronchoalveolar lavage fluid (BALF) of the patients with lung cancer by surface-enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF-MS) technology, and to explore if they can be used as markers for the diagnosis of lung cancer. SELDI-TOF-MS technology and protein chips weak cation exchange (WCX-2 chip) were used to detect the protein mass spectrum in serum and BALF of 35 patients with lung cancer and 18 cases of benign pulmonary diseases. The different protein markers were analyzed by Biomarker Pattern Software and the initial diagnosis models were set up. The diagnosis models were verified further by blind screen to confirm the efficacy of diagnosis. Five protein peaks in the sera of the patients with lung cancer were significantly higher (P < 0.05). The protein peak with a mass/charge ratio (M/Z) of 5639 was selected to establish the classification tree model. The sensitivity of diagnosis was 80% (28/35) and the specificity was 78% (14/18). The results verified by blind screen showed a sensitivity of 85% (17/20), a specificity of 90% (9/10), a crude accuracy (CA) of 87% (26/30) and Youden's index (γ) of 0.7. Eight protein peaks in the BALF of the patients with lung cancer were significantly higher (P < 0.05). The different protein peaks with M/Z of 7976 and 11 809 respectively were selected to establish the classification tree model. The sensitivity of diagnosis was 86% (30/35) and the specificity was 72% (13/18). The results verified by blind screen showed a sensitivity of 90% (18/20), a specificity of 90% (9/10), a CA of 90% (27/30) and γ of 0.8. There was a complementary role in combination of differential proteins in serum and BALF and the sensitivity, specificity and accuracy of diagnosis for lung cancer were 100% by parallel test. The SELDI-TOF-MS technology can screen out the differential protein markers in serum and BALF of the patients with lung cancer, which show high sensitivity and specificity as tumor markers. The differential proteins in the BALF may be more promising for clinical application.
Lubell, Yoel; Blacksell, Stuart D; Dunachie, Susanna; Tanganuchitcharnchai, Ampai; Althaus, Thomas; Watthanaworawit, Wanitda; Paris, Daniel H; Mayxay, Mayfong; Peto, Thomas J; Dondorp, Arjen M; White, Nicholas J; Day, Nicholas P J; Nosten, François; Newton, Paul N; Turner, Paul
2015-11-11
Poor targeting of antimicrobial drugs contributes to the millions of deaths each year from malaria, pneumonia, and other tropical infectious diseases. While malaria rapid diagnostic tests have improved use of antimalarial drugs, there are no similar tests to guide the use of antibiotics in undifferentiated fevers. In this study we estimate the diagnostic accuracy of two well established biomarkers of bacterial infection, procalcitonin and C-reactive protein (CRP) in discriminating between common viral and bacterial infections in malaria endemic settings of Southeast Asia. Serum procalcitonin and CRP levels were measured in stored serum samples from febrile patients enrolled in three prospective studies conducted in Cambodia, Laos and, Thailand. Of the 1372 patients with a microbiologically confirmed diagnosis, 1105 had a single viral, bacterial or malarial infection. Procalcitonin and CRP levels were compared amongst these aetiological groups and their sensitivity and specificity in distinguishing bacterial infections and bacteraemias from viral infections were estimated using standard thresholds. Serum concentrations of both biomarkers were significantly higher in bacterial infections and malaria than in viral infections. The AUROC for CRP in discriminating between bacterial and viral infections was 0.83 (0.81-0.86) compared with 0.74 (0.71-0.77) for procalcitonin (p < 0.0001). This relative advantage was evident in all sites and when stratifying patients by age and admission status. For CRP at a threshold of 10 mg/L, the sensitivity of detecting bacterial infections was 95% with a specificity of 49%. At a threshold of 20 mg/L sensitivity was 86% with a specificity of 67%. For procalcitonin at a low threshold of 0.1 ng/mL the sensitivity was 90% with a specificity of 39%. At a higher threshold of 0.5 ng/ul sensitivity was 60% with a specificity of 76%. In samples from febrile patients with mono-infections from rural settings in Southeast Asia, CRP was a highly sensitive and moderately specific biomarker for discriminating between viral and bacterial infections. Use of a CRP rapid test in peripheral health settings could potentially be a simple and affordable measure to better identify patients in need of antibacterial treatment and part of a global strategy to combat the emergence of antibiotic resistance.
Isidori, Andrea M; Cantisani, Vito; Giannetta, Elisa; Diacinti, Daniele; David, Emanuele; Forte, Valerio; Elia, Daniela; De Vito, Corrado; Sbardella, Emilia; Gianfrilli, Daniele; Monteleone, Francesco; Pepe, Jessica; Minisola, Salvatore; Ascenti, Giorgio; D'Andrea, Vito; Catalano, Carlo; D'Ambrosio, Ferdinando
2017-08-01
To evaluate the accuracy of ultrasound elastography with Elastoscan TM Core Index in the differential diagnosis of parathyroid lesions from ectopic thyroid nodules and lymph nodes. Seventy nine patients with repeatedly high levels of circulating intact parathyroid hormone, normal vitamin D and renal function tests, with an ultrasound scan showing a neck lesion, sharply demarcated from the thyroid lobules, were consecutively enrolled. Ultrasound with and without Color Doppler and ultrasound elastography were performed before histological examination. All ultrasound features, vascularization and ultrasound elastography diagnostic performance were assessed using ROC curves. Histological examination confirmed 47 parathyroid lesions, 18 thyroid ectopic nodules and 14 reactive lymph nodes. In distinguishing parathyroid from thyroid nodules, shape had a 100 % sensitivity (95 % CI 92.4-100) and 50 % specificity (95 % CI 37.2-64.7), cleavage had a 85.1 % sensitivity (95 % CI 72.3-92.6) and 77.8 % specificity (95 % CI 65.1-88) while peripheral vascularization had a sensitivity of 91.5 (95 % CI 79.6-97.6) and specificity of 72.2 (95 % CI 46.5-90.3). An Elastoscan TM Core Indexof 1.28 was 46 % sensitive (95 % CI 33.4-58.7) and 77 % specific (95 % CI 66.2-89.1) in discriminating parathyroid lesions from thyroid nodules. An Elastoscan TM Core Index of 1.0 was 78 % sensitive (95 % CI 65.1-88) and 71 % specific (95 % CI 56-81.3) in discriminating parathyroid lesions from lymph nodes (p = 0.045). An Elastoscan TM Core Index greater than 2.58 had a 100 % sensitivity (95 % CI 43.8-100) and 95.4 % specificity (95 % CI 38.3-99.7) in discriminating malignant from benign parathyroid nodules. Elastoscan TM Core Index was significantly higher in thyroid nodules than in reactive lymph nodes (1.18 ± 0.62, p = 0.008). The ultrasound features of cleavage and peripheral vascularization help to differentiate parathyroid from thyroid nodules. Elastoscan TM Core Index can improve ultrasound discrimination of parathyroid lesions from lymph nodes. The Elastoscan TM Core Index is significantly higher in malignant than in benign parathyroid lesions.
Sensitivity and specificity of the 3-item memory test in the assessment of post traumatic amnesia.
Andriessen, Teuntje M J C; de Jong, Ben; Jacobs, Bram; van der Werf, Sieberen P; Vos, Pieter E
2009-04-01
To investigate how the type of stimulus (pictures or words) and the method of reproduction (free recall or recognition after a short or a long delay) affect the sensitivity and specificity of a 3-item memory test in the assessment of post traumatic amnesia (PTA). Daily testing was performed in 64 consecutively admitted traumatic brain injured patients, 22 orthopedically injured patients and 26 healthy controls until criteria for resolution of PTA were reached. Subjects were randomly assigned to a test with visual or verbal stimuli. Short delay reproduction was tested after an interval of 3-5 minutes, long delay reproduction was tested after 24 hours. Sensitivity and specificity were calculated over the first 4 test days. The 3-word test showed higher sensitivity than the 3-picture test, while specificity of the two tests was equally high. Free recall was a more effortful task than recognition for both patients and controls. In patients, a longer delay between registration and recall resulted in a significant decrease in the number of items reproduced. Presence of PTA is best assessed with a memory test that incorporates the free recall of words after a long delay.
Angkasekwinai, Nasikarn; Atkins, Erin H.; Romero, Sofia; Grieco, John; Chao, Chien Chung; Ching, Wei Mei
2014-01-01
Reliable laboratory testing is of great importance to detect Bartonella bacilliformis infection. We evaluated the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) using recombinant protein Pap31 (rPap31) for the detection of antibodies against B. bacilliformis as compared with immunofluorescent assay (IFA). Of the 302 sera collected between 1997 and 2000 among an at-risk Peruvian population, 103 and 34 samples tested positive for IFA-immunoglobulin G (IgG) and IFA-IgM, respectively. By using Youden's index, the cutoff values of ELISA-IgG at 0.915 gave a sensitivity of 84.5% and specificity of 94%. The cutoff values of ELISA-IgM at 0.634 gave a sensitivity of 88.2% and specificity of 85.1%. Using latent class analysis, estimates of sensitivity and specificity of almost all the assays were slightly higher than those of a conventional method of calculation. The test is proved beneficial for discriminating between infected and non-infected individuals with the advantage of low-cost and high-throughput capability. PMID:24515944
The Danish test battery for auditory processing disorder evaluated with patient and control data.
Raben Pedersen, Ellen
2018-06-10
This study evaluates the Danish test battery for auditory processing disorder (APD). The battery consists of four behavioural tests, two speech and two non-speech stimuli tests. The evaluation includes determination of: (1) new cut-off values (pass-fail criteria), (2) the sensitivity and the specificity of the entire test battery and (3) the failure rate of different test combinations. For each test in the battery, cut-off values were determined using the weighted Youden index. Applying the newly derived cut-off values, the distribution of failing specific test combinations was determined. A group of 112 children diagnosed with APD (57 boys, 55 girls, aged 6-16 years) and a control group containing 158 children without auditory problems (75 boys, 83 girls, aged 6-16 years). Cut-off values for different weights of the sensitivity and the specificity have been determined. Using the criterion that at least two tests have to be failed for APD to be suspected, the sensitivity and the specificity of the entire test battery were 95.3% and 91.6%, respectively. Some test combinations were found to have higher failure rates than others. Due to the high sensitivity and specificity the test battery has good predictive value in APD assessment.
[Primary cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María
2015-01-01
Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Tang, Liang; Feng, Shiqing; Gao, Ruixiao; Han, Chenfu; Sun, Xiaochen; Bao, Yucheng; Zhang, Wenlong
2017-12-01
The aim of the present study was to compare the efficacy of the commercial Xpert Mycobacterium tuberculosis/rifampin (MTB/RIF) test for evaluating different types of spinal tuberculosis (TB) tissue specimens. Pus, granulation tissue, and caseous necrotic tissue specimens from 223 patients who were diagnosed with spinal TB and who underwent curettage were collected for bacterial culture and the Xpert MTB/RIF assay to calculate the positive rate. Bacterial culture and phenotypic drug sensitivity testing (pDST) were adopted as the gold standards to calculate the sensitivity and specificity of the Xpert bacterial detection and drug resistance (DR) test. The positive rate (68.61% ± 7.35%) from the Xpert MTB/RIF assays of spinal TB patients' tissue specimens was higher compared with bacterial culture (44.39% ± 6.51%, Z = 5.1642, p < 0.01), and the positive rates from Xpert MTB/RIF assays on the three types of specimens were all higher than those of bacterial culture, with statistically significant results for pus and granulation tissue specimens. The positive rates for pus using the two bacteriological tests were higher than those for granulation tissue but were not statistically significant. However, the positive rates obtained from granulation tissue were statistically significantly higher than those obtained from caseous necrotic tissue. With bacterial culture and pDST as the gold standards, the sensitivity of Xpert MTB/RIF assays for MTB was 96.97%, while the sensitivity and specificity of the DR test also remained relatively high. For efficient and accurate diagnosis of spinal TB and DR and timely provision of effective treatment, multiple specimens, especially the pus of spinal TB patients, should be collected for Xpert MTB/RIF assays.
Kroghsbo, Stine; Bøgh, Katrine L; Rigby, Neil M; Mills, E N Clare; Rogers, Adrian; Madsen, Charlotte B
2011-01-01
It is not known why some foods sensitizing via the gastrointestinal tract are prevalent allergenic foods and others are not. Eating habits, processing, and the food matrix have been suggested to influence the allergenicity of a given food. Factors related to protein structure, such as stability to digestion, have also been suggested. 7S globulins from peanut, hazelnut, soy, and pea were studied to determine whether related proteins would induce a similar sensitization when removed from their 'normal' matrix. Brown Norway rats (soy tolerant or nontolerant) were immunized i.p. 3 times with 100 μg purified peanut, hazelnut, soy, or pea 7S without adjuvant. Sera were analyzed for specific antibodies by different ELISAs (IgG1, IgG2a, and IgE), inhibition ELISA, and rat basophilic leukemia cell assay. The 4 related 7S globulins induced a response with an almost identical level of specific antibodies, but peanut 7S induced IgE of higher avidity than hazelnut and pea 7S which, again, had a higher avidity than IgE induced by soy 7S. Soy tolerance reduced the functionality of IgE without influencing antibody titers. Although the 4 7S globulins are structurally related allergens, they induce antibodies with different antigen-binding characteristics. Peanut 7S induces IgE of a higher avidity than hazelnut and pea 7S which, again, has a higher avidity than IgE induced by soy 7S. We also show that soy tolerance influences the function of antibodies to peanut 7S. These findings may help explain how antibodies of different clinical significances can develop in different individuals sensitized to the same allergen. Copyright © 2011 S. Karger AG, Basel.
Optical diagnosis of cervical cancer by higher order spectra and boosting
NASA Astrophysics Data System (ADS)
Pratiher, Sawon; Mukhopadhyay, Sabyasachi; Barman, Ritwik; Pratiher, Souvik; Pradhan, Asima; Ghosh, Nirmalya; Panigrahi, Prasanta K.
2017-03-01
In this contribution, we report the application of higher order statistical moments using decision tree and ensemble based learning methodology for the development of diagnostic algorithms for optical diagnosis of cancer. The classification results were compared to those obtained with an independent feature extractors like linear discriminant analysis (LDA). The performance and efficacy of these methodology using higher order statistics as a classifier using boosting has higher specificity and sensitivity while being much faster as compared to other time-frequency domain based methods.
Urošević, Snežana; Collins, Paul; Muetzel, Ryan; Lim, Kelvin O; Luciana, Monica
2014-08-01
Adolescence is characterized by complex developmental processes that impact behavior, biology, and social functioning. Two such adolescence-specific processes are puberty and increases in reward sensitivity. Relations between these processes are poorly understood. The present study focused on examining unique effects of puberty, age, and sex on reward and threat sensitivities and volumes of subcortical brain structures relevant for reward/threat processing in a healthy sample of 9-18year-olds. Unlike age, pubertal status had a significant unique positive relationship with reward sensitivity. In addition, there was a trend for adolescent females to exhibit higher threat sensitivity with more advanced pubertal development and higher reward and threat sensitivity with older age. Similarly, there were significant puberty by sex interaction effects on striatal volumes, i.e., left nucleus accumbens and right pallidum. The present pattern of results suggests that pubertal development, independent of chronological age, is uniquely associated with reward hypersensitivity and with structural differences in striatal regions implicated in reward processing. Copyright © 2014 Elsevier Inc. All rights reserved.
Sjoding, Michael W; Schoenfeld, David A; Brown, Samuel M; Hough, Catherine L; Yealy, Donald M; Moss, Marc; Angus, Derek C; Iwashyna, Theodore J
2017-01-01
After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT's power to measure significant differences in these outcomes is poorly understood. Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. We derived a general formula and Stata code for calculating an RCT's power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress-like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT ( www.clinicaltrials.gov identifier NCT02509078). On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Examining instruments' power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities.
Schoenfeld, David A.; Brown, Samuel M.; Hough, Catherine L.; Yealy, Donald M.; Moss, Marc; Angus, Derek C.; Iwashyna, Theodore J.
2017-01-01
Rationale: After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT’s power to measure significant differences in these outcomes is poorly understood. Objectives: Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. Methods: We derived a general formula and Stata code for calculating an RCT’s power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress–like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT (www.clinicaltrials.gov identifier NCT02509078). Measurements and Main Results: On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Conclusions: Examining instruments’ power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities. PMID:27788018
Keller, Marla J.; Buckley, Niall; Katzen, Lauren L.; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C.; Einstein, Mark H.
2014-01-01
Background Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or pre-sex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Methods Healthy monogamous couples received Microlax®-type applicators filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert one dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen followed by UV then DSA and scored by two readers. Positive and negative controls were randomly included in applicator batches. Results Fifteen couples completed the study. Each female returned at least six applicators over a 30-day period. The sensitivity for insertion of post-sex applicators was higher for UV (97%) compared to DSA (90%) and the specificity was similar (≥96%). For pre-sex applicators, the sensitivity and specificity were higher for DSA (100%) compared to UV testing (87% sensitivity, 96% specificity). Among returned post-sex applicators, 95% tested positive by UV compared to 87% by DSA. Agreement between readers was significantly better on the pre-sex applicators for DSA than for UV and for post-sex readings agreement was less than half that for UV, although the results were not statistically significant. Conclusions Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex. PMID:24220355
Hassan, Mahmoud Fathy; Rund, Nancy Mohamed Ali; Salama, Ahmed Husseiny
2013-01-01
Background. To assess the ability of mid-trimester sFlt-1/PlGF ratio for prediction of preeclampsia in two different Arabic populations. Methods. This study measured levels of sFlt-1, PlGF, and sFlt-1/PlGF ratio at midtrimester in 83 patients who developed preeclampsia with contemporary 250 matched controls. Results. Women subsequently developed preeclampsia had significantly lower PlGF levels and higher sFlt-1 and sFlt-1/PlGF ratio levels than women with normal pregnancies (P < 0.0001 for all). Women who with preterm preeclampsia had significantly higher sFlt-1 and sFlt-1/PlGF ratio than term preeclamptic women (P = 0.01, 0.003, resp.). A cutoff value of 3198 pg/mL for sFlt-1 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 88%, 83.6%, and 84.7%, respectively, with odds ratio (OR) 37.2 [95% confidence interval (CI) 17.7-78.1]. PIGF at cutoff value of 138 pg/mL was able to predict preeclampsia with sensitivity, specificity, and accuracy of 85.5%, 77.2%, and 79.3%, respectively, with OR 20 [95% CI, 10.2-39.5]. The sFlt-1/PIGF ratio at cutoff value of 24.5 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 91.6%, 86.4%, and 87.7%, respectively with OR 67 [95% CI, 29.3-162.1]. Conclusion. Midtrimester sFlt-1/PlGF ratio displayed the highest sensitivity, specificity, accuracy, and OR for prediction of preeclampsia, demonstrating that it may stipulate more effective prediction of preeclampsia development than individual factor assay.
Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A
2016-06-01
Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Iwazawa, J; Ohue, S; Hashimoto, N; Mitani, T
2014-02-01
To compare the accuracy of computer software analysis using three different target-definition protocols to detect tumour feeder vessels for transarterial chemoembolization of hepatocellular carcinoma. C-arm computed tomography (CT) data were analysed for 81 tumours from 57 patients who had undergone chemoembolization using software-assisted detection of tumour feeders. Small, medium, and large-sized targets were manually defined for each tumour. The tumour feeder was verified when the target tumour was enhanced on selective C-arm CT of the investigated vessel during chemoembolization. The sensitivity, specificity, and accuracy of the three protocols were evaluated and compared. One hundred and eight feeder vessels supplying 81 lesions were detected. The sensitivity of the small, medium, and large target protocols was 79.8%, 91.7%, and 96.3%, respectively; specificity was 95%, 88%, and 50%, respectively; and accuracy was 87.5%, 89.9%, and 74%, respectively. The sensitivity was significantly higher for the medium (p = 0.003) and large (p < 0.001) target protocols than for the small target protocol. The specificity and accuracy were higher for the small (p < 0.001 and p < 0.001, respectively) and medium (p < 0.001 and p < 0.001, respectively) target protocols than for the large target protocol. The overall accuracy of software-assisted automated feeder analysis in transarterial chemoembolization for hepatocellular carcinoma is affected by the target definition size. A large target definition increases sensitivity and decreases specificity in detecting tumour feeders. A target size equivalent to the tumour size most accurately predicts tumour feeders. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Fujita, Takaaki; Sato, Atsushi; Tsuchiya, Kenji; Ohashi, Takuro; Yamane, Kazuhiro; Yamamoto, Yuichi; Iokawa, Kazuaki; Ohira, Yoko; Otsuki, Koji; Tozato, Fusae
2017-12-01
This study aimed to elucidate the relationship between grooming performance of stroke patients and various motor and cognitive functions and to examine the cognitive and physical functional standards required for grooming independence. We retrospectively analyzed the data of 96 hospitalized patients with first stroke in a rehabilitation hospital ward. Logistic regression analysis and receiver operating characteristic curves were used to investigate the related cognitive and motor functions with grooming performance and to calculate the cutoff values for independence and supervision levels in grooming. For analysis between the independent and supervision-dependent groups, the only item with an area under the curve (AUC) of .9 or higher was the Berg Balance Scale, and the calculated cutoff value was 41/40 (sensitivity, 83.6%; specificity, 87.8%). For analysis between the independent-supervision and dependent groups, the items with an AUC of .9 or higher were the Simple Test for Evaluating Hand Function (STEF) on the nonaffected side, Vitality Index (VI), and FIM ® cognition. The cutoff values were 68/67 for the STEF (sensitivity, 100%; specificity, 72.2%), 9/8 points for the VI (sensitivity, 92.3%; specificity, 88.9%), and 23/22 points for FIM ® cognition (sensitivity, 91.0%; specificity, 88.9%). Our results suggest that upper-extremity functions on the nonaffected side, motivation, and cognitive functions are particularly important to achieve the supervision level and that balance is important to reach the independence level. The effective improvement of grooming performance is possible by performing therapeutic or compensatory intervention on functions that have not achieved these cutoff values. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Pivetta, Emanuele; Goffi, Alberto; Lupia, Enrico; Tizzani, Maria; Porrino, Giulio; Ferreri, Enrico; Volpicelli, Giovanni; Balzaretti, Paolo; Banderali, Alessandra; Iacobucci, Antonello; Locatelli, Stefania; Casoli, Giovanna; Stone, Michael B; Maule, Milena M; Baldi, Ileana; Merletti, Franco; Cibinel, Gian Alfonso; Baron, Paolo; Battista, Stefania; Buonafede, Giuseppina; Busso, Valeria; Conterno, Andrea; Del Rizzo, Paola; Ferrera, Patrizia; Pecetto, Paolo Fascio; Moiraghi, Corrado; Morello, Fulvio; Steri, Fabio; Ciccone, Giovannino; Calasso, Cosimo; Caserta, Mimma A; Civita, Marina; Condo', Carmen; D'Alessandro, Vittorio; Del Colle, Sara; Ferrero, Stefania; Griot, Giulietta; Laurita, Emanuela; Lazzero, Alberto; Lo Curto, Francesca; Michelazzo, Marianna; Nicosia, Vincenza; Palmari, Nicola; Ricchiardi, Alberto; Rolfo, Andrea; Rostagno, Roberto; Bar, Fabrizio; Boero, Enrico; Frascisco, Mauro; Micossi, Ilaria; Mussa, Alessandro; Stefanone, Valerio; Agricola, Renzo; Cordero, Gabriele; Corradi, Federica; Runzo, Cristina; Soragna, Aldo; Sciullo, Daniela; Vercillo, Domenico; Allione, Attilio; Artana, Nicoletta; Corsini, Fabrizio; Dutto, Luca; Lauria, Giuseppe; Morgillo, Teresa; Tartaglino, Bruno; Bergandi, Daniela; Cassetta, Ilaria; Masera, Clotilde; Garrone, Mario; Ghiselli, Gianluca; Ausiello, Livia; Barutta, Letizia; Bernardi, Emanuele; Bono, Alessia; Forno, Daniela; Lamorte, Alessandro; Lison, Davide; Lorenzati, Bartolomeo; Maggio, Elena; Masi, Ilaria; Maggiorotto, Matteo; Novelli, Giulia; Panero, Francesco; Perotto, Massimo; Ravazzoli, Marco; Saglio, Elisa; Soardo, Flavia; Tizzani, Alessandra; Tizzani, Pietro; Tullio, Mattia; Ulla, Marco; Romagnoli, Elisa
2015-07-01
Lung ultrasonography (LUS) has emerged as a noninvasive tool for the differential diagnosis of pulmonary diseases. However, its use for the diagnosis of acute decompensated heart failure (ADHF) still raises some concerns. We tested the hypothesis that an integrated approach implementing LUS with clinical assessment would have higher diagnostic accuracy than a standard workup in differentiating ADHF from noncardiogenic dyspnea in the ED. We conducted a multicenter, prospective cohort study in seven Italian EDs. For patients presenting with acute dyspnea, the emergency physician was asked to categorize the diagnosis as ADHF or noncardiogenic dyspnea after (1) the initial clinical assessment and (2) after performing LUS ("LUS-implemented" diagnosis). All patients also underwent chest radiography. After discharge, the cause of each patient's dyspnea was determined by independent review of the entire medical record. The diagnostic accuracy of the different approaches was then compared. The study enrolled 1,005 patients. The LUS-implemented approach had a significantly higher accuracy (sensitivity, 97% [95% CI, 95%-98.3%]; specificity, 97.4% [95% CI, 95.7%-98.6%]) in differentiating ADHF from noncardiac causes of acute dyspnea than the initial clinical workup (sensitivity, 85.3% [95% CI, 81.8%-88.4%]; specificity, 90% [95% CI, 87.2%-92.4%]), chest radiography alone (sensitivity, 69.5% [95% CI, 65.1%-73.7%]; specificity, 82.1% [95% CI, 78.6%-85.2%]), and natriuretic peptides (sensitivity, 85% [95% CI, 80.3%-89%]; specificity, 61.7% [95% CI, 54.6%-68.3%]; n = 486). Net reclassification index of the LUS-implemented approach compared with standard workup was 19.1%. The implementation of LUS with the clinical evaluation may improve accuracy of ADHF diagnosis in patients presenting to the ED. Clinicaltrials.gov; No.: NCT01287429; URL: www.clinicaltrials.gov.
Pfluger, Thomas; Schmied, Christoph; Porn, Ute; Leinsinger, Gerda; Vollmar, Christian; Dresel, Stefan; Schmid, Irene; Hahn, Klaus
2003-10-01
The objectives of this study were to compare MRI and iodine-123 ((123)I) metaiodobenzylguanidine (MIBG) scintigraphy in the detection of neuroblastoma lesions in pediatric patients and to assess the additional value of combined imaging. Fifty MRI and 50 (123)I MIBG examinations (mean interval, 6.4 days) were analyzed retrospectively with regard to suspected or proven neuroblastoma lesions (n = 193) in 28 patients. MRI and MIBG scans were reviewed by two independent observers each. Separate and combined analyses of MRI and MIBG scintigraphy were compared with clinical and histologic findings. With regard to the diagnosis of neuroblastoma lesion, MIBG scintigraphy, MRI, and combined analysis showed a sensitivity of 69%, 86%, and 99% and a specificity of 85%, 77%, and 95%, respectively. On MRI, 15 false-positive findings were recorded: posttherapeutic reactive changes (n = 10), benign adrenal tumors (n = 3), and enlarged lymph nodes (n = 2). On MIBG scintigraphy, 10 false-positive findings occurred: ganglioneuromas (n = 2), benign liver tumors (n = 2), and physiologic uptake (n = 6). Thirteen neuroblastoma metastases and two residual masses under treatment with chemotherapy were judged to be false-negative findings on MRI. Two primary or residual neuroblastomas and one orbital metastasis were misinterpreted as Wilms' tumor, reactive changes after surgery, and rhabdomyosarcoma on MRI. Thirty-two bone metastases, six other neuroblastoma metastases, and one adrenal neuroblastoma showed no MIBG uptake. On combined imaging, one false-negative (bone metastasis) and three false-positive (two ganglioneuromas and one pheochromocytoma) findings remained. In the assessment of neuroblastoma lesions in pediatric patients, MRI showed a higher sensitivity and MIBG scintigraphy a higher specificity. However, integrated imaging showed an increase in both sensitivity and specificity.
Jiang, Lindi; Wang, Zhen; Dai, Xiaomin; Jin, Xuejuan
2011-04-01
To determine the value of clinical measures in diagnosis of adult-onset Still's disease (AOSD), and to identify the optimal set of proposed classification criteria, in a Chinese population. A total of 70 patients with AOSD and 140 non-AOSD inpatients with fever were retrospectively identified at Zhongshan Hospital, Shanghai, from January 2003 to December 2009. Clinical measures and 4 sets of diagnostic criteria (Yamaguchi, Calabro, Cush, and Reginato) were evaluated by sensitivity, specificity, positive/negative predictive value (PPV, NPV), and positive/negative likelihood ratio (PLR, NLR) for diagnosis of AOSD. In our series, higher sensitivity included hyperpyrexia (temperature ≥ 39°C, 94.29%), arthralgia (80.0%), polymorphonuclear neutrophils (PMN) ≥ 75% (84.29%), serum ferritin ≥ 2-fold the upper normal value (90.0%), negative antinuclear antibodies (85.29%), and rheumatoid factor (84.38%); while higher specificity included transient erythema (98.57%), sore throat (85.0%), leukocytes ≥ 15,000/mm(3) (87.86%), and PMN ≥ 85% (85.0%). Rash, arthralgia, and sore throat were found to have better sensitivity and specificity (PLR 3.29-4.86). Leukocytes ≥ 10,000/mm(3), PMN ≥ 80%, and serum ferritin ≥ 5-fold the upper normal limit were set as critical points. The Reginato criteria set had the highest specificity, 99.29%. The Yamaguchi set had the highest sensitivity, 78.57%, with a better accuracy of 87.14%. The Yamaguchi diagnostic criteria had better accuracy in Chinese patients. Indicators such as rash, arthralgia, sore throat, leukocytes ≥ 10,000/mm(3), PMN ≥ 80%, and serum ferritin ≥ 5-fold the upper normal limit were helpful for diagnosis of AOSD. We recommend using these indicators in combination instead of alone.
Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.
Iskandar, Livia; Braun, Kathryn L; Katz, Alan R
2015-04-01
Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.
Albuquerque, Andreia; Sheaff, Michael; Stirrup, Oliver; Cappello, Carmelina; Bowring, Julie; Cuming, Tamzin; de Masi, Anke; Rosenthal, Adam N; Nathan, Mayura
2018-04-05
Information on the performance of anal cytology in women who are high-risk for human papillomavirus-related lesions and the factors that might influence it are largely lacking. Evaluate the performance of anal cytology in women with lower anogenital tract neoplasia. retrospective study including all new referrals of women with a previous history of anogenital neoplasia, from January 2012 to July 2017, with concomitant anal cytology and high-resolution anoscopy with or without biopsies. 636 anal cytology samples and 323 biopsies were obtained from 278 women. Overall sensitivity and specificity of 'any abnormality' on anal cytology to predict 'any abnormality' in histology was 47% (95% CI 41-54%) and 84% (95% CI 73-91%), respectively. For detecting high-grade squamous intraepithelial lesions (HSIL)/cancer, sensitivity was 71% (95% CI 61-79%) and specificity was 73% (95% CI 66-79%). There was a poor concordance between cytological and histological grades (κ=0.147). Cytology had a higher sensitivity to predict HSIL/cancer in immunosuppressed vs. non-immunosuppressed patients (92% vs. 60%, P=0.002). The sensitivity for HSIL detection was higher when two or more quadrants were affected in comparison with only one (86% vs. 57%, P=0.006). A previous history of vulvar HSIL/cancer (OR 1.71, 1.08-2.73; P=0.023), immunosuppression (OR 1.88, 1.17-3.03; P=0.009) and concomitant genital HSIL/cancer (OR 2.51, 1.47-4.29; P=0.001) were risk factors for abnormal cytology. Patient characteristics can influence the performance of anal cytology in women. The sensitivity for detecting anal HSIL/cancer was higher in those immunosuppressed and with more extensive disease.
Evaluation of YB-1 levels in patients with endometriosis.
Ahrens, Thorben; Silveira, Cassia G T; Banz-Jansen, Constanze; Rody, Achim; Hornung, Daniela
2015-08-01
The objective of this study is the evaluation of serum YB-1 levels in the diagnosis of endometriosis. Serum samples of 12 patients with histologically confirmed endometriosis and of 10 control patients were collected. Western blot analysis was used to assess serum YB-1 levels. Groups were compared with Student's t-test or, if not normally distributed, with the Mann-Whitney test. Sensitivity and specificity for the potential diagnostic performance of serum YB-1 were assessed by receiver operating characteristic (ROC) curves. Serum YB-1 levels were significantly higher in patients with endometriosis (=0.004). The area under the curve was 0.867 (95% confidence interval 0.714-1.019) with sensitivity and specificity of 83.3% and 70% respectively. Serum YB-1 levels in patients with endometriosis are significantly higher compared to control patients and may be used as a potential diagnostic biomarker for endometriosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Multi-test cervical cancer diagnosis with missing data estimation
NASA Astrophysics Data System (ADS)
Xu, Tao; Huang, Xiaolei; Kim, Edward; Long, L. Rodney; Antani, Sameer
2015-03-01
Cervical cancer is a leading most common type of cancer for women worldwide. Existing screening programs for cervical cancer suffer from low sensitivity. Using images of the cervix (cervigrams) as an aid in detecting pre-cancerous changes to the cervix has good potential to improve sensitivity and help reduce the number of cervical cancer cases. In this paper, we present a method that utilizes multi-modality information extracted from multiple tests of a patient's visit to classify the patient visit to be either low-risk or high-risk. Our algorithm integrates image features and text features to make a diagnosis. We also present two strategies to estimate the missing values in text features: Image Classifier Supervised Mean Imputation (ICSMI) and Image Classifier Supervised Linear Interpolation (ICSLI). We evaluate our method on a large medical dataset and compare it with several alternative approaches. The results show that the proposed method with ICSLI strategy achieves the best result of 83.03% specificity and 76.36% sensitivity. When higher specificity is desired, our method can achieve 90% specificity with 62.12% sensitivity.
Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.
Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu
2017-09-01
The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Wagner, Ernst; Skoumal, M; Bayer, P M; Klaushofer, K
2009-09-01
The aim of this study was to determine the performance of antibodies against mutated citrullinated vimentin (anti-MCV) in comparison with antibodies to cyclic citrullinated peptides (anti-CCP) in patients with rheumatoid arthritis (RA). Serum levels of anti-MCV and anti-CCP were determined in 193 patients with RA and 332 controls, and sensitivity and specificity were calculated. In a separate analysis of 86 patients, the anti-MCV levels were compared to disease activity. Sensitivity of anti-MCV versus anti-CCP was 71.5 and 69.4%, specificity was 81.3 and 97.6%, respectively. The ROC curves showed higher specificity and an advantage of anti-CCP. In seronegative RA patients the sensitivity of anti-MCV was superior over anti-CCP. Anti-MCV positivities also occurred in systemic lupus erythematosus and Sjoegren's syndrome. In a subgroup of 86 RA patients we found a significant correlation between anti-MCV and disease activity. Anti-MCV appears to be an important marker for the diagnosis of RA, and correlates also with disease activity.
NASA Astrophysics Data System (ADS)
Dong, Shihao; Wen, Ping; Zhang, Qi; Li, Xinyu; Tan, Ken; Nieh, James
2017-03-01
In highly social bees, queen mandibular pheromone (QMP) is vital for colony life. Both Apis cerana (Ac) and Apis mellifera (Am) share an evolutionarily conserved set of QMP compounds: (E)-9-oxodec-2-enoic acid (9-ODA), (E)-9-hydroxydec-2-enoic acid (9-HDA), (E)-10-hydroxy-dec-2-enoic acid (10-HDA), 10-hydroxy-decanoic acid (10-HDAA), and methyl p-hydroxybenzoate (HOB) found at similar levels. However, evidence suggests there may be species-specific sensitivity differences to QMP compounds because Ac workers have higher levels of ovarian activation than Am workers. Using electroantennograms, we found species-specific sensitivity differences for a blend of the major QMP compounds and three individual compounds (9-HDA, 10-HDAA, and 10-HDA). As predicted, Am was more sensitive than Ac in all cases (1.3- to 2.7- fold higher responses). There were also species differences in worker retinue attraction to three compounds (9-HDA, HOB, and 10-HDA). In all significantly different cases, Am workers were 4.5- to 6.2-fold more strongly attracted than Ac workers were. Thus, Ac workers responded less strongly to QMP than Ac workers, and 9-HDA and 10-HDA consistently elicited stronger antennal and retinue formation responses.
Dong, Shihao; Wen, Ping; Zhang, Qi; Li, Xinyu; Tan, Ken; Nieh, James
2017-03-15
In highly social bees, queen mandibular pheromone (QMP) is vital for colony life. Both Apis cerana (Ac) and Apis mellifera (Am) share an evolutionarily conserved set of QMP compounds: (E)-9-oxodec-2-enoic acid (9-ODA), (E)-9-hydroxydec-2-enoic acid (9-HDA), (E)-10-hydroxy-dec-2-enoic acid (10-HDA), 10-hydroxy-decanoic acid (10-HDAA), and methyl p-hydroxybenzoate (HOB) found at similar levels. However, evidence suggests there may be species-specific sensitivity differences to QMP compounds because Ac workers have higher levels of ovarian activation than Am workers. Using electroantennograms, we found species-specific sensitivity differences for a blend of the major QMP compounds and three individual compounds (9-HDA, 10-HDAA, and 10-HDA). As predicted, Am was more sensitive than Ac in all cases (1.3- to 2.7- fold higher responses). There were also species differences in worker retinue attraction to three compounds (9-HDA, HOB, and 10-HDA). In all significantly different cases, Am workers were 4.5- to 6.2-fold more strongly attracted than Ac workers were. Thus, Ac workers responded less strongly to QMP than Am workers, and 9-HDA and 10-HDA consistently elicited stronger antennal and retinue formation responses [corrected].
Head-shaking nystagmus predicts greater disability in unilateral peripheral vestibulopathy.
Angeli, Simon I; Velandia, Sandra; Snapp, Hillary
2011-01-01
The objective of this study was to determine the association of the bedside test of head-shaking nystagmus (HSN) with patients' self-perceived dizziness handicap as well as this test's sensitivity and specificity in unilateral peripheral vestibular hypofunction. A retrospective case-control study was performed. The study was held at an academic, tertiary referral center. Fifty-three adult patients with unilateral peripheral hypofunction defined by the caloric test of the videonystagmography with documented bedside HSN and who had completed questionnaires of self-perceived dizziness handicap were included. The sensitivity and specificity of the bedside HSN in patients and 10 healthy controls in diagnosing unilateral vestibular hypofunction defined by videonystagmographic caloric testing and by abnormal gain and symmetry of the vestibular-ocular reflex by rotary chair testing were determined. Scores of the screening test of the Dizziness Handicap Index and Functional Level Scale questionnaires were taken. When using the caloric irrigation test as the reference standard for unilateral vestibular hypofunction, the sensitivity, specificity, and positive predictive value of the bedside HSN were 31%, 96%, and 97%, respectively. When comparing with results of rotational chair testing (vestibular-ocular reflex gain and symmetry), the sensitivity of the HSN test increases to 71%. Patients with positive bedside HSN had higher scores (greater self-perceived dizziness handicap) of the Dizziness Handicap Index (P = .049) and higher (worse) scores of the Functional Level Scale (P = .0377) than those with negative bedside HSN (Wilcoxon rank test). Greater perceived handicap was correlated with a positive bedside HSN in patients with unilateral peripheral vestibulopathy. The HSN has sufficient sensitivity to be used as screening test of uncompensated vestibulopathy in this series. However, a negative HSN alone does not rule out the diagnosis of peripheral vestibular dysfunction. Copyright © 2011 Elsevier Inc. All rights reserved.
Amitai, Isabella; Werner, Stephanie; Schicke, Bernd; Burmester, Gerd-Rüdiger; Minet, Olaf; Zabaryło, Urszula; Backhaus, Marina; Ohrndorf, Sarah
2015-09-01
Lightscan is a novel, rapid, low-cost, easily operated and noninvasive imaging technology used to assess inflammatory activity in proximal interphalangeal (PIP) joints. The results are calculated automatically. To our knowledge, this is the first comparative study of photo optical imaging (POI), with clinical examination (CE), disease activity score at 28 joints (DAS28)-erythrocyte sedimentation rate (ESR), and musculoskeletal ultrasonography (US) in healthy subjects and patients with rheumatoid arthritis (RA) or osteoarthritis (OA). There were 688 PIP joints of both hands examined in 87 subjects (38 RA, 21 OA, 28 healthy) by Lightscan and compared with CE for clinically swollen and tender joints, DAS28-ESR (only RA), and US. With US as reference, POI had a sensitivity of 74% and a specificity of 93%. In the receiver-operating curve (ROC) analysis, the Lightscan showed a higher sensitivity and specificity [area under the curve (AUC) 0.879] for the distinction of healthy subjects versus patients (OA, RA) than US in greyscale (GSUS; AUC 0.797) and power Doppler (PDUS; AUC 0.67). POI correlated significantly with GSUS (r 0.473, p < 0.01) and PDUS (r 0.486, p < 0.01). The agreement rates between POI and GSUS were up to 79%, between POI and PDUS up to 92%, and between POI and CE up to 66%. POI did not correlate with DAS28-ESR. The Lightscan is a new technology offering sensitive imaging detection of inflammatory changes in subjects with RA and OA with PIP arthritis. POI was more sensitive than CE and correlated significantly to GSUS and PDUS, while presenting a higher sensitivity and specificity for the detection of healthy subjects versus patients (RA, OA) based on the ROC analysis.
Torres-Duarte, Cristina; Ramos-Torres, Karla M; Rahimoff, René; Cherr, Gary N
2017-08-01
The effects of exposure to either soluble copper (copper sulfate) or copper oxide nanoparticles (nano-CuO) during specific early developmental stages of sea urchin embryos were analyzed. Soluble copper caused significant malformations in embryos (skeletal malformations, delayed development or gut malformations) when present at any given stage, while cleavage stage was the most sensitive to nano-CuO exposure causing skeletal malformations and decreased total antioxidant capacity. The stage specificity was linked to higher endocytic activity during the first hours of development that leads to higher accumulation of copper in specific cells critical for development. Results indicate that nano-CuO results in higher accumulation of copper inside of embryos and this intracellular copper is more persistent as compared to soluble copper. The possible implications later in development are discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Selamat, Rusidah; Zain, Fuziah; Raib, Junidah; Zakaria, Rosini; Marzuki, Mohd Shaffari; Ibrahim, Taziah Fatimah
2011-12-01
To study the validity of the visual clinical assessment of weight relative to length and length relative to age as compared to the World Health Organization (WHO) 2006 standard and National Center for Health Statistics (NCHS) 1977 reference in asssessing the physical growth of children younger than 1 year. A prospective cohort study was carried out among 684 infants attending goverment health clinics in 2 states in Malaysia. Body weight, length, and clinical assessment were measured on the same day for 9 visits, scheduled every month until 6 months of age and every 2 months until 12 months of age. All of the 3 z-scores for weight for age (WAZ), length for age (HAZ), and weight for length (WHZ) were calculated using WHO Anthro for Personal Computers software. The average sensitivity and specificity for the visual clinical assessment for the detection of thinness were higher using the WHO 2006 standard as compared with using NCHS 1977. However, the overall sensitivity of the visual clinical assessment for the detection of thin and lean children was lower from 1 month of age until a year as compared with the WHO 2006 standard and NCHS 1977 reference. The positive predictive value (PPV) for the visual clinical assessment versus the WHO 2006 standard was almost doubled as compared with the PPV of visual clinical assessment versus the NCHS 1977 reference. The overall average sensitivity, specificity, PPV, and negative predictive value for the detection of stunting was higher for visual clinical assessment versus the WHO 2006 standard as compared with visual clinical assessment versus the NCHS 1977 reference. The sensitivity and specificity of visual clinical assessment for the detection of wasting and stunting among infants are better for the WHO 2006 standard than the NCHS 1977 reference.
The role of disgust in patients with hypochondriasis.
Weck, Florian; Esch, Sebastian; Rohrmann, Sonja
2014-01-01
Theoretically, disgust sensitivity and disgust proneness could play an important role in hypochondriasis, since disgust is a defensive emotion widely believed to protect the organism from illness. However, empirical evidence to support this hypothesis has so far been based only on nonclinical samples, so that the importance and specificity of disgust for hypochondriasis remains unclear. In the current study, 36 patients with hypochondriasis, 27 with an anxiety disorder, and 29 healthy controls completed several measures which included the assessment of disgust sensitivity (Scale for the Assessment of Disgust Sensitivity) and disgust proneness (Questionnaire for the Assessment of Disgust Proneness). We found that patients with hypochondriasis and those with an anxiety disorder had higher scores than those of the healthy controls for several measures of disgust proneness. Moreover, measures of hypochondriacal characteristics were associated with those of disgust proneness and disgust sensitivity. However, no differences were found between patients with hypochondriasis and those with anxiety disorders, with respect to disgust proneness and disgust sensitivity. Therefore, it can be assumed that disgust proneness and disgust sensitivity seem to be less specific than previously suggested for the development and maintenance of hypochondriasis.
Sensitization to bovine serum albumin as a possible cause of allergic reactions to vaccines.
de Silva, Rajiva; Dasanayake, W M D K; Wickramasinhe, G D; Karunatilake, Chandima; Weerasinghe, Nayani; Gunasekera, Peshala; Malavige, Gathsaurie Neelika
2017-03-13
Immediate type hypersensitivity to vaccines containing bovine/porcine excipients, such as the measles, mumps and rubella (MMR) vaccine is probably due to sensitization to bovine/porcine gelatin. Most patients with such reactions in Sri Lanka have cow's milk (CM) or beef allergy. We investigated whether those who had beef and CM allergy had a higher incidence of hypersensitivity reactions to vaccines and the possible trigger of such reactions. Twenty patients with immediate type hypersensitivity reactions to vaccines containing bovine/porcine excipients, controls with allergy to beef/pork (n=11) or CM (n=11), and 8 non atopic controls were recruited. Total serum IgE, specific IgE to beef, CM, casein, beta lactoglobulin, gelatin and bovine serum albumin (BSA) by Phadia ImmunoCap and IgE to porcine gelatin by Western blot were evaluated. 11/20, 5/20, 2/20, 2/20, 1/20 and 1/20 patients reported allergic reactions to measles containing, JE, rabies primary chick embryo, pentavalent, diphtheria and tetanus, and adult diphtheria and tetanus vaccines, respectively. Only one patient with allergy to vaccines had gelatin specific IgE, whereas IgE to BSA was seen in 73.3%, 90%, 66.6% and 0 of vaccine, beef or CM allergic and non-atopic controls, respectively. The mean IgE to BSA was higher in patients with allergy to vaccines, although not significant. Specific IgE to BSA was present in 54.7% of children with allergy to CM, of whom 11.8% had high levels (>17.5kUA/L). In contrast, 66.6% of these children did not have specific IgE to β-lactoglobulin, which is one of the major components of whey protein. Gelatin does not appear to play a major role in Sri Lankan children with allergy to vaccines. In contrast, due to the higher levels of BSA specific IgE, sensitization to BSA is possibly playing a role. Copyright © 2017 Elsevier Ltd. All rights reserved.
Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E
1997-01-01
The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.
Assessing behavioural changes in ALS: cross-validation of ALS-specific measures.
Pinto-Grau, Marta; Costello, Emmet; O'Connor, Sarah; Elamin, Marwa; Burke, Tom; Heverin, Mark; Pender, Niall; Hardiman, Orla
2017-07-01
The Beaumont Behavioural Inventory (BBI) is a behavioural proxy report for the assessment of behavioural changes in ALS. This tool has been validated against the FrSBe, a non-ALS-specific behavioural assessment, and further comparison of the BBI against a disease-specific tool was considered. This study cross-validates the BBI against the ALS-FTD-Q. Sixty ALS patients, 8% also meeting criteria for FTD, were recruited. All patients were evaluated using the BBI and the ALS-FTD-Q, completed by a carer. Correlational analysis was performed to assess construct validity. Precision, sensitivity, specificity, and overall accuracy of the BBI when compared to the ALS-FTD-Q, were obtained. The mean score of the whole sample on the BBI was 11.45 ± 13.06. ALS-FTD patients scored significantly higher than non-demented ALS patients (31.6 ± 14.64, 9.62 ± 11.38; p < 0.0001). A significant large positive correlation between the BBI and the ALS-FTD-Q was observed (r = 0.807, p < 0.0001), and no significant correlations between the BBI and other clinical/demographic characteristics indicate good convergent and discriminant validity, respectively. 72% of overall concordance was observed. Precision, sensitivity, and specificity for the classification of severely impaired patients were adequate. However, lower concordance in the classification of mild behavioural changes was observed, with higher sensitivity using the BBI, most likely secondary to BBI items which endorsed behavioural aspects not measured by the ALS-FTD-Q. Good construct validity has been further confirmed when the BBI is compared to an ALS-specific tool. Furthermore, the BBI is a more comprehensive behavioural assessment for ALS, as it measures the whole behavioural spectrum in this condition.
Adamowski, Tomasz; Kiejna, Andrzej; Hadryś, Tomasz
2006-01-01
Authors aimed at testing whether psychiatrists in their diagnostic process obeyed strict ICD-10 diagnostic criteria. Diagnoses made by psychiatrists at discharge were compared with those of SCAN ver.2.1 on admission. Diagnoses obtained by SCAN I-Shell program were compared with clinical diagnoses obtained by psychiatrists in the psychiatric wards according to ICD-10 criteria on 3 levels: diagnostic group (Fc), diagnostic class (Fcc), and diagnostic category (Fcc.c). Validity assessment was obtained with Cohen's Kappa coefficient, sensitivity, specificity and Yule's Y coefficient. On the diagnostic group level, Cohen's kappa was 0.14-0.65, Yule's Y 0.57-0.71. Sensitivity 0.69-0.95 and specificity 0.41-0.94. In psychotic disorders group F2 kappa was 0.65, Yule's Y 0.71, sensitivity 0.69, specificity 0.94. In affective disorders group F3 kappa was 0.31, Yule's Y 0.57, sensitivity 0.95, specificity 0.41. In neurotic disorders group F4 kappa was low 0.14, Yule's Y 0.62, sensitivity 0.95, specificity 0.50. The study showed a higher level of agreement between SCAN and clinical diagnoses in the group of psychotic disorders with exception of schizoaffective disorders, and lower agreement rates in the group of affective and neurotic disorders where the number of SCAN diagnoses outweighed that of the clinical ones. It could be the result of systematic faults in the coding of diagnoses.
Diagnostic value of the basophil activation test in evaluating Hymenoptera venom sensitization.
Peternelj, Andreja; Silar, Mira; Bajrovic, Nissera; Adamic, Katja; Music, Ema; Kosnik, Mitja; Korosec, Peter
2009-01-01
Diagnosis of allergy to Hymenoptera venom is usually confirmed with skin testing and measurement of specific serum IgE antibody, tests which are sometimes inconclusive. In these cases, additional in vitro tests are necessary. The aim of this study was to show the applicability of the basophil activation test in detecting sensitization to Hymenoptera venom and to compare the test sensitivity and clinical positive-predictive value with skin prick tests and measurement of allergen-specific serum IgE. This prospective study was conducted between June 2004 and December 2007 and included a large group of 204 patients. All patients had a history of at least one systemic allergic reaction of Müller grades II-IV after a Hymenoptera sting. We compared results of the basophil activation test, specific serum IgE and skin prick tests with patients' clinical history and data on culprit insects. The overall clinical sensitivities of the basophil activation test, specific serum IgE and skin prick tests were 90%, 76% and 64%, respectively; the clinical positive-predictive values of the three tests were 79%, 73% and 78% for bee venom, 86%, 59% and 43% for wasp venom; and 84%, 77% and 22% for both venoms. Our results revealed a higher clinical sensitivity and comparable or better clinical positive-predictive value of basophil activation tests than skin prick tests and allergen-specific serum IgE in the detection of allergy to Hymenoptera venom.
Zhao, Hua; Wang, Xiaoting; Liu, Dawei; Zhang, Hongmin; He, Huaiwu; Long, Yun
2015-12-15
To evaluate the diagnostic value and potential therapeutic impact of Peking Union Medical College Hospital critical ultrasonic management (PCUM) in the early management of critically ill patients with acute respiratory failure (ARF). Patients admitted into the ICU of Peking Union Medical College Hospital for ARF were consecutively recruited over a 18-month period. Patients were randomly divided into conventional group and PCUM group (critical care ultrasonic examination was added in addition to conventional examinations). The two groups were compared with respect to time to preliminary diagnosis, time to final diagnosis, diagnostic accuracy, time to treatment response, time to other examination. A total of 187 patients were included in this study. The two groups showed no significant differences in general clinical information or final diagnosis (P > 0.05). The PCUM group had a shorter time to preliminary diagnosis, time to final diagnosis, time to treatment response, time to X-ray/CT examination, and a higher diagnostic accuracy than the conventional group (P < 0.001). PCUM had high sensitivity and specificity for the diagnosis of acute respiratory distress syndrome (ARDS) (sensitivity 92.0%, specificity 98.5%), acute pulmonary edema (sensitivity 94.7%, specificity 96.1%), pulmonary consolidation (sensitivity 85.7%, specificity 98.6%), COPD/asthma (sensitivity 84.2%, specificity 98.7%). The PCUM is seem to be an attractive complementary diagnostic tool and able to contribute to an early therapeutic decision for the patients with ARF.
Interoception in pathological health anxiety.
Krautwurst, Susann; Gerlach, Alexander L; Witthöft, Michael
2016-11-01
According to cognitive-behavioral models, pathological health anxiety is triggered and maintained by the perception of mostly mild and benign bodily sensations that are misinterpreted as signs of illness. Arguably, abnormalities in interoception may account for this misguided preoccupation with somatic sensations. Using a multimethod approach, the current study investigated possible abnormalities in interoception in patients with pathological health anxiety (PHA; n = 51) and healthy participants (n = 56). Different types of interoception were assessed with a heartbeat-tracking task and a signal-detection task for nonspecific skin conductance fluctuations (NSCFs task). Patients compared with healthy participants showed a more liberal interoceptive response bias for NSCFs, t(79) = 2.32, p = .02, d = 0.53, 95% confidence interval (CI) (0.30, 0.68). Specifically, patients with a comorbid anxiety disorder compared with healthy participants exhibited a significantly higher interoceptive sensitivity for NSCFs, t(57) = 3.12, p < .01, d = 0.89, 95% CI (0.54, 1.12). No evidence for higher interoceptive sensitivity in PHA (neither in the heartbeat mental tracking task nor in the NSCF task) was observed after accounting for comorbid anxiety disorders. The findings suggest that higher interoceptive sensitivity might not be specific to health anxiety, but rather associated with factors shared with the anxiety disorders. Biased (i.e., more liberal) interoceptive processing appears more specific to health anxiety, but further studies using larger sample sizes and a multimethod approach for the assessment of interoception are needed to more completely unravel the role of interoception in health anxiety. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Rustagi, Tarun; Njei, Basile
2014-08-01
This study aimed to perform a structured meta-analysis of all eligible studies to assess the overall diagnostic use of magnetic resonance cholangiopancreatography (MRCP) alone or with secretin enhancement (secretin-enhanced MRCP [S-MRCP]) in the detection of pancreas divisum. Two authors independently performed a comprehensive search of PubMed, MEDLINE, and the Cochrane Library from inception to September 2013. Studies were included if they allowed construction of 2 × 2 contingency tables of MRCP and/or S-MRCP compared with criterion standard. DerSimonian-Laird random effect models were used to estimate the pooled sensitivity, specificity, specificity, and quantitative receiver operating characteristics. Of 51 citations, 10 studies with 1474 patients were included. Secretin-enhanced MRCP had a higher overall diagnostic performance than MRCP (S-MRCP: pooled sensitivity, 86% [95% confidence interval (CI), 77%-93%]; specificity, 97% [95% CI, 94%-99%]; and area under the curve, 0.93 ± 0.056 compared with MRCP: sensitivity, 52% [95% CI, 45%-59%]; specificity, 97% [95% CI, 94%-99%]; and area under the curve, 0.76 ± 0.104). Pooled diagnostic odds ratios were 72.19 (95% CI, 5.66-938.8) and 23.39 (95% CI, 7.93-69.02) for S-MRCP and MRCP, respectively. Visual inspection of the funnel plot showed low potential for publication bias. Secretin-enhanced MRCP has a much higher diagnostic accuracy than MRCP and should be preferred for diagnosis of pancreas divisum.
Aun, Marcelo Vivolo; Saraiva-Romanholo, Beatriz Mangueira; de Almeida, Francine Maria; Brüggemann, Thayse Regina; Kalil, Jorge; Martins, Milton de Arruda; Arantes-Costa, Fernanda Magalhães; Giavina-Bianchi, Pedro
2015-01-01
ABSTRACT Objective To develop a new experimental model of chronic allergic pulmonary disease induced by house dust mite, with marked production of specific immunoglobulin E (IgE), eosinophilic inflammatory infiltrate in the airways and remodeling, comparing two different routes of sensitization. Methods The protocol lasted 30 days. BALB/c mice were divided into six groups and were sensitized subcutaneously or intraperitoneally with saline (negative control), Dermatophagoides pteronyssinus (Der p) 50 or 500mcg in three injections. Subsequently they underwent intranasal challenge with Der p or saline for 7 days and were sacrificed 24 hours after the last challenge. We evaluated the titration of specific IgE anti-Der p, eosinophilic density in peribronchovascular space and airway remodeling. Results Both animals sensitized intraperitoneally and subcutaneously produced specific IgE anti-Der p. Peribronchovascular eosinophilia increased only in mice receiving lower doses of Der p. However, only the group sensitized with Der p 50mcg through subcutaneously route showed significant airway remodeling. Conclusion In this murine model of asthma, both pathways of sensitization led to the production of specific IgE and eosinophilia in the airways. However, only the subcutaneously route was able to induce remodeling. Furthermore, lower doses of Der p used in sensitization were better than higher ones, suggesting immune tolerance. Further studies are required to evaluate the efficacy of this model in the development of bronchial hyperresponsiveness, but it can already be replicated in experiments to create new therapeutic drugs or immunotherapeutic strategies. PMID:26761554
Wu, Wenjie; Cheng, Peng; Lyu, Jingtong; Zhang, Zehua; Xu, Jianzhong
2018-05-01
We developed a Tag Array chip for detecting first- and second-line anti tuberculosis drug resistance in pulmonary tuberculosis and compared the analytical performance of the gene chip to that of phenotypic drug susceptibility testing (DST). From November 2011 to April 2016.234 consecutive culture-confirmed, clinically and imaging diagnosed patients with pulmonary tuberculosis from Southwest Hospital, Chongqing were enrolled into the study. Specimens collected during sputum or bronchoalveolar lavage fluid from the pulmonary tuberculosis patients were subjected to M. tuberculosis species identification and drug-resistance detection by the Tag Array gene chip, and evaluate the sensitivity and specificity of chip. A total of 186 patients was diagnosed drug-resistant tuberculosis. The detection of rifampicin (RFP), isoniazid (INH), fluoroquinolones (FQS), streptomycin (SM) resistance genes was highly sensitive and specific: however, for detection of amikacin (AMK), capreomycin (CPM), Kanamycin (KM), specificity was higher, but sensitivity was lower. Sensitivity for the detection of a mutation in the eis promoter region could be improved. The detection sensitivity of the EMB resistance gene was low, therefore it is easy to miss a diagnosis of EMB drug resistance, but its specificity was high. Tag Array chip can achieve rapid, accurate and high-throughput detection of tuberculosis resistance in pulmonary tuberculosis, which has important clinical significance and feasibility. Copyright © 2018. Published by Elsevier Ltd.
Labanca, Ludimila; Alves, Cláudia Regina Lindgren; Bragança, Lidia Lourenço Cunha; Dorim, Diego Dias Ramos; Alvim, Cristina Gonçalves; Lemos, Stela Maris Aguiar
2015-01-01
To establish cutoff points for the analysis of the Behavior Observation Form (BOF) of children in the ages of 2 to 23 months and evaluate the sensitivity and specificity by age group and domains (Emission, Reception, and Cognitive Aspects of Language). The sample consisted of 752 children who underwent BOF. Each child was classified as having appropriate language development for the age or having possible risk of language impairment. Performance Indicators (PI) were calculated in each domain as well as the overall PI in all domains. The values for sensitivity and specificity were also calculated. The cutoff points for possible risk of language impairment for each domain and each age group were obtained using the receiver operating characteristics curve. The results of the study revealed that one-third of the assessed children have a risk of language impairment in the first two years of life. The analysis of BOF showed high sensitivity (>90%) in all categories and in all age groups; however, the chance of false-positive results was higher than 20% in the majority of aspects evaluated. It was possible to establish the cutoff points for all categories and age groups with good correlation between sensitivity and specificity, except for the age group of 2 to 6 months. This study provides important contributions to the discussion on the evaluation of the language development of children younger than 2 years.
Evaluation of a prognostic scoring system for dogs managed with hemodialysis.
Perondi, Francesca; Lippi, Ilaria; Ceccherini, Gianila; Marchetti, Veronica; Bernicchi, Lucrezia; Guidi, Grazia
2018-06-24
To investigate prognostic models in a cohort of dogs with acute kidney injury (AKI) and acute on chronic kidney disease (AKI/CKD) managed by hemodialysis. Retrospective study from July 2011 to November 2014. University Veterinary Teaching Hospital. Forty dogs with historical, clinical, imaging, and laboratory findings consistent with AKI or AKI/CKD managed with intermittent hemodialysis were included. Scoring system models previously established by Segev et al for outcome prediction in dogs with AKI were applied to all dogs. Models A, B, and C correctly classified outcomes in 68%, 83%, and 85% of cases, respectively. In our cohort Model A showed sensitivity of 58% and specificity of 86%, Model B showed sensitivity of 79% and specificity of 87%, Model C showed sensitivity of 86% and specificity of 84%. The presence of anuria (P < 0.0002), respiratory complications (P < 0.0001), disseminated intravascular coagulation (DIC) (P = 0.0004), grade of AKI (P = 0.0023), pancreatitis (P = 0.0001), and systemic inflammatory response syndrome (SIRS) (P = 0.0001) was significantly higher in nonsurvivors compared with survivors. In our cohort of patients, Segev's model C showed the best sensitivity and specificity for predicting prognosis, while model A had lower sensitivity. In our cohort of dialysis patients, the presence of respiratory complications, DIC, SIRS, and pancreatitis at hospitalization, were correlated with a poor prognosis. © Veterinary Emergency and Critical Care Society 2018.
Kane, Jeffrey M.; van Mantgem, Phillip J.; Lalemand, Laura; Keifer, MaryBeth
2017-01-01
Managers require accurate models to predict post-fire tree mortality to plan prescribed fire treatments and examine their effectiveness. Here we assess the performance of a common post-fire tree mortality model with an independent dataset of 11 tree species from 13 National Park Service units in the western USA. Overall model discrimination was generally strong, but performance varied considerably among species and sites. The model tended to have higher sensitivity (proportion of correctly classified dead trees) and lower specificity (proportion of correctly classified live trees) for many species, indicating an overestimation of mortality. Variation in model accuracy (percentage of live and dead trees correctly classified) among species was not related to sample size or percentage observed mortality. However, we observed a positive relationship between specificity and a species-specific bark thickness multiplier, indicating that overestimation was more common in thin-barked species. Accuracy was also quite low for thinner bark classes (<1 cm) for many species, leading to poorer model performance. Our results indicate that a common post-fire mortality model generally performs well across a range of species and sites; however, some thin-barked species and size classes would benefit from further refinement to improve model specificity.
Huang, Fang; Wang, Xiao-li; Yang, Lian; Yin, Bin-xia; Geng, Yan; Li, Ting-ting
2008-04-01
To study the clinical value of combined determination of carcinoembryonic antigen (CEA), cytokeratin-19-fragments (CYFRA21-1) and tissue polypeptide specific antigen (TPS) levels in both serum and pleural effusion in the diagnosis of lung cancer. The levels of CEA, CYFRA21-1 and TPS in serum and pleural effusion were measured in 78 patients with lung cancer and 45 patients with benign lung disease by using electrochemiluminescence and ELISA methods respectively. The levels of CEA, CYFRA21-1 and TPS in pleural effusion of patients with lung cancer were much higher than those with benign lung disease (P<0.01). The levels of CEA and TPS in serum of patients with lung cancer were much higher than those with benign lung disease (P<0.05, P<0.01). It was also found that the levels of these tumor markers in pleural effusion were higher and more sensitive than those in sera, especially TPS. TPS showed the highest sensitivity in single tumor marker detection, and TPS+CYFRA21-1+ CEA showed the highest sensitivity and accuracy in combined tumor marker detection for diagnosis of lung cancer in pleural effusion. The combined detection of CEA, CYFRA21-1 and TPS in pleural effusion showed higher sensitivity, better accuracy and higher clinical value than those in serum for diagnosis of lung cancer.
Bass, Chris; Nikou, Dimitra; Donnelly, Martin J; Williamson, Martin S; Ranson, Hilary; Ball, Amanda; Vontas, John; Field, Linda M
2007-01-01
Background Knockdown resistance (kdr) is a well-characterized mechanism of resistance to pyrethroid insecticides in many insect species and is caused by point mutations of the pyrethroid target site the para-type sodium channel. The presence of kdr mutations in Anopheles gambiae, the most important malaria vector in Africa, has been monitored using a variety of molecular techniques. However, there are few reports comparing the performance of these different assays. In this study, two new high-throughput assays were developed and compared with four established techniques. Methods Fluorescence-based assays based on 1) TaqMan probes and 2) high resolution melt (HRM) analysis were developed to detect kdr alleles in An. gambiae. Four previously reported techniques for kdr detection, Allele Specific Polymerase Chain Reaction (AS-PCR), Heated Oligonucleotide Ligation Assay (HOLA), Sequence Specific Oligonucleotide Probe – Enzyme-Linked ImmunoSorbent Assay (SSOP-ELISA) and PCR-Dot Blot were also optimized. The sensitivity and specificity of all six assays was then compared in a blind genotyping trial of 96 single insect samples that included a variety of kdr genotypes and African Anopheline species. The relative merits of each assay was assessed based on the performance in the genotyping trial, the length/difficulty of each protocol, cost (both capital outlay and consumable cost), and safety (requirement for hazardous chemicals). Results The real-time TaqMan assay was both the most sensitive (with the lowest number of failed reactions) and the most specific (with the lowest number of incorrect scores). Adapting the TaqMan assay to use a PCR machine and endpoint measurement with a fluorimeter showed a slight reduction in sensitivity and specificity. HRM initially gave promising results but was more sensitive to both DNA quality and quantity and consequently showed a higher rate of failure and incorrect scores. The sensitivity and specificity of AS-PCR, SSOP-ELISA, PCR Dot Blot and HOLA was fairly similar with a small number of failures and incorrect scores. Conclusion The results of blind genotyping trials of each assay indicate that where maximum sensitivity and specificity are required the TaqMan real-time assay is the preferred method. However, the cost of this assay, particularly in terms of initial capital outlay, is higher than that of some of the other methods. TaqMan assays using a PCR machine and fluorimeter are nearly as sensitive as real-time assays and provide a cost saving in capital expenditure. If price is a primary factor in assay choice then the AS-PCR, SSOP-ELISA, and HOLA are all reasonable alternatives with the SSOP-ELISA approach having the highest throughput. PMID:17697325
Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo
2018-07-01
To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p < 0.01); thinner slice thickness (< 5 mm) showed higher specificity (95%) than thicker slice thickness (81%). Quantitative assessment of ADC is a useful diagnostic tool for differentiating benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.
Performance and limitations of administrative data in the identification of AKI.
Grams, Morgan E; Waikar, Sushrut S; MacMahon, Blaithin; Whelton, Seamus; Ballew, Shoshana H; Coresh, Josef
2014-04-01
Billing codes are frequently used to identify AKI events in epidemiologic research. The goals of this study were to validate billing code-identified AKI against the current AKI consensus definition and to ascertain whether sensitivity and specificity vary by patient characteristic or over time. The study population included 10,056 Atherosclerosis Risk in Communities study participants hospitalized between 1996 and 2008. Billing code-identified AKI was compared with the 2012 Kidney Disease Improving Global Outcomes (KDIGO) creatinine-based criteria (AKIcr) and an approximation of the 2012 KDIGO creatinine- and urine output-based criteria (AKIcr_uop) in a subset with available outpatient data. Sensitivity and specificity of billing code-identified AKI were evaluated over time and according to patient age, race, sex, diabetes status, and CKD status in 546 charts selected for review, with estimates adjusted for sampling technique. A total of 34,179 hospitalizations were identified; 1353 had a billing code for AKI. The sensitivity of billing code-identified AKI was 17.2% (95% confidence interval [95% CI], 13.2% to 21.2%) compared with AKIcr (n=1970 hospitalizations) and 11.7% (95% CI, 8.8% to 14.5%) compared with AKIcr_uop (n=1839 hospitalizations). Specificity was >98% in both cases. Sensitivity was significantly higher in the more recent time period (2002-2008) and among participants aged 65 years and older. Billing code-identified AKI captured a more severe spectrum of disease than did AKIcr and AKIcr_uop, with a larger proportion of patients with stage 3 AKI (34.9%, 19.7%, and 11.5%, respectively) and higher in-hospital mortality (41.2%, 18.7%, and 12.8%, respectively). The use of billing codes to identify AKI has low sensitivity compared with the current KDIGO consensus definition, especially when the urine output criterion is included, and results in the identification of a more severe phenotype. Epidemiologic studies using billing codes may benefit from a high specificity, but the variation in sensitivity may result in bias, particularly when trends over time are the outcome of interest.
Performance and Limitations of Administrative Data in the Identification of AKI
Waikar, Sushrut S.; MacMahon, Blaithin; Whelton, Seamus; Ballew, Shoshana H.; Coresh, Josef
2014-01-01
Background and objectives Billing codes are frequently used to identify AKI events in epidemiologic research. The goals of this study were to validate billing code–identified AKI against the current AKI consensus definition and to ascertain whether sensitivity and specificity vary by patient characteristic or over time. Design, setting, participants, & measurements The study population included 10,056 Atherosclerosis Risk in Communities study participants hospitalized between 1996 and 2008. Billing code–identified AKI was compared with the 2012 Kidney Disease Improving Global Outcomes (KDIGO) creatinine-based criteria (AKIcr) and an approximation of the 2012 KDIGO creatinine- and urine output–based criteria (AKIcr_uop) in a subset with available outpatient data. Sensitivity and specificity of billing code–identified AKI were evaluated over time and according to patient age, race, sex, diabetes status, and CKD status in 546 charts selected for review, with estimates adjusted for sampling technique. Results A total of 34,179 hospitalizations were identified; 1353 had a billing code for AKI. The sensitivity of billing code–identified AKI was 17.2% (95% confidence interval [95% CI], 13.2% to 21.2%) compared with AKIcr (n=1970 hospitalizations) and 11.7% (95% CI, 8.8% to 14.5%) compared with AKIcr_uop (n=1839 hospitalizations). Specificity was >98% in both cases. Sensitivity was significantly higher in the more recent time period (2002–2008) and among participants aged 65 years and older. Billing code–identified AKI captured a more severe spectrum of disease than did AKIcr and AKIcr_uop, with a larger proportion of patients with stage 3 AKI (34.9%, 19.7%, and 11.5%, respectively) and higher in-hospital mortality (41.2%, 18.7%, and 12.8%, respectively). Conclusions The use of billing codes to identify AKI has low sensitivity compared with the current KDIGO consensus definition, especially when the urine output criterion is included, and results in the identification of a more severe phenotype. Epidemiologic studies using billing codes may benefit from a high specificity, but the variation in sensitivity may result in bias, particularly when trends over time are the outcome of interest. PMID:24458075
Bottari, Fabio; Boveri, Sara; Iacobone, Anna Daniela; Gulmini, Chiara; Igidbashian, Sarah; Cassatella, Maria Cristina; Landoni, Fabio; Sandri, Maria Teresa
2018-02-20
High-risk (HR) Human Papilloma Virus (HPV) Tests for HPV detection differ in sensitivity and specificity. In this study, we evaluated the sensitivity and specificity of the HC2 HR HPV Test and the Cobas 4800 HPV Test in consecutive cervical samples collected from a referral population with a high prevalence of disease, using CIN2+ histology as clinical outcome. Ten thousand two-hundred and thirteen consecutive cervical samples were assayed for HR-HPV in the Laboratory Medicine Division of IEO: 5140 from January 2012 to June 2013 with HC2 and 5073 from July 2013 to December 2014 with the Cobas HPV Test. These two assays differ in terms of target genes and testing methods. The test positivity rates for HC2 and Cobas 4800 were 29.5% (1515/5135, 95% CI 28.3-30.8%) and 23.9% (1212/5069, 95% CI 22.7-25.1%), respectively. The detection rates of CIN2+ in the two time periods were 2.8% (145/5140, 95% CI 2.4-3.3%) and 1.6% (79/5073, 95% CI 1.2-1.9%), respectively. The sensitivity for CIN2+ for HC2 and Cobas 4800 was 95.2% (138/145, 95% CI 91.7-98.7%) and 93.7% (74/79, 95% CI 88.3-99.0%), respectively. The specificity for CIN2+ for HC2 and Cobas 4800 was 72.4% (3613/4990, 95% CI 71.2-73.6%) and 77.2% (3852/4990, 95% CI 76.0-78.4%), respectively. There were 23 cases of cancer in each of the two time periods. HC2 detected 100% (23/23). Cobas 4800 detected 82.6% (19/23). The detection rate of CIN2+ was higher in the first period than in the second period. There was no significant difference in sensitivity of HC2 and Cobas 4800 in women with CIN2+. The specificity of CIN2+ using Cobas 4800 in the second period was higher than HC2 in the first period, probably due to the lower prevalence of CIN2+ in the second period.
Han, Pengfei; Keast, Russell S J; Roura, Eugeni
2017-11-01
The influence of sweet taste sensitivity on food intake is not well understood. We investigated the involvement of salivary leptin and SNP of the sweet taste receptor genes (TAS1R2/TAS1R3) on sweet taste sensitivity, sensory-specific satiety (SSS) and macronutrient intake in healthy human adults. In all, nineteen high sweet sensitivity (HS) and eleven low sweet sensitivity (LS) subjects were classified based on the sweetness perception of one solution (9 mm sucrose) forced-choice triangle test. All participants completed a randomised crossover design experiment where they consumed one of three iso-energetic soup preloads differing in primary taste quality (sweet, non-sweet taste-control or no-taste energy-control). A period of 1 h after the preload, participants were offered a buffet meal consisting of foods varying in taste (sweet or non-sweet) and fat content. Subjective measures included hunger/fullness and SSS for sweetness. Saliva and buccal cells were collected to measure leptin level and to study the TAS1R2/TAS1R3 specific SNP, respectively. Salivary leptin concentrations were significantly higher in LS than HS participants (P<0·05). In addition, HS showed stronger sweet SSS compared with LH participants (P<0·05), and consumed less carbohydrate (% energy) and more non-sweet foods than LS (P<0·01 and P<0·05, respectively). Alleles from each TAS1R2 locus (GG compared with AA alleles of rs12033832, and CT/CC compared with TT alleles of rs35874116) were related to higher consumption of carbohydrates (% energy) and higher amount of sweet foods, respectively (P<0·05). In contrast, no associations were found for the TAS1R3 alleles. These results contribute to understand the links between taste sensitivity, macronutrient appetite and food consumption.
Gina, Agarwal; Ying, Jiang; Susan, Rogers Van Katwyk; Chantal, Lemieux; Heather, Orpana; Yang, Mao; Brandan, Hanley; Karen, Davis; Laurel, Leuschen; Howard, Morrison
2018-01-01
Abstract Introduction: First Nations/Métis populations develop diabetes earlier and at higher rates than other Canadians. The Canadian diabetes risk questionnaire (CANRISK) was developed as a diabetes screening tool for Canadians aged 40 years or over. The primary aim of this paper is to assess the effectiveness of the existing CANRISK tool and risk scores in detecting dysglycemia in First Nations/Métis participants, including among those under the age of 40. A secondary aim was to determine whether alternative waist circumference (WC) and body mass index (BMI) cut-off points improved the predictive ability of logistic regression models using CANRISK variables to predict dysglycemia. Methods: Information from a self-administered CANRISK questionnaire, anthropometric measurements, and results of a standard oral glucose tolerance test (OGTT) were collected from First Nations and Métis participants (n = 1479). Sensitivity and specificity of CANRISK scores using published risk score cut-off points were calculated. Logistic regression was conducted with alternative ethnicity-specific BMI and WC cut-off points to predict dysglycemia using CANRISK variables. Results: Compared with OGTT results, using a CANRISK score cut-off point of 33, the sensitivity and specificity of CANRISK was 68% and 63% among individuals aged 40 or over; it was 27% and 87%, respectively among those under 40. Using a lower cut-off point of 21, the sensitivity for individuals under 40 improved to 77% with a specificity of 44%. Though specificity at this threshold was low, the higher level of sensitivity reflects the importance of the identification of high risk individuals in this population. Despite altered cut-off points of BMI and WC, logistic regression models demonstrated similar predictive ability. Conclusion: CANRISK functioned well as a preliminary step for diabetes screening in a broad age range of First Nations and Métis in Canada, with an adjusted CANRISK cutoff point for individuals under 40, and with no incremental improvement from using alternative BMI/WC cut-off points. PMID:29443485
Dixit, Chandra K.; Kadimisetty, Karteek; Otieno, Brunah A.; Tang, Chi; Malla, Spundana; Krause, Colleen E.; Rusling, James F.
2015-01-01
Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. Simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that doesn’t require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for highly sensitive detection of the panel of cancer-specific biomarkers with high specificity and at the same time have the potential to be translated into a POC. PMID:26525998
Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F
2016-01-21
Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.
Xu, Chonggang; Gertner, George
2013-01-01
Fourier Amplitude Sensitivity Test (FAST) is one of the most popular uncertainty and sensitivity analysis techniques. It uses a periodic sampling approach and a Fourier transformation to decompose the variance of a model output into partial variances contributed by different model parameters. Until now, the FAST analysis is mainly confined to the estimation of partial variances contributed by the main effects of model parameters, but does not allow for those contributed by specific interactions among parameters. In this paper, we theoretically show that FAST analysis can be used to estimate partial variances contributed by both main effects and interaction effects of model parameters using different sampling approaches (i.e., traditional search-curve based sampling, simple random sampling and random balance design sampling). We also analytically calculate the potential errors and biases in the estimation of partial variances. Hypothesis tests are constructed to reduce the effect of sampling errors on the estimation of partial variances. Our results show that compared to simple random sampling and random balance design sampling, sensitivity indices (ratios of partial variances to variance of a specific model output) estimated by search-curve based sampling generally have higher precision but larger underestimations. Compared to simple random sampling, random balance design sampling generally provides higher estimation precision for partial variances contributed by the main effects of parameters. The theoretical derivation of partial variances contributed by higher-order interactions and the calculation of their corresponding estimation errors in different sampling schemes can help us better understand the FAST method and provide a fundamental basis for FAST applications and further improvements. PMID:24143037
Xu, Chonggang; Gertner, George
2011-01-01
Fourier Amplitude Sensitivity Test (FAST) is one of the most popular uncertainty and sensitivity analysis techniques. It uses a periodic sampling approach and a Fourier transformation to decompose the variance of a model output into partial variances contributed by different model parameters. Until now, the FAST analysis is mainly confined to the estimation of partial variances contributed by the main effects of model parameters, but does not allow for those contributed by specific interactions among parameters. In this paper, we theoretically show that FAST analysis can be used to estimate partial variances contributed by both main effects and interaction effects of model parameters using different sampling approaches (i.e., traditional search-curve based sampling, simple random sampling and random balance design sampling). We also analytically calculate the potential errors and biases in the estimation of partial variances. Hypothesis tests are constructed to reduce the effect of sampling errors on the estimation of partial variances. Our results show that compared to simple random sampling and random balance design sampling, sensitivity indices (ratios of partial variances to variance of a specific model output) estimated by search-curve based sampling generally have higher precision but larger underestimations. Compared to simple random sampling, random balance design sampling generally provides higher estimation precision for partial variances contributed by the main effects of parameters. The theoretical derivation of partial variances contributed by higher-order interactions and the calculation of their corresponding estimation errors in different sampling schemes can help us better understand the FAST method and provide a fundamental basis for FAST applications and further improvements.
Grant, Angeline; Njiru, James; Okoth, Edgar; Awino, Imelda; Briend, André; Murage, Samuel; Abdirahman, Saida; Myatt, Mark
2018-01-01
A novel approach for improving community case-detection of acute malnutrition involves mothers/caregivers screening their children for acute malnutrition using a mid-upper arm circumference (MUAC) insertion tape. The objective of this study was to test three simple MUAC classification devices to determine whether they improved the sensitivity of mothers/caregivers at detecting acute malnutrition. Prospective, non-randomised, partially-blinded, clinical diagnostic trial describing and comparing the performance of three "Click-MUAC" devices and a MUAC insertion tape. The study took place in twenty-one health facilities providing integrated management of acute malnutrition (IMAM) services in Isiolo County, Kenya. Mothers/caregivers classified their child ( n =1040), aged 6-59 months, using the "Click-MUAC" devices and a MUAC insertion tape. These classifications were compared to a "gold standard" classification (the mean of three measurements taken by a research assistant using the MUAC insertion tape). The sensitivity of mother/caregiver classifications was high for all devices (>93% for severe acute malnutrition (SAM), defined by MUAC < 115 mm, and > 90% for global acute malnutrition (GAM), defined by MUAC < 125 mm). Mother/caregiver sensitivity for SAM and GAM classification was higher using the MUAC insertion tape (100% sensitivity for SAM and 99% sensitivity for GAM) than using "Click-MUAC" devices. Younden's J for SAM classification, and sensitivity for GAM classification, were significantly higher for the MUAC insertion tape (99% and 99% respectively). Specificity was high for all devices (>96%) with no significant difference between the "Click-MUAC" devices and the MUAC insertion tape. The results of this study indicate that, although the "Click-MUAC" devices performed well, the MUAC insertion tape performed best. The results for sensitivity are higher than found in previous studies. The high sensitivity for both SAM and GAM classification by mothers/caregivers with the MUAC insertion tape could be due to the use of an improved MUAC tape design which has a number of new design features. The one-on-one demonstration provided to mothers/caregivers on the use of the devices may also have helped improve sensitivity. The results of this study provide evidence that mothers/caregivers can perform sensitive and specific classifications of their child's nutritional status using MUAC. Clinical trials registration number: NCT02833740.
Kundu, Soumyakanti; Kand, Purushottam; Basu, Sandip
2017-01-01
18-Fluorodeoxyglucose positron emission tomography (FDG-PET) has established a role in the evaluation of several malignancies. However, its precise clinical role in the neural crest cell tumors continues to evolve. The purpose of this study was to compare iodine-131 metaiodobenzylguanidine ( 131 I-MIBG) and FDG-PET of head to head in patients with neural crest tumors both qualitatively and semiquantitatively and to determine their clinical utility in disease status evaluation and further management. A total of 32 patients who had undergone 131 I-MIBG and FDG-PET prospectively were evaluated and clinicopathologically grouped into three categories: neuroblastoma, pheochromocytoma, and medullary carcinoma thyroid. In 18 patients of neuroblastoma, FDG PET and 131 I-MIBG showed patient-specific sensitivity of 84% and 72%, respectively. The mean maximum standardized uptake value (SUV max ) of primary lesions in patients with unfavorable histology was found to be relatively higher than those with favorable histology (5.18 ± 2.38 vs. 3.21 ± 1.69). The mean SUV max of two common sites (posterior superior iliac spine [PSIS] and greater trochanter) was higher in patients with involved marrow than those with uninvolved one (2.36 and 2.75 vs. 1.26 and 1.34, respectively). The ratio of SUV max of the involved/contralateral normal sites was 2.16 ± 1.9. In equivocal bone marrow results, the uptake pattern with SUV estimation can depict metastatic involvement and help in redirecting the biopsy site. Among seven patients of pheochromocytoma, FDG-PET revealed 100% patient-specific sensitivity. FDG-PET detected more metastatic foci than 131 I-MIBG (18 vs. 13 sites). In seven patients of medullary carcinoma thyroid, FDG-PET localized residual, recurrent, or metastatic disease with much higher sensitivity (32 metastatic foci with 72% patient specific sensitivity) than 131 I-MIBG, trending along the higher serum calcitonin levels. FDG-PET is not only a good complementary modality in the management of neural crest cell tumors but also it can even be superior, especially in cases of 131 I-MIBG nonavid tumors.
Contributions of individual face features to face discrimination.
Logan, Andrew J; Gordon, Gael E; Loffler, Gunter
2017-08-01
Faces are highly complex stimuli that contain a host of information. Such complexity poses the following questions: (a) do observers exhibit preferences for specific information? (b) how does sensitivity to individual face parts compare? These questions were addressed by quantifying sensitivity to different face features. Discrimination thresholds were determined for synthetic faces under the following conditions: (i) 'full face': all face features visible; (ii) 'isolated feature': single feature presented in isolation; (iii) 'embedded feature': all features visible, but only one feature modified. Mean threshold elevations for isolated features, relative to full-faces, were 0.84x, 1.08, 2.12, 3.34, 4.07 and 4.47 for head-shape, hairline, nose, mouth, eyes and eyebrows respectively. Hence, when two full faces can be discriminated at threshold, the difference between the eyes is about four times less than what is required when discriminating between isolated eyes. In all cases, sensitivity was higher when features were presented in isolation than when they were embedded within a face context (threshold elevations of 0.94x, 1.74, 2.67, 2.90, 5.94 and 9.94). This reveals a specific pattern of sensitivity to face information. Observers are between two and four times more sensitive to external than internal features. The pattern for internal features (higher sensitivity for the nose, compared to mouth, eyes and eyebrows) is consistent with lower sensitivity for those parts affected by facial dynamics (e.g. facial expressions). That isolated features are easier to discriminate than embedded features supports a holistic face processing mechanism which impedes extraction of information about individual features from full faces. Copyright © 2017 Elsevier Ltd. All rights reserved.
Homšak, Matjaž; Silar, Mira; Berce, Vojko; Tomazin, Maja; Skerbinjek-Kavalar, Maja; Celesnik, Nina; Košnik, Mitja; Korošec, Peter
2013-01-01
Peanut sensitization is common in children. However, it is difficult to assess which children will react mildly and which severely. This study evaluated the relevance of basophil allergen sensitivity testing to distinguish the severity of peanut allergy in children. Twenty-seven peanut-sensitized children with symptoms varying from mild symptoms to severe anaphylaxis underwent peanut CD63 dose-response curve analysis with the inclusion of basophil allergen sensitivity calculation (CD-sens) and peanut component immunoglobulin E (IgE) testing. Eleven children who had experienced anaphylaxis to peanuts showed a markedly higher peanut CD63 response at submaximal allergen concentrations and CD-sens (median 1,667 vs. 0.5; p < 0.0001) than 16 children who experienced a milder reaction. Furthermore, a negative or low CD-sens to peanuts unambiguously excluded anaphylactic peanut allergy. Children with anaphylaxis have higher levels of Ara h 1, 2, 3 and 9 IgE, but comparable levels of IgE to Ara h 8 and whole-peanut extract. The diagnostic specificity calculated with a receiver operating characteristic analysis reached 100% for CD-sens and 73% for Ara h 2. We demonstrated that severe peanut allergy is significantly associated with higher basophil allergen sensitivity. This cellular test should facilitate a more accurate diagnosis of peanut allergy. © 2013 S. Karger AG, Basel.
Sensitivity and specificity of the FAMACHA(©) system in Suffolk sheep and crossbred Boer goats.
Sotomaior, Cristina Santos; Rosalinski-Moraes, Fernanda; da Costa, Alane Rayana Barbosa; Maia, Dhéri; Monteiro, Alda Lúcia Gomes; van Wyk, Jan A
2012-11-23
Sheep and goats are the species of farm animal with the highest growth rate in Paraná State. The main problems facing Paraná State flocks are gastrointestinal parasites and anthelmintic resistance. One of the newest resources used to slow down the development of anthelmintic resistance is the FAMACHA(©) system, a selective method useful for controlling gastrointestinal verminosis in small ruminants. The purpose of the present research was to evaluate the sensitivity and specificity of the FAMACHA(©) system in sheep and goats and to compare the results for both species. The conjunctivae of 83 Suffolk ewes and 60 adult crossbred Boer does were evaluated by the same trained person using the FAMACHA(©) system. The packed cell value (PCV) served as the gold standard for clinical FAMACHA(©) evaluation. To calculate the sensitivity and specificity of the FAMACHA(©) system, different criteria were adopted in turn: animals classified as FAMACHA(©) (F(©)) 4 and 5, or 3, 4 and 5, were considered to be anemic (positive test), and animals classified as F(©)1, 2 and 3, or 1 and 2 were considered to be non-anemic (negative test). Three standard values of PCV, namely ≤19%, ≤18% or ≤15%, were used to confirm anemia. At all cut-off levels, the sensitivity increased if F(©)3 animals were included as being anemic. However, changes in levels of sensitivity were associated with reciprocal changes in specificity. The sensitivity was higher for sheep than for goats, excepting when the criteria included PCV≤18 and F(©)3, F(©)4 and F(©)5 were considered positive. In contrast, the specificity was always lower in sheep for any criteria adopted. Other than in goats, using the ≤15 cut-off level for sheep, it is possible to opt not to drench the animals that were shown to be F(©)3 because the sensitivity is still high, indicating that few animals that should have been drenched were overlooked. In goats, in contrast, the low sensitivity at all cut-off levels made it too risky to leave F(©)3 animals undrenched. Even though the number of correct treatments for goats was always higher than that for sheep, the opposite was true for the kappa index for all the criteria tested. Therefore, the FAMACHA(©) system is suitable for the identification of anemic animals of both species. It is necessary that all small ruminants classified as FAMACHA(©) level 3 are also treated to increase the sensitivity of the method. Copyright © 2012 Elsevier B.V. All rights reserved.
Yu, Cui; Yang, Cuiyun; Song, Shaoyi; Yu, Zixiang; Zhou, Xueping; Wu, Jianxiang
2018-04-04
Iris yellow spot virus (IYSV) is an Orthotospovirus that infects most Allium species. Very few approaches for specific detection of IYSV from infected plants are available to date. We report the development of a high-sensitive Luminex xMAP-based microsphere immunoassay (MIA) for specific detection of IYSV. The nucleocapsid (N) gene of IYSV was cloned and expressed in Escherichia coli to produce the His-tagged recombinant N protein. A panel of monoclonal antibodies (MAbs) against IYSV was generated by immunizing the mice with recombinant N protein. Five specific MAbs (16D9, 11C6, 7F4, 12C10, and 14H12) were identified and used for developing the Luminex xMAP-based MIA systems along with a polyclonal antibody against IYSV. Comparative analyses of their sensitivity and specificity in detecting IYSV from infected tobacco leaves identified 7F4 as the best-performed MAb in MIA. We then optimized the working conditions of Luminex xMAP-based MIA in specific detection of IYSV from infected tobacco leaves by using appropriate blocking buffer and proper concentration of biotin-labeled antibodies as well as the suitable ratio between the antibodies and the streptavidin R-phycoerythrin (SA-RPE). Under the optimized conditions the Luminex xMAP-based MIA was able to specifically detect IYSV with much higher sensitivity than conventional enzyme-linked immunosorbent assay (ELISA). Importantly, the Luminex xMAP-based MIA is time-saving and the whole procedure could be completed within 2.5 h. We generated five specific MAbs against IYSV and developed the Luminex xMAP-based MIA method for specific detection of IYSV in plants. This assay provides a sensitive, high-specific, easy to perform and likely cost-effective approach for IYSV detection from infected plants, implicating potential broad usefulness of MIA in plant virus diagnosis.
LaPrade, Robert F; Ho, Charles P; James, Evan; Crespo, Bernardo; LaPrade, Christopher M; Matheny, Lauren M
2015-01-01
The purpose of this study was to determine the diagnostic accuracy of 3 T MRI, including sensitivity, specificity, negative and positive predictive values, for detection of posterior medial and lateral meniscus root tears and avulsions. All patients who had a 3 T MRI of the knee, followed by arthroscopic surgery, were included in this study. Arthroscopy was considered the gold standard. Meniscus root tears diagnosed at arthroscopy and on MRI were defined as a complete meniscus root detachment within 9 mm of the root. All surgical data were collected prospectively and stored in a data registry. MRI exams were reported prospectively by a musculoskeletal radiologist and reviewed retrospectively. There were 287 consecutive patients (156 males, 131 females; mean age 41.7 years) in this study. Prevalence of meniscus posterior root tears identified at arthroscopy was 9.1, 5.9% for medial and 3.5% for lateral root tears (one patient had both). Sensitivity was 0.770 (95% CI 0.570, 0.901), specificity was 0.729 (95% CI 0.708, 0.741), positive predictive value was 0.220 (95% CI 0.163, 0.257) and negative predictive value was 0.970 (95% CI 0.943, 0.987). For medial root tears, sensitivity was 0.824 (95% CI 0.569, 0.953), specificity was 0.800 (95% CI 0.784, 0.808), positive predictive value was 0.206 (95% CI 0.142, 0.238) and negative predictive value was 0.986 (95% CI 0.967, 0.996). For lateral meniscus posterior root tears, sensitivity was 0.600 (95% CI 0.281, 0.860), specificity was 0.903 (95% CI 0.891, 0.912), positive predictive value was 0.181 (95% CI 0.085, 0.261) and negative predictive value was 0.984 (95% CI 0.972, 0.994). This study demonstrated moderate sensitivity and specificity of 3 T MRI to detect posterior meniscus root tears. The negative predictive value of 3 T MRI to detect posterior meniscus root tears was high; however, the positive predictive value was low. Sensitivity was higher for medial root tears, indicating a higher risk of missing lateral root tears on MRI. Imaging has an important role in identifying meniscus posterior horn root tears; however, some root tears may not be identified until arthroscopy. Prognostic study (diagnostic), Level II.
Laser Doppler assessment of dermal circulatory changes in people with coronary artery disease.
Agarwal, Sharad C; Allen, John; Murray, Alan; Purcell, Ian F
2012-07-01
Dermal microcirculation provides an easily accessible vasculature bed which can be used to assess endothelial mediated vasodilatation. We studied and compared microcirculatory changes in response to acetylcholine iontophoresis (ACh), local heating of the skin and reactive hyperaemia in patients with coronary artery disease (CAD). Forty eight patients with CAD were studied and compared with 25 age and sex matched control subjects. Vasodilatory changes in the dermal microcirculation were assessed in response to ACh iontophoresis, local heating of the skin and reactive hyperaemia using a laser Doppler flowmeter (LDF). Body mass index (BMI) and systolic BP were higher in people with CAD, (p=0.001, 0.043). The perfusion change (measured as absolute in agreement with our previous publish results) in response to ACh iontophoresis, local heating of the skin and reactive hyperaemia, in healthy controls was 234 (190-286), 90 (69-118), 139(106-172) arbitrary perfusion units (APU) compared to 161 (121-214), 50 (39-63), 116(77-143) APU in patients with CAD; p<0.03. The time to peak perfusion in response to reactive hyperaemia was significantly higher in patients with CAD, 14.1±4.0 vs 10.9±1.7s; p=0.001. There was a small but significant positive correlation between the perfusion change in response to ACh iontophoresis and local heating (r=0.31, p=0.035). On ROC curve analysis, perfusion changes with heating had higher sensitivity and specificity in discriminating patients with CAD from the healthy controls with an area under the curve (AUC) of 0.86, with a specificity of 92% and sensitivity of 77% compared to a perfusion changes by reactive hyperaemia, AUC of 0.68 (41% sensitivity and 91% specificity) and ACh iontophoresis, AUC of 0.76 (88% sensitivity and 60% specificity). Vasodilatation in the dermal microcirculation measured by the three techniques is attenuated in patients with coronary artery disease. Local heating of the skin is a better discriminator of patients with CAD than ACh iontophoresis and reactive hyperaemia. Copyright © 2012 Elsevier Inc. All rights reserved.
Validity of parent's self-reported responses to home safety questions.
Osborne, Jodie M; Shibl, Rania; Cameron, Cate M; Kendrick, Denise; Lyons, Ronan A; Spinks, Anneliese B; Sipe, Neil; McClure, Roderick J
2016-09-01
The aim of the study was to describe the validity of parent's self-reported responses to questions on home safety practices for children of 2-4 years. A cross-sectional validation study compared parent's self-administered responses to items in the Home Injury Prevention Survey with home observations undertaken by trained researchers. The relationship between the questionnaire and observation results was assessed using percentage agreement, sensitivity, specificity, positive predictive value, negative predictive value and intraclass correlation coefficients. Percentage agreements ranged from 44% to 100% with 40 of the total 45 items scoring higher than 70%. Sensitivities ranged from 0% to 100%, with 27 items scoring at least 70%. Specificities also ranged from 0% to 100%, with 33 items scoring at least 70%. As such, the study identified a series of self-administered home safety questions that have sensitivities, specificities and predictive values sufficiently high to allow the information to be useful in research and injury prevention practice.
Indoor mite allergens in patients with respiratory allergy living in Porto, Portugal.
Plácido, J L; Cuesta, C; Delgado, L; da Silva, J P; Miranda, M; Ventas, P; Vaz, M
1996-09-01
We investigated the levels of mite allergens (Der p 1, Der f 1, Der 2, and Lep d 1) in dust samples from the homes of 59 patients with asthma, 36 sensitized to house-dust mites (HDM) and 23 to grass pollen (controls), living in Porto, northern Portugal. The relationship between exposure and sensitization to HDM and the influence of housing conditions on mite-allergen levels were also evaluated. Der p 1 (median 9.2 micrograms/g) and Der 2 (4.6 micrograms/g) were the main allergens, while Der f 1 and Lep d 1 levels were always < 1 microgram/g dust and undetectable in 11% and 47% of samples, respectively. All HDM-sensitized asthmatics were exposed to Der p 1 levels > 2 micrograms/g and their homes contained significantly higher levels of Der p 1 (median 12.5 vs 6.4 micrograms/g; P = 0.008) and Der 2 (6.2 vs 3.0 micrograms/g; P = 0.004) when compared to the control group. A significant correlation was observed between the exposure to Der p 1 and the wheal area at skin testing with the Dermatophagoides pteronyssinus (Dp) extract (P = 0.01) as well as with serum specific IgE levels to Dp (P = 0.03). Patients with higher levels of serum specific IgE (> or = 17.5 HRU/ml) were also more frequently exposed to Der p 1 levels > or = 10 micrograms/g (P = 0.002). Old homes, presence of carpets, and signs of dampness were conditions associated with significantly higher levels of mite allergens. In conclusion, we found high levels of Der p 1 and Der 2 particularly in the homes of HDM-sensitized patients and we confirm the relationship between exposure and sensitization to HDM, assessed by both in vivo and in vitro methods. In additional to a favorable outdoor climate, we found in our region housing conditions propitious to mite growth, suggesting that specific geographic characteristics must also be taken into account for the correct planning of mite-avoidance measures.
Sarangmath, Nagaraja; Rattihalli, Rohini; Ragothaman, Mona; Gopalkrishna, Gururaj; Doddaballapur, Subbakrishna; Louis, Elan D; Muthane, Uday B
2005-12-01
The prevalence of Parkinson's disease (PD) is low among Indians, except in the Parsis. Data for Indians come from studies using different screening tools and criteria to detect PD. An epidemiological study in India, which has nearly a billion people, more than 18 spoken languages, and varying levels of literacy, requires development and validation of a screening tool for PD. The objectives of this study are to (1) validate a modified version of a widely used screening questionnaire for PD to suit the needs of the Indian population; (2) compare the use of a nonmedical assistant (NMA) with the use of a medical person during screening; and (3) compare the effect of literacy of participants on the validity of the screening tool. The validity of the questionnaire was tested on 125 participants from a home for the elderly. NMAs of similar background and medical personnel administered the modified screening questionnaire. A movement disorder neurologist blind to the responses on the questionnaire, examined participants independently and diagnosed if participants had PD. The questionnaire was validated in the movement disorders clinic, on known PD patients and their family members without PD. In the movement disorders clinic, sensitivity and specificity of the questionnaire were 100% and 89%, respectively. Fifty-seven participants were included for analysis. The questionnaire had a higher sensitivity when NMAs (75%) rather than the medical personnel (61%) administered it, and its specificity was higher with the medical personnel (61%) than with NMAs (55% and 25%). The questionnaire had a higher specificity in literates than illiterates, whereas sensitivity varied considerably. The modified questionnaire translated in a local Indian language had reasonable sensitivity and can be used to screen individuals for PD in epidemiological studies in India. This questionnaire can be administered by NMAs to screen PD and this strategy would reduce manpower costs. Literacy may influence epidemiological estimates when screening PD.
Procalcitonin and C-reactive protein in urinary tract infection diagnosis.
Xu, Rui-Ying; Liu, Hua-Wei; Liu, Ji-Ling; Dong, Jun-Hua
2014-05-30
Urinary infections are a common type of pediatric disease, and their treatment and prognosis are closely correlated with infection location. Common clinical manifestations and laboratory tests are insufficient to differentiate between acute pyelonephritis and lower urinary tract infection. This study was conducted to explore a diagnostic method for upper and lower urinary tract infection differentiation. The diagnostic values of procalcitonin (PCT) and C-reactive protein (CRP) were analyzed using the receiver operating characteristic curve method for upper and lower urinary tract infection differentiation. PCT was determined using chemiluminescent immunoassay. The PCT and CRP values in children with acute pyelonephritis were significantly higher than those in children with lower urinary tract infection (3.90 ± 3.51 ng/ml and 68.17 ± 39.42 mg/l vs. 0.48 ± 0.39 ng/ml and 21.39 ± 14.92 mg/l). The PCT values were correlated with the degree of renal involvement, whereas the CRP values failed to show such a significant correlation. PCT had a sensitivity of 90.47% and a specificity of 88% in predicting nephropathia, whereas CRP had sensitivity of 85.71% and a specificity of 48%. Both PCT and CRP can be used for upper and lower urinary tract infection differentiation, but PCT has higher sensitivity and specificity in predicting pyelonephritis than CRP. PCT showed better results than CRP. PCT values were also correlated with the degree of renal involvement.
Impacts of simultaneous multislice acquisition on sensitivity and specificity in fMRI.
Risk, Benjamin B; Kociuba, Mary C; Rowe, Daniel B
2018-05-15
Simultaneous multislice (SMS) imaging can be used to decrease the time between acquisition of fMRI volumes, which can increase sensitivity by facilitating the removal of higher-frequency artifacts and boosting effective sample size. The technique requires an additional processing step in which the slices are separated, or unaliased, to recover the whole brain volume. However, this may result in signal "leakage" between aliased locations, i.e., slice "leakage," and lead to spurious activation (decreased specificity). SMS can also lead to noise amplification, which can reduce the benefits of decreased repetition time. In this study, we evaluate the original slice-GRAPPA (no leak block) reconstruction algorithm and acceleration factor (AF = 8) used in the fMRI data in the young adult Human Connectome Project (HCP). We also evaluate split slice-GRAPPA (leak block), which can reduce slice leakage. We use simulations to disentangle higher test statistics into true positives (sensitivity) and false positives (decreased specificity). Slice leakage was greatly decreased by split slice-GRAPPA. Noise amplification was decreased by using moderate acceleration factors (AF = 4). We examined slice leakage in unprocessed fMRI motor task data from the HCP. When data were smoothed, we found evidence of slice leakage in some, but not all, subjects. We also found evidence of SMS noise amplification in unprocessed task and processed resting-state HCP data. Copyright © 2018 Elsevier Inc. All rights reserved.
Review-of-systems questionnaire as a predictive tool for psychogenic nonepileptic seizures.
Robles, Liliana; Chiang, Sharon; Haneef, Zulfi
2015-04-01
Patients with refractory epilepsy undergo video-electroencephalography for seizure characterization, among whom approximately 10-30% will be discharged with the diagnosis of psychogenic nonepileptic seizures (PNESs). Clinical PNES predictors have been described but in general are not sensitive or specific. We evaluated whether multiple complaints in a routine review-of-system (ROS) questionnaire could serve as a sensitive and specific marker of PNESs. We performed a retrospective analysis of a standardized ROS questionnaire completed by patients with definite PNESs and epileptic seizures (ESs) diagnosed in our adult epilepsy monitoring unit. A multivariate analysis of covariance (MANCOVA) was used to determine whether groups with PNES and ES differed with respect to the percentage of complaints in the ROS questionnaire. Tenfold cross-validation was used to evaluate the predictive error of a logistic regression classifier for PNES status based on the percentage of positive complaints in the ROS questionnaire. A total of 44 patients were included for analysis. Patients with PNESs had a significantly higher number of complaints in the ROS questionnaire compared to patients with epilepsy. A threshold of 17% positive complaints achieved a 78% specificity and 85% sensitivity for discriminating between PNESs and ESs. We conclude that the routine ROS questionnaire may be a sensitive and specific predictive tool for discriminating between PNESs and ESs. Published by Elsevier Inc.
Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S
2015-09-01
The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.
Use of shear wave elastography to differentiate benign and malignant breast lesions.
Çebi Olgun, Deniz; Korkmazer, Bora; Kılıç, Fahrettin; Dikici, Atilla Süleyman; Velidedeoğlu, Mehmet; Aydoğan, Fatih; Kantarcı, Fatih; Yılmaz, Mehmet Halit
2014-01-01
We aimed to determine the correlations between the elasticity values of solid breast masses and histopathological findings to define cutoff elasticity values differentiating malignant from benign lesions. A total of 115 solid breast lesions of 109 consecutive patients were evaluated prospectively using shear wave elastography (SWE). Two orthogonal elastographic images of each lesion were obtained. Minimum, mean, and maximum elasticity values were calculated in regions of interest placed over the stiffest areas on the two images; we also calculated mass/fat elasticity ratios. Correlation of elastographic measurements with histopathological results were studied. Eighty-three benign and thirty-two malignant lesions were histopathologically diagnosed. The minimum, mean, and maximum elasticity values, and the mass/fat elasticity ratios of malignant lesions, were significantly higher than those of benign lesions. The cutoff value was 45.7 kPa for mean elasticity (sensitivity, 96%; specificity, 95%), 54.3 kPa for maximum elasticity (sensitivity, 95%; specificity, 94%), 37.1 kPa for minimum elasticity (sensitivity, 96%; specificity, 95%), and 4.6 for the mass/fat elasticity ratio (sensitivity, 97%; specificity, 95%). SWE yields additional valuable quantitative data to ultrasonographic examination on solid breast lesions. SWE may serve as a complementary tool for diagnosis of breast lesions. Long-term clinical studies are required to accurately select lesions requiring biopsy.
Boralevi, F; Hubiche, T; Léauté-Labrèze, C; Saubusse, E; Fayon, M; Roul, S; Maurice-Tison, S; Taïeb, A
2008-02-01
Sensitization to atopens is an early phenomenon that overlaps with the onset of atopic dermatitis (AD) in infancy. Early epidermal barrier impairment may facilitate the epicutaneous penetration of atopens. To correlate transepidermal water loss (TEWL) and aeroallergen sensitization in infants with AD. In this cross-sectional study we enrolled 59 AD children and 30 controls aged 3-12 months. Transepidermal water loss in uninvolved skin, specific immunoglobulin E, atopy patch test (APT) and skin prick tests were performed with respect to seven aeroallergens, i.e., Dermatophagoides pteronyssinus, D. farinae, cat, dog, birch pollen, ambrosia, and cockroach. Environmental conditions were assessed by a questionnaire, and the house dust mite (HDM) concentration was determined in dust samples. Eighty-nine percent of AD infants had a positive APT vs one out of eleven controls. AD infants had a significantly higher mean TEWL than controls (27.4 vs 11.1 g/m(2)/h, P < 0001). Children with two or more positive APT had higher TEWL than the others (31.1 vs 19.0 g/m(2)/h, P < 0.025). No correlation was found between indoor APT results and exposure to HDM, cats, and dogs at home. This study confirms the high prevalence of delayed sensitization to indoor and outdoor aeroallergens in AD infants, and shows that the higher the TEWL, the higher the prevalence of sensitization to aeroallergens. These data are in favor of a major role of a constitutive epidermal barrier impairment in determining early atopen sensitization in infants with AD.
Amini, F; Kachuei, R; Noorbakhsh, F; Imani Fooladi, A A
2015-06-01
The aim of this study was the detection of Aspergillus species and Mycobacterium tuberculosis together in bronchoalveolar lavage (BAL) using of multiplex PCR. In this study, from September 2012 until June 2013, 100 bronchoalveolar lavage (BAL) specimens were collected from patients suspected of tuberculosis (TB). After the direct and culture test, multiplex PCR were utilized in order to diagnose Aspergillus species and M. tuberculosis. Phenol-chloroform manual method was used in order to extract DNA from these microorganisms. Aspergillus specific primers, M. tuberculosis designed primers and beta actin primers were used for multiplex PCR. In this study, by multiplex PCR method, Aspergillus species were identified in 12 samples (12%), positive samples in direct and culture test were respectively 11% and 10%. Sensitivity and specificity of this method in comparison to direct test were respectively 100% and 98.8%, also sensitivity and specificity of this method in comparison to culture test were respectively 100% and 97.7%. In this assay, M. tuberculosis was identified in 8 samples (8%). Mycobacterium-positive samples in molecular method, direct and culture test were respectively 6%, 5% and 7%. Sensitivity and specificity of PCR method in comparison to direct test were 80% and 97.8% also sensitivity and specificity of this method in comparison to culture test was 71.4% and 98.9%. In the present study, multiplex PCR method had higher sensitivity than direct and culture test in order to identify and detect Aspergillus, also this method had lower sensitivity for identification of M. tuberculosis, suggesting that the method of DNA extraction was not suitable. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Cişmileanu, Ana; Sima, Cornelia; Grigoriu, Constantin
2007-08-01
A quantum dot - immunoglobulin conjugate specific for pig IgG, was obtained by carbodiimide chemistry. We used a Western blot technique for detecting specific antibodies against Actinobacillus pleuropneumoniae (A. pp), which cause porcine pleuropneumonia. The antigen used in this technique was Apx haemolysin which is an important virulence factor of A. pp and it induces protective immunity in vaccined pigs. The detection on Western blot membrane was possible at 1/50 dilution of quantum dot conjugate at a dilution of pig serum till 1/6400. The results for pig serum demonstrated a higher sensitivity of QD-based Western blot technique for the presence of antibodies specific for Apx haemolysin in comparison with similar classical techniques (with coloured substrate for enzyme present in secondary antibody conjugate).
Wang, Xiaoyu; Seo, Dong Joo; Lee, Min Hwa
2014-01-01
This study aimed to develop a loop-mediated isothermal amplification (LAMP) method for the rapid detection of Arcobacter species. Specific primers targeting the 23S ribosomal RNA gene were used to detect Arcobacter butzleri, Arcobacter cryaerophilus, and Arcobacter skirrowii. The specificity of the LAMP primer set was assessed using DNA samples from a panel of Arcobacter and Campylobacter species, and the sensitivity was determined using serial dilutions of Arcobacter species cultures. LAMP showed a 10- to 1,000-fold-higher sensitivity than multiplex PCR, with a detection limit of 2 to 20 CFU per reaction in vitro. Whereas multiplex PCR showed cross-reactivity with Campylobacter species, the LAMP method developed in this study was more sensitive and reliable than conventional PCR or multiplex PCR for the detection of Arcobacter species. PMID:24478488
Occult urolithiasis in asymptomatic primary hyperparathyroidism.
Tay, Yu-Kwang Donovan; Liu, Minghao; Bandeira, Leonardo; Bucovsky, Mariana; Lee, James A; Silverberg, Shonni J; Walker, Marcella D
2018-05-01
Recent international guidelines suggest renal imaging to detect occult urolithiasis in all patients with asymptomatic primary hyperparathyroidism (PHPT), but data regarding their prevalence and associated risk factors are limited. We evaluated the prevalence and risk factors for occult urolithiasis. Cross-sectional analysis of 96 asymptomatic PHPT patients from a university hospital in the United States with and without occult nephrolithiasis. Occult urolithiasis was identified in 21% of patients. Stone formers had 47% higher 24-hour urinary calcium excretion (p = 0.002). Although available in only a subset of patients (n = 28), activated vitamin D [1,25(OH) 2 D] was 29% higher (p = 0.02) in stone formers. There was no difference in demographics, BMI, calcium or vitamin D intake, other biochemistries, renal function, BMD, or fractures. Receiver operating characteristic curves indicated that urinary calcium excretion and 1,25(OH) 2 D had an area under the curve of 0.724 (p = 0.003) and 0.750 (p = 0.04), respectively. A urinary calcium threshold of >211mg/day provided a sensitivity of 84.2% and a specificity of 55.3% while a 1,25(OH) 2 D threshold of >91pg/mL provided a sensitivity and specificity of 62.5% and 90.0% respectively for the presence of stones. Occult urolithiasis is present in about one-fifth of patients with asymptomatic PHPT and is associated with higher urinary calcium and 1,25(OH) 2 D. Given that most patients will not have occult urolithiasis, targeted imaging in those most likely to have occult stones rather than screening all asymptomatic PHPT patients may be useful. The higher sensitivity of urinary calcium versus 1,25(OH) 2 D suggests screening those with higher urinary calcium may be an appropriate approach.
Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A
2017-01-01
Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.
He, Fang; Kiener, Tanja K; Lim, Xiao Fang; Tan, Yunrui; Raj, Kattur Venkatachalam Ashok; Tang, Manli; Chow, Vincent T K; Chen, Qingfeng; Kwang, Jimmy
2013-01-01
Human Enterovirus 71 (EV71) is a common cause of hand, foot and mouth disease (HFMD) in young children. It is often associated with severe neurological diseases and mortalities in recent outbreaks across the Asia Pacific region. Currently, there is no efficient universal antibody test available to detect EV71 infections. In the present study, an epitope-blocking ELISA was developed to detect specific antibodies to human EV71 viruses in human or animal sera. The assay relies on a novel monoclonal antibody (Mab 1C6) that specifically binds to capsid proteins in whole EV71 viruses without any cross reaction to any EV71 capsid protein expressed alone. The sensitivity and specificity of the epitope-blocking ELISA for EV71 was evaluated and compared to microneutralization using immunized animal sera to multiple virus genotypes of EV71 and coxsackieviruses. Further, 200 serum sample from human individuals who were potentially infected with EV71 viruses were tested in both the blocking ELISA and microneutralization. Results indicated that antibodies to EV71 were readily detected in immunized animals or human sera by the epitope blocking ELISA whereas specimens with antibodies to other enteroviruses yielded negative results. This assay is not only simpler to perform but also shows higher sensitivity and specificity as compared to microneutralization. The epitope-blocking ELISA based on a unique Mab 1C6 provided highly sensitive and 100% specific detection of antibodies to human EV71 viruses in human sera.
Rosenbach, Charlotte; Renneberg, Babette
2015-03-01
High levels of rejection sensitivity are assumed to be the result of early and prolonged experiences of rejection. Aim of this study was to investigate autobiographical memories of rejection in clinical samples high in rejection sensitivity (Borderline Personality Disorder, BPD, and Major Depressive Disorder, MDD) and to identify group differences in the quality of the memories. Memories of rejection were retrieved using an adapted version of the Autobiographical Memory Test (AMT; five positive cue words, five cue words referring to rejection). Specificity of memories and linguistic word usage was analyzed in 30 patients with BPD, 27 patients with MDD and 30 healthy controls. Patients with BPD retrieved less specific memories compared to the healthy control group, whereas patients with MDD did not differ from controls in this regard. The group difference was no longer significant when controlling for rejection sensitivity. Linguistic analysis indicated that compared to both other groups, patients with BPD showed a higher self-focus, used more anger-related words, referred more frequently to social environments, and rated memories of rejection as more relevant for today's life. Clinical symptoms were not assessed in the control group. Moreover, the written form of the AMT might reduce the total number of specific memories. The level of rejection sensitivity influenced the specificity of the retrieved memories. Analysis of linguistic styles revealed specific linguistic patterns in BPD compared to non-clinical as well as depressed participants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dieker, Jürgen; Berden, Jo H.; Bakker, Marinka; Briand, Jean-Paul; Muller, Sylviane; Voll, Reinhard; Sjöwall, Christopher; Herrmann, Martin; Hilbrands, Luuk B.; van der Vlag, Johan
2016-01-01
Persistent exposure of the immune system to death cell debris leads to autoantibodies against chromatin in patients with systemic lupus erythematosus (SLE). Deposition of anti-chromatin/chromatin complexes can instigate inflammation in multiple organs including the kidney. Previously we identified specific cell death-associated histone modifications as targets of autoantibodies in SLE. In this study we addressed, in a large cohort of SLE patients and controls, the question whether plasma reactivities with specific histone peptides associated with serology and clinical features. Plasma from SLE patients with and without lupus nephritis, disease controls, and healthy controls, were tested in ELISA with histone H4 peptide acetylated at lysines 8, 12 and 16 (H4pac), H2B peptide acetylated at lysine 12 (H2Bpac), H3 peptide trimethylated at lysine 27 (H3pme), and their unmodified equivalents. SLE patients displayed a higher reactivity with the modified equivalent of each peptide. Reactivity with H4pac showed both a high sensitivity (89%) and specificity (91%) for SLE, while H2Bpac exhibited a high specificity (96%) but lower sensitivity (69%). Reactivity with H3pme appeared not specific for SLE. Anti-H4pac and anti-H2Bpac reactivity demonstrated a high correlation with disease activity. Moreover, patients reacting with multiple modified histone peptides exhibited higher SLEDAI and lower C3 levels. SLE patients with renal involvement showed higher reactivity with H2B/H2Bpac and a more pronounced reactivity with the modified equivalent of H3pme and H2Bpac. In conclusion, reactivity with H4pac and H2Bpac is specific for SLE patients and correlates with disease activity, whereas reactivity with H2Bpac is in particular associated with lupus nephritis. PMID:27780265
Akin-Akintayo, Oladunni; Tade, Funmilayo; Mittal, Pardeep; Moreno, Courtney; Nieh, Peter T; Rossi, Peter; Patil, Dattatraya; Halkar, Raghuveer; Fei, Baowei; Master, Viraj; Jani, Ashesh B; Kitajima, Hiroumi; Osunkoya, Adeboye O; Ormenisan-Gherasim, Claudia; Goodman, Mark M; Schuster, David M
2018-05-01
To investigate the disease detection rate, diagnostic performance and interobserver agreement of fluciclovine ( 18 F) PET-CT and multiparametric magnetic resonance imaging (mpMR) in recurrent prostate cancer. Twenty-four patients with biochemical failure after non-prostatectomy definitive therapy, 16/24 of whom had undergone brachytherapy, underwent fluciclovine PET-CT and mpMR with interpretation by expert readers blinded to patient history, PSA and other imaging results. Reference standard was established via a multidisciplinary truth panel utilizing histology and clinical follow-up (22.9 ± 10.5 months) and emphasizing biochemical control. The truth panel was blinded to investigative imaging results. Diagnostic performance and interobserver agreement (kappa) for the prostate and extraprostatic regions were calculated for each of 2 readers for PET-CT (P1 and P2) and 2 different readers for mpMR (M1 and M2). On a whole body basis, the detection rate for fluciclovine PET-CT was 94.7% (both readers), while it ranged from 31.6-36.8% for mpMR. Kappa for fluciclovine PET-CT was 0.90 in the prostate and 1.0 in the extraprostatic regions. For mpMR, kappa was 0.25 and 0.74, respectively. In the prostate, 22/24 patients met the reference standard with 13 malignant and 9 benign results. Sensitivity, specificity and positive predictive value (PPV) were 100.0%, 11.1% and 61.9%, respectively for both PET readers. For mpMR readers, values ranged from 15.4-38.5% for sensitivity, 55.6-77.8% for specificity and 50.0-55.6% for PPV. For extraprostatic disease determination, 18/24 patients met the reference standard. Sensitivity, specificity and PPV were 87.5%, 90.0% and 87.5%, respectively, for fluciclovine PET-CT, while for mpMR, sensitivity ranged from 50 to 75%, specificity 70-80% and PPV 57-75%. The disease detection rate for fluciclovine PET-CT in non-prostatectomy patients with biochemical failure was 94.7% versus 31.6-36.8% for mpMR. For extraprostatic disease detection, fluciclovine PET-CT had overall better diagnostic performance than mpMR. For the treated prostate, fluciclovine PET-CT had high sensitivity though low specificity for disease detection, while mpMR had higher specificity, though low sensitivity. Interobserver agreement was also higher with fluciclovine PET-CT compared with mpMR. Copyright © 2018 Elsevier B.V. All rights reserved.
Ahmad, Tariq; Reshi, Mohammad Latif; Cheshti, M Z; Tanveer, Syed; Shah, Zaffar Amin; Fomada, Bashir Ahmad; Raina, O K
2014-04-01
An evaluation of Gastrothylax crumenifer crude antigen preparation viz., Somatic Antigen (SAg), Excretory Secretory Antigen (ESAg) and Egg Antigen (EAg) in serodiagnosis of disease was undertaken. Test sera samples were obtained from 30 Paramphistomiasis Positive and 30 Gastrothylax free sheep slaughtered at Hazratbal Kashmir. The referral antigenic preparation were evaluated against Paramphistomiasis positive sera, via., control negative sera, using double immunodiffusion test (DID), (IEP) Immunoelectrophoretic assay and ELISA. The performance of referral antigens, as assessed from percent sensitivity and specificity, revealed an increasing trend from DID (Double immunodiffusion-An immunological technique used in the detection, identification and quantification of antibodies and antigens) to IEP (immunoelectrophoresis-A general name for a number of biochemical methods for separation and characterization of proteins based on electrophoresis and reaction with antibodies), followed by ELISA, detecting higher number of sheep positive for paramphistomiasis. In ELISA the ESAg and SAg were evaluated as most reactive antigens with no significant difference and EAg was the least antigenic. In IEP, EAg had the higher sensitivity (60%) and analogous specificity of SAg and ESAg. The formation of the preceptin lines in the proximity to EAg containing wells (cathode end) in IEP was suggestive of higher molecular weight of G. crumenifer specific protein molecules with slower rate of migration. Purification and characterization of G. crumenifer and identification of specific antigenic molecules, particularly in EAg has been suggested for qualitative improvement of diagnostic value of the antigens in the tests used here in.
Jiang, Xiao-Dan; Li, Guang-Yu; Dong, Zhen; Zhu, Dong-Dong
2011-01-01
Skin-prick testing (SPT) is the most common screening method for allergy evaluation. The detection of serum-specific immunoglobulin E (sIgE) is also commonly used. The sensitivity and specificity of these testing methods may vary due to type of causative allergen and type of allergic manifestation. The purpose of this study was to evaluate the correlation between two methods of measuring sIgE (AllergyScreen [Mediwiss Analytic GmbH, Moers, Germany] and ImmunoCAP [Pharmacia, Uppsala, Sweden]) and SPT for the diagnosis of allergic rhinitis (AR). All 216 patients who were referred to the allergist for suspected AR from June to October 2009 had SPT and the two serological tests. One hundred fifty-eight patients had a positive clinical history and a related positive SPT. The SPT was used as reference standard, and we selected three allergens (Dermatophagoides pteronyssinus, mugwort, and ragweed), which were common in fall in northeast China, to analyze the correlation of the two serum tests and SPT. Compared with the SPT, the diagnostic indexes (accuracy, sensitivity and specificity) of the AllergyScreen system and the ImmunoCAP system were 0.819 versus 0.810, 0.780 versus 0.872, and 0.862 versus 0.741, respectively. The accuracy was similar between the two systems (p > 0.05). The ImmunoCAP system method had a higher sensitivity (p < 0.01). The AllergyScreen system had a higher specificity (p < 0.01). These data support that the AllergyScreen system and ImmunoCAP system can identify potentially significant allergens in the diagnosis of AR in patients from northeastern China.
Kane, Elisabeth J; Braunstein, Kara; Ollendick, Thomas H.; Muris, Peter
2014-01-01
The relations of fear to anxiety sensitivity, control beliefs, and maternal overprotection were examined in 126 7- to 13-year-old clinically referred children with specific phobias. Results indicated that anxiety sensitivity and control beliefs were significant predictors of children’s fear levels, accounting for approximately 48% of the total variance. Unexpectedly, age, gender, and maternal overprotection did not emerge as significant predictors of fear in the overall sample. In subsequent analyses, anxiety sensitivity was found to be a consistent, significant predictor for both girls and boys, for both younger and older children, and for children with and without an additional anxiety disorder diagnosis. Control beliefs were only a significant predictor for girls, younger children, and children with an additional anxiety diagnosis. Maternal overprotection was not a significant predictor for any group. Children with an additional anxiety disorder diagnosis had higher levels of fear, anxiety sensitivity, and maternal overprotection, as well as lower levels of control beliefs than the non-additional anxiety disorder subgroup. Future directions and clinical implications are explored. PMID:26273182
Kane, Elisabeth J; Braunstein, Kara; Ollendick, Thomas H; Muris, Peter
2015-07-01
The relations of fear to anxiety sensitivity, control beliefs, and maternal overprotection were examined in 126 7- to 13-year-old clinically referred children with specific phobias. Results indicated that anxiety sensitivity and control beliefs were significant predictors of children's fear levels, accounting for approximately 48% of the total variance. Unexpectedly, age, gender, and maternal overprotection did not emerge as significant predictors of fear in the overall sample. In subsequent analyses, anxiety sensitivity was found to be a consistent, significant predictor for both girls and boys, for both younger and older children, and for children with and without an additional anxiety disorder diagnosis. Control beliefs were only a significant predictor for girls, younger children, and children with an additional anxiety diagnosis. Maternal overprotection was not a significant predictor for any group. Children with an additional anxiety disorder diagnosis had higher levels of fear, anxiety sensitivity, and maternal overprotection, as well as lower levels of control beliefs than the non-additional anxiety disorder subgroup. Future directions and clinical implications are explored.
The CD63 basophil activation test in Hymenoptera venom allergy: a prospective study.
Sturm, G J; Böhm, E; Trummer, M; Weiglhofer, I; Heinemann, A; Aberer, W
2004-10-01
The basophil activation test (BAT), which relies on flow cytometric quantitation of the allergen-induced up-regulation of the granule-associated marker CD63 in peripheral blood basophils, has been suggested to be a useful approach in detecting responsiveness to allergens. The purpose of this study was to establish the usefulness of the BAT with regard to the clinical history and current diagnostic tools in Hymenoptera venom allergy using a prospective study design. Fifty-seven consecutive patients allergic to Hymenoptera venom as defined by a systemic reaction after an insect sting, and 30 age- and sex-matched control subjects with a negative history were included. The degree and nature of sensitization was confirmed by skin testing, specific immunoglobulin E (IgE), serum tryptase levels and BAT. In the nonallergic control group only analysis of specific IgE and BAT were performed. Correlation of BAT, skin test and specific IgE, respectively, with the clinical history in the allergic group was termed as sensitivity and in the control group as specificity. Twenty one of 23 (91.3%) bee venom allergic patients and 29 of 34 (85.3%) patients allergic to wasp and hornet venom tested positive in BAT. The overall sensitivity of BAT, specific IgE and skin tests were 87.7, 91.2 and 93.0%, respectively. The overall specificities were 86.7% for BAT and 66.7% for specific IgE. No correlation between the severity of clinical symptoms and the magnitude of basophil activation was observed. The BAT seems to be an appropriate method to identify patients allergic to bee or wasp venom with a comparable sensitivity to standard diagnostic regimens. The higher specificity of BAT as compared with specific IgE makes this test a useful tool in the diagnosis of Hymenoptera venom allergy.
Sun, Shumei; Zhou, Hao; Zhou, Bin; Hu, Ziyou; Hou, Jinlin; Sun, Jian
2012-05-01
To evaluate the sensitivity and specificity of nested PCR combined with pyrosequencing in the detection of HBV drug-resistance gene. RtM204I (ATT) mutant and rtM204 (ATG) nonmutant plasmids mixed at different ratios were detected for mutations using nested-PCR combined with pyrosequencing, and the results were compared with those by conventional PCR pyrosequencing to analyze the linearity and consistency of the two methods. Clinical specimens with different viral loads were examined for drug-resistant mutations using nested PCR pyrosequencing and nested PCR combined with dideoxy sequencing (Sanger) for comparison of the detection sensitivity and specificity. The fitting curves demonstrated good linearity of both conventional PCR pyrosequencing and nested PCR pyrosequencing (R(2)>0.99, P<0.05). Nested PCR showed a better consistency with the predicted value than conventional PCR, and was superior to conventional PCR for detection of samples containing 90% mutant plasmid. In the detection of clinical specimens, Sanger sequencing had a significantly lower sensitivity than nested PCR pyrosequencing (92% vs 100%, P<0.01). The detection sensitivity of Sanger sequencing varied with the viral loads, especially in samples with low viral copies (HBV DNA ≤3log10 copies/ml), where the sensitivity was 78%, significantly lower than that of pyrosequencing (100%, P<0.01). Neither of the two methods yielded positive results for the negative control samples, suggesting their good specificity. Compared with nested PCR and Sanger sequencing method, nested PCR pyrosequencing has a higher sensitivity especially in clinical specimens with low viral copies, which can be important for early detection of HBV mutant strains and hence more effective clinical management.
Zhang, Lijun; Song, Xiantao; Dong, Li; Li, Jianan; Dou, Ruiyu; Fan, Zhanming; An, Jing; Li, Debiao
2018-04-30
The purpose of the work was to evaluate the incremental diagnostic value of free-breathing, contrast-enhanced, whole-heart, 3 T cardiovascular magnetic resonance coronary angiography (CE-MRCA) to stress/rest myocardial perfusion imaging (MPI) and late gadolinium enhancement (LGE) imaging for detecting coronary artery disease (CAD). Fifty-one patients with suspected CAD underwent a comprehensive cardiovascular magnetic resonance (CMR) examination (CE-MRCA, MPI, and LGE). The additive diagnostic value of MRCA to MPI and LGE was evaluated using invasive x-ray coronary angiography (XA) as the standard for defining functionally significant CAD (≥ 50% stenosis in vessels > 2 mm in diameter). 90.2% (46/51) patients (54.0 ± 11.5 years; 71.7% men) completed CE-MRCA successfully. On per-patient basis, compared to MPI/LGE alone or MPI alone, the addition of MRCA resulted in higher sensitivity (100% vs. 76.5%, p < 0.01), no change in specificity (58.3% vs. 66.7%, p = 0.6), and higher accuracy (89.1% vs 73.9%, p < 0.01) for CAD detection (prevalence = 73.9%). Compared to LGE alone, the addition of CE-MRCA resulted in higher sensitivity (97.1% vs. 41.2%, p < 0.01), inferior specificity (83.3% vs. 91.7%, p = 0.02), and higher diagnostic accuracy (93.5% vs. 54.3%, p < 0.01). The inclusion of successful free-breathing, whole-heart, 3 T CE-MRCA significantly improved the sensitivity and diagnostic accuracy as compared to MPI and LGE alone for CAD detection.
Langenfeld, Matthias R; Forst, Thomas; Standl, Eberhard; Strotmann, Hermann-Josef; Lübben, Georg; Pahler, Sabine; Kann, Peter; Pfützner, Andreas
2004-12-01
This study was performed to compare the specificity and sensitivity of intact proinsulin, adiponectin, and their ratio (proinsulin/adiponectin) in the prediction of insulin resistance as assessed by the homeostasis model assessment (HOMA) score (> or =2 = resistant). Using a cross-sectional approach, 500 orally treated patients with type 2 diabetes (272 women, 238 men; mean +/- SD age, 64.8 +/- 11.6 years; hemoglobin A1c, 7.0 +/- 1.5%; disease duration, 5.8 +/- 6.1 years) were investigated. Various cutoffs for body mass index-adjusted adiponectin and proinsulin/adiponectin were compared with the established cutoff value of 10 pmol/L for fasting proinsulin. Fasting proinsulin correlated more closely with the HOMA score (r = 0.560, P < 0.001) than fasting adiponectin (r = -0.204, P < 0.001) or proinsulin/adiponectin (r = 0.355, P < 0.001). For proinsulin, specificity and sensitivity for insulin resistance in correlation to the HOMA score results were 96% and 70%, respectively. At a comparable specificity level to proinsulin, adiponectin did not reach a comparable sensitivity (14%), while the proinsulin/adiponectin ratio almost reached the same sensitivity (65%). Overall, patients with elevated proinsulin had a higher prevalence of micro- and macrovascular disease [odds ratio 1.47 (adiponectin, 1.08; proinsulin/ adiponectin, 1.48) and 1.34 (adiponectin, 1.32; proinsulin/adiponectin, 1.27), respectively]. Elevation of fasting intact proinsulin seems to be the more specific marker for insulin resistance and increased cardiovascular risk than suppression of fasting adiponectin. Formation of the ratio does not lead to a further increase in the predictive value.
Ahluwalia, Indu B; Helms, Kristen; Morrow, Brian
2013-01-01
We investigated the reliability and validity of three self-reported indicators from the Pregnancy Risk Assessment Monitoring System (PRAMS) survey. We used 2008 PRAMS (n=15,646) data from 12 states that had implemented the 2003 revised U.S. Certificate of Live Birth. We estimated reliability by kappa coefficient and validity by sensitivity and specificity using the birth certificate data as the reference for the following: prenatal participation in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC); Medicaid payment for delivery; and breastfeeding initiation. These indicators were examined across several demographic subgroups. The reliability was high for all three measures: 0.81 for WIC participation, 0.67 for Medicaid payment of delivery, and 0.72 for breastfeeding initiation. The validity of PRAMS indicators was also high: WIC participation (sensitivity = 90.8%, specificity = 90.6%), Medicaid payment for delivery (sensitivity = 82.4%, specificity = 85.6%), and breastfeeding initiation (sensitivity = 94.3%, specificity = 76.0%). The prevalence estimates were higher on PRAMS than the birth certificate for each of the indicators except Medicaid-paid delivery among non-Hispanic black women. Kappa values within most subgroups remained in the moderate range (0.40-0.80). Sensitivity and specificity values were lower for Hispanic women who responded to the PRAMS survey in Spanish and for breastfeeding initiation among women who delivered very low birthweight and very preterm infants. The validity and reliability of the PRAMS data for measures assessed were high. Our findings support the use of PRAMS data for epidemiological surveillance, research, and planning.
Hill, Emily; Bleck, Thomas P; Singh, Kamaljit; Ouyang, Bichun; Busl, Katharina M
2017-06-01
In a febrile patient with a ventriculostomy, diagnosing or excluding bacterial or microbial ventriculitis is difficult, as conventional markers in analysis of cerebrospinal fluid (CSF) are not applicable due to presence of blood and inflammation. CSF lactate has been shown to be a useful indicator of bacterial meningitis in CSF obtained via lumbar puncture, but little and heterogenous data exist on patients with ventriculostomies. We reviewed all CSF analyses obtained via ventriculostomy in patients admitted to our tertiary medical center between 2008 and 2013, and constructed receiver operating characteristic (ROC) curves to evaluate the accuracy of CSF lactate concentration in discriminating a positive CSF culture from a negative one in setting of ventriculostomy and prophylactic antibiosis. Among 467 CSF lactate values, there were 22 corresponding CSF cultures with bacterial growth. Sensitivities and specificities for CSF lactate at threshold values 3, 4, 5 and 6mmol/L showed sensitivity and specificity greater than 70% for CSF lactate threshold 4mmol/L. The lowest threshold value of 3mmol/L resulted in higher sensitivity of 81.8%, and the highest chosen threshold value resulted in high specificity of 94.2%, but these values had poor corresponding specificity and sensitivity, respectively. The area under the curve was 0.82 (95% CI 0.72, 0.91). Our data from a large sample of CSF studies in patients with ventriculostomy indicate that no single value of CSF lactate provided both sensitivity and specificity high enough to be regarded as reliable test. Copyright © 2017 Elsevier B.V. All rights reserved.
Nagata, Satoshi; Hamada, Tomofumi; Yamada, Norishige; Yokoyama, Seiya; Kitamoto, Sho; Kanmura, Yuji; Nomura, Masahiro; Kamikawa, Yoshiaki; Yonezawa, Suguru; Sugihara, Kazumasa
2012-09-01
The early detection of oral squamous cell carcinoma (OSCC) is important, and a screening test with high sensitivity and specificity is urgently needed. Therefore, in this study, the authors investigated the methylation status of tumor-related genes with the objective of establishing a noninvasive method for the detection of OSCC. Oral rinse samples were obtained from 34 patients with OSCC and from 24 healthy individuals (controls). The methylation status of 13 genes was determined by using methylation-specific polymerase chain reaction analysis and was quantified using a microchip electrophoresis system. Promoter methylation in each participant was screened by receiver operating characteristic analysis, and the utility of each gene's methylation status, alone and in combination with other genes, was evaluated as a tool for oral cancer detection. Eight of the 13 genes had significantly higher levels of DNA methylation in samples from patients with OSCC than in controls. The genes E-cadherin (ECAD), transmembrane protein with epidermal growth factor-like and 2 follistatin-like domains 2 (TMEFF2), retinoic acid receptor beta (RARβ), and O-6 methylguanine DNA methyltransferase (MGMT) had high sensitivity (>75%) and specificity for the detection of oral cancer. OSCC was detected with 100% sensitivity and 87.5% specificity using a combination of ECAD, TMEFF2, RARβ, and MGMT and with 97.1% sensitivity and 91.7% specificity using a combination of ECAD, TMEFF2, and MGMT. The aberrant methylation of a combination of marker genes present in oral rinse samples was used to detect OSCC with >90% sensitivity and specificity. The detection of methylated marker genes from oral rinse samples has great potential for the noninvasive detection of OSCC. Copyright © 2012 American Cancer Society.
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Luttrell, M J; McClenahan, P; Hofmann-Wellenhof, R; Fink-Puches, R; Soyer, H P
2012-11-01
Most melanomas are first recognized by patients themselves or by their friends and family. To assess the ability of laypersons to identify melanomas using dermoscopy images. This is an image-based study using laptop computers in the community. Seventeen laypersons were given a one-page educational brochure on the AC Rule for melanoma (asymmetry, colour variation). These laypersons and three expert dermoscopists completed two image sets, each containing a series of 100 pigmented skin lesions. Set 1 contained five melanomas, while set 2 contained 20 melanomas. Participants viewed a clinical image followed by a dermoscopy image for each lesion. For each image a score of 0-10 was assigned for asymmetry and colour, and then an overall assessment was made for suspicion of melanoma. Mean estimates have been calculated for sensitivity and specificity. Laypersons achieved a clinical sensitivity of 91·2% and a significantly higher dermoscopy sensitivity of 94·0%, P = 0·013. This improvement was not associated with a significant change in overall specificity, which for the clinical image was 64·2% and with dermoscopy was 62·0%, P = 0·97. These results indicate that laypersons may be able to use dermoscopy to identify more melanomas than naked eye examination alone. Further study into the practice of dermoscopy by laypersons is warranted. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.
Can histogram analysis of MR images predict aggressiveness in pancreatic neuroendocrine tumors?
De Robertis, Riccardo; Maris, Bogdan; Cardobi, Nicolò; Tinazzi Martini, Paolo; Gobbo, Stefano; Capelli, Paola; Ortolani, Silvia; Cingarlini, Sara; Paiella, Salvatore; Landoni, Luca; Butturini, Giovanni; Regi, Paolo; Scarpa, Aldo; Tortora, Giampaolo; D'Onofrio, Mirko
2018-06-01
To evaluate MRI derived whole-tumour histogram analysis parameters in predicting pancreatic neuroendocrine neoplasm (panNEN) grade and aggressiveness. Pre-operative MR of 42 consecutive patients with panNEN >1 cm were retrospectively analysed. T1-/T2-weighted images and ADC maps were analysed. Histogram-derived parameters were compared to histopathological features using the Mann-Whitney U test. Diagnostic accuracy was assessed by ROC-AUC analysis; sensitivity and specificity were assessed for each histogram parameter. ADC entropy was significantly higher in G2-3 tumours with ROC-AUC 0.757; sensitivity and specificity were 83.3 % (95 % CI: 61.2-94.5) and 61.1 % (95 % CI: 36.1-81.7). ADC kurtosis was higher in panNENs with vascular involvement, nodal and hepatic metastases (p= .008, .021 and .008; ROC-AUC= 0.820, 0.709 and 0.820); sensitivity and specificity were: 85.7/74.3 % (95 % CI: 42-99.2 /56.4-86.9), 36.8/96.5 % (95 % CI: 17.2-61.4 /76-99.8) and 100/62.8 % (95 % CI: 56.1-100/44.9-78.1). No significant differences between groups were found for other histogram-derived parameters (p >.05). Whole-tumour histogram analysis of ADC maps may be helpful in predicting tumour grade, vascular involvement, nodal and liver metastases in panNENs. ADC entropy and ADC kurtosis are the most accurate parameters for identification of panNENs with malignant behaviour. • Whole-tumour ADC histogram analysis can predict aggressiveness in pancreatic neuroendocrine neoplasms. • ADC entropy and kurtosis are higher in aggressive tumours. • ADC histogram analysis can quantify tumour diffusion heterogeneity. • Non-invasive quantification of tumour heterogeneity can provide adjunctive information for prognostication.
Davis, Rachel; Giguère, Steeve
2005-11-15
To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG < 400 mg/dL, sensitivity of assay H (100%) was not significantly different from that of assays C, E, and G (88.9%). Specificity of assays H (96.0%) and G (95.8%) was significantly higher than that of assays C (79.4%) and E (78.1 %). For detection of IgG < 800 mg/dL, sensitivities of assays H (976%), D (92.9%), C (81.0%), and G (81.0%) were significantly higher than that of assay F (52.4%). Specificity of assays F (100%), G (94.7%), and H (82.8%) was significantly higher than that of assays C (56.9%) and D (58.6%). Serum total protein concentration < or = 4.5 g/dL was suggestive of FPT, whereas values > or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.
Lippi, Giuseppe; Mattiuzzi, Camilla; Cervellin, Gianfranco
2013-01-01
An early diagnosis is crucial for effective triage and management of patients with suspected acute myocardial infarction (AMI). Although troponin testing is the cornerstone of diagnosis, the sensitivity of this biomarker is still suboptimal at patient admission. The heart-type fatty acid binding protein (H-FABP) is an early and sensitive biomarker of myocardial ischemia, whose appropriate setting is in combination with troponin testing. We performed a systematic review and meta-analysis of articles that have assessed the combination of troponin and H-FABP in the early diagnosis of AMI. Eight studies, totaling 2735 patients, met the inclusion criteria but none of them used a high-sensitivity troponin immunoassay. The between-study variation was high (98.5%), and attributable to heterogeneity. When considered alone, troponin exhibited a significantly greater pooled area under the curve (AUC) than H-FABP alone (0.820 versus 0.784; p<0.001). The pooled specificity was also higher for troponin alone than for H-FABP alone (0.94 versus 0.83; p<0.001), whereas the cumulative sensitivity was lower for troponin than for H-FABP (0.73 versus 0.80; p=0.02). The combination of both biomarkers exhibited a greater AUC than troponin alone (0.881; p<0.001), as well as a higher pooled sensitivity (0.91; p<0.001), which was however counterbalanced by a lower specificity (0.82; p<0.001). These results attest that the combination of H-FABP with a conventional troponin immunoassay seems advantageous for increasing the sensitivity of the former biomarker, at the expense of a lower specificity. The introduction of H-FABP testing would hence require careful assessment of laboratory data or clinical signs and symptoms for excluding sources of elevation different from AMI. Further studies are needed to assess the diagnostic effectiveness of combining H-FABP with a high-sensitivity troponin immunoassay. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Zhang, Fan; Hu, Lijuan; Wang, Junjun; Chen, Jian; Chen, Jie; Wang, Yumin
2017-09-01
Limited data are available for the diagnostic value, and for the diagnostic sensitivity and specificity of joint detection of serum lactate dehydrogenase (sLDH)/pleural fluid adenosine deaminase (pADA) and pleural fluid carcinoembryonic antigen (pCEA) in malignant pleural effusion (MPE). We collected 987 pleural effusion specimens (of which 318 were malignant pleural effusion, 374 were tubercular pleural effusion, and 295 were parapneumonic effusion specimens) from the First Affiliated Hospital of Wenzhou Medical University from July 2012 to March 2016. The pADA, sLDH, pleural fluid LDH (pLDH), serum C-reactive protein (sCRP), pleural fluid protein, pCEA, white blood cell (WBC), and red blood cell (RBC) were analyzed, and the clinical data of each group were collected for statistical analysis. The level of sLDH/pADA, pCEA, and RBC from the MPE group was markedly higher than the tuberculosis pleural effusion (TB) group (Mann-Whitney U=28422.000, 9278.000, 30518, P=.000, .000, .000) and the parapneumonic pleural fluid group (Mann-Whitney U=5972.500, 7113.000, 36750.500, P=.000, .000, .000). The receiver operating characteristic curve ROC showed that the area under the ROC curve (AUC) (=0.924, 0.841) of pCEA and sLDH/pADA (cutoff=4.9, 10.6) were significantly higher than other markers for the diagnosis of MPE. Thus, joint detection of pCEA and sLDH/pADA suggested that the sensitivity, specificity, and AUC was 0.94, 81.70, and 94.32 at the cutoff 0.16 and diagnostic performance was higher than pCEA or sLDH/pADA. Joint detection of sLDH/pADA and pCEA can be used as a good indicator for the identification of benign and MPE with higher sensitivity and specificity than pCEA or sLDH/pADA. © 2016 Wiley Periodicals, Inc.
Vladimirova, S G; Tarasova, L N; Dokshina, I A; Cherepanova, V A
2014-11-01
The C-reactive protein is a generally recognized marker of inflammation and bacterial infection. However, issue of diagnostic effectiveness of this indicator is still open-ended in case of patients with oncologic hematological diseases. The level of C-reactive protein can increase under neoplastic processes. On the contrary, the inhibition of immune response observed under cytoplastic therapy can decrease synthesis of this protein. The study was organized to establish levels of C-reactive protein as markers of infection in adult patients with acute lymphoblastic leucosis under application of chemotherapy and to evaluate their diagnostic effectiveness. The sampling included 34 patients with acute lymphoblastic leucosis all patients had infectious complications at various stages of treatment. The levels of C-reactive protein in groups of patients with localized infections (mucositis, abscess, pneumonia, etc.) or fever of unknown genesis had no statistical differences but were reliably higher in patients without infectious complications. The concentrations of C-reactive protein in patients with syndrome of systemic inflammatory response and sepsis had no differences. At the same time, level of C-reactive protein under systemic infection (syndrome of systemic inflammatory response, sepsis) was reliably higher than in case of localized infection. The diagnostically reliable levels of C-reactive protein were established as follows: lower than 11 mg/l--infectious complications are lacking; higher than 11 mg/l--availability of infectious process; higher than 82 mg/l--generalization of infection. The given levels are characterized by high diagnostic sensitivity (92% and 97% correspondingly) and specificity (97% and 97%) when patients receive therapy without application of L-asparaginase. At the stages of introduction of this preparation effecting protein synthesizing function of liver sensitivity of proposed criteria are decreased (69% and 55% correspondingly). However; due to high specificity (100% and 96%) their diagnostic effectiveness remains high.
Okazaki, Toshiyuki; Yamamoto, Yoko; Yoda, Keishi; Nagahiro, Shinji
2014-05-15
Previous studies reported that the plasma d-dimer level reflects the activity of thrombus formation in the left atrium of patients with acute cerebral infarction and acute aortic dissection (AAD). Brain natriuretic peptide (BNP) is considered to be a marker of chronic heart failure. The differential diagnosis in the emergency room between stroke due to cardioembolism and AAD is difficult but important for early treatment especially in patients requiring intravenous thrombolysis with a recombinant tissue-type plasminogen activator. We aimed to investigate the association between the plasma d-dimer and BNP levels in patients with cerebral infarction and AAD. We identified 115 consecutive patients with ischemic stroke who were admitted within 72 h of symptom onset and 15 consecutive patients with AAD and measured the level of plasma d-dimer and BNP and the d-dimer:BNP ratio. In patients with AAD the d-dimer level was significantly higher than that in patients with any other stroke subtypes and their BNP level was significantly lower than that in patients with cardioembolic stroke. The d-dimer:BNP ratio was significantly higher in patients with AAD than in those with any other stroke subtype. Compared to patients with a cardioembolic stroke subtype they manifested significantly higher d-dimer levels and d-dimer:BNP ratios suggesting that this ratio may help to diagnose cerebral infarction due to AAD (sensitivity 80%, specificity 93.5%, cut-off 0.074). When the population was limited to patients within 6h of onset, the ratio had higher sensitivity and specificity at the same cut-off value (sensitivity 81.8%, specificity 96.4%). We found that the d-dimer:BNP ratio may be helpful in distinguishing between cerebral infarction with and without AAD. Copyright © 2014 Elsevier B.V. All rights reserved.
Prediction of parturition in bitches utilizing continuous vaginal temperature measurement.
Geiser, B; Burfeind, O; Heuwieser, W; Arlt, S
2014-02-01
The objective of this study was to determine sensitivity and specificity of a body temperature decline in bitches to predict parturition. Temperature loggers were placed into the vaginal cavity of 16 pregnant bitches on day 56-61 after estimated ovulation or first mating. This measurement technique has been validated previously and enabled continuous sampling of body temperature. The temperature loggers were expelled from the vagina before delivery of the first pup. The computed values for specificity (77-92%) were higher than sensitivity (53-69%), indicating a more precise prognosis of parturition not occurring. In conclusion, our findings may assist interpreting vaginal temperature measurements in order to predict parturition in bitches. © 2013 Blackwell Verlag GmbH.
Analysis of Publically Available Skin Sensitization Data from REACH Registrations 2008–2014
Luechtefeld, Thomas; Maertens, Alexandra; Russo, Daniel P.; Rovida, Costanza; Zhu, Hao; Hartung, Thomas
2017-01-01
Summary The public data on skin sensitization from REACH registrations already included 19,111 studies on skin sensitization in December 2014, making it the largest repository of such data so far (1,470 substances with mouse LLNA, 2,787 with GPMT, 762 with both in vivo and in vitro and 139 with only in vitro data). 21% were classified as sensitizers. The extracted skin sensitization data was analyzed to identify relationships in skin sensitization guidelines, visualize structural relationships of sensitizers, and build models to predict sensitization. A chemical with molecular weight > 500 Da is generally considered non-sensitizing owing to low bioavailability, but 49 sensitizing chemicals with a molecular weight > 500 Da were found. A chemical similarity map was produced using PubChem’s 2D Tanimoto similarity metric and Gephi force layout visualization. Nine clusters of chemicals were identified by Blondel’s module recognition algorithm revealing wide module-dependent variation. Approximately 31% of mapped chemicals are Michael’s acceptors but alone this does not imply skin sensitization. A simple sensitization model using molecular weight and five ToxTree structural alerts showed a balanced accuracy of 65.8% (specificity 80.4%, sensitivity 51.4%), demonstrating that structural alerts have information value. A simple variant of k-nearest neighbors outperformed the ToxTree approach even at 75% similarity threshold (82% balanced accuracy at 0.95 threshold). At higher thresholds, the balanced accuracy increased. Lower similarity thresholds decrease sensitivity faster than specificity. This analysis scopes the landscape of chemical skin sensitization, demonstrating the value of large public datasets for health hazard prediction. PMID:26863411
Atabek, Mehmet Emre; Pirgon, Ozgur
2007-02-01
Few previous studies have examined the validity of the fasting glucose-to-insulin ratio (FGIR), homeostasis model assessment of insulin resistance (HOMA-IR) and quantitative insulin-sensitivity check index (QUICKI) in pediatric populations. To compare simple indices of insulin resistance calculated from fasting glucose and insulin levels with insulin sensitivity indices (area under the response curve [AUCinsulin], insulin sensitivity index [ISI-compositeL) determined by oral glucose tolerance testing (OGTT) in obese children. One hundred and forty-eight obese children and adolescents (86 girls and 62 boys, mean age: 10.86 +/- 3.08 years, mean body mass index (BMI): 27.7 +/- 4.2) participated in the study. OGTT was performed in all participants. After glucose and insulin measurements from OGTT, the children were divided into two groups according to the presence or absence of insulin resistance. Insulin sensitivity indices obtained from the OGTT were compared between the groups. The total plasma glucose response and insulin secretion were evaluated from the AUC estimated by the trapezoid rule. Cut-off points, and sensitivity and specificity calculations were based on insulin resistance with receiver operating characteristic curve (ROC) analysis. The prevalence of insulin resistance, glucose intolerance and dyslipidemia was 37.1%, 24.3% and 54% in obese children, respectively. The groups consisted of 93 children without insulin resistance (54 girls and 39 boys; mean age: 10.5 +/- 3.3 years; mean BMI: 27.0 +/- 4.2) and 55 children with insulin resistance (32 girls and 23 boys; mean age: 11.4 +/- 2.5 years; mean BMI: 27.9 +/- 3.9). There were significant differences in mean FGIR (10.0 +/- 7.2 vs 5.6 +/- 2.8, p < 0.001), HOMA-IR (3.2 +/- 2.3 vs 4.9 +/- 2.3, p < 0.001) and QUICKI (0.33 +/- 0.03 vs 0.30 +/- 0.02, p < 0.001) between the groups. The cut-off points for diagnosis of insulin resistance were < 5.6 for FGIR (sensitivity 61.8, specificity 76.3), > 2.7 for HOMA-IR (sensitivity 80, specificity 59.1), and < 0.328 for QUICKI (sensitivity 80, specificity 60.2). Indices derived from fasting samples for diagnosis of insulin sensitivity are reliable criteria in obese children and adolescents. HOMA-IR and QUICKI appeared to have similar sensitivity and specificity and to have higher sensitivity than FGIR.
Brodská, Petra; Panzner, Petr; Pizinger, Karel; Schmid-Grendelmeier, Peter
2014-01-01
Atopic dermatitis (AD) is a common chronic inflammatory skin disease. Malassezia, the predominant skin microbiota fungus, is considered to exacerbate AD, especially in a subset of patients with head and neck type AD (HNAD). In the present study, the relationship between AD and sensitization to Malassezia antigens was investigated. We assessed 173 patients with AD. The severity of eczema was determined with Eczema Area and Severity Index (EASI); the type of AD, namely, head and neck type, was reported as well. The total serum IgE and specific IgE to Malassezia were determined and correlated with clinical picture of AD, sex, age, and the EASI. Total IgE was elevated in 77.7% of patients. Specific IgE to Malassezia was positive (≥0.35 kU/L) in 49.1% of patients. Men were significantly more often sensitized to Malassezia antigen (58% of men vs 42% of women; P value, 0.04). Concurrently, 58% of patients with HNAD versus 42% non-HNAD patients had higher levels of specific IgE to Malassezia, this difference being nearly significant (P value, 0.06). Patients with atopy were also more frequently sensitized to Malassezia. No significant relationship between EASI and the level of total IgE or specific IgE to Malassezia was observed. In our population, IgE-mediated sensitization was found in up to 49% of all patients with AD, most common in men and in head and neck type.
Evaluation and construction of diagnostic criteria for inclusion body myositis
Mammen, Andrew L.; Amato, Anthony A.; Weiss, Michael D.; Needham, Merrilee
2014-01-01
Objective: To use patient data to evaluate and construct diagnostic criteria for inclusion body myositis (IBM), a progressive disease of skeletal muscle. Methods: The literature was reviewed to identify all previously proposed IBM diagnostic criteria. These criteria were applied through medical records review to 200 patients diagnosed as having IBM and 171 patients diagnosed as having a muscle disease other than IBM by neuromuscular specialists at 2 institutions, and to a validating set of 66 additional patients with IBM from 2 other institutions. Machine learning techniques were used for unbiased construction of diagnostic criteria. Results: Twenty-four previously proposed IBM diagnostic categories were identified. Twelve categories all performed with high (≥97%) specificity but varied substantially in their sensitivities (11%–84%). The best performing category was European Neuromuscular Centre 2013 probable (sensitivity of 84%). Specialized pathologic features and newly introduced strength criteria (comparative knee extension/hip flexion strength) performed poorly. Unbiased data-directed analysis of 20 features in 371 patients resulted in construction of higher-performing data-derived diagnostic criteria (90% sensitivity and 96% specificity). Conclusions: Published expert consensus–derived IBM diagnostic categories have uniformly high specificity but wide-ranging sensitivities. High-performing IBM diagnostic category criteria can be developed directly from principled unbiased analysis of patient data. Classification of evidence: This study provides Class II evidence that published expert consensus–derived IBM diagnostic categories accurately distinguish IBM from other muscle disease with high specificity but wide-ranging sensitivities. PMID:24975859
Ibrahim, Osama M A; Dogru, Murat; Ward, Samantha K; Matsumoto, Yukihiro; Wakamatsu, Tais Hitomi; Ishida, Katsushi; Tsuyama, Atsushi; Kojima, Takashi; Shimazaki, Jun; Tsubota, Kazuo
2011-04-06
To evaluate the specificity and sensitivity of strip meniscometry (SM) testing in conjunction with tear function tests in the diagnosis of dry eye (DE) disease and to investigate the effect of SM on reflex tearing. One hundred seven left eyes of 107 patients with definite DE disease according to the Japanese DE diagnostic criteria and 68 left eyes of 68 age- and sex-matched control subjects were studied. Tear meniscus height (TMH) measurements, fluorescein tear film break-up time (FTBUT), fluorescein (F) and rose bengal (RB) staining, and Schirmer's test-1 (ST) were also performed. The assessment of reflex tearing before and after SM application was assessed with a graticule scale at the slit lamp and by optical coherence tomography. The sensitivity and specificity of SM alone and in combination with tear function tests were also sought. The SM scores, TMH measurements, FTBUTs, and STs were significantly lower in dry eye patients than in the controls (P < 0.001). The RB and F staining scores were significantly higher in the dry eye group than in the control group (P < 0.001). The meniscometry strips did not induce significant changes in relation to reflex tearing. SM had an acceptable sensitivity and specificity. SM is a swift, noninvasive, promising method of assessing tear meniscus volume. The combined SM and FTBUT examination appears to be a sensitive approach to the assessment of dry eye disease.
Ronco, Guglielmo; Segnan, Nereo; Giorgi-Rossi, Paolo; Zappa, Marco; Casadei, Gian Piero; Carozzi, Francesca; Dalla Palma, Paolo; Del Mistro, Annarosa; Folicaldi, Stefania; Gillio-Tos, Anna; Nardo, Gaetano; Naldoni, Carlo; Schincaglia, Patrizia; Zorzi, Manuel; Confortini, Massimo; Cuzick, Jack
2006-06-07
Although testing for human papillomavirus (HPV) has higher sensitivity and lower specificity than cytology alone for detecting cervical intraepithelial neoplasia (CIN), studies comparing conventional and liquid-based cytology have had conflicting results. In the first phase of a two-phase multicenter randomized controlled trial, women aged 35-60 years in the conventional arm (n = 16,658) were screened using conventional cytology, and women in the experimental arm (n = 16,706) had liquid-based cytology and were tested for high-risk HPV types using the Hybrid Capture 2 assay. Women in the conventional arm were referred to colposcopy with atypical cells of undetermined significance (ASCUS) or higher and those in the experimental arm were referred with ASCUS or higher cytology or with a positive (> or = 1 pg/mL) HPV test. Sensitivity and positive predictive value (PPV) for detection of cervical intraepithelial neoplasia grade 2 or higher (CIN2+) were calculated. The screening methods and referral criterion applied in the experimental arm had higher sensitivity than that in the conventional arm (relative sensitivity = 1.47; 95% confidence interval [CI] = 1.03 to 2.09) but a lower PPV (relative PPV = 0.40; 95% CI = 0.23 to 0.66). With HPV testing alone at > or = 1 pg/mL and at > or = 2 pg/mL, the gain in sensitivity compared with the conventional arm remained similar (relative sensitivity = 1.43, 95% CI = 1.00 to 2.04 and relative sensitivity = 1.41, 95% CI = 0.98 to 2.01, respectively) but PPV progressively improved (relative PPV = 0.58, 95% CI = 0.33 to 0.98 and relative PPV = 0.75, 95% CI = 0.45 and 1.27, respectively). Referral based on liquid-based cytology alone did not increase sensitivity compared with conventional cytology (relative sensitivity = 1.06; 95% CI = 0.72 to 1.55) but reduced PPV (relative PPV = 0.57; 95% CI = 0.39 to 0.82). HPV testing alone was more sensitive than conventional cytology among women 35-60 years old. Adding liquid-based cytology improved sensitivity only marginally but increased false-positives. HPV testing using Hybrid Capture 2 with a 2 pg/mL cutoff may be more appropriate than a 1 pg/mL cutoff for primary cervical cancer screening.
A two-factor theory for concussion assessment using ImPACT: memory and speed.
Schatz, Philip; Maerlender, Arthur
2013-12-01
We present the initial validation of a two-factor structure of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) using ImPACT composite scores and document the reliability and validity of this factor structure. Factor analyses were conducted for baseline (N = 21,537) and post-concussion (N = 560) data, yielding "Memory" (Verbal and Visual) and "Speed" (Visual Motor Speed and Reaction Time) Factors; inclusion of Total Symptom Scores resulted in a third discrete factor. Speed and Memory z-scores were calculated, and test-retest reliability (using intra-class correlation coefficients) at 1 month (0.88/0.81), 1 year (0.85/0.75), and 2 years (0.76/0.74) were higher than published data using Composite scores. Speed and Memory scores yielded 89% sensitivity and 70% specificity, which was higher than composites (80%/62%) and comparable with subscales (91%/69%). This emergent two-factor structure has improved test-retest reliability with no loss of sensitivity/specificity and may improve understanding and interpretability of ImPACT test results.
Lario, Sergio; Ramírez-Lázaro, María José; Montserrat, Antònia; Quílez, María Elisa; Junquera, Félix; Martínez-Bauer, Eva; Sanfeliu, Isabel; Brullet, Enric; Campo, Rafael; Segura, Ferran; Calvet, Xavier
2016-06-01
Immunochromatographic tests need to be improved in order to enhance their reliability. Recently, several new kits have appeared on the market. The objective was to evaluate the diagnostic accuracy of three monoclonal rapid stool tests - the new Uni-Gold™ H.pylori Antigen (Trinity Biotech, Ireland), the RAPID Hp StAR (Oxoid Ltd., UK) and the ImmunoCard STAT! HpSA (Meridian Diagnostics, USA) - for detecting H. pylori infection prior to eradication treatment. Diagnostic accuracy (sensitivity and specificity) and reliability (concordance between observers) were evaluated in 250 untreated consecutive dyspeptic patients. The gold standard for diagnosing H. pylori infection was defined as the concordance of two or more of rapid urease test (RUT), histopathology and urease breath test (UBT) or positive culture in isolation. Readings of immunochromatographic tests were performed by two different observers. Sensitivity, specificity, positive and negative predictive values and 95% confidence intervals were calculated. Sensitivity and specificity were compared using the McNemar test. The three tests showed a good correlation, with Kappa values>0.9. RAPID Hp StAR had a sensitivity of 91%-92% and a specificity ranging from 77% to 85%. Its sensitivity was higher than that of Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA (p<0.01). Uni-Gold™ H.pylori Antigen kit showed a sensitivity of 83%, similar to ImmunoCard STAT! HpSA. Specificity of Uni-Gold™ H.pylori Antigen approached 90% (87-89%) and was superior to that of RAPID Hp StAR (p<0.01). Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA present similar levels of diagnostic accuracy. RAPID Hp StAR was the most sensitive but less reliable of the three immunochromatographic stool tests. None are as accurate and reliable as UBT, RUT and histology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Weight-elimination neural networks applied to coronary surgery mortality prediction.
Ennett, Colleen M; Frize, Monique
2003-06-01
The objective was to assess the effectiveness of the weight-elimination cost function in improving classification performance of artificial neural networks (ANNs) and to observe how changing the a priori distribution of the training set affects network performance. Backpropagation feedforward ANNs with and without weight-elimination estimated mortality for coronary artery surgery patients. The ANNs were trained and tested on cases with 32 input variables describing the patient's medical history; the output variable was in-hospital mortality (mortality rates: training 3.7%, test 3.8%). Artificial training sets with mortality rates of 20%, 50%, and 80% were created to observe the impact of training with a higher-than-normal prevalence. When the results were averaged, weight-elimination networks achieved higher sensitivity rates than those without weight-elimination. Networks trained on higher-than-normal prevalence achieved higher sensitivity rates at the cost of lower specificity and correct classification. The weight-elimination cost function can improve the classification performance when the network is trained with a higher-than-normal prevalence. A network trained with a moderately high artificial mortality rate (artificial mortality rate of 20%) can improve the sensitivity of the model without significantly affecting other aspects of the model's performance. The ANN mortality model achieved comparable performance as additive and statistical models for coronary surgery mortality estimation in the literature.
Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi
2018-06-01
Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.
2014-01-01
Background Patients with squamous cell carcinoma in the head and neck region (HNSCC) offer a diagnostic challenge due to difficulties to detect small tumours and metastases. Imaging methods available are not sufficient, and radio-immunodiagnostics could increase specificity and sensitivity of diagnostics. The objective of this study was to evaluate, for the first time, the in vivo properties of the radiolabelled CD44v6-targeting fragment AbD15179 and to assess its utility as a targeting agent for radio-immunodiagnostics of CD44v6-expressing tumours. Methods The fully human CD44v6-targeting Fab fragment AbD15179 was labelled with 111In or 125I, as models for radionuclides suitable for imaging with SPECT or PET. Species specificity, antigen specificity and internalization properties were first assessed in vitro. In vivo specificity and biodistribution were then evaluated in tumour-bearing mice using a dual-tumour and dual-isotope setup. Results Both species-specific and antigen-specific binding of the conjugates were demonstrated in vitro, with no detectable internalization. The in vivo studies demonstrated specific tumour binding and favourable tumour targeting properties for both conjugates, albeit with higher tumour uptake, slower tumour dissociation, higher tumour-to-blood ratio and higher CD44v6 sensitivity for the 111In-labelled fragment. In contrast, the 125I-Fab demonstrated more favourable tumour-to-organ ratios for liver, spleen and kidneys. Conclusions We conclude that AbD15179 efficiently targets CD44v6-expressing squamous cell carcinoma xenografts, and particularly, the 111In-Fab displayed high and specific tumour uptake. CD44v6 emerges as a suitable target for radio-immunodiagnostics, and a fully human antibody fragment such as AbD15179 can enable further clinical imaging studies. PMID:24598405
Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed
2016-01-01
The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.
Itai, Shunsuke; Yamada, Shinji; Kaneko, Mika K; Chang, Yao-Wen; Harada, Hiroyuki; Kato, Yukinari
2017-12-01
Epidermal growth factor receptor (EGFR), a receptor tyrosine kinase, activates downstream signaling cascades in many tumors. In this study, we established novel anti-EGFR monoclonal antibodies (mAbs) and characterized their efficacy in flow cytometry, Western blot, and immunohistochemical analyses. We immunized mice with a combination of the extracellular domain of EGFR and EGFR-overexpressing LN229 glioblastoma cells (LN229/EGFR) and performed the first screening using enzyme-linked immunosorbent assay. Next, we selected mAbs using flow cytometry. Among 156 established clones, two mAbs, EMab-51 (IgG 1 , kappa) and EMab-134 (IgG 1 , kappa), reacted with EGFR in Western blot analysis; EMab-134 showed a much higher sensitivity compared with EMab-51. We compared the binding affinities of EMab-51 and EMab-134 using flow cytometry; the calculated K D values for EMab-51 and EMab-134 against SAS cells/HSC-2 cells were 9.2 × 10 -9 M/9.9 × 10 -9 M and 2.6 × 10 -9 M/8.3 × 10 -9 M, respectively, indicating that EMab-134 has a higher affinity to EGFR-expressing cells. Immunohistochemical analysis of EMab-51 and EMab-134 showed sensitive and specific reactions against oral cancer cells; EMab-134 demonstrated a much higher sensitivity (36/38 cases; 94.7%) to oral squamous cell carcinomas compared with EMab-51 (6/38 cases; 15.8%). This novel anti-EGFR mAb, EMab-134, could be advantageous for detecting EGFR in the pathological analysis of EGFR-expressing cancers.
Autofluorescence imaging to optimize 5-ALA-induced fluorescence endoscopy of bladder carcinoma.
Frimberger, D; Zaak, D; Stepp, H; Knüchel, R; Baumgartner, R; Schneede, P; Schmeller, N; Hofstetter, A
2001-09-01
To design an optical system for detecting autofluorescence (AF) of bladder tumors and to determine the success of reducing the false-positive rate of 5-aminolevulinic acid-induced fluorescence endoscopy (AFE). AFE provides significantly higher sensitivity in detecting and localizing bladder carcinoma compared with white light endoscopy. The specificity of AFE is equivalent to white light endoscopy, mostly because of the false-positive fluorescence of chronic cystitis lesions. Laser-induced spectral autofluorescence detection is also an efficient method in the diagnosis of bladder carcinoma. Bladder tissue was excited to AF using the D-Light (375 to 440 nm) after regular AFE with detection of fluorescence-positive areas. The optical image was produced using a special RGB camera. Biopsies were taken from AFE-positive areas, the peritumoral edges, and normal bladder mucosa. The AF images of the suspicious areas were compared with the AFE images and the histologic results. A total of 43 biopsies were histologically examined (24 benign and 19 neoplastic). AF imaging showed contrast differences between papillary tumors, flat lesions, and normal mucosa. The combination of AFE with AF raised the specificity of AFE alone from 67% to 88%. AF imaging is possible. The value of the method in reducing the false-positive rate of the highly sensitive AFE needs to be validated with higher numbers. The combination of AF with AFE had a 20% higher specificity than AFE alone in our study.
Harkness, Kate L; Bruce, Alanna E; Lumley, Margaret N
2006-11-01
This study examined the role of childhood abuse and neglect in sensitizing adolescents to the effects of proximal stressful life events in a cross-sectional sample of 103 depressed and nondepressed adolescents. Consistent with hypotheses, adolescents with a history of childhood abuse and/or neglect reported a lower level of threat of stressful life events prior to episode onset than that reported by those without. This effect was specific to those on their 1st episode of depression and was specific to independent events (i.e., stressors outside of adolescents' control). Further, this effect was robust when controlling for level of chronic difficulties, which was higher in those with childhood abuse and/or neglect. The authors suggest that childhood abuse and/or neglect may be an important risk factor that sensitizes individuals to the effects of acute independent life events. (c) 2006 APA, all rights reserved.
Thurston, Rebecca C; Hernandez, Javier; Del Rio, Jose M; De La Torre, Fernando
2011-07-01
Most midlife women have hot flashes. The conventional criterion (≥2 μmho rise/30 s) for classifying hot flashes physiologically has shown poor performance. We improved this performance in the laboratory with Support Vector Machines (SVMs), a pattern classification method. We aimed to compare conventional to SVM methods to classify hot flashes in the ambulatory setting. Thirty-one women with hot flashes underwent 24 h of ambulatory sternal skin conductance monitoring. Hot flashes were quantified with conventional (≥2 μmho/30 s) and SVM methods. Conventional methods had low sensitivity (sensitivity=.57, specificity=.98, positive predictive value (PPV)=.91, negative predictive value (NPV)=.90, F1=.60), with performance lower with higher body mass index (BMI). SVMs improved this performance (sensitivity=.87, specificity=.97, PPV=.90, NPV=.96, F1=.88) and reduced BMI variation. SVMs can improve ambulatory physiologic hot flash measures. Copyright © 2010 Society for Psychophysiological Research.
Development of mercury (II) ion biosensors based on mercury-specific oligonucleotide probes.
Li, Lanying; Wen, Yanli; Xu, Li; Xu, Qin; Song, Shiping; Zuo, Xiaolei; Yan, Juan; Zhang, Weijia; Liu, Gang
2016-01-15
Mercury (II) ion (Hg(2+)) contamination can be accumulated along the food chain and cause serious threat to the public health. Plenty of research effort thus has been devoted to the development of fast, sensitive and selective biosensors for monitoring Hg(2+). Thymine was demonstrated to specifically combine with Hg(2+) and form a thymine-Hg(2+)-thymine (T-Hg(2+)-T) structure, with binding constant even higher than T-A Watson-Crick pair in DNA duplex. Recently, various novel Hg(2+) biosensors have been developed based on T-rich Mercury-Specific Oligonucleotide (MSO) probes, and exhibited advanced selectivity and excellent sensitivity for Hg(2+) detection. In this review, we explained recent development of MSO-based Hg(2+) biosensors mainly in 3 groups: fluorescent biosensors, colorimetric biosensors and electrochemical biosensors. Copyright © 2015 Elsevier B.V. All rights reserved.
Chambers, Mark A.; Crawshaw, Tim; Waterhouse, Sue; Delahay, Richard; Hewinson, R. Glyn; Lyashchenko, Konstantin P.
2008-01-01
A lateral-flow immunoassay (BrockTB Stat-Pak) for detecting tuberculosis in Eurasian badgers was 49% sensitive and 93% specific against culture for M. bovis (n = 1,464) at necropsy. However, the sensitivity was significantly higher (66 to 78%) in animals with more severe tuberculosis, indicating that the BrockTB Stat-Pak may be useful for the detection of badgers with the greatest risk of transmitting disease. PMID:18272706
Higgins, Nathan C; McLaughlin, Susan A; Rinne, Teemu; Stecker, G Christopher
2017-09-05
Few auditory functions are as important or as universal as the capacity for auditory spatial awareness (e.g., sound localization). That ability relies on sensitivity to acoustical cues-particularly interaural time and level differences (ITD and ILD)-that correlate with sound-source locations. Under nonspatial listening conditions, cortical sensitivity to ITD and ILD takes the form of broad contralaterally dominated response functions. It is unknown, however, whether that sensitivity reflects representations of the specific physical cues or a higher-order representation of auditory space (i.e., integrated cue processing), nor is it known whether responses to spatial cues are modulated by active spatial listening. To investigate, sensitivity to parametrically varied ITD or ILD cues was measured using fMRI during spatial and nonspatial listening tasks. Task type varied across blocks where targets were presented in one of three dimensions: auditory location, pitch, or visual brightness. Task effects were localized primarily to lateral posterior superior temporal gyrus (pSTG) and modulated binaural-cue response functions differently in the two hemispheres. Active spatial listening (location tasks) enhanced both contralateral and ipsilateral responses in the right hemisphere but maintained or enhanced contralateral dominance in the left hemisphere. Two observations suggest integrated processing of ITD and ILD. First, overlapping regions in medial pSTG exhibited significant sensitivity to both cues. Second, successful classification of multivoxel patterns was observed for both cue types and-critically-for cross-cue classification. Together, these results suggest a higher-order representation of auditory space in the human auditory cortex that at least partly integrates the specific underlying cues.
McLaughlin, Susan A.; Rinne, Teemu; Stecker, G. Christopher
2017-01-01
Few auditory functions are as important or as universal as the capacity for auditory spatial awareness (e.g., sound localization). That ability relies on sensitivity to acoustical cues—particularly interaural time and level differences (ITD and ILD)—that correlate with sound-source locations. Under nonspatial listening conditions, cortical sensitivity to ITD and ILD takes the form of broad contralaterally dominated response functions. It is unknown, however, whether that sensitivity reflects representations of the specific physical cues or a higher-order representation of auditory space (i.e., integrated cue processing), nor is it known whether responses to spatial cues are modulated by active spatial listening. To investigate, sensitivity to parametrically varied ITD or ILD cues was measured using fMRI during spatial and nonspatial listening tasks. Task type varied across blocks where targets were presented in one of three dimensions: auditory location, pitch, or visual brightness. Task effects were localized primarily to lateral posterior superior temporal gyrus (pSTG) and modulated binaural-cue response functions differently in the two hemispheres. Active spatial listening (location tasks) enhanced both contralateral and ipsilateral responses in the right hemisphere but maintained or enhanced contralateral dominance in the left hemisphere. Two observations suggest integrated processing of ITD and ILD. First, overlapping regions in medial pSTG exhibited significant sensitivity to both cues. Second, successful classification of multivoxel patterns was observed for both cue types and—critically—for cross-cue classification. Together, these results suggest a higher-order representation of auditory space in the human auditory cortex that at least partly integrates the specific underlying cues. PMID:28827357
Evaluation of commercial skin prick test solutions for selected occupational allergens.
van Kampen, V; de Blay, F; Folletti, I; Kobierski, P; Moscato, G; Olivieri, M; Quirce, S; Sastre, J; Walusiak-Skorupa, J; Kotschy-Lang, N; Müsken, H; Mahler, V; Schliemann, S; Ochmann, U; Sültz, J; Worm, M; Sander, I; Zahradnik, E; Brüning, T; Merget, R; Raulf-Heimsoth, M
2013-01-01
Skin prick testing (SPT) is an important step in the diagnosis of IgE-mediated occupational allergic diseases. The outcome of SPT is related to the quality of allergen extracts. Thus, the aim of the study was to assess different commercially available SPT solutions for selected occupational allergens. SPT was performed in 116 bakers, 47 farmers and 33 subjects exposed to natural rubber latex (NRL), all with work-related allergic symptoms. The SPT solutions from different manufacturers (n = 3-5) for wheat flour, rye flour, soy, cow hair/dander, storage mites (Tyrophagus putrescentiae, Lepidoglyphus destructor, Acarus siro) and NRL were analysed with respect to their protein and antigen contents. SPT was carried out in 16 allergy centres in six European countries using standardized procedures. Specific IgE values were used as the gold standard to calculate the sensitivity and specificity of SPT solutions. The optimal cut-point for each SPT solution was determined by Youden Index. Protein and antigen contents and patterns of the SPT solutions varied remarkably depending on the manufacturer. While SPT solutions for wheat flour and soy reached overall low sensitivities, sensitivities of other tested SPT solutions depended on the manufacturer. As a rule, solutions with higher protein and antigen content showed higher sensitivities and test efficiencies. There is a wide variability of SPT solutions for occupational allergens, and the sensitivity of several solutions is low. Thus, improvement and standardization of SPT solutions for occupational allergens is essential. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
Tran Vu Thieu, Nga; Trinh Van, Tan; Tran Tuan, Anh; Klemm, Elizabeth J; Nguyen Ngoc Minh, Chau; Voong Vinh, Phat; Pham Thanh, Duy; Ho Ngoc Dan, Thanh; Pham Duc, Trung; Langat, Pinky; Martin, Laura B; Galan, Jorge; Liang, Li; Felgner, Philip L; Davies, D Huw; de Jong, Hanna K; Maude, Rapeephan R; Fukushima, Masako; Wijedoru, Lalith; Ghose, Aniruddha; Samad, Rasheda; Dondorp, Arjen M; Faiz, Abul; Darton, Thomas C; Pollard, Andrew J; Thwaites, Guy E; Dougan, Gordon; Parry, Christopher M; Baker, Stephen
2017-08-01
The diagnosis of typhoid fever is a challenge. Aiming to develop a typhoid diagnostic we measured antibody responses against Salmonella Typhi (S. Typhi) protein antigens and the Vi polysaccharide in a cohort of Bangladeshi febrile patients. IgM against 12 purified antigens and the Vi polysaccharide was measured by ELISA in plasma from patients with confirmed typhoid fever (n = 32), other confirmed infections (n = 17), and healthy controls (n = 40). ELISAs with the most specific antigens were performed on plasma from 243 patients with undiagnosed febrile disease. IgM against the S. Typhi protein antigens correlated with each other (rho > 0.8), but not against Vi (rho < 0.6). Typhoid patients exhibited higher IgM against 11/12 protein antigens and Vi than healthy controls and those with other infections. Vi, PilL, and CdtB exhibited the greatest sensitivity and specificity. Specificity and sensitivity was improved when Vi was combined with a protein antigen, generating sensitivities and specificities of 0.80 and >0.85, respectively. Applying a dynamic cut-off to patients with undiagnosed febrile disease suggested that 34-58% had an IgM response indicative of typhoid. We evaluated the diagnostic potential of several S. Typhi antigens; our assays give good sensitivity and specificity, but require further assessment in differing patient populations. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Kimura, Akio; Kobayashi, Kentaro; Yamaguchi, Hitoshi; Takahashi, Takeshi; Harada, Masahiro; Honda, Hideki; Mori, Yoshio; Hirose, Keika; Tanaka, Noriko
2016-09-09
To ensure good outcomes in the management of subarachnoid haemorrhage (SAH), accurate prediction is crucial for initial assessment of patients presenting with acute headache. We conducted this study to develop a new clinical decision rule using only objectively measurable predictors to exclude SAH, offering higher specificity than the previous Ottawa SAH Rule while maintaining comparable sensitivity. Multicentre prospective cohort study. Tertiary-care emergency departments of five general hospitals in Japan from April 2011 to March 2014. Eligible patients comprised 1781 patients aged >15 years with acute headache, excluding trauma or toxic causes and patients who presented in an unconscious state. Definitive diagnosis of SAH was based on confirmation of SAH on head CT or lumbar puncture findings of non-traumatic red blood cells or xanthochromia. A total of 1561 patients were enrolled in this study, of whom 277 showed SAH. Using these enrolled patients, we reached a rule with mainly categorical predictors used in previous reports, called the 'Ottawa-like rule', offering 100% sensitivity when using any of age ≥40 years, neck pain or stiffness, altered level of consciousness or onset during exertion. Using the 1317 patients from whom blood samples were obtained, a new rule using any of systolic blood pressure >150 mm Hg, diastolic blood pressure >90 mm Hg, blood sugar >115 mg/dL or serum potassium <3.9 mEq/L offered 100% sensitivity (95% CI 98.6% to 100%) and 14.5% specificity (12.5% to 16.9%), while the Ottawa-like rule showed the same sensitivity with a lower specificity of 8.8% (7.2% to 10.7%). While maintaining equal sensitivity, our new rule seemed to offer higher specificity than the previous rules proposed by the Ottawa group. Despite the need for blood sampling, this method can reduce unnecessary head CT in patients with acute headache. UMIN 00004871. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Lv, Chao; Hong, Yang; Fu, Zhiqiang; Lu, Ke; Cao, Xiaodan; Wang, Tao; Zhu, Chuangang; Li, Hao; Xu, Rui; Jia, Bingguang; Han, Qian; Dou, Xuefeng; Shen, Yuanxi; Zhang, Zuhang; Zai, Jinli; Feng, Jintao; Lin, Jiaojiao
2016-03-09
Schistosomiasis is a huge threat to human and animal health. Apart from bovines, goats play an important role in the transmission of schistosomiasis in some endemic areas of China. An accessible, quality-assured goat schistosomiasis diagnostic technique is needed. Recently, our laboratory identified two recombinant diagnostic antigens, SjPGM and SjRAD23 via an immuno-proteomic method. The application of these two recombinant antigens to develop a higher sensitivity and specificity technique for the sheep schistosomiasis diagnosis is urgently needed. Epitopes of SjPGM and SjRAD23 were predicted and three polypeptides, two from SjRAD23 and one from SjPGM, were selected. Recombinant plasmids containing two to three DNA sequences encoding predicted polypeptides or large hydrophilic region of Sj23 (LHD-Sj23) were constructed and expressed. Eight recombinant schistosome antigens including four multi-epitope proteins and four recombinant single-molecule antigens as well as SEA, were assessed by ELISA in 91 sera from schistosome-infected goats, 44 sera from non-infected goats, 37 sera from Orientobilharzia-infected goats, and 12 from Haemonchus contortus-infected goats. ELISA tests showed that three multi-epitope proteins had higher sensitivity than the four single-molecule antigens (rSjRAD23, rSjPGM, rBSjRAD23-1, rBSj23) and the multi-epitope protein rBSjPGM-BSjRAD23-1-BSj23 had the highest sensitivity (97.8 %, 89/91) and maintained good specificity (100 %, 44/44) as well as low cross-reactivity with haemonchosis (8.33 %, 3/12) and orientobilharziasis (13.51 %, 5/37) in the diagnosis of goat schistosomiasis. In contrast, when SEA was applied as a diagnosis antigen, it had 100 % (91/91) sensitivity, 75 % (33/44) specificity, 25 and 83.78 % cross-reactivity with haemonchosis (3/12) and orientobilharziasis (31/37), respectively. The application of recombinant multi-epitope proteins may increase the sensitivity of diagnosis technique and retain high specificity of single-molecule antigens for schistosomiasis, and the recombinant antigen rBSjPGM-BSjRAD23-1-BSj23 has the potential to be used as a diagnosis antigen for goat schistosomiasis.
Neuropad for the detection of cardiovascular autonomic neuropathy in patients with type 2 diabetes.
Mendivil, Carlos O; Kattah, William; Orduz, Arturo; Tique, Claudia; Cárdenas, José L; Patiño, Jorge E
2016-01-01
Cardiovascular autonomic neuropathy (CAN) is a prevalent and neglected chronic complication of diabetes, with a large impact on morbidity and mortality. Part of the reason why it is not detected and treated opportunely is because of the complexity of the tests required for its diagnosis. We evaluated the Neuropad®, a test based on sudomotor function, as a screening tool for CAN in adult patients with type 2 diabetes in Bogotá, Colombia. This was a cross-sectional evaluation of Neuropad® for the detection of CAN. Patients were 20-75years of age and did not suffer from any other type of neuropathy. CAN was diagnosed using the Ewing battery of tests for R-R variability during deep breathing, Valsalva and lying-to-standing maneuvers. Additionally, distal symmetric polyneuropathy (DSP) was diagnosed using a sign-based scale (Michigan Neuropathy Disability Score - NDS) and a symptom-based score (Total Symptom Score - TSS). The primary outcome was the sensitivity and specificity of the Neuropad® for the diagnosis of CAN, and secondary outcomes were the sensitivity and specificity of Neuropad® for DSP. We studied 154 patients (74 men and 80 women). Prevalence of CAN was extremely high (68.0% of study participants), but also DSP was prevalent, particularly according to the signs-based definition (45%). The sensitivity of the Neuropad® for any degree of CAN was 70.1%, being slightly higher for the deep breathing and Valsalva tests than for lying-to-standing. The specificity of the Neuropad® for any type of CAN was only 37.0%, as expected for a screening exam. The negative predictive value was higher for the deep breathing and Valsalva tests (69.4 and 81.6%, respectively). Neuropad showed also a good sensitivity and negative predictive value for DSP. The sensitivity and specificity of Neuropad were better among men, and among patients with diabetes duration above the group median. The Neuropad is a simple and inexpensive device that demonstrated an adequate performance as a screening tool for cardiovascular autonomic neuropathy in Latin American patients with DM2. Copyright © 2016 Elsevier Inc. All rights reserved.
Dos Santos, Denise Takehana; Costa e Silva, Adriana Paula Andrade; Vannier, Michael Walter; Cavalcanti, Marcelo Gusmão Paraiso
2004-12-01
The purpose of this study was to demonstrate the sensitivity and specificity of multislice computerized tomography (CT) for diagnosis of maxillofacial fractures following specific protocols using an independent workstation. The study population consisted of 56 patients with maxillofacial fractures who were submitted to a multislice CT. The original data were transferred to an independent workstation using volumetric imaging software to generate axial images and simultaneous multiplanar (MPR) and 3-dimensional (3D-CT) volume rendering reconstructed images. The images were then processed and interpreted by 2 examiners using the following protocols independently of each other: axial, MPR/axial, 3D-CT images, and the association of axial/MPR/3D images. The clinical/surgical findings were considered the gold standard corroborating the diagnosis of the fractures and their anatomic localization. The statistical analysis was carried out using validity and chi-squared tests. The association of axial/MPR/3D images indicated a higher sensitivity (range 95.8%) and specificity (range 99%) than the other methods regarding the analysis of all regions. CT imaging demonstrated high specificity and sensitivity for maxillofacial fractures. The association of axial/MPR/3D-CT images added important information in relationship to other CT protocols.
Crawley, Oliver; Barroso, Consuelo; Testori, Sarah; Ferrandiz, Nuria; Silva, Nicola; Castellano-Pozo, Maikel; Jaso-Tamame, Angel Luis; Martinez-Perez, Enrique
2016-01-01
Wapl induces cohesin dissociation from DNA throughout the mitotic cell cycle, modulating sister chromatid cohesion and higher-order chromatin structure. Cohesin complexes containing meiosis-specific kleisin subunits govern most aspects of meiotic chromosome function, but whether Wapl regulates these complexes remains unknown. We show that during C. elegans oogenesis WAPL-1 antagonizes binding of cohesin containing COH-3/4 kleisins, but not REC-8, demonstrating that sensitivity to WAPL-1 is dictated by kleisin identity. By restricting the amount of chromosome-associated COH-3/4 cohesin, WAPL-1 controls chromosome structure throughout meiotic prophase. In the absence of REC-8, WAPL-1 inhibits COH-3/4-mediated cohesion, which requires crossover-fated events formed during meiotic recombination. Thus, WAPL-1 promotes functional specialization of meiotic cohesin: WAPL-1-sensitive COH-3/4 complexes modulate higher-order chromosome structure, while WAPL-1-refractory REC-8 complexes provide stable cohesion. Surprisingly, a WAPL-1-independent mechanism removes cohesin before metaphase I. Our studies provide insight into how meiosis-specific cohesin complexes are regulated to ensure formation of euploid gametes. DOI: http://dx.doi.org/10.7554/eLife.10851.001 PMID:26841696
Smith, Klayton; Boone, Kyle; Victor, Tara; Miora, Deborah; Cottingham, Maria; Ziegler, Elizabeth; Zeller, Michelle; Wright, Matthew
2014-01-01
The purpose of this archival study was to identify performance validity tests (PVTs) and standard IQ and neurocognitive test scores, which singly or in combination, differentiate credible patients of low IQ (FSIQ ≤ 75; n = 55) from non-credible patients. We compared the credible participants against a sample of 74 non-credible patients who appeared to have been attempting to feign low intelligence specifically (FSIQ ≤ 75), as well as a larger non-credible sample (n = 383) unselected for IQ. The entire non-credible group scored significantly higher than the credible participants on measures of verbal crystallized intelligence/semantic memory and manipulation of overlearned information, while the credible group performed significantly better on many processing speed and memory tests. Additionally, credible women showed faster finger-tapping speeds than non-credible women. The credible group also scored significantly higher than the non-credible subgroup with low IQ scores on measures of attention, visual perceptual/spatial tasks, processing speed, verbal learning/list learning, and visual memory, and credible women continued to outperform non-credible women on finger tapping. When cut-offs were selected to maintain approximately 90% specificity in the credible group, sensitivity rates were highest for verbal and visual memory measures (i.e., TOMM trials 1 and 2; Warrington Words correct and time; Rey Word Recognition Test total; RAVLT Effort Equation, Trial 5, total across learning trials, short delay, recognition, and RAVLT/RO discriminant function; and Digit Symbol recognition), followed by select attentional PVT scores (i.e., b Test omissions and time to recite four digits forward). When failure rates were tabulated across seven most sensitive scores, a cut-off of ≥ 2 failures was associated with 85.4% specificity and 85.7% sensitivity, while a cut-off of ≥ 3 failures resulted in 95.1% specificity and 66.0% sensitivity. Results are discussed in light of extant literature and directions for future research.
Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.
2011-01-01
Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance. PMID:15601640
Schmidt, Dietmar; Bergeron, Christine; Denton, Karin J; Ridder, Ruediger
2011-06-25
The objective of this study was to analyze the diagnostic performance of a newly established immunocytochemical dual-stain protocol, which simultaneously detects p16(INK4a) and Ki-67 expression in cervical cytology samples, for identifying high-grade cervical intraepithelial neoplasia (CIN2+) in women with Papanicolaou (Pap) cytology results categorized as atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesions (LSIL). Residual liquid-based cytology material from 776 retrospectively collected ASCUS/LSIL cases that were available from a recent study evaluating p16 cytology and HPV testing were subjected to p16/Ki-67 dual staining. The presence of 1 or more double-immunoreactive cell(s) was regarded as a positive test outcome, irrespective of morphology. Test results were correlated to histology follow-up. Sensitivity of p16/Ki-67 dual-stain cytology for biopsy-confirmed CIN2+ was 92.2% (ASCUS) and 94.2% (LSIL), while specificity rates were 80.6% (ASCUS) and 68.0% (LSIL), respectively. Similar sensitivity/specificity profiles were found for both age groups of women aged <30 years versus women aged ≥30 years. Dual-stain cytology showed comparable sensitivity, but significantly higher specificity, when compared with human papillomavirus (HPV) testing. The results of this study show that p16/Ki-67 dual-stain cytology provided a high sensitivity for the detection of underlying CIN2+ in women with ASCUS or LSIL Pap cytology results, comparable to the rates previously reported for HPV testing and p16 single-stain cytology. However, the specificity of this morphology-independent interpretation of p16/Ki-67 dual-stain cytology testing was further improved compared with the earlier p16 single-stain cytology approach, which required morphology interpretation, and it is significantly higher when compared with HPV testing. Copyright © 2011 American Cancer Society.
Sirota, Alan D; Rohsenow, Damaris J; Dolan, Sara L; Martin, Rosemarie A; Kahler, Christopher W
2013-03-01
Intolerance of discomfort associated with recent smoking cessation has been studied with only one smoking-specific questionnaire. The present study investigates the extent to which the previously validated Intolerance for Smoking Abstinence Discomfort Questionnaire (IDQ-S) scales share variance with (a) laboratory measures of distress tolerance (Paced Serial Addition Task and a breath-holding task) that have themselves been validated against smoking history, (b) the cold pressor task (not previously validated for smoking), and (c) an anxiety sensitivity questionnaire previously used for a similar purpose. The study then tests the hypothesis that the IDQ-S scales will have a higher correlation with smoking rate and dependence and with number and length of past smoking cessation attempts than with anxiety sensitivity or behavioral distress tolerance tasks do, since those measures are not smoking-specific. Sixty daily smokers recruited from the community completed the measures. The behavioral tasks and anxiety sensitivity shared little common variance. Anxiety sensitivity correlated more highly with IDQ-S than did the behavioral tasks but only 27% of variance was shared with the IDQ-S Withdrawal Intolerance; no distress tolerance measure correlated significantly with the IDQ-S Lack of Cognitive Coping scale. Only the IDQ-S scales correlated significantly with nicotine dependence, rate and past cessation: Withdrawal Intolerance with nicotine dependence and rate, and Lack of Cognitive Coping with fewer quit attempts. The smoking-specific measure of intolerance for discomfort may be more useful in smoking research than the less specific measures of distress tolerance. Published by Elsevier Ltd.
Laserson, K F; Petralanda, I; Hamlin, D M; Almera, R; Fuentes, M; Carrasquel, A; Barker, R H
1994-02-01
We have examined the reproducibility, sensitivity, and specificity of detecting Plasmodium falciparum using the polymerase chain reaction (PCR) and the species-specific probe pPF14 under field conditions in the Venezuelan Amazon. Up to eight samples were field collected from each of 48 consenting Amerindians presenting with symptoms of malaria. Sample processing and analysis was performed at the Centro Amazonico para la Investigacion y Control de Enfermedades Tropicales Simon Bolivar. A total of 229 samples from 48 patients were analyzed by PCR methods using four different P. falciparum-specific probes. One P. vivax-specific probe and by conventional microscopy. Samples in which results from PCR and microscopy differed were reanalyzed at a higher sensitivity by microscopy. Results suggest that microscopy-negative, PCR-positive samples are true positives, and that microscopy-positive and PCR-negative samples are true negatives. The sensitivity of the DNA probe/PCR method was 78% and its specificity was 97%. The positive predictive value of the PCR method was 88%, and the negative predictive value was 95%. Through the analysis of multiple blood samples from each individual, the DNA probe/PCR methodology was found to have an inherent reproducibility that was highly statistically significant.
Bedenić, B; Boras, A
2001-01-01
The plasmid-mediated extended-spectrum beta-lactamases (ESBL) confer resistance to oxymino-cephalosporins, such as cefotaxime, ceftazidime, and ceftriaxone and to monobactams such as aztreonam. It is well known fact that ESBL producing bacteria exhibit a pronounced inoculum effect against broad spectrum cephalosporins like ceftazidime, cefotaxime, ceftriaxone and cefoperazone. The aim of this investigation was to determine the effect of inoculum size on the sensitivity and specificity of double-disk synergy test (DDST) which is the test most frequently used for detection of ESBLs, in comparison with other two methods (determination of ceftazidime MIC with and without clavulanate and inhibitor potentiated disk-diffusion test) which are seldom used in clinical laboratories. The experiments were performed on a set of K. pneumoniae strains with previously characterized beta-lactamases which comprise: 10 SHV-5 beta-lactamase producing K. pneumoniae, 20 SHV-2 + 1 SHV 2a beta-lactamase producing K. pneumoniae, 7 SHV-12 beta-lactamase producing K. pneumoniae, 39 putative SHV ESBL producing K. pneumoniae and 26 K. pneumoniae isolates highly susceptible to ceftazidime according to Kirby-Bauer disk-diffusion method and thus considered to be ESBL negative. According to the results of this investigation, increase in inoculum size affected more significantly the sensitivity of DDST than of other two methods. The sensitivity of the DDST was lower when a higher inoculum size of 10(8) CFU/ml was applied, in distinction from other two methods (MIC determination and inhibitor potentiated disk-diffusion test) which retained high sensitivity regardless of the density of bacterial suspension. On the other hand, DDST displayed higher specificity compared to other two methods regardless of the inoculum size. This investigation found that DDST is a reliable method but it is important to standardize the inoculum size.
Fang, Jian; Luan, Jiangwei; Zhu, Gaohong; Qi, Chang; Wang, Dandan
2017-09-01
The purpose of this article was to investigate whether the combination of urinary beta 2 microglobulin (urinary β 2 -MG) and procalcitonin (PCT) diagnosis could enhance the localization diagnostic precision of pediatric urinary tract infection comparing with single diagnosis. A study was conducted in the Nephrology Department of Wuhan women and children's health care centre. This study incorporated 85 participants, including 35 children who were diagnosed as upper urinary tract infection (UUTI) with the symptom of fever and 50 children who conducted lower urinary tract infection (LUTI). Levels of PCT and urinary β 2 -MG in both UUTI and LUTI patients were measured and compared. The level of PCT and β 2 -MG were both significantly higher in UUTI group compared with in LUTI group. AUC of urinary β 2 -MG ROC (sensitivity of 71.4%, specificity of 90.0%) was significantly smaller than that of PCT ROC (sensitivity of 77.1%, specificity of 96.0%) in the single diagnosis. Although in the combined diagnosis, the sensitivity and specificity increased to 88.6% and 98%, respectively. Both PCT and β 2 -MG could be used to localize the UTI. Introducing urinary β 2 -MG into PCT diagnosis could increase the sensitivity and specificity of UTI lesion diagnosis in clinical practice. © 2016 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.
Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong
2018-02-08
Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Automated detection of diabetic retinopathy lesions on ultrawidefield pseudocolour images.
Wang, Kang; Jayadev, Chaitra; Nittala, Muneeswar G; Velaga, Swetha B; Ramachandra, Chaithanya A; Bhaskaranand, Malavika; Bhat, Sandeep; Solanki, Kaushal; Sadda, SriniVas R
2018-03-01
We examined the sensitivity and specificity of an automated algorithm for detecting referral-warranted diabetic retinopathy (DR) on Optos ultrawidefield (UWF) pseudocolour images. Patients with diabetes were recruited for UWF imaging. A total of 383 subjects (754 eyes) were enrolled. Nonproliferative DR graded to be moderate or higher on the 5-level International Clinical Diabetic Retinopathy (ICDR) severity scale was considered as grounds for referral. The software automatically detected DR lesions using the previously trained classifiers and classified each image in the test set as referral-warranted or not warranted. Sensitivity, specificity and the area under the receiver operating curve (AUROC) of the algorithm were computed. The automated algorithm achieved a 91.7%/90.3% sensitivity (95% CI 90.1-93.9/80.4-89.4) with a 50.0%/53.6% specificity (95% CI 31.7-72.8/36.5-71.4) for detecting referral-warranted retinopathy at the patient/eye levels, respectively; the AUROC was 0.873/0.851 (95% CI 0.819-0.922/0.804-0.894). Diabetic retinopathy (DR) lesions were detected from Optos pseudocolour UWF images using an automated algorithm. Images were classified as referral-warranted DR with a high degree of sensitivity and moderate specificity. Automated analysis of UWF images could be of value in DR screening programmes and could allow for more complete and accurate disease staging. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Magnetic Resonance Imaging for Patellofemoral Chondromalacia: Is There a Role for T2 Mapping?
van Eck, Carola F; Kingston, R Scott; Crues, John V; Kharrazi, F Daniel
2017-11-01
Patellofemoral pain is common, and treatment is guided by the presence and grade of chondromalacia. To evaluate and compare the sensitivity and specificity in detecting and grading chondral abnormalities of the patella between proton density fat suppression (PDFS) and T2 mapping magnetic resonance imaging (MRI). Cohort study; Level of evidence, 2. A total of 25 patients who underwent MRI of the knee with both a PDFS sequence and T2 mapping and subsequently underwent arthroscopic knee surgery were included. The cartilage surface of the patella was graded on both MRI sequences by 2 independent, blinded radiologists. Cartilage was then graded during arthroscopic surgery by a sports medicine fellowship-trained orthopaedic surgeon. Reliability, sensitivity, specificity, and accuracy were determined for both MRI methods. The findings during arthroscopic surgery were considered the gold standard. Intraobserver and interobserver agreement for both PDFS (98.5% and 89.4%, respectively) and T2 mapping (99.4% and 91.3%, respectively) MRI were excellent. For T2 mapping, the sensitivity (61%) and specificity (64%) were comparable, whereas for PDFS there was a lower sensitivity (37%) but higher specificity (81%) in identifying cartilage abnormalities. This resulted in a similar accuracy for PDFS (59%) and T2 mapping (62%). Both PDFS and T2 mapping MRI were reliable but only moderately accurate in predicting patellar chondromalacia found during knee arthroscopic surgery.
Broll, Matthias; Albrecht, Katinka; Tarner, Ingo; Müller-Ladner, Ulf; Strunk, Johannes
2012-01-01
To evaluate the value of grey-scale ultrasonography (US) including power Doppler ultrasonography (PDUS) and low-field magnetic resonance imaging (MRI) for the diagnosis of arthritis in a diagnostic phase III study. Fifty consecutive patients with suspected arthritis were included in the study. Following a standardised protocol, US of the carpus and the metacarpophalangeal (MCP) joints of the dominant hand was performed. Subsequently, low-field MRI was done using standard sequences, with contrast agent (Gadolinium DTPA) administered to 29 patients. In 32 out of 50 patients a clinical diagnosis of arthritis was established. In grey-scale ultrasonography including PDUS, sensitivity and specificity were determined as 0.94 and 0.5, respectively, for synovitis (effusion and hypertrophy), 0.72 and 0.94, respectively, for Doppler signals, and 0.38 and 1.0, respectively, for bone erosions. In low-field MRI, sensitivity and specificity values were 0.77 and 0.75, respectively, for synovitis (when using contrast agent), 0.48 and 0.78, respectively, for bone marrow oedema, and 0.58 and 0.83, respectively, for bone erosion. Both grey-scale ultrasonography including PDUS and low-field MRI are suitable imaging methods for diagnosing arthritis at an early stage. However, PDUS displays a higher specificity and almost the same sensitivity as compared to contrast-enhanced MRI, while being a much simpler and less costly procedure.
Use of shear wave elastography to differentiate benign and malignant breast lesions
Olgun, Deniz Çebi; Korkmazer, Bora; Kılıç, Fahrettin; Dikici, Atilla Süleyman; Velidedeoğlu, Mehmet; Aydoğan, Fatih; Kantarcı, Fatih; Yılmaz, Mehmet Halit
2014-01-01
PURPOSE We aimed to determine the correlations between the elasticity values of solid breast masses and histopathological findings to define cutoff elasticity values differentiating malignant from benign lesions. MATERIALS and METHODS A total of 115 solid breast lesions of 109 consecutive patients were evaluated prospectively using shear wave elastography (SWE). Two orthogonal elastographic images of each lesion were obtained. Minimum, mean, and maximum elasticity values were calculated in regions of interest placed over the stiffest areas on the two images; we also calculated mass/fat elasticity ratios. Correlation of elastographic measurements with histopathological results were studied. RESULTS Eighty-three benign and thirty-two malignant lesions were histopathologically diagnosed. The minimum, mean, and maximum elasticity values, and the mass/fat elasticity ratios of malignant lesions, were significantly higher than those of benign lesions. The cutoff value was 45.7 kPa for mean elasticity (sensitivity, 96%; specificity, 95%), 54.3 kPa for maximum elasticity (sensitivity, 95%; specificity, 94%), 37.1 kPa for minimum elasticity (sensitivity, 96%; specificity, 95%), and 4.6 for the mass/fat elasticity ratio (sensitivity, 97%; specificity, 95%). CONCLUSION SWE yields additional valuable quantitative data to ultrasonographic examination on solid breast lesions. SWE may serve as a complementary tool for diagnosis of breast lesions. Long-term clinical studies are required to accurately select lesions requiring biopsy. PMID:24509183
Liu, Xinfeng; Guan, Yuyao; Cheng, Shiliang; Huang, Yidan; Yan, Qin; Zhang, Jun; Huang, Guanjun; Zheng, Jian; Liu, Tianqiang
2016-12-01
Vibrio parahaemolyticus is widely present in brackish water all over the world, causing infections in certain aquatic animals. It is also a foodborne pathogen that causes diarrhea in humans. The aim of this study is to develop an immunochromatographic lateral flow assay (LFA) for rapid detection of V. parahaemolyticus in both aquatic products and human feces of diarrheal patients. Two monoclonal antibody (MAb) pairs, GA1a-IC9 and IC9-KB4c, were developed and proven to be highly specific and sensitive to V. parahaemolyticus. Based on the two MAb pairs, two types of LFA strips were prepared. Their testing limits for V. parahaemolyticus culture were both 1.2×10 3 CFU/ml. The diagnostic sensitivities and specificities were both 100% for the 32 tested microbial species, including 6 Vibrio species. Subsequently, the LFA strips were used to test Whiteleg shrimps and human feces. The type II strip showed a higher diagnostic sensitivity. Its sensitivity and specificity for hepatopancreas and fecal samples from 13 Whiteleg shrimps and fecal samples from 146 human diarrheal patients were all 100%. In conclusion, our homemade type II LFA is a very promising testing device for rapid and convenient detection of V. parahaemolyticus infection not only in aquatic animals, but also in human diarrheal patients. This sensitive immunochromtographic LFA allows rapid detection of V. parahaemolyticus without requirement of culture enrichment. Copyright © 2016. Published by Elsevier B.V.
Four human Plasmodium species quantification using droplet digital PCR.
Srisutham, Suttipat; Saralamba, Naowarat; Malleret, Benoit; Rénia, Laurent; Dondorp, Arjen M; Imwong, Mallika
2017-01-01
Droplet digital polymerase chain reaction (ddPCR) is a partial PCR based on water-oil emulsion droplet technology. It is a highly sensitive method for detecting and delineating minor alleles from complex backgrounds and provides absolute quantification of DNA targets. The ddPCR technology has been applied for detection of many pathogens. Here the sensitive assay utilizing ddPCR for detection and quantification of Plasmodium species was investigated. The assay was developed for two levels of detection, genus specific for all Plasmodium species and for specific Plasmodium species detection. The ddPCR assay was developed based on primers and probes specific to the Plasmodium genus 18S rRNA gene. Using ddPCR for ultra-sensitive P. falciparum assessment, the lower level of detection from concentrated DNA obtained from a high volume (1 mL) blood sample was 11 parasites/mL. For species identification, in particular for samples with mixed infections, a duplex reaction was developed for detection and quantification P. falciparum/ P. vivax and P. malariae/ P. ovale. Amplification of each Plasmodium species in the duplex reaction showed equal sensitivity to singleplex single species detection. The duplex ddPCR assay had higher sensitivity to identify minor species in 32 subpatent parasitaemia samples from Cambodia, and performed better than real-time PCR. The ddPCR assay shows high sensitivity to assess very low parasitaemia of all human Plasmodium species. This provides a useful research tool for studying the role of the asymptomatic parasite reservoir for transmission in regions aiming for malaria elimination.
Ren, Guo-Ping; Yan, Jia-Qing; Yu, Zhi-Xin; Wang, Dan; Li, Xiao-Nan; Mei, Shan-Shan; Dai, Jin-Dong; Li, Xiao-Li; Li, Yun-Lin; Wang, Xiao-Fei; Yang, Xiao-Feng
2018-02-01
High frequency oscillations (HFOs) are considered as biomarker for epileptogenicity. Reliable automation of HFOs detection is necessary for rapid and objective analysis, and is determined by accurate computation of the baseline. Although most existing automated detectors measure baseline accurately in channels with rare HFOs, they lose accuracy in channels with frequent HFOs. Here, we proposed a novel algorithm using the maximum distributed peak points method to improve baseline determination accuracy in channels with wide HFOs activity ranges and calculate a dynamic baseline. Interictal ripples (80-200[Formula: see text]Hz), fast ripples (FRs, 200-500[Formula: see text]Hz) and baselines in intracerebral EEGs from seven patients with intractable epilepsy were identified by experienced reviewers and by our computer-automated program, and the results were compared. We also compared the performance of our detector to four well-known detectors integrated in RIPPLELAB. The sensitivity and specificity of our detector were, respectively, 71% and 75% for ripples and 66% and 84% for FRs. Spearman's rank correlation coefficient comparing automated and manual detection was [Formula: see text] for ripples and [Formula: see text] for FRs ([Formula: see text]). In comparison to other detectors, our detector had a relatively higher sensitivity and specificity. In conclusion, our automated detector is able to accurately calculate a dynamic iEEG baseline in different HFO activity channels using the maximum distributed peak points method, resulting in higher sensitivity and specificity than other available HFO detectors.
Korevaar, Daniël A.; Cohen, Jérémie F.; Spijker, René; Saldanha, Ian J.; Dickersin, Kay; Virgili, Gianni; Hooft, Lotty; Bossuyt, Patrick M.M.
2016-01-01
Objective To assess whether conference abstracts that report higher estimates of diagnostic accuracy are more likely to reach full-text publication in a peer-reviewed journal. Study Design and Setting We identified abstracts describing diagnostic accuracy studies, presented between 2007 and 2010 at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting. We extracted reported estimates of sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and diagnostic odds ratio (DOR). Between May and July 2015, we searched MEDLINE and EMBASE to identify corresponding full-text publications; if needed, we contacted abstract authors. Cox regression was performed to estimate associations with full-text publication, where sensitivity, specificity, and AUC were logit transformed, and DOR was log transformed. Results A full-text publication was found for 226/399 (57%) included abstracts. There was no association between reported estimates of sensitivity and full-text publication (hazard ratio [HR] 1.09 [95% confidence interval {CI} 0.98, 1.22]). The same applied to specificity (HR 1.00 [95% CI 0.88, 1.14]), AUC (HR 0.91 [95% CI 0.75, 1.09]), and DOR (HR 1.01 [95% CI 0.94, 1.09]). Conclusion Almost half of the ARVO conference abstracts describing diagnostic accuracy studies did not reach full-text publication. Studies in abstracts that mentioned higher accuracy estimates were not more likely to be reported in a full-text publication. PMID:27312228
Yang, Qing-Li; Shen, Ji-Qing; Jiang, Zhi-Hua; Yang, Yi-Chao; Li, Hong-Mei; Chen, Ying-Dan; Zhou, Xiao-Nong
2014-06-01
To identify Clonorchis sinensis metacercariae using PCR targeting ribosomal DNA ITS region and COX1 gene. Pseudorasbora parva were collected from Hengxian County of Guangxi at the end of May 2013. Single metacercaria of C. sinensis and other trematodes were separated from muscle tissue of P. parva by digestion method. Primers targeting ribosomal DNA ITS region and COX1 gene of C. sinensis were designed for PCR and the universal primers were used as control. The sensitivity and specificity of the PCR detection were analyzed. C. sinensis metacercariae at different stages were identified by PCR. DNA from single C. sinensis metacercaria was detected by PCR targeting ribosomal DNA ITS region and COX1 gene. The specific amplicans have sizes of 437/549, 156/249 and 195/166 bp, respectively. The ratio of the two positive numbers in PCR with universal primers and specific primers targeting C. sinensis ribosomal DNA ITS1 and ITS2 regions was 0.905 and 0.952, respectively. The target gene fragments were amplified by PCR using COX1 gene-specific primers. The PCR with specific primers did not show any non-specific amplification. However, the PCR with universal primers targeting ribosomal DNA ITS regions performed serious non-specific amplification. C. sinensis metacercariae at different stages are identified by morphological observation and PCR method. Species-specific primers targeting ribosomal DNA ITS region show higher sensitivity and specificity than the universal primers. PCR targeting COX1 gene shows similar sensitivity and specificity to PCR with specific primers targeting ribosomal DNA ITS regions.
Kelleher, Maureen E; Puchalski, Sarah M; Drake, Christiana; le Jeune, Sarah S
2014-07-01
To evaluate the sensitivity and specificity of direct digital abdominal radiography for the diagnosis of enterolithiasis in equids and to assess the effect of the number and anatomic location of enteroliths and gas distention of the gastrointestinal tract on diagnostic sensitivity of the technique. Retrospective case series. 238 horses and ponies ≥ 1 year old that underwent digital abdominal radiography with subsequent exploratory celiotomy or postmortem examination. For each case, 3 reviewers independently evaluated radiographic views. Radiographic images were evaluated for presence or absence and location of enteroliths and the degree of gas distention. Signalment, definitive diagnosis based on exploratory celiotomy or postmortem examination findings, and number and anatomic location of enteroliths were obtained from the medical records. 70 of the 238 (29.4%) equids had confirmed enterolithiasis. With regard to diagnosis of enterolithiasis via digital radiography, overall sensitivity and specificity for the 3 reviewers were 84% and 96%, respectively. Sensitivity was lower for small colon enteroliths (61.5%) than for large colon enteroliths (88.9%) and was negatively affected by gas distention of the gastrointestinal tract. Sensitivity was not affected by the number of enteroliths. Sensitivity and specificity of digital radiography for the diagnosis of large colon enterolithiasis in equids was high. Sensitivity of digital radiography for detection of small colon enteroliths was lower than that for large colon enteroliths, but was higher than that typically associated with computed radiography. In geographic regions in which enterolithiasis in equids is endemic, digital abdominal radiography could be used as a diagnostic test for equids with colic.
Just, Jocelyne; Deslandes-Boutmy, Emmanuelle; Amat, Flore; Desseaux, Kristell; Nemni, Ariane; Bourrat, Emmanuelle; Sahraoui, Fatia; Pansé, Isabelle; Bagot, Martine; Fouéré, Sébastien
2014-11-01
Early-onset atopic dermatitis (AD) is a particular phenotype that may convey a risk of developing multiple sensitizations to allergens but little is known about the pathway of sensitization. The aims of this study were to describe the natural history of sensitization to allergens for this phenotype and to identify the most predictive marker associated with the risk of developing sensitization to inhaled allergens in a well-selected cohort of infants with AD. Infants with active AD were enrolled and prospectively explored for biological markers of atopy every year until the age of 6 yr. Allergic sensitization was defined as the presence of positive specific IgEs to allergens and multiple sensitizations as being sensitized to ≥2 allergens. Elevated blood eosinophilia was defined as an eosinophil blood count ≥470 eosinophils/mm(3) and elevated total IgE as a serum IgE level ≥45 kU/l. Two hundred and twenty-nine infants were included. Elevated blood eosinophilia was observed at baseline in 60 children (26.2%) and elevated total IgE in 85 (37.1%). When elevated at baseline, eosinophilia and IgE levels remained significantly higher during the follow-up period. Sensitization to food allergens decreased from 58% to 34%, whereas sensitization to inhaled allergens increased over time from 17% to 67%. Initial multiple sensitizations to food allergens were the most predictive factor for the risk of developing sensitization to inhaled allergens at 6 yr (OR 3.72 [1.68-8.30] p < 0.001). In the early-onset AD phenotype, multiple sensitization to food allergens conveys a higher risk of sensitization to inhaled allergens than single sensitization. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Camelo-Piragua, Sandra; Jansen, Michael; Ganguly, Aniruddha; Kim, J. ChulMin; Cosper, Arjola K.; Dias-Santagata, Dora; Nutt, Catherine L.; Iafrate, A. John; Louis, David N.
2011-01-01
One of the major challenges of surgical neuropathology is the distinction of diffuse astrocytoma (World Health Organization [WHO] grade II) from astrocytosis. The most commonly used ancillary tool to solve this problem is p53 immunohistochemistry (IHC), but this is neither sensitive nor specific. Isocitrate dehydrogenase 1 (IDH1) mutations are common in lower grade gliomas, with most causing a specific amino acid change (R132H) that can be detected with a monoclonal antibody. IDH2 mutations are rare, but also occur in gliomas. In addition, gains of chromosome 7 are common in gliomas. In this study we assessed the status of p53, IDH1/2 and chromosome 7 to determine the most useful panel to distinguish astrocytoma from astrocytosis. We studied biopsy specimens from 21 WHO grade II diffuse astrocytomas and 20 reactive conditions. The single most sensitive test to identify astrocytoma is fluorescence in situ hybridization (FISH) for chromosome 7 gain (76.2%). The combination of p53 and mutant IDH1 IHC provides a higher sensitivity (71.4%) than either test alone (47.8%); this combination offers a practical initial approach for the surgical pathologist. The best overall sensitivity (95%) is achieved when FISH for chromosome 7 gain is added to the p53-mutant IDH1 IHC panel. PMID:21343879
2014-03-01
Behçet's disease (BD) is a chronic, relapsing, inflammatory vascular disease with no pathognomonic test. Low sensitivity of the currently applied International Study Group (ISG) clinical diagnostic criteria led to their reassessment. An International Team for the Revision of the International Criteria for BD (from 27 countries) submitted data from 2556 clinically diagnosed BD patients and 1163 controls with BD-mimicking diseases or presenting at least one major BD sign. These were randomly divided into training and validation sets. Logistic regression, 'leave-one-country-out' cross-validation and clinical judgement were employed to develop new International Criteria for BD (ICBD) with the training data. Existing and new criteria were tested for their performance in the validation set. For the ICBD, ocular lesions, oral aphthosis and genital aphthosis are each assigned 2 points, while skin lesions, central nervous system involvement and vascular manifestations 1 point each. The pathergy test, when used, was assigned 1 point. A patient scoring ≥4 points is classified as having BD. In the training set, 93.9% sensitivity and 92.1% specificity were assessed compared with 81.2% sensitivity and 95.9% specificity for the ISG criteria. In the validation set, ICBD demonstrated an unbiased estimate of sensitivity of 94.8% (95% CI: 93.4-95.9%), considerably higher than that of the ISG criteria (85.0%). Specificity (90.5%, 95% CI: 87.9-92.8%) was lower than that of the ISG-criteria (96.0%), yet still reasonably high. For countries with at least 90%-of-cases and controls having a pathergy test, adding 1 point for pathergy test increased the estimate of sensitivity from 95.5% to 98.5%, while barely reducing specificity from 92.1% to 91.6%. The new proposed criteria derived from multinational data exhibits much improved sensitivity over the ISG criteria while maintaining reasonable specificity. It is proposed that the ICBD criteria to be adopted both as a guide for diagnosis and classification of BD. © 2013 The Authors Journal of the European Academy of Dermatology and Venereology © 2013 European Academy of Dermatology and Venereology.
Furuya, Kazuhiro; Kawahara, Takashi; Narahara, Masaki; Tokita, Takashi; Fukui, Sachi; Imano, Masashi; Mitome, Taku; Ito, Yusuke; Izumi, Koji; Osaka, Kimito; Yokomizo, Yumiko; Hayashi, Narihiko; Hasumi, Hisashi; Nawata, Shintaro; Kawano, Tsuyoshi; Yao, Masahiro; Uemura, Hiroji
2017-08-01
More accurate diagnostic procedures for prostate cancer are needed to avoid unnecessary biopsy due to the low specificity of prostate-specific antigen (PSA). Recent studies showed that the percentage of serum isoform [-2]proPSA (p2PSA) to free PSA (%p2PSA), the Prostate Health Index (PHI) and magnetic resonance imaging (MRI) were more accurate than PSA. The aim of this study was to test the accuracy of %p2PSA, PHI and MRI in discriminating patients with and without prostate cancer. The subjects were 50 consecutive men with a PSA level of 2.0-10.0 ng/ml, who underwent prostate biopsy from October 2012 to July 2014. These patients underwent multiparametric MRI before biopsy, and their serum samples were measured for PSA, free PSA and p2PSA. The sensitivity, specificity and accuracy of PHI, %p2PSA and MRI were compared with PSA in the diagnosis of biopsy-confirmed prostate cancer. In a univariate analysis, %p2PSA [area under the curve (AUC): 0.811] and PHI (AUC 0.795) were more accurate than MRI (AUC: 0.583) and PSA (AUC: 0.554) for prostate cancer detection. At 60% sensitivity, the specificity of PHI (76.5%) was higher than that of MRI (52.9%). For significant cancer detection, %p2PSA (AUC: 0.745), PHI (AUC: 0.791) and MRI (AUC: 0.739) were marginally more accurate than PSA (AUC: 0.696). At 85% sensitivity, the specificity of MRI (62.1%) was higher than that of PHI (34.5%). PHI and %p2PSA can be used for screening the general population and MRI can be used for detection of significant cancer in patients suspected, from screening tests, of having prostate cancer.
Enciso, Reyes; Clark, Glenn T
2011-01-01
The aim of this study was to compare the sensitivity and specificity of two questionnaires to identify patients with obstructive sleep apnea (OSA). Fifty-three moderate to severe OSA patients [with a respiratory disturbance index (RDI) ≥ 15] and 31 controls (RDI < 15) based on ambulatory somnographic assessment were recruited through flyers and mail at USC School of Dentistry. Each patient answered the Berlin and apnea risk evaluation system (ARES) questionnaires. The responses to the questionnaires were scored and compared for significant group differences. Moderate and severe OSA patients were predominantly male, older, had a larger neck size, and larger body mass index than controls. There were no significant differences in race or ethnicity between the two groups. In this study, subjects having a "high risk" ARES questionnaire were 7.9 times as likely to have OSA as subjects with "low or no risk" score (p = 0.0002). The ARES questionnaire had a sensitivity of 90.6%, specificity of 43.2%, a positive predictive value (PPV) of 73.8%, and negative predictive value (NPV) of 73.7% compared to 67.9%, 54.8%, 72%, and 50%, respectively, for the Berlin questionnaire using a cut point of RDI ≥ 15. In this specific patient group, not uncommon to the regular dental private practice, the ARES questionnaire performed better than the Berlin questionnaire with higher sensitivity, similar PPV, higher NPV, but lower specificity. The lower specificity could be explained in part because the ARES has been tailored to screen patients with an RDI ≥ 5, and our study included mostly mild to severe patients. In conclusion, in this specific group of subjects, the ARES questionnaire is a better choice than the Berlin questionnaire; however, the Berlin questionnaire is publicly available and the ARES screener is proprietary.
Yonekura, Syuji; Okamoto, Yoshitaka; Nakayama, Satoshi
Japanese cypress pollen is a major causative allergen of seasonal allergic rhinitis in Japan. Although ImmunoCAP-specific immunoglobulin E (IgE) reagent Japanese cypress pollen has been widely used as a diagnostic aid, its sensitivity requires enhancement. This study evaluated an improved version of this reagent. Serum samples from 61 subjects who underwent Japanese cypress pollen exposure testing in an environmental challenge chamber in Chiba University were assessed using the conventional ImmunoCAPspecific IgE Japanese cypress pollen product and the improved product. In addition, specific IgE for Cha o 1 and Cha o 2, the primary allergen components of Japanese cypress pollen, was evaluated and their reactivity to specific IgE was compared between the conventional and improved products. The antibody titer of the improved product was approximately 1.8-fold that of the conventional product. In addition, higher correlations with Cha o 1 and Cha o 2 were observed for the improved product than for the conventional product. The clinical sensitivity (≥class 2) in 56 exposure test-positive subjects was better for the improved product (80.4%) than for the conventional product (71.4%). An improvement of the ImmunoCAP-specific IgE reagent Japanese cypress pollen resulted in enhanced Japanese cypress pollen-specific IgE sensitivity. The primary reason for this appeared to be an improved Cha o 1- and Cha o 2-specific IgE detectability.
Turfus, Sophie C; Vo, Tu; Niehaus, Nadia; Gerostamoulos, Dimitri; Beyer, Jochen
2013-06-01
A commercial enzyme immunoassay for the qualitative and semi-quantitative measurement of ethyl glucuronide (EtG) in urine was evaluated. Post-mortem (n=800), and clinical urine (n=200) samples were assayed using a Hitachi 902 analyzer. The determined concentrations were compared with those obtained using a previously published liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of EtG and ethyl sulfate. Using a cut-off of 0.5 µg/ml and LC-MS/MS limit of reporting of 0.1 µg/ml, there was a sensitivity of 60.8% and a specificity of 100% for clinical samples. For post-mortem samples, sensitivity and specificity were 82.4% and 97.1%, respectively. When reducing the cut-off to 0.1 µg/ml, the sensitivity and specificity were 83.3% and 100% for clinical samples whereas for post-mortem samples the sensitivity and specificity were 90.3 % and 88.3 %, respectively. The best trade-offs between sensitivity and specificity for LC-MS/MS limits of reporting of 0.5 and 0.1 µg/ml were achieved when using immunoassay cut-offs of 0.3 and 0.092 µg/ml, respectively. There was good correlation between quantitative results obtained by both methods but analysis of samples by LC-MS/MS gave higher concentrations than by enzyme immunoassay (EIA), with a statistically significant proportional bias (P<0.0001, Deming regression) for both sample types. The immunoassay is reliable for the qualitative and semi-quantitative presumptive detection of ethyl glucuronide in urine. Copyright © 2012 John Wiley & Sons, Ltd.
Okasha, Hussein; Elkholy, Shaimaa; El-Sayed, Ramy; Wifi, Mohamed-Naguib; El-Nady, Mohamed; El-Nabawi, Walid; El-Dayem, Waleed A; Radwan, Mohamed I; Farag, Ali; El-Sherif, Yahya; Al-Gemeie, Emad; Salman, Ahmed; El-Sherbiny, Mohamed; El-Mazny, Ahmed; Mahdy, Reem E
2017-08-28
To evaluate the accuracy of the elastography score combined to the strain ratio in the diagnosis of solid pancreatic lesions (SPL). A total of 172 patients with SPL identified by endoscopic ultrasound were enrolled in the study to evaluate the efficacy of elastography and strain ratio in differentiating malignant from benign lesions. The semi quantitative score of elastography was represented by the strain ratio method. Two areas were selected, area (A) representing the region of interest and area (B) representing the normal area. Area (B) was then divided by area (A). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by comparing diagnoses made by elastography, strain ratio and final diagnoses. SPL were shown to be benign in 49 patients and malignant in 123 patients. Elastography alone had a sensitivity of 99%, a specificity of 63%, and an accuracy of 88%, a PPV of 87% and an NPV of 96%. The best cut-off level of strain ratio to obtain the maximal area under the curve was 7.8 with a sensitivity of 92%, specificity of 77%, PPV of 91%, NPV of 80% and an accuracy of 88%. Another estimated cut off strain ratio level of 3.8 had a higher sensitivity of 99% and NPV of 96%, but with less specificity, PPV and accuracy 53%, 84% and 86%, respectively. Adding both elastography to strain ratio resulted in a sensitivity of 98%, specificity of 77%, PPV of 91%, NPV of 95% and accuracy of 92% for the diagnosis of SPL. Combining elastography to strain ratio increases the accuracy of the differentiation of benign from malignant SPL.
Okasha, Hussein; Elkholy, Shaimaa; El-Sayed, Ramy; Wifi, Mohamed-Naguib; El-Nady, Mohamed; El-Nabawi, Walid; El-Dayem, Waleed A; Radwan, Mohamed I; Farag, Ali; El-sherif, Yahya; Al-Gemeie, Emad; Salman, Ahmed; El-Sherbiny, Mohamed; El-Mazny, Ahmed; Mahdy, Reem E
2017-01-01
AIM To evaluate the accuracy of the elastography score combined to the strain ratio in the diagnosis of solid pancreatic lesions (SPL). METHODS A total of 172 patients with SPL identified by endoscopic ultrasound were enrolled in the study to evaluate the efficacy of elastography and strain ratio in differentiating malignant from benign lesions. The semi quantitative score of elastography was represented by the strain ratio method. Two areas were selected, area (A) representing the region of interest and area (B) representing the normal area. Area (B) was then divided by area (A). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by comparing diagnoses made by elastography, strain ratio and final diagnoses. RESULTS SPL were shown to be benign in 49 patients and malignant in 123 patients. Elastography alone had a sensitivity of 99%, a specificity of 63%, and an accuracy of 88%, a PPV of 87% and an NPV of 96%. The best cut-off level of strain ratio to obtain the maximal area under the curve was 7.8 with a sensitivity of 92%, specificity of 77%, PPV of 91%, NPV of 80% and an accuracy of 88%. Another estimated cut off strain ratio level of 3.8 had a higher sensitivity of 99% and NPV of 96%, but with less specificity, PPV and accuracy 53%, 84% and 86%, respectively. Adding both elastography to strain ratio resulted in a sensitivity of 98%, specificity of 77%, PPV of 91%, NPV of 95% and accuracy of 92% for the diagnosis of SPL. CONCLUSION Combining elastography to strain ratio increases the accuracy of the differentiation of benign from malignant SPL. PMID:28932088
2017-01-01
Objective To compare swallowing function between healthy subjects and patients with pharyngeal dysphagia using high resolution manometry (HRM) and to evaluate the usefulness of HRM for detecting pharyngeal dysphagia. Methods Seventy-five patients with dysphagia and 28 healthy subjects were included in this study. Diagnosis of dysphagia was confirmed by a videofluoroscopy. HRM was performed to measure pressure and timing information at the velopharynx (VP), tongue base (TB), and upper esophageal sphincter (UES). HRM parameters were compared between dysphagia and healthy groups. Optimal threshold values of significant HRM parameters for dysphagia were determined. Results VP maximal pressure, TB maximal pressure, UES relaxation duration, and UES resting pressure were lower in the dysphagia group than those in healthy group. UES minimal pressure was higher in dysphagia group than in the healthy group. Receiver operating characteristic (ROC) analyses were conducted to validate optimal threshold values for significant HRM parameters to identify patients with pharyngeal dysphagia. With maximal VP pressure at a threshold value of 144.0 mmHg, dysphagia was identified with 96.4% sensitivity and 74.7% specificity. With maximal TB pressure at a threshold value of 158.0 mmHg, dysphagia was identified with 96.4% sensitivity and 77.3% specificity. At a threshold value of 2.0 mmHg for UES minimal pressure, dysphagia was diagnosed at 74.7% sensitivity and 60.7% specificity. Lastly, UES relaxation duration of <0.58 seconds had 85.7% sensitivity and 65.3% specificity, and UES resting pressure of <75.0 mmHg had 89.3% sensitivity and 90.7% specificity for identifying dysphagia. Conclusion We present evidence that HRM could be a useful evaluation tool for detecting pharyngeal dysphagia. PMID:29201816
Park, Chul-Hyun; Kim, Don-Kyu; Lee, Yong-Taek; Yi, Youbin; Lee, Jung-Sang; Kim, Kunwoo; Park, Jung Ho; Yoon, Kyung Jae
2017-10-01
To compare swallowing function between healthy subjects and patients with pharyngeal dysphagia using high resolution manometry (HRM) and to evaluate the usefulness of HRM for detecting pharyngeal dysphagia. Seventy-five patients with dysphagia and 28 healthy subjects were included in this study. Diagnosis of dysphagia was confirmed by a videofluoroscopy. HRM was performed to measure pressure and timing information at the velopharynx (VP), tongue base (TB), and upper esophageal sphincter (UES). HRM parameters were compared between dysphagia and healthy groups. Optimal threshold values of significant HRM parameters for dysphagia were determined. VP maximal pressure, TB maximal pressure, UES relaxation duration, and UES resting pressure were lower in the dysphagia group than those in healthy group. UES minimal pressure was higher in dysphagia group than in the healthy group. Receiver operating characteristic (ROC) analyses were conducted to validate optimal threshold values for significant HRM parameters to identify patients with pharyngeal dysphagia. With maximal VP pressure at a threshold value of 144.0 mmHg, dysphagia was identified with 96.4% sensitivity and 74.7% specificity. With maximal TB pressure at a threshold value of 158.0 mmHg, dysphagia was identified with 96.4% sensitivity and 77.3% specificity. At a threshold value of 2.0 mmHg for UES minimal pressure, dysphagia was diagnosed at 74.7% sensitivity and 60.7% specificity. Lastly, UES relaxation duration of <0.58 seconds had 85.7% sensitivity and 65.3% specificity, and UES resting pressure of <75.0 mmHg had 89.3% sensitivity and 90.7% specificity for identifying dysphagia. We present evidence that HRM could be a useful evaluation tool for detecting pharyngeal dysphagia.
Preoperative identification of a suspicious adnexal mass: a systematic review and meta-analysis.
Dodge, Jason E; Covens, Allan L; Lacchetti, Christina; Elit, Laurie M; Le, Tien; Devries-Aboud, Michaela; Fung-Kee-Fung, Michael
2012-07-01
To systematically review the existing literature in order to determine the optimal strategy for preoperative identification of the adnexal mass suspicious for ovarian cancer. A review of all systematic reviews and guidelines published between 1999 and 2009 was conducted as a first step. After the identification of a 2004 AHRQ systematic review on the topic, searches of MEDLINE for studies published since 2004 was also conducted to update and supplement the evidentiary base. A bivariate, random-effects meta-regression model was used to produce summary estimates of sensitivity and specificity and to plot summary ROC curves with 95% confidence regions. Four meta-analyses and 53 primary studies were included in this review. The diagnostic performance of each technology was compared and contrasted based on the summary data on sensitivity and specificity obtained from the meta-analysis. Results suggest that 3D ultrasonography has both a higher sensitivity and specificity when compared to 2D ultrasound. Established morphological scoring systems also performed with respectable sensitivity and specificity, each with equivalent diagnostic competence. Explicit scoring systems did not perform as well as other diagnostic testing methods. Assessment of an adnexal mass by colour Doppler technology was neither as sensitive nor as specific as simple ultrasonography. Of the three imaging modalities considered, MRI appeared to perform the best, although results were not statistically different from CT. PET did not perform as well as either MRI or CT. The measurement of the CA-125 tumour marker appears to be less reliable than do other available assessment methods. The best available evidence was collected and included in this rigorous systematic review and meta-analysis. The abundant evidentiary base provided the context and direction for the diagnosis of early-staged ovarian cancer. Copyright © 2012 Elsevier Inc. All rights reserved.
Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L
2017-02-01
To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.
Wang, Xuan; Yin, Fenggui; Bi, Yuhai; Cheng, Gong; Li, Jing; Hou, Lidan; Li, Yunlong; Yang, Baozhi; Liu, Wenjun; Yang, Limin
2016-12-01
Zika virus (ZIKV) is an arbovirus that recently emerged and has expanded worldwide, causing a global threat and raising international concerns. Current molecular diagnostics, e.g., real-time PCR and reverse transcription PCR (RT-PCR), are time consuming, expensive, and can only be deployed in a laboratory instead of for field diagnostics. This study aimed to develop a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform showing sensitivity, specificity, and more convenience than previous methods, being easily distributed and implemented. Specific primers were designed and screened to target the entire ZIKV genome. The analytical sensitivity and specificity of the assay were evaluated and compared with traditional PCR and quantitative real-time PCR. Three different simulated clinical sample quick preparation protocols were evaluated to establish a rapid and straightforward treatment procedure for clinical specimens in open field detection. The RT-LAMP assay for detection of ZIKV demonstrated superior specificity and sensitivity compared to traditional PCR at the optimum reaction temperature. For the ZIKV RNA standard, the limit of detection was 20 copies/test. For the simulated ZIKV clinical samples, the limit of detection was 0.02 pfu/test, which was one order of magnitude higher than RT-PCR and similar to real-time PCR. The detection limit of simulated ZIKV specimens prepared using a protease quick processing method was consistent with that of samples prepared using commercial nucleic acid extraction kits, indicating that our ZIKV detection method could be used in point-of-care testing. The RT-LAMP assay had excellent sensitivity and specificity for detecting ZIKV and can be deployed together with a rapid specimen processing method, offering the possibility for ZIKV diagnosis outside of the laboratory. Copyright © 2016 Elsevier B.V. All rights reserved.
Kheirkhah, Ahmad; Syed, Zeba A; Satitpitakul, Vannarut; Goyal, Sunali; Müller, Rodrigo; Tu, Elmer Y; Dana, Reza
2017-07-01
To determine sensitivity and specificity of laser-scanning in vivo confocal microscopy (LS-IVCM) for detection of filamentous fungi in patients with microbial keratitis and to evaluate the effect of observer's imaging experience on these parameters. Retrospective reliability study. This study included 21 patients with filamentous fungal keratitis and 24 patients with bacterial keratitis (as controls). The etiology of infection was confirmed based on the response to specific therapy regardless of culture results. All patients had undergone full-thickness corneal imaging by a LS-IVCM (Heidelberg Retina Tomograph 3 with Rostock Cornea Module; Heidelberg Engineering, Heidelberg, Germany). The images were evaluated for the presence of fungal filaments by 2 experienced observers and 2 inexperienced observers. All observers were masked to the clinical and microbiologic data. The mean number of images obtained per eye was 917 ± 353. The average sensitivity of LS-IVCM for detecting fungal filaments was 71.4% ± 0% for the experienced observers and 42.9% ± 6.7% for the inexperienced observers. The average specificity was 89.6% ± 3.0% and 87.5% ± 17.7% for these 2 groups of observers, respectively. Although there was a good agreement between the 2 experienced observers (κ = 0.77), the inexperienced observers showed only a moderate interobserver agreement (κ = 0.51). The LS-IVCM sensitivity was higher in patients with fungal infections who had positive culture or longer duration of the disease. Although LS-IVCM has a high specificity for diagnosing filamentous fungal keratitis, its sensitivity is moderate and highly dependent on the level of the observer's experience and training with this imaging modality. Copyright © 2017 Elsevier Inc. All rights reserved.
Nanotechnology: a promising method for oral cancer detection and diagnosis.
Chen, Xiao-Jie; Zhang, Xue-Qiong; Liu, Qi; Zhang, Jing; Zhou, Gang
2018-06-11
Oral cancer is a common and aggressive cancer with high morbidity, mortality, and recurrence rate globally. Early detection is of utmost importance for cancer prevention and disease management. Currently, tissue biopsy remains the gold standard for oral cancer diagnosis, but it is invasive, which may cause patient discomfort. The application of traditional noninvasive methods-such as vital staining, exfoliative cytology, and molecular imaging-is limited by insufficient sensitivity and specificity. Thus, there is an urgent need for exploring noninvasive, highly sensitive, and specific diagnostic techniques. Nano detection systems are known as new emerging noninvasive strategies that bring the detection sensitivity of biomarkers to nano-scale. Moreover, compared to current imaging contrast agents, nanoparticles are more biocompatible, easier to synthesize, and able to target specific surface molecules. Nanoparticles generate localized surface plasmon resonances at near-infrared wavelengths, providing higher image contrast and resolution. Therefore, using nano-based techniques can help clinicians to detect and better monitor diseases during different phases of oral malignancy. Here, we review the progress of nanotechnology-based methods in oral cancer detection and diagnosis.
Tao, Jia; Zhao, Peng; Li, Yinhui; Zhao, Wenjie; Xiao, Yue; Yang, Ronghua
2016-04-28
In the past decades, numerous electrochemical sensors based on exogenous electroactive substance have been reported. Due to non-specific interaction between the redox mediator and the target, the instability caused by false signal may not be avoided. To address this issue, in this paper, a new electrochemical sensor based on spiropyran skeleton, namely SPOSi, was designed for specific electrochemical response to fluoride ions (F(-)). The breakage of Si-O induced by F(-) based on the specific nucleophilic substitution reaction between F(-) and silica would directly produce a hydroquinone structure for electrochemical signal generation. To improve the sensitivity, SPOSi probe was assembled on the single-walled carbon nanotubes (SWCNTs) modified glassy carbon electrode (GCE) through the π-π conjugating interaction. This electrode was successfully applied to monitor F(-) with a detection limit of 8.3 × 10(-8) M. Compared with the conventional F(-) ion selected electrode (ISE) which utilized noncovalent interaction, this method displays higher stability and a comparable sensitivity in the urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Bojunga, Jörg; Kusterer, Klaus; Schumm-Draeger, Petra-Maria; Usadel, Klaus-Henning
2002-12-01
Thyroid cancers are the most common endocrine malignancies and are being diagnosed with increasing frequency. In addition to other measures, diagnosis is based on fine-needle aspiration cytology examination. Recently, new assays using reverse transcription-polymerase chain reaction (PCR) are being tested to improve sensitivity and specificity of primary diagnosis and detection of recurrent thyroid cancer. In the preoperative diagnosis of thyroid cancer, several tissue- and/or tumor-specific mRNA have been described and in several cases, a higher sensitivity and specificity could be achieved using molecular techniques compared to conventional methods. In the postoperative follow-up of patients with thyroid cancer, conflicting data have been published and the use of PCR techniques revealed several problems of the molecular approach, which are based on some technical as well as biologic limitations. Despite these problems, which are discussed in detail in this review, molecular techniques may nevertheless improve the sensitivity and accuracy of fine-needle aspiration of thyroid nodules, fine-needle aspiration of metastases, and detection of recurrent disease in peripheral blood samples.
Nakanishi, Hideo; Akagi, Tadamichi; Hangai, Masanori; Kimura, Yugo; Suda, Kenji; Kumagai, Kyoko Kawashima; Morooka, Satoshi; Ikeda, Hanako Ohashi; Yoshimura, Nagahisa
2015-07-01
We aimed to determine the sensitivity and specificity of the normative database of non-myopic and highly myopic eyes of the macular ganglion cell complex (mGCC) thickness embedded in the NIDEK RS-3000 spectral-domain optical coherence tomography (SD-OCT) for detecting early glaucoma in highly myopic eyes. Forty-seven highly myopic eyes (axial length ≥26.0 mm) of 47 subjects were studied. The SD-OCT images were used to determine the mGCC thickness within a 9-mm diameter circle centered on the fovea. The sensitivity and specificity of the non-myopic database were compared to that of the highly myopic database for distinguishing the early glaucomatous eyes from the non-glaucomatous eyes. The mGCC scans were classified as abnormal if at least one of the eight sectors of the significance map was < 1 % of the normative thickness. Twenty-one eyes were diagnosed to be non-glaucomatous and 26 eyes to have early glaucoma. . The average mGCC thickness was significantly thinner (80.9 ± 8.5 μm) in the early glaucoma group than in the non-glaucomatous group (91.2 ± 7.5 μm; p <1 × 10(-4)). The sensitivity was 96.2 % and specificity was 47.6 % when the non-myopic database was used, and the sensitivity was 92.3 % and the specificity was 90.5 % when the highly myopic database was used. The difference in the specificity was significant (p < 0.01). The significantly higher specificity of the myopic normative database for detecting early glaucoma in highly myopic eyes will lead to fewer false positive diagnoses. The database obtained from highly myopic eyes should be used when evaluating the mGCC thickness of highly myopic eyes.
Noninvasive type 2 diabetes screening: superior sensitivity to fasting plasma glucose and A1C.
Maynard, John D; Rohrscheib, Mark; Way, Jeffrey F; Nguyen, Catriona M; Ediger, Marwood N
2007-05-01
This study compared the performance of a novel noninvasive technology to fasting plasma glucose (FPG) and A1C tests for detecting undiagnosed diabetes and impaired glucose tolerance. The design was a head-to-head evaluation in a naïve population. Consented subjects received FPG and A1C tests and an oral glucose tolerance test (OGTT). Subjects were also measured by a noninvasive device that detects the fluorescence of skin advanced glycation end products. A total of 351 subjects participated. Subjects with 2-h OGTT values > or = 140 mg/dl defined the positive screening class. A total of 84 subjects (23.9% prevalence) screened positive. The performances of the noninvasive device, FPG, and A1C were evaluated for sensitivity and specificity against this classification. At the impaired fasting glucose threshold (FPG = 100 mg/dl), the FPG testing sensitivity was 58% and the specificity was 77.4%. At that same specificity, the sensitivity for A1C testing was 63.8%, while the noninvasive testing sensitivity was 74.7%. The sensitivity advantage of the noninvasive device over both blood tests for detecting diabetes and precursors was statistically significant (P < 0.05). The noninvasive technology showed clinical performance advantages over both FPG and A1C testing. The sensitivity differential indicated that the noninvasive device is capable of identifying 28.8% more individuals in the OGTT-defined positive screening class than FPG testing and 17.1% more than A1C testing. The combination of higher sensitivity and greater convenience--rapid results with no fasting or blood draws--makes the device well suited for opportunistic screening.
Wang, Bi; Yu, Lei; Yang, Guo-Zhen; Luo, Xin; Huang, Lin
2015-01-01
To explore the application of multiplex nested methylated specific polymerase chain reaction (PCR) in the early diagnosis of epithelial ovarian carcinoma (EOC). Serum and fresh tissue samples were collected from 114 EOC patients. RUNX3, TFPI2 and OPCML served as target genes. Methylation levels of tissues were assessed by multiplex nested methylated specific PCR, the results being compared with those for carcinoma antigen 125 (CA125). The serum free deoxyribose nucleic acid (DNA) methylation spectrum of EOC patients was completely contained in the DNA spectrum of cancer tissues, providing an accurate reflection of tumor DNA methylation conditions. Serum levels of CA125 and free DNA methylation in the EOC group were evidently higher than those in benign lesion and control groups (p<0.05). Patients with early EOC had markedly lower serum CA125 than those with advanced EOC (p<0.05), but there was no significant difference in free DNA methylation (p>0.05). The sensitivity, specificity and positive predicative value (PPV) of multiplex nested methylated specific PCR were significantly higher for detection of all patients and those with early EOC than those for CA125 (p<0.05). In the detection of patients with advanced EOC, the PPV of CA125 detection was obviously lower than that of multiplex nested methylated specific PCR (p>0.05), but there was no significant difference in sensitivity (p>0.05). Serum free DNA methylation can be used as a biological marker for EOC and multiplex nested methylated specific PCR should be considered for early diagnosis since it can accurately determine tumor methylation conditions.
Clinical utility of urinary soluble Fas in screening for bladder cancer.
Srivastava, Anupam Kumar; Singh, Pankaj Kumar; Singh, Dhramveer; Dalela, Divakar; Rath, Srikanta Kumar; Bhatt, Madan Lal Brahma
2016-06-01
Early diagnosis of carcinoma of urinary bladder remains a challenge. Urine cytology, as an adjunct to cystoscopy, is less sensitive for low-grade tumors. Soluble Fas (sFas), a cell-surface receptor and member of the tumor necrosis factor superfamily, is frequently expressed in urinary bladder carcinoma. The objective of this study was to investigate the urinary sFas for diagnosis of transitional cell carcinoma (TCC) of urinary bladder. We examined urinary sFas concentration in 74 controls and 117 cases of TCC, both primary and recurrent disease, by using enzyme-linked immunosorbent assay and compared it with urinary cytology. Urinary sFas concentration was found to be significantly higher in the patient as compared to control group (P < 0.05). An optimal cutoff value of 174.0 pg/mL was proposed. The urinary sFas level was found to have an approximate sensitivity and specificity of 88.03% and 89.19% (P < 0.001), whereas urine cytology had sensitivity of 66.67% and specificity of 95.95%. sFas had better sensitivity in higher grade and both primary and recurrent cases of urinary bladder cancer in comparison with cytology. Out of 15 node positive bladder cancer cases, 13 had high urinary sFas levels, whereas 12 were urinary cytology positive for malignancy. Urinary sFas can be used as a non-invasive diagnostic biomarker for TCC of urinary bladder, both for primary and recurrent disease. © 2014 Wiley Publishing Asia Pty Ltd.
PubMed had a higher sensitivity than Ovid-MEDLINE in the search for systematic reviews.
Katchamart, Wanruchada; Faulkner, Amy; Feldman, Brian; Tomlinson, George; Bombardier, Claire
2011-07-01
To compare the performance of Ovid-MEDLINE vs. PubMed for identifying randomized controlled trials of methotrexate (MTX) in patients with rheumatoid arthritis (RA). We created search strategies for Ovid-MEDLINE and PubMed for a systematic review of MTX in RA. Their performance was evaluated using sensitivity, precision, and number needed to read (NNR). Comparing searches in Ovid-MEDLINE vs. PubMed, PubMed retrieved more citations overall than Ovid-MEDLINE; however, of the 20 citations that met eligibility criteria for the review, Ovid-MEDLINE retrieved 17 and PubMed 18. The sensitivity was 85% for Ovid-MEDLINE vs. 90% for PubMed, whereas the precision and NNR were comparable (precision: 0.881% for Ovid-MEDLINE vs. 0.884% for PubMed and NNR: 114 for Ovid-MEDLINE vs. 113 for PubMed). In systematic reviews of RA, PubMed has higher sensitivity than Ovid-MEDLINE with comparable precision and NNR. This study highlights the importance of well-designed database-specific search strategies. Copyright © 2010 Elsevier Inc. All rights reserved.
Délye, C; Laigret, F; Corio-Costet, M F
1997-01-01
We investigated the molecular basis of resistance of the obligate biotrophic grape powdery mildew fungus Uncinula necator to sterol demethylation-inhibiting fungicides (DMIs). The sensitivity of 91 single-spore field isolates of U. necator to triadimenol was assessed by using a leaf disc assay. Resistance factors (RF) ranged from 1.8 to 26.0. The gene encoding the target of DMIs (eburicol 14 alpha-demethylase) from five sensitive and seven resistant isolates was cloned and sequenced. A single mutation, leading to the substitution of a phenylalanine residue for a tyrosine residue at position 136, was found in all isolates exhibiting an RF higher than 5. No mutation was found in sensitive or weakly resistant (RF, < 5) isolates. An allele-specific PCR assay was developed to detect the mutation. Among the 91 isolates tested, only isolates with RF higher than 5 carried the mutation. Three of the 19 resistant isolates and all sensitive and weakly resistant isolates did not possess the mutation. The mutation at codon 136 is thus clearly associated with high levels of resistance to triadimenol. PMID:9251183
Morgado, José Mário T; Sánchez-Muñoz, Laura; Teodósio, Cristina G; Jara-Acevedo, Maria; Alvarez-Twose, Iván; Matito, Almudena; Fernández-Nuñez, Elisa; García-Montero, Andrés; Orfao, Alberto; Escribano, Luís
2012-04-01
Aberrant expression of CD2 and/or CD25 by bone marrow, peripheral blood or other extracutaneous tissue mast cells is currently used as a minor World Health Organization diagnostic criterion for systemic mastocytosis. However, the diagnostic utility of CD2 versus CD25 expression by mast cells has not been prospectively evaluated in a large series of systemic mastocytosis. Here we evaluate the sensitivity and specificity of CD2 versus CD25 expression in the diagnosis of systemic mastocytosis. Mast cells from a total of 886 bone marrow and 153 other non-bone marrow extracutaneous tissue samples were analysed by multiparameter flow cytometry following the guidelines of the Spanish Network on Mastocytosis at two different laboratories. The 'CD25+ and/or CD2+ bone marrow mast cells' World Health Organization criterion showed an overall sensitivity of 100% with 99.0% specificity for the diagnosis of systemic mastocytosis whereas CD25 expression alone presented a similar sensitivity (100%) with a slightly higher specificity (99.2%). Inclusion of CD2 did not improve the sensitivity of the test and it decreased its specificity. In tissues other than bone marrow, the mast cell phenotypic criterion revealed to be less sensitive. In summary, CD2 expression does not contribute to improve the diagnosis of systemic mastocytosis when compared with aberrant CD25 expression alone, which supports the need to update and replace the minor World Health Organization 'CD25+ and/or CD2+' mast cell phenotypic diagnostic criterion by a major criterion based exclusively on CD25 expression.
Validity of self-reported stroke in elderly African Americans, Caribbean Hispanics, and Whites.
Reitz, Christiane; Schupf, Nicole; Luchsinger, José A; Brickman, Adam M; Manly, Jennifer J; Andrews, Howard; Tang, Ming X; DeCarli, Charles; Brown, Truman R; Mayeux, Richard
2009-07-01
The validity of a self-reported stroke remains inconclusive. To validate the diagnosis of self-reported stroke using stroke identified by magnetic resonance imaging (MRI) as the standard. Community-based cohort study of nondemented, ethnically diverse elderly persons in northern Manhattan. High-resolution quantitative MRIs were acquired for 717 participants without dementia. Sensitivity and specificity of stroke by self-report were examined using cross-sectional analyses and the chi(2) test. Putative relationships between factors potentially influencing the reporting of stroke, including memory performance, cognitive function, and vascular risk factors, were assessed using logistic regression models. Subsequently, all analyses were repeated, stratified by age, sex, ethnic group, and level of education. In analyses of the whole sample, sensitivity of stroke self-report for a diagnosis of stroke on MRI was 32.4%, and specificity was 78.9%. In analyses stratified by median age (80.1 years), the validity between reported stroke and detection of stroke on MRI was significantly better in the younger than the older age group (for all vascular territories: sensitivity and specificity, 36.7% and 81.3% vs 27.6% and 26.2%; P = .02). Impaired memory, cognitive skills, or language ability and the presence of hypertension or myocardial infarction were associated with higher rates of false-negative results. Using brain MRI as the standard, specificity and sensitivity of stroke self-report are low. Accuracy of self-report is influenced by age, presence of vascular disease, and cognitive function. In stroke research, sensitive neuroimaging techniques rather than stroke self-report should be used to determine stroke history.
Rumpf, Hans-Jürgen; Hapke, Ulfert; Meyer, Christian; John, Ulrich
2002-01-01
Most screening questionnaires are developed in clinical settings and there are few data on their performance in the general population. This study provides data on the area under the receiver-operating characteristic (ROC) curve, sensitivity, specificity, and internal consistency of the Alcohol Use Disorders Identification Test (AUDIT), the consumption questions of the AUDIT (AUDIT-C) and the Lübeck Alcohol Dependence and Abuse Screening Test (LAST) among current drinkers (n = 3551) of a general population sample in northern Germany. Alcohol dependence and misuse according to DSM-IV and at-risk drinking served as gold standards to assess sensitivity and specificity and were assessed with the Munich-Composite Diagnostic Interview (M-CIDI). AUDIT and LAST showed insufficient sensitivity for at-risk drinking and alcohol misuse using standard cut-off scores, but satisfactory detection rates for alcohol dependence. The AUDIT-C showed low specificity in all criterion groups with standard cut-off. Adjusted cut-points are recommended. Among a subsample of individuals with previous general hospital admission in the last year, all questionnaires showed higher internal consistency suggesting lower reliability in non-clinical samples. In logistic regression analyses, having had a hospital admission increased the sensitivity in detecting any criterion group of the LAST, and the number of recent general practice visits increased the sensitivity of the AUDIT in detecting alcohol misuse. Women showed lower scores and larger areas under the ROC curves. It is concluded that setting specific instruments (e.g. primary care or general population) or adjusted cut-offs should be used.
Meta-analysis of the relative sensitivity of semi-natural vegetation species to ozone.
Hayes, F; Jones, M L M; Mills, G; Ashmore, M
2007-04-01
This study identified 83 species from existing publications suitable for inclusion in a database of sensitivity of species to ozone (OZOVEG database). An index, the relative sensitivity to ozone, was calculated for each species based on changes in biomass in order to test for species traits associated with ozone sensitivity. Meta-analysis of the ozone sensitivity data showed a wide inter-specific range in response to ozone. Some relationships in comparison to plant physiological and ecological characteristics were identified. Plants of the therophyte lifeform were particularly sensitive to ozone. Species with higher mature leaf N concentration were more sensitive to ozone than those with lower leaf N concentration. Some relationships between relative sensitivity to ozone and Ellenberg habitat requirements were also identified. In contrast, no relationships between relative sensitivity to ozone and mature leaf P concentration, Grime's CSR strategy, leaf longevity, flowering season, stomatal density and maximum altitude were found. The relative sensitivity of species and relationships with plant characteristics identified in this study could be used to predict sensitivity to ozone of untested species and communities.
O'Donovan, Aoife; Ahmadian, Ashkan J; Neylan, Thomas C; Pacult, Mark A; Edmondson, Donald; Cohen, Beth E
2017-02-01
Elevated inflammation has been repeatedly observed in posttraumatic stress disorder (PTSD), and it may drive the development of both psychiatric symptoms and physical comorbidities. However, it is not clear if elevated inflammation is a feature of both remitted and current PTSD, and little is known about relationships between specific clusters of PTSD symptoms and inflammation. Exaggerated threat sensitivity, as indexed by threat reactivity and avoidance of perceived threats, may be particularly closely associated with inflammation. We assessed PTSD symptoms and threat sensitivity using the Clinician Administered PTSD Scale in 735 Veterans Affairs patients (35% current PTSD; 16% remitted PTSD) who participated in the Mind Your Heart Study (mean age=59±11; 94% male). High sensitivity C-reactive protein (hsCRP), white blood cell count (WBC), and fibrinogen were used as indices of inflammation. Analysis of covariance models with planned contrasts were used to examine differences in inflammation by PTSD status, adjusting for age, sex, race, kidney function and socioeconomic status. Individuals with current PTSD had significantly higher hsCRP and WBC than patients with no history of PTSD, but there were no significant differences in inflammatory markers between those with remitted versus no history of PTSD. Within patients with current PTSD, higher threat reactivity was independently associated with higher hsCRP (β=0.16, p=0.01) and WBC count (β=0.24, <0.001), and higher effortful avoidance was associated with higher fibrinogen (β=0.13, p=0.04). Our data indicate that elevated inflammation may be a feature of current, but not remitted, PTSD. Within patients with PTSD, higher threat reactivity was also associated with elevated inflammation. A better understanding of the relationship between threat sensitivity and inflammation may inform interventions for patients with PTSD. Copyright © 2016 Elsevier Inc. All rights reserved.
Computed tomography findings of acute gastric volvulus.
Millet, Ingrid; Orliac, Celine; Alili, Chakib; Guillon, Françoise; Taourel, Patrice
2014-12-01
To assess the diagnostic performance of CT signs of gastric volvulus in both confirmed cases and control subjects. We retrospectively reviewed CT findings in 10 patients with surgically confirmed acute gastric volvulus and 20 control subjects with gastric distension. Two radiologists independently evaluated CT images for risk factors of gastric volvulus, direct findings of gastric volvulus by assessing gastric dilatation, the presence of an antropyloric transition point, the respective position of the different stomach segments and of the greater and lesser curvatures, stenosis of the gastric segments through the oesophageal hiatus and for findings of gastric ischemia. The sensitivity and specificity of each finding were calculated. The most sensitive direct signs of gastric volvulus were an antropyloric transition point without any abnormality at the transition zone and the antrum at the same level or higher than the fundus. The presence of both these two findings as diagnostic criteria of gastric volvulus had 100% sensitivity and specificity for the diagnosis of gastric volvulus. There was no association between CT signs of ischemia and final bowel ischemia at pathology. CT is both highly sensitive and specific for diagnosing acute gastric volvulus. CT is highly reliable for diagnosing acute gastric volvulus with two findings. The two signs are gastropyloric transition zone and abnormal location of the antrum. This allows fast surgical management of this emergency.
Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers.
Boelch, Sebastian Philipp; Weissenberger, Manuel; Spohn, Frederik; Rudert, Maximilian; Luedemann, Martin
2018-01-10
Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip.
Emerging Role of Endothelial and Inflammatory Markers in Preeclampsia
Swellam, Menha; Samy, Nervana; Abdl Wahab, Susan; Ibrahim, Mohamed Saeed
2009-01-01
Objectives: Endothelial disturbance and excess inflammatory response are pathogenic mechanisms in pre-eclampsia (PE). Authors determine the clinical diagnostic role for thrombomodulin (TM), plasminogen activator inhibitor-1 (PAI-1) as endothelial markers and C-reactive protein (CRP), and interlukin-6 (IL-6) as inflammatory markers when tested independently or in combinations. Materials and methods: We conducted a retrospective study in a cohort of 185 women grouped as 80 women with PE, 55 normotensive pregnant and 50 healthy non-pregnant. Plasma levels of TM, PAI-1, CRP and IL-6 were examined using enzyme linked immunosorbent assays. Results: Median levels and the positivity rates for the investigated markers were higher in PE as compared to the other groups (P < 0.0001). Using linear regression analysis, the investigated markers were significantly correlated regarding healthy nonpregnant vs PE or normotensive pregnant vs PE. The sensitivity of PAI-1 was the highest (98%) among the tested biomarkers. Combination between the investigated markers revealed absolute sensitivity (100%) and reliable specificity especially when PAI-1 was combined with CRP at 83% specificity. Conclusions: Investigated endothelial and inflammatory markers revealed sensitive diagnostic test for PE. However, coupled combination between PAI-1 with CRP showed superior both sensitivity and specificity which represent a promising new approach for detection of PE. PMID:19597295
Mandal, Goutam; Mandal, Srotoswati; Sharma, Mansi; Charret, Karen Santos; Papadopoulou, Barbara; Bhattacharjee, Hiranmoy; Mukhopadhyay, Rita
2015-01-01
Leishmania is a digenetic protozoan parasite causing leishmaniasis in humans. The different clinical forms of leishmaniasis are caused by more than twenty species of Leishmania that are transmitted by nearly thirty species of phlebotomine sand flies. Pentavalent antimonials (such as Pentostam or Glucantime) are the first line drugs for treating leishmaniasis. Recent studies suggest that pentavalent antimony (Sb(V)) acts as a pro-drug, which is converted to the more active trivalent form (Sb(III)). However, sensitivity to trivalent antimony varies among different Leishmania species. In general, Leishmania species causing cutaneous leishmaniasis (CL) are more sensitive to Sb(III) than the species responsible for visceral leishmaniasis (VL). Leishmania aquaglyceroporin (AQP1) facilitates the adventitious passage of antimonite down a concentration gradient. In this study, we show that Leishmania species causing CL accumulate more antimonite, and therefore exhibit higher sensitivity to antimonials, than the species responsible for VL. This species-specific differential sensitivity to antimonite is directly proportional to the expression levels of AQP1 mRNA. We show that the stability of AQP1 mRNA in different Leishmania species is regulated by their respective 3’-untranslated regions. The differential regulation of AQP1 mRNA explains the distinct antimonial sensitivity of each species. PMID:25714343
Analysis and Implementation of Methodologies for the Monitoring of Changes in Eye Fundus Images
NASA Astrophysics Data System (ADS)
Gelroth, A.; Rodríguez, D.; Salvatelli, A.; Drozdowicz, B.; Bizai, G.
2011-12-01
We present a support system for changes detection in fundus images of the same patient taken at different time intervals. This process is useful for monitoring pathologies lasting for long periods of time, as are usually the ophthalmologic. We propose a flow of preprocessing, processing and postprocessing applied to a set of images selected from a public database, presenting pathological advances. A test interface was developed designed to select the images to be compared in order to apply the different methods developed and to display the results. We measure the system performance in terms of sensitivity, specificity and computation times. We have obtained good results, higher than 84% for the first two parameters and processing times lower than 3 seconds for 512x512 pixel images. For the specific case of detection of changes associated with bleeding, the system responds with sensitivity and specificity over 98%.
In vitro dissolution of pH sensitive microparticles for colon-specific drug delivery.
Barba, Anna Angela; Dalmoro, Annalisa; d'Amore, Matteo; Lamberti, Gaetano
2013-01-01
The objective of this work is to prepare oral dosage systems based on enteric materials in order to verify their possible use as Colon-Specific Drug Delivery Systems (CSDDSs). In particular, three different copolymers of methyl-methacrylate (MMA) - acrylic acid (AA) are synthesized with increasing percentage of MMA (from 70% to 73%) and they are used to produce microparticles by the double-emulsion solvent evaporation method. The microparticles, loaded using theophylline as model drug, are then tested for drug release under varying pH to reproduce what happens in the human GI tract. All the investigated systems have shown an effective pH sensitiveness: they show a good gastro-resistance, releasing the model drug only at higher pH, small intestine or colon, depending on the kind of used copolymer. The results confirm the usefulness of both the materials and the methods proposed in this study for colon-specific delivery applications.
Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony
2015-01-01
This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Morita, Takeshi; Hamada, Shuichi; Masumura, Kenichi; Wakata, Akihiro; Maniwa, Jiro; Takasawa, Hironao; Yasunaga, Katsuaki; Hashizume, Tsuneo; Honma, Masamitsu
2016-05-01
Sensitivity and/or specificity of the in vivo erythrocyte micronucleus (MN) and transgenic rodent mutation (TGR) tests to detect rodent carcinogens and non-carcinogens were investigated. The Carcinogenicity and Genotoxicity eXperience (CGX) dataset created by Kirkland et al. was used for the carcinogenicity and in vitro genotoxicity data, i.e., Ames and chromosome aberration (CA) tests. Broad literature surveys were conducted to gather in vivo MN or TGR test data to add to the CGX dataset. Genotoxicity data in vitro were also updated slightly. Data on 379 chemicals (293 carcinogens and 86 non-carcinogens) were available for the in vivo MN test; sensitivity, specificity or concordances were calculated as 41.0%, 60.5% or 45.4%, respectively. For the TGR test, data on 80 chemicals (76 carcinogens and 4 non-carcinogens) were available; sensitivity was calculated as 72.4%. Based on the recent guidance on genotoxicity testing strategies, performance (sensitivity/specificity) of the following combinations was calculated; Ames+in vivo MN (68.7%/45.3%), Ames+TGR (83.8%/not calculated (nc)), Ames+in vitro CA+in vivo MN (80.8%/21.3%), Ames+in vitro CA+TGR (89.1%/nc), Ames+in vivo MN+TGR (87.5%/nc), Ames+in vitro CA+in vivo MN+TGR (89.3%/nc). Relatively good balance in performance was shown by the Ames+in vivo MN in comparison with Ames+in vitro CA (74.3%/37.5%). Ames+TGR and Ames+in vivo MN+TGR gave even higher sensitivity, but the specificity could not be calculated (too few TGR data on non-carcinogens). This indicates that in vivo MN and TGR tests are both useful as in vivo tests to detect rodent carcinogens. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Song, Lifu; Zeng, An-Ping
2017-11-09
Cells are capable of rapid replication and performing tasks adaptively and ultra-sensitively and can be considered as cheap "biological-robots". Here we propose to engineer cells for screening biomolecules in parallel and with high sensitivity. Specifically, we place the biomolecule variants (library) on the bacterial phage M13. We then design cells to screen the library based on cell-phage interactions mediated by a specific intracellular signal change caused by the biomolecule of interest. For proof of concept, we used intracellular lysine concentration in E. coli as a signal to successfully screen variants of functional aspartate kinase III (AK-III) under in vivo conditions, a key enzyme in L-lysine biosynthesis which is strictly inhibited by L-lysine. Comparative studies with flow cytometry method failed to distinguish the wild-type from lysine resistance variants of AK-III, confirming a higher sensitivity of the method. It opens up a new and effective way of in vivo high-throughput screening for functional molecules and can be easily implemented at low costs.
Olfactory neuroblastoma in dogs and cats--a histological and immunohistochemical analysis.
Brosinski, K; Janik, D; Polkinghorne, A; Von Bomhard, W; Schmahl, W
2012-01-01
Olfactory neuroblastoma (ONB) was identified in 13 dogs and nine cats. The tumours were subjected to microscopical examination and were graded using a human pathological grading system. In the canine and feline tumours there was more necrosis and higher mitotic activity (mitotic index and Ki67 labelling index) than reported in human ONB. Rosettes were a common feature of feline ONBs. A significant correlation was observed between the histological grade and the Ki67 labelling index. The histopathological diagnosis of ONB was confirmed immunohistochemically by demonstration of the neuronal marker neuron-specific enolase (NSE). Two other neuron-specific antibodies specific for microtubule-associated protein-2 (MAP-2) and neuronal nuclei antigen (NeuN) were evaluated. MAP-2 expression proved to have higher specificity than labelling for NSE. NeuN expression was less sensitive and of limited practical value. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kelly, Sharon M; O'Grady, Kevin E; Gryczynski, Jan; Mitchell, Shannon Gwin; Kirk, Arethusa; Schwartz, Robert P
2017-01-01
The Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale has been validated with high school students, adolescents with criminal justice involvement, and adolescent substance use treatment samples using the Diagnostic and Statistical Manual of Mental Disorders (DSM)-III-R and DSM-IV. This study examines the concurrent validity of the POSIT's standard 17-item substance use/abuse subscale and a revised, shorter 11-item version using DSM-5 substance use disorder diagnoses. Adolescents (N = 525; 93% African American, 55% female) 12-17 years of age awaiting primary care appointments at a Federally Qualified Health Center in Baltimore, Maryland completed the 17-item POSIT substance use/abuse subscale and items from a modified World Mental Health Composite International Diagnostic Interview corresponding to DSM-5 alcohol use disorder (AUD) and cannabis use disorder (CUD). Receiver operating characteristic curves, sensitivities, and specificities were examined with DSM-5 AUD, CUD, and a diagnosis of either or both disorders for the standard and revised subscales using risk cutoffs of either 1 or 2 POSIT "yes" responses. For the 17-item subscale, sensitivities were generally high using either cutoff (range: 0.79-1.00), although a cutoff of 1 was superior (sensitivities were 1.00 for AUD, CUD, and for either disorder). Specificities were also high using either cutoff (range: 0.81-0.95) but were higher using a cutoff of 2. For the 11-item subscale, a cutoff of 1 yielded higher sensitivities than a cutoff of 2 (ranges for 1 and 2: 0.96-1.00 and 0.79-0.86, respectively). Specificities for this subscale were higher using a cutoff of 2 (ranges for 1 and 2: 0.82-0.89 and 0.89-0.96, respectively). Findings suggest that the POSIT's substance use/abuse subscale is a potentially useful tool for screening adolescents in primary care for AUD or CUD using a cutoff of 1 or 2. The briefer, revised subscale may be preferable to the standard subscale in busy pediatric practices.
Occupancy Modeling for Improved Accuracy and Understanding of Pathogen Prevalence and Dynamics
Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.
2015-01-01
Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmon Oncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population: Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/ metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%. PMID:25738709
Occupancy modeling for improved accuracy and understanding of pathogen prevalence and dynamics
Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.
2015-01-01
Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmonOncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population:Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%.
Li, Tiantian; Ban, Jie; Horton, Radley M; Bader, Daniel A; Huang, Ganlin; Sun, Qinghua; Kinney, Patrick L
2015-08-06
Because heat-related health effects tend to become more serious at higher temperatures, there is an urgent need to determine the mortality projection of specific heat-sensitive diseases to provide more detailed information regarding the variation of the sensitivity of such diseases. In this study, the specific mortality of cardiovascular and respiratory disease in Beijing was initially projected under five different global-scale General Circulation Models (GCMs) and two Representative Concentration Pathways scenarios (RCPs) in the 2020s, 2050s, and 2080s compared to the 1980s. Multi-model ensembles indicated cardiovascular mortality could increase by an average percentage of 18.4%, 47.8%, and 69.0% in the 2020s, 2050s, and 2080s under RCP 4.5, respectively, and by 16.6%,73.8% and 134% in different decades respectively, under RCP 8.5 compared to the baseline range. The same increasing pattern was also observed in respiratory mortality. The heat-related deaths under the RCP8.5 scenario were found to reach a higher number and to increase more rapidly during the 21(st) century compared to the RCP4.5 scenario, especially in the 2050s and the 2080s. The projection results show potential trends in cause-specific mortality in the context of climate change, and provide support for public health interventions tailored to specific climate-related future health risks.
NASA Astrophysics Data System (ADS)
Li, Tiantian; Ban, Jie; Horton, Radley M.; Bader, Daniel A.; Huang, Ganlin; Sun, Qinghua; Kinney, Patrick L.
2015-08-01
Because heat-related health effects tend to become more serious at higher temperatures, there is an urgent need to determine the mortality projection of specific heat-sensitive diseases to provide more detailed information regarding the variation of the sensitivity of such diseases. In this study, the specific mortality of cardiovascular and respiratory disease in Beijing was initially projected under five different global-scale General Circulation Models (GCMs) and two Representative Concentration Pathways scenarios (RCPs) in the 2020s, 2050s, and 2080s compared to the 1980s. Multi-model ensembles indicated cardiovascular mortality could increase by an average percentage of 18.4%, 47.8%, and 69.0% in the 2020s, 2050s, and 2080s under RCP 4.5, respectively, and by 16.6%,73.8% and 134% in different decades respectively, under RCP 8.5 compared to the baseline range. The same increasing pattern was also observed in respiratory mortality. The heat-related deaths under the RCP8.5 scenario were found to reach a higher number and to increase more rapidly during the 21st century compared to the RCP4.5 scenario, especially in the 2050s and the 2080s. The projection results show potential trends in cause-specific mortality in the context of climate change, and provide support for public health interventions tailored to specific climate-related future health risks.
Li, Tiantian; Ban, Jie; Horton, Radley M.; Bader, Daniel A.; Huang, Ganlin; Sun, Qinghua; Kinney, Patrick L.
2015-01-01
Because heat-related health effects tend to become more serious at higher temperatures, there is an urgent need to determine the mortality projection of specific heat-sensitive diseases to provide more detailed information regarding the variation of the sensitivity of such diseases. In this study, the specific mortality of cardiovascular and respiratory disease in Beijing was initially projected under five different global-scale General Circulation Models (GCMs) and two Representative Concentration Pathways scenarios (RCPs) in the 2020s, 2050s, and 2080s compared to the 1980s. Multi-model ensembles indicated cardiovascular mortality could increase by an average percentage of 18.4%, 47.8%, and 69.0% in the 2020s, 2050s, and 2080s under RCP 4.5, respectively, and by 16.6%,73.8% and 134% in different decades respectively, under RCP 8.5 compared to the baseline range. The same increasing pattern was also observed in respiratory mortality. The heat-related deaths under the RCP8.5 scenario were found to reach a higher number and to increase more rapidly during the 21st century compared to the RCP4.5 scenario, especially in the 2050s and the 2080s. The projection results show potential trends in cause-specific mortality in the context of climate change, and provide support for public health interventions tailored to specific climate-related future health risks. PMID:26247438
Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay
NASA Astrophysics Data System (ADS)
Serebrennikova, Kseniya; Samsonova, Jeanne; Osipov, Alexander
2018-06-01
Lateral flow immunoassay (LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation. However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications. In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis. LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5-10 ng mL-1 with the limit of detection of 0.1 ng mL-1, which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method, which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents (antibodies).
He, Xiwei; Liu, Peng; Zheng, Guolu; Chen, Huimei; Shi, Wei; Cui, Yibin; Ren, Hongqiang; Zhang, Xu-Xiang
2016-01-01
This study systematically evaluated five microbial and four mitochondrial DNA (mtDNA) markers, including sensitivities and specificities under PCR method, and fecal concentrations and decay rates in water under qPCR method. The microbial DNA markers were the three human-associated (BacH, HF183 and B.adolescentis) and two pig-associated (Pig-2-Bac and L.amylovorus), while the mtDNA ones were two human- (H-ND6 and H-ND5) and two pig-associated (P-CytB and P-ND5). All the mtDNA markers showed higher sensitivity (100%) than the microbial ones (84.0–88.8%) except Pig-2-Bac (100%). Specificities of the human mtDNA markers (99.1 and 98.1%) were higher than those of the human-associated microbial ones (57.0–88.8%). But this pattern was not observed in the pig-associated markers where Pig-2-Bac had 100% specificity. The reliability of H-ND6 and H-ND5 was further evidenced to identify locations of the most polluted within the Taihu Lake watershed of China. In general, the microbial DNA markers demonstrated a higher fecal concentration than the mtDNA ones; increasing temperature and sunlight exposure accelerated significantly the decay of all the DNA markers. Results of this study suggest that DNA markers H-ND6, H-ND5, and Pig-2-Bac may be among the best for fecal source tracking in water. PMID:27734941
Vigliecca, Nora Silvana
2017-11-09
To study the relationship between the caregiver's perception about the patient's impairment in spontaneous speech, according to an item of four questions administered by semi-structured interview, and the patient's performance in the Brief Aphasia Evaluation (BAE). 102 right-handed patients with focal brain lesions of different types and location were examined. BAE is a valid and reliable instrument to assess aphasia. The caregiver's perception was correlated with the item of spontaneous speech, the total score and the three main factors of the BAE: Expression, Comprehension and Complementary factors. The precision (sensitivity/ specificity) about the caregiver's perception of the patient's spontaneous speech was analyzed with reference to the presence or absence of disorder, according to the professional, on the BAE item of spontaneous speech. The studied correlation was satisfactory, being greater (higher than 80%) for the following indicators: the item of spontaneous speech, the Expression factor and the total score of the scale; the correlation was a little smaller (higher than 70%) for the Comprehension and Complementary factors. Comparing two cut-off points that evaluated the precision of the caregiver's perception, satisfactory results were observed in terms of sensitivity and specificity (>70%) with likelihood ratios higher than three. By using the median as the cut-off point, more satisfactory diagnostic discriminations were obtained. Interviewing the caregiver specifically on the patient's spontaneous speech, in an abbreviated form, provides relevant information for the aphasia diagnosis.
NASA Astrophysics Data System (ADS)
He, Xiwei; Liu, Peng; Zheng, Guolu; Chen, Huimei; Shi, Wei; Cui, Yibin; Ren, Hongqiang; Zhang, Xu-Xiang
2016-10-01
This study systematically evaluated five microbial and four mitochondrial DNA (mtDNA) markers, including sensitivities and specificities under PCR method, and fecal concentrations and decay rates in water under qPCR method. The microbial DNA markers were the three human-associated (BacH, HF183 and B.adolescentis) and two pig-associated (Pig-2-Bac and L.amylovorus), while the mtDNA ones were two human- (H-ND6 and H-ND5) and two pig-associated (P-CytB and P-ND5). All the mtDNA markers showed higher sensitivity (100%) than the microbial ones (84.0-88.8%) except Pig-2-Bac (100%). Specificities of the human mtDNA markers (99.1 and 98.1%) were higher than those of the human-associated microbial ones (57.0-88.8%). But this pattern was not observed in the pig-associated markers where Pig-2-Bac had 100% specificity. The reliability of H-ND6 and H-ND5 was further evidenced to identify locations of the most polluted within the Taihu Lake watershed of China. In general, the microbial DNA markers demonstrated a higher fecal concentration than the mtDNA ones; increasing temperature and sunlight exposure accelerated significantly the decay of all the DNA markers. Results of this study suggest that DNA markers H-ND6, H-ND5, and Pig-2-Bac may be among the best for fecal source tracking in water.
Lee, Jung Hwan; Lee, Sang-Ho
2012-10-01
To compare the clinical implications of electro-diagnostic study with those of magnetic resonance imaging in patients with lumbosacral intervertebral herniated disc or spinal stenosis. Retrospective study of clinical data. Patients with lumbosacral intervertebral herniated disc or spinal stenosis, diagnosed by clinical assessment and magnetic resonance imaging (MRI), were selected. A total of 753 patients (437 with lumbosacral intervertebral herniated disc and 316 with spinal stenosis) were included in the study. Clinical data for electrodiagnostic study (EDX)and MRI were compared and the sensitivity and specificity of these studies were evaluated. Among all subjects, 267 had radiculopathy on EDX (EDX (+)) and 486 no radiculopathy (EDX(-)). Furthermore, 391 had root compression on MRI (MRI (+)) and 362 no root compression on MRI (MRI (-)). Patients with radioculopathy on EDX (+) showed a significantly higher visual analogue scale score for radiating pain and a higher Oswestry Disability Index than those with negative findings by EDX (-) in the total subjects group and the lumbosacral intervertebral herniated disc subgroup, and there was a trend toward higher Oswestry Disability Index in the spinal stenosis subgroup. Although patients with radioculopathy on root compression on MRI (+) also had a higher visual analogue scale for radiating pain than patients with negative findings by MRI (-) in the total subjects group and the lumbosacral intervertebral herniated disc subgroup, no significant difference was seen in the Oswestry Disability Index. EDX revealed a significant correlation with muscle weakness in the total subjects group and the lumbosacral intervertebral herniated disc subgroup, and trends toward muscle weakness in the spinal stenosis subgroup, whereas there was no such significant correlation for MRI findings in any group. Electrodiagnostic study had a higher specificity in terms of physical examination data than MRI, in spite of its lower sensitivity. Electrodiagnostic study was significantly more correlated with clinical data, especially leg muscle weakness and functional status, and showed a higher specificity than MRI in patients with lumbosacral intervertebral herniated disc or spinal stenosis.
Panneum, S; Rukkwamsuk, T
2017-03-01
For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.
Kumbak, Banu; Oral, Engin; Karlikaya, Guvenc; Lacin, Selman; Kahraman, Semra
2006-10-01
The aim of this study was to assess the clinical value of serum oestradiol concentration 8 days after embryo transfer (D8E2) and beta-human chorionic gonadotrophin (HCG-beta) concentration 12 days after embryo transfer (D12HCG-beta) in the prediction of pregnancy and the outcome of pregnancy following assisted reproduction, taking into account the day of transfer, which was either day 3 (D3) or day 5 (D5). The objective was to improve patient counselling by giving quantitative and reliable predictive information instead of non-specific uncertainties. A total of 2035 embryo transfer cycles performed between January 2003 and June 2005 were analysed retrospectively. Biochemical pregnancy, ectopic pregnancy and first-trimester abortions were classified as non-viable pregnancies; pregnancies beyond 12 weeks gestation were classified as ongoing pregnancies (OP). Significantly higher D8E2 and D12HCG-beta were obtained in D5 transfers compared with D3 transfers with regard to pregnancy and OP (P
Hontoir, Fanny; Nisolle, Jean-François; Meurisse, Hubert; Simon, Vincent; Tallier, Max; Vanderstricht, Renaud; Antoine, Nadine; Piret, Joëlle; Clegg, Peter; Vandeweerd, Jean-Michel
2014-01-01
Articular cartilage defects are prevalent in metacarpo/metatarsophalangeal (MCP/MTP) joints of horses. The aim of this study was to determine and compare the sensitivity and specificity of 3-Tesla magnetic resonance imaging (3-T MRI) and computed tomography arthrography (CTA) to identify structural cartilage defects in the equine MCP/MTP joint. Forty distal cadaver limbs were imaged by CTA (after injection of contrast medium) and by 3-T MRI using specific sequences, namely, dual-echo in the steady-state (DESS), and sampling perfection with application-optimised contrast using different flip-angle evolutions (SPACE). Gross anatomy was used as the gold standard to evaluate sensitivity and specificity of both imaging techniques. CTA sensitivity and specificity were 0.82 and 0.96, respectively, and were significantly higher than those of MRI (0.41 and 0.93, respectively) in detecting overall cartilage defects (no defect vs. defect). The intra and inter-rater agreements were 0.96 and 0.92, respectively, and 0.82 and 0.88, respectively, for CT and MRI. The positive predictive value for MRI was low (0.57). CTA was considered a valuable tool for assessing cartilage defects in the MCP/MTP joint due to its short acquisition time, its specificity and sensitivity, and it was also more accurate than MRI. However, MRI permits assessment of soft tissues and subchondral bone and is a useful technique for joint evaluation, although clinicians should be aware of the limitations of this diagnostic technique, including reduced accuracy. Copyright © 2013 Elsevier Ltd. All rights reserved.
CSF soluble amyloid precursor proteins in the diagnosis of incipient Alzheimer disease.
Perneczky, R; Tsolakidou, A; Arnold, A; Diehl-Schmid, J; Grimmer, T; Förstl, H; Kurz, A; Alexopoulos, P
2011-07-05
To explore if soluble amyloid precursor proteins (sAPP) in CSF improve the identification of patients with incipient Alzheimer disease (AD) in a group of patients with mild cognitive impairment (MCI). A cohort study with follow-up assessments of 58 patients with MCI with baseline CSF sampling was conducted: 21 patients had progressed to probable AD (MCI-AD), 27 still had MCI, 8 had reverted to normal (MCI-NAD), and 2 patients with frontotemporal dementia (FTD) were excluded. Sixteen additional patients with FTD were included to explore the specificity of the CSF markers. CSF concentrations of sAPPα, sAPPβ, tau, and Aβ(1-42) were measured with sensitive and specific ELISAs. Associations between diagnostic status, CSF protein concentrations, and other patient characteristics were explored using multiple logistic regression analyses with stepwise variable selection. The optimal sensitivity and specificity of the best models were derived from receiver operating characteristic curves. The MCI-AD group had significantly higher sAPPβ concentrations than the MCI-NAD and the FTD groups. A combination of sAPPβ, tau, and age differentiated the MCI-AD and the MCI-NAD groups with a sensitivity of 80.00% and a specificity of 81.00%. The best model for the differentiation of the MCI-AD and the FTD groups included sAPPβ and tau, and showed a sensitivity of 95.20% and a specificity of 81.20%. Aβ(1-42) and sAPPα did not significantly contribute to the models. These findings suggest that sAPPβ may be clinically useful, and superior to Aβ(1-42), in the early and differential diagnosis of incipient AD.
Uhlig, Johannes; Uhlig, Annemarie; Kunze, Meike; Beissbarth, Tim; Fischer, Uwe; Lotz, Joachim; Wienbeck, Susanne
2018-05-24
The purpose of this study is to evaluate the diagnostic performance of machine learning techniques for malignancy prediction at breast cone-beam CT (CBCT) and to compare them to human readers. Five machine learning techniques, including random forests, back propagation neural networks (BPN), extreme learning machines, support vector machines, and K-nearest neighbors, were used to train diagnostic models on a clinical breast CBCT dataset with internal validation by repeated 10-fold cross-validation. Two independent blinded human readers with profound experience in breast imaging and breast CBCT analyzed the same CBCT dataset. Diagnostic performance was compared using AUC, sensitivity, and specificity. The clinical dataset comprised 35 patients (American College of Radiology density type C and D breasts) with 81 suspicious breast lesions examined with contrast-enhanced breast CBCT. Forty-five lesions were histopathologically proven to be malignant. Among the machine learning techniques, BPNs provided the best diagnostic performance, with AUC of 0.91, sensitivity of 0.85, and specificity of 0.82. The diagnostic performance of the human readers was AUC of 0.84, sensitivity of 0.89, and specificity of 0.72 for reader 1 and AUC of 0.72, sensitivity of 0.71, and specificity of 0.67 for reader 2. AUC was significantly higher for BPN when compared with both reader 1 (p = 0.01) and reader 2 (p < 0.001). Machine learning techniques provide a high and robust diagnostic performance in the prediction of malignancy in breast lesions identified at CBCT. BPNs showed the best diagnostic performance, surpassing human readers in terms of AUC and specificity.
[Sublingual immunotherapy with cat epithelial extract. Personal experience].
Sánchez Palacios, A; Schamann, F; García, J A
2001-01-01
Because cats are a common pet in many houses and tourist complexes in the Canary Islands, sensitization to cat epithelium is a frequent problem. A total of 19.2% of patients with intrinsic asthma are sensitized to cat epithelium. In the Canary Islands, the percentage of sensitization among patients with a household cat is 18.1%, which higher is higher than in the rest of Spain (11.9). Many patients with extrinsic asthma sensitized to house dust mites undergo conventional subcutaneous immunotherapy but evolution is unsatisfactory due to sensitization to cat epithelium (whether a cat is present or not). The aim of this study was to evaluate the clinical effectiveness of sublingual immunotherapy with extract of cat epithelium in monosensitized patients with perennial allergic rhinitis and/or bronchial asthma. Forty patients monosensitized to cat epithelium were selected. Of these, 20 were administered sublingual immunotherapy and another 20 received placebo. The following evaluation was carried out in both groups: in vivo and in vitro: symptom score, skin tests, nasal challenge with cat epithelium, specific IgE determination, specific IgG4 and eosinophilic cationic protein. After 1 year of treatment the cumulative dose was 3.6 micrograms of Fe ld I, equivalent to 10 ng/drop. Duration of treatment was 365 days. Our conclusions, based on our patients in the Canary Islands, were the following: 1. Sublingual Fel d I therapy is effective after 1 year of treatment. 2. There were no modifications in IgE, eosinophilic cationic protein or skin tests. 3. An increase in IgG4 occurred which was related to clinical improvement. 4. In general, tolerance was good, except in one patient who presented urticaria and sublingual pruritus. 5. In polysensitized patients, sublingual immunotherapy to cat epithelium is complementary to immunotherapy to dermatophagoides.
Duncan, Stephen T; Khazzam, Michael S; Burnham, Jeremy M; Spindler, Kurt P; Dunn, Warren R; Wright, Rick W
2015-02-01
The purpose of this study was to perform a systematic review of the available literature to define the level of quality evidence for determining the sensitivity and specificity of different radiographic views in detecting knee osteoarthritis and to determine the impact of different grading systems on the ability to detect knee osteoarthritis. A systematic review of the literature was conducted to identify studies that evaluated the standing anteroposterior (AP) and 45° posteroanterior (PA) views for tibiofemoral and patellofemoral arthritis and those comparing the use of the Kellgren-Lawrence versus the joint space narrowing (JSN) radiographic grading systems using arthroscopy as the gold standard. A comprehensive search of PubMed, Scopus, CINAHL, the Cochrane Database, Clinicaltrial.gov, and EMBASE was performed using the keywords "osteoarthritis," "knee," "x-ray," "sensitivity," and "arthroscopy." Six studies were included in the evaluation. The 45° flexion PA view showed a higher sensitivity than the standing AP view for detecting severe arthritis involving either the medial or lateral tibiofemoral compartment. There was no difference in the specificities for the 2 views. The direct comparison of the Kellgren-Lawrence and the JSN radiographic grading systems found no clinical difference between the 2 systems regarding the sensitivities, although the specificity was greater for the JSN system. The ability to detect knee osteoarthritis continues to be difficult without using advanced imaging. However, as an inexpensive screening tool, the 45° flexion PA view is more sensitive than the standing AP view to detect severe tibiofemoral osteoarthritis. When evaluating the radiograph for severe osteoarthritis using either the Kellgren-Lawrence or JSN grading system, there is no clinical difference in the sensitivity between the 2 methods; however, the JSN may be more specific for ruling in severe osteoarthritis in the medial compartment. Level I, systematic review of Level I studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Perfluoroalkyl substances and food allergies in adolescents.
Buser, Melanie C; Scinicariello, Franco
2016-03-01
Perfluoroalkyl and polyfluoroalkyl substances (PFASs) are a class of organic compounds that are persistent in the environment due to their stable carbon-fluorine backbone, which is not susceptible to degradation. Research suggests these chemicals may exert an immunotoxic effect. The aim of this study is to investigate the associations between four PFASs - perfluorooctane sulfonic acid (PFOS), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorohexane sulfonic acid (PFHxS) - with food sensitization and food allergies in adolescent participants (ages 12-19years) in the National Health and Nutrition Examination Survey (NHANES) 2005-2006 and 2007-2010, respectively. We performed multivariate logistic regression to analyze the association between individual PFASs with food sensitization (defined as having at least 1 food-specific IgE level≥0.35kU/L) in NHANES 2005-2006 and food allergies (self-reported) in NHANES 2007-2010. Serum PFOA, PFOS, and PFHxS were statistically significantly associated with higher odds to have self-reported food allergies in NHANES 2007-2010. When using IgE levels as a marker of food sensitization, we found that serum PFNA was inversely associated with food sensitization (NHANES 2005-2006). In conclusion, we found that serum levels of PFASs were associated with higher odds to have self-reported food allergies. Conversely, adolescents with higher serum PFNA were less likely to be sensitized to food allergens. These results, along with previous studies, warrant further investigation, such as well-designed longitudinal studies. Published by Elsevier Ltd.
Kawakami, Ryoko; Miyachi, Motohiko
2010-10-01
This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.
Bee sting allergy in beekeepers.
Eich-Wanger, C; Müller, U R
1998-10-01
Beekeepers are strongly exposed to honey bee stings and therefore at an increased risk to develop IgE-mediated allergy to bee venom. We wondered whether bee venom-allergic beekeepers were different from normally exposed bee venom-allergic patients with regard to clinical and immunological parameters as well as their response to venom immunotherapy. Among the 459 bee venom-allergic patients seen over the 5 year period 1987-91, 62 (14%) were beekeepers and 44 (10%) family members of beekeepers. These two groups were compared with 101 normally exposed bee venom-allergic patients matched with the allergic beekeepers for age and sex, regarding clinical parameters, skin sensitivity, specific IgE and IgG antibodies to bee venom as well as safety and efficacy of venom immunotherapy. As expected, allergic beekeepers had been stung most frequently before the first allergic reaction. The three groups showed a similar severity of allergic symptoms following bee stings and had an equal incidence of atopic diseases. Allergic beekeepers showed higher levels of bee venom-specific serum IgG, lower skin sensitivity and lower levels of bee venom specific serum IgE than bee venom-allergic control patients. A negative correlation between number of stings and skin sensitivity as well as specific IgE was found in allergic beekeepers and their family members, while the number of stings was positively correlated with specific IgG in these two groups. Venom immunotherapy was equally effective in the three groups, but better tolerated by allergic beekeepers than the two other groups. The majority of allergic beekeepers continued bee-keeping successfully under the protection of venom immunotherapy. The lower level of sensitivity in diagnostic tests and the better tolerance of immunotherapy in allergic beekeepers is most likely related to the high level of specific IgG in this group.
Measuring the Degree of Sensitization (DOS) Using an Electrochemical Technique
NASA Astrophysics Data System (ADS)
Abuzriba, Mokhtar B.; Musa, Salem M.
Sensitization can be simply defined as the susceptibility of an alloy, specifically austenitic stainless steel, to
Cross allergic reactions in infants and toddlers with atopic dermatitis.
Cudowska, B; Kaczmarski, M; Wasilewska, J
2013-01-01
Prevalence and clinical significance of cross sensitization in children up to 3 years old, diagnosed with atopic dermatitis. The retrospective study included 69 children up to 3 years old with atopic dermatitis. Allergological diagnostics was performed based on skin tests, determination of total IgE concentration and allergen-specific IgE. Cross sensitization was found in 26% of children. Other patients were qualified to the control group. The sensitization to trees pollen and fruits as well as grass pollen and vegetables were the most frequent types of cross allergy. The patient's family history was positive with regard to atopy in 72% of children from the study group vs. 31% of children from the control group. The statistically higher prevalence of allergic rhinitis and bronchial asthma as well as co-existence of sensitization to house dust mite and animal dander were revealed in the study group. The total concentration of IgE, eosinophilia and SCORAD values were statistically higher in the study group. Children with cross sensitization required systemic steroid therapy more frequently. In children up to 3 years with atopic dermatitis and sensitization to plant pollen, the role of a pollen-food allergy syndrome must be taken into account in the pathogenesis of the disease. In children with cross sensitization, the course of atopic dermatitis is more severe; the symptoms from the respiratory and digestive system co-exist. The positive family history is a factor, predisposing to the development of cross sensitization in infants and toddlers.
Cáceres, Diego H; Zuluaga, Alejandra; Tabares, Ángela M; Chiller, Tom; González, Ángel; Gómez, Beatriz L
2017-12-21
A Lateral Flow Assay to detect cryptococcal antigen (CrAg® LFA) in serum and cerebrospinal fluid for the rapid diagnosis of cryptococcosis was evaluated. A retrospective validation was performed. Sensitivity and specificity of the CrAg® LFA was 100%. High concordance (kappa index=1.0) between Cryptococcal Antigen Latex Agglutination System (CALAS®) and CrAg® LFA was observed. CrAg® LFA showed higher analytical sensitivity for detecting low concentrations of cryptococcal antigen.
Cáceres, Diego H.; Zuluaga, Alejandra; Tabares, Ángela M.; Chiller, Tom; González, Ángel; Gómez, Beatriz L.
2017-01-01
ABSTRACT A Lateral Flow Assay to detect cryptococcal antigen (CrAg® LFA) in serum and cerebrospinal fluid for the rapid diagnosis of cryptococcosis was evaluated. A retrospective validation was performed. Sensitivity and specificity of the CrAg® LFA was 100%. High concordance (kappa index=1.0) between Cryptococcal Antigen Latex Agglutination System (CALAS®) and CrAg® LFA was observed. CrAg® LFA showed higher analytical sensitivity for detecting low concentrations of cryptococcal antigen. PMID:29267584
Sordillo, Joanne E; Webb, Tara; Kwan, Doris; Kamel, Jimmy; Hoffman, Elaine; Milton, Donald K; Gold, Diane R
2011-01-01
Background Studies on airway inflammation, measured as fraction exhaled nitric oxide (FENO), have focused on its relation to control of asthma, but the contribution of allergen exposure to elevation of FENO is unknown. Objective We evaluated (1) whether FENO was elevated in children with allergic sensitization or asthma; (2) whether specific allergen exposure increased FENO levels in sensitized, but not in unsensitized children; and (3) whether sedentary behavior increased FENO, independent of allergen exposures. Methods At age 12, in a birth cohort of children with parental history of allergy or asthma, we measured bed dust allergen (dust mite, cat, cockroach) by ELISA; specific allergic sensitization primarily by specific IgE ; and respiratory disease (current asthma, rhinitis, and wheeze) and hours of TV viewing/video game playing by questionnaire. Children performed spirometry maneuvers before and after bronchodilator responses, and had FENO measured using electrochemical detection methods (NIOX MINO). Results FENO was elevated in children with current asthma (32.2 ppb), wheeze (27.0 ppb), or rhinitis (23.2ppb) as compared to individuals without these respective symptoms/diagnoses (16.4 ppb to 16.6 ppb, p< 0.005 for all comparisons). Allergic sensitization to indoor allergens (cat, dog, dust mite) predicted higher levels of FENO, and explained one third of the variability of FENO. FENO levels were highest in children both sensitized and exposed to dust mite. Greater than 10 hours of weekday TV viewing was associated with a 0.64 log increase in FENO, after controlling indoor allergen exposure, BMI and allergic sensitization. Conclusion Allergen exposures and sedentary behavior (TV viewing/ video game playing), may increase airway inflammation, measured as FENO. PMID:21463890
Serra, Montserrat; Brazís, Pilar; Fondati, Alessandra; Puigdemont, Anna
2006-11-01
To assess binding of IgE to native, whole hydrolyzed, and separated hydrolyzed fractions of soy protein in serum obtained from dogs with experimentally induced soy protein hypersensitivity. 8 naïve Beagles (6 experimentally sensitized to native soy protein and 2 control dogs). 6 dogs were sensitized against soy protein by administration of allergens during a 90-day period. After the sensitization protocol was completed, serum concentrations of soy-specific IgE were measured and intradermal skin tests were performed in all 6 dogs to confirm that the dogs were sensitized against soy protein. Serum samples from each sensitized and control dog underwent western blot analysis to assess the molecular mass band pattern of the different allergenic soy fractions and evaluate reactivities to native and hydrolyzed soy protein. In sera from sensitized dogs, a characteristic band pattern with 2 major bands (approx 75 and 50 kd) and 2 minor bands (approx 31 and 20 kd) was detected, whereas only a diffuse band pattern associated with whole hydrolyzed soy protein was detected in the most reactive dog. Reactivity was evident only for the higher molecular mass peptide fraction. In control dogs, no IgE reaction to native or hydrolyzed soy protein was detected. Data suggest that the binding of soy-specific IgE to the hydrolyzed soy protein used in the study was significantly reduced, compared with binding of soy-specific IgE to the native soy protein, in dogs with experimentally induced soy hypersensitivity.
Attallah, Abdelfattah M; El-Far, Mohamed; Abdallah, Sanaa O; El-Waseef, Ahmed M; Omran, Mohamed M; Abdelrazek, Mohamed A; Attallah, Ahmed A; Saadh, Mohamed J; Radwan, Mohamed; El-waffaey, Kholoud A; Abol-Enei, Hassan
2015-11-11
The advent of noninvasive urine-based markers as well as other novel modalities has yielded improved diagnostic accuracy. However, the new markers failed to reach higher sensitivity and specificity. We therefore evaluated the potential role of epithelial membrane antigen (EMA) and nuclear matrix protein 52 (NMP-52) singly and combined as noninvasive biomarkers for the detection of bladder cancer (BC). A total of 160 individuals including 66 patients with BC, 54 patients with benign urologic disorders and 40 healthy volunteers were investigated. Urinary EMA at 130 kDa and NMP at 52 kDa were identified, purified and quantified by Western blot, electroelution and enzyme-linked immunosorbent assay (ELISA). The diagnostic performance of each biomarker and their combination were compared using area under receiver operating characteristic curves (AUC). Mean urinary EMA, 2.42 µg/mL, and NMP-52, 17.85 µg/mL, were significantly elevated in patients with BC compared to controls, 1.18 and 3.44 µg/mL, respectively (p<0.0001). The combined use of these markers yielded values which were increased 4.4- and 13.7-fold in the benign and malignant disease groups, respectively, with respect to the normal group. The values of EMA and NMP-52 were significantly higher in patients with higher-grade tumors than those with lower-grade tumors (p<0.0001). Moreover, this combination could predict all BC stages and grades with 0.91 AUC, 94% sensitivity and 80% specificity. EMA and NMP-52 in combination could be promising noninvasive biomarkers for BC detection.
Wang, Qiao
2018-05-25
To prospectively evaluate the diagnostic performance of three-dimensional (3D) shear wave elastography (SWE) for breast lesions with quantitative stiffness information from transverse, sagittal and coronal planes. Conventional ultrasound (US), two-dimensional (2D)-SWE and 3D-SWE were performed for 122 consecutive patients with 122 breast lesions before biopsy or surgical excision. Maximum elasticity values of Young's modulus (Emax) were recorded on 2D-SWE and three planes of 3D-SWE. Area under the receiver operating characteristic curve (AUC), sensitivity and specificity of US, 2D-SWE and 3D-SWE were evaluated. Two combined sets (i.e., BI-RADS and 2D-SWE; BI-RADS and 3D-SWE) were compared in AUC. Observer consistency was also evaluated. On 3D-SWE, the AUC and sensitivity of sagittal plane were significantly higher than those of transverse and coronal planes (both P < 0.05). Compared with BI-RADS alone, both combined sets had significantly (P < 0.05) higher AUCs and specificities, whereas, the two combined sets showed no significant difference in AUC (P > 0.05). However, the combined set of BI-RADS and sagittal plane of 3D-SWE had significantly higher sensitivity than the combined set of BI-RADS and 2D-SWE. The sagittal plane shows the best diagnostic performance among 3D-SWE. The combination of BI-RADS and 3D-SWE is a useful tool for predicting breast malignant lesions in comparison with BI-RADS alone.
Two methods for increased specificity and sensitivity in loop-mediated isothermal amplification
USDA-ARS?s Scientific Manuscript database
The technique of loop-mediated isothermal amplification (LAMP) utilizes 4 (or 6) primers targeting 6 (or 8) regions within a fairly small segment of a genome for amplification, with concentration higher than that used in traditional PCR methods. The high concentrations of primers used leads to an in...
ERIC Educational Resources Information Center
Hulme, Julie A.; Kitching, Helen J.
2017-01-01
This paper describes one aspect of a larger scale qualitative study conducted to investigate psychology-specific issues in learning and teaching in higher education. Participants included academic psychologists from across the career spectrum and from diverse UK universities. A semi-structured focus group methodology was employed, and results were…
Diagnosis of mold allergy by RAST and skin prick testing.
Nordvall, S L; Agrell, B; Malling, H J; Dreborg, S
1990-11-01
Sera from 33 patients with mold allergy proven by bronchial provocation were analyzed for specific IgE against six mold species comparing an improved Phadebas RAST with four other techniques. The new method was more sensitive and gave significantly higher IgE antibody concentrations for all tested molds except Cladosporium herbarum.
Gruver, Aaron M; Liu, Ling; Vaillancourt, Peter; Yan, Sau-Chi B; Cook, Joel D; Roseberry Baker, Jessica A; Felke, Erin M; Lacy, Megan E; Marchal, Christophe C; Szpurka, Hadrian; Holzer, Timothy R; Rhoads, Emily K; Zeng, Wei; Wortinger, Mark A; Lu, Jirong; Chow, Chi-kin; Denning, Irene J; Beuerlein, Gregory; Davies, Julian; Hanson, Jeff C; Credille, Kelly M; Wijayawardana, Sameera R; Schade, Andrew E
2014-12-01
Development of novel targeted therapies directed against hepatocyte growth factor (HGF) or its receptor (MET) necessitates the availability of quality diagnostics to facilitate their safe and effective use. Limitations of some commercially available anti-MET antibodies have prompted development of the highly sensitive and specific clone A2H2-3. Here we report its analytical properties when applied by an automated immunohistochemistry method. Excellent antibody specificity was demonstrated by immunoblot, ELISA, and IHC evaluation of characterised cell lines including NIH3T3 overexpressing the related kinase MST1R (RON). Sensitivity was confirmed by measurements of MET in cell lines or characterised tissues. IHC correlated well with FISH and quantitative RT-PCR assessments of MET (P < 0.001). Good total agreement (89%) was observed with the anti-MET antibody clone SP44 using whole-tissue sections, but poor positive agreement (21-47%) was seen in tissue microarray cores. Multiple lots displayed appropriate reproducibility (R(2) > 0.9). Prevalence of MET positivity by IHC was higher in non-squamous cell NSCLC, MET or EGFR amplified cases, and in tumours harbouring abnormalities in EGFR exon 19 or 21. The anti-MET antibody clone A2H2-3 displays excellent specificity and sensitivity. These properties make it suitable for clinical trial investigations and development as a potential companion diagnostic. © 2014 The Authors. Histopathology Published by John Wiley & Sons Ltd.
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo
2017-01-01
Purpose To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). Methods 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. Results 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. Conclusions CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR. PMID:28042958
Poreba, Marcin; Szalek, Aleksandra; Rut, Wioletta; Kasperkiewicz, Paulina; Rutkowska-Wlodarczyk, Izabela; Snipas, Scott J.; Itoh, Yoshifumi; Turk, Dusan; Turk, Boris; Overall, Christopher M.; Kaczmarek, Leszek; Salvesen, Guy S.; Drag, Marcin
2017-01-01
Internally quenched fluorescent (IQF) peptide substrates originating from FRET (Förster Resonance Energy Transfer) are powerful tool for examining the activity and specificity of proteases, and a variety of donor/acceptor pairs are extensively used to design individual substrates and combinatorial libraries. We developed a highly sensitive and adaptable donor/acceptor pair that can be used to investigate the substrate specificity of cysteine proteases, serine proteases and metalloproteinases. This novel pair comprises 7-amino-4-carbamoylmethylcoumarin (ACC) as the fluorophore and 2,4-dinitrophenyl-lysine (Lys(DNP)) as the quencher. Using caspase-3, caspase-7, caspase-8, neutrophil elastase, legumain, and two matrix metalloproteinases (MMP2 and MMP9), we demonstrated that substrates containing ACC/Lys(DNP) exhibit 7 to 10 times higher sensitivity than conventional 7-methoxy-coumarin-4-yl acetic acid (MCA)/Lys(DNP) substrates; thus, substantially lower amounts of substrate and enzyme can be used for each assay. We therefore propose that the ACC/Lys(DNP) pair can be considered a novel and sensitive scaffold for designing substrates for any group of endopeptidases. We further demonstrate that IQF substrates containing unnatural amino acids can be used to investigate protease activities/specificities for peptides containing post-translationally modified amino acids. Finally, we used IQF substrates to re-investigate the P1-Asp characteristic of caspases, thus demonstrating that some human caspases can also hydrolyze substrates after glutamic acid. PMID:28230157
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo
2017-01-31
To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR.
Zhang, Y-N; Zhang, J; Yan, S-W; Chang, H-T; Liu, Y; Wang, G-R; Dong, S-L
2014-10-01
The sex pheromone communication system in moths is highly species-specific and extremely sensitive, and pheromone receptors (PRs) are thought to be the most important factors in males. In the present study, three full-length cDNAs encoding PRs were characterized from Sesamia inferens antennae. These three PRs were all male-specific in expression, but their relative expression levels were very different; SinfOR29 was 17- to 23-fold higher than the other two PRs. Phylogenetic and motif pattern analyses showed that these three PRs were allocated to different PR subfamilies with different motif patterns. Functional analysis using the heterologous expression system of Xenopus oocytes demonstrated that SinfOR29 specifically and sensitively responded to the major pheromone component, Z11-16:OAc [concentration for 50% of maximal effect (EC50 ) = 3.431 × 10(-7) M], while SinfOR21 responded robustly to a minor pheromone component Z11-16:OH (EC50 = 1.087 × 10(-6) M). SinfOR27, however, displayed no response to any of the three pheromone components, but, interestingly, it was sensitive to a non-sex pheromone component Z9,E12-14:OAc (EC50 = 1.522 × 10(-6) M). Our results provide insight into the molecular mechanisms of specificity and sensitivity of the sex pheromone communication system in moths. © 2014 The Royal Entomological Society.
Jiang, Wen Jun; Wittek, Peter; Zhao, Li; Gao, Shi Chao
2014-01-01
Photoplethysmogram (PPG) signals acquired by smartphone cameras are weaker than those acquired by dedicated pulse oximeters. Furthermore, the signals have lower sampling rates, have notches in the waveform and are more severely affected by baseline drift, leading to specific morphological characteristics. This paper introduces a new feature, the inverted triangular area, to address these specific characteristics. The new feature enables real-time adaptive waveform detection using an algorithm of linear time complexity. It can also recognize notches in the waveform and it is inherently robust to baseline drift. An implementation of the algorithm on Android is available for free download. We collected data from 24 volunteers and compared our algorithm in peak detection with two competing algorithms designed for PPG signals, Incremental-Merge Segmentation (IMS) and Adaptive Thresholding (ADT). A sensitivity of 98.0% and a positive predictive value of 98.8% were obtained, which were 7.7% higher than the IMS algorithm in sensitivity, and 8.3% higher than the ADT algorithm in positive predictive value. The experimental results confirmed the applicability of the proposed method.
Cooper, K L; Meng, Y; Harnan, S; Ward, S E; Fitzgerald, P; Papaioannou, D; Wyld, L; Ingram, C; Wilkinson, I D; Lorenz, E
2011-01-01
Breast cancer is the most common type of cancer in women. Evaluation of axillary lymph node metastases is important for breast cancer staging and treatment planning. To evaluate the diagnostic accuracy, cost-effectiveness and effect on patient outcomes of positron emission tomography (PET), with or without computed tomography (CT), and magnetic resonance imaging (MRI) in the evaluation of axillary lymph node metastases in patients with newly diagnosed early-stage breast cancer. A systematic review of literature and an economic evaluation were carried out. Key databases (including MEDLINE, EMBASE and nine others) plus research registers and conference proceedings were searched for relevant studies up to April 2009. A decision-analytical model was developed to determine cost-effectiveness in the UK. One reviewer assessed titles and abstracts of studies identified by the search strategy, obtained the full text of relevant papers and screened them against inclusion criteria. Data from included studies were extracted by one reviewer using a standardised data extraction form and checked by a second reviewer. Discrepancies were resolved by discussion. Quality of included studies was assessed using the quality assessment of diagnostic accuracy studies (QUADAS) checklist, applied by one reviewer and checked by a second. Forty-five citations relating to 35 studies were included in the clinical effectiveness review: 26 studies of PET and nine studies of MRI. Two studies were included in the cost-effectiveness review: one of PET and one of MRI. Of the seven studies evaluating PET/CT (n = 862), the mean sensitivity was 56% [95% confidence interval (CI) 44% to 67%] and mean specificity 96% (95% CI 90% to 99%). Of the 19 studies evaluating PET only (n = 1729), the mean sensitivity was 66% (95% CI 50% to 79%) and mean specificity 93% (95% CI 89% to 96%). PET performed less well for small metastases; the mean sensitivity was 11% (95% CI 5% to 22%) for micrometastases (≤ 2 mm; five studies; n = 63), and 57% (95% CI 47% to 66%) for macrometastases (> 2 mm; four studies; n = 111). The smallest metastatic nodes detected by PET measured 3 mm, while PET failed to detect some nodes measuring > 15 mm. Studies in which all patients were clinically node negative showed a trend towards lower sensitivity of PET compared with studies with a mixed population. Across five studies evaluating ultrasmall super-paramagnetic iron oxide (USPIO)-enhanced MRI (n = 93), the mean sensitivity was 98% (95% CI 61% to 100%) and mean specificity 96% (95% CI 72% to 100%). Across three studies of gadolinium-enhanced MRI (n = 187), the mean sensitivity was 88% (95% CI 78% to 94%) and mean specificity 73% (95% CI 63% to 81%). In the single study of in vivo proton magnetic resonance spectroscopy (n = 27), the sensitivity was 65% (95% CI 38% to 86%) and specificity 100% (95% CI 69% to 100%). USPIO-enhanced MRI showed a trend towards higher sensitivity and specificity than gadolinium-enhanced MRI. Results of the decision modelling suggest that the MRI replacement strategy is the most cost-effective strategy and dominates the baseline 4-node sampling (4-NS) and sentinel lymph node biopsy (SLNB) strategies in most sensitivity analyses undertaken. The PET replacement strategy is not as robust as the MRI replacement strategy, as its cost-effectiveness is significantly affected by the utility decrement for lymphoedema and the probability of relapse for false-negative (FN) patients. No included studies directly compared PET and MRI. Studies demonstrated that PET and MRI have lower sensitivity and specificity than SLNB and 4-NS but are associated with fewer adverse events. Included studies indicated a significantly higher mean sensitivity for MRI than for PET, with USPIO-enhanced MRI providing the highest sensitivity. However, sensitivity and specificity of PET and MRI varied widely between studies, and MRI studies were relatively small and varied in their methods; therefore, results should be interpreted with caution. Decision modelling based on these results suggests that the most cost-effective strategy may be MRI rather than SLNB or 4-NS. This strategy reduces costs and increases quality-adjusted life-years (QALYs) because there are fewer adverse events for the majority of patients. However, this strategy leads to more FN cases at higher risk of cancer recurrence and more false- positive (FP) cases who would undergo unnecessary axillary lymph node dissection. Adding MRI prior to SLNB or 4-NS has little effect on QALYs, though this analysis is limited by lack of available data. Future research should include large, well-conducted studies of MRI, particularly using USPIO; data on the long-term impacts of lymphoedema on cost and patient utility; studies of the comparative effectiveness and cost-effectiveness of SLNB and 4-NS; and more robust UK cost data for 4-NS and SLNB as well as the cost of MRI and PET techniques. This study was funded by the Health Technology Assessment programme of the National Institute of Health Research.
Paliwal, Shivani R; Paliwal, Rishi; Pal, Harish C; Saxena, Ajeet K; Sharma, Pradyumana R; Gupta, Prem N; Agrawal, Govind P; Vyas, Suresh P
2012-01-01
The present investigation reports the development of nanoengineered estrogen receptor (ER) targeted pH-sensitive liposome for the site-specific intracellular delivery of doxorubicin (DOX) for breast cancer therapy. Estrone, a bioligand, was anchored on the surface of pH-sensitive liposome for drug targeting to ERs. The estrone-anchored pH-sensitive liposomes (ES-pH-sensitive-SL) showed fusogenic potential at acidic pH (5.5). In vitro cytotoxicity studies carried out on ER-positive MCF-7 breast carcinoma cells revealed that ES-pH-sensitive-SL formulation was more cytotoxic than non-pH-sensitive targeted liposomes (ES-SL). The flow cytometry analysis confirmed significant enhanced uptake (p < 0.05) of ES-pH-sensitive-SL by MCF-7 cells. Intracellular delivery and nuclear localization of the DOX was confirmed by fluorescence microscopy. The mechanism for higher cytotoxicity shown by estrone-anchored pH-sensitive liposomal-DOX was elucidated using reactive oxygen species (ROS) determination. The in vivo biodistribution studies and antitumor activities of formulations were evaluated on tumor bearing female Balb/c mice followed by intravenous administration. The ES-pH-sensitive-SL efficiently suppressed the breast tumor growth in comparison to both ES-SL and free DOX. Serum enzyme activities such as LDH and CPK levels were assayed for the evaluation of DOX induced cardiotoxicity. The ES-pH-sensitive-SL accelerated the intracellular trafficking of encapsulated DOX, thus increasing the therapeutic efficacy. The findings support that estrone-anchored pH-sensitive liposomes could be one of the promising nanocarriers for the targeted intracellular delivery of anticancer agents to breast cancer with reduced systemic side effects.
Yokota, K; Yamaguchi, K; Takeshita, T; Morimoto, K
1998-06-01
A definitive role for allergen-specific IgG4 as either an anaphylactic or a blocking antibody, or both, remains controversial. A population of 148 workers from two condenser plants (A and B) using epoxy resin with methyltetrahydrophthalic anhydride (MTHPA) was studied to evaluate the significance of MTHPA-specific IgG4 antibody. The workers were evaluated through questionnaire and serological investigations. Ninety-seven (66%) of the currently exposed workers had positive MTHPA-specific IgE. IgE-sensitized workers in each plant had significantly more eye and nose complaints than unsensitized workers (P < 0.03). As the result of multiple logistic analysis, specific IgE antibodies was the most important predictor of work-related symptoms and its effect was greater than that of specific IgG4 (odds ratio 16.7 and 3.68, respectively). These indicate an IgE-mediated mechanism in most cases of work-related symptoms associated with MTHPA exposure. However, it cannot be denied that specific IgG4 is an anaphylactic antibody. Furthermore, IgE-sensitized workers in these plants displayed work-related symptoms despite the presence of specific IgG4. The frequency of positive specific IgG4 in continuously exposed workers was significantly (P < 0.02) higher in plant A than in plant B, reflecting the difference of the MTHPA levels between the two plants. In plant A, the frequency of positive specific IgG4 was significantly (P < 0.002) higher in continuously exposed workers than in intermittently exposed workers. Multiple regression analysis also confirmed that plant and exposure style contributed significantly (P < 0.01) to the determination of specific IgG4 levels. These results suggest that work-related eye and nasal symptoms are likely to be IgE-mediated, and that specific IgG4 may reflect the intensity of MTHPA exposure and may not act as a blocking antibody.
Gajewski, Z; Petrajtis-Gołobów, M; Melo de Sousa, N; Beckers, J F; Pawliński, B; Wehrend, A
2014-12-01
The aim of this study was to compare two methods of early pregnancy diagnosis by determining pregnancy-associated glycoprotein (PAG) concentration in blood and PAG concentration in milk. Blood and milk samples were obtained on days 0 (AI day), 14, 21, 28, 35, 49, 63, 77, 91 and 105 of gestation from 60 lactating Holstein Frisian cows from one herd, carrying live fetuses. To determine PAG concentration a specific RIA system (RIA-706) was used. PAG concentration in blood and milk increased after 28 days of pregnancy, with blood concentrations being significantly higher than in milk. However, the accuracy of both tests at this time point was similar (sensitivity: 92 % in blood, 93 % in milk; specificity 53 % and 60 % respectively). None of the tests were able to detect open cows properly at this stage. On day 35 of gestation sensitivity (100 % for blood, 97 % for milk) and specificity (100 % for blood, 100 % for milk) were high enough to be used for reliable pregnancy diagnosis. The accuracy (sensitivity and specificity) for PAG concentrations in blood and milk for the rest of the study was 100 %. Our investigation shows that PAG determination in milk is a stress-free and non-invasive method for early pregnancy diagnosis in cattle.
Interobserver variability of sonography for prediction of placenta accreta.
Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M
2014-12-01
The sensitivity of sonography to predict accreta has been reported as higher than 90%. However, most studies are from single expert investigators. Our objective was to analyze interobserver variability of sonography for prediction of placenta accreta. Patients with previa with and without accreta were ascertained, and images with placental views were collected, deidentified, and placed in random sequence. Three radiologists and 3 maternal-fetal medicine specialists interpreted each study for the presence of accreta and specific findings reported to be associated with its diagnosis. Investigator-specific sensitivity, specificity, and accuracy were calculated. κ statistics were used to assess variability between individuals and types of investigators. A total of 229 sonographic studies from 55 patients with accreta and 56 control patients were examined. Accuracy ranged from 55.9% to 76.4%. Of imaging studies yielding diagnoses, sensitivity ranged from 53.4% to 74.4%, and specificity ranged from 70.8% to 94.8%. Overall interobserver agreement was moderate (mean κ ± SD = 0.47 ± 0.12). κ values between pairs of investigators ranged from 0.32 (fair agreement) to 0.73 (substantial agreement). Average individual agreement ranged from fair (κ = 0.35) to moderate (κ = 0.53). Blinded from clinical data, sonography has significant interobserver variability for the diagnosis of placenta accreta. © 2013 by the American Institute of Ultrasound in Medicine.
Thiruppathiraja, Chinnasamy; Kamatchiammal, Senthilkumar; Adaikkappan, Periyakaruppan; Santhosh, Devakirubakaran Jayakar; Alagar, Muthukaruppan
2011-10-01
The present study was aimed at the development and evaluation of a DNA electrochemical biosensor for Mycobacterium sp. genomic DNA detection in a clinical specimen using a signal amplifier as dual-labeled AuNPs. The DNA electrochemical biosensors were fabricated using a sandwich detection strategy involving two kinds of DNA probes specific to Mycobacterium sp. genomic DNA. The probes of enzyme ALP and the detector probe both conjugated on the AuNPs and subsequently hybridized with target DNA immobilized in a SAM/ITO electrode followed by characterization with CV, EIS, and DPV analysis using the electroactive species para-nitrophenol generated by ALP through hydrolysis of para-nitrophenol phosphate. The effect of enhanced sensitivity was obtained due to the AuNPs carrying numerous ALPs per hybridization and a detection limit of 1.25 ng/ml genomic DNA was determined under optimized conditions. The dual-labeled AuNP-facilitated electrochemical sensor was also evaluated by clinical sputum samples, showing a higher sensitivity and specificity and the outcome was in agreement with the PCR analysis. In conclusion, the developed electrochemical sensor demonstrated unique sensitivity and specificity for both genomic DNA and sputum samples and can be employed as a regular diagnostics tool for Mycobacterium sp. monitoring in clinical samples. Copyright © 2011 Elsevier Inc. All rights reserved.
Jin, Chenggang; Roen, Diana R.; Lehmann, Paul V.; Kellermann, Gottfried H.
2013-01-01
Lyme Borreliosis is an infectious disease caused by the spirochete Borrelia burgdorferi that is transmitted through the bite of infected ticks. Both B cell-mediated humoral immunity and T cell immunity develop during natural Borrelia infection. However, compared with humoral immunity, the T cell response to Borrelia infection has not been well elucidated. In this study, a novel T cell-based assay was developed and validated for the sensitive detection of antigen-specific T cell response to B. burgdorferi. Using interferon-γ as a biomarker, we developed a new enzyme-linked immunospot method (iSpot LymeTM) to detect Borrelia antigen-specific effector/memory T cells that were activated in vivo by exposing them to recombinant Borrelia antigens ex vivo. To test this new method as a potential laboratory diagnostic tool, we performed a clinical study with a cohort of Borrelia positive patients and healthy controls. We demonstrated that the iSpot Lyme assay has a significantly higher specificity and sensitivity compared with the Western Blot assay that is currently used as a diagnostic measure. A comprehensive evaluation of the T cell response to Borrelia infection should, therefore, provide new insights into the pathogenesis, diagnosis, treatment and monitoring of Lyme disease. PMID:24709800
Yousefi-Nooraie, Reza; Irani, Shirin; Mortaz-Hedjri, Soroush; Shakiba, Behnam
2013-10-01
The aim of this study was to compare the performance of three search methods in the retrieval of relevant clinical trials from PubMed to answer specific clinical questions. Included studies of a sample of 100 Cochrane reviews which recorded in PubMed were considered as the reference standard. The search queries were formulated based on the systematic review titles. Precision, recall and number of retrieved records for limiting the results to clinical trial publication type, and using sensitive and specific clinical queries filters were compared. The number of keywords, presence of specific names of intervention and syndrome in the search keywords were used in a model to predict the recalls and precisions. The Clinical queries-sensitive search strategy retrieved the largest number of records (33) and had the highest recall (41.6%) and lowest precision (4.8%). The presence of specific intervention name was the only significant predictor of all recalls and precisions (P = 0.016). The recall and precision of combination of simple clinical search queries and methodological search filters to find clinical trials in various subjects were considerably low. The limit field strategy yielded in higher precision and fewer retrieved records and approximately similar recall, compared with the clinical queries-sensitive strategy. Presence of specific intervention name in the search keywords increased both recall and precision. © 2010 John Wiley & Sons Ltd.
Molecular diagnosis and immunotherapy.
Sastre, Joaquín; Sastre-Ibañez, Marina
2016-12-01
To describe recent insights into how molecular diagnosis can improve indication and selection of suitable allergens for specific immunotherapy and increase the safety of this therapy. As specific allergen immunotherapy targets specific allergens, identification of the disease-eliciting allergen is a prerequisite for accurate prescription of treatment. In areas of complex sensitization to aeroallergens or in cases of hymenoptera venom allergy, the use of molecular diagnosis has demonstrated that it may lead to a change in indication and selection of allergens for immunotherapy in a large proportion of patients when compared with diagnosis based on skin prick testing and/or specific IgE determination with commercial extracts. These changes in immunotherapy prescription aided by molecular diagnosis have been demonstrated to be cost-effective in some scenarios. Certain patterns of sensitization to grass or olive pollen and bee allergens may identify patients with higher risk of adverse reaction during immunotherapy. Molecular diagnosis, when used with other tools and patients' clinical records, can help clinicians better to select the most appropriate patients and allergens for specific immunotherapy and, in some cases, predict the risk of adverse reactions. The pattern of sensitization to allergens could potentially predict the efficacy of allergen immunotherapy provided that these immunotherapy products contain a sufficient amount of these allergens. Nevertheless, multiplex assay remains a third-level approach, not to be used as screening method in current practice.
Measurement invariance versus selection invariance: is fair selection possible?
Borsboom, Denny; Romeijn, Jan-Willem; Wicherts, Jelte M
2008-06-01
This article shows that measurement invariance (defined in terms of an invariant measurement model in different groups) is generally inconsistent with selection invariance (defined in terms of equal sensitivity and specificity across groups). In particular, when a unidimensional measurement instrument is used and group differences are present in the location but not in the variance of the latent distribution, sensitivity and positive predictive value will be higher in the group at the higher end of the latent dimension, whereas specificity and negative predictive value will be higher in the group at the lower end of the latent dimension. When latent variances are unequal, the differences in these quantities depend on the size of group differences in variances relative to the size of group differences in means. The effect originates as a special case of Simpson's paradox, which arises because the observed score distribution is collapsed into an accept-reject dichotomy. Simulations show the effect can be substantial in realistic situations. It is suggested that the effect may be partly responsible for overprediction in minority groups as typically found in empirical studies on differential academic performance. A methodological solution to the problem is suggested, and social policy implications are discussed. (PsycINFO Database Record (c) 2008 APA, all rights reserved).
Manzanares-Laya, S; Burón, A; Murta-Nascimento, C; Servitja, S; Castells, X; Macià, F
2014-01-01
Hospital cancer registries and hospital databases are valuable and efficient sources of information for research into cancer recurrences. The aim of this study was to develop and validate algorithms for the detection of breast cancer recurrence. A retrospective observational study was conducted on breast cancer cases from the cancer registry of a third level university hospital diagnosed between 2003 and 2009. Different probable cancer recurrence algorithms were obtained by linking the hospital databases and the construction of several operational definitions, with their corresponding sensitivity, specificity, positive predictive value and negative predictive value. A total of 1,523 patients were diagnosed of breast cancer between 2003 and 2009. A request for bone gammagraphy after 6 months from the first oncological treatment showed the highest sensitivity (53.8%) and negative predictive value (93.8%), and a pathology test after 6 months after the diagnosis showed the highest specificity (93.8%) and negative predictive value (92.6%). The combination of different definitions increased the specificity and the positive predictive value, but decreased the sensitivity. Several diagnostic algorithms were obtained, and the different definitions could be useful depending on the interest and resources of the researcher. A higher positive predictive value could be interesting for a quick estimation of the number of cases, and a higher negative predictive value for a more exact estimation if more resources are available. It is a versatile and adaptable tool for other types of tumors, as well as for the needs of the researcher. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Yoon, Na Ri; Park, Jae Myung; Jung, Hee Sun; Cho, Yu Kyung; Lee, In Seok; Choi, Myung Gyu; Chung, In Sik; Song, Kyo Young; Park, Cho Hyun
2012-05-01
The usefulness of ¹⁸F-fluoro-2-deoxyglucose (FDG)-PET in detecting primary cancer, lymph node metastasis, and distant metastasis were studied in the gastric cancer patients. The subjects were 392 gastric cancer patients who received FDG-PET and an abdominal CT test prior to surgery. The results of FDG-PET and CT were compared with the surgical and pathologic results. The primary site detection rate of FDG-PET was 74.4%, 50.3% in early gastric cancer and 92.0% in advanced gastric cancer. Detection rate was higher when tumors were larger than 3.5 cm, had deeper depth of invasion, and at a later stage (p<0.05, respectively). In multivariate analysis, tumor size, spread of tumor cells beyond the muscle layer (≥T2), and lymph node metastasis were statistically significant factors in primary site detection rate. The sensitivity, specificity, and positive predictive value of FDG-PET to lymph node metastasis were 59.6%, 88.8%, and 81.1% respectively, sensitivity being lower compared to CT while specificity and positive predictive value were higher. Sensitivity, specificity, and positive predictive value to distant metastasis were, respectively, 66.7%, 99.2%, and 88.0%, similar to CT. In 21 of the 392 patients (5.4%), synchronous double primary cancers were detected. In gastric cancer, usefullness of FDG-PET is limited to the advanced stage. Diagnostic value of this test was not superior to CT. However, FDG-PET may be useful in detecting synchronous double primary cancers.
Neumann, K; Holler-Zittlau, I; van Minnen, S; Sick, U; Zaretsky, Y; Euler, H A
2011-01-01
The German Kindersprachscreening (KiSS) is a universal speech and language screening test for large-scale identification of Hessian kindergarten children requiring special educational language training or clinical speech/language therapy. To calculate the procedural screening validity, 257 children (aged 4.0 to 4.5 years) were tested using KiSS and four language tests (Reynell Development Language Scales III, Patholinguistische Diagnostik, PLAKSS, AWST-R). The majority or consensus judgements of three speech-language professionals, based on the language test results, served as a reference criterion. The base (fail) rates of the professionals were either self-determined or preset based on known prevalence rates. Screening validity was higher for preset than for self-determined base rates due to higher inter-judge agreement. The confusion matrices of the overall index classification of the KiSS (speech-language abnormalities with educational or clinical needs) with the fixed base rate expert judgement about language impairment, including fluency or voice disorders, yielded a sensitivity of 88% and a specificity of 78%, for just language impairment 84% and 75%, respectively. Specificities for disorders requiring clinical diagnostics in the KiSS (language impairment alone or combined with fluency/voice disorders) related to the test-based consensus expert judgment was about 93%. Sensitivities were unsatisfactory because the differentiation between educational and clinical needs requires improvement. Since the judgement concordances between the speech-language professionals was only moderate, the development of a comprehensive German reference test for speech and language disorders with evidence-based algorithmic decision rules rather than subjective clinical judgement is advocated.
Vajapeyam, S; Stamoulis, C; Ricci, K; Kieran, M; Poussaint, T Young
2017-01-01
Pharmacokinetic parameters from dynamic contrast-enhanced MR imaging have proved useful for differentiating brain tumor grades in adults. In this study, we retrospectively reviewed dynamic contrast-enhanced perfusion data from children with newly diagnosed brain tumors and analyzed the pharmacokinetic parameters correlating with tumor grade. Dynamic contrast-enhanced MR imaging data from 38 patients were analyzed by using commercially available software. Subjects were categorized into 2 groups based on pathologic analyses consisting of low-grade (World Health Organization I and II) and high-grade (World Health Organization III and IV) tumors. Pharmacokinetic parameters were compared between the 2 groups by using linear regression models. For parameters that were statistically distinct between the 2 groups, sensitivity and specificity were also estimated. Eighteen tumors were classified as low-grade, and 20, as high-grade. Transfer constant from the blood plasma into the extracellular extravascular space (K trans ), rate constant from extracellular extravascular space back into blood plasma (K ep ), and extracellular extravascular volume fraction (V e ) were all significantly correlated with tumor grade; high-grade tumors showed higher K trans , higher K ep , and lower V e . Although all 3 parameters had high specificity (range, 82%-100%), K ep had the highest specificity for both grades. Optimal sensitivity was achieved for V e , with a combined sensitivity of 76% (compared with 71% for K trans and K ep ). Pharmacokinetic parameters derived from dynamic contrast-enhanced MR imaging can effectively discriminate low- and high-grade pediatric brain tumors. © 2017 by American Journal of Neuroradiology.
Caba, L M; Ferrairó, J I T; Torres, I M; Costa, J F V; Muñoz, R B; Martin, A L
2017-12-29
The diagnosis of vascular parkinsonism (VP) is based on a series of clinical criteria and neuroimaging findings. An increase in transcranial Doppler ultrasonography pulsatility index (PI) has been described as a frequent finding in patients with VP. We aimed to confirm this association and to determine the PI value with the highest sensitivity and specificity for diagnosis of VP. PI was determined in all patients admitted to Hospital Universitari i Politècnic La Fe due to parkinsonism between January 2012 and June 2016. We assessed the probability of having VP based on PI values in patients with a definite diagnosis of either VP or idiopathic Parkinson's disease (IPD). A ROC curve was created to determine the PI value with the highest sensitivity and specificity. We assessed a total of 146 patients with suspected parkinsonism; 54 (37%) were diagnosed with IPD and 15 (10%) with VP. Patients with VP were significantly older than those with IPD (mean age of 79 vs 68.5, P=.00144) and had a higher PI (median of 1.29 [IQR: 1.09-1.38] vs 0.96 [IQR: 0.89-1.16], P=.01328). In our sample, a PI of 1.09 conferred 84% sensitivity and 70% specificity. In our series, the PI was significantly higher in patients with VP than in those with IPD. We therefore support the use of transcranial Doppler ultrasonography for the initial assessment of elderly patients with akinetic-rigid syndrome. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Comparing sensitivity and specificity of screening mammography in the United States and Denmark
Jacobsen, Katja Kemp; O'Meara, Ellen S.; Key, Dustin; Buist, Diana SM; Kerlikowske, Karla; Vejborg, Ilse; Sprague, Brian L.; Lynge, Elsebeth; von Euler-Chelpin, My
2015-01-01
Delivery of screening mammography differs substantially between the United States (US) and Denmark. We evaluate whether there are differences in screening sensitivity and specificity. We included screens from women screened at age 50-69 years during 1996-2008/2009 in the US Breast Cancer Surveillance Consortium (BCSC) (n=2,872,791), and from two population-based mammography screening programs in Denmark (Copenhagen, n=148,156 and Funen, n=275,553). Women were followed for one year. For initial screens, recall rate was significantly higher in BCSC (17.6%) than in Copenhagen (4.3%) and Funen (3.1%). Sensitivity was fairly similar in BCSC (91.8%) and Copenhagen (90.5%) and Funen (92.5%). At subsequent screens, recall rates were 8.8%, 1.8% and 1.4% in BCSC, Copenhagen and Funen, respectively. The BCSC sensitivity (82.3%) was lower compared to Copenhagen (88.9%) and Funen (86.9%), but when stratified by time since last screen, the sensitivity was similar. For both initial and subsequent screening, the specificity of screening in BCSC (83.2 and 91.6%) was significantly lower than in Copenhagen (96.6 and 98.8%) and Funen. (97.9 and 99.2%). Taking time since last screen into account, American and Danish women had the same probability of having their asymptomatic cancers detected at screening. However, the majority of women free of asymptomatic cancers experienced more harms in terms of false-positive findings in the US than in Denmark. PMID:25944711
Yang, Weijuan; Zhang, Hongyan; Li, Mengxue; Wang, Zonghua; Zhou, Jie; Wang, Shihua; Lu, Guodong; Fu, FengFu
2014-11-19
As one of the most destructive and widespread disease of rice, Magnaporthe oryzae (also called Magnaporthe grisea) has a significant negative impact on rice production. Therefore, it is still in high demand to develop extremely sensitive and accurate methods for the early diagnosis of Magnaporthe oryzae (M. oryzae). In this study, we developed a novel magnetic-controllable electrochemical biosensor for the ultra sensitive and specific detection of M. oryzae in rice plant by using M. oryzae's chitinases (Mgchi) as biochemical marker and a rice (Oryza sativa) cDNA encoding mannose-binding jacalin-related lectin (Osmbl) as recognition probe. The proposed biosensor combined with the merits of chronoamperometry, electrically magnetic-controllable gold electrode and magnetic beads (MBs)-based palladium nano-particles (PdNPs) catalysis amplification, has an ultra-high sensitivity and specificity for the detection of trace M. oryzae in rice plant. It could be used to detect M. oryzae in rice plant in the initial infection stage (before any symptomatic lesions were observed) to help farmers timely manage the disease. In comparison with previous methods, the proposed method has notable advantages such as higher sensitivity, excellent specificity, short analysis time, robust resistibility to complex matrix and low cost etc. The success in this study provides a reliable approach for the early diagnosis and fast screening of M. oryzae in rice plant. Copyright © 2014 Elsevier B.V. All rights reserved.
Diagnostic value of prostate-specific antigen in women with polycystic ovary syndrome.
Mardanian, Farahnaz; Heidari, Nasrin
2011-08-01
Polycystic ovary syndrome (PCOS) is the most common endocrine disorder in women. Its presentation is that of irregular menstruation associated with ovulation defects. Because of adverse outcomes such as metabolic and cardiovascular disorders, its diagnosis and treatment is very important. Therefore, the diagnostic value of prostatespecific antigen (PSA) in women with polycystic ovary syndrome was evaluated. A total of 32 women with PCOS and 32 aged matched healthy females were recruited in this case-control study. The subjects were compared by means of metabolic measures and serum PSA level. The correlations between these markers were evaluated. Sensitivity and specificity values and cut off levels of PSA were established for diagnosis of PCOS. Mean PSA, Ferriman Gallwey score (FGS), luteinizing hormone/follicle stimulating hormone ratio (LH/FSH), testosterone, dehydroepiandrosterone sulfate (DHEAS), 17(α) hydroxyprogesterone (17(α) HP) levels were significantly higher in PCOS (P<0.001, respectively). PSA levels greater than 0.07 ng/ml yielded a sensitivity of 91% and specificity of 82%, and was helpful as a diagnostic tool for women with PCOS. Circulating androgens and hirsutism were associated with higher levels of PSA in PCOS women. Our results showed direct correlation between PSA, hirsutism and hyperandrogemsm state. Therefore, it seems logical to use PSA level for detection of hyperandrogemsm state in women.
Chandra, Amaresh; Keizerweerd, Amber T; Que, Youxiong; Grisham, Michael P
2015-08-01
Red rot, caused by Colletotrichum falcatum, is a destructive disease prevalent in most sugarcane-producing countries. Disease-free sugarcane planting materials (setts) are essential as the pathogen spreads primarily through infected setts. The present study was undertaken to develop a loop-mediated isothermal amplification (LAMP) assay for the detection of C. falcatum. C. falcatum genomic DNA was isolated from pure mycelium culture and infected tissues. Four sets of primers corresponding to a unique DNA sequence specific to C. falcatum were designed. Specificity of the LAMP test was checked with DNA of another fungal pathogen of sugarcane, Puccinia melanocephala, as well as two closely-related species, Colletotrichum fructivorum and Colletotrichum acutatum. No reaction was found with the three pathogens. When C. falcatum DNA from pure culture was used in a detection limit analysis, sensitivity of the LAMP method was observed to be ten times higher than that of conventional PCR; however, sensitivity was only 5 times higher when DNA from C. falcatum-infected tissues was used. Using the LAMP assay, C. falcatum DNA is amplified with high specificity, efficiency, and rapidity under isothermal conditions. Moreover, visual judgment of color change in <1 h without further post-amplification processing makes the LAMP method convenient, economical, and useful in diagnostic laboratories and the field.
Label-free imaging and spectroscopy for early detection of cervical cancer.
Jing, Yueyue; Wang, Yulan; Wang, Xinyi; Song, Chuan; Ma, Jiong; Xie, Yonghui; Fei, Yiyan; Zhang, Qinghua; Mi, Lan
2018-05-01
The label-free imaging and spectroscopy method was studied on cervical unstained tissue sections obtained from 36 patients. The native fluorescence spectra of tissues are analyzed by the optical redox ratio (ORR), which is defined as fluorescence intensity ratio between NADH and FAD, and indicates the metabolism change with the cancer development. The ORRs of normal tissues are consistently higher than those of precancer or cancerous tissues. A criterion line of ORR at 5.0 can be used to discriminate cervical precancer/cancer from normal tissues. The sensitivity and specificity of the native fluorescence spectroscopy method for cervical cancer diagnosis are determined as 100% and 91%. Moreover, the native fluorescence spectroscopy study is much more sensitive on the healthy region of cervical precancer/cancer patients compared with the traditional clinical staining method. The results suggest label-free imaging and spectroscopy is a fast, highly sensitive and specific method on the detection of cervical cancer. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kennedy, Mark; Betts, Lucy R; Underwood, Jean D M
2014-01-01
Attachment theory asserts that secure attachment representations are developed through sensitive and consistent caregiving. If sensitive caregiving is a constant characteristic of the parent, then siblings should have concordant attachment classifications. The authors explored maternal attachment quality assessed by the Attachment Q-Set, maternal sensitivity, and specific mother-child interactions between siblings. Hour-long observations took place in the homes of 9 preschool sibling pairs and their immediate caregivers. The interactions were analyzed using a modified version of Bales' Small Group Analysis. The results reveal attachment discordance in a third of sibling pairs. While maternal sensitivity was higher with older siblings and mothers displayed more positive emotions when interacting with their younger siblings, attachment quality was not associated with birth order. Therefore, a shift toward a more contextual, family-based perspective of attachment is recommended to further understand how attachment strategies are created and maintained within the child's everyday context.
O'Leary, Helen; Smart, Keith M; Moloney, Niamh A; Blake, Catherine; Doody, Catherine M
2018-05-22
In knee osteoarthritis (OA) pain sensitization has been linked to a more severe symptomatology, but the prognostic implications of pain sensitivity in people undergoing conservative treatment such as physiotherapy are not established. This study aimed to prospectively investigate the association between features of pain sensitization and clinical outcome (non-response) following guideline-based physiotherapy in people with knee OA. Participants (n=156) with moderate/severe knee OA were recruited from secondary care. All participants completed self-administered questionnaires and underwent quantitative sensory testing (QST) at baseline, thereby establishing subjective and objective measures of pain sensitization. Participants (n=134) were later classified following a physiotherapy intervention, using treatment responder criteria (responder/non-responder). QST data was reduced to a core set of latent variables using principal component analysis. A hierarchical logistic regression model was constructed to investigate if features related to pain sensitization predicted non-response after controlling for other known predictors of poor outcome in knee OA. Higher temporal summation (TS) (OR 2.00, 95% CI 1.23 to 3.27) and lower pressure pain thresholds (PPT) (OR 0.48, 95% CI 0.29 to 0.81) emerged as robust predictors of non-response following physiotherapy, along with a higher comorbidity score. The model demonstrated high sensitivity (87.8%) but modest specificity (52.3%). The independent relationship between pain sensitization and non-response may indicate an underlying explanatory association between neuroplastic changes in nociceptive processing and the maintenance of on-going pain and disability in knee OA pain. These preliminary results suggest interventions targeting pain sensitization may warrant future investigation in this population.
Tan, W Katherine; Hassanpour, Saeed; Heagerty, Patrick J; Rundell, Sean D; Suri, Pradeep; Huhdanpaa, Hannu T; James, Kathryn; Carrell, David S; Langlotz, Curtis P; Organ, Nancy L; Meier, Eric N; Sherman, Karen J; Kallmes, David F; Luetmer, Patrick H; Griffith, Brent; Nerenz, David R; Jarvik, Jeffrey G
2018-03-28
To evaluate a natural language processing (NLP) system built with open-source tools for identification of lumbar spine imaging findings related to low back pain on magnetic resonance and x-ray radiology reports from four health systems. We used a limited data set (de-identified except for dates) sampled from lumbar spine imaging reports of a prospectively assembled cohort of adults. From N = 178,333 reports, we randomly selected N = 871 to form a reference-standard dataset, consisting of N = 413 x-ray reports and N = 458 MR reports. Using standardized criteria, four spine experts annotated the presence of 26 findings, where 71 reports were annotated by all four experts and 800 were each annotated by two experts. We calculated inter-rater agreement and finding prevalence from annotated data. We randomly split the annotated data into development (80%) and testing (20%) sets. We developed an NLP system from both rule-based and machine-learned models. We validated the system using accuracy metrics such as sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). The multirater annotated dataset achieved inter-rater agreement of Cohen's kappa > 0.60 (substantial agreement) for 25 of 26 findings, with finding prevalence ranging from 3% to 89%. In the testing sample, rule-based and machine-learned predictions both had comparable average specificity (0.97 and 0.95, respectively). The machine-learned approach had a higher average sensitivity (0.94, compared to 0.83 for rules-based), and a higher overall AUC (0.98, compared to 0.90 for rules-based). Our NLP system performed well in identifying the 26 lumbar spine findings, as benchmarked by reference-standard annotation by medical experts. Machine-learned models provided substantial gains in model sensitivity with slight loss of specificity, and overall higher AUC. Copyright © 2018 The Association of University Radiologists. All rights reserved.
Malik, Rizwan; Belliveau, Anne C; Sharpe, Glen P; Shuba, Lesya M; Chauhan, Balwantray C; Nicolela, Marcelo T
2016-06-01
Ruling out glaucoma in myopic eyes often poses a diagnostic challenge because of atypical optic disc morphology and visual field defects that can mimic glaucoma. We determined whether neuroretinal rim assessment based on Bruch's membrane opening (BMO), rather than conventional optic disc margin (DM)-based assessment or retinal nerve fiber layer (RNFL) thickness, yielded higher diagnostic accuracy in myopic patients with glaucoma. Case-control, cross-sectional study. Myopic patients with glaucoma (n = 56) and myopic normal controls (n = 74). Myopic subjects with refraction error greater than -2 diopters (D) (spherical equivalent) and typical myopic optic disc morphology, with and without glaucoma, were recruited from a glaucoma clinic and a local optometry practice. The final classification of myopic glaucoma or myopic control was based on consensus assessment by 3 clinicians of visual fields and optic disc photographs. Participants underwent imaging with confocal scanning laser tomography for measurement of DM rim area (DM-RA) and with spectral domain optical coherence tomography (SD OCT) for quantification of a BMO-based neuroretinal rim parameter, minimum rim width (BMO-MRW), and RNFL thickness. Sensitivity of DM-RA, BMO-MRW, and RNFL thickness at a fixed specificity of 90% and partial area under the curves (pAUCs) for global and sectoral parameters for specificities ≥90%. Sensitivities at 90% specificity were 30% for DM-RA and 71% for both BMO-MRW and RNFL thickness. The pAUC was higher for the BMO-MRW compared with DM-RA (P < 0.001), but similar to RNFL thickness (P > 0.5). Sectoral values of BMO-MRW tended to have a higher, but nonsignificant, pAUC across all sectors compared with RNFL thickness. Bruch's membrane opening MRW is more sensitive than DM-RA and similar to RNFL thickness for the identification of glaucoma in myopic eyes and offers a valuable diagnostic tool for patients with glaucoma with myopic optic discs. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Gijsberts, C M; Seneviratna, A; Bank, I E M; den Ruijter, H M; Asselbergs, F W; Agostoni, P; Remijn, J A; Pasterkamp, G; Kiat, H C; Roest, M; Richards, A M; Chan, M Y; de Kleijn, D P V; Hoefer, I E
2016-03-01
Risk factor burden and clinical characteristics of patients with coronary artery disease (CAD) differ among ethnic groups. We related biomarkers to CAD severity in Caucasians, Chinese, Indians and Malays. In the Dutch-Singaporean UNICORN coronary angiography cohort (n = 2033) we compared levels of five cardiovascular biomarkers: N-terminal pro-brain natriuretic peptide (NTproBNP), high-sensitivity C-reactive protein (hsCRP), cystatin C (CysC), myeloperoxidase (MPO) and high-sensitivity troponin I (hsTnI). We assessed ethnicity-specific associations of biomarkers with CAD severity, quantified by the SYNTAX score. Adjusted for baseline differences, NTproBNP levels were significantly higher in Malays than in Chinese and Caucasians (72.1 vs. 34.4 and 41.1 pmol/l, p < 0.001 and p = 0.005, respectively). MPO levels were higher in Caucasians than in Indians (32.8 vs. 27.2 ng/ml, p = 0.026), hsTnI levels were higher in Malays than in Caucasians and Indians (33.3 vs. 16.4 and 17.8 ng/l, p < 0.001 and p = 0.029) and hsTnI levels were higher in Chinese than in Caucasians (23.3 vs. 16.4, p = 0.031). We found modifying effects of ethnicity on the association of biomarkers with SYNTAX score. NTproBNP associated more strongly with the SYNTAX score in Malays than Caucasians (β 0.132 vs. β 0.020 per 100 pmol/l increase in NTproBNP, p = 0.032). For MPO levels the association was stronger in Malays than Caucasians (β 1.146 vs. β 0.016 per 10 ng/ml increase, p = 0.017). Differing biomarker cut-off levels were found for the ethnic groups. When corrected for possible confounders we observe ethnicity-specific differences in biomarker levels. Moreover, biomarkers associated differently with CAD severity, suggesting that ethnicity-specific cut-off values should be considered.
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.
Carrillo, Sergio A; Daniel, Vincent C; Hall, Nathan; Hitchcock, Charles L; Ross, Patrick; Kassis, Edmund S
2012-05-01
The 5-year survival for patients with resected stage II (N1) non-small cell lung cancer ranges from 40% to 55%. No data exist addressing the benefit of neoadjuvant therapy for patients with stage II disease. This is largely in part due to the lack of a reliable, minimally invasive method to assess hilar nodes. This study is aimed at determining the ability of fusion positron emission/computed tomography (PET/CT) to identify hilar metastases in patients with resected non-small cell lung cancer. A retrospective review of surgically resected patients with fusion PET/CT within 30 days of resection was performed. The sensitivity, specificity, positive predictive value, and negative predictive value for PET/CT in detecting hilar nodal metastases was calculated for a range of maximum standardized uptake values (SUVmax). Hilar nodes from patients with falsely positive PET/CT scans were analyzed for the presence of histoplasmosis. Additionally, the impact of hilar node size greater than 1 centimeter on the calculated values was assessed. There were 119 patients evaluated. The number of lymph nodes resected ranged from 1 to 12 (X=2.98). There was decreased sensitivity and increased specificity with higher SUVmax cutoff values. At the standard SUVmax value of 2.5, the sensitivity and specificity were only 48.5% and 80.2%. The addition of size of hilar node by CT led to a modest improvement in sensitivity at all SUVmax cutoff values. Fusion PET/CT lacks sensitivity and specificity in identifying hilar nodal metastasis in patients with resected non-small cell lung cancer. Further prospective studies assessing the utility of PET/CT versus alternative sampling techniques are warranted. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B
2013-06-01
Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.
Yin, Yue-Ping; Chen, Xiang-Sheng; Wei, Wan-Hui; Gong, Kuang-Long; Cao, Wen-Ling; Yong, Gang; Feng, Liang; Huang, Shu-Jie; Wang, Dong-Mei; Han, Yan; Chen, Shao-Chun; Mabey, David; Peeling, Rosanna W.
2013-01-01
Background. Rapid point-of-care (POC) syphilis tests based on simultaneous detection of treponemal and nontreponemal antibodies (dual POC tests) offer the opportunity to increase coverage of syphilis screening and treatment. This study aimed to conduct a multisite performance evaluation of a dual POC syphilis test in China. Methods. Participants were recruited from patients at sexually transmitted infection clinics and high-risk groups in outreach settings in 6 sites in China. Three kinds of specimens (whole blood [WB], fingerprick blood [FB], and blood plasma [BP]) were used for evaluating sensitivity and specificity of the Dual Path Platform (DPP) Syphilis Screen and Confirm test using its treponemal and nontreponemal lines to compare Treponema pallidum particle agglutination (TPPA) assay and toluidine red unheated serum test (TRUST) as reference standards. Results. A total of 3134 specimens (WB 1323, FB 488, and BP 1323) from 1323 individuals were collected. The sensitivities as compared with TPPA were 96.7% for WB, 96.4% for FB, and 94.6% for BP, and the specificities were 99.3%, 99.1%, and 99.6%, respectively. The sensitivities as compared with TRUST were 87.2% for WB, 85.8% for FB, and 88.4% for BP, and the specificities were 94.4%, 96.1%, and 95.0%, respectively. For specimens with a TRUST titer of 1:4 or higher, the sensitivities were 100.0% for WB, 97.8% for FB, and 99.6% for BP. Conclusions. DPP test shows good sensitivity and specificity in detecting treponemal and nontreponemal antibodies in 3 kinds of specimens. It is hoped that this assay can be considered as an alternative in the diagnosis of syphilis, particularly in resource-limited areas. PMID:23132172
Evaluation of Visual Field Progression in Glaucoma: Quasar Regression Program and Event Analysis.
Díaz-Alemán, Valentín T; González-Hernández, Marta; Perera-Sanz, Daniel; Armas-Domínguez, Karintia
2016-01-01
To determine the sensitivity, specificity and agreement between the Quasar program, glaucoma progression analysis (GPA II) event analysis and expert opinion in the detection of glaucomatous progression. The Quasar program is based on linear regression analysis of both mean defect (MD) and pattern standard deviation (PSD). Each series of visual fields was evaluated by three methods; Quasar, GPA II and four experts. The sensitivity, specificity and agreement (kappa) for each method was calculated, using expert opinion as the reference standard. The study included 439 SITA Standard visual fields of 56 eyes of 42 patients, with a mean of 7.8 ± 0.8 visual fields per eye. When suspected cases of progression were considered stable, sensitivity and specificity of Quasar, GPA II and the experts were 86.6% and 70.7%, 26.6% and 95.1%, and 86.6% and 92.6% respectively. When suspected cases of progression were considered as progressing, sensitivity and specificity of Quasar, GPA II and the experts were 79.1% and 81.2%, 45.8% and 90.6%, and 85.4% and 90.6% respectively. The agreement between Quasar and GPA II when suspected cases were considered stable or progressing was 0.03 and 0.28 respectively. The degree of agreement between Quasar and the experts when suspected cases were considered stable or progressing was 0.472 and 0.507. The degree of agreement between GPA II and the experts when suspected cases were considered stable or progressing was 0.262 and 0.342. The combination of MD and PSD regression analysis in the Quasar program showed better agreement with the experts and higher sensitivity than GPA II.
Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification
Oh, Kyudam; Pak, Nikita; Saunders, D. Curtis; Conrardy, Christina; Landers, James P.; Tong, Suxiang; Forest, Craig R.
2016-01-01
Sensitive identification of the etiology of viral diseases is key to implementing appropriate prevention and treatment. The gold standard for virus identification is the polymerase chain reaction (PCR), a technique that allows for highly specific and sensitive detection of pathogens by exponentially amplifying a specific region of DNA from as little as a single copy through thermocycling a biochemical cocktail. Today, molecular biology laboratories use commercial instruments that operate in 0.5–2 h/analysis using reaction volumes of 5–50 μL contained within polymer tubes or chambers. Towards reducing this volume and maintaining performance, we present a semi-quantitative, systematic experimental study of how PCR yield is affected by tube/chamber substrate, surface-area-to-volume ratio (SA:V), and passivation methods. We perform PCR experiments using traditional PCR tubes as well as using disposable polymer microchips with 1 μL reaction volumes thermocycled using water baths. We report the first oil encapsulation microfluidic PCR method without fluid flow and its application to the first microfluidic amplification of Epstein Barr virus using consensus degenerate primers, a powerful and broad PCR method to screen for both known and novel members of a viral family. The limit of detection is measured as 140 starting copies of DNA from a starting concentration of 3×105 copies/mL, regarded as an accepted sensitivity threshold for diagnostic purposes, and reaction specificity was improved as compared to conventional methods. Also notable, these experiments were conducted with conventional reagent concentrations, rather than commonly spiked enzyme and/or template mixtures. This experimental study of the effects of substrate, SA:V, and passivation, together with sensitive and specific microfluidic PCR with consensus degenerate primers represent advances towards lower cost and higher throughput pathogen screening. PMID:23080522
NASA Astrophysics Data System (ADS)
Vartsky, David; Goldberg, Mark B.; Engler, Gideon; Shor, Asher; Goldschmidt, Aharon; Feldman, Gennady; Bar, Doron; Orion, Itzhak; Wielopolski, Lucian
2004-01-01
Gamma-Ray Resonant Absorption (GRA) is an automatic-decision radiographic screening technique that combines high radiation penetration with very good sensitivity and specificity to nitrogenous explosives. The method is particularly well-suited to inspection of large, massive objects (since the resonant γ-ray probe is at 9.17 MeV) such as aviation and marine containers, heavy vehicles and railroad cars. Two kinds of γ-ray detectors have been employed to date in GRA systems: 1) Resonant-response nitrogen-rich liquid scintillators and 2) BGO detectors. This paper analyses and compares the response of these detector-types to the resonant radiation, in terms of single-pixel figures of merit. The latter are sensitive not only to detector response, but also to accelerator-beam quality, via the properties of the nuclear reaction that produces the resonant-γ-rays. Generally, resonant detectors give rise to much higher nitrogen-contrast sensitivity in the radiographic image than their non-resonant detector counterparts and furthermore, do not require proton beams of high energy-resolution. By comparison, the non-resonant detectors have higher γ-detection efficiency, but their contrast sensitivity is very sensitive to the quality of the accelerator beam. Implications of these detector/accelerator characteristics for eventual GRA field systems are discussed.
Dixon, Eric A.; Benham, Grant; Sturgeon, John A.; Mackey, Sean; Johnson, Kevin A.; Younger, Jarred
2016-01-01
Sensory hypersensitivity is one manifestation of the central sensitization that may underlie conditions such as fibromyalgia and chronic fatigue syndrome. We conducted five studies designed to develop and validate the Sensory Hypersensitive Scale (SHS); a 25-item self-report measure of sensory hypersensitivity. The SHS assesses both general sensitivity and modality-specific sensitivity (e.g. touch, taste, and hearing). 1202 participants (157 individuals with chronic pain) completed the SHS, which demonstrated an adequate overall internal reliability (Cronbach’s alpha) of 0.81, suggesting the tool can be used as a cross-modality assessment of sensitivity. SHS scores demonstrated only modest correlations (Pearson’s r) with depressive symptoms (0.19) and anxiety (0.28), suggesting a low level of overlap with psychiatric complaints. Overall SHS scores showed significant but relatively modest correlations (Pearson’s r) with three measures of sensory testing: cold pain tolerance (−0.34); heat pain tolerance (−0.285); heat pain threshold (−0.271). Women reported significantly higher scores on the SHS than did men, although gender-based differences were small. In a chronic pain sample, individuals with fibromyalgia syndrome demonstrated significantly higher SHS scores than did individuals with osteoarthritis or back pain. The SHS appears suitable as a screening measure for sensory hypersensitivity, though additional research is warranted to determine its suitability as a proxy for central sensitization. PMID:26873609
Multiparametric plasma EV profiling facilitates diagnosis of pancreatic malignancy.
Yang, Katherine S; Im, Hyungsoon; Hong, Seonki; Pergolini, Ilaria; Del Castillo, Andres Fernandez; Wang, Rui; Clardy, Susan; Huang, Chen-Han; Pille, Craig; Ferrone, Soldano; Yang, Robert; Castro, Cesar M; Lee, Hakho; Del Castillo, Carlos Fernandez; Weissleder, Ralph
2017-05-24
Pancreatic ductal adenocarcinoma (PDAC) is usually detected late in the disease process. Clinical workup through imaging and tissue biopsies is often complex and expensive due to a paucity of reliable biomarkers. We used an advanced multiplexed plasmonic assay to analyze circulating tumor-derived extracellular vesicles (tEVs) in more than 100 clinical populations. Using EV-based protein marker profiling, we identified a signature of five markers (PDAC EV signature) for PDAC detection. In our prospective cohort, the accuracy for the PDAC EV signature was 84% [95% confidence interval (CI), 69 to 93%] but only 63 to 72% for single-marker screening. One of the best markers, GPC1 alone, had a sensitivity of 82% (CI, 60 to 95%) and a specificity of 52% (CI, 30 to 74%), whereas the PDAC EV signature showed a sensitivity of 86% (CI, 65 to 97%) and a specificity of 81% (CI, 58 to 95%). The PDAC EV signature of tEVs offered higher sensitivity, specificity, and accuracy than the existing serum marker (CA 19-9) or single-tEV marker analyses. This approach should improve the diagnosis of pancreatic cancer. Copyright © 2017, American Association for the Advancement of Science.
Müller, Matthias J; Müller, Kay-Maria; Fellgiebel, Andreas
2006-05-01
To compare the psychometric properties of the Calgary Depression Rating Scale (CDRS) and the Hamilton Depression Rating Scale (HDRS) for severity assessment of depression in acute schizophrenia. During clinical routine treatment, we investigated 119 inpatients with acute schizophrenia, using the CDRS, the HDRS, and a global 4-point Depression Severity Scale (DEP-SEV). We compared CDRS and HDRS sum scores regarding their diagnostic accuracy, with global severity of depression as the criterion. We estimated sensitivity and specificity on the basis of receiver operating characteristic curves. According to global clinical ratings (DEP-SEV), 31% of patients had no depression, 19% had mild, 31% had moderate, and 19% had severe depression. Sensitivity was significantly higher (P < 0.05) for the CDRS than for the HDRS to assess mild (0.94 vs 0.76, cut-off 3 vs 10 points) or severe depression (1.00 vs 0.78, cut-off 11 vs 22 points); specificity was comparably high (> or = 0.88) for both scales. Despite the fact that both scales were effective in separating mild, moderate, and severe depression, significant advantages emerged for the CDRS to detect mild or severe depression in schizophrenia.
[Modernized study on eye's signs of blood-stasis syndrome].
Wu, Rui; Xie, Jian-xiang; Zhao, Feng-da
2011-03-01
To make out a computerized formula to diagnose eye's signs of blood-stasis syndrome (BSS), and to improve the previous diagnostic methods by naked eyes. The formula was created by detecting and analyzing the changes of eye's signs in 544 patients (261 of non-BSS and 283 of BSS) quantitatively, adopting computer's color scale principle. And the sensitivity, specificity and accuracy of the formula were verified in 382 patients (97 non-BSS and 285 of BSS). The computerized integral was compared with the naked eye integral, and the normal reference value was calculated with percentile. Various observatory indices of eye's sign were positively correlated with BSS. The specificity of the computerized method was 83.5%, and the diagnostic sensitivity was 89.8%, the accuracy 88.2%, and the correct index 0.733. Comparisons between the computerized integral method and the naked eye integral method showed significant difference in patients of non-BSS or of BSS in various degrees (including mild, moderate and severe) (P < 0.01). The reference value of the naked eye method was below 15. The computerized formula of eye's signs has higher specificity and sensitivity in the diagnosis of BSS, while the naked eye integral method is proved to be useful.
Fishbein, Anna B; Lee, Todd A; Cai, Miao; Oh, Sam S; Eng, Celeste; Hu, Donglei; Huntsman, Scott; Farber, Harold J; Serebrisky, Denise; Silverberg, Jonathan; Williams, L Keoki; Seibold, Max A; Sen, Saunak; Borrell, Luisa N; Avila, Pedro; Rodriguez-Cintron, William; Rodriguez-Santana, Jose R; Burchard, Esteban G; Kumar, Rajesh
2016-07-01
Pest allergen sensitization is associated with asthma morbidity in urban youth but minimally explored in Latino populations. Specifically, the effect of mouse sensitization on the risk of asthma exacerbation has been unexplored in Latino subgroups. To evaluate whether pest allergen sensitization is a predictor of asthma exacerbations and poor asthma control in urban minority children with asthma. Latino and African American children (8-21 years old) with asthma were recruited from 4 sites across the United States. Logistic regression models evaluated the association of mouse or cockroach sensitization with asthma-related acute care visits or hospitalizations. A total of 1,992 children with asthma in the Genes-environments and Admixture in Latino American (GALA-II) and Study of African-Americans, Asthma, Genes, and Environments (SAGE-II) cohorts were studied. Asthmatic children from New York had the highest rate of pest allergen sensitization (42% mouse, 56% cockroach), with the lowest rate in San Francisco (4% mouse, 8% cockroach). Mouse sensitization, more than cockroach, was associated with increased odds of acute care visits (adjusted odds ratio [aOR], 1.47; 95% CI, 1.07-2.03) or hospitalizations (aOR, 3.07; 95% CI, 1.81-5.18), even after controlling for self-reported race and site of recruitment. In stratified analyses, Mexican youth sensitized to mouse allergen did not have higher odds of asthma exacerbation. Other Latino and Puerto Rican youth sensitized to mouse had higher odds of hospitalization for asthma (aORs, 4.57 [95% CI, 1.86-11.22] and 10.01 [95% CI, 1.77-56.6], respectively) but not emergency department visits. Pest allergen sensitization is associated with a higher odds of asthma exacerbations in urban minority youth. Puerto Rican and Other Latino youth sensitized to mouse were more likely to have asthma-related hospitalizations than Mexican youth. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Perzanowski, Matthew S.; Chew, Ginger L.; Divjan, Adnan; Jung, Kyung Hwa; Ridder, Robert; Tang, Deliang; Diaz, Diurka; Goldstein, Inge F.; Kinney, Patrick L.; Rundle, Andrew G.; Camann, David E.; Perera, Frederica P.; Miller, Rachel L.
2013-01-01
Background Sensitization to cockroach is one of the strongest identified risk factors for greater asthma morbidity in low-income, urban communities; however, the timing of exposures relevant to development of sensitization has not been elucidated fully. Further, exposure to combustion byproducts, including polycyclic aromatic hydrocarbons (PAHs), may augment the development of allergic sensitization. Objective To test the hypotheses that domestic cockroach allergen measured prenatally would predict cockroach sensitization in early childhood, and that this association would be greater for children exposed to higher concentrations of PAHs. Methods Dominican and African-American pregnant women living in NYC were enrolled. In the third trimester, expectant mothers wore personal air samplers for measurement of 8 nonvolatile PAHs and the semi-volatile PAH pyrene, and dust was collected from homes for allergen measurement. Glutathione-s-transferase mu (GSTM1) gene polymorphisms were measured in children. Allergen-specific IgE was measured from the children at ages 2, 3, 5 and 7 years. Results Bla g2 in prenatal kitchen dust predicted cockroach sensitization at age 5–7 years [adjusted relative risk (RR) 1.15; P = 0.001; n = 349]. The association was observed only among children above [RR 1.22; P = 0.001], but not below [RR 1.07; P = 0.24] median sum of 8 nonvolatile PAH levels. The association was most pronounced among children with higher PAH and null in the GSTM1 gene [RR 1.54; P = 0.001]. Conclusions Prenatal exposure to cockroach allergen was associated with a greater risk of developing allergic sensitization. This risk was increased by exposure to nonvolatile PAHs, with children null for the GSTM1 mutation particularly vulnerable. Key messages Domestic exposure to cockroach allergen measured prenatally predicted sensitization to cockroach at age 5–7 years. Cockroach allergen predicted sensitization only among children also exposed to higher levels of airborne non-volatile polycyclic aromatic hydrocarbons, indicating that these combustion byproducts may act as adjuvants in the development of cockroach sensitization in urban environments. These findings suggest that targeting either allergen or combustion sources with primary prevention could be successful in reducing the development of cockroach sensitization. PMID:23391330
Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines.
Santo, Susana; Ayres-de-Campos, Diogo; Costa-Santos, Cristina; Schnettler, William; Ugwumadu, Austin; Da Graça, Luís M
2017-02-01
One of the limitations reported with cardiotocography is the modest interobserver agreement observed in tracing interpretation. This study compared agreement, reliability and accuracy of cardiotocography interpretation using the International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines. A total of 151 tracings were evaluated by 27 clinicians from three centers where International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines were routinely used. Interobserver agreement was evaluated using the proportions of agreement and reliability with the κ statistic. The accuracy of tracings classified as "pathological/category III" was assessed for prediction of newborn acidemia. For all measures, 95% confidence interval were calculated. Cardiotocography classifications were more distributed with International Federation of Gynecology and Obstetrics (9, 52, 39%) and National Institute for Health and Care Excellence (30, 33, 37%) than with American College of Obstetrics and Gynecology (13, 81, 6%). The category with the highest agreement was American College of Obstetrics and Gynecology category II (proportions of agreement = 0.73, 95% confidence interval 0.70-76), and the ones with the lowest agreement were American College of Obstetrics and Gynecology categories I and III. Reliability was significantly higher with International Federation of Gynecology and Obstetrics (κ = 0.37, 95% confidence interval 0.31-0.43), and National Institute for Health and Care Excellence (κ = 0.33, 95% confidence interval 0.28-0.39) than with American College of Obstetrics and Gynecology (κ = 0.15, 95% confidence interval 0.10-0.21); however, all represent only slight/fair reliability. International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence showed a trend towards higher sensitivities in prediction of newborn acidemia (89 and 97%, respectively) than American College of Obstetrics and Gynecology (32%), but the latter achieved a significantly higher specificity (95%). With American College of Obstetrics and Gynecology guidelines there is high agreement in category II, low reliability, low sensitivity and high specificity in prediction of acidemia. With International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence guidelines there is higher reliability, a trend towards higher sensitivity, and lower specificity in prediction of acidemia. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Rodrigues, Isolina Mx; Costa, Tatiane L; Avelar, Juliana B; Amaral, Waldemar N; Castro, Ana M; Avelino, Mariza M
2014-06-24
The different laboratory methods used in the diagnosis of congenital toxoplasmosis have variable sensitivity and specificity. There is no evidence to prove that maternal treatment reduces the risk of fetal infection. The purpose of this study was to assess methods for the confirmation of congenital toxoplasmosis after maternal treatment with spiramycin during pregnancy, and to evaluate the effect of this treatment on clinical manifestations of the disease in newborns (NB). This was a community-based, cross-sectional study of acute toxoplasmosis in newborns at risk of acquiring congenital infection. Participating newborns were born in the Clinical Hospital Maternity Ward of the Federal University of Goiás. Eligible participants were divided into 2 groups: group 1 consisted of 44 newborns born to mothers treated with spiramycin during pregnancy and group 2 consisted of 24 newborns born to mothers not treated with spiramycin during pregnancy because the diagnosis of toxoplasmosis was not performed. The sensitivity and specifity of PCR for T. gondii DNA in peripheral blood and serological testing for specific anti-T. gondii IgM and IgA, and the effects of maternal spiramycin treatment on these parameters, were determined by associating test results with clinical manifestations of disease. The sensitivity of the markers (T. gondii DNA detected by PCR, and the presence of specific anti-T. gondii IgM and IgA) for congenital toxoplasmosis was higher in group 2 than in group 1 (31.6, 68.4, 36.8% and 3.7, 25.9, 11.1% respectively). Even with a low PCR sensitivity, the group 2 results indicate the importance of developing new techniques for the diagnosis of congenital toxoplasmosis in newborns. Within group 1, 70.4% of the infected newborns were asymptomatic and, in group 2, 68.4% showed clinical manifestations of congenital toxoplasmosis. The higher proportion of infants without clinical symptoms in group 1 (70.4%) suggests the maternal treatment with spiramycin delays fetal infection, reducing the clinical sequelae of the disease in newborns. Given the low sensitivity of the tests used, when there is suspicion of congenital transmission several serological and parasitological tests are required in order to confirm or exclude congenital toxoplasmosis in newborns.
2014-01-01
Background The different laboratory methods used in the diagnosis of congenital toxoplasmosis have variable sensitivity and specificity. There is no evidence to prove that maternal treatment reduces the risk of fetal infection. The purpose of this study was to assess methods for the confirmation of congenital toxoplasmosis after maternal treatment with spiramycin during pregnancy, and to evaluate the effect of this treatment on clinical manifestations of the disease in newborns (NB). Methods This was a community-based, cross-sectional study of acute toxoplasmosis in newborns at risk of acquiring congenital infection. Participating newborns were born in the Clinical Hospital Maternity Ward of the Federal University of Goiás. Eligible participants were divided into 2 groups: group 1 consisted of 44 newborns born to mothers treated with spiramycin during pregnancy and group 2 consisted of 24 newborns born to mothers not treated with spiramycin during pregnancy because the diagnosis of toxoplasmosis was not performed. The sensitivity and specifity of PCR for T. gondii DNA in peripheral blood and serological testing for specific anti-T. gondii IgM and IgA, and the effects of maternal spiramycin treatment on these parameters, were determined by associating test results with clinical manifestations of disease. Results The sensitivity of the markers (T. gondii DNA detected by PCR, and the presence of specific anti-T. gondii IgM and IgA) for congenital toxoplasmosis was higher in group 2 than in group 1 (31.6, 68.4, 36.8% and 3.7, 25.9, 11.1% respectively). Even with a low PCR sensitivity, the group 2 results indicate the importance of developing new techniques for the diagnosis of congenital toxoplasmosis in newborns. Within group 1, 70.4% of the infected newborns were asymptomatic and, in group 2, 68.4% showed clinical manifestations of congenital toxoplasmosis. Conclusions The higher proportion of infants without clinical symptoms in group 1 (70.4%) suggests the maternal treatment with spiramycin delays fetal infection, reducing the clinical sequelae of the disease in newborns. Given the low sensitivity of the tests used, when there is suspicion of congenital transmission several serological and parasitological tests are required in order to confirm or exclude congenital toxoplasmosis in newborns. PMID:24961630
SHAO, QING; REN, PENGFEI; LI, YANG; PENG, BO; DAI, LIPING; LEI, NINGJING; YAO, WU; ZHAO, GANG; LI, LINGGEN; ZHANG, JIANYING
2012-01-01
Hepatocellular carcinoma (HCC) is a type of cancer with a very poor prognosis. Although α-fetoprotein (AFP) is the most effective marker available to detect HCC, the sensitivity and specificity are not optimal. Therefore, there is a need for the development of more sensitive and specific methods that can supplement AFP in the early detection of this cancer. In this study, autoantibody responses to glucose-regulated protein 78 (GRP78) were evaluated by enzyme-linked immunosorbent assay (ELISA), western blotting and indirect immunofluorescence assay in sera from patients with HCC, liver cirrhosis (LC) and chronic hepatitis (CH), as well as from normal human individuals. Immunohistochemistry (IHC) with tissue array slides was also preformed to analyze protein expression profiles of GRP78 in HCC and control tissues. The prevalence of autoantibodies against GRP78 was 35.5% (27/76) in HCC, which was significantly higher than that in LC, CH and normal human sera (NHS; P<0.01). The average titer of autoantibodies against GRP78 in HCC sera was higher compared to that in LC, CH and NHS(P<0.01). When both autoantibodies against GRP78 and AFP were used simultaneously as diagnostic markers, sensitivity reached 71.4%. Our data indicate that anti-GRP78 autoantibodies may be potential diagnostic markers for HCC, especially in conjunction with AFP. PMID:22692946
Zhao, Huan; Wang, Yong; Wang, Min-Jie; Zhang, Zhi-Hui; Wang, Hai-Rui; Zhang, Bing; Guo, Hui-Qin
2017-04-28
Thyroglobulin measurement with fine-needle aspiration (Tg-FNA) is a sensitive method for detecting metastatic papillary thyroid carcinoma (PTC). However, the diagnostic threshold is not well established and the influence of the thyroid gland on the cutoff value is also controversial. In this study, patients were classified into two groups according to the presence or absence of thyroid tissue, to determine an appropriate cutoff value for clinical practice. Patients with a history of thyroid nodules or surgery for PTC and with enlarged cervical lymph nodes on an FNA examination were enrolled for Tg-FNA detection. One hundred ninety-six lymph nodes (189 patients) were included: 100 from preoperative patients, 49 from patients treated with partial thyroid ablation, and 47 from patients with total thyroid ablation. In 149 lymph nodes from patient with thyroids, the cutoff value for Tg-FNA was 55.99 ng/mL (sensitivity, 95.1%; specificity, 100%), whereas in 47 lymph nodes from patients without a thyroid, it was 9.71 ng/mL (sensitivity, 96.7%; specificity, 100%). Thus, the cutoff value for Tg-FNA was higher in patients with thyroids than in patients without thyroids. The cutoff value for Tg-FNA is influenced by residual thyroid tissue, and a higher cutoff value is recommended for patients with thyroids than for patients without thyroids.
Bozkurt, M; Yumru, A E; Aral, I
2013-01-01
The aim of this study was to investigate the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPPV) of the serum levels of CA-125, CA15-3, CA19-9, carcinoembryonic antigen (CEA), and alpha-fetoprotein (AFP) in the differentiation of benign and malignant ovarian tumors histopathologically diagnosed in patients and to determine the effects of the different test combinations on diagnostic accuracy. One-hundred sixty-eight patients that had their preoperative CA-125, CA15-3, CA19-9, CEA, AFP levels assessed and that were subsequently surgically treated for adnexal masses, were included in the study. For each tumor markers in these patients with histopathologically-confirmed diagnosis, the sensitivity, specificity, PPV and NPV, and diagnostic accuracy, and odds ratio were calculated. The sensitivity, specificity, PPV, NPV of CA125 with cut-off 35 U/ml, were found to be 78.9%, 86.9%, 63.8%, and 93.3%, respectively. The diagnostic odds ratio of CA-125 with cut-off of 35 U/ml, was found to be 25. With cut-off65 U/ml, the sensitivity, specificity, PPV, NPV values were 65.7%, 95.3%, 80.6%, and 90.5%, respectively. The sensitivity, specificity, PPV, and NPV of CEA were 16%, 93%, 37%, and 83%, respectively. For AFP, the sensitivity, specificity, PPV and NPV were to be 2.6%, 98%, 33.3%, and 77.5%, respectively. For CA 15-3, the sensitivity, specificity, PPV and NPV were found to be 26.3% 96.1%, 66.6%, and 81.6%, respectively. Likelihood ratio tests: positive (LR+) = 6.83 and negative (LR-) = 0.76, with an odds ratio: 8.9. The risk of malignancy for adnexal masses with higher CA15-3 increased by approximately nine times. For CA19-9, the sensitivity, specificity, PPV and NPV value were found to be 18.4%, 93%, 43.7%, and 79.6%, respectively. CA19-9 was not statistically significant in the differentiation of benign and malignant of adnexal masses. Even the combinations of CA125 + CEA + CA19-9 and CA125 + CEA + CA19-9 +AFP and CA125 + CA15-3 made a small contribution (one, two, and four cases, respectively), but was not statistically significant. The levels of CA-125 and CA15-3 were found to be significant in order to distinguish benign and malign; CA 19-9, CEA, and AFP were not found to be significant. The different test combinations did not have contribution for diagnostic accuracy.
Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M
2012-01-01
In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.
Morandi, Alessandro; Han, Jin H; Meagher, David; Vasilevskis, Eduard; Cerejeira, Joaquim; Hasemann, Wolfgang; MacLullich, Alasdair M J; Annoni, Giorgio; Trabucchi, Marco; Bellelli, Giuseppe
2016-09-01
Delirium disproportionately affects patients with dementia and is associated with adverse outcomes. The diagnosis of delirium superimposed on dementia (DSD), however, can be challenging due to several factors, including the absence of caregivers or the severity of preexisting cognitive impairment. Altered level of consciousness has been advocated as a possible useful indicator of delirium in this population. Here we evaluated the performance of the Richmond Agitation and Sedation Scale (RASS) and the modified-RASS (m-RASS), an ultra-brief measure of the level of consciousness, in the diagnosis of DSD. Multicenter prospective observational study. RASS and m-RASS results were analyzed together, labeled RASS/m-RASS. Acute geriatric wards, in-hospital rehabilitation, emergency department. Patients 65 years and older with dementia. Delirium was diagnosed with the Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV) or with the Delirium Rating Scale-Revised (DRS-R-98), or with the 4 A's Test (4AT). Dementia was detected with the Clinical Dementia Rating (CDR) Scale, the Short Form-Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) or via the clinical records. Of the 645 patients included, 376 (58%) had delirium. According to the instrument used to evaluate delirium, the prevalence was 66% with the 4AT, 23% with the DSM, and 100% with the DRS-R-98. Overall a RASS/m-RASS score other than 0 was 70.5% sensitive (95% confidence interval [CI] 65.9%-75.1%) and 84.8% (CI 80.5%-89.1%) specific for DSD. Using a RASS/m-RASS value greater than +1 or less than -1 as a cutoff, the sensitivity was 30.6% (CI 25.9%-35.2%) and the specificity was 95.5% (CI 93.1%-98.0%). The sensitivity and the specificity did not greatly vary according to the method of delirium diagnosis and the dementia ascertainment, although the specificity was slightly higher when the DSM and the IQCODE were used. In older patients admitted to different clinical settings, the RASS and m-RASS analyzed as a single group had moderate sensitivity and very high specificity for the detection of DSD. Level of consciousness is therefore a valuable clinical indicator that should form part of delirium screening strategies, although for higher sensitivity other methods of assessment should be used. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Sharma, Parbodh C.; Singh, Dhananjay; Sehgal, Deepmala; Singh, Gurbachan; Hash, C.T.; Yadav, Rattan S.
2014-01-01
Earlier, we established that a major drought tolerance QTL on linkage group 2 of pearl millet is also associated with reduced salt uptake and enhanced growth under salt stress. Present study was undertaken to re-assess the performance of drought tolerant (PRLT 2/89-33) and drought sensitive (H 77/833-2) parents along with two QTL-NILs (ICMR 01029 and ICMR 01040), under salinity stress specifically imposed during post-flowering growth stages when plants had developed their ion sinks in full. Time course changes in ionic accumulation and their compartmentalization in different plant parts was studied, specifically to monitor and capture changes conferred by the two alleles at this QTL, at small intervals. Amongst different plant parts, higher accumulation of toxic ion Na+ was recorded in roots. Further, the Na+ concentration in roots of the testcross hybrid of the drought-sensitive parent (H 77/833-2) reached its maximum at ECiw 15 dS m−1 within 24 h after salinity imposition, whereas it continued to increase with time in the testcross hybrids of the drought tolerant parent PRLT 2/89-33 as well as those of its QTL-NILs (ICMR 01029 and ICMR 01004) and reached at its maximum at 120 h stage. Comparison of differential distribution of toxic ions in individual leaves revealed that Na+ ions were not uniformly distributed in the leaves of the drought-tolerant parent and drought-tolerant QTL-NILs; but accumulated preferentially in the older leaves, whereas the hybrid of the drought-sensitive parent showed significantly higher Na+ concentration in all main stem leaves irrespective of their age. Dynamics of chlorophyll and proline concentration variation studied under salt stress at late flowering stages revealed a greater reduction, almost twice, in both leaf chlorophyll and proline concentrations in younger leaves in the hybrids of the sensitive parent as compared to the tolerant parent and QTL NILs. Imposition of salinity stress even at flowering stage affected the yield performance in pearl millet, wherein higher yield was recorded in drought tolerant parent and the two QTL-NILs compared to drought sensitive parent. PMID:24895469
Sarquiz-Martínez, Brenda; González-Bonilla, César R; Santacruz-Tinoco, Clara Esperanza; Muñoz-Medina, José E; Pardavé-Alejandre, Héctor D; Barbosa-Cabrera, Elizabeth; Ramírez-González, José Ernesto; Díaz-Quiñonez, José Alberto
2017-01-01
Enterovirus (EV) and herpes simplex virus 1 and 2 (HSV1 and HSV2) are the main etiologic agents of central nervous system infections. Early laboratory confirmation of these infections is performed by viral culture of the cerebrospinal fluid (CSF), or the detection of specific antibodies in serum (e.g., HSV). The sensitivity of viral culture ranges from 65 to 75%, with a recovery time varying from 3 to 10 days. Serological tests are faster and easy to carry out, but they exhibit cross-reactivity between HSV1 and HSV2. Although molecular techniques are more sensitive (sensitivity >95%), they are more expensive and highly susceptible to cross-contamination. A real-time RT-PCR for the detection of EV, HSV1, and HSV2 was compared with end-point nested PCR. We tested 87 CSF samples of patients with a clinical diagnosis of viral meningitis or encephalitis. Fourteen samples were found to be positive by RT-PCR, but only 8 were positive by end-point PCR. The RT-PCR showed a specificity range of 94-100%, the negative predictive value was 100%, and the positive predictive value was 62, 100, and 28% for HSV1, HSV2, and EV, respectively. Real-time RT-PCR detected EV, HSV1, and HSV2 with a higher sensitivity and specificity than end-point nested RT-PCR. © 2017 S. Karger AG, Basel.
Bajaj, Ashish; Bhatia, Vinay; Dutt, Sarjana
2016-01-01
Introduction Tuberculosis remains one of the deadliest communicable diseases. There are number of tests available for the diagnosis of tuberculosis but conventional microscopy has low sensitivity and culture although gold standard, but takes longer time for positivity. On the other side, Nucleic acid amplification techniques due to its rapidity and sensitivity not only help in early diagnosis and management of tuberculosis especially in patients with high clinical suspicion like immunocompromised patients, history of contact with active tuberculosis patient etc., but also curtail the transmission of the disease. Aim To evaluate the sensitivity, specificity, positive predictive value and negative predictive value of Nucleic acid amplification assay (GeneXpert) using respiratory samples in patients with suspected pulmonary tuberculosis and compare with AFB smear microscopy (Ziehl Neelsen stain) and Acid Fast Bacilli (AFB) culture. Materials and Methods We retrospectively reviewed the respiratory samples of suspected pulmonary tuberculosis (including Bronchoalveolar lavage and sputum) of 170 patients from Jan 2015 to Nov 2015 for ZN stain, culture and GeneXpert (Xpert® MTB/Rif assay). The sensitivity, specificity, PPV and NPV of GeneXpert and ZN microscopy were calculated using Liquid culture of Mycobacterium tuberculosis as gold standard. Results A total of 170 patient samples were evaluated in final analysis. Of these, 14 samples were positive by all three methods used in our study. The overall sensitivity, specificity, PPV and NPV of GeneXpert were 86.8%, 93.1%, 78.5% and 96% respectively and for BAL sample, 81.4%, 93.4%, 73.3% and 95.7% respectively. The overall sensitivity and specificity of AFB smear microscopy were 22.2%, % and 78.5% respectively and for BAL sample 22.2% and 100% respectively. For AFB negative samples sensitivity and specificity were 79.1% and 93.1% respectively. Conclusion GeneXpert has a higher sensitivity than AFB smear microscopy in respiratory samples. GeneXpert can be a useful tool for early diagnosis of patients with high clinical suspicion of pulmonary tuberculosis. Positive GeneXpert, but culture negative results should be read cautiously and be well correlated with clinical and treatment history of the patient. The other major advantage of Gene Xpert is that it simultaneously detects Rifampicin resistance and especially beneficial in patient with MDR and HIV associated tuberculosis and should be studied further. PMID:27437212
Chaux, Alcides; Cubilla, Antonio L; Haffner, Michael C; Lecksell, Kristen L; Sharma, Rajni; Burnett, Arthur L; Netto, George J
2014-02-01
Infection by high-risk human papillomavirus (HR-HPV) plays an important role in the pathogenesis of penile cancer in approximately 50% of the patients. The gold standard for human papillomavirus (HPV) detection is the polymerase chain reaction (PCR) assay. However, technical requirements and associated costs preclude the worldwide use of PCR assays on a routine basis. Herein, we evaluated the predictive abilities of tumor morphology, immunohistochemistry for p16(INK4a) expression, and in situ hybridization (ISH) for HR-HPV detection in defining HPV status, as established by PCR. Tissue samples from 48 patients with HPV-positive penile squamous cell carcinoma (SCC) were included in 4 tissue microarrays (TMA). Sensitivities and specificities were as follows: tumor morphology, 70% and 68%; p16(INK4a) immunohistochemistry, 65% and 90%; HR-HPV ISH, 47% and 100%. Regarding combinations of the predictors, the best performance was seen when HR-HPV ISH and p16(INK4a) immunohistochemistry were combined, regardless of the tumor morphology: sensitivity, 88%; specificity, 64%; area under the receiver-operating characteristic (AUC) curve, 0.83. Combinations of tumor morphology with p16(INK4a) immunohistochemistry or with HR-HPV ISH performed similarly well. In penile SCC, both p16(INK4a) immunohistochemistry and ISH for HR-HPV increase the predictive ability of routine morphology in defining HPV status. These tests can be interpreted differentially, depending on the necessity of a higher sensitivity or a higher specificity. For research/screening studies, we recommend combining tumor morphology, p16(INK4a) immunohistochemistry, and HR-HPV ISH. To increase sensitivity, positivity in any of these predictors should be considered as indicative of HPV infection. For routine diagnosis of clinical cases, criteria should be more stringent, and, to achieve the highest specificity in classifying a case as HPV-related, all predictors should be consistently positive. The data generated in the present study could be used in algorithms for defining HPV status in penile carcinomas. Copyright © 2014 Elsevier Inc. All rights reserved.
HbA1c for diagnosis and prognosis of gestational diabetes mellitus.
Kwon, Soon Sung; Kwon, Ja-Young; Park, Yong-Won; Kim, Young-Han; Lim, Jong-Baeck
2015-10-01
HbA1c is a widely used marker in diagnosing type 2 diabetes mellitus (DM), but its clinical utility in diagnosing gestational diabetes mellitus (GDM) is not established. Here, we evaluated the clinical usefulness of HbA1c in diagnosing GDM and predicting the risk of future type 2 DM development among GDM patients. This retrospective, cross-sectional study included 321 subjects who underwent 100-g oral glucose tolerance tests (OGTT) during pregnancy. HbA1c and other variables were analyzed to evaluate their diagnostic performance for GDM. To evaluate the clinical usefulness of HbA1c in predicting future type 2 DM development, we classified GDM subjects who had more than 3 months of follow-up data into two subgroups: those who developed postpartum type 2 DM (PDM) and those who did not. HbA1c was significantly higher in the GDM group than in the normal control group. With the 100-g OGTT as reference, HbA1c showed 91.3% sensitivity and 62% specificity at a cut-off value of 5.05% (32 mmol/mol) for GDM diagnosis. At a cut-off value of 5.25% (34 mmol/mol), sensitivity was 73.6% and specificity was 77.2%. HbA1c levels during pregnancy were higher in those with PDM than in those without PDM (5.91 [41 mmol/mol] vs. 5.44% [36 mmol/mol], p<0.001). The prognostic value of HbA1c for PDM was evaluated by ROC curve analysis, with sensitivity of 78.6% and specificity of 72.5% at a cut-off value of 5.55% (37 mmol/mol). HbA1c showed high sensitivity with relatively low specificity for diagnosis of GDM in pregnant women and was a potential predictor of PDM. HbA1c may be able to be used as a simple and less invasive alternative screening test for OGTT in GDM patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Wang, Xiao-ting; Liu, Da-wei; Zhang, Hong-min; He, Huai-wu; Liu, Ye; Chai, Wen-zhao; Du, Wei
2012-12-01
To investigate the effect of the bedside lung ultrasound in emergency(BLUE)-plus lung ultrasound protocol on lung consolidation and atelectasis of critical patients. All patients who need to receive mechanical ventilation for more than 48 hours in ICU from June 2010 to December 2011 in Peking Union Medical College Hospital were included in the study. BLUE-plus and BLUE lung ultrasound, bedside X-ray, lung CT examination were performed on all patients at the same time. The condition of lung consolidation and atelectasis discovered by BLUE-plus lung ultrasound protocol was recorded and compared with bedside X-ray or lung CT. The difference in assessment of lung consolidation and atelectasis between BLUE-plus lung ultrasound protocol and BLUE protocol was compared. A total of 78 patients were finally enrolled in the study. The lung CT found 70 cases (89.74%) had different degrees of lung consolidation and atelectasis. The sensitivity, specificity and diagnostic accuracy of lung consolidation and atelectasis by the bedside chest X-ray were 31.29%, 75.00% and 38.46%, respectively. BLUE-plus lung ultrasound protocol found 68 cases with lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 95.71%, 87.50% and 94.87%, respectively, which were significantly higher than those of lung CT. BLUE protocol found 48 cases of lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 65.71%, 75.00% and 66.67%, respectively. The position of lung consolidation and atelectasis which hadn't been found by BLUE protocol was mainly proved to be located in the basement of lung by lung CT. The incidence of lung consolidation and atelectasis in critical patients who received mechanical ventilation is high. The BLUE-plus lung ultrasound protocol has a relatively higher sensitivity, specificity and diagnostic accuracy for consolidation and atelectasis, which can find majority of consolidation and atelectasis. As BLUE-plus lung ultrasound is a bedside noninvasive method allowing immediate assessment of most lung consolidation and atelectasis, it will be likely the alternative of the CT and play a key role in assessment of lung consolidation and atelectasis.
Ji, Liying; Qian, Mengyao; Wu, Nana; Wu, Jianmin
2017-01-01
The aim of this study was to analyze the mutation rate of JAK2V617F, MPLW515L/K and CALR genes in adult patients with essential thrombocythemia (ET) and the accuracy of the combined detection by the receiver operating curve. Three hundred and forty-two cases with high-platelets (≥300×109/l) were consecutively selected. The patients were analyzed for routine blood examination, bone marrow biopsy and genetic testing. One hundred and fifty-four cases (45.03%) were diagnosed with ET and 188 cases of secondary thrombocythemia according to the hematopoietic and lymphoid tissue tumor classification standards of 2008. It was found that the mutant type of three genes showed three bands, whereas only one band for wild-type. The JAK2V617F and MPL mutations did not cause a change in the open reading frame and the CALR mutation resulted in its change. The mutation rate of JAK2V617F and CALR in ET group was significantly higher than that in the secondary thrombocythemia group (p<0.05). The positive mutation rate of MPL was only 4.55%. JAK2V617F-positive mutation alone was used to diagnose with ET. The area under the curve (AUC) was 0.721. The sensitivity was 72.4%, the specificity was 79.5% and the cut-off value was 0.25. When CALR-positive mutation alone was used to diagnose ET, the AUC, sensitivity, specificity and cut-off value were 0.664, 68.4, 82.4 and 0.09%, respectively. JAK2V617F combined with CALR mutation were used for diagnosis of ET. The AUC was 0.862, the sensitivity was 85.9%, the specificity was 87.8%, and the cut-off values were 0.21 and 0.07. In conclusion, the positive mutation rate of JAK2V617F and CALR in ET was higher, and the sensitivity, specificity and accuracy of the diagnosis of ET were significantly improved using the detection of JAK2V617F and CALR. PMID:28450924
Ji, Liying; Qian, Mengyao; Wu, Nana; Wu, Jianmin
2017-03-01
The aim of this study was to analyze the mutation rate of JAK2V617F, MPLW515L/K and CALR genes in adult patients with essential thrombocythemia (ET) and the accuracy of the combined detection by the receiver operating curve. Three hundred and forty-two cases with high-platelets (≥300×10 9 /l) were consecutively selected. The patients were analyzed for routine blood examination, bone marrow biopsy and genetic testing. One hundred and fifty-four cases (45.03%) were diagnosed with ET and 188 cases of secondary thrombocythemia according to the hematopoietic and lymphoid tissue tumor classification standards of 2008. It was found that the mutant type of three genes showed three bands, whereas only one band for wild-type. The JAK2V617F and MPL mutations did not cause a change in the open reading frame and the CALR mutation resulted in its change. The mutation rate of JAK2V617F and CALR in ET group was significantly higher than that in the secondary thrombocythemia group (p<0.05). The positive mutation rate of MPL was only 4.55%. JAK2V617F-positive mutation alone was used to diagnose with ET. The area under the curve (AUC) was 0.721. The sensitivity was 72.4%, the specificity was 79.5% and the cut-off value was 0.25. When CALR-positive mutation alone was used to diagnose ET, the AUC, sensitivity, specificity and cut-off value were 0.664, 68.4, 82.4 and 0.09%, respectively. JAK2V617F combined with CALR mutation were used for diagnosis of ET. The AUC was 0.862, the sensitivity was 85.9%, the specificity was 87.8%, and the cut-off values were 0.21 and 0.07. In conclusion, the positive mutation rate of JAK2V617F and CALR in ET was higher, and the sensitivity, specificity and accuracy of the diagnosis of ET were significantly improved using the detection of JAK2V617F and CALR.
Oldehinkel, Albertine J; Bouma, Esther M C
2011-08-01
Adolescence is characterized by major biological, psychological, and social challenges, as well as by an increase in depression rates. This review focuses on the association between stressful experiences and depression in adolescence, and the possible role of the hypothalamus-pituitary-adrenal cortex (HPA-)axis in this link. Adolescent girls have a higher probability to develop depressive symptoms than adolescent boys and preadolescents. Increasing evidence indicates that girls' higher risk of depression is partly brought about by an increased sensitivity for stressful life events, particularly interpersonal stressors, which are highly prevalent in adolescent girls. Genetic risk factors for depression, as well as those for stress sensitivity, are often expressed differently in girls and boys. Also environmental adversity tends to affect girls' stress responses more than those of boys. These gender-specific association patterns have been reported for both sensitivity to stressful life events and HPA-axis responses to social stress. Together, the findings suggest that girls are more malleable than boys in response to internal and external influences. This postulated greater malleability may be adaptive in many circumstances, but also brings along risk, such as an increased probability of depression. Copyright © 2010 Elsevier Ltd. All rights reserved.
Evaluating uncertainty and parameter sensitivity in environmental models can be a difficult task, even for low-order, single-media constructs driven by a unique set of site-specific data. The challenge of examining ever more complex, integrated, higher-order models is a formidab...
Monitor Tone Generates Stress in Computer and VDT Operators: A Preliminary Study.
ERIC Educational Resources Information Center
Dow, Caroline; Covert, Douglas C.
A near-ultrasonic pure tone of 15,570 Herz generated by flyback transformers in computer and video display terminal (VDT) monitors may cause severe non-specific irritation or stress disease in operators. Women hear higher frequency sounds than men and are twice as sensitive to "too loud" noise. Pure tones at high frequencies are more…
40 CFR 86.113-94 - Fuel specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for.... Value Octane, Research, Min D2699 93 Sensitivity, Min 7.5 Lead (organic): g/U.S. gal. (g/liter) D3237 1... accumulation. (ii) The octane rating of the gasoline used shall be no higher than 1.0 Research octane number...
Sato, Yasushi; Sagawa, Tamotsu; Hirakawa, Masahiro; Ohnuma, Hiroyuki; Osuga, Takahiro; Okagawa, Yutaka; Tamura, Fumito; Horiguchi, Hiroto; Takada, Kohichi; Hayashi, Tsuyoshi; Sato, Tsutomu; Miyanishi, Koji; Takimoto, Rishu; Kobune, Masayoshi; Kato, Junji
2014-01-01
Background and study aims: The clinical utility of computed virtual chromoendoscopy with flexible spectral imaging color enhancement (FICE) in capsule endoscopy (CE) remains controversial. To clarify the clinical utility of FICE-enhanced CE in evaluating small bowel lesions, we quantitatively assessed white light (WL), FICE, and blue mode (BM) images and examined the sensitivity of these 3 imaging modes of small-bowel lesions from patients who underwent CE. Methods: The CIELAB color difference (∆E) and visual analogue scales (VAS) were measured in 261 CE images (3 different lesion categories) using WL and FICE set 1, 2, and 3, and BM images, respectively. Three endoscopists reviewed CE videos with WL, 3 FICE mode settings, and BM, and compared the sensitivity and detectability for small intestinal diseases from 50 patients who underwent CE. Results: In the assessment of visibility in the 152 vascular lesion images, the ∆E and VAS of FICE set 1, 2, and BM images were significantly higher than that of WL images. In 88 erosion/ulceration images, the ∆E and VAS of FICE set 1 and 2 images were significantly higher than that of WL images. In 21 tumor images, there were no significant differences in ∆E among these modalities. When analyzed on a per-patient basis, FICE settings 1 and 2 had the highest sensitivity (100 %) and specificity (97.3 – 100 %) for vascular lesions. As for erosive/ulcerative lesions, FICE setting 2 had the highest sensitivity (100 %) and specificity (97.2 %). For tumors or polyps, WL had the highest sensitivity (90.9 %) and specificity (87.1 %). In per-lesion analysis, FICE settings 1 and 2 showed significantly superior detection ability over WL for vascular lesions. In the detection of erosive/ulcerative lesions, FICE setting 2 was significantly superior to WL. In tumor images, there was no significant improvement with any of the settings relative to WL images. Conclusions: FICE is most useful for improving CE image quality and detection in cases of angioectasia and erosion/ulceration of the small intestine. PMID:26135265
Song, Heli; Liu, Qingyun; Xie, Yongshu
2018-02-15
As a promising low-cost solar energy conversion technique, dye-sensitized solar cells have undergone spectacular development since 1991. For practical applications, improvement of power conversion efficiency has always been one of the major research topics. Porphyrins are outstanding sensitizers endowed with strong sunlight harvesting ability in the visible region and multiple reaction sites available for functionalization. However, judicious molecular design in consideration of light-harvest, energy levels, operational dynamics, adsorption geometry and suppression of back reactions is specifically required for achieving excellent photovoltaic performance. This feature article highlights some of the recently developed porphyrin sensitizers, especially focusing on the systematic dye structure optimization approach in combination with coadsorption and cosensitization methods in pursuing higher efficiencies. Herein, we expect to provide more insights into the structure-performance correlation and molecular engineering strategies in a stepwise manner.
Ladapo, T A; Fajolu, I B; Adeniyi, O F; Ekure, E N; Maduako, R O; Jaja, T C; Oduwole, A O
2016-01-01
Current methods of detection of childhood hypertension are cumbersome and contribute to under-diagnosis hence, the need to generate simpler diagnostic tools. The blood pressure to height ratio has recently been proposed as a novel screening tool for prehypertension and hypertension in some populations. We evaluated its applicability in our environment. The weights, heights, and blood pressure measurements of 2364 apparently healthy adolescents were determined. Sex-specific systolic and diastolic blood pressure to height ratios (SBPHR) and (DBPHR) were calculated, and their ability to detect prehypertension and hypertension was determined using receiver operating curves. Discriminatory ability was measured by the area under the curve (AUC) and optimal cutoff points along the curve were determined. P < 0.05 was considered statistically significant. The SBPHR and DBPHR were similar across all age groups and sexes. The AUC of SBPHR and DBPHR for diagnosing prehypertension and hypertension by sex was >0.95 for both diastolic and systolic hypertension in both sexes. It ranged between 0.803 and 0.922 for prehypertension and 0.954-0.978 for hypertension indicating higher accuracy for hypertension. Sensitivity was higher for systolic and diastolic hypertension (90-98%) compared with prehypertension (87-98%). Specificity was lower than sensitivity across all categories of hypertension and prehypertension (0.64-0.88%) though higher for hypertension (0.75-0.88) compared with prehypertension (0.64-0.75). BPHR is a useful screening tool for prehypertension and hypertension in black adolescents. Accuracy increased with higher degrees of hypertension.
Cuevas, Luis Eduardo; Al-Sonboli, Najla; Lawson, Lovett; Yassin, Mohammed Ahmed; Arbide, Isabel; Al-Aghbari, Nasher; Bahadur Sherchand, Jeevan; Al-Absi, Amin; Emenyonu, Emmanuel Nnamdi; Merid, Yared; Okobi, Mosis Ifenyi; Onuoha, Juliana Olubunmi; Aschalew, Melkamsew; Aseffa, Abraham; Harper, Greg; Anderson de Cuevas, Rachel Mary; Theobald, Sally Jane; Nathanson, Carl-Michael; Joly, Jean; Faragher, Brian; Squire, Stephen Bertel; Ramsay, Andrew
2011-01-01
Background The diagnosis of tuberculosis (TB) in resource-limited settings relies on Ziehl-Neelsen (ZN) smear microscopy. LED fluorescence microscopy (LED-FM) has many potential advantages over ZN smear microscopy, but requires evaluation in the field. The aim of this study was to assess the sensitivity/specificity of LED-FM for the diagnosis of pulmonary TB and whether its performance varies with the timing of specimen collection. Methods and Findings Adults with cough ≥2 wk were enrolled consecutively in Ethiopia, Nepal, Nigeria, and Yemen. Sputum specimens were examined by ZN smear microscopy and LED-FM and compared with culture as the reference standard. Specimens were collected using a spot-morning-spot (SMS) or spot-spot-morning (SSM) scheme to explore whether the collection of the first two smears at the health care facility (i.e., “on the spot”) the first day of consultation followed by a morning sample the next day (SSM) would identify similar numbers of smear-positive patients as smears collected via the SMS scheme (i.e., one on-the-spot-smear the first day, followed by a morning specimen collected at home and a second on-the-spot sample the second day). In total, 529 (21.6%) culture-positive and 1,826 (74.6%) culture-negative patients were enrolled, of which 1,156 (49%) submitted SSM specimens and 1,199 (51%) submitted SMS specimens. Single LED-FM smears had higher sensitivity but lower specificity than single ZN smears. Using two LED-FM or two ZN smears per patient was 72.8% (385/529, 95% CI 68.8%–76.5%) and 65.8% (348/529, 95% CI 61.6%–69.8%) sensitive (p<0.001) and 90.9% (1,660/1,826, 95% CI 89.5%–92.2%) and 98% (1,790/1,826, 95% CI 97.3%–98.6%) specific (p<0.001). Using three LED-FM or three ZN smears per patient was 77% (408/529, 95% CI 73.3%–80.6%) and 70.5% (373/529, 95% CI 66.4%–74.4%, p<0.001) sensitive and 88.1% (95% CI 86.5%–89.6%) and 96.5% (95% CI 96.8%–98.2%, p<0.001) specific. The sensitivity/specificity of ZN smear microscopy and LED-FM did not vary between SMS and SSM. Conclusions LED-FM had higher sensitivity but, in this study, lower specificity than ZN smear microscopy for diagnosis of pulmonary TB. Performance was independent of the scheme used for collecting specimens. The introduction of LED-FM needs to be accompanied by appropriate training, quality management, and monitoring of performance in the field. Trial Registration Current Controlled Trials ISRCTN53339491 Please see later in the article for the Editors' Summary PMID:21765809
Manevich, Yefim; Reyes, Leticia; Britten, Carolyn D.; Townsend, Danyelle M.
2016-01-01
ME-344 [(3R,4S)-3,4-bis(4-hydroxyphenyl)-8-methyl-3,4-dihydro-2H-chromen-7-ol] is a second-generation derivative natural product isoflavone presently under clinical development. ME-344 effects were compared in lung cancer cell lines that are either intrinsically sensitive or resistant to the drug and in primary immortalized human lung embryonic fibroblasts (IHLEF). Cytotoxicity at low micromolar concentrations occurred only in sensitive cell lines, causing redox stress, decreased mitochondrial ATP production, and subsequent disruption of mitochondrial function. In a dose-dependent manner the drug caused instantaneous and pronounced inhibition of oxygen consumption rates (OCR) in drug-sensitive cells (quantitatively significantly less in drug-resistant cells). This was consistent with targeting of mitochondria by ME-344, with specific effects on the respiratory chain (resistance correlated with higher glycolytic indexes). OCR inhibition did not occur in primary IHLEF. ME-344 increased extracellular acidification rates in drug-resistant cells (significantly less in drug-sensitive cells), implying that ME-344 targets mitochondrial proton pumps. Only in drug-sensitive cells did ME-344 dose-dependently increase the intracellular generation of reactive oxygen species and cause oxidation of total (mainly glutathione) and protein thiols and the concomitant immediate increases in NADPH levels. We conclude that ME-344 causes complex, redox-specific, and mitochondria-targeted effects in lung cancer cells, which differ in extent from normal cells, correlate with drug sensitivity, and provide indications of a beneficial in vitro therapeutic index. PMID:27255112
Berneder, M.; Bublin, M.; Hoffmann-Sommergruber, K.; Hawranek, T.; Lang, R.
2016-01-01
Background Gly m 5 and Gly m 6 are known to induce severe reactions in soy-allergic patients. For birch pollen (BP)-allergic patients, the Bet v 1 homologous allergen Gly m 4 is also a potential trigger of generalized severe reactions upon soy consumption. Therefore, reliable component-resolved diagnosis of soy allergy is needed. Methods IgE reactivity from sera of 20 patients from a BP environment with reported soy allergy was assessed. Skin prick tests (SPT) with BP and soy drink were performed. Specific IgE for BP, soy, Bet v 1 and Gly m 4 was analyzed by ImmunoCAP. In addition, ISAC microarray profiling was performed. Results Nineteen of 20 patients were BP allergic (positive SPT and/or CAP results for BP extract and Bet v 1). Eighteen soy-allergic patients were tested positive with soy drink in SPT. Soy CAP results were negative in the majority of tests (15/20), whereas 19/20 sera had specific IgE to Gly m 4. In the microarray approach, 14/20 sera displayed Gly m 4-specific IgE, the additional 6 sera had IgE levels below 0.3 ISAC standardized units. The BP-negative serum had Gly m 5- and Gly m 6-specific IgE which correlated with positive soy ImmunoCAP. Conclusions Soy sensitization detected by SPT and Gly m 4 ImmunoCAP were in good qualitative agreement with ISAC results. Soy ImmunoCAP was only specific for Gly m 5 and Gly m 6 sensitization. Gly m 4 ImmunoCAP has a higher sensitivity than ImmunoCAP ISAC. In this patient cohort, Gly m 4 sensitization was linked to the development of severe and generalized allergic reactions upon soy consumption. PMID:23548307
Mitchell, Elizabeth O; Stewart, Greg; Bajzik, Olivier; Ferret, Mathieu; Bentsen, Christopher; Shriver, M Kathleen
2013-12-01
A multisite study was conducted to evaluate the performance of the Bio-Rad 4th generation GS HIV Combo Ag/Ab EIA versus Abbott 4th generation ARCHITECT HIV Ag/Ab Combo. The performance of two 3rd generation EIAs, Ortho Diagnostics Anti-HIV 1+2 EIA and Siemens HIV 1/O/2 was also evaluated. Study objective was comparison of analytical HIV-1 p24 antigen detection, sensitivity in HIV-1 seroconversion panels, specificity in blood donors and two HIV false reactive panels. Analytical sensitivity was evaluated with International HIV-1 p24 antigen standards, the AFFSAPS (pg/mL) and WHO 90/636 (IU/mL) standards; sensitivity in acute infection was compared on 55 seroconversion samples, and specificity was evaluated on 1000 negative blood donors and two false reactive panels. GS HIV Combo Ag/Ab demonstrated better analytical HIV antigen sensitivity compared to ARCHITECT HIV Ag/Ab Combo: 0.41 IU/mL versus 1.2 IU/mL (WHO) and 12.7 pg/mL versus 20.1 pg/mL (AFSSAPS); GS HIV Combo Ag/Ab EIA also demonstrated slightly better specificity compared to ARCHITECT HIV Ag/Ab Combo (100% versus 99.7%). The 4th generation HIV Combo tests detected seroconversion 7-11 days earlier than the 3rd generation HIV antibody only EIAs. Both 4th generation immunoassays demonstrated excellent performance in sensitivity, with the reduction of the serological window period (7-11 days earlier detection than the 3rd generation HIV tests). However, GS HIV Combo Ag/Ab demonstrated improved HIV antigen analytical sensitivity and slightly better specificity when compared to ARCHITECT HIV Ag/Ab Combo assay, with higher positive predictive values (PPV) for low prevalence populations. Copyright © 2013 Elsevier B.V. All rights reserved.
Early life IgE responses in children living in the tropics: a prospective analysis.
Zakzuk, Josefina; Acevedo, Nathalie; Cifuentes, Liliana; Bornacelly, Adriana; Sánchez, Jorge; Ahumada, Velky; Ring, Johannes; Ollert, Markus; Caraballo, Luis
2013-12-01
There are few birth cohort studies analyzing IgE sensitization in the tropics. We aimed to describe the evolution of total IgE and specific IgE responses to house-dust mite (HDM) allergens and Ascaris in a birth cohort (Risk Factors for Asthma and Allergy in the Tropics, FRAAT), analyzing their relationships with wheezing. Total and specific IgE were measured by ImmunoCap in mothers and children at four different time points (S1-S4) between 0 and 42 months. Parasite infection was evaluated by stool examination. Maternal total IgE (aOR: 2.43, 95% CI: 1.09-5.43; p = 0.03) and socio-demographic factors were associated with high cord blood (CB) total IgE. High CB total IgE was positively associated with higher Blomia tropicalis and Ascaris-specific IgE values during lifetime, but protected from recurrent wheezing (aOR: 0.26, 95% CI: 0.08-0.88, p = 0.03). Prevalence rates of IgE sensitization were high; at around 3 yr old, they were 33.3, 18.6, and 26.5% for B. tropicalis, Dermatophagoides pteronyssinus, and Ascaris, respectively. Indicators of unhygienic conditions were risk factors for HDM and Ascaris sensitization in children. A weak statistical association between B. tropicalis-specific IgE and ever wheezing was found (aOR: 1.47 95% CI: 1.00-2.28, p = 0.05). In a socioeconomically deprived community from the tropics, sensitization to HDM allergens was very frequent at early life, especially to B. tropicalis. In contrast to expected according to the hygiene hypothesis, unhygienic/poverty conditions were risk factors for allergen sensitization. High CB total IgE levels were a risk factor for allergen sensitization but protected from recurrent wheezing. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter
2016-01-01
A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).
Spering, Cynthia C; Hobson, Valerie; Lucas, John A; Menon, Chloe V; Hall, James R; O'Bryant, Sid E
2012-08-01
To validate and extend the findings of a raised cut score of O'Bryant and colleagues (O'Bryant SE, Humphreys JD, Smith GE, et al. Detecting dementia with the mini-mental state examination in highly educated individuals. Arch Neurol. 2008;65(7):963-967.) for the Mini-Mental State Examination in detecting cognitive dysfunction in a bilingual sample of highly educated ethnically diverse individuals. Archival data were reviewed from participants enrolled in the National Alzheimer's Coordinating Center minimum data set. Data on 7,093 individuals with 16 or more years of education were analyzed, including 2,337 cases with probable and possible Alzheimer's disease, 1,418 mild cognitive impairment patients, and 3,088 nondemented controls. Ethnic composition was characterized as follows: 6,296 Caucasians, 581 African Americans, 4 American Indians or Alaska natives, 2 native Hawaiians or Pacific Islanders, 149 Asians, 43 "Other," and 18 of unknown origin. Diagnostic accuracy estimates (sensitivity, specificity, and likelihood ratio) of Mini-Mental State Examination cut scores in detecting probable and possible Alzheimer's disease were examined. A standard Mini-Mental State Examination cut score of 24 (≤23) yielded a sensitivity of 0.58 and a specificity of 0.98 in detecting probable and possible Alzheimer's disease across ethnicities. A cut score of 27 (≤26) resulted in an improved balance of sensitivity and specificity (0.79 and 0.90, respectively). In the cognitively impaired group (mild cognitive impairment and probable and possible Alzheimer's disease), the standard cut score yielded a sensitivity of 0.38 and a specificity of 1.00 while raising the cut score to 27 resulted in an improved balance of 0.59 and 0.96 of sensitivity and specificity, respectively. These findings cross-validate our previous work and extend them to an ethnically diverse cohort. A higher cut score is needed to maximize diagnostic accuracy of the Mini-Mental State Examination in individuals with college degrees.
Bertran, E A; Berlie, H D; Taylor, A; Divine, G; Jaber, L A
2017-02-01
To examine differences in the performance of HbA 1c for diagnosing diabetes in Arabs compared with Europeans. The PubMed, Embase and Cochrane library databases were searched for records published between 1998 and 2015. Estimates of sensitivity, specificity and log diagnostic odds ratios for an HbA 1c cut-point of 48 mmol/mol (6.5%) were compared between Arabs and Europeans, using a bivariate linear mixed-model approach. For studies reporting multiple cut-points, population-specific summary receiver operating characteristic (SROC) curves were constructed. In addition, sensitivity, specificity and Youden Index were estimated for strata defined by HbA 1c cut-point and population type. Database searches yielded 1912 unique records; 618 full-text articles were reviewed. Fourteen studies met the inclusion criteria; hand-searching yielded three additional eligible studies. Three Arab (N = 2880) and 16 European populations (N = 49 127) were included in the analysis. Summary sensitivity and specificity for a HbA 1c cut-point of 48 mmol/mol (6.5%) in both populations were 42% (33-51%), and 97% (95-98%). There was no difference in area under SROC curves between Arab and European populations (0.844 vs. 0.847; P = 0.867), suggesting no difference in HbA 1c diagnostic accuracy between populations. Multiple cut-point summary estimates stratified by population suggest that Arabs have lower sensitivity and higher specificity at a HbA 1c cut-point of 44 mmol/mol (6.2%) compared with European populations. Estimates also suggest similar test performance at cut-points of 44 mmol/mol (6.2%) and 48 mmol/mol (6.5%) for Arabs. Given the low sensitivity of HbA 1c in the high-risk Arab American population, we recommend a combination of glucose-based and HbA 1c testing to ensure an accurate and timely diagnosis of diabetes. © 2016 Diabetes UK.
Identifying substance misuse in primary care: TAPS Tool compared to the WHO ASSIST.
Schwartz, R P; McNeely, J; Wu, L T; Sharma, G; Wahle, A; Cushing, C; Nordeck, C D; Sharma, A; O'Grady, K E; Gryczynski, J; Mitchell, S G; Ali, R L; Marsden, J; Subramaniam, G A
2017-05-01
There is a need for screening and brief assessment instruments to identify primary care patients with substance use problems. This study's aim was to examine the performance of a two-step screening and brief assessment instrument, the TAPS Tool, compared to the WHO ASSIST. Two thousand adult primary care patients recruited from five primary care clinics in four Eastern US states completed the TAPS Tool followed by the ASSIST. The ability of the TAPS Tool to identify moderate- and high-risk use scores on the ASSIST was examined using sensitivity and specificity analyses. The interviewer and self-administered computer tablet versions of the TAPS Tool generated similar results. The interviewer-administered version (at cut-off of 2), had acceptable sensitivity and specificity for high-risk tobacco (0.90 and 0.77) and alcohol (0.87 and 0.80) use. For illicit drugs, sensitivities were >0.82 and specificities >0.92. The TAPS (at a cut-off of 1) had good sensitivity and specificity for moderate-risk tobacco use (0.83 and 0.97) and alcohol (0.83 and 0.74). Among illicit drugs, sensitivity was acceptable for moderate-risk of marijuana (0.71), while it was low for all other illicit drugs and non-medical use of prescription medications. Specificities were 0.97 or higher for all illicit drugs and prescription medications. The TAPS Tool identified adult primary care patients with high-risk ASSIST scores for all substances as well moderate-risk users of tobacco, alcohol, and marijuana, although it did not perform well in identifying patients with moderate-risk use of other drugs or non-medical use of prescription medications. The advantages of the TAPS Tool over the ASSIST are its more limited number of items and focus solely on substance use in the past 3months. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, A; Devlin, P; Bhagwat, M
Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of themore » clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.« less
Araújo, Inês; Marques, Filipa; André, Sandra; Araújo, Manuel; Marques, Sara; Ferreira, Rita; Moniz, Patrícia; Proença, Margarida; Borrego, Pedro; Fonseca, Cândida
2018-01-17
ApneaLink is a portable device for the screening of sleep apnea, a prevalent and underdiagnosed comorbidity in heart failure patients. A prospective cross-sectional study in patients with chronic heart failure was carried out to assess the sensitivity and specificity of apnea-hypopnea index (AHI) measurements using ApneaLink against the standard polysomnography test. Adult patients with a prior hospitalization in an acute heart failure hospital unit were recruited for the study. All participants were tested for sleep apnea using ApneaLink and polysomnography simultaneously during an overnight stay at a sleep laboratory. Global sleep apnea was evaluated according to the AHI, which was analyzed and compared. Subpopulation comparison based on ejection fraction was not realized due to population size. Thirty-five patients with stable chronic heart failure completed the study (mean age 70.9 ± 10.5 years and body mass index 30.0 ± 4.7 kg/m 2 ). Two patients were excluded due to insufficient study duration. ApneaLink had a sensitivity greater than 80% for all AHI measurements, and a specificity greater than 80% for all AHI measurements, except for AHI ≥ 5 events/h (61.5%). The results showed higher sensitivities and specificities at AHI values of ≥ 10 events/h (sensitivity 81.3% and specificity 84.2%) and ≥ 15 events/h (sensitivity 83.3% and specificity 91.3%). Correlation analysis showed that AHI measurements using ApneaLink and polysomnography had a strong and significant correlation (r = 0.794; P < 0.001). Our results suggest that ApneaLink could be used in clinical practice to identify heart failure patients with high (AHI ≥ 15 events/h) and low (AHI < 5 events/h) probability of having sleep apnea, sparing the need for a diagnostic polysomnography and thus potentially impacting prognosis by providing a more cost-effective and timely diagnosis of this non-cardiac comorbidity.
Montoye, Alexander H K; Pivarnik, James M; Mudd, Lanay M; Biswas, Subir; Pfeiffer, Karin A
2016-01-01
Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-intensity PA [LPA], and moderate- to vigorous-intensity PA [MVPA]) and breaks in SB. Forty young adults (21 female; age 22.0 ± 4.2 years) participated in a 90-minute semi-structured protocol, performing 13 activities (three sedentary, 10 non-sedentary) for 3-10 minutes each. Participants chose activity order, duration, and intensity. Direct observation (DO) was used as a criterion measure of PA intensity category, and transitions from SB to a non-sedentary activity were breaks in SB. Participants wore four accelerometers (right hip, right thigh, and both wrists), and a machine learning model was created for each accelerometer to predict PA intensity category. Sensitivity and specificity for PA intensity category classification were calculated and compared across accelerometers using repeated measures analysis of variance, and the number of breaks in SB was compared using repeated measures analysis of variance. Sensitivity and specificity values for the thigh-worn accelerometer were higher than for wrist- or hip-worn accelerometers, > 99% for all PA intensity categories. Sensitivity and specificity for the hip-worn accelerometer were 87-95% and 93-97%. The left wrist-worn accelerometer had sensitivities and specificities of > 97% for SB and LPA and 91-95% for MVPA, whereas the right wrist-worn accelerometer had sensitivities and specificities of 93-99% for SB and LPA but 67-84% for MVPA. The thigh-worn accelerometer had high accuracy for breaks in SB; all other accelerometers overestimated breaks in SB. Coupled with machine learning modeling, the thigh-worn accelerometer should be considered when objectively assessing PA and SB.
Makhija, Melanie M; Robison, Rachel G; Caruso, Deanna; Cai, Miao; Wang, Xiaobin; Pongracic, Jacqueline A
2016-10-01
Sensitization in adults has not been extensively studied. To investigate patterns of allergen sensitization in parents of food allergic children and to compare self-report of allergic disease with specific IgE (sIgE) measurements. A total of 1,252 mothers and 1,225 fathers of food allergic children answered standardized questionnaires about demographics, home environment, history of atopic diseases, and food allergy. Skin prick testing and sIgE serum tests were performed to 9 foods and 5 aeroallergens. A total of 66.1% of parents were sensitized to either a food or aeroallergen. Mean sIgE levels were low for all foods tested. A total of 14.5% of mothers and 12.7% of fathers reported current food allergy. Only 28.4% had sensitization to their reported allergen. Fathers had significantly higher rates of sensitization to both foods and aeroallergens (P < .01) than mothers. Logistic regression evaluating predictors of self-reported food allergy revealed statistically significant positive associations in fathers with self-reported asthma, environmental allergy, and eczema. For mothers, significant positive associations were found with environmental allergy and having more than 1 food allergic child. This cohort of parents of food allergic children found higher rates of sensitization to foods and aeroallergens compared with the general population. However, food sIgE levels were low and correlated poorly with self-reported food allergy. Sex differences in sensitization to foods and aeroallergens were seen. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Gibson, Lauren E; Anglin, Deidre M; Klugman, Joshua T; Reeves, Lauren E; Fineberg, Anna M; Maxwell, Seth D; Kerns, Connor M; Ellman, Lauren M
2014-06-01
The purpose of this study was to investigate whether stress sensitivity mediates the relationship between traumatic life events and total attenuated positive psychotic symptoms, as well as the relationship between traumatic life events and endorsement of 8 or more attenuated positive psychotic symptoms as distressing (a threshold that has been associated with higher risk for psychosis in clinical groups). Participants (n = 671, aged 17-35, 29% male) were college students who were administered the Prodromal Questionnaire, the Perceived Stress Scale and the Life Events Checklist. Bootstrapping results indicated that stress sensitivity significantly mediated the relationships between traumatic life events and the number of attenuated positive psychotic symptoms endorsed and between traumatic life events and those who endorsed 8 or more distressing attenuated positive psychotic symptoms. Stratified gender analyses indicated the findings were specific to females. Results suggest that stress sensitivity may represent a specific vulnerability factor for risk of attenuated psychotic symptoms in those previously exposed to traumatic life events and that this liability appears stronger in females. Copyright © 2014 Elsevier Ltd. All rights reserved.
Michałowska, Martyna; Walczak, Tomasz; Owen, Adam; Grabski, Jakub Krzysztof; Pyda, Andrzej; Piontek, Tomasz; Kotwicki, Tomasz
2017-01-01
Objective To measure the sensitivity and specificity of differences cut-off values for isokinetic Hcon/Qcon ratio in order to improve the capacity to evaluate (retrospectively) the injury of hamstring muscles in professional soccer screened with knee isokinetic tests. Design Retrospective study. Methods Medical and biomechanical data of professional football players playing for the same team for at least one season between 2010 and 2016 were analysed. Hamstring strain injury cases and the reports generated via isokinetic testing were investigated. Isokinetic concentric(con) hamstring(H) and quadriceps(Q) absolute strength in addition with Hcon/Qcon ratio were examined for the injured versus uninjured limbs among injured players, and for the injured and non-injured players. 2 x 2 contingency table was used for comparing variables: predicted injured or predicted uninjured with actual injured or actual uninjured. Sensitivity, specificity, accuracy, positive and negative predictive values, and positive and negative likelihood ratio were calculated for three different cut-off values (0.47 vs. 0.6 vs. 0.658) to compare the discriminative power of an isokinetic test, whilst examining the key value of Hcon/Qcon ratio which may indicate the highest level of ability to predispose a player to injury. McNemar’s chi2 test with Yates’s correction was used to determine agreement between the tests. PQStat software was used for all statistical analysis, and an alpha level of p <0.05 was used for all statistical comparisons. Results 340 isokinetic test reports on both limbs of 66 professional soccer players were analysed. Eleven players suffered hamstring injuries during the analysed period. None of these players sustained recurrence of hamstring injury. One player sustained hamstring strain injury on both legs, thus the total number of injuries was 12. Application of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic test used as a tool for muscle injury detection. The use of 0.47 of Hcon/Qcon as a discriminate value resulted in significantly lower sensitivity when compared to 0.658 threshold (sensitivity of 16.7% vs. 91.7%, respectively; t = 6.125,p = 0.0133). Calculated values of specificity (when three different cut-off were applied) were also significantly different. Threshold of 0.6 of Hcon/Qcon resulted with significantly lower specificity compared to 0.47 value (specificity of 46.9% vs. 94.5%, respectively; t = 153.0,p<0.0001), and significantly higher specificity when compared to 0.658 (specificity of 46.9% vs. 24.1%, respectively; t = 229.0, p<0.0001). Conclusion The use of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic testing. The interpretation of usefulness of isokinetic test as a screening tool in a group of male professional football players to predict hamstring injury occurrence within the next 12 months might be therefore significantly biased due to the different threshold values of Hcon/Qcon. Using one “normative” value as a cut-off (e.g. 0.47 or 0.60, or 0.658) to quantify soccer players (or not) to the group with a higher risk of knee injury might result in biased outcomes due to the natural strength asymmetry that is observed within the group of soccer players. PMID:29216241
Grygorowicz, Monika; Michałowska, Martyna; Walczak, Tomasz; Owen, Adam; Grabski, Jakub Krzysztof; Pyda, Andrzej; Piontek, Tomasz; Kotwicki, Tomasz
2017-01-01
To measure the sensitivity and specificity of differences cut-off values for isokinetic Hcon/Qcon ratio in order to improve the capacity to evaluate (retrospectively) the injury of hamstring muscles in professional soccer screened with knee isokinetic tests. Retrospective study. Medical and biomechanical data of professional football players playing for the same team for at least one season between 2010 and 2016 were analysed. Hamstring strain injury cases and the reports generated via isokinetic testing were investigated. Isokinetic concentric(con) hamstring(H) and quadriceps(Q) absolute strength in addition with Hcon/Qcon ratio were examined for the injured versus uninjured limbs among injured players, and for the injured and non-injured players. 2 x 2 contingency table was used for comparing variables: predicted injured or predicted uninjured with actual injured or actual uninjured. Sensitivity, specificity, accuracy, positive and negative predictive values, and positive and negative likelihood ratio were calculated for three different cut-off values (0.47 vs. 0.6 vs. 0.658) to compare the discriminative power of an isokinetic test, whilst examining the key value of Hcon/Qcon ratio which may indicate the highest level of ability to predispose a player to injury. McNemar's chi2 test with Yates's correction was used to determine agreement between the tests. PQStat software was used for all statistical analysis, and an alpha level of p <0.05 was used for all statistical comparisons. 340 isokinetic test reports on both limbs of 66 professional soccer players were analysed. Eleven players suffered hamstring injuries during the analysed period. None of these players sustained recurrence of hamstring injury. One player sustained hamstring strain injury on both legs, thus the total number of injuries was 12. Application of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic test used as a tool for muscle injury detection. The use of 0.47 of Hcon/Qcon as a discriminate value resulted in significantly lower sensitivity when compared to 0.658 threshold (sensitivity of 16.7% vs. 91.7%, respectively; t = 6.125,p = 0.0133). Calculated values of specificity (when three different cut-off were applied) were also significantly different. Threshold of 0.6 of Hcon/Qcon resulted with significantly lower specificity compared to 0.47 value (specificity of 46.9% vs. 94.5%, respectively; t = 153.0,p<0.0001), and significantly higher specificity when compared to 0.658 (specificity of 46.9% vs. 24.1%, respectively; t = 229.0, p<0.0001). The use of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic testing. The interpretation of usefulness of isokinetic test as a screening tool in a group of male professional football players to predict hamstring injury occurrence within the next 12 months might be therefore significantly biased due to the different threshold values of Hcon/Qcon. Using one "normative" value as a cut-off (e.g. 0.47 or 0.60, or 0.658) to quantify soccer players (or not) to the group with a higher risk of knee injury might result in biased outcomes due to the natural strength asymmetry that is observed within the group of soccer players.
Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe
2017-01-01
Late blight, caused by the oomycete Phytophthora infestans, is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10-4 ng μL-1), being 10 times more sensitive than nested PCR (1.28 × 10-3 ng μL-1), 100 times more sensitive than real-time PCR (1.28 × 10-2 ng μL-1) and 103 times more sensitive than the conventional PCR assay (1.28 × 10-1 ng μL-1). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics. PMID:29051751
Tegegne, Banchamlak; Getie, Sisay; Lemma, Wossenseged; Mohon, Abu Naser; Pillai, Dylan R
2017-01-19
Malaria is a major public health problem and an important cause of maternal and infant morbidity in sub-Saharan Africa, including Ethiopia. Early and accurate diagnosis of malaria with effective treatment is the best strategy for prevention and control of complications during pregnancy and infant morbidity and mortality. However, laboratory diagnosis has relied on the identification of malaria parasites and parasite antigens in peripheral blood using Giemsa-stained microscopy or rapid diagnostic tests (RDTs) which lack analytical and clinical sensitivity. The aim of this study was to evaluate the performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia. A cross sectional study was conducted from January to April 2016. Pregnant women (n = 87) suspected of having malaria at six health centres were enrolled. A venous blood sample was collected from each study subject, and analysed for Plasmodium parasites by microscopy, RDT, and LAMP. Diagnostic accuracy outcome measures (sensitivity, specificity, predictive values, and Kappa scores) of microscopy, RDT and LAMP were compared to nested polymerase chain reaction (nPCR) as the gold standard. Specimen processing and reporting times were documented. Using nPCR as the gold standard technique, the sensitivity of microscopy and RDT was 90 and 70%, and the specificity was 98.7 and 97.4%, respectively. LAMP assay was 100% sensitive and 93.5% specific compared to nPCR. This study showed higher sensitivity of LAMP compared to microscopy and RDT for the detection of malaria in pregnancy. Increased sensitivity and ease of use with LAMP in point-of-care testing for malaria in pregnancy was noted. LAMP warrants further evaluation in intermittent screening and treatment programmes in pregnancy.
Disler, D G; McCauley, T R; Kelman, C G; Fuchs, M D; Ratner, L M; Wirth, C R; Hospodar, P P
1996-07-01
The sensitivity of fat-suppressed three-dimensional spoiled gradient-echo (SPGR) images was compared with that of standard MR images for detecting hyaline cartilage defects of the knee, using arthroscopy as the standard of reference. We assessed 114 consecutive patients for hyaline cartilage defects of the knee with both standard MR imaging sequences and a sagittal fat-suppressed three-dimensional SPGR sequence. Of these patients, 48 with meniscal or ligament injury, or persistent symptoms, underwent subsequent arthroscopy. The standard MR images and SPGR images of these 48 patients were then retrospectively analyzed for articular defects in a blinded fashion by two independent observers. Sensitivity, specificity, and intraobserver and interobserver agreement were determined for the different imaging techniques. One fourth of the patients who went on to arthroscopy were shown to have isolated hyaline cartilage lesions that were clinically confused with meniscal tears and that were missed on the standard MR images. When looking at all surfaces combined for each reader, the SPGR imaging sequence had a significantly higher sensitivity than the standard MR imaging sequences for detecting hyaline cartilage defects (75-85% versus 29-38%, p < .001 for each comparison). When looking at individual surfaces for each reader, significant differences in sensitivity were shown for each surface except the trochlear and lateral tibial surfaces. We found no difference in specificity (97% versus 97%, p > .99). We also found that combined evaluation of standard MR and SPGR images gave no added diagnostic advantage (sensitivity, 86%; specificity, 97%; p > .42). Except for the lateral tibial surface, the study achieved excellent reproducibility among readings and between readers. Fat-suppressed three-dimensional SPGR imaging is more sensitive than standard MR imaging for the detection of hyaline cartilage defects of the knee.
Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe
2017-01-01
Late blight, caused by the oomycete Phytophthora infestans , is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10 -4 ng μL -1 ), being 10 times more sensitive than nested PCR (1.28 × 10 -3 ng μL -1 ), 100 times more sensitive than real-time PCR (1.28 × 10 -2 ng μL -1 ) and 10 3 times more sensitive than the conventional PCR assay (1.28 × 10 -1 ng μL -1 ). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics.
Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa
2017-11-01
Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.
NASA Technical Reports Server (NTRS)
Li, Tiantian; Ban, Jie; Horton, Radley M.; Bader, Daniel A.; Huang, Ganlin; Sun, Qinghua; Kinney, Patrick L.
2015-01-01
Because heat-related health effects tend to become more serious at higher temperatures, there is an urgent need to determine the mortality projection of specific heat-sensitive diseases to provide more detailed information regarding the variation of the sensitivity of such diseases. In this study, the specific mortality of cardiovascular and respiratory disease in Beijing was initially projected under five different global-scale General Circulation Models (GCMs) and two Representative Concentration Pathways scenarios (RCPs) in the 2020s, 2050s, and 2080s compared to the 1980s. Multi-model ensembles indicated cardiovascular mortality could increase by an average percentage of 18.4 percent, 47.8 percent, and 69.0 percent in the 2020s, 2050s, and 2080s under RCP 4.5, respectively, and by 16.6 percent, 73.8 percent and 134 percent in different decades respectively, under RCP 8.5 compared to the baseline range. The same increasing pattern was also observed in respiratory mortality. The heat-related deaths under the RCP 8.5 scenario were found to reach a higher number and to increase more rapidly during the 21st century compared to the RCP4.5 scenario, especially in the 2050s and the 2080s. The projection results show potential trends in cause-specific mortality in the context of climate change, and provide support for public health interventions tailored to specific climate-related future health risks.
Silva, Juliana O; Fernandes, Renata S; Lopes, Sávia C A; Cardoso, Valbert N; Leite, Elaine A; Cassali, Geovanni D; Marzola, Maria Cristina; Rubello, Domenico; Oliveira, Monica C; de Barros, Andre Luis Branco
2016-12-01
Therapeutic agents used in chemotherapy have low specificity leading to undesired severe side effects. Hence, the development of drug delivery systems that improve drug specificity, such as liposome moieties, is an alternative to overcome chemotherapy limitations and increase antitumor efficacy. In this study, the biodistribution profile evaluation of pH-sensitive long-circulating liposomes (SpHL) containing [ 99m Tc]DOX in 4T1 tumor-bearing BALB/c mice is described. [ 99m Tc]DOX was radiolabeled by direct method. Liposomes were prepared and characterized. [ 99m Tc]DOX was encapsulated into liposomes by freezing and thawing. Circulation time for SpHL-[ 99m Tc]DOX was determined by measuring the blood activity from healthy animals. Biodistribution studies were carried out in tumor-bearing mice at 1, 4, and 24 h after injection. Blood levels of the SpHL-[ 99m Tc]DOX declined in a biphasic manner, with an α half-life of 14.1 min and β half-life of 129.0 min. High uptake was achieved in the liver and spleen, due to the macrophages captured. Moreover, tumor uptake was higher than control tissue, resulting in high tumor-to-muscle ratios, indicating higher specificity for the tumor area. [ 99m Tc]DOX was successfully encapsulated in liposomes. Biodistribution indicated high tumor-to-muscle ratios in breast tumor-bearing BALB/c mice. In summary, these results showed the higher accumulation of SpHL-[ 99m Tc]DOX in the tumor area, suggesting selective delivery of doxorubicin into tumor.
Hovland, S; Arbyn, M; Lie, A K; Ryd, W; Borge, B; Berle, E J; Skomedal, H; Kadima, T M; Kyembwa, L; Billay, E M; Mukwege, D; Chirimwami, R B; Mvula, T M; Snijders, P J; Meijer, C J L M; Karlsen, F
2010-01-01
Background: Given the high burden of cervical cancer in low-income settings, there is a need for a convenient and affordable method for detecting and treating pre-cancerous lesions. Methods: Samples for comparing the accuracy of cytology, virology and histology were collected. Identification of HPV E6/E7 mRNA was performed using PreTect HPV-Proofer. HPV DNA detection was performed by GP5+/6+ PCR, followed by reverse line blot (RLB) for typing. Results: A total of 343 women, aged 25–60 years, attending gynaecological polyclinics in DR Congo were included for sample enrolment. The test positivity rate was conventional and liquid-based cytology (LBC) at cutoff ASCUS+ of 6.9 and 6.6%, respectively; PreTect HPV-Proofer of 7.3% and consensus DNA PCR for 14 HR types of 18.5%. Sixteen cases of CIN2+ lesions were identified. Of these, conventional cytology identified 66.7% with a specificity of 96.2%, LBC identified 73.3% with a specificity of 96.9%, all at cutoff ASCUS+. HR-HPV DNA detected all CIN2+ cases with a specificity of 85.9%, whereas PreTect HPV-Proofer gave a sensitivity of 81.3% and a specificity of 96.6%. Conclusion: Both HPV detection assays showed a higher sensitivity for CIN2+ than did cytological methods. Detecting E6/E7 mRNA from only a subset of HR HPVs, as is the case with PreTect HPV-Proofer, resulted in a similar specificity to cytology and a significantly higher specificity than consensus HR HPV DNA (P<0.0001). PMID:20197765
Weekes, Anthony J; Thacker, Gregory; Troha, Daniel; Johnson, Angela K; Chanler-Berat, Jordan; Norton, H James; Runyon, Michael
2016-09-01
We determine the diagnostic accuracy of goal-directed echocardiography, cardiac biomarkers, and computed tomography (CT) in early identification of severe right ventricular dysfunction in normotensive emergency department patients with pulmonary embolism compared with comprehensive echocardiography. This was a prospective observational study of consecutive normotensive patients with confirmed pulmonary embolism. Investigators, blinded to clot burden and biomarkers, performed qualitative goal-directed echocardiography for right ventricular dysfunction: right ventricular enlargement (diameter greater than or equal to that of the left ventricle), severe right ventricular systolic dysfunction, and septal bowing. Brain natriuretic peptide and troponin cutoffs of greater than or equal to 90 pg/mL and greater than or equal to 0.07 ng/mL and CT right ventricular:left ventricular diameter ratio greater than or equal to 1.0 were also compared with comprehensive echocardiography. One hundred sixteen normotensive pulmonary embolism patients (111 confirmed by CT, 5 by ventilation-perfusion scan) were enrolled. Twenty-six of 116 patients (22%) had right ventricular dysfunction on comprehensive echocardiography. Goal-directed echocardiography had a sensitivity of 100% (95% confidence interval [CI] 87% to 100%), specificity of 99% (95% CI 94% to 100%), positive likelihood ratio (+LR) of 90.0 (95% CI 16.3 to 499.8), and negative likelihood ratio (-LR) of 0 (95% CI 0 to 0.13). Brain natriuretic peptide had a sensitivity of 88% (95% CI 70% to 98%), specificity of 68% (95% CI 57% to 78%), +LR of 2.8 (95% CI 2.0 to 3.9), and -LR of 0.17 (95% CI 0.06 to 0.43). Troponin had a sensitivity of 62% (95% CI 41% to 80%), specificity of 93% (95% CI 86% to 98%), +LR of 9.2 (95% CI 4.1 to 20.9), and -LR of 0.41 (95% CI 0.24 to 0.62). CT had a sensitivity of 91% (95% CI 72% to 99%), specificity of 79% (95% CI 69% to 87%), +LR of 4.3 (95% CI 2.8 to 6.7), and -LR of 0.11 (95% CI 0.03 to 0.34). Goal-directed echocardiography was highly accurate for early severe right ventricular dysfunction identification and pulmonary embolism risk-stratification. Brain natriuretic peptide was sensitive but less specific, whereas troponin had lower sensitivity but higher specificity. CT had good sensitivity and moderate specificity. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Svraka-Latifovic, S; Bouter, S; Naus, H; Bakker, L J; Timmerman, C P; Dorigo-Zetsma, J W
2014-11-01
Detection of intestinal protozoa by PCR methods has been described as being sensitive and specific, and as improving the diagnostic yield. Here we present the outcome of the transition from microscopy to molecular screening for detection of a select group of intestinal protozoa in faeces in our laboratory. Introduction of molecular screening for intestinal protozoa resulted in higher sensitivity, reduced hands-on-time, reduced time-to-results, leading to improved diagnostic efficiency. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.
MRI in multiple sclerosis: current status and future prospects
Bakshi, Rohit; Thompson, Alan J; Rocca, Maria A; Pelletier, Daniel; Dousset, Vincent; Barkhof, Frederik; Inglese, Matilde; Guttmann, Charles R G; Horsfield, Mark A; Filippi, Massimo
2008-01-01
Many promising MRI approaches for research or clinical management of multiple sclerosis (MS) have recently emerged, or are under development or refinement. Advanced MRI methods need to be assessed to determine whether they allow earlier diagnosis or better identification of phenotypes. Improved post-processing should allow more efficient and complete extraction of information from images. Magnetic resonance spectroscopy should improve in sensitivity and specificity with higher field strengths and should enable the detection of a wider array of metabolites. Diffusion imaging is moving closer to the goal of defining structural connectivity and, thereby, determining the functional significance of lesions at specific locations. Cell-specific imaging now seems feasible with new magnetic resonance contrast agents. The imaging of myelin water fraction brings the hope of providing a specific measure of myelin content. Ultra-high-field MRI increases sensitivity, but also presents new technical challenges. Here, we review these recent developments in MRI for MS, and also look forward to refinements in spinal-cord imaging, optic-nerve imaging, perfusion MRI, and functional MRI. Advances in MRI should improve our ability to diagnose, monitor, and understand the pathophysiology of MS. PMID:18565455
BERRY, DANIEL; BLAIR, CLANCY; WILLOUGHBY, MICHAEL; GRANGER, DOUGLAS A.; MILLS-KOONCE, W. ROGER
2018-01-01
Theory suggests that early experiences may calibrate the “threshold activity” of the hypothalamus–pituitary–adrenal axis in childhood. Particularly challenging or particularly supportive environments are posited to manifest in heightened physiological sensitivity to context. Using longitudinal data from the Family Life Project (N = 1,292), we tested whether links between maternal sensitivity and hypothalamus–pituitary–adrenal axis activity aligned with these predictions. Specifically, we tested whether the magnitude of the within-person relation between maternal sensitivity and children’s cortisol levels, a proxy for physiological sensitivity to context, was especially pronounced for children who typically experienced particularly low or high levels of maternal sensitivity over time. Our results were consistent with these hypotheses. Between children, lower levels of mean maternal sensitivity (7–24 months) were associated with higher mean cortisol levels across this period (measured as a basal sample collected at each visit). However, the magnitude and direction of the within-person relation was contingent on children’s average levels of maternal sensitivity over time. Increases in maternal sensitivity were associated with contemporaneous cortisol decreases for children with typically low-sensitive mothers, whereas sensitivity increases were associated with cortisol increases for children with typically high-sensitive mothers. No within-child effects were evident at moderate levels of maternal sensitivity. PMID:27065311
Lameness scoring system for dairy cows using force plates and artificial intelligence.
Ghotoorlar, S Mokaram; Ghamsari, S Mehdi; Nowrouzian, I; Ghotoorlar, S Mokaram; Ghidary, S Shiry
2012-02-04
Lameness scoring is a routine procedure in dairy industry to screen the herds for new cases of lameness. Subjective lameness scoring, which is the most popular lameness detection and screening method in dairy herds, has several limitations. They include low intra-observer and inter-observer agreement and the discrete nature of the scores which limits its usage in monitoring the lameness. The aim of this study is to develop an automated lameness scoring system comparable with conventional subjective lameness scoring by means of artificial neural networks. The system is composed of four balanced force plates installed in a hoof-trimming box. A group of 105 dairy cows was used for the study. Twenty-three features extracted from ground reaction force (GRF) data were used in a computer training process which was performed on 60 per cent of the data. The remaining 40 per cent of the data were used to test the trained system. Repeatability of the lameness scoring system was determined by GRF samples from 25 cows, captured at two different times from the same animals. The mean sd was 0.31 and the mean coefficient of variation was 14.55 per cent, which represents a high repeatability in comparison with subjective vision-based scoring methods. Although the highest sensitivity and specificity values were seen in locomotion score groups 1 and 4, the automatic lameness system was both sensitive and specific in all groups. The sensitivity and specificity were higher than 72 per cent in locomotion score groups 1 to 4, and it was 100 per cent specific and 50 per cent sensitive for group 5.
Hu, Xiangdong; Liu, Yujiang; Qian, Linxue
2017-10-01
Real-time elastography (RTE) and shear wave elastography (SWE) are noninvasive and easily available imaging techniques that measure the tissue strain, and it has been reported that the sensitivity and the specificity of elastography were better in differentiating between benign and malignant thyroid nodules than conventional technologies. Relevant articles were searched in multiple databases; the comparison of elasticity index (EI) was conducted with the Review Manager 5.0. Forest plots of the sensitivity and specificity and SROC curve of RTE and SWE were performed with STATA 10.0 software. In addition, sensitivity analysis and bias analysis of the studies were conducted to examine the quality of articles; and to estimate possible publication bias, funnel plot was used and the Egger test was conducted. Finally 22 articles which eventually satisfied the inclusion criteria were included in this study. After eliminating the inefficient, benign and malignant nodules were 2106 and 613, respectively. The meta-analysis suggested that the difference of EI between benign and malignant nodules was statistically significant (SMD = 2.11, 95% CI [1.67, 2.55], P < .00001). The overall sensitivities of RTE and SWE were roughly comparable, whereas the difference of specificities between these 2 methods was statistically significant. In addition, statistically significant difference of AUC between RTE and SWE was observed between RTE and SWE (P < .01). The specificity of RTE was statistically higher than that of SWE; which suggests that compared with SWE, RTE may be more accurate on differentiating benign and malignant thyroid nodules.
Hu, Xiangdong; Liu, Yujiang; Qian, Linxue
2017-01-01
Abstract Background: Real-time elastography (RTE) and shear wave elastography (SWE) are noninvasive and easily available imaging techniques that measure the tissue strain, and it has been reported that the sensitivity and the specificity of elastography were better in differentiating between benign and malignant thyroid nodules than conventional technologies. Methods: Relevant articles were searched in multiple databases; the comparison of elasticity index (EI) was conducted with the Review Manager 5.0. Forest plots of the sensitivity and specificity and SROC curve of RTE and SWE were performed with STATA 10.0 software. In addition, sensitivity analysis and bias analysis of the studies were conducted to examine the quality of articles; and to estimate possible publication bias, funnel plot was used and the Egger test was conducted. Results: Finally 22 articles which eventually satisfied the inclusion criteria were included in this study. After eliminating the inefficient, benign and malignant nodules were 2106 and 613, respectively. The meta-analysis suggested that the difference of EI between benign and malignant nodules was statistically significant (SMD = 2.11, 95% CI [1.67, 2.55], P < .00001). The overall sensitivities of RTE and SWE were roughly comparable, whereas the difference of specificities between these 2 methods was statistically significant. In addition, statistically significant difference of AUC between RTE and SWE was observed between RTE and SWE (P < .01). Conclusion: The specificity of RTE was statistically higher than that of SWE; which suggests that compared with SWE, RTE may be more accurate on differentiating benign and malignant thyroid nodules. PMID:29068996
Tang, Lin-Quan; Zhang, Hua; Li, Yan; Liu, Wan-Li; Zhong, Qian; Zeng, Mu-Sheng; Huang, Xiao-Ming
2016-01-01
To determine whether measuring antibodies against Epstein-Barr virus (EBV) glycoprotein gH/gL in serum could improve diagnostic accuracy in nasopharyngeal carcinoma (NPC) cases, gH/gL expressed in a recombinant baculovirus system was used in an enzyme-linked immunosorbent assay (ELISA) to detect antibodies in two independent cohorts. Binary logistic regression analyses were performed using results from a training cohort (n = 406) to establish diagnostic mathematical models, which were validated in a second independent cohort (n = 279). Levels of serum gH/gL antibodies were higher in NPC patients than in healthy controls (p < 0.001). In the training cohort, the IgA-gH/gL ELISA had a sensitivity of 83.7%, specificity of 82.3% and area under the curve (AUC) of 0.893 (95% CI, 0.862-0.924) for NPC diagnosis. Furthermore, gH/gL maintained diagnostic capacity in IgA-VCA negative NPC patients (sensitivity = 78.1%, specificity = 82.3%, AUC = 0.879 [95% CI, 0.820 - 0.937]). Combining gH/gL and viral capsid antigen (VCA) detection improved diagnostic capacity as compared to individual tests alone in both the training cohort (sensitivity = 88.5%, specificity = 97%, AUC = 0.98 [95% CI, 0.97 - 0.991]), and validation cohort (sensitivity = 91.2%, specificity = 96.5%, AUC = 0.97 [95% CI, 0.951-0.988]). These findings suggest that EBV gH/gL detection complements VCA detection in the diagnosis of NPC and aids in the identification of patients with VCA-negative NPC. PMID:27093005
The Brief Early Childhood Screening Assessment: Preliminary Validity in Pediatric Primary Care.
Fallucco, Elise M; Wysocki, Tim; James, Lauren; Kozikowski, Chelsea; Williams, Andre; Gleason, Mary M
Brief, well-validated instruments are needed to facilitate screening for early childhood behavioral and emotional problems (BEPs). The objectives of this study were to empirically reduce the length of the Early Childhood Screening Assessment (ECSA) and to assess the validity and reliability of this shorter tool. Using caregiver ECSA responses for 2467 children aged 36 to 60 months seen in primary care, individual ECSA items were ranked on a scale ranging from "absolutely retain" to "absolutely delete." Items were deleted sequentially beginning with "absolutely delete" and going up the item prioritization list, resulting in 35 shorter versions of the ECSA. A separate primary care sample (n = 69) of mothers of children aged 18 to 60 months was used to determine the sensitivity and specificity of each shorter ECSA version using psychiatric diagnosis on the Diagnostic Infant and Preschool Assessment as the gold standard. The version with the optimal balance of sensitivity, specificity, and length was selected as the Brief ECSA. Associations between Brief ECSA scores and other pertinent measures were evaluated to estimate reliability and validity. A 22-item measure reflected the best combination of brevity, sensitivity and specificity. A cutoff score of 9 or higher on the 22-item Brief ECSA demonstrated acceptable sensitivity (89%) and specificity (85%) for predicting a psychiatric diagnosis. Brief ECSA scores correlated significantly and in expected directions with scores on pertinent measures and with demographic variables. The results indicate that the Brief ECSA has sound psychometric properties for identifying young children with BEPs in primary care.
Identifying Talent in Youth Sport: A Novel Methodology Using Higher-Dimensional Analysis.
Till, Kevin; Jones, Ben L; Cobley, Stephen; Morley, David; O'Hara, John; Chapman, Chris; Cooke, Carlton; Beggs, Clive B
2016-01-01
Prediction of adult performance from early age talent identification in sport remains difficult. Talent identification research has generally been performed using univariate analysis, which ignores multivariate relationships. To address this issue, this study used a novel higher-dimensional model to orthogonalize multivariate anthropometric and fitness data from junior rugby league players, with the aim of differentiating future career attainment. Anthropometric and fitness data from 257 Under-15 rugby league players was collected. Players were grouped retrospectively according to their future career attainment (i.e., amateur, academy, professional). Players were blindly and randomly divided into an exploratory (n = 165) and validation dataset (n = 92). The exploratory dataset was used to develop and optimize a novel higher-dimensional model, which combined singular value decomposition (SVD) with receiver operating characteristic analysis. Once optimized, the model was tested using the validation dataset. SVD analysis revealed 60 m sprint and agility 505 performance were the most influential characteristics in distinguishing future professional players from amateur and academy players. The exploratory dataset model was able to distinguish between future amateur and professional players with a high degree of accuracy (sensitivity = 85.7%, specificity = 71.1%; p<0.001), although it could not distinguish between future professional and academy players. The validation dataset model was able to distinguish future professionals from the rest with reasonable accuracy (sensitivity = 83.3%, specificity = 63.8%; p = 0.003). Through the use of SVD analysis it was possible to objectively identify criteria to distinguish future career attainment with a sensitivity over 80% using anthropometric and fitness data alone. As such, this suggests that SVD analysis may be a useful analysis tool for research and practice within talent identification.
White, Brad J; Goehl, Dan R; Amrine, David E; Booker, Calvin; Wildman, Brian; Perrett, Tye
2016-04-01
Accurate diagnosis of bovine respiratory disease (BRD) in beef cattle is a critical facet of therapeutic programs through promotion of prompt treatment of diseased calves in concert with judicious use of antimicrobials. Despite the known inaccuracies, visual observation (VO) of clinical signs is the conventional diagnostic modality for BRD diagnosis. Objective methods of remotely monitoring cattle wellness could improve diagnostic accuracy; however, little information exists describing the accuracy of this method compared to traditional techniques. The objective of this research is to employ Bayesian methodology to elicit diagnostic characteristics of conventional VO compared to remote early disease identification (REDI) to diagnose BRD. Data from previous literature on the accuracy of VO were combined with trial data consisting of direct comparison between VO and REDI for BRD in two populations. No true gold standard diagnostic test exists for BRD; therefore, estimates of diagnostic characteristics of each test were generated using Bayesian latent class analysis. Results indicate a 90.0% probability that the sensitivity of REDI (median 81.3%; 95% probability interval [PI]: 55.5, 95.8) was higher than VO sensitivity (64.5%; PI: 57.9, 70.8). The specificity of REDI (median 92.9%; PI: 88.2, 96.9) was also higher compared to VO (median 69.1%; PI: 66.3, 71.8). The differences in sensitivity and specificity resulted in REDI exhibiting higher positive and negative predictive values in both high (41.3%) and low (2.6%) prevalence situations. This research illustrates the potential of remote cattle monitoring to augment conventional methods of BRD diagnosis resulting in more accurate identification of diseased cattle. Copyright © 2016 Elsevier B.V. All rights reserved.
DNA damage induced by boron neutron capture therapy is partially repaired by DNA ligase IV.
Kondo, Natsuko; Sakurai, Yoshinori; Hirota, Yuki; Tanaka, Hiroki; Watanabe, Tsubasa; Nakagawa, Yosuke; Narabayashi, Masaru; Kinashi, Yuko; Miyatake, Shin-ichi; Hasegawa, Masatoshi; Suzuki, Minoru; Masunaga, Shin-ichiro; Ohnishi, Takeo; Ono, Koji
2016-03-01
Boron neutron capture therapy (BNCT) is a particle radiation therapy that involves the use of a thermal or epithermal neutron beam in combination with a boron ((10)B)-containing compound that specifically accumulates in tumor. (10)B captures neutrons and the resultant fission reaction produces an alpha ((4)He) particle and a recoiled lithium nucleus ((7)Li). These particles have the characteristics of high linear energy transfer (LET) radiation and therefore have marked biological effects. High-LET radiation is a potent inducer of DNA damage, specifically of DNA double-strand breaks (DSBs). The aim of the present study was to clarify the role of DNA ligase IV, a key player in the non-homologous end-joining repair pathway, in the repair of BNCT-induced DSBs. We analyzed the cellular sensitivity of the mouse embryonic fibroblast cell lines Lig4-/- p53-/- and Lig4+/+ p53-/- to irradiation using a thermal neutron beam in the presence or absence of (10)B-para-boronophenylalanine (BPA). The Lig4-/- p53-/- cell line had a higher sensitivity than the Lig4+/+ p53-/-cell line to irradiation with the beam alone or the beam in combination with BPA. In BNCT (with BPA), both cell lines exhibited a reduction of the 50 % survival dose (D 50) by a factor of 1.4 compared with gamma-ray and neutron mixed beam (without BPA). Although it was found that (10)B uptake was higher in the Lig4+/+ p53-/- than in the Lig4-/- p53-/- cell line, the latter showed higher sensitivity than the former, even when compared at an equivalent (10)B concentration. These results indicate that BNCT-induced DNA damage is partially repaired using DNA ligase IV.
Wu, Ling; Tang, Hailin; Hu, Shengqiang; Xia, Yonghong; Lu, Zhixuan; Fan, Yujuan; Wang, Zixiao; Yi, Xinyao; Zhou, Feimeng; Wang, Jianxiu
2018-04-30
Murine double minute 2 (MDM2) is an oncoprotein mediating the degradation of the tumor suppressor p53 protein. The physiological levels of MDM2 protein are closely related to malignant transformation and tumor growth. In this work, the simultaneous and label-free determination of free and p53-bound MDM2 proteins from sarcoma tissue extracts was conducted using a dual-channel surface plasmon resonance (SPR) instrument. Free MDM2 protein was measured in one fluidic channel covered with the consensus double-stranded (ds)-DNA/p53 conjugate, while MDM2 bound to p53 was captured by the consensus ds-DNA immobilized onto the other channel. To achieve higher sensitivity and to confirm specificity, an MDM2-specific monoclonal antibody (2A10) was used to recognize both the free and p53-bound MDM2 proteins. The resultant method afforded a detection limit of 0.55 pM of MDM2. The amenability of the method to the analysis of free and p53-bound MDM2 proteins was demonstrated for normal and sarcoma tissue extracts from three patients. Our data reveal that both free and total MDM2 (free and bound forms combined) proteins from sarcoma tissue extracts are of much higher concentrations than those from normal tissue extracts and the p53-bound MDM2 protein only constitutes a small fraction of the total MDM2 concentration. In comparison with enzyme-linked immunosorbent assay (ELISA), the proposed method possesses higher sensitivity, is more cost-effective, and is capable of determining free and p53-bound MDM2 proteins in clinical samples.
Identifying Talent in Youth Sport: A Novel Methodology Using Higher-Dimensional Analysis
Till, Kevin; Jones, Ben L.; Cobley, Stephen; Morley, David; O'Hara, John; Chapman, Chris; Cooke, Carlton; Beggs, Clive B.
2016-01-01
Prediction of adult performance from early age talent identification in sport remains difficult. Talent identification research has generally been performed using univariate analysis, which ignores multivariate relationships. To address this issue, this study used a novel higher-dimensional model to orthogonalize multivariate anthropometric and fitness data from junior rugby league players, with the aim of differentiating future career attainment. Anthropometric and fitness data from 257 Under-15 rugby league players was collected. Players were grouped retrospectively according to their future career attainment (i.e., amateur, academy, professional). Players were blindly and randomly divided into an exploratory (n = 165) and validation dataset (n = 92). The exploratory dataset was used to develop and optimize a novel higher-dimensional model, which combined singular value decomposition (SVD) with receiver operating characteristic analysis. Once optimized, the model was tested using the validation dataset. SVD analysis revealed 60 m sprint and agility 505 performance were the most influential characteristics in distinguishing future professional players from amateur and academy players. The exploratory dataset model was able to distinguish between future amateur and professional players with a high degree of accuracy (sensitivity = 85.7%, specificity = 71.1%; p<0.001), although it could not distinguish between future professional and academy players. The validation dataset model was able to distinguish future professionals from the rest with reasonable accuracy (sensitivity = 83.3%, specificity = 63.8%; p = 0.003). Through the use of SVD analysis it was possible to objectively identify criteria to distinguish future career attainment with a sensitivity over 80% using anthropometric and fitness data alone. As such, this suggests that SVD analysis may be a useful analysis tool for research and practice within talent identification. PMID:27224653
Effect of monitor display on detection of approximal caries lesions in digital radiographs.
Isidor, S; Faaborg-Andersen, M; Hintze, H; Kirkevang, L-L; Frydenberg, M; Haiter-Neto, F; Wenzel, A
2009-12-01
The aim was to compare the accuracy of five flat panel monitors for detection of approximal caries lesions. Five flat panel monitors, Mermaid Ventura (15 inch, colour flat panel, 1024 x 768, 32 bit, analogue), Olórin VistaLine (19 inch, colour, 1280 x 1024, 32 bit, digital), Samsung SyncMaster 203B (20 inch, colour, 1024 x 768, 32 bit, analogue), Totoku ME251i (21 inch, greyscale, 1400 x 1024, 32 bit, digital) and Eizo FlexScan MX190 (19 inch, colour, 1280 x 1024, 32 bit, digital), were assessed. 160 approximal surfaces of human teeth were examined with a storage phosphor plate system (Digora FMX, Soredex) and assessed by seven observers for the presence of caries lesions. Microscopy of the teeth served as validation for the presence/absence of a lesion. The sensitivities varied between observers (range 7-25%) but the variation between the monitors was not large. The Samsung monitor obtained a significantly higher sensitivity than the Mermaid and Olórin monitors (P<0.02) and a lower specificity than the Eizo and Totoku monitors (P<0.05). There were no significant differences between any other monitors. The percentage of correct scores was highest for the Eizo monitor and significantly higher than for the Mermaid and Olórin monitors (P<0.03). There was no clear relationship between the diagnostic accuracy and the resolution or price of the monitor. The Eizo monitor was associated with the overall highest percentage of correct scores. The standard analogue flat panel monitor, Samsung, had higher sensitivity and lower specificity than some of the other monitors, but did not differ in overall accuracy for detection of carious lesions.
NASA Astrophysics Data System (ADS)
Kerr, Laura T.; Adams, Aine; O'Dea, Shirley; Domijan, Katarina; Cullen, Ivor; Hennelly, Bryan M.
2014-05-01
Raman microspectroscopy can be applied to the urinary bladder for highly accurate classification and diagnosis of bladder cancer. This technique can be applied in vitro to bladder epithelial cells obtained from urine cytology or in vivo as an optical biopsy" to provide results in real-time with higher sensitivity and specificity than current clinical methods. However, there exists a high degree of variability across experimental parameters which need to be standardised before this technique can be utilized in an everyday clinical environment. In this study, we investigate different laser wavelengths (473 nm and 532 nm), sample substrates (glass, fused silica and calcium fluoride) and multivariate statistical methods in order to gain insight into how these various experimental parameters impact on the sensitivity and specificity of Raman cytology.
Mazurek, Micah O; Lu, Frances; Symecko, Heather; Butter, Eric; Bing, Nicole M; Hundley, Rachel J; Poulsen, Marie; Kanne, Stephen M; Macklin, Eric A; Handen, Benjamin L
2017-09-01
The transition from DSM-IV to DSM-5 criteria for autism spectrum disorder (ASD) sparked considerable concern about the potential implications of these changes. This study was designed to address limitations of prior studies by prospectively examining the concordance of DSM-IV and final DSM-5 criteria on a consecutive sample of 439 children referred for autism diagnostic evaluations. Concordance and discordance were assessed using a consistent diagnostic battery. DSM-5 criteria demonstrated excellent overall specificity and good sensitivity relative to DSM-IV criteria. Sensitivity and specificity were strongest for children meeting DSM-IV criteria for autistic disorder, but poor for those meeting criteria for Asperger's disorder and pervasive developmental disorder. Higher IQ, older age, female sex, and less pronounced ASD symptoms were associated with greater discordance.
Peková, Sona; Marková, Jana; Pajer, Petr; Dvorák, Michal; Cetkovský, Petr; Schwarz, Jirí
2005-01-01
Patients with chronic lymphocytic leukemia (CLL) can relapse even after aggressive therapy and autografts. It is commonly assumed that to prevent relapse the level of minimal residual disease (MRD) should be as low as possible. To evaluate MRD, highly sensitive quantitative assays are needed. The aim of the study was to develop a robust and sensitive method for detection of the clonal immunoglobulin heavy-chain variable (IgV(H)) rearrangement in CLL and to introduce a highly sensitive and specific methodology for MRD monitoring in patients with CLL who undergo intensive treatment. As a prerequisite for MRD detection, touch-down reverse transcriptase (RT)-PCR using degenerate primers were used for the diagnostic identification of (H) gene rearrangement(s). For quantitative MRD detection in 18 patients, we employed a real-time RT-PCR assay (RQ-PCR) making use of patient-specific primers and the cost-saving Sybr-Green reporter dye (SG). For precise calibration of RQ-PCR, patient-specific IgV(H) sequences were cloned. Touch-down RT-PCR with degenerate primers allowed the successful detection of IgV(H) clonal rearrangement(s) in 252 of 257 (98.1%) diagnostic samples. Biallelic rearrangements were found in 27 of 252 (10.7%) cases. Degenerate primers used for the identification of clonal expansion at diagnosis were not sensitive enough for MRD detection. In contrast, our RQ-PCR assay using patient-specific primers and SG reached the sensitivity of 10(-)(6). We demonstrated MRD in each patient tested, including four of four patients in complete remission following autologous hematopoietic stem cell transplantation (HSCT) and three of three following allogeneic 'mini'-HSCT. Increments in MRD might herald relapse; aggressive chemotherapy could induce molecular remission. Our touch-down RT-PCR has higher efficiency to detect clonal IgV(H) rearrangements including the biallelic ones. MRD quantitation of IgV(H) expression using SG-based RQ-PCR represents a highly specific, sensitive, and economic alternative to the current quantitative methods.
Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar
2015-01-01
Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055
Kluytmans, Jan; Van Griethuysen, Arjanne; Willemse, Piet; Van Keulen, Peter
2002-01-01
Two new selective media, oxacillin resistance screening agar base (ORSAB) and CHROMagar Staph aureus (CSA), were evaluated for identification of Staphylococcus aureus and for screening of methicillin resistance by addition of antimicrobial agents to these media. A well-defined collection consisting of 1,140 staphylococci was used. A total of 624 were S. aureus, of which 358 were methicillin susceptible and 266 were methicillin resistant, and 516 were coagulase-negative staphylococci. The methicillin-resistant S. aureus (MRSA) strains were selected based on the results of phage typing; 247 different types were included in the analysis. For identification of S. aureus, both media performed better after 24 h than after 48 h. The sensitivities at 24 h were comparable (CSA, 98.6%; ORSAB, 97.1%), but the specificity of CSA was significantly higher (CSA, 97.1%; ORSAB, 92.1%). For screening of methicillin resistance, antibiotic supplements were added to both media. The sensitivity was lower after 24 h (CSA, 58.6%; ORSAB, 84.2%) and increased significantly after 48 h (CSA, 77.5%; ORSAB, 91.4%). At both time intervals ORSAB was significantly more sensitive than CSA. However, the specificities of both media were high after 24 h (CSA, 99.1%; ORSAB, 98.3%) and decreased significantly after 48 h of incubation (CSA, 94.7%; ORSAB, 95.5%). In conclusion, for identification of S. aureus, CSA is more accurate than ORSAB because of a significantly higher specificity. For screening of MRSA, ORSAB performs better than CSA, but the usefulness in clinical practice is limited because a significant number of strains are not detected. PMID:12089266
Napolitano, Andrea; Antoine, Daniel J; Pellegrini, Laura; Baumann, Francine; Pagano, Ian; Pastorino, Sandra; Goparaju, Chandra M; Prokrym, Kirill; Canino, Claudia; Pass, Harvey I; Carbone, Michele; Yang, Haining
2016-06-15
To determine whether serum levels of high mobility group box protein 1 (HMGB1) could differentiate malignant mesothelioma patients, asbestos-exposed individuals, and unexposed controls. Hyperacetylated and nonacetylated HMGB1 (together referred to as total HMGB1) were blindly measured in blood collected from malignant mesothelioma patients (n = 22), individuals with verified chronic asbestos exposure (n = 20), patients with benign pleural effusions (n = 13) or malignant pleural effusions not due to malignant mesothelioma (n = 25), and healthy controls (n = 20). Blood levels of previously proposed malignant mesothelioma biomarkers fibulin-3, mesothelin, and osteopontin were also measured in nonhealthy individuals. HMGB1 serum levels reliably distinguished malignant mesothelioma patients, asbestos-exposed individuals, and unexposed controls. Total HMGB1 was significantly higher in malignant mesothelioma patients and asbestos-exposed individuals compared with healthy controls. Hyperacetylated HMGB1 was significantly higher in malignant mesothelioma patients compared with asbestos-exposed individuals and healthy controls, and did not vary with tumor stage. At the cut-off value of 2.00 ng/mL, the sensitivity and specificity of serum hyperacetylated HMGB1 in differentiating malignant mesothelioma patients from asbestos-exposed individuals and healthy controls was 100%, outperforming other previously proposed biomarkers. Combining HMGB1 and fibulin-3 provided increased sensitivity and specificity in differentiating malignant mesothelioma patients from patients with cytologically benign or malignant non-mesothelioma pleural effusion. Our results are significant and clinically relevant as they provide the first biomarker of asbestos exposure and indicate that hyperacetylated HMGB1 is an accurate biomarker to differentiate malignant mesothelioma patients from individuals occupationally exposed to asbestos and unexposed controls. A trial to independently validate these findings will start soon. Clin Cancer Res; 22(12); 3087-96. ©2016 AACR. ©2016 American Association for Cancer Research.