Sample records for higher total dose

  1. Maximum dose rate is a determinant of hypothyroidism after 131I therapy of Graves' disease but the total thyroid absorbed dose is not.

    PubMed

    Krohn, Thomas; Hänscheid, Heribert; Müller, Berthold; Behrendt, Florian F; Heinzel, Alexander; Mottaghy, Felix M; Verburg, Frederik A

    2014-11-01

    The determinants of successful (131)I therapy of Graves' disease (GD) are unclear. To relate dosimetry parameters to outcome of therapy to identify significant determinants eu- and/or hypothyroidism after (131)I therapy in patients with GD. A retrospective study in which 206 Patients with GD treated in University Hospital between November 1999 and January 2011. All received (131)I therapy aiming at a total absorbed dose to the thyroid of 250 Gy based on pre-therapeutic dosimetry. Post-therapy dosimetric thyroid measurements were performed twice daily until discharge. From these measurements, thyroid (131)I half-life, the total thyroid absorbed dose, and the maximum dose rate after (131)I administration were calculated. In all, 48.5% of patients were hypothyroid and 28.6% of patients were euthyroid after (131)I therapy. In univariate analysis, nonhyperthyroid and hyperthyroid patients only differed by sex. A lower thyroid mass, a higher activity per gram thyroid tissue, a shorter effective thyroidal (131)I half-life, and a higher maximum dose rate, but not the total thyroid absorbed dose, were significantly associated with hypothyroidism. In multivariate analysis, the maximum dose rate remained the only significant determinant of hypothyroidism (P < .001). Maximum dose rates of 2.2 Gy/h and higher were associated with a 100% hypothyroidism rate. Not the total thyroid absorbed dose, but the maximum dose rate is a determinant of successfully achieving hypothyroidism in Graves' disease. Dosimetric concepts aiming at a specific total thyroid absorbed dose will therefore require reconsideration if our data are confirmed prospectively.

  2. Novel Measure of Opioid Dose and Costs of Care for Diabetes Mellitus: Opioid Dose and Health Care Costs.

    PubMed

    Gautam, Santosh; Franzini, Luisa; Mikhail, Osama I; Chan, Wenyaw; Turner, Barbara J

    2016-03-01

    Diabetes mellitus (DM) has well known costly complications but we hypothesized that costs of care for chronic pain treated with opioid analgesic (OA) medications would also be substantial. In a statewide, privately insured cohort of 29,033 adults aged 18 to 64 years with DM and noncancer pain who filled OA prescription(s) from 2008 to 2012, our outcomes were costs for specific health care services and total costs per 6-month intervals after the first filled OA prescription. Average daily OA dose (4 categories) and total dose (quartiles) in morphine-equivalent milligrams were calculated per 6-month interval after the first OA prescription and combined into a novel OA dose measure. Associations of OA measures with costs of care (n = 126,854 6-month intervals) were examined using generalized estimating equations adjusted for clinical conditions, psychotherapeutic drugs, and DM treatment. Incremental costs for each type of health care service and total cost of care increased progressively with average daily and total OA dose versus no OAs. The combined OA measure identified the highest incremental total costs per 6-month interval that were increased by $8,389 for 50- to 99-mg average daily dose plus >900 mg total dose and, by $9,181 and $9,958 respectively, for ≥100 mg average daily dose plus 301- to 900-mg or >900 mg total dose. In this statewide DM cohort, total health care costs per 6-month interval increased progressively with higher average daily OA dose and with total OA dose but the greatest increases of >$8,000 were distinguished by combinations of higher average daily and total OA doses. The higher costs of care for opioid-treated patients appeared for all types of services and likely reflects multiple factors including morbidity from the underlying cause of pain, care and complications related to opioid use, and poorer control of diabetes as found in other studies. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  3. Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation.

    PubMed

    Saltybaeva, Natalia; Krauss, Andreas; Alkadhi, Hatem

    2017-03-01

    Purpose To calculate the effect of localizer radiography projections to the total radiation dose, including both the dose from localizer radiography and that from subsequent chest computed tomography (CT) with tube current modulation (TCM). Materials and Methods An anthropomorphic phantom was scanned with 192-section CT without and with differently sized breast attachments. Chest CT with TCM was performed after one localizer radiographic examination with anteroposterior (AP) or posteroanterior (PA) projections. Dose distributions were obtained by means of Monte Carlo simulations based on acquired CT data. For Monte Carlo simulations of localizer radiography, the tube position was fixed at 0° and 180°; for chest CT, a spiral trajectory with TCM was used. The effect of tube start angles on dose distribution was investigated with Monte Carlo simulations by using TCM curves with fixed start angles (0°, 90°, and 180°). Total doses for lungs, heart, and breast were calculated as the sum of the dose from localizer radiography and CT. Image noise was defined as the standard deviation of attenuation measured in 14 circular regions of interest. The Wilcoxon signed rank test, paired t test, and Friedman analysis of variance were conducted to evaluate differences in noise, TCM curves, and organ doses, respectively. Results Organ doses from localizer radiography were lower when using a PA instead of an AP projection (P = .005). The use of a PA projection resulted in higher TCM values for chest CT (P < .001) owing to the higher attenuation (P < .001) and thus resulted in higher total organ doses for all investigated phantoms and protocols (P < .001). Noise in CT images was lower with PA localizer radiography than with AP localizer radiography (P = .03). The use of an AP projection allowed for total dose reductions of 16%, 15%, and 12% for lungs, breast, and heart, respectively. Differences in organ doses were not related to tube start angles (P = .17). Conclusion The total organ doses are higher when using PA projection localizer radiography owing to higher TCM values, whereas the organ doses from PA localizer radiography alone are lower. Thus, PA localizer radiography should be used in combination with reduced reference tube current at subsequent chest CT. © RSNA, 2016 Online supplemental material is available for this article.

  4. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    NASA Technical Reports Server (NTRS)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  5. Differences in botulinum toxin dosing between patients with adductor spasmodic dysphonia and essential voice tremor.

    PubMed

    Orbelo, Diana M; Duffy, Joseph R; Hughes Borst, Becky J; Ekbom, Dale; Maragos, Nicolas E

    2014-01-01

    To explore possible dose differences in average botulinum toxin (BTX) given to patients with adductor spasmodic dysphonia (ADSD) compared with patients with essential voice tremor (EVT). A retrospective study compared the average BTX dose injected in equal doses to the thyroarytenoid (TA) muscles of 51 patients with ADSD with 52 patients with EVT. Those with ADSD received significantly higher total doses (6.80 ± 2.79 units) compared with those with EVT (5.02 ± 1.65 units). Dose at time of first injection, age at time of first injection, gender, year of first injection, and average time between injections were included in multivariate analysis but did not interact with total average dose findings. Patients with ADSD may need relatively higher doses of BTX injections to bilateral TA muscles compared with patients with EVT. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  6. ELDRS Characterization for a Very High Dose Mission

    NASA Technical Reports Server (NTRS)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  7. Analysis of buprenorphine/naloxone dosing impact on treatment duration, resource use and costs in the treatment of opioid-dependent adults: a retrospective study of US public and private health care claims.

    PubMed

    Khemiri, Amine; Kharitonova, Elizaveta; Zah, Vladimir; Ruby, Jane; Toumi, Mondher

    2014-09-01

    The buprenorphine/naloxone combination is used to treat the chronic relapsing disorder of opioid dependence. Adequate dosing levels are important to control cravings, prevent withdrawal syndrome, and maintain patients in treatment. The objective of this study was to estimate the impact of dosing on treatment persistence, resource utilization, and total direct health care costs. A retrospective cohort analysis was performed using administrative claims extracted from the MarketScan and Clinformatics databases from January 2007 to June and November 2012. Patients initiating treatment with buprenorphine/naloxone were classified into 2 groups based on the prescribed average dose over the entire treatment period and matched by multiple criteria. The threshold for differentiating the dosing groups was set at 15 and 15.7 mg/day for publicly and privately insured patients, respectively. Resource utilization and related costs were calculated over the 12-month period after the treatment initiation. Patient characteristics at baseline were considerably different between the privately and publicly insured patients. Publicly insured patients were slightly younger (33.1 vs 34.3 years old for privately insured) and had a higher prevalence of mental disorders (70.9% vs 64.9%). In both groups, patients treated with higher doses (> 15 mg and > 15.7 mg per day for publicly and privately insured patients, respectively) had lower risk of discontinuation (public: 11% lower; private: 9% lower) and lower probability of a psychiatric hospitalization than patients treated with lower doses (public: 17% lower; private: 41% lower). Total costs were comparable between the 2 groups (public: $14 600; private: $21 000) despite the expected higher cost of pharmacy in the higher-dose group. Treatment with higher doses of buprenorphine/naloxone was associated with a longer time to treatment discontinuation, less resource use, and lower total medical costs despite higher pharmacy acquisition cost.

  8. Inhaled corticosteroids and asthma control in adult-onset asthma: 12-year follow-up study.

    PubMed

    Vähätalo, Iida; Ilmarinen, Pinja; Tuomisto, Leena E; Niemelä, Onni; Kankaanranta, Hannu

    2018-04-01

    Prescribed inhaled corticosteroid (ICS) doses in asthma have been studied in cross-sectional settings whereas long-term follow-up studies have not been carried out. To evaluate prescribed medication longitudinally by calculating cumulative ICS doses and dose changes in a cohort of new-onset adult asthma during 12 years and in different groups of asthma control. A total of 203 patients were followed for 12 years as part of Seinäjoki Adult Asthma Study (SAAS). All asthma-related visits and prescribed medication over the study period were collected from medical records. Total cumulative ICS dose for the 12-year follow-up period was 3.4g (±SEM 0.1) per patient. Both respiratory specialists and GPs prescribed step-ups and step-downs in ICS treatment and in total 649 dose changes were noted during the follow-up (median 3(1-5) per patient). Patients with uncontrolled asthma received higher ICS doses throughout the follow-up period, and therefore, cumulative 12-year ICS dose (3.8g ± SEM 0.2) in this group was higher than that in those with partially controlled (3.4g ± SEM 0.2) or controlled disease (2.9g ± SEM 0.2) (p = 0.0001). Patients with uncontrolled asthma were also prescribed a higher number of ICS dose changes than patients with controlled disease. Despite frequent dose changes and high ICS doses during the 12-year follow-up, the level of asthma control remained poor in patients with uncontrolled asthma. This suggests that high ICS doses may not be effective enough for management of disease in patients with uncontrolled adult-onset asthma and novel targeted treatments are required. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. High dose psilocybin is associated with positive subjective effects in healthy volunteers.

    PubMed

    Nicholas, Christopher R; Henriquez, Kelsey M; Gassman, Michele C; Cooper, Karen M; Muller, Daniel; Hetzel, Scott; Brown, Randall T; Cozzi, Nicholas V; Thomas, Chantelle; Hutson, Paul R

    2018-06-01

    The aim of the current study was to investigate the relationship between escalating higher doses of psilocybin and the potential psilocybin occasioned positive subjective effects. Healthy participants ( n=12) were given three escalating doses of oral psilocybin (0.3 mg/kg; 0.45 mg/kg; 0.6 mg/kg) or (18.8-36.6 mg; 27.1-54.0 mg; 36.3-59.2 mg) a minimum of four weeks apart in a supervised setting. Blood and urine samples, vital signs, and electrocardiograms were obtained. Subjective effects were assessed using the Mystical Experience Questionnaire and Persisting Effects Questionnaire. There was a significant linear dose-related response in Mystical Experience Questionnaire total score and the transcendence of time and space subscale, but not in the rate of a complete mystical experience. There was also a significant difference between dose 3 compared to dose 1 on the transcendence of time and space subscale, while no dose-related differences were found for Mystical Experience Questionnaire total scores or rate of a mystical experience. Persisting Effects Questionnaire positive composite scores 30 days after completion of the last dose were significantly higher than negative composite scores. Persisting Effects Questionnaire results revealed a moderate increase in sense of well-being or life satisfaction on average that was associated with the maximum Mystical Experience Questionnaire total score. Pharmacokinetic measures were associated with dose but not with Mystical Experience Questionnaire total scores or rate of a mystical experience. High doses of psilocybin elicited subjective effects at least as strong as the lower doses and resulted in positive persisting subjective effects 30 days after, indicating that a complete mystical experience was not a prerequisite for positive outcomes.

  10. The lateral plane delivers higher dose than the frontal plane in biplane cardiac catheterization systems.

    PubMed

    Aldoss, Osamah; Patel, Sonali; Harris, Kyle; Divekar, Abhay

    2015-06-01

    The objective of the study is to compare radiation dose between the frontal and lateral planes in a biplane cardiac catheterization laboratory. Tube angulation progressively increases patient and operator radiation dose in single-plane cardiac catheterization laboratories. This retrospective study captured biplane radiation dose in a pediatric cardiac catheterization laboratory between April 2010 and January 2014. Raw and time-indexed fluoroscopic, cineangiographic and total (fluoroscopic + cineangiographic) air kerma (AK, mGy) and kerma area product (PKA, µGym(2)/Kg) for each plane were compared. Data for 716 patients were analyzed: 408 (56.98 %) were male, the median age was 4.86 years, and the median weight was 17.35 kg. Although median beam-on time (minutes) was 4.2 times greater in the frontal plane, there was no difference in raw median total PKA between the two planes. However, when indexed to beam-on time, the lateral plane had a higher median-indexed fluoroscopic (0.75 vs. 1.70), cineangiographic (16.03 vs. 24.92), and total (1.43 vs. 5.15) PKA (p < 0.0001). The median time-indexed total PKA in the lateral plane is 3.6 times the frontal plane. This is the first report showing that the lateral plane delivers a higher dose than the frontal plane per unit time. Operators should consciously reduce the lateral plane beam-on time and incorporate this practice in radiation reduction protocols.

  11. Multi-level effects of low dose rate ionizing radiation on southern toad, Anaxyrus [Bufo] terrestris

    DOE PAGES

    Stark, Karolina; Scott, David E.; Tsyusko, Olga; ...

    2015-04-30

    Despite their potential vulnerability to contaminants from exposure at multiple life stages, amphibians are one of the least studied groups of vertebrates in ecotoxicology, and research on radiation effects in amphibians is scarce. We used multiple endpoints to assess the radiosensitivity of the southern toad ( Anaxyrus [Bufo] terrestris) during its pre-terrestrial stages of development –embryonic, larval, and metamorphic. Toads were exposed, from several hours after oviposition through metamorphosis (up to 77 days later), to four low dose rates of ¹³⁷Cs at 0.13, 2.4, 21, and 222 mGy d⁻¹, resulting in total doses up to 15.8 Gy. Radiation treatments didmore » not affect hatching success of embryos, larval survival, or the length of the larval period. The individual family variation in hatching success of embryos was larger than the radiation response. In contrast, newly metamorphosed individuals from the higher dose-rate treatments had higher mass and mass/length body indices, a measure which may relate to higher post-metamorphic survival. The increased mass and index at higher dose rates may indicate that the chronic, low dose rate radiation exposures triggered secondary responses. Additionally, the increases in growth were linked to a decrease in DNA damage (as measured by the Comet Assay) in red blood cells at a dose rate of 21mGy d⁻¹ and a total dose of 1.1 Gy. In conclusion, the complex effects of low dose rates of ionizing radiation may trigger growth and cellular repair mechanisms in amphibian larvae.« less

  12. High Dose Hyperfractionated Radiotherapy for Adults with Glioblastomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koukourakis, Michael; Scarlatos, John; Yiannakakis, Dimitrios

    2015-01-15

    From 1989 to 1991, 27 patients with glioblastoma multiforme or anaplastic astrocytoma of the brain were treated with radiotherapy. Fifteen of twenty-seven patients were treated through limited volume fields, with a thrice-a-day (1.1 Gy/f) or twice-a-day (1.4 Gy/f) hyperfractionated regimen to a total physical dose of 62–92 Gy (median dose 76 Gy). The remaining 12 were treated with whole brain irradiation (40 Gy of total conventionally fractionated dose) and a localised boost to a total dose of 60 Gy. The hyperfractionated regimen was well tolerated and there was no sign of increased brain oedema to indicate the insertion of amore » split. Of six patients who received a NTD10 (normalised total dose for α/β =10) higher than 71 Gy, five showed CR (83% CR rate) versus three of 21 patients who received a lower NTD10 (14% CR rate). For 13 patients who received a NTD10 higher than 66 Gy, the 18-months survival was 61% (8/13) versus 28% (4/14) for 14 patients who received a NTD10 less than 66 Gy. As far as the late morbidity is concerned, of six patients treated with 76-92 Gy of physical dose, none died because of radiation-induced brain necrosis within 18-42 months of follow-up, and three of them are without evidence of disease 18-31 months after the end of radiation treatment. None of our 15 patients who received less than whole brain irradiation relapsed outside the radiation portals. The present study strongly suggests the use of limited volume hyperfractionated radiotherapy schemes, so as to increase the local tumor dose (NTD10) to values higher than 79 Gy, at the same time keeping the NTD2 (NTD for α/β = 2) below 68 Gy.« less

  13. Biological dosimetry in a group of radiologists by the analysis of dicentrics and translocations.

    PubMed

    Montoro, A; Rodríguez, P; Almonacid, M; Villaescusa, J I; Verdú, G; Caballín, M R; Barrios, L; Barquinero, J F

    2005-11-01

    The results of a cytogenetic study carried out in a group of nine radiologists are presented. Chromosome aberrations were detected by fluorescence plus Giemsa staining and fluorescence in situ hybridization. Dose estimates were obtained by extrapolating the yield of dicentrics and translocations to their respective dose-effect curves. In seven individuals, the 95% confidence limits of the doses estimated by dicentrics did not include 0 Gy. The 99 dicentrics observed in 17,626 cells gave a collective estimated dose of 115 mGy (95% confidence limits 73-171). For translocations, five individuals had estimated doses that were clearly higher than the total accumulated recorded dose. The 82 total apparently simple translocations observed in 9722 cells gave a collective estimated dose of 275 mGy (132-496). The mean genomic frequencies (x100 +/- SE) of complete and total apparently simple translocations observed in the group of radiologists (1.91 +/- 0.30 and 2.67 +/- 0.34, respectively) were significantly higher than those observed in a matched control group (0.53 +/- 0.10 and 0.87 +/- 0.13, P < 0.01 in both cases) and in another occupationally exposed matched group (0.79 +/- 0.12 and 1.14 +/-0.14, P < 0.03 and P < 0.01, respectively). The discrepancies observed between the physically recorded doses and the biologically estimated doses indicate that the radiologists did not always wear their dosimeters or that the dosimeters were not always in the radiation field.

  14. Toxic influence of key organic soil pollutants on the total flavonoid content in wheat leaves

    PubMed Central

    Copaciu, Florina; Opriş, Ocsana; Niinemets, Ülo; Copolovici, Lucian

    2018-01-01

    Textile dyes and antibiotics are two main classes of environmental pollutants which could be found in soil and water. Those persistent pollutants can have a negative influence on plant growth and development and affect the level of secondary metabolites. In the present work we studied the effect of textile dyes and antibiotics on total leaf flavonoid contents in wheat (Triticum aestivum L.). Contaminant solutions were applied daily using concentrations of 0.5 mg L–1 (lower) and 1.5 mg L–1 (higher dose) for either one or two weeks. We observed that exposure to the higher concentration of textile dyes resulted in a reduction in flavonoid content while antibiotics enhanced flavonoid contents at lower doses of exposure, and reduced at higher doses of exposure. These results suggest that diffuse chronic pollution by artificial organic contaminants can importantly alter antioxidative capacity of plants. PMID:29386693

  15. Toxic influence of key organic soil pollutants on the total flavonoid content in wheat leaves.

    PubMed

    Copaciu, Florina; Opriş, Ocsana; Niinemets, Ülo; Copolovici, Lucian

    2016-06-01

    Textile dyes and antibiotics are two main classes of environmental pollutants which could be found in soil and water. Those persistent pollutants can have a negative influence on plant growth and development and affect the level of secondary metabolites. In the present work we studied the effect of textile dyes and antibiotics on total leaf flavonoid contents in wheat ( Triticum aestivum L.). Contaminant solutions were applied daily using concentrations of 0.5 mg L -1 (lower) and 1.5 mg L -1 (higher dose) for either one or two weeks. We observed that exposure to the higher concentration of textile dyes resulted in a reduction in flavonoid content while antibiotics enhanced flavonoid contents at lower doses of exposure, and reduced at higher doses of exposure. These results suggest that diffuse chronic pollution by artificial organic contaminants can importantly alter antioxidative capacity of plants.

  16. Strategies for systemic radiotherapy of micrometastases using antibody-targeted 131I.

    PubMed

    Wheldon, T E; O'Donoghue, J A; Hilditch, T E; Barrett, A

    1988-02-01

    A simple analysis is developed to evaluate the likely effectiveness of treatment of micrometastases by antibody-targeted 131I. Account is taken of the low levels of tumour uptake of antibody-conjugated 131I presently achievable and of the "energy wastage" in targeting microscopic tumours with a radionuclide whose disintegration energy is widely dissipated. The analysis shows that only modest doses can be delivered to micrometastases when total body dose is restricted to levels which allow recovery of bone marrow. Much higher doses could be delivered to micrometastases when bone marrow rescue is used. A rationale is presented for targeted systemic radiotherapy used in combination with external beam total body irradiation (TBI) and bone marrow rescue. This has some practical advantages. The effect of the targeted component is to impose a biological non-uniformity on the total body dose distribution with regions of high tumour cell density receiving higher doses. Where targeting results in high doses to particular normal organs (e.g. liver, kidney) the total dose to these organs could be kept within tolerable limits by appropriate shielding of the external beam radiation component of the treatment. Greater levels of tumour cell kill should be achievable by the combination regime without any increase in normal tissue damage over that inflicted by conventional TBI. The predicted superiority of the combination regime is especially marked for tumours just below the threshold for detectability (e.g. approximately 1 mm-1 cm diameter). This approach has the advantage that targeted radiotherapy provides only a proportion of the total body dose, most of which is given by a familiar technique. The proportion of dose given by the targeted component could be increased as experience is gained. The predicted superiority of the combination strategy should be experimentally testable using laboratory animals. Clinical applications should be cautiously approached, with due regard to the limitations of the theoretical analysis.

  17. High-dose versus standard-dose radiotherapy with concurrent chemotherapy in stages II-III esophageal cancer.

    PubMed

    Suh, Yang-Gun; Lee, Ik Jae; Koom, Wong Sub; Cha, Jihye; Lee, Jong Young; Kim, Soo Kon; Lee, Chang Geol

    2014-06-01

    In this study, we investigated the effects of radiotherapy ≥60 Gy in the setting of concurrent chemo-radiotherapy for treating patients with Stages II-III esophageal cancer. A total of 126 patients treated with 5-fluorouracilbased concurrent chemo-radiotherapy between January 1998 and February 2008 were retrospectively reviewed. Among these patients, 49 received a total radiation dose of <60 Gy (standard-dose group), while 77 received a total radiation dose of ≥60 Gy (high-dose group). The median doses in the standard- and high-dose groups were 54 Gy (range, 45-59.4 Gy) and 63 Gy (range, 60-81 Gy), respectively. The high-dose group showed significantly improved locoregional control (2-year locoregional control rate, 69 versus 32%, P < 0.01) and progression-free survival (2-year progression-free survival, 47 versus 20%, P = 0.01) than the standard-dose group. Median overall survival in the high- and the standard-dose groups was 28 and 18 months, respectively (P = 0.26). In multivariate analysis, 60 Gy or higher radiotherapy was a significant prognostic factor for improved locoregional control, progression-free survival and overall survival. No significant differences were found in frequencies of late radiation pneumonitis, post-treatment esophageal stricture or treatment-related mortality between the two groups. High-dose radiotherapy of 60 Gy or higher with concurrent chemotherapy improved locoregional control and progression-free survival without a significant increase of in treatment-related toxicity in patients with Stages II-III esophageal cancer. Our study could provide the basis for future randomized clinical trials. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Exposure to Hexavalent Chromium Resulted in Significantly Higher Tissue Chromium Burden Compared With Trivalent Chromium Following Similar Oral Doses to Male F344/N Rats and Female B6C3F1 Mice

    PubMed Central

    Collins, Bradley J.; Stout, Matthew D.; Levine, Keith E.; Kissling, Grace E.; Fennell, Timothy R.; Walden, Ramsey; Abdo, Kamal; Pritchard, John B.; Fernando, Reshan A.; Burka, Leo T.; Hooth, Michelle J.

    2010-01-01

    In National Toxicology Program 2-year studies, hexavalent chromium [Cr(VI)] administered in drinking water was clearly carcinogenic in male and female rats and mice, resulting in small intestine epithelial neoplasms in mice at a dose equivalent to or within an order of magnitude of human doses that could result from consumption of chromium-contaminated drinking water, assuming that dose scales by body weight3/4 (body weight raised to the 3/4 power). In contrast, exposure to trivalent chromium [Cr(III)] at much higher concentrations may have been carcinogenic in male rats but was not carcinogenic in mice or female rats. As part of these studies, total chromium was measured in tissues and excreta of additional groups of male rats and female mice. These data were used to infer the uptake and distribution of Cr(VI) because Cr(VI) is reduced to Cr(III) in vivo, and no methods are available to speciate tissue chromium. Comparable external doses resulted in much higher tissue chromium concentrations following exposure to Cr(VI) compared with Cr(III), indicating that a portion of the Cr(VI) escaped gastric reduction and was distributed systemically. Linear or supralinear dose responses of total chromium in tissues were observed following exposure to Cr(VI), indicating that these exposures did not saturate gastric reduction capacity. When Cr(VI) exposure was normalized to ingested dose, chromium concentrations in the liver and glandular stomach were higher in mice, whereas kidney concentrations were higher in rats. In vitro studies demonstrated that Cr(VI), but not Cr(III), is a substrate of the sodium/sulfate cotransporter, providing a partial explanation for the greater absorption of Cr(VI). PMID:20843897

  19. Exposure to hexavalent chromium resulted in significantly higher tissue chromium burden compared with trivalent chromium following similar oral doses to male F344/N rats and female B6C3F1 mice.

    PubMed

    Collins, Bradley J; Stout, Matthew D; Levine, Keith E; Kissling, Grace E; Melnick, Ronald L; Fennell, Timothy R; Walden, Ramsey; Abdo, Kamal; Pritchard, John B; Fernando, Reshan A; Burka, Leo T; Hooth, Michelle J

    2010-12-01

    In National Toxicology Program 2-year studies, hexavalent chromium [Cr(VI)] administered in drinking water was clearly carcinogenic in male and female rats and mice, resulting in small intestine epithelial neoplasms in mice at a dose equivalent to or within an order of magnitude of human doses that could result from consumption of chromium-contaminated drinking water, assuming that dose scales by body weight(3/4) (body weight raised to the 3/4 power). In contrast, exposure to trivalent chromium [Cr(III)] at much higher concentrations may have been carcinogenic in male rats but was not carcinogenic in mice or female rats. As part of these studies, total chromium was measured in tissues and excreta of additional groups of male rats and female mice. These data were used to infer the uptake and distribution of Cr(VI) because Cr(VI) is reduced to Cr(III) in vivo, and no methods are available to speciate tissue chromium. Comparable external doses resulted in much higher tissue chromium concentrations following exposure to Cr(VI) compared with Cr(III), indicating that a portion of the Cr(VI) escaped gastric reduction and was distributed systemically. Linear or supralinear dose responses of total chromium in tissues were observed following exposure to Cr(VI), indicating that these exposures did not saturate gastric reduction capacity. When Cr(VI) exposure was normalized to ingested dose, chromium concentrations in the liver and glandular stomach were higher in mice, whereas kidney concentrations were higher in rats. In vitro studies demonstrated that Cr(VI), but not Cr(III), is a substrate of the sodium/sulfate cotransporter, providing a partial explanation for the greater absorption of Cr(VI).

  20. Approximate distribution of dose among foetal organs for radioiodine uptake via placenta transfer

    NASA Astrophysics Data System (ADS)

    Millard, R. K.; Saunders, M.; Palmer, A. M.; Preece, A. W.

    2001-11-01

    Absorbed radiation doses to internal foetal organs were calculated according to the medical internal radiation dose (MIRD) technique in this study. Anthropomorphic phantoms of the pregnant female as in MIRDOSE3 enabled estimation of absorbed dose to the whole foetus at two stages of gestation. Some foetal organ self-doses could have been estimated by invoking simple spherical models for thyroid, liver, etc, but we investigated the use of the MIRDOSE3 new-born phantom as a surrogate for the stage 3 foetus, scaled to be compatible with total foetal body mean absorbed dose/cumulated activity. We illustrate the method for obtaining approximate dose distribution in the foetus near term following intake of 1 MBq of 123I, 124I, 125I or 131I as sodium iodide by the mother using in vivo biodistribution data examples from a good model of placenta transfer. Doses to the foetal thyroid of up to 1.85 Gy MBq-1 were predicted from the 131I uptake data. Activity in the foetal thyroid was the largest contributor to absorbed dose in the foetal body, brain, heart and thymus. Average total doses to the whole foetus ranged from 0.16 to 1.2 mGy MBq-1 for stages 1 and 3 of pregnancy using the MIRDOSE3 program, and were considerably higher than those predicted from the maternal contributions alone. Doses to the foetal thymus and stomach were similar, around 2-3 mGy MBq-1. Some foetal organ doses from the radioiodides were ten times higher than to the corresponding organs of the mother, and up to 100 times higher to the thyroid. The fraction of activity uptakes in foetal organs were distributed similarly to the maternal ones.

  1. Testicular toxicity in cannabis extract treated mice: association with oxidative stress and role of antioxidant enzyme systems.

    PubMed

    Mandal, Tapas K; Das, Nildari S

    2010-02-01

    Intraperitoneal injection of cannabis extract at low doses (total doses ranging from 40 mg to 60 mg per mouse) induced adverse effect on testes and oxidative stress. At low doses, there was a significant increase in lipid peroxidation and decrease in testicular lipid content, but the effects were significantly less at higher doses and at the withdrawal of cannabis treatment (recovery dose). There was a marked decrease in antioxidant enzyme profiles (superoxide dismutase, catalase and glutathione peroxidase) and glutathione content at low doses, but these effects were higher at higher dose and at withdrawal of the treatment (recovery effect). Histology revealed significant shrinkage of tubular diameter and detrimental changes in seminiferous epithelium of testis with resulting lowered serum testosterone and pituitary gonadotropins (follicular stimulating [FSH] and luteinizing hormones [LH]) levels at low doses. But at higher doses and particularly at withdrawal of the treatment, regression of various germ cell layers of testes through the revival of testosterone hormone and pituitary gonadotropins (FSH and LH) were observed, indicating that recovery effects on testes became operative possibly through the corrective measure of endogenous testicular antioxidant enzymes profiles and pituitary gonadotropins hormones feedback mechanisms.

  2. Sun-Induced Changes in Stratum Corneum Function Are Gender and Dose Dependent in a Chinese Population

    PubMed Central

    Liu, Z.; Fluhr, J.W.; Song, S.P.; Sun, Z.; Wang, H.; Shi, Y.J.; Elias, P.M.; Man, M.-Q.

    2010-01-01

    Previous studies have demonstrated that UVB radiation changes the epidermal permeability barrier and stratum corneum (SC) hydration. It is well known that sun exposure causes erythema, sunburn and melanoma. However, whether daily sun exposure alters SC integrity and epidermal permeability barrier function is largely unknown, especially in Chinese subjects. In the present study, we assess the SC integrity, SC hydration and epidermal permeability barrier function following various doses of sun exposure. A total of 258 subjects (124 males and 134 females) aged 18–50 years were enrolled. A multifunctional skin physiology monitor (Courage & Khazaka MPA5) was used to measure SC hydration and transepidermal water loss (TEWL) on the forearms. In males, basal TEWL was higher with higher doses of sun exposure than with lower doses and control, whereas in females, basal TEWL was higher with lower doses of sun exposure than with higher doses and control. In the group with higher doses of sun exposure, TEWL in females was significantly lower than that in males. The barrier recovery was faster in females than in males in both control and lower-dose groups. In both males and females, barrier recovery was delayed with higher doses of sun exposure. In males, sun exposure did not alter SC hydration, while in females SC hydration was lower with lower doses of sun exposure as compared with control and higher doses of sun exposure. These results demonstrated that sun-induced changes in SC function and SC hydration vary with gender and the extent of sun exposure. PMID:20571289

  3. Total folate and unmetabolized folic acid in the breast milk of a cross-section of Canadian women.

    PubMed

    Page, Rachael; Robichaud, André; Arbuckle, Tye E; Fraser, William D; MacFarlane, Amanda J

    2017-05-01

    Background: Folate requirements increase during pregnancy and lactation. It is recommended that women who could become pregnant, are pregnant, or are lactating consume a folic acid (FA)-containing supplement. Objectives: We sought to determine breast-milk total folate and unmetabolized folic acid (UMFA) contents and their relation with FA-supplement use and doses in a cohort of Canadian mothers who were enrolled in the MIREC (Maternal-Infant Research on Environmental Chemicals) study. Design: Breast-milk tetrahydrofolate (THF), 5-methyl-THF, 5-formyl-THF, 5,10-methenyl-THF, and UMFA were measured with the use of liquid chromatography-tandem mass spectrometry ( n = 561). Total daily supplemental FA intake was based on self-reported FA-supplement use. Results: UMFA was detectable in the milk of 96.1% of the women. Total daily FA intake from supplements was associated with breast folate concentration and species. Breast-milk total folate was 18% higher ( P < 0.001) in supplement users ( n = 401) than in nonusers ( n = 160), a difference driven by women consuming >400 μg FA/d ( P ≤ 0.004). 5-Methyl-THF was 19% lower ( P < 0.001) and UMFA was 126% higher ( P < 0.001) in supplement users than in nonusers. Women who consumed >400 μg FA/d had proportionally lower 5-methyl-THF and higher UMFA than did women who consumed ≤400 μg FA/d. Conclusions: FA-supplement use was associated with modestly higher breast-milk total folate. Detectable breast-milk UMFA was nearly ubiquitous, including in women who did not consume an FA supplement. Breast-milk UMFA was proportionally higher than 5-methyl-THF in women who consumed >400 μg FA/d, thereby suggesting that higher doses exceed the physiologic capacity to metabolize FA and result in the preferential uptake of FA in breast milk. Therefore, FA-supplement doses >400 μg may not be warranted, especially in populations for whom FA fortification is mandatory. © 2017 American Society for Nutrition.

  4. Comparison between in vivo dosimetry and barium contrast technique for prediction of rectal complications in high-dose-rate intracavitary radiotherapy in cervix cancer patients.

    PubMed

    Huh, Seung Jae; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Eun; Kang, Min Kyu; Shin, Seong Soo; Shin, Kyung Hwan; Kim, Bokyung; Park, Won; Han, Youngyih

    2003-03-01

    To investigate the correlation between late rectal complications and rectal dose in cervix cancer patients treated with high-dose-rate intracavitary radiotherapy (HDR ICR) and to analyze factors reducing rectal complications. A total of 136 patients with cervix cancer who were treated with external beam radiotherapy (EBRT) and HDR ICR from 1995 to 1999 were retrospectively analyzed. Radiotherapy (RT) consisted of EBRT plus HDR ICR. The median EBRT dose was 50.4 Gy, and midline block was done after 30-50 Gy of EBRT. A total of six fractions of HDR ICR with 4 Gy fraction size each were applied twice per week to the A point. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. In vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 26 months (range 6-60 months). A total of 16 patients (12%) experienced rectal bleeding, which occurred 4-33 months (median 11 months) after the completion of RT. The calculated rectal doses did not differ in patients with rectal bleeding and those without, but the measured rectal doses were higher in affected patients. The differences of the measured ICR fractional rectal dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose exceeded 16 Gy, the ratio of the measured rectal dose to A point dose was > 70%; when the measured rectal BED exceeded 110 Gy(3), a high possibility of late rectal complications could be found. In vivo dosimetry using TLD during HDR ICR was a good predictor of late rectal complications. Hence, if data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.

  5. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    PubMed

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (< 2 mg/L)--high alkalinity water. Other water samples with higher TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  6. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.

    PubMed

    Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M

    2010-12-01

    The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p < 0.001) mainly owing to the significantly higher CT-related cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p < 0.001). Overall, CT accounted for 86% of the total cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwai, P; Lins, L Nadler

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT ormore » IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.« less

  8. Costs and outcomes associated with IVF using recombinant FSH.

    PubMed

    Ledger, W; Wiebinga, C; Anderson, P; Irwin, D; Holman, A; Lloyd, A

    2009-09-01

    Cost and outcome estimates based on clinical trial data may not reflect usual clinical practice, yet they are often used to inform service provision and budget decisions. To expand understanding of assisted reproduction treatment in clinical practice, an economic evaluation of IVF/intracytoplasmic sperm injection (ICSI) data from a single assisted conception unit (ACU) in England was performed. A total of 1418 IVF/ICSI cycles undertaken there between October 2001 and January 2006 in 1001 women were analysed. The overall live birth rate was 22% (95% CI: 19.7-24.2), with the 30- to 34-year age group achieving the highest rate (28%). The average recombinant FSH (rFSH) dose/cycle prescribed was 1855 IU. Average cost of rFSH/cycle was 646 pound(SD: 219 pound), and average total cost/cycle was 2932 pound (SD: 422 pound). Economic data based on clinical trials informing current UK guidance assumes higher doses of rFSH dose/cycle (1750-2625 IU), higher average cost of drugs/cycle (1179 pound), and higher average total cost/cycle (3266 pound). While the outcomes in this study matched UK averages, total cost/cycle was lower than those cited in UK guidelines. Utilizing the protocols and (lower) rFSH dosages reported in this study may enable other ACU to provide a greater number of IVF/ICSI cycles to patients within given budgets.

  9. Controlled-release systemic delivery - a new concept in cancer chemoprevention

    PubMed Central

    2012-01-01

    Many chemopreventive agents have encountered bioavailability issues in pre-clinical/clinical studies despite high oral doses. We report here a new concept utilizing polycaprolactone implants embedded with test compounds to obtain controlled systemic delivery, circumventing oral bioavailability issues and reducing the total administered dose. Compounds were released from the implants in vitro dose dependently and for long durations (months), which correlated with in vivo release. Polymeric implants of curcumin significantly inhibited tissue DNA adducts following the treatment of rats with benzo[a]pyrene, with the total administered dose being substantially lower than typical oral doses. A comparison of bioavailability of curcumin given by implants showed significantly higher levels of curcumin in the plasma, liver and brain 30 days after treatment compared with the dietary route. Withaferin A implants resulted in a nearly 60% inhibition of lung cancer A549 cell xenografts, but no inhibition occurred when the same total dose was administered intraperitoneally. More than 15 phytochemicals have been tested successfully by this formulation. Together, our data indicate that this novel implant-delivery system circumvents oral bioavailability issues, provides continuous delivery for long durations and lowers the total administered dose, eliciting both chemopreventive/chemotherapeutic activities. This would also allow the assessment of activity of minor constituents and synthetic metabolites, which otherwise remain uninvestigated in vivo. PMID:22696595

  10. Estimation of immunization providers' activities cost, medication cost, and immunization dose errors cost in Iraq.

    PubMed

    Al-lela, Omer Qutaiba B; Bahari, Mohd Baidi; Al-abbassi, Mustafa G; Salih, Muhannad R M; Basher, Amena Y

    2012-06-06

    The immunization status of children is improved by interventions that increase community demand for compulsory and non-compulsory vaccines, one of the most important interventions related to immunization providers. The aim of this study is to evaluate the activities of immunization providers in terms of activities time and cost, to calculate the immunization doses cost, and to determine the immunization dose errors cost. Time-motion and cost analysis study design was used. Five public health clinics in Mosul-Iraq participated in the study. Fifty (50) vaccine doses were required to estimate activities time and cost. Micro-costing method was used; time and cost data were collected for each immunization-related activity performed by the clinic staff. A stopwatch was used to measure the duration of activity interactions between the parents and clinic staff. The immunization service cost was calculated by multiplying the average salary/min by activity time per minute. 528 immunization cards of Iraqi children were scanned to determine the number and the cost of immunization doses errors (extraimmunization doses and invalid doses). The average time for child registration was 6.7 min per each immunization dose, and the physician spent more than 10 min per dose. Nurses needed more than 5 min to complete child vaccination. The total cost of immunization activities was 1.67 US$ per each immunization dose. Measles vaccine (fifth dose) has a lower price (0.42 US$) than all other immunization doses. The cost of a total of 288 invalid doses was 744.55 US$ and the cost of a total of 195 extra immunization doses was 503.85 US$. The time spent on physicians' activities was longer than that spent on registrars' and nurses' activities. Physician total cost was higher than registrar cost and nurse cost. The total immunization cost will increase by about 13.3% owing to dose errors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Exposure–effect relationship of mycophenolic acid and prednisolone in adult patients with lupus nephritis

    PubMed Central

    Abd Rahman, Azrin N; Tett, Susan E; Abdul Gafor, Halim A; McWhinney, Brett C; Staatz, Christine E

    2015-01-01

    Aims The aim was to examine relationships between total and unbound mycophenolic acid (MPA) and prednisolone exposure and clinical outcomes in patients with lupus nephritis. Methods Six blood samples were drawn pre- and at 1, 2, 4, 6 and 8 h post-dose and total and unbound MPA and prednisolone pre-dose (C0), maximum concentration (Cmax) and area under the concentration–time curve (AUC) were determined using non-compartmental analysis in 25 patients. The analyses evaluated drug exposures in relation to treatment response since starting MPA and drug-related adverse events. Results Dose-normalized AUC varied 10-, 8-, 7- and 19-fold for total MPA, unbound MPA, total prednisolone and unbound prednisolone, respectively. Median values (95% CI) of total MPA AUC(0,8 h) (21.5 [15.0, 42.0] vs. 11.2 [4.8, 30.0] mg l–1 h, P= 0.048) and Cmax (11.9 [6.7, 26.3] vs. 6.1 [1.6, 9.2] mg l–1, P = 0.016) were significantly higher in responders than non-responders. Anaemia was significantly associated with higher total (37.8 [14.1, 77.5] vs. 18.5 [11.7, 32.7] mg l–1 h, P = 0.038) and unbound MPA AUC(0,12 h) (751 [214, 830] vs. 227 [151, 389] mg l–1 h, P = 0.004). Unbound prednisolone AUC(0,24 h) was significantly higher in patients with Cushingoid appearance (unbound: 1372 [1242, 1774] vs. 846 [528, 1049] nmol l–1 h, P = 0.019) than in those without. Poorer treatment response was observed in patients with lowest tertile exposure to both total MPA and prednisolone as compared with patients with middle and higher tertile exposure (17% vs. 74%, P = 0.023). Conclusions This study suggests a potential role for therapeutic drug monitoring in individualizing immunosuppressant therapy in patients with lupus nephritis. PMID:25959850

  12. Exposure-effect relationship of mycophenolic acid and prednisolone in adult patients with lupus nephritis.

    PubMed

    Abd Rahman, Azrin N; Tett, Susan E; Abdul Gafor, Halim A; McWhinney, Brett C; Staatz, Christine E

    2015-11-01

    The aim was to examine relationships between total and unbound mycophenolic acid (MPA) and prednisolone exposure and clinical outcomes in patients with lupus nephritis. Six blood samples were drawn pre- and at 1, 2, 4, 6 and 8 h post-dose and total and unbound MPA and prednisolone pre-dose (C0 ), maximum concentration (Cmax ) and area under the concentration-time curve (AUC) were determined using non-compartmental analysis in 25 patients. The analyses evaluated drug exposures in relation to treatment response since starting MPA and drug-related adverse events. Dose-normalized AUC varied 10-, 8-, 7- and 19-fold for total MPA, unbound MPA, total prednisolone and unbound prednisolone, respectively. Median values (95% CI) of total MPA AUC(0,8 h) (21.5 [15.0, 42.0] vs. 11.2 [4.8, 30.0] mg l(-1) h, P= 0.048) and Cmax (11.9 [6.7, 26.3] vs. 6.1 [1.6, 9.2] mg l(-1) , P = 0.016) were significantly higher in responders than non-responders. Anaemia was significantly associated with higher total (37.8 [14.1, 77.5] vs. 18.5 [11.7, 32.7] mg l(-1) h, P = 0.038) and unbound MPA AUC(0,12 h) (751 [214, 830] vs. 227 [151, 389] mg l(-1) h, P = 0.004). Unbound prednisolone AUC(0,24 h) was significantly higher in patients with Cushingoid appearance (unbound: 1372 [1242, 1774] vs. 846 [528, 1049] nmol l(-1) h, P = 0.019) than in those without. Poorer treatment response was observed in patients with lowest tertile exposure to both total MPA and prednisolone as compared with patients with middle and higher tertile exposure (17% vs. 74%, P = 0.023). This study suggests a potential role for therapeutic drug monitoring in individualizing immunosuppressant therapy in patients with lupus nephritis. © 2015 The British Pharmacological Society.

  13. SU-F-T-415: Differences in Lung Sparing in Deep Inspiration Breath-Hold and Free Breathing Breast Plans Calculated in Pinnacle and Monaco

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saenz, D; Stathakis, S

    Purpose: Deep inspiration breath-hold (DIBH) is used for left-sided breast radiotherapy to spare the heart and lung. The magnitude of sparing has been shown to be significant. Monte Carlo, furthermore, has the potential to calculate most accurately the dose in the heterogeneous lung medium at the interface with the lung wall. The lung dose was investigated in Monaco to determine the level of sparing relative to that calculated in Pinnacle{sup 3}. Methods: Five patients undergoing DIBH radiotherapy on an Elekta Versa HD linear accelerator in conjunction with the Catalyst C-RAD surface imaging system were planned using Phillips Pinnacle{sup 3}. Freemore » breathing plans were also created to clinically assure a benefit. Both plans were re-calculated in Monaco to determine if there were any significant differences. The mean heart dose, mean left lung, and mean total lung dose were compared in addition to the V20 for left and both lungs. Dose was calculated as dose to medium as well as dose to water with a statistical precision of 0.7%. Results: Mean lung dose was significantly different (p < 0.003) between the two calculations for both DIBH (11.6% higher in Monaco) and free breathing (14.2% higher in Monaco). V20 was also higher in Monaco (p < 0.05) for DIBH (5.7% higher) and free breathing (4.9% higher). The mean heart dose was not significantly different between the dose calculations for either DIBH or free breathing. Results were no more than 0.1% different when calculated as dose to water. Conclusion: The use of Monte Carlo can provide insight on the lung dose for both free breathing and DIBH techniques for whole breast irradiation. While the sparing (dose reductions with DIBH as compared to free breathing) is equivalent for either planning system, the lung doses themselves are higher when calculated with Monaco.« less

  14. How Does Patient Radiation Exposure Compare With Low-dose O-arm Versus Fluoroscopy for Pedicle Screw Placement in Idiopathic Scoliosis?

    PubMed

    Su, Alvin W; McIntosh, Amy L; Schueler, Beth A; Milbrandt, Todd A; Winkler, Jennifer A; Stans, Anthony A; Larson, A Noelle

    Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon's preference, and individual institution's protocol. Level III-case-control study.

  15. Rumen modulatory effect of thyme, clove and peppermint oils in vitro using buffalo rumen liquor.

    PubMed

    Roy, Debashis; Tomar, S K; Kumar, Vinod

    2015-02-01

    The present study was conducted to examine the rumen modulatory effect of thyme, clove and peppermint oils on rumen fermentation pattern in vitro using roughage based diet. Thyme, clove and peppermint oils were tested at concentration of 0, 30, 300 and 600 mg/l (ppm) of total culture fluid using in vitro gas production technique in wheat straw based diet (concentrate: Wheat straw 50:50). Different in vitro parameters e.g., total gas production, methane production, nutrient degradability, volatile fatty acid (VFA) production and ammonia nitrogen concentration were studied using buffalo rumen liquor. Thyme oil at higher dose level (600 ppm) reduced (p<0.05) total gas production, feed degradability and ammonia nitrogen (NH3-N) concentration whereas total VFA concentration was significantly lower (p>0.05) in 300 and 600 ppm dose levels. 600 ppm dose level of clove oil reduced (p<0.05) total gas production, feed degradability, total VFA and acetate to propionate ratio. Methane production was significantly reduced (p<0.05) in 300 and 600 ppm dose levels of clove and peppermint oil. Right combination of these essential oils may prove to enhance performance of animals by reducing methane production and inhibiting protein degradation in rumen.

  16. Caffeine and sleep-deprivation mediated changes in open-field behaviours, stress response and antioxidant status in mice.

    PubMed

    Onaolapo, J Olakunle; Onaolapo, Y Adejoke; Akanmu, A Moses; Olayiwola, Gbola

    2016-01-01

    Effects of daily caffeine consumption on open-field behaviours, serum corticosterone and brain antioxidant levels were investigated after six hours of total sleep-deprivation in prepubertal mice. We tested the hypothesis that daily caffeine consumption may significantly alter behaviour, stress and antioxidative response of prepubertal mice to an acute episode of total sleep-deprivation. Prepubertal Swiss mice of both sexes were assigned to two main groups of 120 each (subdivided into 6 groups of 10 each, based on sex), and administered vehicle or graded oral doses of caffeine (10, 20, 40, 80 and 120 mg/kg/day) for 14 days. On day 14, a main group was subjected to 6 h of total sleep-deprivation by 'gentle-handling'. Open-field behaviours were then assessed in both groups, after which animals were euthanized, and levels of corticosterone, superoxide dismutase and glutathione peroxidase assayed. Horizontal locomotion, rearing and grooming increased significantly, compared to control, with sleep-deprived (SD) mice showing stronger caffeine-driven responses at higher doses; and SD female mice showing sustained response to caffeine, compared to respective males. Plasma corticosterone increased with increasing doses of caffeine in both non sleep-deprived (NSD) and SD mice; although SD mice had higher corticosterone levels. Sleep-deprivation and/or higher doses of caffeine were associated with derangements in brain antioxidant levels. Repeated caffeine consumption and/or acute sleep-deprivation led to significant changes in pattern of open-field behaviour and stress/antioxidant response in mice. Responses seen in the study are probably due to modulatory effects of caffeine on the total body response to stressful stimuli.

  17. Long-term antipsychotic and benzodiazepine use and brain volume changes in schizophrenia: The Northern Finland Birth Cohort 1966 study.

    PubMed

    Huhtaniska, Sanna; Jääskeläinen, Erika; Heikka, Tuomas; Moilanen, Jani S; Lehtiniemi, Heli; Tohka, Jussi; Manjón, José V; Coupé, Pierrick; Björnholm, Lassi; Koponen, Hannu; Veijola, Juha; Isohanni, Matti; Kiviniemi, Vesa; Murray, Graham K; Miettunen, Jouko

    2017-08-30

    High doses of antipsychotics have been associated with loss in cortical and total gray matter in schizophrenia. However, previous imaging studies have not taken benzodiazepine use into account, in spite of evidence suggesting adverse effects such as cognitive impairment and increased mortality. In this Northern Finland Birth Cohort 1966 study, 69 controls and 38 individuals with schizophrenia underwent brain MRI at the ages of 34 and 43 years. At baseline, the average illness duration was over 10 years. Brain structures were delineated using an automated volumetry system, volBrain, and medication data on cumulative antipsychotic and benzodiazepine doses were collected using medical records and interviews. We used linear regression with intracranial volume and sex as covariates; illness severity was also taken into account. Though both medication doses associated to volumetric changes in subcortical structures, after adjusting for each other and the average PANSS total score, higher scan-interval antipsychotic dose associated only to volume increase in lateral ventricles and higher benzodiazepine dose associated with volume decrease in the caudate nucleus. To our knowledge, there are no previous studies reporting associations between benzodiazepine dose and brain structural changes. Further studies should focus on how these observations correspond to cognition and functioning. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  18. A Novel ω-3 Acid Ethyl Ester Formulation Incorporating Advanced Lipid TechnologiesTM (ALT®) Improves Docosahexaenoic Acid and Eicosapentaenoic Acid Bioavailability Compared with Lovaza®.

    PubMed

    Lopez-Toledano, Miguel A; Thorsteinsson, Thorsteinn; Daak, Ahmed; Maki, Kevin C; Johns, Colleen; Rabinowicz, Adrian L; Sancilio, Frederick D

    2017-03-01

    The US Food and Drug Administration has approved several highly purified ω-3 fatty acid prescription drugs for the treatment of severe hypertriglyceridemia. These differ in the amounts and forms of docosahexaenoic acid (DHA) and/or eicosapentaenoic acid (EPA). This study compared the bioavailability of SC401 (1530 mg EPA-ethyl esters [EEs] and DHA-EEs plus Advanced Lipid Technologies ⁎ [ALT † ], a proprietary lipid-delivery platform to improve absorption), with. Lovaza ‡ (3600 mg ω-3, primarily EPA-EEs and DHA-EEs) under low-fat feeding conditions. This was a Phase I, randomized, open-label, single-dose, 2-way crossover study in healthy participants housed from day -3 to day 2 in each treatment period. Blood samples for pharmacokinetic measurements were collected before and after dosing, and safety profile and tolerability were assessed. In unadjusted analyses, SC401 had 5% lower C max and approximately the same AUC 0-last of EPA + DHA total lipids compared with Lovaza. When adjusted for baseline, SC401 had ~6% higher C max and 18% higher AUC 0-last for EPA + DHA total lipids, and dose- and baseline-adjusted analyses found that SC401 had ~149% higher C max and 178% higher AUC 0-last than Lovaza for EPA + DHA total lipids. The T max was also substantially longer with Lovaza (~10 hours) than with SC401 (~6 hours). These results indicate that SC401, an ω-3 acid EE formulation containing ALT † achieved high bioavailability of EPA and DHA, at a lower dose (1530 mg) than Lovaza (3600 mg), under low-fat feeding conditions. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  19. A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao Rui; Bernard, Damian; Turian, Julius

    2012-04-15

    Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lungmore » dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.« less

  20. Evaluation of total-dose iron sucrose infusions in patients with iron deficiency anemia.

    PubMed

    Wall, Geoffrey C; Pauly, Rebecca A

    2008-01-15

    The safety and efficacy of a total-dose iron sucrose infusion protocol used in a large, tertiary care teaching hospital were studied. Nondialysis-dependent patients ages 18 years or older who received > or =250 mg of iron sucrose as a single i.v. infusion between January 2005 and January 2007 were eligible for study inclusion. The protocol for total-dose iron sucrose infusion was the same for all patients. The total dose of iron sucrose for each patient was calculated using an equation that included the desired hemoglobin (Hb) value, observed Hb level, ideal body weight, and sex. The calculated dose was divided into portions, rounded to the nearest 250 mg, and administered over four hours every other day. Outcomes measured included Hb, transferrin saturation, and serum ferritin values. A total of 26 patients met the inclusion criteria. The mean +/- S.D. Hb concentration before total-dose iron sucrose infusion was 9.37 +/- 0.9 g/dL, and the mean +/- S.D. corpuscular volume was 75 +/- 7.1 mum(3). The mean +/- S.D. postinfusion Hb concentration for 19 patients for whom follow-up Hb levels were available was 11.4 +/- 1.2 g/dL, significantly higher than the 9.45 +/- 0.8 g/dL measured before the first infusion (p = 0.03). No significant adverse effects were reported in 47 of 49 infusions, with 2 patients experiencing mild nausea. A treatment protocol consisting of alternate-day total-dose iron sucrose infusions was well tolerated and appeared to be effective in improving Hb concentrations in patients with iron deficiency anemia and without chronic kidney disease.

  1. Lung Size and the Risk of Radiation Pneumonitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briere, Tina Marie, E-mail: tmbriere@mdanderson.org; Krafft, Shane; Liao, Zhongxing

    2016-02-01

    Purpose: The purpose of this study was to identify patient populations treated for non-small cell lung cancer (NSCLC) who may be more at risk of radiation pneumonitis. Methods and Materials: A total of 579 patients receiving fractionated 3D conformal or intensity modulated radiation therapy (IMRT) for NSCLC were included in the study. Statistical analysis was performed to search for cohorts of patients with higher incidences of radiation pneumonitis. In addition to conventional risk factors, total and spared lung volumes were analyzed. The Lyman-Kutcher-Burman (LKB) and cure models were then used to fit the incidence of radiation pneumonitis as a functionmore » of lung dose and other factors. Results: Total lung volumes with a sparing of less than 1854 cc at 40 Gy were associated with a significantly higher incidence of radiation pneumonitis at 6 months (38% vs 12% for patients with larger volumes, P<.001). This patient cohort was overwhelmingly female and represented 22% of the total female population of patients and nearly 30% of the cases of radiation pneumonitis. An LKB fit to normal tissue complication probability (NTCP) including volume as a dose modifying factor resulted in a dose that results in a 50% probability of complication for the smaller spared volume cohort that was 9 Gy lower than the fit to all mean lung dose data and improved the ability to predict radiation pneumonitis (P<.001). Using an effective dose parameter of n=0.42 instead of mean lung dose further improved the LKB fit. Fits to the data using the cure model produced similar results. Conclusions: Spared lung volume should be considered when treating NSCLC patients. Separate dose constraints based on smaller spared lung volume should be considered. Smaller spared lung volume patients should be followed closely for signs of radiation pneumonitis.« less

  2. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction.

    PubMed

    Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M

    2017-05-01

    To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI vol : 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose 4 level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose 4 in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose 4 in the CT imaging of a THA phantom.

  3. Comparison of two dosing schedules for subcutaneous injections of low-dose anti-CD20 veltuzumab in relapsed immune thrombocytopenia

    PubMed Central

    Liebman, Howard A.; Saleh, Mansoor N.; Bussel, James B.; Negrea, O. George; Horne, Heather; Wegener, William A.; Goldenberg, David M.

    2016-01-01

    We compared two dosing schedules for subcutaneous injections of a low-dose humanized anti-CD20 antibody, veltuzumab, in immune thrombocytopenia. Fifty adults with primary immune thrombocytopenia, in whom one or more lines of standard therapy had failed and who had a platelet count <30×109/L but no major bleeding, initially received escalating 80, 160, or 320 mg doses of subcutaneous veltuzumab administered twice, 2 weeks apart; the last group received once-weekly doses of 320 mg for 4 weeks. In all dose groups, injection reactions were transient and mild to moderate; there were no other safety issues. Forty-seven response-evaluable patients had 23 (49%) objective responses (platelet counts ≥30×109/L and ≥2 × baseline) including 15 (32%) complete responses (platelets ≥100×109/L). Responses (including complete responses) and bleeding reduction occurred in all dose groups and were not dose-dependent. In contrast, response duration increased progressively with total dose, reaching a median of 2.7 years with the four once-weekly 320-mg doses. Among nine responders retreated at relapse, three at higher dose levels responded again, including one patient who was retreated four times. In all dose groups, B-cell depletion occurred after the first dose until recovery starting 12 to 16 weeks after treatment. Veltuzumab serum levels increased with dose group according to total dose administered, but terminal half-life and clearance were comparable. Human anti-veltuzumab antibody titers developed without apparent dose dependence in nine patients, of whom six responded including five who had complete responses. Subcutaneous veltuzumab was convenient, well-tolerated, and active, without causing significant safety concerns. Platelet responses and bleeding reduction occurred in all dose groups, and response durability appeared to improve with higher doses. Clinicaltrials.gov identifier: NCT00547066 PMID:27515248

  4. Red marrow and blood dosimetry in 131I treatment of metastatic thyroid carcinoma: pre-treatment versus in-therapy results

    NASA Astrophysics Data System (ADS)

    Giostra, A.; Richetta, E.; Pasquino, M.; Miranti, A.; Cutaia, C.; Brusasco, G.; Pellerito, R. E.; Stasi, M.

    2016-06-01

    Treatment with radioiodine is a standard procedure for patients with well-differentiated thyroid cancer, but the main approach to the therapy is still empiric, consisting of the administration of fixed activities. A predictive individualized dosimetric study may represent an important tool for physicians to determine the best activity to prescribe. The aim of this work is to compare red marrow and blood absorbed dose values obtained in the pre-treatment (PT) dosimetry phase with those obtained in the in-treatment (IT) dosimetry phase in order to estimate the predictive power of PT trial doses and to determine if they can be used as a decision-making tool to safely administer higher 131I activity to potentially increase the efficacy of treatment. The PT and IT dosimetry for 50 patients has been evaluated using three different dosimetric approaches. In all three approaches blood and red marrow doses, are calculated as the sum of two components, the dose from 131I activity in the blood and the dose from 131I activity located in the remainder of the body (i.e. the blood and whole-body contributions to the total dose). PT and IT dose values to blood and red marrow appear to be well correlated irrespective of the dosimetric approach used. Linear regression analyses of PT and IT total doses, for blood and red marrow, and the whole-body contribution to these doses, showed consistent best fit slope and correlation coefficient values of approximately 0.9 and 0.6, respectively: analyses of the blood dose contribution to the total doses also yielded similar values for the best fit slope but with correlation coefficient values of approximately 0.4 reflecting the greater variance in these dose estimates. These findings suggest that pre-treatment red marrow dose assessments may represent an important tool to personalize metastatic thyroid cancer treatment, removing the constraints of a fixed activity approach and permitting potentially more effective higher 131I activities to be safely used in-treatment.

  5. Agmatine attenuates methamphetamine-induced hyperlocomotion and stereotyped behavior in mice.

    PubMed

    Kitanaka, Nobue; Kitanaka, Junichi; Hall, F Scott; Uhl, George R; Watabe, Kaname; Kubo, Hitoshi; Takahashi, Hitoshi; Tanaka, Koh-ichi; Nishiyama, Nobuyoshi; Takemura, Motohiko

    2014-04-01

    We investigated whether pretreatment with the neurotransmitter/neuromodulator agmatine (decarboxylated L-arginine) affected methamphetamine (METH)-induced hyperlocomotion and stereotypy in male ICR mice. Agmatine pretreatment alone had no effects on locomotion or stereotypy, but it produced a dose-dependent attenuation of locomotion and the total incidence of stereotyped behavior induced by a low dose of METH (5 mg/kg). The stereotypy induced by this dose was predominantly characterized by stereotyped sniffing. By contrast, agmatine did not affect the total incidence of stereotypy induced by a higher dose of METH (10 mg/kg). However, the nature of stereotypy induced by this dose of METH was substantially altered; agmatine pretreatment significantly reduced stereotyped biting but significantly increased stereotyped sniffing and persistent locomotion. Agmatine pretreatment therefore appears to produce a rightward shift in the dose-response curve for METH. Pretreatment of mice with piperazine-1-carboxamidine (a putative agmatinase inhibitor) had no effect on locomotion or stereotypy induced by a low dose of METH, suggesting that endogenous agmatine may not regulate the METH action.

  6. Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial.

    PubMed

    Pireau, Nathalie; Cordemans, Virginie; Banse, Xavier; Irda, Nadia; Lichtherte, Sébastien; Kaminski, Ludovic

    2017-11-01

    Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable). A prospective randomized trial was conducted in the hybrid operating room between December 2015 and December 2016, including 50 patients operated on for posterior instrumented thoracic and/or lumbar spinal fusion. Patients were randomized to intraoperative 3D acquisition high-dose (standard dose) or low-dose protocol, and a total of 216 pedicle screws were analyzed in terms of screw position. Two different methods were used to measure ionizing radiation: the total skin dose (derived from the dose-area product) and the radiation dose evaluated by thermoluminescent dosimeters on the surgical field. According to Gertzbein and Heary classifications, low-dose protocol provided a significant higher accuracy of pedicle screw placement than the high-dose protocol (96.1 versus 92%, respectively). Seven screws (3.2%), all implanted with the high-dose protocol, needed to be revised intraoperatively. The use of low-dose acquisition protocols reduced patient exposure by a factor of five. This study emphasizes the paramount importance of using low-dose protocols for intraoperative cone beam CT imaging coupled with the navigation system, as it at least does not affect the accuracy of pedicle screw placement and irradiates drastically less.

  7. Hydrocortisone Therapy in Catecholamine-Resistant Pediatric Septic Shock: A Pragmatic Analysis of Clinician Practice and Association With Outcomes.

    PubMed

    Nichols, Blake; Kubis, Sherri; Hewlett, Jennifer; Yehya, Nadir; Srinivasan, Vijay

    2017-09-01

    The 2012 Surviving Sepsis Campaign pediatric guidelines recommend stress dose hydrocortisone in children experiencing catecholamine-dependent septic shock with suspected or proven absolute adrenal insufficiency. We evaluated whether stress dose hydrocortisone therapy in children with catecholamine dependent septic shock correlated with random serum total cortisol levels and was associated with improved outcomes. Retrospective cohort study. Non-cardiac PICU. Critically ill children (1 mo to 18 yr) admitted between January 1, 2013, and December 31, 2013, with catecholamine dependent septic shock who had random serum total cortisol levels measured prior to potential stress dose hydrocortisone therapy. None. The cohort was dichotomized to random serum total cortisol less than 18 mcg/dL and greater than or equal to 18 mcg/dL. Associations of stress dose hydrocortisone with outcomes: PICU mortality, PICU and hospital length of stay, ventilator-free days, and vasopressor-free days were examined. Seventy children with catecholamine-dependent septic shock and measured random serum total cortisol levels were eligible (16% PICU mortality). Although 43% (30/70) had random serum total cortisol less than 18 μg/dL, 60% (42/70) received stress dose hydrocortisone. Children with random serum total cortisol less than 18 μg/dL had lower severity of illness and lower Vasopressor Inotrope Scores than those with random serum total cortisol greater than or equal to 18 μg/dL (all p < 0.05). Children with stress dose hydrocortisone had higher severity of illness and PICU mortality than those without stress dose hydrocortisone (all p < 0.05). Mean random serum total cortisol levels were similar in children with and without stress dose hydrocortisone (21.1 vs 18.7 μg/dL; p = 0.69). In children with random serum total cortisol less than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU and hospital length of stay and fewer ventilator-free days (all p < 0.05). In children with random serum total cortisol greater than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU mortality and fewer ventilator-free days and vasopressor-free days (all p < 0.05). Stress dose hydrocortisone therapy in children with catecholamine-dependent septic shock correlated more with severity of illness than random serum total cortisol levels and was associated with worse outcomes, irrespective of random serum total cortisol levels.

  8. Keeping an eye on the ring: COMS plaque loading optimization for improved dose conformity and homogeneity.

    PubMed

    Gagne, Nolan L; Cutright, Daniel R; Rivard, Mark J

    2012-09-01

    To improve tumor dose conformity and homogeneity for COMS plaque brachytherapy by investigating the dosimetric effects of varying component source ring radionuclides and source strengths. The MCNP5 Monte Carlo (MC) radiation transport code was used to simulate plaque heterogeneity-corrected dose distributions for individually-activated source rings of 14, 16 and 18 mm diameter COMS plaques, populated with (103)Pd, (125)I and (131)Cs sources. Ellipsoidal tumors were contoured for each plaque size and MATLAB programming was developed to generate tumor dose distributions for all possible ring weighting and radionuclide permutations for a given plaque size and source strength resolution, assuming a 75 Gy apical prescription dose. These dose distributions were analyzed for conformity and homogeneity and compared to reference dose distributions from uniformly-loaded (125)I plaques. The most conformal and homogeneous dose distributions were reproduced within a reference eye environment to assess organ-at-risk (OAR) doses in the Pinnacle(3) treatment planning system (TPS). The gamma-index analysis method was used to quantitatively compare MC and TPS-generated dose distributions. Concentrating > 97% of the total source strength in a single or pair of central (103)Pd seeds produced the most conformal dose distributions, with tumor basal doses a factor of 2-3 higher and OAR doses a factor of 2-3 lower than those of corresponding uniformly-loaded (125)I plaques. Concentrating 82-86% of the total source strength in peripherally-loaded (131)Cs seeds produced the most homogeneous dose distributions, with tumor basal doses 17-25% lower and OAR doses typically 20% higher than those of corresponding uniformly-loaded (125)I plaques. Gamma-index analysis found > 99% agreement between MC and TPS dose distributions. A method was developed to select intra-plaque ring radionuclide compositions and source strengths to deliver more conformal and homogeneous tumor dose distributions than uniformly-loaded (125)I plaques. This method may support coordinated investigations of an appropriate clinical target for eye plaque brachytherapy.

  9. Decorporation Approach after Rat Lung Contamination with Plutonium: Evaluation of the Key Parameters Influencing the Efficacy of a Protracted Chelation Treatment.

    PubMed

    Grémy, Olivier; Coudert, Sylvie; Renault, Daniel; Miccoli, Laurent

    2017-11-01

    While the efficacy of a protracted zinc (Zn)- or calcium (Ca)-diethylenetriaminepentaacetic acid (DTPA) treatment in reducing transuranic body burden has already been demonstrated, questions about therapeutic variables remain. In response to this, we designed animal experiments primarily to assess both the effect of fractionation of a given dose and the effect of the frequency of dose fraction, with the same total dose. In our study, rats were contaminated intravenously with plutonium (Pu) then treated several days later with Ca-DTPA given at once or in various split-dose regimens cumulating to the same total dose and spread over several days. Similar efficacies were induced by the injection of the total dose or by splitting the dose in several smaller doses, independent of the number of doses and the dose level per injection. In a second study, rats were pulmonary contaminated, and three weeks later they received a Ca-DTPA dose 11-fold higher than the maximal daily recommended dose, administered either as a single bolus or as numerous multiple injections cumulating to the same dose, based on different injection frequency schedules. Independent of frequency schedule, the various split-dose regimens spread over weeks/months were as efficient as single delivery of the total dose in mobilizing lung plutonium, and had a therapeutic advantage for removal of retained hepatic and bone plutonium burdens. We concluded that cumulative dose level was a therapeutic variable of greater importance than the distribution of split doses for the success of a repeated treatment regimen on retained tissue plutonium. In addition, pulmonary administration of clodronate, which aims at killing alveolar macrophages and subsequently releasing their plutonium content, and which is associated with a continuous Ca-DTPA infusion regimen, suggested that the efficacy of injected Ca-DTPA in decorporating lung deposit is limited, due to its restricted penetration into alveolar macrophages and not because plutonium, as a physicochemical form, is unavailable for chelation.

  10. Comparison of 2 doses of recombinant human thyrotropin for thyroid function testing in healthy and suspected hypothyroid dogs.

    PubMed

    Boretti, F S; Sieber-Ruckstuhl, N S; Wenger-Riggenbach, B; Gerber, B; Lutz, H; Hofmann-Lehmann, R; Reusch, C E

    2009-01-01

    Various protocols using different doses of recombinant human thyrotropin (rhTSH) in TSH stimulation testing have been described. However, the influence of TSH dosage on thyroxine (T4) concentration has not yet been evaluated in suspected hypothyroid dogs. To evaluate the effectiveness of 2 doses of rhTSH. Fifteen dogs with clinical signs consistent with hypothyroidism and abnormal stimulation results with 75 microg rhTSH and 18 clinically healthy dogs. All dogs were stimulated with 75 and 150 microg rhTSH IV in a 1st and 2nd stimulation test, respectively. Blood samples were taken before and 6 hours after rhTSH administration for determination of total T4 concentration. Using the higher dose led to a normal test interpretation in 9 of the 15 dogs, in which stimulation had been abnormal using the lower dose. Based on follow-up information, hypothyroidism was excluded in 7 of these 9 dogs. In all 6 dogs with a blunted response to the higher dose, hypothyroidism could be confirmed. Healthy dogs showed significantly higher post-TSH T4 concentrations with the higher compared with the lower dose. Post-TSH T4 concentrations after TSH stimulation were not related to dogs' body weight in either healthy or diseased dogs. TSH dose significantly influenced test interpretation in suspected hypothyroid dogs. Differentiation between primary hypothyroidism and nonthyroidal disease was improved with 150 microg rhTSH. Because this effect was independent of the dogs' body weight, the higher dose is recommended in dogs that have concurrent disease or are receiving medication.

  11. 131I-tositumomab myeloablative radioimmunotherapy for non-Hodgkin’s lymphoma: radiation dose to the testes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hattori, Naoya; Gopal, Ajay K.; Shields, Andrew T.

    Purpose: To investigate radiation doses to the testes delivered by a radiolabeled anti-CD20 antibody and its effects on male sex hormone levels. Materials and methods: Testicular uptake and retention of 131I-tositumomab were measured, and testicular absorbed doses were calculated for 67 male patients (54+/-11 years of age) with non-Hodgkin's lymphoma who had undergone myeloablative radioimmunotherapy (RIT) using 131I-tositumomab. Time-activity curves for the major organs, testes, and whole body were generated from planar imaging studies. In a subset of patients, male sex hormones were measured before and 1 year after the therapy. Results: The absorbed dose to the testes showed considerablemore » variability (range=4.4-70.2 Gy). Pretherapy levels of total testosterone were below the lower limit of the reference range, and post-therapy evaluation demonstrated further reduction [4.6+/-1.8 nmol/l (pre-RIT) vs. 3.8+/-2.9 nmol/l (post-RIT), P<0.05]. Patients receiving higher radiation doses to the testes (>=25 Gy) showed a greater reduction [4.7+/-1.6 nmol/l (pre-RIT) vs. 3.3+/-2.7 nmol/l (post-RIT), P<0.05] compared with patients receiving lower doses (<25 Gy), who showed no significant change in total testosterone levels. Conclusion: The testicular radiation absorbed dose varied highly among individual patients. Finally, patients receiving higher doses to the testes were more likely to show post-RIT suppression of testosterone levels.« less

  12. Use of tomotherapy in treatment of synchronous bilateral breast cancer: dosimetric comparison study

    PubMed Central

    Wadasadawala, T; Sarin, R; Upreti, R R; Paul, S; Phurailatpam, R

    2015-01-01

    Objective: Synchronous malignancy in both breasts is a rare incidence. The present study aims at dosimetric comparison of conventional bitangential radiotherapy (RT) technique with conventional [field-in-field (FIF)] and rotational [Helical TomoTherapy® and TomoDirect™ (TD); Accuray Inc., Sunnyvale, CA] intensity-modulated RT for patients with synchronous bilateral breast cancer (SBBC). Methods: CT data sets of 10 patients with SBBC were selected for the present study. RT was planned for all patients on both sides to whole breast and/or chest wall using the above-mentioned techniques. Six females with breast conservation on at least one side also had a composite plan along with tumour bed (TB) boost using sequential electrons for bitangential and FIF techniques or sequential helical tomotherapy (HT) boost (for TD) or simultaneous integrated boost (SIB) for HT. Results: All techniques produced acceptable target coverage. The hotspot was significantly lower with FIF technique and HT but higher with TD. For the organs at risk doses, HT resulted in significant reduction of the higher dose volumes. Similarly, TD resulted in significant reduction of the mean dose to the heart and total lung by reducing the lower dose volumes. All techniques of delivering boost to the TB were comparable in terms of target coverage. HT-SIB markedly reduced mean doses to the total lung and heart by specifically lowering the higher dose volumes. Conclusion: This study demonstrates the cardiac and pulmonary sparing ability of tomotherapy in the setting of SBBC. Advances in knowledge: This is the first study demonstrating feasibility of treatment of SBBC using tomotherapy. PMID:25605345

  13. Effect of amphetamine on human macronutrient intake.

    PubMed

    Foltin, R W; Kelly, T H; Fischman, M W

    1995-11-01

    Six male subjects participated in a 15-day residential study examining the effects of amphetamine on macronutrient intake. During the first 11 days, carbohydrate intake was manipulated by providing lunch meals high (155 g) or low (25 g) in carbohydrate. Subjects received oral d-amphetamine (5, 10 mg/70 kg, BID) or placebo. Total daily caloric intake was similar under both lunch conditions (approximately 3400/Kcal), but carbohydrate contributed more energy under the high-carbohydrate condition. Both doses of amphetamine decreased total caloric intake to approximately 2600 Kcal, by decreasing the number of eating bouts, without affecting macronutrient selection. During the last four days subjects received a higher daily dose of amphetamine (30 mg/70 kg in four doses) or placebo, and were allowed to self-select lunch. Although 30 mg amphetamine decreased intake of all macronutrients, the relative contribution of carbohydrate to total caloric intake was increased from 54% to 62%, while the contribution of fat was decreased from 32% to 26% and the contribution of protein was decreased from 14% to 12%. Thus, at a high dose, amphetamine altered the relative contribution of specific macronutrients to total caloric intake.

  14. Passive dosimetry aboard the Mir Orbital Station: internal measurements.

    PubMed

    Benton, E R; Benton, E V; Frank, A L

    2002-10-01

    Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

  15. Volumetric tumor burden and its effect on brachial plexus dosimetry in head and neck intensity-modulated radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romesser, Paul B.; Qureshi, Muhammad M.; Kovalchuk, Nataliya

    2014-07-01

    To determine the effect of gross tumor volume of the primary (GTV-P) and nodal (GTV-N) disease on planned radiation dose to the brachial plexus (BP) in head and neck intensity-modulated radiotherapy (IMRT). Overall, 75 patients underwent definitive IMRT to a median total dose of 69.96 Gy in 33 fractions. The right BP and left BP were prospectively contoured as separate organs at risk. The GTV was related to BP dose using the unpaired t-test. Receiver operating characteristics curves were constructed to determine optimized volumetric thresholds of GTV-P and GTV-N corresponding to a maximum BP dose cutoff of > 66 Gy.more » Multivariate analyses were performed to account for factors associated with a higher maximal BP dose. A higher maximum BP dose (> 66 vs ≤ 66 Gy) correlated with a greater mean GTV-P (79.5 vs 30.8 cc; p = 0.001) and ipsilateral GTV-N (60.6 vs 19.8 cc; p = 0.014). When dichotomized by the optimized nodal volume, patients with an ipsilateral GTV-N ≥ 4.9 vs < 4.9 cc had a significant difference in maximum BP dose (64.2 vs 59.4 Gy; p = 0.001). Multivariate analysis confirmed that an ipsilateral GTV-N ≥ 4.9 cc was an independent predictor for the BP to receive a maximal dose of > 66 Gy when adjusted individually for BP volume, GTV-P, the use of a low anterior neck field technique, total planned radiation dose, and tumor category. Although both the primary and the nodal tumor volumes affected the BP maximal dose, the ipsilateral nodal tumor volume (GTV-N ≥ 4.9 cc) was an independent predictor for high maximal BP dose constraints in head and neck IMRT.« less

  16. Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: Phase I study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGarry, Ronald C.; Papiez, Lech; Williams, Mark

    Purpose: A Phase I dose escalation study of stereotactic body radiation therapy to assess toxicity and local control rates for patients with medically inoperable Stage I lung cancer. Methods and Materials: All patients had non-small-cell lung carcinoma, Stage T1a or T1b N0, M0. Patients were immobilized in a stereotactic body frame and treated in escalating doses of radiotherapy beginning at 24 Gy total (3 x 8 Gy fractions) using 7-10 beams. Cohorts were dose escalated by 6.0 Gy total with appropriate observation periods. Results: The maximum tolerated dose was not achieved in the T1 stratum (maximum dose = 60 Gy),more » but within the T2 stratum, the maximum tolerated dose was realized at 72 Gy for tumors larger than 5 cm. Dose-limiting toxicity included predominantly bronchitis, pericardial effusion, hypoxia, and pneumonitis. Local failure occurred in 4/19 T1 and 6/28 T2 patients. Nine local failures occurred at doses {<=}16 Gy and only 1 at higher doses. Local failures occurred between 3 and 31 months from treatment. Within the T1 group, 5 patients had distant or regional recurrence as an isolated event, whereas 3 patients had both distant and regional recurrence. Within the T2 group, 2 patients had solitary regional recurrences, and the 4 patients who failed distantly also failed regionally. Conclusions: Stereotactic body radiation therapy seems to be a safe, effective means of treating early-stage lung cancer in medically inoperable patients. Excellent local control was achieved at higher dose cohorts with apparent dose-limiting toxicities in patients with larger tumors.« less

  17. Estimated fluoride doses from toothpastes should be based on total soluble fluoride.

    PubMed

    Oliveira, Maria José L; Martins, Carolina C; Paiva, Saul M; Tenuta, Livia M A; Cury, Jaime A

    2013-11-01

    The fluoride dose ingested by young children may be overestimated if based on levels of total fluoride (TF) rather than levels of bioavailable fluoride (total soluble fluoride-TSF) in toothpaste. The aim of the present study was to compare doses of fluoride intake based on TF and TSF. Fluoride intake in 158 Brazilian children aged three and four years was determined after tooth brushing with their usual toothpaste (either family toothpaste (n = 80) or children's toothpaste (n = 78)). The estimated dose (mg F/day/Kg of body weight) of TF or TSF ingested was calculated from the chemical analysis of the toothpastes. Although the ingested dose of TF from the family toothpastes was higher than that from the children's toothpastes (0.074 ± 0.007 and 0.039 ± 0.003 mg F/day/Kg, respectively; p < 0.05), no difference between types of toothpaste was found regarding the ingested dose based on TSF (0.039 ± 0.005 and 0.039 ± 0.005 mg F/day/Kg, respectively; p > 0.05). The fluoride dose ingested by children from toothpastes may be overestimated if based on the TF of the product. This finding suggests that the ingested dose should be calculated based on TSF. Dose of TSF ingested by children is similar whether family or children's toothpaste is used.

  18. Estimated Fluoride Doses from Toothpastes Should be Based on Total Soluble Fluoride

    PubMed Central

    Oliveira, Maria José L.; Martins, Carolina C.; Paiva, Saul M.; Tenuta, Livia M. A.; Cury, Jaime A.

    2013-01-01

    The fluoride dose ingested by young children may be overestimated if based on levels of total fluoride (TF) rather than levels of bioavailable fluoride (total soluble fluoride—TSF) in toothpaste. The aim of the present study was to compare doses of fluoride intake based on TF and TSF. Fluoride intake in 158 Brazilian children aged three and four years was determined after tooth brushing with their usual toothpaste (either family toothpaste (n = 80) or children’s toothpaste (n = 78)). The estimated dose (mg F/day/Kg of body weight) of TF or TSF ingested was calculated from the chemical analysis of the toothpastes. Although the ingested dose of TF from the family toothpastes was higher than that from the children’s toothpastes (0.074 ± 0.007 and 0.039 ± 0.003 mg F/day/Kg, respectively; p < 0.05), no difference between types of toothpaste was found regarding the ingested dose based on TSF (0.039 ± 0.005 and 0.039 ± 0.005 mg F/day/Kg, respectively; p > 0.05). The fluoride dose ingested by children from toothpastes may be overestimated if based on the TF of the product. This finding suggests that the ingested dose should be calculated based on TSF. Dose of TSF ingested by children is similar whether family or children’s toothpaste is used. PMID:24189183

  19. beta- and gamma-Comparative dose estimates on Enewetak Atoll.

    PubMed

    Crase, K W; Gudiksen, P H; Robison, W L

    1982-05-01

    Enewetak Atoll is one of the Pacific atolls used for atmospheric testing of U.S. nuclear weapons. Beta dose and gamma-ray exposure measurements were made on two islands of the Enewetak Atoll during July-August 1976 to determine the beta and low energy gamma-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a beta-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to beta- or low energy gamma-contribution. The contribution at any particular site, however, is somewhat dependent on ground cover, since a minimal amount of vegetation will reduce it significantly from that over bare soil, but thick stands of vegetation have little effect on any further reductions. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey (En73). Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the beta's or low energy gamma's, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  20. Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas.

    PubMed

    Farzin, Mostafa; Molls, Michael; Astner, Sabrina; Rondak, Ina-Christine; Oechsner, Markus

    2015-12-01

    In 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (VMAT): simultaneous integrated boost (SIB) vs. sequential boost (SEB). The investigation focused on the analysis of dose distributions in the target volumes and the organs at risk (OARs). After contouring the target volumes [planning target volumes (PTVs) and boost volumes (BVs)] and OARs, SIB planning and SEB planning were performed. The SEB method consisted of two plans: in the first plan the PTV received 50 Gy in 25 fractions with a 2-Gy dose per fraction. In the second plan the BV received 10 Gy in 5 fractions with a dose per fraction of 2 Gy. The doses of both plans were summed up to show the total doses delivered. In the SIB method the PTV received 54 Gy in 30 fractions with a dose per fraction of 1.8 Gy, while the BV received 60 Gy in the same fraction number but with a dose per fraction of 2 Gy. All of the OARs showed higher doses (Dmax and Dmean) in the SEB method when compared with the SIB technique. The differences between the two methods were statistically significant in almost all of the OARs. Analysing the total doses of the target volumes we found dose distributions with similar homogeneities and comparable total doses. Our analysis shows that the SIB method offers advantages over the SEB method in terms of sparing OARs.

  1. Comparative trial of low- and high-dose zonisamide as monotherapy for childhood epilepsy.

    PubMed

    Eun, So-Hee; Kim, Heung Dong; Eun, Baik-Lin; Lee, In Kyu; Chung, Hee Jung; Kim, Joon Sik; Kang, Hoon-Chul; Lee, Young-Mock; Suh, Eun Sook; Kim, Dong Wook; Eom, Soyong; Lee, Joon Soo; Moon, Han Ku

    2011-09-01

    To evaluate the effectiveness of zonisamide (ZNS) as monotherapy in children with newly diagnosed epilepsy. This randomized, multicenter trial included a 2-4-week titration and a 24-week maintenance phase after randomization to low-(3-4 mg/kg/day) or high-(6-8 mg/kg/day) dose groups as target maintenance dosages. The primary outcome measure was the seizure-free rate over 6 months, while a secondary measure was the change in cognition and behavior from screening to the end of the maintenance phase. Out of 125 patients enrolled, 90 (49 low-dose and 41 high-dose) completed the study. Forty-one patients (63.1%) in the low-dose group and 34(57.6%) in the high-dose group achieved 6 months' freedom from seizures (p=0.66). After treatment, the picture arrangement subtest improved in the low-dose group (p=0.047) while the vocabulary subtest worsened in the high-dose group (p=0.020). Comparing between the two groups, the vocabulary subtest in the high-dose group was significantly worse than that in the low-dose group (p=0.002). Social competence, somatic complaints, depression/anxiety and delinquent and aggressive behavior in the low-dose group were significantly improved (p<0.05). Moreover, total social competence, somatic complaints, delinquent behavior, externalizing, and total behavior problems were significantly more improved in the low-dose group than the high-dose group (p<0.05). ZNS is an effective monotherapy for newly diagnosed childhood epilepsy. Lower doses of ZNS have a similar efficacy and more beneficial neurocognitive effects compared to higher doses. When prescribing higher doses of ZNS, one must be aware of the possible manifestation of problems associated with language development, such as those affecting vocabulary acquisition. Copyright © 2011 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  2. Control of natural microorganisms in chamomile (Chamomilla recutita L.) by gamma ray and electron beam irradiation.

    PubMed

    Al-Bachir, Mahfouz

    2017-01-01

    Microbial contamination levels and corresponding sensitivities to gamma rays (GR) and elec- tron beam (EB) irradiation were tested in chamomile (Chamomile recutta L.). Chamomile powders were treated with 10 and 20 kGy by GR and EB, respectively. Microbiological and chemical analyses were performed on controls and treated samples immediately after irradiation, and after 12 months of storage. The control samples of chamomile exhibited rather high microbiological contamination, exceeding the levels of 4 log10 CFU g-1   (CFU - colony forming units) reported by national and international authorities as the maximum permissible total count level. Irradiation with GR and EB was found to cause a reduction in microbial contamination proportionate to the dose delivered. The sterilizing effect of EB on microorganisms was higher than the GR one. A dose of 10 kGy of GR and EB significantly (p < 0.05) reduced the total bacte- rial, total coliform and total fungal contamination. A dose of 20 kGy of GR significantly (p < 0.05) reduced the total bacterial and total fungal contamination, while a 20 kGy dose of EB reduced the initial bacterial, total coliform and total fungal contamination to below detection level when the analysis was carried out im- mediately after irradiation treatment or after 12 months of storage. The comparative study demonstrated that electron beam was more effective for decontamination of chamomile powder than gamma irradiation.

  3. Chemical Dosimeter Tube With Coaxial Sensing Rod

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E.

    1993-01-01

    Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.

  4. Flavonoids and Tannins from Smilax china L. Rhizome Induce Apoptosis Via Mitochondrial Pathway and MDM2-p53 Signaling in Human Lung Adenocarcinoma Cells.

    PubMed

    Fu, San; Yang, Yanfang; Liu, Dan; Luo, Yan; Ye, Xiaochuan; Liu, Yanwen; Chen, Xin; Wang, Song; Wu, Hezhen; Wang, Yuhang; Hu, Qiwei; You, Pengtao

    2017-01-01

    In vitro evidence indicates that Smilax china L. rhizome (SCR) can inhibit cell proliferation. Therefore, in the present study, we analyzed the effects in vitro of SCR extracts on human lung adenocarcinoma A549 cells. Our results showed that A549 cell growth was inhibited in a dose- and time-dependent manner after treatment with SCR extracts. Total flavonoids and total tannins from SCR induced A549 apoptosis in a dose-dependent manner, as shown by our flow cytometry analysis, which was consistent with the alterations in nuclear morphology we observed. In addition, the total apoptotic rate induced by total tannins was higher than the rate induced by total flavonoids at the same dose. Cleaved-caspase-3 protein levels in A549 cells after treatment with total flavonoids or total tannins were increased in a dose-dependent manner, followed by the activation of caspase-8 and caspase-9, finally triggering to PARP cleavage. Furthermore, total flavonoids and total tannins increased the expression of Bax, decreased the expression of Bcl-2, and promoted cytochrome [Formula: see text] release. Moreover, MDM2 and p-MDM2 proteins were decreased, while p53 and p-p53 proteins were increased, both in a dose-dependent manner, after A549 treatment with total flavonoids and total tannins. Finally, cleaved-caspase-3 protein levels in the total flavonoids or total tannins-treated H1299 (p53 null) and p53-knockdown A549 cells were increased. Our results indicated that total flavonoids and total tannins from SCR exerted a remarkable effect in reducing A549 growth through their action on mitochondrial pathway and disruption of MDM2-p53 balance. Hence, our findings demonstrated a potential application of total flavonoids and total tannins from SCR in the treatment of human lung adenocarcinoma.

  5. Effect of Direct-Fed Microbial Dosage on the Fecal Concentrations of Enterohemorrhagic Escherichia coli in Feedlot Cattle.

    PubMed

    Luedtke, Brandon E; Bosilevac, Joseph M; Harhay, Dayna M; Arthur, Terrance M

    2016-04-01

    Contamination of beef products by Shiga toxin-producing Escherichia coli is a concern for food safety with a particular subset, the enterohemorrhagic E. coli (EHEC), being the most relevant to human disease. To mitigate food safety risks, preharvest intervention strategies have been implemented with the aim to reduce EHEC in cattle. One class of interventions that has been widely used in feedlots is direct-fed microbials (DFMs), which can contain various dosing rates of probiotic bacteria. Here we compare the use of two different doses of a commercially available DFM on total EHEC load in a commercial feedlot setting. The DFMs used were the standard 10(9) Propionibacterium freudenreichii and 10(6) Lactobacillus acidophilus colony forming units (CFUs)/head/day dose of Bovamine(®) (Nutrition Physiology Company, Guymon, OK) and the higher dose, Bovamine Defend™ (Nutrition Physiology Company), which is dosed at 10(9) P. freudenreichii and 10(9) Lactobacillus acidophilus CFUs/head/day. To analyze the total EHEC fecal concentration, 2200 head of cattle were assigned a DFM feed regimen lasting approximately 5 months. At harvest, 480 head of cattle were sampled using rectoanal mucosal swabs. A quantitative polymerase chain reaction assay targeting ecf1 was used to enumerate the total EHEC fecal concentration for 240 head fed the low-dose DFM and 240 head fed the high-dose DFM. No significant difference (p > 0.05) in the fecal concentration of total EHEC was observed between the two doses. This suggests that using an increased dosage provides no additional reduction in the total EHEC fecal concentration of feedlot cattle compared to the standard dosage.

  6. Induction prednisone dosing for childhood nephrotic syndrome: how low should we go?

    PubMed

    Sibley, Matthew; Roshan, Abishek; Alshami, Alanoud; Catapang, Marisa; Jöbsis, Jasper J; Kwok, Trevor; Polderman, Nonnie; Sibley, Jennifer; Matsell, Douglas G; Mammen, Cherry

    2018-05-22

    Historically, children with nephrotic syndrome (NS) across British Columbia (BC), Canada have been cared for without formal standardization of induction prednisone dosing. We hypothesized that local historical practice variation in induction dosing was wide and that children treated with lower doses had worse relapsing outcomes. This retrospective cohort study included 92 NS patients from BC Children's Hospital (1990-2010). We excluded secondary causes of NS, age < 1 year at diagnosis, steroid resistance, and incomplete induction due to early relapse. We explored cumulative induction dose and defined dosing quartiles. Relapsing outcomes above and below each quartile threshold were compared including total relapses in 2 years, time to first relapse, and proportions developing frequently relapsing NS (FRNS) or starting a steroid-sparing agent (SSA). Cumulative prednisone was widely distributed with approximated median, 1st, and 3rd quartile doses of 2500, 2000, and 3000 mg/m 2 respectively. Doses ≤ 2000 mg/m 2 showed significantly higher relapses (4.2 vs 2.7), shorter time to first relapse (61 vs 175 days), and higher SSA use (36 vs 14%) compared to higher doses. Doses ≤ 2500 mg/m 2 also showed significantly more relapses (3.9 vs 2.2), quicker first relapse (79 vs 208 days), and higher FRNS (37 vs 17%) and SSA use (28 vs 11%). Relapsing outcomes lacked statistical difference in ≤ 3000 vs > 3000 mg/m 2 doses. Results strongly justify our development of a standardized, province-wide NS clinical pathway to reduce practice variation and minimize under-treatment. The lowest induction prednisone dosing threshold to minimize future relapsing risks is likely between 2000 and 2500 mg/m 2 . Further prospective studies are warranted.

  7. Efficacy of dosing and re-dosing of two oral fixed combinations of indomethacin, prochlorperazine and caffeine compared with oral sumatriptan in the acute treatment of multiple migraine attacks: a double-blind, double-dummy, randomised, parallel group, multicentre study

    PubMed Central

    Sandrini, G; Cerbo, R; Del Bene, E; Ferrari, A; Genco, S; Grazioli, I; Martelletti, P; Nappi, G; Pinessi, L; Sarchielli, P; Tamburro, P; Uslenghi, C; Zanchin, G

    2007-01-01

    Aims and methods: In this double-blind, double-dummy, randomised, parallel group, multicentre study, the efficacy of dosing and re-dosing of a fixed combination of indomethacin, prochlorperazine and caffeine (Indoprocaf) was compared with encapsulated sumatriptan in the acute treatment of two migraine attacks. Additionally, in the group taking Indoprocaf, two different oral formulations were tested: effervescent tablets and encapsulated coated tablets. Results: Of 297 patients randomised (150 assigned to Indoprocaf and 147 to sumatriptan), 281 were included in the intention-to-treat efficacy analysis. The initial dosing of Indoprocaf and sumatriptan was similarly effective with pain-free rates higher than 30% (95% CI of odds-ratio: 0.57–1.28) and headache relief rates of about 60% (95% CI of odds-ratio: 0.82–1.84) with both the drugs. The efficacy of re-dosing of Indoprocaf as rescue medication was more effective than that of sumatriptan with pain-free values of 47% vs. 27% in the total attacks with a statistically significant difference in the first migraine attack in favour of Indoprocaf. The efficacy of re-dosing to treat a recurrence/relapse was very high without differences between the drugs (pain-free: 60% with Indoprocaf and 50% with sumatriptan in the total attacks). Indoprocaf and sumatriptan were well-tolerated. Conclusion: The study demonstrated that the efficacy of the initial dosing of Indoprocaf was not higher than that of sumatriptan, but that the strategy to use the lowest effective dose as soon as the headache occurred, followed by a second dose if the headache has not relieved or to treat a relapse, was very effective, especially with Indoprocaf. PMID:17627707

  8. Radiological impact of airborne effluents of coal and nuclear plants.

    PubMed

    McBride, J P; Moore, R E; Witherspoon, J P; Blanco, R E

    1978-12-08

    Radiation doses from airborne effluents of model coal-fired and nuclear power plants (1000 megawatts electric) are compared. Assuming a 1 percent ash release to the atmosphere (Environmental Protection Agency regulation) and 1 part per million of uranium and 2 parts per million of thorium in the coal (approximately the U.S. average), population doses from the coal plant are typically higher than those from pressurized-water or boiling-water reactors that meet government regulations. Higher radionuclide contents and ash releases are common and would result in increased doses from the coal plant. The study does not assess the impact of non-radiological pollutants or the total radiological impacts of a coal versus a nuclear economy.

  9. Effects of isoflavone supplements vs. soy foods on blood concentrations of genistein and daidzein in adults

    PubMed Central

    Gardner, Christopher D.; Chatterjee, Lorraine M.; Franke, Adrian A.

    2012-01-01

    The objective of this investigation was to examine the pharmacokinetics of isoflavone concentrations over a 24-hour period among healthy adults consuming either soy foods or soy isoflavone tablets at different doses. This randomized, cross-over trial was conducted with twelve generally healthy adults. The three phases of the intervention included: isoflavone tablets at 1) 144 mg/day or 2) 288 mg/day, and 3) soy foods designed to provide a calculated 96 mg isoflavones/day (doses in aglycone equivalents). Doses were spread out over three meals/day. After 6 days on each study phase, plasma isoflavone concentrations were determined on the seventh day at 0, 4, 8, 10, 12 and 24 hours. Average levels of total isoflavone concentrations at 8, 10 and 12 hours were >4 μmol/L for the soy food phase and for the higher dose tablet phase. Genistein concentrations were higher overall in the soy food vs. both the lower and the higher dose supplement phases of the study (p≤0.05). When comparing plasma concentrations for the two doses of tablets, saturation appeared more evident for genistein than daidzein at the higher dose level. In conclusion, we observed important differences in the pharmacokinetics of genistein and daidzein contrasting the sources and doses of isoflavones when administered three times daily, including a possible advantage for increasing serum concentrations of isoflavones from consuming soy foods relative to isoflavone supplements. PMID:18602820

  10. Effects of isoflavone supplements vs. soy foods on blood concentrations of genistein and daidzein in adults.

    PubMed

    Gardner, Christopher D; Chatterjee, Lorraine M; Franke, Adrian A

    2009-03-01

    The objective of this investigation was to examine the pharmacokinetics of isoflavone concentrations over a 24-h period among healthy adults consuming either soy foods or soy isoflavone tablets at different doses. This randomized, cross-over trial was conducted with 12 generally healthy adults. The three phases of the intervention included isoflavone tablets at (1) 144 mg/day or (2) 288 mg/day and (3) soy foods designed to provide a calculated 96 mg isoflavones/day (doses in aglycone equivalents). Doses were spread out over three meals per day. After 6 days on each study phase, plasma isoflavone concentrations were determined on the seventh day at 0, 4, 8, 10, 12 and 24 h. Average levels of total isoflavone concentrations at 8, 10 and 12 h were >4 micromol/L for the soy food phase and for the higher dose tablet phase. Genistein concentrations were higher overall in the soy food vs. both the lower and the higher dose supplement phases of the study (P<.05). When comparing plasma concentrations for the two doses of tablets, saturation appeared more evident for genistein than for daidzein at the higher dose level. In conclusion, we observed important differences in the pharmacokinetics of genistein and daidzein contrasting the sources and doses of isoflavones when administered three times daily, including a possible advantage for increasing serum concentrations of isoflavones from consuming soy foods relative to isoflavone supplements.

  11. Concomitant use of FSH and low-dose recombinant hCG during the late follicular phase versus conventional controlled ovarian stimulation for intracytoplasmic sperm injection cycles.

    PubMed

    Iaconelli, Carla Andrade Rebello; Setti, Amanda Souza; Braga, Daniela Paes Almeida Ferreira; Maldonado, Luiz Guilherme Louzada; Iaconelli, Assumpto; Borges, Edson; Aoki, Tsutomu

    2017-12-01

    The objective of this study was to investigate the effects of low-dose hCG supplementation on ICSI outcomes and controlled ovarian stimulation (COS) cost. Three hundred and thirty patients undergoing ICSI were split into groups according to the COS protocol: (i) control group (n = 178), including patients undergoing conventional COS treatment; and (ii) low-dose hCG group (n = 152), including patients undergoing COS with low-dose hCG supplementation. Lower mean total doses of FSH administered and higher mean oestradiol level and mature oocyte rates were observed in the low-dose hCG group. A significantly higher fertilization rate, high-quality embryo rate and blastocyst formation rate were observed in the low-dose hCG group as compared to the control group. The miscarriage rate was significantly higher in the control group compared to the low-dose hCG group. A significantly lower incidence of OHSS was observed in the low-dose hCG group. There was also a significantly lower gonadotropin cost in the low-dose hCG group as compared to the control group ($1235.0 ± 239.0×$1763.0 ± 405.3, p < 0.001). The concomitant use of low-dose hCG and FSH results in a lower abortion rate and increased number of mature oocytes retrieved, as well as improved oocyte quality, embryo quality and blastocyst formation and reduced FSH requirements.

  12. Stereotactic body radiotherapy for stage I non-small-cell lung cancer using higher doses for larger tumors: results of the second study.

    PubMed

    Miyakawa, Akifumi; Shibamoto, Yuta; Baba, Fumiya; Manabe, Yoshihiko; Murai, Taro; Sugie, Chikao; Yanagi, Takeshi; Takaoka, Taiki

    2017-09-11

    Efficacy of stereotactic body radiotherapy (SBRT) in stage I non-small-cell lung cancer (NSCLC) has almost been established. In Japan, the protocol of 48 Gy in 4 fractions over 4 days has been most often employed, but higher doses may be necessary to control large tumors. Previously, we conducted a clinical study using SBRT for stage I NSCLC employing different doses depending on tumor diameter, which was closed in 2008. Thereafter, a new study employing higher doses has been conducted, which is reported here. The purpose of this study was to review the safety and effectiveness of the higher doses. We escalated the total dose for the improvement of local control for large tumors. In this study, 71 patients underwent SBRT between December 2008 and April 2014. Isocenter doses of 48, 50, and 52 Gy were administered for tumors with a longest diameter of < 1.5 cm, 1.5-3 cm, and > 3 cm, respectively. It was recommended to cover 95% of the PTV with at least 90% of the isocenter dose, and in all but one cases, 95% of the PTV received at least 80% of the prescribed dose. Treatments were delivered in 4 fractions, giving 2 fractions per week. SBRT was performed with 6-MV photons using 4 non-coplanar and 3 coplanar beams. The median follow-up period was 44 months for all patients and 61 months for living patients. Overall survival (OS) was 65%, progression-free survival (PFS) was 55%, and cumulative incidence of local recurrence (LR) was 15% at 5 years. The 5-year OS was 69% for 57 stage IA patients and 53% for 14 stage IB patients (p = 0.44). The 5-year PFS was 55 and 54%, respectively (p = 0.98). The 5-year cumulative incidence of LR was 11 and 31%, respectively (p = 0.09). The cumulative incidence of Grade ≥ 2 radiation pneumonitis was 25%. Our newer SBRT study yielded reasonable local control and overall survival and acceptable toxicity, but escalating the total dose did not lead to improved outcomes. UMIN000027231 , registered on 3 May 2017. Retrospectively registered.

  13. Dedicated dental volumetric and total body multislice computed tomography: a comparison of image quality and radiation dose

    NASA Astrophysics Data System (ADS)

    Strocchi, Sabina; Colli, Vittoria; Novario, Raffaele; Carrafiello, Gianpaolo; Giorgianni, Andrea; Macchi, Aldo; Fugazzola, Carlo; Conte, Leopoldo

    2007-03-01

    Aim of this work is to compare the performances of a Xoran Technologies i-CAT Cone Beam CT for dental applications with those of a standard total body multislice CT (Toshiba Aquilion 64 multislice) used for dental examinations. Image quality and doses to patients have been compared for the three main i-CAT protocols, the Toshiba standard protocol and a Toshiba modified protocol. Images of two phantoms have been acquired: a standard CT quality control phantom and an Alderson Rando ® anthropomorphic phantom. Image noise, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and geometric accuracy have been considered. Clinical image quality was assessed. Effective dose and doses to main head and neck organs were evaluated by means of thermo-luminescent dosimeters (TLD-100) placed in the anthropomorphic phantom. A Quality Index (QI), defined as the ratio of squared CNR to effective dose, has been evaluated. The evaluated effective doses range from 0.06 mSv (i-CAT 10 s protocol) to 2.37 mSv (Toshiba standard protocol). The Toshiba modified protocol (halved tube current, higher pitch value) imparts lower effective dose (0.99 mSv). The conventional CT device provides lower image noise and better SNR, but clinical effectiveness similar to that of dedicated dental CT (comparable CNR and clinical judgment). Consequently, QI values are much higher for this second CT scanner. No geometric distortion has been observed with both devices. As a conclusion, dental volumetric CT supplies adequate image quality to clinical purposes, at doses that are really lower than those imparted by a conventional CT device.

  14. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  15. Analysis of Radiation Effects in Digital Subtraction Angiography of Intracranial Artery Stenosis.

    PubMed

    Guo, Chaoqun; Shi, Xiaolei; Ding, Xianhui; Zhou, Zhiming

    2018-04-21

    Intracranial artery stenosis (IAS) is the most common cause for acute cerebral accidents. Digital subtraction angiography (DSA) is the gold standard to detect IAS and usually brings excess radiation exposure to examinees and examiners. The artery pathology might influence the interventional procedure, causing prolonged radiation effects. However, no studies on the association between IAS pathology and operational parameters are available. A retrospective analysis was conducted on 93 patients with first-ever stroke/transient ischemic attack, who received DSA examination within 3 months from onset in this single center. Comparison of baseline characteristics was determined by 2-tailed Student's t-test or the chi-square test between subjects with and without IAS. A binary logistic regression analysis was performed to determine the association between IAS pathology and the items with a P value <0.05 in Student's t-test or chi-square test. There were 93 candidates (42 with IAS and 51 without IAS) in this study. The 2 groups shared no significance of the baseline characteristics (P > 0.05). We found a significantly higher total time, higher kerma area product, greater total dose, and greater DSA dose in the IAS group than in those without IAS (P < 0.05). A binary logistic regression analysis indicated the significant association between total time and IAS pathology (P < 0.05) but no significance in kerma area product, radiation dose, and DSA dose (P > 0.05). IAS pathology would indicate a prolonged total time of DSA procedure in clinical practice. However, the radiation effects would not change with pathologic changes. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Relationship between high daily erythemal UV doses, total ozone, surface albedo and cloudiness: An analysis of 30 years of data from Switzerland and Austria

    NASA Astrophysics Data System (ADS)

    Rieder, H. E.; Staehelin, J.; Weihs, P.; Vuilleumier, L.; Maeder, J. A.; Holawe, F.; Blumthaler, M.; Lindfors, A.; Peter, T.; Simic, S.; Spichtinger, P.; Wagner, J. E.; Walker, D.; Ribatet, M.

    2010-10-01

    This work investigates the occurrence frequency of days with high erythemal UV doses at three stations in Switzerland and Austria (Davos, Hoher Sonnblick and Vienna) for the time period 1974-2003. While several earlier studies have reported on increases in erythemal UV dose up to 10% during the last decades, this study focuses on days with high erythemal UV dose, which is defined as a daily dose at least 15% higher than for 1950s clear-sky conditions (which represent preindustrial conditions with respect to anthropogenic chlorine). Furthermore, the influence of low column ozone, clear-sky/partly cloudy conditions and surface albedo on UV irradiance has been analyzed on annual and seasonal basis. The results of this study show that in the Central Alpine Region the number of days with high UV dose increased strongly in the early 1990s. A large fraction of all days with high UV dose occurring in the period 1974-2003 was found especially during the years 1994-2003, namely 40% at Davos, 54% at Hoher Sonnblick and 65% at Vienna. The importance of total ozone, clear-sky/partly cloudy conditions and surface albedo (e.g. in dependence of snow cover) varies strongly among the seasons. However, overall the interplay of low total ozone and clear-sky/partly cloudy conditions led to the largest fraction of days showing high erythemal UV dose. Furthermore, an analysis of the synoptic weather situation showed that days with high erythemal UV dose, low total ozone and high relative sunshine duration occur at all three stations more frequently during situations with low pressure gradients or southerly advection.

  17. Methadone and Metabolites in Hair of Methadone-Assisted Pregnant Women and Their Infants

    PubMed Central

    Himes, Sarah K; Goodwin, Robert S; Rock, Colleen M; Jones, Hendrée E; Johnson, Rolley E; Wilkins, Diana G; Huestis, Marilyn A

    2012-01-01

    Methadone is the recommended pharmacotherapy for opioid-dependent pregnant women. The primary aims of this study were to determine whether a dose-concentration relationship exists between cumulative maternal methadone dose, methadone and metabolite concentrations in maternal hair during pregnancy and whether maternal hair methadone and metabolite concentrations predict neonatal outcomes. Materials and Methods Hair specimens were collected monthly from opioid-dependent mothers enrolled in methadone treatment and 4 of their infants. Hair specimens were segmented (3cm), washed (maternal hair only) and analyzed for methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenylpyrroline (EMDP) by liquid chromatography tandem mass spectrometry. Results There was large inter-subject variability and no dose-concentration relationship for cumulative methadone dose and methadone, EDDP, EMDP or total concentrations in hair. For individual women, a positive trend was noted for cumulative methadone dose and methadone and EDDP concentrations in hair. There was a positive linear trend for cumulative methadone dose and EDDP/methadone ratio in maternal hair, perhaps reflecting methadone’s induction of its own metabolism. Maternal methadone concentrations were higher than those in infant hair, and infant EDDP hair concentrations were higher than those in maternal hair. Maternal methadone dose, and methadone and EDDP hair concentrations were not correlated with peak infant neonatal abstinence syndrome (NAS) scores, days to peak NAS, duration of NAS, time to NAS onset, birth length, head circumference or amount of neonatal morphine pharmacotherapy. Maternal cumulative 3rd trimester methadone dose was positively correlated with infant birth weight. Conclusion Methadone and EDDP in pregnant women’s hair are markers of methadone exposure and do not predict total methadone dose, nor neonatal outcomes from in utero methadone exposure. PMID:22495425

  18. Irradiation doses on thyroid gland during the postoperative irradiation for breast cancer.

    PubMed

    Akın, Mustafa; Ergen, Arzu; Unal, Aysegul; Bese, Nuran

    2014-01-01

    Thyroid gland is one of the radiosensitive endocrine organs in the body. It has been shown that direct irradiation of thyroid with total doses of 26 to 30 Gy can lead to functional abnormalities. In this study, irradiation doses on thyroid gland of the patients who received postoperative chest-wall/breast and regional nodal irradiation were assessed. Retrospective analyses of treatment plans from 122 breast cancer patients who were treated with 3D conformal radiotherapy (3D CRT) planning was performed. All patients received irradiation to supraclavicular/level III lymph nodes in addition to chest-wall/breast. A total dose of 46 Gy was delivered in 25 days to supraclavicular/level III lymph node region while a total dose of 50 Gy was delivered to whole breast/chest-wall. Thyroid gland was contoured on 2-5 mm thickness of computed tomography scans. Absolute thyroid volume, mean thyroid doses were calculated. The mean thyroid volume of all patients was 16.7 cc (min: 1.9 cc, max: 41.6 cc). The mean irradiation dose on was 22.5 Gy (0.32 Gy-46.5 Gy). The level of dose was higher than 26 Gy in 44% of the patients. In majority of the node-positive breast cancer patients treated with 3D CRT, the thyroid gland was exposed to considerable doses. On the other hand, for 44% of the patients are at risk for developing thyroid function abnormalities which should be considered during the routine follow-up.

  19. Association of the GGCX (CAA)16/17 repeat polymorphism with higher warfarin dose requirements in African Americans.

    PubMed

    Cavallari, Larisa H; Perera, Minoli; Wadelius, Mia; Deloukas, Panos; Taube, Gelson; Patel, Shitalben R; Aquino-Michaels, Keston; Viana, Marlos A G; Shapiro, Nancy L; Nutescu, Edith A

    2012-02-01

    Little is known about genetic contributors to higher than usual warfarin dose requirements, particularly for African Americans. This study tested the hypothesis that the γ-glutamyl carboxylase (GGCX) genotype contributes to warfarin dose requirements greater than 7.5 mg/day in an African American population. A total of 338 African Americans on a stable dose of warfarin were enrolled. The GGCX rs10654848 (CAA)n, rs12714145 (G>A), and rs699664 (p.R325Q); VKORC1 c.-1639G>A and rs61162043; and CYP2C9*2, *3, *5, *8, *11, and rs7089580 genotypes were tested for their association with dose requirements greater than 7.5 mg/day alone and in the context of other variables known to influence dose variability. The GGCX rs10654848 (CAA)16 or 17 repeat occurred at a frequency of 2.6% in African Americans and was overrepresented among patients requiring greater than 7.5 mg/day versus those who required lower doses (12 vs. 3%, P=0.003; odds ratio 4.0, 95% confidence interval, 1.5-10.5). The GGCX rs10654848 genotype remained associated with high dose requirements on regression analysis including age, body size, and VKORC1 genotype. On linear regression, the GGCX rs10654848 genotype explained 2% of the overall variability in warfarin dose in African Americans. An examination of the GGCX rs10654848 genotype in warfarin-treated Caucasians revealed a (CAA)16 repeat frequency of only 0.27% (P=0.008 compared with African Americans). These data support the GGCX rs10654848 genotype as a predictor of higher than usual warfarin doses in African Americans, who have a 10-fold higher frequency of the (CAA)16/17 repeat compared with Caucasians.

  20. Higher hydrocortisone dose increases bilirubin in hypopituitary patients- results from an RCT.

    PubMed

    Werumeus Buning, Jorien; Kootstra-Ros, Jenny E; Brummelman, Pauline; van den Berg, Gerrit; van der Klauw, Melanie; Wolffenbuttel, Bruce H R; van Beek, André P; Dullaart, Robin P F

    2016-05-01

    Bilirubin has anti-oxidative and anti-inflammatory properties, which may explain its proposed protective effects on the development of cardiometabolic disorders. Glucocorticoids affect heme oxygenase regulation in vitro, which plays a key role in bilirubin production. Effects of variations in glucocorticoid exposure on circulating bilirubin levels in humans are unknown. Here we tested whether a higher hydrocortisone replacement dose affects circulating bilirubin in hypopituitary patients. A randomized double-blind cross-over study (ClinicalTrials.gov, number NCT01546992) was performed in 47 patients with secondary adrenal failure [10-week exposure to a higher hydrocortisone dose (0·4-0·6 mg/kg body weight) vs. 10 weeks of a lower hydrocortisone dose (0·2-0·3 mg/kg body weight)]. Plasma total bilirubin was increased by 10% from 7 to 8 μM in response to the higher hydrocortisone dose (P = 0·033). This effect was inversely related to age (P = 0·042), but was unaffected by sex, obesity and (replacement for) other hormonal insufficiencies. The higher hydrocortisone dose also resulted in lower alkaline phosphatase (P = 0·006) and aspartate aminotransferase activities (P = 0·001). Bilirubin is modestly increased in response to higher glucocorticoid exposure in humans, in conjunction with lower alkaline phosphatase and aspartate aminotransferase activities, which are supposed to represent biomarkers of a pro-inflammatory state and enhanced liver fat accumulation. © 2016 The Authors. European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation.

  1. 210Po in the diet at Seville (Spain) and its contribution to the dose by ingestion

    PubMed Central

    Díaz-Francés, I.; Mantero, J.; Díaz-Ruiz, J.; Manjón, G.; García-Tenorio, R.

    2016-01-01

    The activity concentrations of 210Po have been determined in a total of 24 representative diet samples from Seville (south of Spain), inferring from the obtained values the annual intakes of 210Po by ingestion of the affected population and the corresponding committed effective doses. The annual intakes of 210Po and, consequently, the corresponding doses of this radionuclide show a high variability in correspondence with the variability in the composition of the analysed samples over time, and their magnitude is comparable with the estimated ones in other regions/countries of the world with similar diet habits (countries where the marine products have a considerable weight in the diets). Committed effective doses by ingestion higher than 0.1 mSv y−1 have been estimated exclusively for 210Po, reflecting the importance of this radionuclide and this route of incorporation in the magnitude of the total doses received by the affected population from natural sources. PMID:25802464

  2. Spasmodic dysphonia: a seven-year audit of dose titration and demographics in the Indian population.

    PubMed

    Nerurkar, N K; Banu, T P

    2014-07-01

    This study aimed to evaluate the demographics of spasmodic dysphonia in the Indian population and to analyse the optimum dose titration of botulinum toxin type A in this group. A comparative analysis with international studies was also performed. The study involved a retrospective analysis and audit of botulinum toxin type A dose titration in spasmodic dysphonia patients who visited our voice clinic between January 2005 and January 2012. The average total therapeutic dose required for patients with adductor spasmodic dysphonia was 4.2 U per patient per vocal fold (total 8.4 U per patient), and for patients with abductor spasmodic dysphonia, it was 4.6 U per patient. Our audit revealed that 80 per cent of the spasmodic dysphonia patients were male, which contrasts dramatically with international studies, wherein around 80 per cent of spasmodic dysphonia patients were female. Our study also revealed a higher dose titration of botulinum toxin for the Indian spasmodic dysphonia population in both adductor and abductor spasmodic dysphonia cases.

  3. Dose reduction potential of iterative reconstruction algorithms in neck CTA-a simulation study.

    PubMed

    Ellmann, Stephan; Kammerer, Ferdinand; Allmendinger, Thomas; Brand, Michael; Janka, Rolf; Hammon, Matthias; Lell, Michael M; Uder, Michael; Kramer, Manuel

    2016-10-01

    This study aimed to determine the degree of radiation dose reduction in neck CT angiography (CTA) achievable with Sinogram-affirmed iterative reconstruction (SAFIRE) algorithms. 10 consecutive patients scheduled for neck CTA were included in this study. CTA images of the external carotid arteries either were reconstructed with filtered back projection (FBP) at full radiation dose level or underwent simulated dose reduction by proprietary reconstruction software. The dose-reduced images were reconstructed using either SAFIRE 3 or SAFIRE 5 and compared with full-dose FBP images in terms of vessel definition. 5 observers performed a total of 3000 pairwise comparisons. SAFIRE allowed substantial radiation dose reductions in neck CTA while maintaining vessel definition. The possible levels of radiation dose reduction ranged from approximately 34 to approximately 90% and depended on the SAFIRE algorithm strength and the size of the vessel of interest. In general, larger vessels permitted higher degrees of radiation dose reduction, especially with higher SAFIRE strength levels. With small vessels, the superiority of SAFIRE 5 over SAFIRE 3 was lost. Neck CTA can be performed with substantially less radiation dose when SAFIRE is applied. The exact degree of radiation dose reduction should be adapted to the clinical question, in particular to the smallest vessel needing excellent definition.

  4. Comparative occupational radiation exposure between fixed and mobile imaging systems.

    PubMed

    Kendrick, Daniel E; Miller, Claire P; Moorehead, Pamela A; Kim, Ann H; Baele, Henry R; Wong, Virginia L; Jordan, David W; Kashyap, Vikram S

    2016-01-01

    Endovascular intervention exposes surgical staff to scattered radiation, which varies according to procedure and imaging equipment. The purpose of this study was to determine differences in occupational exposure between procedures performed with fixed imaging (FI) in an endovascular suite compared with conventional mobile imaging (MI) in a standard operating room. A series of 116 endovascular cases were performed over a 4-month interval in a dedicated endovascular suite with FI and conventional operating room with MI. All cases were performed at a single institution and radiation dose was recorded using real-time dosimetry badges from Unfors RaySafe (Hopkinton, Mass). A dosimeter was mounted in each room to establish a radiation baseline. Staff dose was recorded using individual badges worn on the torso lead. Total mean air kerma (Kar; mGy, patient dose) and mean case dose (mSv, scattered radiation) were compared between rooms and across all staff positions for cases of varying complexity. Statistical analyses for all continuous variables were performed using t test and analysis of variance where appropriate. A total of 43 cases with MI and 73 cases with FI were performed by four vascular surgeons. Total mean Kar, and case dose were significantly higher with FI compared with MI. (mean ± standard error of the mean, 523 ± 49 mGy vs 98 ± 19 mGy; P < .00001; 0.77 ± 0.03 mSv vs 0.16 ± 0.08 mSv, P < .00001). Exposure for the primary surgeon and assistant was significantly higher with FI compared with MI. Mean exposure for all cases using either imaging modality, was significantly higher for the primary surgeon and assistant than for support staff (ie, nurse, radiology technologist) beyond 6 feet from the X-ray source, indicated according to one-way analysis of variance (MI: P < .00001; FI: P < .00001). Support staff exposure was negligible and did not differ between FI and MI. Room dose stratified according to case complexity (Kar) showed statistically significantly higher scattered radiation in FI vs MI across all quartiles. The scattered radiation is several-fold higher with FI than MI across all levels of case complexity. Radiation exposure decreases with distance from the radiation source, and is negligible outside of a 6-foot radius. Modern endovascular suites allow high-fidelity imaging, yet additional strategies to minimize exposure and occupational risk are needed. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Planned Two-Fraction Proton Beam Stereotactic Radiosurgery for High-Risk Inoperable Cerebral Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hattangadi, Jona A.; Chapman, Paul H.; Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA

    2012-06-01

    Purpose: To evaluate patients with high-risk cerebral arteriovenous malformations (AVMs), based on eloquent brain location or large size, who underwent planned two-fraction proton stereotactic radiosurgery (PSRS). Methods and Materials: From 1991 to 2009, 59 patients with high-risk cerebral AVMs received two-fraction PSRS. Median nidus volume was 23 cc (range, 1.4-58.1 cc), 70% of cases had nidus volume {>=}14 cc, and 34% were in critical locations (brainstem, basal ganglia). Median AVM score based on age, AVM size, and location was 3.19 (range, 0.9-6.9). Many patients had prior surgery or embolization (40%) or prior PSRS (12%). The most common prescription was 16more » Gy radiobiologic equivalent (RBE) in two fractions, prescribed to the 90% isodose. Results: At a median follow-up of 56.1 months, 9 patients (15%) had total and 20 patients (34%) had partial obliteration. Patients with total obliteration received higher total dose than those with partial or no obliteration (mean dose, 17.6 vs. 15.5 Gy (RBE), p = 0.01). Median time to total obliteration was 62 months (range, 23-109 months), and 5-year actuarial rate of partial or total obliteration was 33%. Five-year actuarial rate of hemorrhage was 22% (95% confidence interval, 12.5%-36.8%) and 14% (n = 8) suffered fatal hemorrhage. Lesions with higher AVM scores were more likely to hemorrhage (p = 0.024) and less responsive to radiation (p = 0.026). The most common complication was Grade 1 headache acutely (14%) and long term (12%). One patient developed a Grade 2 generalized seizure disorder, and two had mild neurologic deficits. Conclusions: High-risk AVMs can be safely treated with two-fraction PSRS, although total obliteration rate is low and patients remain at risk for future hemorrhage. Future studies should include higher doses or a multistaged PSRS approach for lesions more resistant to obliteration with radiation.« less

  6. In vitro effect of low-level laser on odontoblast-like cells

    NASA Astrophysics Data System (ADS)

    Oliveira, C. F.; Basso, F. G.; Lins, E. C.; Kurachi, C.; Hebling, J.; Bagnato, V. S.; de Souza Costa, C. A.

    2011-02-01

    The aim of this study was to evaluate the metabolism of odontoblast-like MDPC-23 cells subjected to direct LLL irradiation. The cells were seeded (20,000 cells/well) in 24-well plates and incubated for 24 hours at 37°C. After this period, the culture medium (DMEM) was replaced by fresh DMEM supplemented with 2 or 5% (stress induction by nutritional deficit) or 10% fetal bovine serum (FBS). The cells were exposed to laser doses of 2, 4, 10, 15 and 25 J/cm2 from a near infrared InGaAsP diode laser prototype (LASERTable; 780±3 nm, 40 mW). One control group (sham irradiation) was established for each experimental condition (laser dose x FBS supplementation). Three and 72 hours after the last irradiation, cells were analyzed with respect to metabolism, morphology, total protein expression and alkaline phosphatase (ALP) activity. Higher metabolism and total protein expression were observed 72 hours after the last irradiation at the doses of 15 and 25 J/cm2 (Mann-Whitney; p < 0.05). Higher ALP activity was obtained with 5% FBS when the cells were irradiated with doses of 2 and 10 J/cm2. For the dose of 25 J/cm2, the highest ALP activity was observed with 10% FBS. It was concluded that the LLLT parameters used in this study stimulated the metabolic activity of the MDPC-23 cells, especially at the doses of 15 and 25 J/cm2.

  7. Low-molecular-weight heparin use in the obese, elderly, and in renal insufficiency.

    PubMed

    Clark, N P

    2008-01-01

    Superior bioavailability and simple weight-based dosing have made low-molecular-weight heparins (LMWH) the preferred agents for treatment and prevention of venous thromboembolism (VTE) for most indications. Despite improved pharmacokinetics, there remain populations where appropriate LMWH dose intensity and frequency are open to question. Obese patients have a lower proportion of lean body mass as a percentage of total body weight. As a result, LMWH dosing based on total body weight could cause supra-therapeutic anticoagulation. Elderly patients also have less lean body mass in addition to a higher incidence of age-related renal disease and increased risk of bleeding. Renal insufficiency presents a risk of LMWH accumulation as well as increased risk of bleeding. Among LMWH products, only dalteparin labeling recommends a maximum dose. Prospective data call into question the validity of this dose limitation. Additionally, because obese patients are already at higher risk of VTE recurrence, they may be particularly sensitive to subtherapeutic anticoagulation. Prospective data evaluating LMWH use in elderly patients have been limited to in-patient treatment. Few recommendations can be made in this population other than close monitoring. Renal insufficiency is a risk for bleeding during LMWH use. Available evidence supports the potential for enoxaparin accumulation, but not tinzaparin. Enoxaparin dose adjustment, either empiric or based on anti-Xa monitoring, has insufficient data to support widespread implementation. Unfractionated heparin is not reliant on renal elimination and is a sensible option for VTE treatment in patients with a creatinine clearance<30 ml/min.

  8. Variability in protein binding of teicoplanin and achievement of therapeutic drug monitoring targets in critically ill patients: lessons from the DALI Study.

    PubMed

    Roberts, J A; Stove, V; De Waele, J J; Sipinkoski, B; McWhinney, B; Ungerer, J P J; Akova, M; Bassetti, M; Dimopoulos, G; Kaukonen, K-M; Koulenti, D; Martin, C; Montravers, P; Rello, J; Rhodes, A; Starr, T; Wallis, S C; Lipman, J

    2014-05-01

    The aims of this study were to describe the variability in protein binding of teicoplanin in critically ill patients as well as the number of patients achieving therapeutic target concentrations. This report is part of the multinational pharmacokinetic DALI Study. Patients were sampled on a single day, with blood samples taken both at the midpoint and the end of the dosing interval. Total and unbound teicoplanin concentrations were assayed using validated chromatographic methods. The lower therapeutic range of teicoplanin was defined as total trough concentrations from 10 to 20 mg/L and the higher range as 10-30 mg/L. Thirteen critically ill patients were available for analysis. The following are the median (interquartile range) total and free concentrations (mg/L): midpoint, total 13.6 (11.2-26.0) and free 1.5 (0.7-2.5); trough, total 11.9 (10.2-22.7) and free 1.8 (0.6-2.6). The percentage free teicoplanin for the mid-dose and trough time points was 6.9% (4.5-15.6%) and 8.2% (5.5-16.4%), respectively. The correlation between total and free antibiotic concentrations was moderate for both the midpoint (ρ = 0.79, P = 0.0021) and trough (ρ = 0.63, P = 0.027). Only 42% and 58% of patients were in the lower and higher therapeutic ranges, respectively. In conclusion, use of standard dosing for teicoplanin leads to inappropriate concentrations in a high proportion of critically ill patients. Variability in teicoplanin protein binding is very high, placing significant doubt on the validity of total concentrations for therapeutic drug monitoring in critically ill patients. Copyright © 2014 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  9. Disposition of styrene-acrylonitrile (SAN) trimer in female rats: single dose intravenous and gavage studies.

    PubMed

    Gargas, Michael L; Collins, Brad; Fennell, Timothy R; Gaudette, Norman F; Sweeney, Lisa M

    2008-04-21

    Styrene-acrylonitrile trimer (SAN Trimer), a mixture of six isomers (four isomers of 4-cyano-1,2,3,4-tetrahydro-alpha-methyl-1-naphthaleneacetonitrile [THAN] and two isomers of 4-cyano-1,2,3,4-tetrahydro-1-naphthaleneproprionitrile [THNP]), is a by-product of a specific production process of styrene-acrylonitrile polymer. Disposition studies in female rats were conducted to evaluate the pharmacokinetic behavior of [3H]SAN Trimer following a single intravenous administration (26 mg/kg) to nonpregnant rats; a single gavage administration (nominal doses of 25 mg/kg, 75 mg/kg, or 200 mg/kg in corn oil) to nonpregnant rats; and a single gavage administration (nominal dose of 200 mg/kg in corn oil) to pregnant and lactating rats. SAN Trimer was rapidly eliminated from blood (T1/2 approximately 1h) following a single intravenous dose and following single oral doses (T1/2 approximately 3-4h). SAN Trimer was also rapidly excreted in the urine and feces following single oral doses, while total radioactivity was cleared more slowly. In pregnant rats, the concentrations of both radioactivity and SAN Trimer 2h after dosing were highest in the blood, followed by the placenta, with the lowest levels in the fetus. In lactating rats, the concentrations of both radioactivity and SAN Trimer were higher in milk than in maternal blood. Total radioactivity and SAN Trimer blood concentrations in nonpregnant, pregnant, and lactating rats were both higher in lactating rats compared to nonpregnant and pregnant rats.

  10. Relationship between plant growth and cytological effect in root apical meristem after exposure of wheat dry seeds to carbon ion beams

    NASA Astrophysics Data System (ADS)

    Liu, Qingfang; Wang, Zhuanzi; Zhou, Libin; Qu, Ying; Lu, Dong; Yu, Lixia; Du, Yan; Jin, Wenjie; Li, Wenjian

    2013-06-01

    In order to analyze the relationship between plant growth and cytological effects, wheat dry seeds were exposed to various doses of 12C6+ beams and the biological endpoints reflecting plant growth and root apical meristem (RAM) activities were investigated. The results showed that most of the seeds were able to germinate normally within all dose range, while the plant survival rate descended at higher doses. The seedling growth including root length and seedling height also decreased significantly at higher doses. Mitotic index (MI) in RAM had no changes at 10 and 20 Gy and decreased obviously at higher doses and the proportion of prophase cells had the same trend with MI. These data suggested that RAM cells experienced cell cycle arrest, which should be responsible for the inhibition of root growth after exposure to higher doses irradiation. Moreover, various types of chromosome aberrations (CAs) were observed in the mitotic cells. The frequencies of mitotic cells with lagging chromosomes and these with anaphase bridges peaked around 60 Gy, while the frequencies of these with fragments increased as the irradiation doses increased up to 200 Gy. The total frequencies of mitotic cells with CAs induced by irradiation increased significantly with the increasing doses. The serious damage of mitotic chromosomes maybe caused cell cycle arrest or cell death. These findings suggested that the influences of 12C6+ beams irradiation on plant growth were related to the alternation of mitotic activities and the chromosomal damages in RAM.

  11. On the mutagenicity of methadone hydrochloride. Induced dominant lethal mutation and spermatocyte chromosomal aberrations in treated males.

    PubMed

    Badr, F M; Rabouh, S A; Badr, R S

    1979-11-01

    The mutagenicity of methadone hydrochloride was tested in male mice using the dominant lethal mutation technique and the spermatocyte test of treated mice. Male mice of C3H inbred strain received one of the following doses, 1, 2, 4 or 6 mg/kg body weight once a day for 3 consecutive days. Another group of mice served as control and received saline instead. Treated males were then mated to virgin females at 3-day intervals for a period of 45 days. Pregnant females were dissected at mid-term and the corpora lutea and intrauterine contents were recorded. The spermatocytes of treated males were examined 45-50 d after treatments with methadone and abnormal pairing configurations were scored. The methadone treatment was found to increase the rate of preimplantation deaths consistently in all post-meiotic stages with all doses used. In addition, the higher doses, 4 and 6 mg, affected spermatogonia stages. Quantitatively, the dose-response relationship cannot be demonstrated though the spectrum of effect increased with higher doses as more spermatogenesis stages became more sensitive to the treatment. In many cases the frequency of live implants showed a positive correlation with preimplantation deaths in contrast with the frequency of early deaths which showed only sporadic variation. The mutation indices based on total embryonic death indicate that methadone hydrochloride affected several stages of germ-cell maturation namely, spermatozoa (M.I. 14-35), late spermatids (M.I. 15-48), early spermatids (M.I. 14-50), late spermatocytes (M.I. 15-43) and spermatogonial stages (M.I. 12-63). Chromosome analysis at diakinesis-metaphase 1 revealed significant increase in the frequency of sex chromosome and autosome univalents with different doses of methadone. The smallest dose applied was quite effective and the data represent direct dose-response relationship. Of the multivalent configuration, the most frequent type was chain quadrivalents. The frequencies of total translocations per cell were estimated as 0.1, 0.16 and 0.2 for the 4 applied doses illustrating a dose-response relationship for the doses: 1, 2 and 4 mg, whereas with the higher dose, 6 mg, an abrupt decrease was apparent (0.05). This study calls for concern regarding the possible genetic hazards this drug may impose upon human populations.

  12. Comparison of PDR brachytherapy and external beam radiation therapy in the case of breast cancer

    NASA Astrophysics Data System (ADS)

    Teymournia, L.; Berger, D.; Kauer-Dorner, D.; Poljanc, K.; Seitz, W.; Aiginger, H.; Kirisits, C.

    2009-04-01

    Pulsed dose rate brachytherapy (PDR) was compared to external beam radiation therapy (EBRT) in the case of breast cancer. The benefits were figured out by evaluation of dosimetric parameters and calculating the normal tissue complication probability (NTCP). PDR plans were set up for five randomly chosen left-sided breast cancer patients delivering a total dose of 50.4 Gy to the target (dose rate 0.8 Gy h-1). For EBRT five left-sided breast cancer patients were planned using 3D-conformal tangential photon beams with a prescribed total dose of 50 Gy (2 Gy/fraction) to the total breast volume. For plan ranking and NTCP calculation the physical dose was first converted into the biologically effective dose (BED) and then into the normalized total dose (NTD) using the linear quadratic model with an α/β ratio of 3 Gy. In PDR the relative effectiveness (RE) was calculated for each dose bin of the differential dose volume histogram to get the BED. NTCPs were calculated for the ipsilateral lung and the heart as contoured on CT slices based on the Lyman model and the Kutcher reduction scheme. Dosimetric parameters as Vth (percentage of the total volume exceeding a threshold dose) and Jackson's fdam (fraction of the organ damaged) were also used to figure out the benefits. The comparison of calculated NTCPs in PDR and EBRT showed no difference between these two modalities. All values were below 0.01%. fdam derived from EBRT was always higher (mean value 8.95% versus 1.21% for the lung). The mean V10 and V20 of the lung related to BED were 6.32% and 1.72% for PDR versus 11.72% and 9.59% for EBRT. When using dosimetric parameters as Vth and fdam, PDR was mostly superior to EBRT in respect of sparing normal tissues. NTCP calculation as a single method of modality ranking showed a lack of information, especially when normal tissue was exposed to low radiation doses.

  13. Total skin electron irradiation for mycosis fungoides: relationship between acute toxicities and measured dose at different anatomic sites.

    PubMed

    Desai, K R; Pezner, R D; Lipsett, J A; Vora, N L; Luk, K H; Wong, J Y; Chan, S L; Findley, D O; Hill, L R; Marin, L A

    1988-09-01

    From June 1978 to June 1986, 50 patients with primary and recurrent mycosis fungoides were treated with total skin electron irradiation (TSEI), using the Stanford technique, to a total dose of 3600 cGy. TSEI was used alone, or in combination with low dose total body photon irradiation, or MOPP. Thermoluminescent dosimeter (TLD) measurements of the prescribed skin dose were obtained on twenty patients. The dorsum of the foot was 24% higher. The axillae, the bottom, and the arch of the foot were significantly underdosed. Frequencies of acute toxicities noted at 2000 cGy were: Skin, Grade I-II (RTOG) 80%. Partial epilation: scalp, 100%; eyebrows and at eyelashes, 20%. Nail dystrophy, 48%. Edema: hands and feet, 44%. Bullae: dorsum of feet, 8%; hands, 4%; and 3600 cGy: Skin, grade III 22%. Total epilation: scalp, 66%; eyebrows and eyelashes, 56%. Nail loss, 38%. Edema: hands and feet, 76%. Bullae: dorsum of feet, 34%; hands, 12%. Conjunctivitis, 4%. Large bullae, were more significant on the dorsum of the feet. Severe moist desquamation occurred in eight patients who had ulcerated lesions on initial presentation. Three patients were hospitalized due to ulceration and skin infection. All patients completed treatment after a short to moderate break. No patient developed skin necrosis, or corneal ulceration. No correlation exists between dose level, degree and onset of toxicity with previous chemotherapy or TBI. We conclude that the overall toxicity of TSEI is well tolerated.

  14. Effects of Low Dose Metformin in Adolescents with Type I Diabetes Mellitus: A Randomized, Double-Blinded Placebo-Controlled Study

    PubMed Central

    Nadeau, Kristen; Chow, Kelsey; Alam, Lyla; Lindquist, Kara; Cambell, Sarah; McFann, Kim; Klingensmith, Georgeanna; Walravens, Phillipe

    2014-01-01

    Background Insulin resistance increases during adolescence in those with type 1 diabetes (T1DM), complicating glycemic control and potentially increasing cardiovascular disease (CVD) risk. Metformin, typically used in type 2 diabetes (T2DM), is a possible adjunct therapy in T1DM to help improve glycemic control and insulin sensitivity. Objective We hypothesized that metformin would improve metabolic parameters in adolescents with T1DM. Design, Setting, and Participants This randomized, double-blinded, placebo-controlled trial included 74 pubertal adolescents (ages 13–20 years) with T1DM. Participants were randomized to receive either metformin or placebo for six months. HbA1c, insulin dose, waist circumference, BMI, and blood pressure were measured at baseline, 3 and 6 months, with fasting lipids measured at baseline and 6 months. Results Total daily insulin dose, BMI Z-score and waist circumference significantly decreased at 3 and 6 months compared to baseline within the metformin group, even among normal-weight participants. In placebo group, total insulin dose and systolic blood pressure increased significantly at 3 months and total insulin dose increased significantly at 6 months. No significant change was observed in HbA1c at any time point between metformin and placebo groups or within either group. Conclusions Low-dose metformin likely improves BMI as well as insulin sensitivity in T1DM adolescents, as indicated by a decrease in total daily insulin dose. The decrease in waist circumference indicates that fat distribution is also likely impacted by metformin in T1DM. Further studies with higher metformin doses and more detailed measurements are needed to confirm these results, their underlying mechanisms, and potential impact on CVD in T1DM youth. PMID:24698216

  15. A prospective randomized study of the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in hyperthyroidism.

    PubMed

    Pusuwan, Pawana; Tuntawiroon, Malulee; Sritongkul, Nopamol; Chaudakshetrin, Pachee; Nopmaneejumruslers, Cherdchai; Komoltri, Chulalak; Thepamongkhol, Kullathorn; Khiewvan, Benjapa; Tuchinda, Pongpija; Sriussadaporn, Sutin

    2011-03-01

    To compare the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in patients with hyperthyroidism. One hundred fifty patients with proven hyperthyroidism were randomly allocated into the high (74 patients) and low (76 patients) dose regimen of I-131 treatment. Four patients of the high dose group and one patient of the low dose group were excluded because of lost follow-up. A gland-specific dosage was calculated on the estimated weight of thyroid gland and 24-hour I-131 uptake. The high and low I-131 dose regimens were 150 microCi/gm and 100 microCi/gm, respectively. The first mean radioiodine activity administered to the high and low dose group was 10.2 and 8 mCi, respectively. Repeated treatment was given to 25 patients of the high dose group and 40 patients of the low dose group. Clinical outcome and calculated costs for outpatient attendances, and laboratory tests together with initial and subsequent treatments were evaluated for one year after I-131 treatment. Elimination of hyperthyroidism that resulted in either euthyroidism or hypothyroidism was classified as therapeutic success. The cost effectiveness was also compared. At 6 months after treatment, 45 (64.3%) patients receiving high dose and 59 (78.7%) patients receiving low dose were hyperthyroidism. Clinical outcome at one year showed persistence of hyperthyroidism in 21 (30%) patients of the high dose regimen and 36 (48%) patients of the low dose regimen. At one year post treatment, it was demonstrated that the high dose regimen could eliminate hyperthyroidism in a significantly shorter time than the low dose regimen, i.e., 259.6 days and 305.5 days, respectively, p = 0.008). For the persistent hyperthyroid patients, the average total cost of treatment in the low dose group was significantly higher than that of the high dose group, i.e., 13,422.78 baht and 10,942.79 baht, respectively; p = 0.050). A high dose regimen of radioactive iodine treatment is more effective than the low dose regimen. The successful outcome of a high dose regimen occurred significantly earlier than that of the low dose regimen. For the persistent hyperthyroid patients, the average total cost in the low dose group was significantly higher than that of the high dose group.

  16. A comparison study on various low energy sources in interstitial prostate brachytherapy

    PubMed Central

    Bakhshabadi, Mahdi; Ghorbani, Mahdi; Knaup, Courtney; Meigooni, Ali S.

    2016-01-01

    Purpose Low energy sources are routinely used in prostate brachytherapy. 125I is one of the most commonly used sources. Low energy 131Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of 125I, 103Pd, and 131Cs sources in interstitial brachytherapy of prostate. Material and methods ProstaSeed 125I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of 103Pd and 131Cs were simulated with the same geometry as the ProstaSeed 125I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Results Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, 131Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the 103Pd source. Conclusions The higher initial absolute dose in cGy/(h.U) of 131Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the 103Pd source are advantages of this later brachytherapy source. Based on the total dose the 125I source has advantage over the others due to its longer half-life. PMID:26985200

  17. A comparison study on various low energy sources in interstitial prostate brachytherapy.

    PubMed

    Bakhshabadi, Mahdi; Ghorbani, Mahdi; Khosroabadi, Mohsen; Knaup, Courtney; Meigooni, Ali S

    2016-02-01

    Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachytherapy of prostate. ProstaSeed (125)I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of (103)Pd and (131)Cs were simulated with the same geometry as the ProstaSeed (125)I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, (131)Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the (103)Pd source. The higher initial absolute dose in cGy/(h.U) of (131)Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the (103)Pd source are advantages of this later brachytherapy source. Based on the total dose the (125)I source has advantage over the others due to its longer half-life.

  18. Prediction of obliteration after gamma knife surgery for cerebral arteriovenous malformations.

    PubMed

    Karlsson, B; Lindquist, C; Steiner, L

    1997-03-01

    To define the factors of importance for the obliteration of cerebral arteriovenous malformations (AVMs), thus making a prediction of the probability for obliteration possible. In 945 AVMs of a series of 1319 patients treated with the gamma knife during 1970 to 1990, the relationship between patient, AVMs, and treatment parameters on the one hand and the obliteration of the nidus on the other was analyzed. The obliteration rate increased both with increased minimum (lowest periphery) and average dose and decreased with increased AVM volume. The minimum dose to the AVMs was the decisive dose factor for the treatment result. The higher the minimum dose, the higher the chance for total obliteration. The curve illustrating this relation increased logarithmically to a value of 87%. A higher average dose shortened the latency to AVM obliteration. For the obliterated cases, the larger the malformation, the lower the minimum dose used. This prompted us to relate the obliteration rate to the product minimum dose (AVM volume)1/3 (K index). The obliteration rate increased linearly with the K index up to a value of approximately 27, and for higher K values, the obliteration rate had a constant value of approximately 80%. For the group of 273 cases treated with a minimum dose of at least 25 Gy, the obliteration rate at the study end point (defined as 2-yr latency) was 80% (95% confidence interval = 75-85%). If obliterations that occurred beyond the end point are included, the obliteration rate increased to 85% (81-89%). The probability of obliteration of AVMs after gamma knife surgery is related both to the lowest dose to the AVMs and the AVM volume, and it can be predicted using the K index.

  19. Molecular Simulation of Receptor Occupancy and Tumor Penetration of an Antibody and Smaller Scaffolds: Application to Molecular Imaging.

    PubMed

    Orcutt, Kelly D; Adams, Gregory P; Wu, Anna M; Silva, Matthew D; Harwell, Catey; Hoppin, Jack; Matsumura, Manabu; Kotsuma, Masakatsu; Greenberg, Jonathan; Scott, Andrew M; Beckman, Robert A

    2017-10-01

    Competitive radiolabeled antibody imaging can determine the unlabeled intact antibody dose that fully blocks target binding but may be confounded by heterogeneous tumor penetration. We evaluated the hypothesis that smaller radiolabeled constructs can be used to more accurately evaluate tumor expressed receptors. The Krogh cylinder distributed model, including bivalent binding and variable intervessel distances, simulated distribution of smaller constructs in the presence of increasing doses of labeled antibody forms. Smaller constructs <25 kDa accessed binding sites more uniformly at large distances from blood vessels compared with larger constructs and intact antibody. These observations were consistent for different affinity and internalization characteristics of constructs. As predicted, a higher dose of unlabeled intact antibody was required to block binding to these distant receptor sites. Small radiolabeled constructs provide more accurate information on total receptor expression in tumors and reveal the need for higher antibody doses for target receptor blockade.

  20. A study comparing the safety and efficacy of febuxostat, allopurinol, and benzbromarone in Chinese gout patients: a retrospective cohort study
.

    PubMed

    Zhou, Qiao; Su, Jiang; Zhou, Ting; Tian, Juan; Chen, Xixi; Zhu, Jing

    2017-02-01

    To evaluate and compare the safety and efficacy of three urate lowering agents: febuxostat, allopurinol, and benzbromarone, when used to treat Chinese gout patients. A total of 120 patients treated in our department from November 2011 to December 2014 were randomly selected and divided into four groups: febuxostat (40 mg per day), febuxostat (80 mg per day), allopurinol (100 mg, 3 × per day) or benzbromarone (50 mg per day), (n = 30 patients/group). The serum uric acid (UA) concentrations of the patients in each group were recorded and compared from week 2 through week 24 after the treatments, and all adverse events were evaluated to determine the safety of the various treatment regimens. Treatment with febuxostat (40 mg) significantly reduced serum UA levels to those achieved with allopurinol or benzbromarone treatment. The treatment with febuxostat (80 mg) produced the best therapeutic effect and achieved the targeted UA level as early as week 2. However, the total number of patients experiencing adverse events was significantly higher in the febuxostat 80-mg group. The incidences of abnormal liver function, hyperlipidemia, and gout flare were higher in both febuxostat treatment groups. The allopurinol group had a higher incidence of hypersensitivity, and the benzbromarone group had a higher incidence of renal dysfunction. Chinese patients treated with the 40-mg dose of febuxostat experienced a treatment effect and total rate of adverse events similar to those produced by allopurinol or benzbromarone. To achieve a better therapeutic effect, the dose of febuxostat can be elevated to 80 mg per day; however, patients receiving the higher dose must be closely monitored for signs of liver dysfunction. Febuxostat is an alternative treatment for Chinese gout patients who are at a much higher risk for severe cutaneous adverse reactions as well as for patients with a history of kidney stones.
.

  1. A rapid infusion protocol is safe for total dose iron polymaltose: time for change.

    PubMed

    Garg, M; Morrison, G; Friedman, A; Lau, A; Lau, D; Gibson, P R

    2011-07-01

    Intravenous correction of iron deficiency by total dose iron polymaltose is inexpensive and safe, but current protocols entail prolonged administration over more than 4 h. This results in reduced patient acceptance, and hospital resource strain. We aimed to assess prospectively the safety of a rapid intravenous protocol and compare this with historical controls. Consecutive patients in whom intravenous iron replacement was indicated were invited to have up to 1.5 g iron polymaltose by a 58-min infusion protocol after an initial 15-min test dose without pre-medication. Infusion-related adverse events (AE) and delayed AE over the ensuing 5 days were also prospectively documented and graded as mild, moderate or severe. One hundred patients, 63 female, mean age 54 (range 18-85) years were studied. Thirty-four infusion-related AE to iron polymaltose occurred in a total of 24 patients--25 mild, 8 moderate and 1 severe; higher than previously reported for a slow protocol iron infusion. Thirty-one delayed AE occurred in 26 patients--26 mild, 3 moderate and 2 severe; similar to previously reported. All but five patients reported they would prefer iron replacement through the rapid protocol again. The presence of inflammatory bowel disease (IBD) predicted infusion-related reactions (54% vs 14% without IBD, P < 0.001) and the serum C-reactive protein was higher in those with reactions (P = 0.043). Iron polymaltose can be successfully administered using a rapid total dose infusion protocol and was well accepted by patients. It offers significant cost, resource utilization and time benefits for the patient and hospital system. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  2. Recombinant FVIIa (NovoSeven) continuous infusion and total hip replacement in patients with haemophilia and high titre of inhibitors to FVIII: experience of two cases.

    PubMed

    Tagariello, G; De Biasi, E; Gajo, G B; Risato, R; Radossi, P; Davoli, P G; Traldi, A

    2000-09-01

    In this report we describe our experience of total hip replacement in two patients with severe haemophilia A and high titres of inhibitors to FVIII. We used rFVIIa replacement therapy by continuous infusion to perform the surgery. The total amount of rFVIIa used in these two patients was very similar but the manner of administration was quite different. In our experience, it is an advantage to use a higher dose for shorter periods than a lower dose for a longer treatment period. Tranexamic acid by continuous infusion, and parallel saline infusion were useful for good haemostasis and avoided local thrombophlebitis in the side of rFVIIa infusion.

  3. Effects of medetomidine on serum glucose in cattle calves.

    PubMed

    Tariq, Muhammad; Kalhoro, Amir Bukhsh; Sarwar, Mian Saeed; Khan, Hamayun; Ahmad, Shakoor; Hassan, Sayed Mubashir; Zahoor, Arshad

    2016-05-01

    An experimental study was carried out to compare physiological effects (serum glucose level) of medetomidine in Red Sindhi cattle calves at three different doses i.e. 8, 10 and 12µg/kg body weight intravenously. Medetomidine produced a dose dependent significant (P<0.01) increase in serum glucose level with a maximum increase observed at 30 minutes with 8µg/kg, 10μg/kg and 12μg/kg body weight respectively. Start of sedation, degree of sedation and total duration of sedation were all dose dependent and the values obtained were significantly (P<0.01) different from each other. It was observed that the sedation was rapid, deep and longer with the higher doses of medetomidine i.e. 12μg/kg. The results of the present study shows that medetomidine is a very effective and safest drug use as sedative for calves which in lower doses (8μg/kg) can be used as a pre-anesthetic and for restraining of the animal, while higher calculated doses (10μg/kg, 12μg/kg) can be used to execute the minor surgical procedures.

  4. Assessment of dose rate to terrestrial biota in the area around coal fired power plant applying ERICA tool and RESRAD BIOTA code.

    PubMed

    Ćujić, Mirjana; Dragović, Snežana

    2018-08-01

    This paper presents the environmental radiation risk assessment based on two software program approaches ERICA Tool (version 1.2) and RESRAD BIOTA (version 1.5) to estimate dose rates to terrestrial biota in the area around the largest coal fired power plant in Serbia. For dose rate assessment software's default reference animals and plants and the best estimated values of activity concentrations of 238 U, 234 U, 234 Th, 232 Th, 230 Th, 226 Ra, 210 Pb, 210 Po, 137 Cs in soil were used. Both approaches revealed the highest contribution to the internal dose rate due to 226 Ra and 210 Po, while 137 Cs contributed the most to the external dose rate. In the investigated area total dose rate to biota derived using ERICA Tool ranged from 0.3 to 14.4 μGy h -1 . The natural radionuclides exhibited significantly higher contribution to the total dose rate than the artificial one. In the investigated area, only dose rate for lichens and bryophytes exceeded ERICA Tool screening value of total dose rate of 10 μGy h -1 suggested as confident that environmental risks are negligible. The assessed total dose rates for reference animals and plants using RESRAD BIOTA were found to be 7 and 3 μGy h -1 , respectively. In RESRAD BIOTA - Level 3, 10 species (Lumbricus terrestris, Rana lessonae, Sciurus vulgaris, Anas platyrhynchos, Lepus europaeus, Vulpes vulpes, Capreolus capreolus, Suss crofa, Quercu srobur, Tilia spp.) representative for the study area were modeled. Among them the highest total dose rate (4.5 μGy h -1 ) was obtained for large mammals. Differences in the predicted dose rates to biota using the two software programs are the consequence of the difference in the values of transfer parameters used to calculate activity concentrations in biota. Doses of ionizing radiation estimated in this study will not exhibit deterministic effects at the population level. Thus, the obtained results indicate no significant radiation impact of coal fired power plant operation on terrestrial biota. This paper confirms the use ERICA Tool and RESRAD BIOTA softwares as flexible and effective means of radiation impact assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The effect of aspirin dosing on platelet function in diabetic and nondiabetic patients: an analysis from the aspirin-induced platelet effect (ASPECT) study.

    PubMed

    DiChiara, Joseph; Bliden, Kevin P; Tantry, Udaya S; Hamed, Miruais S; Antonino, Mark J; Suarez, Thomas A; Bailon, Oscar; Singla, Anand; Gurbel, Paul A

    2007-12-01

    Diabetic patients may have a higher prevalence of platelet aspirin resistance than nondiabetic patients. Our goal was to analyze platelet aspirin responsiveness to various aspirin doses in diabetic and nondiabetic patients. We examined the effect of aspirin (81, 162, and 325 mg/day for 4 weeks each) on platelet aspirin responsiveness in 120 stable outpatients (30 diabetic patients and 90 nondiabetic patients) with coronary artery disease (CAD) using light transmittance aggregometry (LTA), VerifyNow, platelet function analyzer (PFA)-100, and levels of urinary 11-dehydro-thromboxane B(2) (11-dh-TxB(2)). In the total group, a low prevalence (0-2%) of aspirin resistance was observed with all aspirin doses as determined by arachidonic acid-induced LTA. Aspirin resistance was higher at the 81-mg dose in diabetic versus nondiabetic patients using collagen-induced LTA (27 vs. 4%, P = 0.001), VerifyNow (13 vs. 3%, P = 0.05), and urinary 11-dh-TxB(2) (37 vs. 17%, P = 0.03). Diabetic patients treated with 81 mg exhibited higher platelet function measured by VerifyNow, collagen- and ADP-induced LTA, and 11-dh-TxB(2) levels (P

  6. Comparison of psychodrug prescription patterns in patients diagnosed with bipolar disorder and addiction.

    PubMed

    Barral, Diego; Barral, Fátima; Cruz, Nuria; Molina, Juan D; Sánchez, Victoria; Rosique, Teresa

    2016-11-01

    To describe if there are differences in the prescription of psychodrug at discharge between bipolar disorder patients with or without addiction. We review all the psychotropic drugs dispensed to inpatients of a brief hospitalization psychiatric unit diagnosed as having bipolar disorder at time of discharge. We recluted 225 patients over 18 years old on their last manic episode, between the year 2000 and 2010. We classify them according to the comorbid presence or not of a substance abuse or dependence disorder. Prevalence of addiction was 24%. We found no differences between groups in the number of psychotropic drugs prescribed at discharge. The prescription pattern of mood stabilizers and benzodiazepines was similar in both groups. We detect differences in the total daily dose of antipsychotic, expressed as risperidone equivalents (5.86 ± 4.62 mg in addictions group versus 4.67 ± 3.20 mg in control group, p=0.042) and in the total daily dose of biperideno (4.80 ± 1.78 mg in addictions group versus 3.20 ± 1.03 mg in the control group, p=0.044). Contrary to our expectations, both groups were similar in psychopharmacological prescription patterns at discharge. However, those patients with substance abuse disorder had higher doses of antipsychotics and higher dose biperiden at discharge.

  7. Somatotype, the risk of hydroxychloroquine retinopathy, and safe daily dosing guidelines.

    PubMed

    Browning, David J; Lee, Chong

    2018-01-01

    The aim of this study was to determine whether somatotype influences the risk of hydroxychloroquine (HC) retinopathy (HCR) and whether dosing by real body weight (RBW), ideal body weight (IBW), or the lesser of these better predicts the risk of HCR. A total of 565 patients taking HC for whom height and weight were recorded and a sensitive ancillary testing modality was used including 10-2 visual fields, spectral domain optical coherence tomography, fundus autofluorescence imaging, and multifocal electroretinography were enrolled. Body mass index (BMI) was compared for patients without and with HCR. Logistic regression models of age, cumulative dose, and daily dosing based on RBW, IBW, or lesser of these were compared. Area under the curve (AUC) of receiver operating characteristic plots was used to assess the diagnostic accuracy of RBW, IBW, and lesser of these guidelines for safe dosing. Probability plots for the risk of retinopathy versus BMI were compared for the different recommended guidelines on safe dosing. A total of 41 patients had HCR. The median BMI was 27.6 (interquartile range [IQR] 24.3, 32.6) and 24.0 (IQR 21.0, 31.6) for patients without and with HCR ( P =0.0102), respectively. AUC for univariate receiver operating characteristic plots of retinopathy versus dosing by RBW, IBW, and lesser of these was 0.71, 0.72, and 0.76, respectively. AUC for multivariate receiver operating characteristic plots of retinopathy versus models incorporating gender, age, cumulative dose, and BMI and differing by including dosing by RBW, IBW, and lesser of these was 0.82, 0.82, and 0.83, respectively. For all of the multivariate logistic models, the risk of retinopathy was higher for lower BMIs. Short, asthenic women are at higher risk for HCR. The 2011 American Academy of Ophthalmology (AAO) guidelines are safer for short, obese women. The 2016 AAO guidelines are safer for short, asthenic patients. Choosing daily dosing based on the lesser of the RBW and IBW guidelines is safer for all patients.

  8. Dose-volume effects in pathologic lymph nodes in locally advanced cervical cancer.

    PubMed

    Bacorro, Warren; Dumas, Isabelle; Escande, Alexandre; Gouy, Sebastien; Bentivegna, Enrica; Morice, Philippe; Haie-Meder, Christine; Chargari, Cyrus

    2018-03-01

    In cervical cancer patients, dose-volume relationships have been demonstrated for tumor and organs-at-risk, but not for pathologic nodes. The nodal control probability (NCP) according to dose/volume parameters was investigated. Patients with node-positive cervical cancer treated curatively with external beam radiotherapy (EBRT) and image-guided brachytherapy (IGABT) were identified. Nodal doses during EBRT, IGABT and boost were converted to 2-Gy equivalent (α/β = 10 Gy) and summed. Pathologic nodes were followed individually from diagnosis to relapse. Statistical analyses comprised log-rank tests (univariate analyses), Cox proportional model (factors with p ≤ 0.1 in univariate) and Probit analyses. A total of 108 patients with 254 unresected pathological nodes were identified. The mean nodal volume at diagnosis was 3.4 ± 5.8 cm 3 . The mean total nodal EQD2 doses were 55.3 ± 5.6 Gy. Concurrent chemotherapy was given in 96%. With a median follow-up of 33.5 months, 20 patients (18.5%) experienced relapse in nodes considered pathologic at diagnosis. Overall nodal recurrence rate was 9.1% (23/254). On univariate analyses, nodal volume (threshold: 3 cm 3 , p < .0001) and lymph node dose (≥57.5 Gy α/β10 , p = .039) were significant for nodal control. The use of simultaneous boost was borderline for significance (p = .07). On multivariate analysis, volume (HR = 8.2, 4.0-16.6, p < .0001) and dose (HR = 2, 1.05-3.9, p = .034) remained independent factors. Probit analysis combining dose and volume showed significant relationships with NCP, with increasing gap between the curves with higher nodal volumes. A nodal dose-volume effect on NCP is demonstrated for the first time, with increasing NCP benefit of additional doses to higher-volume nodes. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Clinical evaluation of paroxetine in post-traumatic stress disorder (PTSD): 52-week, non-comparative open-label study for clinical use experience.

    PubMed

    Kim, Yoshiharu; Asukai, Nozomu; Konishi, Takako; Kato, Hiroshi; Hirotsune, Hideto; Maeda, Masaharu; Inoue, Hirotaka; Narita, Hiroyasu; Iwasaki, Masaru

    2008-12-01

    The present study was a 52-week, non-comparative, open-label study of flexible dose paroxetine (20-40 mg) in 52 Japanese post-traumatic stress disorder (PTSD) patients in order to obtain clinical experience regarding efficacy and safety in regular clinical practice. Efficacy was measured using the Clinician-Administered PTSD Scale One Week Symptom Status Version (CAPS-SX). The mean change from baseline in CAPS-SX total score was -19.1, -22.8 and -32.3 at weeks 4, 12 and 52, respectively, and that in the Clinical Global Impression (CGI) Severity of Illness score was -1.1 at week 12 and -1.7 at week 52. A total of 46.9% were CGI responders at week 12, while 67.3% were improved on the CGI at week 52. Of 52 subjects who entered into the drug treatment, 25 completed the study. Only one patient withdrew from the study due to lack of efficacy. In patients who were rated as 'moderately ill' or less at baseline, the proportion of CGI responders at end-point was higher at a dose of 20 mg/day than at higher doses, whereas in patients rated as 'markedly ill' or more, it was higher at 30 and 40 mg/day, suggesting that severely ill patients could benefit from higher doses. Paroxetine appeared generally tolerated in short- and long-term use, and the safety profile in this study was consistent with international trials and other Japanese populations (i.e. patients suffering from depression, panic disorder or obsessive-compulsive disorder). Although the study was not conducted in double-blind fashion, the current findings suggest that paroxetine may contribute to clinically meaningful improvement that is maintained during long-term use and is generally well tolerated.

  10. Assessment of normal tissue complications following prostate cancer irradiation: Comparison of radiation treatment modalities using NTCP models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takam, Rungdham; Bezak, Eva; Yeoh, Eric E.

    2010-09-15

    Purpose: Normal tissue complication probability (NTCP) of the rectum, bladder, urethra, and femoral heads following several techniques for radiation treatment of prostate cancer were evaluated applying the relative seriality and Lyman models. Methods: Model parameters from literature were used in this evaluation. The treatment techniques included external (standard fractionated, hypofractionated, and dose-escalated) three-dimensional conformal radiotherapy (3D-CRT), low-dose-rate (LDR) brachytherapy (I-125 seeds), and high-dose-rate (HDR) brachytherapy (Ir-192 source). Dose-volume histograms (DVHs) of the rectum, bladder, and urethra retrieved from corresponding treatment planning systems were converted to biological effective dose-based and equivalent dose-based DVHs, respectively, in order to account for differences inmore » radiation treatment modality and fractionation schedule. Results: Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75 Gy/fraction delivered five times/week to total dose of 55 Gy), NTCP of the rectum, bladder, and urethra were less than those for standard fractionated 3D-CRT using a four-field technique (32 fractions of 2 Gy/fraction delivered five times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6%, respectively) following the dose-escalated four-field 3D-CRT (2 Gy/fraction to total dose of 74 Gy) were the highest among analyzed treatment techniques. The average NTCP for the rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT. Conclusions: Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques other than the urethra because of much smaller volumes irradiated to higher doses. Among analyzed normal tissues, the femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues.« less

  11. Long-term results and prognostic factors of fractionated strontium-90 eye applicator for pterygium.

    PubMed

    Viani, Gustavo Arruda; Stefano, Eduardo Jose; De Fendi, Ligia Issa; Fonseca, Ellen Carrara

    2008-11-15

    To evaluate the long-term safety, effectiveness, and prognostic factors of fractionated postoperative beta-irradiation. Between 1993 and 2005, 623 patients with 737 pterygium lesions were treated with a strontium-90 eye applicator after surgical excision. The median follow-up period was 60 months (range, 6.7-139.5). Of the 737 lesions, 644 were primary and 93 were recurrences after surgical removal alone. Fractionated radiotherapy (RT) to a total dose of 35 Gy in five to seven fractions was used. A total of 73 local pterygium recurrences (9.9%) were noted. Of the recurrent cases, 80% were noted within 3 years after treatment. The 5- and 10-year probability of local control was 90% and 88%, respectively. The multivariate analysis for all cases demonstrated that gender, age, total radiation dose, recurrent pterygia, and interval between surgery and RT affected the overall local control rate. Late toxicities that might have been associated with strontium-90 RT included scleromalacia (scleral thinning) in nine eyes, adhesion of the eyelids in eight, cataracts in six, and scleral ulcer in five eyes. Fractionated strontium-90 RT to a total dose of approximately 35 Gy in five to seven fractions results in a similar local control rate as higher doses in other series, with an acceptable complication rate.

  12. In vitro permeation and disposition of niacinamide in silicone and porcine skin of skin barrier-mimetic formulations.

    PubMed

    Haque, Tasnuva; Lane, Majella E; Sil, Bruno C; Crowther, Jonathan M; Moore, David J

    2017-03-30

    Niacinamide (NIA) is an amide form of vitamin B3 which is used in cosmetic formulations to improve various skin conditions and it has also been shown to increase stratum corneum thickness following repeated application. In this study, three doses (5, 20 and 50μL per cm 2 ) of two NIA containing oil-in-water skin barrier-mimetic formulations were evaluated in silicone membrane and porcine ear skin and compared with a commercial control formulation. Permeation studies were conducted over 24h in Franz cells and at the end of the experiment membranes were washed and niacinamide was extracted. For the three doses, retention or deposition of NIA was generally higher in porcine skin compared with silicone membrane, consistent with the hydrophilic nature of the active. Despite the control containing a higher amount of active, comparable amounts of NIA were deposited in skin for all formulations for all doses; total skin absorption values (permeation and retention) of NIA were also comparable across all formulations. For infinite (50μL) and finite (5μL) doses the absolute permeation of NIA from the control formulation was significantly higher in porcine skin compared with both test formulations. This likely reflects differences in formulation components and/or presence of skin penetration enhancers in the formulations. Higher permeation for the 50 and 20μL dose was also evident in porcine skin compared with silicone membrane but the opposite is the case for the finite dose. The findings point to the critical importance of dose and occlusion when evaluating topical formulations in vitro and also the likelihood of exaggerated effects of excipients on permeation at infinite and pseudo-finite dose applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Dissipation kinetics and effect of processing on imidacloprid and its metabolites in cardamom (Elettaria cardamomum Maton).

    PubMed

    Pratheeshkumar, N; Chandran, M; Beevi, S Naseema; Mathew, Thomas Biju; George, Thomas; Paul, Ambily; Xavier, George; Ravi, K Prathibha; Kumar, S Visal; Rajith, R

    2016-01-01

    Dissipation behaviour of the chloronicotinyl insecticide, imidacloprid (Tatamida 17.8 % SL), in fresh and cured cardamom capsules was studied following application at doses 20 and 40 g a.i. ha(-1) in a cardamom plantation of Indian Cardamom Hills (ICH), Idukki, Kerala, India. A single-laboratory ultra performance liquid chromatography mass spectrometry (UPLC-MS/MS) method was developed and validated for the estimation of imidacloprid and its six metabolites (5-hydroxy, olefin, guanidine, urea, 6-chloronicotinic acid and nitrosimine) in fresh and cured cardamom. At the lower dose, the initial deposits of total imidacloprid residues were 1.91 and 7.23 μg g(-1), respectively, in fresh and cured cardamom. At the higher dose, the initial residues were 3.94 and 14.72 μg g(-1), respectively, in fresh and cured capsules. The residues dissipated below the quantitation level of 0.01 μg g(-1) after 21 and 28 days at lower dose and after 28 days for both at higher dose. The half-lives of imidacloprid in fresh and cured cardamom were 4.02 and 3.63 days, respectively, at lower dose and 3.61 days for both at higher dose. The waiting periods of imidacloprid on fresh and cured cardamom at lower and higher doses were 21.40, 27.10, 23.85 and 30.70 days, respectively. The mean processing factor of imidacloprid was 3.96 at 20 g a.i. ha(-1). Amongst metabolites of imidacloprid, urea had maximum residues in fresh and cured cardamom followed by 5-hydroxy and guanidine. Other metabolites such as 6-chloronicotinic acid, olefin and nitrosimine were not detected either in fresh or cured cardamom.

  14. Nitrogen split dose fertilization, plant age and frost effects on phytochemical content and sensory properties of curly kale (Brassica oleracea L. var. sabellica).

    PubMed

    Groenbaek, Marie; Jensen, Sidsel; Neugart, Susanne; Schreiner, Monika; Kidmose, Ulla; Kristensen, Hanne L

    2016-04-15

    We investigated how concentrations of sensory relevant compounds: glucosinolates (GLSs), flavonoid glycosides, hydroxycinnamic acid derivatives and sugars in kale responded to split dose and reduced nitrogen (N) fertilization, plant age and controlled frost exposure. In addition, frost effects on sensory properties combined with N supply were assessed. Seventeen week old kale plants showed decreased aliphatic GLSs at split dose N fertilization; whereas reduced N increased aliphatic and total GLSs. Ontogenetic effects were demonstrated for all compounds: sugars, aliphatic and total GLSs increased throughout plant development, whereas kaempferol and total flavonoid glycosides showed higher concentrations in 13 week old plants. Controlled frost exposure altered sugar composition slightly, but not GLSs or flavonoid glycosides. Reduced N supply resulted in less bitterness, astringency and pungent aroma, whereas frost exposure mainly influenced aroma and texture. N treatment explained most of the sensory variation. Producers should not rely on frost only to obtain altered sensory properties. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Comparison of microdose flare-up and antagonist multiple-dose protocols for poor-responder patients: a randomized study.

    PubMed

    Demirol, Aygul; Gurgan, Timur

    2009-08-01

    To compare the efficacy of the microdose flare-up and multiple-dose antagonist protocols for poor-responder patients in intracytoplasmic sperm injection-ET cycles. A randomized, prospective study. Center for assisted reproductive technology in Turkey. Ninety patients with poor ovarian response in a minimum of two previous IVF cycles. All women were prospectively randomized into two groups by computer-assisted randomization. The patients in group 1 were stimulated according to the microdose flare-up protocol (n = 45), while the patients in group 2 were stimulated according to antagonist multiple-dose protocol (n = 45). The mean number of mature oocytes retrieved was the primary outcome measure, and fertilization rate, implantation rate per embryo, and clinical pregnancy rates were secondary outcome measures. The mean age of the women, the mean duration of infertility, basal FSH level, and the number of previous IVF cycles were similar in both groups. The total gonadotropin dose used was significantly higher in group 2, while the number of oocytes retrieved was significantly greater in group 1. Although the fertilization and clinical pregnancy rates were nonsignificantly higher in group 1 compared with group 2, the implantation rate was significantly higher in the microdose flare-up group than in the multiple-dose antagonist group (22% vs. 11%). The microdose flare-up protocol seems to have a better outcome in poor-responder patients, with a significantly higher mean number of mature oocytes retrieved and higher implantation rate.

  16. Opioid Analgesics and Adverse Outcomes among Hemodialysis Patients.

    PubMed

    Ishida, Julie H; McCulloch, Charles E; Steinman, Michael A; Grimes, Barbara A; Johansen, Kirsten L

    2018-05-07

    Patients on hemodialysis frequently experience pain and may be particularly vulnerable to opioid-related complications. However, data evaluating the risks of opioid use in patients on hemodialysis are limited. Using the US Renal Data System, we conducted a cohort study evaluating the association between opioid use (modeled as a time-varying exposure and expressed in standardized oral morphine equivalents) and time to first emergency room visit or hospitalization for altered mental status, fall, and fracture among 140,899 Medicare-covered adults receiving hemodialysis in 2011. We evaluated risk according to average daily total opioid dose (>60 mg, ≤60 mg, and per 60-mg dose increment) and specific agents (per 60-mg dose increment). The median age was 61 years old, 52% were men, and 50% were white. Sixty-four percent received opioids, and 17% had an episode of altered mental status (15,658 events), fall (7646 events), or fracture (4151 events) in 2011. Opioid use was associated with risk for all outcomes in a dose-dependent manner: altered mental status (lower dose: hazard ratio, 1.28; 95% confidence interval, 1.23 to 1.34; higher dose: hazard ratio, 1.67; 95% confidence interval, 1.56 to 1.78; hazard ratio, 1.29 per 60 mg; 95% confidence interval, 1.26 to 1.33), fall (lower dose: hazard ratio, 1.28; 95% confidence interval, 1.21 to 1.36; higher dose: hazard ratio, 1.45; 95% confidence interval, 1.31 to 1.61; hazard ratio, 1.04 per 60 mg; 95% confidence interval, 1.03 to 1.05), and fracture (lower dose: hazard ratio, 1.44; 95% confidence interval, 1.33 to 1.56; higher dose: hazard ratio, 1.65; 95% confidence interval, 1.44 to 1.89; hazard ratio, 1.04 per 60 mg; 95% confidence interval, 1.04 to 1.05). All agents were associated with a significantly higher hazard of altered mental status, and several agents were associated with a significantly higher hazard of fall and fracture. Opioids were associated with adverse outcomes in patients on hemodialysis, and this risk was present even at lower dosing and for agents that guidelines have recommended for use. Copyright © 2018 by the American Society of Nephrology.

  17. Predictors of Excess Patient Radiation Exposure During Chronic Total Occlusion Coronary Intervention: Insights from a Contemporary Multicenter Registry

    PubMed Central

    Christakopoulos, Georgios E.; Christopoulos, Georgios; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W.; Jaffer, Farouc A.; Wyman, Michael R.; Lombardi, William L.; Tarar, Muhammad Nauman J.; Grantham, J. Aaron; Kandzari, David; Lembo, Nicholas; Moses, Jeffrey W.; Kirtane, Ajay; Parikh, Manish; Green, Philip; Finn, Matthew; Garcia, Santiago; Doing, Anthony; Hatem, Raja; Thompson, Craig A.; Banerjee, Subhash; Brilakis, Emmanouil S.

    2016-01-01

    Background High patient radiation dose during chronic total occlusion (CTO) percutaneous coronary intervention (PCI) may lead to procedural failure and radiation skin injury. Methods We examined the association between several clinical and angiographic variables on patient air kerma (AK) radiation dose among 748 consecutive CTO PCIs performed at 9 experienced US centers between May 2012 and May 2015. Results Mean age was 65±10 years, 87% of patients were men, and 35% had prior coronary artery bypass graft surgery (CABG). Technical and procedural success was 92% and 90%, respectively. The median patient AK dose was 3.40 (2.00, 5.40) Gray and 34% of the patients received >4.8 Gray (high radiation exposure). On univariable analysis male gender (p=0.016), high body mass index (p<0.001), history of hyperlipidemia (p=0.023), prior CABG (p<0.001), moderate or severe calcification (p<0.001), tortuosity (p<0.001), proximal cap ambiguity (p=0.001), distal cap at a bifurcation (p=0.006), longer CTO occlusion length (p<0.001), blunt/no blunt stump (p<0.001), and center (<0.001) were associated with higher patient AK dose. On multivariable analysis high body mass index (p<0.001), prior CABG (p=0.005), moderate or severe calcification (p=0.005), longer CTO occlusion length (p<0.001), and center (p<0.001) were independently associated with higher patient AK dose. Conclusions Approximately 1 in 3 patients undergoing CTO PCI receives high AK radiation dose (>4.8 Gray). Several baseline clinical and angiographic characteristics can help predict the likelihood of high radiation dose and assist with intensifying efforts to reduce radiation exposure for the patient and the operator. PMID:28169091

  18. The influences of adrenaline dosing frequency and dosage on outcomes of adult in-hospital cardiac arrest: A retrospective cohort study.

    PubMed

    Wang, Chih-Hung; Huang, Chien-Hua; Chang, Wei-Tien; Tsai, Min-Shan; Yu, Ping-Hsun; Wu, Yen-Wen; Hung, Kuan-Yu; Chen, Wen-Jone

    2016-06-01

    To investigate the influence of dosing frequency and dosage of adrenaline on outcomes of cardiopulmonary resuscitation (CPR). We conducted a retrospective observational study in a single medical centre and included adult patients who had suffered an in-hospital cardiac arrest between 2006 and 2012. We used multivariable logistic regression analysis to evaluate the associations between independent variables and outcomes. Adrenaline average dosing frequency was calculated as the total dosage of adrenaline administered during CPR divided by the duration of CPR. Body weight (BW) was analysed as an interaction term to investigate the effect of adrenaline dosage on outcomes. Favourable neurological outcome was defined as a score of 1 or 2 on the Cerebral Performance Category scale at hospital discharge. We included 896 patients in the analysis. After adjusting for multiple confounding factors, including CPR duration, the results indicated that higher adrenaline dosing frequency was associated with lower rates of survival (odds ratio (OR): 0.05, 95% confidence interval (CI): 0.01-0.23) and favourable neurological outcome at hospital discharge (OR: 0.02, 95% CI: 0.002-0.16). A significant interaction was noted between total adrenaline dosage and BW, which indicated that, with the same adrenaline dosage, the outcomes for patients with BW≥82.5kg would be worse than those for patients with lower BW. Higher adrenaline average dosing frequency may be associated with worse outcomes after CPR. Besides, according to current recommendations, patients with BW above 82.5kg may not receive adequate dose of adrenaline. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Dose-dense and less dose-intense Total Therapy 5 for gene expression profiling-defined high-risk multiple myeloma.

    PubMed

    Jethava, Y; Mitchell, A; Zangari, M; Waheed, S; Schinke, C; Thanendrarajan, S; Sawyer, J; Alapat, D; Tian, E; Stein, C; Khan, R; Heuck, C J; Petty, N; Avery, D; Steward, D; Smith, R; Bailey, C; Epstein, J; Yaccoby, S; Hoering, A; Crowley, J; Morgan, G; Barlogie, B; van Rhee, F

    2016-07-29

    Multiple myeloma (MM) is a heterogeneous disease with high-risk patients progressing rapidly despite treatment. Various definitions of high-risk MM are used and we reported that gene expression profile (GEP)-defined high risk was a major predictor of relapse. In spite of our best efforts, the majority of GEP70 high-risk patients relapse and we have noted higher relapse rates during drug-free intervals. This prompted us to explore the concept of less intense drug dosing with shorter intervals between courses with the aim of preventing inter-course relapse. Here we report the outcome of the Total Therapy 5 trial, where this concept was tested. This regimen effectively reduced early mortality and relapse but failed to improve progression-free survival and overall survival due to relapse early during maintenance.

  20. ²¹⁰Po in the diet at Seville (Spain) and its contribution to the dose by ingestion.

    PubMed

    Díaz-Francés, I; Mantero, J; Díaz-Ruiz, J; Manjón, G; García-Tenorio, R

    2016-02-01

    The activity concentrations of (210)Po have been determined in a total of 24 representative diet samples from Seville (south of Spain), inferring from the obtained values the annual intakes of (210)Po by ingestion of the affected population and the corresponding committed effective doses. The annual intakes of (210)Po and, consequently, the corresponding doses of this radionuclide show a high variability in correspondence with the variability in the composition of the analysed samples over time, and their magnitude is comparable with the estimated ones in other regions/countries of the world with similar diet habits (countries where the marine products have a considerable weight in the diets). Committed effective doses by ingestion higher than 0.1 mSv y(-1) have been estimated exclusively for (210)Po, reflecting the importance of this radionuclide and this route of incorporation in the magnitude of the total doses received by the affected population from natural sources. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Carcinoma of the vagina. [Complications following whole-pelvis. gamma. irradiation and radium implant therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcus, R.B. Jr.; Million, R.R.; Daly, J.W.

    1978-11-01

    Twenty-two patients with Stage I through IV primary vaginal squamous cell carcinomas treated for cure with radiation therapy are reviewed, with particular emphasis on the relationship of dose to complications and local control. All but 2 patients received 4000 to 6000 rad whole pelvis irradiation plus at least one radium application. Local control was 91%, with an absolute 2-year disease-free survival of 82%. The degree of anaplasia was found to influence prognosis, with all local and distant failures resulting from high-grade lesions. The complication rate was modest, with no fistulae or serious bowel complications. An analysis of total dose (externalmore » plus radium) with respect to local failure and complications showed that no major complications occurred at a combined dose below 9000 rad. An analysis of the individual contributions of external irradiation and radium implants showed that all but one very minor complication occurred at a radium dose of 4000 rad or higher. From these data, overall treatment planning and total dose recommendations are made.« less

  2. Nicotine replacement prescribing trends in a large psychiatric hospital, before and after implementation of a hospital-wide smoking ban.

    PubMed

    Scharf, Deborah; Fabian, Tanya; Fichter-DeSando, Cecilia; Douaihy, Antoine

    2011-06-01

    We examined prescribing patterns for nicotine replacement therapies (NRTs) in a large psychiatric hospital, before and after the implementation of a smoking ban. We extracted 5 years of NRT utilization data from hospital pharmacy records. The ban went into effect on January 1, 2007. Data reflect NRT prescriptions from 2 years before and 3 years after the ban, and N = 30,908 total inpatient hospital admissions. The monthly rate of total NRT prescriptions increased after the ban from M = 254.25 (SD = 126.60) doses per month to M = 4,467.52 (SD = 1,785.87) doses per month (>1,700% increase, p < .0001). After the smoking ban, clinicians prescribed higher doses of transdermal (but not oral) NRT (Tukey, p < .0001). Comparisons of NRT prescribing across hospital units tentatively suggested that patients being treated on the substance use disorders unit were prescribed more doses of NRT, as well as higher doses of NRT compared with patients on other units. Analysis of trends over time showed no apparent downward trend for NRT usage during the 3 years following the smoking ban, suggesting that clinicians continued to treat nicotine dependence after smoking was restricted. Clinicians are more likely to identify and treat symptoms of nicotine withdrawal when smoking is restricted. Hospitals should consider monitoring prescriptions for NRT as part of their ongoing quality assurance practices so that patients receive aggressive treatment of nicotine withdrawal symptoms--an essential component of high-quality patient care.

  3. Adaptive radiation therapy of prostate cancer

    NASA Astrophysics Data System (ADS)

    Wen, Ning

    ART is a close-loop feedback algorithm which evaluates the organ deformation and motion right before the treatment and takes into account dose delivery variation daily to compensate for the difference between planned and delivered dose. It also has potential to allow further dose escalation and margin reduction to improve the clinical outcome. This retrospective study evaluated ART for prostate cancer treatment and radiobiological consequences. An IRB approved protocol has been used to evaluate actual dose delivery of patients with prostate cancer undergoing treatment with daily CBCT. The dose from CBCT was measured in phantom using TLD and ion chamber techniques in the pelvic scan setting. There were two major findings from the measurements of CBCT dose: (1) the lateral dose distribution was not symmetrical, with Lt Lat being ˜40% higher than Rt Lat and (2) AP skin dose varies with patient size, ranging 3.2--6.1 cGy for patient's AP separation of 20--33 cm (the larger the separation, the less the skin dose) but lateral skin doses depend little on separations. Dose was recalculated on each CBCT set under the same treatment plan. DIR was performed between SIM-CT and evaluated for each CT sets. Dose was reconstructed and accumulated to reflect the actual dose delivered to the patient. Then the adaptive plans were compared to the original plan to evaluate tumor control and normal tissue complication using radiobiological model. Different PTV margins were also studied to access margin reduction techniques. If the actual dose delivered to the PTV deviated significantly from the prescription dose for the given fractions or the OAR received higher dose than expected, the treatment plan would be re-optimized based on the previously delivered dose. The optimal schedule was compared based on the balance of PTV dose coverage and inhomogeneity, OAR dose constraints and labor involved. DIR was validated using fiducial marker position, visual comparison and UE. The mean and standard deviation of markers after rigid registration in L-R direction was 0 and 1 mm. But the mean was 2--4 mm in the A-P and S-I direction and standard deviation was about 2 mm. After DIR, the mean in all three directions became 0 and standard deviation was within sub millimeter. UE images were generated for each CT set and carefully reviewed in the prostate region. DIR provided accurate transformation matrix to be used for dose reconstruction. The delivered dose was evaluated with radiobiological models. TCP for the CTV was calculated to evaluate tumor control in different margin settings. TCP calculated from the reconstructed dose agreed within 5% of the value in the plan for all patients with three different margins. EUD and NTCP were calculated to evaluate reaction of rectum to radiation. Similar biological evaluation was performed for bladder. EUD of actual dose was 3%--9% higher than that of planned dose of patient 1--3, 11%--20% higher of patient 4--5. Smaller margins could not reduce late GU toxicity effectively since bladder complication was directly related to Dmax which was at the same magnitude in the bladder no matter which margin was applied. Re-optimization was performed at the 10th, 20th , 30th, and 40th fraction to evaluate the effectiveness to limit OAR dose while maintaining the target coverage. Reconstructed dose was added to dose from remaining fractions after optimization to show the total dose patient would receive. It showed that if the plan was re-optimized at 10th or 20th fraction, total dose to rectum and bladder were very similar to planned dose with minor deviations. If the plan was re-optimized at the 30th fraction, since there was a large deviation between reconstructed dose and planned dose to OAR, optimization could not limit the OAR dose to the original plan with only 12 fractions left. If the re-optimization was done at the 40th fraction, it was impossible to compensate in the last 2 fractions. Large deviations of total dose to bladder and rectum still existed while dose inhomogeneity to PTV was significantly increased due to hard constraints set in the optimization to reduce OAR dose. In summary, ART did not show improvements in TCP if the patient was setup with CBCT. However, EUD of rectum and bladder was increased significantly due to tissue deformation which varied daily. With the power of ART, margins added to the CTV could be further reduced to preserve critical organs surrounding the target. (Abstract shortened by UMI.)

  4. Prescribing patterns and the use of therapeutic drug monitoring of psychotropic medication in a psychiatric high-security unit.

    PubMed

    Castberg, Ingrid; Spigset, Olav

    2008-10-01

    The aim of this study was to investigate the use of psychotropic medication and therapeutic drug monitoring in a high-security psychiatric unit and to compare the doses and serum concentrations both with the recommended intervals and with the doses and serum concentrations in a control group. One hundred thirty-two patients were admitted in the period from January 2000 to December 2005. All available samples were used when comparing serum concentrations and doses with the recommended ranges. For the comparison of doses and serum concentration-to-dose (C:D) ratios with the control group only 1 sample from each patient was used. A total of 459 analyses of 27 different drugs in samples from 8 women and 73 men were included. The median number of therapeutic drug monitoring analyses per patient was 4 (range 1-29). Thirty-seven of the 81 patients (46%) used 2 or more antipsychotics at the same time. Clozapine, lamotrigine, olanzapine, quetiapine, ziprasidone, and zuclopenthixol were often given in doses above the recommended. The serum levels were frequently above those recommended for clozapine, olanzapine, quetiapine, risperidone, ziprasidone, and zuclopenthixol. The serum levels were significantly higher in the study group than in the control group for clozapine, lamotrigine, quetiapine, and zuclopenthixol. The given dose was significantly higher in the study group than in the control group for clozapine, lamotrigine and zuclopenthixol. The C:D ratio was significantly lower in the study group than in the control group for olanzapine but higher for quetiapine. The non-evidence based practice of high-dose polypharmacy with several antipsychotics is widely used in this unit. The use of higher doses in the study group than in the control group was not due to differences in metabolism or adherence to treatment between the 2 groups. The frequent use of therapeutic drug monitoring did not seem to have a great impact on the prescribed doses.

  5. SOME CHANGES IN THE CARBOHYDRATE METABOLISM AND THE ALBUMIN FRACTION OF THE BLOOD SERUM OF RABBITS IN CASE OF CHRONIC TREATMENT WITH IRON-59 (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orlyanskaya, R.L.

    1962-01-01

    A study was undertaken to determine the effect of chronic daily poisoning of rabbits with Fe/sup 59/on the sugar content of the blood, the albumin fraction, and the total albumin content after treatment with glucose. The results indicated that daily administration of 1 and 10 mu C/kg of body weight of Fe/sup 59/ for a total of 16 months causes only a slight change in the level of the blood sugar; only a chronic exposure to the higher dose resulted in a slight reduction in the sugar level. These animals also exhibited a tendency toward hypoglycemia. No changes were notedmore » in the total albumin content of the serum. Exposure to the higher dose for 6 months caused a reduction of the albumin fraction and a corresponding increase of the globulin content. The A/G ratio was found to decrease first, followed by an increase after a few months. (TTT)« less

  6. Evaluation of the mutagenicity of alkylating agents, methylnitrosourea and temozolomide, using the rat Pig-a assay with total red blood cells or reticulocytes.

    PubMed

    Muto, Shigeharu; Yamada, Katsuya; Kato, Tatsuya; Ando, Masamitsu; Inoue, Yoshimi; Iwase, Yumiko; Uno, Yoshifumi

    2016-11-15

    A collaborative study of the endogenous phosphatidylinositol glycan class A (Pig-a) gene mutation assay was conducted by the Japanese Environmental Mutagen Society/Mammalian Mutagenicity Study Group with a single-dosing regimen of test chemicals administered to male rats. As a part of the study, two DNA alkylating agents, methylnitrosourea (MNU) and temozolomide (TMZ), were dosed by single oral gavage at 25, 50, and 100mg/kg body weight. Pig-a mutant analysis of total red blood cells (RBCs; RBC Pig-a assay) and reticulocytes (RETs; PIGRET assay) was performed on Days 8, 15 and 29 after the administration. Both chemicals increased Pig-a mutants among RBCs and RETs with dose dependency on all days examined. The mutant frequencies were higher among RETs compared with RBCs, indicating that the PIGRET assay could detect mutagenicity more sensitively than the RBC Pig-a assay after a single dose of test chemicals. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Pharmacokinetics of oral hydrocortisone - Results and implications from a randomized controlled trial.

    PubMed

    Werumeus Buning, Jorien; Touw, Daan J; Brummelman, Pauline; Dullaart, Robin P F; van den Berg, Gerrit; van der Klauw, Melanie M; Kamp, Jasper; Wolffenbuttel, Bruce H R; van Beek, André P

    2017-06-01

    This study aimed at comparing pharmacokinetics of two different doses of hydrocortisone (HC) in patients with secondary adrenal insufficiency (SAI). Forty-six patients with SAI participated in this randomized double-blind crossover study. Patients received two different doses of HC (0.2-0.3mg HC/kg body weight/day and 0.4-0.6mg HC/kg body weight/day). One- and two-compartment population models for plasma free cortisol, plasma total cortisol and salivary cortisol were parameterized. The individual pharmacokinetic parameters clearance (CL), volume of distribution (V d ), elimination half-life (t 1/2 ), maximum concentration (C max ), and area under the curve (AUC) were calculated. The one-compartment models gave a better description of the data compared to the two-compartment models. Weight-adjusted dosing reduced variability in cortisol exposure with comparable AUCs between weight groups. However, there was large inter-individual variation in CL and V d of plasma free cortisol, plasma total cortisol and salivary cortisol. As a consequence, AUC 24h varied more than 10 fold. Cortisol exposure was increased with the higher dose, but this was dose proportional only for free cortisol concentrations and not for total cortisol. Cortisol concentrations after a doubling of the dose were only dose proportional for free cortisol. HC pharmacokinetics can differ up to 10-fold inter-individually and individual adjustment of treatment doses may be necessary. Doubling of the HC dose in fast metabolizers (patients that showed relative low AUC and thus high clearance compared to other patients), does not result in significantly enhanced exposure during large parts of the day and these patients may need other management strategies. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Current smoking is an independent risk factor for new-onset diabetes mellitus during highdose glucocorticoid treatment.

    PubMed

    Sugiyama, Takao; Sugimoto, Toyohiko; Suzuki, Sawako; Sato, Yuta; Tanaka, Tomoaki; Tatsuno, Ichiro

    2015-08-01

    Although high-dose glucocorticoids have been reported to cause new-onset diabetes mellitus (glucocorticoid-induced diabetes mellitus), its risk factors have remained to be determined. We investigated the risk factors related to glucocorticoid-induced diabetes mellitus diagnosed within 2 months after the high-dose treatment (newly treated with an initial high dose of > 20 mg prednisolone (PSL) equivalent per day for at least more than 6 months) in collagen vascular diseases. A total of 2,631 patients with collagen vascular diseases was registered between 1986 and 2006 in the Chiba-Shimoshizu Rheumatic Cohort. We analyzed 681 patients newly treated with high-dose glucocorticoid who did not have diabetes mellitus and/or its previous diagnosis (age: 46.3 ± 16.7 years, PSL dose: 40.0 ± 14.1 mg/day). Glucocorticoid-induced diabetes mellitus was diagnosed by two or more glucose measurements in patients with fasting glycaemia ≥ 7 mmol/L and 120 minutes post-load glycaemia ≥ 11.1 mmol/L. Glucocorticoid-induced diabetes mellitus was observed in 26.3% of patients, and the glucocorticoid-induced diabetes mellitus group had higher age, higher BMI, lower rates of females and systemic lupus erythematosus, higher rates of smoking, alcohol use, and microscopic polyangiitis. Multivariate logistic regression analysis demonstrated that the risk of glucocorticoid-induced diabetes mellitus was independently higher in every 10-year increment of initial age with adjusted odds ratio (OR) 1.556 (95% confidence interval: 1.359 - 1.783), in every 1 kg/m2 increment of BMI with OR 1.062 (1.002 - 1.124), in current smoking with OR 1.664 (1.057 - 2.622), and in every 10 mg increment of initial dose of prednisolone with OR 1.250 (1.074 - 1.454). High-dose glucocorticoids caused diabetes mellitus with high prevalence within a short period, and current smokers should be considered at higher risk of glucocorticoidinduced diabetes mellitus in addition to age, BMI, and initial dose.

  9. Oral MSG administration alters hepatic expression of genes for lipid and nitrogen metabolism in suckling piglets.

    PubMed

    Chen, Gang; Zhang, Jun; Zhang, Yuzhe; Liao, Peng; Li, Tiejun; Chen, Lixiang; Yin, Yulong; Wang, Jinquan; Wu, Guoyao

    2014-01-01

    This experiment was conducted to investigate the effects of oral administration of monosodium glutamate (MSG) on expression of genes for hepatic lipid and nitrogen metabolism in piglets. A total of 24 newborn pigs were assigned randomly into one of four treatments (n = 6/group). The doses of oral MSG administration, given at 8:00 and 18:00 to sow-reared piglets between 0 and 21 days of age, were 0 (control), 0.06 (low dose), 0.5 (intermediate dose), and 1 (high dose) g/kg body weight/day. At the end of the 3-week treatment, serum concentrations of total protein and high-density lipoprotein cholesterol in the intermediate dose group were elevated than those in the control group (P < 0.05). Hepatic mRNA levels for fatty acid synthase, acetyl-coA carboxylase, insulin-like growth factor-1, glutamate-oxaloacetate transaminase, and glutamate-pyruvate transaminase were higher in the middle-dose group (P < 0.05), compared with the control group. MSG administration did not affect hepatic mRNA levels for hormone-sensitive lipase or carnitine palmitoyl transferase-1. We conclude that oral MSG administration alters hepatic expression of certain genes for lipid and nitrogen metabolism in suckling piglets.

  10. Sub-Chronic Safety Evaluation of Ayurvedic Immunostimulant Formulation ‘Immuforte’ in Rats in Reverse Pharmacology

    PubMed Central

    Dhumal, Rohit; Patil, Prakash; Selkar, Nilakash; Chawda, Mukesh; Vahlia, Mahesh; Vanage, Geeta

    2013-01-01

    Objective: The present study was undertaken to determine target organ safety of “Immuforte” to establish relationship between dose or exposure and response and also to identify potential parameters for monitoring adverse effects of “Immuforte” in clinical studies, if any. Materials and Methods: A total of 40 males and 40 females were randomly assigned to the four groups, namely group I (vehicle control; gum acacia), group II (120 mg/kg BW of Immuforte in gum acacia), group III (360 mg/kg BW of Immuforte in gum acacia), and group IV (600 mg/kg BW of Immuforte in gum acacia) consisting of 10 males and 10 females in each group. Additionally, a recovery group (600 mg/kg BW of Immuforte in gum acacia) containing 5 males and 5 females was included. Results: The results showed significant decrease in percent lymphocyte count of high and mid dose groups as compared to control group. The percent neutrophil counts in all the three treated groups of male and female rats were found to be significantly higher than that of control group (P < 0.05). In females MCV values in low dose and mid dose were significantly higher as compared to control (P < 0.05). The males from low dose group showed significant decrease in total serum protein, globulin, electrolytes, direct bilirubin, creatinine levels, whereas in mid dose group along with albumin, globulin. A significant decrease in AST and cholesterol was observed. In females, significant decrease was observed in total protein and globulin of low dose and mid dose of Immuforte-treated rats (P < 0.05). Though few hematological and biochemical parameters were different from control group, no does related response was observed and further, all these values were comparable with historical control data of the colony. Terminal body weight, organ weight, gross, and histopathology did not reveal any toxicity-related any adverse effects. Heavy metal analysis of the blood samples collected from terminally sacrificed animals did not show presence of heavy metals viz. lead (Pb), mercury (Hg), cadmium (Cd), and arsenic (As). Conclusion: The results of the present study demonstrated that Immuforte does not cause any observable toxicity at doses used in the study when administered for the period of 90 days and is safe for the human use and thus, Immuforte could be used safely for therapeutic use in humans. PMID:23833443

  11. Biological impact of low dose-rate simulated solar particle event radiation in vivo.

    PubMed

    Chang, P Y; Doppalapudi, R; Bakke, J; Wang, A; Menda, S; Davis, Z

    2010-08-01

    C57Bl6-lacZ animals were exposed to a range of low dose-rate simulated solar particle event (sSPE) radiation at the NASA-sponsored Research Laboratory (NSRL) at Brookhaven National Laboratory (BNL). Peripheral blood was harvested from animals from 1 to 12 days after total body irradiation (TBI) to quantify the level of circulating reticulocytes (RET) and micronucleated reticulocytes (MN-RET) as an early indicator of radiation-induced genotoxicity. Bone marrow lymphocytes and hippocampal tissues from each animal were collected at 12 days and up to two months, to evaluate dose-dependent late effects after sSPE exposure. Early hematopoietic changes show that the % RET was reduced up to 3 days in response to radiation exposure but recovered at 12 days postirradiation. The % MN-RET in peripheral blood was temporally regulated and dependant on the total accumulated dose. Total chromosome aberrations in lymphocytes increased linearly with dose within a week after radiation and remained significantly higher than the control values at 4 weeks after exposure. The level of aberrations in the irradiated animals returned to control levels by 8 weeks postirradiation. Measurements of chromosome 2 and 8 specific aberrations indicate that, consistent with conventional giemsa-staining methods, the level of aberrations is also not significantly higher than in control animals at 8 weeks postirradiation. The hippocampus was surveyed for differential transcriptional regulation of genes known to be associated with neurogenesis. Our results showed differential expression of neurotrophin and their associated receptor genes within 1 week after sSPE exposure. Progressive changes in the profile of expressed genes known to be involved in neurogenic signaling pathways were dependent on the sSPE dose. Our results to date suggest that radiation-induced changes in the hematopoietic system, i.e., chromosome aberrations in lymphocytes, are transient and do not persist past 4 weeks after radiation. On the other hand, alteration in the profile of genes known to be involved in neurotrophic functions in the hippocampal tissue appears to persist for up to 8 weeks after radiation exposure. Such temporal changes confirm that, although cytogenetic changes after a single dose of low-dose and low-dose-rate protons appear to be transient, the impact of this exposure is sufficient to lead to persistent dynamic changes in neuronal tissues long after the initial radiation exposure.

  12. A protocol for EBT3 radiochromic film dosimetry using reflection scanning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papaconstadopoulos, Pavlos, E-mail: pavpapac@gmail.com; Hegyi, Gyorgy; Seuntjens, Jan

    2014-12-15

    Purpose: To evaluate the performance of the EBT3 radiochromic film dosimetry system using reflection measurements and to suggest a calibration protocol for precise and accurate reflection film dosimetry. Methods: A set of 14 Gafchromic EBT3 film pieces were irradiated to various doses ranging from 0 to 8 Gy and subsequently scanned using both the reflection and transmission mode. Scanning resolution varied from 50 to 508 dpi (0.5–0.05 mm/pixel). Both the red and green color channels of scanned images were used to relate the film response to the dose. A sensitivity, uncertainty, and accuracy analysis was performed for all scanning modesmore » and color channels. The total uncertainty, along with the fitting and experimental uncertainty components, was identified and analyzed. A microscope resolution target was used to evaluate possible resolution losses under reflection scanning. The calibration range was optimized for reflection scanning in the low (<2 Gy) and high (>2 Gy) dose regions based on the reported results. Results: Reflection scanning using the red channel exhibited the highest sensitivity among all modes, being up to 150% higher than transmission mode in the red channel for the lowest dose level. Furthermore, there was no apparent loss in resolution between the two modes. However, higher uncertainties and reduced accuracy were observed for the red channel under reflection mode, especially at dose levels higher than 2 Gy. These uncertainties were mainly attributed to saturation effects which were translated in poor fitting results. By restricting the calibration to the 0–2 Gy dose range, the situation is reversed and the red reflection mode was superior to the transmission mode. For higher doses, the green channel in reflection mode presented comparable results to the red transmission. Conclusions: A two-color reflection scanning protocol can be suggested for EBT3 radiochromic film dosimetry using the red channel for doses less than 2 Gy and the green channel for higher doses. The precision and accuracy are significantly improved in the low dose region following such a protocol.« less

  13. β-blocker dosage and outcomes after acute coronary syndrome.

    PubMed

    Allen, Jason E; Knight, Stacey; McCubrey, Raymond O; Bair, Tami; Muhlestein, Joseph Brent; Goldberger, Jeffrey J; Anderson, Jeffrey L

    2017-02-01

    Although β-blockers increase survival in acute coronary syndrome (ACS) patients, the doses used in trials were higher than doses used in practice, and recent data do not support an advantage of higher doses. We hypothesized that rates of major adverse cardiac events (MACE), all-cause death, myocardial infarction, and stroke are equivalent for patients on low-dose and high-dose β-blocker. Patients admitted to Intermountain Healthcare with ACS and diagnosed with ≥70% coronary stenosis between 1994 and 2013 were studied (N = 7,834). We classified low dose as ≤25% and high dose as ≥50% of an equivalent daily dose of 200 mg of metoprolol. Multivariate analyses were used to test association between low-dose versus high-dose β-blocker dosage and MACE at 0-6 months and 6-24 months. A total of 5,287 ACS subjects were discharged on β-blockers (87% low dose, 12% high dose, and 1% intermediate dose). The 6-month MACE outcomes rates for the β-blocker dosage (low versus high) were not equivalent (P = .18) (hazard ratio [HR] = 0.76; 95% CI, 0.52-1.10). However, subjects on low-dose β-blocker therapy did have a significantly decreased risk of myocardial infarction for 0-6 months (HR = 0.53; 95% CI, 0.33-0.86). The rates of MACE events during the 6-24 months after presentation with ACS were equivalent for the 2 doses (P = .009; HR = 1.03 [95% CI, 0.70-1.50]). In ACS patients, rates of MACE for high-dose and low-dose β-blocker doses are similar. These findings question the importance of achieving a high dose of β-blocker in ACS patients and highlight the need for further investigation of this clinical question. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Hemopoietic Response to Low Dose-Rates of Ionizing Radiation Shows Stem Cell Tolerance and Adaptation

    PubMed Central

    Fliedner, Theodor M.; Graessle, Dieter H.; Meineke, Viktor; Feinendegen, Ludwig E.

    2012-01-01

    Chronic exposure of mammals to low dose-rates of ionizing radiation affects proliferating cell systems as a function of both dose-rate and the total dose accumulated. The lower the dose-rate the higher needs to be the total dose for a deterministic effect, i.e., tissue reaction to appear. Stem cells provide for proliferating, maturing and functional cells. Stem cells usually are particularly radiosensitive and damage to them may propagate to cause failure of functional cells. The paper revisits 1) medical histories with emphasis on the hemopoietic system of the victims of ten accidental chronic radiation exposures, 2) published hematological findings of long-term chronically gamma-irradiated rodents, and 3) such findings in dogs chronically exposed in large life-span studies. The data are consistent with the hypothesis that hemopoietic stem and early progenitor cells have the capacity to tolerate and adapt to being repetitively hit by energy deposition events. The data are compatible with the “injured stem cell hypothesis”, stating that radiation–injured stem cells, depending on dose-rate, may continue to deliver clones of functional cells that maintain homeostasis of hemopoiesis throughout life. Further studies perhaps on separated hemopoietic stem cells may unravel the molecular-biology mechanisms causing radiation tolerance and adaptation. PMID:23304110

  15. Higher rate of severe toxicities in obese patients receiving dose-dense (dd) chemotherapy according to unadjusted body surface area: results of the prospectively randomized GAIN study.

    PubMed

    Furlanetto, J; Eiermann, W; Marmé, F; Reimer, T; Reinisch, M; Schmatloch, S; Stickeler, E; Thomssen, C; Untch, M; Denkert, C; von Minckwitz, G; Lederer, B; Nekljudova, V; Weber, K; Loibl, S; Möbus, V

    2016-11-01

    In routine clinical practice, chemotherapy doses are frequently capped at a body surface area (BSA) of 2.0 m 2 or adjusted to an ideal weight for obese patients due to safety reasons. Between August 2004 and July 2008, a total of 3023 patients were enrolled in the GAIN study, a randomized phase III adjuvant trial, comparing two types of dose-dense (dd) regimen [epirubicin, docetaxel and cyclophosphamide (iddETC) versus epirubicin and cyclophosphamide (EC) followed by docetaxel (T) plus capecitabine (X)]. We retrospectively evaluated a total of 555 patients with a BMI of ≥30 for safety and outcome. Eighteen percent of all patients were obese: 31% of those received chemotherapy according to an unadjusted BSA. For the remaining patients, BSA was adjusted to ideal weight or was capped at 2.0 m 2 . A total of 15% of obese patients receiving full (unadjusted) dose of chemotherapy versus 6% of obese patients with an adjusted BSA experienced febrile neutropenia (P = 0.003) and 9% versus 3% high-grade thrombopenia (P = 0.002). Overall, 17% versus 10% had a thromboembolic event (P = 0.017), which was high grade in 13% versus 6%, respectively (P = 0.019), and 3% versus 0.3% high-grade hot flushes (P = 0.013). Dizziness (5% versus 11%; P = 0.016), diarrhea (19% versus 27%; P = 0.033) and an increase in serum creatinine (7% versus 14%; P = 0.019) were higher in the adjusted group. However, no differences in disease-free survival (DFS) and overall survival (OS) were observed between non-obese patients, obese patients receiving full-dose chemotherapy or according to an adjusted BSA [5-year DFS 81% (confidence interval 79% to 83%) versus 82% (75% to 87%) versus 81% (76% to 84%); P = 0.761; 5-year OS 90% (88% to 91%) versus 86% (80% to 91%) versus 88% (84% to 91%); P = 0.143]. Obese patients receiving dd chemotherapy according to their real BSA have a higher risk of developing severe toxicities without influencing survival. Therefore, a dose adjustment of intense dd chemotherapy should be carried out to avoid life-threatening complications. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  16. The Effect of Intra-articular Corticosteroids on Articular Cartilage

    PubMed Central

    Wernecke, Chloe; Braun, Hillary J.; Dragoo, Jason L.

    2015-01-01

    Background: Intra-articular (IA) corticosteroid therapy has been used for the treatment of inflammation and pain in the knee since the 1950s. Purpose: To review the current literature on the effects of IA corticosteroids on articular cartilage. Study Design: Systematic review. Methods: A MEDLINE and SCOPUS database search was performed, and studies were selected for basic science and clinical trial research on corticosteroids with direct outcome measures of cartilage health. Preliminary searches yielded 1929 articles, and final analysis includes 40 studies. Results: Methylprednisolone, dexamethasone, hydrocortisone, betamethasone, prednisolone, and triamcinolone were reported to display dose-dependent deleterious effects on cartilage morphology, histology, and viability in both in vitro and in vivo models. The beneficial animal in vivo effects of methylprednisolone, hydrocortisone, and triamcinolone occurred at low doses (usually <2-3 mg/dose or 8-12 mg/cumulative total dose in vivo), at which increased cell growth and recovery from damage was observed; the single human clinical trial indicated a beneficial effect of triamcinolone. However, at higher doses (>3 mg/dose or 18-24 mg/cumulative total dose in vivo), corticosteroids were associated with significant gross cartilage damage and chondrocyte toxicity. Dose and time dependency of corticosteroid chondrotoxicity was supported in the in vitro results, however, without clear dose thresholds. Conclusion: Corticosteroids have a time- and dose-dependent effect on articular cartilage, with beneficial effects occurring at low doses and durations and detrimental effects at high doses and durations. Clinically, beneficial effects are supported for IA administration, but the lowest efficacious dose should be used. PMID:26674652

  17. Adherence to phosphate binders in hemodialysis patients: prevalence and determinants.

    PubMed

    Van Camp, Yoleen P M; Vrijens, Bernard; Abraham, Ivo; Van Rompaey, Bart; Elseviers, Monique M

    2014-12-01

    Phosphate control is a crucial treatment goal in end-stage renal disease, but poor patient adherence to phosphate binder therapy remains a challenge. This study aimed to estimate the extent of phosphate binder adherence in hemodialysis patients and to identify potential determinants. Phosphate binder adherence was measured blindly in 135 hemodialysis patients for 2 months using the medication event monitoring system. Patient data, gathered at inclusion through medical records, ad hoc questionnaires and the short form (SF)-36 health survey, included: (1) demographics, (2) perceived side-effects, belief in benefit, self-reported adherence to the therapy, (3) knowledge about phosphate binder therapy, (4) social support, and (5) quality of life (SF-36). Phosphatemia data was collected from charts. 'Being adherent' was defined as missing <1 total daily dose/week and 'being totally adherent' as missing <1 total daily dose/week, every week. Mean age of patients was 67 years and 64 % of the sample was male. Over the 2 months, 78 % of the prescribed doses were taken. Every week, about half of patients were adherent. Over the entire 8-week period, 22 % of patients were totally adherent. Mean phosphatemia levels were 0.55 mg/dl lower in adherent than nonadherent patients (4.76 vs. 5.31 mg/dl). Determinants for being totally adherent were living with a partner, higher social support (both were interrelated) and higher physical quality of life. Experiencing intake-related inconvenience negatively affected adherence. The social support and quality of life physical score explained 26 % of the variance in adherence. Phosphate binder nonadherence remains a major problem. Interventions should aim, at least, to improve social support. With few associated factors found and yet low adherence, an individualized approach seems indicated.

  18. Immediate effects of 33 to 180 rad/min (60)Co exposure on performance and blood pressure in monkeys. Topical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruner, A.

    1976-09-01

    Four groups of monkeys received 1000 rads (60)Co at 33, 50, 75, or 180 rad/min wholebody irradiation while performing a delayed matching-to-sample task. Systematic dose rate effects were observed on performance and blood pressure within the initial 20 min postirradiation. The incidence and severity of performance decrement (PD) increased with higher dose rate. The appearance of postirradiation hypotension was systematically delayed and its rate of fall prolonged as dose rate was lower. The hypotension likewise appeared less deep with lower dose rate exposure. Based on the calculated cumulative dose absorbed at the time of symptom appearance two coactive thresholds weremore » proposed to exist: a total dose threshold of approximately 300 rads (midbody measurement), and a dose rate threshold of about 25 rad/min.« less

  19. Switch From Epoetin Beta to Darbepoetin Alfa Treatment of Anemia in Taiwanese Hemodialysis Patients: Dose Equivalence by Hemoglobin Stratification.

    PubMed

    Liao, Shang-Chih; Hung, Cheng-Chieh; Lee, Chien-Te; Lee, Chih-Hsiung; Lee, Chin-Chan; Lin, Chun-Liang; Sun, Chiao-Yin; Cheng, Ben-Chung; Yang, Chih-Chao; Wu, Chien-Hsing; Chen, Jin-Bor

    2016-08-01

    This multicenter study was designed to assess the hemoglobin (Hb) stability and conversion ratio of the switch from epoetin beta to darbepoetin alfa in Taiwanese hemodialysis (HD) patients. A total of 135 HD patients were enrolled and randomized with intravenous darbepoetin alfa or epoetin beta. The study duration was 24 weeks. Equivalent doses and conversion ratios were assessed with respect to Hb stratification: low Hb (≥8.0 g/dL to ≤10.0 g/dL) and high Hb (>10.0 g/dL to ≤11.0 g/dL). The results showed stable Hb levels in the study period. At week 24, the conversion ratio was higher for high Hb than low Hb (296.4 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa. vs. 277.2 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa). In conclusion, the conversion ratio in the present study was higher than 1 µg: 200 IU for darbepoetin alfa: epoetin for treating anemia in Taiwanese HD patients. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  20. Buprenorphine transdermal system utilization.

    PubMed

    Wallace, Laura; Kadakia, Aditi

    2017-01-01

    To evaluate utilization patterns in patients initiating buprenorphine transdermal system (BTDS), CIII, and estimate the proportion decreasing their total opioid dose over time. This retrospective cohort study used data from the Truven Health Analytics MarketScan® Commercial Claims and Encounters Database from 1 January 2011 through 31 December 2015. Eligible individuals were adults aged 18-64 years newly dispensed BTDS (index prescription) who had at least six months of insurance coverage prior to (baseline period) and following (study period) the index prescription. Back and neck pain was the most common pain condition in the study population (n = 31,533) and 88% were dispensed opioids in the baseline period. Nearly half (48%) received BTDS in a strength of 10 mcg/hour as their index prescription. Most (80%) patients prescribed BTDS had concomitant prescriptions for other opioids, chiefly immediate-release (IR) opioids (77%). During the baseline period, median opioid dose among patients prescribed opioids was 50 morphine-equivalent doses (MED), with 33% of patients using nonsteroidal anti-inflammatory drugs and 44% adjuvant analgesics. During the study period, BTDS use lasted a median 30 days and mean 100 days. Median dose of BTDS remained largely constant, and median dose of all opioids during continuous use of BTDS was 65.6 units MED. However, 24% of patients reduced total units MED from the baseline period (median mean dose, 74.5 units MED) until the end of the study period (42.8). Most patients initiating treatment with BTDS had a history of treatment with IR opioids. Though the average change in total opioid daily dose after patients were prescribed BTDS was modest, an important subpopulation of approximately one-quarter of patients were able to markedly reduce their total units MED compared with prior opioid therapy. BTDS should be investigated as an option to help patients step down from higher opioid doses.

  1. G-CSF plus preemptive plerixafor vs hyperfractionated CY plus G-CSF for autologous stem cell mobilization in multiple myeloma: effectiveness, safety and cost analysis.

    PubMed

    Antar, A; Otrock, Z K; Kharfan-Dabaja, M A; Ghaddara, H A; Kreidieh, N; Mahfouz, R; Bazarbachi, A

    2015-06-01

    The optimal stem cell mobilization regimen for patients with multiple myeloma (MM) remains undefined. We retrospectively compared our experience in hematopoietic cell mobilization in 83 MM patients using fractionated high-dose CY and G-CSF with G-CSF plus preemptive plerixafor. All patients in the CY group (n=56) received fractionated high-dose CY (5 g/m(2) divided into five doses of 1 g/m(2) every 3 h) with G-CSF. All patients in the plerixafor group (n=27) received G-CSF and plerixafor preemptively based on an established algorithm. Compared with plerixafor, CY use was associated with higher total CD34+ cell yield (7.5 × 10(6) vs 15.5 × 10(6) cells/kg, P=0.005). All patients in both groups yielded ⩾4 × 10(6) CD34+ cells/kg. Conversely, CY use was associated with high frequency of febrile neutropenia, blood and platelet transfusions need and hospitalizations. The average total cost of mobilization in Lebanon was slightly higher in the plerixafor group ($7886 vs $7536; P=0.16). Our data indicate robust stem cell mobilization in MM patients with either fractionated high-dose CY and G-CSF or G-CSF alone with preemptive plerixafor. The chemo-mobilization approach was associated with twofold stem cell yield, slightly lower cost but significantly increased toxicity.

  2. Comparison between a single dose of goserelin (depot) and multiple daily doses of leuprolide acetate for pituitary suppression in IVF treatment: a clinical endocrinological study of the ovarian response.

    PubMed

    Geber, Selmo; Sales, Liana; Sampaio, Marcos A C

    2002-07-01

    Compare the efficacy and safety of two different GnRHa, used for pituitary suppression in IVF cycles. A total of 292 patients using depot goserelin (Group 1) and 167 using daily leuprolide acetate (Group 2) were compared. Days required to achieve pituitary function suppression, duration of ovarian stimulation, total dose of HMG, number of aspirated follicles, number of oocytes retrieved, and presence of functional ovarian cyst were analyzed. The time taken to achieve downregulation was similar. The mean number of ampoules used for superovulation was higher in Group 1; however, this difference was observed only for patients >40 years old that started GnRHa in the follicular phase. There was no difference between the two groups in the duration of superovulation, in the number of follicles aspirated, and the number of oocytes retrieved. In the group of patients with >40 years the incidence of ovarian cysts was higher in Group 2. Both routes of GnRHa have similar effects for pituitary suppression and ovulation induction in assisted reproductive technology. Therefore the long-acting GnRHa is an excellent option, as only a single subcutaneous dose is necessary, decreasing the risk of the patient to forget its use and, most important, it does not interfere in the patient's quality of life.

  3. Biodosimetry estimate for high-LET irradiation.

    PubMed

    Wang, Z Z; Li, W J; Zhi, D J; Jing, X G; Wei, W; Gao, Q X; Liu, B

    2007-08-01

    The purpose of this paper is to prepare for an easy and reliable biodosimeter protocol for radiation accidents involving high-linear energy transfer (LET) exposure. Human peripheral blood lymphocytes were irradiated using carbon ions (LET: 34.6 keV microm(-1)), and the chromosome aberrations induced were analyzed using both a conventional colcemid block method and a calyculin A induced premature chromosome condensation (PCC) method. At a lower dose range (0-4 Gy), the measured dicentric (dics) and centric ring chromosomes (cRings) provided reasonable dose information. At higher doses (8 Gy), however, the frequency of dics and cRings was not suitable for dose estimation. Instead, we found that the number of Giemsa-stained drug-induced G2 prematurely condensed chromosomes (G2-PCC) can be used for dose estimation, since the total chromosome number (including fragments) was linearly correlated with radiation dose (r = 0.99). The ratio of the longest and the shortest chromosome length of the drug-induced G2-PCCs increased with radiation dose in a linear-quadratic manner (r = 0.96), which indicates that this ratio can also be used to estimate radiation doses. Obviously, it is easier to establish the dose response curve using the PCC technique than using the conventional metaphase chromosome method. It is assumed that combining the ratio of the longest and the shortest chromosome length with analysis of the total chromosome number might be a valuable tool for rapid and precise dose estimation for victims of radiation accidents.

  4. Effect of irradiated pork on physicochemical properties of meat emulsions

    NASA Astrophysics Data System (ADS)

    Choi, Yun-Sang; Sung, Jung-Min; Jeong, Tae-Jun; Hwang, Ko-Eun; Song, Dong-Heon; Ham, Youn-Kyung; Kim, Hyun-Wook; Kim, Young-Boong; Kim, Cheon-Jei

    2016-02-01

    The effect of pork irradiated with doses up to 10 kGy on meat emulsions formulated with carboxy methyl cellulose (CMC) was investigated. Raw pork was vacuums packaged at a thickness of 2.0 cm and irradiated by X-ray linear accelerator (15 kW, 5 MeV). The emulsion had higher lightness, myofibrillar protein solubility, total protein solubility, and apparent viscosity with increasing doses, whereas cooking loss, total expressible fluid separation, and hardness decreased. There were no significant differences in fat separation, sarcoplasmic protein solubility, springiness, and cohesiveness. Our results indicated that it is treatment by ionizing radiation which causes the effects the physicochemical properties of the final raw meat product.

  5. Radiation tolerant 1 micron CMOS technology

    NASA Astrophysics Data System (ADS)

    Crevel, P.; Rodde, K.

    1991-03-01

    Starting from a standard one micron Complementary Metal Oxide Semiconductor (CMOS) for high density, low power memory applications, the degree of radiation tolerance of the baseline process is evaluated. Implemented process modifications to improve latchup sensitivity under heavy ion irradiation as well as total dose effects without changing layout rules are described. By changing doping profiles in Metal Nitride Oxide Semiconductors (MNOS) and P-channel MOS (PMOS) device regions, it is possible to guarantee data sheet specification of a 64 K low power static RAM for total gamma dose up to 35 krad (Si) (and even higher values for the gate array family) without latch up for Linear Energy Transfer LET up to 115 MeV/(mg/cm squared).

  6. Interaction between physostigmine and soman on brain regional cholinesterase activity and /sup 3/H-physostigmine distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hallak, M.E.; Woodruff, E.; Giacobini, E.

    1986-03-05

    Physostigmine (Phy) concentrations (as radioactivity) were studied in various brain areas after /sup 3/H-Phy administration as a function of time. Five min after 500 ..mu..g/kg i.m., cortex (CX) and total brain showed similar concentrations (370 ng/g) which were 50-90% higher than those of other brain regions (striatum, hippocampus, and medulla oblongata). Soman did not affect Phy levels in whole brain after pretreatment with Phy (100 or 500 ..mu..g/kg), however, the regional distribution of Phy was altered by soman as was ChE inhibition. A significant increase in Phy concentration was seen in HC (22 and 45% at 5 and 30 min,more » respectively) and CX (21% at 30 min). ChE activity in total brain was 12, 30, and 24% (5, 15 and 30 min after soman administration) lower than after Phy alone. If the pretreatment dose of Phy was increased to 500 ..mu..g/kg /sup 3/H-Phy, ChE activity was further reduced to 4, 13 and 19%. This might indicate that higher doses of Phy provide more protection of the enzyme from soman than lower doses. The protective role of Phy seen in total brain was not consistent for all brain regions. Soman alone produced a 95% ChE inhibition and there were no differences in its effect between total brain or brain areas. Pretreatment of the rat with Phy produced a protective effect upon ChE activity up to 30 min. However, no protective effect on survival was observed.« less

  7. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    PubMed

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  8. Contribution of VKORC1 and CYP2C9 polymorphisms in the interethnic variability of warfarin dose in Malaysian populations.

    PubMed

    Gan, Gin Gin; Phipps, Maude E; Lee, Michael M T; Lu, Liang S; Subramaniam, Rajallectchumy Y; Bee, Ping C; Chang, Sean H

    2011-06-01

    Within the Asian populations, Indian patients had been reported to require higher warfarin dose compared with the Chinese and Malay patients, and this could not entirely be explained by cytochrome P450 (CYP)2C9 gene variants. Genetic variants of vitamin K epoxide oxidase reductase complex subunit 1 (VKORC1) has been well established as one of key determinants in the different responses of warfarin amongst patients. Adult patients who attended an anticoagulation clinic with stable INR were recruited. VKORC1 and CYP2C9 genotype were sequenced, and clinical characteristics were assessed. A total of 91 Malays, 96 Chinese, and 46 Indian patients were recruited. The mean age was 55 years and 51.5% were males. The mean dose of warfarin for all patients was 3.7 mg, and the mean daily dose of warfarin was significantly higher in Indians compared with the Chinese and Malay patients, 4.9 versus 3.5 and 3.3 mg, respectively (p < 0.001). VKORC1 GG genotype was more commonly seen in Indian patients. The mean warfarin dose in patients with GG genotype required a significant higher warfarin dose compared with those with AG and AA genotype (4.9 vs. 3.7 vs. 3.1 mg, respectively; p < 0.001). CYP2C9*2 and *3 is associated with a lower maintenance dose, 2.9 versus 3.7 mg in CYP2C9*1; p < 0.01. In multivariate analysis, age, ethnic groups, and genotypes had a significant influence on the required warfarin dose. In conclusion, VKORC1 and CYP2C9 polymorphism contribute to the difference dose requirement amongst the patients but other additional possible factors may play a role in the Indian race.

  9. Long-Term Results and Prognostic Factors of Fractionated Strontium-90 Eye Applicator for Pterygium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arruda Viani, Gustavo; Stefano, Eduardo Jose; Fendi, Ligia Issa de

    2008-11-15

    Purpose: To evaluate the long-term safety, effectiveness, and prognostic factors of fractionated postoperative {beta}-irradiation. Methods and Materials: Between 1993 and 2005, 623 patients with 737 pterygium lesions were treated with a strontium-90 eye applicator after surgical excision. The median follow-up period was 60 months (range, 6.7-139.5). Of the 737 lesions, 644 were primary and 93 were recurrences after surgical removal alone. Fractionated radiotherapy (RT) to a total dose of 35 Gy in five to seven fractions was used. Results: A total of 73 local pterygium recurrences (9.9%) were noted. Of the recurrent cases, 80% were noted within 3 years aftermore » treatment. The 5- and 10-year probability of local control was 90% and 88%, respectively. The multivariate analysis for all cases demonstrated that gender, age, total radiation dose, recurrent pterygia, and interval between surgery and RT affected the overall local control rate. Late toxicities that might have been associated with strontium-90 RT included scleromalacia (scleral thinning) in nine eyes, adhesion of the eyelids in eight, cataracts in six, and scleral ulcer in five eyes. Conclusion: Fractionated strontium-90 RT to a total dose of approximately 35 Gy in five to seven fractions results in a similar local control rate as higher doses in other series, with an acceptable complication rate.« less

  10. Study design and early result of a phase I study of SABR for early-stage glottic cancer.

    PubMed

    Yu, Tosol; Wee, Chan Woo; Choi, Noorie; Wu, Hong-Gyun; Kang, Hyun-Cheol; Park, Jong Min; Kim, Jung-In; Kim, Jin Ho; Kwon, Tack-Kyun; Chung, Eun-Jae

    2018-05-14

    Avoidance of organs at risk has become possible with advances in image-guided volumetric-modulated arc therapy (VMAT) techniques. This study was designed to evaluate the safety and feasibility of stereotactic ablative radiotherapy (SABR) for early stage glottic cancer. This report presents the preliminary result of the first and second dose level. Fraction size was increased from 3.5 gray (Gy) (total dose 59.5 Gy) to 9 Gy (total dose 45 Gy). Dose-limiting toxicities were defined as grade 3 or higher treatment-related toxicities. Voice outcome was assessed with electroglottography, and quality of life (QoL) was measured with the Head and Neck Cancer Inventory (HNCI). Seven patients received 59.5 Gy at 3.5 Gy per fraction as the first dose level, and five patients received 55 Gy at 5 Gy per fraction as the second dose level. None of the patients developed grade 3+ toxicity throughout a median follow-up of 17.5 months (range, 1.7-30.6 months). One patient in the second dose level recurred in the primary site at 4 months after radiotherapy (RT) and received total laryngectomy. The rest of participants were disease-free at locoregional and distant sites. Jitter, shimmer, mean phonation time, and noise-to-harmony ratio did not change significantly at 6 months after RT. HNCI scores between pretreatment and posttreatment were not significantly different (P = 0.221). This study revealed acceptable toxicity, voice outcome, and QoL in patients treated with hypofractionated VMAT of 3.5 Gy and 5 Gy per fraction. This phase I study is currently ongoing with a dose of 55 Gy in 11 fractions and 45 Gy in five fractions. 2b. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  11. High-dose anti-histamine use and risk factors in children with urticaria.

    PubMed

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-12-01

    The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p<0.0001). There was no difference between the two groups in terms of blood eosinophil and basophil counts, and serum total IgE levels (p>0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=-0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03-1.15]) and basopenia (OR: 6.77; CI 95%: [2.01-22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. The requirement of high-dose H1-antihistamines was higher with children's increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines.

  12. Hepatoprotective effect of Crocus sativus (saffron) petals extract against acetaminophen toxicity in male Wistar rats

    PubMed Central

    Omidi, Arash; Riahinia, Narges; Montazer Torbati, Mohammad Bagher; Behdani, Mohammad-Ali

    2014-01-01

    Objectives: Acetaminophen (APAP) toxicity is known to be common and potentially fatal. This study aims to investigate the protective effects of hydroalcoholic extract, remaining from Crocus sativus petals (CSP) against APAP-induced hepatotoxicity by measuring the blood parameters and studying the histopathology of liver in male rats. Materials and Methods: Wister rats (24) were randomly assigned into four groups including: I) healthy, receiving normal saline; II) Intoxicated, receiving only APAP (600 mg/kg); III) pre-treated with low dose of CSP (10 mg /kg) and receiving APAP (600 mg/kg); IV) pre-treated with high dose of CSP (20 mg/kg) and receiving APAP (600 mg/kg). Results: The APAP treatment resulted in higher levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), and bilirubin, along with lower total protein and albumin concentration than the control group. The administration of CSP with a dose of 20 mg/kg was found to result in lower levels of AST, ALT and bilirubin, with a significant higher concentration of total protein and albumin. The histopathological results regarding liver pathology, revealed sever conditions including cell swelling, severe inflammation and necrosis in APAP-exposed rats, which was quiet contrasting compared to the control group. The pre-treated rats with low doses of ‍CSP showed hydropic degeneration with mild necrosis in centrilobular areas of the liver, while the same subjects with high doses of ‍CSP appeared to have only mild hepatocyte degeneration. Conclusions: Doses of 20 mg/kg of CSP ameliorates APAP–induced acute liver injury in rats. It was concluded that the antioxidant property of CSP resulted in reducing the oxidative stress complications of toxic levels of APAP in intoxicated rats. PMID:25386395

  13. [Usefulness of Bolus Administration Using the FLEX Mode(Bolus Infusion Mode)for Baclofen Tolerance].

    PubMed

    Tanaka, Kazunori

    2017-02-01

    Intrathecal baclofen(ITB)is used to treat intractable spasticity of various etiologies and can provide better control of spasticity through the adjustment of the dose administered through the pump. However, in patients who develop tolerance to baclofen with the standard simple continuous mode, a sharp increase in dose becomes necessary, and spasticity can become harder to control. We investigated whether switching from the simple continuous mode to the bolus infusion mode was effective in controlling spasticity in patients with baclofen tolerance. We reported four patients undergoing ITB therapy at our facility who were considered to have developed baclofen tolerance. We observed the number of bolus infusions and total dose suitable for maintaining spasticity control after switching from the simple continuous mode to the bolus infusion mode. After switching to the bolus infusion mode, the total dose could be reduced in the short term; however, in the long term, the frequency of bolus infusions had to be increased to maintain spasticity control. Two years after changing to bolus infusion six times a day, the total dose was higher than that in the simple continuous mode for two of the four patients, and was the same level in the other two patients. Our four cases suggest that bolus infusion is effective in patients with baclofen tolerance during ITB therapy. Therefore, the conditions of bolus infusion should be further investigated.

  14. An accurate derivation of the air dose-rate and the deposition concentration distribution by aerial monitoring in a low level contaminated area

    NASA Astrophysics Data System (ADS)

    Nishizawa, Yukiyasu; Sugita, Takeshi; Sanada, Yukihisa; Torii, Tatsuo

    2015-04-01

    Since 2011, MEXT (Ministry of Education, Culture, Sports, Science and Technology, Japan) have been conducting aerial monitoring to investigate the distribution of radioactive cesium dispersed into the atmosphere after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP), Tokyo Electric Power Company. Distribution maps of the air dose-rate at 1 m above the ground and the radioactive cesium deposition concentration on the ground are prepared using spectrum obtained by aerial monitoring. The radioactive cesium deposition is derived from its dose rate, which is calculated by excluding the dose rate of the background radiation due to natural radionuclides from the air dose-rate at 1 m above the ground. The first step of the current method of calculating the dose rate due to natural radionuclides is calculate the ratio of the total count rate of areas where no radioactive cesium is detected and the count rate of regions with energy levels of 1,400 keV or higher (BG-Index). Next, calculate the air dose rate of radioactive cesium by multiplying the BG-Index and the integrated count rate of 1,400 keV or higher for the area where the radioactive cesium is distributed. In high dose-rate areas, however, the count rate of the 1,365-keV peak of Cs-134, though small, is included in the integrated count rate of 1,400 keV or higher, which could cause an overestimation of the air dose rate of natural radionuclides. We developed a method for accurately evaluating the distribution maps of natural air dose-rate by excluding the effect of radioactive cesium, even in contaminated areas, and obtained the accurate air dose-rate map attributed the radioactive cesium deposition on the ground. Furthermore, the natural dose-rate distribution throughout Japan has been obtained by this method.

  15. Pharmacokinetics of paracetamol and its metabolites in women at delivery and post‐partum

    PubMed Central

    Kulo, Aida; Peeters, Mariska Y.; Allegaert, Karel; Smits, Anne; de Hoon, Jan; Verbesselt, Rene; Lewi, Liesbeth; van de Velde, Marc; Knibbe, Catherijne A. J.

    2013-01-01

    Aim A recent report on intravenous (i.v.) paracetamol pharmacokinetics (PK) showed a higher total clearance in women at delivery compared with non‐pregnant women. To describe the paracetamol metabolic and elimination routes involved in this increase in clearance, we performed a population PK analysis in women at delivery and post‐partum in which the different pathways were considered. Methods Population PK parameters using non‐linear mixed effect modelling were estimated in a two‐period PK study in women to whom i.v. paracetamol (2 g loading dose followed by 1 g every 6 h up to 24 h) was administered immediately following Caesarean delivery and in a subgroup of the same women to whom single 2 g i.v.loading dose was administered 10–15 weeks post‐partum. Results Population PK analysis was performed based on 255 plasma and 71 urine samples collected in 39 women at delivery and in eight of these 39 women 12 weeks post‐partum. Total clearance was higher in women at delivery compared with 12th post‐partum week (21.1 vs. 11.7 l h−1) due to higher clearances to paracetamol glucuronide (11.6 vs. 4.76 l h−1), to oxidative metabolites (4.95 vs. 2.77 l h−1) and of unchanged paracetamol (1.15 vs. 0.75 l h−1). In contrast, there was no difference in clearance to paracetamol sulphate. Conclusion The increased total paracetamol clearance at delivery is caused by a disproportional increase in glucuronidation clearance and a proportional increase in clearance of unchanged paracetamol and in oxidation clearance, of which the latter may potentially limit further dose increase in this patient group. PMID:22845052

  16. High-dose transdermal nicotine replacement for tobacco cessation.

    PubMed

    Brokowski, Laurie; Chen, Jiahui; Tanner, Sara

    2014-04-15

    The safety and efficacy of high-dose transdermal nicotine-replacement therapy (NRT) for the treatment of tobacco-use cessation were reviewed. Transdermal nicotine doses of 7, 14, and 21 mg daily are approved by the Food and Drug Administration for use in tobacco cessation. However, studies have suggested that these doses are more adequate for people who smoke fewer than 20 cigarettes per day. A literature search was conducted to identify English-language studies that evaluated the use of transdermal nicotine doses of ≥42 mg daily. A total of 11 articles were identified, representing 10 separate trials. In terms of safety, the majority of the trials had no reports of serious adverse events related to transdermal NRT at doses of ≥42 mg daily. A dose-response relationship with adverse events occurred in most trials. In terms of efficacy, a numerically higher abstinence rate was achieved with high-dose transdermal NRT in all trials but 1. However, none of the studies showed significant differences in final abstinence rates at follow-up. Some reasons why statistical significance was not achieved in these trials may be related to the limitations of these trials, such as their small samples and the lack of a power calculation. A more robust trial is needed to support higher nicotine transdermal doses in tobacco cessation and to help elucidate which patient population would be most suitable for their use. The safety and efficacy of high-dose transdermal NRT for tobacco cessation have not been established in the medical literature.

  17. Successful pregnancy following very high-dose total body irradiation (1575 cGy) and bone marrow transplantation in a woman with acute myeloid leukemia.

    PubMed

    Wang, W S; Tzeng, C H; Hsieh, R K; Chiou, T J; Liu, J H; Yen, C C; Chen, P M

    1998-02-01

    A 22-year-old woman had a normal full-term delivery 6 years after a successful allogeneic bone marrow transplantation (BMT) for acute myeloid leukemia (AML). Conditioning therapy consisted of cyclophosphamide (120 mg/kg) and total body irradiation (TBI) to a total of 1575 cGy in seven fractions (225 cGy x 7, at a dose rate of 3.5 cGy/min). Graft-versus-host disease prophylaxis was with methotrexate and cyclosporin A. Grade I acute GVHD developed after BMT but there was no chronic GVHD. She became amenorrhoeic after BMT and serial gonadal testing indicated hypergonadotrophic hypogonadism. She became pregnant and delivered a full-term, healthy baby 6 years after BMT. Successful pregnancy after TBI of more than 1200 cGy is extremely rare. This case, to the best of our knowledge, is the second patient who received a higher dose of TBI (1575 cGy) to have a successful pregnancy. This and previous reports indicate that normal pregnancy is possible after BMT with TBI in excess of 1200 cGy.

  18. Gamma radiation combined with cinnamon oil to maintain fish quality

    NASA Astrophysics Data System (ADS)

    Lyu, Fei; Zhang, Jing; Wei, Qianqian; Gao, Fei; Ding, Yuting; Liu, Shulai

    2017-12-01

    Effects of gamma radiation combined with cinnamon oil on quality of Northern Snakehead fish fillets were observed during storage at 4 °C. Fish fillets were treated with 1-5 kGy gamma radiation, 0.05-0.5% cinnamon oil or the combination of radiation and cinnamon oil. The antimicrobial activity increased with radiation dose and cinnamon oil concentration. During storage, the combination of 1 kGy radiation and 0.5% cinnamon oil displayed better inhibiting activities on aerobic plate counts, total volatile basic nitrogen, thiobarbituric acid reaction substances than 1 kGy radiation or 0.5% cinnamon oil used alone. Moreover, the combination could arrive at the similar inhibiting activities of cinnamon oil with higher concentration of 0.5% or radiation with higher dose of 5 kGy. Thus, the combination could decrease the radiation dose and cinnamon oil concentration without decreasing the effect of them on maintaining fish quality.

  19. Maximizing Tumor Immunity With Fractionated Radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaue, Doerthe, E-mail: dschaue@mednet.ucla.edu; Ratikan, Josephine A.; Iwamoto, Keisuke S.

    Purpose: Technologic advances have led to increased clinical use of higher-sized fractions of radiation dose and higher total doses. How these modify the pathways involved in tumor cell death, normal tissue response, and signaling to the immune system has been inadequately explored. Here we ask how radiation dose and fraction size affect antitumor immunity, the suppression thereof, and how this might relate to tumor control. Methods and Materials: Mice bearing B16-OVA murine melanoma were treated with up to 15 Gy radiation given in various-size fractions, and tumor growth followed. The tumor-specific immune response in the spleen was assessed by interferon-{gamma}more » enzyme-linked immunospot (ELISPOT) assay with ovalbumin (OVA) as the surrogate tumor antigen and the contribution of regulatory T cells (Tregs) determined by the proportion of CD4{sup +}CD25{sup hi}Foxp3{sup +} T cells. Results: After single doses, tumor control increased with the size of radiation dose, as did the number of tumor-reactive T cells. This was offset at the highest dose by an increase in Treg representation. Fractionated treatment with medium-size radiation doses of 7.5 Gy/fraction gave the best tumor control and tumor immunity while maintaining low Treg numbers. Conclusions: Radiation can be an immune adjuvant, but the response varies with the size of dose per fraction. The ultimate challenge is to optimally integrate cancer immunotherapy into radiation therapy.« less

  20. Internal exposure to (210)Po and (40)K from ingestion of cooked daily foodstuffs for adults in Japanese cities.

    PubMed

    Sugiyama, Hideo; Terada, Hiroshi; Isomura, Kimio; Iijima, Ikuyo; Kobayashi, Jun; Kitamura, Kiyoshi

    2009-10-01

    The isotope (210)Po was suspected of being involved in the death of a former Russian intelligence agent in 2006 in the UK. Although human exposure to this natural radionuclide in foods is estimated to be high, few studies are available. UNSCEAR Report 2000 does not contain data on (210)Po concentrations of foodstuffs in Japan. We analyzed samples of the everyday Japanese diet cooked with foodstuffs purchased at supermarkets in 7 major domestic cities in 2007-2008. (210)Po was quantified by alpha spectrometry and natural radionuclides such as (40)K by gamma spectrometry. The daily intake and committed effective dose of (210)Po, (40)K, and other natural radionuclides for Japanese adults were calculated. Daily intake was 0.34-1.84 (mean +/- sigma : 0.66 +/- 0.53) and 68.5-94.2 (81.5 +/- 8.5) Bq/d and the committed effective dose was 0.15-0.81 (0.29 +/- 0.24) and 0.16-0.21 (0.18 +/- 0.02) mSv for (210)Po and (40)K, respectively, comprising a high percentage of the total exposure. The total of the mean committed effective dose for the two nuclides (0.47 mSv) was higher than the annual effective dose from ingestion of foods reported by UNSCEAR 2000 (0.29 mSv). The mean committed effective dose of (40)K in the 7 major Japanese cities was comparable to the global average (0.17 mSv). The dietary exposure of Japanese adults can be characterized by a higher (210)Po contribution than in other countries. Of the total daily dietary (210)Po exposure (13 food categories excluding water) for adults in Yokohama, about 70% was from fish/shellfish and 20% from vegetables/mushrooms/seaweeds, reflecting preferences of Japanese to eat a considerable amount of fish/shellfish containing high (210)Po concentrations.

  1. Hepatic glutathione metabolism and lipid peroxidation in response to excess dietary selenomethionine and selenite in mallard ducklings

    USGS Publications Warehouse

    Hoffman, D.J.; Heinz, G.H.; Krynitsky, A.J.

    1989-01-01

    Selenium from selenomethionine accumulated in a dose-dependent manner in the liver, resulting in a decrease in hepatic-reduced glutathione with a corresponding decrease in total hepatic thiols. There was a dose-dependent increase in the oxidized to reduced glutathione ratio, and an increase in lipid peroxidation. These findings indicate that Se in the diet at 10 ppm and higher causes significant sublethal alterations in mallard ducklings, and 20-40 ppm causes significant hepatotoxicity.

  2. The Effects of ELDRS at Ultra-Low Dose Rates

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; Forney, James; Carts, Martin; Phan, Anthony; Pease, Ronald; Kruckmeyer, Kirby; Cox, Stephen; LaBel, Kenneth; Burns, Samuel; Albarian, Rafi; hide

    2011-01-01

    We present results on the effects on ELDRS at dose rates of 10, 5, 1, and 0.5 mrad(Si)/s for a variety of radiation hardened and commercial devices. We observed low dose rate enhancement below 10 mrad(Si)/s in several different parts. The magnitudes of the dose rate effects vary. The TL750L, a commercial voltage regulator, showed dose rate dependence in the functional failures, with initial failures occurring after 10 krad(Si) for the parts irradiated at 0.5 mrad(Si)/s. The RH1021 showed an increase in low dose rate enhancement by 2x at 5 mrad(Si)/s relative to 8 mrad(Si)/s and high dose rate, and parametric failure after 100 krad(Si). Additionally the ELDRS-free devices, such as the LM158 and LM117, showed evidence of dose rate sensitivity in parametric degradations. Several other parts also displayed dose rate enhancement, with relatively lower degradations up to approx.15 to 20 krad(Si). The magnitudes of the dose rate enhancement will likely increase in significance at higher total dose levels.

  3. A Pharmacovigilance Study in First Episode of Psychosis: Psychopharmacological Interventions and Safety Profiles in the PEPs Project

    PubMed Central

    Bioque, Miquel; Llerena, Adrián; Cabrera, Bibiana; Mezquida, Gisela; Lobo, Antonio; González-Pinto, Ana; Díaz-Caneja, Covadonga M.; Corripio, Iluminada; Aguilar, Eduardo J.; Bulbena, Antoni; Castro-Fornieles, Josefina; Vieta, Eduard; Lafuente, Amàlia; Mas, Sergi; Parellada, Mara; Saiz-Ruiz, Jerónimo; Cuesta, Manuel J.

    2016-01-01

    Background: The characterization of the first episode of psychosis and how it should be treated are principal issues in actual research. Realistic, naturalistic studies are necessary to represent the entire population of first episode of psychosis attended in daily practice. Methods: Sixteen participating centers from the PEPs project recruited 335 first episode of psychosis patients, aged 7 to 35 years. This article describes and discusses the psychopharmacological interventions and safety profiles at baseline and during a 60-day pharmacovigilance period. Results: The majority of first episode of psychosis patients received a second-generation antipsychotic (96.3%), orally (95%), and in adjusted doses according to the product specifications (87.2%). A total of 24% were receiving an antipsychotic polytherapy pattern at baseline, frequently associated with lower or higher doses of antipsychotics than the recommended ones. Eight patients were taking clozapine, all in monotherapy. Males received higher doses of antipsychotic (P=.043). A total of 5.2% of the patients were being treated with long-acting injectable antipsychotics; 12.2% of the patients received anticholinergic drugs, 12.2% antidepressants, and 13.7% mood stabilizers, while almost 40% received benzodiazepines; and 35.52% reported at least one adverse drug reaction during the pharmacovigilance period, more frequently associated with higher antipsychotic doses and antipsychotic polytherapy (85.2% vs 45.5%, P<.001). Conclusions: These data indicate that the overall pharmacologic prescription for treating a first episode of psychosis in Spain follows the clinical practice guideline recommendations, and, together with security issues, support future research of determinate pharmacological strategies for the treatment of early phases of psychosis, such as the role of clozapine, long-acting injectable antipsychotics, antipsychotic combination, and the use of benzodiazepines. PMID:26506856

  4. Propagation of an Avirulent Turkey Hemorrhagic Enteritis Virus Isolate in Chickens.

    PubMed

    Gerber, Priscilla F; Hossain, Mohammad F; Reynolds, Paul; Hoang, Phuong; Burgess, Susan K; Renz, Katrin; McMillan, Mary; Katz, Margaret E; Walkden-Brown, Stephen W

    2018-03-01

    A series of studies were undertaken to optimize the propagation of hemorrhagic enteritis virus (HEV) in specific-pathogen-free (SPF) chickens. A total of 562 SPF chickens were orally inoculated with an Australian avirulent HEV isolate of turkey origin at 9, 14, 21, or 28 days of age with 5, 6, 7, or 8 log  10 genomic copies (GC), while 102 chickens served as uninfected controls. No clinical signs were observed in infected chickens. There was an inoculum-dose-dependent increase in the relative spleen and liver weight ( P < 0.01). Relative spleen weight 7 days post-HEV inoculation was up to 85% higher in chickens that were inoculated with 6 to 7 GC compared with controls, with no further increase at higher doses. Relative liver weight increased up to 14% in chickens inoculated with 6 GC, with no further increase. Birds inoculated with a 7 GC dose had a higher frequency of HEV DNA-positive birds (77% to 86%) than birds inoculated with lower doses (33% to 59%; P < 0.01). The most efficient dose for live passage propagation was 7 GC inoculated in 9-to-14-day-old birds, yielding an infection rate of 81%. Livers and spleens from infected birds at all doses were processed to produce a putative vaccine with a final GC recovery in the vaccine material of 8.6 GC/bird. In summary, HEV of turkey origin can be readily propagated in SPF chickens, and conditions to maximize viral retrieval were established.

  5. Intravenous Iron Therapy in Patients with Iron Deficiency Anemia: Dosing Considerations

    PubMed Central

    Myers, Jennifer; Goodnough, Lawrence Tim

    2015-01-01

    Objective. To provide clinicians with evidence-based guidance for iron therapy dosing in patients with iron deficiency anemia (IDA), we conducted a study examining the benefits of a higher cumulative dose of intravenous (IV) iron than what is typically administered. Methods. We first individually analyzed 5 clinical studies, averaging the total iron deficit across all patients utilizing a modified Ganzoni formula; we then similarly analyzed 2 larger clinical studies. For the second of the larger studies (Study 7), we also compared the efficacy and retreatment requirements of a cumulative dose of 1500 mg ferric carboxymaltose (FCM) to 1000 mg iron sucrose (IS). Results. The average iron deficit was calculated to be 1531 mg for patients in Studies 1–5 and 1392 mg for patients in Studies 6-7. The percentage of patients who were retreated with IV iron between Days 56 and 90 was significantly (p < 0.001) lower (5.6%) in the 1500 mg group, compared to the 1000 mg group (11.1%). Conclusions. Our data suggests that a total cumulative dose of 1000 mg of IV iron may be insufficient for iron repletion in a majority of patients with IDA and a dose of 1500 mg is closer to the actual iron deficit in these patients. PMID:26257955

  6. Efficacy of Low-dose (2 millicurie) versus Standard-dose (4 millicurie) Radioiodine Treatment for Cats with Mild-to-Moderate Hyperthyroidism.

    PubMed

    Lucy, J M; Peterson, M E; Randolph, J F; Scrivani, P V; Rishniw, M; Davignon, D L; Thompson, M S; Scarlett, J M

    2017-03-01

    Radioiodine ( 131 I) is effective treatment for hyperthyroidism in cats, but optimal dose to restore euthyroidism without inducing hypothyroidism is unclear. Treatment-induced hypothyroidism can lead to azotemia and reduced duration of survival. To compare efficacy and short-term outcomes of low-dose 131 I versus higher, standard-dose 131 I as treatment for hyperthyroidism. A total of 189 client-owned cats undergoing 131 I treatment for mild-to-moderate hyperthyroidism (serum T 4 ≥ 4.0 μg/dL and <13.0 μg/dL). Prospective, nonrandomized, cohort study comparing treatment with either low-dose (2 mCi, n = 150) or standard-dose (4 mCi, n = 39) 131 I. Serum T 4 , thyroid-stimulating hormone (TSH), and creatinine concentrations were measured after 1, 3, and 6 months to determine persistent hyperthyroidism, overt hypothyroidism (low T 4 , high TSH), subclinical hypothyroidism (normal T 4 , high TSH), and azotemia. There was no significant difference in prevalence of cats with persistent hyperthyroidism between standard- and low-dose treatment groups at 3 (0% versus 5.3%; P = .34) and 6 (0% versus 3.3%; P = .51) months. Overt (18% versus 1%; P = .0005) or subclinical (46% versus 21%; P = .004) hypothyroidism was more common in cats at 6 months after standard-dose 131 I. No difference in incidence of azotemia existed between groups, but cats treated with standard-dose 131 I had higher creatinine concentrations (P < .05) and higher percent rises in creatinine (P < .0001). Low-dose 131 I is safe and effective for cats with mild-to-moderate hyperthyroidism, as evidenced by a cure rate of >95% with reduced frequency of iatrogenic hypothyroidism and azotemia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Characterization of the disposition of fostamatinib in Japanese subjects including pharmacokinetic assessment in dry blood spots: results from two phase I clinical studies.

    PubMed

    Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael

    2016-01-01

    The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (<0.1 %) R406 was excreted in urine. Fostamatinib was well tolerated at all doses. Fostamatinib pharmacokinetics following single- and multiple-dose administration was approximately dose proportional at all doses ≤150 mg and greater than dose proportional at 200 mg in Japanese subjects. Japanese subjects administered fostamatinib 150 mg had higher exposure than white subjects. R406 could be measured in DBS samples and distributed into red blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.

  8. Efficiency of early, single-dose probiotic administration methods on performance, small intestinal morphology, blood biochemistry, and immune response of Japanese quail.

    PubMed

    Seifi, Kazem; Karimi Torshizi, Mohammad Amir; Rahimi, Shaban; Kazemifard, Mohammad

    2017-07-01

    The aim of the present study was to investigate the efficacy of early probiotics (single dose) administered in different ways, on quails' performance, small intestine morphology, blood biochemistry, and immune response. In total, 192 day-old chicks were used in one of the following experimental groups before being transferred to a raising room: 1) Control (no probiotic administered), 2) oral gavage, 3) spray, and 4) vent lip. Four replicates of 12 chicks per cage were considered for each treatment and birds were raised up to 35 d in the same conditions. Probiotic treated birds had higher d 1 to 35 feed intake than the control group (P < 0.05). In addition, oral-gavaged birds had a higher body weight gain as compared to the control (P < 0.05). The values of duodenum length and villus height of the oral group and ileum length and villus height of the vent lip group were greater than that of the control (P < 0.01). Regardless of the method of administration, probiotics resulted in deeper crypts and in a higher number of goblet cells in the duodenum and ileum as compared to the control (P < 0.01). The administration of probiotics resulted in increased plasma uric acid (P < 0.05), glucose, and total protein (P < 0.01). The concentration of hemoglobin was slightly higher in probiotic-supplemented groups. While a decreased concentration of triglyceride was observed in vent-lip probiotic-administered birds compared to control (P < 0.05), the concentration of cholesterol was not significantly affected by treatments (P > 0.01). None of the immune-related parameters were affected by the probiotic (P > 0.05). Single dose usage of probiotics exerts its beneficial effects on quails' body weight gain, feed intake and mortality in 1 to 35 d period, regardless of the route of administration. This work generally supports the efficacy of single-dose usage of probiotics and suggests the spray of probiotics as an early, single-dose administration method. © 2017 Poultry Science Association Inc.

  9. A prospective case control comparison of the ZeroGravity system versus a standard lead apron as radiation protection strategy in neuroendovascular procedures.

    PubMed

    Haussen, Diogo C; Van Der Bom, Imramsjah Martijn John; Nogueira, Raul G

    2016-10-01

    We aimed to compare the performance of the ZeroGravity (ZG) system (radiation protection system composed by a suspended lead suit) against the use of standard protection (lead apron (LA), thyroid shield, lead eyeglasses, table skirts, and ceiling suspended shield) in neuroangiography procedures. Radiation exposure data were prospectively collected in consecutive neuroendovascular procedures between December 2014 and February 2015. Operator No 1 was assigned to the use of an LA (plus lead glasses, thyroid shield, and a 1 mm hanging shield at the groin) while operator No 2 utilized the ZG system. Dosimeters were used to measure peak skin dose for the head, thyroid, and left foot. The two operators performed a total of 122 procedures during the study period. The ZG operator was more commonly the primary operator compared with the LA operator (85% vs 71%; p=0.04). The mean anterior-posterior (AP), lateral, and cumulative dose area product (DAP) radiation exposure as well as the mean fluoroscopy time were not statistically different between the operators' cases. The peak skin dose to the head of the operator with LA was 2.1 times higher (3380 vs 1600 μSv), while the thyroid was 13.9 (4460 vs 320 μSv), the mediastinum infinitely (520 vs 0 μSv), and the foot 3.3 times higher (4870 vs 1470 μSv) compared with the ZG operator, leading to an overall accumulated dose 4 times higher. The ratio of cumulative operator received dose/total cumulative DAP was 2.5 higher on the LA operator. The ZG radiation protection system leads to substantially lower radiation exposure to the operator in neurointerventional procedures. However, substantial exposure may still occur at the level of the lens and thyroid to justify additional protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. The H3 antagonist ABT-288 is tolerated at significantly higher exposures in subjects with schizophrenia than in healthy volunteers.

    PubMed

    Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Gertsik, Lev; Dutta, Sandeep

    2014-06-01

    ABT-288 is a potent and selective H3 receptor antagonist with procognitive effects in several preclinical models. In previous studies, 3 mg once daily was the maximal tolerated dose in healthy volunteers. This study characterized the safety, tolerability and pharmacokinetics of ABT-288 in stable subjects with schizophrenia. This was a randomized, double-blind, placebo-controlled, dose-escalating study of ABT-288 (10 dose levels, from 1 to 60 mg once daily for 14 days) in stable subjects with schizophrenia treated with an atypical antipsychotic. In each dose group, five to seven and two to three participants were assigned to ABT-288 and placebo, respectively. Of the 67 participants enrolled, nine participants (on ABT-288) were prematurely discontinued, in seven of these due to adverse events. ABT-288 was generally safe and tolerated at doses up to 45 mg once daily. The most common adverse events, in decreasing frequency (from 31 to 5%), were abnormal dreams, headache, insomnia, dizziness, somnolence, dysgeusia, dry mouth, psychotic disorder, parosmia and tachycardia. Adverse events causing early termination were psychotic events (four) and increased creatine phosphokinase, pyrexia and insomnia (one each). The half-life of ABT-288 ranged from 28 to 51 h, and steady state was achieved by day 12 of dosing. At comparable multiple doses, ABT-288 exposure in subjects with schizophrenia was 45% lower than that previously observed in healthy subjects. At trough, ABT-288 cerebrospinal fluid concentrations were 40% of the total plasma concentrations. ABT-288 was tolerated at a 15-fold higher dose and 12-fold higher exposures in subjects with schizophrenia than previously observed in healthy volunteers. The greater ABT-288 tolerability was not due to limited brain uptake. © 2013 The British Pharmacological Society.

  11. An assessment of radiation doses at an educational institution 57.8 km away from the Fukushima Daiichi nuclear power plant 1 month after the nuclear accident.

    PubMed

    Tsuji, Masayoshi; Kanda, Hideyuki; Kakamu, Takeyasu; Kobayashi, Daisuke; Miyake, Masao; Hayakawa, Takehito; Mori, Yayoi; Okochi, Toshiyasu; Hazama, Akihiro; Fukushima, Tetsuhito

    2012-03-01

    On 11 March 2011, the Great East Japan Earthquake occurred. Due to this earthquake and subsequent tsunami, malfunctions occurred at the Fukushima Daiichi nuclear power plant. Radioactive material even reached the investigated educational institution despite being 57.8 km away from the power station. With the goal of ensuring the safety of our students, we decided to carry out a risk assessment of the premises of this educational institution by measuring radiation doses at certain locations, making it possible to calculate estimated radiation accumulation. Systematic sampling was carried out at measurement points spaced at regular intervals for a total of 24 indoor and outdoor areas, with 137 measurements at heights of 1 cm and 100 cm above the ground surface. Radiation survey meters were used to measure environmental radiation doses. Radiation dose rates and count rates were higher outdoors than indoors, and higher 1 cm above the ground surface than at 100 cm. Radiation doses 1 cm above the ground surface were higher on grass and moss than on asphalt and soil. The estimated radiation exposure for a student spending an average of 11 h on site at this educational institution was 9.80 μSv. Environmental radiation doses at our educational institution 57.8 km away from the Fukushima Daiichi nuclear power plant 1 month after the accident were lower than the national regulation dose for schools (3.8 μSv/h) at most points. Differences in radiation doses depending on outdoor surface properties are important to note for risk reduction.

  12. Evaluation of Emergency Department Management of Opioid-Tolerant Cancer Patients With Acute Pain.

    PubMed

    Patel, Pina M; Goodman, Lauren F; Knepel, Sheri A; Miller, Charles C; Azimi, Asma; Phillips, Gary; Gustin, Jillian L; Hartman, Amber

    2017-10-01

    There are no previously published studies examining opioid doses administered to opioid-tolerant cancer patients during emergency department (ED) encounters. To determine if opioid-tolerant cancer patients presenting with acute pain exacerbations receive adequate initial doses of as needed (PRN) opioids during ED encounters based on home oral morphine equivalent (OME) use. We performed a retrospective cohort study of opioid-tolerant cancer patients who received opioids in our ED over a two-year period. The percentage of patients who received an adequate initial dose of PRN opioid (defined as ≥10% of total 24-hour ambulatory OME) was evaluated. Logistic regression was used to establish the relationship between 24-hour ambulatory OME and initial ED OME to assess whether higher home usage was associated with higher likelihood of being undertreated. Out of 216 patients, 61.1% of patients received an adequate initial PRN dose of opioids in the ED. Of patients taking <200 OMEs per day at home, 77.4% received an adequate initial dose; however, only 3.2% of patients taking >400 OMEs per day at home received an adequate dose. Patients with ambulatory 24-hour OME greater than 400 had 99% lower odds of receiving an adequate initial dose of PRN opioid in the ED compared to patients with ambulatory 24-hour OME less than 100 (OR <0.01, CI 0.00-0.02, P < 0.001). Patients with daily home use less than 200 OMEs generally received adequate initial PRN opioid doses during their ED visit. However, patients with higher home opioid usage were at increased likelihood of being undertreated. Copyright © 2017 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  13. Higher-Than-Conventional Radiation Doses in Localized Prostate Cancer Treatment: A Meta-analysis of Randomized, Controlled Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viani, Gustavo Arruda; Stefano, Eduardo Jose; Afonso, Sergio Luis

    2009-08-01

    Purpose: To determine in a meta-analysis whether the outcomes in men with localized prostate cancer treated with high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT), by quantifying the effect of the total dose of radiotherapy on biochemical control (BC). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing HDRT with CDRT for localized prostate cancer. To evaluate the dose-response relationship, we conducted a meta-regression analysis of BC ratios by means of weighted linear regression. Results:more » Seven RCTs with a total patient population of 2812 were identified that met the study criteria. Pooled results from these RCTs showed a significant reduction in the incidence of biochemical failure in those patients with prostate cancer treated with HDRT (p < 0.0001). However, there was no difference in the mortality rate (p = 0.38) and specific prostate cancer mortality rates (p = 0.45) between the groups receiving HDRT and CDRT. However, there were more cases of late Grade >2 gastrointestinal toxicity after HDRT than after CDRT. In the subgroup analysis, patients classified as being at low (p = 0.007), intermediate (p < 0.0001), and high risk (p < 0.0001) of biochemical failure all showed a benefit from HDRT. The meta-regression analysis also detected a linear correlation between the total dose of radiotherapy and biochemical failure (BC = -67.3 + [1.8 x radiotherapy total dose in Gy]; p = 0.04). Conclusions: Our meta-analysis showed that HDRT is superior to CDRT in preventing biochemical failure in low-, intermediate-, and high-risk prostate cancer patients, suggesting that this should be offered as a treatment for all patients, regardless of their risk status.« less

  14. Glyburide transport across the human placenta.

    PubMed

    Schwartz, Rachelle A; Rosenn, Barak; Aleksa, Katarina; Koren, Gideon

    2015-03-01

    To estimate the magnitude of transplacental transfer of glyburide in women with gestational diabetes mellitus (GDM). A prospective, observational study was conducted on women with GDM on glyburide therapy. On delivery admission, the glyburide dose and time of last dose were recorded. Immediately postdelivery, maternal and umbilical venous blood samples were obtained and the concentrations of glyburide were determined by high-performance liquid chromatography-mass spectrometry with a limit of detection of 0.25 ng/mL. Nineteen patient dyads were analyzed. The mean total daily maternal glyburide dose was 6.6±6.3 mg per day and the mean time between last dose and sampling was 13.3±6.5 hours. The mean maternal serum glyburide level at birth was 15.4±20.8 ng/mL, whereas the mean umbilical glyburide level was 7.5±8.2 ng/mL, which showed a statistical correlation (r=0.72, P<.01). There were statistically significant relationships between total maternal glyburide dose (1.25-20 mg per day) and maternal glyburide levels (0.93-70.71 ng/mL; r=0.46, P≤.01) and between total maternal glyburide dose and umbilical glyburide levels (0.95-32.41 ng/mL; r=0.43, P≤.01) However, we observed wide variability in maternal and umbilical glyburide levels at both extremes of the total glyburide dose. Seventy-nine percent of cord samples (15/19) had glyburide levels less than 10 ng/mL (the limit of detection reported in earlier studies) and 37% (7/19) were higher than the corresponding maternal samples. Transplacental transfer of glyburide is highly variable among patients, corroborating ex vivo placental perfusion studies showing a transport-mediated glyburide efflux from the fetal to the maternal circulation. In most neonates (79%), glyburide levels were below 10 ng/mL. III.

  15. Postoperative hypofractionated stereotactic brain radiation (HSRT) for resected brain metastases: improved local control with higher BED10.

    PubMed

    Kumar, Aryavarta M S; Miller, Jonathan; Hoffer, Seth A; Mansur, David B; Coffey, Michael; Lo, Simon S; Sloan, Andrew E; Machtay, Mitchell

    2018-05-10

    HSRT directed to large surgical beds in patients with resected brain metastases improves local control while sparing patients the toxicity associated with whole brain radiation. We review our institutional series to determine factors predictive of local failure. In a total of 39 consecutive patients with brain metastases treated from August 2011 to August 2016, 43 surgical beds were treated with HSRT in three or five fractions. All treatments were completed on a robotic radiosurgery platform using the 6D Skull tracking system. Volumetric MRIs from before and after surgery were used for radiation planning. A 2-mm PTV margin was used around the contoured surgical bed and resection margins; these were reviewed by the radiation oncologist and neurosurgeon. Lower total doses were prescribed based on proximity to critical structures or if prior radiation treatments were given. Local control in this study is defined as no volumetric MRI evidence of recurrence of tumor within the high dose radiation volume. Statistics were calculated using JMP Pro v13. Of the 43 surgical beds analyzed, 23 were from NSCLC, 5 were from breast, 4 from melanoma, 5 from esophagus, and 1 each from SCLC, sarcoma, colon, renal, rectal, and unknown primary. Ten were treated with three fractions with median dose 24 Gy and 33 were treated with five fractions with median dose 27.5 Gy using an every other day fractionation. There were no reported grade 3 or higher toxicities. Median follow up was 212 days after completion of radiation. 10 (23%) surgical beds developed local failure with a median time to failure of 148 days. All but three patients developed new brain metastases outside of the treated field and were treated with stereotactic radiosurgery, whole brain radiation and/or chemotherapy. Five patients (13%) developed leptomeningeal disease. With a median follow up of 226 days, 30 Gy/5 fx was associated with the best local control (93%) with only 1 local failure. A lower total dose in five fractions (ie 27.5 or 25 Gy) had a local control rate of 70%. For three fraction SBRT, local control was 100% using a dose of 27 Gy in three fractions (follow up was > 600 days) and 71% if 24 Gy in three fractions was used. A higher total biologically equivalent dose (BED 10 ) was statistically significant for improved local control (p = 0.04) with a threshold BED 10  ≥ 48 associated with better local control. HSRT after surgical resection for brain metastasis is well tolerated and has improved local control with BED 10  ≥ 48 (30 Gy/5 fx and 27 Gy/3 fx). Additional study is warranted.

  16. Lubiprostone, a locally acting chloride channel activator, in adult patients with chronic constipation: a double-blind, placebo-controlled, dose-ranging study to evaluate efficacy and safety.

    PubMed

    Johanson, J F; Ueno, R

    2007-06-01

    Lubiprostone, a locally acting type-2 chloride channel activator, induces intestinal fluid secretion. To assess efficacy and safety of oral lubiprostone at multiple doses for the treatment of chronic constipation. A total of 129 patients with chronic constipation were randomized to receive lubiprostone (24, 48 or 72 mcg/day) or placebo for 3 weeks. Spontaneous bowel movement (SBM) frequency, rescue medication use, symptom assessments and adverse events (AEs) were tracked. Over the double-blinded period, mean SBM frequencies were higher for lubiprostone groups (5.1-6.1) vs. placebo (3.8) and the overall difference was statistically significant (P = 0.046). SBM frequencies at week 1 were significantly higher in patients taking lubiprostone 48 or 72 mcg/day (P < or = 0.003) and, at week 2, all three lubiprostone doses yielded significantly higher SBM rates vs. placebo (P < or = 0.020). Significantly larger proportions of patients taking lubiprostone 48 and 72 mcg/day also experienced a SBM on the first treatment day (P < or = 0.009). The most common AEs were nausea, headache and diarrhoea. Lubiprostone improved SBM rates in a dose-dependent manner. AEs were tolerable for most patients. Increased AE severity at 72 mcg/day did not provide a clear risk-to-benefit advantage compared with lubiprostone 48 mcg/day, the dose chosen for subsequent Phase 3 studies.

  17. Prevalence of Adverse Effects Post-Brachytherapy on Women with Uterine Cervix Cancer in Durango, Mexico

    NASA Astrophysics Data System (ADS)

    Herrera, Higmar; Yañez, Elvia; Deras, Diana C.; Reyes, Francianella

    2010-12-01

    This work aimed at determining the local prevalence of adverse effects on women with CaCu that recieved LDR brachytherapy treatment at CECAN. The data was extracted from the patient's and medical physics' departement records. Non Gaussian statistics was used due to dose distribution characteristics. A total of 103 patients were studied with average age of 55±13 years and Ia-IV FIGO clinical clasification. The observed prevalence is higher than that reported by other studies. It was observed that patients with proctitis were prescribed a slightly higher dose than those without adverse effects (90% confidence). Patients with proctitis also presented higher age (95% confidence) when compared with the mean of the studied population. The inverse applies to the group with other adverse effects, its average age is lower than the mean (90% confidence).

  18. Impact of sacubitril/valsartan on heart failure admissions: insights from real-world patient prescriptions.

    PubMed

    Martens, Pieter; Lambeets, Seppe; Lau, Chirikwah; Dupont, Matthias; Mullens, Wilfried

    2018-06-17

    Sacubitril/valsartan reduced heart failure (HF)-admissions and cardiovascular mortality in the PARADIGM-HF-trial. However, real-world patients are often frailer and less able to tolerate high doses of sacubitril/valsartan. We performed a retrospective analysis of consecutive patients prescribed sacubitril/valsartan in a single tertiary HF-clinic between December 2016 and January 2018. HF-admissions were assessed in a paired fashion, comparing the amount of antecedent HF-episodes with incident HF-episodes after the initiation. Baseline risk for adverse events was assessed by the EMPHASIS-HF-risk-score Results: A total of 201-HF-patients were retrospectively identified (age = 68 ± 11 years, ejection fraction = 29 ± 8%). Real world patients were older, had higher serum creatinine and a higher New-York Heart-Association (NYHA)-class (p < .05 for all) than in the PARADIGM-HF trial. Over a mean duration of 221 ± 114 days after initiation of sacubitril/valsartan a total of 23-individual patients experienced at least one HF-episodes. Over the same time period preceding initiation of sacubitril/valsartan, 51 individual patients experienced a HF-episodes (p < .001). Sacubitril/valsartan significantly reduced the rate of incident vs. antecedent HF-admissions, in patients with low or high baseline NYHA-class (II vs. III and IV; p value = 0.019 respectively p = .004) or patients with an EMPHASIS-HF risk score below or above the mean (p = .002 respectively p = .016). Patients older than 75-years exhibited a trend towards HF-reduction. Higher doses of sacubitril/valsartan were associated with more reduction in incident versus antecedent HF-episodes. Despite being frailer and older, real-world patients exhibit a significant and early reduction in incident HF-hospitalisations following initiation of sacubitril/valsartan. Higher doses might be associated with more reduction in HF-admissions, underscoring the importance of dose uptitration.

  19. Effect of ascorbic acid on prevention of hypercholesterolemia induced atherosclerosis.

    PubMed

    Das, S; Ray, R; Snehlata; Das, N; Srivastava, L M

    2006-04-01

    The notion that oxidation of lipids and propagation of free radicals may contribute to the pathogenesis of atherosclerosis is supported by a large body of evidence. To circumvent the damage caused by oxygen free radicals, antioxidants are needed which provide the much needed neutralization of free radical by allowing the pairing of electrons. In this study we have investigated the effect of ascorbic acid, a water soluble antioxidant on the development of hypercholesterolemia induced atherosclerosis in rabbits. Rabbits were made hypercholesterolemic and atherosclerotic by feeding 100 mg cholesterol/day. Different doses of ascorbic acid were administered to these rabbits. Low dose of ascorbic acid (0.5 mg/100 g body weight/day) did not have any significant effect on the percent of total area covered by atherosclerotic plaque. However, ascorbic acid when fed at a higher dose (15 mg/100 g body weight/day) was highly effective in reducing the atherogenecity. With this dose the percent of total surface area covered by atherosclerotic plaque was significantly less (p < 0.001). This suggests that use of ascorbic acid may have great promise in the prevention of hypercholesterolemia induced atherosclerosis.

  20. Structured triglyceride vehicles for oral delivery of halofantrine: examination of intestinal lymphatic transport and bioavailability in conscious rats.

    PubMed

    Holm, René; Porter, Christopher J H; Müllertz, Anette; Kristensen, Henning G; Charman, William N

    2002-09-01

    To compare the influence of triglyceride vehicle intramolecular structure on the intestinal lymphatic transport and systemic absorption of halofantrine in conscious rats. Conscious, lymph cannulated and nonlymph cannulated rats were dosed orally with three structurally different triglycerides; sunflower oil, and two structured triglycerides containing different proportion and position of medium-(M) and long-chain (L) fatty acids on the glycerol backbone. The two structured triglycerides were abbreviated MLM and LML to reflect the structural position on the glycerol. The concentration of halofantrine in blood and lymph samples was analyzed by HPLC. Both the lymphatic transport and the total absorption of halofantrine were enhanced by the use the MLM triglyceride. The estimated total absorption of halofantrine in the lymph cannulated animals was higher than in the nonlymph cannulated animals, and this was most pronounced for the animals dosed with the structured triglycerides. Using MLM as vehicle increases the portal absorption of halofantrine and results in similar lymphatic transport levels when compared to sunflower oil. Total absorption when assessed as absorption in the blood plus lymphatic transport for halofantrine after administration in the MLM triglyceride was higher than after administration in sunflower oil.

  1. The effect of body condition on disposition of alkaloids from silvery lupine (Lupinus argenteus pursh) in sheep.

    PubMed

    Lopez-Ortiz, S; Panter, K E; Pfister, J A; Launchbaugh, K L

    2004-09-01

    Several species of lupine (Lupinus spp.) are poisonous to livestock, producing death in sheep and "crooked calf disease" in cattle. Range livestock cope with poisonous plants through learned foraging strategies or mechanisms affecting toxicant disposition. When a toxic plant is eaten, toxicant clearance may be influenced by the animal's nutritional and/or physiological status. This research was conducted to determine whether differences in body condition or short-term nutritional supplementation of sheep altered the disposition of lupine alkaloids given as a single oral dose of ground silvery lupine (Lupinus argenteus) seed. Ewes in average body condition (ABC, n = 9) and low body condition (LBC, n = 10) received a single dose of ground lupine seeds including pods (8.5 g/kg BW) via gavage on the first day of the experiment, and were then randomly assigned to one of two nutritional supplement treatments. Blood samples were taken 0 to 60 h after dosing to compare blood alkaloid concentration and to evaluate alkaloid absorption and elimination profiles. Concentrations of total alkaloid and anagyrine, 5,6 dehydrolupanine, lupanine, and alkaloid E were measured in serum. These four alkaloids constituted 78 and 75% of the total alkaloid concentration in serum for LBC vs. ABC groups, respectively. Initial analysis indicated that short-term supplementation had no effect on alkaloid disposition, and supplementation was removed from the statistical model. The highest concentration of total alkaloids was observed 2 h after dosing. Overall, serum total alkaloid and anagyrine levels (area under the curve) were higher (P < 0.01) for sheep in the LBC group. Serum peak concentrations of total alkaloid and anagyrine were higher in LBC vs. ABC groups (P < 0.05). Serum elimination of anagyrine, unknown alkaloid E, and lupanine was decreased in LBC vs. ABC treatments (P < 0.05). These results demonstrate that body condition is important in the disposition of lupine alkaloids; however, further research is needed to determine the potential benefit, if any, that short-term nutritional supplementation might have on alkaloid disposition.

  2. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    PubMed

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  3. Use of a hybrid iterative reconstruction technique to reduce image noise and improve image quality in obese patients undergoing computed tomographic pulmonary angiography.

    PubMed

    Kligerman, Seth; Mehta, Dhruv; Farnadesh, Mahmmoudreza; Jeudy, Jean; Olsen, Kathryn; White, Charles

    2013-01-01

    To determine whether an iterative reconstruction (IR) technique (iDose, Philips Healthcare) can reduce image noise and improve image quality in obese patients undergoing computed tomographic pulmonary angiography (CTPA). The study was Health Insurance Portability and Accountability Act compliant and approved by our institutional review board. A total of 33 obese patients (average body mass index: 42.7) underwent CTPA studies following standard departmental protocols. The data were reconstructed with filtered back projection (FBP) and 3 iDose strengths (iDoseL1, iDoseL3, and iDoseL5) for a total of 132 studies. FBP data were collected from 33 controls (average body mass index: 22) undergoing CTPA. Regions of interest were drawn at 6 identical levels in the pulmonary artery (PA), from the main PA to a subsegmental branch, in both the control group and study groups using each algorithm. Noise and attenuation were measured at all PA levels. Three thoracic radiologists graded each study on a scale of 1 (very poor) to 5 (ideal) by 4 categories: image quality, noise, PA enhancement, and "plastic" appearance. Statistical analysis was performed using an unpaired t test, 1-way analysis of variance, and linear weighted κ. Compared with the control group, there was significantly higher noise with FBP, iDoseL1, and iDoseL3 algorithms (P<0.001) in the study group. There was no significant difference between the noise in the control group and iDoseL5 algorithm in the study group. Analysis within the study group showed a significant and progressive decrease in noise and increase in the contrast-to-noise ratio as the level of IR was increased (P<0.001). Compared with FBP, readers graded overall image quality as being higher using iDoseL1 (P=0.0018), iDoseL3 (P<0.001), and iDoseL5 (P<0.001). Compared with FBP, there was subjective improvement in image noise and PA enhancement with increasing levels of iDose. The use of an IR technique leads to qualitative and quantitative improvements in image noise and image quality in obese patients undergoing CTPA.

  4. The Effect of p53 Status of Tumor Cells on Radiosensitivity of Irradiated Tumors With Carbon-Ion Beams Compared With γ-Rays or Reactor Neutron Beams.

    PubMed

    Masunaga, Shin-Ichiro; Uzawa, Akiko; Hirayama, Ryoichi; Matsumoto, Yoshitaka; Sakurai, Yoshinori; Tanaka, Hiroki; Tano, Keizo; Sanada, Yu; Suzuki, Minoru; Maruhashi, Akira; Ono, Koji

    2015-08-01

    The aim of the study was to clarify the effect of p53 status of tumor cells on radiosensitivity of solid tumors following accelerated carbon-ion beam irradiation compared with γ-rays or reactor neutron beams, referring to the response of intratumor quiescent (Q) cells. Human head and neck squamous cell carcinoma cells transfected with mutant TP53 (SAS/mp53) or with neo vector (SAS/neo) were injected subcutaneously into hind legs of nude mice. Tumor-bearing mice received 5-bromo-2'-deoxyuridine (BrdU) continuously to label all intratumor proliferating (P) cells. They received γ-rays or accelerated carbon-ion beams at a high or reduced dose-rate. Other tumor-bearing mice received reactor thermal or epithermal neutrons at a reduced dose-rate. Immediately or 9 hours after the high dose-rate irradiation (HDRI), or immediately after the reduced dose-rate irradiation (RDRI), the tumor cells were isolated and incubated with a cytokinesis blocker, and the micronucleus (MN) frequency in cells without BrdU labeling (Q cells) was determined using immunofluorescence staining for BrdU. The difference in radiosensitivity between the total (P + Q) and Q cells after γ-ray irradiation was markedly reduced with reactor neutron beams or carbon-ion beams, especially with a higher linear energy transfer (LET) value. Following γ-ray irradiation, SAS/neo tumor cells, especially intratumor Q cells, showed a marked reduction in sensitivity due to the recovery from radiation-induced damage, compared with the total or Q cells within SAS/mp53 tumors that showed little repair capacity. In both total and Q cells within both SAS/neo and SAS/mp53 tumors, carbon-ion beam irradiation, especially with a higher LET, showed little recovery capacity through leaving an interval between HDRI and the assay or decreasing the dose-rate. The recovery from radiation-induced damage after γ-ray irradiation was a p53-dependent event, but little recovery was found after carbon-ion beam irradiation. With RDRI, the radiosensitivity to reactor thermal and epithermal neutron beams was slightly higher than that to carbon-ion beams. For tumor control, including intratumor Q-cell control, accelerated carbon-ion beams, especially with a higher LET, and reactor thermal and epithermal neutron beams were very useful for suppressing the recovery from radiation-induced damage irrespective of p53 status of tumor cells.

  5. The Effect of p53 Status of Tumor Cells on Radiosensitivity of Irradiated Tumors With Carbon-Ion Beams Compared With γ-Rays or Reactor Neutron Beams

    PubMed Central

    Masunaga, Shin-ichiro; Uzawa, Akiko; Hirayama, Ryoichi; Matsumoto, Yoshitaka; Sakurai, Yoshinori; Tanaka, Hiroki; Tano, Keizo; Sanada, Yu; Suzuki, Minoru; Maruhashi, Akira; Ono, Koji

    2015-01-01

    Background The aim of the study was to clarify the effect of p53 status of tumor cells on radiosensitivity of solid tumors following accelerated carbon-ion beam irradiation compared with γ-rays or reactor neutron beams, referring to the response of intratumor quiescent (Q) cells. Methods Human head and neck squamous cell carcinoma cells transfected with mutant TP53 (SAS/mp53) or with neo vector (SAS/neo) were injected subcutaneously into hind legs of nude mice. Tumor-bearing mice received 5-bromo-2’-deoxyuridine (BrdU) continuously to label all intratumor proliferating (P) cells. They received γ-rays or accelerated carbon-ion beams at a high or reduced dose-rate. Other tumor-bearing mice received reactor thermal or epithermal neutrons at a reduced dose-rate. Immediately or 9 hours after the high dose-rate irradiation (HDRI), or immediately after the reduced dose-rate irradiation (RDRI), the tumor cells were isolated and incubated with a cytokinesis blocker, and the micronucleus (MN) frequency in cells without BrdU labeling (Q cells) was determined using immunofluorescence staining for BrdU. Results The difference in radiosensitivity between the total (P + Q) and Q cells after γ-ray irradiation was markedly reduced with reactor neutron beams or carbon-ion beams, especially with a higher linear energy transfer (LET) value. Following γ-ray irradiation, SAS/neo tumor cells, especially intratumor Q cells, showed a marked reduction in sensitivity due to the recovery from radiation-induced damage, compared with the total or Q cells within SAS/mp53 tumors that showed little repair capacity. In both total and Q cells within both SAS/neo and SAS/mp53 tumors, carbon-ion beam irradiation, especially with a higher LET, showed little recovery capacity through leaving an interval between HDRI and the assay or decreasing the dose-rate. The recovery from radiation-induced damage after γ-ray irradiation was a p53-dependent event, but little recovery was found after carbon-ion beam irradiation. With RDRI, the radiosensitivity to reactor thermal and epithermal neutron beams was slightly higher than that to carbon-ion beams. Conclusion For tumor control, including intratumor Q-cell control, accelerated carbon-ion beams, especially with a higher LET, and reactor thermal and epithermal neutron beams were very useful for suppressing the recovery from radiation-induced damage irrespective of p53 status of tumor cells. PMID:28983338

  6. Impact of the Amount of Liquid Intake on the Dose Rate of Patients Treated with Radioiodine.

    PubMed

    Haghighatafshar, Mahdi; Banani, Aida; Zeinali-Rafsanjani, Banafsheh; Etemadi, Zahra; Ghaedian, Tahereh

    2018-01-01

    Despite therapeutic effects of radioiodine in patients with differentiated thyroid cancer, there are some disadvantages due to harmful radiation to other tissues. According to the current guidelines, patients are recommended to drink lots of water and frequent voiding to reduce the amount of 131 I in the body. This study was designed to assess the impact of the amount of liquid intake on reduction of the measured dose rate of radioiodine-treated patients. A total of 42 patients with differentiated thyroid cancer without metastasis who had undergone total thyroidectomy and had been treated with radioiodine were selected. The patients were divided into two groups according to the amount of their fluid intake which was measured during the first 48 h after 131 I administration. In all patients, the dose rate was measured immediately and 48 h after iodine administration. Each group included 21 patients. Dose rate ratio (the ratio of the second dose rate to the first dose rate) and dose rate difference ratio (the ratio of the difference between the two measured dose rates to the first dose rate) were calculated for each patient. Despite the significant difference in the amount of the liquid drunk, no statistically significant difference was seen between the different groups in parameters of dose-rate ratio and dose-rate difference ratio. Higher fluid intake (>60 ml/h in our study) alone would not effectively reduce the patient's radiation dose rate at least not more than a well-hydrated state. It seems that other interfering factors in the thyroidectomized patients may also have some impacts on this physiologic process.

  7. Chronic toxicity of a mixture of chlorinated alkanes and alkenes in ICR mice.

    PubMed

    Wang, Fun-In; Kuo, Min-Liang; Shun, Chia-Tung; Ma, Yee-Chung; Wang, Jung-Der; Ueng, Tzuu-Huei

    2002-02-01

    The aim of this study was to determine the chronic toxicity of a mixture of chlorinated alkanes and alkenes (CA) consisting of chloroform, 1,1-dichloroethane, 1,1-dichloroethylene, 1,1,1-trichloroethane, trichloroethylene, and tetrachloroethylene. These chlorinated organic solvents were present in the underground water near an electronic appliances manufactory in Taoyuan, Taiwan. Male and female weanling ICR mice were treated with low-, medium-, and high-dose CA mixtures in drinking water for 16 and 18 mo, respectively. A significant number of male mice treated with the high-dose CA mixture developed tail alopecia and deformation, which was not prominent in CA-treated female mice. Medium- and high-dose CA mixtures induced marginal increases of liver and lung weights, blood urea nitrogen, and serum creatinine levels in male mice. In female mice, the high-dose CA mixture increased liver, kidney, and uterus and ovary total weights, without affecting serum biochemistry parameters. CA mixtures had no effects on the total glutathione content or the level of glutathione S-transferase activity in the livers and kid- neys of male and female mice. Treatments with CA mixtures produced a trend of increasing frequency of hepatocelluar neoplasms in male mice, compared to male and female controls and CA-treated female mice. The high-dose CA mixture induced a significantly higher incidence of mammary adenocarcinoma in female mice. The calculated odds ratios of mammary adenocarcinoma in female mice induced by low-, medium-, and high-dose CA mixtures were 1.14, 1.37, and 3.53 times that of the controls, respectively. The low-dose CA mixture induced a higher incidence of cysts and inflammation in and around the ovaries. This study has demonstrated that the CA mixture is a potential carcinogen to male and female mice. These animal toxicology data may be important in assessing the health effects of individuals exposed to the CA mixture.

  8. Vitamin D in newborns. A randomised controlled trial comparing daily and single oral bolus vitamin D in infants.

    PubMed

    Huynh, Julie; Lu, Thao; Liew, Danny; Doery, James Cg; Tudball, Ronald; Jona, Madeleine; Bhamjee, Roisin; Rodda, Christine P

    2017-02-01

    There are no published data to demonstrate the efficacy of bolus dose vitamin D in newborn infants. The study sought to evaluate this alternative approach of supplementation. This single centre, open randomised controlled trial was conducted from August 2013 to May 2014. It compared the efficacy and safety of daily (400 IU) versus a bolus dose (50 000 IU) of cholecalciferol in newborn infants of vitamin D deficient mothers. The primary outcome measure was the rate of 25 hydroxyvitamin D (25OHD) repletion-defined as 25OHD greater than 50 nmol/L. The secondary objective was determining safety using adjusted total serum calcium. Of 70 eligible infants, 36 received a daily dose and 34 received a single high-dose cholecalciferol. Mean 25OHD in the bolus group (154 nmol/L, 95% confidence interval (CI) 131-177) was higher than the daily group (48 nmol/L, 95% CI 42-54) at 1-2 weeks of age. This was reversed at 3-4 months, (65 nmol/L, 95% CI 59-71) compared with the daily group (81 nmol/L, 95% CI 77-85). More infants in the single bolus group achieved vitamin D repletion (100 vs. 31%) at 1-2 weeks. By 3-4 months, both groups achieved similar vitamin D repletion rates (91 vs. 89%). Mean adjusted total serum calcium in the bolus group were normal at 1-2 weeks (2.73 mmol/L) and 3-4 months (2.55 mmol/L). Single bolus dosing of 50 000 IU cholecalciferol achieves higher 25OHD repletion rates at 1-2 weeks of age compared with daily dosing, but repletion rates were similar by 3-4 months. There was no hypercalcaemia documented with single bolus dosing in this study. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  9. Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging system.

    PubMed

    Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro

    2018-05-01

    The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.

  10. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations.

    PubMed

    Guziński, Maciej; Waszczuk, Łukasz; Sąsiadek, Marek J

    2016-10-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. •With ASiR it is possible to lower radiation dose or improve image quality •Sequentional imaging allows setting scan parameters for brain and posterior-fossa independently •We improved visibility of brainstem structures and decreased radiation dose •Total radiation dose (DLP) was decreased by 19.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, D; Sood, S; Badkul, R

    Purpose: To compare dose distributions calculated using PB-hete vs. XVMC algorithms for SRT treatments of cavernous sinus tumors. Methods: Using PB-hete SRT, five patients with cavernous sinus tumors received the prescription dose of 25 Gy in 5 fractions for planning target volume PTV(V100%)=95%. Gross tumor volume (GTV) and organs at risk (OARs) were delineated on T1/T2 MRI-CT-fused images. PTV (range 2.1–84.3cc, mean=21.7cc) was generated using a 5mm uniform-margin around GTV. PB-hete SRT plans included a combination of non-coplanar conformal arcs/static beams delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000 MU/min) beam. Plans were re-optimized using XVMC algorithm with identicalmore » beam geometry and MLC positions. Comparison of plan specific PTV(V99%), maximal, mean, isocenter doses, and total monitor units(MUs) were evaluated. Maximal dose to OARs such as brainstem, optic-pathway, spinal cord, and lenses as well as normal tissue volume receiving 12Gy(V12) were compared between two algorithms. All analysis was performed using two-tailed paired t-tests of an upper-bound p-value of <0.05. Results: Using either algorithm, no dosimetrically significant differences in PTV coverage (PTVV99%,maximal, mean, isocenter doses) and total number of MUs were observed (all p-values >0.05, mean ratios within 2%). However, maximal doses to optic-chiasm and nerves were significantly under-predicted using PB-hete (p=0.04). Maximal brainstem, spinal cord, lens dose and V12 were all comparable between two algorithms, with exception of one patient with the largest PTV who exhibited 11% higher V12 with XVMC. Conclusion: Unlike lung tumors, XVMC and PB-hete treatment plans provided similar PTV coverage for cavernous sinus tumors. Majority of OARs doses were comparable between two algorithms, except for small structures such as optic chiasm/nerves which could potentially receive higher doses when using XVMC algorithm. Special attention may need to be paid on a case-by-case basis when planning for sinus SRT based on tumor size and location to OARs particularly the optic apparatus.« less

  12. Quality Control of Gamma Irradiated Dwarf Mallow (Malva neglecta Wallr.) Based on Color, Organic Acids, Total Phenolics and Antioxidant Parameters.

    PubMed

    Pinela, José; Barros, Lillian; Antonio, Amilcar L; Carvalho, Ana Maria; Oliveira, M Beatriz P P; Ferreira, Isabel C F R

    2016-04-08

    This study addresses the effects of gamma irradiation (1, 5 and 8 kGy) on color, organic acids, total phenolics, total flavonoids, and antioxidant activity of dwarf mallow (Malva neglecta Wallr.). Organic acids were analyzed by ultra fast liquid chromatography (UFLC) coupled to a photodiode array (PDA) detector. Total phenolics and flavonoids were measured by the Folin-Ciocalteu and aluminium chloride colorimetric methods, respectively. The antioxidant activity was evaluated based on the DPPH(•) scavenging activity, reducing power, β-carotene bleaching inhibition and thiobarbituric acid reactive substances (TBARS) formation inhibition. Analyses were performed in the non-irradiated and irradiated plant material, as well as in decoctions obtained from the same samples. The total amounts of organic acids and phenolics recorded in decocted extracts were always higher than those found in the plant material or hydromethanolic extracts, respectively. The DPPH(•) scavenging activity and reducing power were also higher in decocted extracts. The assayed irradiation doses affected differently the organic acids profile. The levels of total phenolics and flavonoids were lower in the hydromethanolic extracts prepared from samples irradiated at 1 kGy (dose that induced color changes) and in decocted extracts prepared from those irradiated at 8 kGy. The last samples also showed a lower antioxidant activity. In turn, irradiation at 5 kGy favored the amounts of total phenolics and flavonoids. Overall, this study contributes to the understanding of the effects of irradiation in indicators of dwarf mallow quality, and highlighted the decoctions for its antioxidant properties.

  13. SU-E-J-58: Dosimetric Verification of Metal Artifact Effects: Comparison of Dose Distributions Affected by Patient Teeth and Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, M; Kang, S; Lee, S

    Purpose: Implant-supported dentures seem particularly appropriate for the predicament of becoming edentulous and cancer patients are no exceptions. As the number of people having dental implants increased in different ages, critical dosimetric verification of metal artifact effects are required for the more accurate head and neck radiation therapy. The purpose of this study is to verify the theoretical analysis of the metal(streak and dark) artifact, and to evaluate dosimetric effect which cause by dental implants in CT images of patients with the patient teeth and implants inserted humanoid phantom. Methods: The phantom comprises cylinder which is shaped to simulate themore » anatomical structures of a human head and neck. Through applying various clinical cases, made phantom which is closely allied to human. Developed phantom can verify two classes: (i)closed mouth (ii)opened mouth. RapidArc plans of 4 cases were created in the Eclipse planning system. Total dose of 2000 cGy in 10 fractions is prescribed to the whole planning target volume (PTV) using 6MV photon beams. Acuros XB (AXB) advanced dose calculation algorithm, Analytical Anisotropic Algorithm (AAA) and progressive resolution optimizer were used in dose optimization and calculation. Results: In closed and opened mouth phantom, because dark artifacts formed extensively around the metal implants, dose variation was relatively higher than that of streak artifacts. As the PTV was delineated on the dark regions or large streak artifact regions, maximum 7.8% dose error and average 3.2% difference was observed. The averaged minimum dose to the PTV predicted by AAA was about 5.6% higher and OARs doses are also 5.2% higher compared to AXB. Conclusion: The results of this study showed that AXB dose calculation involving high-density materials is more accurate than AAA calculation, and AXB was superior to AAA in dose predictions beyond dark artifact/air cavity portion when compared against the measurements.« less

  14. Radiotherapy of soft tissue sarcomas in dogs.

    PubMed

    McChesney, S L; Withrow, S J; Gillette, E L; Powers, B E; Dewhirst, M W

    1989-01-01

    Megavoltage radiotherapy was administered to 42 dogs with soft tissue sarcoma. Acceptable local control of these aggressive tumors was achieved after one year of treatment. Control rates of 48 and 67% were obtained at doses of 45 and 50 gray (Gy), respectively. At 2 years, control rates decreased to 33% at the dose of 50 Gy. Serious complications developed in 4 of 42 dogs at doses of 40 to 50 Gy. The estimated dose with a 50% probability for causing serious complications was 54 Gy, given in 10 fractions. We believe that the large doses per fraction used in this study probably led to an increased probability for necrosis. Hemangiopericytomas seemed to be more responsive than fibrosarcomas. Only 2 of 11 recurrent tumors were controlled with surgery. Good local control was achieved with radiation alone for one year at doses with a low probability for serious complications; however, higher total radiation doses or combined modalities, such as surgery and radiation or radiation and hyperthermia, may be needed for longer-term control.

  15. Efficacy of two once-daily methylphenidate formulations compared across dose levels at different times of the day: preliminary indications from a secondary analysis of the COMACS study data.

    PubMed

    Sonuga-Barke, Edmund J S; Swanson, James M; Coghill, David; DeCory, Heleen H; Hatch, Simon J

    2004-09-30

    Methylphenidate (MPH) is commonly prescribed in the treatment of Attention-Deficit/Hyperactivity Disorder or ADHD. Concerta and Metadate CD are once-daily formulations of MPH using different delivery mechanisms resulting in different pharmacokinetic profiles. A recent study (COMACS) showed that for near-milligram (mg) equivalent daily doses, Metadate CD provides greater symptom control in the morning (1.5 through 4.5 hours post-dose), while Concerta provides greater control in the early evening (12 hours post-dose). Non-inferential comparison of effects for different dose levels of the two formulations suggested that equivalent levels of morning symptom control could be obtained with lower daily doses of Metadate CD than Concerta; the situation being reversed in the evening. The current paper presents a secondary analysis that provides a statistical test of these observations. The COMACS study was a multi-center, double-blind crossover study of Metadate CD, Concerta and placebo with each treatment administered for 1 week. Children were assigned on the basis of their pre-trial dosage to either high (Metadate CD 60 mg; Concerta 54 mg), medium (Metadate CD 40 mg; Concerta 36 mg) or low doses (Metadate CD 20 mg; Concerta 18 mg) of MPH, and attended a laboratory school on the 7th day for assessment at 7 sessions across the day. For the post-hoc comparisons across dose levels presented here, total SKAMP scores with the active treatments (adjusted for placebo response) were analyzed using an analysis of covariance, with a combined measure modeling placebo response across all time period as the covariate. Symptom control from 1.5 through 6.0 hours post-dose was as good with lower doses of Metadate CD (20 and 40 mg) as with higher doses of Concerta (36 and 54 mg, respectively). Lower daily doses of Concerta (18 and 36 mg) and higher doses of Metadate CD (40 and 60 mg, respectively) gave equivalent control at 7.5 and 12 hours with Metadate CD giving better control from1.5 through 6.0 hours post-dose. Different delivery profiles of Metadate CD and Concerta can be exploited to limit total daily exposure to MPH while at the same targeting a specific, especially clinically significant, period of the day. These results need to be confirmed in a study in which children are randomly allocated to different dose levels of the two formulations and plasma MPH concentrations are assessed simultaneously.

  16. Can Radiation Dose Be Reduced and Image Quality Improved With 80-kV and Dual-Phase Scanning of the Lower Extremities With 64-Slice Computed Tomography Angiography?

    PubMed

    Zhou, Yunfeng; Wang, Juan; Dassarath, Meera; Wang, Minhong; Zhang, Qiang; Xiong, Yuwei; Yuan, Quan

    2015-01-01

    To prospectively compare the new computed tomographic angiography (CTA) protocol (NCP) using 80-kV and dual-phase scanning with the routine CTA protocol (RCP) using 120-kV and single-phase scanning in patients with peripheral arterial disease. A total of 60 patients were randomized to undergo the NCP (30 patients) or RCP (30 patients) scan. We compared the arterial attenuation values, overriding of the contrast bolus, signal-to-noise ratio, and radiation dose between 2 groups. The occurrence rate of contrast bolus overriding was not statistically significant (P = 0.69). The average arterial attenuation value in the NCP group was significantly higher (P < 0.05) than that in the RCP group. The radiation dose in the RCP group was significantly higher (P < 0.001) than that in the NCP group. The mean signal-to-noise ratio in the NCP group was significantly lower (P < 0.001). Sixty-four-slice CTA with the NCP can significantly reduce the radiation dose and improve the arterial enhancement and calf arteries imaging.

  17. The Efficacy of Single-Dose versus Double-Dose Praziquantel Treatments on Schistosoma mansoni Infections: Its Implication on Undernutrition and Anaemia among Primary Schoolchildren in Two On-Shore Communities, Northwestern Tanzania

    PubMed Central

    Buza, Joram; Mpolya, Emmanuel A.; Angelo, Teckla; Kinung'hi, Safari M.

    2017-01-01

    Administering more than one treatment may increase Praziquantel cure and egg reduction rates, thereby hastening achievement of schistosomiasis transmission control. A total of 431 S. mansoni-infected schoolchildren were randomized to receive either a single or repeated 40 mg/kg Praziquantel dose. Heights, weights, and haemoglobin levels were determined using a stadiometer, weighing scale, and HemoCue, respectively. At 8 weeks, cure rate was higher on repeated dose (93.10%) compared to single dose (68.68%) (p < 0.001). The egg reduction rate was higher on repeated dose (97.54%) compared to single dose (87.27%) (p = 0.0062). Geometric mean egg intensity was lower among those on repeated dose (1.30 epg) compared to single dose (3.18 epg) (p = 0.036) but not at 5 (p > 0.05) and 8 (p > 0.05) months with no difference in reinfection rate. No difference in the prevalence of stunting was observed between the two treatment regimens (p > 0.05) at 8 months, but there was an increase in the prevalence of wasting among those on repeated dose (p < 0.001). There was an increase in the mean haemoglobin levels at 8 months with no difference between the two arms (p > 0.05). To achieve reduction of transmission intensity and disease control in highly endemic areas, repeated treatments alone may not be sufficient. This trial was registered with PACTR201601001416338. PMID:29094048

  18. Sensitivity of disease parameters to flexible budesonide/formoterol treatment in an allergic rat model.

    PubMed

    Brange, Charlotte; Smailagic, Amir; Jansson, Anne-Helene; Middleton, Brian; Miller-Larsson, Anna; Taylor, John D; Silberstein, David S; Lal, Harbans

    2009-02-01

    Clinical studies show that flexible dosing (maintenance and symptom-driven dose adjustments) of budesonide and formoterol (BUD/FORM) improves control of asthma exacerbations as compared to fixed maintenance dosing protocols (maintenance therapy) even when the latter utilize higher BUD/FORM doses. This suggests that dose-response relationships for certain pathobiologic mechanisms in asthma shift over time. Here, we have conducted animal studies to address this issue. (1) To test in an animal asthma-like model whether it is possible to achieve the same or greater pharmacological control over bronchoconstriction and airway/lung inflammation, and with less total drug used, by flexible BUD/FORM dosing (upward adjustment of doses) in association with allergen challenges. (2) To determine whether the benefit requires adjustment of both drug components. Rats sensitized on days 0 and 7 were challenged intratracheally with ovalbumin on days 14 and 21. On days 13-21, rats were treated intratracheally with fixed maintenance or flexible BUD/FORM combinations. On day 22, rats were challenged with methacholine and lungs were harvested for analysis. A flexible BUD/FORM dosing regimen (using 3.3 times less total drug than the fixed maintenance high dose regimen), delivered the same or greater reductions of excised lung gas volume (a measure of gas trapped in lung by bronchoconstriction) and lung weight (a measure of inflammatory oedema). When either BUD or FORM alone was increased on days of challenge, the benefit of the flexible dose upward adjustment was lost. Flexible dosing of the BUD/FORM combination improves the pharmacological inhibition of allergen-induced bronchoconstriction and an inflammatory oedema in an allergic asthma-like rat model.

  19. Chronic toxic and carcinogenic effects of oral cadmium in the Noble (NBL/Cr) rat: induction of neoplastic and proliferative lesions of the adrenal, kidney, prostate, and testes.

    PubMed

    Waalkes, M P; Anver, M R; Diwan, B A

    1999-10-29

    Based on the occurrence of pulmonary cancers in exposed populations, cadmium is classified as a human carcinogen. More controversial target sites for cadmium in humans include the prostate and kidney, where some studies have shown a link between cadmium and cancer. In Wistar rats cadmium induces tumors in the ventral prostate. The relevance of such lesions to humans is debated since the rat ventral lobe, unlike the dorsolateral lobe, has no embryological homolog in the human prostate. Cadmium has not been linked with renal tumors in rodents but is a potent nephrotoxin. In this work we studied the effects of oral cadmium in the Noble (NBL/Cr) rat with particular attention to proliferative lesions of the prostate and kidneys. Cadmium (as CdCl2) was given ad libitum throughout the study in the drinking water at doses of 0, 25, 50, 100, and 200 ppm Cd to groups (initial n = 30) of male rats, which were observed for up to 102 wk. At the lower doses of cadmium (< or =50 ppm) a clear dose-related increase in total proliferative lesions of the prostate (ventral and dorsolateral lesions combined) occurred (0 ppm = 21% incidence, 25 ppm = 46%, 50 ppm = 50%; trend p < .03). These lesions were described as intraepithelial hyperplasia with occasional areas of atypical epithelial cells without stromal invasion. The lesions occurred primarily in the dorsolateral prostate with cadmium exposure and most frequently showed three or more foci within each specimen. At higher doses, prostatic proliferative lesions declined to control levels. The loss of prostatic response at the higher doses was likely due to diminished testicular function secondary to cadmium treatment. This was reflected in lesions indicative of testicular hypofunction at the highest cadmium dose, namely, interstitial cell hyperplasia, and a strong correlation between cadmium dose and total proliferative lesions of the testes (hyperplasias and tumors combined). Renal tumors (mainly mesenchymal and pelvic transitional cell), although few in number, showed a positive correlation with cadmium dose, as did pelvic transitional epithelial hyperplasia. Renal lesions were not associated with any cadmium-induced changes in age-related chronic nephropathy. The incidence of pheochromocytomas of the adrenal was increased by cadmium but only at the 50 ppm dose. Inflammatory lesions of the liver and spleen were common at higher doses and showed strong trends based on dose. These results indicate that oral cadmium can induce proliferative lesions in the prostate and kidney of the Noble rat. The finding of proliferative lesions of dorsolateral prostate in rats has presumed relevance to human prostate cancers.

  20. Older adults and high-risk medication administration in the emergency department.

    PubMed

    Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J

    2017-01-01

    Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated ("High doses" were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; "very high doses" were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65-69, 70-74, 75-79, 80-84, and ≥85 years), gender, and hospital. There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65-69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56-11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69-18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26-1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07-2.16). Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65-69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted.

  1. Initial results of the use of prescription order change forms to achieve dose form optimization (consolidation and tablet splitting) of SSRI antidepressants in a state Medicaid program.

    PubMed

    Hamer, Ann M; Hartung, Daniel M; Haxby, Dean G; Ketchum, Kathy L; Pollack, David A

    2006-01-01

    One method to reduce drug costs is to promote dose form optimization strategies that take advantage of the flat pricing of some drugs, i.e., the same or nearly the same price for a 100 mg tablet and a 50 mg tablet of the same drug. Dose form optimization includes tablet splitting; taking half of a higher-strength tablet; and dose form consolidation, using 1 higher-strength tablet instead of 2 lower-strength tablets. Dose form optimization can reduce the direct cost of therapy by up to 50% while continuing the same daily dose of the same drug molecule. To determine if voluntary prescription change forms for antidepressant drugs could induce dosing changes and reduce the cost of antidepressant therapy in a Medicaid population. Specific regimens of 4 selective serotonin reuptake inhibitors (SSRIs)- citalopram, escitalopram, paroxetine, and sertraline- were identified for conversion to half tablets or dose optimization. Change forms, which served as valid prescriptions, were faxed to Oregon prescribers in October 2004. The results from both the returned forms and subsequent drug claims data were evaluated using a segmented linear regression. Citalopram claims were excluded from the cost analysis because the drug became available in generic form in October 2004. A total of 1,582 change forms were sent to 556 unique prescribers; 9.2% of the change forms were for dose consolidation and 90.8% were for tablet splitting. Of the 1,118 change forms (70.7%) that were returned, 956 (60.4% of those sent and 85.5% of those returned) authorized a prescription change to a lower-cost dose regimen. The average drug cost per day declined by 14.2%, from Dollars 2.26 to Dollars 1.94 in the intervention group, versus a 1.6% increase, from Dollars 2.52 to Dollars 2.56, in the group without dose consolidation or tablet splitting of the 3 SSRIs (sertraline, escitalopram, and immediate-release paroxetine). Total drug cost for the 3 SSRIs declined by 35.6%, from Dollars 333,567 to Dollars 214,794, as a result of a 24.8% decline in the total days of SSRI drug therapy and the 14.2% decline in average SSRI drug cost per day. The estimated monthly cost avoidance from this intervention, based on pharmacy claims data, was approximately Dollars 35,285, about 2% of the entire spending on SSRI drugs each month, or about Dollars 0.09 per member per month. Program administration costs, excluding costs incurred by prescribers and pharmacy providers, were about 2% of SSRI drug cost savings. Voluntary prescription change forms appear to be an effective and well-accepted tool for obtaining dose form optimization through dose form consolidation and tablet splitting, resulting in reduction in the direct costs of SSRI antidepressant drug therapy with minimal additional program administration costs.

  2. Ingestion dose from 238U, 232Th, 226Ra, 40K and 137Cs in cereals, pulses and drinking water to adult population in a high background radiation area, Odisha, India.

    PubMed

    Lenka, Pradyumna; Sahoo, S K; Mohapatra, S; Patra, A C; Dubey, J S; Vidyasagar, D; Tripathi, R M; Puranik, V D

    2013-03-01

    A natural high background radiation area is located in Chhatrapur, Odisha in the eastern part of India. The inhabitants of this area are exposed to external radiation levels higher than the global average background values, due to the presence of uranium, thorium and its decay products in the monazite sands bearing placer deposits in its beaches. The concentrations of (232)Th, (238)U, (226)Ra, (40)K and (137)Cs were determined in cereals (rice and wheat), pulses and drinking water consumed by the population residing around this region and the corresponding annual ingestion dose was calculated. The annual ingestion doses from cereals, pulses and drinking water varied in the range of 109.4-936.8, 10.2-307.5 and 0.5-2.8 µSv y(-1), respectively. The estimated total annual average effective dose due to the ingestion of these radionuclides in cereals, pulses and drinking water was 530 µSv y(-1). The ingestion dose from cereals was the highest mainly due to a high consumption rate. The highest contribution of dose was found to be from (226)Ra for cereals and drinking water and (40)K was the major dose contributor from the intake of pulses. The contribution of man-made radionuclide (137)Cs to the total dose was found to be minimum. (226)Ra was found to be the largest contributor to ingestion dose from all sources.

  3. Improved Pharmacokinetics of Sumatriptan With Breath Powered™ Nasal Delivery of Sumatriptan Powder

    PubMed Central

    Obaidi, Mohammad; Offman, Elliot; Messina, John; Carothers, Jennifer; Djupesland, Per G; Mahmoud, Ramy A

    2013-01-01

    Objectives.— The purpose of this study was to directly compare the pharmacokinetic (PK) profile of 22-mg sumatriptan powder delivered intranasally with a novel Breath Powered™ device (11 mg in each nostril) vs a 20-mg sumatriptan liquid nasal spray, a 100-mg oral tablet, and a 6-mg subcutaneous injection. Background.— A prior PK study found that low doses of sumatriptan powder delivered intranasally with a Breath Powered device were efficiently and rapidly absorbed. An early phase clinical trial with the same device and doses found excellent tolerability with high response rates and rapid onset of pain relief, approaching the benefits of injection despite significantly lower predicted drug levels. Methods.— An open-label, cross-over, comparative bioavailability study was conducted in 20 healthy subjects at a single center in the USA. Following randomization, fasted subjects received a single dose of each of the 4 treatments separated by a 7-day washout. Blood samples were taken pre-dose and serially over 14 hours post-dose for PK analysis. Results.— Quantitative measurement of residuals in used Breath Powered devices demonstrated that the devices delivered 8 ± 0.9 mg (mean ± standard deviation) of sumatriptan powder in each nostril (total dose 16 mg). Although the extent of systemic exposure over 14 hours was similar following Breath Powered delivery of 16-mg sumatriptan powder and 20-mg liquid nasal spray (area under the curve [AUC]0-∞ 64.9 ng*hour/mL vs 61.1 ng*hour/mL), sumatriptan powder, despite a 20% lower dose, produced 27% higher peak exposure (Cmax 20.8 ng/mL vs 16.4 ng/mL) and 61% higher exposure in the first 30 minutes compared with the nasal spray (AUC0-30 minutes 5.8 ng*hour/mL vs 3.6 ng*hour/mL). The magnitude of difference is larger on a per-milligram basis. The absorption profile following standard nasal spray demonstrated bimodal peaks, consistent with lower early followed by higher later absorptions. In contrast, the profile following Breath Powered delivery showed higher early and lower late absorptions. Relative to the 100-mg oral tablet (Cmax 70.2 ng/mL, AUC0-∞, 308.8 ng*hour/mL) and 6-mg injection (Cmax 111.6 ng/mL, AUC0-∞ 128.2 ng*hour/mL), the peak and overall exposure following Breath Powered intranasal delivery of sumatriptan powder was substantially lower. Conclusions.— Breath Powered intranasal delivery of sumatriptan powder is a more efficient form of drug delivery, producing a higher peak and earlier exposure with a lower delivered dose than nasal spray and faster absorption than either nasal spray or oral administration. It also produces a significantly lower peak and total systemic exposure than oral tablet or subcutaneous injection. PMID:23992438

  4. Long-Term Effects of Radiation Exposure and Metabolic Status on Telomere Length of Peripheral Blood T Cells in Atomic Bomb Survivors.

    PubMed

    Yoshida, Kengo; Misumi, Munechika; Kubo, Yoshiko; Yamaoka, Mika; Kyoizumi, Seishi; Ohishi, Waka; Hayashi, Tomonori; Kusunoki, Yoichiro

    2016-10-01

    In a series of studies of atomic bomb survivors, radiation-dose-dependent alterations in peripheral T-cell populations have been reported. For example, reduced size in naïve T-cell pools and impaired proliferation ability of T cells were observed. Because these alterations are also generally observed with human aging, we hypothesized that radiation exposure may accelerate the aging process of the T-cell immune system. To further test this hypothesis, we conducted cross-sectional analyses of telomere length, a hallmark of cellular aging, of naïve and memory CD4 T cells and total CD8 T cells in the peripheral blood of 620 atomic bomb survivors as it relates to age and radiation dose, using fluorescence in situ hybridization with flow cytometry. Since telomere shortening has been recently demonstrated in obesity-related metabolic abnormalities and diseases, the modifying effects of metabolic status were also examined. Our results indicated nonlinear relationships between T-cell telomere length and prior radiation exposure, i.e., longer telomeres with lower dose exposure and a decreasing trend of telomere length with individuals exposed to doses higher than 0.5 Gy. There were associations between shorter T-cell telomeres and higher hemoglobin Alc levels or fatty liver development. In naïve and memory CD4 T cells, radiation dose and high-density lipoprotein (HDL) cholesterol were found to positively interact with telomere length, suggesting that the decreasing trend of telomere length from a higher radiation dose was less conspicuous in individuals with a higher HDL cholesterol. It is therefore likely that radiation exposure perturbs T-cell homeostasis involving telomere length maintenance by multiple biological mechanisms, depending on dose, and that long-term-radiation-induced effects on the maintenance of T-cell telomeres may be modified by the subsequent metabolic conditions of individuals.

  5. Zolmitriptan 5 mg nasal spray: efficacy and onset of action in the acute treatment of migraine--results from phase 1 of the REALIZE Study.

    PubMed

    Gawel, Marek; Aschoff, Jürgen; May, Arne; Charlesworth, Bruce R

    2005-01-01

    The objective of phase 1 (reported here) of this two-phase study was to assess the efficacy of zolmitriptan 5 mg nasal spray, in terms of ability to provide relief from all migraine symptoms, in a controlled setting, designed to replicate clinical practice. Zolmitriptan nasal spray has been shown to be fast acting and highly effective in the treatment of migraine, as assessed using standard endpoints, such as headache response and pain-free rates. In the double-blind first phase of the study, patients with migraine were randomized to receive zolmitriptan 5 mg nasal spray or placebo to treat a single migraine attack. Attacks were treated according to patients' normal patterns of use, in order to closely reflect clinical practice; that is, no specific regimen was dictated in terms of time to treatment or at what level of pain intensity the headache should be treated. Patients could take a second dose of study medication or an agreed escape medication if adequate pain relief had not been achieved 2 hours after the first dose. The primary efficacy endpoint was total symptom relief (freedom from pain, nausea, photophobia, and phonophobia) 1 hour after the first dose. Secondary efficacy endpoints included headache response, pain-free status and sustained pain-free status, and ability to perform normal activities. The intention-to-treat population comprised 461 zolmitriptan nasal spray recipients and 451 placebo recipients. The total symptom relief rate 1 hour post-dose was significantly higher in the zolmitriptan 5 mg nasal spray group than in the placebo group (14.5% vs. 5.1%; P < .0001); the difference between the groups was significant from 30 minutes post-dose. Treatment with zolmitriptan nasal spray, compared with placebo, also produced a higher headache response rate from 10 minutes post-dose (15.1% vs. 9.1%; P = .0079) and a higher pain-free rate from 30 minutes post-dose (7.7% vs. 3.2%; P = .0039). Zolmitriptan nasal spray was also significantly superior to placebo in terms of sustained pain-free status and patients' ability to perform normal activities. Zolmitriptan nasal spray was well tolerated. These findings confirm the efficacy demonstrated by zolmitriptan nasal spray in previous clinical trials.

  6. Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.

    PubMed

    Kim, Hyun Gi; Lee, Ho-Joon; Lee, Seung-Koo; Kim, Hyun Ji; Kim, Myung-Joon

    2017-09-01

    To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols. A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for <3-year-old patients and applied 30% ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V. Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P < 0.001). Qualitative analysis showed higher gray-white matter differentiation and sharpness and preserved overall diagnostic quality in the images with ASIR-V. Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. • It is possible to reduce radiation dose and improve image quality with ASIR-V. • We improved noise and CNR and decreased radiation dose. • Sharpness improved with ASIR-V. • Total radiation dose was decreased by 12.8% to 34.0%.

  7. Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsayad, Khaled; Kriz, Jan; Moustakis, Christos

    Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), andmore » 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit for MF and SS patients receiving conventional dose. Low-dose TSEB regimens are well tolerated and achieve short-term palliation.« less

  8. Effect of inactivated viral vaccines (human) on frequency of micronuclei in bone marrow erythrocytes of mice.

    PubMed

    Rao, L V; Polasa, H

    1991-07-01

    Cytogenetic effects of the two inactivated viral vaccines (polio and antirabies) were studied in adult male mice by the micronucleus test. Polio salk vaccine did not induce micronuclei formation at both human (0.5 ml) and 1/5th human doses. Antirabies vaccine induced micronuclei in poly and total erythrocytes only at human dose of 2 ml. Beta-propiolactone (BPL) induced micronuclei at higher dose of 5.7 mg, but not at 0.57 mg (approximate concentration present in 2 ml of rabies vaccine). The P/N ratio was not affected in vaccinated and BPL inoculated animals. Antirabies vaccine induced micronuclei percentage was more than the BPL value.

  9. Radon exposure assessment for underground workers: a case of Seoul Subway Police officers in Korea.

    PubMed

    Song, Myeong Han; Chang, Byung-Uck; Kim, Yongjae; Cho, Kun-Woo

    2011-11-01

    The objective of this study is the systematic and individual assessment of the annual effective dose due to inhaled radon for the Seoul Subway Police officers, Korea. The annual average radon concentrations were found to be in the range of 18.9-114 Bq·m(-3) in their workplaces. The total annual effective doses which may likely to be received on duty were assessed to be in the range of 0.41-1.64 mSv·y(-1). These were well below the recommended action level 10 mSv·y(-1) by ICRP. However, the effective doses were higher than subway station staff in Seoul, Korea.

  10. Evaluation of external and internal irradiation on uranium mining enterprise staff by tooth enamel EPR spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhumadilov, Kassym; Ivannikov, Alexander; Khailov, Artem; Orlenko, Sergei; Skvortsov, Valeriy; Stepanenko, Valeriy; Kuterbekov, Kairat; Toyoda, Shin; Kazymbet, Polat; Hoshi, Masaharu

    2017-11-01

    In order to estimate radiation effects on uranium enterprise staff and population teeth samples were collected for EPR tooth enamel dosimetry from population of Stepnogorsk city and staff of uranium mining enterprise in Shantobe settlment (Akmola region, North of Kazakhstan). By measurements of tooth enamel EPR spectra, the total absorbed dose in the enamel samples and added doses after subtraction of the contribution of natural background radiation are determined. For the population of Stepnogorsk city average added dose value of 4 +/- 11 mGy with variation of 51 mGy was obtained. For the staff of uranium mining enterprise in Shantobe settlment average value of added dose 95 +/- 20 mGy, with 85 mGy variation was obtained. Higher doses and the average value and a large variation for the staff, probably is due to the contribution of occupational exposure.

  11. Higher serotonin transporter occupancy after multiple dose administration of escitalopram compared to citalopram: an [123I]ADAM SPECT study.

    PubMed

    Klein, Nikolas; Sacher, Julia; Geiss-Granadia, Thomas; Mossaheb, Nilufar; Attarbaschi, Trawat; Lanzenberger, Rupert; Spindelegger, Christoph; Holik, Alexander; Asenbaum, Susanne; Dudczak, Robert; Tauscher, Johannes; Kasper, Siegfried

    2007-04-01

    Previous studies have investigated the occupancy of the serotonin reuptake transporter (SERT) after clinical doses of citalopram and other selective serotonin reuptake inhibitors. In the present study, the occupancies of SERT after multiple doses of escitalopram and citalopram were compared using the radioligand [(123)I]ADAM and single photon emission computed tomography (SPECT). Fifteen healthy subjects received escitalopram 10 mg/day (n = 6) or citalopram 20 mg/day (n = 9) for a total of 10 days. SERT occupancies in midbrain were determined with SPECT and [(123)I]ADAM at three different time points: at baseline (no medication) and at 6 and 54 h after last drug intake. At 6 h after the last dose, mean SERT occupancies were 81.5 +/- 5.4% (mean+/-SD) for escitalopram and 64.0 +/- 12.7% for citalopram (p < 0.01). At 54 h after the last dose, mean SERT occupancies were 63.3 +/- 12.1% for escitalopram and 49.0 +/- 11.7% for citalopram (p < 0.05). The plasma concentrations of the S-enantiomer were of the same magnitude in both substances. For both drugs, the elimination rate of the S-enantiomer in plasma was markedly higher than the occupancy decline rate in the midbrain. The significantly higher occupancy of SERT after multiple doses of escitalopram compared to citalopram indicates an increased inhibition of SERT by escitalopram. The results can also be explained by an attenuating effect of R-citalopram on the occupancy of S-citalopram at the SERT.

  12. Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue

    NASA Technical Reports Server (NTRS)

    Spalding, J. F.; Holland, L. M.; Prine, J. R.; Farrer, D. N.; Braun, R. G.

    1972-01-01

    Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower.

  13. Prevalence of Adverse Effects Post-Brachytherapy on Women with Uterine Cervix Cancer in Durango, Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrera, Higmar; Yanez, Elvia; Deras, Diana C.

    2010-12-07

    This work aimed at determining the local prevalence of adverse effects on women with CaCu that recieved LDR brachytherapy treatment at CECAN. The data was extracted from the patient's and medical physics' departement records. Non Gaussian statistics was used due to dose distribution characteristics. A total of 103 patients were studied with average age of 55{+-}13 years and Ia-IV FIGO clinical clasification. The observed prevalence is higher than that reported by other studies. It was observed that patients with proctitis were prescribed a slightly higher dose than those without adverse effects (90% confidence). Patients with proctitis also presented higher agemore » (95% confidence) when compared with the mean of the studied population. The inverse applies to the group with other adverse effects, its average age is lower than the mean (90% confidence).« less

  14. The influence of folate pathway polymorphisms on high-dose methotrexate-related toxicity and survival in children with non-Hodgkin malignant lymphoma

    PubMed Central

    Erculj, Nina; Kotnik, Barbara Faganel; Debeljak, Marusa; Jazbec, Janez; Dolzan, Vita

    2014-01-01

    Background We evaluated the influence of folate pathway polymorphisms on high-dose methotrexate (HD-MTX) related toxicity in paediatric patients with T-cell non-Hodgkin lymphoma (NHL). Patients and methods In total, 30 NHL patients were genotyped for selected folate pathway polymorphisms. Results Carriers of at least one MTHFR 677T allele had significantly higher MTX area under the time-concentration curve levels at third MTX cycle (P = 0.003). These patients were also at higher odds of leucopoenia (P = 0.006) or thrombocytopenia (P = 0.041) and had higher number of different HD-MTX-related toxicity (P = 0.035) compared to patients with wild-type genotype. Conclusions Our results suggest an important role of MTHFR 677C>T polymorphism in the development of HD-MTX-related toxicity in children with NHL. PMID:25177243

  15. Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom

    PubMed Central

    Bednarz, Bryan; Hancox, Cindy; Xu, X George

    2012-01-01

    There is growing concern about radiation-induced second cancers associated with radiation treatments. Particular attention has been focused on the risk to patients treated with intensity-modulated radiation therapy (IMRT) due primarily to increased monitor units. To address this concern we have combined a detailed medical linear accelerator model of the Varian Clinac 2100 C with anatomically realistic computational phantoms to calculate organ doses from selected treatment plans. This paper describes the application to calculate organ-averaged equivalent doses using a computational phantom for three different treatments of prostate cancer: a 4-field box treatment, the same box treatment plus a 6-field 3D-CRT boost treatment and a 7-field IMRT treatment. The equivalent doses per MU to those organs that have shown a predilection for second cancers were compared between the different treatment techniques. In addition, the dependence of photon and neutron equivalent doses on gantry angle and energy was investigated. The results indicate that the box treatment plus 6-field boost delivered the highest intermediate- and low-level photon doses per treatment MU to the patient primarily due to the elevated patient scatter contribution as a result of an increase in integral dose delivered by this treatment. In most organs the contribution of neutron dose to the total equivalent dose for the 3D-CRT treatments was less than the contribution of photon dose, except for the lung, esophagus, thyroid and brain. The total equivalent dose per MU to each organ was calculated by summing the photon and neutron dose contributions. For all organs non-adjacent to the primary beam, the equivalent doses per MU from the IMRT treatment were less than the doses from the 3D-CRT treatments. This is due to the increase in the integral dose and the added neutron dose to these organs from the 18 MV treatments. However, depending on the application technique and optimization used, the required MU values for IMRT treatments can be two to three times greater than 3D CRT. Therefore, the total equivalent dose in most organs would be higher from the IMRT treatment compared to the box treatment and comparable to the organ doses from the box treatment plus the 6-field boost. This is the first time when organ dose data for an adult male patient of the ICRP reference anatomy have been calculated and documented. The tools presented in this paper can be used to estimate the second cancer risk to patients undergoing radiation treatment. PMID:19671968

  16. Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom

    NASA Astrophysics Data System (ADS)

    Bednarz, Bryan; Hancox, Cindy; Xu, X. George

    2009-09-01

    There is growing concern about radiation-induced second cancers associated with radiation treatments. Particular attention has been focused on the risk to patients treated with intensity-modulated radiation therapy (IMRT) due primarily to increased monitor units. To address this concern we have combined a detailed medical linear accelerator model of the Varian Clinac 2100 C with anatomically realistic computational phantoms to calculate organ doses from selected treatment plans. This paper describes the application to calculate organ-averaged equivalent doses using a computational phantom for three different treatments of prostate cancer: a 4-field box treatment, the same box treatment plus a 6-field 3D-CRT boost treatment and a 7-field IMRT treatment. The equivalent doses per MU to those organs that have shown a predilection for second cancers were compared between the different treatment techniques. In addition, the dependence of photon and neutron equivalent doses on gantry angle and energy was investigated. The results indicate that the box treatment plus 6-field boost delivered the highest intermediate- and low-level photon doses per treatment MU to the patient primarily due to the elevated patient scatter contribution as a result of an increase in integral dose delivered by this treatment. In most organs the contribution of neutron dose to the total equivalent dose for the 3D-CRT treatments was less than the contribution of photon dose, except for the lung, esophagus, thyroid and brain. The total equivalent dose per MU to each organ was calculated by summing the photon and neutron dose contributions. For all organs non-adjacent to the primary beam, the equivalent doses per MU from the IMRT treatment were less than the doses from the 3D-CRT treatments. This is due to the increase in the integral dose and the added neutron dose to these organs from the 18 MV treatments. However, depending on the application technique and optimization used, the required MU values for IMRT treatments can be two to three times greater than 3D CRT. Therefore, the total equivalent dose in most organs would be higher from the IMRT treatment compared to the box treatment and comparable to the organ doses from the box treatment plus the 6-field boost. This is the first time when organ dose data for an adult male patient of the ICRP reference anatomy have been calculated and documented. The tools presented in this paper can be used to estimate the second cancer risk to patients undergoing radiation treatment.

  17. Efficiency of adalimumab, etanercept and infliximab in rheumatoid arthritis patients: dosing patterns and effectiveness in daily clinical practice.

    PubMed

    Ramírez-Herráiz, Esther; Escudero-Vilaplana, Vicente; Alañón-Plaza, Estefanía; Trovato-López, Nicolás; Herranz-Alonso, Ana; Morell-Baladrón, Alberto; Sanjurjo-Sáez, María

    2013-01-01

    This retrospective, multicentre, observational study aimed to assess the mean annual doses and associated costs of three anti-tumour necrosis factor agents in daily clinical practice in rheumatoid arthritis patients, correlating these costs with disease activity. Adult rheumatoid arthritis patients were treated and followed at the Rheumatology departments of two Spanish hospitals for at least 6 months, with adalimumab, etanercept or infliximab over a 4-year period. ANOVA and multivariate statistical analyses of dosing patterns, disease activity and annualised costs were carried out. A total of 198 patients, comprising 215 cases, met the inclusion criteria (73 on adalimumab, 81 etanercept and 61 infliximab). Compared to recommended doses, mean doses of adalimumab and etanercept decreased by 7% and 19%, respectively, while the mean dose of infliximab increased by 36%. There were no statistical differences between treatments in terms of clinical effectiveness. The hazard of dose escalation was significantly higher for either adalimumab (4.4-fold) or infliximab (11.8-fold) compared to etanercept (p<0.05). Clinical control was achieved and maintained in more than half of the patients treated with reduced doses of etanercept. Associated mean patient-year costs were significantly higher in adalimumab patients (€11.962.58) (etanercept €9.594.73; infliximab €10.094.53; [p<0.05]). In rheumatoid arthritis patients, it is possible to reduce doses and associated costs of biological therapies while controlling disease activity. Mean doses used in our clinical practice were significantly lower with etanercept than with the anti-TNF monoclonal antibodies, adalimumab and infliximab. Dose differences impact directly on associated patient-year costs, and thus on treatment efficiency.

  18. SU-F-T-528: Relationship Between Tumor Size and Plan Quality Using FFF and Non-FFF Modes in Rapidarc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, F

    2016-06-15

    Purpose: For a give PTV dose, beam-on time is shorter in the FFF than the non-FFF mode because of higher MU/min. Larger tumors usually require more complex intensity modulation, which might affect plan quality and total MU. We investigated the relationship between PTV size and plan quality using FFF and non-FFF modes. Methods: Two different PTV volumes (PTV and PTV+1 cm margin) were drawn in brain, lung and liver. 3-full to 7-partial arc (Rapidarc) of 6 MV, 1400 MU/min were studied. Plan quality was evaluated by: (a) DVH for PTV and normal tissues, (b) total MU and beam-on time, andmore » (c) passing rate for IMRT plan QA. Results: For the same PTV coverage, DVH for normal tissue was the same or slightly lower in the FFF compared with non-FFF. Total MU was 13% higher in FFF than non-FFF in the 3-arc, 7 Gy treatment, but the difference became smaller when arc number increased to 6–7 for 10–24 Gy. Larger PTV did not affect the difference in the total MU. FFF required a short beam-on time and the ratio of FFF and non-FFF was 0.34 to 0.88 for 7- and 3-arc, respectively. For larger PTV, the ratio increased to 0.45–0.90. Ratio of total MU for large PTV was 3–8% lower in the non-FFF plans. Although the small difference in MU, beam-on time was 1.1 to-1.6 times longer in the 3- and 7-arc non-FFF plans. Plan verification showed the similar gamma index passing rate. Conclusion: While total MU was similar with FFF and non-FFF modes, the beam-on time was shorter in the FFF treatment. The advantage of FFF was greater in treatments with high dose per fraction using more arc numbers. For dose less than 10 Gy, using FFF and non-FFF modes, tumor size did not affect the relationship of total MU, beam-on time.« less

  19. Risk of Radiation Retinopathy in Patients With Orbital and Ocular Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaushik, Megha; Pulido, Jose S.; Schild, Steven E.

    2012-12-01

    Purpose: Radiation retinopathy is a potential long-term complication of radiation therapy to the orbit. The risk of developing this adverse effect is dose dependent; however, the threshold is unclear. The aim of this study was to identify the risk of developing radiation retinopathy at increasing radiation doses. Methods and Materials: A 40-year retrospective review was performed of patients who received external beam radiation therapy for ocular/orbital non-Hodgkin lymphoma (NHL). Results: Sixty-seven patients who had at least one ophthalmic follow-up examination were included in this study. Most patients (52%) were diagnosed with NHL involving the orbit. Patients received external beam radiationmore » therapy at doses between 1886 and 5400 cGy (mean, 3033 {+-} 782 cGy). Radiation retinopathy developed in 12% of patients, and the median time to diagnosis was 27 months (range, 15-241months). The mean prescribed radiation dose in patients with retinopathy was 3309 {+-} 585 cGy, and the estimated retinal dose (derived by reviewing the dosimetry) was 3087 {+-} 1030 cGy. The incidence of retinopathy increased with dose. The average prescribed daily fractionated dose was higher in patients who developed retinopathy than in patients who did not (mean, 202 cGy vs 180 cGy, respectively; P = .04). More patients with radiation retinopathy had comorbid diabetes mellitus type 2 than patients without retinopathy (P = .015). In our study, the mean visual acuity of the eyes that received radiation was worse than that of the eyes that did not (P = .027). Other postradiotherapy ocular findings included keratitis (6%), dry eyes (39%), and cataract (33%). Conclusions: Radiation retinopathy, a known complication of radiotherapy for orbital tumors, relates to vascular comorbidities and dose. Higher total doses and larger daily fractions (>180 cGy) appear to be related to higher rates of retinopathy. Future larger studies are required to identify a statistically significant threshold for the development of retinopathy.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell Feder and Mahmoud Z. Yousef

    Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of the ECH heating system were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture (ECH). The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken frommore » the ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and ECH cases. The ECH or Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture or ECH style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later. __________________________________________________« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell E. Feder and Mahmoud Z. Youssef

    Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of a large aperture diagnostic were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture. The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from themore » ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and Large Aperture cases. The Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later.« less

  2. Characterization and recovery of Deep Sub Micron (DSM) technologies behavior under radiation

    NASA Technical Reports Server (NTRS)

    Stoica, Adrian; Wang, Xiao

    2005-01-01

    This paper serves a twofold purpose: characterize the behavior of a reconfigurable chip exposed to radiation; and demonstrate a method for functionality recovery due to Total Ionizing Dose (TID) effects. The experiments are performed using a PL developed reconfigurable device, a Field Programmable Transistor Array (FPTA). The paper initially describes experiments on the characterization of the NMOS transistor behavior for TID values up to 300krad. The behavior of analog and digital circuits downloaded onto the FPTA chip is also assessed for TID effects. This paper also presents a novel approach for circuit functionality recovery due to radiation effects based on Evolvable Hardware. The key idea is to reconfigure a programmable device, in-situ, to compensate, or bypass its degraded or damaged components. Experiments with total radiation dose up to 300kRad show that while the functionality of a variety of circuits, including digital gates, a rectifier and a Digital to Analog Converter implemented on a FPTA-2 chip is degraded/lost at levels before 200kRad, the correct functionality can be recovered through the proposed evolutionary approach and the chips are able to survive higher radiation, for several functions in excess of total radiation dose of 250kRad.

  3. Successful pregnancy after total body irradiation and bone marrow transplantation for acute leukaemia.

    PubMed

    Giri, N; Vowels, M R; Barr, A L; Mameghan, H

    1992-07-01

    We report successful pregnancies in two young women (aged 24 and 20 years) following allogeneic bone marrow transplantation (BMT) for acute non-lymphoblastic leukaemia. Conditioning therapy consisted of cyclophosphamide (120 mg/kg) and total body irradiation (TBI, 12 Gy) in 2 Gy fractions once daily for 6 days or twice daily for 3 days. Graft-versus-host disease prophylaxis was with methotrexate alone. Both women were amenorrhoeic after BMT and gonadal testing indicated hypergonadotrophic hypogonadism. Both women had normal pregnancies (2 years and 5 years after BMT) resulting in normal healthy infants. Previously successful pregnancy has been reported after TBI in three women in whom the TBI dose was less than 8 Gy. Our cases illustrate that normal outcome of pregnancy is possible at even higher doses of TBI.

  4. The impact of histology and delivered dose on local control of spinal metastases treated with stereotactic radiosurgery.

    PubMed

    Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A; Zhang, Zhigang; Schmitt, Adam M; Higginson, Daniel S; Lis, Eric; Zelefsky, Michael J; Mechalakos, James; Bilsky, Mark H

    2017-01-01

    OBJECTIVE An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. METHODS All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3-6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor's histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. RESULTS A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2-141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7-57 months). The median prescribed dose was 2400 cGy (range 1600-2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). CONCLUSIONS High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes.

  5. The impact of histology and delivered dose on local control of spinal metastases treated with stereotactic radiosurgery

    PubMed Central

    Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A.; Zhang, Zhigang; Schmitt, Adam M.; Higginson, Daniel S.; Lis, Eric; Zelefsky, Michael J.; Mechalakos, James; Bilsky, Mark H.

    2017-01-01

    Objective An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. Methods All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3–6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor’s histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. Results A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2–141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7–57 months). The median prescribed dose was 2400 cGy (range 1600–2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). Conclusions High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes. PMID:28041329

  6. INFLUENCE OF SPIRULINA ON THE PHENYTOIN INDUCED HAEMATOLOGICAL CHANGES

    PubMed Central

    Thaakur, Santh Rani; Pushpakumari, B.

    2007-01-01

    Phenytoin is indicated for tonic clonic seizures and status epilepticus. Phenytoin is known to deplete vital nutrients such as calcium, folic acid, vitamin D, vitamin K, biotin, carnitine, copper, selenium and zinc. Depletion of nutrients is known to cause adverse effects such as ataxia, nystagmus, lethargy, slurred speech and hematological disturbances. Spirulina is a rich source of vital nutrients including iron. It is proposed to study the effect of spirulina on the hematological disturbances induced by phenytoin. Seven groups of male albino rats weighing 130-150g were used. Each group consisted of six animals. Phenytoin at a dose of 20mg/kg/day dissolved in water, spirulina 50, 100, 200 mg/kg/day suspended in 1% tween 80 alone or in combination with phenytoin was administered for 30 days. Hemoglobin content, total leucocyte and erythrocyte count were determined on 30th day. Phenytoin significantly decreased the hemoglobin content, total erythrocyte and leukocyte count. Spirulina did not show any effect at the lower dose of 50 and 100mg/kg and higher dose of 200mg/ kg significantly elevated hemoglobin content. Spirulina at a dose of 200mg/kg/day in combination with phenytoin reversed the phenytoin induced decrease in hemoglobin content, total erythrocyte and leukocyte count. The results of this study indicates that supplementation of phenytoin with spirulina may reverse the hematological disturbances induced by phenytoin. PMID:22557235

  7. Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization

    PubMed Central

    Sun, Lue; Mizuno, Yusuke; Iwamoto, Mari; Goto, Takahisa; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi

    2014-01-01

    Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose–area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. PMID:24968708

  8. Overdosing of benzodiazepines/Z-drugs and falls in older adults: Costs for the health system.

    PubMed

    Díaz-Gutiérrez, María José; Cengotitabengoa, Mónica Martínez; Bermúdez-Ampudia, Cristina; García, Sainza; López, Purificación; Martínez-Cengotitabengoa, Mayte; González-Pinto, Ana

    2018-05-08

    Benzodiazepines and Z drugs (BZD/Z drugs) are commonly used for the treatment of insomnia and anxiety in older adults for long periods of time. Given the physiological and metabolic characteristics of this group of patients, they are more prone to the adverse effects of these drugs which include falls. The recommendations for use of BZD/Z drugs include the need to adjust the dose and select those with a short half-life, to avoid adverse events, which as well as potentially affecting patient outcome, increase healthcare costs. In this study, we have evaluated the hospital-related costs associated with falls in older adults who use BZD/Z drugs at doses higher than recommended for this age group. We conducted a cross-sectional observational study assessing the BZD/Z drug prescriptions of older adults attending the emergency department after a fall. Cost analysis was performed for cases in which the prescriptions exceeded the maximum recommended dose for this age group. A total of 40.6% of the prescriptions recorded were higher than the defined daily dose in older adults (DDD olderadults ). Of the 57 patients who used BZD/Z drugs at higher-than-recommended doses, 53 experienced trauma and 33 required hospitalisation. The costs associated with emergency department services, tests performed and hospitalisation amounted to €1850/patient. Appropriate dosage of BZD/Z drugs in older adults could reduce both patient suffering and costs for the health system. Copyright © 2017. Published by Elsevier Inc.

  9. [High doses of aspirin reduce natriuresis in hypertensive patients treated with enalapril].

    PubMed

    Di Gennaro, Federico P; Cingolani, Oscar H; Abbate, Alejandro F; Toblli, Jorge E; Vilches, Antonio

    2004-01-01

    Angiotensin converting enzyme inhibitors have been shown to be useful in the treatment of essential hypertension while anti-platelet agents improve the overall cardiovascular risk profile in this population. Our aim was to assess the interaction of two different aspirin (ASA) doses--81 and 325 mg/day--with the antihypertensive effect of enalapril as well as their impact upon the urinary sodium excretion (Na(u)). A total of 22 patients between 35 and 65 years of age were included in a prospective double blind trial with a partial cross-over design. We excluded patients with secondary hypertension and recent use of anti-inflammatory drugs. Patients were placed on enalapril and a low sodium diet--<6 g of NaCl/day--and, sequentially, on two different doses of aspirin separated by a 10 day wash out period. Blood pressure (BP) was measured at weekly visits. Systolic, diastolic and mean BP levels decreased significantly in enalapril-treated patients (p<0.01) and no difference was detected between the two AAS dosages although a non-statistically significant difference towards better BP control was observed when 81 mg of ASA was used. Na(u) was higher at baseline when compared with the two periods under ASA (p<0.01) and Na(u) was higher with 81 mg than with 325 mg. These results suggest that in essential hypertensive individuals treated with enalapril and two ASA doses, low doses of ASA are associated with better blood pressure control and higher natriuresis.

  10. Advanced techniques in neoadjuvant radiotherapy allow dose escalation without increased dose to the organs at risk : Planning study in esophageal carcinoma.

    PubMed

    Fakhrian, K; Oechsner, M; Kampfer, S; Schuster, T; Molls, M; Geinitz, H

    2013-04-01

    The goal of this work was to investigate the potential of advanced radiation techniques in dose escalation in the radiotherapy (RT) for the treatment of esophageal carcinoma. A total of 15 locally advanced esophageal cancer (LAEC) patients were selected for the present study. For all 15 patients, we created a 3D conformal RT plan (3D-45) with 45 Gy in fractions of 1.8 Gy to the planning target volume (PTV1), which we usually use to employ in the neoadjuvant treatment of LAEC. Additionally, a 3D boost (as in the primary RT of LAEC) was calculated with 9 Gy in fractions of 1.8 Gy to the boost volume (PTV2) (Dmean) to a total dose of 54 Gy (3D-54 Gy), which we routinely use for the definitive treatment of LAEC. Three plans with a simultaneous integrated boost (SIB) were then calculated for each patient: sliding window intensity-modulated radiotherapy (IMRT-SIB), volumetric modulated arc therapy (VMAT-SIB), and helical tomotherapy (HT-SIB). For the SIB plans, the requirement was that 95 % of the PTV1 receive ≥ 100 % of the prescription dose (45 Gy in fractions of 1.8 Gy, D95) and the PTV2 was dose escalated to 52.5 Gy in fractions of 2.1 Gy (D95). The median PTV2 dose for 3D-45, 3D-54, HT-SIB, VMAT-SIB, and IMRT-SIB was 45, 55, 54, 56, and 55 Gy, respectively. Therefore, the dose to PTV2 in the SIB plans was comparable to the 3D-54 plan. The lung dose in the SIB plans was in the range of the standard 3D-45, which is applied for neoadjuvant radiotherapy. The mean lung dose for the same plans was 13, 15, 12, 12, and 13 Gy, respectively. The V5 lung volumes were 71, 74, 79, 75, and 73 %, respectively. The V20 lung volumes were 20, 25, 16, 18, and 19 %, respectively. New treatment planning techniques enable higher doses to be delivered for neoadjuvant radiotherapy of LAEC without a significant increase in the delivered dose to the organs at risk. Clinical investigations are warranted to study the clinical safety and feasibility of applying higher doses through advanced techniques in the neoadjuvant treatment of LAEC.

  11. Higher dose rate Gamma Knife radiosurgery may provide earlier and longer-lasting pain relief for patients with trigeminal neuralgia.

    PubMed

    Lee, John Y K; Sandhu, Sukhmeet; Miller, Denise; Solberg, Timothy; Dorsey, Jay F; Alonso-Basanta, Michelle

    2015-10-01

    Gamma Knife radiosurgery (GKRS) utilizes cobalt-60 as its radiation source, and thus dose rate varies as the fixed source decays over its half-life of approximately 5.26 years. This natural decay results in increasing treatment times when delivering the same cumulative dose. It is also possible, however, that the biological effective dose may change based on this dose rate even if the total dose is kept constant. Because patients are generally treated in a uniform manner, radiosurgery for trigeminal neuralgia (TN) represents a clinical model whereby biological efficacy can be tested. The authors hypothesized that higher dose rates would result in earlier and more complete pain relief but only if measured with a sensitive pain assessment tool. One hundred thirty-three patients were treated with the Gamma Knife Model 4C unit at a single center by a single neurosurgeon during a single cobalt life cycle from January 2006 to May 2012. All patients were treated with 80 Gy with a single 4-mm isocenter without blocking. Using an output factor of 0.87, dose rates ranged from 1.28 to 2.95 Gy/min. The Brief Pain Inventory (BPI)-Facial was administered before the procedure and at the first follow-up office visit 1 month from the procedure (mean 1.3 months). Phone calls were made to evaluate patients after their procedures as part of a retrospective study. Univariate and multivariate linear regression was performed on several independent variables, including sex, age in deciles, diagnosis, follow-up duration, prior surgery, and dose rate. In the short-term analysis (mean 1.3 months), patients' self-reported pain intensity at its worst was significantly correlated with dose rate on multivariate analysis (p = 0.028). Similarly, patients' self-reported interference with activities of daily living was closely correlated with dose rate on multivariate analysis (p = 0.067). A 1 Gy/min decrease in dose rate resulted in a 17% decrease in pain intensity at its worst and a 22% decrease in pain interference with activities of daily living. In longer-term follow-up (mean 1.9 years), GKRS with higher dose rates (> 2.0 Gy/min; p = 0.007) and older age in deciles (p = 0.012) were associated with a lower likelihood of recurrence of pain. Prior studies investigating the role of dose rate in Gamma Knife radiosurgical ablation for TN have not used validated outcome tools to measure pain preoperatively. Consequently, differences in pain outcomes have been difficult to measure. By administering pain scales both preoperatively as well as postoperatively, the authors have identified statistically significant differences in pain intensity and pain interference with activities of daily living when comparing higher versus lower dose rates. Radiosurgery with a higher dose rate results in more pain relief at the early follow-up evaluation, and it may result in a lower recurrence rate at later follow-up.

  12. Oxidative stress in a model of toxic demyelination in rat brain: the effect of piracetam and vinpocetine.

    PubMed

    Abdel-Salam, Omar M E; Khadrawy, Yasser A; Salem, Neveen A; Sleem, Amany A

    2011-06-01

    We studied the role of oxidative stress and the effect of vinpocetine (1.5, 3 or 6 mg/kg) and piracetam (150 or 300 mg/kg) in acute demyelination of the rat brain following intracerebral injection of ethidium bromide (10 μl of 0.1%). ethidium bromide caused (1) increased malondialdehyde (MDA) in cortex, hippocampus and striatum; (2) decreased total antioxidant capacity (TAC) in cortex, hippocampus and striatum; (3) decreased reduced glutathione (GSH) in cortex and hippocampus (4); increased serum nitric oxide and (5) increased striatal (but not cortical or hippocampal) acetylcholinesterase (AChE) activity. MDA decreased in striatum and cortex by the lower doses of vinpocetine or piracetam but increased in cortex and hippocampus and in cortex, hypothalamus and striatum by the higher dose of vinpocetine or piracetam, respectively along with decreased TAC. GSH increased by the higher dose of piracetam and by vinpocetine which also decreased serum nitric oxide. Vinpocetine and piracetam displayed variable effects on regional AChE activity.

  13. A Voxel-Based Approach to Explore Local Dose Differences Associated With Radiation-Induced Lung Damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palma, Giuseppe; Monti, Serena; D'Avino, Vittoria

    Purpose: To apply a voxel-based (VB) approach aimed at exploring local dose differences associated with late radiation-induced lung damage (RILD). Methods and Materials: An interinstitutional database of 98 patients who were Hodgkin lymphoma (HL) survivors treated with postchemotherapy supradiaphragmatic radiation therapy was analyzed in the study. Eighteen patients experienced late RILD, classified according to the Radiation Therapy Oncology Group scoring system. Each patient's computed tomographic (CT) scan was normalized to a single reference case anatomy (common coordinate system, CCS) through a log-diffeomorphic approach. The obtained deformation fields were used to map the dose of each patient into the CCS. Themore » coregistration robustness and the dose mapping accuracy were evaluated by geometric and dose scores. Two different statistical mapping schemes for nonparametric multiple permutation inference on dose maps were applied, and the corresponding P<.05 significance lung subregions were generated. A receiver operating characteristic (ROC)-based test was performed on the mean dose extracted from each subregion. Results: The coregistration process resulted in a geometrically robust and accurate dose warping. A significantly higher dose was consistently delivered to RILD patients in voxel clusters near the peripheral medial-basal portion of the lungs. The area under the ROC curves (AUC) from the mean dose of the voxel clusters was higher than the corresponding AUC derived from the total lung mean dose. Conclusions: We implemented a framework including a robust registration process and a VB approach accounting for the multiple comparison problem in dose-response modeling, and applied it to a cohort of HL survivors to explore a local dose–RILD relationship in the lungs. Patients with RILD received a significantly greater dose in parenchymal regions where low doses (∼6 Gy) were delivered. Interestingly, the relation between differences in the high-dose range and RILD seems to lack a clear spatial signature.« less

  14. High-dose anti-histamine use and risk factors in children with urticaria

    PubMed Central

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-01-01

    Aim The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. Material and Methods The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. Results The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p<0.0001). There was no difference between the two groups in terms of blood eosinophil and basophil counts, and serum total IgE levels (p>0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=−0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03–1.15]) and basopenia (OR: 6.77; CI 95%: [2.01–22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. Conclusion The requirement of high-dose H1-antihistamines was higher with children’s increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines. PMID:28123332

  15. Predictive factors of head and neck squamous cell carcinoma patient tolerance to high-dose cisplatin in concurrent chemoradiotherapy

    PubMed Central

    NAKANO, KENJI; SATO, YASUYOSHI; TOSHIYASU, TAKASHI; SATO, YUKIKO; INAGAKI, LINA; TOMOMATSU, JUNICHI; SASAKI, TORU; SHIMBASHI, WATARU; FUKUSHIMA, HIROFUMI; YONEKAWA, HIROYUKI; MITANI, HIROKI; KAWABATA, KAZUYOSHI; TAKAHASHI, SHUNJI

    2016-01-01

    Although high-dose cisplatin is the standard regimen of concurrent chemoradiotherapy (CCRT) for locally advanced head and neck squamous cell carcinoma (HNSCC), varying levels of patient tolerance towards cisplatin have been reported, and the predictive factors of cisplatin tolerance remain to be elucidated. The present study retrospectively reviewed newly diagnosed HNSCC patients who received CCRT. Cisplatin (80 mg/m2) was administered every 3 weeks. The proportion of high-dose cisplatin-tolerant patients (cumulative cisplatin dose, ≥200 mg/m2) was determined, and the predictive factors of cisplatin tolerance were analyzed in a logistic regression analysis. Between June 2006 and March 2013, a total of 159 patients were treated with CCRT. The median follow-up time was 36.7 months. A total of 73 patients (46%) tolerated a cumulative cisplatin dose ≥200 mg/m2; male gender [odds ratio (OR), 25.00; P=0.005] and high body surface area (BSA) (>1.80 m2; OR, 2.21; P=0.032) were significantly predictive of high-dose cisplatin tolerance. The high-dose cisplatin-tolerant patients had a significantly higher complete response (CR) rate (82 vs. 67%, P=0.045); however, there were no significant between-group differences in the 3-year OS (79.5 vs. 81.2%, P=0.59) or PFS (70.4 vs. 44.6%, P=0.076) by cisplatin tolerance. In clinical practice, approximately one-half of the patients tolerated high-dose cisplatin in CCRT. Male gender and high BSA could be predictive of cisplatin tolerance. PMID:26893880

  16. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Storb, R.; Raff, R.F.; Graham, T.

    1993-03-20

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing [sup 60]Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionatedmore » total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs.« less

  17. Effects of n-3 polyunsaturated fatty acids and vitamin E on colonic mucosal leukotriene generation, lipid peroxidation, and microcirculation in rats with experimental colitis.

    PubMed

    Shimizu, T; Igarashi, J; Ohtuka, Y; Oguchi, S; Kaneko, K; Yamashiro, Y

    2001-01-01

    We investigated the effect of n-3 polyunsaturated fatty acids (PUFAs) on mucosal levels of leukotrienes (LTs) and lipid peroxide (LPO), and on mucosal microcirculation, in rats with experimental colitis induced by dextran sulfate sodium (DSS). We fed Wistar rats a perilla oil-enriched diet containing alpha-linolenic acid (63.2% of total fatty acids) with various doses of vitamin E for 4 weeks, with 4% DSS added to the drinking water during the last week. Control rats were fed a diet produced from soybean oil containing alpha-linolenic acid (5.1% of total fatty acids). Colonic mucosal blood flow was measured with a laser Doppler flowmeter. The mucosal level of arachidonic acid was significantly lower and that of eicosapentaenoic acid was significantly higher in the experimental group. The mucosal level of LPO in the experimental group fed a trace or ordinary dose of vitamin E was significantly higher than that of the controls. The production of LTB(4) and LTC(4) from the colonic mucosa in the experimental group was significantly lower than that in controls. However, only the experimental group fed a vitamin E dose 4-fold higher than that given to the controls showed a significant increase in mucosal blood flow. These results suggest that n-3 PUFAs increase mucosal blood flow by inhibiting LT production when there is sufficient vitamin E to inhibit lipid peroxidation in rats with experimental colitis. Copyright 2001 S. Karger AG, Basel

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrison, F.L.; Rice, D.W. Jr.

    The usefulness of sister chromatid exchange (SCE) induction as a measure of low-level radiation effect was examined in a benthic marine worm, Neanthes arenaceodentata. Larvae were exposed to /sup 60/Co radiation for 12 to 24 h at total doses ranging from 0.5 to 309 R and at dose rates from 0.04 to 13 R/h. Animals exposed at intermediate dose rates (0.5, 0.6, 1.25, 2.0, and 2.5 R/h) had SCE frequencies per chromosome about twice that of those receiving no radiation (controls), whereas those exposed at the higher dose rates (7.0 and 13 R/h) had SCE frequencies lower than the controls.more » Animals exposed at the lower dose rates (0.04 and 0.1 R/h) had lower SCE frequencies than those exposed at intermediate dose rates (and higher SCE frequencies than controls). The length of chromosome pair number one differed among metaphase spreads and was used as an index of chromosome condensation in a given metaphase. Because there is a possibility that chromosome morphology may affect the ability to resolve SCEs, morphology will be monitored in future studies. A preliminary experiment was performed to assess the effects of 2.2 and 11.5 R/h for 24 h on growth and development. Larvae observed at 6 and 17 d after irradiation did not have significantly different numbers of abnormal larvae or survival rates.« less

  19. Determinants of antipyretic misuse in children up to 5 years of age: a cross-sectional study.

    PubMed

    Bilenko, Natalya; Tessler, Hedva; Okbe, Ranya; Press, Joseph; Gorodischer, Rafael

    2006-05-01

    Fever in children is a common and usually benign symptom. It is known that antipyretic treatment is ineffective in the prevention of simple febrile seizures. Caregivers' administration of antipyretic medications to children has been reported, but data concerning the formulations used, actual doses administered, and effects of ethnicity and socioeconomic status on administration practices are incomplete. The aim of this study was to identify the factors affecting antipyretic administration (higher-than-recommended doses in particular) by caregivers to their febrile children in 2 differing cultural-ethnic backgrounds. This cross-sectional survey study, conducted from January to March 2002, was part of a larger, ongoing survey study of the differences in care givers' knowledge, beliefs, and attitudes concerning children's fever in the 2 major cultural-ethnic groups in the Negev District in Israel: Jews and Bedouin Moslems. It was conducted at the Pediatric Emergency Department (PED), Soroka Medical Center, Beer-Sheva, Israel. A structured questionnaire was administered to Jewish and Bedouin Moslem parents or usual caregivers of young (age, 0-60 months) children attending the PED due to fever. Each child's weight was obtained from the PED medical record. After completion of the interview, the reported antipyretic dose per kilogram of body weight was calculated. Less-than-recommended dose was defined as <9 mg/kg for acetaminophen and <4.5 mg/kg for ibuprofen. Higher-than-recommended dose was defined as >16.5 mg/kg for acetaminophen and >11 mg/kg for ibuprofen. The caregivers of a total of 201 children (mean [SD] age, 20 [17] months; mean [SD] weight, 10.4 [4.0] kg) were included in the study. The study included 101 Jewish and 100 Bedouin Moslem caregivers. The proportion of people surveyed who were parents was 98%; grandmothers, 2%. Differences existed between the 2 cultural-ethnic groups in the source of knowledge regarding antipyretic use in children (a significantly larger proportion of Jewish caregivers received their knowledge concerning antipyretic use from package inserts compared with Bedouin caregivers [25.7% vs 6.0%; P < 0.001], and a significantly lower proportion of Jewish caregivers used "other" sources [15.8% vs 39.0%; P < 0.001]). Most (65.2%) caregivers indicated that they administered antipyretics for no or minimal elevations in body temperature (<-38 degrees C); 52.7% administered individual acetaminophen doses within 10% of the recommended dose, 34.8 % administered a higher-than-recommended dose, and 21.4% repeated the dose at intervals of

  20. Importance of 6-mercaptopurine dose in lymphoblastic leukaemia.

    PubMed Central

    Hale, J P; Lilleyman, J S

    1991-01-01

    To explore the possibility that higher total dosage of 'maintenance' treatment may have contributed to the recent improvement in outlook of children in the United Kingdom with lymphoblastic leukaemia, details of the amount of 6-mercaptopurine prescribed during the first two years of treatment were studied in an unselected cohort of children diagnosed between 1973 and 1987. Eighty five patients were studied, 30 diagnosed before and 55 after 1980. The group diagnosed after 1980 showed an 18% improvement in relapse free survival at five years. Their median total dose of 6-mercaptopurine had increased by 22%, whereas according to the protocol it should have risen by an average of only 9%. After 1980 boys were prescribed significantly more 6-mercaptopurine than girls, and had fewer dose reductions because of myelosuppression. These findings support the clinical impression that after 1980 an important therapeutic difference resulting from the new United Kingdom acute lymphoblastic leukaemia protocols was an increase in the amount of 6-mercaptopurine that children actually received as a result of changes in prescribing guidelines rather than dose. They also provide further evidence that boys tolerate 6-mercaptopurine better than girls, which may be related to the still unexplained difference in prognosis between the sexes. PMID:2031601

  1. Oxidative stress induced in PCB 126-exposed northern leopard frogs, Rana pipiens

    USGS Publications Warehouse

    Huang, Y.-W.; Hoffman, D.J.; Karasov, W.H.

    2007-01-01

    Northern leopard frogs Rana pipiens exposed to PCB 126 (3,3',4,4',5-pentachlorobiphenyl) were examined for hepatic oxidative stress. In a dose-response study, northern leopard frogs were injected intraperitoneally with either PCB 126 in corn oil (0.2, 0.7, 2.3, or 7.8 mg/kg body weight) or corn oil alone. In a time-course study, frogs received 7.8 mg/kg or corn oil alone, and were examined at 1, 2, 3, and 4 wk after dosing. Hepatic concentrations of reduced glutathione (GSH), thiobarbituric acid-reactive substances (TBARS), and total sulfhydryls (total SH), as well as activities of glutathione peroxidase (GSH-P), GSSG reductase (GSSG-R), glucose-6-phosphate dehydrogenase (G-6-PDH), and glutathione S-transferase (GSH-S-T) were measured. In the dose-response experiment, few effects were apparent 1 wk after dosing. In the time-course experiment, significant changes were observed in the 7.8-mg/kg group at 2 wk or more posttreatment. Hepatic concentrations of GSH and TBARS were higher than in corresponding controls at wk 3 and 4; the activities of GSSG-R and GSH-S-T were higher than in controls at wk 2 and 4; and the activity of G-6-PDH was increased at wk 2 and 4. These data collectively indicate that altered glutathione metabolism and oxidative stress occurred and were indicative of both toxicity and induction of protective mechanisms in frogs exposed to PCB. A similar delay in response was reported in fish and may relate to lower metabolic rate and physiological reactions in ectothermic vertebrates

  2. Thalidomide results in diminished ovarian reserve in reproductive age female IBD patients

    PubMed Central

    Peng, Xiang; Zhi, Min; Wei, Ming; Li, Ting-Ting; Zhang, Min; Zhang, Yuan-Qi; He, Huan; Su, Mingli; Wang, Wei; Chen, Jun-rong; Tang, Jian; Gao, Xiang; Hu, Pin-Jin; Liang, Xiao-Yan

    2017-01-01

    Abstract The effectiveness of thalidomide in treating inflammatory bowel disease (IBD) has been widely recognized. Meanwhile, many serious adverse drug reactions have been observed, but no know reports on ovarian reserve function. Female patients, ranging in age between 18 and 40, were referred to our institution to undergo sex hormone detection and ultrasonic scanning for ovarian function assessment, between February 1, 2016 and September 31, 2016. Thirty-three patients treated with thalidomide (group A), 73 patients without thalidomide (group B), and 78 healthy women as control were studied. Menstrual disorder was higher in group A than group B (78.8% vs 57.2%, P < 0.05), and both groups were higher than control group 33.3%, P < 0.05. Anti-Mullerian hormone (AMH) levels and antral follicle count (AFC) in group A were lower than group B, P < 0.05, while estradiol (E2) and follicle-stimulating hormone (FSH) levels were no different between 2 groups. Crohn Disease Endoscopic Index of Severity (CDEIS) and thalidomide were the independent risk factors in diminished ovarian reserve (DOR), and when dose reached 75 mg/day, 5 g total, or when treatment time reached 10 months respectively. These influence may increasing (P < 0.05), but they may recover after stopping (P < 0.05). Thalidomide was an independent risk factor leading to DOR in female IBD patients, the influence may increasing when daily dose and accumulated dose reached 75 mg/day and 5 g total dose, but may be reversed by stopping. PMID:28538364

  3. Oxidative stress induced in PCB 126-exposed northern leopard frogs, Rana pipiens.

    PubMed

    Huang, Yue-wern; Hoffman, David J; Karasov, William H

    2007-04-15

    Northern leopard frogs Rana pipiens exposed to PCB 126 (3,3',4,4',5-pentachlorobiphenyl) were examined for hepatic oxidative stress. In a dose-response study, northern leopard frogs were injected intraperitoneally with either PCB 126 in corn oil (0.2, 0.7, 2.3, or 7.8 mg/kg body weight) or corn oil alone. In a time-course study, frogs received 7.8 mg/kg or corn oil alone, and were examined at 1, 2, 3, and 4 wk after dosing. Hepatic concentrations of reduced glutathione (GSH), thiobarbituric acid-reactive substances (TBARS), and total sulfhydryls (total SH), as well as activities of glutathione peroxidase (GSH-P), GSSG reductase (GSSG-R), glucose-6-phosphate dehydrogenase (G-6-PDH), and glutathione S-transferase (GSH-S-T) were measured. In the dose-response experiment, few effects were apparent 1 wk after dosing. In the time-course experiment, significant changes were observed in the 7.8-mg/kg group at 2 wk or more posttreatment. Hepatic concentrations of GSH and TBARS were higher than in corresponding controls at wk 3 and 4; the activities of GSSG-R and GSH-S-T were higher than in controls at wk 2 and 4; and the activity of G-6-PDH was increased at wk 2 and 4. These data collectively indicate that altered glutathione metabolism and oxidative stress occurred and were indicative of both toxicity and induction of protective mechanisms in frogs exposed to PCB. A similar delay in response was reported in fish and may relate to lower metabolic rate and physiological reactions in ectothermic vertebrates.

  4. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses.

    PubMed

    Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L

    2004-03-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18 x 7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186+/-8 mm and 147+/-8 mm, respectively, with an average HU value of 209+/-40. An infant head was found to be equivalent to a water cylinder with a radius of approximately 60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is approximately 20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors.

  5. Effects of VKORC1 Genetic Polymorphisms on Warfarin Maintenance Dose Requirement in a Chinese Han Population

    PubMed Central

    Yan, Xiaojuan; Yang, Feng; Zhou, Hanyun; Zhang, Hongshen; Liu, Jianfei; Ma, Kezhong; Li, Yi; Zhu, Jun; Ding, Jianqiang

    2015-01-01

    Background VKORC1 is reported to be capable of treating several diseases with thrombotic risk, such as cardiac valve replacement. Some single-nucleotide polymorphisms (SNPs) in VKORC1 are documented to be associated with clinical differences in warfarin maintenance dose. This study explored the correlations of VKORC1–1639 G/A, 1173 C/T and 497 T/G genetic polymorphisms with warfarin maintenance dose requirement in patients undergoing cardiac valve replacement. Material/Methods A total of 298 patients undergoing cardiac valve replacement were recruited. During follow-up, clinical data were recorded. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method was applied to detect VKORC1–1639 G/A, 1173 C/T and 497 T/G polymorphisms, and genotypes were analyzed. Results Correlations between warfarin maintenance dose and baseline characteristics revealed statistical significances of age, gender and operation methods with warfarin maintenance dose (all P<0.05). Warfarin maintenance dose in VKORC1–1639 G/A AG + GG carriers was obviously higher than in AA carriers (P<0.001). As compared with patients with TT genotype in VKORC1 1173 C/T, warfarin maintenance dose was apparently higher in patients with CT genotype (P<0.001). Linear regression analysis revealed that gender, operation method, method for heart valve replacement, as well as VKORC1–1639 G/A and 1173 C/T gene polymorphisms were significantly related to warfarin maintenance dose (all P<0.05). Conclusions VKORC1 gene polymorphisms are key genetic factors to affect individual differences in warfarin maintenance dose in patients undergoing cardiac valve replacement; meanwhile, gender, operation method and method for heart valve replacement might also be correlate with warfarin maintenance dose. PMID:26583785

  6. Fault handling schemes in electronic systems with specific application to radiation tolerance and VLSI design

    NASA Technical Reports Server (NTRS)

    Attia, John Okyere

    1993-01-01

    Naturally occurring space radiation particles can produce transient and permanent changes in the electrical properties of electronic devices and systems. In this work, the transient radiation effects on DRAM and CMOS SRAM were considered. In addition, the effect of total ionizing dose radiation of the switching times of CMOS logic gates were investigated. Effects of transient radiation on the column and cell of MOS dynamic memory cell was simulated using SPICE. It was found that the critical charge of the bitline was higher than that of the cell. In addition, the critical charge of the combined cell-bitline was found to be dependent on the gate voltage of the access transistor. In addition, the effect of total ionizing dose radiation on the switching times of CMOS logic gate was obtained. The results of this work indicate that, the rise time of CMOS logic gates increases, while the fall time decreases with an increase in total ionizing dose radiation. Also, by increasing the size of the P-channel transistor with respect to that of the N-channel transistor, the propagation delay of CMOS logic gate can be made to decrease with, or be independent of an increase in total ionizing dose radiation. Furthermore, a method was developed for replacing polysilicon feedback resistance of SRAMs with a switched capacitor network. A switched capacitor SRAM was implemented using MOS Technology. The critical change of the switched capacitor SRAM has a very large critical charge. The results of this work indicate that switched capacitor SRAM is a viable alternative to SRAM with polysilicon feedback resistance.

  7. Safety and efficacy of fixed-dose 10 mg daily isotretinoin treatment for acne vulgaris in Malaysia.

    PubMed

    Yap, Felix Boon-Bin

    2017-09-01

    Low-dose isotretinoin is used to reduce side effects albeit higher relapse. This study aimed to determine the efficacy and safety of fixed-dose 10 mg daily isotretinoin for the treatment of acne. This prospective study was performed between 2011 and 2015. All 150 patients were given 10 mg daily isotretinoin until a cumulative dose of 90-110 mg/kg. The mean age was 26.6 years with 64.7% moderate acne, 29.3% severe, and 6% very severe. The mean cumulative dose was 98.8 ± 6.05 mg/kg. All 150 patients had total clearance with a mean time to clearance of 24.0 weeks. Patients with severe/very severe acne had higher cumulative dosage (102.1 vs. 97.0, P < 0.001) and longer duration to clearance (32.9 weeks vs. 19.1 weeks, P < 0.001). Mild relapse was seen in 4%. The mean time to relapse was 32.3 weeks. Lip dryness was the commonest side effects (100%). Mild transient elevation of liver enzymes was detected in 3.3% and a slight increase of serum lipid in 2.7% with no treatment discontinuation. Fixed-dose 10 mg daily treatment with isotretinoin until a cumulative dose of 90-110 mg/kg is safe with low relapse rate. © 2016 Wiley Periodicals, Inc.

  8. Symptoms Associated with Dietary Fiber Supplementation over Time in Individuals with Fecal Incontinence

    PubMed Central

    Bliss, Donna Z.; Savik, Kay; Jung, Hans-Joachim G.; Whitebird, Robin; Lowry, Ann

    2011-01-01

    Background Knowledge about adverse symptoms over time from fiber supplementation is lacking. Purpose To compare the severity of adverse gastrointestinal (GI) symptoms during supplementation with dietary fiber or placebo over time in adults with fecal incontinence. Secondary aims were to determine the relationship between symptom severity and emotional upset and their association with study attrition and reducing fiber dose. Methods Subjects (N=189, 77% female, 92% white, (age = 58 years, SD = 14) with fecal incontinence were randomly assigned to placebo or a supplement of 16g total dietary fiber/day from one of three sources: gum arabic, psyllium, or carboxymethylcellulose. They reported GI symptoms daily during baseline (14 days), incremental fiber dosing (6 days), and two segments of steady full fiber dose (32 days total). Results Severity of symptoms in all groups was minimal. Adjusting for study segment and day, a greater feeling of fullness in the psyllium group was the only symptom that differed from symptoms in the placebo group. Odds of having greater severity of flatus, belching, fullness, and bloating were 1.2–2.0 times greater in the steady dose segment compared to baseline. There was a positive association between symptom severity and emotional upset. Subjects with a greater feeling of fullness or bloating or higher scores for total symptom severity or emotional upset were more likely to withdraw from the study sooner or reduce fiber dose. Conclusions Persons with fecal incontinence experience a variety of GI symptoms over time. Symptom severity and emotional upset appear to influence fiber tolerance and study attrition. Supplements seemed well tolerated. PMID:21543963

  9. A systematic review on clinical benefits of continuous administration of beta-lactam antibiotics.

    PubMed

    Roberts, Jason A; Webb, Steven; Paterson, David; Ho, Kwok M; Lipman, Jeffrey

    2009-06-01

    The clinical benefits of extended infusion or continuous infusion of beta-lactam antibiotics remain controversial. We systematically reviewed the literature to determine whether any clinical benefits exist for administration of beta-lactam antibiotics by extended or continuous infusion. PubMed (January 1950 to November 2007), EMBASE (1966 to November 2007), and the Cochrane Controlled Trial Register were searched (updated November 2007). Randomized controlled trials (RCTs) were meta-analyzed, and observational studies were described by two unblinded reviewers. A total of 846 patients from eligible prospective randomized controlled studies were included in the meta-analysis. Two observational studies were deemed appropriate for description. A meta-analysis of prospective RCTs was undertaken using Review Manager. Among a total of 59 potentially relevant studies, 14 RCTs involving a total of 846 patients from nine countries were deemed appropriate for meta-analysis. The use of continuous infusion of a beta-lactam antibiotic was not associated with an improvement in clinical cure (n = 755 patients; odds ratio: 1.04, 95% confidence interval: 0.74-1.46, p = 0.83, I = 0%) or mortality (n = 541 patients; odds ratio: 1.00, 95% confidence interval: 0.48-2.06, p = 1.00, I = 14.8%). All RCTs except one used a higher antibiotic dose in the bolus administration group. Two observational studies, not pooled because they did not meet the a priori criteria for meta-analysis, showed that beta-lactam administration by extended or continuous infusion was associated with an improvement in clinical cure. The difference in the results between the meta-analysis results and the observational studies could be explained by the bias created by a higher dose of antibiotic in the bolus group in the RCTs and because many of the RCTs only recruited patients with a low acuity of illness. The limited data available suggest that continuous infusion of beta-lactam antibiotics leads to the same clinical results as higher dosed bolus administration in hospitalized patients.

  10. Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV.

    PubMed

    Gudowska, I; Brahme, A; Andreo, P; Gudowski, W; Kierkegaard, J

    1999-09-01

    The absorbed dose due to photonuclear reactions in soft tissue, lung, breast, adipose tissue and cortical bone has been evaluated for a scanned bremsstrahlung beam of end point 50 MeV from a racetrack accelerator. The Monte Carlo code MCNP4B was used to determine the photon source spectrum from the bremsstrahlung target and to simulate the transport of photons through the treatment head and the patient. Photonuclear particle production in tissue was calculated numerically using the energy distributions of photons derived from the Monte Carlo simulations. The transport of photoneutrons in the patient and the photoneutron absorbed dose to tissue were determined using MCNP4B; the absorbed dose due to charged photonuclear particles was calculated numerically assuming total energy absorption in tissue voxels of 1 cm3. The photonuclear absorbed dose to soft tissue, lung, breast and adipose tissue is about (0.11-0.12)+/-0.05% of the maximum photon dose at a depth of 5.5 cm. The absorbed dose to cortical bone is about 45% larger than that to soft tissue. If the contributions from all photoparticles (n, p, 3He and 4He particles and recoils of the residual nuclei) produced in the soft tissue and the accelerator, and from positron radiation and gammas due to induced radioactivity and excited states of the nuclei, are taken into account the total photonuclear absorbed dose delivered to soft tissue is about 0.15+/-0.08% of the maximum photon dose. It has been estimated that the RBE of the photon beam of 50 MV acceleration potential is approximately 2% higher than that of conventional 60Co radiation.

  11. Evaluation of an ultra-low-dose oral contraceptive for dysmenorrhea: a placebo-controlled, double-blind, randomized trial.

    PubMed

    Harada, Tasuku; Momoeda, Mikio

    2016-12-01

    To evaluate the efficacy and safety of an ultra-low-dose oral contraceptive (NPC-01; 0.02 mg ethinyl estradiol and 1 mg norethisterone) in subjects with dysmenorrhea. Placebo-controlled, double-blind, randomized trial. Clinical trial sites. Two hundred fifteen subjects with dysmenorrhea. Subjects were randomly assigned to receive NPC-01, placebo, or IKH-01 (0.035 mg ethinyl estradiol and 1 mg norethisterone) for four cycles. Total dysmenorrhea score (verbal rating scale) assessing pain on the basis of limited ability to work and need for analgesics. The reductions of total dysmenorrhea score and visual analog scale score after the treatment were significantly higher in the NPC-01 group than in the placebo group. Furthermore, the efficacy of NPC-01 was comparable to that of IKH-01. The overall incidence of side effects was significantly higher in the NPC-01 group than in the placebo group. All side effects that occurred in the NPC-01 group were previously reported in patients receiving IKH-01. No serious side effects occurred. The ultra-low-dose contraceptive NPC-01 relieved dysmenorrhea as effectively as IKH-01. Thus, NPC-01 could represent a new option for long-term treatment of dysmenorrhea. NCT01129102. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  12. Risk of Late Urinary Complications Following Image Guided Adaptive Brachytherapy for Locally Advanced Cervical Cancer: Refining Bladder Dose-Volume Parameters.

    PubMed

    Manea, Elena; Escande, Alexandre; Bockel, Sophie; Khettab, Mohamed; Dumas, Isabelle; Lazarescu, Ioana; Fumagalli, Ingrid; Morice, Philippe; Deutsch, Eric; Haie-Meder, Christine; Chargari, Cyrus

    2018-06-01

    To study correlations between dose-volume parameters of the whole bladder and bladder trigone and late urinary toxicity in locally advanced cervical cancer patients treated with pulsed-dose-rate brachytherapy. Patients with locally advanced cervical cancer treated with chemoradiation therapy and pulsed-dose-rate brachytherapy from 2004 to 2015 were included. Cumulative dose-volume parameters of the whole bladder and bladder trigone were converted into 2-Gy/fraction equivalents (EQD2, with α/β = 3 Gy); these parameters, as well as clinical factors, were analyzed as predictors of toxicity in patients without local relapse. A total of 297 patients fulfilled the inclusion criteria. The median follow-up period was 4.9 years (95% confidence interval 4.5-5.3 years). In patients without local relapse (n = 251), the Kaplan-Meier estimated grade 2 or higher urinary toxicity rates at 3 years and 5 years were 25.4% and 32.1%, respectively. Minimal dose to the most exposed 2 cm 3 of the whole bladder [Formula: see text] , bladder International Commission on Radiation Units & Measurements (ICRU) (B ICRU ) dose, and trigone dose-volume parameters correlated with grade 2 or higher toxicity. At 3 years, the cumulative incidence of grade 2 or higher complications was 22.8% (standard error, 2.9%) for bladder [Formula: see text]  < 80 Gy EQD2 versus 61.8% (standard error, 12.7%) for [Formula: see text]  ≥ 80 Gy EQD2 (P = .001). In the subgroup of patients with bladder [Formula: see text]  ≤ 80 Gy EQD2 , a trigone dose delivered to 50% of the volume (D 50% ) > 60 Gy EQD2 was significant for grade 2 or higher toxicity (P = .027). The probability of grade 3 or higher toxicities increased with bladder [Formula: see text]  > 80 Gy EQD2 (16.7% vs 1.6%; hazard ratio [HR], 5.77; P = .039), B ICRU dose > 65 Gy EQD2 (4.9% vs 1.3%; HR, 6.36; P = .018), and trigone D 50%  > 60 Gy EQD2 (3.1% vs 1.2%; HR, 6.29; P = .028). Pearson correlation coefficients showed a moderate correlation between bladder [Formula: see text] , B ICRU dose, and bladder trigone D 50% (P < .0001). These data suggest that [Formula: see text]  ≤ 80 Gy EQD2 should be advised for minimizing the risk of severe urinary complications (<15%). Bladder trigone dose was also predictive of severe late urinary toxicity. These constraints need further confirmation in a multicenter prospective setting. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. A comparison of menotropin, highly-purified menotropin and follitropin alfa in cycles of intracytoplasmic sperm injection

    PubMed Central

    Esteves, Sandro C; Schertz, Joan C; Verza, Sidney; Schneider, Danielle T; Zabaglia, Silval FC

    2009-01-01

    Background Over the last several decades, as a result of an evolution in manufacturing processes, a marked development has been made in the field of gonadotropins for ovarian stimulation. Initially, therapeutic gonadotropins were produced from a simple process of urine extraction and purification; now they are produced via a complex system involving recombinant technology, which yields gonadotropins with high levels of purity, quality, and consistency. Methods A retrospective analysis of 865 consecutive intracytoplasmic sperm injection (ICSI) cycles of controlled ovarian hyperstimulation (COH) compared the clinical efficacy of three gonadotropins (menotropin [hMG; n = 299], highly-purified hMG [HP-hMG; n = 330] and follitropin alfa [r-hFSH; n = 236]) for ovarian stimulation after pituitary down-regulation. The endpoints were live birth rates and total doses of gonadotropin per cycle and per pregnancy. Results Laboratory and clinical protocols remained unchanged over time, except for the type of gonadotropin used, which was introduced sequentially (hMG, then HP-hMG, and finally r-hFSH). Live birth rates were not significantly different for hMG (24.4%), HP-hMG (32.4%) and r-hFSH (30.1%; p = 0.09) groups. Total dose of gonadotropin per cycle was significantly higher in the hMG (2685 +/- 720 IU) and HP-hMG (2903 +/- 867 IU) groups compared with the r-hFSH-group (2268 +/- 747 IU; p < 0.001). Total dose of gonadotropin required to achieve clinical pregnancy was 15.7% and 11.0% higher for the hMG and HP-hMG groups, respectively, compared with the r-hFSH group, and for live births, the differences observed were 45.3% and 19.8%, respectively. Conclusion Although similar live birth rates were achieved, markedly lower doses of r-hFSH were required compared with hMG or HP-hMG. PMID:19828024

  14. Minimization of CYP2D6 Polymorphic Differences and Improved Bioavailability via Transdermal Administration: Latrepirdine Example.

    PubMed

    Chew, Marci L; Mordenti, Joyce; Yeoh, Thean; Ranade, Gautam; Qiu, Ruolun; Fang, Juanzhi; Liang, Yali; Corrigan, Brian

    2016-08-01

    Transdermal delivery has the potential to offer improved bioavailability by circumventing first-pass gut and hepatic metabolism. This study evaluated the pharmacokinetics of oral immediate release and transdermal latrepirdine in extensive and poor CYP2D6 metabolizers (EM/PM). Latrepirdine transdermal solution was prepared extemporaneously. The solution was applied with occlusive dressing to upper or middle back for 24 h. Each subject received a single dose of 8.14 mg oral, 5 mg transdermal, and 10 mg transdermal (EMs only) latrepirdine free base in a fixed sequence. Twelve EMs and 7 PMs (50-79 years) enrolled and completed the study. Latrepirdine was well tolerated following both routes of administration. Dose-normalized latrepirdine total exposures were approximately 11-fold and 1.5-fold higher in EMs and PMs, respectively following administration of transdermal relative to oral. Differences between EM and PM latrepirdine exposures were decreased, with PMs having 1.9- and 2.7-fold higher peak and total exposures, respectively, following transdermal administration compared to 11- and 20-fold higher exposures, respectively, following oral administration. Transdermal delivery can potentially mitigate the large intersubject differences observed with compounds metabolized primarily by CYP2D6. Transdermal delivery was readily accomplished in the clinic using an extemporaneously prepared solution [NCT00990613].

  15. A limited sampling model for estimation of total and unbound mycophenolic acid (MPA) area under the curve (AUC) in hematopoietic cell transplantation (HCT).

    PubMed

    Ng, Juki; Rogosheske, John; Barker, Juliet; Weisdorf, Daniel; Jacobson, Pamala A

    2006-06-01

    Renal transplant patients with suboptimal mycophenolic acid (MPA) areas under the curves (AUCs) are at greater risk of acute rejection. In hematopoietic cell transplantation, a low MPA AUC is also associated with a higher incidence of acute graft versus host disease. Therefore, a limited sampling model was developed and validated to simultaneously estimate total and unbound MPA AUC0-12 in hematopoietic cell transplantation patients. Intensive pharmacokinetic sampling was performed at steady state between days 3 to 7 posttransplant in 73 adult subjects while receiving prophylactic mycophenolate mofetil 1 g per 12 hours orally or intravenously plus cyclosporine. Total and unbound MPA plasma concentrations were measured, and total and unbound AUC0-12 was determined using noncompartmental analysis. Regression analysis was then performed to build IV and PO, total and unbound AUC0-12 models from the first 34 subjects. The predictive performance of these models was tested in the next 39 subjects. Trough concentrations poorly estimate observed total and unbound AUC0-12 (r<0.48). A model with 3 concentrations (2-, 4-, and 6-hour post start of infusion) best estimated observed total and unbound AUC0-12 after IV dosing (r>0.99). Oral total and unbound AUC0-12 was more difficult to estimate and required at least 4 concentrations (0-, 1-, 2-, and 6-hour post dose) in the model (r>0.85). The predictive performance of the final models was good. Eighty-three percent of IV and 70% of PO AUC0-12 predictions fell within +/-20% of the observed values without significant bias. Trough MPA concentrations do not accurately describe MPA AUC0-12. Three intravenous (2-, 4-, 6-hour post start of infusion) or 4 oral (0-, 1-, 2-, and 6-hour post dose) MPA plasma concentrations measured over a 12-hour dosing interval will estimate the total and unbound AUC0-12 nearly as well as intensive pharmacokinetic sampling with good precision and low bias. This approach simplifies AUC0-12 targeting of MPA post hematopoietic cell transplantation.

  16. Antioxidant properties of methanol extract and its solvent fractions obtained from selected Indian red seaweeds.

    PubMed

    Ganesan, P; Kumar, Chandini S; Bhaskar, N

    2008-05-01

    In vitro antioxidant activities of three selected Indian red seaweeds - viz., Euchema kappaphycus, Gracilaria edulis and Acanthophora spicifera were evaluated. Total phenolic content and reducing power of crude methanol extract were determined. The antioxidant activities of total methanol extract and five different solvent fractions (viz., petroleum ether (PE), ethyl acetate (EA), dichloromethane (DCM), butanol (BuOH) and aqueous) were also evaluated. EA fraction of A. spicifera exhibited higher total antioxidant activity (32.01 mg ascorbic acid equivalent/g extract) among all the fractions. Higher phenolic content (16.26 mg gallic acid equivalent/g extract) was noticed in PE fraction of G. edulis. Reducing power of crude methanol extract increased with increasing concentration of the extract. Reducing power and hydroxyl radical scavenging activity of E. kappaphycus were higher compared to standard antioxidant (alpha-tocopherol). The total phenol content of all the seaweeds was significantly different (P<0.05). In vitro antioxidant activities of methanol extracts of all the three seaweeds exhibited dose dependency; and increased with increasing concentration of the extract.

  17. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children.

    PubMed

    Aw-Zoretic, J; Seth, D; Katzman, G; Sammet, S

    2014-10-01

    The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10-18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Age-specific radiation dose commitment factors for a one-year chronic intake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoenes, G.R.; Soldat, J.K.

    1977-11-01

    During the licensing process for nuclear facilities, radiation doses and dose commitments must be calculated for people in the environs of a nuclear facility. These radiation doses are determined by examining characteristics of population groups, pathways to people, and radionuclides found in those pathways. The pertinent characteristics, which are important in the sense of contributing a significant portion of the total dose, must then be analyzed in depth. Dose factors are generally available for adults, see Reference 1 for example, however numerous improvements in data on decay schemes and half-lives have been made in recent years. In addition, it ismore » advisable to define parameters for calculation of the radiation dose for ages other than adults since the population surrounding nuclear facilities will be composed of various age groups. Further, since infants, children, and teens may have higher rates of intake per unit body mass, it is conceivable that the maximally exposed individual may not be an adult. Thus, it was necessary to develop new radiation-dose commitment factors for various age groups. Dose commitment factors presented in this report have been calculated for a 50-year time period for four age groups.« less

  19. Assessment of occupational cosmic radiation exposure of flight attendants using questionnaire data.

    PubMed

    Anderson, Jeri L; Waters, Martha A; Hein, Misty J; Schubauer-Berigan, Mary K; Pinkerton, Lynne E

    2011-11-01

    Female flight attendants may have a higher risk of breast and other cancers than the general population because of routine exposure to cosmic radiation. As part of a forthcoming study of breast and other cancer incidence, occupational cosmic radiation exposure of a cohort of female flight attendants was estimated. Questionnaire data were collected from living female cohort members who were formerly employed as flight attendants with Pan American World Airways. These data included airline at which the flight attendant was employed, assigned domicile, start and end dates for employment at domicile, and number of block hours and commuter segments flown per month. Questionnaire respondents were assigned daily absorbed and effective doses using a time-weighted dose rate specific to the domicile and/or work history era combined with self-reported work history information. Completed work history questionnaires were received from 5898 living cohort members. Mean employment time as a flight attendant was 7.4 yr at Pan Am and 12 yr in total. Estimated mean annual effective dose from all sources of occupational cosmic radiation exposure was 2.5 +/- 1.0 mSv, with a mean career dose of 30 mSv. Annual effective doses were similar to doses assessed for other flight attendant cohorts; however, questionnaire-based cumulative doses assessed in this study were on average higher than those assessed for other flight attendant cohorts using company-based records. The difference is attributed to the inclusion of dose from work at other airlines and commuter flights, which was made possible by using questionnaire data.

  20. Diuretic downsides--but in low doses they still seem among the best authenticated antihypertensives.

    PubMed

    Opie, L H

    2000-08-01

    Diuretics in low doses have the greatest support among current available antihypertensives in that they have been shown to reduce total mortality, coronary mortality, stroke, and congestive heart failure in an important meta-analysis by Psaty. Recently, Messerli has linked longterm diuretic use to renal cell carcinoma in women. In some patients, diuretic use leads to increasing blood cholesterol and blood sugar levels. Impotence is a recognized side effect, with rates rising about twofold with low-dose chlorthalidone and fourfold with a higher dose. Certain population groups such as younger (<60 years) white males often do not respond to low-dose diuretic therapy with an adequate blood pressure fall. In females of a similar age group, Messerli calculates that prolonged diuretic therapy will prevent only one stroke and no coronary events nor any deaths for every renal cell carcinoma that is provoked. Despite these evident problems, the outcome data on hard endpoints in trials with initial low-dose diuretic therapy remain valid and convincing. Thus, it is argued, low- but not high-dose diuretics retain their primacy in the ranking of antihypertensive therapy.

  1. Efficacy of topotecan treatment on antioxidant enzymes and TBA-RS levels in submandibular glands of rabbits: an experimental study.

    PubMed

    Muluk, Nuray Bayar; Kisa, Uçler; Kaçmaz, Murat; Apan, Alpaslan; Koç, Can

    2005-01-01

    The aim of this study was to investigate the effects of topotecan (Hycamtin), a topoisomerase I inhibiting anticancer agent, on antioxidant enzymes (SOD, CAT, and GSH-Px) and TBA-RS values of the submandibular glands of the rabbits. The study was conveyed in two groups (Group I, II) and control with a total of 24 rabbits. Eight rabbits in group I received intravenous (i.v.) topotecan (0.25 mg/kg once daily) for 3 days. Eight rabbits in group II received i.v. topotecan (0.5 mg/kg once daily) for 3 days. On the 15th day after administration of topotecan, submandibular glands were removed and levels of the SOD, CAT, and GSH-Px and the TBA-RS in the submandibular glands of the rabbits were examined. SOD, CAT, and GSH-Px values were significantly higher in high-dose topotecan group compared to control group (P < 0.05). SOD and TBA-RS values were significantly higher in high-dose topotecan group compared to low-dose topotecan group (P < 0.05). It was concluded that, to prevent the hazardous effects of oxygen free radicals due to topotecan, antioxidant enzymes SOD, CAT, and GSH-Px were increased. The higher levels of the TBA-RS values in group II showed that permanent damage was present because of high-dose topotecan administration in the submandibular glands of the rabbits.

  2. Systematic review: standard- and double-dose proton pump inhibitors for the healing of severe erosive oesophagitis -- a mixed treatment comparison of randomized controlled trials.

    PubMed

    Edwards, S J; Lind, T; Lundell, L; DAS, R

    2009-09-15

    No randomized controlled trial (RCT) has compared all European-licensed standard- and double-dose PPIs for the healing of severe erosive oesophagitis. To compare the effectiveness of licensed doses of PPIs for healing severe erosive oesophagitis (i.e. esomeprazole 40 mg, lansoprazole 30 mg, omeprazole 20 mg and 40 mg, pantoprazole 40 mg and rabeprazole 20 mg). Systematic review of CENTRAL, EMBASE and MEDLINE for RCTs in patients with erosive oesophagitis (completed October 2008). Endoscopically verified healing rates at 4 and 8 weeks were extracted and re-calculated if not analysed by intention-to-treat. A mixed treatment comparison was used to combine direct treatment comparisons with indirect trial evidence while maintaining randomization. Odds ratios (OR) are reported compared to omeprazole 20 mg. A total of 3021 papers were identified in the literature search; 12 were of sufficient quality to be included in the analysis. Insufficient data were available to included rabeprazole. Esomeprazole 40 mg was found to provide significantly higher healing rates at 4 weeks [OR 1.84, 95% Credible Interval (95% CrI): 1.50 to 2.22] and 8 weeks (OR 1.91, 95% CrI: 1.13 to 2.88). No other PPI investigated had significantly higher healing rates than omeprazole 20 mg. Esomeprazole 40 mg consistently demonstrates higher healing rates compared with licensed standard- and double-dose PPIs.

  3. Low vs. higher-dose dark chocolate and blood pressure in cardiovascular high-risk patients.

    PubMed

    Desch, Steffen; Kobler, Daniela; Schmidt, Johanna; Sonnabend, Melanie; Adams, Volker; Sareban, Mahdi; Eitel, Ingo; Blüher, Matthias; Schuler, Gerhard; Thiele, Holger

    2010-06-01

    Dark chocolate may have blood pressure-lowering properties. We conducted a prospective randomized open-label blinded end-point design trial to study a potential dose dependency of the presumed antihypertensive effect of dark chocolate by directly comparing low vs. higher doses of dark chocolate over the course of 3 months. We enrolled a total of 102 patients with prehypertension/stage 1 hypertension and established cardiovascular end-organ damage or diabetes mellitus. Patients were randomly assigned to receive either 6 or 25 g/day of flavanol-rich dark chocolate for 3 months. The difference in 24-h mean blood pressure between groups was defined as the primary outcome measure. Significant reductions in mean ambulatory 24-h blood pressure were observed between baseline and follow-up in both groups (6 g/day: -2.3 mm Hg, 95% confidence interval -4.1 to -0.4; 25 g/day: -1.9 mm Hg, 95% confidence interval -3.6 to -0.2). There were no significant differences in blood pressure changes between groups. In the higher-dose group, a slight increase in body weight was noted (0.8 kg, 95% confidence interval 0.06 to 1.6). The findings are consistent with the hypothesis that dark chocolate may be associated with a reduction in blood pressure (BP). However, due to the lack of a control group, confounding may be possible and the results should be interpreted with caution.

  4. Variables associated with emergency department and/or unplanned hospital utilization for children with epilepsy.

    PubMed

    Patel, Anup D

    2014-02-01

    In the United States, approximately one million people are evaluated annually in an emergency department (ED) for the diagnosis of a seizure or epilepsy. The highest percentages of these patients are less than five years of age. No studies have been performed on assessing potential variables associated with recurrent ED visits and/or unplanned hospitalizations for children with epilepsy. Institutional review board approval from Nationwide Children's Hospital was obtained prior to study initiation. An accountable care organization (ACO), Partner for Kids (PFK), database was searched for patients with the highest and the lowest number of ED visits and/or unplanned hospitalizations from 2007 through 2011 using ICD-9 codes of 345.xx and 780.39. The patients were stratified into a high and a low utilizer group. The total number of visits and their associated health care costs were noted for each patient. In total, 120 patients were included for review. Information on the total number of no-shows to outpatient neurology clinic visits and telephone calls to neurology triage nursing was noted. A chart review was performed by a pediatric epileptologist to determine if each individual patient was an appropriate candidate for an emergency seizure treatment. The dose of emergency seizure medication was cross-checked to the patient's actual dose during the time of ED or hospital presentation to determine if the dose given was high, low, or accurate based on dosing recommendations. Multivariable logistic regression was used to test the effects of factors. When controlling for other factors, patients who were given an incorrect or no emergency seizure dosing had a high probability of having multiple ED visits/unplanned hospitalizations compared with patients who were given correct dosing (odds ratio=11.28, 95% CI of odds ratio=(2.42, 52.63), p value<0.01 (p=0.0021)). Using a similar model, patients who experienced a higher number of no-shows to clinic visits had a higher probability of having multiple ED visits/unplanned hospitalizations (odds ratio=5.73 per 1 more number of no-show, 95% CI of odds ratio=(1.78, 18.44), p value<0.01 (p=0.0034)). Future studies are planned to target these risk factors with the goal of decreased ED and/or hospital utilization for children with epilepsy. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. A randomized controlled trial of preprocedure administration of parecoxib for therapeutic endoscopic retrograde cholangiopancreatography.

    PubMed

    Amornyotin, Somchai; Chalayonnawin, Wiyada; Kongphlay, Siriporn

    2012-01-01

    Parecoxib is occasionally used for analgesia in postprocedural patients. The clinical efficacy of parecoxib used for endoscopic retrograde cholangiopancreatography (ERCP) is controversial. The aim of the study was to determine the clinical efficacy of preprocedure administration of parecoxib for therapeutic ERCP patients. Eighty-five patients who underwent therapeutic ERCP in a single year were randomly assigned to normal saline group (C, n = 43) and parecoxib group (P, n = 42). Patients in group C received normal saline and those in group P received 40 mg of parecoxib intravenously in equivalent volume. Patients in both groups received the saline or parecoxib 60 seconds before administration of the sedative agents. All patients were monitored for the depth of sedation by using the Narcotrend(TM) monitor, maintaining stage D0-E0 during ERCP. All patients were oxygenated with 100% O(2) via nasal cannula and sedated with 0.03 mg/kg of intravenous midazolam and 1 μg/kg of intravenous fentanyl as well as the titration of intravenous propofol. After the ERCP procedure, pethidine in an intramuscular dose of 0.5-1.0 mg/kg was used as rescue medication. The pain scores (visual analog scale [VAS], 0-10) at 2, 12, and 24 hours post-ERCP, the total number of doses of pethidine used, the dose volume of pethidine used, patient satisfaction, endoscopist satisfaction, and complications were recorded. There were no significant differences in sedative and analgesic agents used during the procedure, pain at 24 hours post-ERCP, endoscopist satisfaction, and complications in both groups. The total number of doses of pethidine used post-ERCP in group C was significantly higher than in group P. Additionally, the mean pain score at 2 and 12 hours post-ERCP in group C was significantly greater than in group P. Patient satisfaction in group P was higher than in group C. Preprocedure administration of parecoxib for therapeutic ERCP patients was clinically effective. The analgesic efficacy of a standard dose of parecoxib was clearly demonstrated during the first 12 hours postprocedure. Additionally, patient satisfaction in the parecoxib group was also higher than in the control group.

  6. Effects of Increasing Doses of UV-B on Main Phenolic Acids Content, Antioxidant Activity and Estimated Biomass in Lavandin (Lavandula x intermedia).

    PubMed

    Usano-Alemany, Jaime; Panjai, Lachinee

    2015-07-01

    Lavandin is a well-known aromatic plant cultivated mainly for its valuable essential oil. Nonetheless, little attention has been paid so far to the quantification of other natural products such as polyphenols. Accordingly, we examined the effect of increasing doses of UV-B radiation on the main phenolic content, antioxidant activity and estimated biomass of one year old lavandin pots compared with pots grown outdoors. Significantly higher total phenolic content and concentration of main polyphenols have been found in outdoor plants. Rosmarinic acid has been described as the major phenolic compound in methanolic extracts (max. 25.9 ± 9.7 mg/g(-1) DW). Furthermore, we found that increasing doses of UV-B promote the plant growth of this species as well as the accumulation of phenolic compounds although with less antioxidant capacity in scavenging DPPH radicals. On the other hand, our results showed a remarkable variability among individual plants regarding the content of major phenolic acids. The application of UV-B doses during plant growth could be a method to promote biomass in this species along with the promotion of higher content of valuable secondary metabolites.

  7. Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy.

    PubMed

    Rong, Yi; Yadav, Poonam; Welsh, James S; Fahner, Tasha; Paliwal, Bhudatt

    2012-01-01

    The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments. Published by Elsevier Inc.

  8. Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rong Yi, E-mail: rong@humonc.wisc.edu; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI; Yadav, Poonam

    2012-10-01

    The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTVmore » received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.« less

  9. Pharmacokinetic/pharmacodynamic modeling and simulation of neutropenia during phase I development of liposome-entrapped paclitaxel.

    PubMed

    Fetterly, Gerald J; Grasela, Thaddeus H; Sherman, Jeffrey W; Dul, Jeanne L; Grahn, Amy; Lecomte, Diane; Fiedler-Kelly, Jill; Damjanov, Nevena; Fishman, Mayer; Kane, Michael P; Rubin, Eric H; Tan, Antoinette R

    2008-09-15

    To evaluate the maximum tolerated dose (MTD), dose-limiting toxicities (DLT), and pharmacokinetics of liposome-entrapped paclitaxel easy-to-use (LEP-ETU) and to characterize the relationship between LEP-ETU concentrations and the time course of neutropenia in cancer patients. LEP-ETU was administered to 88 patients and 63 were evaluable for pharmacokinetic/pharmacodynamic (PK/PD) analysis following 1.5- and 3-h infusions every 3 weeks (q3w; dose range, 135-375 mg/m(2)). MTD was identified using a 3 + 3, up-and-down dose-finding algorithm. PK/PD modeling was done to describe the temporal relationship between paclitaxel concentrations and neutrophil count. Simulations assessed the influence of dose and schedule on neutropenia severity to help guide dose selection. The MTD of LEP-ETU was identified as 325 mg/m(2). DLTs occurring at 375 mg/m(2) consisted of febrile neutropenia and neuropathy. The C(max) and area under the plasma concentration-time curve of LEP-ETU were less than proportional with increasing dose. The PK/PD model showed that LEP-ETU inhibition of neutrophil proliferation was 9.1% per 10 mug/mL of total paclitaxel concentration. The incidence of grade 4 neutropenia increased from 33% to 42% across the dose range of 275 to 325 mg/m(2) q3w. For a dose of 110 mg/m(2) given weekly, grade 4 neutropenia was estimated to be 16% compared with 42% for the same total dose administered q3w. LEP-ETU can be administered safely at higher doses than Taxol. Modeling and simulation studies predict that 325 mg/m(2) LEP-ETU q3w provides acceptable neutropenic events relative to those observed at 175 mg/m(2) Taxol q3w. A 275 mg/m(2) dose may offer an improved therapeutic index.

  10. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaparpalvi, R; Mynampati, D; Kuo, H

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performedmore » using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm may very well be warranted.« less

  11. Medical Students' Perception of Their Educational Environment and Quality of Life: Is There a Positive Association?

    PubMed

    Enns, Sylvia Claassen; Perotta, Bruno; Paro, Helena B; Gannam, Silmar; Peleias, Munique; Mayer, Fernanda Brenneisen; Santos, Itamar Souza; Menezes, Marta; Senger, Maria Helena; Barelli, Cristiane; Silveira, Paulo S P; Martins, Milton A; Zen Tempski, Patricia

    2016-03-01

    To assess perceptions of educational environment of students from 22 Brazilian medical schools and to study the association between these perceptions and quality of life (QoL) measures. The authors performed a multicenter study (August 2011 to August 2012), examining students' views both of (1) educational environment using the Dundee Ready Education Environment Measure (DREEM) and (2) QoL using the World Health Organization Quality of Life Assessment, abbreviated version (WHOQOL-BREF). They also examined students' self-assessment of their overall QoL and medical-school-related QoL (MSQoL). The authors classified participants' perceptions into four quartiles according to DREEM total score, overall QoL, and MSQoL. Of 1,650 randomly selected students, 1,350 (81.8%) completed the study. The mean total DREEM score was 119.4 (standard deviation = 27.1). Higher total DREEM scores were associated with higher overall QoL and MSQoL scores (P < .001 for all comparisons) and younger ages (P < .001). Mean overall QoL scores were higher than MSQoL scores (mean difference, 1.35; 95% confidence interval [CI] 1.28-1.43; P < .001). Multinomial regression models showed significant dose-response patterns: Higher DREEM quartile scores were associated with better QoL. The psychological health domain of WHOQOL-BREF was most closely associated with DREEM scores (odds ratio 4.70; 95% CI = 3.80-5.81). The authors observed a positive association between QoL measures and DREEM scores. This association had a dose-response effect, independent of age, sex, and year of medical training, showing that educational environment appears to be an important moderator of medical student QoL.

  12. SU-E-T-611: Photon and Neutron Peripheral Dose Ratio for Low (6 MV) and High (15 MV) Energy for Treatment Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irazola, L; Sanchez-Doblado, F; Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville

    2015-06-15

    Purpose: Differences between radiotherapy techniques and energies, can offer improvements in tumor coverage and organs at risk preservation. However, a more complete decision should include peripheral doses delivered to the patient. The purpose of this work is the balance of photon and neutron peripheral doses for a prostate case solved with 6 different treatment modalities. Methods: Inverse and Forward IMRT and 3D-CRT in 6 and 15 MV for a Siemens Primus linac, using the same CT data set and contours. The methodology described in [1], was used with the TNRD thermal neutron detector [2] for neutron peripheral dose estimation atmore » 7 relevant organs (colon, esophagus, stomach, liver, lung, thyroid and skin). Photon doses were estimated for these organs by terms of the algorithm proposed in [3]. Plans were optimized with the same restrictions and limited to 30 segments in the Inverse case. Results: A similar photon peripheral dose was found comparing 6 and 15 MV cases with slightly higher values of (1.9 ± 1.6) % in mean, for the 6 MV cases. Neutron presence when using 15 MV, represents an increase in peripheral dose of (18 ± 17) % in average. Due to the higher number of MU used in Inverse IMRT, an increasing of (22 ± 3) % in neutron dose is found related to Forward and 3D-CRT plans. This corresponds to photon doses within 44 and 255 mSv along the organs, for a dose prescription of 68 Gy at the isocenter. Conclusion: Neutron and photon peripheral doses for a prostate treatment planified in 6 different techniques have been analyzed. 6 MV plans are slightly more demanding in terms of photon peripheral doses. Inverse technique in 15 MV has Result to be the most demanding one in terms of total peripheral doses, including neutrons and photons.« less

  13. Engineering cord blood to improve engraftment after cord blood transplant

    PubMed Central

    Dave, Hema; Bollard, Catherine M.; Shpall, Elizabeth J.

    2017-01-01

    Umbilical cord blood transplant (CBT) has traditionally been associated with slower engraftment of neutrophils, delayed immune reconstitution and consequently higher risk of infections as compared with peripheral blood progenitor cell (PBPC) or bone marrow (BM) transplants. This is primarily due to low numbers of total nucleated cells (TNCs) and the naive nature of CB immune cells. The use of double unit CB transplant (DCBT) increases the total cell dose in the graft, but it still does not produce as rapid engraftment as seen with PBPC or even BM transplants. Herein, we discuss strategies to improve engraftment after CBT. We describe methods of (I) expansion of CB graft ex vivo to increase the total cell dose; and (II) enhancement of BM homing capability of CB progenitor cells; (III) ex vivo expansion of CB derived T cells for improving T cell function against viruses, tumors and protection from graft versus host disease (GVHD). With these novel approaches, engraftment after CBT is now reaching levels comparable to that of other graft types. PMID:28607915

  14. Space Motion Sickness - Analysis of Medical Debriefs Data for Incidence and Treatment

    NASA Technical Reports Server (NTRS)

    Putcha, Lakshmi; Younker, D.; Daniels, V.

    2011-01-01

    Astronauts use medications for the treatment of a variety of illnesses during space travel. Data mining efforts to assess minor clinical conditions occurring during Shuttle flights STS-1 through STS-94 revealed that space motion sickness (SMS) was the most common ailment during early flight days, occurring in approx.40% of crewmembers, followed by digestive system disturbances (9%) and infectious diseases, which most commonly involved the respiratory or urinary tracts. A more recent analysis of postflight medical debriefs data to examine trends with respect to medication use by astronauts during spaceflights indicated that 37% of all prescriptions recorded was for pain followed by sleep (22%), SMS (18%), decongestion (14%), and all others (14%). Further analysis revealed that about 150 of 317 crewmembers experienced symptoms of SMS. Nearly all (132 of 150) crewmembers took medication for the treatment of symptoms with a total of 387 doses. Promethazine was taken most often (201 doses); in most cases this resulted in alleviation of symptoms with 130 crewmembers (65%) reporting feeling much or somewhat better. Although fewer total doses of the combination of promethazine and dextroamphetamine (Phen/Dex) were taken (45 doses), slightly more than half of these doses resulted in improvement. The combination of scopolamine and dextroamphetamine (Scop/Dex) was reported to be effective in only 37% of cases, with 36 of 97 total doses resulting in improvement. A higher percentage (24%) of Scop/Dex doses was reported to be ineffective compared with promethazine alone or as Phen/Dex (10% and 7%, respectively). Comparisons of the effectiveness of the different dosage forms of promethazine revealed that intramuscular injection was most effective in alleviating symptoms with 55% feeling much better, 16% feeling somewhat better, and only 7% feeling no effect or worse. Overall, it appears that promethazine alone was used more frequently during flight and was reported effective for the treatment of SMS.

  15. Effect of γ-irradiation on bioactivity, fatty acid compositions and volatile compounds of clary sage seed (Salvia sclarea L.).

    PubMed

    Yalcin, Hasan; Ozturk, Ismet; Tulukcu, Eray; Sagdic, Osman

    2011-09-01

    Clary sage seeds (Salvia sclarea L.) were obtained from plants cultivated, and 2.5, 4.0, 5.5, and 7.0 kGy doses of γ-irradiation were applied to the clary sage seeds. They were then analyzed for their protein, ash, oil and dry matter contents, and fatty acid composition. Additionally, the total phenolic contents, antiradical, antioxidant activities, and volatile compounds of the clary sage seed extract were determined. There was no significant difference in protein content. However, the moisture, oil, and ash contents of the samples were affected by irradiation. While the 7 kGy dose had a positive effect on the total phenolic content and antiradical activity of the sage seed extract, all doses have negative effects on the antioxidant activity of the sage seed. The main fatty acid of the sage seed was remarkably found as α-linolenic acid. The four irradiation levels caused significant differences in fatty acid composition by affecting all fatty acids except palmitic, palmitoleic, and eicosenoic acids. The dominant volatile compounds of control sage seed were found as β-pinene (18.81%) and limonene (15.60%). Higher doses of the irradiation decreased volatile components of sage seed. Clary sage seed including high omega-3 can be irradiated with low doses (≤ 2.5 kGy) of γ-irradiation. Clary sage is one of the most popular Salvia species in Turkey and many countries. Clary sage seed has approximately 29% oil content and this oil contains >50% of α-linolenic acid. γ-Irradiation is widely applied in the preservation of spice quality. The present study shows that the antioxidant activity of the clary sage seed is decreased by γ-irradiation. Additionally, higher doses of irradiation also decreased the volatile components of sage seed. Therefore, we suggest that clary sage seed which includes high levels of omega-3 should be irradiated with low doses (≤ 2.5 kGy) of γ-irradiation. © 2011 Institute of Food Technologists®

  16. Starting Dose of Sorafenib for the Treatment of Hepatocellular Carcinoma: A Retrospective, Multi-Institutional Study.

    PubMed

    Reiss, Kim A; Yu, Shun; Mamtani, Ronac; Mehta, Rajni; D'Addeo, Kathryn; Wileyto, E Paul; Taddei, Tamar H; Kaplan, David E

    2017-11-01

    Purpose Sorafenib is currently the only Food and Drug Administration-approved first-line therapy for patients with advanced hepatocellular carcinoma. There are few data examining how sorafenib starting dose may influence patient outcomes and costs. Patients and Methods We retrospectively evaluated 4,903 patients from 128 Veterans Health Administration hospitals who were prescribed sorafenib for hepatocellular carcinoma between January 2006 and April 2015. After 1:1 propensity score matching to account for potential treatment bias, hazard ratios (HRs) were calculated using Cox regression and were tested against a noninferiority margin of HR = 1.1. A matched multivariate logistic regression was performed to adjust for potential confounders. The primary end point was overall survival (OS) of patients who were prescribed standard starting dosage sorafenib (800 mg/d per os) versus that of patients who were prescribed reduced starting dose sorafenib (< 800 mg/d per os). Results There were 3,094 standard dose sorafenib patients (63%) and 1,809 reduced starting dose sorafenib patients (37%). Reduced starting dose sorafenib patients had more Barcelona Clinic Liver Cancer stage D ( P < .001), higher Model for End-Stage Liver Disease Sodium scores ( P < .001), higher Child-Turcotte-Pugh scores ( P < .001), and higher Cirrhosis Comorbidity Index scores ( P = .01). Consequently, reduced starting dose sorafenib patients had lower OS (median, 200 v 233 days, HR = 1.10). After propensity score matching and adjusting for potential confounders, there was no longer a significant OS difference (adjusted hazard ratio [HR adj ], 0.92; 95% CI, 0.83 to 1.01), and this fell significantly below the noninferiority margin ( P < .001). Reduced starting dose sorafenib patients experienced significantly lower total cumulative sorafenib cost and were less likely to discontinue sorafenib because of gastrointestinal adverse effects (8.7% v 10.8%; P = .047). Conclusion The initiation of sorafenib therapy at reduced dosages was associated with reduced pill burden, reduced treatment costs, and a trend toward a decreased rate of discontinuing sorafenib because of adverse events. Reduced dosing was not associated with inferior OS relative to standard dosing.

  17. Opioid doses required for pain management in lung cancer patients with different cholesterol levels: negative correlation between opioid doses and cholesterol levels.

    PubMed

    Huang, Zhenhua; Liang, Lining; Li, Lingyu; Xu, Miao; Li, Xiang; Sun, Hao; He, Songwei; Lin, Lilong; Zhang, Yixin; Song, Yancheng; Yang, Man; Luo, Yuling; Loh, Horace H; Law, Ping-Yee; Zheng, Dayong; Zheng, Hui

    2016-03-08

    Pain management has been considered as significant contributor to broad quality-of-life improvement for cancer patients. Modulating serum cholesterol levels affects analgesia abilities of opioids, important pain killer for cancer patients, in mice system. Thus the correlation between opioids usages and cholesterol levels were investigated in human patients with lung cancer. Medical records of 282 patients were selected with following criteria, 1) signed inform consent, 2) full medical records on total serum cholesterol levels and opioid administration, 3) opioid-naïve, 4) not received/receiving cancer-related or cholesterol lowering treatment, 5) pain level at level 5-8. The patients were divided into different groups basing on their gender and cholesterol levels. Since different opioids, morphine, oxycodone, and fentanyl, were all administrated at fixed low dose initially and increased gradually only if pain was not controlled, the percentages of patients in each group who did not respond to the initial doses of opioids and required higher doses for pain management were determined and compared. Patients with relative low cholesterol levels have larger percentage (11 out of 28 in female and 31 out of 71 in male) to not respond to the initial dose of opioids than those with high cholesterol levels (0 out of 258 in female and 8 out of 74 in male). Similar differences were obtained when patients with different opioids were analyzed separately. After converting the doses of different opioids to equivalent doses of oxycodone, significant correlation between opioid usages and cholesterol levels was also observed. Therefore, more attention should be taken to those cancer patients with low cholesterol levels because they may require higher doses of opioids as pain killer.

  18. Intra-articular versus intravenous tranexamic acid application in total knee arthroplasty: a meta-analysis of randomized controlled trials.

    PubMed

    Mi, Bobin; Liu, Guohui; Zhou, Wu; Lv, Huijuan; Liu, Yi; Zha, Kun; Wu, Qipeng; Liu, Jing

    2017-07-01

    The purpose of this meta-analysis was to compare the blood loss and complications of intra-articular (IA) with intravenous (IV) tranexamic acid (TXA) for total knee arthroplasty (TKA). A comprehensive search of studies was conducted to identify related articles in Pubmed, Embase, Cochrane central Register of Controlled Trials, springerLink, OVID and the Research published from January 1980 to September 2016. All studies that compared IA TXA with IV TXA application on TKA were included. Main outcomes of the two methods were collected and analyzed by using Review Manager 5.3. There were 16 randomized controlled trials with 1308 cases met the criteria. Compared with IV TXA, IA TXA had similar blood volume of drainage, hidden blood loss, transfusion rate and complications (P > 0.05). IA TXA had lower total blood loss than IV TXA, and there was significant difference (P < 0.05). Subgroup analysis of total blood loss based on times of IV TXA administration showed that repeat dose of IV TXA had a higher total blood loss and postoperative hemoglobin drop (P < 0.05) than IA TXA. However, single dose of IV TXA had a similar efficacy on total blood loss and postoperative hemoglobin drop (P > 0.05) when compared with IA TXA. Both IA TXA and single dose of IV TXA are effective in reducing total blood loss and postoperative hemoglobin drop without increasing complications of DVT or PE. The current meta-analysis suggests that 1.5 g TXA by IA administration or 1 g TXA by IV administration 10 min before tourniquet deflation is effective and safe in patients undergoing TKA.

  19. Higher parity is associated with increased risk of Type 2 diabetes mellitus in women: A linear dose-response meta-analysis of cohort studies.

    PubMed

    Guo, Peng; Zhou, Quan; Ren, Lei; Chen, Yu; Hui, Yue

    2017-01-01

    The goal of this study is to investigate the association between higher parity and the risk of occurrence of type 2 diabetes mellitus (T2DM) in women and to quantify the potential dose-response relation. We searched MEDLINE, and EMBASE electronic databases for related cohort studies up to March 10th, 2016. Summary rate ratios (RRs) and 95% confidence intervals (CIs) for T2DM with at least 3 categories of exposure were eligible. A random-effects dose-response analysis procedure was used to study the relations between them. After screening a total of 13,647 published studies, only 7 cohort studies (9,394 incident cases and 286,840 female participants) were found to be eligible for this meta-analysis. In the category analysis, the pooled RR for the highest number of parity vs. the lowest one was 1.42 (95% CI: 1.17-1.72, I 2 =71.5%, P heterogeneity =0.002, Power=0.99). In the dose-response analysis, a noticeable linear dose-risk relation was found between parity and T2DM (P for nonlinearity test =0.942). For every live birth increase in parity, the combined RR was 1.06 (95% CI: 1.02-1.09, I 2 =84.3%, P heterogeneity =0.003, Power=0.99). Subgroup and sensitivity analyses yielded similar results. No publication bias was found in the results. This meta-analysis suggests that higher parity and the risk of T2DM show a linear relationship in women. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. SU-G-206-05: A Comparison of Head Phantoms Used for Dose Determination in Imaging Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, Z; Vijayan, S; Kilian-Meneghin, J

    Purpose: To determine similarities and differences between various head phantoms that might be used for dose measurements in diagnostic imaging procedures. Methods: We chose four frequently used anthropomorphic head phantoms (SK-150, PBU-50, RS-240T and Alderson Rando), a computational patient phantom (Zubal) and the CTDI head phantom for comparison in our study. We did a CT scan of the head phantoms using the same protocol and compared their dimensions and CT numbers. The scan data was used to calculate dose values for each of the phantoms using EGSnrc Monte Carlo software. An .egsphant file was constructed to describe these phantoms usingmore » a Visual C++ program for DOSXYZnrc/EGSnrc simulation. The lens dose was calculated for a simulated CBCT scan using DOSXYZnrc/EGSnrc and the calculated doses were validated with measurements using Gafchromic film and an ionization chamber. Similar calculations and measurements were made for PA radiography to investigate the attenuation and backscatter differences between these phantoms. We used the Zubal phantom as the standard for comparison since it was developed based on a CT scan of a patient. Results: The lens dose for the Alderson Rando phantom is around 9% different than the Zubal phantom, while the lens dose for the PBU-50 phantom was about 50% higher, possibly because its skull thickness and the density of bone and soft tissue are lower than anthropometric values. The lens dose for the CTDI phantom is about 500% higher because of its totally different structure. The entrance dose profiles are similar for the five anthropomorphic phantoms, while that for the CTDI phantom was distinctly different. Conclusion: The CTDI and PBU-50 head phantoms have substantially larger lens dose estimates in CBCT. The other four head phantoms have similar entrance dose with backscatter hence should be preferred for dose measurement in imaging procedures of the head. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less

  1. Risk of Injection-Site Abscess among Infants Receiving a Preservative-Free, Two-Dose Vial Formulation of Pneumococcal Conjugate Vaccine in Kenya

    PubMed Central

    Burton, Deron C.; Bigogo, Godfrey M.; Audi, Allan O.; Williamson, John; Munge, Kenneth; Wafula, Jackline; Ouma, Dominic; Khagayi, Sammy; Mugoya, Isaac; Mburu, James; Muema, Shadrack; Bauni, Evasius; Bwanaali, Tahreni; Feikin, Daniel R.; Ochieng, Peter M.; Mogeni, Ondari D.; Otieno, George A.; Olack, Beatrice; Kamau, Tatu; Van Dyke, Melissa K.; Chen, Robert; Farrington, Paddy; Montgomery, Joel M.; Breiman, Robert F.; Scott, J. Anthony G.; Laserson, Kayla F.

    2015-01-01

    There is a theoretical risk of adverse events following immunization with a preservative-free, 2-dose vial formulation of 10-valent-pneumococcal conjugate vaccine (PCV10). We set out to measure this risk. Four population-based surveillance sites in Kenya (total annual birth cohort of 11,500 infants) were used to conduct a 2-year post-introduction vaccine safety study of PCV10. Injection-site abscesses occurring within 7 days following vaccine administration were clinically diagnosed in all study sites (passive facility-based surveillance) and, also, detected by caregiver-reported symptoms of swelling plus discharge in two sites (active household-based surveillance). Abscess risk was expressed as the number of abscesses per 100,000 injections and was compared for the second vs first vial dose of PCV10 and for PCV10 vs pentavalent vaccine (comparator). A total of 58,288 PCV10 injections were recorded, including 24,054 and 19,702 identified as first and second vial doses, respectively (14,532 unknown vial dose). The risk ratio for abscess following injection with the second (41 per 100,000) vs first (33 per 100,000) vial dose of PCV10 was 1.22 (95% confidence interval [CI] 0.37–4.06). The comparator vaccine was changed from a 2-dose to 10-dose presentation midway through the study. The matched odds ratios for abscess following PCV10 were 1.00 (95% CI 0.12–8.56) and 0.27 (95% CI 0.14–0.54) when compared to the 2-dose and 10-dose pentavalent vaccine presentations, respectively. In Kenya immunization with PCV10 was not associated with an increased risk of injection site abscess, providing confidence that the vaccine may be safely used in Africa. The relatively higher risk of abscess following the 10-dose presentation of pentavalent vaccine merits further study. PMID:26509274

  2. Risk of Injection-Site Abscess among Infants Receiving a Preservative-Free, Two-Dose Vial Formulation of Pneumococcal Conjugate Vaccine in Kenya.

    PubMed

    Burton, Deron C; Bigogo, Godfrey M; Audi, Allan O; Williamson, John; Munge, Kenneth; Wafula, Jackline; Ouma, Dominic; Khagayi, Sammy; Mugoya, Isaac; Mburu, James; Muema, Shadrack; Bauni, Evasius; Bwanaali, Tahreni; Feikin, Daniel R; Ochieng, Peter M; Mogeni, Ondari D; Otieno, George A; Olack, Beatrice; Kamau, Tatu; Van Dyke, Melissa K; Chen, Robert; Farrington, Paddy; Montgomery, Joel M; Breiman, Robert F; Scott, J Anthony G; Laserson, Kayla F

    2015-01-01

    There is a theoretical risk of adverse events following immunization with a preservative-free, 2-dose vial formulation of 10-valent-pneumococcal conjugate vaccine (PCV10). We set out to measure this risk. Four population-based surveillance sites in Kenya (total annual birth cohort of 11,500 infants) were used to conduct a 2-year post-introduction vaccine safety study of PCV10. Injection-site abscesses occurring within 7 days following vaccine administration were clinically diagnosed in all study sites (passive facility-based surveillance) and, also, detected by caregiver-reported symptoms of swelling plus discharge in two sites (active household-based surveillance). Abscess risk was expressed as the number of abscesses per 100,000 injections and was compared for the second vs first vial dose of PCV10 and for PCV10 vs pentavalent vaccine (comparator). A total of 58,288 PCV10 injections were recorded, including 24,054 and 19,702 identified as first and second vial doses, respectively (14,532 unknown vial dose). The risk ratio for abscess following injection with the second (41 per 100,000) vs first (33 per 100,000) vial dose of PCV10 was 1.22 (95% confidence interval [CI] 0.37-4.06). The comparator vaccine was changed from a 2-dose to 10-dose presentation midway through the study. The matched odds ratios for abscess following PCV10 were 1.00 (95% CI 0.12-8.56) and 0.27 (95% CI 0.14-0.54) when compared to the 2-dose and 10-dose pentavalent vaccine presentations, respectively. In Kenya immunization with PCV10 was not associated with an increased risk of injection site abscess, providing confidence that the vaccine may be safely used in Africa. The relatively higher risk of abscess following the 10-dose presentation of pentavalent vaccine merits further study.

  3. Real-World Data Collection Regarding Titration Algorithms for Insulin Glargine in Patients With Type 2 Diabetes Mellitus

    PubMed Central

    Pfützner, Andreas; Stratmann, Bernd; Funke, Klaus; Pohlmeier, Harald; Rose, Ludger; Sieber, Jochen; Flacke, Frank; Tschoepe, Diethelm

    2016-01-01

    The primary objective of this study was to collect data regarding the effectiveness of different dose titration algorithms (TAs) for optimization or initiation of basal insulin supported oral therapy (BOT) in patients with type 2 diabetes. A total of 50 patients were enrolled in this trial (17 women, 33 men, age 63 ± 8 years, HbA1c 7.9 ± 0.8%). The investigator decided on an individual basis to apply any of 4 standard TAs: standard (S: fasting glucose target 90-130 mg/dL, n = 39), standard-fast titration (S-FT: 90-130 mg/dL, larger dose increments at FBG < 180 mg/dl, n = 1), less tight (LT: 110-150 mg/dL, n = 5), and tight (T: 70-100 mg/dL, n = 5). During the next 30 days daily contacts were used to adapt the insulin dose. The majority of all patients (70%) achieved a stable insulin glargine dose within 5 ± 6 days after initiation of the dose titration. HbA1c improved from 7.9 ± 0.8% to 7.5 ± 0.7% (P < .001). In total, 1300 dose decisions were made (1192 according to the TA and 108 by the physicians independently from the TA in 29 patients [58% of study population]). Reasons for TA-overruling dosing decisions were hypoglycemic events (14 mild/4 moderate) in 9 patients. In the majority of these cases (89.8%), the physician recommended continuation of the previous dose or a higher dose. The majority of FBG values were within the respective target range after 4 weeks. In conclusion, the insulin glargine TAs delivered safe dose recommendations with a low risk of hypoglycemia, which successfully led to a stable dose in the vast majority of patients. PMID:27325389

  4. Radiotherapy boost dose-escalation for invasive breast cancer after breast-conserving surgery: 2093 patients treated with a prospective margin-directed policy.

    PubMed

    Livi, Lorenzo; Meattini, Icro; Franceschini, Davide; Saieva, Calogero; Meacci, Fiammetta; Marrazzo, Livia; Gerlain, Elena; Desideri, Isacco; Scotti, Vieri; Nori, Jacopo; Sanchez, Luis Jose; Orzalesi, Lorenzo; Bonomo, Pierluigi; Greto, Daniela; Bianchi, Simonetta; Biti, Giampaolo

    2013-08-01

    To investigate the outcome of invasive early breast cancer patients that underwent breast-conserving surgery and adjuvant radiotherapy (RT), treated with a prospective margin-directed institutional policy for RT boost dose, based on final margins status (FMS). A total of 2093 patients were treated between 2000 and 2008. 10 Gy boost was prescribed in case of FMS>5mm; 16 Gy boost with FMS between 2 and 5mm; 20 Gy boost in case of FMS<2mm or positive. After a median follow up of 5.2 years, we recorded 41 local relapse (LR, 2%). Concerning LR free survival, age at diagnosis, nuclear grade, hormonal status, T-stage, adjuvant hormonal therapy and adjuvant chemotherapy emerged as significant parameters (p-values from log rank test <0.05). FMS, that directed the RT boost dose, did not have significant impact on LRFS (p=0.46). LR rates were 2.3% for FMS<2mm, 2.6% for 2-5mm FMS and 1.8% for FMS>5mm. At multivariate analysis, higher nuclear grade (p=0.045), triple negative subtype (p=0.036) and higher T-stage (p=0.02) resulted as the independent predictors of LR occurrence. Our experience showed that a margin-directed policy of RT boost dose-escalation seems to reduce the negative impact of FMS on LR, but it is not able to overcome the unfavorable effect of higher nuclear grade, higher T stage and triple negative subtype. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Plasma, salivary and urinary cortisol levels following physiological and stress doses of hydrocortisone in normal volunteers.

    PubMed

    Jung, Caroline; Greco, Santo; Nguyen, Hanh H T; Ho, Jui T; Lewis, John G; Torpy, David J; Inder, Warrick J

    2014-11-26

    Glucocorticoid replacement is essential in patients with primary and secondary adrenal insufficiency, but many patients remain on higher than recommended dose regimens. There is no uniformly accepted method to monitor the dose in individual patients. We have compared cortisol concentrations in plasma, saliva and urine achieved following "physiological" and "stress" doses of hydrocortisone as potential methods for monitoring glucocorticoid replacement. Cortisol profiles were measured in plasma, saliva and urine following "physiological" (20 mg oral) or "stress" (50 mg intravenous) doses of hydrocortisone in dexamethasone-suppressed healthy subjects (8 in each group), compared to endogenous cortisol levels (12 subjects). Total plasma cortisol was measured half-hourly, and salivary cortisol and urinary cortisol:creatinine ratio were measured hourly from time 0 (between 0830 and 0900) to 5 h. Endogenous plasma corticosteroid-binding globulin (CBG) levels were measured at time 0 and 5 h, and hourly from time 0 to 5 h following administration of oral or intravenous hydrocortisone. Plasma free cortisol was calculated using Coolens' equation. Plasma, salivary and urine cortisol at 2 h after oral hydrocortisone gave a good indication of peak cortisol concentrations, which were uniformly supraphysiological. Intravenous hydrocortisone administration achieved very high 30 minute cortisol concentrations. Total plasma cortisol correlated significantly with both saliva and urine cortisol after oral and intravenous hydrocortisone (P <0.0001, correlation coefficient between 0.61 and 0.94). There was no difference in CBG levels across the sampling period. An oral dose of hydrocortisone 20 mg is supraphysiological for routine maintenance, while stress doses above 50 mg 6-hourly would rarely be necessary in managing acute illness. Salivary cortisol and urinary cortisol:creatinine ratio may provide useful alternatives to plasma cortisol measurements to monitor replacement doses in hypoadrenal patients.

  6. External beam radiotherapy for palliation of painful bone metastases: pooled data bioeffect dose response analysis of dose fractionation

    NASA Astrophysics Data System (ADS)

    Naveen, T.; Supe, Sanjay S.; Ganesh, K. M.; Samuel, Jacob

    2009-01-01

    Bone metastases develop in up to 70% of newly diagnosed cancer patients and result in immobility, anxiety, and depression, severely diminishing the patients quality of life. Radiotherapy is a frequently used modality for bone metastasis and has been shown to be effective in reducing metastatic bone pain and in some instances, causing tumor shrinkage or growth inhibition. There is controversy surrounding the optimal fractionation schedule and total dose of external beam radiotherapy, despite many randomized trials and overviews addressing the issue. This study was undertaken to apply BED to clinical fractionation data of radiotherapeutic management of bone metastases in order to arrive at optimum BED values for acceptable level of response rate. A computerised literature search was conducted to identify all prospective clinical studies that addressed the issue of fractionation for the treatment of bone metastasis. The results of these studies were pooled together to form the database for the analysis. A total of 4111 number of patients received radiation dose ranging from 4 to 40.5 Gy in 1 to 15 fractions with dose per fraction ranging from 2 to 10 Gy. Single fraction treatments were delivered in 2013 patients and the dose varied from 4 to 10 Gy. Multifraction treatments were delivered in 2098 patients and the dose varied from 15 to 40.5 Gy. The biological effective dose (BED) was evaluated for each fractionation schedule using the linear quadratic model and an α/β value of 10 Gy. Response rate increased significantly beyond a BED value of 14.4 Gy (p < 0.01). Based on our analysis and indications from the literature about higher retreatment and fracture rate of single fraction treatments, minimum BED value of 14.4 Gy is recommended.

  7. Gamma Radiation Dose Rate in Air due to Terrestrial Radionuclides in Southern Brazil: Synthesis by Geological Units and Lithotypes Covered by the Serra do Mar Sul Aero-Geophysical Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bastos, Rodrigo O.; Appoloni, Carlos R.; Pinese, Jose P. P.

    2008-08-07

    The absorbed dose rates in air due to terrestrial radionuclides were estimated from aerial gamma spectrometric data for an area of 48,600 km{sup 2} in Southern Brazil. The source data was the Serra do Mar Sul Aero-Geophysical Project back-calibrated in a cooperative work among the Geological Survey of Brazil, the Geological Survey of Canada, and Paterson, Grant and Watson Ltd. The concentrations of eU (ppm), eTh (ppm) and K (%) were converted to dose rates in air (nGy{center_dot}h{sup -1}) by accounting for the contribution of each element's concentration. Regional variation was interpreted according to lithotypes and a synthesis was performedmore » according to the basic geological units present in the area. Higher values of total dose were estimated for felsic igneous and metamorphic rocks, with average values varying up to 119{+-}24 nGy{center_dot}h{sup -1}, obtained by Anitapolis syenite body. Sedimentary, metasedimentary and metamafic rocks presented the lower dose levels, and some beach deposits reached the lowest average total dose, 18.5{+-}8.2 nGy{center_dot}h{sup -1}. Thorium gives the main average contribution in all geological units, the highest value being reached by the nebulitic gneisses of Atuba Complex, 71{+-}23 nGy{center_dot}h{sup -1}. Potassium presents the lowest average contribution to dose rate in 53 of the 72 units analyzed, the highest contribution being obtained by intrusive alkaline bodies (28{+-}12 nGy{center_dot}h{sup -1}). The general pattern of geographic dose distribution respects well the hypotheses on geo-physicochemical behavior of radioactive elements.« less

  8. Tetrahydrocannabinol-induced suppression of macrophage spreading and phagocytic activity in vitro.

    PubMed

    Lopez-Cepero, M; Friedman, M; Klein, T; Friedman, H

    1986-06-01

    The effects of tetrahydrocannabinol (THC) on several parameters of macrophage function in vitro were assessed. Delta 9 THC added to cultures of normal mouse peritoneal cells in vitro affected the ability of the cells to spread on glass surfaces and also had some effect on their ability to phagocytize yeast. These effects were dose related. A concentration of 20 micrograms of THC almost completely inhibited macrophage spreading, but it also decreased viability and the total number of these cells. Doses of 10 or 5 micrograms of THC also inhibited spreading but had little effect on cell viability or number. A dose of 1.0 microgram of THC had some inhibitory effect on spreading and the lowest dose affecting spreading appeared to be about 0.05 micrograms per culture. Higher doses of THC were necessary to inhibit phagocytosis of yeast particles as determined by direct microscopic examination or use of radiolabeled yeast as the test particles. These results indicate that several readily measured functions of macrophages may be suppressed by THC.

  9. Sodium Iodate Selectively Injuries the Posterior Pole of the Retina in a Dose-Dependent Manner: Morphological and Electrophysiological Study

    PubMed Central

    Machalińska, Anna; Lubiński, Wojciech; Kłos, Patrycja; Kawa, Miłosz; Baumert, Bartłomiej; Penkala, Krzysztof; Grzegrzółka, Ryszard; Karczewicz, Danuta; Wiszniewska, Barbara

    2010-01-01

    Sequential morphological and functional features of retinal damage in mice exposed to different doses (40 vs. 20 mg/kg) of sodium iodate (NaIO3) were analyzed. Retinal morphology, apoptosis (TUNEL assay), and function (electroretinography; ERG) were examined at several time points after NaIO3 administration. The higher dose of NaIO3 caused progressive degeneration of the whole retinal area and total suppression of scotopic and photopic ERG. In contrast, the lower dose induced much less severe degeneration in peripheral part of retina along with a moderate decline of b- and a-wave amplitudes in ERG, corroborating the presence of regions within retina that retain their function. The peak of photoreceptor apoptosis was found on the 3rd day, but the lower dose induced more intense reaction within the central retina than in its peripheral region. In conclusion, these results indicate that peripheral area of the retina reveals better resistance to NaIO3 injury than its central part. PMID:20725778

  10. Pharmacokinetic and pharmacodynamic modeling to determine the dose of ST-246 to protect against smallpox in humans.

    PubMed

    Leeds, Janet M; Fenneteau, Frederique; Gosselin, Nathalie H; Mouksassi, Mohamad-Samer; Kassir, Nastya; Marier, J F; Chen, Yali; Grosenbach, Doug; Frimm, Annie E; Honeychurch, Kady M; Chinsangaram, Jarasvech; Tyavanagimatt, Shanthakumar R; Hruby, Dennis E; Jordan, Robert

    2013-03-01

    Although smallpox has been eradicated, the United States government considers it a "material threat" and has funded the discovery and development of potential therapeutic compounds. As reported here, the human efficacious dose for one of these compounds, ST-246, was determined using efficacy studies in nonhuman primates (NHPs), together with pharmacokinetic and pharmacodynamic analysis that predicted the appropriate dose and exposure levels to provide therapeutic benefit in humans. The efficacy analysis combined the data from studies conducted at three separate facilities that evaluated treatment following infection with a closely related virus, monkeypox virus (MPXV), in a total of 96 NHPs. The effect of infection on ST-246 pharmacokinetics in NHPs was applied to humans using population pharmacokinetic models. Exposure at the selected human dose of 600 mg is more than 4-fold higher than the lowest efficacious dose in NHPs and is predicted to provide protection to more than 95% of the population.

  11. Acute Toxicity Study of Zerumbone-Loaded Nanostructured Lipid Carrier on BALB/c Mice Model

    PubMed Central

    Rahman, Heshu Sulaiman; Rasedee, Abdullah; Othman, Hemn Hassan; Chartrand, Max Stanley; Namvar, Farideh; Abdul Samad, Nozlena; Andas, Reena Joys; Ng, Kuan Beng; How, Chee Wun

    2014-01-01

    Zerumbone- (ZER-) loaded nanostructure lipid carrier (NLC) (ZER-NLC) prepared for its antileukemia effect in vitro was evaluated for its toxicological effects by observing changes in the liver, kidney, spleen, lung, heart, and brain tissues, serum biochemical parameters, total haemogram, and bone marrow stem cells. The acute toxicity study for ZER-NLC was conducted by orally treating BALB/c mice with a single dose with either water, olive oil, ZER, NLC, or ZER-NLC for 14 days. The animals were observed for clinical and behavioral abnormalities, toxicological symptoms, feed consumption, and gross appearance. The liver, kidney, heart, lung, spleen, and brain tissues were assessed histologically. Total haemogram was counted by hemocytometry and microhematocrit reader. Bone marrow examination in terms of cellular morphology was done by Wright staining with bone marrow smear. Furthermore, serum biochemical parameters were determined spectrophotometrically. Grossly all treated mice, their investigated tissues, serum biochemical parameters, total haemogram, and bone marrow were normal. At oral doses of 100 and 200 mg/kg ZER-NLC there was no sign of toxicity or mortality in BALB/c mice. This study suggests that the 50% lethal dose (LD50) of ZER-NLC is higher than 200 mg/kg, thus, safe by oral administration. PMID:25276798

  12. Acute toxicity study of zerumbone-loaded nanostructured lipid carrier on BALB/c mice model.

    PubMed

    Rahman, Heshu Sulaiman; Rasedee, Abdullah; Othman, Hemn Hassan; Chartrand, Max Stanley; Namvar, Farideh; Yeap, Swee Keong; Abdul Samad, Nozlena; Andas, Reena Joys; Muhammad Nadzri, Nabilah; Anasamy, Theebaa; Ng, Kuan Beng; How, Chee Wun

    2014-01-01

    Zerumbone- (ZER-) loaded nanostructure lipid carrier (NLC) (ZER-NLC) prepared for its antileukemia effect in vitro was evaluated for its toxicological effects by observing changes in the liver, kidney, spleen, lung, heart, and brain tissues, serum biochemical parameters, total haemogram, and bone marrow stem cells. The acute toxicity study for ZER-NLC was conducted by orally treating BALB/c mice with a single dose with either water, olive oil, ZER, NLC, or ZER-NLC for 14 days. The animals were observed for clinical and behavioral abnormalities, toxicological symptoms, feed consumption, and gross appearance. The liver, kidney, heart, lung, spleen, and brain tissues were assessed histologically. Total haemogram was counted by hemocytometry and microhematocrit reader. Bone marrow examination in terms of cellular morphology was done by Wright staining with bone marrow smear. Furthermore, serum biochemical parameters were determined spectrophotometrically. Grossly all treated mice, their investigated tissues, serum biochemical parameters, total haemogram, and bone marrow were normal. At oral doses of 100 and 200 mg/kg ZER-NLC there was no sign of toxicity or mortality in BALB/c mice. This study suggests that the 50% lethal dose (LD50) of ZER-NLC is higher than 200 mg/kg, thus, safe by oral administration.

  13. Phenytoin kinetics during pregnancy and the puerperium.

    PubMed

    Knott, C; Williams, C P; Reynolds, F

    1986-10-01

    During pregnancy changes in maternal physiology and plasma composition may alter drug binding and dose requirements. We have measured plasma unbound and total phenytoin, and saliva concentrations at intervals in 11 pregnant epileptics. Plasma albumin concentrations were also measured in pregnant and non-pregnant women. Saliva phenytoin correlated closely with the plasma unbound concentrations (r = 0.98). The saliva:plasma (S:P) ratio, reflecting the free fraction, was variable during pregnancy but tended to increase to maximal values at delivery and return to non-pregnant values within 2-8 weeks thereafter. Plasma albumin concentrations correlated poorly with phenytoin binding. Binding in umbilical cord plasma appeared higher than that in maternal plasma and total fetal concentrations correlated closely with maternal plasma concentrations at delivery. No ill effects of phenytoin were detected in the newborn infant. During the third trimester phenytoin dose increments were necessary to maintain therapeutic concentrations. After delivery maternal saliva phenytoin concentrations rose, and dose reductions were necessary to avoid clinical symptoms of toxicity. It is therefore appropriate to monitor saliva phenytoin concentrations regularly both during pregnancy and the puerperium.

  14. First-in-human study of the toxicity, pharmacokinetics, and pharmacodynamics of CG200745, a pan-HDAC inhibitor, in patients with refractory solid malignancies.

    PubMed

    Kim, Kyu-pyo; Park, Seong Joon; Kim, Jeong-Eun; Hong, Yong Sang; Lee, Jae-Lyun; Bae, Kyun-Seop; Cha, Hyunju; Kwon, Sool-Ki; Ro, Seonggu; Cho, JoongMyung; Kim, Tae Won

    2015-10-01

    The aim of the present study was to assess the safety, maximum tolerated dose (MTD), pharmacokinetics, pharmacodynamics, and efficacy of single and multiple doses of intravenous CG200745, a novel histone deacetylase (HDAC) inhibitor, in patients with advanced solid malignancies. Two to six patients received intravenous CG200745 according to the 2 + 4 dose-escalating method. This first-in-human trial was comprised of two parts: Part 1 was a single ascending dose, and Part 2 was multiple ascending doses weekly for 3 weeks, and then 1 week off. For the first cycle, pharmacokinetic sampling for CG200745 and pharmacodynamic sampling for acetylated histone H4 in peripheral blood mononuclear cells (PBMCs) were performed on day 1 for Part 1 and on days 1 and 15 for Part 2. Examination of acetylated histone H4 in pre- and post-biopsy samples was performed in accessible patients. In all, 28 patients were treated at 13 dose levels (1.8-250 mg/m(2)) and received a total of 71 cycles of CG200745. Hematologic toxicities included grade 3/4 neutropenia (22.2 %) that did not last a week and non-hematologic toxicities included fatigue (22.2 %) and anorexia (16.7 %) that did not exceed grade 2. No dose-limiting toxic effects were noted. Dose proportionality was observed for both the maximum concentration and area under the curve. The elimination half-life was 5.67 ± 2.69 h (mean ± standard deviation). An increase in PBMC acetylated histone H4 was observed at dose levels up to 51 mg/m(2), which plateaued at higher dose levels. At 24 h, 75 % of patients (6/8) showed higher relative acetylation in tumor tissue compared to PBMCs. Although there was no partial or complete response, 57.1 % of patients (16/28) had stable disease that lasted at least 6 weeks. CG200745 can be safely administered at effective dose levels that inhibit HDAC in PBMCs and tumor tissue. Although MTD was not reached, further escalation was not performed because acetylated histone H4 plateaued at dose levels higher than 51 mg/m(2). Additional phase II trials are recommended at 250 mg/m(2).

  15. Older adults and high-risk medication administration in the emergency department

    PubMed Central

    Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J

    2017-01-01

    Background Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). Patients and methods ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated (“High doses” were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; “very high doses” were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65–69, 70–74, 75–79, 80–84, and ≥85 years), gender, and hospital. Results There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65–69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56–11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69–18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26–1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07–2.16). Conclusion Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65–69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted. PMID:29184448

  16. Outcomes of peripheral blood stem cell transplantation patients from HLA-mismatched unrelated donor with antithymocyte globulin (ATG)-Thymoglobulin versus ATG-Fresenius: a single-center study.

    PubMed

    Huang, Wenrong; Zhao, Xiaoli; Tian, Yamin; Cao, Tingting; Li, Yanfen; Liu, Zhanxiang; Jing, Yu; Wang, Shuhong; Gao, Chunji; Yu, Li

    2015-02-01

    Although antithymocyte globulin (ATG) had been widely used in hematopoietic stem cell transplantation from unrelated donor due to its ability to prevent acute and chronic graft-versus-host disease (GVHD), the comparative efficacy and safety of ATG-Thymoglobulin (ATG-T) and ATG-Fresenius (ATG-F) in patients undergoing HLA-mismatched allogeneic peripheral blood stem cell transplantation from unrelated donors (UR-PBSCT) has not been evaluated. Retrospective analysis of patients who underwent HLA-mismatched UR-PBSCT between January 2003 and December 2013 and received pre-transplant ATG-T at a total dose of 10 mg/kg or ATG-F at a total dose of 20 mg/kg was performed. Patients who received ATG-T (n = 23) or ATG-F (n = 28) had similar baseline demographic, disease, and transplant characteristics. There were no significant between-groups differences in the probability of acute GVHD (P = 0.721) and chronic GVHD (P = 0.439). ATG-F was associated with nonsignificant trends toward higher disease-free survival at 3-year follow-up compared with ATG-T (45.7 ± 11.1 vs 61.3 ± 9.7 %, respectively, P = 0.07). A significantly greater proportion of ATG-T patients experienced high fever than ATG-F patients (P < 0.01) during ATG infusion. There was no difference in the rate of infection between the two treatment groups. There were less adverse effects comparing ATG-F with ATG-T. ATG-T at a total dose of 10 mg/kg and ATG-F at a total dose of 20 mg/kg had a similar clinical outcome in the setting of HLA-mismatched UR-PBSCT.

  17. Higher convection volume exchange with online hemodiafiltration is associated with survival advantage for dialysis patients: the effect of adjustment for body size.

    PubMed

    Davenport, Andrew; Peters, Sanne A E; Bots, Michiel L; Canaud, Bernard; Grooteman, Muriel P C; Asci, Gulay; Locatelli, Francesco; Maduell, Francisco; Morena, Marion; Nubé, Menso J; Ok, Ercan; Torres, Ferran; Woodward, Mark; Blankestijn, Peter J

    2016-01-01

    Mortality remains high for hemodialysis patients. Online hemodiafiltration (OL-HDF) removes more middle-sized uremic toxins but outcomes of individual trials comparing OL-HDF with hemodialysis have been discrepant. Secondary analyses reported higher convective volumes, easier to achieve in larger patients, and improved survival. Here we tested different methods to standardize OL-HDF convection volume on all-cause and cardiovascular mortality compared with hemodialysis. Pooled individual patient analysis of four prospective trials compared thirds of delivered convection volume with hemodialysis. Convection volumes were either not standardized or standardized to weight, body mass index, body surface area, and total body water. Data were analyzed by multivariable Cox proportional hazards modeling from 2793 patients. All-cause mortality was reduced when the convective dose was unstandardized or standardized to body surface area and total body water; hazard ratio (95% confidence intervals) of 0.65 (0.51-0.82), 0.74 (0.58-0.93), and 0.71 (0.56-0.93) for those receiving higher convective doses. Standardization by body weight or body mass index gave no significant survival advantage. Higher convection volumes were generally associated with greater survival benefit with OL-HDF, but results varied across different ways of standardization for body size. Thus, further studies should take body size into account when evaluating the impact of delivered convection volume on mortality end points. Copyright © 2015 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  18. Maternal characteristics and hospital policies as risk factors for nonreceipt of hepatitis B vaccine in the newborn nursery.

    PubMed

    O'Leary, Sean T; Nelson, Christina; Duran, Julie

    2012-01-01

    A birth dose of hepatitis B vaccine (HBV) is a primary focus of the Advisory Committee on Immunization Practices' strategy to eliminate transmission of hepatitis B virus in the United States. We sought to assess the impact of maternal characteristics and hospital policy on the receipt of a birth dose of HBV. A retrospective cohort study was performed using data from the 2008 Colorado birth registry. Hospital policy was assessed by state health department personnel. Univariate and multivariate logistic regression analyses were used to examine the association of maternal characteristics and hospital policy with nonreceipt of HBV. A total of 64,425 infants were identified in the birth cohort, of whom 61.6% received a birth dose of HBV. Higher maternal education and income were associated with nonreceipt of HBV (master's degree vs. eighth grade or less: adjusted odds ratio [OR] = 1.66, 95% confidence interval [CI] = 1.49-1.85; >$75,000 vs. <$15,000: adjusted OR = 1.21, 95% CI = 1.13-1.30). Lack of a hospital policy stipulating a universal birth dose strongly predicted nonreceipt of a birth dose of HBV (policy with no birth dose vs. policy with a birth dose: adjusted OR = 2.21, 95% CI = 2.13-2.30). Maternal characteristics such as higher education and income are associated with nonreceipt of the HBV during the perinatal period. To effectively reduce risk of perinatal hepatitis B transmission, hospitals should stipulate that all infants are offered HBV and ensure that these policies are implemented and followed.

  19. Dose-dependent efficacy of the Vitex agnus castus extract Ze 440 in patients suffering from premenstrual syndrome.

    PubMed

    Schellenberg, Ruediger; Zimmermann, Christian; Drewe, Jürgen; Hoexter, Godehard; Zahner, Catherine

    2012-11-15

    Preparations of Vitex agnus castus L. (VAC) have been shown to be effective to treat irregular menstrual cycles, cyclical mastalgia and symptoms of the premenstrual syndrome (PMS). However, the dose-effect relationship for the treatment of PMS has not yet been established. This study aimed to investigate the clinical effects of three different doses of the VAC extract Ze 440 in comparison to placebo in patients suffering from PMS. In a multicenter, double-blind, placebo-controlled, parallel-group study, 162 female patients with PMS (18-45 years) were randomized to either placebo or different doses of Ze 440 (8, 20 and 30 mg) over three menstrual cycles. PMS symptoms' severity was assessed by patients using visual analog scales (VAS) for the symptoms irritability, mood alteration, anger, headache, bloating and breast fullness. Each of the treatments was well tolerated. Improvement in the total symptom score (TSS) in the 20mg group was significantly higher than in the placebo and 8 mg treatment group. The higher dose of 30 mg, on the other hand, did not significantly decrease symptom severity compared to the 20mg treatment, providing a rational for the usage of 20mg. Corresponding results were observed with the single PMS symptom scores. This study demonstrated that the VAC extract Ze 440 was effective in relieving symptoms of PMS, when applied in a dose of 20mg. Therefore, for patients suffering from PMS, 20mg Ze 440 should be the preferred daily dose. Copyright © 2012 Elsevier GmbH. All rights reserved.

  20. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk; Mohamad, Issa; Dayyat, Abdulmajeed

    2015-10-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dosemore » and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p < 0.001). As expected, photon-only plans demonstrated the highest target coverage and total lung V{sub 20} {sub Gy}. The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots associated with such plans. Combined photon-electron treatment is a feasible technique for supraclavicular nodal irradiation and results in adequate target coverage, acceptable dosimetric hotspot volume, and slightly reduced lung dose.« less

  1. Functional Voice Testing Detects Early Changes in Vocal Pitch in Women During Testosterone Administration

    PubMed Central

    Pencina, Karol M.; Coady, Jeffry A.; Beleva, Yusnie M.; Bhasin, Shalender; Basaria, Shehzad

    2015-01-01

    Objective: To determine dose-dependent effects of T administration on voice changes in women with low T levels. Methods: Seventy-one women who have undergone a hysterectomy with or without oophorectomy with total T < 31 ng/dL and/or free T < 3.5 pg/mL received a standardized transdermal estradiol regimen during the 12-week run-in period and were then randomized to receive weekly im injections of placebo or 3, 6.25, 12.5, or 25 mg T enanthate for 24 weeks. Total and free T levels were measured by liquid chromatography-tandem mass spectrometry and equilibrium dialysis, respectively. Voice handicap was measured by self-report using a validated voice handicap index questionnaire at baseline and 24 weeks after intervention. Functional voice testing was performed using the Kay Elemetrics-Computer Speech Lab to determine voice frequency, volume, and harmonics. Results: Forty-six women with evaluable voice data at baseline and after intervention were included in the analysis. The five groups were similar at baseline. Mean on-treatment nadir total T concentrations were 13, 83, 106, 122, and 250 ng/dL in the placebo, 3-, 6.25-, 12.5-, and 25-mg groups, respectively. Analyses of acoustic voice parameters revealed significant lowering of average pitch in the 12.5- and 25-mg dose groups compared to placebo (P < .05); these changes in pitch were significantly related to increases in T concentrations. No significant dose- or concentration-dependent changes in self-reported voice handicap index scores were observed. Conclusion: Testosterone administration in women with low T levels over 24 weeks was associated with dose- and concentration-dependent decreases in average pitch in the higher dose groups. These changes were seen despite the lack of self-reported changes in voice. PMID:25875779

  2. Functional Voice Testing Detects Early Changes in Vocal Pitch in Women During Testosterone Administration.

    PubMed

    Huang, Grace; Pencina, Karol M; Coady, Jeffry A; Beleva, Yusnie M; Bhasin, Shalender; Basaria, Shehzad

    2015-06-01

    To determine dose-dependent effects of T administration on voice changes in women with low T levels. Seventy-one women who have undergone a hysterectomy with or without oophorectomy with total T < 31 ng/dL and/or free T < 3.5 pg/mL received a standardized transdermal estradiol regimen during the 12-week run-in period and were then randomized to receive weekly im injections of placebo or 3, 6.25, 12.5, or 25 mg T enanthate for 24 weeks. Total and free T levels were measured by liquid chromatography-tandem mass spectrometry and equilibrium dialysis, respectively. Voice handicap was measured by self-report using a validated voice handicap index questionnaire at baseline and 24 weeks after intervention. Functional voice testing was performed using the Kay Elemetrics-Computer Speech Lab to determine voice frequency, volume, and harmonics. Forty-six women with evaluable voice data at baseline and after intervention were included in the analysis. The five groups were similar at baseline. Mean on-treatment nadir total T concentrations were 13, 83, 106, 122, and 250 ng/dL in the placebo, 3-, 6.25-, 12.5-, and 25-mg groups, respectively. Analyses of acoustic voice parameters revealed significant lowering of average pitch in the 12.5- and 25-mg dose groups compared to placebo (P < .05); these changes in pitch were significantly related to increases in T concentrations. No significant dose- or concentration-dependent changes in self-reported voice handicap index scores were observed. Testosterone administration in women with low T levels over 24 weeks was associated with dose- and concentration-dependent decreases in average pitch in the higher dose groups. These changes were seen despite the lack of self-reported changes in voice.

  3. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.

    PubMed

    Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li

    2016-04-01

    Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P <0.01). In patients with obesity, isotonic contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. Bile acid changes after high-dose ursodeoxycholic acid treatment in primary sclerosing cholangitis: relation to disease progression

    PubMed Central

    Sinakos, Emmanouil; Marschall, Hanns-Ulrich; Kowdley, Kris V.; Befeler, Alex; Keach, Jill; Lindor, Keith

    2010-01-01

    High-dose (28-30mg/kg/day) ursodeoxycholic acid (UDCA) treatment improves serum liver tests in patients with primary sclerosing cholangitis (PSC) but does not improve survival and is associated with increased rates of serious adverse events. The mechanism for the latter undesired effect remains unclear. High-dose UDCA could result in the production of hepatotoxic bile acids, such as lithocholic acid (LCA), due to limited small bowel absorption of UDCA and conversion of UDCA by bacteria in the colon. We determined the serum bile acid composition in 56 patients with PSC previously enrolled in a randomized, double-blind controlled trial of high dose UDCA versus placebo. Samples for analysis were obtained at baseline and at the end of treatment. The mean changes in UDCA (16.86 vs 0.05 μmol/L) and total bile acid (17.21 vs −0.55 μmol/L) levels were significantly higher in the UDCA group (n=29) compared to placebo (n=27) when pretreatment levels were compared (p<0.0001). LCA was also markedly increased (0.22 vs 0.01 μmol/L) in the UDCA group compared to placebo (p=0.001). No significant changes were detected for cholic acid (CA), deoxycholic acid (DCA) and chenodeoxycholic acid (CDCA). Patients (n=9) in the UDCA group who reached clinical endpoints of disease progression (development of cirrhosis, varices, liver transplantation or death) tend to have greater increase in their post-treatment total bile acid levels (34.99 vs 9.21 μmol/L) (p<0.08) compared to those who did not. Conclusion High-dose UDCA treatment in PSC patients results in marked UDCA enrichment and significant expansion of the total serum bile acid pool including lithocholic acid. PMID:20564380

  5. Glutamine Provides Effective Protection against Deltamethrin-Induced Acute Hepatotoxicity in Rats But Not Against Nephrotoxicity

    PubMed Central

    Gündüz, Ercan; Ülger, Burak Veli; İbiloğlu, İbrahim; Ekinci, Aysun; Dursun, Recep; Zengin, Yılmaz; İçer, Mustafa; Uslukaya, Ömer; Ekinci, Cenap; Güloğlu, Cahfer

    2015-01-01

    Background The aim of this study was to investigate the protective effects of L-glutamine (GLN) against liver and kidney injury caused by acute toxicity of deltamethrin (DLM). Material/Methods Thirty-two rats were indiscriminately separated into 4 groups with 8 rats each: control group (distilled water; 10 ml/kg, perorally [p.o.]), DLM group (35 mg/kg p.o. one dose.), GLN group (1.5 gr/kg, p.o. single dose.) and DLM (35 mg/kg p.o. one dose.) + GLN group (1.5 gr/kg, p.o. one dose after 4 hours.). Testing for total antioxidant status (TAS), total oxidant status (TOS), interleukin-1 beta (IL-1β), tumor necrosis factor-alpha (TNF-α), and interleukin-6 (IL-6) analyses were performed on tissue samples, and alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), urea, and creatinine were analyzed on serum samples. Liver and kidney samples were histopathologically analyzed. Results The TOS level in liver was significantly higher in the DLM group than in the control group, and the level in DLM+GLN group was considerably lower than in the DLM group. The TAS level in the DLM+GLN group was considerably higher than in the control and DLM groups. The TAS level in kidney tissues was considerably lower in the DLM group than in controls, but was similar to other groups. Histopathological analyses of liver tissues established a significant difference between DLM and DLM+GLN groups in terms of grade 2 hepatic injury. However, no significant difference was found between DLM and DLM+GLN groups in terms of kidney injury. Conclusions Glutamine leads to significant improvement in deltamethrin-induced acute hepatotoxicity in terms of histopathologic results, tissue oxidative stress parameters, and serum liver function marker enzymes. PMID:25890620

  6. The AAHKS Clinical Research Award: Intraosseous Regional Prophylaxis Provides Higher Tissue Concentrations in High BMI Patients in Total Knee Arthroplasty: A Randomized Trial.

    PubMed

    Chin, Seung Joon; Moore, Grant A; Zhang, Mei; Clarke, Henry D; Spangehl, Mark J; Young, Simon W

    2018-07-01

    Obesity is an established risk factor for periprosthetic joint infections after total knee arthroplasty (TKA). In obese patients, a larger dose of prophylactic vancomycin based on actual body weight is required to reach therapeutic concentrations. It is unclear how tissue concentrations are affected when intraosseous regional administration (IORA) is used in this population. This study compared tissue concentrations of low-dose vancomycin via IORA vs actual body weight-adjusted systemic intravenous (IV) dose in primary TKA. Twenty-two patients with a body mass index (BMI) >35 undergoing TKA were randomized into 2 groups. The IV group received 15 mg/kg (maximum of 2 g) of systemic IV vancomycin and the IORA group received 500 mg vancomycin into the tibia. Subcutaneous fat and bone samples were taken at regular intervals. Tissue antibiotic concentrations were measured using liquid chromatography coupled with tandem mass spectrometry. A blood sample was taken 1 to 2 hours after tourniquet deflation to measure systemic concentration. The mean BMI was 41.1 in the IORA group and 40.1 in the IV systemic group. The overall mean tissue concentration in subcutaneous fat was 39.3 μg/g in the IORA group and 4.4 μg/g in the IV systemic group (P < .01). Mean tissue concentrations in bones were 34.4 μg/g in the IORA group and 6.1 μg/g in the IV systemic group (P < .01). Low-dose IORA was effective in the high-BMI population group, providing tissue concentrations of vancomycin 5-9 times higher than systemic administration. IORA optimizes timing of vancomycin administration and provides high tissue antibiotic concentrations during TKA in this high-risk patient group. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. In vitro transdentinal effect of low-level laser therapy

    NASA Astrophysics Data System (ADS)

    Oliveira, C. F.; Basso, F. G.; dos Reis, R. I.; Parreiras-e-Silva, L. T.; Lins, E. C.; Kurachi, C.; Hebling, J.; Bagnato, V. S.; de Souza Costa, C. A.

    2013-05-01

    Low-level laser therapy (LLLT) has been used for the treatment of dentinal hypersensitivity. However, the specific LLL dose and the response mechanisms of these cells to transdentinal irradiation have not yet been demonstrated. Therefore, this study evaluated the transdentinal effects of different LLL doses on stressed odontoblast-like pulp cells MDPC-23 seeded onto the pulpal side of dentin discs obtained from human third molars. The discs were placed in devices simulating in vitro pulp chambers and the whole set was placed in 24-well plates containing plain culture medium (DMEM). After 24 h incubation, the culture medium was replaced by fresh DMEM supplemented with either 5% (simulating a nutritional stress condition) or 10% fetal bovine serum (FBS). The cells were irradiated with doses of 15 and 25 J cm-2 every 24 h, totaling three applications over three consecutive days. The cells in the control groups were removed from the incubator for the same times as used in their respective experimental groups for irradiation, though without activating the laser source (sham irradiation). After 72 h of the last active or sham irradiation, the cells were evaluated with respect to succinic dehydrogenase (SDH) enzyme production (MTT assay), total protein (TP) expression, alkaline phosphatase (ALP) synthesis, reverse transcriptase polymerase chain reaction (RT-PCR) for collagen type 1 (Col-I) and ALP, and morphology (SEM). For both tests, significantly higher values were obtained for the 25 J cm-2 dose. Regarding SDH production, supplementation of the culture medium with 5% FBS provided better results. For TP and ALP expression, the 25 J cm-2 presented higher values, especially for the 5% FBS concentration (Mann-Whitney p < 0.05). Under the tested conditions, near infrared laser irradiation at 25 J cm-2 caused transdentinal biostimulation of odontoblast-like MDPC-23 cells.

  8. Intravenous Vancomycin Associated With the Development of Nephrotoxicity in Patients With Class III Obesity.

    PubMed

    Choi, Yookyung Christy; Saw, Stephen; Soliman, Daniel; Bingham, Angela L; Pontiggia, Laura; Hunter, Krystal; Chuang, Linda; Siemianowski, Laura A; Ereshefsky, Benjamin; Hollands, James M

    2017-11-01

    A consensus statement recommends initial intravenous (IV) vancomycin dosing of 15-20 mg/kg every 8- 24 hours, with an optional 25- to 30-mg/kg loading dose. Although some studies have shown an association between weight and the development of vancomycin-associated nephrotoxicity, results have been inconsistent. To evaluate the correlation between incidence of nephrotoxicity associated with weight-based IV vancomycin dosing strategies in nonobese and obese patients. This retrospective cohort study evaluated hospitalized adult patients admitted who received IV vancomycin. Patients were stratified into nonobese (body mass index [BMI] <25 kg/m 2 ), obesity class I and II (BMI 30-39.9kg/m 2 ), and obesity class III (BMI≥40 kg/m 2 ) groups; patients who were overweight but not obese were excluded. Incidence of nephrotoxicity and serum vancomycin trough concentrations were evaluated. Of a total of 62 documented cases of nephrotoxicity (15.1%), 13 (8.7%), 23 (14.3%), and 26 (26.3%) cases were observed in nonobese, obesity class I and II, and obesity class III groups, respectively ( P=0.002). Longer durations of therapy ( P<0.0001), higher initial maintenance doses in both total milligrams/day ( P=0.0137) and milligrams/kilogram ( P=0.0307), and any trough level >20 mg/L ( P<0.0001) were identified as predictors of development of nephrotoxicity. Concomitant administration of piperacillin/tazobactam, diuretics, and IV contrast were associated with development of nephrotoxicity ( P<0.005, all). Patients with class III obesity were 3-times as likely to develop nephrotoxicity when compared with nonobese patients (odds ratio [OR]=2.99; CI=1.12-7.94) and obesity class I and II patients (OR=3.14; CI=1.27-7.75). Obesity and other factors are associated with a higher risk of vancomycin-associated nephrotoxicity.

  9. Effects of high-dose fish oil supplementation during early infancy on neurodevelopment and language: a randomised controlled trial.

    PubMed

    Meldrum, Suzanne J; D'Vaz, Nina; Simmer, Karen; Dunstan, Janet A; Hird, Kathryn; Prescott, Susan L

    2012-10-28

    n-3 Long-chain PUFA (LC-PUFA) intake during infancy is important for neurodevelopment; however, previous studies of n-3 LC-PUFA supplementation have been inconclusive possibly due to an insufficient dose and limited methods of assessment. The present study aimed to evaluate the effects of direct supplementation with high-dose fish oil (FO) on infant neurodevelopmental outcomes and language. In the present randomised, double-blind, placebo-controlled trial, 420 healthy term infants were assigned to receive a DHA-enriched FO supplement (containing at least 250 mg DHA/d and 60 mg EPA/d) or a placebo (olive oil) from birth to 6 months. Assessment occurred at 18 months via the Bayley Scales of Infant and Toddler Development (3rd edition; BSID-III) and the Child Behavior Checklist. Language assessment occurred at 12 and 18 months via the Macarthur-Bates Communicative Development Inventory. The FO group had significantly higher erythrocyte DHA (P = 0·03) and plasma phospholipid DHA (P = 0·01) levels at 6 months of age relative to placebo. In a small subset analysis (about 40% of the total population), children in the FO group had significantly higher percentile ranks of both later developing gestures at 12 and 18 months (P = 0·007; P = 0·002, respectively) and the total number of gestures (P = 0·023; P = 0·006, respectively). There was no significant difference between the groups in the standard or composite scores of the BSID-III. The results suggest that improved postnatal n-3 LC-PUFA intake in the first 6 months of life using high-dose infant FO supplementation was not beneficial to global infant neurodevelopment. However, some indication of benefits to early communicative development was observed.

  10. Effects of 3-nitrooxypropanol on methane emission, digestion, and energy and nitrogen balance of lactating dairy cows.

    PubMed

    Reynolds, C K; Humphries, D J; Kirton, P; Kindermann, M; Duval, S; Steinberg, W

    2014-01-01

    The objective was to measure effects of 3-nitrooxypropanol (3 NP) on methane production of lactating dairy cows and any associated changes in digestion and energy and N metabolism. Six Holstein-Friesian dairy cows in mid-lactation were fed twice daily a total mixed ration with maize silage as the primary forage source. Cows received 1 of 3 treatments using an experimental design based on two 3 × 3 Latin squares with 5-wk periods. Treatments were a control placebo or 500 or 2,500 mg/d of 3 NP delivered directly into the rumen, via the rumen fistula, in equal doses before each feeding. Measurements of methane production and energy and N balance were obtained during wk 5 of each period using respiration calorimeters and digestion trials. Measurements of rumen pH (48 h) and postprandial volatile fatty acid and ammonia concentrations were made at the end of wk 4. Daily methane production was reduced by 3 NP, but the effects were not dose dependent (reductions of 6.6 and 9.8% for 500 and 2,500 mg/d, respectively). Dosing 3 NP had a transitory inhibitory effect on methane production, which may have been due to the product leaving the rumen in liquid outflow or through absorption or metabolism. Changes in rumen concentrations of volatile fatty acids indicated that the pattern of rumen fermentation was affected by both doses of the product, with a decrease in acetate:propionate ratio observed, but that acetate production was inhibited by the higher dose. Dry matter, organic matter, acid detergent fiber, N, and energy digestibility were reduced at the higher dose of the product. The decrease in digestible energy supply was not completely countered by the decrease in methane excretion such that metabolizable energy supply, metabolizable energy concentration of the diet, and net energy balance (milk plus tissue energy) were reduced by the highest dose of 3 NP. Similarly, the decrease in N digestibility at the higher dose of the product was associated with a decrease in body N balance that was not observed for the lower dose. Milk yield and milk fat concentration and fatty acid composition were not affected but milk protein concentration was greater for the higher dose of 3 NP. Twice-daily rumen dosing of 3 NP reduced methane production by lactating dairy cows, but the dose of 2,500 mg/d reduced rumen acetate concentration, diet digestibility, and energy supply. Further research is warranted to determine the optimal dose and delivery method of the product. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Effects of Altering Levothyroxine (L-T4) Doses on Quality of Life, Mood, and Cognition in L-T4 Treated Subjects.

    PubMed

    Samuels, Mary H; Kolobova, Irina; Niederhausen, Meike; Janowsky, Jeri S; Schuff, Kathryn G

    2018-05-01

    The brain is a critical target organ for thyroid hormone, but it is unclear whether variations in thyroid function within and near the reference range affect quality of life, mood, or cognition. A total of 138 subjects with levothyroxine (L-T4)-treated hypothyroidism and normal thyrotropin (TSH) levels underwent measures of quality of life (36-Item Short Form Health Survey, Underactive Thyroid-Dependent Quality of Life Questionnaire), mood (Profile of Mood States, Affective Lability Scale), and cognition (executive function, memory). They were then randomly assigned to receive an unchanged, higher, or lower L-T4 dose in double-blind fashion, targeting one of three TSH ranges (0.34 to 2.50, 2.51 to 5.60, or 5.61 to 12.0 mU/L). Doses were adjusted every 6 weeks based on TSH levels. Baseline measures were reassessed at 6 months. At the end of the study, by intention to treat, mean L-T4 doses were 1.50 ± 0.07, 1.32 ± 0.07, and 0.78 ± 0.08 μg/kg (P < 0.001), and mean TSH levels were 1.85 ± 0.25, 3.93 ± 0.38, and 9.49 ± 0.80 mU/L (P < 0.001), respectively, in the three arms. There were minor differences in a few outcomes between the three arms, which were no longer significant after correction for multiple comparisons. Subjects could not ascertain how their L-T4 doses had been adjusted (P = 0.55) but preferred L-T4 doses they perceived to be higher (P < 0.001). Altering L-T4 doses in hypothyroid subjects to vary TSH levels in and near the reference range does not affect quality of life, mood, or cognition. L-T4-treated subjects prefer perceived higher L-T4 doses despite a lack of objective benefit. Adjusting L-T4 doses in hypothyroid patients based on symptoms in these areas may not result in significant clinical improvement.

  12. Opioid Patient Controlled Analgesia (PCA) use during the Initial Experience with the IMPROVE PCA Trial: A Phase III Analgesic Trial for Hospitalized Sickle Cell Patients with Painful Episodes

    PubMed Central

    Dampier, Carlton D.; Smith, Wally R.; Kim, Hae-Young; Wager, Carrie Greene; Bell, Margaret C.; Minniti, Caterina P.; Keefer, Jeffrey; Hsu, Lewis; Krishnamurti, Lakshmanan; Mack, A. Kyle; McClish, Donna; McKinlay, Sonja M.; Miller, Scott T.; Osunkwo, Ifeyinwa; Seaman, Phillip; Telen, Marilyn J.; Weiner, Debra L.

    2015-01-01

    Opioid analgesics administered by patient-controlled analgesia (PCA) are frequently used for pain relief in children and adults with sickle cell disease (SCD) hospitalized for persistent vaso-occlusive pain, but optimum opioid dosing is not known. To better define PCA dosing recommendations, a multi-center phase III clinical trial was conducted comparing two alternative opioid PCA dosing strategies (HDLI-higher demand dose with low constant infusion or LDHI- lower demand dose and higher constant infusion) in 38 subjects who completed randomization prior to trial closure. Total opioid utilization (morphine equivalents, mg/kg) in 22 adults was 11.6 ± 2.6 and 4.7 ± 0.9 in the HDLI and in the LDHI arms, respectively, and in 12 children it was 3.7 ± 1.0 and 5.8 ± 2.2, respectively. Opioid-related symptoms were mild and similar in both PCA arms (mean daily opioid symptom intensity score: HDLI 0.9 ± 0.1, LDHI 0.9 ± 0.2). The slow enrollment and early study termination limited conclusions regarding superiority of either treatment regimen. This study adds to our understanding of opioid PCA usage in SCD. Future clinical trial protocol designs for opioid PCA may need to consider potential differences between adults and children in PCA usage. PMID:21953763

  13. Effect of Gamma Radiations on the Quality and Shelf Life of Strawberry Fruit of the Uttrakhand Region

    NASA Astrophysics Data System (ADS)

    Sharma, Prianka; Rastogi, Meetu

    2016-08-01

    Present study was conducted to investigate the effect of gamma radiations on the quality and shelf life of strawberries. The aim of this study was to evaluate gamma radiation doses in range of 0.3- 1.5 kGy. The irradiated strawberries were stored in ambient (temperature 25 +- 2oC, RH 70 %) and refrigerated (3 +-1oC, RH 80%) conditions. In samples treated with dose 1.2-1.5 kGy no decay was recorded up to 9 days of ambient conditions. Under refrigerated conditions, strawberry samples of unirradiated and irradiated in the range of 0.3-0.9 kGy started decaying after 14 days of storage. No decay was observed in the samples treated with 1.2-1.5 kGy up to 28 days of refrigerated storage. Dose of 1.2 kGy was significantly effective in reducing the weight loss and in maintaining the higher overall acceptability under both the storage conditions compared to the other treatments. This dose also proved effective in retention of significantly higher levels of total sugars compared to the other treatments. Thus, it was established that irradiating strawberries with dose of 1.2 kGy can prove beneficial in facilitating the marketing of the fruit to distant places other than the local markets, thereby benefiting the growers.

  14. Opioid patient controlled analgesia use during the initial experience with the IMPROVE PCA trial: a phase III analgesic trial for hospitalized sickle cell patients with painful episodes.

    PubMed

    Dampier, Carlton D; Smith, Wally R; Kim, Hae-Young; Wager, Carrie Greene; Bell, Margaret C; Minniti, Caterina P; Keefer, Jeffrey; Hsu, Lewis; Krishnamurti, Lakshmanan; Mack, A Kyle; McClish, Donna; McKinlay, Sonja M; Miller, Scott T; Osunkwo, Ifeyinwa; Seaman, Phillip; Telen, Marilyn J; Weiner, Debra L

    2011-12-01

    Opioid analgesics administered by patient-controlled analgesia (PCA)are frequently used for pain relief in children and adults with sickle cell disease (SCD) hospitalized for persistent vaso-occlusive pain, but optimum opioid dosing is not known. To better define PCA dosing recommendations,a multi-center phase III clinical trial was conducted comparing two alternative opioid PCA dosing strategies (HDLI—higher demand dose with low constant infusion or LDHI—lower demand dose and higher constant infusion) in 38 subjects who completed randomization prior to trial closure. Total opioid utilization (morphine equivalents,mg/kg) in 22 adults was 11.6 ± 2.6 and 4.7 ± 0.9 in the HDLI andin the LDHI arms, respectively, and in 12 children it was 3.7 ± 1.0 and 5.8 ± 2.2, respectively. Opioid-related symptoms were mild and similar in both PCA arms (mean daily opioid symptom intensity score: HDLI0.9 ± 0.1, LDHI 0.9 ± 0.2). The slow enrollment and early study termination limited conclusions regarding superiority of either treatment regimen. This study adds to our understanding of opioid PCA usage in SCD. Future clinical trial protocol designs for opioid PCA may need to consider potential differences between adults and children in PCA usage.

  15. Bismuth-Silicon and Bismuth-Polyurethane Composite Shields for Breast Protection in Chest Computed Tomography Examinations

    PubMed Central

    Mehnati, Parinaz; Arash, Mehran; Akhlaghi, Parisa

    2018-01-01

    The article aims at constructing protective composite shields for breasts in chest computed tomography and investigating the effects of applying these new bismuth composites on dose and image quality. Polyurethane and silicon with 5% of bismuth were fabricated as a protective shield. At first, their efficiency in attenuating the X-ray beam was investigated by calculating the total attenuation coefficients at diagnostic energy range. Then, a physical chest phantom was scanned without and with these shields at tube voltage of 120 kVp, and image parameters together with dose values were studied. The results showed that these two shields have great effects on attenuating the X-ray beam, especially for lower energies (<40 kV), and in average, the attenuation coefficients of bismuth-polyurethane composite are higher in this energy range. The maximum relative differences between the average Hounsfield units (HUs) and noises of images without and with shield for both composites in 13 regions of interest were 4.5% and 15.7%, respectively. Moreover, primary investigation confirmed the ability of both shields (especially polyurethane-bismuth composite) in dose reduction. Comparing these two composites regarding the amount of dose reduction, the changes in HU and noise, and attenuation coefficients in diagnostic energy range, it seems that polyurethane composite is more useful for dose reduction, especially for higher tube voltages. PMID:29628636

  16. [Estimation of dietary intake of radioactive materials by total diet methods].

    PubMed

    Uekusa, Yoshinori; Nabeshi, Hiromi; Tsutsumi, Tomoaki; Hachisuka, Akiko; Matsuda, Rieko; Teshima, Reiko

    2014-01-01

    Radioactive contamination in foods is a matter of great concern after the Tokyo Electric Power Company's Fukushima Daiichi nuclear power plant disaster caused by the Great East Japan Earthquake. In order to estimate human intake and annual committed effective dose of radioactive materials, market basket and duplicate diet samples from various areas in Japan were analyzed for cesium-134 ((134)Cs), -137 ((137)Cs), and natural radionuclide potassium-40 ((40)K) by γ-ray spectroscopy. Dietary intake of radioactive cesium around Fukushima area was somewhat higher than in other areas. However, maximum committed effective doses obtained by the market basket and duplicate diet samples were 0.0094 and 0.027 mSv/year, respectively, which are much lower than the maximum permissible dose (1 mSv/year) in foods in Japan.

  17. Radiation protocols determine acute graft-versus-host disease incidence after allogeneic bone marrow transplantation in murine models.

    PubMed

    Schwarte, Sebastian; Bremer, Michael; Fruehauf, Joerg; Sorge, Yanina; Skubich, Susanne; Hoffmann, Matthias W

    2007-09-01

    Effects of radiation sources used for total body irradiation (TBI) on Graft-versus-Host Disease (GvHD) induction were examined. In a T cell receptor (TCR) transgenic mouse model, single fraction TBI was performed with different radiation devices ((60)Cobalt; (137)Cesium; 6 MV linear accelerator), dose rates (0.85; 1.5; 2.9; 5 Gy/min) and total doses before allogeneic bone marrow transplantation (BMT). Recipients were observed for 120 days. Different tissues were examined histologically. Acute GvHD was induced by a dose rate of 0.85 Gy/min ((60)Cobalt) and a total dose of 9 Gy and injection of 5 x 10(5) lymph node cells plus 5 x 10(6) bone marrow cells. Similar results were obtained using 6 MV linear accelerator- (linac-) photons with a dose rate of 1.5 Gy/min and 0.85 Gy/min, a total dose of 9.5 Gy and injection of same cell numbers. TBI with (137)Cesium (dose rate: 2.5 Gy/min) did not lead reproducibly to lethal acute GvHD. Experimental TBI in murine models may induce different immunological responses, depending on total energy, total single dose and dose rate. GvHD might also be induced by TBI with low dose rates.

  18. A comparison between simplified and intensive dose-titration algorithms using AIR inhaled insulin for insulin-naive patients with type 2 diabetes in a randomized noninferiority trial.

    PubMed

    Mathieu, C; Cuddihy, R; Arakaki, R F; Belin, R M; Planquois, J-M; Lyons, J N; Heilmann, C R

    2009-09-01

    Insulin initiation and optimization is a challenge for patients with type 2 diabetes. Our objective was to determine whether safety and efficacy of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) using a simplified regimen was noninferior to an intensive regimen. This was an open-label, randomized study in insulin-naive adults not optimally controlled by oral antihyperglycemic medications. Simplified titration included a 6 U per meal AIR insulin starting dose. Individual doses were adjusted at mealtime in 2-U increments from the previous day's four-point self-monitored blood glucose (SMBG) (total < or =6 U). Starting Air insulin doses for intensive titration were based on fasting blood glucose, gender, height, and weight. Patients conducted four-point SMBG daily for the study duration. Insulin doses were titrated based on the previous 3 days' mean SMBG (total < or =8 U). End point hemoglobin A1C (A1C) was 7.07 +/- 0.09% and 6.87 +/- 0.09% for simplified (n = 178) and intensive (n = 180) algorithms, respectively. Noninferiority between algorithms was not established. The fasting blood glucose (least squares mean +/- standard error) values for the simplified (137.27 +/- 3.42 mg/dL) and intensive (133.13 +/- 3.42 mg/dL) algorithms were comparable. Safety profiles were comparable. The hypoglycemic rate at 4, 8, 12, and 24 weeks was higher in patients receiving intensive titration (all P < .0001). The nocturnal hypoglycemic rate for patients receiving intensive titration was higher than for those receiving simplified titration at 8 (P < 0.015) and 12 weeks (P < 0.001). Noninferiority between the algorithms, as measured by A1C, was not demonstrated. This finding re-emphasizes the difficulty of identifying optimal, simplified insulin regimens for patients.

  19. Retrospective evaluation of xylitol ingestion in dogs: 192 cases (2007-2012).

    PubMed

    DuHadway, Meghan R; Sharp, Claire R; Meyers, Katherine E; Koenigshof, Amy M

    2015-01-01

    To summarize the signalment, clinical signs, prevalence of decreased blood glucose concentration (BG), prevalence of increased liver values, treatment, and outcome in dogs known to have ingested xylitol. Retrospective study from December 2007 to February 2012 SETTING: Three university teaching hospitals. One hundred ninety-two client-owned dogs with known or suspected xylitol ingestion. None. The median ingested xylitol dose was 0.32 g/kg (range 0.03-3.64 g/kg). Clinical signs were present in 39 (20%) dogs on presentation to the veterinary teaching hospitals. The most common clinical sign was vomiting (n = 25), followed by lethargy (12). The median duration of clinical signs prior to presentation was 93 minutes (range 0-5,040 minutes). Dogs that developed clinical signs ingested a significantly higher dose of xylitol than those that were asymptomatic. Thirty dogs became hypoglycemic (BG ≤ 3.3 mmol/L [60 mg/dL]) at some time point during their hospitalization. When evaluating all dogs, there was a significant difference between the initial and lowest BGs. Thirty dogs had increased alanine aminotransferase activity or total serum bilirubin concentration. Dogs with increases in alanine aminotransferase activity or total serum bilirubin concentration had a significantly lower nadir BG. All dogs survived to discharge and 158 were known to be alive at 28 days. The rest were lost to follow up. The prognosis for dogs evaluated by a veterinarian that ingest lower doses of xylitol and do not develop liver failure is excellent. Dogs ingesting xylitol should be hospitalized and monitored for variations in BG, because BG drops in most dogs following presentation. Additional studies are needed in dogs ingesting higher doses of xylitol before correlations between dose and the development of clinical signs or liver failure can be established. Treatment and prognosis for these dogs warrants further investigation. © Veterinary Emergency and Critical Care Society 2015.

  20. Does measuring BHR add to guideline derived clinical measures in determining treatment for patients with persistent asthma?

    PubMed

    Koenig, Steven M; Murray, John J; Wolfe, James; Andersen, Leslie; Yancey, Steve; Prillaman, Barbara; Stauffer, John; Dorinsky, Paul

    2008-05-01

    Little is known about the use of biomarkers in guiding treatment decisions in routine asthma management. The objective of this study was to determine whether adding a LABA to an ICS would control bronchial hyperresponsiveness (BHR) at an overall lower dose of ICS when titration of medication was based upon the assessment of routine clinical measures with or without the measurement of BHR. After a 2-week run-in period, subjects (> or = 12 years) were randomized to one of three treatment groups. Two groups followed a BHR treatment strategy (based on clinical parameters [lung function, asthma symptoms, and bronchodilator use] and BHR) and were treated with either fluticasone propionate/salmeterol (FSC(BHR) group) or fluticasone propionate (FP(BHR) group) (n=156 each). The third group followed a clinical treatment algorithm (based on clinical parameters alone) and were treated with fluticasone propionate (FP(REF) group; n=154). All treatments were administered via Diskus. Treatment doses were adjusted as needed every 8 weeks for 40 weeks according to the subject's derived severity class, which was based on clinical measures of asthma control with or without BHR. The mean total daily inhaled corticosteroids (ICS) dose during the double-blind treatment period was lower, although not statistically significant, in the FSC(BHR) group compared with the FP(BHR) group (a difference of -42.9 mcg; p=0.07). Compared with the FP(REF) group, the mean total daily ICS dose was higher in the FSC(BHR) group (a difference of 85.2 mcg) and was significantly higher in the FP(BHR) group (a difference of 131.2 mcg, p=0.037). This study demonstrated that for most subjects, control of BHR was maintained when treatment was directed toward control of clinical parameters. In addition, there was a trend towards control of BHR and clinical measures at a lower dose of ICS when used concurrently with salmeterol.

  1. Optimization of contrast-enhanced spectral mammography depending on clinical indication

    PubMed Central

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-01-01

    Abstract. The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality. PMID:26158058

  2. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    PubMed

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  3. Seeking Beta: Experimental Considerations and Theoretical Implications Regarding the Detection of Curvature in Dose-Response Relationships for Chromosome Aberrations.

    PubMed

    Shuryak, Igor; Loucas, Bradford D; Cornforth, Michael N

    2017-01-01

    The concept of curvature in dose-response relationships figures prominently in radiation biology, encompassing a wide range of interests including radiation protection, radiotherapy and fundamental models of radiation action. In this context, the ability to detect even small amounts of curvature becomes important. Standard (ST) statistical approaches used for this purpose typically involve least-squares regression, followed by a test on sums of squares. Because we have found that these methods are not particularly robust, we investigated an alternative information theoretic (IT) approach, which involves Poisson regression followed by information-theoretic model selection. Our first objective was to compare the performances of the ST and IT methods by using them to analyze mFISH data on gamma-ray-induced simple interchanges in human lymphocytes, and on Monte Carlo simulated data. Real and simulated data sets that contained small-to-moderate curvature were deliberately selected for this exercise. The IT method tended to detect curvature with higher confidence than the ST method. The finding of curvature in the dose response for true simple interchanges is discussed in the context of fundamental models of radiation action. Our second objective was to optimize the design of experiments aimed specifically at detecting curvature. We used Monte Carlo simulation to investigate the following parameters. Constrained by available resources (i.e., the total number of cells to be scored) these include: the optimal number of dose points to use; the best way to apportion the total number of cells among these dose points; and the spacing of dose intervals. Counterintuitively, our simulation results suggest that 4-5 radiation doses were typically optimal, whereas adding more dose points may actually prove detrimental. Superior results were also obtained by implementing unequal dose spacing and unequal distributions in the number of cells scored at each dose.

  4. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    PubMed Central

    Zeng, Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei

    2013-01-01

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled. PMID:23635256

  5. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.

    PubMed

    Zeng, Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A; Trofimov, Alexei

    2013-05-01

    Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.

  6. Natural gamma-radiation in the Aeolian volcanic arc.

    PubMed

    Chiozzi, P; Pasquale, V; Verdoya, M; Minato, S

    2001-11-01

    Pulse-height distributions of gamma-rays, obtained with a field NaI(Tl) scintillation spectrometer in numerous sites of the Lipari and Vulcano islands (Aeolian volcanic arc, Italy), were measured to determine the U, Th and K concentrations of the bedrock and the relative values of the air absorbed dose rate. U is spatially related to both Th and K and the Th/U ratio is on average 3.1-3.5. The magmatic evolution is reflected by the concentration of the three radioelements, as they are more abundant within the more felsic units of the volcanic series. The higher values of U (15.7-20.0 ppm) coincide with higher Th (48.3-65.9 ppm) and K (4.9-6.1%) concentrations associated with rhyolitic rocks of the third cycle (< 50 ky). The air absorbed dose rate varies from 20 to 470 nGy h(-1). The highest values (> 350 nGy h(-1)) are observed on outcrops of rhyolitic obsidian lava flows. The cosmic-ray contribution is also evaluated to estimate the total background radiation dose rate.

  7. Suppression of streptozotocin-induced type-1 diabetes in mice by radon inhalation.

    PubMed

    Nishiyama, Y; Kataoka, T; Teraoka, J; Sakoda, A; Tanaka, H; Ishimori, Y; Mitsunobu, F; Taguchi, T; Yamaoka, K

    2013-01-01

    We examined the protective effect of radon inhalation on streptozotocin (STZ)-induced type-1 diabetes in mice. Mice inhaled radon at concentrations of 1000, 2500, and 5500 Bq/m3 for 24 hours before STZ administration. STZ administration induced characteristics of type-1 diabetes such as hyperglycemia and hypoinsulinemia; however, radon inhalation at doses of 1000 and 5500 Bq/m3 significantly suppressed the elevation of blood glucose in diabetic mice. Serum insulin was significantly higher in mice pre-treated with radon at a dose of 1000 Bq/m3 than in mice treated with a sham. In addition, superoxide dismutase activities and total glutathione contents were significantly higher and lipid peroxide was significantly lower in mice pre-treated with radon at doses of 1000 and 5500 Bq/m3 than in mice treated with a sham. These results were consistent with the result that radon inhalation at 1000 and 5500 Bq/m3 suppressed hyperglycemia. These findings suggested that radon inhalation suppressed STZ-induced type-1 diabetes through the enhancement of antioxidative functions in the pancreas.

  8. Preparation of metallic nanoparticles by irradiation in starch aqueous solution

    NASA Astrophysics Data System (ADS)

    NemÅ£anu, Monica R.; Braşoveanu, Mirela; Iacob, Nicuşor

    2014-11-01

    Colloidal silver nanoparticles (AgNPs) were synthesized in a single step by electron beam irradiation reduction of silver ions in aqueous solution containing starch. The nanoparticles were characterized by spectrophotocolorimetry and compared with those obtained by chemical (thermal) reduction method. The results showed that the smaller sizes of AgNPs were prepared with higher yields as the irradiation dose increased. The broadening of particle size distribution occurred by increasing of irradiation dose and dose rate. Chromatic parameters such as b* (yellow-blue coordinate), C* (chroma) and ΔEab (total color difference) could characterize the nanoparticles with respect of their concentration. Hue angle ho was correlated to the particle size distribution. Experimental data of the irradiated samples were also subjected to factor analysis using principal component extraction and varimax rotation in order to reveal the relation between dependent variables and independent variables and to reduce their number. The radiation-based method provided silver nanoparticles with higher concentration and narrower size distribution than those produced by chemical reduction method. Therefore, the electron beam irradiation is effective for preparation of silver nanoparticles using starch aqueous solution as dispersion medium.

  9. Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

    PubMed

    Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C

    2016-10-10

    The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

  10. Cytogenetic and viability effects of petroleum aromatic and PCB hydrocarbons, temperature and salinity, on early development of the American oyster, Crassostrea virginica Gmelin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stiles-Jewell, S.

    1994-01-01

    Fertilized eggs were exposed to 0.1, 10 and 100 mg/l of benzene, naphthalene and Aroclor 1254 individually and in combination in seawater at temperatures and salinities of 20 and 25. Toxicity was measured as frequencies of: (1) meiotic and mitotic abnormalities in 3-hour embryos; (2) total development to the 48-hour straight-hinge larval stage; (3) mortality and abnormality at the 48-hour larval stage; (4) mean size of larvae at 48 hours; and (5) cytogenetic and cytological abnormalities in 48-hour larvae. Dose-dependent responses were observed. Overall, naphthalene and aroclor at 100 mg/l had few embryos that survived to the stage where theymore » could be examined and scored for cytogenetic and cytological abnormality even by 3-hours post-fertilization. Abnormality of the few embryos available for examination was somewhat higher for aroclor but was significantly higher for naphthalene than for control embryos and those exposed to 0.1 mg/l. At the highest concentration of 100 mg/l, mortality was 100% by the larval stage for naphthalene and aroclor. Though total development and survival of embryos to the larval stage at the 10 mg/l dose were high, many of the larvae were dead or abnormal in the aroclor-exposed cultures. This mean incidence was significantly higher than for all other groups. Larvae developing in these cultures with 10 mg/l were also significantly smaller and cytological condition of the larvae was significantly worse. Higher temperature appeared to increase the frequency of deleterious effects, particularly for naphthalene and aroclor. Results with salinity were more variable. Overall, results showed that petroleum aromatic hydrocarbons and PCBs can have toxic effects on the development and survival of early life stages of oysters, as well as sublethal effects on growth and cytological condition, depending on dose and interactions with other compound and with environmental variables.« less

  11. Phosphate Fertilizer and Growing Environment Change the Phytochemicals, Oil Quality, and Nutritional Composition of Roundup Ready Genetically Modified and Conventional Soybean.

    PubMed

    Scilewski da Costa Zanatta, Tatiane; Manica-Berto, Roberta; Ferreira, Cristiano Dietrich; Cardozo, Michele Maciel Crizel; Rombaldi, Cesar Valmor; Zambiazi, Rui Carlos; Dias, Álvaro Renato Guerra

    2017-04-05

    Phosphorus (P) intake, genotype, and growth environment in soybean cultivation can affect the composition of the soybean. This experiment was conducted in two locations (microregions I and II) using a randomized complete block design, including conventional soybean (BRS Sambaíba) and genetically modified (GM) [Msoy 9144 Roundup Ready (RR)] cultivars and varying doses of phosphorus fertilizer (0, 60, 120, and 240 kg/ha P 2 O 5 ). Soybeans were evaluated for chemical composition, total phenols, phytic acid content, individual isoflavone content, antioxidant activity, oil quality, fatty acid profile, total carotenoid content, and individual tocopherol contents. Multivariate analysis facilitated reduction in the number of variables with respect to soybean genotype (conventional BRS Sambaíba and GM Msoy 9144 RR), dose of P 2 O 5 fertilizer, and place of cultivation (microregion I and II). BRS Sambaíba had higher concentrations of β-glucosides, malonylglucosides, glycitein, and genistein than Msoy 9144 RR, which showed a higher concentration of daidzein. The highest concentrations of isoflavones and fatty acids were observed in soybeans treated with 120 and 240 kg/ha P 2 O 5 , regardless of the location and cultivar.

  12. Treatment of Endometriosis-Associated Pain with Elagolix, an Oral GnRH Antagonist.

    PubMed

    Taylor, Hugh S; Giudice, Linda C; Lessey, Bruce A; Abrao, Mauricio S; Kotarski, Jan; Archer, David F; Diamond, Michael P; Surrey, Eric; Johnson, Neil P; Watts, Nelson B; Gallagher, J Chris; Simon, James A; Carr, Bruce R; Dmowski, W Paul; Leyland, Nicholas; Rowan, Jean P; Duan, W Rachel; Ng, Juki; Schwefel, Brittany; Thomas, James W; Jain, Rita I; Chwalisz, Kristof

    2017-07-06

    Endometriosis is a chronic, estrogen-dependent condition that causes dysmenorrhea and pelvic pain. Elagolix, an oral, nonpeptide, gonadotropin-releasing hormone (GnRH) antagonist, produced partial to nearly full estrogen suppression in previous studies. We performed two similar, double-blind, randomized, 6-month phase 3 trials (Elaris Endometriosis I and II [EM-I and EM-II]) to evaluate the effects of two doses of elagolix - 150 mg once daily (lower-dose group) and 200 mg twice daily (higher-dose group) - as compared with placebo in women with surgically diagnosed endometriosis and moderate or severe endometriosis-associated pain. The two primary efficacy end points were the proportion of women who had a clinical response with respect to dysmenorrhea and the proportion who had a clinical response with respect to nonmenstrual pelvic pain at 3 months. Each of these end points was measured as a clinically meaningful reduction in the pain score and a decreased or stable use of rescue analgesic agents, as recorded in a daily electronic diary. A total of 872 women underwent randomization in Elaris EM-I and 817 in Elaris EM-II; of these women, 653 (74.9%) and 632 (77.4%), respectively, completed the intervention. At 3 months, a significantly greater proportion of women who received each elagolix dose met the clinical response criteria for the two primary end points than did those who received placebo. In Elaris EM-I, the percentage of women who had a clinical response with respect to dysmenorrhea was 46.4% in the lower-dose elagolix group and 75.8% in the higher-dose elagolix group, as compared with 19.6% in the placebo group; in Elaris EM-II, the corresponding percentages were 43.4% and 72.4%, as compared with 22.7% (P<0.001 for all comparisons). In Elaris EM-I, the percentage of women who had a clinical response with respect to nonmenstrual pelvic pain was 50.4% in the lower-dose elagolix group and 54.5% in the higher-dose elagolix group, as compared with 36.5% in the placebo group (P<0.001 for all comparisons); in Elaris EM-II, the corresponding percentages were 49.8% and 57.8%, as compared with 36.5% (P=0.003 and P<0.001, respectively). The responses with respect to dysmenorrhea and nonmenstrual pelvic pain were sustained at 6 months. Women who received elagolix had higher rates of hot flushes (mostly mild or moderate), higher levels of serum lipids, and greater decreases from baseline in bone mineral density than did those who received placebo; there were no adverse endometrial findings. Both higher and lower doses of elagolix were effective in improving dysmenorrhea and nonmenstrual pelvic pain during a 6-month period in women with endometriosis-associated pain. The two doses of elagolix were associated with hypoestrogenic adverse effects. (Funded by AbbVie; Elaris EM-I and EM-II ClinicalTrials.gov numbers, NCT01620528 and NCT01931670 .).

  13. Total Dose Effects on Bipolar Integrated Circuits at Low Temperature

    NASA Technical Reports Server (NTRS)

    Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.

    2012-01-01

    Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.

  14. Ketamine versus alfentanil combined with propofol for sedation in colonoscopy procedures: a randomized prospective study.

    PubMed

    Türk, Hacer Şebnem; Aydoğmuş, Meltem; Ünsal, Oya; Işıl, Canan Tülay; Citgez, Bülent; Oba, Sibel; Açık, Mehmet Eren

    2014-12-01

    Different drug combinations are used for sedation in colonoscopy procedures. A ketamine-propofol (ketofol) mixture provides effective sedation and has minimal adverse effects. Alfentanil also provides anesthesia for short surgical procedures by incremental injection as an adjunct. However, no study has investigated the use of ketofol compared with an opioid-propofol combination in colonoscopic procedures. A total of 70 patients, ASA physical status I-II, scheduled to undergo elective colonoscopy, were enrolled in this prospective randomized study and allocated to two groups. After premedication, sedation induction was performed with 0.5 mg/kg ketamine +1 mg/kg propofol in Group KP, and 10 mg/kg alfentanil +1 mg/kg propofol in Group AP. Propofol was added when required. Demographic data, colonoscopy duration, recovery time, discharge time, mean arterial pressure (MAP), heart rate (HR), peripheral oxygen saturation, Ramsey Sedation Scale values, colonoscopy patients' satisfaction scores, and complications were recorded. The need for additional propofol doses was significantly higher in Group AP than in Group KP. MAP at minute 1 and 5, Ramsey Sedation Scale at minute 5, and discharge time were significantly higher in Group KP than in Group AP. Additional propofol doses and total propofol dose were significantly lower in Group KP than in Group AP. Ketofol provided better hemodynamic stability and quality of sedation compared with alfentanil-propofol combination in elective colonoscopy, and required fewer additional propofol; however, it prolonged discharge time. Both combinations can safely be used in colonoscopy sedation.

  15. High-dose Versus Low-dose Tranexamic Acid to Reduce Transfusion Requirements in Pediatric Scoliosis Surgery.

    PubMed

    Johnson, Daniel J; Johnson, Christine C; Goobie, Susan M; Nami, Nina; Wetzler, Joshua A; Sponseller, Paul D; Frank, Steven M

    2017-12-01

    Our objective was to quantify blood loss and transfusion requirements for high-dose and low-dose tranexamic acid (TXA) dosing regimens in pediatric patients undergoing spinal fusion for correction of idiopathic scoliosis. Previous investigators have established the efficacy of TXA in pediatric scoliosis surgery; however, the dosing regimens vary widely and the optimal dose has not been established. We retrospectively analyzed electronic medical records for 116 patients who underwent spinal fusion surgery for idiopathic scoliosis by a single surgeon and were treated with TXA. In total, 72 patients received a 10 mg/kg loading dose with a 1 mg/kg/h maintenance dose (low-dose) and 44 patients received 50 mg/kg loading dose with a 5 mg/kg/h maintenance dose (high-dose). Estimated blood loss and transfusion requirements were compared between dosing groups. Patient characteristics were nearly identical between the 2 groups. Compared with the low-dose TXA group, the high-dose TXA group had decreased estimated blood loss (695 vs. 968 mL, P=0.01), and a decrease in both intraoperative (0.3 vs. 0.9 units, P=0.01) and whole hospitalization (0.4 vs. 1.0 units, P=0.04) red blood cell transfusion requirements. The higher-dose TXA was associated with decreased intraoperative (P=0.01), and whole hospital transfusion (P=0.01) requirements, even after risk-adjustment for potential confounding variables. High-dose TXA is more effective than low-dose TXA in reducing blood loss and transfusion requirements in pediatric idiopathic scoliosis patients undergoing surgery. Level-III, retrospective cohort study.

  16. ²²⁶Ra, ²³²Th and ⁴⁰K radionuclides enhancement rate and dose assessment for residues of lignite-fired thermal power plants in Turkey.

    PubMed

    Parmaksiz, A; Arikan, P; Vural, M; Yeltepe, E; Tükenmez, I

    2011-11-01

    A total of 77 coal, slag and fly ash samples collected from six thermal power plants were measured by gamma-ray spectrometry. The average (226)Ra activity concentrations in coal, slag and fly ash were measured as 199.8±16.7, 380.3±21.8 and 431.5±29.0 Bq kg(-1), respectively. The average (232)Th activity concentrations in coal, slag and fly ash were measured as 32.0±2.4, 74.0±9.0 and 87.3±9.8 Bq kg(-1), respectively. The average (40)K activity concentrations in coal, slag and fly ash were found to be 152.8±12.1, 401.3±25.0 and 439.0±30.2 Bq kg(-1), respectively. The radium equivalent activities of samples varied from 147.6±8.5 to 1077.4±53.3 Bq kg(-1). The gamma and alpha index of one thermal power plant's fly ash were calculated to be 3.5 and 5 times higher than that of the reference values. The gamma absorbed dose rates were found to be higher than that of the average Earth's crust. The annual effective dose of residues measured in four thermal power plants were calculated higher than that of the permitted dose rate for public, i.e. 1 mSv y(-1).

  17. Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom

    PubMed Central

    Kim, K. P.; Berrington de González, A.; Pearce, M. S.; Salotti, J. A.; Parker, L.; McHugh, K.; Craft, A. W.; Lee, C.

    2012-01-01

    Despite great potential benefits, there are concerns about the possible harm from medical imaging including the risk of radiation-related cancer. There are particular concerns about computed tomography (CT) scans in children because both radiation dose and sensitivity to radiation for children are typically higher than for adults undergoing equivalent procedures. As direct empirical data on the cancer risks from CT scans are lacking, the authors are conducting a retrospective cohort study of over 240 000 children in the UK who underwent CT scans. The main objective of the study is to quantify the magnitude of the cancer risk in relation to the radiation dose from CT scans. In this paper, the methods used to estimate typical organ-specific doses delivered by CT scans to children are described. An organ dose database from Monte Carlo radiation transport-based computer simulations using a series of computational human phantoms from newborn to adults for both male and female was established. Organ doses vary with patient size and sex, examination types and CT technical settings. Therefore, information on patient age, sex and examination type from electronic radiology information systems and technical settings obtained from two national surveys in the UK were used to estimate radiation dose. Absorbed doses to the brain, thyroid, breast and red bone marrow were calculated for reference male and female individuals with the ages of newborns, 1, 5, 10, 15 and 20 y for a total of 17 different scan types in the pre- and post-2001 time periods. In general, estimated organ doses were slightly higher for females than males which might be attributed to the smaller body size of the females. The younger children received higher doses in pre-2001 period when adult CT settings were typically used for children. Paediatric-specific adjustments were assumed to be used more frequently after 2001, since then radiation doses to children have often been smaller than those to adults. The database here is the first detailed organ-specific paediatric CT scan database for the UK. As well as forming the basis for the UK study, the results and description of the methods will also serve as a key resource for paediatric CT scan studies currently underway in other countries. PMID:22228685

  18. Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom.

    PubMed

    Kim, K P; Berrington de González, A; Pearce, M S; Salotti, J A; Parker, L; McHugh, K; Craft, A W; Lee, C

    2012-07-01

    Despite great potential benefits, there are concerns about the possible harm from medical imaging including the risk of radiation-related cancer. There are particular concerns about computed tomography (CT) scans in children because both radiation dose and sensitivity to radiation for children are typically higher than for adults undergoing equivalent procedures. As direct empirical data on the cancer risks from CT scans are lacking, the authors are conducting a retrospective cohort study of over 240,000 children in the UK who underwent CT scans. The main objective of the study is to quantify the magnitude of the cancer risk in relation to the radiation dose from CT scans. In this paper, the methods used to estimate typical organ-specific doses delivered by CT scans to children are described. An organ dose database from Monte Carlo radiation transport-based computer simulations using a series of computational human phantoms from newborn to adults for both male and female was established. Organ doses vary with patient size and sex, examination types and CT technical settings. Therefore, information on patient age, sex and examination type from electronic radiology information systems and technical settings obtained from two national surveys in the UK were used to estimate radiation dose. Absorbed doses to the brain, thyroid, breast and red bone marrow were calculated for reference male and female individuals with the ages of newborns, 1, 5, 10, 15 and 20 y for a total of 17 different scan types in the pre- and post-2001 time periods. In general, estimated organ doses were slightly higher for females than males which might be attributed to the smaller body size of the females. The younger children received higher doses in pre-2001 period when adult CT settings were typically used for children. Paediatric-specific adjustments were assumed to be used more frequently after 2001, since then radiation doses to children have often been smaller than those to adults. The database here is the first detailed organ-specific paediatric CT scan database for the UK. As well as forming the basis for the UK study, the results and description of the methods will also serve as a key resource for paediatric CT scan studies currently underway in other countries.

  19. Red Marrow-Absorbed Dose for Non-Hodgkin Lymphoma Patients Treated with 177Lu-Lilotomab Satetraxetan, a Novel Anti-CD37 Antibody-Radionuclide Conjugate.

    PubMed

    Blakkisrud, Johan; Løndalen, Ayca; Dahle, Jostein; Turner, Simon; Holte, Harald; Kolstad, Arne; Stokke, Caroline

    2017-01-01

    Red marrow (RM) is often the primary organ at risk in radioimmunotherapy; irradiation of marrow may induce short- and long-term hematologic toxicity. 177 Lu-lilotomab satetraxetan is a novel anti-CD37 antibody-radionuclide conjugate currently in phase 1/2a. Two predosing regimens have been investigated, one with 40 mg of unlabeled lilotomab antibody (arm 1) and one without (arm 2). The aim of this work was to compare RM-absorbed doses for the two arms and to correlate absorbed doses with hematologic toxicity. Eight patients with relapsed CD37+ indolent B-cell non-Hodgkin lymphoma were included for RM dosimetry. Hybrid SPECT and CT images were used to estimate the activity concentration in the RM of L2-L4. Pharmacokinetic parameters were calculated after measurement of the 177 Lu-lilotomab satetraxetan concentration in blood samples. Adverse events were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The mean absorbed doses to RM were 0.9 mGy/MBq for arm 1 (lilotomab+) and 1.5 mGy/MBq for arm 2 (lilotomab-). There was a statistically significant difference between arms 1 and 2 (Student t test, P = 0.02). Total RM-absorbed doses ranged from 67 to 127 cGy in arm 1 and from 158 to 207 cGy in arm 2. For blood, the area under the curve was higher with lilotomab predosing than without (P = 0.001), whereas the volume of distribution and the clearance of 177 Lu-lilotomab satetraxetan was significantly lower (P = 0.01 and P = 0.03, respectively). Patients with grade 3/4 thrombocytopenia had received significantly higher radiation doses to RM than patients with grade 1/2 thrombocytopenia (P = 0.02). A surrogate, non-imaging-based, method underestimated the RM dose and did not show any correlation with toxicity. Predosing with lilotomab reduces the RM-absorbed dose for 177 Lu-lilotomab satetraxetan patients. The decrease in RM dose could be explained by the lower volume of distribution. Hematologic toxicity was more severe for patients receiving higher absorbed radiation doses, indicating that adverse events possibly can be predicted by the calculation of absorbed dose to RM from SPECT/CT images. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  20. The comparison of high and standard definition computed tomography techniques regarding coronary artery imaging.

    PubMed

    Aykut, Aktas; Bumin, Degirmenci; Omer, Yilmaz; Mustafa, Kayan; Meltem, Cetin; Orhan, Celik; Nisa, Unlu; Hikmet, Orhan; Hakan, Demirtas; Mert, Koroglu

    2015-09-01

    The aim was to compare coronary high-definition CT (HDCT) with standard-definition CT (SDCT) angiography as to radiation dose, image quality and accuracy. 28 patients with history of coronary artery disease scanned by HDCT (Discovery CT750 HD) and SDCT (Somatom Definition AS). The scan modes were both axial prospective ECG-triggered. The vessel diameters and vessel attenuation values of totally 280 measurements from 140 coronary arteries were analyzed by two experienced radiologists. All data was analyzed by intraclass correlation test. Image quality graded by motion and stair step artifacts (grade 1, poor, to grade 4, excellent), accuracy of vessel inner and outer diameters were compared between the two CT units using the independent samples t-test and Mann-Whitney U test. The intraclass correlation coefficient (ICC) of measured vessel attenuation values in SDCT between the two radiologists was exceedingly good. The ICC was higher in HDCT. The radiation dose of HDCT was higher than that of SDCT. The mean tube current was 180 (mA) in HDCT and 147(mA) in SDCT with the same tube voltage (kVp). There was no significant difference between image quality. HDCT has a higher radiation dose but has much more atenuation and the spatial resolution which improve measurement accuracy for imaging coronary arteries.

  1. Influence of Al³⁺ addition on the flocculation and sedimentation of activated sludge: comparison of single and multiple dosing patterns.

    PubMed

    Wen, Yue; Zheng, Wanlin; Yang, Yundi; Cao, Asheng; Zhou, Qi

    2015-05-15

    In this study, the flocculation and sedimentation performance of activated sludge (AS) with single and multiple dosing of trivalent aluminum (Al(3+)) were studied. The AS samples were cultivated in sequencing batch reactors at 22 °C. The dosages of Al(3+) were 0.00, 0.125, 0.5, 1.0, and 1.5 meq/L for single dosing, and 0.1 meq/L for multiple dosing. Under single dosing conditions, as Al(3+) dosage increased, the zeta potential, total interaction energy, and effluent turbidity decreased, whereas the sludge volume index (SVI) increased, indicating that single Al(3+) dosing could enhance sludge flocculation, but deteriorate sedimentation. By comparison, adding an equal amount of Al(3+) through multiple dosing achieved a similar reduction in turbidity, but the zeta potential was higher, while the loosely bound extracellular polymeric substances (LB-EPS) content and SVI remarkably declined. Although the difference in the flocculation performances between the two dosing patterns was not significant, the underlying mechanisms were quite distinct: the interaction energy played a more important role under single dosing conditions, whereas multiple dosing was more effective in reducing the EPS content. Multiple dosing, which allows sufficient time for sludge restructuring and floc aggregation, could simultaneously optimize sludge flocculation and sedimentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Dose and dose rate effects of whole-body proton-irradiation on lymphocyte blastogenesis and hematological variables: part II

    NASA Technical Reports Server (NTRS)

    Pecaut, Michael J.; Gridley, Daila S.; Smith, Anna L.; Nelson, Gregory A.

    2002-01-01

    The goal of part II of this study was to evaluate functional characteristics of leukocytes and circulating blood cell parameters after whole-body proton irradiation at varying doses and at low- and high-dose-rates (LDR and HDR, respectively). C57BL/6 mice (n=51) were irradiated and euthanized at 4 days post-exposure for assay. Significant radiation dose- (but not dose-rate-) dependent decreases were observed in splenocyte responses to T and B cell mitogens when compared to sham-irradiated controls (P<0.001). Spontaneous blastogenesis, also significantly dose-dependent, was increased in both blood and spleen (P<0.001). Red blood cell counts, hemoglobin concentration, and hematocrit were decreased in a dose-dependent manner (P<0.05), whereas thrombocyte numbers were only slightly affected. Comparison of proton- and gamma-irradiated groups (both receiving 3 Gy at HDR) showed a higher level of spontaneous blastogenesis in blood leukocytes and a lower splenocyte response to concanavalin A following proton irradiation (P<0.05). There were no dose rate effects. Collectively, the data demonstrate that the measurements in blood and spleen were largely dependent upon the total dose of proton radiation and that an 80-fold difference in the dose rate was not a significant factor. A difference, however, was found between protons and gamma-rays in the degree of change induced in some of the measurements.

  3. Radiation dose- and sex-dependent cardiovascular mortality in residents of contaminated areas after the Chornobyl NPP accident, 1988-2010 observation period.

    PubMed

    Buzunov, V O; Prikaschikova, K Ye; Gubina, I G; Kostiuk, G V; Tereschenko, S O

    2013-01-01

    To estimate the circulatory system disease death rates for people living in areas contaminated after the Chornobyl accident. Epidemiological estimation covered the post-accident period (1988-2010) and was focused on the relationship between death rates and doses accumulated over 1986-2010 or sex of survivors aged under 60 at the time of the accident. We used data from the State Registry of Ukraine on persons affected by the Chornobyl accident. Residents of contaminated areas were grouped into the two cohorts according to cumulative dose values. Cohort 1 numbered 155,592 people (86,787 females and 68,805 males), their radiation doses were 5.6-20.99 mSv; cohort 2 totaled 98,830 people (52,640 females and 46,190 males) with radiation doses 21.00-50.99 mSv. Mean age (X ± δ) of inhabitants of contaminated areas at the time of the accident (April 26, 1986) was 29.5 ± 23.2 years (30.6 ± 22.3 for women and 28.3 ± 23.2 for men) in the cohort 1, and 28.7 ± 17.3 years (29.8 ± 17.7 and 27.5 ± 16.2 respectively) in the cohort 2). These cohorts were subdivided by sex (males and females). Significantly higher (ID per 103 person-years is 8.08 ± 0.10) cardiovascular mortality was revealed among members of the cohort 2 vs. cohort 1 (ID per 103 person-years is 6.29 ± 0.06). Mortality from cardiovascular diseases in both sex groups of the cohort 2 is higher (ID per 103 person-years is 6.80 ± 0.12 in women and 9.43 ± 0.15 - in men) than that of the cohort 1 (ID per 103 person-years is 5.34 ± 0.08 in women, 7.37 ± 0.10 - in men). Whatever accumulated doses the mortality from circulatory diseases was significantly higher in men vs. women. Cardiovascular mortality in population of radiation-contaminated territories depends on the integral radiation exposure and gender. Death rates are clearly higher (p<0.05) in persons having more radiation doses vs. those exposed to less ones. Mortality is significantly higher in males vs. females despite integral radiation doses values. The coronary heart disease, cerebrovascular disease, arterial hypertension, heart diseases, diseases of arteries, arterioles and capillaries) were the main causes of death. Buzunov V. O., Prykashhykova K. Je., Gubina I. G., Kostjuk G. V., Tereshhenko S. O., 2013.

  4. Comparison of Omadacycline and Tigecycline Pharmacokinetics in the Plasma, Epithelial Lining Fluid, and Alveolar Cells of Healthy Adult Subjects.

    PubMed

    Gotfried, Mark H; Horn, Karolyn; Garrity-Ryan, Lynne; Villano, Stephen; Tzanis, Evan; Chitra, Surya; Manley, Amy; Tanaka, S Ken; Rodvold, Keith A

    2017-09-01

    The steady-state concentrations of omadacycline and tigecycline in the plasma, epithelial lining fluid (ELF), and alveolar cells (AC) of 58 healthy adult subjects were obtained. Subjects were administered either omadacycline at 100 mg intravenously (i.v.) every 12 h for two doses followed by 100 mg i.v. every 24 h for three doses or tigecycline at an initial dose of 100 mg i.v. followed by 50 mg i.v. every 12 h for six doses. A bronchoscopy and bronchoalveolar lavage were performed once in each subject following the start of the fifth dose of omadacycline at 0.5, 1, 2, 4, 8, 12, or 24 h and after the start of the seventh dose of tigecycline at 2, 4, 6, or 12 h. The value of the area under the concentration-time curve (AUC) from time zero to 24 h postdosing (AUC 0-24 ) (based on mean concentrations) in ELF and the ratio of the ELF to total plasma omadacycline concentration based on AUC 0-24 values were 17.23 mg · h/liter and 1.47, respectively. The AUC 0-24 value in AC was 302.46 mg · h/liter, and the ratio of the AC to total plasma omadacycline concentration was 25.8. In comparison, the values of the AUC from time zero to 12 h postdosing (AUC 0-12 ) based on the mean concentrations of tigecycline in ELF and AC were 3.16 and 38.50 mg · h/liter, respectively. The ratio of the ELF and AC to total plasma concentrations of tigecycline based on AUC 0-12 values were 1.71 and 20.8, respectively. The pharmacokinetic advantages of higher and sustained concentrations of omadacycline compared to those of tigecycline in plasma, ELF, and AC suggest that omadacycline is a promising antibacterial agent for the treatment of lower respiratory tract bacterial infections caused by susceptible pathogens. Copyright © 2017 Gotfried et al.

  5. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  6. Theoretical study of the influence of a heterogeneous activity distribution on intratumoral absorbed dose distribution.

    PubMed

    Bao, Ande; Zhao, Xia; Phillips, William T; Woolley, F Ross; Otto, Randal A; Goins, Beth; Hevezi, James M

    2005-01-01

    Radioimmunotherapy of hematopoeitic cancers and micrometastases has been shown to have significant therapeutic benefit. The treatment of solid tumors with radionuclide therapy has been less successful. Previous investigations of intratumoral activity distribution and studies on intratumoral drug delivery suggest that a probable reason for the disappointing results in solid tumor treatment is nonuniform intratumoral distribution coupled with restricted intratumoral drug penetrance, thus inhibiting antineoplastic agents from reaching the tumor's center. This paper describes a nonuniform intratumoral activity distribution identified by limited radiolabeled tracer diffusion from tumor surface to tumor center. This activity was simulated using techniques that allowed the absorbed dose distributions to be estimated using different intratumoral diffusion capabilities and calculated for tumors of varying diameters. The influences of these absorbed dose distributions on solid tumor radionuclide therapy are also discussed. The absorbed dose distribution was calculated using the dose point kernel method that provided for the application of a three-dimensional (3D) convolution between a dose rate kernel function and an activity distribution function. These functions were incorporated into 3D matrices with voxels measuring 0.10 x 0.10 x 0.10 mm3. At this point fast Fourier transform (FFT) and multiplication in frequency domain followed by inverse FFT (iFFT) were used to effect this phase of the dose calculation process. The absorbed dose distribution for tumors of 1, 3, 5, 10, and 15 mm in diameter were studied. Using the therapeutic radionuclides of 131I, 186Re, 188Re, and 90Y, the total average dose, center dose, and surface dose for each of the different tumor diameters were reported. The absorbed dose in the nearby normal tissue was also evaluated. When the tumor diameters exceed 15 mm, a much lower tumor center dose is delivered compared with tumors between 3 and 5 mm in diameter. Based on these findings, the use of higher beta-energy radionuclides, such as 188Re and 90Y is more effective in delivering a higher absorbed dose to the tumor center at tumor diameters around 10 mm.

  7. Determinants of Diuretic Responsiveness and Associated Outcomes During Acute Heart Failure Hospitalization: An Analysis From the NHLBI Heart Failure Network Clinical Trials.

    PubMed

    Kiernan, Michael S; Stevens, Susanna R; Tang, W H Wilson; Butler, Javed; Anstrom, Kevin J; Birati, Edo Y; Grodin, Justin L; Gupta, Divya; Margulies, Kenneth B; LaRue, Shane; Dávila-Román, Victor G; Hernandez, Adrian F; de Las Fuentes, Lisa

    2018-03-01

    Poor response to loop diuretic therapy is a marker of risk during heart failure hospitalization. We sought to describe baseline determinants of diuretic response and to further explore the relationship between this response and clinical outcomes. Patient data from the National Heart, Lung, and Blood Institute Heart Failure Network ROSE-AHF and CARRESS-HF clinical trials were analyzed to determine baseline determinants of diuretic response. Diuretic efficiency (DE) was defined as total 72-hour fluid output per total equivalent loop diuretic dose. Data from DOSE-AHF was then used to determine if these predictors of DE correlated with response to a high- versus low-dose diuretic strategy. At 72 hours, the high-DE group had median fluid output of 9071 ml (interquartile range: 7240-11775) with median furosemide dose of 320 mg (220-480) compared with 8030 ml (6300-9915) and 840 mg (600-1215) respectively for the low DE group. Cystatin C was independently associated with DE (odds ratio 0.36 per 1mg/L increase; 95% confidence interval: 0.24-0.56; P < 0.001). Independently from baseline characteristics, reduced fluid output, weight loss and DE were each associated with increased 60 day mortality. Among patients with estimated glomerular filtration rate below the median, those randomized to a high-dose strategy had improved symptoms compared with those randomized to a low-dose strategy. Elevated baseline cystatin C, as a biomarker of renal dysfunction, is associated with reduced diuretic response during heart failure hospitalization. Higher loop diuretic doses are required for therapeutic decongestion in patients with renal insufficiency. Poor response identifies a high-risk population. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Impact on dose and image quality of a software-based scatter correction in mammography.

    PubMed

    Monserrat, Teresa; Prieto, Elena; Barbés, Benigno; Pina, Luis; Elizalde, Arlette; Fernández, Belén

    2018-06-01

    Background In 2014, Siemens developed a new software-based scatter correction (Progressive Reconstruction Intelligently Minimizing Exposure [PRIME]), enabling grid-less digital mammography. Purpose To compare doses and image quality between PRIME (grid-less) and standard (with anti-scatter grid) modes. Material and Methods Contrast-to-noise ratio (CNR) was measured for various polymethylmethacrylate (PMMA) thicknesses and dose values provided by the mammograph were recorded. CDMAM phantom images were acquired for various PMMA thicknesses and inverse Image Quality Figure (IQF inv ) was calculated. Values of incident entrance surface air kerma (ESAK) and average glandular dose (AGD) were obtained from the DICOM header for a total of 1088 pairs of clinical cases. Two experienced radiologists compared subjectively the image quality of a total of 149 pairs of clinical cases. Results CNR values were higher and doses were lower in PRIME mode for all thicknesses. IQF inv values in PRIME mode were lower for all thicknesses except for 40 mm of PMMA equivalent, in which IQF inv was slightly greater in PRIME mode. A mean reduction of 10% in ESAK and 12% in AGD in PRIME mode with respect to standard mode was obtained. The clinical image quality in PRIME and standard acquisitions resulted to be similar in most of the cases (84% for the first radiologist and 67% for the second one). Conclusion The use of PRIME software reduces, in average, the dose of radiation to the breast without affecting image quality. This reduction is greater for thinner and denser breasts.

  9. Morphine decreases social interaction of adult male rats, while THC does not affect it.

    PubMed

    Šlamberová, R; Mikulecká, A; Macúchová, E; Hrebíčková, I; Ševčíková, M; Nohejlová, K; Pometlová, M

    2016-12-22

    The aim of the present study was to compare effect of three low doses of morphine (MOR) and delta9-tetrahydrocannabinol (THC) on social behavior tested in Social interaction test (SIT). 45 min prior to testing adult male rats received one of the drugs or solvents: MOR (1; 2.5; 5 mg/kg); saline as a solvent for MOR; THC (0.5; 1; 2 mg/kg); ethanol as a solvent for THC. Occurrence and time spent in specific patterns of social interactions (SI) and non-social activities (locomotion and rearing) was video-recorded for 5 min and then analyzed. MOR in doses of 1 and 2.5 mg/kg displayed decreased SI in total. Detailed analysis of specific patterns of SI revealed decrease in mutual sniffing and allo-grooming after all doses of MOR. The highest dose (5 mg/kg) of MOR decreased following and increased genital investigation. Rearing activity was increased by lower doses of MOR (1 and 2.5 mg/kg). THC, in each of the tested doses, did not induce any specific changes when compared to matching control group (ethanol). However, an additional statistical analysis showed differences between all THC groups and their ethanol control group when compared to saline controls. There was lower SI in total, lower mutual sniffing and allo-grooming, but higher rearing in THC and ethanol groups than in saline control group. Thus, changes seen in THC and ethanol groups are seemed to be attributed mainly to the effect of the ethanol. Based on the present results we can assume that opioids affect SI more than cannabinoid.

  10. Comparison of effect of 5 MeV proton and Co-60 gamma irradiation on silicon NPN rf power transistors and N-channel depletion MOSFETs

    NASA Astrophysics Data System (ADS)

    Gnana Prakash, A. P.; Pradeep, T. M.; Hegde, Vinayakprasanna N.; Pushpa, N.; Bajpai, P. K.; Patel, S. P.; Trivedi, Tarkeshwar; Bhushan, K. G.

    2017-12-01

    NPN transistors and N-channel depletion metal oxide semiconductor field effect transistors (MOSFETs) were irradiated with 5 MeV protons and 60Co gamma radiation in the dose ranging from 1 Mrad(Si) to 100 Mrad(Si). The different electrical characteristics of the NPN transistor such as Gummel characteristics, excess base current (ΔIB), dc current gain (hFE), transconductance (gm), displacement damage factor (K) and output characteristics were studied as a function of total dose. The different electrical characteristics of N-channel MOSFETs such as threshold voltage (Vth), density of interface trapped charges (ΔNit), density of oxide trapped charges (ΔNot), transconductance (gm), mobility (µ) and drain saturation current (IDSat) were studied systematically before and after irradiation in the same dose ranges. A considerable increase in the base current (IB) and decrease in the hFE, gm and collector saturation current (ICSat) were observed after irradiation in the case of the NPN transistor. In the N-channel MOSFETs, the ΔNit and ΔNot were found to increase and Vth, gm, µ and IDSat were found to decrease with increase in the radiation dose. The 5 MeV proton irradiation results of both the NPN transistor and N-channel MOSFETs were compared with 60Co gamma-irradiated devices in the same dose ranges. It was observed that the degradation in 5 MeV proton-irradiated devices is more when compared with the 60Co gamma-irradiated devices at higher total doses.

  11. Vedolizumab Pharmacokinetics, Pharmacodynamics, Safety, and Tolerability Following Administration of a Single, Ascending, Intravenous Dose to Healthy Volunteers.

    PubMed

    Rosario, Maria; Wyant, Timothy; Leach, Timothy; Sankoh, Serap; Scholz, Catherine; Parikh, Asit; Fox, Irving; Feagan, Brian G

    2016-11-01

    Vedolizumab, a humanized monoclonal antibody against the α 4 β 7 integrin, is indicated for treatment of moderately to severely active ulcerative colitis or Crohn's disease. In this placebo-controlled, double-blind, randomized, single ascending-dose study, the pharmacokinetics, pharmacodynamics, safety, and tolerability of vedolizumab were evaluated in healthy volunteers. Forty-nine participants (in five cohorts) were randomly assigned in a 4:1 ratio to receive a single intravenous infusion of either vedolizumab (0.2, 0.5, 2.0, 6.0, or 10.0 mg/kg) or placebo. Blood samples were collected for measurement of vedolizumab serum concentrations and α 4 β 7 saturation on peripheral blood lymphocytes by vedolizumab. Pharmacokinetic parameters were computed using a non-compartmental approach. Adverse events were monitored. Vedolizumab maximum observed serum concentration (C max ) demonstrated dose proportionality over the dose range tested. Greater than dose-proportional increases in area under the serum concentration-time curve from time 0 to infinity (AUC 0-inf ) and shorter terminal elimination half-life (t 1/2 ) were observed from 0.2 to 2.0 mg/kg, suggestive of nonlinear pharmacokinetics at lower doses. At doses higher than 2.0 mg/kg, these parameters increased dose proportionally. Saturation of α 4 β 7 was at or near maximal levels (>90 %) at all doses and time points when vedolizumab was measurable in serum. A total of 21 of 39 (54 %) vedolizumab-treated participants were anti-drug antibody (ADA) positive, and 11 (28 %) were persistently ADA positive. Overall, no adverse event signals, including serious infections or malignancies, were apparent. Vedolizumab exhibited target-mediated disposition, characterized by a rapid, saturable, nonlinear elimination process at low concentrations and a slower linear elimination process at higher concentrations. Nearly complete α 4 β 7 saturation was observed at all doses. A single intravenous infusion of vedolizumab was well tolerated by healthy volunteers.

  12. Pigmentation after single and multiple UV-exposures depending on UV-spectrum.

    PubMed

    Ravnbak, M H; Wulf, H C

    2007-04-01

    Minimal pigmentation dose (MMD) after a single UV-exposure is well investigated. Whereas only few studies have established MMD after multiple UV-exposures and mainly in fair-skinned persons. The purpose of this study was to establish MMD 1 week after, respectively, one and five UV-exposures in volunteers with a large variation in constitutive pigmentation. A total of 52 volunteers (skin Types II-V) had skin pigmentation quantified by reflectance spectroscopy. They were UV-exposed on the back for 1 and 5 days using a Solar Simulator, narrowband UVB, broadband UVA and UVA1. For all sources a higher dose was needed the more pigmented the skin, except for UVA1. After one UV-exposure, we found a significant positive linear correlation between UV-dose to one MMD, skin type and pre-exposure skin pigmentation. After five UV-exposures the positive linear correlation between UV-dose and MMD and skin type was only significant for narrow band UVB, pre-exposure skin pigmentation was significant also for Solar Simulator. For UVA and particularly UVA1 the MMD was independent of pre-exposure pigmentation. The number of SED to MMD is therefore almost the same for very fair-skinned and dark-skinned persons. Pre-exposure pigmentation was clearly more predictive of MMD than skin type. 50% of MMD equals a pigmentation increase of 1%. The shorter the wavelengths the higher the SED to produce MMD. Solar was the least melanogenic and UVA1 the most melanogenic. For the UVB-sources a higher dose was needed the more pigmented the skin. For UVA the MMD was independent of pre-exposure pigmentation.

  13. [Dose-Response Dependences for Frequency of RET/PTC Gene Rearrangements in Papillary Thyroid Carcinoma after Irradiation. Simple Pooling Analysis of Molecular Epidemiological Data].

    PubMed

    Koterov, A N; Ushenkova, L N; Biryukov, A P

    2016-01-01

    On the basis of all possible publications on the theme included in the previously formed base of sources on molecular epidemiology of RET/PTC rearrangements in thyroid papillary carcinoma a pooled analysis ("simple pooling data") on determination of the dose-effect dependences for RET/PTC frequency in radiogenic carcinomas of various irradiated groups was performed. (They are groups subjected to radiotherapeutic exposure, residents near the Chernobyl nuclear power plant (CNPP) and victims of nuclear bombing). The tendency to Pearson linear correlation (r = 0.746; p = 0.148) between the frequency of RET/PTC and the estimated dose on thyroid in the regions affected by the CNPP accident was revealed. But this tendency was recognized to be random owing to abnormally low values of the indicator for the most contaminated Gomel region. The method tentatively called "case-control" showed reliable differences in thyroid dose values for carcinomas with RET/PTC and without those. The versatility of changes was found: the lack of RET/PTC for radiotherapeutic impacts was associated with higher doses, whereas in case of the CNPP accident and for nuclear bombing victims it was the opposite. Probably, in the first case the "cellular cleaning" phenomenon after exposure to very high doses took place. Search of direct Pearson correlations between average/median thyroid doses on groups and RET/PTC frequency in carcinomas of these groups showed a high reliability for the dose-effect dependences- at the continuous dose scale (for RET/PTC in total and RET/PTC1 respectively: r = 0.830; p = 0.002 and r = 0.906; p = 0.0003); while there was no significant correlation received for RET/PTC3. When using the weighting least square regression analysis (proceeding from the number of carcinomas in samples), the specified regularities remained. Attempts to influence the strength of correlation by exception ofthe data of all the samples connected with the accident on the CNPP did not significantly reduce the strength of associations for RET/PTC in total. On the basis of ordinal scale doses (background, "low" (0.1 Gy), "middle" (0.1-1 Gy) and "large" (1-10 Gy) dose) also found was a significant correlation (Spearman) with the dose for the frequency RET/PTC in total (r = 0.736; p = 0.0098), but for certain types of rearrangements the results were reverse to the previous analysis (the effect was significant only for the RET/PTC3: r = 0.731; p = 0.024). The linear dose-response trends of the Cochrane-Armitage-test for the frequency of RET/PTC in total, RET/PTC1 and RET/PTC3 depending on the dose to the thyroid in the ordinal scale were registered (p, respectively: < 0.0001 < 0.0001 and 0.007). Thus; after more than 20 years of the molecular and epidemiological research of RET/PTC in thyroid radiogenic carcinomas the comprehensive evidence of the dose-effect dependence existence indicating a real relationship between the studied parameters and a radiation factor was obtained for the first time.

  14. Physical activity and incident type 2 diabetes mellitus: a systematic review and dose-response meta-analysis of prospective cohort studies.

    PubMed

    Smith, Andrea D; Crippa, Alessio; Woodcock, James; Brage, Søren

    2016-12-01

    Inverse associations between physical activity (PA) and type 2 diabetes mellitus are well known. However, the shape of the dose-response relationship is still uncertain. This review synthesises results from longitudinal studies in general populations and uses non-linear models of the association between PA and incident type 2 diabetes. A systematic literature search identified 28 prospective studies on leisure-time PA (LTPA) or total PA and risk of type 2 diabetes. PA exposures were converted into metabolic equivalent of task (MET) h/week and marginal MET (MMET) h/week, a measure only considering energy expended above resting metabolic rate. Restricted cubic splines were used to model the exposure-disease relationship. Our results suggest an overall non-linear relationship; using the cubic spline model we found a risk reduction of 26% (95% CI 20%, 31%) for type 2 diabetes among those who achieved 11.25 MET h/week (equivalent to 150 min/week of moderate activity) relative to inactive individuals. Achieving twice this amount of PA was associated with a risk reduction of 36% (95% CI 27%, 46%), with further reductions at higher doses (60 MET h/week, risk reduction of 53%). Results for the MMET h/week dose-response curve were similar for moderate intensity PA, but benefits were greater for higher intensity PA and smaller for lower intensity activity. Higher levels of LTPA were associated with substantially lower incidence of type 2 diabetes in the general population. The relationship between LTPA and type 2 diabetes was curvilinear; the greatest relative benefits are achieved at low levels of activity, but additional benefits can be realised at exposures considerably higher than those prescribed by public health recommendations.

  15. The effects of cadmium pulse dosing on physiological traits and growth of the submerged macrophyte Vallisneria spinulosa and phytoplankton biomass: a mesocosm study.

    PubMed

    Liu, Hui; Cao, Yu; Li, Wei; Zhang, Zhao; Jeppesen, Erik; Wang, Wei

    2017-06-01

    Pulse inputs of heavy metals are expected to increase with a higher frequency of extreme climate events (heavy rain), leading to stronger erosion of contaminated and fertilized farmland soils to freshwaters, with potentially adverse effects on lake ecosystems. We conducted a 5-month mesocosm study to elucidate the responses of the submerged macrophyte Vallisneria spinulosa and phytoplankton to four different doses of cadmium (Cd): 0 (control), 0.05, 0.5, and 5 g m -2 (CK, I, II, and III, respectively) under mesotrophic conditions. We found that total phosphorus concentrations were larger in the three Cd pulse treatments, whereas total nitrogen concentrations did not differ among the four treatments. The contents of chlorophyll a and soluble sugar in macrophyte leaves decreased in III, and total biomass, ramet number, plant height, and total stolon length of macrophytes were lower in both II and III. In contrast, abundances of the three main phytoplankton taxa-Cyanophyta, Chlorophyta, and Bacillariophyta-did not differ among treatments. Total phytoplankton biomass was, however, marginally lower in CK than in the Cd treatments. We conclude that exposure to strong Cd pulses led to significantly reduced growth of macrophytes, while no obvious effect appeared for phytoplankton.

  16. The effect of replacing lactose by starch on protein and fat digestion in milk-fed veal calves.

    PubMed

    Pluschke, A M; Gilbert, M S; Williams, B A; van den Borne, J J G C; Schols, H A; Gerrits, W J J

    2016-08-01

    Replacing dairy components from milk replacer (MR) with vegetable products has been previously associated with decreased protein and fat digestibility in milk-fed calves resulting in lower live weight gain. In this experiment, the major carbohydrate source in MR, lactose, was partly replaced with gelatinized corn starch (GCS) to determine the effect on protein and fat digestibility in milk-fed calves. In total, 16 male Holstein-Friesian calves received either MR with lactose as the carbohydrate source (control) or 18% GCS at the expense of lactose. In the adaptation period, calves were exposed to an increasing dose of GCS for 14 weeks. The indigestible marker cobalt ethylenediaminetetraacetic acid was incorporated into the MR for calculating apparent nutrient digestibility, whereas a pulse dose of chromium (Cr) chloride was fed with the last MR meal 4 h before slaughter as an indicator of passage rates. The calves were anesthetized and exsanguinated at 30 weeks of age. The small intestine was divided in three; small intestine 1 and 2 (SI1 and SI2, respectively) and the terminal ileum (last ~100 cm of small intestine) and samples of digesta were collected. Small intestinal digesta was analysed for α-amylase, lipase and trypsin activity. Digestibility of protein was determined for SI1, SI2, ileum and total tract, whereas digestibility of fat was determined for SI1, SI2 and total tract. Apparent protein digestibility in the small intestine did not differ between treatments but was higher in control calves at total tract level. Apparent crude fat digestibility tended to be increased in SI1 and SI2 for GCS calves, but no difference was found at total tract level. Activity of α-amylase in SI2 and lipase in both SI1 and SI2 was higher in GCS calves. Activity of trypsin tended to be higher in control calves and was higher in SI1 compared with SI2. A lower recovery of Cr in SI2 and a higher recovery of Cr in the large intestine suggest an increased rate of passage for GCS calves. Including 18% of GCS in a milk replacer at the expense of lactose increased passage rate and decreased apparent total tract protein digestibility. In the small intestine, protein digestion did not decrease when feeding GCS and fat digestion even tended to increase. Overall, effects on digestion might be levelled when partially replacing lactose with GCS, because starch digestion is lower than that of lactose but fat digestion may be slightly increased when feeding GCS.

  17. Decreased health-related quality of life in children and adolescents with autoimmune hepatitis.

    PubMed

    Bozzini, Ana Beatriz; Neder, Luciana; Silva, Clovis A; Porta, Gilda

    2018-01-10

    The objective of this study was to evaluate the health-related quality of life in children and adolescents with autoimmune hepatitis. A cross-sectional assessment with the Pediatric Quality of Life Inventory 4.0 (PedsQL 4.0) was completed for 80 patients with autoimmune hepatitis and 45 healthy controls. Demographic data, prednisone dose, disease remission state, disease severity, and abdominal pain were also evaluated. Based on the child self-reports, physical, emotional, school, and total scores were significantly lower in autoimmune hepatitis patients when compared with controls (p<0.05). Based on the parental reports, only the physical and total scores were significantly lower in autoimmune hepatitis patients versus controls (p<0.05). Further analysis in autoimmune hepatitis patients with abdominal pain in the last month revealed significantly lower physical, social, and total median scores (p<0.05). No differences were observed based on disease remission state or disease severity (p>0.05). Autoimmune hepatitis patients who received a prednisone dose below 0.16mg/kg/day at the time of the interview showed significantly higher physical scores than those who received a dose similar to or above 0.16mg/kg/day (87.5 [50-100] vs. 75 [15.63-100], p=0.006). Reduced scores in the physical, emotional, and school domains were observed in pediatric autoimmune hepatitis patients compared to control patients. Abdominal pain and corticosteroid dose negatively influenced the health-related quality of life in children and adolescents with autoimmune hepatitis. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  18. Risks of secondary malignancies with heterotopic bone radiation therapy for patients younger than 40 years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadieux, Catherine L., E-mail: ccadieux@umail.iu.edu; DesRosiers, Colleen; McMullen, Kevin

    Heterotopic ossification (HO) of the bone is defined as a benign condition in which abnormal bone formation occurs in soft tissue. One of the most common prophylactic treatments for HO is radiation therapy (RT). This study retrospectively reviewed 20 patients younger than the age of 40 who received radiation to prevent HO in a single fraction of 7 Gray. The purpose of this study is to assess the risk of a second malignancy in these patients by recreating their treatment fields and contouring organs at risk to estimate the radiation dose absorbed by normal tissues outside the radiation treatment field.more » Diagnostic computed tomography (CT) scans for each patient were used to recreate treatment fields and to calculate dose to structures of interest. The distance from the field edge to each structure and its depth was recorded. Dose measurements in a water phantom were performed for the range of depths, distances, and field sizes used in the actual treatment plans. Computer-generated doses were compared to estimates based on measurement. The structure dose recorded was the higher dose generated between the 2 methods. Scatter dose was recorded to the rectum, bladder, sigmoid colon, small bowel, ovaries and utero-cervix in female patients, and prostate and gonads in male patients. In some patients, there is considerable dose received by certain organs from scatter because of their proximity to the radiation field. The average dose to the ovarian region was 4.125 Gy with a range of 1.085 to 6.228 Gy. The risk estimate for these patients ranged from 0.16% to 0.93%. The average total lifetime risk estimate for the bladder in all patients is 0.22% and the average total lifetime risk estimate for the remainder organs in all patients is 1.25%. In conclusions, proper shielding created from multileaf collimators (MLCs), blocks, and shields should always be used when possible.« less

  19. Safety and pharmacodynamics of venetoclax (ABT-199) in a randomized single and multiple ascending dose study in women with systemic lupus erythematosus.

    PubMed

    Lu, P; Fleischmann, R; Curtis, C; Ignatenko, S; Clarke, S H; Desai, M; Wong, S L; Grebe, K M; Black, K; Zeng, J; Stolzenbach, J; Medema, J K

    2018-02-01

    Objective The anti-apoptotic protein B-cell lymphoma 2 (Bcl-2) may contribute to the pathogenesis of systemic lupus erythematosus. The safety, tolerability, and pharmacodynamics of the selective Bcl-2 inhibitor venetoclax (ABT-199) were assessed in women with systemic lupus erythematosus. Methods A phase 1, double-blind, randomized, placebo controlled study evaluated single ascending doses (10, 30, 90, 180, 300, and 500 mg) and multiple ascending doses (2 cycles; 30, 60, 120, 240, 400, and 600 mg for 1 week, and then 3 weeks off per cycle) of orally administered venetoclax. Eligible participants were aged 18-65 years with a diagnosis of systemic lupus erythematosus for 6 months or more receiving stable therapy for systemic lupus erythematosus (which could have included corticosteroids and/or stable antimalarials). Results All patients (48/48) completed the single ascending dose, 25 continued into the multiple ascending dose, and 44/50 completed the multiple ascending dose; two of the withdrawals (venetoclax 60 mg and 600 mg cohorts) were due to adverse events. Adverse event incidences were slightly higher in the venetoclax groups compared with the placebo groups, with no dose dependence. There were no serious adverse events with venetoclax. The most common adverse events were headache, nausea, and fatigue. Venetoclax 600 mg multiple ascending dose treatment depleted total lymphocytes and B cells by approximately 50% and 80%, respectively. Naive, switched memory, and memory B-cell subsets enriched in autoreactive B cells exhibited dose-dependent reduction of up to approximately 80%. There were no consistent or marked changes in neutrophils, natural killer cells, hemoglobin, or platelets. Conclusions Venetoclax was generally well tolerated in women with systemic lupus erythematosus and reduced total lymphocytes and disease-relevant subsets of antigen-experienced B cells. Registration ClinicalTrials.gov: NCT01686555.

  20. TH-AB-202-09: Direct-Aperture Optimization for Combined MV+kV Dose Planning in Fluoroscopic Real-Time Tumor-Tracking Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, X; Belcher, AH; Grelewicz, Z

    Purpose: Real-time kV fluoroscopic tumor tracking has the benefit of direct tumor position monitoring. However, there is clinical concern over the excess kV imaging dose cost to the patient when imaging in continuous fluoroscopic mode. This work addresses this specific issue by proposing a combined MV+kV direct-aperture optimization (DAO) approach to integrate the kV imaging beam into a treatment planning such that the kV radiation is considered as a contributor to the overall dose delivery. Methods: The combined MV+kV DAO approach includes three algorithms. First, a projected Quasi-Newton algorithm (L-BFGS) is used to find optimized fluence with MV+kV dose formore » the best possible dose distribution. Then, Engel’s algorithm is applied to optimize the total number of monitor units and heuristically optimize the number of apertures. Finally, an aperture shape optimization (ASO) algorithm is applied to locally optimize the leaf positions of MLC. Results: Compared to conventional DAO MV plans with continuous kV fluoroscopic tracking, combined MV+kV DAO plan leads to a reduction in the total number of MV monitor units due to inclusion of kV dose as part of the PTV, and was also found to reduce the mean and maximum doses on the organs at risk (OAR). Compared to conventional DAO MV plan without kV tracking, the OAR dose in the combined MV+kV DAO plan was only slightly higher. DVH curves show that combined MV+kV DAO plan provided about the same PTV coverage as that in the conventional DAO plans without kV imaging. Conclusion: We report a combined MV+kV DAO approach that allows real time kV imager tumor tracking with only a trivial increasing on the OAR doses while providing the same coverage to PTV. The approach is suitable for clinic implementation.« less

  1. Selected heavy metals speciation in chemically stabilised sewage sludge

    NASA Astrophysics Data System (ADS)

    Wiśniowska, Ewa; Włodarczyk-Makuła, Marła

    2017-11-01

    Selected heavy metals (Pb, Ni, Cd) were analysed in soil, digested sewage sludge as well as in the sludge stabilised with CaO or Fenton's reagent. The dose of Fenton's reagent was as follows: Fe2+ = 1g.L-1, Fe2+/H2O2=1:100; stabilisation lasted for 2 h. Dose of CaO was equal to 1 g CaO.g d.m.-1 Total concentration of all metals in the digested sewage sludge was higher than in the soil. Chemical stabilisation of sludge with Fenton's reagent increased total metal content in the sludge as a result of total solids removal. Opposite effect was stated when the sludge was mixed with CaO. Also chemical fractions of heavy metals were identified (exchangeable, carbonate bound, iron oxides bound, organic and residual). The results indicate that stabilisation of the sludge with Fenton's reagent increased mobility of heavy metals compared to the digested sludge. Amendment of CaO increased percent share of examined metals in residual fraction, thus immobilised them and decreased their bioavailability.

  2. Public member dose assessment of Bushehr Nuclear Power Plant under normal operation by modeling the fallout from stack using the HYSPLIT atmospheric dispersion model.

    PubMed

    Zali, A; Shamsaei Zafarghandi, M; Feghhi, S A; Taherian, A M

    2017-05-01

    In this work, public dose resulting from fission products released from Bushehr Nuclear Power Plant (BNPP) under normal operation is assessed. Due to the long range transport of radionuclides in this work (80 km) and considering terrain and meteorological data, HYbrid Single-Particle Lagrangian Integrated Trajectory (HYsplit) model, which uses three dimensional long-range numerical models, has been employed to calculate atmospheric dispersion. Annual effective dose calculation is carried out for inhalation, ingestion, and external exposure pathways in 16directions and within 80 km around the site for representative person. The results showed the maximum dose of inhalation and external exposure for adults is 3.8 × 10 -8 Sv/y in the SE direction and distance of 600 m from the BNPP site which is less than ICRP 103 recommended dose limit (1 mSv). Children and infants' doses are higher in comparison with adults, although they are less than 1 mSv. Ingestion dose percentage in the total dose is less than 0.1%. The results of this study underestimate the Final Safety Analysis Report ofBNPP-1 (FSAR)data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Multi-scale simulation of radiation damage accumulation and subsequent hardening in neutron-irradiated α-Fe

    DOE PAGES

    Dunn, Aaron; Dingreville, Remi; Capolungo, Laurent

    2015-11-27

    A hierarchical methodology is introduced to predict the effects of radiation damage and irradiation conditions on the yield stress and internal stress heterogeneity developments in polycrystalline α-Fe. Simulations of defect accumulation under displacement cascade damage conditions are performed using spatially resolved stochastic cluster dynamics. The resulting void and dislocation loop concentrations and average sizes are then input into a crystal plasticity formulation that accounts for the change in critical resolved shear stress due to the presence of radiation induced defects. The simulated polycrystalline tensile tests show a good match to experimental hardening data over a wide range of irradiation doses.more » With this capability, stress heterogeneity development and the effect of dose rate on hardening is investigated. The model predicts increased hardening at higher dose rates for low total doses. By contrast, at doses above 10 –2 dpa when cascade overlap becomes significant, the model does not predict significantly different hardening for different dose rates. In conclusion, the development of such a model enables simulation of radiation damage accumulation and associated hardening without relying on experimental data as an input under a wide range of irradiation conditions such as dose, dose rate, and temperature.« less

  4. Comparative evaluation of hepatoprotective activity of carotenoids of microalgae.

    PubMed

    Murthy, K N Chidambara; Rajesha, J; Swamy, M Mahadeva; Ravishankar, G A

    2005-01-01

    The present study deals with evaluation of the hepatotoprotective activity of carotenoids from two well-known microalgae, Spirulina platensis and Dunaliella salina. Carotenoids were extracted in hexane:isopropyl alcohol (1:1 vol/vol) and fed orally in olive oil to Wistar albino rats at a dose of 100 microg/kg of body weight/day (in terms of carotenoids). The degree of hepatoprotection was measured by estimation of biochemical parameters like serum transaminases [serum glutamate oxaloacetate transaminase (SGOT) and serum glutamate pyruvate transaminase (SGPT)], serum alkaline phosphatase, total albumin, and total protein. The results were compared with those for a control group, a CCl4-induced hepatic damage group, and a group treated with synthetic beta-carotene (all-trans) at the same dose. The protein content of the CCl4-treated group, which received normal diet and a dose of toxin, showed a significant decrease, i.e., 3.92 mg/mL, whereas the protein levels were higher, i.e., 6.96 and 6.32 mg/mL, in the case of the Dunaliella and Spirulina, respectively, carotenoid-treated groups. The CCl4-treated group shown higher activity of transaminases (128.68 units/mL SGPT and 171.52 units/mL SGOT). However, the activity of SGPT was 62.83 units/mL for Dunaliella and 76.83 units/mL for Spirulina, i.e., carotenoids of Dunaliella showed a higher degree of protection. For serum alkaline phosphatase, the standard beta-carotene value was 81.52 units/mL, compared with 84.46 units/mL for the CCl4-treated group; however, natural algal carotenoids yielded 38.45 units/mL (D. salina) and 44.73 units/mL (Spirulina). The total albumin value diminished with CCl4 treatment (2.46 mg/mL); the effect was highest for Dunaliella, followed by the Spirulina carotenoid-treated group. The results clearly indicate that carotenoids from Dunaliella possess better hepatoprotection compared with those from Spirulina. High-performance liquid chromatography of the carotenoids indicated that Spirulina contains only beta-carotene and Dunaliella contains other carotenoids and xanthophyll. The increase in protection with Dunaliella indicates that mixed carotenoids exhibit better biological activity than beta-carotene alone. The results of this study indicate that carotenoids obtained from an algal source have a higher antihepatotoxic effect, compared with synthetic beta-carotene and with beta-carotene alone from a natural source.

  5. The effect of perioperative dexamethasone dosing on post-tonsillectomy hemorrhage risk.

    PubMed

    Yiu, Yin; Mahida, Justin B; Cooper, Jennifer N; Elsey, Nicole M; Deans, Katherine J; Minneci, Peter C; Merrill, Tyler B; Tobias, Joseph D; Elmaraghy, Charles A

    2017-07-01

    Dexamethasone is currently recommended for routine prophylaxis against postoperative nausea and vomiting after tonsillectomy procedures. However, some studies have raised concern that dexamethasone use may lead to higher rates of post-tonsillectomy hemorrhage. Our objective was to determine whether higher doses of dexamethasone administered perioperatively during tonsillectomy procedures are associated with an increased risk of secondary post-tonsillectomy hemorrhage. We conducted a retrospective review of 9843 patients who underwent tonsillectomy and received dexamethasone at our institution from January 2010 to October 2014. We compared the dose of dexamethasone administered to patients who did and did not develop secondary post-tonsillectomy hemorrhage using Mann Whitney U tests. Multivariable logistic regression models were used to evaluate the association between dexamethasone dose and post-tonsillectomy hemorrhage after adjustment for demographic and clinical characteristics. A total of 280 (2.8%) patients developed secondary post-tonsillectomy hemorrhage. Patients who developed hemorrhage tended to be older (median (interquartile range) 7 (4-11) vs. 5 (3-8) years), p < 0.001) and had undergone tonsillectomy more often for chronic tonsillitis but less often for tonsillar or adenotonsillar hypertrophy or sleep disturbances. Dexamethasone dose was significantly lower on average in patients who experienced secondary post-tonsillectomy hemorrhage (median (interquartile range) 0.19 (0.14, 0.23) mg/kg vs. 0.21 (0.17, 0.30), p < 0.001). Multivariable modeling demonstrated that the dose of dexamethasone was not significantly associated with post-tonsillectomy hemorrhage after adjustment for age. There does not appear to be a dose-related increase in the risk of post-tonsillectomy hemorrhage for patients receiving dexamethasone during tonsillectomy procedures. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Immunogenicity and safety of investigational vaccine formulations against meningococcal serogroups A, B, C, W, and Y in healthy adolescents

    PubMed Central

    Saez-Llorens, Xavier; Aguilera Vaca, Diana Catalina; Abarca, Katia; Maho, Emmanuelle; Graña, Maria Gabriela; Heijnen, Esther; Smolenov, Igor; Dull, Peter M

    2015-01-01

    This phase 2 study assessed the immunogenicity, safety, and reactogenicity of investigational formulations of meningococcal ABCWY vaccines, consisting of recombinant proteins (rMenB) and outer membrane vesicle (OMV) components of a licensed serogroup B vaccine, combined with components of a licensed quadrivalent meningococcal glycoconjugate vaccine (MenACWY-CRM). A total of 495 healthy adolescents were randomized to 6 groups to receive 2 doses (Months 0, 2) of one of 4 formulations of rMenB antigens, with or without OMV, combined with MenACWY-CRM, or 2 doses of rMenB alone or one dose of MenACWY-CRM then a placebo. Immunogenicity was assessed by serum bactericidal assay with human complement (hSBA) against serogroups ACWY and serogroup B test strains; solicited reactions and any adverse events (AEs) were assessed. Two MenABCWY vaccinations elicited robust ACWY immune responses, with higher seroresponse rates than one dose of MenACWY-CRM. Bactericidal antibody responses against the rMenB antigens and OMV components were highest in subjects who received 2 doses of OMV-containing MenABCWY formulations, with ≥68% of subjects achieving hSBA titers ≥5 against each of the serogroup B test strains. After the first dose, solicited local reaction rates were higher in the MenABCWY or rMenB groups than the MenACWY-CRM group, but similar across groups after the second dose, consisting mainly of transient injection site pain. Fever (≥38.0°C) was rare and there were no vaccine-related serious AEs. In conclusion, investigational MenABCWY formulations containing OMV components elicited highly immunogenic responses against meningococcal serogroups ACWY, as well as serogroup B test strains, with an acceptable safety profile. [NCT01210885] PMID:25969894

  7. Occupational radiation procedures and doses in South Korean dentists.

    PubMed

    Kim, Yoon-Ji; Cha, Eun Shil; Lee, Won Jin

    2016-10-01

    Dentistry is among the occupations involving chronic exposure to ionizing radiation. Although several cohort studies on medical radiation workers have been conducted in some countries, only a few epidemiological studies on dentists have been performed to examine occupational radiation exposure worldwide. The aim of this study was to investigate occupational characteristics and radiation exposures in South Korean dentists. A total of 658 dentists were surveyed from April 2012 to May 2013, and survey data were linked with dosimetry data from the National Dose Registry. Multiple linear regression analysis was used to identify the relationship between demographic or occupational factors and individual radiation doses. Of the dentists sampled, 78% were men, 51% were younger than age 40, and 61% began employment after 2000. The most frequent procedures performed by dentists were panoramic radiography, followed by intraoral and portable dental radiography. Male dentists were more frequently involved in radiation procedures, and a higher proportion of male than female dentists wore a lead apron for diagnostic radiology. The average annual effective dose was 0.18 mSv for male and 0.13 mSv for female dentists. Female dentists working in provincial areas had significantly higher average annual and cumulative effective doses than those in metropolitan areas. The cumulative effective doses were significantly greater for older dentists, those who entered the field in the 1990s, and those with longer employment duration. Our findings provided detailed information on work practices, number of procedures performed on a weekly basis, and occupational radiation doses, which enabled in-depth evaluation of occupational radiation exposure and work status among dentists. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. The effect of metoprolol and practolol on lung function and blood pressure in hypertensive asthmatics

    PubMed Central

    Formgren, H.

    1976-01-01

    1 The effect of metoprolol, a new β1-adrenoceptor blocking agent, was compared to practolol in the treatment of hypertension in seventeen asthmatics during concurrent optimum bronchodilator therapy with a selective β2-adrenoceptor-stimulant. 2 The two β-adrenoceptor antagonists were given at two dose levels, practolol (200 mg and 400 mg) daily, and metoprolol (100 mg and 200 mg) daily, in a twice-daily dosage schedule, at 12 h intervals, for 17 days. The comparison was made double-blind and a crossover design was used. The drugs were given in randomized order. The study started with a run-in placebo period and there was a washout period on placebo between the treatment periods. Spirometry, blood pressures and heart rates were recorded in a standardized manner. 3 At the lower dose levels no influence on FEV1 was noted, and no difference was found between the two active drugs. At the higher dose level FEV1 was reduced by both β-adrenoceptor-blocking drugs. Four out of twelve patients given the higher dose experienced exacerbation of their asthma. The heart rate fell with both drugs and at both dose levels. During the placebo period a marked increase of heart rate was noted. The blood pressure fell at both dose levels compared to placebo, no difference being recorded between the two drugs. 4 Metoprolol and practolol are equally effective β1-adrenoceptor blocking drugs. In this study it was found that metoprolol could be used in asthmatics who had indications for β-adrenoceptor blockade, provided that the total daily dose did not exceed 100 mg. Optimal bronchodilator treatment with a bronchoselective β-adrenoceptor agonist is an absolute prerequisite in order to avoid the risk of aggravation of asthma. PMID:22216522

  9. Inactivation of contaminated fungi and antioxidant effects of peach ( Prunus persica L. Batsch cv Dangeumdo) by 0.5-2 kGy gamma irradiation

    NASA Astrophysics Data System (ADS)

    Kim, Kyoung-Hee; Kim, Mi-Seon; Kim, Hong-Gi; Yook, Hong-Sun

    2010-04-01

    The effect of gamma irradiation (0.5-2 kGy) on the physicochemical properties of peaches was investigated during a 6-day storage at 20±3 °C. Gamma irradiation is able to inactivate the four pathogens, namely Botrytis cinerea, Penicillium expansum, Rhizopus stolonifer var. stolonifer and Monilinia fructicola in peaches. Hardness significantly decreased with the increment of irradiation dose level whereas soluble solid and total polyphenol contents increased with increment of irradiation dose level. 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical-scavenging activity of the irradiated peach was higher than that of control, and its activity increased with increment of irradiation dose level. These results suggest that gamma irradiation of peaches improved antioxidant activity, but dramatically affects the hardness throughout the entire storage time.

  10. Assessment of Intervention by a Palliative Care Team Working in a Japanese General Hospital: A Retrospective Study.

    PubMed

    Amano, Koji; Morita, Tatsuya; Tatara, Ryohei; Katayama, Hirofumi; Aiki, Sayo; Kitada, Namiki; Fumimoto, Hiromi; Sato, Emi

    2015-09-01

    Our objective was to explore the effectiveness of a palliative care team (PCT) by investigating potential differences in opioid prescription between patients who had had PCT involvement before admission to an inpatient hospice and those who had not. A total of 221 patients met the criteria; they were divided into an intervention group (n = 140) and a control group (n = 81). The daily dose of opioid before admission to the hospice was significantly higher in the intervention group (P < .001). The difference between the maximum opioid dose and the initial dose, the rate of increase in opioids until death, and the length of stay in the hospice were not significantly different between the groups. A PCT contributes to more appropriate use of opioids before admission to a hospice. © The Author(s) 2014.

  11. Population pharmacokinetics of intravenous Erwinia asparaginase in pediatric acute lymphoblastic leukemia patients.

    PubMed

    Sassen, Sebastiaan D T; Mathôt, Ron A A; Pieters, Rob; Kloos, Robin Q H; de Haas, Valérie; Kaspers, Gertjan J L; van den Bos, Cor; Tissing, Wim J E; Te Loo, Maroeska; Bierings, Marc B; Kollen, Wouter J W; Zwaan, Christian M; van der Sluis, Inge M

    2017-03-01

    Erwinia asparaginase is an important component in the treatment of pediatric acute lymphoblastic leukemia. A large variability in serum concentrations has been observed after intravenous Erwinia asparaginase. Currently, Dutch Childhood Oncology Group protocols dose alterations are based on trough concentrations to ensure adequate asparaginase activity (≥100 IU/L). The aim of this study was to describe the population pharmacokinetics of intravenous Erwinia asparaginase to quantify and gather insight into inter-individual and inter-occasion variability. The starting dose was evaluated on the basis of the derived population pharmacokinetic parameters. In a multicenter prospective observational study, a total of 714 blood samples were collected from 51 children (age 1-17 years) with acute lymphoblastic leukemia. The starting dose was 20,000 IU/m 2 three times a week and adjusted according to trough levels from week three onwards. A population pharmacokinetic model was developed using NONMEM ® A 2-compartment linear model with allometric scaling best described the data. Inter-individual and inter-occasion variability of clearance were 33% and 13%, respectively. Clearance in the first month of treatment was 14% higher ( P <0.01). Monte Carlo simulations with our pharmacokinetic model demonstrated that patients with a low weight might require higher doses to achieve similar concentrations compared to patients with high weight. The current starting dose of 20,000 IU/m 2 might result in inadequate concentrations, especially for smaller, lower weight patients, hence dose adjustments based on individual clearance are recommended. The protocols were approved by the institutional review boards. (Registered at NTR 3379 Dutch Trial Register; www.trialregister.nl). Copyright© Ferrata Storti Foundation.

  12. Diuretic effects of medetomidine compared with xylazine in healthy dogs.

    PubMed

    Talukder, Md Hasanuzzaman; Hikasa, Yoshiaki

    2009-07-01

    This study aimed to investigate and compare the effects of medetomidine and xylazine on diuretic and hormonal variables in healthy dogs. Five dogs, used in each of 11 groups, were injected intramuscularly with physiological saline solution (control), 5, 10, 20, 40, and 80 microg/kg of medetomidine, and 0.25, 0.5, 1, 2, and 4 mg/kg of xylazine. Urine and blood samples were taken 11 times over 24 h. Both medetomidine and xylazine increased urine production in a dose-dependent manner up to 4 h after injection, but the increase was much less with medetomidine than with xylazine at the tested doses. Urine specific gravity, pH, osmolality, and concentrations of creatinine, sodium, potassium, chloride, and arginine vasopressin (AVP) were decreased in a dose-dependent manner with both medetomidine and xylazine. Plasma osmolality and concentrations of sodium, potassium, and chloride were increased significantly with both drugs. Total amounts of urine AVP excreted and plasma AVP concentrations were significantly decreased by higher doses of medetomidine but were not significantly decreased by xylazine. Higher doses of both drugs significantly increased the plasma concentration of atrial natriuretic peptide (ANP), but the effect was greater with medetomidine than with xylazine. The results revealed that both drugs induce a profound diuresis, but medetomidine's effect is less dose-dependent than xylazine's effect. Although changes in plasma concentrations of AVP and ANP may partially influence the diuresis induced by medetomidine, other factors may be involved in the mechanism of the diuretic response to both drugs. Thus, both agents can be used clinically for transient but effective diuresis accompanied by sedation.

  13. Brain injury and development in preterm infants exposed to fentanyl

    PubMed Central

    McPherson, Christopher; Haslam, Matthew; Pineda, Roberta; Rogers, Cynthia; Neil, Jeffrey J.; Inder, Terrie E.

    2015-01-01

    Background Fentanyl is commonly utilized in preterm infants. Relatively little is known regarding the neurodevelopmental outcomes of preterm infants exposed to fentanyl. Objective To investigate the association between cumulative fentanyl dose and brain injury and diameters in a cohort of preterm infants Methods Data on demographics, perinatal course, and neonatal course, including total fentanyl exposure prior to term equivalent age, were retrospectively evaluated for 103 infants born at ≤ 30 weeks gestational age who underwent magnetic resonance imaging at term equivalent age (mean gestational age 26.9 ± 1.8 weeks). Magnetic resonance images were evaluated for brain injury and regional brain diameters. Developmental testing was conducted at term equivalent and 2 years of age. Results Seventy-eight infants (76%) received fentanyl (median cumulative dose 3 μg/kg, interquartile range 1 – 441 μg/kg). Cumulative fentanyl dose in the first week of life correlated with the incidence of cerebellar hemorrhage after correction for covariates (OR 2.1, 95% confidence interval 1.1 – 4.1). Cumulative fentanyl dose before term equivalent age correlated with reductions in transverse cerebellar diameter after correction for covariates including the presence of cerebellar hemorrhage (r = 0.461, p = 0.002). No correlation was detected between cumulative fentanyl dose and development at 2 years of age. Conclusions Higher cumulative fentanyl dose in preterm infants correlated with a higher incidence of cerebellar injury and lower cerebellar diameter at term equivalent age. Our findings must be taken with caution, but emphasize the need for future prospective trials examining the risks and benefits of commonly utilized analgesic agents in preterm infants. PMID:26369570

  14. Dosimetry of intracavitary placements for uterine and cervical carcinoma: results of orthogonal film, TLD, and CT-assisted techniques.

    PubMed

    Kapp, K S; Stuecklschweiger, G F; Kapp, D S; Hackl, A G

    1992-07-01

    A total of 720 192Ir high-dose-rate (HDR) applications in 331 patients with gynecological tumors were analyzed to evaluate the dose to normal tissues from brachytherapy. Based on the calculations of bladder base, bladder neck, and rectal doses derived from orthogonal films the planned tumor dose or fractionation was altered in 20.4% of intracavitary placements (ICP) for cervix carcinoma and 9.2% of ICP for treatment of the vaginal vault. In 13.8% of intracervical and 8.1% of intravaginal treatments calculated doses to both the bladder and rectum were greater than or equal to 140% of the initially planned dose fraction. Doses at the bladder base were significantly higher than at the bladder neck (p less than 0.001). In 17.5% of ICP the dose to the bladder base was at least twice as high as to the bladder neck. The ratio of bladder base dose to the bladder neck was 1.5 (+/- 1.19 SD) for intracervical and 1.46 (+/- 1.14 SD) for intravaginal applications. The comparison of calculated doses from orthogonal films with in-vivo readings showed a good correlation of rectal doses with a correlation coefficient factor of 0.9556. CT-assisted dosimetry, however, revealed that the maximum doses to bladder and rectum were generally higher than those obtained from films with ratios of 1-1.7 (average: 1.44) for the bladder neck, 1-5.4 (average: 2.42) for the bladder base, and 1.1-2.7 (average: 1.37) for the rectum. When doses to the specified reference points of bladder neck and rectum from orthogonal film dosimetry were compared with the corresponding points on CT scans, similar values were obtained for both methods with a maximum deviation of +/- 10%. Despite the determination of multiple reference points our study revealed that this information was inadequate to predict doses to the entire rectum and bladder. If conventional methods are used for dosimetry it is recommended that doses to the bladder base should be routinely calculated, since single point measurements at the bladder neck seriously underestimate the dose to the bladder. Also the rectal dose should be determined at several points over the length of the implant due to the wide range of anatomic variations possible.

  15. Pharmacokinetics, safety and tolerability of rotigotine transdermal patch in healthy Japanese and Caucasian subjects.

    PubMed

    Cawello, Willi; Kim, Seong R; Braun, Marina; Elshoff, Jan-Peer; Ikeda, Junji; Funaki, Tomoo

    2014-02-01

    Rotigotine is a dopamine receptor agonist with activity across the D1 through to D5 receptors as well as select serotonergic and adrenergic sites; continuous transdermal delivery of rotigotine with replacement of the patch once daily maintains stable plasma concentrations over 24 h. Rotigotine is indicated for the treatment of early and advanced-stage Parkinson's disease and moderate-to-severe idiopathic restless legs syndrome. The pharmacokinetics and pharmacodynamics of a drug may vary between subjects of different ethnic origin. This study evaluated the pharmacokinetics, safety, and tolerability of single-dose treatment with rotigotine transdermal patch in Japanese and Caucasian subjects. In this open-label, parallel-group study, healthy male and female subjects of Japanese or Caucasian ethnic origin were matched by sex, body mass index, and age. A single transdermal patch delivering 2 mg/24 h rotigotine (patch content 4.5 mg) was applied to the ventral/lateral abdomen for 24 h. The main outcome measures were the plasma concentrations of unconjugated and total rotigotine and its desalkyl metabolites and derived pharmacokinetic parameters (area under the concentration-time curve from time zero to last quantifiable concentration [AUClast], maximum plasma concentration [Cmax], and body weight- and dose-normalized values). The pharmacokinetic analysis included 48 subjects (24 Japanese, 24 Caucasian). The mean apparent dose of rotigotine was 2.0±0.5 mg for Japanese subjects and 2.08±0.58 mg for Caucasians. Plasma concentration-time profiles of unconjugated rotigotine and of the main metabolites were similar for both ethnic groups. Parameters of model-independent pharmacokinetics, Cmax, time to Cmax (tmax), and AUClast, for unconjugated rotigotine showed no statistically significant differences between Japanese and Caucasian subjects. Values of concentration-dependent pharmacokinetic parameters were higher in female subjects; this difference was minimized after correction for body weight. A statistically significant difference between ethnic groups was observed for total rotigotine concentrations (total rotigotine=unconjugated rotigotine+conjugated rotigotine), with slightly lower values in Caucasians after correction for body weight and apparent dose. No relevant differences were observed between males and females. Inter-individual variability was high. The terminal half-life for unconjugated rotigotine was 5.3 h in Japanese subjects and 5.7 h in Caucasians; corresponding values for total rotigotine were 8.6 h and 9.6 h. Less than 0.1% of the apparent dose was renally excreted as the parent compound. Renal elimination of total rotigotine covers 11.7% of absorbed dose in Japanese subjects and 10.8% of the absorbed dose in Caucasians, whereas the renal elimination via total despropyl rotigotine was 8.2 and 7.1%, respectively. The corresponding values for total desthienylethyl rotigotine were 3.5% in Japanese subjects and 4.2% Caucasians. Most adverse events were mild in intensity and typical for dopamine agonists or for transdermal therapeutics. Administration of a single patch delivering 2 mg/24 h rotigotine resulted in comparable pharmacokinetic profiles in Japanese and Caucasian subjects. The rotigotine transdermal patch was generally well-tolerated. Our findings suggest similar dose requirements for Japanese and Caucasian populations.

  16. Comparison of doses received by the hippocampus in patients treated with single isocenter- vs multiple isocenter-based stereotactic radiation therapy to the brain for multiple brain metastases.

    PubMed

    Algan, Ozer; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir

    2015-01-01

    To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)-based or multiple isocenter (MI)-based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V100. All of the other measured dosimetric parameters including the V95, V99, and D100 were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  17. Late-life effects on rat reproductive system after developmental exposure to mixtures of endocrine disrupters.

    PubMed

    Isling, Louise Krag; Boberg, Julie; Jacobsen, Pernille Rosenskjold; Mandrup, Karen Riiber; Axelstad, Marta; Christiansen, Sofie; Vinggaard, Anne Marie; Taxvig, Camilla; Kortenkamp, Andreas; Hass, Ulla

    2014-01-01

    This study examined late-life effects of perinatal exposure of rats to a mixture of endocrine-disrupting contaminants. Four groups of 14 time-mated Wistar rats were exposed by gavage from gestation day 7 to pup day 22 to a mixture of 13 anti-androgenic and estrogenic chemicals including phthalates, pesticides, u.v.-filters, bisphenol A, parabens, and the drug paracetamol. The groups received vehicle (control), a mixture of all 13 chemicals at 150-times (TotalMix150) or 450-times (TotalMix450) high-end human exposure, or 450-times a mixture of nine predominantly anti-androgenic chemicals (AAMix450). Onset of puberty and estrous cyclicity at 9 and 12 months of age were assessed. Few female offspring showed significantly regular estrus cyclicity at 12 months of age in the TotalMix450 and AAMix450 groups compared with controls. In 19-month-old male offspring, epididymal sperm counts were lower than controls, and in ventral prostate an overrepresentation of findings related to hyperplasia was observed in exposed groups compared with controls, particularly in the group dosed with anti-androgens. A higher incidence of pituitary adenoma at 19 months of age was found in males and females in the AAMix450 group. Developmental exposure of rats to the highest dose of a human-relevant mixture of endocrine disrupters induced adverse effects late in life, manifested as earlier female reproductive senescence, reduced sperm counts, higher score for prostate atypical hyperplasia, and higher incidence of pituitary tumors. These delayed effects highlight the need for further studies on the role of endocrine disrupters in hormone-related disorders in aging humans.

  18. A Multidose Study to Examine the Effect of Food on Evacetrapib Exposure at Steady State

    PubMed Central

    Zhang, Wei; Royalty, Jane; Cannady, Ellen A.; Downs, Delyn; Friedrich, Stuart; Suico, Jeffrey G.

    2015-01-01

    Purpose: To determine the effect of a high-fat meal on evacetrapib exposure at steady state in healthy participants. Methods: This was a randomized, 2-period, 2-sequence, open-label, crossover study. Patients were randomly assigned to 1 of the 2 treatment sequences in which they received evacetrapib 130 mg/d for 10 days following a 10-hour fast each day or following a high-fat breakfast each day. Plasma samples collected through 24 hours were analyzed for evacetrapib concentrations and pharmacokinetic parameter estimates including area under the concentration–time curve during a dosing interval (AUCτ), maximum observed concentration (Cmax), and time of Cmax (tmax) were calculated. Pharmacodynamic parameters, including cholesteryl ester transfer protein (CETP) activity, high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), total cholesterol, and triglycerides, were also assessed. Results: A total of 34 males and 6 females, mean age 41.5 years and mean body mass index 26.6 kg/m2, were enrolled. Statistical analysis showed AUCτ was 44% higher (90% confidence interval [CI]: 29%-62%) and Cmax was 51% higher (90% CI: 28%-79%) in the fed state than in the fasted state, indicating an effect of food. Consistent with higher evacetrapib exposure, changes in HDL-C, LDL-C, and CETP activity appeared to be greater in the fed state than in the fasted state. There were no notable changes in total cholesterol or triglycerides following administration in the fed and fasted states. The 130-mg doses of evacetrapib were well tolerated with and without food. Conclusion: A high-fat meal increased evacetrapib mean exposure at steady state by 44% in healthy participants. PMID:25736283

  19. Influence of hepatic impairment on the pharmacokinetics of the dopamine agonist rotigotine.

    PubMed

    Cawello, Willi; Fichtner, Andreas; Boekens, Hilmar; Braun, Marina

    2014-09-01

    The transdermally applied dopamine receptor agonist rotigotine is extensively metabolized in the liver. An open-label, parallel-group study was conducted to evaluate the effects of moderate hepatic impairment on the pharmacokinetics, safety and tolerability of rotigotine. Eight subjects with normal hepatic function and nine with moderate hepatic impairment (Child-Pugh class B) received one rotigotine transdermal patch (providing a dose of 2 mg/24 h) daily for 3 days with a 24-h patch-on period. Blood and urine samples were collected to evaluate pharmacokinetic parameters characterizing drug bioavailability and elimination. Primary variables included plasma and urine concentrations of unconjugated rotigotine (active parent compound) and total rotigotine (unconjugated rotigotine plus sulfate and glucuronide conjugates) under steady-state (SS) conditions. For unconjugated rotigotine, point estimates for the ratios of AUC(0-24)SS and C max,SS between the two groups (normal vs. impaired hepatic function) were near 1: AUC(0-24)SS, 0.90 (90 % CI 0.59, 1.38) and C max,SS, 0.94 (90 % CI 0.66, 1.35); t max,SS and t 1/2 were lower in subjects with hepatic impairment, while renal clearance was unaffected and overall clearance was higher. For total rotigotine, C max,SS was higher in subjects with hepatic impairment compared with those with normal hepatic function (P = 0.0239, ANOVA). A tendency to reduced non-renal clearance was observed in subjects with hepatic impairment, consistent with their higher plasma concentrations of total rotigotine. Thus, moderate hepatic impairment did not influence the pharmacokinetics of unconjugated rotigotine under steady-state conditions suggesting that dose adjustment will not be required for patients with mild or moderate hepatic insufficiency. In addition, the rotigotine patch was well tolerated in subjects with moderate hepatic impairment.

  20. Increasing the dose of television advertising in a national antismoking media campaign: results from a randomised field trial

    PubMed Central

    McAfee, Tim; Davis, Kevin C; Shafer, Paul; Patel, Deesha; Alexander, Robert; Bunnell, Rebecca

    2017-01-01

    Background While antismoking media campaigns have demonstrated effectiveness, less is known about the country-level effects of increased media dosing. The 2012 US Tips From Former Smokers (Tips) campaign generated approximately 1.6 million quit attempts overall; however, the specific dose–response from the campaign was only assessed by self-report. Objective Assess the impact of higher ad exposure during the 2013 Tips campaign on quit-related behaviours and intentions, campaign awareness, communication about campaign, and disease knowledge. Methods A 3-month national media buy was supplemented within 67 (of 190) randomly selected local media markets. Higher-dose markets received media buys 3 times that of standard-dose markets. We compared outcomes of interest using data collected via web-based surveys from nationally representative, address-based probability samples of 5733 cigarette smokers and 2843 non-smokers. Results In higher-dose markets, 87.2% of smokers and 83.9% of non-smokers recalled television campaign exposure versus 75.0% of smokers and 73.9% of non-smokers in standard-dose markets. Among smokers overall, the relative quit attempt rate was 11% higher in higher-dose markets (38.8% vs 34.9%; p<0.04). The higher-dose increase was larger in African-Americans (50.9% vs 31.8%; p<0.01). Smokers in higher-dose markets without a mental health condition, with a chronic health condition, or with only some college education made quit attempts at a higher rate than those in standard-dose markets. Non-smokers in higher-dose markets were more likely to talk with family or friends about smoking dangers (43.1% vs 35.7%; p<0.01) and had greater knowledge of smoking-related diseases. Conclusions The US 2013 Tips antismoking media campaign compared standard and higher doses by randomisation of local media markets. Results demonstrate the effectiveness of a higher dose for engaging non-smokers and further increasing quit attempts among smokers, especially African-Americans. PMID:26678518

  1. Total body irradiation, toward optimal individual delivery: dose evaluation with metal oxide field effect transistors, thermoluminescence detectors, and a treatment planning system.

    PubMed

    Bloemen-van Gurp, Esther J; Mijnheer, Ben J; Verschueren, Tom A M; Lambin, Philippe

    2007-11-15

    To predict the three-dimensional dose distribution of our total body irradiation technique, using a commercial treatment planning system (TPS). In vivo dosimetry, using metal oxide field effect transistors (MOSFETs) and thermoluminescence detectors (TLDs), was used to verify the calculated dose distributions. A total body computed tomography scan was performed and loaded into our TPS, and a three-dimensional-dose distribution was generated. In vivo dosimetry was performed at five locations on the patient. Entrance and exit dose values were converted to midline doses using conversion factors, previously determined with phantom measurements. The TPS-predicted dose values were compared with the MOSFET and TLD in vivo dose values. The MOSFET and TLD dose values agreed within 3.0% and the MOSFET and TPS data within 0.5%. The convolution algorithm of the TPS, which is routinely applied in the clinic, overestimated the dose in the lung region. Using a superposition algorithm reduced the calculated lung dose by approximately 3%. The dose inhomogeneity, as predicted by the TPS, can be reduced using a simple intensity-modulated radiotherapy technique. The use of a TPS to calculate the dose distributions in individual patients during total body irradiation is strongly recommended. Using a TPS gives good insight of the over- and underdosage in a patient and the influence of patient positioning on dose homogeneity. MOSFETs are suitable for in vivo dosimetry purposes during total body irradiation, when using appropriate conversion factors. The MOSFET, TLD, and TPS results agreed within acceptable margins.

  2. Physical activity and risk of breast cancer, colon cancer, diabetes, ischemic heart disease, and ischemic stroke events: systematic review and dose-response meta-analysis for the Global Burden of Disease Study 2013.

    PubMed

    Kyu, Hmwe H; Bachman, Victoria F; Alexander, Lily T; Mumford, John Everett; Afshin, Ashkan; Estep, Kara; Veerman, J Lennert; Delwiche, Kristen; Iannarone, Marissa L; Moyer, Madeline L; Cercy, Kelly; Vos, Theo; Murray, Christopher J L; Forouzanfar, Mohammad H

    2016-08-09

     To quantify the dose-response associations between total physical activity and risk of breast cancer, colon cancer, diabetes, ischemic heart disease, and ischemic stroke events.  Systematic review and Bayesian dose-response meta-analysis.  PubMed and Embase from 1980 to 27 February 2016, and references from relevant systematic reviews. Data from the Study on Global AGEing and Adult Health conducted in China, Ghana, India, Mexico, Russia, and South Africa from 2007 to 2010 and the US National Health and Nutrition Examination Surveys from 1999 to 2011 were used to map domain specific physical activity (reported in included studies) to total activity.  Prospective cohort studies examining the associations between physical activity (any domain) and at least one of the five diseases studied.  174 articles were identified: 35 for breast cancer, 19 for colon cancer, 55 for diabetes, 43 for ischemic heart disease, and 26 for ischemic stroke (some articles included multiple outcomes). Although higher levels of total physical activity were significantly associated with lower risk for all outcomes, major gains occurred at lower levels of activity (up to 3000-4000 metabolic equivalent (MET) minutes/week). For example, individuals with a total activity level of 600 MET minutes/week (the minimum recommended level) had a 2% lower risk of diabetes compared with those reporting no physical activity. An increase from 600 to 3600 MET minutes/week reduced the risk by an additional 19%. The same amount of increase yielded much smaller returns at higher levels of activity: an increase of total activity from 9000 to 12 000 MET minutes/week reduced the risk of diabetes by only 0.6%. Compared with insufficiently active individuals (total activity <600 MET minutes/week), the risk reduction for those in the highly active category (≥8000 MET minutes/week) was 14% (relative risk 0.863, 95% uncertainty interval 0.829 to 0.900) for breast cancer; 21% (0.789, 0.735 to 0.850) for colon cancer; 28% (0.722, 0.678 to 0.768) for diabetes; 25% (0.754, 0.704 to 0.809) for ischemic heart disease; and 26% (0.736, 0.659 to 0.811) for ischemic stroke.  People who achieve total physical activity levels several times higher than the current recommended minimum level have a significant reduction in the risk of the five diseases studied. More studies with detailed quantification of total physical activity will help to find more precise relative risk estimates for different levels of activity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Healthcare resource use and cost associated with varying dosages of extended corticosteroid exposure in a US population.

    PubMed

    Rice, J Bradford; White, Alan G; Johnson, Michaela; Wagh, Aneesha; Qin, Yimin; Bartels-Peculis, Laura; Ciepielewska, Gosia; Nelson, Winnie W

    2018-05-23

    To quantify healthcare resource use (HCRU) and costs associated with varying levels of corticosteroid exposure. Patients with a diagnosis of selected autoimmune and inflammatory diseases between 1 January 2006 and 30 September 2015 ("study period") were selected from a de-identified, privately-insured claims database. Patients were stratified into four treatment cohorts based on the dosing and duration of continuous corticosteroid use following disease diagnosis: intermittent use with <60 days of corticosteroid use and ≥60 days of corticosteroid use with low (≤7.5 mg/day), medium (>7.5-≤15 mg/day), or high (>15 mg/day) dosage. Patients were followed from the date of their highest dose episode of corticosteroid use ("treatment index date") until the earliest of the end of continuous corticosteroid use +30 days, disenrollment from health plan, or the end of the study period ("follow-up period"). HCRU and costs in the follow-up period were compared across treatment cohorts. Of 78,704 patients who were identified for study inclusion, 29% had extended corticosteroid use lasting ≥60 days, and 71% had intermittent use. On average, patients in the high-dose cohort incurred twice the cost of intermittent users ($68,408 vs $32,690 in annualized total all-cause healthcare costs, USD). Adverse event-related medical costs accounted for ∼40% of medical costs, and were higher than disease-related medical costs for all cohorts with extended corticosteroid exposure. Comparing the high-dose and low-dose cohorts, the smaller savings in disease-related prescriptions ($1,680) occurred along with a much larger cost in adverse event-related spend ($13,464). The impact of corticosteroids may be under-estimated because of conservative follow-up duration, and administrative data may contain inaccuracies in coding. Steroid use, especially at higher doses, is associated with higher HCRU and costs.

  4. A search for new CYP3A4 variants as determinants of tacrolimus dose requirements in renal-transplanted patients.

    PubMed

    Tavira, Beatriz; Coto, Eliecer; Diaz-Corte, Carmen; Alvarez, Victoria; López-Larrea, Carlos; Ortega, Francisco

    2013-08-01

    The CYP3A5*3 and CYP3A4*1B alleles have been related with tacrolimus (Tac) dose requirements. The rare CYP3A4*22 variant has also been associated with a significantly lower Tac dose. We genotyped the three single-nucleotide polymorphisms in 206 kidney-transplanted patients who received Tac as the primary immunosuppressor. CYP3A5*1 and CYP3A4*1B allele carriers received a significantly higher Tac dose (P<0.01) compared with wild-type homozygotes. We did not find significant differences between the CYP3A4*22 genotypes, either nominally or according to the CYP3A5 genotype (expressers vs. nonexpressers). Sequencing of CYP3A4 coding exons in a total of 15 patients revealed only one nonreported missense change (p.P227>T) in one patient. We concluded that CYP3A5*3 and CYP3A4*1B were the main determinants of the Tac dose-adjusted blood concentration in our cohort of renal-transplanted patients.

  5. Metabolic and pharmacokinetic studies of scutellarin in rat plasma, urine, and feces.

    PubMed

    Xing, Jian-feng; You, Hai-sheng; Dong, Ya-lin; Lu, Jun; Chen, Si-ying; Zhu, Hui-fang; Dong, Qian; Wang, Mao-yi; Dong, Wei-hua

    2011-05-01

    To study the metabolic and pharmacokinetic profile of scutellarin, an active component from the medical plant Erigeron breviscapus (Vant) Hand-Mazz, and to investigate the mechanisms underlying the low bioavailability of scutellarin though oral or intravenous administration in rats. HPLC method was developed for simultaneous detection of scutellarin and scutellarein (the aglycone of scutellarin) in rat plasma, urine and feces. The in vitro metabolic stability study was carried out in rat liver microsomes from different genders. After a single oral dose of scutellarin (400 mg/kg), the plasma concentrations of scutellarin and scutellarein in female rats were significantly higher than in male ones. Between the female and male rats, significant differences in AUC, t(max2) and C(max2) for scutellarin were found. The pharmacokinetic parameters of scutellarin in the urine also showed significant gender differences. After a single oral dose of scutellarin (400 mg/kg), the total percentage excretion of scutellarein in male and female rats was 16.5% and 8.61%, respectively. The total percentage excretion of scutellarin and scutellarein in the feces was higher with oral administration than with intravenous administration. The in vitro t(1/2) and CL(int) value for scutellarin in male rats was significantly higher than that in female rats. The results suggest that a large amount of ingested scutellarin was metabolized into scutellarein in the gastrointestinal tract and then excreted with the feces, leading to the extremely low oral bioavailability of scutellarin. The gender differences of pharmacokinetic parameters of scutellarin and scutellarein are due to the higher CL(int) and lower absorption in male rats.

  6. Metabolic and pharmacokinetic studies of scutellarin in rat plasma, urine, and feces

    PubMed Central

    Xing, Jian-feng; You, Hai-sheng; Dong, Ya-lin; Lu, Jun; Chen, Si-ying; Zhu, Hui-fang; Dong, Qian; Wang, Mao-yi; Dong, Wei-hua

    2011-01-01

    Aim: To study the metabolic and pharmacokinetic profile of scutellarin, an active component from the medical plant Erigeron breviscapus (Vant) Hand-Mazz, and to investigate the mechanisms underlying the low bioavailability of scutellarin though oral or intravenous administration in rats. Methods: HPLC method was developed for simultaneous detection of scutellarin and scutellarein (the aglycone of scutellarin) in rat plasma, urine and feces. The in vitro metabolic stability study was carried out in rat liver microsomes from different genders. Results: After a single oral dose of scutellarin (400 mg/kg), the plasma concentrations of scutellarin and scutellarein in female rats were significantly higher than in male ones. Between the female and male rats, significant differences in AUC, tmax2 and Cmax2 for scutellarin were found. The pharmacokinetic parameters of scutellarin in the urine also showed significant gender differences. After a single oral dose of scutellarin (400 mg/kg), the total percentage excretion of scutellarein in male and female rats was 16.5% and 8.61%, respectively. The total percentage excretion of scutellarin and scutellarein in the feces was higher with oral administration than with intravenous administration. The in vitro t1/2 and CLint value for scutellarin in male rats was significantly higher than that in female rats. Conclusion: The results suggest that a large amount of ingested scutellarin was metabolized into scutellarein in the gastrointestinal tract and then excreted with the feces, leading to the extremely low oral bioavailability of scutellarin. The gender differences of pharmacokinetic parameters of scutellarin and scutellarein are due to the higher CLint and lower absorption in male rats. PMID:21516133

  7. Dedicated high dose rate 192Ir brachytherapy radiation fields for in vitro cell exposures at variable source-target cell distances: killing of mammalian cells depends on temporal dose rate fluctuation

    NASA Astrophysics Data System (ADS)

    Veigel, Cornelia; Hartmann, Günther H.; Fritz, Peter; Debus, Jürgen; Weber, Klaus-Josef

    2017-02-01

    Afterloading brachytherapy is conducted by the stepwise movement of a radioactive source through surgically implanted applicator tubes where at predefined dwell positions calculated dwell times optimize spatial dose delivery with respect to a planned dose level. The temporal exposure pattern exhibits drastic fluctuations in dose rate at a given coordinate and within a single treatment session because of the discontinuous and repeated source movement into the target volume. This could potentially affect biological response. Therefore, mammalian cells were exposed as monolayers to a high dose rate 192Ir source by utilizing a dedicated irradiation device where the distance between a planar array of radioactive source positions and the plane of the cell monolayer could be varied from 2.5 mm to 40 mm, thus varying dose rate pattern for any chosen total dose. The Gammamed IIi afterloading system equipped with a nominal 370 GBq (10 Ci) 192-Ir source was used to irradiate V79 Chinese hamster lung fibroblasts from both confluent and from exponential growth phase with dose up to 12 Gy (at room temperature, total exposure not exceeding 1 h). For comparison, V79 cells were also exposed to 6 MV x-rays from a clinical linear accelerator (dose rate of 2.5 Gy min-1). As biological endpoint, cell survival was determined by standard colony forming assay. Dose measurements were conducted with a diamond detector (sensitive area 7.3 mm2), calibrated by means of 60Co radiation. Additionally, dose delivery was simulated by Monte Carlo calculations using the EGSnrc code system. The calculated secondary electron fluence spectra at the cell location did not indicate a significant change of radiation quality (i.e. higher linear energy transfer) at the lower distances. Clonogenic cell survival curves obtained after brachytherapy exhibited an altered biological response compared to x-rays which was characterized by a significant reduction of the survival curve shoulder when dose rate fluctuations were high. Therefore, also for the time scale of the present investigation, cellular effects of radiation are not invariant to the temporal pattern in dose rate. We propose that with high dose rate variation the cells activate less efficiently their DNA damage response than after continuous irradiation.

  8. Older patients with chronic myeloid leukemia (≥65 years) profit more from higher imatinib doses than younger patients: a subanalysis of the randomized CML-Study IV.

    PubMed

    Proetel, Ulrike; Pletsch, Nadine; Lauseker, Michael; Müller, Martin C; Hanfstein, Benjamin; Krause, Stefan W; Kalmanti, Lida; Schreiber, Annette; Heim, Dominik; Baerlocher, Gabriela M; Hofmann, Wolf-Karsten; Lange, Elisabeth; Einsele, Hermann; Wernli, Martin; Kremers, Stephan; Schlag, Rudolf; Müller, Lothar; Hänel, Mathias; Link, Hartmut; Hertenstein, Bernd; Pfirrman, Markus; Hochhaus, Andreas; Hasford, Joerg; Hehlmann, Rüdiger; Saußele, Susanne

    2014-07-01

    The impact of imatinib dose on response rates and survival in older patients with chronic myeloid leukemia in chronic phase has not been studied well. We analyzed data from the German CML-Study IV, a randomized five-arm treatment optimization study in newly diagnosed BCR-ABL-positive chronic myeloid leukemia in chronic phase. Patients randomized to imatinib 400 mg/day (IM400) or imatinib 800 mg/day (IM800) and stratified according to age (≥65 years vs. <65 years) were compared regarding dose, response, adverse events, rates of progression, and survival. The full 800 mg dose was given after a 6-week run-in period with imatinib 400 mg/day. The dose could then be reduced according to tolerability. A total of 828 patients were randomized to IM400 or IM800. Seven hundred eighty-four patients were evaluable (IM400, 382; IM800, 402). One hundred ten patients (29 %) on IM400 and 83 (21 %) on IM800 were ≥65 years. The median dose per day was lower for patients ≥65 years on IM800, with the highest median dose in the first year (466 mg/day for patients ≥65 years vs. 630 mg/day for patients <65 years). Older patients on IM800 achieved major molecular remission and deep molecular remission as fast as younger patients, in contrast to standard dose imatinib with which older patients achieved remissions much later than younger patients. Grades 3 and 4 adverse events were similar in both age groups. Five-year relative survival for older patients was comparable to that of younger patients. We suggest that the optimal dose for older patients is higher than 400 mg/day. ClinicalTrials.gov identifier: NCT00055874

  9. Radiation-induced second cancers: the impact of 3D-CRT and IMRT

    NASA Technical Reports Server (NTRS)

    Hall, Eric J.; Wuu, Cheng-Shie

    2003-01-01

    Information concerning radiation-induced malignancies comes from the A-bomb survivors and from medically exposed individuals, including second cancers in radiation therapy patients. The A-bomb survivors show an excess incidence of carcinomas in tissues such as the gastrointestinal tract, breast, thyroid, and bladder, which is linear with dose up to about 2.5 Sv. There is great uncertainty concerning the dose-response relationship for radiation-induced carcinogenesis at higher doses. Some animal and human data suggest a decrease at higher doses, usually attributed to cell killing; other data suggest a plateau in dose. Radiotherapy patients also show an excess incidence of carcinomas, often in sites remote from the treatment fields; in addition there is an excess incidence of sarcomas in the heavily irradiated in-field tissues. The transition from conventional radiotherapy to three-dimensional conformal radiation therapy (3D-CRT) involves a reduction in the volume of normal tissues receiving a high dose, with an increase in dose to the target volume that includes the tumor and a limited amount of normal tissue. One might expect a decrease in the number of sarcomas induced and also (less certain) a small decrease in the number of carcinomas. All around, a good thing. By contrast, the move from 3D-CRT to intensity-modulated radiation therapy (IMRT) involves more fields, and the dose-volume histograms show that, as a consequence, a larger volume of normal tissue is exposed to lower doses. In addition, the number of monitor units is increased by a factor of 2 to 3, increasing the total body exposure, due to leakage radiation. Both factors will tend to increase the risk of second cancers. Altogether, IMRT is likely to almost double the incidence of second malignancies compared with conventional radiotherapy from about 1% to 1.75% for patients surviving 10 years. The numbers may be larger for longer survival (or for younger patients), but the ratio should remain the same.

  10. Total Dose Survivability of Hubble Electronic Components

    NASA Technical Reports Server (NTRS)

    Xapsos, M. A.; Stauffer, C.; Jordan, T.; Poivey, C.; Haskins, D. N.; Lum, G.; Pergosky, A. M.; Smith, D. C.; LaBel, K. A.

    2017-01-01

    A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.

  11. New Approach to Total Dose Specification for Spacecraft Electronics

    NASA Technical Reports Server (NTRS)

    Xapsos, Michael

    2017-01-01

    Variability of the space radiation environment is investigated with regard to total dose specification for spacecraft electronics. It is shown to have a significant impact. A new approach is developed for total dose requirements that replaces the radiation design margin concept with failure probability during a mission.

  12. LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

    NASA Technical Reports Server (NTRS)

    Oldham, Timothy; Pellish, Jonathan; Boutte, Alvin

    2012-01-01

    This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

  13. Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization

    NASA Astrophysics Data System (ADS)

    Gong, Changfei; Han, Ce; Gan, Guanghui; Deng, Zhenxiang; Zhou, Yongqiang; Yi, Jinling; Zheng, Xiaomin; Xie, Congying; Jin, Xiance

    2017-04-01

    Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as ‘PWLS-ndiSTV’. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.

  14. The effect of age on the pharmacological management of ambulatory patients treated with depot neuroleptic medications for schizophrenia and related psychotic disorders.

    PubMed

    Mamo, David C; Sweet, Robert A; Chengappa, K N Roy; Reddy, Ravinder R; Jeste, Dilip V

    2002-11-01

    Cross-sectional studies indicate that, in comparison to younger patients, older schizophrenic patients have a higher risk for neuroleptic-induced Parkinsonism and tardive dyskinesia (TD). It has been suggested, therefore, that older patients with schizophrenia could be maintained on reduced doses of conventional neuroleptics. We examined the effect of age on psychopharmacological management in a naturalistic study of a group of 165 patients with a clinical diagnosis of schizophrenia or a related psychotic disorder (age range = 21-84 years; subjects > or = 1;45 years n = 86) treated with either haloperidol decanoate or fluphenazine decanoate. Increasing age was not correlated with total daily dose of neuroleptics or anticholinergic medication. However, a modest negative correlation of age with daily neuroleptic dose was found in patients aged 45 years and older. The results of this study highlight the need for prospective assessments of depot neuroleptic dose requirements in older patients suffering from primary psychotic disorders. Copyright 2002 John Wiley & Sons, Ltd.

  15. X-ray photoelectron and mass spectroscopic study of electron irradiation and thermal stability of polytetrafluoroethylene

    NASA Technical Reports Server (NTRS)

    Wheeler, Donald R.; Pepper, Stephen V.

    1990-01-01

    Polytetrafluoroethylene (PTFE) was subjected to 3 keV electron bombardment and then heated in vacuum to 300 C. The behavior of the material as a function of radiation dose and temperature was studied by X-ray photoelectron spectroscopy (XPS) of the surface and mass spectroscopy of the species evolved. A quantitative comparison of the radiation dose rate with that in other reported studies showed that, for a given total dose, the damage observed by XPS is greater for higher dose rates. Lightly damaged material heated to 300 C evolved saturated fluorocarbon species, whereas unsaturated fluorocarbon species evolved from heavily damaged material. After heating the heavily damaged material, those features in the XPS that were associated with damage diminished, giving the appearance that the radiation damage annealed. The apparent annealing of the radiation damage was found to be due to the covering of the network by saturated fragments that easily diffused through the decomposed material to the surface region upon heating.

  16. Effect of gamma irradiation on lipoxygenases, trypsin inhibitor, raffinose family oligosaccharides and nutritional factors of different seed coat colored soybean (Glycine max L.)

    NASA Astrophysics Data System (ADS)

    Kumar Dixit, Amit; Kumar, Vineet; Rani, Anita; Manjaya, J. G.; Bhatnagar, Deepak

    2011-04-01

    Three soybean genotypes Kalitur, Hara soya and NRC37 with black, green and yellow seed coat color, respectively, were gamma irradiated at 0.5, 2.0 and 5.0 kGy and tested for antinutritional and nutritional factors. Gamma irradiation at all doses reduced the level of lipoxygenase isomers, trypsin inhibitor (TI) and ascorbic acid in all the 3 soybean genotypes as compared to the unirradiated control. However, irradiation dose of 5.0 kGy increased the sucrose content of the soybean genotypes. No significant change was observed in oil, protein fatty acids and total tocopherol content of the 3 genotypes at any irradiation dose. It is suggested that inhibition of lipoxygenase, reduction in TI and ascorbic acid may be due to the breakage or oxidation of protein structure by the gamma irradiation. Similarly, gamma irradiation at higher doses may break glycosidic linkages in oligosaccharides to produce more sucrose and decrease the content of flatulence causing oligosaccharides.

  17. Effects of gamma irradiation on physicochemical properties, antioxidant and microbial activities of sour cherry juice

    NASA Astrophysics Data System (ADS)

    Arjeh, Edris; Barzegar, Mohsen; Ali Sahari, Mohammad

    2015-09-01

    Recently, due to the beneficial effects of bioactive compounds, demand for minimally processed fruits and fruit juices has increased rapidly in the world. In this study, sour cherry juice (SCJ) was exposed to gamma irradiation at 0.0, 0.5, 1.5, 3.0, 4.5, and 6.0 kGy and then stored at 4 °C for 60 days. Total soluble solids (TSS), total acidity (TA), color, total phenolic content (TPC), total monomeric anthocyanin content (TMC), antioxidant activity, organic acid profile, and microbial analysis were evaluated at regular intervals during the storage. Results indicated that irradiation did not have any significant effect on TSS, while level of TA increased significantly at the dose of 6 kGy (p<0.05). Furthermore, irradiation treatment and storage time led to a significant increase in L* and b* values and a decrease in a* values. Total monomeric anthocyanin content of the irradiated SCJ was lower than that of the non-irradiated one (24% at 3.0 kGy) and also changed toward a more negative direction during the storage (63% at 3.0 kGy for 60 days). There was a significant decrease in the antioxidant activity (DPPH radical scavenging and FRAP assay) in both irradiated and stored SCJs. After irradiation (0-6 kGy), the results showed that the concentration of malic and oxalic acid significantly increased; but, the concentration of ascorbic, citric, fumaric, and succinic acids significantly decreased. Gamma irradiation with doses of ≥3 kGy resulted in overall reduction in microbial loads. Based on the results obtained from the changes of physicochemical properties, antioxidant activity, and microbial analysis, irradiation of SCJ at doses of higher than 3.0 kGy is not recommended.

  18. Total dose bias dependency and ELDRS effects in bipolar linear devices

    NASA Technical Reports Server (NTRS)

    Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.

    2002-01-01

    Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

  19. Pupillometry as an indicator of L-DOPA dosages in Parkinson's disease patients.

    PubMed

    Bartošová, O; Bonnet, C; Ulmanová, O; Šíma, M; Perlík, F; Růžička, E; Slanař, O

    2018-04-01

    Dopamine was shown to induce mydriasis by excitation of alpha-adrenergic receptors at the dilator pupillae muscle. Pupilla diameter may thus serve as an indirect measure of peripheral pharmacokinetics of L-DOPA and dopamine. The aim of this study is to evaluate the effect of L-DOPA dosage on pupillometric parameters in Parkinson's disease (PD) patients. Sixteen PD patients and 14 healthy control subjects (CS) were studied. The statistical analysis revealed significant differences between CS and PD patients for the mean maximum and minimum pupil diameters (p = 0.017, p = 0.028, respectively), with higher values found in PD. Moreover, a significant dose-response relationship was found between the maximum pupil diameter and both the morning L-DOPA dose (R 2  = 0.78) and the total daily L-DOPA dose (R 2  = 0.93). A sigmoid-shaped curve best describes the dose-response relationship, with a ceiling effect at about 400 mg L-DOPA daily dose. In conclusion, measuring pupillometric parameters represents a sensitive tool for non-invasive evaluation of the peripheral effect of L-DOPA, especially with daily doses below 400 mg L-DOPA.

  20. Assessment of radiation doses from residential smoke detectors that contain americium-241

    NASA Astrophysics Data System (ADS)

    Odonnell, F. R.; Etnier, E. L.; Holton, G. A.; Travis, C. C.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv to 20 nSv for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 micro-Sv (0.0006 to 8 mrem) to total body and from 0.06 to 800 micro-Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft squared.

  1. Therapeutic use of fractionated total body and subtotal body irradiation. [X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loeffler, R.K.

    1981-05-01

    Ninety-one patients were treated using fractionated subtotal body (STBI) or total body irradiation (TBI). These patients had generalized lymphomas, Hodgkin's disease, leukemias, myelomas, seminomas, or oat-cell carcinomas. Subtotal body irradiation is delivered to the entire body, except for the skull and extremities. It was expected that a significantly higher radiation dose could be administered with STBI than with TBI. A five- to ten-fold increase in tolerance for STBI was demonstrated. Many of these patients have had long-term emissions. There is little or no treatment-induced symptomatology, and no sanctuary sites.

  2. Optical fibres in the radiation environment of CERN

    NASA Astrophysics Data System (ADS)

    Guillermain, E.

    2017-11-01

    CERN, the European Organization for Nuclear Research (in Geneva, Switzerland), is home to a complex scientific instrument: the 27-kilometre Large Hadron Collider (LHC) collides beams of high-energy particles at close to the speed of light. Optical fibres are widely used at CERN, both in surface areas (e.g. for inter-building IT networks) and in the accelerator complex underground (e.g. for cryogenics, vacuum, safety systems). Optical fibres in the accelerator are exposed to mixed radiation fields (mainly composed of protons, pions, neutrons and other hadrons, gamma rays and electrons), with dose rates depending on the particular installation zone, and with radiation levels often significantly higher than those encountered in space. In the LHC and its injector chain radiation levels range from relatively low annual doses of a few Gy up to hundreds of kGy. Optical fibres suffer from Radiation Induced Attenuation (RIA, expressed in dB per unit length) that affect light transmission and which depends on the irradiation conditions (e.g. dose rate, total dose, temperature). In the CERN accelerator complex, the failure of an optical link can affect the proper functionality of control or monitoring systems and induce the interruption of the accelerator operation. The qualification of optical fibres for installation in critical radiation areas is therefore crucial. Thus, all optical fibre types installed in radiation areas at CERN are subject to laboratory irradiation tests, in order to evaluate their RIA at different total dose and dose rates. This allows the selection of the appropriate optical fibre type (conventional or radiation resistant) compliant with the requirements of each installation. Irradiation tests are performed in collaboration with Fraunhofer INT (irradiation facilities and expert team in Euskirchen, Germany). Conventional off-the-shelf optical fibres can be installed for optical links exposed to low radiation levels (i.e. annual dose typically below few kGy). Nevertheless, the conventional optical fibres must be carefully qualified as a spread in RIA of factor 10 is observed among optical fibres of different types and dopants. In higher radiation areas, special radiation resistant optical fibres are installed. For total dose above 1 kGy, the RIA of these special optical fibres is at least 10 times lower than the conventional optical fibres RIA at same irradiation conditions. 2400 km of these special radiation resistant optical fibres were recently procured at CERN. As part of this procurement process, a quality assurance plan including the irradiation testing of all 65 produced batches was set up. This presentation will review the selection process of the appropriate optical fibre types to be installed in the radiation environment of CERN. The methodology for choosing the irradiation parameters for the laboratory tests will be discussed together with an overview of the RIA of different optical fibre types under several irradiation conditions.

  3. Nonadministration of medication doses for venous thromboembolism prophylaxis in a cohort of hospitalized patients.

    PubMed

    Popoola, Victor O; Lau, Brandyn D; Tan, Esther; Shaffer, Dauryne L; Kraus, Peggy S; Farrow, Norma E; Hobson, Deborah B; Aboagye, Jonathan K; Streiff, Michael B; Haut, Elliott R

    2018-03-15

    Results of a study to characterize patterns of nonadministration of medication doses for venous thromboembolism (VTE) prevention among hospitalized patients are presented. The electronic records of all patients admitted to 4 floors of a medical center during a 1-month period were examined to identify patients whose records indicated at least 1 nonadministered dose of medication for VTE prophylaxis. Proportions of nonadministered doses by medication type, intended route of administration, and VTE risk categorization were compared; reasons for nonadministration were evaluated. Overall, 12.7% of all medication doses prescribed to patients in the study cohort ( n = 75) during the study period (857 of 6,758 doses in total) were not administered. Nonadministration of 1 or more doses of VTE prophylaxis medication was nearly twice as likely for subcutaneous anticoagulants than for all other medication types (231 of 1,112 doses [20.8%] versus 626 of 5,646 doses [11.2%], p < 0.001). For all medications prescribed, the most common reason for nonadministration was patient refusal (559 of 857 doses [65.2%]); the refusal rate was higher for subcutaneous anticoagulants than for all other medication categories (82.7% versus 58.8%, p < 0.001). Doses of antiretrovirals, immunosuppressives, antihypertensives, psychiatric medications, analgesics, and antiepileptics were less commonly missed than doses of electrolytes, vitamins, and gastrointestinal medications. Scheduled doses of subcutaneous anticoagulants for hospitalized patients were more likely to be missed than doses of all other medication types. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  4. Can Saliva and Plasma Methadone Concentrations Be Used for Enantioselective Pharmacokinetic and Pharmacodynamic Studies in Patients With Advanced Cancer?

    PubMed

    George, Rani; Haywood, Alison; Good, Phillip; Hennig, Stefanie; Khan, Sohil; Norris, Ross; Hardy, Janet

    2017-09-01

    Methadone is a potent analgesic used to treat refractory cancer pain. It is administered as a racemic mixture, with the l-enantiomer being primarily a μ-receptor agonist, whereas the d-enantiomer is an N-methyl-d-aspartate antagonist and inhibits serotonin and norepinephrine reuptake. Dose requirements vary greatly among patients to achieve optimal pain control and to avoid the risk of adverse effects. The relationship between plasma and saliva methadone enantiomer concentrations was investigated to determine if saliva could be a substitute for plasma in pharmacodynamic and pharmacokinetic studies for clinical monitoring and dose optimization of methadone in patients with advanced cancer. Patients with advanced cancer who were prescribed varying doses of oral methadone for pain management were recruited to obtain paired plasma and saliva samples. Pain scores were recorded at the time of sampling. The total and unbound plasma and saliva concentrations of the l- and d-enantiomers of methadone were quantified by using an HPLC-MS/MS method. The relationship between plasma (total and unbound) and saliva concentrations were compared. The saliva-to-plasma concentration ratio was compared versus the dose administered and the time after dosing for both enantiomers. The association of methadone concentrations with reported pain scores was compared by using a Mann-Whitney U test for significance. Fifty patients receiving a mean dose of 11mg/d of methadone provided 151 paired plasma and saliva samples. The median age of the population was 61 years with an interquartile range of 53-71 years with total body weight ranging from 59-88 kg. Median (interquartile) total plasma concentrations for l- and d-methadone were 50.78 ng/mL (30.6-113.0 ng/mL) and 62.0 ng/mL (28.7-116.0 ng/mL), respectively. Median (interquartile range) saliva concentrations for l- and d-methadone were 81.5 ng/mL (28.0-203.2 ng/mL) and 44.2 (16.2-149.7 ng/mL). No relationship could be established between plasma and saliva concentrations for l- and d-methadone (r 2 = 0.35 and 0.25). The saliva-to-plasma concentration analyzed with the methadone dose showed higher saliva concentrations at lower doses. Dose-normalized saliva concentrations followed a similar pattern over time compared with plasma concentrations. No correlation was found between l-methadone plasma, d-methadone plasma, l-methadone saliva, d-methadone saliva concentrations, and pain score. Saliva concentration was not a better predictor of pain control than plasma concentration for dose optimization and monitoring studies of methadone in patients with cancer. Although the saliva-to-plasma ratio of the concentration of methadone enantiomers was stable across the dosing range, due to the variability in individual saliva-to-plasma ratios, saliva sampling may not be a valid substitute in pharmacokinetic studies of methadone in cancer. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  5. Increasing the dose of television advertising in a national antismoking media campaign: results from a randomised field trial.

    PubMed

    McAfee, Tim; Davis, Kevin C; Shafer, Paul; Patel, Deesha; Alexander, Robert; Bunnell, Rebecca

    2017-01-01

    While antismoking media campaigns have demonstrated effectiveness, less is known about the country-level effects of increased media dosing. The 2012 US Tips From Former Smokers (Tips) campaign generated approximately 1.6 million quit attempts overall; however, the specific dose-response from the campaign was only assessed by self-report. Assess the impact of higher ad exposure during the 2013 Tips campaign on quit-related behaviours and intentions, campaign awareness, communication about campaign, and disease knowledge. A 3-month national media buy was supplemented within 67 (of 190) randomly selected local media markets. Higher-dose markets received media buys 3 times that of standard-dose markets. We compared outcomes of interest using data collected via web-based surveys from nationally representative, address-based probability samples of 5733 cigarette smokers and 2843 non-smokers. In higher-dose markets, 87.2% of smokers and 83.9% of non-smokers recalled television campaign exposure versus 75.0% of smokers and 73.9% of non-smokers in standard-dose markets. Among smokers overall, the relative quit attempt rate was 11% higher in higher-dose markets (38.8% vs 34.9%; p<0.04). The higher-dose increase was larger in African-Americans (50.9% vs 31.8%; p<0.01). Smokers in higher-dose markets without a mental health condition, with a chronic health condition, or with only some college education made quit attempts at a higher rate than those in standard-dose markets. Non-smokers in higher-dose markets were more likely to talk with family or friends about smoking dangers (43.1% vs 35.7%; p<0.01) and had greater knowledge of smoking-related diseases. The US 2013 Tips antismoking media campaign compared standard and higher doses by randomisation of local media markets. Results demonstrate the effectiveness of a higher dose for engaging non-smokers and further increasing quit attempts among smokers, especially African-Americans. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Body mass index standard deviation score and obesity in children with type 1 diabetes in the Nordic countries. HbA1c and other predictors of increasing BMISDS.

    PubMed

    Birkebaek, N H; Kahlert, J; Bjarnason, R; Drivvoll, A K; Johansen, A; Konradsdottir, E; Pundziute-Lyckå, A; Samuelsson, U; Skrivarhaug, T; Svensson, J

    2018-05-21

    Intensified insulin therapy may increase body weight and cause obesity. This study compared body mass index standard deviation score (BMISDS) and obesity rate in children with type 1 diabetes (T1D) in Denmark, Iceland, Norway and Sweden, and uncovered predictors for increasing BMISDS. Data registered in the Nordic national childhood diabetes databases during the period 2008-2012 on children below 15 years with T1D for more than 3 months were compiled, including information on gender, age, diabetes duration, hemoglobin A 1c (HbA 1c ), insulin dose, severe hypoglycemia (SH), treatment modality, height and weight. The Swedish reference chart for BMI was used for calculating BMISDS. Totally, 11 025 children (48% females) (30 994 registrations) were included. Medians by the last recorded examination were: age, 13.5 years; diabetes duration, 4.3 years; HbA 1c , 7.9% (63 mmol/mol); insulin dose, 0.8 IU/kg/d and BMISDS, 0.70. Obesity rate was 18.5%. Adjusted mean BMISDS (BMISDS adj) was inversely related to HbA 1c and directly to diabetes duration. Higher BMISDS adj was found in those with an insulin dose above 0.6 IU/kg/d, and in girls above 10 years. Pump users had higher BMISDS adj than pen users, and patients with registered SH had higher BMISDS adj than patients without SH (both P < .001). Obesity rate in children with T1D in the Nordic countries is high, however, with country differences. Low HbA 1c , long diabetes duration, higher insulin dose, pump treatment and experiencing a SH predicted higher BMISDS. Diabetes caregivers should balance the risk of obesity and the benefit of a very low HbA 1c. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Jeffrey M.; Handorf, Elizabeth A.; Price, Robert A.

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 receivedmore » a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.« less

  8. Evaluation of 16 genotype-guided Warfarin Dosing Algorithms in 310 Korean Patients Receiving Warfarin Treatment: Poor Prediction Performance in VKORC1 1173C Carriers.

    PubMed

    Yang, Mina; Choi, Rihwa; Kim, June Soo; On, Young Keun; Bang, Oh Young; Cho, Hyun-Jung; Lee, Soo-Youn

    2016-12-01

    The purpose of this study was to evaluate the performance of 16 previously published warfarin dosing algorithms in Korean patients. The 16 algorithms were selected through a literature search and evaluated using a cohort of 310 Korean patients with atrial fibrillation or cerebral infarction who were receiving warfarin therapy. A large interindividual variation (up to 11-fold) in warfarin dose was observed (median, 25 mg/wk; range, 7-77 mg/wk). Estimated dose and actual maintenance dose correlated well overall (r range, 0.52-0.73). Mean absolute error (MAE) of the 16 algorithms ranged from -1.2 to -20.1 mg/wk. The percentage of patients whose estimated dose fell within 20% of the actual dose ranged from 1.0% to 49%. All algorithms showed poor accuracy with increased MAE in a higher dose range. Performance of the dosing algorithms was worse in patients with VKORC1 1173TC or CC than in total (r range, 0.38-0.61 vs 0.52-0.73; MAE range, -2.6 to -28.0 mg/wk vs -1.2 to -20.1 mg/wk). The algorithms had comparable prediction abilities but showed limited accuracy depending on ethnicity, warfarin dose, and VKORC1 genotype. Further studies are needed to develop genotype-guided warfarin dosing algorithms with greater accuracy in the Korean population. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  9. Comparison of filgrastim and pegfilgrastim to prevent neutropenia and maintain dose intensity of adjuvant chemotherapy in patients with breast cancer.

    PubMed

    Kourlaba, Georgia; Dimopoulos, Meletios A; Pectasides, Dimitrios; Skarlos, Dimosthenis V; Gogas, Helen; Pentheroudakis, George; Koutras, Angelos; Fountzilas, George; Maniadakis, Nikos

    2015-07-01

    The aim of this study was to compare the effectiveness of prophylactic single fixed dose of pegfilgrastim and daily administration of filgrastim on febrile neutropenia (FN), severe neutropenia, treatment delay, and dose reduction in patients with breast cancer receiving dose-dense adjuvant chemotherapy. A retrospective cohort study with 1058 breast cancer patients matched by age and chemotherapy was conducted. The primary endpoints were FN, severe (grade 3, 4) neutropenia, dose reduction (>10 % reduction of the dose planned), and treatment delay (dose given more than 2 days later). Eighteen episodes of FN (3.4%) in the filgrastim group and 23 (4.3%) in the pegfilgrastim group (p = 0.500) were recorded. More than half of the total episodes (27/41) occurred during the first 4 cycles of treatment. Patients who received filgrastim were almost three times more likely to experience a severe neutropenia episode and were significantly more likely to experience a dose reduction (18.5%) compared to those who received pegfilgrastim (10.8%) (p < 0.001). The percentage of patients, who received their planned dose on time, was significantly lower in patients receiving filgrastim (58%) compared to those receiving pegfilgrastim (72.4%, p < 0.001). No significant difference was detected on FN rate between daily administration of filgrastim and single administration of pegfilgrastim. However, patients receiving pegfilgrastim had a significantly lower rate of severe neutropenia, as well as dose reduction and treatment delay, thus, achieving a higher dose density.

  10. Patterns of Opioid Use in Sickle Cell Disease

    PubMed Central

    Han, Jin; Saraf, Santosh L.; Zhang, Xu; Gowhari, Michel; Molokie, Robert E.; Hassan, Johara; Alhandalous, Chaher; Jain, Shivi; Younge, Jewel; Abbasi, Taimur; Machado, Roberto F.; Gordeuk, Victor R.

    2016-01-01

    Pain, the hallmark complication of sickle cell disease (SCD), is largely managed with opioid analgesics in the United States, but comprehensive data regarding the long-term use of opioids in this patient population is lacking. The pain medication prescription records from a cohort of 203 SCD patients were analyzed. Twenty-five percent were not prescribed opioid medications while 47% took only short-acting opioids, 1% took only long-acting opioids, and 27% took a combination of short-acting and long-acting opioids. The median (interquartile range) daily opioid dose was 6.1 mg (1.7-26.3 mg) of oral morphine equivalents, which is lower than the published opioid use among patients with other pain syndromes. The dose of opioids correlated with the number of admissions due to vaso-occlusive crisis (VOC) (r=0.53, p<0.001). When the patients were grouped into quartiles based on daily dose opioid use, a logistic regression model showed that history of avascular necrosis (AVN) (OR 2.87, 95% CI: 1.37-6.02, p=0.005), 25-OHD levels (OR 0.59, 95% CI: 0.38-0.93, p=0.024) and total bilirubin concentration (OR 0.64, 95% CI: 0.42-0.99, p=0.043) were independently associated with opioid use quartiles. In conclusion, doses and types of opioid medications used by adult SCD patients vary widely. Our findings implicate AVN and lower vitamin D levels as factors associated with higher opioid use. They also suggest an association of higher bilirubin levels, possibly suggesting higher hemolytic rate, with lower opioid use. PMID:27466799

  11. WISE-2005: Adrenergic Responses Before and After 60 Days of 6 Degree Head-Down Bed-Rest in Women

    NASA Technical Reports Server (NTRS)

    Edgell, H.; Dyson, K.; Shoemaker, J. K.; Custaud, M. A.; Arbeille, Ph.; Greaves, D.; Hughson, R. L.; Hughson, R. L.

    2006-01-01

    Sixteen women who participated in the WISE-2005 headdown bed rest (HDBR) were studied before and on day 56 of bed rest to test the hypothesis that chronic changes in circulating norepinephrine (NOR) would change the response to adrenergic receptor agonists. Five minute infusions of 2 doses of isoproterenol (ISO), and 2 doses of NOR were administered while heart rate (HR), mean arterial pressure (MAP) and total peripheral resistance (TPR) were measured. Before HDBR, the higher dose of ISO increased HR by 13 beats/min (P

  12. Joint minimization of uplink and downlink whole-body exposure dose in indoor wireless networks.

    PubMed

    Plets, D; Joseph, W; Vanhecke, K; Vermeeren, G; Wiart, J; Aerts, S; Varsier, N; Martens, L

    2015-01-01

    The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism.

  13. Joint Minimization of Uplink and Downlink Whole-Body Exposure Dose in Indoor Wireless Networks

    PubMed Central

    Plets, D.; Joseph, W.; Vanhecke, K.; Vermeeren, G.; Wiart, J.; Aerts, S.; Varsier, N.; Martens, L.

    2015-01-01

    The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism. PMID:25793213

  14. Evaluation of an iterative model-based CT reconstruction algorithm by intra-patient comparison of standard and ultra-low-dose examinations.

    PubMed

    Noël, Peter B; Engels, Stephan; Köhler, Thomas; Muenzel, Daniela; Franz, Daniela; Rasper, Michael; Rummeny, Ernst J; Dobritz, Martin; Fingerle, Alexander A

    2018-01-01

    Background The explosive growth of computer tomography (CT) has led to a growing public health concern about patient and population radiation dose. A recently introduced technique for dose reduction, which can be combined with tube-current modulation, over-beam reduction, and organ-specific dose reduction, is iterative reconstruction (IR). Purpose To evaluate the quality, at different radiation dose levels, of three reconstruction algorithms for diagnostics of patients with proven liver metastases under tumor follow-up. Material and Methods A total of 40 thorax-abdomen-pelvis CT examinations acquired from 20 patients in a tumor follow-up were included. All patients were imaged using the standard-dose and a specific low-dose CT protocol. Reconstructed slices were generated by using three different reconstruction algorithms: a classical filtered back projection (FBP); a first-generation iterative noise-reduction algorithm (iDose4); and a next generation model-based IR algorithm (IMR). Results The overall detection of liver lesions tended to be higher with the IMR algorithm than with FBP or iDose4. The IMR dataset at standard dose yielded the highest overall detectability, while the low-dose FBP dataset showed the lowest detectability. For the low-dose protocols, a significantly improved detectability of the liver lesion can be reported compared to FBP or iDose 4 ( P = 0.01). The radiation dose decreased by an approximate factor of 5 between the standard-dose and the low-dose protocol. Conclusion The latest generation of IR algorithms significantly improved the diagnostic image quality and provided virtually noise-free images for ultra-low-dose CT imaging.

  15. Development of Radiation-Resistant In-Water Wireless Transmission System Using Light Emitting Diodes and Photo Diodes

    NASA Astrophysics Data System (ADS)

    Takeuchi, T.; Shibata, H.; Otsuka, N.; Uehara, T.; Tsuchiya, K.; Shibagaki, T.; Komanome, H.

    2016-10-01

    Several kinds of commercially available light emitting diodes (LED) and photo diodes (PD) were irradiated with 60Co gamma ray up to 1 MGy for development of a radiation-resistant in-water wireless transmission system using visible light. The lens parts of the LEDs turned brown by the irradiation and their colors became dark with the absorbed dose. The total luminous fluxes decreased with the absorbed dose and the LED with shorter emission wavelength had the higher decrease rate. Meanwhile, the current-voltage characteristics hardly changed. These results indicate that the decreases of the total luminous flux of the LEDs were mainly caused not by the degradation of the semiconductor parts but by the coloring of the lens parts by the irradiation. On the other hand, the light sensitivities of the PDs decreased with the absorbed dose. The PDs with the window part which turned a darker color had the higher decrease rate. These results indicate that the decreases of light sensitivities of the PDs were also mainly caused by the coloring of the resin parts by the irradiation. If the wireless transmission is performed using the candidate LED and PD between 5 meters in water, using a few LEDs and PDs, the PD's output current generated by the emission light of the LED is estimated to be detectable even considering the effects of the absorption of the light in water and the increased dark current by the irradiation. Therefore, a radiation resistant in-water transmission system can be constructed using commercially available LEDs and PDs in principle.

  16. Effects of aeration on water quality from septic system leachfields.

    PubMed

    Potts, David A; Görres, Josef H; Nicosia, Erika L; Amador, José A

    2004-01-01

    We conducted a pilot-scale study at a research facility in southeastern Connecticut to assess the effects of leachfield aeration on removal of nutrients and pathogens from septic system effluent. Treatments consisted of lysimeters periodically aerated to maintain a headspace O(2) concentration of 0.209 mol mol(-1) (AIR) or vented to an adjacent leachfield trench (LEACH) and were replicated three times. All lysimeters were dosed with effluent from a septic tank for 24 mo at a rate of 12 cm d(-1) and subsequently for 2 mo at 4 cm d(-1). LEACH lysimeters had developed a clogging mat, or biomat, 20 mo before the beginning of our study. The level of aeration in the AIR treatment was held constant regardless of loading rate. No conventional biomat developed in the AIR treatment, whereas a biomat was present in the LEACH lysimeters. The headspace of LEACH lysimeters was considerably depleted in O(2) and enriched in CH(4), CO(2), and H(2)S relative to AIR lysimeters. Drainage water from AIR lysimeters was saturated with O(2) and had significantly lower pH, five-day biological oxygen demand (BOD(5)), and ammonium, and higher levels of nitrate and sulfate than LEACH lysimeters regardless of dosing rate. By contrast, significantly lower levels of total N and fecal coliform bacteria were observed in AIR than in LEACH lysimeters only at the higher dosing rate. No significant differences in total P removal were observed. Our results suggest that aeration may improve the removal of nitrogen, BOD(5), and fecal coliforms in leachfield soil, even in the absence of a biomat.

  17. Comparison of the efficacy of gamma and UV irradiation in sanitization of fresh carrot juice

    NASA Astrophysics Data System (ADS)

    Jo, Cheorun; Lee, Kyung Haeng

    2012-08-01

    As there is no pasteurization procedure for the manufacture of fresh vegetable juice, both industry and consumers have sought a method for improving the storage stability and shelf-life of this category of products. In this study, the effects of commercially available, non-thermal pasteurization processes, such as gamma and UV irradiation, were compared for their efficacy in sanitizing fresh carrot juice (FCJ). FCJ was manufactured, packaged, and gamma irradiated with doses of 0, 1, 3, and 5 kGy. The manufactured FCJ was also passed through 4 UV light lamps at doses of 3.67, 4.69, and 6.50 kGy. The total aerobic bacterial count of the FCJ approached the legal limit (105 CFU/mL) after manufacturing. Both treatments were effective in reducing the number of total aerobic bacteria, and the reduced number was maintained during storage for 7 days. Gamma irradiation was more effective in suppressing microbial growth during storage. When the doses for UV treatment and gamma irradiation were higher, the inactivation effects were higher. The reduction of ascorbic acid content was greater upon gamma irradiation than UV treatment. No difference was found in the contents of flavonoids and polyphenols in FCJ after either treatment. After 3 days of refrigerated storage, the sensory scores of gamma- or UV-irradiated FCJ were superior to those of the control. The results indicate that both non-thermal treatments were effective in improving storage stability and extending shelf-life, but gamma irradiation was slightly better in suppressing microbial growth after treatment.

  18. [Ketamine as anesthetic agent in electroconvulsion therapy].

    PubMed

    Janke, C; Bumb, J M; Aksay, S S; Thiel, M; Kranaster, L; Sartorius, A

    2015-05-01

    Electroconvulsive therapy (ECT) is a well-established, safe and effective treatment for severe psychiatric disorders. Ketamine is known as a core medication in anesthesiology and has recently gained interest in ECT practice as there are three potential advantages: (1) ketamine has no anticonvulsive actions, (2) according to recent studies ketamine could possess a unique intrinsic antidepressive potential and (3) ketamine may exhibit neuroprotective properties, which again might reduce the risk of cognitive side effects associated with ECT. The use of ketamine in psychiatric patients has been controversially discussed due to its dose-dependent psychotropic and psychotomimetic effects. This study was carried out to test if the occurrence of side effects is comparable and if seizure quality is better with ketamine when compared to thiopental. This retrospective study analyzed a total of 199 patients who received ketamine anesthesia for a total of 2178 ECT sessions. This cohort was compared to patients who were treated with thiopental for 1004 ECT sessions. A repeated measurement multiple logistic regression analysis revealed significant advantages in the ketamine group for seizure concordance and postictal suppression (both are surrogates for central inhibition). S-ketamin also necessitated the use of a higher dose of urapidil and a higher maximum postictal heart frequency. Clinically relevant psychiatric side effects were rare in both groups. No psychiatric side effects occurred in the subgroup of patients with schizophrenia (ketamine: n = 30). The mean dose of S-ketamine used increased in the first years but stabilized at 63 mg per patient in 2014. From these experiences it can be concluded that S-ketamine can be recommended at least as a safe alternative to barbiturates.

  19. Impact of Calcium and Two Doses of Vitamin D on Bone Metabolism in the Elderly: A Randomized Controlled Trial.

    PubMed

    Rahme, Maya; Sharara, Sima Lynn; Baddoura, Rafic; Habib, Robert H; Halaby, Georges; Arabi, Asma; Singh, Ravinder J; Kassem, Moustapha; Mahfoud, Ziyad; Hoteit, Maha; Daher, Rose T; Bassil, Darina; El Ferkh, Karim; El-Hajj Fuleihan, Ghada

    2017-07-01

    The optimal dose of vitamin D to optimize bone metabolism in the elderly is unclear. We tested the hypothesis that vitamin D, at a dose higher than recommended by the Institute of Medicine (IOM), has a beneficial effect on bone remodeling and mass. In this double-blind trial we randomized 257 overweight elderly subjects to receive 1000 mg of elemental calcium citrate/day, and the daily equivalent of 3750 IU/day or 600 IU/day of vitamin D3 for 1 year. The subjects' mean age was 71 ± 4 years, body mass index 30 ± 4 kg/m 2 , 55% were women, and 222 completed the 12-month follow-up. Mean serum 25 hydroxyvitamin D (25OHD) was 20 ng/mL, and rose to 26 ng/mL in the low-dose arm, and 36 ng/mL in the high-dose arm, at 1 year (p < 0.05). Plasma parathyroid hormone, osteocalcin, and C-terminal telopeptide (Cross Laps) levels decreased significantly by 20% to 22% in both arms, but there were no differences between the two groups for any variable, at 6 or 12 months, with the exception of serum calcitriol, which was higher in the high-dose group at 12 months. Bone mineral density (BMD) increased significantly at the total hip and lumbar spine, but not the femoral neck, in both study arms, whereas subtotal body BMD increased in the high-dose group only, at 1 year. However, there were no significant differences in percent change BMD between the two study arms at any skeletal site. Subjects with serum 25OHD <20 ng/mL and PTH level >76 pg/mL showed a trend for higher BMD increments at all skeletal sites, in the high-dose group, that reached significance at the hip. Adverse events were comparable in the two study arms. This controlled trial shows little additional benefit in vitamin D supplementation at a dose exceeding the IOM recommendation of 600 IU/day on BMD and bone markers, in overweight elderly individuals. © 2017 American Society for Bone and Mineral Research. © 2017 American Society for Bone and Mineral Research.

  20. Weighted concentration of sup 137 Cs equivalent in foodstuffs in Kuwait from June 1986 to December 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakir, Y.Y.; Sayed, A.M.; Salem, M.S.

    1990-06-01

    The weighted monthly concentration of {sup 137}Cs equivalent (WMC) for various types of foodstuffs imported from June 1986 to December 1988 are discussed. The data presented are based on total concentration of {sup 137}Cs equivalent. The concentration was found below the disqualifying level applied in Kuwait. The radioactive contamination was higher in milk and baby milk relative to other types of foodstuffs. The calculation of Kuwait's disqualifying levels are based on the annual dose equivalent of 1 mSv (100 mrem). The measured WMC for most types of foodstuffs represents a small fraction to the annual dose limit recommended for themore » general public.« less

  1. Gadolinium-enhanced cardiovascular magnetic resonance: administered dose in relationship to United States Food and Drug Administration (FDA) guidelines.

    PubMed

    Nacif, Marcelo S; Arai, Andrew E; Lima, Joao A C; Bluemke, David A

    2012-02-29

    Myocardial late gadolinium enhancement was originally validated using higher than label-recommended doses of gadolinium chelate. The objective of this study was to evaluate available evidence for various gadolinium dosing regimens used for CMR. The relationship of gadolinium dose warnings (due to nephrogenic systemic fibrosis) announced in 2008 to gadolinium dosing regimens was also examined. We conducted a meta-analysis of peer reviewed publications from January, 2004 to December, 2010. Major subject search headings (MeSh) terms from the National Library of Medicine's PubMed were: contrast media, gadolinium, heart, magnetic resonance imaging; searches were limited to human studies with abstracts published in English. Case reports, review articles, editorials, MRA related papers and all reports that did not indicate gadolinium type or weight-based dose were excluded. For all included references, full text was available to determine the total administered gadolinium dose on a per kg basis. Average and median dose values were weighted by the number of subjects in each study. 399 publications were identified in PubMed; 233 studies matched the inclusion criteria, encompassing 19,934 patients with mean age 54.2 ± 11.4 (range 9.3 to 76 years). 34 trials were related to perfusion testing and 199 to myocardial late gadolinium enhancement. In 2004, the weighted-median and weighted-mean contrast dose were 0.15 and 0.16 ± 0.06 mmol/kg, respectively. Median contrast doses for 2005-2010 were: 0.2 mmol/kg for all years, respectively. Mean contrast doses for the years 2005-2010 were: 0.19 ± 0.03, 0.18 ± 0.04, 0.18 ± 0.10, 0.18 ± 0.03, 0.18 ± 0.04 and 0.18 ± 0.04 mmol/kg, respectively (p for trend, NS). Gadopentetate dimeglumine was the most frequent gadolinium type [114 (48.9%) studies]. No change in mean gadolinium dose was present before, versus after the Food and Drug Administration (FDA) black box warning (p > 0.05). Three multi-center dose ranging trials have been published for cardiac MRI applications. CMR studies in the peer-reviewed published literature routinely use higher gadolinium doses than regulatory agencies indicated in the package leaflet. Clinical trials should be supported to determine the appropriate doses of gadolinium for CMR studies.

  2. Response functions for computing absorbed dose to skeletal tissues from photon irradiation—an update

    NASA Astrophysics Data System (ADS)

    Johnson, Perry B.; Bahadori, Amir A.; Eckerman, Keith F.; Lee, Choonsik; Bolch, Wesley E.

    2011-04-01

    A comprehensive set of photon fluence-to-dose response functions (DRFs) is presented for two radiosensitive skeletal tissues—active and total shallow marrow—within 15 and 32 bone sites, respectively, of the ICRP reference adult male. The functions were developed using fractional skeletal masses and associated electron-absorbed fractions as reported for the UF hybrid adult male phantom, which in turn is based upon micro-CT images of trabecular spongiosa taken from a 40 year male cadaver. The new DRFs expand upon both the original set of seven functions produced in 1985, and a 2007 update calculated under the assumption of secondary electron escape from spongiosa. In this study, it is assumed that photon irradiation of the skeleton will yield charged particle equilibrium across all spongiosa regions at energies exceeding 200 keV. Kerma coefficients for active marrow, inactive marrow, trabecular bone and spongiosa at higher energies are calculated using the DRF algorithm setting the electron-absorbed fraction for self-irradiation to unity. By comparing kerma coefficients and DRF functions, dose enhancement factors and mass energy-absorption coefficient (MEAC) ratios for active marrow to spongiosa were derived. These MEAC ratios compared well with those provided by the NIST Physical Reference Data Library (mean difference of 0.8%), and the dose enhancement factors for active marrow compared favorably with values calculated in the well-known study published by King and Spiers (1985 Br. J. Radiol. 58 345-56) (mean absolute difference of 1.9 percentage points). Additionally, dose enhancement factors for active marrow were shown to correlate well with the shallow marrow volume fraction (R2 = 0.91). Dose enhancement factors for the total shallow marrow were also calculated for 32 bone sites representing the first such derivation for this target tissue.

  3. High-dose baclofen for the treatment of alcohol dependence (BACLAD study): a randomized, placebo-controlled trial.

    PubMed

    Müller, Christian A; Geisel, Olga; Pelz, Patricia; Higl, Verena; Krüger, Josephine; Stickel, Anna; Beck, Anne; Wernecke, Klaus-Dieter; Hellweg, Rainer; Heinz, Andreas

    2015-08-01

    Previous randomized, placebo-controlled trials (RCTs) assessing the efficacy of the selective γ-aminobutyric acid (GABA)-B receptor agonist baclofen in the treatment of alcohol dependence have reported divergent results, possibly related to the low to medium dosages of baclofen used in these studies (30-80mg/d). Based on preclinical observations of a dose-dependent effect and positive case reports in alcohol-dependent patients, the present RCT aimed to assess the efficacy and safety of individually titrated high-dose baclofen for the treatment of alcohol dependence. Out of 93 alcohol-dependent patients initially screened, 56 were randomly assigned to a double-blind treatment with individually titrated baclofen or placebo using dosages of 30-270mg/d. The multiple primary outcome measures were (1) total abstinence and (2) cumulative abstinence duration during a 12-week high-dose phase. More patients of the baclofen group maintained total abstinence during the high-dose phase than those receiving placebo (15/22, 68.2% vs. 5/21, 23.8%, p=0.014). Cumulative abstinence duration was significantly higher in patients given baclofen compared to patients of the placebo group (mean 67.8 (SD 30) vs. 51.8 (SD 29.6) days, p=0.047). No drug-related serious adverse events were observed during the trial. Individually titrated high-dose baclofen effectively supported alcohol-dependent patients in maintaining alcohol abstinence and showed a high tolerability, even in the event of relapse. These results provide further evidence for the potential of baclofen, thereby possibly extending the current pharmacological treatment options in alcohol dependence. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.

  4. Response functions for computing absorbed dose to skeletal tissues from photon irradiation--an update.

    PubMed

    Johnson, Perry B; Bahadori, Amir A; Eckerman, Keith F; Lee, Choonsik; Bolch, Wesley E

    2011-04-21

    A comprehensive set of photon fluence-to-dose response functions (DRFs) is presented for two radiosensitive skeletal tissues-active and total shallow marrow-within 15 and 32 bone sites, respectively, of the ICRP reference adult male. The functions were developed using fractional skeletal masses and associated electron-absorbed fractions as reported for the UF hybrid adult male phantom, which in turn is based upon micro-CT images of trabecular spongiosa taken from a 40 year male cadaver. The new DRFs expand upon both the original set of seven functions produced in 1985, and a 2007 update calculated under the assumption of secondary electron escape from spongiosa. In this study, it is assumed that photon irradiation of the skeleton will yield charged particle equilibrium across all spongiosa regions at energies exceeding 200 keV. Kerma coefficients for active marrow, inactive marrow, trabecular bone and spongiosa at higher energies are calculated using the DRF algorithm setting the electron-absorbed fraction for self-irradiation to unity. By comparing kerma coefficients and DRF functions, dose enhancement factors and mass energy-absorption coefficient (MEAC) ratios for active marrow to spongiosa were derived. These MEAC ratios compared well with those provided by the NIST Physical Reference Data Library (mean difference of 0.8%), and the dose enhancement factors for active marrow compared favorably with values calculated in the well-known study published by King and Spiers (1985 Br. J. Radiol. 58 345-56) (mean absolute difference of 1.9 percentage points). Additionally, dose enhancement factors for active marrow were shown to correlate well with the shallow marrow volume fraction (R(2) = 0.91). Dose enhancement factors for the total shallow marrow were also calculated for 32 bone sites representing the first such derivation for this target tissue.

  5. RESPONSE FUNCTIONS FOR COMPUTING ABSORBED DOSE TO SKELETAL TISSUES FROM PHOTON IRRADIATION – AN UPDATE

    PubMed Central

    Johnson, Perry; Bahadori, Amir; Eckerman, Keith; Lee, Choonsik; Bolch, Wesley E.

    2014-01-01

    A comprehensive set of photon fluence-to-dose response functions (DRFs) are presented for two radiosensitive skeletal tissues – active and total shallow marrow – within 15 and 32 bones sites, respectively, of the ICRP reference adult male. The functions were developed using fractional skeletal masses and associated electron absorbed fractions as reported for the UF hybrid adult male phantom, which in turn is based upon microCT images of trabecular spongiosa taken from a 40-year male cadaver. The new DRFs expand upon both the original set of seven functions produced in 1985, as well as a 2007 update calculated under the assumption of secondary electron escape from spongiosa. In the present study, it is assumed that photon irradiation of the skeleton will yield charged particle equilibrium across all spongiosa regions at energies exceeding 200 keV. Kerma factors for active marrow, inactive marrow, trabecular bone, and spongiosa at higher energies are calculated using the DRF algorithm setting the electron absorbed fraction for self-irradiation to unity. By comparing kerma factors and DRF functions, dose enhancement factors and mass energy-absorption coefficient (MEAC) ratios for active marrow to spongiosa were derived. These MEAC ratios compared well with those provided by the NIST Physical Reference Data Library (mean difference of 0.8%), and the dose enhancement factors for active marrow compared favorably with values calculated in the well-known study published by King and Spiers (1985) (mean absolute difference of 1.9 percentage points). Additionally, dose enhancement factors for active marrow were shown to correlate well with the shallow marrow volume fraction (R2 = 0.91). Dose enhancement factors for the total shallow marrow were also calculated for 32 bone sites PMID:21427484

  6. Comparison of the effects of three different Baccaurea angulata whole fruit juice doses on plasma, aorta and liver MDA levels, antioxidant enzymes and total antioxidant capacity.

    PubMed

    Ibrahim, Muhammad; Mikail, Maryam Abimbola; Ahmed, Idris Adewale; Hazali, Norazlanshah; Abdul Rasad, Mohammad Syaiful Bahari; Abdul Ghani, Radiah; Hashim, Ridzwan; Arief, Solachuddin Jahuari; Md Isa, Muhammad Lokman; Draman, Samsul

    2017-05-17

    Baccaurea angulata (common names: belimbing dayak or belimbing hutan) is a Malaysian underutilized fruit. The preliminary work on B. angulata fruit juice showed that it possesses antioxidant properties. Therefore, further work is needed to confirm the efficacy and proper dosage of B. angulata as a potential natural antioxidant. The present study was thus carried out to compare the effects of three different B. angulata whole fruit (WF) juice doses administered at nutritional doses of 0.50, 1.00 and 1.50 ml/kg/day on plasma, aorta and liver malondialdehyde (MDA) levels, antioxidant enzymes (superoxide dismutase, glutathione peroxidase and catalase) as well as total antioxidant capacity in rabbits fed high-cholesterol diet. Thirty-five male rabbits of New Zealand strain were randomly assigned to seven groups. For 12 weeks, group CH was fed 1% cholesterol diet only; group C1 was fed 1% cholesterol diet and 0.50 ml/kg/day B. angulata WF juice; group C2 was fed 1% cholesterol diet and 1.00 ml/kg/day B. angulata WF juice; group C3 was fed 1% cholesterol diet and 1.50 ml/kg/day B. angulata WF juice; group N was fed standard pellet only; group N1 was fed standard pellet and 0.50 ml/kg/day B. angulata WF juice; and group N2 was fed standard pellet and 1.00 ml/kg/day B. angulata WF juice. The three doses reduced the formation of MDA and enhanced the expression of endogenous antioxidant enzymes. The highest dose used (1.50 ml/kg/day) was, however, seen as the most potent. Higher doses of B. angulata juice exerted better antioxidant activity.

  7. Disposition and metabolism of codeine after single and chronic doses in one poor and seven extensive metabolisers.

    PubMed

    Chen, Z R; Somogyi, A A; Reynolds, G; Bochner, F

    1991-04-01

    1. The pharmacokinetics, metabolism and partial clearances of codeine to morphine, norcodeine and codeine-6-glucuronide after single (30 mg) and chronic (30 mg 8 h for seven doses) administration of codeine were studied in eight subjects (seven extensive and one poor metaboliser of dextromethorphan). Codeine, codeine-6-glucuronide, morphine and norcodeine were measured by high performance liquid chromatographic assays. 2. After the single dose, the time to achieve maximum plasma codeine concentrations was 0.97 +/- 0.31 h (mean +/- s.d.) and for codeine-6-glucuronide it was 1.28 +/- 0.49 h. The plasma AUC of codeine-6-glucuronide was 15.8 +/- 4.5 times higher than that of codeine. The AUC of codeine in saliva was 3.4 +/- 1.1 times higher than that in plasma. The elimination half-life of codeine was 3.2 +/- 0.3 h and that of codeine-6-glucuronide was 3.2 +/- 0.9 h. 3. The renal clearance of codeine was 183 +/- 59 ml min-1 and was inversely correlated with urine pH (r = 0.81). These data suggest that codeine undergoes filtration at the glomerulus, tubular secretion and passive reabsorption. The renal clearance of codeine-6-glucuronide was 55 +/- 21 ml min-1, and was not correlated with urine pH. Its binding to human plasma was less than 10%. These data suggest that codeine-6-glucuronide undergoes filtration at the glomerulus and tubular reabsorption. This latter process is unlikely to be passive. 4. After chronic dosing, the pharmacokinetics of codeine and codeine-6-glucuronide were not significantly different from the single dose pharmacokinetics. 5. After the single dose, 86.1 +/- 11.4% of the dose was recovered in urine, of which 59.8 +/- 10.3% was codeine-6-glucuronide, 7.1 +/- 1.1% was total morphine, 6.9 +/- 2.1% was total norcodeine and 11.8 +/- 3.9% was unchanged codeine. These recoveries were not significantly different (P greater than 0.05) after chronic administration. 6. After the single dose, the partial clearance to morphine was 137 +/- 31 ml min-1 in the seven extensive metabolisers and 8 ml min-1 in the poor metaboliser; to norcodeine the values were 103 +/- 33 ml min-1 and 90 ml min-1; to codeine-6-glucuronide the values were 914 +/- 129 ml min-1 and 971 ml min-1; and intrinsic clearance was 1568 +/- 103 ml min-1 and 1450 ml min-1. These values were not significantly (P greater than 0.05) altered by chronic administration.(ABSTRACT TRUNCATED AT 400 WORDS)

  8. The development of fetal dosimetry and its application to A-bomb survivors exposed in utero.

    PubMed

    Chen, Jing

    2012-03-01

    The cohort of the atomic bomb survivors of Hiroshima and Nagasaki comprises the major basis for investigations of health effects induced by ionising radiation in humans. To study the health effects associated with radiation exposure before birth, fetal dosimetry is needed if significant differences exist between the fetal absorbed dose and the mother's uterine dose. Combining total neutron and gamma ray free-in-air fluences at 1 m above ground with fluence-to-absorbed dose conversion coefficients, fetal doses were calculated for various exposure orientations at the ground distance of 1500 m from the hypocentres in Hiroshima and Nagasaki. The results showed that the mother's uterine dose can serve as a good surrogate for the dose of the embryo and fetus in the first trimester. However, significant differences exist between doses of the fetus of different ages. If the mother's uterine dose were used as a surrogate, doses to the fetus in the last two trimesters could be overestimated by more than 20 % for exposure orientations facing towards and away from the hypocentre while significantly underestimated for lateral positions relative to the hypocentre. In newer fetal models, the brain is modelled for all fetal ages. Brain doses to the 3-month fetus are generally higher than those to an embryo and fetus of other ages. In most cases, brain absorbed doses differ significantly from the doses to the entire fetal body. In order to accurately assess radiation effects to the fetal brain, it is necessary to determine brain doses separately.

  9. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devic, S; Tomic, N; DeBlois, F

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response bymore » using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.« less

  10. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami

    2014-05-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less

  11. Preparation of metallic nanoparticles by irradiation in starch aqueous solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemţanu, Monica R., E-mail: monica.nemtanu@inflpr.ro; Braşoveanu, Mirela, E-mail: monica.nemtanu@inflpr.ro; Iacob, Nicuşor, E-mail: monica.nemtanu@inflpr.ro

    Colloidal silver nanoparticles (AgNPs) were synthesized in a single step by electron beam irradiation reduction of silver ions in aqueous solution containing starch. The nanoparticles were characterized by spectrophotocolorimetry and compared with those obtained by chemical (thermal) reduction method. The results showed that the smaller sizes of AgNPs were prepared with higher yields as the irradiation dose increased. The broadening of particle size distribution occurred by increasing of irradiation dose and dose rate. Chromatic parameters such as b* (yellow-blue coordinate), C* (chroma) and ΔE{sub ab} (total color difference) could characterize the nanoparticles with respect of their concentration. Hue angle h{supmore » o} was correlated to the particle size distribution. Experimental data of the irradiated samples were also subjected to factor analysis using principal component extraction and varimax rotation in order to reveal the relation between dependent variables and independent variables and to reduce their number. The radiation-based method provided silver nanoparticles with higher concentration and narrower size distribution than those produced by chemical reduction method. Therefore, the electron beam irradiation is effective for preparation of silver nanoparticles using starch aqueous solution as dispersion medium.« less

  12. Back pain and exposure to whole body vibration in helicopter pilots.

    PubMed

    Bongers, P M; Hulshof, C T; Dijkstra, L; Boshuizen, H C; Groenhout, H J; Valken, E

    1990-08-01

    In a questionnaire survey the prevalence of back pain in 163 helicopter pilots was compared to that in a control group of 297 non-flying air force officers who underwent the same pre-employment medical examination. Since pilots document their hours of flight in a personal flight log, an accurate estimate of the duration of exposure could be made. In addition, vibration levels of the helicopters were measured and an accumulative vibration dose was calculated for each pilot. 'Transient' back pain of a short duration was more frequent amongst the pilots compared to the control group, and the prevalence of 'chronic' back pain of a persistent nature was also higher amongst the helicopter pilots. Transient back pain seemed to be most strongly related to the average hours of flight per day, whereas chronic back pain was more closely related to total hours of flight or the accumulative vibration dose. A significant higher prevalence of this chronic back pain was observed only after 2000 hours of flight or a vibration dose of 400 m2h/s4. The observed health effects may be due to vibration or constrained posture but are most likely due to concomitant exposure to both factors.

  13. Effect of dose rate on residual γ-H2AX levels and frequency of micronuclei in X-irradiated mouse lymphocytes.

    PubMed

    Turner, H C; Shuryak, I; Taveras, M; Bertucci, A; Perrier, J R; Chen, C; Elliston, C D; Johnson, G W; Smilenov, L B; Amundson, S A; Brenner, D J

    2015-03-01

    The biological risks associated with low-dose-rate (LDR) radiation exposures are not yet well defined. To assess the risk related to DNA damage, we compared the yields of two established biodosimetry end points, γ-H2AX and micronuclei (MNi), in peripheral mouse blood lymphocytes after prolonged in vivo exposure to LDR X rays (0.31 cGy/min) vs. acute high-dose-rate (HDR) exposure (1.03 Gy/min). C57BL/6 mice were total-body irradiated with 320 kVP X rays with doses of 0, 1.1, 2.2 and 4.45 Gy. Residual levels of total γ-H2AX fluorescence in lymphocytes isolated 24 h after the start of irradiation were assessed using indirect immunofluorescence methods. The terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay was used to determine apoptotic cell frequency in lymphocytes sampled at 24 h. Curve fitting analysis suggested that the dose response for γ-H2AX yields after acute exposures could be described by a linear dependence. In contrast, a linear-quadratic dose-response shape was more appropriate for LDR exposure (perhaps reflecting differences in repair time after different LDR doses). Dose-rate sparing effects (P < 0.05) were observed at doses ≤2.2 Gy, such that the acute dose γ-H2AX and TUNEL-positive cell yields were significantly larger than the equivalent LDR yields. At the 4.45 Gy dose there was no difference in γ-H2AX expression between the two dose rates, whereas there was a two- to threefold increase in apoptosis in the LDR samples compared to the equivalent 4.45 Gy acute dose. Micronuclei yields were measured at 24 h and 7 days using the in vitro cytokinesis-blocked micronucleus (CBMN) assay. The results showed that MNi yields increased up to 2.2 Gy with no further increase at 4.45 Gy and with no detectable dose-rate effect across the dose range 24 h or 7 days post exposure. In conclusion, the γ-H2AX biomarker showed higher sensitivity to measure dose-rate effects after low-dose LDR X rays compared to MNi formation; however, confounding factors such as variable repair times post exposure, increased cell killing and cell cycle block likely contributed to the yields of MNi with accumulating doses of ionizing radiation.

  14. What dose of tranexamic acid is most effective and safe for adult patients undergoing cardiac surgery?

    PubMed

    Hodgson, Sam; Larvin, Joseph T; Dearman, Charles

    2015-09-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: what dose of tranexamic acid is most effective and safe for adult patients undergoing cardiac surgery? Altogether 586 papers were found using the reported search, of which 12 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Current evidence shows clinical benefit of using high-dose tranexamic acid (>80 mg/kg total dose) as opposed to low-dose tranexamic acid (<50 mg/kg total dose) in cardiac surgery with cardiopulmonary bypass. Evidence from a large randomized controlled trial shows that patients receiving high-dose tranexamic acid lose less blood postoperatively than patients receiving low-dose tranexamic acid (590 vs 820 ml, P = 0.01). Patients receiving high-dose tranexamic acid also require fewer units of blood product transfusion (2.5 units vs 4.1 units; P = 0.02) and are less likely to undergo repeat surgery to achieve haemostasis. This effect is larger in those who are at high risk of bleeding. Several prospective studies comparing doses found no difference in clinical outcomes between high- and low-dose regimens, but excluded patients at high risk of bleeding. However, data from numerous observational studies demonstrate that tranexamic acid use is associated with an increased risk of postoperative seizure; one analysis showed tranexamic acid use to be a very strong independent predictor (odds ratio = 14.3, P < 0.001). There is also evidence that this risk of seizure is dose-dependent, with the greatest risk at higher doses of tranexamic acid. We conclude that, in general, patients with a high risk of bleeding should receive high-dose tranexamic acid, while those at low risk of bleeding should receive low-dose tranexamic acid with consideration given to potential dose-related seizure risk. We recommend the regimens of high-dose (30 mg kg(-1) bolus + 16 mg kg(-1) h(-1) + 2 mg kg(-1) priming) and low-dose (10 mg kg(-1) bolus + 1 mg kg(-1) h(-1) + 1 mg kg(-1) priming) tranexamic acid, as these are well established in terms of safety profile and have the strongest evidence for efficacy. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. The safety and efficacy of dexmedetomidine-remifentanil in children undergoing flexible bronchoscopy

    PubMed Central

    Li, Xia; Wang, Xue; Jin, Shuguang; Zhang, Dongsheng; Li, Yanuo

    2017-01-01

    Abstract Flexible bronchoscopy is more and more used for diagnosis and management of various pulmonary diseases in pediatrics. As poor coordination of children, the procedure is usually performed under general anesthesia with spontaneous or controlled ventilation to increase children and bronchoscopists’ safety and comfort. Previous studies have reported that dexmedetomidine (DEX) could be safely and effectively used for flexible bronchoscopy in both adulate and children. However, there is no trial to evaluate the dose-finding of safety and efficacy of dexmedetomidine-remifentanil (DEX-RF) in children undergoing flexible bronchoscopy. The objective of this study is to evaluate the dose-finding of safety and efficacy of DEX-RF in children undergoing flexible bronchoscopy. One hundred thirty-five children undergoing flexible bronchoscopy with DEX-RF were divided into 3 groups: Group DR1 (n = 47, DEX infusion at 0.5 μg·kg–1 for 10 minutes, then adjusted to 0.5–0.7 μg kg–1 h–1; RF infusion at 0.5 μg kg–1 for 2 minutes, then adjusted to 0.05–0.2 μg kg–1 min–1), Group DR2 (n = 43, DEX infusion at 1 μg kg–1 for 10 minutes, then adjusted to 0.5–0.7 μg kg–1 h–1; RF infusion at 1 μg kg–1 for 2 minutes, then adjusted to 0.05–0.2 μg kg–1 min–1), Group DR3 (n = 45, DEX infusion at 1.5 μg kg–1 for 10 minutes, then adjusted to 0.5–0.7 μg kg–1 h–1; RF infusion at 1 μg kg–1 for 2 minutes, then adjusted to 0.05–0.2 μg kg–1 min–1). Ramsay sedation scale of the 3 groups was maintained 3. Anesthesia onset time, total number of intraoperative children movements, hemodynamics (heart rate, arterial pressure, pulse oxygen saturation (SpO2), respiratory rate), total cumulative dose of dexmedetomidine and remifentanil, the amount of midazolam and lidocaine, time to first dose of rescue midazolam and lidocaine, postoperative recovery time, adverse events, bronchoscopist satisfaction score were recorded. Anesthesia onset time was significantly shorter in DR3 group (14.23 ± 5.45 vs 14.45 ± 5.12 vs 11.13 ± 4.51 minutes, respectively, of DR1, DR2, DR3, P = 0.003). Additionally, the perioperative hemodynamic profile was more stable in group DR3 than that in the other 2 groups. Total number of children movements during flexible bronchoscopy was higher in DR1 group than the other 2 groups (46.81% 22/47 vs 34.88% 15/43 vs 17.78% 8/45, respectively, of DR1, DR2, DR3, P = 0.012). Total doses of rescue midazolam and lidocaine were significantly higher in DR1 and DR2 groups than that of DR3 group (P = 0.000). The time to first dose of rescue midazolam and lidocaine was significantly longer in DR3 group than DR1 and DR2 groups (P = 0.000). Total cumulative dose of dexmedetomidine was more in DR2 and DR3 groups (P = 0.000), while the amount of remifentanil was more in DR1 and DR2 groups (P = 0.000). The time to recovery for discharge from the PACU was significantly shorter in DR1 group compared with the other 2 groups (P = 0.000). Results from bronchoscopist satisfaction score showed significantly higher in DR2 and DR3 groups than that of DR1 group (P = 0.025). There were significant differences among the 3 groups in terms of the overall incidence of hypertension, tachycardia, hypoxemia, and cough (P < 0.05). Though it required longer recovery time, high dose of DEX-RF, which provided better stable hemodynamic profiles and bronchoscopist satisfaction score, less amount of rescue scheme, and children movements, could be safely and efficacy used in children undergoing flexible bronchoscopy. PMID:28296782

  16. Joint Services Electronics Program.

    DTIC Science & Technology

    1987-03-31

    58 (no previous unit) Unit 18 Adaptive Algorithms for Identification. Filtering. Control. and S ignal P rocessin g...two new faculty. Professors Arun and Wah. Finally. a total of six new faculty in the areas of adaptive and nonlinear systems. communication systems. and...previously), we observed an additional higher binding energy site at 2.6 eV The Sb coverage in the E, site increased ,xith ion dose and a model was developed

  17. Association of Dietary Vitamin A and β-Carotene Intake with the Risk of Lung Cancer: A Meta-Analysis of 19 Publications.

    PubMed

    Yu, Na; Su, Xinming; Wang, Zanfeng; Dai, Bing; Kang, Jian

    2015-11-11

    Whether dietary β-carotene and vitamin A intake protect against lung cancer risk is not clear. Therefore, we performed this meta-analysis to investigate the association between them. The related articles were searched using the databases PubMed and the Web of Knowledge up to May 2015. We used the random-effect model to estimate the relative risk (RR) and their 95% CI. Small-study effect was assessed using Egger's test. In total, 19 studies comprising 10,261 lung cancer cases met the inclusion criteria. The pooled RR and their 95% CI was 0.855 (0.739-0.989) for higher category of dietary vitamin A intake and lung cancer risk, especially among Asian populations and in the cohort studies. Evidence from 18 studies suggested that higher category of dietary β-carotene intake could reduce lung cancer risk (0.768 (0.675-0.874)).The associations were also significant in American and Asian populations. In conclusions, higher category of dietary β-carotene and vitamin A intakes could reduce the risk of lung cancer. However, the dose-response analysis was not performed due to the limited data in each individual study. Due to this limitation, further studies with detailed dose, cases and person-years for β-carotene and vitamin A of each category are wanted to assess this dose-response association.

  18. Outcomes of first IVF/ICSI in young women with diminished ovarian reserve.

    PubMed

    Cohen, Jonathan; Mounsambote, Leonisse; Prier, Perrine; Mathieu d'ARGENT, Emmanuelle; Selleret, Lise; Chabbert-Buffet, Nathalie; Delarouziere, Vanina; Levy, Rachel; Darai, Emile; Antoine, Jean-Marie

    2017-08-01

    There is no consensual definition of diminished ovarian reserve and the best therapeutic strategy has not yet been demonstrated. We performed a retrospective study to evaluate outcomes following a first in-vitro fertilization/intra-cytoplasmic sperm injection (IVF/ICSI) cycle in young women with diminished ovarian reserve. Women with tubal factor, endometriosis or previous stimulation cycle were excluded. We defined diminished ovarian reserve as women ≤38 years with an AMH ≤1.1 ng/mL or antral follicular count ≤7. Among 59 IVF/ICSI cycles (40% IVF/60% ICSI), the pregnancy rate was 17% (10/59) and live birth rate 8.5% (5/59). Miscarriage rate was 50%. Baseline characteristics and IVF outcomes of the pregnant and not pregnant women were compared. No differences in age, antral follicular count, AMH, protocol used or number of harvested oocytes were found between the groups. A higher gonadotropin starting dose in the pregnancy group (397.5±87 IU vs. 314.8±103 IU; P=0.02) and a trend to a higher total dose received (4720±1349 IU vs. 3871±1367 IU; P=0.07) were noted. The present study confirms that women with diminished ovarian reserve have low live birth rates after a first IVF-ICSI cycle and that a higher gonadotropin starting dose might be associated with better outcomes.

  19. Long-Term Results After High-Dose Radiotherapy and Adjuvant Hormones in Prostate Cancer: How Curable Is High-Risk Disease?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zapatero, Almudena, E-mail: azapatero.hlpr@salud.madrid.org; Garcia-Vicente, Feliciano; Martin de Vidales, Carmen

    Purpose: To analyze long-term outcome and prognostic factors for high-risk prostate cancer defined by National Comprehensive Cancer Network criteria treated with high-dose radiotherapy and androgen deprivation in a single institution. Methods and Materials: A total of 306 patients treated between 1995 and 2007 in a radiation dose-escalation program fulfilled the National Comprehensive Cancer Network high-risk criteria. Median International Commission on Radiation Units and Measurements radiation dose was 78 Gy (range, 66.0-84.1 Gy). Long-term androgen deprivation (LTAD) was administered in 231 patients, short-term androgen deprivation (STAD) in 59 patients, and no hormones in 16 patients. The Phoenix (nadir plus 2 ng/mL)more » consensus definition was used for biochemical control. Multivariate analysis was performed to determine the independent prognostic impact of clinical and treatment factors. Median follow-up time was 64 months (range, 24-171 months). Results: The actuarial overall survival at 5 and 10 years was 95.7% and 89.8%, respectively, and the corresponding biochemical disease-free survival (bDFS) was 89.5% and 67.2%, respectively. Fourteen patients (4.6%) developed distant metastasis. Multivariate analysis showed that Gleason score >7 (p = 0.001), pretreatment prostate-specific antigen (PSA) level >20 ng/mL (p = 0.037), higher radiation dose (p = 0.005), and the use of adjuvant LTAD vs. STAD (p = 0.011) were independent prognostic factors affecting bDFS in high-risk disease. The 5-year bDFS for patients treated with LTAD plus radiotherapy dose >78 Gy was 97%. Conclusions: For high-risk patients the present series showed that the use of LTAD in conjunction with higher doses (>78 Gy) of radiotherapy was associated with improved biochemical tumor control. We observed that the presence of Gleason sum >7 and pretreatment PSA level >20 ng/mL in the same patient represents a 6.8 times higher risk of PSA failure. These men could be considered for clinical trials with addition of novel agents.« less

  20. Radon 222 in drinking water resources of Iran: A systematic review, meta-analysis and probabilistic risk assessment (Monte Carlo simulation).

    PubMed

    Keramati, Hassan; Ghorbani, Raheb; Fakhri, Yadolah; Mousavi Khaneghah, Amin; Conti, Gea Oliveri; Ferrante, Margherita; Ghaderpoori, Mansour; Taghavi, Mahmoud; Baninameh, Zahra; Bay, Abotaleb; Golaki, Mohammad; Moradi, Bigard

    2018-05-01

    The current study was performed to review the conducted studies regarding the concentration of radon 222 in the tap drinking water; furthermore, by estimation of ingestion and inhalation effective dose, the health risk assessment in the adults and children using MCS technique was assessed. All related studies published among January 1990 to October 2016; were screened in the available databases such as Web of Science, PubMed, Science Direct, Scopus, SID, and Irandoc. The total effective dose was estimated by calculating E ing (Effective dose of ingestion) and E inh (Effective dose of inhalation) by Monte Carlo simulation (MCS) method. The range of ND ─ 40.9 Bq/L for radon 222 in water resources was proposed after evaluation of data collected from 13 studies with 1079 samples. The overall concentration of radon 222 in drinking water in Iran was 3.98: 95%CI (3.79 ─ 4.17 Bq/L). Also, the effective ingestion dose of radon 222 in adults age groups was 1.35 times higher than children. The rank order of drinking water resources based on the concentration of radon 222 was Spring > Spring and Well > Well > Spring and Qanat > Tap water. The overall concentration of radon 222 in drinking water in Iran was lower than WHO and EPA standard limits. Also, the rank order regarding area studied based on the concentration of radon 222 was Gillan > Mashhad > Mazandaran > Kerman > Yazd > Tehran > Kermanshah > Golestan > Hormozgan. The effective ingestion dose of radon 222 to consumers in the Gillan, Mashhad, Mazandaran, and Kerman were higher than WHO guidance (0.1 mSv/y). Also except consumers in the Hormozgan, inhalation effective dose radon 222, in the other investigated areas were higher than WHO guidance (0.1 mSv/y). Therefore, it is recommended to conduct the required programs regarding control and elimination of radon 222 concentration in Iranian drinking water supply. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Change in Practice over Four Decades in the Management of Graves' Disease in Scotland.

    PubMed

    Smith, D M; Dutta, S; Ahmed, F; Thaha, M A

    2016-01-01

    There is continuing debate on the optimal treatment for Grave's thyrotoxicosis with a resultant variation in clinical practice. The present study aimed to ascertain changes in practice in the treatment of Grave's thyrotoxicosis in Tayside, Scotland, over the past four decades. Methods. The "Scottish automated follow-up register" (SAFUR) was queried to identify all patients treated for Grave's thyrotoxicosis from 1968 to 2007 inclusive. Patients were divided into 4 groups (Groups A to D) according to the decades. Demographic profile, treatment modalities, radioactive iodine (RAI) dose, and recurrence rates were studied and outcomes were compared by χ (2) test and ANOVA using SPSS v15.0. A p value of < 0.05 was considered significant. Results. Altogether, 3737 patients were diagnosed with Grave's thyrotoxicosis over the 4 decades. Use of RAI has increased from 43.1% in Group A to 68% in Group D (p < 0.001). The dose of RAI has increased (p < 0.001) and there has been a reduction in recurrence rate with higher dose of RAI. Surgical intervention rates decreased from 55.3% to 12.3% (p < 0.001) over time. Conclusions. Analysis of a large dataset of patients with Grave's thyrotoxicosis suggests increasing use of RAI as the preferred first line of treatment. Furthermore, using a single higher dose of RAI and adoption of total thyroidectomy have decreased recurrence rates.

  2. Change in Practice over Four Decades in the Management of Graves' Disease in Scotland

    PubMed Central

    Smith, D. M.; Dutta, S.; Ahmed, F.; Thaha, M. A.

    2016-01-01

    There is continuing debate on the optimal treatment for Grave's thyrotoxicosis with a resultant variation in clinical practice. The present study aimed to ascertain changes in practice in the treatment of Grave's thyrotoxicosis in Tayside, Scotland, over the past four decades. Methods. The “Scottish automated follow-up register” (SAFUR) was queried to identify all patients treated for Grave's thyrotoxicosis from 1968 to 2007 inclusive. Patients were divided into 4 groups (Groups A to D) according to the decades. Demographic profile, treatment modalities, radioactive iodine (RAI) dose, and recurrence rates were studied and outcomes were compared by χ 2 test and ANOVA using SPSS v15.0. A p value of < 0.05 was considered significant. Results. Altogether, 3737 patients were diagnosed with Grave's thyrotoxicosis over the 4 decades. Use of RAI has increased from 43.1% in Group A to 68% in Group D (p < 0.001). The dose of RAI has increased (p < 0.001) and there has been a reduction in recurrence rate with higher dose of RAI. Surgical intervention rates decreased from 55.3% to 12.3% (p < 0.001) over time. Conclusions. Analysis of a large dataset of patients with Grave's thyrotoxicosis suggests increasing use of RAI as the preferred first line of treatment. Furthermore, using a single higher dose of RAI and adoption of total thyroidectomy have decreased recurrence rates. PMID:27313946

  3. Immune tolerance improves the efficacy of enzyme replacement therapy in canine mucopolysaccharidosis I

    PubMed Central

    Dickson, Patricia; Peinovich, Maryn; McEntee, Michael; Lester, Thomas; Le, Steven; Krieger, Aimee; Manuel, Hayden; Jabagat, Catherine; Passage, Merry; Kakkis, Emil D.

    2008-01-01

    Mucopolysaccharidoses (MPSs) are lysosomal storage diseases caused by a deficit in the enzymes needed for glycosaminoglycan (GAG) degradation. Enzyme replacement therapy with recombinant human α-l-iduronidase successfully reduces lysosomal storage in canines and humans with iduronidase-deficient MPS I, but therapy usually also induces antibodies specific for the recombinant enzyme that could reduce its efficacy. To understand the potential impact of α-l-iduronidase–specific antibodies, we studied whether inducing antigen-specific immune tolerance to iduronidase could improve the effectiveness of recombinant iduronidase treatment in canines. A total of 24 canines with MPS I were either tolerized to iduronidase or left nontolerant. All canines received i.v. recombinant iduronidase at the FDA-approved human dose or a higher dose for 9–44 weeks. Nontolerized canines developed iduronidase-specific antibodies that proportionally reduced in vitro iduronidase uptake. Immune-tolerized canines achieved increased tissue enzyme levels at either dose in most nonreticular tissues and a greater reduction in tissue GAG levels, lysosomal pathology, and urinary GAG excretion. Tolerized MPS I dogs treated with the higher dose received some further benefit in the reduction of GAGs in tissues, urine, and the heart valve. Therefore, immune tolerance to iduronidase improved the efficacy of enzyme replacement therapy with recombinant iduronidase in canine MPS I and could potentially improve outcomes in patients with MPS I and other lysosomal storage diseases. PMID:18654665

  4. Previous Dosage of Allopurinol Is a Strong Determinant of Febuxostat Efficacy.

    PubMed

    Koide, Hiroyoshi; Hira, Daiki; Tsujimoto, Masayuki; Katsube, Yurie; Minegaki, Tetsuya; Uzu, Takashi; Ikeda, Yoshito; Morita, Shin-Ya; Nishiguchi, Kohshi; Terada, Tomohiro

    2017-01-01

    Febuxostat has currently played pivotal role in the treatment of hyperuricemia, but there is little comprehensive information for the determinants of individual difference in efficacy of febuxostat. Therefore, the present study, a retrospective investigation, was carried out to analyze the effects of patient characteristics on the efficacy of febuxostat. A total of 225 patients who were continuously prescribed the same dose of febuxostat for 8-12 weeks from the initial therapy were enrolled in the present study. The data, including patient information and laboratory data, were collected from electronic medical records. Serum urate lowering effects of febuxostat were evaluated by calculating the change in serum urate level at baseline and at 8-12 weeks after starting febuxostat. The multiple regression analysis showed the change in serum urate level was significantly lower in male patients and in those with a lower baseline serum urate level, higher previous dose of allopurinol, lower dose of febuxostat and lower body surface area-unadjusted estimated glomerular filtration rate. Concomitantly administered drugs did not show a significantly influence on the efficacy of febuxostat. In conclusion, it should be noted that the serum urate lowering efficacy of febuxostat may decrease in patients with a higher previous dose of allopurinol, renal impairment or male patients. The basic findings of the present study are believed to contribute to the proper use of febuxostat.

  5. ASCORBIC ACID RETENTION AND COLOR OF STRAWBERRIES AS RELATED TO LOW-LEVEL IRRADIATION AND STORAGE TIME

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wells, C.E.; Tichenor, D.A.; Martin, D.C.

    1963-01-01

    Freshly picked strawberries were irradiated in a gamma source and ascorbic acid (ASA) and its oxidative breakdown products were measured at intervals during 3 to 6 months' storage. Reduced ASA, dehydroascorbic acid (DHA), diketogulonic acid (DKA), and total ASA were determined in unirradiated strawberries and in strawberries receiving 0.3 and 0.8 Mrad. Irradiation caused a significant loss of total ASA. Storage at 35 un. Concent 85% F for 180 days resulted in further losses, most of which occurred during the first 95 days. Addition of a glucose oxidase packet to atmospheric packs did not affect retention of total ASA. Amore » significant amount of reduced ASA was destroyed by irradiation, the loss being greater at the higher level used. Relatively large amounts er irradiation in the presence of almost complete retention of total ASA indicated that the degradation followed the usual pattern: reduced ASA to DHA to DKA. After 180 days storage, practically all of the reduced ASA was destroyed in air-packed irradiated samples, but comparable glucose-oxidase-packed samples retained 33 to 47% of their original reduced ASA. Measurement of the Gardner a color value revealed a significant able color variability among samples. Color losses were higher at higher doses. (H.R.D.)« less

  6. Metabolic Disposition of Osimertinib in Rats, Dogs, and Humans: Insights into a Drug Designed to Bind Covalently to a Cysteine Residue of Epidermal Growth Factor Receptor.

    PubMed

    Dickinson, Paul A; Cantarini, Mireille V; Collier, Jo; Frewer, Paul; Martin, Scott; Pickup, Kathryn; Ballard, Peter

    2016-08-01

    Preclinical and clinical studies were conducted to determine the metabolism and pharmacokinetics of osimertinib and key metabolites AZ5104 and AZ7550. Osimertinib was designed to covalently bind to epidermal growth factor receptors, allowing it to achieve nanomolar cellular potency (Finlay et al., 2014). Covalent binding was observed in incubations of radiolabeled osimertinib with human and rat hepatocytes, human and rat plasma, and human serum albumin. Osimertinib, AZ5104, and AZ7550 were predominantly metabolized by CYP3A. Seven metabolites were detected in human hepatocytes, also observed in rat or dog hepatocytes at similar or higher levels. After oral administration of radiolabeled osimertinib to rats, drug-related material was widely distributed, with the highest radioactivity concentrations measured at 6 hours postdose in most tissues; radioactivity was detectable in 42% of tissues 60 days postdose. Concentrations of [(14)C]-radioactivity in blood were lower than in most tissues. After the administration of a single oral dose of 20 mg of radiolabeled osimertinib to healthy male volunteers, ∼19% of the dose was recovered by 3 days postdose. At 84 days postdose, mean total radioactivity recovery was 14.2% and 67.8% of the dose in urine and feces. The most abundant metabolite identified in feces was AZ5104 (∼6% of dose). Osimertinib accounted for ∼1% of total radioactivity in the plasma of non-small cell lung cancer patients after 22 days of 80-mg osimertinib once-daily treatment; the most abundant circulatory metabolites were AZ7550 and AZ5104 (<10% of total osimertinib-related material). Osimertinib is extensively distributed and metabolized in humans and is eliminated primarily via the fecal route. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  7. The peripheral quantitative computed tomographic and densitometric analysis of skeletal tissue in male Wistar rats after chromium sulfate treatment.

    PubMed

    Bieńko, Marek; Radzki, Radosław Piotr; Wolski, Dariusz

    2017-09-21

    This study evaluates the effects of three different doses of chromium sulphate on bone density and the tomographic parameters of skeletal tissue of rats. The experiment was performed on 40 male Wistar rats which received, by gavage, during 90 days, a chromium sulphate in either a daily dose of 400, 600 or 800 µg/kg BW. At the end of experiment, the rats were scanned using the densitometry method (DXA) to determine the bone mineral density, bone mineral content of total skeleton and vertebral column (L2-L4) and parameters of body composition (Lean Mass and Fat Mass). The isolated femora were scanned using peripheral a quantitative computed tomography method (pQCT) for a separate analysis of the trabecular and cortical bone tissue. The ultimate strength, work to ultimate and the Young modulus of femora was also investigated by the three-point bending test. The negative impact of chromium was observed in relation to bone tissue. All doses significantly decreased total skeleton density and mineral content, and also had impact upon the isolated femora and vertebral column. Trabecular volumetric bone mineral density and trabecular bone mineral content measured by pQCT in distal femur metaphysis were significantly lower in the experimental groups than in the control. Higher doses of chromium also significantly decreased values of ultimate strength and Young modulus in the investigated femora. The results of the experiment demonstrate that chromium sulphate is dose dependent, and exerts a disadvantageous effect on the skeleton, as it decreases bone density and resistance.

  8. Adrenaline (epinephrine) dosing period and survival after in-hospital cardiac arrest: a retrospective review of prospectively collected data.

    PubMed

    Warren, Sam A; Huszti, Ella; Bradley, Steven M; Chan, Paul S; Bryson, Chris L; Fitzpatrick, Annette L; Nichol, Graham

    2014-03-01

    Expert guidelines for treatment of cardiac arrest recommend administration of adrenaline (epinephrine) every three to five minutes. However, the effects of different dosing periods of epinephrine remain unclear. We sought to evaluate the association between epinephrine average dosing period and survival to hospital discharge in adults with an in-hospital cardiac arrest (IHCA). We performed a retrospective review of prospectively collected data on 20,909 IHCA events from 505 hospitals participating in the Get With The Guidelines-Resuscitation (GWTG-R) quality improvement registry. Epinephrine average dosing period was defined as the time between the first epinephrine dose and the resuscitation endpoint, divided by the total number of epinephrine doses received subsequent to the first epinephrine dose. Associations with survival to hospital discharge were assessed by using generalized estimating equations to construct multivariable logistic regression models. Compared to a referent epinephrine average dosing period of 4 to <5 min per dose, survival to hospital discharge was significantly higher in patients with the following epinephrine average dosing periods: for 6 to <7 min/dose, adjusted odds ratio [OR], 1.41 (95%CI: 1.12, 1.78); for 7 to <8 min/dose, adjusted OR, 1.30 (95%CI: 1.02, 1.65); for 8 to <9 min/dose, adjusted OR, 1.79 (95%CI: 1.38, 2.32); for 9 to <10 min/dose, adjusted OR, 2.17 (95%CI: 1.62, 2.92). This pattern was consistent for both shockable and non-shockable cardiac arrest rhythms. Less frequent average epinephrine dosing than recommended by consensus guidelines was associated with improved survival of in-hospital cardiac arrest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Potentiation of low dose ketamine effects by naltrexone: potential implications for the pharmacotherapy of alcoholism.

    PubMed

    Krystal, John H; Madonick, Steven; Perry, Edward; Gueorguieva, Ralitza; Brush, Laura; Wray, Yola; Belger, Aysenil; D'Souza, Deepak Cyril

    2006-08-01

    The interplay of opiate and NMDA glutamate receptors may contribute to psychosis, cognitive function, alcoholism, and substance dependence. Ketamine and ethanol block the NMDA glutamate receptor. The purpose of this randomized double-blind, placebo-controlled human laboratory study was to evaluate whether the interactive effects of drugs acting at opiate and NMDA glutamate receptors might partially explain the efficacy of naltrexone for the treatment of alcoholism, that is, whether naltrexone 25 mg pretreatment would modulate ketamine effects in healthy human subjects. Two groups of healthy subjects were studied. An initial group (n=31) received a perception-altering subanesthetic dose of ketamine (bolus of 0.23 mg/kg over 1 min followed by a 60-min infusion of 0.58 mg/kg or saline bolus and infusion). A second group (n=24) completed the same testing procedures, but received a subperceptual ketamine dose (bolus 0.081 mg/kg over 10 min followed by an infusion of 0.4 mg/kg/h). Ketamine produced positive symptoms, negative symptoms, emotional discomfort, and cognitive effects as measured by the Positive and Negative Syndrome Scale (PANSS) in a dose-related fashion. The lower ketamine dose produced subjective effects similar to two standard ethanol drinks, whereas the higher ketamine dose produced effects similar to five standard drinks. Although naltrexone produced no significant behavioral effects, it significantly magnified the increase in the total PANSS score produced by the lower subperceptual dose of ketamine, but not the higher perception-altering dose of ketamine. These data suggest that the interplay of opiate receptor antagonism and NMDA receptor antagonism may be relevant to the protective effects of naltrexone on alcohol consumption via potentiation of dysphoric effects associated with the NMDA receptor antagonist effects of ethanol. However, these data suggest that at levels of NMDA receptor antagonism associated with heavy drinking, this protective effect of naltrexone on drinking is no longer present.

  10. Assessment of radiation doses from residential smoke detectors that contain americium-241

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Donnell, F.R.; Etnier, E.L.; Holton, G.A.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq (3 ..mu..Ci) americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv (0.4 prem) to 20 nSv (2 ..mu..rem) for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 ..mu..Svmore » (0.0006 to 8 mrem) to total body and from 0.06 to 800 ..mu..Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft/sup 2/).« less

  11. Dose escalation pharmacokinetics of intranasal scopolamine gel formulation.

    PubMed

    Wu, Lei; Boyd, Jason L; Daniels, Vernie; Wang, Zuwei; Chow, Diana S-L; Putcha, Lakshmi

    2015-02-01

    Astronauts experience Space Motion Sickness requiring treatment with an anti-motion sickness medication, scopolamine during space missions. Bioavailability after oral administration of scopolamine is low and variable, and absorption form transdermal patch is slow and prolonged. Intranasal administration achieves faster absorption and higher bioavailability of drugs that are subject to extrahepatic, first pass metabolism after oral dosing. We examined pharmacokinetics of 0.1, 0.2, and 0.4 mg doses of the Investigational New Drug formulation of intranasal scopolamine gel (INSCOP) in 12 healthy subjects using a randomized, double-blind cross-over study design. Subjects received one squirt of 0.1 g of gel containing either 0.1 mg or 0.2 mg/0.1 mL scopolamine or placebo in each nostril. Serial blood samples and total urine voids were collected after dosing and drug concentrations were determined using a modified LC-MS-MS method. Results indicate dose-linear pharmacokinetics of scopolamine with linear increases in Cmax and AUC within the dose range tested. Plasma drug concentrations were significantly lower in females than in males after administration of 0.4 dose. All three doses were well tolerated with no unexpected or serious adverse side effects reported. These results suggest that intranasal scopolamine gel formulation (INSCOP) offers a fast, reliable, and safe alternative for the treatment of motion sickness. © 2014, The American College of Clinical Pharmacology.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ene, D.; Andersson, K.; Jensen, M.

    The European Spallation Source (ESS) will produce tritium via spallation and activation processes during operational activities. Within the location of ESS facility in Lund, Sweden site it is mandatory to demonstrate that the management strategy of the produced tritium ensures the compliance with the country regulation criteria. The aim of this paper is to give an overview of the different aspects of the tritium management in ESS facility. Besides the design parameter study of the helium coolant purification system of the target the consequences of the tritium releasing into the environment were also analyzed. Calculations show that the annual releasemore » of tritium during the normal operations represents a small fraction from the estimated total dose. However, more refined calculations of migration of activated-groundwater should be performed for higher hydraulic conductivities, with the availability of the results on soil examinations. With the assumption of 100% release of tritium to the atmosphere during the occurring of the extreme accidents, it was found as well that the total dose complies with the constraint. (authors)« less

  13. A comparative analysis of warfarin and low-dose heparin as thromboembolism prophylaxis in total hip replacement patinets.

    PubMed Central

    Ritter, M A; HamiltonCW

    1975-01-01

    Warfarin, low-dose heparin, or a combination of low-dose heparin and hydrocortisone was administered to 300 patients undergoing total hip replacement. The lowest incidence of thromboembolic (5 per cent) was attained with Warfarin. Further investigation into the method of administration of low-dose heparin is necessary before it can be used effectively as thromboembolism prophylaxis in total hip replacement patients. The addition of hydrocortisone was not found useful. PMID:1138642

  14. Diuretic effects of medetomidine compared with xylazine in healthy dogs

    PubMed Central

    Talukder, Md. Hasanuzzaman; Hikasa, Yoshiaki

    2009-01-01

    This study aimed to investigate and compare the effects of medetomidine and xylazine on diuretic and hormonal variables in healthy dogs. Five dogs, used in each of 11 groups, were injected intramuscularly with physiological saline solution (control), 5, 10, 20, 40, and 80 μg/kg of medetomidine, and 0.25, 0.5, 1, 2, and 4 mg/kg of xylazine. Urine and blood samples were taken 11 times over 24 h. Both medetomidine and xylazine increased urine production in a dose-dependent manner up to 4 h after injection, but the increase was much less with medetomidine than with xylazine at the tested doses. Urine specific gravity, pH, osmolality, and concentrations of creatinine, sodium, potassium, chloride, and arginine vasopressin (AVP) were decreased in a dose-dependent manner with both medetomidine and xylazine. Plasma osmolality and concentrations of sodium, potassium, and chloride were increased significantly with both drugs. Total amounts of urine AVP excreted and plasma AVP concentrations were significantly decreased by higher doses of medetomidine but were not significantly decreased by xylazine. Higher doses of both drugs significantly increased the plasma concentration of atrial natriuretic peptide (ANP), but the effect was greater with medetomidine than with xylazine. The results revealed that both drugs induce a profound diuresis, but medetomidine’s effect is less dose-dependent than xylazine’s effect. Although changes in plasma concentrations of AVP and ANP may partially influence the diuresis induced by medetomidine, other factors may be involved in the mechanism of the diuretic response to both drugs. Thus, both agents can be used clinically for transient but effective diuresis accompanied by sedation. PMID:19794896

  15. FAILURE OF RADIOACTIVE IODINE IN TREATMENT OF HYPERTHYROIDISM

    PubMed Central

    Schneider, David F.; Sonderman, Philip E.; Jones, Michaela F.; Ojomo, Kristin A.; Chen, Herbert; Jaume, Juan C.; Elson, Diane F.; Perlman, Scott B.; Sippel, Rebecca S.

    2015-01-01

    Introduction Persistent or recurrent hyperthyroidism after treatment with radioactive iodine (RAI) is common, and many patients require either additional doses or surgery before they are cured. The purpose of this study was to identify patterns and predictors of failure of RAI in patients with hyperthyroidism. Methods We conducted a retrospective review of patients treated with RAI from 2007–2010. Failure of RAI was defined as receipt of additional dose(s) and/or total thyroidectomy. Using a Cox proportional hazards model, we conducted univariate analysis to identify factors associated with failure of RAI. A final multivariate model was then constructed with significant (p < 0.05) variables from the univariate analysis. Results Of the 325 patients analyzed, 74 patients (22.8%) failed initial RAI treatment. 53 (71.6%) received additional RAI, 13 (17.6%) received additional RAI followed by surgery, and the remaining 8 (10.8%) were cured after thyroidectomy. The percentage of patients who failed decreased in a step-wise fashion as RAI dose increased. Similarly, the incidence of failure increased as the presenting T3 level increased. Sensitivity analysis revealed that RAI doses < 12.5 mCi were associated with failure while initial T3 and free T4 levels of at least 4.5 pg/mL and 2.3 ng/dL, respectively, were associated with failure. In the final multivariate analysis, higher T4 (HR 1.13, 95% CI 1.02–1.26, p=0.02) and methimazole treatment (HR 2.55, 95% CI 1.22–5.33, p=0.01) were associated with failure. Conclusions Laboratory values at presentation can predict which patients with hyperthyroidism are at risk for failing RAI treatment. Higher doses of RAI or surgical referral may prevent the need for repeat RAI in selected patients. PMID:25001092

  16. Failure of radioactive iodine in the treatment of hyperthyroidism.

    PubMed

    Schneider, David F; Sonderman, Philip E; Jones, Michaela F; Ojomo, Kristin A; Chen, Herbert; Jaume, Juan C; Elson, Diane F; Perlman, Scott B; Sippel, Rebecca S

    2014-12-01

    Persistent or recurrent hyperthyroidism after treatment with radioactive iodine (RAI) is common and many patients require either additional doses or surgery before they are cured. The purpose of this study was to identify patterns and predictors of failure of RAI in patients with hyperthyroidism. We conducted a retrospective review of patients treated with RAI from 2007 to 2010. Failure of RAI was defined as receipt of additional dose(s) and/or total thyroidectomy. Using a Cox proportional hazards model, we conducted univariate analysis to identify factors associated with failure of RAI. A final multivariate model was then constructed with significant (p < 0.05) variables from the univariate analysis. Of the 325 patients analyzed, 74 patients (22.8 %) failed initial RAI treatment, 53 (71.6 %) received additional RAI, 13 (17.6 %) received additional RAI followed by surgery, and the remaining 8 (10.8 %) were cured after thyroidectomy. The percentage of patients who failed decreased in a stepwise fashion as RAI dose increased. Similarly, the incidence of failure increased as the presenting T3 level increased. Sensitivity analysis revealed that RAI doses <12.5 mCi were associated with failure while initial T3 and free T4 levels of at least 4.5 pg/mL and 2.3 ng/dL, respectively, were associated with failure. In the final multivariate analysis, higher T4 (hazard ratio [HR] 1.13; 95 % confidence interval [CI] 1.02-1.26; p = 0.02) and methimazole treatment (HR 2.55; 95 % CI 1.22-5.33; p = 0.01) were associated with failure. Laboratory values at presentation can predict which patients with hyperthyroidism are at risk for failing RAI treatment. Higher doses of RAI or surgical referral may prevent the need for repeat RAI in selected patients.

  17. Measurements of the Martian Gamma/Neutron Spectra with MSL/RAD

    NASA Astrophysics Data System (ADS)

    Kohler, J.; Zeitlin, C. J.; Ehresmann, B.; Wimmer-Schweingruber, R. F.; Hassler, D.; Reitz, G.; Brinza, D.; Weigle, E.; Boettcher, S.; Burmeister, S.; Guo, J.; Martin-Garcia, C.; Boehm, E.; Posner, A.; Rafkin, S. C.; Kortmann, O.

    2013-12-01

    The Radiation Assessment Detector (RAD) onboard Mars Science Laboratory's rover curiosity measures the energetic charged and neutral particle spectra and the radiation dose rate on the Martian surface. An important factor for determining the biological impact of the Martian surface radiation is the specific contribution of neutrons, which possess a high biological effectiveness. In contrast to charged particles, neutrons and gamma rays are generally only measured indirectly. Their measurement is the result of a complex convolution of the incident particle spectrum with the measurement process. We apply an inversion method to calculate the gamma/neutron spectra from the RAD neutral particle measurements. Here we show first measurements of the Martian gamma/neutron spectra and compare them to theoretical predictions. We find that the shape of the gamma spectrum is very similar to the predicted one, but with a ~50% higher intensity. The measured neutron spectrum agrees well with prediction up to ~100 MeV, but shows a considerably increased intensity for higher energies. The measured neutron spectrum translates into a radiation dose rate of 25 μGy/day and a dose equivalent rate of 106 μSv/day. This corresponds to 10% of the total surface dose rate, and 15% of the biological relevant surface dose equivalent rate on Mars. Measuring the Martian neutron spectra is an essential step for determining the mutagenic influences to past or present life at or beneath the Martian surface as well as the radiation hazard for future human exploration, including the shielding design of a potential habitat. The contribution of neutrons to the dose equivalent increases considerably with shielding thickness, so our measurements provide an important figure to mitigate cancer risk.

  18. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    PubMed

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  19. Pharmacokinetics, safety, and tolerability of rotigotine transdermal system in healthy Japanese and Caucasian subjects following multiple-dose administration.

    PubMed

    Cawello, Willi; Kim, Seong Ryul; Braun, Marina; Elshoff, Jan-Peer; Masahiro, Takeuchi; Ikeda, Junji; Funaki, Tomoo

    2016-08-01

    Rotigotine is a dopamine receptor agonist indicated for the treatment of Parkinson's disease and moderate-to-severe restless legs syndrome. Continuous transdermal delivery of rotigotine via a silicon-based patch maintains stable plasma concentrations over 24 h. The objective of the study was to evaluate the pharmacokinetics, safety, and tolerability of a multiple-dose schedule of rotigotine transdermal patch in Japanese and Caucasian subjects. In this open-label, repeated-dose, parallel-group study (ClinicalTrials.gov: NCT01854216), healthy male and female subjects of Japanese or Caucasian ethnic origin were matched by gender, body mass index, and age. Subjects underwent a 9-day patch application period. 12 Japanese and 12 Caucasian subjects were included in the pharmacokinetic analyses. Mean apparent doses (actual amount of drug delivered) increased proportionally with rotigotine nominal dosages (1, 2, and 4 mg/24 h) and were similar for both ethnic groups, with large inter-individual variability. Mean plasma concentration-time profiles for unconjugated rotigotine were similar in both ethnic groups at day 3 for each dosage. Peak concentrations (C max,ss) and area under the concentration-time curves from pre-dose to the concentration measured 24 h after administration of patch (AUC(0-24,ss)) showed similar exposure in both groups; higher values in Japanese subjects were explained by differences in body weight. For total rotigotine, C max,ss and AUC(0-24,ss) values were higher in Caucasian subjects and could be explained by small differences in apparent dose. Rotigotine was generally well tolerated following multiple applications up to 4 mg/24 h. These findings suggest similar dosage requirements for rotigotine transdermal system in Japanese and Caucasian populations.

  20. Insulin Requirements in Non-Critically Ill Hospitalized Patients With Diabetes and Steroid-Induced Hyperglycemia

    PubMed Central

    Spanakis, Elias K.; Shah, Nina; Malhotra, Keya; Kemmerer, Terri; Yeh, Hsin-Chieh; Golden, Sherita Hill

    2014-01-01

    Objective Steroid-induced hyperglycemia is common in hospitalized patients with diabetes mellitus. Guidelines for glucose management in this setting are lacking. Methods We conducted a retrospective chart review of non-critically ill patients with diabetes receiving steroids, hospitalized from January 2009 to October 2012. Fifty-eight patients were identified from 247 consults. Multivariable linear regression was used to assess median daily insulin requirements of normoglycemic patients compared with hyperglycemic patients. Results Of the 58 total patients included in our study, 20 achieved normoglycemia during admission (patient-day weighted mean blood glucose [PDWMBG] level = 154 ± 16 mg/dL) and 38 remained hyperglycemic (PDWMBG level= 243 ± 39 mg/dL; P < 0.001). There were no differences between the 2 patient groups in age, sex, race, body weight, renal function, HbA1c level, glucose-altering medications, diabetes type, or disease duration. Following multivariable adjustment, compared with hyperglycemic patients, normoglycemic patients required similar units of basal insulin (median [interquartile range])(23.6 [17.9, 31.2] vs 20.1 [16.5, 24.4]; P = 0.35); higher units of nutritional insulin (45.5 [34.2, 60.4] vs 20.1 [16.4, 24.5]; P < 0.001]; and lower units of correctional insulin (5.8 [4.1, 8.1] vs 13.0 [10.2, 16.5]; P < 0.001]). Patients achieving normoglycemia required a significantly lower percentage of correction insulin (total daily dose [TDD]: 7.4% vs 23.4%; P < 0.001) and a higher percentage of nutritional insulin (TDD: 58.1% vs 36.2%; P < 0.001) than hyperglycemic patients. There was no difference in the TDD per kilogram, TDD per milligram hydrocortisone dose, or TDD per milligram hydrocortisone dose per kilogram weight between the 2 groups. Conclusion The data suggest that non-critically ill patients with hyperglycemia receiving steroids require a higher percentage of TDD insulin therapy as nutritional insulin to achieve normoglycemia. PMID:24769781

  1. Insulin requirements in non-critically ill hospitalized patients with diabetes and steroid-induced hyperglycemia.

    PubMed

    Spanakis, Elias K; Shah, Nina; Malhotra, Keya; Kemmerer, Terri; Yeh, Hsin-Chieh; Golden, Sherita Hill

    2014-04-01

    Steroid-induced hyperglycemia is common in hospitalized patients with diabetes mellitus. Guidelines for glucose management in this setting are lacking. We conducted a retrospective chart review of non-critically ill patients with diabetes receiving steroids, hospitalized from January 2009 to October 2012. Fifty-eight patients were identified from 247 consults. Multivariable linear regression was used to assess median daily insulin requirements of normoglycemic patients compared with hyperglycemic patients. Of the 58 total patients included in our study, 20 achieved normoglycemia during admission (patient-day weighted mean blood glucose [PDWMBG] level = 154 ± 16 mg/dL) and 38 remained hyperglycemic (PDWMBG level = 243 ± 39 mg/dL; P < 0.001). There were no differences between the 2 patient groups in age, sex, race, body weight, renal function, HbA1c level, glucose-altering medications, diabetes type, or disease duration. Following multivariable adjustment, compared with hyperglycemic patients, normoglycemic patients required similar units of basal insulin (median interquartile range [IQR])(23.6 [17.9, 31.2] vs 20.1 [16.5, 24.4]; P = 0.35); higher units of nutritional insulin (45.5 [34.2, 60.4] vs 20.1 [16.4, 24.5]; P < 0.001]; and lower units of correctional insulin (5.8 [4.1, 8.1] vs 13.0 [10.2, 16.5]; P < 0.001]). Patients achieving normoglycemia required a significantly lower percentage of correction insulin (total daily dose [TDD]: 7.4% vs 23.4%; P < 0.001) and a higher percentage of nutritional insulin (TDD: 58.1% vs 36.2%; P <0.001) than hyperglycemic patients. There was no difference in the TDD per kilogram, TDD per milligram hydrocortisone dose, or TDD per milligram hydrocortisone dose per kilogram weight between the 2 groups. The data suggest that non-critically ill patients with hyperglycemia receiving steroids require a higher percentage of TDD insulin therapy as nutritional insulin to achieve normoglycemia.

  2. Impact of patient characteristics on the pharmacokinetics of corifollitropin alfa during controlled ovarian stimulation.

    PubMed

    Zandvliet, Anthe S; Prohn, Marita; de Greef, Rik; van Aarle, Frank; McCrary Sisk, Christine; Stegmann, Barbara J

    2016-07-01

    The aim of the present study was to characterize the pharmacokinetic profile of corifollitropin alfa and examine the relationships between dose, intrinsic factors [body weight, body mass index (BMI), age and race] and corifollitropin alfa pharmacokinetics. Data from five phase II and III clinical trials of corifollitropin alfa were evaluated. All subjects included in the analysis received 60 - 180 μg corifollitropin alfa for controlled ovarian stimulation in a gonadotrophin-releasing hormone antagonist protocol followed by daily recombinant follicle stimulating hormone (rFSH) from day 8 onwards. Serum corifollitropin alfa levels (across the entire range of treatment) and total follicle stimulating hormone immunoreactivity levels (up to the start of rFSH treatment) were indicators of drug exposure. The analyses were performed using a nonlinear mixed-effects modelling approach. A total of 2630 subjects were treated with corifollitropin alfa, and 2557 subjects were evaluable for analysis. Body weight, BMI and race (Asian and Black vs. Caucasian) were significant determinants of corifollitropin alfa exposure. Dose-normalized corifollitropin alfa exposure was ~89% higher in women with a body weight of 50 kg vs. 90 kg (in subjects with a similar BMI of 24 kg m(-2) ); 14% higher in women with a BMI of 18 kg m(-2) vs. 32 kg m(-2) (provided they were of similar body weight); and ~15.7% lower in Asian subjects and 13% higher in Black subjects vs. Caucasian subjects. Body weight was the major determinant of corifollitropin alfa exposure; BMI and race (Asian and Black) were also determinants but to a lesser extent and without associated effects on clinical outcomes. Corifollitropin alfa dose adjustment is indicated, based on body weight but not for BMI or race. These recommendations are consistent with the product label. © 2016 The British Pharmacological Society.

  3. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens

    2013-05-15

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposedmore » lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.« less

  4. Iron absorption from oral iron supplements given on consecutive versus alternate days and as single morning doses versus twice-daily split dosing in iron-depleted women: two open-label, randomised controlled trials.

    PubMed

    Stoffel, Nicole U; Cercamondi, Colin I; Brittenham, Gary; Zeder, Christophe; Geurts-Moespot, Anneke J; Swinkels, Dorine W; Moretti, Diego; Zimmermann, Michael B

    2017-11-01

    Current guidelines to treat iron deficiency recommend daily provision of ferrous iron divided through the day to increase absorption. However, daily dosing and split dosing might increase serum hepcidin and decrease iron absorption from subsequent doses. Our study aim was to compare iron absorption from oral iron supplements given on consecutive versus alternate days and given as single morning doses versus twice-daily split dosing. We did two prospective, open-label, randomised controlled trials assessing iron absorption using ( 54 Fe)-labelled, ( 57 Fe)-labelled, or ( 58 Fe)-labelled ferrous sulfate in iron-depleted (serum ferritin ≤25 μg/L) women aged 18-40 years recruited from ETH Zurich and the University of Zurich, Switzerland. In study 1, women were randomly assigned (1:1) to two groups. One group was given 60 mg iron at 0800 h (±1 h) on consecutive days for 14 days, and the other group was given the same doses on alternate days for 28 days. In study 2, women were assigned to two groups, stratified by serum ferritin so that two groups with similar iron statuses could be formed. One group was given 120 mg iron at 0800 h (±1 h) and the other was given the dose split into two divided doses of 60 mg at 0800 h (±1 h) and 1700 h (±1 h) for three consecutive days. 14 days after the final dose, the groups were each crossed over to the other regimen. Within-individual comparisons were done. The co-primary outcomes in both studies were iron bioavailability (total and fractional iron absorption), assessed by measuring the isotopic label abundance in erythrocytes 14 days after administration, and serum hepcidin. Group allocations in both studies were not masked and primary and safety analyses were done on an intention-to-treat basis. The studies were registered at ClinicalTrials.gov, numbers NCT02175888 (study 1) and NCT02177851 (study 2) and are complete. For study 1, 40 women were enrolled on Oct 15-29, 2015. 21 women were assigned to the consecutive-day group and 19 to the alternate-day group. At the end of treatment (14 days for the consecutive-day group and 28 days for the alternate-day group), geometric mean (-SD, +SD) cumulative fractional iron absorptions were 16·3% (9·3, 28·8) in the consecutive-day group versus 21·8% (13·7, 34·6) in the alternate-day group (p=0·0013), and cumulative total iron absorption was 131·0 mg (71·4, 240·5) versus 175·3 mg (110·3, 278·5; p=0·0010). During the first 14 days of supplementation in both groups, serum hepcidin was higher in the consecutive-day group than the alternate-day group (p=0·0031). In study 2, 20 women were enrolled between Aug 13 and 18, 2015. Ten women were assigned to receive once-daily dosing and ten were assigned to receive twice-daily divided dosing. No significant differences were seen in fractional (day 1-3 geometric mean: 11·8% [7·1, 19·4] once daily vs 13·1% [8·2, 20·7] twice daily; p=0·33) or total iron absorption (day 1-3: 44·3 mg [29·4, 66·7] once daily vs 49·4 [35·2, 69·4] twice daily; p=0·33) between the two dosing regimens. Twice-daily divided doses resulted in a higher serum hepcidin concentration than once-daily dosing (p=0·013). No grade 3 or 4 adverse events were reported in either study. In iron-depleted women, providing iron supplements daily as divided doses increases serum hepcidin and reduces iron absorption. Providing iron supplements on alternate days and in single doses optimises iron absorption and might be a preferable dosing regimen. These findings should be confirmed in iron-deficient anaemic patients. Swiss National Science Foundation, Bern, Switzerland. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Mitigation of radon and thoron decay products by filtration.

    PubMed

    Wang, Jin; Meisenberg, Oliver; Chen, Yongheng; Karg, Erwin; Tschiersch, Jochen

    2011-09-01

    Inhalation of indoor radon ((222)Rn) and thoron ((220)Rn) decay products is the most important source of exposure to ionizing radiation for the human respiratory tract. Decreasing ventilation rates due to energy saving reasons in new buildings suggest additional active mitigation techniques to reduce the exposure in homes with high radon and thoron concentrations but poor ventilation. Filtration techniques with HEPA filters and simple surgical mask material have been tested for their potential to reduce the indoor exposure in terms of the total effective dose for mixed radon and thoron indoor atmospheres. The tests were performed inside an experimental room providing stable conditions. Filtration (at filtration rates of 0.2 h(-1) and larger) removes attached radon and thoron decay products effectively but indoor aerosol as well. Therefore the concentration of unattached decay products (which have a higher dose coefficient) may increase. The decrease of the attached decay product concentrations could be theoretically described by a slowly decreasing exponential process. For attached radon decay products, it exhibited a faster but weaker removal process compared to attached thoron decay products (-70% for attached radon decay products and -80% for attached thoron decay products at a filtration rate of 0.5 h(-1) with an HEPA filter). The concentration of unattached thoron decay products increased distinctly during the filtration process (+300%) while that of unattached radon decay products rose only slightly though at a much higher level (+17%). In the theoretical description these observed differences could be attributed to the different half-lives of the nuclides. Considering both effects, reduced attached and increased unattached decay product concentrations, filtration could significantly decrease the total effective dose from thoron whereas the overall effect on radon dose is small. A permanent filtration is recommended because of the slow decrease of the thoron decay product concentrations. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Dosimetric comparison of three intensity-modulated radiation therapies for left breast cancer after breast-conserving surgery.

    PubMed

    Zhang, Huai-Wen; Hu, Bo; Xie, Chen; Wang, Yun-Lai

    2018-05-01

    This study aimed to evaluate dosimetric differences of intensity-modulated radiation therapy (IMRT) in target and normal tissues after breast-conserving surgery. IMRT five-field plan I, IMRT six-field plan II, and field-in-field-direct machine parameter optimization-IMRT plan III were designed for each of the 50 patients. One-way analysis of variance was performed to compare differences, and P < 0.05 was considered statistically significant. Homogeneity index of plan III is lower than those of plans I and II. No difference was identified in conformity index of targets. Plan I exhibited difference in mean dose (D mean ) for the heart (P < 0.05). Plan I featured smaller irradiation dose volumes in V 5 , V 20 (P < 0.05) of the left lung than II. Plan I exhibited significantly higher V 5 in the right lung than plans II and III (P < 0.05). Under plan I, irradiation dose at V 5 in the right breast is higher than that in plans II and III. Patients in plan III presented less total monitor unit and total treatment time than those in plans I and II (P < 0.05). IMRT six-field plans II, and field-in-field-direct machine parameter optimization-IMRT plans III can reduce doses and volumes to the lungs and heart better while maintaining satisfying conformity index and homogeneity index of target. Nevertheless, plan II neglects target movements caused by respiration. In the same manner, plan III can substantially reduce MU and shorten patient treatment time. Therefore, plan III, which considers target movement caused by respiration, is a more practical radiation mode. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. Single-Fraction Proton Beam Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hattangadi-Gluth, Jona A.; Chapman, Paul H.; Kim, Daniel

    2014-06-01

    Purpose/Objective(s): To evaluate the obliteration rate and potential adverse effects of single-fraction proton beam stereotactic radiosurgery (PSRS) in patients with cerebral arteriovenous malformations (AVMs). Methods and Materials: From 1991 to 2010, 248 consecutive patients with 254 cerebral AVMs received single-fraction PSRS at our institution. The median AVM nidus volume was 3.5 cc (range, 0.1-28.1 cc), 23% of AVMs were in critical/deep locations (basal ganglia, thalamus, or brainstem), and the most common prescription dose was 15 Gy(relative biological effectiveness [RBE]). Univariable and multivariable analyses were performed to assess factors associated with obliteration and hemorrhage. Results: At a median follow-up time of 35 months (range, 6-198 months),more » 64.6% of AVMs were obliterated. The median time to total obliteration was 31 months (range, 6-127 months), and the 5-year and 10-year cumulative incidence of total obliteration was 70% and 91%, respectively. On univariable analysis, smaller target volume (hazard ratio [HR] 0.78, 95% confidence interval [CI] 0.86-0.93, P<.0001), smaller treatment volume (HR 0.93, 95% CI 0.90-0.96, P<.0001), higher prescription dose (HR 1.16, 95% CI 1.07-1.26, P=.001), and higher maximum dose (HR 1.14, 95% CI 1.05-1.23, P=.002) were associated with total obliteration. Deep/critical location was also associated with decreased likelihood of obliteration (HR 0.68, 95% CI 0.47-0.98, P=.04). On multivariable analysis, critical location (adjusted HR [AHR] 0.42, 95% CI 0.27-0.65, P<.001) and smaller target volume (AHR 0.81, 95% CI 0.68-0.97, P=.02) remained associated with total obliteration. Posttreatment hemorrhage occurred in 13 cases (5-year cumulative incidence of 7%), all among patients with less than total obliteration, and 3 of these events were fatal. The most common complication was seizure, controlled with medications, both acutely (8%) and in the long term (9.1%). Conclusions: The current series is the largest modern series of PSRS for cerebral AVMs. PSRS can achieve a high obliteration rate with minimal morbidity. Post-treatment hemorrhage remains a potentially fatal risk among patients who have not yet responded to treatment.« less

  8. The radiation dosimeter on-board the FY-4 Satellite

    NASA Astrophysics Data System (ADS)

    Zhang, B.; Sun, Y.; Zhang, S.; Zhang, X.; Sun, Y.; Jing, T.

    2017-12-01

    The total radiation dose effect can lead to a decrease in the performance of satellite devices or materials. Accurately obtaining the total radiation dose during satellite operation could help to analyze the abnormality of payloads in orbit and optimize the design of radiation shielding. The radiation dosimeter is one of the space environmental monitoring devices on the "FY-4" satellite, which is a new generation of geostationary meteorological satellite. The dosimeter consists of 8 detectors, which are installed in different locations of the satellite, to obtain the total radiation dose with different shielding thickness and different orientations. To measure a total radiation dose up to 2000krad(Si), 100nm ion implantation RADFET was used. To improve the sensitivity of the dosimeter, the bias voltage of RADFET is set to 15V, and a 10V, 15-bit A/D is adopted to digitalize the RADFET's threshold voltage, which is increased as the total radiation dose grows. In addition, the temperature effect of RADFET is corrected from the measured temperature on orbit. The preliminary monitoring results show that the radiation dose is less than 35rad (Si) per day at 0.87 mm shielding thickness of equivalent aluminum in the geostationary orbit, and the dose in Y direction of the satellite is less than those in the X and Z directions. The radiation dose at the thickness of 3.87 mm equivalent aluminum is less than 1rad(Si)/day. It is found that the daily total dose measured by the dosimeter has a strong correlation with the flux of high energy electrons.

  9. Rates of Change in Naturalistic Psychotherapy: Contrasting Dose-Effect and Good-Enough Level Models of Change

    ERIC Educational Resources Information Center

    Baldwin, Scott A.; Berkeljon, Arjan; Atkins, David C.; Olsen, Joseph A.; Nielsen, Stevan L.

    2009-01-01

    Most research on the dose-effect model of change has combined data across patients who vary in their total dose of treatment and has implicitly assumed that the rate of change during therapy is constant across doses. In contrast, the good-enough level model predicts that rate of change will be related to total dose of therapy. In this study, the…

  10. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

    NASA Technical Reports Server (NTRS)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; Label, Kenneth A.; Ladbury, Raymond L.; Mondy, Timothy K.; O'Bryan, Martha V.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

  11. Delivery cost analysis of a reactive mass cholera vaccination campaign: a case study of Shanchol™ vaccine use in Lake Chilwa, Malawi.

    PubMed

    Ilboudo, Patrick G; Le Gargasson, Jean-Bernard

    2017-12-19

    Cholera is a diarrheal disease that produces rapid dehydration. The infection is a significant cause of mortality and morbidity. Oral cholera vaccine (OCV) has been propagated for the prevention of cholera. Evidence on OCV delivery cost is insufficient in the African context. This study aims to analyze Shanchol vaccine delivery costs, focusing on the vaccination campaign in response of a cholera outbreak in Lake Chilwa, Malawi. The vaccination campaign was implemented in two rounds in February and March 2016. Structured questionnaires were used to collect costs incurred for each vaccination related activity, including vaccine procurement and shipment, training, microplanning, sensitization, social mobilization and vaccination rounds. Costs collected, including financial and economic costs were analyzed using Choltool, a standardized cholera cost calculator. In total, 67,240 persons received two complete doses of the vaccine. Vaccine coverage was higher in the first round than in the second. The two-dose coverage measured with the immunization card was estimated at 58%. The total financial cost incurred in implementing the campaign was US$480275 while the economic cost was US$588637. The total financial and economic costs per fully vaccinated person were US$7.14 and US$8.75, respectively, with delivery costs amounting to US$1.94 and US$3.55, respectively. Vaccine procurement and shipment accounted respectively for 73% and 59% of total financial and economic costs of the total vaccination campaign costs while the incurred personnel cost accounted for 13% and 29% of total financial and economic costs. Cost for delivering a single dose of Shanchol was estimated at US$0.97. This study provides new evidence on economic and financial costs of a reactive campaign implemented by international partners in collaboration with MoH. It shows that involvement of international partners' personnel may represent a substantial share of campaign's costs, affecting unit and vaccine delivery costs.

  12. Age, Sex, and Dose Effects of Nonbenzodiazepine Hypnotics on Hip Fracture in Nursing Home Residents.

    PubMed

    Dore, David D; Zullo, Andrew R; Mor, Vincent; Lee, Yoojin; Berry, Sarah D

    2018-04-01

    The Food and Drug Administration recommends a reduced dose of nonbenzodiazepine hypnotics in women, yet little is known about the age-, sex-, and dose-specific effects of these drugs on risk of hip fracture, especially among nursing home (NH) residents. We estimated the age-, sex-, and dose-specific effects of nonbenzodiazepine hypnotics on the rate of hip fracture among NH residents. Case-crossover study in US NHs. A total of 691 women and 179 men with hip fracture sampled from all US long-stay NH residents. Measures of patient characteristics were obtained from linked Medicare and the Minimum Data Set (2007-2008). The outcome was hospitalization for hip fracture with surgical repair. We estimated rate ratios (RRs) and 95% confidence intervals (CIs) from conditional logistic regression models for nonbenzodiazepine hypnotics (vs nonuse) comparing 0 to 29 days before hip fracture (hazard period) with 60 to 89 and 120 to 149 days before hip fracture (control periods). We stratified analyses by age, sex, and dose. The average RR of hip fracture was 1.7 (95% CI 1.5-1.9) for any use. The RR of hip fracture was higher for residents aged ≥90 years vs <70 years (2.2 vs 1.3); however, the CIs overlapped. No differences in the effect of the hypnotic on risk of hip fracture were evident by sex. Point estimates for hip fracture were greater with high-dose versus low-dose hypnotics (RR 1.9 vs 1.6 for any use), but these differences were highly compatible with chance. The rate of hip fracture in NH residents due to use of nonbenzodiazepine hypnotics was greater among older patients than among younger patients and, possibly, with higher doses than with lower doses. When clinicians are prescribing a nonbenzodiazepine hypnotic to any NH resident, doses of these drugs should be kept as low as possible, especially among those with advanced age. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  13. Comparative pharmacokinetics and bioavailability of albendazole sulfoxide in sheep and goats, and dose-dependent plasma disposition in goats.

    PubMed

    Aksit, Dilek; Yalinkilinc, Hande Sultan; Sekkin, Selim; Boyacioğlu, Murat; Cirak, Veli Yilgor; Ayaz, Erol; Gokbulut, Cengiz

    2015-05-27

    The aims of this study were to compare the pharmacokinetics of albendazole sulfoxide (ABZ-SO, ricobendazole) in goats and sheep at a dose of 5 g/kg bodyweight (BW), after intravenous (IV) and subcutaneous (SC) administrations, and to investigate the effects of increased doses (10 and 15 mg/kg BW) on the plasma disposition of ABZ-SO in goats following SC administration. A total of 16 goats (Capra aegagrus hircus, eight males and eight females) and 8 sheep (Ovis aries, four males and four females) 12-16 months old and weighing 20-32 kg, were used. The study was designed according to two-phase crossover study protocol. In Phase-1, eight sheep were assigned as Group I and 16 goats were allocated into two groups (Group II and Group III). ABZ-SO was applied to Group I (sheep) and Group II (goats) animals subcutaneously, and to Group III (goats) animals intravenously, all at a dose rate of 5 mg/kg BW. In Phase-2, the sheep in the Group I received ABZ-SO intravenously in a dose of 5 mg/kg BW; the goats in Group II and Group III received ABZ-SO subcutaneously at a dose of 10 mg/kg and 15 mg/kg BW, respectively. Blood samples were collected from the jugular vein at different times between 1 and 120 h after drug administrations. The plasma concentrations of ABZ-SO and its metabolites were analysed by high performance liquid chromatography. In goats, the area under the curve, terminal half-life and plasma persistence of ABZ-SO were significantly smaller and shorter, respectively, compared with those observed in sheep following both IV and SC administrations at a dose of 5 mg/kg BW. On the other side, dose-dependent plasma dispositions of ABZ-SO were observed following SC administration at increased doses (10 and 15 mg/kg) in goats. Consequently, ABZ-SO might be used at higher doses to provide higher plasma concentration and thus to achieve greater efficacy against the target parasites.

  14. The long-term effects of acute exposure to ionising radiation on survival and fertility in Daphnia magna

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarapultseva, Elena I.

    The results of recent studies have provided strong evidence for the transgenerational effects of parental exposure to ionising radiation and chemical mutagens. However, the transgenerational effects of parental exposure on survival and fertility remain poorly understood. To establish whether parental irradiation can affect the survival and fertility of directly exposed organisms and their offspring, crustacean Daphnia magna were given 10, 100, 1000 and 10,000 mGy of acute γ-rays. Exposure to 1000 and 10,000 mGy significantly compromised the viability of irradiated Daphnia and their first-generation progeny, but did not affect the second-generation progeny. The fertility of F{sub 0} and F{sub 1}Daphniamore » gradually declined with the dose of parental exposure and significantly decreased at dose of 100 mGy and at higher doses. The effects of parental irradiation on the number of broods were only observed among the F{sub 0}Daphnia exposed to 1000 and 10,000 mGy, whereas the brood size was equally affected in the two consecutive generations. In contrast, the F{sub 2} total fertility was compromised only among progeny of parents that received the highest dose of 10,000 mGy. We propose that the decreased fertility observed among the F{sub 2} progeny of parents exposed to 10,000 mGy is attributed to transgenerational effects of parental irradiation. Our results also indicate a substantial recovery of the F{sub 2} progeny of irradiated F{sub 0}Daphnia exposed to the lower doses of acute γ-rays. - Highlights: • Viability of irradiated daphnids and their F{sub 1} progeny is compromised. • Viability of the F{sub 2} progeny of irradiated parents is not affected. • Total fertility of irradiated daphnids and their F{sub 1} progeny declines with the dose. • Total fertility of the F{sub 2} progeny of parents exposed to 10,000 mGy is compromised. • The decreased fertility among the F{sub 2} progeny is transgenerational phenomenon.« less

  15. In vivo stimulation of granulopoiesis by recombinant human granulocyte colony-stimulating factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohen, A.M.; Zsebo, K.M.; Inoue, H.

    1987-04-01

    Osmotic pumps containing Escherichia coli-derived recombinant human granulocyte colony-stimulating factor (rhG-CSF) were attached to indwelling jugular vein catheters and implanted subcutaneously into Golden Syrian hamsters. Within 3 days, peripheral granulocyte counts had increased > 10-fold with a concomitant 4-fold increase in total leukocytes. Microscopic examination of Wright-Giemsa-stained blood smears from rhG-CSF hamsters showed that only the neutrophil subpopulation of granulocytes had increased. After subcutaneous injection at /sup 35/S-labeled rhG-CSF doses of up to 10 ..mu..g x kg/sup -1/ x day/sup -1/ only granulocyte counts were affected. However, at higher dose levels, a transient thrombocytopenia was noted. Erythrocyte and lymphocyte/monocyte countsmore » remained unaffected by rhG-CSF over the entire dose range studied. Total leukocyte counts increased 3-fold within 12 hr after a single s.c. injection of rhG-CSF. This early effect was associated with an increase in the total number of colony-forming cells and the percent of active cycling cells in the marrow. A sustained elevation of peripheral leukocyte and marrow progenitor counts was observed following seven daily s.c. injections of rhG-CSF. The ability of rhG-CSF to increase the production and release of granulocytes from the marrow may underlie the beneficial effect it produced on the restoration of peripheral leukocyte counts in hamsters made leukopenic by treatment with 5-fluorouracil.« less

  16. Impulse control disorders in advanced Parkinson's disease with dyskinesia: The ALTHEA study.

    PubMed

    Biundo, Roberta; Weis, Luca; Abbruzzese, Giovanni; Calandra-Buonaura, Giovanna; Cortelli, Pietro; Jori, Maria Cristina; Lopiano, Leonardo; Marconi, Roberto; Matinella, Angela; Morgante, Francesca; Nicoletti, Alessandra; Tamburini, Tiziano; Tinazzi, Michele; Zappia, Mario; Vorovenci, Ruxandra Julia; Antonini, Angelo

    2017-11-01

    Impulse control disorders and dyskinesia are common and disabling complications of dopaminergic treatment in Parkinson's disease. They may coexist and are possibly related. The objectives of this study were to assess the frequency and severity of impulse control disorders in Parkinson's disease patients with dyskinesia. The ALTHEA study enrolled 251 Parkinson's disease patients with various degrees of dyskinesia severity from 11 movement disorders centers in Italy. Each patient underwent a comprehensive assessment including Unified Dyskinesia Rating Scale and the Questionnaire for Impulsive Compulsive Disorders in Parkinson Disease-Rating Scale. There was an overall 55% frequency of impulse control disorder and related behaviors (36% were clinically significant). The positive patients were younger at disease diagnosis and onset and had higher Unified Dyskinesia Rating Scale historical and total score (P = 0.001 and P = 0.02, respectively, vs negative). There was an increased frequency of clinically significant impulse control disorders in patients with severe dyskinesia (P = 0.013), a positive correlation between the questionnaire total score and dopamine agonist dose (P = 0.018), and a trend with levodopa dose. More than half of Parkinson's disease patients with dyskinesia have impulse control disorders and related behaviors, which are frequently clinically significant. Dopaminergic therapy total dose is associated with their severity. Clinicians should carefully assess patients with maladaptive behaviors and dyskinesia because they do not properly evaluate their motor and nonmotor status. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  17. SU-G-201-15: Nomogram as an Efficient Dosimetric Verification Tool in HDR Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, J; Todor, D

    Purpose: Nomogram as a simple QA tool for HDR prostate brachytherapy treatment planning has been developed and validated clinically. Reproducibility including patient-to-patient and physician-to-physician variability was assessed. Methods: The study was performed on HDR prostate implants from physician A (n=34) and B (n=15) using different implant techniques and planning methodologies. A nomogram was implemented as an independent QA of computer-based treatment planning before plan execution. Normalized implant strength (total air kerma strength Sk*t in cGy cm{sup 2} divided by prescribed dose in cGy) was plotted as a function of PTV volume and total V100. A quadratic equation was used tomore » fit the data with R{sup 2} denoting the model predictive power. Results: All plans showed good target coverage while OARs met the dose constraint guidelines. Vastly different implant and planning styles were reflected on conformity index (entire dose matrix V100/PTV volume, physician A implants: 1.27±0.14, physician B: 1.47±0.17) and PTV V150/PTV volume ratio (physician A: 0.34±0.09, physician B: 0.24±0.07). The quadratic model provided a better fit for the curved relationship between normalized implant strength and total V100 (or PTV volume) than a simple linear function. Unlike the normalized implant strength versus PTV volume nomogram which differed between physicians, a unique quadratic model based nomogram (Sk*t)/D=−0.0008V2+0.0542V+1.1185 (R{sup 2}=0.9977) described the dependence of normalized implant strength on total V100 over all the patients from both physicians despite two different implant and planning philosophies. Normalized implant strength - total V100 model also generated less deviant points distorting the smoothed ones with a significantly higher correlation. Conclusion: A simple and universal, excel-based nomogram was created as an independent calculation tool for HDR prostate brachytherapy. Unlike similar attempts, our nomogram is insensitive to implant style and does not rely on reproducing dose calculations using TG-43 formalism, thus making it a truly independent check.« less

  18. Advanced proton beam dosimetry part II: Monte Carlo vs. pencil beam-based planning for lung cancer.

    PubMed

    Maes, Dominic; Saini, Jatinder; Zeng, Jing; Rengan, Ramesh; Wong, Tony; Bowen, Stephen R

    2018-04-01

    Proton pencil beam (PB) dose calculation algorithms have limited accuracy within heterogeneous tissues of lung cancer patients, which may be addressed by modern commercial Monte Carlo (MC) algorithms. We investigated clinical pencil beam scanning (PBS) dose differences between PB and MC-based treatment planning for lung cancer patients. With IRB approval, a comparative dosimetric analysis between RayStation MC and PB dose engines was performed on ten patient plans. PBS gantry plans were generated using single-field optimization technique to maintain target coverage under range and setup uncertainties. Dose differences between PB-optimized (PBopt), MC-recalculated (MCrecalc), and MC-optimized (MCopt) plans were recorded for the following region-of-interest metrics: clinical target volume (CTV) V95, CTV homogeneity index (HI), total lung V20, total lung V RX (relative lung volume receiving prescribed dose or higher), and global maximum dose. The impact of PB-based and MC-based planning on robustness to systematic perturbation of range (±3% density) and setup (±3 mm isotropic) was assessed. Pairwise differences in dose parameters were evaluated through non-parametric Friedman and Wilcoxon sign-rank testing. In this ten-patient sample, CTV V95 decreased significantly from 99-100% for PBopt to 77-94% for MCrecalc and recovered to 99-100% for MCopt (P<10 -5 ). The median CTV HI (D95/D5) decreased from 0.98 for PBopt to 0.91 for MCrecalc and increased to 0.95 for MCopt (P<10 -3 ). CTV D95 robustness to range and setup errors improved under MCopt (ΔD95 =-1%) compared to MCrecalc (ΔD95 =-6%, P=0.006). No changes in lung dosimetry were observed for large volumes receiving low to intermediate doses (e.g., V20), while differences between PB-based and MC-based planning were noted for small volumes receiving high doses (e.g., V RX ). Global maximum patient dose increased from 106% for PBopt to 109% for MCrecalc and 112% for MCopt (P<10 -3 ). MC dosimetry revealed a reduction in target dose coverage under PB-based planning that was regained under MC-based planning along with improved plan robustness. MC-based optimization and dose calculation should be integrated into clinical planning workflows of lung cancer patients receiving actively scanned proton therapy.

  19. Advanced proton beam dosimetry part II: Monte Carlo vs. pencil beam-based planning for lung cancer

    PubMed Central

    Maes, Dominic; Saini, Jatinder; Zeng, Jing; Rengan, Ramesh; Wong, Tony

    2018-01-01

    Background Proton pencil beam (PB) dose calculation algorithms have limited accuracy within heterogeneous tissues of lung cancer patients, which may be addressed by modern commercial Monte Carlo (MC) algorithms. We investigated clinical pencil beam scanning (PBS) dose differences between PB and MC-based treatment planning for lung cancer patients. Methods With IRB approval, a comparative dosimetric analysis between RayStation MC and PB dose engines was performed on ten patient plans. PBS gantry plans were generated using single-field optimization technique to maintain target coverage under range and setup uncertainties. Dose differences between PB-optimized (PBopt), MC-recalculated (MCrecalc), and MC-optimized (MCopt) plans were recorded for the following region-of-interest metrics: clinical target volume (CTV) V95, CTV homogeneity index (HI), total lung V20, total lung VRX (relative lung volume receiving prescribed dose or higher), and global maximum dose. The impact of PB-based and MC-based planning on robustness to systematic perturbation of range (±3% density) and setup (±3 mm isotropic) was assessed. Pairwise differences in dose parameters were evaluated through non-parametric Friedman and Wilcoxon sign-rank testing. Results In this ten-patient sample, CTV V95 decreased significantly from 99–100% for PBopt to 77–94% for MCrecalc and recovered to 99–100% for MCopt (P<10−5). The median CTV HI (D95/D5) decreased from 0.98 for PBopt to 0.91 for MCrecalc and increased to 0.95 for MCopt (P<10−3). CTV D95 robustness to range and setup errors improved under MCopt (ΔD95 =−1%) compared to MCrecalc (ΔD95 =−6%, P=0.006). No changes in lung dosimetry were observed for large volumes receiving low to intermediate doses (e.g., V20), while differences between PB-based and MC-based planning were noted for small volumes receiving high doses (e.g., VRX). Global maximum patient dose increased from 106% for PBopt to 109% for MCrecalc and 112% for MCopt (P<10−3). Conclusions MC dosimetry revealed a reduction in target dose coverage under PB-based planning that was regained under MC-based planning along with improved plan robustness. MC-based optimization and dose calculation should be integrated into clinical planning workflows of lung cancer patients receiving actively scanned proton therapy. PMID:29876310

  20. Protective effects of dietary antioxidants on proton total-body irradiation-mediated hematopoietic cell and animal survival.

    PubMed

    Wambi, Chris O; Sanzari, Jenine K; Sayers, Carly M; Nuth, Manunya; Zhou, Zhaozong; Davis, James; Finnberg, Niklas; Lewis-Wambi, Joan S; Ware, Jeffrey H; El-Deiry, Wafik S; Kennedy, Ann R

    2009-08-01

    Abstract Dietary antioxidants have radioprotective effects after gamma-radiation exposure that limit hematopoietic cell depletion and improve animal survival. The purpose of this study was to determine whether a dietary supplement consisting of l-selenomethionine, vitamin C, vitamin E succinate, alpha-lipoic acid and N-acetyl cysteine could improve survival of mice after proton total-body irradiation (TBI). Antioxidants significantly increased 30-day survival of mice only when given after irradiation at a dose less than the calculated LD(50/30); for these data, the dose-modifying factor (DMF) was 1.6. Pretreatment of animals with antioxidants resulted in significantly higher serum total white blood cell, polymorphonuclear cell and lymphocyte cell counts at 4 h after 1 Gy but not 7.2 Gy proton TBI. Antioxidants significantly modulated plasma levels of the hematopoietic cytokines Flt-3L and TGFbeta1 and increased bone marrow cell counts and spleen mass after TBI. Maintenance of the antioxidant diet resulted in improved recovery of peripheral leukocytes and platelets after sublethal and potentially lethal TBI. Taken together, oral supplementation with antioxidants appears to be an effective approach for radioprotection of hematopoietic cells and improvement of animal survival after proton TBI.

  1. Comparison of the safety and efficacy of a fixed-dose combination regimen and separate formulations for pulmonary tuberculosis treatment.

    PubMed

    Wu, Jiun-Ting; Chiu, Chien-Tung; Wei, Yu-Feng; Lai, Yung-Fa

    2015-06-01

    Fixed-dose combination formulations, which simplify the administration of drugs and prevent the development of drug resistance, have been recommended as a standard anti-tuberculosis treatment regimen. However, the composition and dosage recommendations for fixed-dose combination formulations differ from those for separate formulations. Thus, questions about the effectiveness and side effects of combination formulations remain. The aim of this study was to compare the safety and efficacy of these two types of anti-tuberculosis regimens for pulmonary tuberculosis treatment. A prospective, randomized controlled study was conducted using the directly observed treatment short-course strategy. Patients were randomly allocated to one of two short-course regimens. One year after completing the treatment, these patients' outcomes were analyzed. ClinicalTrials.gov: NCT00979290. A total of 161 patients were enrolled, 142 of whom were evaluable for safety assessment. The two regimens had a similar incidence of adverse effects. In the per-protocol population, serum bilirubin concentrations at the peak level, at week 4, and at week 8 were significantly higher for the fixed-dose combination formulation than for the separate formulations. All patients had negative sputum cultures at the end of the treatment, and no relapse occurred after one year of follow-up. In this randomized study, transient higher serum bilirubin levels were noted for the fixed-dose combination regimen compared with the separate formulations during treatment. However, no significant difference in safety or efficacy was found between the groups when the directly observed treatment short-course strategy was used.

  2. 210-Polonium studies in some environmental and biological matrices of Domiasiat uranium deposit area, West Khasi Hills, Meghalaya, India.

    PubMed

    Marbaniang, Deswyn G; Poddar, Raj K; Nongkynrih, Phlis; Khathing, Darlando T

    2010-03-01

    The study was performed using a silicon surface barrier alpha spectrometer at Bhabha Atomic Research Centre, Mumbai, India. Through the study, the observed (210)Po activity in water sample from different locations in the Domiasiat area ranges from 0.04 to 0.69 Bq/l. The daily and annual intake of (210)Po through water was also estimated and the mean value of 0.72 and 263.61 Bq, respectively, were observed. It is observed that the effective doses through water were higher than the World Health Organization recommended dose of 0.05 mSv/year. The total annual effective doses through terrestrial ingestion for all the locations was studied and the mean annual effective dose was observed to be 0.315 mSv, which, when compared to the worldwide and the Indian values, was observed to be slightly higher. The mean activity in soil is found to be 124.8 +/-5.7 Bq/kg and in meat the activity is 0.43 +/-0.05 Bq/kg. In fishes, an activity of 0.48 +/-0.07 Bq/kg in Garra lamta, 0.29 +/-0.02 Bq/kg in Neolissocheilus hexaganolepis, and 3.3 +/-0.1 Bq/kg in Macrobrachium sp. is observed. Activity concentration in plant samples was analyzed and the activity ranges from 0.020 +/-0.002 to 9.69 +/-0.35 Bq/kg. Committed effective dose by the adult population of the Domiasiat area through intake of (210)Po through these food items was also determined and compared with the Indian average value and the worldwide average value.

  3. Emission of polycyclic aromatic hydrocarbons and lead during Chinese mid-autumn festival.

    PubMed

    Kuo, Chung-Yih; Lee, Hong-Shen; Lai, Jeang-Hung

    2006-07-31

    The emission factors of total particulate polycyclic aromatic hydrocarbons (PAHs), Benzo(a)pyrene (BaP), BaP-equivalent doses (BaP(eq)) and Pb for burning three kinds of charcoal were investigated in this study: fast-lighting charcoal, Taiwanese, and Indonesian charcoal (the latter two of which are not fast-lighting). Compared to the burning of Taiwanese and Indonesian charcoal, the burning of fast-lighting charcoal can emit much larger amounts of total PAHs, BaP(eq) and Pb into the atmosphere. The emission factors of total PAHs, BaP and BaP(eq) for broiling meat were noticeably higher than those for broiling vegetables and non-fish seafood. When using Indonesian charcoal to broil meat, the total emission factors of particulate PAHs and BaP were about 15.7 and 0.39 mg/kg, respectively. The total amounts of particulate PAHs and Pb emitted from cookouts during Mid-Autumn Festival were 2881 and 120 g, respectively. Total PAHs and BaP(eq) in PM(10) aerosols on Mid-Autumn Festival nights increased about 1.6 and 1.5 times, respectively, higher than those on non-festival nights. The mean concentration of Pb on the nights of Mid-Autumn Festival increases to about 2.8 times that of non-festival nights.

  4. Effect of a new functional CYP3A4 polymorphism on calcineurin inhibitors' dose requirements and trough blood levels in stable renal transplant patients.

    PubMed

    Elens, Laure; van Schaik, Ron H; Panin, Nadtha; de Meyer, Martine; Wallemacq, Pierre; Lison, Dominique; Mourad, Michel; Haufroid, Vincent

    2011-10-01

    CYP3A4 is involved in the oxidative metabolism of many drugs and xenobiotics including the immunosuppressants tacrolimus (Tac) and cyclosporine (CsA). The objective of the study was to assess the potential influence of a new functional SNP in CYP3A4 on the pharmacokinetic parameters assessed by dose requirements and trough blood levels of both calcineurin inhibitors (CNI) in stable renal transplant patients. A total of 99 stable renal transplant patients receiving either Tac (n = 49) or CsA (n = 50) were genotyped for the CYP3A4 intron 6 C>T (rs35599367) and CYP3A5*3 SNPs. Trough blood levels ([Tac](0) or [CsA](0) in ng/ml), dose-adjusted [Tac](0) or [CsA](0) (ng/ml per mg/kg bodyweight) as well as doses (mg/kg bodyweight) required to achieve target concentrations were compared among patients according to allelic status for CYP3A4 and CYP3A5. Dose-adjusted concentrations were 2.0- and 1.6-fold higher in T-variant allele carriers for the CYP3A4 intron 6 C>T SNP compared with homozygous CC for Tac and CsA, respectively. When CYP3A4/CYP3A5 genotypes were combined, the difference was even more striking as the so-defined CYP3A poor metabolizer group presented dose-adjusted concentration 1.6- and 4.1-fold higher for Tac, and 1.5- and 2.2-fold higher for CsA than the intermediate metabolizer and extensive metabolizer groups, respectively. Multiple linear regression analysis revealed that, taken together, both CYP3A4 intron 6 and CYP3A5*3 SNPs explained more than 60 and 20% of the variability observed in dose-adjusted [Tac](0) and [CsA](0), respectively. The CYP3A4 intron 6 C>T polymorphism is associated with altered Tac and CsA metabolism. CYP3A4 intron 6 C>T along with CYP3A5*3 (especially for Tac) pharmacogenetic testing performed just before transplantation may help identifying patients at risk of CNI overexposure and contribute to limit CNI-related nephrotoxicity by refining the starting dose according to their genotype. Original submitted 5 May 2011; Revision submitted 29 June 2011.

  5. Testing and Qualifying Linear Integrated Circuits for Radiation Degradation in Space

    NASA Technical Reports Server (NTRS)

    Johnston, Allan H.; Rax, Bernard G.

    2006-01-01

    This paper discusses mechanisms and circuit-related factors that affect the degradation of linear integrated circuits from radiation in space. For some circuits there is sufficient degradation to affect performance at total dose levels below 4 krad(Si) because the circuit design techniques require higher gain for the pnp transistors that are the most sensitive to radiation. Qualification methods are recommended that include displacement damage as well as ionization damage.

  6. Continuing evaluation of bipolar linear devices for total dose bias dependency and ELDRS effects

    NASA Technical Reports Server (NTRS)

    McClure, Steven S.; Gorelick, Jerry L.; Yui, Candice; Rax, Bernard G.; Wiedeman, Michael D.

    2003-01-01

    We present results of continuing efforts to evaluate total dose bias dependency and ELDRS effects in bipolar linear microcircuits. Several devices were evaluated, each exhibiting moderate to significant bias and/or dose rate dependency.

  7. Methyl bromide as a quarantine treatment for Chlorophorus annularis (Coleoptera: Cerambycidae) in raw bamboo poles.

    PubMed

    Barak, Alan V; Weidong, Yang; Daojian, Yu; Yi, Jiao; Lin, Kang; Zhilin, Chen; Xingyuan, Ling; Guoping, Zhan

    2009-06-01

    At least 26 different species of insects of quarantine significance were intercepted from 1985 to 2005 on bamboo (Bambusa spp.) garden stakes from China. Three fifths of the live insects were cerambycids in nine genera, including Chlorophorus annularis F., the bamboo borer. The current APHIS-PPQ treatment is fumigation schedule T404-d, which requires high doses of methyl bromide (MeBr) for 24 h. No specific fumigation data exist for C. annularis. Chinese and American quarantine scientists cooperated in testing to determine whether this schedule, or lower doses, would be effective as a quarantine treatment for C. annularis infesting dried bamboo poles. A lower dose based on APHIS tests for solid wood packing (SWP) failed (3/511 survivors) at 56 g/m3 for 24 h at 10.0 degrees C. We therefore tested five progressive doses at five temperatures intermediate between the lower SWP schedule and the much higher applied doses (e.g., 120 g/m3 for 24 h at 10.0 degrees C) of schedule T404-d. Fumigations of infested bamboo poles conducted in 403.2-liter chambers with 52% vol:vol loading at doses of 48, 64, 80, 96, and 112 g/m3 at 26.7, 21.1, 15.6, 10.0, and 4.4 degrees C, respectively (20 total replicates, with 4 replicates per dose), had no survivors among 2,847 larvae, 140 pupae, and 122 adults. Control replicates (three) had a total of 455 live stages (397 larvae, 31 pupae, and 27 adults). Tests conducted with a sea/land cargo container loaded to 80% capacity with bamboo poles verified the ability of the schedule to maintain effective concentrations over 24 h in commercial-sized fumigations. We propose a new bamboo quarantine treatment schedule at reduced rates of applied MeBr.

  8. Dose-Effect Relationships for Adverse Events After Cranial Radiation Therapy in Long-term Childhood Cancer Survivors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dijk, Irma W.E.M. van, E-mail: i.w.vandijk@amc.uva.nl; Cardous-Ubbink, Mathilde C.; Pal, Helena J.H. van der

    Purpose: To evaluate the prevalence and severity of clinical adverse events (AEs) and treatment-related risk factors in childhood cancer survivors treated with cranial radiation therapy (CRT), with the aim of assessing dose-effect relationships. Methods and Materials: The retrospective study cohort consisted of 1362 Dutch childhood cancer survivors, of whom 285 were treated with CRT delivered as brain irradiation (BI), as part of craniospinal irradiation (CSI), and as total body irradiation (TBI). Individual CRT doses were converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Survivors had received their diagnoses between 1966 and 1996 and survived at least 5 yearsmore » after diagnosis. A complete inventory of Common Terminology Criteria for Adverse Events grade 3.0 AEs was available from our hospital-based late-effect follow-up program. We used multivariable logistic and Cox regression analyses to examine the EQD{sub 2} in relation to the prevalence and severity of AEs, correcting for sex, age at diagnosis, follow-up time, and the treatment-related risk factors surgery and chemotherapy. Results: There was a high prevalence of AEs in the CRT group; over 80% of survivors had more than 1 AE, and almost half had at least 5 AEs, both representing significant increases in number of AEs compared with survivors not treated with CRT. Additionally, the proportion of severe, life-threatening, or disabling AEs was significantly higher in the CRT group. The most frequent AEs were alopecia and cognitive, endocrine, metabolic, and neurologic events. Using the EQD{sub 2}, we found significant dose-effect relationships for these and other AEs. Conclusion: Our results confirm that CRT increases the prevalence and severity of AEs in childhood cancer survivors. Furthermore, analyzing dose-effect relationships with the cumulative EQD{sub 2} instead of total physical dose connects the knowledge from radiation therapy and radiobiology with the clinical experience.« less

  9. Intensity Modulated Radiotherapy Improves Target Coverage and Parotid Gland Sparing When Delivering Total Mucosal Irradiation in Patients With Squamous Cell Carcinoma of Head and Neck of Unknown Primary Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhide, Shreerang; Clark, Catherine; Harrington, Kevin

    2007-10-01

    Head and neck squamous cell carcinoma with occult primary site represents a controversial clinical problem. Conventional total mucosal irradiation (TMI) maximizes local control, but at the expense of xerostomia. IMRT has been shown to spare salivary tissue in head and cancer patients. This study has been performed to investigate the potential of IMRT to perform nodal and TMI and also allow parotid gland sparing in this patient group. Conventional radiotherapy (CRT) and IMRT plans were produced for six patients to treat the ipsilateral (involved) post-operative neck (PTV1) and the un-operated contralateral neck and mucosal axis (PTV2). Plans were produced withmore » and without the inclusion of nasopharynx in the PTV2. The potential to improve target coverage and spare the parotid glands was investigated for the IMRT plans. There was no significant difference in the mean doses to the PTV1 using CRT and IMRT (59.7 and 60.0 respectively, p = 0.5). The maximum doses to PTV1 and PTV2 were lower for the IMRT technique as compared to CRT (P = 0.008 and P < 0.0001), respectively, and the minimum doses to PTV1 and PTV2 were significantly higher for IMRT as compared to CRT (P = 0.001 and P = 0.001), respectively, illustrating better dose homogeneity with IMRT. The mean dose to the parotid gland contralateral to PTV1 was significantly lower for IMRT (23.21 {+-} 0.7) as compared to CRT (50.5 {+-} 5.8) (P < 0.0001). There was a significant difference in parotid dose between plans with and without the inclusion of the nasopharynx. IMRT offers improved dose homogeneity in PTV1 and PTV2 and allows for parotid sparing.« less

  10. Differential effects of low and high dose folic acid on endothelial dysfunction in a murine model of mild hyperhomocysteinaemia.

    PubMed

    Clarke, Zoe L; Moat, Stuart J; Miller, Alastair L; Randall, Michael D; Lewis, Malcolm J; Lang, Derek

    2006-12-03

    The exact mechanism(s) by which hyperhomocysteinaemia promotes vascular disease remains unclear. Moreover, recent evidence suggests that the beneficial effect of folic acid on endothelial function is independent of homocysteine-lowering. In the present study the effect of a low (400 microg/70 kg/day) and high (5 mg/70 kg/day) dose folic acid supplement on endothelium-dependent relaxation in the isolated perfused mesenteric bed of heterozygous cystathionine beta-synthase deficient mice was investigated. Elevated total plasma homocysteine and impaired relaxation responses to methacholine were observed in heterozygous mice. In the presence of N(G)-nitro-L-arginine methyl ester relaxation responses in wild-type tissues were reduced, but in heterozygous tissues were abolished. Clotrimazole and 18alpha-glycyrrhetinic acid, both inhibitors of non-nitric oxide/non-prostanoid-induced endothelium-dependent relaxation, reduced responses to methacholine in wild-type but not heterozygous tissues. The combination of N(G)-nitro-L-arginine methyl ester and either clotrimazole or 18alpha-glycyrrhetinic acid completely inhibited relaxation responses in wild-type tissues. Both low and high dose folic acid increased plasma folate, reduced total plasma homocysteine and reversed endothelial dysfunction in heterozygous mice. A greater increase in plasma folate in the high dose group was accompanied by a more significant effect on endothelial function. In the presence of N(G)-nitro-L-arginine methyl ester, a significant residual relaxation response was evident in tissues from low and high dose folic acid treated heterozygous mice. These data suggest that the impaired mesenteric relaxation in heterozygous mice is largely due to loss of the non-nitric oxide/non-prostanoid component. While low dose folic acid may restore this response in a homocysteine-dependent manner, the higher dose has an additional effect on nitric oxide-mediated relaxation that would appear to be independent of homocysteine lowering.

  11. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography

    PubMed Central

    Zappala, Susan; Helliwell, Jonathan R.; Tracy, Saoirse R.; Mairhofer, Stefan; Sturrock, Craig J.; Pridmore, Tony; Bennett, Malcolm; Mooney, Sacha J.

    2013-01-01

    X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored. PMID:23840640

  12. SU-E-T-216: Comparison of Volumetrically Modulated Arc Therapy Treatment Using Flattening Filter Free Beams Vs. Flattened Beams for Partial Brain Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, S; Roa, D; Hanna, N

    2015-06-15

    Purpose: Flattening Filter Free (FFF) beams offer the potential for higher dose rates, short treatment time, and lower out of field dose. Therefore, the aim of this study was to investigate the dosimetric effects and out of field dose of Volumetric Modulated Arc Therapy (VMAT) plans using FFF vs Flattening Filtering (FF) beams for partial brain irradiation. Methods: Ten brain patients treated with a 6FF beam from a Truebeam STX were analyzed retrospectively for this study. These plans (46Gy at 2 Gy per fraction) were re-optimized for 6FFF beams using the same dose constraints as the original plans. PTV coverage,more » PTV Dmax, total MUs, and mean dose to organs-at-risk (OAR) were evaluated. In addition, the out-of-field dose for 6FF and 6FFF plans for one patient was measured on an anthropomorphic phantom. TLDs were placed inside (central axis) and outside (surface) the phantom at distances ranging from 0.5 cm to 17 cm from the field edge. Paired T-test was used for statistical analysis. Results: PTV coverage and PTV Dmax were comparable for the FF and FFF plans with 95.9% versus 95.6% and 111.2% versus 111.9%, respectively. Mean dose to the OARs were 3.7% less for FFF than FF plans (p<0.0001). Total MUs were, on average, 12.5% greater for FFF than FF plans with 481±55 MU (FFF) versus 429±50 MU (FF), p=0.0003. On average, the measured out of field dose was 24% less for FFF compared to FF, p<0.0001. A similar beam-on time was observed for the FFF and FF treatment. Conclusion: It is beneficial to use 6FFF beams for regular fractionated brain VMAT treatments. VMAT treatment plans using FFF beams can achieve comparable PTV coverage but with more OAR sparing. The out of field dose is significant less with mean reduction of 24%.« less

  13. Effects of aspirin and enoxaparin in a rat model of liver fibrosis.

    PubMed

    Li, Chen-Jie; Yang, Zhi-Hui; Shi, Xiao-Liu; Liu, De-Liang

    2017-09-21

    To examine the effects of aspirin and enoxaparin on liver function, coagulation index and histopathology in a rat model of liver fibrosis. METHODS Forty-five male Sprague-Dawley rats were randomly divided into the control group (n = 5) and model group (n = 40). Thioacetamide (TAA) was used to induce liver fibrosis in the model group. TAA-induced fibrotic rats received TAA continuously (n = 9), TAA + low-dose aspirin (n = 9), TAA + high-dose aspirin (n = 9) or TAA + enoxaparin (n = 9) for 4 wk. All rats were euthanized after 4 wk, and both hematoxylin-eosin and Masson staining were performed to observe pathological changes in liver tissue. Liver fibrosis was assessed according to the METAVIR score. Compared with untreated cirrhotic controls, a significant improvement in fibrosis grade was observed in the low-dose aspirin, high-dose aspirin and enoxaparin treated groups, especially in the high-dose aspirin treated group. Alanine aminotransferase and total bilirubin were higher, albumin was lower and both prothrombin time and international normalized ratio were prolonged in the four treatment groups compared to controls. No significant differences among the four groups were observed. Aspirin and enoxaparin can alleviate liver fibrosis in this rat model.

  14. Inflammatory subtypes in cough-variant asthma: association with maintenance doses of inhaled corticosteroids.

    PubMed

    Matsuoka, Hirofumi; Niimi, Akio; Matsumoto, Hisako; Takemura, Masaya; Ueda, Tetsuya; Yamaguchi, Masafumi; Jinnai, Makiko; Inoue, Hideki; Ito, Isao; Chin, Kazuo; Mishima, Michiaki

    2010-12-01

    Sputum cell-subtype profiles in cough-variant asthma (CVA) are unknown. Ninety-eight inhaled corticosteroid (ICS)-naive CVA patients were classified according to sputum eosinophil (eos)/neutrophil (neu) counts, as reported in subjects with asthma, as eosinophilic (E) (eos ≥ 1.0%, neu < 61%; n = 28), neutrophilic (N) (eos < 1.0%, neu ≥ 61%; n = 31), mixed granulocytic (M) (eos ≥ 1.0%, neu ≥ 61%; n = 12), and paucigranulocytic (P) (eos < 1.0%, neu < 61%; n = 27) subtypes. Patient characteristics; sputum levels of eosinophil cationic protein (ECP), IL-8, and neutrophil elastase (NE); and daily ICS doses required to maintain control during follow-up (6, 12, 18, and 24 months) were compared, retrospectively. Subtype N patients, predominantly women, were marginally older than the other subtypes, but FEV(1), airway responsiveness, and total and specific IgE results did not differ. ECP levels were higher in M and E than in N and P subtypes, being similar between M and E or N and P subtypes. Levels of IL-8 and NE were higher in M than in other subtypes, being similar among the latter. ICS doses were initially similar in all subtypes (800 μg equivalent of beclomethasone) but were higher in M than in N and P subtypes throughout follow-up, with E being intermediate between M and N or P subtypes. ICS doses decreased (halved or quartered) in E, N, and P patients followed for 24 months (P < .0001 for all) but remained unchanged in M subjects. IL-8 and NE levels correlated positively with ECP levels. In addition to eosinophils, neutrophils, which are possibly activated in the presence of eosinophils, may participate in the pathophysiology of CVA.

  15. Clinical features and prognostic factors in patients with bone metastases from hepatocellular carcinoma receiving external beam radiotherapy.

    PubMed

    He, Jian; Zeng, Zhao-Chong; Tang, Zhao-You; Fan, Jia; Zhou, Jian; Zeng, Meng-Su; Wang, Jian-Hua; Sun, Jing; Chen, Bing; Yang, Ping; Pan, Bai-Sheng

    2009-06-15

    The current study was performed to identify clinical features and independent predictors of survival in patients with bone metastases from hepatocellular carcinoma (HCC). Patients (n = 205) with bone metastases from HCC received external beam radiotherapy (EBRT) between 1997 and 2007. Demographic variables, laboratory values, tumor characteristics, and treatment modalities were determined before EBRT. The total radiation dose ranged from 32 to 66 grays (Gy) (median, 50 Gy) and was focused on the involved bone. In 80 of 205 (39.0%) patients with bone metastasis from HCC, tumors were characterized by osteolytic, expansile soft-tissue masses. Overall pain relief from EBRT occurred in 204 patients (99.5%). No consistent dose-response relation was found for palliation of bone metastases with doses between 32 and 66 Gy (P = .068), but the retreatment rate was higher in patients with expansile soft tissue. On univariate analysis, shorter survival was associated with poorer Karnofsky performance status (KPS), higher gamma-glutamyltransferase and alpha-fetoprotein levels, tumor size >5 cm, uncontrolled intrahepatic tumors, multifocal bone lesions, involvement of spinal vertebrae, extraosseous metastases, and a shorter disease-free interval after an initial diagnosis of HCC. On multivariate analysis, pretreatment-unfavorable predictors were associated with lower KPS, higher tumor markers, and uncontrolled intrahepatic tumor when KPS was considered. The median survival was 7.4 months. The results of the current study provide detailed information regarding clinical features, survival outcomes, and prognostic factors for HCC with bone metastases in a relatively large cohort of patients treated with EBRT. These prognostic factors will help in determining which dose and fraction are appropriate. (c) 2009 American Cancer Society.

  16. Variation in treatment strategies of Swiss general practitioners for subclinical hypothyroidism in older adults.

    PubMed

    Baumgartner, Christine; den Elzen, Wendy P J; Blum, Manuel R; Coslovsky, Michael; Streit, Sven; Frey, Peter; Herzig, Lilli; Haller, Dagmar M; Mooijaart, Simon P; Bischoff, Thomas; Rosemann, Thomas; Gussekloo, Jacobijn; Rodondi, Nicolas

    2015-01-01

    As the best management of subclinical hypothyroidism is controversial, we aimed to assess variations in treatment strategies depending on different Swiss regions, physician and patient characteristics. We performed a case-based survey among general practitioners (GPs) in different Swiss regions, which consisted of eight hypothetical cases presenting a female patient with subclinical hypothyroidism and nonspecific complaints differing by age, vitality status and thyroid-stimulating hormone (TSH) concentration. A total of 262 GPs participated in the survey. There was considerable variation in the levothyroxine starting dose chosen by GPs, ranging from 25 µg to 100 µg. Across the Swiss regions, GPs in the Bern region were significantly more inclined to treat, with a higher probability of initiating treatment (60%, p = 0.01) and higher mean starting doses (45 µg, p <0.01) compared with the French-speaking region (44%, 36 µg); the Zurich region had intermediate values (52%, 39 µg). We found no association between treatment rate and other physician characteristics. GPs were more reluctant to initiate treatment in 85-year-old than in 70-year-old women (odds ratio [OR] 0.77, 95% confidence interval [CI] 0.63-0.94), and more likely to treat women with a TSH of 15 mU/l than those with a TSH of 6mU/l (OR 8.71, 95% CI 6.21-12.20). There are strong variations in treatment strategies for elderly patients with subclinical hypothyroidism across different Swiss regions, including use of higher starting doses than the recommended 25 µg in the Swiss guidelines, which recommend a starting dose of 25 µg. These variations likely reflect the current uncertainty about the benefits of treatment, which arise from the current lack of evidence from adequately powered clinical trials.

  17. [Estimated glucose disposal rate in patients under 18 years of age with type 1 diabetes mellitus and overweight or obesity].

    PubMed

    Palomo Atance, Enrique; Ballester Herrera, M José; Giralt Muiña, Patricio; Ruiz Cano, Rafael; León Martín, Alberto; Giralt Muiña, Juan

    2013-01-01

    To assess the estimated glucose disposal rate (eGDR), insulin dose, and lipoprotein profile in children with type 1 diabetes mellitus (T1DM) and overweight or obesity as compared to children with T1DM and normal weight. A total of 115 patients (aged 5-16 years) with T1DM on intensive insulin therapy were recruited. The following parameters were measured: weight, height, body mass index, waist and hip circumference, insulin dose, eGDR, glycosylated hemoglobin, blood pressure, and lipoprotein profile. Results were stratified by sex and age. No significant differences were found in eGDR between children with normal weight, overweight, and obesity. However, obese children older than 11 years had lower eGDR values (9.3±1.3 vs 10.1±0.8 mg kg(-1)min(-1); p<0.01). Insulin dose was higher in overweight and obese children, especially in IU/m2/day (37.7 vs 36.1 vs. 29.4 respectively; p<0.01). Obese children had higher low-density lipoprotein cholesterol levels than children with overweight and normal weight (106.5 vs 91.7 vs 91.5mg/dL respectively; p<0.01). No correlation was found between waist circumference and the different markers of insulin resistance. Values of eGDR values were lower in obese children with T1DM older than 11 years, and this may therefore be considered a marker of insulin resistance. Insulin dose was higher in diabetic patients with overweight or obesity, specially in IU/m2/day. Obese children with T1DM had a lipoprotein profile of cardiovascular risk. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.

  18. Low-dose factor VIII infusion in Chinese adult haemophilia A patients: pharmacokinetics evidence that daily infusion results in higher trough level than with every-other-day infusion with similar factor VIII consumption.

    PubMed

    Hua, B; Lee, A; Fan, L; Li, K; Zhang, Y; Poon, M-C; Zhao, Y

    2017-05-01

    Pharmacokinetics (PK) modelling suggests improvement of trough levels are achieved by using more frequent infusion strategy. However, no clinical study data exists to confirm or quantify improvement in trough level, particularly for low-dose prophylaxis in patients with haemophilia A. To provide evidence that low dose daily (ED) prophylaxis can increase trough levels without increasing FVIII consumption compared to every-other-day (EOD) infusion. A cross-over study on 5 IU kg -1 FVIII daily vs. 10 IU kg -1 EOD infusions, each for 14 days was conducted at the PUMCH-HTC. On the ED schedule, trough (immediate prior to infusion), and peak FVIII:C levels (30 min after infusion) were measured on days 1-5; and trough levels alone on days 7, 9, 11 and 13. For the EOD schedule, troughs, peaks and 4-h postinfusion were measured on day 1; troughs and peaks on days 3, 5, and 7; troughs alone on days 9, 11 and 13 and 24-h postinfusion on days 2, 4 and 6. FVIII inhibitors were assessed on days 0 and 14 during both infusion schedules. Six patients were enrolled. PK evidence showed that daily prophylaxis achieved higher (~2 times) steady-state FVIII trough levels compared to EOD with the same total factor consumption. The daily prophylaxis had good acceptability among patients and reduced chronic pain in the joints in some patients. Our PK study shows low-dose factor VIII daily infusion results in higher trough level than with EOD infusion with similar factor VIII consumption in Chinese adult haemophilia A patients. © 2017 John Wiley & Sons Ltd.

  19. Patterns of opioid use in sickle cell disease.

    PubMed

    Han, Jin; Saraf, Santosh L; Zhang, Xu; Gowhari, Michel; Molokie, Robert E; Hassan, Joharah; Alhandalous, Chaher; Jain, Shivi; Younge, Jewel; Abbasi, Taimur; Machado, Roberto F; Gordeuk, Victor R

    2016-11-01

    Pain, the hallmark complication of sickle cell disease (SCD), is largely managed with opioid analgesics in the United States, but comprehensive data regarding the long-term use of opioids in this patient population is lacking. The pain medication prescription records from a cohort of 203 SCD patients were analyzed. Twenty-five percent were not prescribed opioid medications while 47% took only short-acting opioids, 1% took only long-acting opioids, and 27% took a combination of short-acting and long-acting opioids. The median (interquartile range) daily opioid dose was 6.1 mg (1.7-26.3 mg) of oral morphine equivalents, which is lower than the published opioid use among patients with other pain syndromes. The dose of opioids correlated with the number of admissions due to vaso-occlusive crisis (VOC) (r = 0.53, P < 0.001). When the patients were grouped into quartiles based on daily dose opioid use, a logistic regression model showed that history of avascular necrosis (AVN) (OR: 2.87, 95% CI: 1.37-6.02, P = 0.005), 25-OHD levels (OR: 0.59, 95% CI: 0.38-0.93, P = 0.024) and total bilirubin concentration (OR: 0.64, 95% CI: 0.42-0.99, P = 0.043) were independently associated with opioid use quartiles. In conclusion, doses and types of opioid medications used by adult SCD patients vary widely. Our findings implicate AVN and lower vitamin D levels as factors associated with higher opioid use. They also suggest an association of higher bilirubin levels, possibly suggesting higher hemolytic rate, with lower opioid use. Am. J. Hematol. 91:1102-1106, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. The Effectiveness of the Rectal Administration of Low-dose Diclofenac for the Prevention of Post-endoscopic Retrograde Cholangiopancreatography Pancreatitis.

    PubMed

    Okuno, Mitsuru; Shiroko, Junko; Taguchi, Daisuke; Yamaguchi, Kimihiro; Takada, Jun; Imai, Susumu; Sato, Hiroyuki; Thanabashi, Shinobu

    2018-03-30

    Objective A 50-100-mg rectal dose of nonsteroidal anti-inflammatory drugs (NSAIDs; diclofenac or indomethacin) has been shown to prevent post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP). However, this is higher than the recommended 25-mg dose that is commonly administered to Japanese patients. The objective of this study was to evaluate the safety and efficacy of 25-mg rectal dose of diclofenac in preventing PEP. Methods Between January 2016 and March 2017, a total of 147 patients underwent ERCP with or without the rectal administration of diclofenac (25 mg) 20 min before the procedure. A retrospective analysis was conducted to evaluate the efficacy and safety of this dose in preventing PEP. Results Thirteen patients (8.8%) developed PEP: 3 patients (4.1%) in the diclofenac group and 10 (13.7%) in the control group (p=0.0460). After ERCP, there were no cases of gastrointestinal hemorrhage, ulceration, acute renal failure, or death. A multivariate logistic regression analysis revealed that the non-administration of rectal diclofenac was a risk factor for PEP (odds ratio=3.530; 95% confidence interval=1.017-16.35; p=0.0468). Conclusions A 25-mg rectal dose of diclofenac might prevent PEP.

Top