Sample records for highly oriented vo2

  1. VO2 nanoparticles on edge orientated graphene foam for high rate lithium ion batteries and supercapacitors

    NASA Astrophysics Data System (ADS)

    Ren, Guofeng; Zhang, Ruibo; Fan, Zhaoyang

    2018-05-01

    With the fully exposed graphene edges, high conductivity and large surface area, edge oriented graphene foam (EOGF), prepared by deposition of perpendicular graphene network encircling the struts of Ni foam, is a superior scaffold to support active materials for electrochemical applications. With VO2 as an example, EOGF loaded VO2 nanoparticle (VO2/EOGF) electrode has high rate performance as cathode in lithium ion batteries (LIBs). In addition to the Li+ intercalation into the lattice, contribution of non-diffusion-limited pseudocapacitance to the capacity is prominent at high rates. VO2/EOGF based supercapacitor also exhibits fast response, with a characteristic frequency of 15 Hz when the phase angle reaches -45°, or a relaxation time constant of 66.7 ms. These results suggest the promising potential of EOGF as a scaffold in supporting active nanomaterials for electrochemical energy storage and other applications.

  2. Spectroscopic analysis of phase constitution of high quality VO2 thin film prepared by facile sol-gel method

    NASA Astrophysics Data System (ADS)

    Wu, Y. F.; Fan, L. L.; Chen, S. M.; Chen, S.; Zou, C. W.; Wu, Z. Y.

    2013-04-01

    VO2 thin films with large-area were prepared on Al2O3 substrates by a simple sol-gel method. After an annealing treatment under low vacuum condition, all the VO2 films showed a preferred growth direction and exhibited excellent semiconductor-metal transition (SMT) characteristics. The structure and electrical properties of the obtained VO2 films were investigated systematically. Raman spectra, X-ray diffraction and X-ray absorption spectra measurements pointed out that the VO2 film on Al_2 O_3 ( {10overline 1 0}) substrate showed a M1 phase instead of M2 phase as reported in previous studies. Based on the experiment results, it was suggested that the strained structure of oriented VO2 films could be a mechanism for the formation of the intermediate M2 phase, whereas it is difficult to access the pure M2 phase of undoped VO2 films. VO2 film on Al_2 O_3 ( {10overline 1 0} ) substrate showed a lower SMT temperature compared to VO2 film on Al2O3 (0001), which can be mostly attributed to the differences of both lattice mismatch and thermal stress. The present results confirm and make clear the relevance of the substrate orientation in the growth of VO2 film and their different contributions to the SMT characteristics in vanadate systems.

  3. Study on Thermochromic VO2 Films Grown on ZnO-Coated Glass Substrates for “Smart Windows”

    NASA Astrophysics Data System (ADS)

    Kato, Kazuhiro; Song, Pung Keun; Odaka, Hidehumi; Shigesato, Yuzo

    2003-10-01

    Vanadium dioxide (VO2) is one of the most attractive thermochromic materials, which show large changes in optical and electrical properties at the transition temperature (Tt) close to the atmospheric temperature (approximately 340 K). We already reported for VO2 deposition by rf magnetron sputtering using V2O3 or V2O5 targets that VO2 films thicker than 400 nm showed high thermochromic performance, whereas the VO2 films thinner than 200 nm did not show such performance because of their poor crystallinity and off-stoichiometry. In this study, very thin thermochromic VO2 films with thicknesses of about 50 nm were successfully deposited using highly < 001>-preferred oriented ZnO polycrystalline films as a buffer layer between the VO2 film and glass substrate (VO2/ZnO/glass) because of the heteroepitaxial growth of VO2 polycrystalline films. W-doped VO2 films were also deposited on the ZnO-coated glass substrates (ZnO/glass) by cosputtering. It was confirmed that W doping for thin VO2 films deposited on the ZnO/glass can decrease Tt systematically. Such very thin VO2 films should have high potential for application in “smart windows”.

  4. Influence of Discharge Current on Phase Transition Properties of High Quality Polycrystalline VO2 Thin Film Fabricated by HiPIMS

    PubMed Central

    Lin, Tiegui; Wang, Jian; Liu, Gang; Wang, Langping; Wang, Xiaofeng; Zhang, Yufen

    2017-01-01

    To fabricate high-quality polycrystalline VO2 thin film with a metal–insulator transition (MIT) temperature less than 50 °C, high-power impulse magnetron sputtering with different discharge currents was employed in this study. The as-deposited VO2 films were characterized by a four-point probe resistivity measurement system, visible-near infrared (IR) transmittance spectra, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy. The resistivity results revealed that all the as-deposited films had a high resistance change in the phase transition process, and the MIT temperature decreased with the increased discharge current, where little deterioration in the phase transition properties, such as the resistance and transmittance changes, could be found. Additionally, XRD patterns at various temperatures exhibited that some reverse deformations that existed in the MIT process of the VO2 film, with a large amount of preferred crystalline orientations. The decrease of the MIT temperature with little deterioration on phase transition properties could be attributed to the reduction of the preferred grain orientations. PMID:28772990

  5. Metal-insulator transition of valence-controlled VO2 thin film prepared by RF magnetron sputtering using oxygen radical

    NASA Astrophysics Data System (ADS)

    Suetsugu, Takaaki; Shimazu, Yuichi; Tsuchiya, Takashi; Kobayashi, Masaki; Minohara, Makoto; Sakai, Enju; Horiba, Koji; Kumigashira, Hiroshi; Higuchi, Tohru

    2016-06-01

    We have prepared b-axis-oriented VO2 thin films by RF magnetron sputtering using oxygen radicals as the reactive gas. The VO2 thin films consist of a mixed-valence V3+/V4+ state formed by oxygen vacancies. The V3+ ratio strongly depends on the film thickness and the oxygen partial pressure of the radical gun during deposition. The lattice constant of the b-axis increases and the metal-insulator transition (MIT) temperature decreases with decreasing V3+ ratio, although the VO2 thin films with a high V3+ ratio of 42% do not exhibit MIT. The bandwidths and spectral weights of V 3d a1g and \\text{e}\\text{g}σ bands at around the Fermi level, which correspond to the insulating phase at 300 K, are smaller in the VO2 thin films with a low V3+ ratio. These results indicate that the control of the mixed-valence V3+/V4+ state is important for the MIT of b-axis-oriented VO2 thin films.

  6. The effect of Argon pressure dependent V thin film on the phase transition process of (020) VO2 thin film

    NASA Astrophysics Data System (ADS)

    Meng, Yifan; Huang, Kang; Tang, Zhou; Xu, Xiaofeng; Tan, Zhiyong; Liu, Qian; Wang, Chunrui; Wu, Binhe; Wang, Chang; Cao, Juncheng

    2018-01-01

    It has been proved challenging to fabricate the single crystal orientation of VO2 thin film by a simple method. Based on chemical reaction thermodynamic and crystallization analysis theory, combined with our experimental results, we find out that when stoichiometric number of metallic V in the chemical equation is the same, the ratio of metallic V thin film surface average roughness Ra to thin film average particle diameter d decreases with the decreasing sputtering Argon pressure. Meanwhile, the oxidation reaction equilibrium constant K also decreases, which will lead to the increases of oxidation time, thereby the crystal orientation of the VO2 thin film will also become more uniform. By sputtering oxidation coupling method, metallic V thin film is deposited on c-sapphire substrate at 1 × 10-1 Pa, and then oxidized in the air with the maximum oxidation time of 65s, high oriented (020) VO2 thin film has been fabricated successfully, which exhibits ∼4.6 orders sheet resistance change across the metal-insulator transition.

  7. Growth and study of first order metal insulator transition in VO2 films

    NASA Astrophysics Data System (ADS)

    Rathore, Ajay K.; Kumar, Satish; Kumar, Dhirendra; Sathe, V. G.

    2015-06-01

    VO2 films have been grown on Si substrate using pulse laser deposition technique. The as-deposited film prepared by V2O3 target is found to possess signatures of V2O5 phase. Up on annealing at 780°C the film transforms to VO2 phase. The annealed film is found to be highly oriented along (011) and single phase in nature. The high temperature Raman spectroscopic measurements on the annealed film showed first order transition from monoclinic insulating phase to conductive tetragonal rutile phase around 65°C.

  8. Enhanced electrochemical performance of orientated VO2(B) raft-like nanobelt arrays through direct lithiation for lithium ion batteries.

    PubMed

    Liu, Liang; Liu, Qiang; Zhao, Wen; Li, Guochun; Wang, Limei; Shi, Weidong; Chen, Long

    2017-02-10

    Lithiation modification of VO 2 (B) has been carried out by a facile hydrothermal process, and the compact and locally ordered VO 2 (B) raft-like nanobelt arrays have been prepared. The synthesis route provides a new approach to elaborate a VO 2 (B) nanostructure under a mild environment condition. It is found that the growth mechanism of VO 2 (B) raft-like nanobelt arrays is different from the traditional nucleation-growth process. A novel chemical lithiating-exfoliating-splitting model is proposed. Compared with the bulk counterpart, the lithiated VO 2 (B) raft-like nanobelt arrays as cathodes exhibit a higher discharge capacity and an enhanced high-rate performance owing to their increased structural anisotropy and decreased polarization. This work indicates that VO 2 (B) raft-like nanobelt arrays have great potential applications as cathode materials for lithium ion batteries.

  9. Enhanced electrochemical performance of orientated VO2(B) raft-like nanobelt arrays through direct lithiation for lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Liu, Liang; Liu, Qiang; Zhao, Wen; Li, Guochun; Wang, Limei; Shi, Weidong; Chen, Long

    2017-02-01

    Lithiation modification of VO2(B) has been carried out by a facile hydrothermal process, and the compact and locally ordered VO2(B) raft-like nanobelt arrays have been prepared. The synthesis route provides a new approach to elaborate a VO2(B) nanostructure under a mild environment condition. It is found that the growth mechanism of VO2(B) raft-like nanobelt arrays is different from the traditional nucleation-growth process. A novel chemical lithiating-exfoliating-splitting model is proposed. Compared with the bulk counterpart, the lithiated VO2(B) raft-like nanobelt arrays as cathodes exhibit a higher discharge capacity and an enhanced high-rate performance owing to their increased structural anisotropy and decreased polarization. This work indicates that VO2(B) raft-like nanobelt arrays have great potential applications as cathode materials for lithium ion batteries.

  10. Epitaxial stabilization and phase instability of VO2 polymorphs

    NASA Astrophysics Data System (ADS)

    Lee, Shinbuhm; Ivanov, Ilia N.; Keum, Jong K.; Lee, Ho Nyung

    2016-01-01

    The VO2 polymorphs, i.e., VO2(A), VO2(B), VO2(M1) and VO2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on various perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. Our successful epitaxy of both VO2(A) and VO2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO2 polymorphs for potential applications in advanced electronic and energy devices.

  11. Epitaxial stabilization and phase instability of VO2 polymorphs.

    PubMed

    Lee, Shinbuhm; Ivanov, Ilia N; Keum, Jong K; Lee, Ho Nyung

    2016-01-20

    The VO2 polymorphs, i.e., VO2(A), VO2(B), VO2(M1) and VO2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on various perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. Our successful epitaxy of both VO2(A) and VO2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO2 polymorphs for potential applications in advanced electronic and energy devices.

  12. Epitaxial stabilization and phase instability of VO2 polymorphs

    PubMed Central

    Lee, Shinbuhm; Ivanov, Ilia N.; Keum, Jong K.; Lee, Ho Nyung

    2016-01-01

    The VO2 polymorphs, i.e., VO2(A), VO2(B), VO2(M1) and VO2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on various perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. Our successful epitaxy of both VO2(A) and VO2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO2 polymorphs for potential applications in advanced electronic and energy devices. PMID:26787259

  13. Oxygen vacancy effects in HfO2-based resistive switching memory: First principle study

    NASA Astrophysics Data System (ADS)

    Dai, Yuehua; Pan, Zhiyong; Wang, Feifei; Li, Xiaofeng

    2016-08-01

    The work investigated the shape and orientation of oxygen vacancy clusters in HfO2-base resistive random access memory (ReRAM) by using the first-principle method based on the density functional theory. Firstly, the formation energy of different local Vo clusters was calculated in four established orientation systems. Then, the optimized orientation and charger conductor shape were identified by comparing the isosurface plots of partial charge density, formation energy, and the highest isosurface value of oxygen vacancy. The calculated results revealed that the [010] orientation was the optimal migration path of Vo, and the shape of system D4 was the best charge conductor in HfO2, which effectively influenced the SET voltage, formation voltage and the ON/OFF ratio of the device. Afterwards, the PDOS of Hf near Vo and total density of states of the system D4_010 were obtained, revealing the composition of charge conductor was oxygen vacancy instead of metal Hf. Furthermore, the migration barriers of the Vo hopping between neighboring unit cells were calculated along four different orientations. The motion was proved along [010] orientation. The optimal circulation path for Vo migration in the HfO2 super-cell was obtained.

  14. Matching characteristics of different buffer layers with VO2 thin films

    NASA Astrophysics Data System (ADS)

    Yang, Kai; Zhang, Dongping; Liu, Yi; Guan, Tianrui; Qin, Xiaonan; Zhong, Aihua; Cai, Xingmin; Fan, Ping; Lv, Weizhong

    2016-10-01

    VO2 thin films were fabricated by reactive DC magnetron sputtering on different buffer layers of MgF2, Al2O3 and TiO2, respectively. The crystallinity and orientation relationship, thickness of VO2 thin films, atoms vibrational modes, optical and electrical property, surface morphology of films were characterized by X-ray diffraction, Raman scattering microscopy, step profiler, spectrophotometer, four-probe technique, and scanning electron microscopy, respectively. XRD results investigated that the films have preferential crystalline planes VO2 (011). The crystallinity of VO2 films grown on TiO2 buffer layers are superior to VO2 directly deposited on soda-lime glass. The Raman bands of the VO2 films correspond to an Ag symmetry mode of VO2 (M). The sample prepared on 100nm TiO2 buffer layer appears nanorods structure, and exhibits remarkable solar energy modulation ability as high as 5.82% in full spectrum and 23% in near infrared spectrum. Cross-sectional SEM image of the thin films samples indicate that MgF2 buffer layer has clear interface with VO2 layer. But there are serious interdiffusion phenomenons between Al2O3, TiO2 buffer layer with VO2 layer.

  15. Influence of Nb doping on the phase transition properties of VO2 thin films prepared by ion beam co-sputtering deposition

    NASA Astrophysics Data System (ADS)

    Zhu, Huiqun; Li, Pengfei; Zhao, Lite; Liu, Jiahuan

    2016-03-01

    The Nb-doped VO2 thin films were successfully prepared on the glass substrates by ion beam co-sputtering at room temperature and post annealing under the air condition. The effects of the preparation processing and Nb doping on the thermal hysteresis loop and phase transition temperature of the VO2 thin films were analyzed by resistancetemperature measurement. The results show that Nb doping significantly changes the surface morphologies of VO2 thin films, and Nb-doped VO2 thin films exhibit VO2(002) preferred orientation growth with greatly improved crystallinity and orientation. Compared with pure VO2, the phase transition temperature of Nb-doped VO2 thin films drops to 40 ºC, and the width of thermal hysteresis loop narrows to 8 ºC. It is demonstrated that Nb-doped VO2 thin films prepared by ion beam co-sputtered at room temperature have an obvious thermal sensitive effect, and keep a good characteristic from metal to semiconductor phase transition.

  16. Epitaxial stabilization and phase instability of VO 2 polymorphs

    DOE PAGES

    Lee, Shinbuhm; Ivanov, Ilia N.; Keum, Jong K.; ...

    2016-01-20

    The VO 2 polymorphs, i.e., VO 2(A), VO 2(B), VO 2(M1) and VO 2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO 2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO 2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on variousmore » perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO 2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. In conclusion, our successful epitaxy of both VO 2(A) and VO 2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO 2 polymorphs for potential applications in advanced electronic and energy devices.« less

  17. Atomic Layer Deposition of Vanadium Dioxide and a Temperature-dependent Optical Model.

    PubMed

    Currie, Marc; Mastro, Michael A; Wheeler, Virginia D

    2018-05-23

    Vanadium dioxide is a material that has a reversible metal-insulator phase change near 68 °C. To grow VO2 on a wide variety of substrates, with wafer-scale uniformity and angstrom level control of thickness, the method of atomic-layer deposition was chosen. This ALD process enables high-quality, low-temperature (≤150 °C) growth of ultrathin films (100-1000 Å) of VO2. For this demonstration, the VO2 films were grown on sapphire substrates. This low temperature growth technique produces mostly amorphous VO2 films. A subsequent anneal in an ultra-high vacuum chamber with a pressure of 7x10 -4 Pa of ultra-high purity (99.999%) oxygen produced oriented, polycrystalline VO2 films. The crystallinity, phase, and strain of the VO2 were determined by Raman spectroscopy and X-ray diffraction, while the stoichiometry and impurity levels were determined by X-ray photoelectron spectroscopy, and finally the morphology was determined by atomic force microscopy. These data demonstrate the high-quality of the films grown by this technique. A model was created to fit to the data for VO2 in its metallic and insulating phases in the near infrared spectral region. The permittivity and refractive index of the ALD VO2 agreed well with the other fabrication methods in its insulating phase, but showed a difference in its metallic state. Finally, the analysis of the films' optical properties enabled the creation of a wavelength- and temperature-dependent model of the complex optical refractive index for developing VO2 as a tunable refractive index material.

  18. Effect of annealing on optical properties and structure of the vanadium dioxide thin films

    NASA Astrophysics Data System (ADS)

    Zhu, Huiqun; Li, Yi; Li, Yuming; Huang, Yize; Tong, Guoxiang; Fang, Baoying; Zheng, Qiuxin; Li, Liu; Shen, Yujian

    2012-10-01

    VO2 thin films were prepared on soda-lime glass substrates by DC magnetron sputtering at room temperature using vanadium target and post annealing in air. X-ray diffraction and FTIR spectroscopy analyses showed that the films obtained at the optimized parameters have high VO2 (011) orientation. Both low temperature deposition and post annealing method were beneficial to grow the nano-films with pure VO2 phase-structure and composition. Metalinsulator transition properties of the VO2 films in terms of infrared transmittance, transmittance variation and film thickness were investigated under varying annealing temperature. Results showed that infrared transmittance variation and transition temperature of the nano-films were significantly improved and reduced respectively. Therefore, this study was able to develop practical low-cost preparation methods for high-performance intelligent energy-saving thin films.

  19. Tuning of thermally induced first-order semiconductor-to-metal transition in pulsed laser deposited VO2 epitaxial thin films

    NASA Astrophysics Data System (ADS)

    Behera, Makhes K.; Pradhan, Dhiren K.; Pradhan, Sangram K.; Pradhan, Aswini K.

    2017-12-01

    Vanadium oxide (VO2) thin films have drawn significant research and development interest in recent years because of their intriguing physical origin and wide range of functionalities useful for many potential applications, including infrared imaging, smart windows, and energy and information technologies. However, the growth of highly epitaxial films of VO2, with a sharp and distinct controllable transition, has remained a challenge. Here, we report the structural and electronic properties of high quality and reproducible epitaxial thin films of VO2, grown on c-axis oriented sapphire substrates using pulsed laser deposition at different deposition pressures and temperatures, followed by various annealing schedules. Our results demonstrate that the annealing of epitaxial VO2 films significantly enhances the Semiconductor to Metal Transition (SMT) to that of bulk VO2 transition. The effect of oxygen partial pressure during the growth of VO2 films creates a significant modulation of the SMT from around room temperature to as high as the theoretical value of 68 °C. We obtained a bulk order transition ≥104 while reducing the transition temperature close to 60 °C, which is comparatively less than the theoretical value of 68 °C, demonstrating a clear and drastic improvement in the SMT switching characteristics. The results reported here will open the door to fundamental studies of VO2, along with tuning of the transition temperatures for potential applications for multifunctional devices.

  20. Thermal Instability Induced Oriented 2D Pores for Enhanced Sodium Storage.

    PubMed

    Kong, Lingjun; Xie, Chen-Chao; Gu, Haichen; Wang, Chao-Peng; Zhou, Xianlong; Liu, Jian; Zhou, Zhen; Li, Zhao-Yang; Zhu, Jian; Bu, Xian-He

    2018-04-19

    Hierarchical porous structures are highly desired for various applications. However, it is still challenging to obtain such materials with tunable architectures. Here, this paper reports hierarchical nanomaterials with oriented 2D pores by taking advantages of thermally instable bonds in vanadium-based metal-organic frameworks (MOFs). High-temperature calcination of these MOFs accompanied by the loss of coordinated water molecules and other components enables the formation of orderly slit-like 2D pores in vanadium oxide/porous carbon nanorods (VO x /PCs). This unique combination leads to an increase of the reactive surface area. In addition, optimized VO x /PCs demonstrate high-rate capability and ultralong cycling life for sodium storage. The assembled full cells also show high capacity and cycling stability. This report provides an effective strategy for producing MOFs-derived composites with hierarchical porous architectures for energy storage. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Transport properties of ultra-thin VO2 films on (001) TiO2 grown by reactive molecular-beam epitaxy

    NASA Astrophysics Data System (ADS)

    Paik, Hanjong; Moyer, Jarrett A.; Spila, Timothy; Tashman, Joshua W.; Mundy, Julia A.; Freeman, Eugene; Shukla, Nikhil; Lapano, Jason M.; Engel-Herbert, Roman; Zander, Willi; Schubert, Jürgen; Muller, David A.; Datta, Suman; Schiffer, Peter; Schlom, Darrell G.

    2015-10-01

    We report the growth of (001)-oriented VO2 films as thin as 1.5 nm with abrupt and reproducible metal-insulator transitions (MIT) without a capping layer. Limitations to the growth of thinner films with sharp MITs are discussed, including the Volmer-Weber type growth mode due to the high energy of the (001) VO2 surface. Another key limitation is interdiffusion with the (001) TiO2 substrate, which we quantify using low angle annular dark field scanning transmission electron microscopy in conjunction with electron energy loss spectroscopy. We find that controlling island coalescence on the (001) surface and minimization of cation interdiffusion by using a low growth temperature followed by a brief anneal at higher temperature are crucial for realizing ultrathin VO2 films with abrupt MIT behavior.

  2. Transport properties of ultra-thin VO{sub 2} films on (001) TiO{sub 2} grown by reactive molecular-beam epitaxy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paik, Hanjong; Tashman, Joshua W.; Moyer, Jarrett A.

    2015-10-19

    We report the growth of (001)-oriented VO{sub 2} films as thin as 1.5 nm with abrupt and reproducible metal-insulator transitions (MIT) without a capping layer. Limitations to the growth of thinner films with sharp MITs are discussed, including the Volmer-Weber type growth mode due to the high energy of the (001) VO{sub 2} surface. Another key limitation is interdiffusion with the (001) TiO{sub 2} substrate, which we quantify using low angle annular dark field scanning transmission electron microscopy in conjunction with electron energy loss spectroscopy. We find that controlling island coalescence on the (001) surface and minimization of cation interdiffusion bymore » using a low growth temperature followed by a brief anneal at higher temperature are crucial for realizing ultrathin VO{sub 2} films with abrupt MIT behavior.« less

  3. VO{sub 2} (A): Reinvestigation of crystal structure, phase transition and crystal growth mechanisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao Popuri, Srinivasa; University of Bordeaux, ICMCB, UPR 9048, F-33608 Pessac; National Institute for Research and Development in Electrochemistry and Condensed Matter, Timisoara, Plautius Andronescu Str. No. 1, 300224 Timisoara

    2014-05-01

    Well crystallized VO{sub 2} (A) microrods were grown via a single step hydrothermal reaction in the presence of V{sub 2}O{sub 5} and oxalic acid. With the advantage of high crystalline samples, we propose P4/ncc as an appropriate space group at room temperature. From morphological studies, we found that the oriented attachment and layer by layer growth mechanisms are responsible for the formation of VO{sub 2} (A) micro rods. The structural and electronic transitions in VO{sub 2} (A) are strongly first order in nature, and a marked difference between the structural transition temperatures and electronic transitions temperature was evidenced. The reversiblemore » intra- (LTP-A to HTP-A) and irreversible inter- (HTP-A to VO{sub 2} (M1)) structural phase transformations were studied by in-situ powder X-ray diffraction. Attempts to increase the size of the VO{sub 2} (A) microrods are presented and the possible formation steps for the flower-like morphologies of VO{sub 2} (M1) are described. - Graphical abstract: Using a single step and template free hydrothermal synthesis, well crystallized VO{sub 2} (A) microrods were prepared and the P4/ncc space group was assigned to the room temperature crystal structure. Reversible and irreversible phase transitions among different VO{sub 2} polymorphs were identified and their progressive nature was highlighted. Attempts to increase the microrods size, involving layer by layer formation mechanisms, are presented. - Highlights: • Highly crystallized VO{sub 2} (A) microrods were grown via a single step hydrothermal process. • The P4/ncc space group was determined for VO{sub 2} (A) at room temperature. • The electronic structure and progressive nature of the structural phase transition were investigated. • A weak coupling between structural and electronic phase transitions was identified. • Different crystallite morphologies were discussed in relation with growth mechanisms.« less

  4. Voltage-induced switching dynamics based on an AZO/VO2/AZO sandwiched structure

    NASA Astrophysics Data System (ADS)

    Xiao, Han; Li, Yi; Fang, Baoying; Wang, Xiaohua; Liu, Zhimin; Zhang, Jiao; Li, Zhengpeng; Huang, Yaqin; Pei, Jiangheng

    2017-11-01

    A vanadium dioxide (VO2) thin film was prepared on an Al-doped ZnO (AZO) conductive glass substrate by DC magnetron sputtering and a post-annealing process. The AZO/VO2/AZO sandwiched structure was fabricated on the VO2/AZO composite film using photolithography and a chemical etching process. The composition, microstructure and optical properties of the VO2/AZO composite film were tested. The results showed that the VO2/AZO composite film was poly-crystalline and the AZO layer did not change the preferred growth orientation of VO2. When the voltage was applied on both of the transparent conductive layers of the AZO/VO2/AZO sandwiched structure, an abrupt change in the current was observed at different temperatures. The temperature dependence of I-V characteristic curves for the AZO/VO2/AZO sandwiched structure was analyzed. The phase transition voltage value is 7.5 V at 20 °C and decreases with increasing temperature.

  5. C-oriented and {010} facets exposed BiVO4 nanowall films: template-free fabrication and their enhanced photoelectrochemical properties.

    PubMed

    Zhou, Min; Zhang, Shudong; Sun, Yongfu; Wu, Changzheng; Wang, Mingtai; Xie, Yi

    2010-12-03

    Vertically aligned BiVO(4) nanowall films on indium tin oxide (ITO) glass have been fabricated through a template-free hydrothermal method for the first time. Based on the structural understanding of both BiVO(4) and ITO, the lattice matches ({020}(BiVO4) and {040}(ITO), {200}(BiVO4) and {004}(ITO), respectively) and the similarity of metal atomic arrangement parallel to {001} planes turn out to be crucial for the fabrication of the nanowalls. Consequently, the growth of a BiVO(4) film begins from heteroepitaxy and undergoes an Ostwald ripening process to form an extended network, resulting in a c-orientation and exposing {010} facets. Through this process, it is much easier to obtain a range of nanowall films with different packing densities, as the surface state of ITO glass is alterable by adjusting the concentration of acid. The films can be directly used as an electrode, which exhibits an excellent response to visible light, especially light with low intensity, allowing for the electrical interconnection, highly active surface, appropriate orientation, and a good contact with the substrate. There are great benefits in improving the technique for detecting the weak light source signals.

  6. Fabrication of vanadium dioxide polycrystalline films with higher temperature coefficient of resistance

    NASA Astrophysics Data System (ADS)

    Li, Jinhua; Yuan, Ningyi; Jiang, Meiping; Kun, Li

    2011-08-01

    Vanadium Dioxide Polycrystalline Films with High Temperature Coefficient of Resistance(TCR) were fabricated by modified Ion Beam Enhanced Deposition(IBED) method. The TCR of the Un-doping VO2 was about -4%/K at room temperature after appropriate thermal annealing. The XRD results clearly showed that IBED polycrystalline VO2 films had a single [002] orientation of VO2(M). The TCR of 5at.%W and 7at.% Ta doped Vanadium Dioxide Polycrystalline Films were high up to -18%/K and -12%/K at room temperature, respectively. Using 7at.% Ta and 2at.% Ti co-doping, the TCR of the co-doped vanadium oxide film was -7%/K and without hysteresis during temperature increasing and decresing from 0-80°C. It should indicate that the W-doped vanadium dioxide films colud be used for high sensing IR detect and the Ta/Ti co-doped film without hysteresis is suitable for infrarid imaging application.

  7. Electron Microscopy Characterization of Vanadium Dioxide Thin Films and Nanoparticles

    NASA Astrophysics Data System (ADS)

    Rivera, Felipe

    Vanadium dioxide (VO_2) is a material of particular interest due to its exhibited metal to insulator phase transition at 68°C that is accompanied by an abrupt and significant change in its electronic and optical properties. Since this material can exhibit a reversible drop in resistivity of up to five orders of magnitude and a reversible drop in infrared optical transmission of up to 80%, this material holds promise in several technological applications. Solid phase crystallization of VO_2 thin films was obtained by a post-deposition annealing process of a VO_{x,x approx 2} amorphous film sputtered on an amorphous silicon dioxide (SiO_2) layer. Scanning electron microscopy (SEM) and electron-backscattered diffraction (EBSD) were utilized to study the morphology of the solid phase crystallization that resulted from this post-deposition annealing process. The annealing parameters ranged in temperature from 300°C up to 1000°C and in time from 5 minutes up to 12 hours. Depending on the annealing parameters, EBSD showed that this process yielded polycrystalline vanadium dioxide thin films, semi-continuous thin films, and films of isolated single-crystal particles. In addition to these films on SiO_2, other VO_2 thin films were deposited onto a-, c-, and r-cuts of sapphire and on TiO_2(001) heated single-crystal substrates by pulsed-laser deposition (PLD). The temperature of the substrates was kept at ˜500°C during deposition. EBSD maps and orientation imaging microscopy were used to study the epitaxy and orientation of the VO_2 grains deposited on the single crystal substrates, as well as on the amorphous SiO_2 layer. The EBSD/OIM results showed that: 1) For all the sapphire substrates analyzed, there is a predominant family of crystallographic relationships wherein the rutile VO_2{001} planes tend to lie parallel to the sapphire's {10-10} and the rutile VO_2{100} planes lie parallel to the sapphire's {1-210} and {0001}. Furthermore, while this family of relationships accounts for the majority of the VO_2 grains observed, due to the sapphire substrate's geometry there were variations within these rules that changed the orientation of VO_2 grains with respect to the substrate's normal direction. 2) For the TiO_2, a substrate with a lower lattice mismatch, we observe the expected relationship where the rutile VO_2 [100], [110], and [001] crystal directions lie parallel to the TiO_2 substrate's [100], [110], and [001] crystal directions respectively. 3) For the amorphous SiO_2 layer, all VO_2 crystals that were measurable (those that grew to the thickness of the deposited film) had a preferred orientation with the the rutile VO_2[001] crystal direction tending to lie parallel to the plane of the specimen. The use of transmission electron microscopy (TEM) is presented as a tool for further characterization studies of this material and its applications. In this work TEM diffraction patterns taken from cross-sections of particles of the a- and r-cut sapphire substrates not only solidified the predominant family mentioned, but also helped lift the ambiguity present in the rutile VO_2{100} axes. Finally, a focused-ion beam technique for preparation of cross-sectional TEM samples of metallic thin films deposited on polymer substrates is demonstrated.

  8. Coherently coupled ZnO and VO2 interface studied by photoluminescence and electrical transport across a phase transition

    NASA Astrophysics Data System (ADS)

    Srivastava, Amar; Herng, T. S.; Saha, Surajit; Nina, Bao; Annadi, A.; Naomi, N.; Liu, Z. Q.; Dhar, S.; Ariando; Ding, J.; Venkatesan, T.

    2012-06-01

    We have investigated the photoluminescence and electrical properties of a coherently coupled interface consisting of a ZnO layer grown on top of an oriented VO2 layer on sapphire across the phase transition of VO2. The band edge and defect luminescence of the ZnO overlayer exhibit hysteresis in opposite directions induced by the phase transition of VO2. Concomitantly the phase transition of VO2 was seen to induce defects in the ZnO layer. Such coherently coupled interfaces could be of use in characterizing the stability of a variety of interfaces in situ and also for novel device application.

  9. Microstructures and thermochromic characteristics of VO2/AZO composite films

    NASA Astrophysics Data System (ADS)

    Xiao, Han; Li, Yi; Yuan, Wenrui; Fang, Baoying; Wang, Xiaohua; Hao, Rulong; Wu, Zhengyi; Xu, Tingting; Jiang, Wei; Chen, Peizu

    2016-05-01

    A vanadium dioxide (VO2) thin film was fabricated on a ZnO doped with Al (AZO) conductive glass by magnetron sputtering at room temperature followed by annealing under air atmosphere. The microstructures and optical properties of the thin film were studied. The results showed that the VO2/AZO composite film was poly-crystalline and the AZO layer did not change the preferred growth orientation of VO2. Compared to the VO2 film fabricated on soda-lime glass substrate through the same process and condition, the phase transition temperature of the VO2/AZO composite film was decreased by about 25 °C, thermal hysteresis width narrowed to 6 °C, the visible light transmittance was over 50%, the infrared transmittances before and after phase transition were 21% and 55%, respectively at 1500 nm.

  10. Role of indium tin oxide electrode on the microstructure of self-assembled WO3-BiVO4 hetero nanostructures

    NASA Astrophysics Data System (ADS)

    Song, Haili; Li, Chao; Van, Chien Nguyen; Dong, Wenxia; Qi, Ruijuan; Zhang, Yuanyuan; Huang, Rong; Chu, Ying-Hao; Duan, Chun-Gang

    2017-11-01

    Self-assembled WO3-BiVO4 nanostructured thin films were grown on a (001) yttrium stabilized zirconia (YSZ) substrate by the pulsed laser deposition method with and without the indium tin oxide (ITO) bottom electrode. Their microstructures including surface morphologies, crystalline phases, epitaxial relationships, interface structures, and composition distributions were investigated by scanning electron microscopy, high-resolution transmission electron microscopy, and X-ray energy dispersive spectroscopy. In both samples, WO3 formed nanopillars embedded into the monoclinic BiVO4 matrix with specific orientation relationships. In the sample with the ITO bottom electrode, an atomically sharp BiVO4/ITO interface was formed and the orthorhombic WO3 nanopillars were grown on a relaxed BiVO4 buffer layer with a mixed orthorhombic and hexagonal WO3 transition layer. In contrast, a thin amorphous layer appears at the interfaces between the thin film and the YSZ substrate in the sample without the ITO electrode. In addition, orthorhombic Bi2WO6 lamellar nanopillars were formed between WO3 and BiVO4 due to interdiffusion. Such a WO3-Bi2WO6-BiVO4 double heterojunction photoanode may promote the photo-generated charge separation and further improve the photoelectrochemical water splitting properties.

  11. Changes in blood lactate and respiratory gas exchange measures in sports with discontinuous load profiles.

    PubMed

    Smekal, Gerhard; von Duvillard, Serge P; Pokan, Rochus; Tschan, Harald; Baron, Ramon; Hofmann, Peter; Wonisch, Manfred; Bachl, Norbert

    2003-06-01

    This study compares two different sport events (orienteering = OTC; tennis = TEC) with discontinuous load profiles and different activity/recovery patterns by means of blood lactate (LA), heart rate (HR), and respiratory gas exchange measures (RGME) determined via a portable respiratory system. During the TEC, 20 tennis-ranked male subjects [age: 26.0 (3.7) years; height: 181.0 (5.7) cm; weight: 73.2 (6.8) kg; maximal oxygen consumption (VO(2)max): 57.3 (5.1) ml.kg(-1).min(-1)] played ten matches of 50 min. During the OTC, 11 male members of the Austrian National Team [age: 23.5 (3.9) years; height: 183.6 (6.8) cm; weight: 72.4 (3.9) kg; VO(2)max: 67.9 (3.8) ml.kg(-1).min(-1)] performed a simulated OTC (six sections; average length: 10.090 m). In both studies data from the maximal treadmill tests (TT) were used as reference values for the comparison of energy expenditure of OTC and TEC. During TEC, the average VO(2) was considerably lower [29.1 (5.6) ml(.)kg(-1.)min(-1)] or 51.1 (10.9)% of VO(2)max and 64.8.0 (13.3)% of VO(2) determined at the individual anaerobic threshold (IAT) on the TT. The short high-intensity periods (activity/recovery = 1/6) did not result in higher LA levels [average LA of games: 2.07 (0.9) mmol.l(-1)]. The highest average VO(2 )value for a whole game was 47.8 ml.kg(-1.)min(-1) and may provide a reference for energy demands required to sustain high-intensity periods of tennis predominantly via aerobic mechanism of energy delivery. During OTC, we found an average VO(2) of 56.4 (4.5) ml.kg(-1).min(-1) or 83.0 (3.8)% of VO(2)max and 94.6 (5.2)% of VO(2) at IAT. In contrast to TEC, LA were relatively high [5.16 (1.5) mmol.l(-1)) although the average VO(2) was significantly lower than VO(2) at IAT. Our data suggest that portable RGEM provides valuable information concerning the energy expenditure in sports that cannot be interpreted from LA or HR measures alone. Portable RGEM systems provide valuable assessment of under- or over-estimation of requirements of sports and assist in the optimization and interpretation of training in athletes.

  12. Oxidizing annealing effects on VO2 films with different microstructures

    NASA Astrophysics Data System (ADS)

    Dou, Yan-Kun; Li, Jing-Bo; Cao, Mao-Sheng; Su, De-Zhi; Rehman, Fida; Zhang, Jia-Song; Jin, Hai-Bo

    2015-08-01

    Vanadium dioxide (VO2) films have been prepared by direct-current magnetron sputter deposition on m-, a-, and r-plane sapphire substrates. The obtained VO2 films display different microstructures depending on the orientation of sapphire substrates, i.e. mixed microstructure of striped grains and equiaxed grains on m-sapphire, big equiaxed grains on a-sapphire and fine-grained microstructure on r-sapphire. The VO2 films were treated by the processes of oxidation in air. The electric resistance and infrared transmittance of the oxidized films were characterized to examine performance characteristics of VO2 films with different microstructures in oxidation environment. The oxidized VO2 films on m-sapphire exhibit better electrical performance than the other two films. After air oxidization for 600 s at 450 °C, the VO2 films on m-sapphire show a resistance change of 4 orders of magnitude over the semiconductor-to-metal transition. The oxidized VO2 films on a-sapphire have the highest optical modulation efficiency in infrared region compared to other samples. The different performance characteristics of VO2 films are understood in terms of microstructures, i.e. grain size, grain shape, and oxygen vacancies. The findings reveal the correlation of microstructures and performances of VO2 films, and provide useful knowledge for the design of VO2 materials to different applications.

  13. Metal-insulator transition properties of sputtered silicon-doped and un-doped vanadium dioxide films at terahertz range

    NASA Astrophysics Data System (ADS)

    Zhang, Huafu; Wu, Zhiming; Niu, Ruihua; Wu, Xuefei; he, Qiong; Jiang, Yadong

    2015-03-01

    Silicon-doped and un-doped vanadium dioxide (VO2) films were synthesized on high-purity single-crystal silicon substrates by means of reactive direct current magnetron sputtering followed by thermal annealing. The structure, morphology and metal-insulator transition properties of silicon-doped VO2 films at terahertz range were measured and compared to those of un-doped VO2 films. X-ray diffraction and scanning electron microscopy indicated that doping the films with silicon significantly affects the preferred crystallographic orientation and surface morphologies (grain size, pores and characteristics of grain boundaries). The temperature dependence of terahertz transmission shows that the transition temperature, hysteresis width and transition sharpness greatly depend on the silicon contents while the transition amplitude was relatively insensitive to the silicon contents. Interestingly, the VO2 film doped with a silicon content of 4.6 at.% shows excellent terahertz switching characteristics, namely a small hysteresis width of 4.5 °C, a giant transmission modulation ratio of about 82% and a relatively low transition temperature of 56.1 °C upon heating. This work experimentally indicates that silicon doping can effectively control not only the surface morphology but also the metal-insulator transition characteristics of VO2 films at terahertz range.

  14. Orientation of Vanadium Dioxide Grains on Various Substrates

    NASA Astrophysics Data System (ADS)

    Rivera, Felipe; Davis, Robert; Vanfleet, Richard

    2010-10-01

    Crystalline vanadium dioxide VO2 experiences a fast and reversible semiconductor-to-metal structural phase transition near 68^oC. The changes exhibited during this phase transition comprise a well known change in resistivity of several orders of magnitude, as well as a significant drop in optical transmittance in the infrared. Due to the changes in these optical and electronic properties, vanadium dioxide shows promise as a material to be used in many applications ranging from thermochromic window coatings to optoelectronic devices. However, since there is a structural component to the phase transition of VO2, it is of interest to study the orientation of the crystalline grains deposited. Substrates such as glass, SiO2, Sapphire, and TiO2 have been used for the deposition of this material. We used orientation imaging microscopy to study and characterize the orientation of the grains deposited on several of these substrates. Here we present results on this study.

  15. Influence of oxygen flow rate on metal-insulator transition of vanadium oxide thin films grown by RF magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Ma, Xu; Liu, Xinkun; Li, Haizhu; Zhang, Angran; Huang, Mingju

    2017-03-01

    High-quality vanadium oxide ( VO2) films have been fabricated on Si (111) substrates by radio frequency (RF) magnetron sputtering deposition method. The sheet resistance of VO2 has a significant change (close to 5 orders of magnitude) in the process of the metal-insulator phase transition (MIT). The field emission-scanning electron microscope (FE-SEM) results show the grain size of VO2 thin films is larger with the increase of oxygen flow. The X-ray diffraction (XRD) results indicate the thin films fabricated at different oxygen flow rates grow along the (011) crystalline orientation. As the oxygen flow rate increases from 3 sccm to 6 sccm, the phase transition temperature of the films reduces from 341 to 320 K, the width of the thermal hysteresis loop decreases from 32 to 9 K. The thin films fabricated in the condition of 5 sccm have a high temperature coefficient of resistance (TCR) -3.455%/K with a small resistivity of 2.795 ρ/Ω cm.

  16. Study of the resonant frequencies of silicon microcantilevers coated with vanadium dioxide films during the insulator-to-metal transition

    NASA Astrophysics Data System (ADS)

    Rúa, Armando; Fernández, Félix E.; Hines, Melissa A.; Sepúlveda, Nelson

    2010-03-01

    Vanadium dioxide (VO2) thin films were grown on silicon microcantilevers and companion test substrates by pulsed laser deposition followed by in situ annealing in an oxidizing atmosphere, with annealing times used to control crystallite sizes. Annealing times of 18 min produced VO2 films with average crystallite sizes of ˜10 nm or less, while those annealed for 35 min had crystallites of average size ˜90 nm, comparable to sample thickness. X-ray diffraction and x-ray photoelectron spectroscopy studies of the samples showed that films with crystallite sizes ˜40 nm or greater consisted of substoichiometric VO2 in its monoclinic phase, with preferential orientation with (011) planes parallel to the sample surface, while finer structured samples had a substantially similar composition, but showed no clear evidence of preferential orientation and were probably partially amorphous. Forced vibration experiments were performed with the cantilevers as they were thermally cycled through the VO2 insulator-to-metal transition (IMT). Very large reversible changes in the resonant frequencies of up to 5% (3.6 kHz) as well as hysteretic behavior were observed, which depend strongly on film crystallite size. The average value of Young's modulus for VO2 films with crystallite sizes of ˜90 nm was estimated from the mechanical resonance data at room temperature to be ˜120 GPa, but the large tensile stresses which develop between film and substrate through the IMT impede a similar determination for the VO2 tetragonal phase, since the commonly used relationships for cantilever frequencies derived from elasticity theory are not applicable for strongly curved composite beams. The results presented show that VO2 thin films can be useful in novel microscale and nanoscale electromechanical resonators in which effective stiffness can be tuned thermally or optically. This response can provide additional functionality to VO2—based devices which take advantage of other property changes through the IMT.

  17. Sharpness and intensity modulation of the metal-insulator transition in ultrathin VO2 films by interfacial structure manipulation

    NASA Astrophysics Data System (ADS)

    McGee, Ryan; Goswami, Ankur; Pal, Soupitak; Schofield, Kalvin; Bukhari, Syed Asad Manzoor; Thundat, Thomas

    2018-03-01

    Vanadium dioxide (VO2) undergoes a structural transformation from monoclinic (insulator) to tetragonal (metallic) upon heating above 340 K, accompanied by abrupt changes to its electronic, optical, and mechanical properties. Not only is this transition scientifically intriguing, but there are also numerous applications in sensing, memory, and optoelectronics. Here we investigate the effect different substrates and the processing conditions have on the characteristics metal-insulator transition (MIT), and how the properties can be tuned for specific applications. VO2 thin films were grown on c -plane sapphire (0001) and p-type silicon <100 > by pulsed laser deposition. High-resolution x-ray diffraction along with transmission electron microscopy reveals textured epitaxial growth on sapphire by domain-matching epitaxy, while the presence of a native oxide layer on silicon prevented any preferential growth resulting in a polycrystalline film. An orientation relationship of <001 > (010)VO2||<11 ¯00 > (0001)Al 2O3 was established for VO2 grown on sapphire, while no such relationship was found for VO2 grown on silicon. Surface-energy minimization is the driving force behind grain growth, as the lowest energy VO2 plane grew on silicon, while on sapphire the desire for epitaxial growth was dominant. Polycrystallinity of films grown on silicon caused a weaker and less prominent MIT than observed on sapphire, whose MIT was higher in magnitude and steeper in slope. The position of the MIT was shown to depend on the competing effects of misfit strain and grain growth. Higher deposition temperatures caused an increase in the MIT, while compressive strain resulted in a decreased MIT.

  18. Thermochromic VO2 on Zinnwaldite Mica by pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Mathevula, L.; Ngom, B. D.; Kotsedi, L.; Sechogela, P.; Doyle, T. B.; Ghouti, M.; Maaza, M.

    2014-09-01

    VO2 thin films have been deposited by pulsed laser deposition on Zinnwaldite Mica substrates. The crystal structure, chemical composition, morphology were determined and the semiconductor/metal transition (SMT) properties of the deposited films were investigated. Without any post annealing, the films exhibit a textured nature with a VO2 (0 1 1) preferred crystallographic orientation and an elevated thermal variation of the electric resistance ratio RS/RM through the SMT at T ≈ 68 °C of the order of 104 and a narrow ∼7 °C hysteresis. In addition, the growth of the VO2 crystallites seem to be governed likely by a Volmer-Weber or Stranski-Krastanov mechanisms and certainly not a Frank-van Der Merwe process.

  19. Structural and electrical properties of large area epitaxial VO2 films grown by electron beam evaporation

    NASA Astrophysics Data System (ADS)

    Théry, V.; Boulle, A.; Crunteanu, A.; Orlianges, J. C.; Beaumont, A.; Mayet, R.; Mennai, A.; Cosset, F.; Bessaudou, A.; Fabert, M.

    2017-02-01

    Large area (up to 4 squared inches) epitaxial VO2 films, with a uniform thickness and exhibiting an abrupt metal-insulator transition with a resistivity ratio as high as 2.85 × 10 4 , have been grown on (001)-oriented sapphire substrates by electron beam evaporation. The lattice distortions (mosaicity) and the level of strain in the films have been assessed by X-ray diffraction. It is demonstrated that the films grow in a domain-matching mode where the distortions are confined close to the interface which allows growth of high-quality materials despite the high film-substrate lattice mismatch. It is further shown that a post-deposition high-temperature oxygen annealing step is crucial to ensure the correct film stoichiometry and provide the best structural and electrical properties. Alternatively, it is possible to obtain high quality films with a RF discharge during deposition, which hence do not require the additional annealing step. Such films exhibit similar electrical properties and only slightly degraded structural properties.

  20. Control of electromagnetically induced transparency via a hybrid semiconductor quantum dot-vanadium dioxide nanoparticle system

    NASA Astrophysics Data System (ADS)

    Zamani, Naser; Hatef, Ali; Nadgaran, Hamid; Keshavarz, Alireza

    2017-07-01

    We numerically investigate the electromagnetically induced transparency (EIT) of a hybrid system consisting of a three-level quantum dot (QD) in the vicinity of vanadium dioxide nanoparticle (VO2NP). VO2NP has semiconductor and metallic phases where the transition between the two phases occurs around a critical temperature. When the QD-VO2NP hybrid system interacts with continuous wave laser fields in an infrared regime, it supports a coherent coupling of exciton-polariton and exciton-plasmon polariton in semiconductor and metal phases of VO2NP, respectively. In our calculations a filling fraction factor controls the VO2NP phase transition. A probe and control laser field configuration is studied for the hybrid system to measure the absorption of QD through the filling fraction factor manipulations. We show that for the VO2NP semiconductor phase and proper geometrical configuration, the absorption spectrum profile of the QD represents an EIT with two peaks and a clear minimum. These two peaks merge to one through the VO2NP phase transition to metal. We also show that the absorption spectrum profile is modified by different orientations of the laser fields with the axis of the QD-VO2NP hybrid system. The innovation in comparison to other research in the field is that robust variation in the absorption profile through EIT is due to the phase transition in VO2NP without any structural change in the QD-VO2NP hybrid system. Our results can be employed to design nanothermal sensors, optical nanoswitches, and energy transfer devices.

  1. Role of interfacial transition layers in VO2/Al2O3 heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Honghui; Chisholm, Matthew F; Yang, Tsung-Han

    2011-01-01

    Epitaxial VO2 films grown by pulsed laser deposition (PLD) on c-cut sapphire substrates ((0001) Al2O3) were studied by aberration-corrected scanning transmission electron microscopy (STEM). A number of film/substrate orientation relationships were found and are discussed in the context of the semiconductor-metal transition (SMT) characteristics. A structurally and electronically modified buffer layer was revealed on the interface and was attributed to the interface free-energy minimization process of accommodating the symmetry mismatch between the substrate and the film. This interfacial transition layer is expected to affect the SMT behavior when the interfacial region is a significant fraction of the VO2 film thickness.

  2. Vanadium dioxide thin films prepared on silicon by low temperature MBE growth and ex-situ annealing

    NASA Astrophysics Data System (ADS)

    Homm, Pia; van Bilzen, Bart; Menghini, Mariela; Locquet, Jean-Pierre; Ivanova, Todora; Sanchez, Luis; Sanchis, Pablo

    Vanadium dioxide (VO2) is a material that shows an insulator to metal transition (IMT) near room temperature. This property can be exploited for applications in field effect devices, electro-optical switches and nonlinear circuit components. We have prepared VO2 thin films on silicon wafers by combining a low temperature MBE growth with an ex-situ annealing at high temperature. We investigated the structural, electrical and optical characteristics of films with thicknesses ranging from 10 to 100 nm. We have also studied the influence of the substrate cleaning. The films grown with our method are polycrystalline with a preferred orientation in the (011) direction of the monoclinic phase. For the films produced on silicon with a native oxide, an IMT at around 75 °C is observed. The magnitude of the resistance change across the IMT decreases with thickness while the refractive index at room temperature corresponds with values reported in the literature for thin films. The successful growth of VO2 films on silicon with good electrical and optical properties is an important step towards the integration of VO2 in novel devices. The authors acknowledge financial support from the FWO project G052010N10 and EU-FP7 SITOGA project. PH acknowledges support from Becas Chile - CONICYT.

  3. Coherently Coupled ZnO and VO2 Interface studied by Photoluminescence and electrical transport across a phase transition

    NASA Astrophysics Data System (ADS)

    Srivastava, Amar; Saha, S.; Annadi, A.; Zhao, Y. L.; Gopinadhan, K.; Wang, X.; Naomi, N.; Liu, Z. Q.; Dhar, S.; Herng, T. S.; Nina, Bao; Ariando, -; Ding, Jun; Venkatesan, T.

    2012-02-01

    In this work we report a study of a coherently coupled interface consisting of a ZnO layer grown on top of an oriented VO2 layer on sapphire by photoluminescence and electrical transport measurements across the VO2 metal insulator phase transition (MIT). The photoluminescence of the ZnO layer showed a broad hysteresis induced by the phase transition of VO2 while the width of the electrical hysteresis was narrow and unaffected by the over layer. The enhanced width of the PL hysteresis was due to the formation of defects during the MIT as evidenced by a broad hysteresis in the opposite direction to that of the band edge PL in the defect luminescense. Unlike VO2 the defects in ZnO did not fully recover across the phase transition. From the defect luminescence data, oxygen interstitials were found to be the predominant defects in ZnO mediated by the strain from the VO2 phase transition. Such coherently coupled interfaces could be of use in characterizing the stability of a variety of interfaces and also for novel device application.

  4. Effects of Zirconium Ions Doping on the Structural and Thermochromic Properties of VO2 Thin Films

    NASA Astrophysics Data System (ADS)

    Li, Yuanbao; Liu, Juncheng; Wang, Danping; Dang, Yuanyuan

    2017-11-01

    As an inorganic functional material, VO2 thin films are expected to be used for smart windows. However, these films are not conducive to practical applications when the phase transition temperature ( Tc) of the VO2 is approximately 68°C, which is greater than room temperature. To decrease Tc, the effect of Zr4+ doping on the structure and properties of VO2 films were investigated. The films were prepared using a sol-gel process, spin-coating on quartz glasses, and annealing at 525°C in a tube furnace within a nitrogen atmosphere. The results demonstrate that these films have a highly preferential crystalline orientation on the substrate; however, the primary two x-ray diffraction pattern peaks shift slightly toward the small angle, and when 7 at.% Zr4+ was doped in the VO2 film, the deviation angle was 0.16°, and the crystallite size was approximately 98 nm. A large number of grains were found on the surface of the pure VO2 films, but all the Zr4+ doped films had a layered structure, and the thickness of the films was approximately 200 nm. The Tc of these films was characterized using differential scanning calorimetry, and the luminous and solar transmittance was characterized using a UV-Vis-NIR spectrophotometer, which demonstrated that the effect of Zr4+ doping decreased Tc by approximately 1°C per 1 at.% on average, and the Tc of the 7 at.% film was slightly greater than that of the 5 at.% film, the phase transition temperature of which was 61.4°C. The transmittance decreased as the doping concentration increased, and 1 at.% Zr4+ doping increased the luminous regulation efficiency (Δ T lum) and solar modulation efficiency (Δ T sol). The Δ T lum of the pure VO2 film and the 1 at.% Zr4+-doped VO2 films was 10.9% and 11.2%, and Δ T sol was 14.4 and 15.2%, respectively.

  5. Structural and magnetic characterization of the one-dimensional S = 5/2 antiferromagnetic chain system SrMn(VO 4)(OH)

    DOE PAGES

    Sanjeewa, Liurukara D.; Garlea, Vasile O.; McGuire, Michael A.; ...

    2016-06-06

    The descloizite-type compound, SrMn(VO 4)(OH), was synthesized as large single crystals (1-2mm) using a high-temperature high-pressure hydrothermal technique. X-ray single crystal structure analysis reveals that the material crystallizes in the acentric orthorhombic space group of P2 12 12 1 (no. 19), Z = 4. The structure exhibits a one-dimensional feature, with [MnO 4] chains propagating along the a-axis which are interconnected by VO 4 tetrahedra. Raman and infrared spectra were obtained to identify the fundamental vanadate and hydroxide vibrational modes. Magnetization data reveal a broad maximum at approximately 80 K, arising from one-dimensional magnetic correlations with intrachain exchange constant ofmore » J/k B = 9.97(3) K between nearest Mn neighbors and a canted antiferromagnetic behavior below T N = 30 K. Single crystal neutron diffraction at 4 K yielded a magnetic structure solution in the lower symmetry of the magnetic space group P2 1 with two unique chains displaying antiferromagnetically ordered Mn moments oriented nearly perpendicular to the chain axis. Lastly, the presence of the Dzyaloshinskii Moriya antisymmetric exchange interaction leads to a slight canting of the spins and gives rise to a weak ferromagnetic component along the chain direction.« less

  6. Coding of Velocity Storage in the Vestibular Nuclei.

    PubMed

    Yakushin, Sergei B; Raphan, Theodore; Cohen, Bernard

    2017-01-01

    Semicircular canal afferents sense angular acceleration and output angular velocity with a short time constant of ≈4.5 s. This output is prolonged by a central integrative network, velocity storage that lengthens the time constants of eye velocity. This mechanism utilizes canal, otolith, and visual (optokinetic) information to align the axis of eye velocity toward the spatial vertical when head orientation is off-vertical axis. Previous studies indicated that vestibular-only (VO) and vestibular-pause-saccade (VPS) neurons located in the medial and superior vestibular nucleus could code all aspects of velocity storage. A recently developed technique enabled prolonged recording while animals were rotated and received optokinetic stimulation about a spatial vertical axis while upright, side-down, prone, and supine. Firing rates of 33 VO and 8 VPS neurons were studied in alert cynomolgus monkeys. Majority VO neurons were closely correlated with the horizontal component of velocity storage in head coordinates, regardless of head orientation in space. Approximately, half of all tested neurons (46%) code horizontal component of velocity in head coordinates, while the other half (54%) changed their firing rates as the head was oriented relative to the spatial vertical, coding the horizontal component of eye velocity in spatial coordinates. Some VO neurons only coded the cross-coupled pitch or roll components that move the axis of eye rotation toward the spatial vertical. Sixty-five percent of these VO and VPS neurons were more sensitive to rotation in one direction (predominantly contralateral), providing directional orientation for the subset of VO neurons on either side of the brainstem. This indicates that the three-dimensional velocity storage integrator is composed of directional subsets of neurons that are likely to be the bases for the spatial characteristics of velocity storage. Most VPS neurons ceased firing during drowsiness, but the firing rates of VO neurons were unaffected by states of alertness and declined with the time constant of velocity storage. Thus, the VO neurons are the prime components of the mechanism of coding for velocity storage, whereas the VPS neurons are likely to provide the path from the vestibular to the oculomotor system for the VO neurons.

  7. Coding of Velocity Storage in the Vestibular Nuclei

    PubMed Central

    Yakushin, Sergei B.; Raphan, Theodore; Cohen, Bernard

    2017-01-01

    Semicircular canal afferents sense angular acceleration and output angular velocity with a short time constant of ≈4.5 s. This output is prolonged by a central integrative network, velocity storage that lengthens the time constants of eye velocity. This mechanism utilizes canal, otolith, and visual (optokinetic) information to align the axis of eye velocity toward the spatial vertical when head orientation is off-vertical axis. Previous studies indicated that vestibular-only (VO) and vestibular-pause-saccade (VPS) neurons located in the medial and superior vestibular nucleus could code all aspects of velocity storage. A recently developed technique enabled prolonged recording while animals were rotated and received optokinetic stimulation about a spatial vertical axis while upright, side-down, prone, and supine. Firing rates of 33 VO and 8 VPS neurons were studied in alert cynomolgus monkeys. Majority VO neurons were closely correlated with the horizontal component of velocity storage in head coordinates, regardless of head orientation in space. Approximately, half of all tested neurons (46%) code horizontal component of velocity in head coordinates, while the other half (54%) changed their firing rates as the head was oriented relative to the spatial vertical, coding the horizontal component of eye velocity in spatial coordinates. Some VO neurons only coded the cross-coupled pitch or roll components that move the axis of eye rotation toward the spatial vertical. Sixty-five percent of these VO and VPS neurons were more sensitive to rotation in one direction (predominantly contralateral), providing directional orientation for the subset of VO neurons on either side of the brainstem. This indicates that the three-dimensional velocity storage integrator is composed of directional subsets of neurons that are likely to be the bases for the spatial characteristics of velocity storage. Most VPS neurons ceased firing during drowsiness, but the firing rates of VO neurons were unaffected by states of alertness and declined with the time constant of velocity storage. Thus, the VO neurons are the prime components of the mechanism of coding for velocity storage, whereas the VPS neurons are likely to provide the path from the vestibular to the oculomotor system for the VO neurons. PMID:28861030

  8. Structure and Properties of VO2 and Titanium Dioxide Based Epitaxial Heterostructures Integrated with Silicon and Sapphire Substrates

    NASA Astrophysics Data System (ADS)

    Bayati, Mohammad Reza

    The main focus of this study was placed on structure-property correlation in TiO2 and VO2 based epitaxial heterostructures where the photochemical and electrical properties were tuned through microstructural engineering. In the framework of domain matching epitaxy, epitaxial growth of TiO2 and VO2 heterostructures on different substrates were explained. The theta-2theta and ϕ scan X-ray diffraction measurements and detailed high resolution electron microscopy studies corroborated our understanding of the epitaxial growth and the crystallographic arrangement across the interfaces. The influence of the laser and substrate variables on structural characteristics of the films was investigated using X-ray photoelectron spectroscopy, room temperature photoluminescence spectroscopy, and UV-Vis spectrophotometry. In addition, morphological studies were performed by atomic force microscopy. Photochemical properties of the heterostructures were assessed through measuring surface wettability characteristics and photocatalytic reaction rate constant of degradation of 4-chlorophenol under ultraviolet and visible irradiations. We also studied electrical properties employing 4-probe measurement technique. The effect of post treatment processes, such as vacuum annealing and laser treatment, on structure and properties was investigated as well. The role of point defects and deviation from the stoichiometry on photochemical and electrical properties was addressed. In this research, TiO2 epilayers with controlled phase structure, defect content, and crystallographic alignments were grown on sapphire and silicon substrates. Integration with silicon was achieved using cubic and tetragonal yttria-stabilized zirconia buffer layers. I was able to tune the phase structure of the TiO2 based heterostructures from pure rutile to pure anatase and establish an epitaxial relationship across the interfaces in each case. These heterostructures were used for two different purposes. First, their application in environmental remediation was taken into account. The photochemical efficiency of the samples was evaluated under ultraviolet and visible illuminations. I was able to establish a correlation between the growth conditions and the photocatalytic activity of single crystalline TiO 2 thin films. Visible-light-responsive TiO2 films were fabricated via vacuum annealing of the samples where point defects, namely oxygen vacancies and titanium interstitial, are surmised to play a critical role. An ultrafast switching was observed in wetting characteristics of the single crystalline rutile TiO2 films from a hydrophobic state to a superhydrophilic state by single pulsed excimer laser annealing. It was observed that the laser annealing almost doubles the photocatalytic efficiency of the anatase epitaxial thin films. I was able to measure the photochemical properties of the rutile and the anatase TiO2 heterostructures in a controlled way due to the single crystalline nature of the films. Second, the rutile TiO2 epilayers with different out-of-plane orientations were deposited and used as a platform for VO2 based epitaxial heterostructures with the aim of manipulating of microstructure and electrical properties of the VO 2 films. Vanadium dioxide (VO2) is an interesting material due to the abrupt change in electrical resistivity and infrared transmittance at about 68 °C. The transition temperature can be tuned through microstructural engineering. It was the idea behind using rutile TiO2 with different crystallographic orientations as a template to tune the semiconductor to metal transition characteristics of the VO2 top layer. I successfully grew VO2(001), VO2(100), and VO2(2¯01) epitaxial thin films on TiO2(100)/c-sapphire, TiO2(101)/r-sapphire, and TiO2(001)/ m-sapphire platforms, respectively. It was observed that tetragonal phase of VO2 was stabilized at lower temperatures leading to a significant decrease in the semiconductor to metal transition temperature. In other words, we were able to tune the transition temperature of the VO 2 epitaxial heterostructures. This achievement introduces the VO 2 based single crystalline heterostructures as a promising candidate for a wide range of applications where different transition temperatures are required. The epitaxial relationships were established and atomic arrangement across the interfaces was studied in detail.

  9. The self-paced VO2max test to assess maximal oxygen uptake in highly trained runners.

    PubMed

    Hogg, James S; Hopker, James G; Mauger, Alexis R

    2015-03-01

    The novel self-paced maximal-oxygen-uptake (VO2max) test (SPV) may be a more suitable alternative to traditional maximal tests for elite athletes due to the ability to self-regulate pace. This study aimed to examine whether the SPV can be administered on a motorized treadmill. Fourteen highly trained male distance runners performed a standard graded exercise test (GXT), an incline-based SPV (SPVincline), and a speed-based SPV (SPVspeed). The GXT included a plateau-verification stage. Both SPV protocols included 5×2-min stages (and a plateau-verification stage) and allowed for self-pacing based on fixed increments of rating of perceived exertion: 11, 13, 15, 17, and 20. The participants varied their speed and incline on the treadmill by moving between different marked zones in which the tester would then adjust the intensity. There was no significant difference (P=.319, ES=0.21) in the VO2max achieved in the SPVspeed (67.6±3.6 mL·kg(-1)·min(-1), 95%CI=65.6-69.7 mL·kg(-1)·min(-1)) compared with that achieved in the GXT (68.6±6.0 mL·kg(-1)·min(-1), 95%CI=65.1-72.1 mL·kg(-1)·min(-1)). Participants achieved a significantly higher VO2max in the SPVincline (70.6±4.3 mL·kg(-1)·min(-1), 95%CI=68.1-73.0 mL·kg(-1)·min(-1)) than in either the GXT (P=.027, ES=0.39) or SPVspeed (P=.001, ES=0.76). The SPVspeed protocol produces VO2max values similar to those obtained in the GXT and may represent a more appropriate and athlete-friendly test that is more oriented toward the variable speed found in competitive sport.

  10. Effects of gamma irradiations on reactive pulsed laser deposited vanadium dioxide thin films

    NASA Astrophysics Data System (ADS)

    Madiba, I. G.; Émond, N.; Chaker, M.; Thema, F. T.; Tadadjeu, S. I.; Muller, U.; Zolliker, P.; Braun, A.; Kotsedi, L.; Maaza, M.

    2017-07-01

    Vanadium oxide films are considered suitable coatings for various applications such as thermal protective coating of small spacecrafts because of their thermochromic properties. While in outer space, such coating will be exposed to cosmic radiations which include γ-rays. To study the effect of these γ-rays on the coating properties, we have deposited vanadium dioxide (VO2) films on silicon substrates and subjected them to extensive γ-irradiations with typical doses encountered in space missions. The prevalent crystallographic phase after irradiation remains the monoclinic VO2 phase but the films preferential orientation shifts to lower angles due to the presence of disordered regions caused by radiations. Raman spectroscopy measurements also evidences that the VO2 structure is slightly affected by gamma irradiation. Indeed, increasing the gamma rays dose locally alters the crystalline and electronic structures of the films by modifying the V-V inter-dimer distance, which in turns favours the presence of the VO2 metallic phase. From the XPS measurements of V2p and O1s core level spectra, an oxidation of vanadium from V4+ towards V5+ is revealed. The data also reveal a hydroxylation upon irradiation which is corroborated by the vanishing of a low oxidation state peak near the Fermi energy in the valence band. Our observations suggest that gamma radiations induce the formation of Frenkel pairs. Moreover, THz transmission measurements show that the long range structure of VO2 remains intact after irradiation whilst the electrical measurements evidence that the coating resistivity decreases with gamma irradiation and that their transition temperature is slightly reduced for high gamma ray doses. Even though gamma rays are only one of the sources of radiations that are encountered in space environment, these results are very promising with regards to the potential of integration of such VO2 films as a protective coating for spacecrafts.

  11. Ab-initio calculations of structural, electronic, and optical properties of Zn3(VO4)2

    NASA Astrophysics Data System (ADS)

    Ahmed, Nisar; Mukhtar, S.; Gao, Wei; Zafar Ilyas, Syed

    2018-03-01

    The structural, electronic, and optical properties of Zn3(VO4)2 are investigated using full potential linearized augmented plane wave (FP-LAPW) method within the framework of density functional theory (DFT). Various approaches are adopted to treat the exchange and correlation potential energy such as generalized gradient approximation (GGA), GGA+U, and the Tran–Blaha modified Becke–Johnson (TB-mBJ) potential. The calculated band gap of 3.424 eV by TB-mBJ is found to be close to the experimental result (3.3 eV). The optical anisotropy is analyzed through optical constants, such as dielectric function and absorption coefficient along parallel and perpendicular crystal orientations. The absorption coefficient reveals high absorption (1.5× {10}6 {cm}}-1) of photons in the ultraviolet region.

  12. Combined strain and composition-induced effects in the metal-insulator transition of epitaxial VO2 films

    NASA Astrophysics Data System (ADS)

    Théry, V.; Boulle, A.; Crunteanu, A.; Orlianges, J. C.

    2017-12-01

    The role of epitaxial strain, thermal strain, and bulk (strain-free) lattice parameters in the metal-insulator transition (MIT) and the structural phase transition (SPT) of VO2 is investigated for the case of epitaxial films grown on (001)-oriented TiO2 substrates. Temperature-resolved X-ray reciprocal space mapping has been used to determine the absolute state of strain as well as the bulk lattice parameters of VO2 at 100 °C. For the thinnest film (15 nm), the state of strain is dominated by the film/substrate lattice mismatch yielding an in-plane tensile strain which, in turn, shifts both the MIT and the SPT towards lower temperatures. Conversely, for the thickest film (100 nm), the epitaxial strain is relaxed, so that the state of strain is dominated by the VO2/TiO2 thermal expansion mismatch which is responsible for a compressive in-plane strain. In all cases, a swelling of the strain-free VO2 unit-cell is observed which indicates the presence of interfacial oxygen vacancies and/or Ti diffusion into the VO2 films. The presence of oxygen vacancies stabilizes the metallic rutile phase and counterbalances the action of thermal strain on the MIT and the SPT and degrades the electric properties for the thinnest film. For the thickest film, the resistivity ratio is 6.4 × 104.

  13. Preparation and enhanced infrared response properties of ordered W-doped VO2 nanowire array

    NASA Astrophysics Data System (ADS)

    Xie, Bing He; Fu, Wen Biao; Fei, Guang Tao; Xu, Shao Hui; Gao, Xu Dong; Zhang, Li De

    2018-04-01

    In this article, pure and tungsten-doped (W-doped) highly ordered two-dimensional (2D) vanadium dioxide (VO2) nanowire arrays were successfully prepared by a hydrothermal treatment, followed by a self-assembly progress and the in-situ high temperature treatment. The infrared photodetector devices based on monoclinic VO2 (VO2(M)) and W-doped VO2(M) nanowires were comparatively studied . It was found that the device based on W-doped VO2(M) nanowires exhibits a rapid infrared response and an enhanced photoelectric responsivity of 21.4 mA/W under the incident infrared light intensity of 280 mW/cm2, which is nearly two orders of magnitude superior to pure VO2(M) nanowire array. Our experimental results provided a direct and convenient path for design of future high-performance photodetector devices.

  14. Min-By-Min Respiratory Exchange and Oxygen Uptake Kinetics During Steady-State Exercise in Subjects of High and Low Max VO2

    ERIC Educational Resources Information Center

    Weltman, Arthur; Katch, Victor

    1976-01-01

    No statistically meaningful differences in steady-state vo2 uptake for high and low max vo2 groups was indicated in this study, but a clear tendency was observed for the high max vo2 group to reach the steady-state at a faster rate. (MB)

  15. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors

    NASA Astrophysics Data System (ADS)

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-11-01

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm-2 (~548 F g-1) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors.

  16. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors

    PubMed Central

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-01-01

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm−2 (~548 F g−1) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors. PMID:26531072

  17. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors.

    PubMed

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-11-04

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm(-2) (~548 F g(-1)) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors.

  18. Characterization of nanostructured VO2 thin films grown by magnetron controlled sputtering deposition and post annealing method.

    PubMed

    Chen, Sihai; Lai, Jianjun; Dai, Jun; Ma, Hong; Wang, Hongchen; Yi, Xinjian

    2009-12-21

    By magnetron controlled sputtering system, a new nanostructured metastable monoclinic phase VO2 (B) thin film has been fabricated. The testing result shows that this nanostructured VO2 (B) thin film has high temperature coefficient of resistance (TCR) of -7%/K. Scanning electron microscopy measurement shows that the average grain diameter of the VO2 (B) crystallite is between 100 and 250 nm. After post annealed, VO2 (B) crystallite is changed into monoclinic (M) phase VO2 (M) crystallite with the average grain diameter between 20 and 50 nm. A set up of testing the thin film switching time is established. The test result shows the switching time is about 50 ms. With the nanostructured VO2 (B) and VO2 (M) thin films, optical switches and high sensitivity detectors will be presented.

  19. Phase transition in bulk single crystals and thin films of V O 2 by nanoscale infrared spectroscopy and imaging

    DOE PAGES

    Liu, Mengkun; Sternbach, Aaron J.; Wagner, Martin; ...

    2015-06-29

    We have systematically studied a variety of vanadium dioxide (VO 2) crystalline forms, including bulk single crystals and oriented thin films, using infrared (IR) near-field spectroscopic imaging techniques. By measuring the IR spectroscopic responses of electrons and phonons in VO 2 with sub-grain-size spatial resolution (~20nm), we show that epitaxial strain in VO 2 thin films not only triggers spontaneous local phase separations, but leads to intermediate electronic and lattice states that are intrinsically different from those found in bulk. Generalized rules of strain- and symmetry-dependent mesoscopic phase inhomogeneity are also discussed. Furthermore, these results set the stage for amore » comprehensive understanding of complex energy landscapes that may not be readily determined by macroscopic approaches.« less

  20. Flexible thermochromic window based on hybridized VO2/graphene.

    PubMed

    Kim, Hyeongkeun; Kim, Yena; Kim, Keun Soo; Jeong, Hu Young; Jang, A-Rang; Han, Seung Ho; Yoon, Dae Ho; Suh, Kwang S; Shin, Hyeon Suk; Kim, TaeYoung; Yang, Woo Seok

    2013-07-23

    Large-scale integration of vanadium dioxide (VO2) on mechanically flexible substrates is critical to the realization of flexible smart window films that can respond to environmental temperatures to modulate light transmittance. Until now, the formation of highly crystalline and stoichiometric VO2 on flexible substrate has not been demonstrated due to the high-temperature condition for VO2 growth. Here, we demonstrate a VO2-based thermochromic film with unprecedented mechanical flexibility by employing graphene as a versatile platform for VO2. The graphene effectively functions as an atomically thin, flexible, yet robust support which enables the formation of stoichiometric VO2 crystals with temperature-driven phase transition characteristics. The graphene-supported VO2 was capable of being transferred to a plastic substrate, forming a new type of flexible thermochromic film. The flexible VO2 films were then integrated into the mock-up house, exhibiting its efficient operation to reduce the in-house temperature under infrared irradiation. These results provide important progress for the fabrication of flexible thermochromic films for energy-saving windows.

  1. Exertional oxygen uptake kinetics: a stamen of stamina?

    PubMed

    Whipp, Brian J; Rossiter, H B; Ward, S A

    2002-04-01

    The fundamental pulmonary O(2) uptake (.VO(2)) response to moderate, constant-load exercise can be characterized as (d.VO(2)/dt)(tau)+Delta.VO(2) (t)=Delta.VO(2SS) where Delta.VO(2SS) is the steady-state response, and tau is the time constant, with the .VO(2) kinetics reflecting intramuscular O(2) uptake (.QO(2)) kinetics, to within 10%. The role of phosphocreatine (PCr) turnover in .QO(2) control can be explored using (31)P-MR spectroscopy, simultaneously with .VO(2). Although tau.VO(2) and tauPCr vary widely among subjects (approx. 20-65 s), they are not significantly different from each other, either at the on- or off-transient. A caveat to interpreting the "well-fit" exponential is that numerous units of similar Delta.VO(2SS) but with a wide tau distribution can also yield a .VO(2) response with an apparent single tau. This tau is, significantly, inversely correlated with lactate threshold and .VO(2max)(but is poorly predictive; a frail stamen, therefore), consistent with tau not characterizing a compartment with uniform kinetics. At higher intensities, the fundamental kinetics become supplemented with a slowly-developing phase, setting .VO(2)on a trajectory towards maximum .VO(2). This slow component is also demonstrable in Delta[PCr]: the decreased efficiency thereby reflecting a predominantly high phosphate-cost of force production rather than a high O(2)-cost of phosphate production. We also propose that the O(2)-deficit for the slow-component is more likely to reflect shifting Delta.VO(2SS) rather than a single one with a single tau.

  2. The role of postural control in the association between aerobic capacity and walking capacity in chronic stroke: a cross-sectional analysis.

    PubMed

    Outermans, Jacqueline C; van de Port, Ingrid; Kwakkel, Gert; Visser-Meily, Johanna M; Wittink, Harriet

    2018-03-12

    Reports on the association between aerobic capacity and walking capacity in people after stroke show disparate results. To determine (1) if the predictive validity of peak oxygen uptake (VO2peak) for walking capacity post stroke is different from that of maximal oxygen uptake (VO2max) and (2) if postural control, hemiplegic lower extremity muscle strength, age and gender distort the association between aerobic capacity and walking capacity. Cross-sectional study. General community in Utrecht, the Netherlands. Community-dwelling people more than three months after stroke. Measurement of aerobic capacity were performed with cardiopulmonary exercise testing (CPET) and differentiated between the achievement of VO2peak or VO2max. Measurement of walking capacity with the Six Minute Walk Test (6MWT), postural control with the Performance Oriented Mobility Assessment (POMA) and hemiplegic lower extremity muscle strength with the Motricity Index (MI-LE). Fifty-one out of 62 eligible participants, aged 64.7 (±12.5) years were included. Analysis of covariance (ANCOVA) showed a nonsignificant difference between the predictive validities of VO2max (N = 22, β = 0.56; 95%CI 0.12 - 0.97) and VO2peak (N = 29, β = 0.72; 95%CI 0.38 - 0.92). Multiple regression analysis of the pooled sample showed a significant decrease in the β value of VO2peak (21.6%) for the 6MWT when adding the POMA as a covariate in the association model. VO2peak remained significantly related to 6MWT after correcting for the POMA (β = 0.56 (95%CI 0.39 - 0.75)) CONCLUSIONS: The results suggest similar predictive validity of aerobic capacity for walking capacity in participants achieving VO2max compared to those only achieving VO2peak. Postural control confounds the association between aerobic capacity and walking capacity. Aerobic capacity remains a valid predictor of walking capacity. Aerobic capacity is an important factor associated with walking capacity after stroke. However, to understand this relationship, postural control needs to be measured. Both aerobic capacity and postural control may need to be addressed during interventions aiming to improve walking capacity after stroke.

  3. Jumping and hopping in elite and amateur orienteering athletes and correlations to sprinting and running.

    PubMed

    Hébert-Losier, Kim; Jensen, Kurt; Holmberg, Hans-Christer

    2014-11-01

    Jumping and hopping are used to measure lower-body muscle power, stiffness, and stretch-shortening-cycle utilization in sports, with several studies reporting correlations between such measures and sprinting and/or running abilities in athletes. Neither jumping and hopping nor correlations with sprinting and/or running have been examined in orienteering athletes. The authors investigated squat jump (SJ), countermovement jump (CMJ), standing long jump (SLJ), and hopping performed by 8 elite and 8 amateur male foot-orienteering athletes (29 ± 7 y, 183 ± 5 cm, 73 ± 7 kg) and possible correlations to road, path, and forest running and sprinting performance, as well as running economy, velocity at anaerobic threshold, and peak oxygen uptake (VO(2peak)) from treadmill assessments. During SJs and CMJs, elites demonstrated superior relative peak forces, times to peak force, and prestretch augmentation, albeit lower SJ heights and peak powers. Between-groups differences were unclear for CMJ heights, hopping stiffness, and most SLJ parameters. Large pairwise correlations were observed between relative peak and time to peak forces and sprinting velocities; time to peak forces and running velocities; and prestretch augmentation and forest-running velocities. Prestretch augmentation and time to peak forces were moderately correlated to VO(2peak). Correlations between running economy and jumping or hopping were small or trivial. Overall, the elites exhibited superior stretch-shortening-cycle utilization and rapid generation of high relative maximal forces, especially vertically. These functional measures were more closely related to sprinting and/or running abilities, indicating benefits of lower-body training in orienteering.

  4. Facile Approach to Preparing a Vanadium Oxide Hydrate Layer as a Hole-Transport Layer for High-Performance Polymer Solar Cells.

    PubMed

    Cong, Hailin; Han, Dongwei; Sun, Bingbing; Zhou, Dongying; Wang, Chen; Liu, Ping; Feng, Lai

    2017-05-31

    We demonstrate a facile and green approach to preparing a vanadium oxide hydrate (VO x ·nH 2 O) layer to serve as the hole-transport layer (HTL) in high-performance polymer solar cells (PSCs). The VO x ·nH 2 O layer was in situ prepared by a combined H 2 O 2 and ultraviolet-ozone (UVO) processing on a VO x layer. The as-prepared VO x ·nH 2 O layer featured a work function of 5.0 ± 0.1 eV, high transmittance, and better interface properties compared to those of the generally prepared VO x (UVO or thermal annealing) layers. PSCs based on poly[(ethylhexyl-thiophenyl)-benzodithiophene-(ethylhexyl)-thienothiophene]/[6,6]-phenyl-C 71 -butyric acid methyl ester using the VO x ·nH 2 O layer as the HTL yielded high power conversion efficiencies (PCEs) up to 8.11%, outperforming the devices with VO x layers (PCE of 6.79% for the UVO-processed VO x layer and 6.10% for the thermally annealed VO x layer) and conventional polyethylenedioxythiophene-polystyrenesulfonate (PEDOT:PSS) layers (PCE of 7.67%). The improved PCE was attributed to the enhanced J SC and/or fill factor, which mainly correlate to the improved interfacial contact between the photoactive layer and the indium tin oxide/HTL or cathode when using the VO x ·nH 2 O layer as the HTL. A similar improvement in the PCE was also observed for the PSCs based on poly(3-hexylthiophene)/[6,6]-phenyl-C 61 -butyric acid methyl ester. In addition, PSCs with a VO x ·nH 2 O layer as the HTL showed a higher stability than that of those with a PEDOT:PSS layer. Hence, it would be possible to use this simply and in situ prepared VO x ·nH 2 O layer as an inexpensive HTL for high-performance PSCs.

  5. Patterns of Senescence in Human Cardiovascular Fitness: VO2max in Subsistence and Industrialized Populations

    PubMed Central

    Pisor, Anne C.; Gurven, Michael; Blackwell, Aaron D.; Kaplan, Hillard; Yetish, Gandhi

    2014-01-01

    Objectives This study explores whether cardiovascular fitness levels and senescent decline are similar in the Tsimane of Bolivia and Canadians, as well as other subsistence and industrialized populations. Among Tsimane, we examine whether morbidity predicts lower levels and faster decline of cardiovascular fitness, or whether their lifestyle (e.g., high physical activity) promotes high levels and slow decline. Alternatively, high activity levels and morbidity might counterbalance such that Tsimane fitness levels and decline are similar to those in industrialized populations. Methods Maximal oxygen uptake (VO2max) was estimated using a step test heart rate method for 701 participants. We compared these estimates to the Canadian Health Measures Survey and previous studies in industrialized and subsistence populations. We evaluated whether health indicators and proxies for market integration were associated with VO2max levels and rate of decline for the Tsimane. Results The Tsimane have significantly higher levels of VO2max and slower rates of decline than Canadians; initial evidence suggests differences in VO2max levels between other subsistence and industrialized populations. Low hemoglobin predicts low VO2max for Tsimane women while helminth infection predicts high VO2max for Tsimane men, though results might be specific to the VO2max scaling parameter used. No variables tested interact with age to moderate decline. Conclusions The Tsimane demonstrate higher levels of cardiovascular fitness than industrialized populations, but levels similar to other subsistence populations. The high VO2max of Tsimane is consistent with their high physical activity and few indicators of cardiovascular disease, measured in previous studies. PMID:24022886

  6. Highly infrared sensitive VO2 nanowires for a nano-optical device.

    PubMed

    Bhuyan, Prabal Dev; Gupta, Sanjeev K; Kumar, Ashok; Sonvane, Yogesh; Gajjar, P N

    2018-04-25

    Recent studies on the electronic, magnetic and optical properties of VO2 (vanadium dioxide) materials have motivated the exploration of one dimensional VO2 nanowires. First principles calculations were performed to investigate the structural, electronic, magnetic and optical properties of the monoclinic (M) and rutile (R) phases of VO2 nanowires. The monoclinic phase shows semiconducting behaviour with a band gap of 1.17 eV, whereas the rutile phase of VO2 nanowires behaves as a spin gapless semiconducting material, as band lines cross the Fermi level due only to up spin contribution. The monoclinic structure of VO2 nanowires is found to be paramagnetic and the rutile structure shows ferromagnetic half metal behavior. The conductivity calculation for VO2 nanowires shows the metal-insulator transition (MIT) temperature to be 250 K. The possible mechanism of VO2 nanowires to be used as smart windows has been discussed, as the nanowires are highly sensitive in the infrared (IR) region. Interestingly, at low temperature, the VO2 monoclinic structure allows infrared light to be transmitted, while VO2 with the rutile phase blocks light in the IR region. Furthermore, we adsorbed CO2, N2 and SO2 gas molecules on 1D VO2 monoclinic nanowire to investigate their interaction behaviour. It was observed that the absorption and transmission properties of VO2 dramatically change upon the adsorption of CO2 and SO2 gas molecules, which is likely to open up its application as an optical gas sensor.

  7. Structure and enhanced thermochromic performance of low-temperature fabricated VO2/V2O3 thin film

    NASA Astrophysics Data System (ADS)

    Sun, Guangyao; Cao, Xun; Gao, Xiang; Long, Shiwei; Liang, Mengshi; Jin, Ping

    2016-10-01

    For VO2-based smart window manufacture, it is a long-standing demand for high-quality thin films deposited at low temperature. Here, the thermochromic films of VO2 were deposited by a magnetron sputtering method at a fairly low temperature of 250 °C without subsequent annealing by embedding a V2O3 interlayer. V2O3 acts as a seed layer to lower the depositing temperature and buffer layer to epitaxial grow VO2 film. The VO2/V2O3 films display high solar modulating ability and narrow hysteresis loop. Our data can serve as a promising point for industrial production with high degree of crystallinity at a low temperature.

  8. [Is physical activity an elixir?].

    PubMed

    Lacza, Gyöngyvér; Radák, Zsolt

    2013-05-19

    Physical exercise has systemic effects, and it can regulate all the organs. The relative maximal aerobic oxygen uptake (VO2max) could have been important in the evolution of humans, since higher VO2max meant better hunting abilities for the Stone Age man. However, it appears that high level of VO2max is also important today, in the 21st century to prevent cardiovascular diseases, cancer and neurodegenerative diseases. High level of VO2max is not just preventive against a wide spectrum of diseases, but it associated with better function of many organs. Relevant data suggest that high level of VO2max is a key factor in prevention of diseases and survival even at the modern civilized world.

  9. Structure and enhanced thermochromic performance of low-temperature fabricated VO 2/V 2O 3 thin film

    DOE PAGES

    Sun, Guangyao; Cao, Xun; Gao, Xiang; ...

    2016-10-06

    For VO 2-based smart window manufacture, it is a long-standing demand for high-quality thin films deposited at low temperature. In this paper, the thermochromic films of VO 2 were deposited by a magnetron sputtering method at a fairly low temperature of 250 °C without subsequent annealing by embedding a V 2O 3 interlayer. V 2O 3 acts as a seed layer to lower the depositing temperature and buffer layer to epitaxial grow VO 2 film. The VO 2/V 2O 3 films display high solar modulating ability and narrow hysteresis loop. Finally, our data can serve as a promising point formore » industrial production with high degree of crystallinity at a low temperature.« less

  10. Electronic structure of HxVO2 probed with in-situ spectroscopic ellipsometry

    NASA Astrophysics Data System (ADS)

    Kim, So Yeun; Sandilands, Luke J.; Kang, Taedong; Son, Jaeseok; Sohn, C. H.; Yoon, Hyojin; Son, Junwoo; Moon, S. J.; Noh, T. W.

    Vanadium dioxide (VO2) undergoes a metal-to-insulator transition (MIT) near 340K. Despite extensive studies on this material, the role of electron-electron correlation and electron-lattice interactions in driving this MIT is still under debate. Recently, it was demonstrated that hydrogen can be reversibly absorbed into VO2 thin film without destroying the lattice framework. This H-doping allows systematic control of the electron density and lattice structure which in turn leads to a insulator (VO2) - metal (HxVO2) - insulator (HVO2) phase modulation. To better understand the phase modulation of HxVO2, we used in-situ spectroscopic ellipsometry to monitor the electronic structure during the hydrogenization process, i.e. we measured the optical conductivity of HxVO2 while varying x. Starting in the high temperature rutile metallic phase of VO2, we observed a large change in the electronic structure upon annealing in H gas at 370K: the low energy conductivity is continuously suppressed, consistent with reported DC resistivity data, while the conductivity peaks at high energy show strong changes in energy and spectral weight. The implications of our results for the MIT in HxVO2 will be discussed.

  11. High-intensity Interval Training in Different Exercise Modes: Lessons from Time to Exhaustion.

    PubMed

    Sousa, Ana Catarina; Fernandes, Ricardo J; Boas, Joao Paulo Vilas; Figueiredo, Pedro

    2018-06-20

    To provide information for high-intensity interval training (HIIT) load, we compared the temporal variables of VO 2 response at, and after, a time sustained at the exercise intensity corresponding to VO 2max (Tlim) in different exercise modes. Forty-five trained male swimmers (11), rowers (13), runners (10) and cyclists (11) completed an incremental protocol to determine the velocity (vVO 2max ) or power (wVO 2max ) at VO 2max and a square wave exercise from rest to 100% of vVO 2max /wVO 2max . The temporal variables of VO 2 response were examined using a breath-by-breath gas analyzer. VO 2 responses were not different between exercise modes, except for the percentage of VO 2max at 50% of Tlim, which was ~6% higher in rowing compared to cycling (97.70±2.90 vs 92.40±5.69%, p =0.013). During the recovery period, both swimmers and rowers evidenced higher percentages of VO 2max compared to cyclists at 30 s (65.1±10.4 and 65.7±5.6 vs 52.7±5.6%) and 60 s (41.7±10.8 and 38.4±5.4 vs 30.4±1.8%) time periods, all for p< 0.01. Furthermore, swimmers presented higher time values to reach 50% VO 2max compared to runners and cyclists (51.1±15.6 vs 38.1±6.7 and 33.8±4.7%; p <0.001). When training at 100% of VO 2max intensity, fixed intervals for HIIT could be set freely. However, recovery periods based on time or intensity are exercise-mode dependent. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Rapid hydrothermal synthesis of VO2 (B) and its conversion to thermochromic VO2 (M1).

    PubMed

    Popuri, Srinivasa Rao; Miclau, Marinela; Artemenko, Alla; Labrugere, Christine; Villesuzanne, Antoine; Pollet, Michaël

    2013-05-06

    The present study provides a rapid way to obtain VO2 (B) under economical and environmentally friendly conditions. VO2 (B) is one of the well-known polymorphs of vanadium dioxide and is a promising cathode material for aqueous lithium ion batteries. VO2 (B) was successfully synthesized by rapid single-step hydrothermal process using V2O5 and citric acid as precursors. The present study shows that phase-pure VO2 (B) polytype can be easily obtained at 180 °C for 2 h and 220 °C for 1 h, that is, the lowest combination of temperature and duration reported so far. The obtained VO2 (B) is characterized by X-ray powder diffraction, high-resolution scanning electron microscopy, and Fourier transform infrared spectroscopy. In addition, we present an indirect way to obtain VO2 (M1) by annealing VO2 (B) under vacuum for 1 h.

  13. Li2.97Mg0.03VO4: High rate capability and cyclability performances anode material for rechargeable Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Dong, Youzhong; Zhao, Yanming; Duan, He; Singh, Preetam; Kuang, Quan; Peng, Hongjian

    2016-07-01

    Mg-doped composite, Li2.97Mg0.03VO4, with an orthorhombic structure was prepared by a sol-gel method. The effects of the Mg doping on the structure and electrochemical performance of Li3VO4 were investigated. The X-ray diffraction pattern shows that the Mg doping does not change the crystal structure of Li3VO4. The EDS mappings indicated the fairly uniform distribution of Mg throughout the grains of Li2.97Mg0.03VO4. Electronic conductivity of Mg-doped Li3VO4 increased by two orders of magnitude compared to that of pure Li3VO4. CV and EIS measurement confirms that the Li2.97Mg0.03VO4 sample exhibits a smaller polarization and transfer resistance and a higher lithium diffusion coefficient compared with the pure Li3VO4. Due to the better electrochemical kinetics properties, Mg-doped Li3VO4 showed a significant improved performance compared to the pure Li3VO4, especially for the high rate capability. At the higher discharge/charge rate (2C), the discharge and charge capacities of 415.5 and 406.1 mAh/g have been obtained for the Li2.97Mg0.03VO4 which is more than three times higher the discharge/charge capacities of Li3VO4. The discharge and charge capacities of pure Li3VO4 are only 126.4 and 125.8 mAh/g respectively. The excellent electrochemical performance of Li2.97Mg0.03VO4 enables it as a promising anode material for rechargeable lithium-ion batteries.

  14. Aerobic Fitness Level Typical of Elite Athletes is not Associated With Even Faster VO2 Kinetics During Cycling Exercise

    PubMed Central

    Figueira, Tiago R.; Caputo, Fabrizio; Machado, Carlos E.P.; Denadai, Benedito S.

    2008-01-01

    The aim of this study was to address the question if the VO2 kinetics is further improved as the aerobic training status increases from trained to elite level athletes. Maximal oxygen uptake (VO2max), work-rate associated to VO2max (IVO2max) and VO2 kinetics of moderate (Mod) and maximal exercise (Max) were determined in fifty- five subjects. Then, they were assigned into three groups: low (LF), intermediate (IF) and high (HF) aerobic fitness level. In average, the VO2max of LF, IF and HF groups were, respectively, 36.0 ± 3.1, 51.1 ± 4.5 and 68.1 ± 3.9 ml·kg·min-1 (p ≤ 0.05 among each other). VO2 kinetics mean response time of both exercise intensities were significantly faster (p ≤ 0.05) in HF (Mod, 27.5 ± 5.5 s; Max, 32.6 ± 8.3 s) and IF (Mod, 25.0 ± 3.1 s; Max, 42.6 ± 10.4 s) when compared to LF (Mod, 35.7 ± 7.9 s; Max: 57.8 ± 17.8 s). We can conclude that VO2 kinetics is improved as the fitness level is increased from low to intermediate but not further improved as the aerobic fitness level increases from intermediate to high. Key points Currently, it is reasonable to believe that the rate-limiting step of VO2 kinetics depends on exercise intensity. The well known physiological adaptations induced by endurance training are likely the most extreme means to overcome rate-limiting steps determining VO2 kinetics across exercise intensities. However, exercise adaptation leading individuals to the high-end of aerobic fitness level range (VO2max > 65 ml.kg.min-1) is not able to further improve VO2 kinetics during both, moderate and maximal intensity exercise. PMID:24150145

  15. Physiologic responses during indoor cycling.

    PubMed

    Battista, Rebecca A; Foster, Carl; Andrew, Jessica; Wright, Glenn; Lucia, Alejandro; Porcari, John P

    2008-07-01

    During the last decade, there has been active interest in indoor cycling (e.g., spinning) as a method of choreographed group exercise. Recent studies have suggested that exercise intensity during indoor cycling may be quite high and may transiently exceed Vo2max. This study sought to confirm these findings, as the apparent high intensity of indoor cycling has implications for both the efficacy and the risk of indoor cycling as an exercise method. Twenty healthy female students performed an incremental exercise test to define Vo2max and performed 2 videotaped indoor exercise classes lasting 45 minutes and 35 minutes. Vo2, heart rate (HR), and rating of perceived exertion (RPE) were measured during the indoor cycling classes, with Vo2 data integrated in 30-second intervals. The mean %Vo2max during the indoor cycling classes was modest (74 +/- 14% Vo2max and 66 +/- 14%Vo2max, respectively). However, 52% and 35% of the time during the 45- and 35-minute classes was spent at intensities greater than the ventilatory threshold (VT). The HR response indicated that 35% and 38% of the session time was above the HR associated with VT. In 10 of the 40 exercise sessions, there were segments in which the momentary Vo2 exceeded Vo2max observed during incremental testing, and the cumulative time with exercise intensity greater than Vo2max ranged from 0.5 to 14.0 minutes. It can be concluded that although the intensity of indoor cycling in healthy, physically active women is moderate, there are frequent observations of transient values of Vo2 exceeding Vo2max, and a substantial portion of the exercise bouts at intensities greater than VT. As such, the data suggest that indoor cycling must be considered a high-intensity exercise mode of exercise training, which has implications for both efficacy and risk.

  16. Flexible 3D Fe@VO2 core-shell mesh: A highly efficient and easy-recycling catalyst for the removal of organic dyes.

    PubMed

    Li, Jing; Wang, Ruoqi; Su, Zhen; Zhang, Dandan; Li, Heping; Yan, Youwei

    2018-10-01

    Nowadays, it is extremely urgent to search for efficient and effective catalysts for water purification due to the severe worldwide water-contamination crises. Here, 3D Fe@VO 2 core-shell mesh, a highly efficient catalyst toward removal of organic dyes with excellent recycling ability in the dark is designed and developed for the first time. This novel core-shell structure is actually 304 stainless steel mesh coated by VO 2 , fabricated by an electrophoretic deposition method. In such a core-shell structure, Fe as the core allows much easier separation from the water, endowing the catalyst with a flexible property for easy recycling, while VO 2 as the shell is highly efficient in degradation of organic dyes with the addition of H 2 O 2 . More intriguingly, the 3D Fe@VO 2 core-shell mesh exhibits favorable performance across a wide pH range. The 3D Fe@VO 2 core-shell mesh can decompose organic dyes both in a light-free condition and under visible irradiation. The possible catalytic oxidation mechanism of Fe@VO 2 /H 2 O 2 system is also proposed in this work. Considering its facile fabrication, remarkable catalytic efficiency across a wide pH range, and easy recycling characteristic, the 3D Fe@VO 2 core-shell mesh is a newly developed high-performance catalyst for addressing the universal water crises. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Effects of V2O3 buffer layers on sputtered VO2 smart windows: Improved thermochromic properties, tunable width of hysteresis loops and enhanced durability

    NASA Astrophysics Data System (ADS)

    Long, Shiwei; Cao, Xun; Sun, Guangyao; Li, Ning; Chang, Tianci; Shao, Zewei; Jin, Ping

    2018-05-01

    Vanadium dioxide (VO2) is one of the most well-known thermochromic materials, which exhibits a notable optical change from transparent to reflecting in the infrared region upon a metal-insulator phase transition. For practical applications, VO2 thin films should be in high crystalline quality to obtain a strong solar modulation ability (ΔTsol). Meanwhile, narrow hysteresis loops and robust ambient durability are also indispensable for sensitivity and long-lived utilization, respectively. In this work, a series of high-quality V2O3/VO2 bilayer structures were grown on quartz glass substrates by reactive magnetron sputtering. Basically, the bottom V2O3 acts as the buffer layer to improve the crystallinity of the top VO2, while the VO2 serves as the thermochromic layer to guarantee the solar modulation ability for energy-saving. We observed an obvious increase in ΔTsol of 76% (from 7.5% to 13.2%) for VO2 films after introducing V2O3 buffer layers. Simultaneously, a remarkable reduction by 79% (from 21.9 °C to 4.7 °C) in width of hysteresis loop was obtained when embedding 60 nm V2O3 buffer for 60 nm VO2. In addition, VO2 with non-stoichiometry of V2O3±x buffer demonstrates a broadening hysteresis loops width, which is derived from the lattice distortion caused by lattice imperfection. Finally, durability of VO2 has been significantly improved due to positive effects of V2O3 buffer layer. Our results lead to a comprehensive enhancement in crystallinity of VO2 and shed new light on the promotion of thermochromic property by homologous oxides for VO2.

  18. Hydrothermal growth of VO2 nanoplate thermochromic films on glass with high visible transmittance

    PubMed Central

    Zhang, Jiasong; Li, Jingbo; Chen, Pengwan; Rehman, Fida; Jiang, Yijie; Cao, Maosheng; Zhao, Yongjie; Jin, Haibo

    2016-01-01

    The preparation of thermochromic vanadium dioxide (VO2) films in an economical way is of interest to realizing the application of smart windows. Here, we reported a successful preparation of self-assembly VO2 nanoplate films on TiO2-buffered glass by a facile hydrothermal process. The VO2 films composed of triangle-shaped plates standing on substrates exhibit a self-generated porous structure, which favors the transmission of solar light. The porosity of films is easily controlled by changing the concentration of precursor solutions. Excellent thermochromic properties are observed with visible light transmittance as high as 70.3% and solar modulating efficiency up to 9.3% in a VO2 film with porosity of ~35.9%. This work demonstrates a promising technique to promote the commercial utilization of VO2 in smart windows. PMID:27296772

  19. Synthesis and characterization of self-bridged silver vanadium oxide/CNTs composite and its enhanced lithium storage performance.

    PubMed

    Liang, Liying; Liu, Haimei; Yang, Wensheng

    2013-02-07

    The improvement of the electrochemical properties of electrode materials with large capacity and good capacity retention is becoming an important task in the field of lithium ion batteries (LIBs). We designed a function-oriented hybrid material consisting of silver vanadium oxide (β-AgVO(3)) nanowires modified with uniform Ag nanoparticles and multi-walled carbon nanotubes (CNTs) as a high-performance cathode material for LIBs. The Ag nanoparticles which precipitated automatically in the synthetic process act as a bridge between the β-AgVO(3) nanowires and CNTs, creating a self-bridged network structure. The Ag particles at the junction of the nanowires and CNTs facilitate electron transport from the CNTs to the nanowires, and thereby improve the electrical conductivity of the β-AgVO(3) nanowires and the composite. Moreover, the self-bridged network is hierarchically porous with a high surface area. When used as a cathode material, this composite electrode reveals high discharge capacities, excellent rate capability, and good cycling stability. The improved performance of the composite arises from its unique nanosized β-AgVO(3) nanowires with short diffusion pathway for lithium ions, efficient electron collection and transfer in the presence of Ag nanoparticles, together with excellent electrical conductivity of CNTs.

  20. Prediction of maximal oxygen uptake by bioelectrical impedance analysis in overweight adolescents.

    PubMed

    Roberts, M D; Drinkard, B; Ranzenhofer, L M; Salaita, C G; Sebring, N G; Brady, S M; Pinchbeck, C; Hoehl, J; Yanoff, L B; Savastano, D M; Han, J C; Yanovski, J A

    2009-09-01

    Maximal oxygen uptake (VO(2max)), the gold standard for measurement of cardiorespiratory fitness, is frequently difficult to assess in overweight individuals due to physical limitations. Reactance and resistance measures obtained from bioelectrical impedance analysis (BIA) have been suggested as easily obtainable predictors of cardiorespiratory fitness, but the accuracy with which ht(2)/Z can predict VO(2max) has not previously been examined in overweight adolescents. The impedance index was used as a predictor of VO(2max) in 87 overweight girls and 47 overweight boys ages 12 to 17 with mean BMI of 38.6 + or - 7.3 and 42.5 + or - 8.2 in girls and boys respectively. The Bland Altman procedure assessed agreement between predicted and actual VO(2max). Predicted VO(2max) was significantly correlated with measured VO(2max) (r(2)=0.48, P<0.0001). Using the Bland Altman procedure, there was significant magnitude bias (r(2)=0.10; P<0.002). The limits of agreement for predicted relative to actual VO(2max) were -589 to 574 mL O(2)/min. The impedance index was highly correlated with VO(2max) in overweight adolescents. However, using BIA data to predict maximal oxygen uptake over-predicted VO(2max) at low levels of oxygen consumption and under-predicted VO(2max) at high levels of oxygen consumption. This magnitude bias, along with the large limits of agreement of BIA-derived predicted VO(2max), limit its usefulness in the clinical setting for overweight adolescents.

  1. Applied physiology of marathon running.

    PubMed

    Sjödin, B; Svedenhag, J

    1985-01-01

    Performance in marathon running is influenced by a variety of factors, most of which are of a physiological nature. Accordingly, the marathon runner must rely to a large extent on a high aerobic capacity. But great variations in maximal oxygen uptake (VO2 max) have been observed among runners with a similar performance capacity, indicating complementary factors are of importance for performance. The oxygen cost of running or the running economy (expressed, e.g. as VO2 15 at 15 km/h) as well as the fractional utilisation of VO2 max at marathon race pace (%VO2 Ma X VO2 max-1) [where Ma = mean marathon velocity] are additional factors which are known to affect the performance capacity. Together VO2 max, VO2 15 and %VO2 Ma X VO2 max-1 can almost entirely explain the variation in marathon performance. To a similar degree, these variables have also been found to explain the variations in the 'anaerobic threshold'. This factor, which is closely related to the metabolic response to increasing exercise intensities, is the single variable that has the highest predictive power for marathon performance. But a major limiting factor to marathon performance is probably the choice of fuels for the exercising muscles, which factor is related to the %VO2 Ma X VO2 max-1. Present indications are that marathon runners, compared with normal individuals, have a higher turnover rate in fat metabolism at given high exercise intensities expressed both in absolute (m/sec) and relative (%VO2 max) terms. The selection of fat for oxidation by the muscles is important since the stores of the most efficient fuel, the carbohydrates, are limited. The large amount of endurance training done by marathon runners is probably responsible for similar metabolic adaptations, which contribute to a delayed onset of fatigue and raise the VO2 Ma X VO2max-1. There is probably an upper limit in training kilometrage above which there are no improvements in the fractional utilisation of VO2 max at the marathon race pace. The influence of training on VO2 max and, to some extent, on the running economy appears, however, to be limited by genetic factors.

  2. Magnetic and Ferroelectric Anisotropy in Multiferroic FeVO4

    NASA Astrophysics Data System (ADS)

    Abdelhamid, Ehab; Dixit, Ambesh; Kimura, Kenta; Kimura, Tsuyoshi; Jayakumar, Onattu; Naik, Vaman; Naik, Ratna; Lawes, Gavin; Nadgorny, Boris

    FeVO4 has been studied as a model system for understanding the magnetoelectric interaction mechanisms in low symmetry multiferroics. Triclinic FeVO4 is characterized by two antiferromagnetic phase transitions, occurring at TN 1 = 22 K and TN 2 = 15 K, with the latter transition signaling a break in the space inversion symmetry, accompanied by the development of a non-collinear magnetic order which induces ferroelectricity. Earlier measurements on polycrystalline FeVO4 doped with magnetic (Cr and Mn) as well as non magnetic (Zn) dopants indicate the stability of the two antiferromagnetic transition temperatures. In this work, single crystals of both undoped and doped FeVO4 were grown from flux. To track the changes in lattice parameters induced by changing the doping concentration (measured by EDAX), XRD and Raman spectra were obtained. By recording the magnetization along two different crystal orientations, we were able to confirm the easy magnetic axis in this structure. Finally, we obtain the crystal's ferroelectric polarization along two different directions in an attempt to further understand the mechanism responsible for the ferroelectric transition. This work is supported by the NSF under DMR-1306449.

  3. IR studies of the impact of Ge doping on the successive conversion of VOn defects in Czochralski-Si containing carbon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Andrianakis, A.; Sgourou, E. N.; Emtsev, V. V.; Ohyama, H.

    2011-02-01

    We report infrared absorption studies of oxygen-related defects in electron-irradiated Ge-doped Czochralski-Si. Our investigation was mainly focused on the reaction channel leading to the formation of VOn (1≤n≤6) defects. The VOn defects form mainly upon annealing, as a result of the successive aggregation of oxygen atoms in the initial VO defect produced by the irradiation: (VO+Oi→VO2+Oi→VO3+Oi→VO4,…). It was found that the ratio of the conversion of VOn to VOn+1 defects is sensitive to the Ge content of the material. In particular, the ratio of the conversion of the VO to the VO2 defects was found to decrease with the increase in Ge concentration of the samples, although the opposite trend was observed for the VO3 to VO4 conversion. However, the VO2 to VO3 conversion changes only slightly with Ge content, being practically unaffected for Ge concentrations up to 2×1020 cm-3. In the case of VO2 formation, the phenomenon was attributed to the elastic strains induced in the lattice due to the Ge presence which affects the balance between the reactions VO+Oi→VO2, VO+SiI→Oi, mainly involved in the decay of the VO and the growth of the VO2 defects. In the case of VO4 formation, the phenomenon was discussed by taking into account the enhancement of the diffusivity of the Oi atoms in the Ge-doped Si, which could lead to an enhancement of the rate of the reaction VO3+Oi→VO4. For the VO3 formation this effect is practically negligible due to the fact that at the temperatures of VO2 to VO3 conversion oxygen diffusivity is quite small. The exhibited behavior in the conversion of the VOn to VOn+1 defects (n=1,2,3) was similar in Ge-doped samples with low carbon content ([Cs]<2×1016 cm-3) and in Ge-doped samples with high carbon content ([Cs]≥1×1017 cm-3). The impact of C as well as its role in the conversion efficiency of VO to VO2 was studied by comparing the spectra in low carbon and high carbon Ge free Si material. Furthermore, a pair of bands at (1037,1051 cm-1) was attributed to the VO5 defect. The origin of another pair of bands (967,1005 cm-1) was discussed and tentatively correlated with a VOnCs structure. The role of Ge and C in the formation of the latter two pairs of bands was discussed.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Hongjiang; Gao, Yanfeng, E-mail: gaosic@gmail.com; School of Materials Science and Engineering, Shanghai University, Shangda Rd. 99, Baoshan, Shanghai 200444

    A novel, hydrothermal and hard-template-free method was developed for the first time to grow oriented, single-crystalline monoclinic VO{sub 2} (B) flower-like nanorod films on transparent conductive fluorine-doped tin oxide (FTO) substrates. The length and morphology of the nanorods can be tuned by changing the growth parameters, such as growth time and initial precursor concentration. The flower-like V{sub 2}O{sub 5} films were obtained after post-calcination treatment of VO{sub 2} (B) films. The photocatalytic activity of V{sub 2}O{sub 5} films was investigated by the degradation of methylene blue (MB) under UV and visible light. The prepared V{sub 2}O{sub 5} film exhibited goodmore » photocatalytic performance (74.6% and 63% under UV and visible light for 210 min, respectively) and more practical application in industry. - Graphical abstract: Flower nanostructured vanadium oxide film was prepared by hydrothermal reaction for photocatalysis application. - Highlights: • Monoclinic VO{sub 2} nanorod array and flower-like nanostructure were directly grown on FTO substrate by hydrothermal reaction. • The growth mechanism was analyzed by FESEM at different time. • V{sub 2}O{sub 5} flower-like nanostructure film was obtained after calcining VO{sub 2} film. • V{sub 2}O{sub 5} film exhibited good light activity and potential application in photocatalysis.« less

  5. Integration of the physiological factors determining endurance performance ability.

    PubMed

    Coyle, E F

    1995-01-01

    This model is used to understand the interrelationships of the physiological factors determining endurance performance ability during prolonged exercise. Early studies found that marathon runners maintain a velocity in competition that corresponds to the intensity at which lactate begins to accumulate in blood and muscle [7, 8, 19]. From this observation, the concept developed that this blood lactate threshold (LT Vo2) reflects the degree of muscular stress, glycogenolysis and fatigue. However, it was not clear whether the lactate accumulation was a result of cardiovascular limitations linked to oxygen delivery, as reflected by Vo2max [54], as opposed to metabolic factors in the exercising muscle related to the extent to which mitochondrial respiration is disturbed to maintain a given rate of O2 consumption [29, 30]. Two studies were performed to determine whether LT Vo2 was tightly coupled to Vo2max. In one study, endurance-trained ischemic heart disease patients were observed to possess a Vo2max that was 18% below that of normal master athletes who followed the patient's training program and who displayed the same performance ability as the patients. Both the patients and the normal men displayed an identical LT Vo2 (i.e., 37 ml/kg/min) (Fig. 2.5). Therefore, performance was determined primarily by LT Vo2 instead of Vo2max in this situation, albeit with abnormal subjects. In a second study we assembled two groups of competitive cyclists who were identical in Vo2max but differed by having a high or low LT Vo2 (82% vs. 66% Vo2max) [13]. When cycling at 80-88% Vo2max, the low LT group displayed more than a 2-fold higher rate of muscle glycogen use and blood lactate concentration, and as a result were able to exercise only one-half as long as the high LT group. Performance time for a given Vo2 was clearly related to LT Vo2 instead of Vo2max (Fig. 2.6). This is not to say that Vo2max plays no role in determining LT Vo2, because as in heart disease patients, it clearly sets the upper limit. Indeed, we have seen that much of the variance (i.e., 31-72%) in LT Vo2 is related to Vo2max. (Fig. 2.11.) However, improvements in performance after the first 2-3 yr of intense training are associated with improvements in LT Vo2, whereas Vo2max generally increases very little thereafter (Table 2.3). The next question concerns the factors responsible for further increases in LT Vo2 and Performance. Another major factor determining LT Vo2 is the muscle's Aerobic Enzyme Activity or mitochondrial respiratory capacity, as discussed in previous reviews [29, 30].(ABSTRACT TRUNCATED AT 400 WORDS)

  6. Effects of Alcohol on Performance on a Distraction Task During Simulated Driving

    PubMed Central

    Allen, Allyssa J.; Meda, Shashwath A.; Skudlarski, Pawel; Calhoun, Vince; Astur, Robert; Ruopp, Kathryn C.; Pearlson, Godfrey D.

    2009-01-01

    Background Prior studies report that accidents involving intoxicated drivers are more likely to occur during performance of secondary tasks. We studied this phenomenon, using a dual-task paradigm, involving performance of a visual oddball (VO) task while driving in an alcohol challenge paradigm. Previous functional MRI (fMRI) studies of the VO task have shown activation in the anterior cingulate, hippocampus, and prefrontal cortex. Thus, we predicted dose-dependent decreases in activation of these areas during VO performance. Methods Forty healthy social drinkers were administered 3 different doses of alcohol, individually tailored to their gender and weight. Participants performed a VO task while operating a virtual reality driving simulator in a 3T fMRI scanner. Results Analysis showed a dose-dependent linear decrease in Blood Oxygen Level Dependent activation during task performance, primarily in hippocampus, anterior cingulate, and dorsolateral prefrontal areas, with the least activation occurring during the high dose. Behavioral analysis showed a dose-dependent linear increase in reaction time, with no effects associated with either correct hits or false alarms. In all dose conditions, driving speed decreased significantly after a VO stimulus. However, at the high dose this decrease was significantly less. Passenger-side line crossings significantly increased at the high dose. Conclusions These results suggest that driving impairment during secondary task performance may be associated with alcohol-related effects on the above brain regions, which are involved with attentional processing/decision-making. Drivers with high blood alcohol concentrations may be less able to orient or detect novel or sudden stimuli during driving. PMID:19183133

  7. Physiological and biological factors associated with a 24 h treadmill ultra-marathon performance.

    PubMed

    Millet, G Y; Banfi, J C; Kerherve, H; Morin, J B; Vincent, L; Estrade, C; Geyssant, A; Feasson, L

    2011-02-01

    The purpose of this study was to examine the physiological and biological factors associated with ultra-endurance performance. Fourteen male runners volunteered to run on a treadmill as many kilometers as possible over a 24-h period (24TR). Maximal oxygen uptake (VO(2max)), velocity associated with VO(2max)(VO(2max)) and running economy (RE) at 8 km/h were measured. A muscle biopsy was also performed in the vastus lateralis muscle. The subjects ran 149.2 ± 15.7 km in 18 h 39 ± 41 min of effective attendance on the treadmill, corresponding to 39.4 ± 4.2% of . Standard multiple-regression analysis showed that performance was significantly (R(2) = 0.82; P = 0.005) related to VO(2max) and specific endurance, i.e. the average speed sustained over the 24TR expressed in . VO(2max) was associated with a high capillary tortuosity (R(2) = 0.66; P = 0.01). Specific endurance was significantly related to RE and citrate synthase activity. It is concluded that a high VO(2max) and an associated developed capillary network are essential for ultra-endurance running performance. The ability to maintain a high %VO(2max) over a 24TR is another factor associated with performance and is mainly related to RE and high mitochondrial oxidative capacity in the vastus lateralis. © 2009 John Wiley & Sons A/S.

  8. Normalization for peak oxygen uptake increases the prognostic power of the ventilatory response to exercise in patients with chronic heart failure.

    PubMed

    Guazzi, Marco; De Vita, Stefano; Cardano, Paola; Barlera, Simona; Guazzi, Maurizio D

    2003-09-01

    Peak exercise oxygen uptake (peak VO2) and ventilation to CO2 production (VE/VCO2) slope are established prognostic indicators in patients with chronic heart failure (CHF). A high VE/VCO2 slope, however, does not take into account the level of physical performance as expressed by peak VO2. We hypothesized that the prognostic value of a high VE/VCO2 slope may be improved by normalization for peak VO2 (VE/VCO2/VO2). One hundred patients with CHF underwent pulmonary function tests at rest (spirometry and lung diffusion capacity) and maximal cardiopulmonary exercise testing. The prognostic value of VE/VCO2 slope, peak VO2 and VE/VCO2/VO2 was probed prospectively. Twenty-one patients died from cardiac reasons during a mean follow-up of 26 +/- 19 months. Nonsurvivors, compared to survivors, showed a lower peak VO2 (13.6 +/- 4.0 vs 17.5 +/- 4.1 mL x min(-1) x kg(-1), P <.01) and a steeper VE/VCO2 slope (43 +/- 11 vs 31.6 +/- 5.0, P <.01). Nonetheless, in patients whose VE/VCO2 slope exceeded 34 (upper normal limit), there was no correlation with peak VO2 (r = -35, P = not significant). Interestingly 35% of them showed a normal exercise performance (peak VO2 > or =18 mL x min(-1) x kg(-1)). At multivariate analysis, the VE/VCO2 slope showed a prognostic power stronger than that of peak VO2; however, the VE/VCO2/VO2 index retained a prognostic power greater than that of both VE/VCO2 slope and peak VO2. A VE/VCO2/VO2 > or =2.4 signaled cases at higher risk. Discrepancies between VE/VCO2 slope and peak VO2 may generate uncertainty. Normalization of the former by the latter improves outcome prediction and may be considered a simple and effective way for maximizing the clinical applicability of these 2 indicators.

  9. Individual Variability in Aerobic Fitness Adaptations to 70-d of Bed Rest and Exercise Training

    NASA Technical Reports Server (NTRS)

    Downs, Meghan; Buxton, Roxanne; Goetchius, Elizabeth; DeWitt, John; Ploutz-Snyder, Lori

    2016-01-01

    Change in maximal aerobic capacity (VO2pk) in response to exercise training and disuse is highly variable among individuals. Factors that could contribute to the observed variability (lean mass, daily activity, diet, sleep, stress) are not routinely controlled in studies. The NASA bed rest (BR) studies use a highly controlled hospital based model as an analog of spaceflight. In this study, diet, hydration, physical activity and light/dark cycles were precisely controlled and provided the opportunity to investigate individual variability. PURPOSE. Evaluate the contribution of exercise intensity and lean mass on change in VO2pk during 70-d of BR or BR + exercise. METHODS. Subjects completed 70-d of BR alone (CON, N=9) or BR + exercise (EX, N=17). The exercise prescription included 6 d/wk of aerobic exercise at 70 - 100% of max and 3 d/wk of lower body resistance exercise. Subjects were monitored 24 hr/d. VO2pk and lean mass (iDXA) were measured pre and post BR. ANOVA was used to evaluate changes in VO2pk pre to post BR. Subjects were retrospectively divided into high and low responders based on change in VO2pk (CON > 20% loss, n=5; EX >10% loss, n=4, or 5% gain, n=4) to further understand individual variability. RESULTS. VO2pk decreased from pre to post BR in CON (P<0.05) and was maintained in EX; however, significant individual variability was observed (CON: -22%, range: -39% to -.5%; EX: -1.8%, range: -16% to 12.6%). The overlap in ranges between groups included 3 CON who experienced smaller reduction in VO2pk (<16%) than the worst responding EX subjects. Individual variability was maintained when VO2pk was normalized to lean mass (range, CON: -33.7% to -5.7%; EX: -15.8% to 11%), and the overlap included 5 CON with smaller reductions in VO2pk than the worst responding EX subjects. High responders to disuse also lost the most lean mass; however, this relationship was not maintained in EX (i.e. the largest gains/losses in lean mass were observed in both high and low responders). Change in VO2pk was not related to exercise intensity. CONCLUSION. Change in VO2pk in response to disuse and exercise was highly variable among individuals, even in this tightly controlled study. Loss in lean mass accounts for a significant degree of variability in the CON; however, training induced gains in VO2pk appear unrelated to lean mass or exercise intensity.

  10. Microstructure evolution determined by the crystalline phases competition in self-assembled WO3-BiVO4 hetero nanostructures

    NASA Astrophysics Data System (ADS)

    Song, Haili; Li, Chao; Nguyen Van, Chien; Dong, Wenxia; Qi, Ruijuan; Zhang, Yuanyuan; Huang, Rong; Chu, Ying-Hao; Duan, Chun-Gang

    2018-02-01

    A series of self-assembled WO3-BiVO4 nanostructured thin films were grown on the (001) yttria-stabilized zirconia (YSZ) substrate at the substrate temperatures of 400 °C, 500 °C, 550 °C, 600 °C, 650 °C and 700 °C by a pulsed laser deposition method. The microstructures including crystalline phases, epitaxial relationships, surface morphologies and interface structures were investigated by a combination of x-ray diffraction, scanning electron microscopy and high-resolution transmission electron microscopy. The sample grown at 400 °C was amorphous due to the low driving forces for nucleation and diffusion. For the samples made at 500 °C, 550 °C and 600 °C, the monoclinic BiVO4 matrix epitaxially grew on YSZ, forming the matrix, where the WO3 nanopillars were embedded in with a specific orientation relationship among BiVO4, WO3 and YSZ. However, in thin films deposited at 650 °C and 700 °C, the WO3 grains randomly grew on the YSZ substrate, which dominated the microstructures of the resultant thin films. Quantitative analyses of the microstructures revealed that the lateral grain sizes of BiVO4 and WO3 increased and the volume fraction of BiVO4 in the thin films decreased with the increase of the deposition temperature. A three-regime growth mechanism of the WO3-BiVO4 composite thin film was proposed based on the growth dynamics determined by the competition between BiVO4 and WO3.

  11. Effects of quercetin supplementation on endurance performance and maximal oxygen consumption: a meta-analysis.

    PubMed

    Pelletier, Denis M; Lacerte, Guillaume; Goulet, Eric D B

    2013-02-01

    Lately, the effect of quercetin supplementation (QS) on endurance performance (EP) and maximal oxygen consumption (VO2max) has been receiving much scientific and media attention. Therefore, a meta-analysis was performed to determine QS's ergogenic value on these variables. Studies were located with database searches (PubMed and SPORTDiscus) and cross-referencing. Outcomes represent mean percentage changes in EP (measured via power output) and VO2max between QS and placebo. Random-effects model meta-regression, mixed-effects model analog to the ANOVA, random-effects weighted mean effect summary, and magnitude-based inferences analyses were used to delineate the effects of QS. Seven research articles (representing 288 subjects) were included, producing 4 VO2max and 10 EP effect estimates. Mean QS daily intake and duration were, respectively, 960 ± 127 mg and 26 ± 24 d for the EP outcome and 1,000 ± 0 mg and 8 ± 23 d for the VO2max outcome. EP was assessed during exercise with a mean duration of 79 ± 82 min. Overall, QS improved EP by 0.74% (95% CI: 0.10-1.39, p = .02) compared with placebo. However, only in untrained individuals (0.83% ± 0.78%, p = .02) did QS significantly improve EP (trained individuals: 0.09% ± 2.15%, p = .92). There was no relationship between QS duration and EP (p = .69). Overall, QS increased VO2max by 1.94% (95% CI: 0.30-3.59, p = .02). Magnitude-based inferences suggest that the effect of QS on EP and VO2max is likely to be trivial for both trained and untrained individuals. In conclusion, this meta-analysis indicates that QS is unlikely to prove ergogenic for aerobic-oriented exercises in trained and untrained individuals.

  12. Metamaterials based on the phase transition of VO2

    NASA Astrophysics Data System (ADS)

    Liu, Hongwei; Lu, Junpeng; Renshaw Wang, Xiao

    2018-01-01

    In this article, we present a comprehensive review on recent research progress in design and fabrication of active tunable metamaterials and devices based on phase transition of VO2. Firstly, we introduce mechanisms of the metal-to-insulator phase transition (MIPT) in VO2 investigated by ultrafast THz spectroscopies. By analyzing the THz spectra, the evolutions of MIPT in VO2 induced by different external excitations are described. The superiorities of using VO2 as building blocks to construct highly tunable metamaterials are discussed. Subsequently, the recently demonstrated metamaterial devices based on VO2 are reviewed. These metamaterials devices are summarized and described in the categories of working frequency. In each working frequency range, representative metamaterials based on VO2 with different architectures and functionalities are reviewed and the contributions of the MIPT of VO2 are emphasized. Finally, we conclude the recent reports and provide a prospect on the strategies of developing future tunable metamaterials based on VO2.

  13. Heart failure and anemia: Effects on prognostic variables.

    PubMed

    Cattadori, Gaia; Agostoni, Piergiuseppe; Corrà, Ugo; Sinagra, Gianfranco; Veglia, Fabrizio; Salvioni, Elisabetta; Bonomi, Alice; La Gioia, Rocco; Scardovi, Angela B; Ferraironi, Alessandro; Emdin, Michele; Metra, Marco; Di Lenarda, Andrea; Limongelli, Giuseppe; Raimondo, Rosa; Re, Federica; Guazzi, Marco; Belardinelli, Romualdo; Parati, Gianfranco; Caravita, Sergio; Magrì, Damiano; Lombardi, Carlo; Frigerio, Maria; Oliva, Fabrizio; Girola, Davide; Mezzani, Alessandro; Farina, Stefania; Mapelli, Massimo; Scrutinio, Domenico; Pacileo, Giuseppe; Apostolo, Anna; Iorio, AnnaMaria; Paolillo, Stefania; Filardi, Pasquale Perrone; Gargiulo, Paola; Bussotti, Maurizio; Marchese, Giovanni; Correale, Michele; Badagliacca, Roberto; Sciomer, Susanna; Palermo, Pietro; Contini, Mauro; Giannuzzi, Pantaleo; Battaia, Elisa; Cicoira, Mariantonietta; Clemenza, Francesco; Minà, Chiara; Binno, Simone; Passino, Claudio; Piepoli, Massimo F

    2017-01-01

    Anemia is frequent in heart failure (HF), and it is associated with higher mortality. The predictive power of established HF prognostic parameters in anemic HF patients is unknown. Clinical, laboratory, echocardiographic and cardiopulmonary-exercise-test (CPET) data were analyzed in 3913 HF patients grouped according to hemoglobin (Hb) values. 248 (6%), 857 (22%), 2160 (55%) and 648 (17%) patients had very low (<11g/dL), low (11-12 for females, 11-13 for males), normal (12-15 for females, 13-15 for males) and high (>15) Hb, respectively. Median follow-up was 1363days (606-1883). CPETs were always performed safely. Hb was related to prognosis (Hazard ratio (HR)=0.864). No prognostic difference was observed between normal and high Hb groups. Peak oxygen consumption (VO 2 ), ventilatory efficiency (VE/VCO 2 slope), plasma sodium concentration, ejection fraction (LVEF), kidney function and Hb were independently related to prognosis in the entire population. Considering Hb groups separately, peakVO 2 (very low Hb HR=0.549, low Hb HR=0.613, normal Hb HR=0.618, high Hb HR=0.542) and LVEF (very low Hb HR=0.49, low Hb HR=0.692, normal Hb HR=0.697, high Hb HR=0.694) maintained their prognostic roles. High VE/VCO 2 slope was associated with poor prognosis only in patients with low and normal Hb. Anemic HF patients have a worse prognosis, but CPET can be safely performed. PeakVO 2 and LVEF, but not VE/VCO 2 slope, maintain their prognostic power also in HF patients with Hb<11g/dL, suggesting CPET use and a multiparametric approach in HF patients with low Hb. However, the prognostic effect of an anemia-oriented follow-up is unknown. Copyright © 2016 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  14. Facile and Low-Temperature Fabrication of Thermochromic Cr2O3/VO2 Smart Coatings: Enhanced Solar Modulation Ability, High Luminous Transmittance and UV-Shielding Function.

    PubMed

    Chang, Tianci; Cao, Xun; Li, Ning; Long, Shiwei; Gao, Xiang; Dedon, Liv R; Sun, Guangyao; Luo, Hongjie; Jin, Ping

    2017-08-09

    In the pursuit of energy efficient materials, vanadium dioxide (VO 2 ) based smart coatings have gained much attention in recent years. For smart window applications, VO 2 thin films should be fabricated at low temperature to reduce the cost in commercial fabrication and solve compatibility problems. Meanwhile, thermochromic performance with high luminous transmittance and solar modulation ability, as well as effective UV shielding function has become the most important developing strategy for ideal smart windows. In this work, facile Cr 2 O 3 /VO 2 bilayer coatings on quartz glasses were designed and fabricated by magnetron sputtering at low temperatures ranging from 250 to 350 °C as compared with typical high growth temperatures (>450 °C). The bottom Cr 2 O 3 layer not only provides a structural template for the growth of VO 2 (R), but also serves as an antireflection layer for improving the luminous transmittance. It was found that the deposition of Cr 2 O 3 layer resulted in a dramatic enhancement of the solar modulation ability (56.4%) and improvement of luminous transmittance (26.4%) when compared to single-layer VO 2 coating. According to optical measurements, the Cr 2 O 3 /VO 2 bilayer structure exhibits excellent optical performances with an enhanced solar modulation ability (ΔT sol = 12.2%) and a high luminous transmittance (T lum,lt = 46.0%), which makes a good balance between ΔT sol and T lum for smart windows applications. As for UV-shielding properties, more than 95.8% UV radiation (250-400 nm) can be blocked out by the Cr 2 O 3 /VO 2 structure. In addition, the visualized energy-efficient effect was modeled by heating a beaker of water using infrared imaging method with/without a Cr 2 O 3 /VO 2 coating glass.

  15. Hydrothermal Synthesis of VO2 Polymorphs: Advantages, Challenges and Prospects for the Application of Energy Efficient Smart Windows.

    PubMed

    Li, Ming; Magdassi, Shlomo; Gao, Yanfeng; Long, Yi

    2017-09-01

    Vanadium dioxide (VO 2 ) is a widely studied inorganic phase change material, which has a reversible phase transition from semiconducting monoclinic to metallic rutile phase at a critical temperature of τ c ≈ 68 °C. The abrupt decrease of infrared transmittance in the metallic phase makes VO 2 a potential candidate for thermochromic energy efficient windows to cut down building energy consumption. However, there are three long-standing issues that hindered its application in energy efficient windows: high τ c , low luminous transmittance (T lum ), and undesirable solar modulation ability (ΔT sol ). Many approaches, including nano-thermochromism, porous films, biomimetic surface reconstruction, gridded structures, antireflective overcoatings, etc, have been proposed to tackle these issues. The first approach-nano-thermochromism-which is to integrate VO 2 nanoparticles in a transparent matrix, outperforms the rest; while the thermochromic performance is determined by particle size, stoichiometry, and crystallinity. A hydrothermal method is the most common method to fabricate high-quality VO 2 nanoparticles, and has its own advantages of large-scale synthesis and precise phase control of VO 2 . This Review focuses on hydrothermal synthesis, physical properties of VO 2 polymorphs, and their transformation to thermochromic VO 2 (M), and discusses the advantages, challenges, and prospects of VO 2 (M) in energy-efficient smart windows application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Enhancement Strategies for Frame-To Uas Stereo Visual Odometry

    NASA Astrophysics Data System (ADS)

    Kersten, J.; Rodehorst, V.

    2016-06-01

    Autonomous navigation of indoor unmanned aircraft systems (UAS) requires accurate pose estimations usually obtained from indirect measurements. Navigation based on inertial measurement units (IMU) is known to be affected by high drift rates. The incorporation of cameras provides complementary information due to the different underlying measurement principle. The scale ambiguity problem for monocular cameras is avoided when a light-weight stereo camera setup is used. However, also frame-to-frame stereo visual odometry (VO) approaches are known to accumulate pose estimation errors over time. Several valuable real-time capable techniques for outlier detection and drift reduction in frame-to-frame VO, for example robust relative orientation estimation using random sample consensus (RANSAC) and bundle adjustment, are available. This study addresses the problem of choosing appropriate VO components. We propose a frame-to-frame stereo VO method based on carefully selected components and parameters. This method is evaluated regarding the impact and value of different outlier detection and drift-reduction strategies, for example keyframe selection and sparse bundle adjustment (SBA), using reference benchmark data as well as own real stereo data. The experimental results demonstrate that our VO method is able to estimate quite accurate trajectories. Feature bucketing and keyframe selection are simple but effective strategies which further improve the VO results. Furthermore, introducing the stereo baseline constraint in pose graph optimization (PGO) leads to significant improvements.

  17. Efficient solar-driven water splitting by nanocone BiVO4-perovskite tandem cells

    PubMed Central

    Qiu, Yongcai; Liu, Wei; Chen, Wei; Chen, Wei; Zhou, Guangmin; Hsu, Po-Chun; Zhang, Rufan; Liang, Zheng; Fan, Shoushan; Zhang, Yuegang; Cui, Yi

    2016-01-01

    Bismuth vanadate (BiVO4) has been widely regarded as a promising photoanode material for photoelectrochemical (PEC) water splitting because of its low cost, its high stability against photocorrosion, and its relatively narrow band gap of 2.4 eV. However, the achieved performance of the BiVO4 photoanode remains unsatisfactory to date because its short carrier diffusion length restricts the total thickness of the BiVO4 film required for sufficient light absorption. We addressed the issue by deposition of nanoporous Mo-doped BiVO4 (Mo:BiVO4) on an engineered cone-shaped nanostructure, in which the Mo:BiVO4 layer with a larger effective thickness maintains highly efficient charge separation and high light absorption capability, which can be further enhanced by multiple light scattering in the nanocone structure. As a result, the nanocone/Mo:BiVO4/Fe(Ni)OOH photoanode exhibits a high water-splitting photocurrent of 5.82 ± 0.36 mA cm−2 at 1.23 V versus the reversible hydrogen electrode under 1-sun illumination. We also demonstrate that the PEC cell in tandem with a single perovskite solar cell exhibits unassisted water splitting with a solar-to-hydrogen conversion efficiency of up to 6.2%. PMID:27386565

  18. A simple and low-cost combustion method to prepare monoclinic VO2 with superior thermochromic properties

    PubMed Central

    Cao, Ziyi; Xiao, Xiudi; Lu, Xuanming; Zhan, Yongjun; Cheng, Haoliang; Xu, Gang

    2016-01-01

    In this approach, the VO2 nanoparticles have been successfully fabricated via combusting the low-cost precursor solution consisted of NH4VO3, C2H6O2 and C2H5OH. By the XRD, TEM and XPS analysis, it can be found that the synthetic monoclinic VO2 is single crystal and no impurity is defined. After dispersing the VO2 nanoparticles into the polymer, the solar modulation of VO2-based composite film is up to 12.5% with luminous transmission and haze around 62.2% and 0.5%, respectively. In other words, the composite films show high performance of thermochromic properties. This could open an efficient way to fabricate low-cost and large-scale VO2 (M) nanoparticles and thermochromic films. PMID:27976748

  19. BiVO{sub 4} photoanodes for water splitting with high injection efficiency, deposited by reactive magnetron co-sputtering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Haibo; Institute for Solar Fuels, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin; Freudenberg, Norman

    2016-04-15

    Photoactive bismuth vanadate (BiVO{sub 4}) thin films were deposited by reactive co-magnetron sputtering from metallic Bi and V targets. The effects of the V-to-Bi ratio, molybdenum doping and post-annealing on the crystallographic and photoelectrochemical (PEC) properties of the BiVO{sub 4} films were investigated. Phase-pure monoclinic BiVO{sub 4} films, which are more photoactive than the tetragonal BiVO{sub 4} phase, were obtained under slightly vanadium-rich conditions. After annealing of the Mo-doped BiVO{sub 4} films, the photocurrent increased 2.6 times compared to undoped films. After optimization of the BiVO{sub 4} film thickness, the photocurrent densities (without a catalyst or a blocking layer ormore » a hole scavenger) exceeded 1.2 mA/cm{sup 2} at a potential of 1.23 V{sub RHE} under solar AM1.5 irradiation. The surprisingly high injection efficiency of holes into the electrolyte is attributed to the highly porous film morphology. This co-magnetron sputtering preparation route for photoactive BiVO{sub 4} films opens new possibilities for the fabrication of large-scale devices for water splitting.« less

  20. Enhanced Visible Transmittance of Thermochromic VO2 Thin Films by SiO2 Passivation Layer and Their Optical Characterization

    PubMed Central

    Yu, Jung-Hoon; Nam, Sang-Hun; Lee, Ji Won; Boo, Jin-Hyo

    2016-01-01

    This paper presents the preparation of high-quality vanadium dioxide (VO2) thermochromic thin films with enhanced visible transmittance (Tvis) via radio frequency (RF) sputtering and plasma enhanced chemical vapor deposition (PECVD). VO2 thin films with high Tvis and excellent optical switching efficiency (Eos) were successfully prepared by employing SiO2 as a passivation layer. After SiO2 deposition, the roughness of the films was decreased 2-fold and a denser structure was formed. These morphological changes corresponded to the results of optical characterization including the haze, reflectance and absorption spectra. In spite of SiO2 coating, the phase transition temperature (Tc) of the prepared films was not affected. Compared with pristine VO2, the total layer thickness after SiO2 coating was 160 nm, which is an increase of 80 nm. Despite the thickness change, the VO2 thin films showed a higher Tvis value (λ 650 nm, 58%) compared with the pristine samples (λ 650 nm, 43%). This enhancement of Tvis while maintaining high Eos is meaningful for VO2-based smart window applications. PMID:28773679

  1. Structural analysis of LaVO3 thin films under epitaxial strain

    NASA Astrophysics Data System (ADS)

    Meley, H.; Karandeep, Oberson, L.; de Bruijckere, J.; Alexander, D. T. L.; Triscone, J.-M.; Ghosez, Ph.; Gariglio, S.

    2018-04-01

    Rare earth vanadate perovskites exhibit a phase diagram in which two different types of structural distortions coexist: the strongest, the rotation of the oxygen octahedra, comes from the small tolerance factor of the perovskite cell (t = 0.88 for LaVO3) and the smaller one comes from inter-site d-orbital interactions manifesting as a cooperative Jahn-Teller effect. Epitaxial strain acts on octahedral rotations and crystal field symmetry to alter this complex lattice-orbit coupling. In this study, LaVO3 thin film structures have been investigated by X-ray diffraction and scanning transmission electron microscopy. The analysis shows two different orientations of octahedral tilt patterns, as well as two distinct temperature behaviors, for compressive and tensile film strain states. Ab initio calculations capture the strain effect on the tilt pattern orientation in agreement with experimental data.

  2. Epitaxial VO2 thin-film-based radio-frequency switches with electrical activation

    NASA Astrophysics Data System (ADS)

    Lee, Jaeseong; Lee, Daesu; Cho, Sang June; Seo, Jung-Hun; Liu, Dong; Eom, Chang-Beom; Ma, Zhenqiang

    2017-09-01

    Vanadium dioxide (VO2) is a correlated material exhibiting a sharp insulator-to-metal phase transition (IMT) caused by temperature change and/or bias voltage. We report on the demonstration of electrically triggered radio-frequency (RF) switches based on epitaxial VO2 thin films. The highly epitaxial VO2 and SnO2 template layer was grown on a (001) TiO2 substrate by pulsed laser deposition (PLD). A resistance change of the VO2 thin films of four orders of magnitude was achieved with a relatively low threshold voltage, as low as 13 V, for an IMT phase transition. VO2 RF switches also showed high-frequency responses of insertion losses of -3 dB at the on-state and return losses of -4.3 dB at the off-state over 27 GHz. Furthermore, an intrinsic cutoff frequency of 17.4 THz was estimated for the RF switches. The study on electrical IMT dynamics revealed a phase transition time of 840 ns.

  3. Electrical Switching in Semiconductor-Metal Self-Assembled VO2 Disordered Metamaterial Coatings

    PubMed Central

    Kumar, Sunil; Maury, Francis; Bahlawane, Naoufal

    2016-01-01

    As a strongly correlated metal oxide, VO2 inspires several highly technological applications. The challenging reliable wafer-scale synthesis of high quality polycrystalline VO2 coatings is demonstrated on 4” Si taking advantage of the oxidative sintering of chemically vapor deposited VO2 films. This approach results in films with a semiconductor-metal transition (SMT) quality approaching that of the epitaxial counterpart. SMT occurs with an abrupt electrical resistivity change exceeding three orders of magnitude with a narrow hysteresis width. Spatially resolved infrared and Raman analyses evidence the self-assembly of VO2 disordered metamaterial, compresing monoclinic (M1 and M2) and rutile (R) domains, at the transition temperature region. The M2 mediation of the M1-R transition is spatially confined and related to the localized strain-stabilization of the M2 phase. The presence of the M2 phase is supposed to play a role as a minor semiconducting phase far above the SMT temperature. In terms of application, we show that the VO2 disordered self-assembly of M and R phases is highly stable and can be thermally triggered with high precision using short heating or cooling pulses with adjusted strengths. Such a control enables an accurate and tunable thermal control of the electrical switching. PMID:27883052

  4. Nitrate-containing beetroot juice reduces oxygen consumption during submaximal exercise in low but not high aerobically fit male runners

    PubMed Central

    Carriker, Colin R.; Vaughan, Roger A.; VanDusseldorp, Trisha A.; Johnson, Kelly E.; Beltz, Nicholas M.; McCormick, James J.; Cole, Nathan H.; Gibson, Ann L.

    2016-01-01

    [Purpose] To examine the effect of a 4-day NO3- loading protocol on the submaximal oxygen cost of both low fit and high fit participants at five different exercise intensities. [Methods] Eleven (6 high fit, VO2max 60.1 ± 4.6ml/kg/min; 5 low fit, VO2max 42.4 ± 3.2ml/ kg/min) participants were initially assigned to a placebo (PL; negligible NO3-) or inorganic nitrate-rich (NR; 6.2 mmol nitrate/day) group using a double-blind, placebo-controlled, crossover design. Participants completed three trials (T1, T2 and T3). T1 included a maximal aerobic capacity (VO2max) treadmill test. A 6-day washout, minimizing nitrate consumption, preceded T2. Each of the four days prior to T2 and T3, participants consumed either PL or NR with the final dose 2.5 hours prior to exercise. A 14-day washout followed T2. T2 and T3 consisted of 5-minute submaximal treadmill bouts (45, 60, 70, 80 and 85% VO2max) determined during T1. [Results] Low fit nitrate-supplemented participants consumed less oxygen (p<0.05) at lower workloads (45% and 60% VO2max) compared to placebo trials; changes were not observed in high fit participants. The two lowest intensity workloads of 45 and 60% VO2max revealed the greatest correlation (r=0.54, p=0.09 and r=0.79, p<0.05; respectively) between VO2max and change in oxygen consumption. No differences were found between conditions for heart rate, respiratory exchange ratio or rating of perceived exertion for either fitness group. [Conclusion] Nitrate consumption promotes reduced oxygen consumption at lower exercise intensities in low fit, but not high fit males. Lesser fit individuals may receive greater benefit than higher fit participants exercising at intensities <60% VO2max. PMID:28150476

  5. Thermal hysteresis measurement of the VO2 emissivity and its application in thermal rectification.

    PubMed

    Gomez-Heredia, C L; Ramirez-Rincon, J A; Ordonez-Miranda, J; Ares, O; Alvarado-Gil, J J; Champeaux, C; Dumas-Bouchiat, F; Ezzahri, Y; Joulain, K

    2018-05-31

    Hysteresis loops in the emissivity of VO 2 thin films grown on sapphire and silicon substrates by a pulsed laser deposition process are experimentally measured through the thermal-wave resonant cavity technique. Remarkable variations of about 43% are observed in the emissivity of both VO 2 films, within their insulator-to-metal and metal-to-insulator transitions. It is shown that: i) The principal hysteresis width (maximum slope) in the VO 2 emissivity of the VO 2  + silicon sample is around 3 times higher (lower) than the corresponding one of the VO 2  + sapphire sample. VO 2 synthesized on silicon thus exhibits a wider principal hysteresis loop with slower MIT than VO 2 on sapphire, as a result of the significant differences on the VO 2 film microstructures induced by the silicon or sapphire substrates. ii) The hysteresis width along with the rate of change of the VO 2 emissivity in a VO 2  + substrate sample can be tuned with its secondary hysteresis loop. iii) VO 2 samples can be used to build a radiative thermal diode able to operate with a rectification factor as high as 87%, when the temperature difference of its two terminals is around 17 °C. This record-breaking rectification constitutes the highest one reported in literature, for a relatively small temperature change of diode terminals.

  6. Sputtering Deposition of Sandwich-Structured V2O5/Metal (V, W)/V2O5 Multilayers for the Preparation of High-Performance Thermally Sensitive VO2 Thin Films with Selectivity of VO2 (B) and VO2 (M) Polymorph.

    PubMed

    Liu, Hengwu; Wan, Dongyun; Ishaq, Ahmad; Chen, Lanli; Guo, Beibei; Shi, Siqi; Luo, Hongjie; Gao, Yanfeng

    2016-03-01

    For specific application to an uncooled infrared detector, VO2 thin films should have a series of characteristics including purposefully chosen polymorphs, accurate stoichiometry, phase stabilization, a high temperature-coefficient of resistance (TCR), and suitable square-resistance. This work reports controllable preparation of high-performance VO2 films via post annealing of a sandwich-structured V2O5/metal (V, W)/V2O5 multilayer precursor, which was deposited by RF magnetron sputtering. This sandwich structure can dynamically regulate oxygen contents and doping element levels in the films, enabling us to achieve accurate regulation of stoichiometry and polymorphs. The precursor films undergo a B to M phase transition depending on the quantity of the metal layers. At the thickness of the metal layer below a limitation, the resulting film after heat treatment was VO2 (B), and above the limitation, the product was VO2 (M). The optical modulation of the VO2 (M) in the near-infrared region can be tuned from 1.2 to 39.8% (ΔT2000 nm). TCR values can range from -1.89 to -4.29%/K and the square-resistances at room temperature (R0) from 69.68 to 12.63 kΩ. The simplicity in phase regulation of the present method and the superior optical and electrical properties of the films may allow its wide applications in thermo-opto-electro sensing devices.

  7. A comparison of the shuttle and 6 minute walking tests with measured peak oxygen consumption in patients with heart failure.

    PubMed

    Green, D J; Watts, K; Rankin, S; Wong, P; O'Driscoll, J G

    2001-09-01

    This study investigated the use of an incremental, externally-paced 10 m shuttle walk test (SWT) as an objective, reliable and predictive test of functional capacity in patients with heart failure (CHF). The SWT was compared to a 6 minute walk test (6WT) and a maximal symptom-limited treadmill peak oxygen consumption (VO2peak) test. Experiment 1 examined the reproducibility of the SWT. Two SWF trials were performed and distance ambulated (DA), heart rate (HR) and rate of perceived exertion (RPE) results compared. In experiment 2, SWT, 6WT, and VO2 peak tests were performed and HR. RPE and ambulatory VO2 compared. The SWT demonstrated strong test/retest reliability for DA (r = 0.98). HR (r = 0.96) and RPE (r = 0.89). Treadmill VO2 peak was significantly correlated with DA during the SWT (r = 0.83, P < 0.05), but not the 6WT. SWT peak VO2 (18.5 +/- 1.8 ml.kg(-1) x min(-1)) and treadmill VO2 peak (18.3 +/-2.0 ml.kg(-1) x min(-1)) were also highly correlated (r = 0.78, P < 0.05). Conversely, 6WT peak VO2 and treadmill VO2 peak were not significantly correlated. This study suggests the SWT is a reliable, objective test, highly predictive of VO2 peak which may be a more optimal field exercise test than the self paced 6WT.

  8. Improving the electrocatalytic performance of carbon nanotubes for VO2+/VO2+ redox reaction by KOH activation

    NASA Astrophysics Data System (ADS)

    Dai, Lei; Jiang, Yingqiao; Meng, Wei; Zhou, Huizhu; Wang, Ling; He, Zhangxing

    2017-04-01

    In this paper, carbon nanotubes (CNTs) was activated by KOH treatment at high temperature and investigated as catalyst for VO2+/VO2+ redox reaction for vanadium redox flow battery (VRFB). X-ray photoelectron spectroscopy results suggest that the oxygen-containing groups can be introduced on CNTs by KOH activation. The mass transfer of vanadium ions can be accelerated by chemical etching by KOH activation and improved wettability due to the introduction of hydrophilic groups. The electrochemical properties of VO2+/VO2+ redox reaction can be enhanced by introduced oxygen-containing groups as active sites. The sample treated at 900 °C with KOH/CNTs mass ratio of 3:1 (CNTs-3) exhibits the highest electrocatalytic activity for VO2+/VO2+ redox reaction. The cell using CNTs-3 as positive catalyst demonstrates the smallest electrochemical polarization, the highest capacity and efficiency among the samples. Using KOH-activated CNTs-3 can increase the average energy efficiency of the cell by 4.4%. This work suggests that KOH-activated CNTs is a low-cost, efficient and promising catalyst for VO2+/VO2+ redox reaction for VRFB system.

  9. The annealing mechanism of the radiation-induced vacancy-oxygen defect in silicon

    NASA Astrophysics Data System (ADS)

    Voronkov, V. V.; Falster, R.; Londos, C. A.

    2012-06-01

    Annealing experiments on the VO defect (the A-centre) produced by radiation in silicon—reported long ago—have been re-examined in order to deduce the two most important properties of VO: its diffusivity and the equilibrium constant for VO dissociation into V + O. The loss rate of VO is accounted for by two major reactions. One is the conventional reaction of the trapping of mobile VO by oxygen, thus producing VO2. The other is an annihilation of vacancies, which coexist in an equilibrium ratio with VO, by radiation-produced interstitial point defects. In some cases, a minor reaction, VO + V, should also be taken into account. The emerging minor defects V2O are also highly mobile. They partially dissociate back and partially get trapped by oxygen producing stable V2O2 defects.

  10. n-VO2/p-GaN based nitride-oxide heterostructure with various thickness of VO2 layer grown by MBE

    NASA Astrophysics Data System (ADS)

    Wang, Minhuan; Bian, Jiming; Sun, Hongjun; Liu, Weifeng; Zhang, Yuzhi; Luo, Yingmin

    2016-12-01

    High quality VO2 films with precisely controlled thickness were grown on p-GaN/sapphire substrates by oxide molecular beam epitaxy (O-MBE). Results indicated that a distinct reversible semiconductor-to-metal (SMT) phase transition was observed for all the samples in the temperature dependent electrical resistance measurement, and the influence of VO2 layer thickness on the SMT properties of the as-grown n-VO2/p-GaN based nitride-oxide heterostructure was investigated. Meanwhile, the clear rectifying transport characteristics originated from the n-VO2/p-GaN interface were demonstrated before and after SMT of the VO2 over layer, which were attributed to the p-n junction behavior and Schottky contact character, respectively. Moreover, the X-ray photoelectron spectroscopy (XPS) analyses confirmed the valence state of vanadium (V) in VO2 films was principally composed of V4+ with trace amount of V5+. The design and modulation of the n-VO2/p-GaN based heterostructure devices will benefit significantly from these achievements.

  11. High degree gravitational sensitivity from Mars orbiters for the GMM-1 gravity model

    NASA Technical Reports Server (NTRS)

    Lerch, F. J.; Smith, D. E.; Chan, J. C.; Patel, G. B.; Chinn, D. S.

    1994-01-01

    Orbital sensitivity of the gravity field for high degree terms (greater than 30) is analyzed on satellites employed in a Goddard Mars Model GMM-1, complete in spherical harmonics through degree and order 50. The model is obtained from S-band Doppler data on Mariner 9 (M9), Viking Orbiter 1 (VO1), and Viking Orbiter 2 (VO2) spacecraft, which were tracked by the NASA Deep Space Network on seven different highly eccentric orbits. The main sensitivity of the high degree terms is obtained from the VO1 and VO2 low orbits (300 km periapsis altitude), where significant spectral sensitivity is seen for all degrees out through degree 50. The velocity perturbations show a dominant effect at periapsis and significant effects out beyond the semi-latus rectum covering over 180 degrees of the orbital groundtrack for the low altitude orbits. Because of the wideband of periapsis motion covering nearly 180 degrees in w and +39 degrees in latitude coverage, the VO1 300 km periapsis altitude orbit with inclination of 39 degrees gave the dominant sensitivity in the GMM-1 solution for the high degree terms. Although the VO2 low periapsis orbit has a smaller band of periapsis mapping coverage, it strongly complements the VO1 orbit sensitivity for the GMM-1 solution with Doppler tracking coverage over a different inclination of 80 degrees.

  12. (LaTiO3)n/(LaVO3)n as a model system for unconventional charge transfer and polar metallicity

    NASA Astrophysics Data System (ADS)

    Weng, Yakui; Zhang, Jun-Jie; Gao, Bin; Dong, Shuai

    2017-04-01

    At interfaces between oxide materials, lattice and electronic reconstructions always play important roles in exotic phenomena. In this study, the density functional theory and maximally localized Wannier functions are employed to investigate the (LaTiO3)n/(LaVO3)n magnetic superlattices. The electron transfer from Ti3 + to V3 + is predicted, which violates the intuitive band alignment based on the electronic structures of LaTiO3 and LaVO3. Such unconventional charge transfer quenches the magnetism of LaTiO3 layer mostly and leads to metal-insulator transition in the n =1 superlattice when the stacking orientation is altered. In addition, the compatibility among the polar structure, ferrimagnetism, and metallicity is predicted in the n =2 superlattice.

  13. A cost-effective process to prepare VO{sub 2} (M) powder and films with superior thermochromic properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Xiudi; Zhang, Hua; Chai, Guanqi

    2014-03-01

    Graphical abstract: Combining codeposition and short time post annealing, VO{sub 2} (M) with high quality and excellent phase transition performance is obtained. After mixing the VO{sub 2} powder with acrylic resin, the composite films deposited on glass show superior visible transmission and solar modulation, which can be used as an excellent candidate of low cost smart window in energy saving field. - Highlights: • The VO{sub 2} powder obtained by short time thermolysis method is high purity and crystallinity with superior phase transition performance. • The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w =more » 0.4 at%. • After mixing VO{sub 2} powder with acrylic resin, the maximal visible transmission of the composite films is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. • Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO{sub 2} still show superior transmission modulation about 26.4%, which means that it is a potential candidate as smart windows. - Abstract: VO{sub 2} powder with superior phase transition performance was prepared by convenient thermolysis method. The results illustrated that VO{sub 2} powder show high purity and crystallinity. VO{sub 2} particles are transformed from cluster to quasi-sphere with the increase of annealing temperature. The DSC analysis proves that VO{sub 2} show superior phase transition performance around 68 °C. The phase transition temperature can be reduced to 33.5 °C by 1.8 at% tungsten doping. The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w = 0.4 at%. After mixing VO{sub 2} powder with acrylic resin, the maximal visible transmission of the composite thin films on glass is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO{sub 2} still show superior transmission modulation about 26.4% at 2000 nm, which means that it is a potential candidate as smart windows.« less

  14. Persistent electrochemical performance in epitaxial VO 2(B)

    DOE PAGES

    Lee, Shinbuhm; Sun, Xiao -Guang; Lubimtsev, Andrew A.; ...

    2017-03-07

    Discovering high-performance energy storage materials is indispensable for renewable energy, electric vehicle performance, and mobile computing. Owing to the open atomic framework and good room temperature conductivity, bronze-phase vanadium dioxide [VO 2(B)] has been regarded as a highly promising electrode material for Li ion batteries. However, previous attempts were unsuccessful to show the desired cycling performance and capacity without chemical modification. Here, we show with epitaxial VO 2(B) films that one can accomplish the theoretical limit for capacity with persistent charging–discharging cyclability owing to the high structural stability and unique open pathways for Li ion conduction. Atomic-scale characterization by scanningmore » transmission electron microscopy and density functional theory calculations also reveal that the unique open pathways in VO 2(B) provide the most stable sites for Li adsorption and diffusion. Furthermore, this work ultimately demonstrates that VO 2(B) is a highly promising energy storage material and has no intrinsic hindrance in achieving superior cyclability with a very high power and capacity in a Li-ion conductor.« less

  15. High-intensity interval running is perceived to be more enjoyable than moderate-intensity continuous exercise: implications for exercise adherence.

    PubMed

    Bartlett, Jonathan D; Close, Graeme L; MacLaren, Don P M; Gregson, Warren; Drust, Barry; Morton, James P

    2011-03-01

    The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6 × 3 min at 90% VO(2max) interspersed with 6 × 3 min active recovery at 50% VO(2max) with a 7-min warm-up and cool down at 70% VO(2max)) or 50 min moderate-intensity continuous running at 70% VO(2max). Ratings of perceived enjoyment after exercise were higher (P < 0.05) following interval running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P < 0.05) ratings of perceived exertion (14 ± 1 vs. 13 ± 1). There was no difference (P < 0.05) in average heart rate (88 ± 3 vs. 87 ± 3% maximum heart rate), average VO(2) (71 ± 6 vs. 73 ± 4%VO(2max)), total VO(2) (162 ± 16 vs. 166 ± 27 L) or energy expenditure (811 ± 83 vs. 832 ± 136 kcal) between protocols. The greater enjoyment associated with high-intensity interval running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.

  16. Time limit and VO2 slow component at intensities corresponding to VO2max in swimmers.

    PubMed

    Fernandes, R J; Cardoso, C S; Soares, S M; Ascensão, A; Colaço, P J; Vilas-Boas, J P

    2003-11-01

    The purpose of this study was to measure, in swimming pool conditions and with high level swimmers, the time to exhaustion at the minimum velocity that elicits maximal oxygen consumption (TLim at vVO(2)max), and the corresponding VO(2) slow component (O(2)SC). The vVO(2)max was determined through an intermittent incremental test (n = 15). Forty-eight hours later, TLim was assessed using an all-out swim at vVO(2)max until exhaustion. VO(2) was measured through direct oximetry and the swimming velocity was controlled using a visual light-pacer. Blood lactate concentrations and heart rate values were also measured. Mean VO(2)max for the incremental test was 5.09 +/- 0.53 l/min and the corresponding vVO(2)max was 1.46 +/- 0.06 m/s. Mean TLim value was 260.20 +/- 60.73 s and it was inversely correlated with the velocity of anaerobic threshold (r = -0.54, p < 0.05). This fact, associated with the inverse relationship between TLim and vVO(2)max (r = -0.47, but only for p < 0.10), suggested that swimmers' lower level aerobic metabolic rate might be associated with a larger capacity to sustain that exercise intensity. O(2)SC reached 274.11 +/- 152.83 l/min and was correlated with TLim (r = 0.54), increased ventilation in TLim test (r = 0.52) and energy cost of the respiratory muscles (r = 0.51), for p < 0.05. These data suggest that O(2)SC was also observed in the swimming pool, in high level swimmers performing at vVO(2)max, and that higher TLim seems to correspond to higher expected O(2)SC amplitude. These findings seem to bring new data with application in middle distance swimming.

  17. The influence of exercise duration at VO2 max on the off-transient pulmonary oxygen uptake phase during high intensity running activity.

    PubMed

    Billat, V L; Hamard, L; Koralsztein, J P

    2002-12-01

    The purpose of this study was to examine the influence of time run at maximal oxygen uptake (VO2 max) on the off-transient pulmonary oxygen uptake phase after supra-lactate threshold runs. We hypothesised: 1) that among the velocities eliciting VO2 max there is a velocity threshold from which there is a slow component in the VO2-off transient, and 2) that at this velocity the longer the duration of this time at VO2 max (associated with an accumulated oxygen kinetics since VO2 can not overlap VO2 max), the longer is the off-transient phase of oxygen uptake kinetics. Nine long-distance runners performed five maximal tests on a synthetic track (400 m) while breathing through the COSMED K4b2 portable, telemetric metabolic analyser: i) an incremental test which determined VO2 max, the minimal velocity associated with VO2 max (vVO2 max) and the velocity at the lactate threshold (vLT), ii) and in a random order, four supra-lactate threshold runs performed until exhaustion at vLT + 25, 50, 75 and 100% of the difference between vLT and vVO2 max (vdelta25, vdelta50, vdelta75, vdelta100). At vdelta25, vdelta50 (= 91.0 +/- 0.9% vVO2 max) and vdelta75, an asymmetry was found between the VO2 on (double exponential) and off-transient (mono exponential) phases. Only at vdelta75 there was at positive relationship between the time run at VO2 max (%tlimtot) and the VO2 recovery time constant (Z = 1.8, P = 0.05). In conclusion, this study showed that among the velocities eliciting VO2 max, vdelta75 is the velocity at which the longer the duration of the time at VO2 max, the longer is the off-transient phase of oxygen uptake kinetics. It may be possible that at vdelta50 there is not an accumulated oxygen deficit during the plateau of VO2 at VO2 max and that the duration of the time at VO2 max during the exhaustive runs at vdelta100, could be too short to induce an accumulating oxygen deficit affecting the oxygen recovery.

  18. Physical activity enhances metabolic fitness independently of cardiorespiratory fitness in marathon runners.

    PubMed

    Laye, M J; Nielsen, M B; Hansen, L S; Knudsen, T; Pedersen, B K

    2015-01-01

    High levels of cardiovascular fitness (CRF) and physical activity (PA) are associated with decreased mortality and risk to develop metabolic diseases. The independent contributions of CRF and PA to metabolic disease risk factors are unknown. We tested the hypothesis that runners who run consistently >50 km/wk and/or >2 marathons/yr for the last 5 years have superior metabolic fitness compared to matched sedentary subjects (CRF, age, gender, and BMI). Case-control recruitment of 31 pairs of runner-sedentary subjects identified 10 matched pairs with similar VO2max (mL/min/kg) (similar-VO2max). The similar-VO2max group was compared with a group of age, gender, and BMI matched pairs who had the largest difference in VO2max (different-VO2max). Primary outcomes that defined metabolic fitness including insulin response to an oral glucose tolerance test, fasting lipids, and fasting insulin were superior in runners versus sedentary controls despite similar VO2max. Furthermore, performance (velocity at VO2max, running economy), improved exercise metabolism (lactate threshold), and skeletal muscle levels of mitochondrial proteins were superior in runners versus sedentary controls with similar VO2max. In conclusion subjects with a high amount of PA have more positive metabolic health parameters independent of CRF. PA is thus a good marker against metabolic diseases.

  19. Physical Activity Enhances Metabolic Fitness Independently of Cardiorespiratory Fitness in Marathon Runners

    PubMed Central

    Laye, M. J.; Nielsen, M. B.; Hansen, L. S.; Knudsen, T.; Pedersen, B. K.

    2015-01-01

    High levels of cardiovascular fitness (CRF) and physical activity (PA) are associated with decreased mortality and risk to develop metabolic diseases. The independent contributions of CRF and PA to metabolic disease risk factors are unknown. We tested the hypothesis that runners who run consistently >50 km/wk and/or >2 marathons/yr for the last 5 years have superior metabolic fitness compared to matched sedentary subjects (CRF, age, gender, and BMI). Case-control recruitment of 31 pairs of runner-sedentary subjects identified 10 matched pairs with similar VO2max (mL/min/kg) (similar-VO2max). The similar-VO2max group was compared with a group of age, gender, and BMI matched pairs who had the largest difference in VO2max (different-VO2max). Primary outcomes that defined metabolic fitness including insulin response to an oral glucose tolerance test, fasting lipids, and fasting insulin were superior in runners versus sedentary controls despite similar VO2max. Furthermore, performance (velocity at VO2max, running economy), improved exercise metabolism (lactate threshold), and skeletal muscle levels of mitochondrial proteins were superior in runners versus sedentary controls with similar VO2max. In conclusion subjects with a high amount of PA have more positive metabolic health parameters independent of CRF. PA is thus a good marker against metabolic diseases. PMID:25821340

  20. Preparation and investigation of sputtered vanadium dioxide films with large phase-transition hysteresis loops

    NASA Astrophysics Data System (ADS)

    Zhang, Huafu; Wu, Zhiming; He, Qiong; Jiang, Yadong

    2013-07-01

    Vanadium dioxide (VO2) films with large phase-transition hysteresis loops were fabricated on glass substrates by reactive direct current (DC) magnetron sputtering in Ar/O2 atmosphere and subsequent in situ annealing process in pure oxygen. The crystal structure, chemical composition, morphology and metal-insulator transition (MIT) properties of the deposited films were investigated. The results reveal that the films show a polycrystalline nature with a (0 1 1) preferred orientation and consist of small spheroidal nanoparticles. All the deposited VO2 films show large hysteresis loops due to the small density of nucleating defects and the large interfacial energies, which are determined by the characteristics of the particles in the films, namely the small transversal grain size and the spheroidal shape. The film comprising the smallest spheroidal nanoparticles not only shows a large hysteresis width of 36.3 °C but also shows a low transition temperature of 32.2 °C upon cooling. This experiment facilitates the civilian applications of the VO2 films on glass substrates in optical storage-type devices.

  1. Hybrid Ag 2VO 2PO 4/CF x as a High Capacity and Energy Cathode for Primary Batteries

    DOE PAGES

    Li, Yue Ru; Bruck, Andrea M.; Brady, Alexander B.; ...

    2017-08-18

    In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2VO 2PO 4/CF x) cathodes with various weight ratios. Through modification of the Ag 2VO 2PO 4/CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2VO 2PO 4. Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2VO 2PO 4 dominates the electrodemore » mass (i.e. 75/25 Ag 2VO 2PO 4/CF x) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2VO 2PO 4/CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2VO 2PO 4/CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.« less

  2. Hybrid Ag 2VO 2PO 4/CF x as a High Capacity and Energy Cathode for Primary Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yue Ru; Bruck, Andrea M.; Brady, Alexander B.

    In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2VO 2PO 4/CF x) cathodes with various weight ratios. Through modification of the Ag 2VO 2PO 4/CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2VO 2PO 4. Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2VO 2PO 4 dominates the electrodemore » mass (i.e. 75/25 Ag 2VO 2PO 4/CF x) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2VO 2PO 4/CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2VO 2PO 4/CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.« less

  3. Reference Model for Performance Management in Service-Oriented Virtual Organization Breeding Environments

    NASA Astrophysics Data System (ADS)

    Paszkiewicz, Zbigniew; Picard, Willy

    Performance management (PM) is a key function of virtual organization (VO) management. A large set of PM indicators has been proposed and evaluated within the context of virtual breeding environments (VBEs). However, it is currently difficult to describe and select suitable PM indicators because of the lack of a common vocabulary and taxonomies of PM indicators. Therefore, there is a need for a framework unifying concepts in the domain of VO PM. In this paper, a reference model for VO PM is presented in the context of service-oriented VBEs. In the proposed reference model, both a set of terms that could be used to describe key performance indicators, and a set of taxonomies reflecting various aspects of PM are proposed. The proposed reference model is a first attempt and a work in progress that should not be supposed exhaustive.

  4. Exploring the work function variability and structural stability of VO2(1 1 0) surface upon noble metal (Ag, Au, Pt) adsorption and incorporation

    NASA Astrophysics Data System (ADS)

    Chen, Lanli; Cui, Yuanyuan; Shi, Siqi; Luo, Hongjie; Gao, Yanfeng

    2018-08-01

    Vanadium dioxide (VO2) has attracted great attention, with scientific and technological advances over the past few decades due to its reversible metal-insulator transition at 340 K. However, the high phase transition temperature (Tc) of VO2 limits its practical applications. Our first-principles calculations show that VO2(1 1 0) surfaces with adsorbed noble metals (Ag, Au, Pt) exhibit a lower work function compared with the clean surface and further induces a lower Tc due to charge transfer from the noble metals to the VO2(1 1 0) surface. However, the work functions of the VO2(1 1 0) surfaces after the incorporation of noble metals are higher than that of the clean surface. In addition, the results of formation energies of various configurations show that the VO2(1 1 0) surface with the adsorption and incorporation of Ag is energetically more favorable than those with Au and Pt. Therefore, it may be concluded that the adsorption and incorporation of noble metals can not only tailor the work function of VO2, in turn realizing the rational tuning of Tc of VO2, but also stabilize the structures of VO2 thin films. These results provide guidance for further exploration of VO2-based optical switching devices and smart windows.

  5. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    PubMed

    Baumgart, Julia Kathrin; Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Systematic literature review and meta-analysis. PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few included studies and corresponding low sample sizes. The meta-regression and pooled-data multiple regression analyses showed that being a man, having an amputation, not being tetraplegic, testing in a wheelchair ergometer and treadmill mode, were found to be favorable for high absolute and body-mass normalized VO2peak values. Furthermore, high body mass was favourable for high absolute VO2peak values and low body mass for high body-mass normalized VO2peak values. The highest VO2peak values were found in Nordic sit skiing, an endurance sport with continuously high physical efforts, and the lowest values in shooting, a sport with low levels of displacement, and in wheelchair rugby where mainly athletes with tetraplegia compete. However, VO2peak values need to be interpreted carefully in sports-disciplines with few included studies and large within-sports variation. Future studies should include detailed information on training status, sex, age, test mode, as well as the type and extent of disability in order to more precisely evaluate the effect of these factors on VO2peak.

  6. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis

    PubMed Central

    Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Background Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. Objectives To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Design Systematic literature review and meta-analysis. Data sources PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Eligibility criteria Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data synthesis Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Results Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few included studies and corresponding low sample sizes. The meta-regression and pooled-data multiple regression analyses showed that being a man, having an amputation, not being tetraplegic, testing in a wheelchair ergometer and treadmill mode, were found to be favorable for high absolute and body-mass normalized VO2peak values. Furthermore, high body mass was favourable for high absolute VO2peak values and low body mass for high body-mass normalized VO2peak values. Conclusion The highest VO2peak values were found in Nordic sit skiing, an endurance sport with continuously high physical efforts, and the lowest values in shooting, a sport with low levels of displacement, and in wheelchair rugby where mainly athletes with tetraplegia compete. However, VO2peak values need to be interpreted carefully in sports-disciplines with few included studies and large within-sports variation. Future studies should include detailed information on training status, sex, age, test mode, as well as the type and extent of disability in order to more precisely evaluate the effect of these factors on VO2peak. PMID:29474386

  7. How do cardiorespiratory fitness improvements vary with physical training modality in heart failure patients? A quantitative guide

    PubMed Central

    Smart, Neil A

    2013-01-01

    BACKGROUND: Peak oxygen consumption (VO2) is the gold standard measure of cardiorespiratory fitness and a reliable predictor of survival in chronic heart failure patients. Furthermore, any form of physical training usually improves cardiorespiratory fitness, although the magnitude of improvement in peak VO2 may vary across different training prescriptions. OBJECTIVE: To quantify, and subsequently rank, the magnitude of improvement in peak VO2 for different physical training prescriptions using data from published meta-analyses and randomized controlled trials. METHODS: Prospective randomized controlled parallel trials and meta-analyses of exercise training in chronic heart failure patients that provided data on change in peak VO2 for nine a priori comparative analyses were examined. RESULTS: All forms of physical training were beneficial, although the improvement in peak VO2 varied with modality. High-intensity interval exercise yielded the largest increase in peak VO2, followed in descending order by moderate-intensity aerobic exercise, functional electrical stimulation, inspiratory muscle training, combined aerobic and resistance training, and isolated resistance training. With regard to setting, the present study was unable to determine whether outpatient or unsupervised home exercise provided greater benefits in terms of peak VO2 improvment. CONCLUSIONS: Interval exercise is not suitable for all patients, especially the high-intensity variety; however, when indicated, this form of exercise should be adopted to optimize peak VO2 adaptations. Other forms of activity, such as functional electrical stimulation, may be more appropriate for patients who are not capable of high-intensity interval training, especially for severely deconditioned patients who are initially unable to exercise. PMID:24294043

  8. VO.sub.2 precipitates for self-protected optical surfaces

    DOEpatents

    Gea, Laurence A.; Boatner, Lynn A.

    1999-01-01

    A method for forming crystallographically coherent precipitates of vanadium dioxide in the near-surface region of sapphire and the resulting product is disclosed. Ions of vanadium and oxygen are stoichiometrically implanted into a sapphire substrate (Al.sub.2 O.sub.3), and subsequently annealed to form vanadium dioxide precipitates in the substrate. The embedded VO.sub.2 precipitates, which are three-dimensionally oriented with respect to the crystal axes of the Al.sub.2 O.sub.3 host lattice, undergo a first-order monoclinic-to-tetragonal (and also semiconducting-to-metallic) phase transition at .about.77.degree. C. This transformation is accompanied by a significant variation in the optical transmission of the implanted region and results in the formation of an optically active, thermally "switchable" surface region on Al.sub.2 O.sub.3.

  9. Two-Dimensional VO2 Mesoporous Microarrays for High-Performance Supercapacitor

    NASA Astrophysics Data System (ADS)

    Fan, Yuqi; Ouyang, Delong; Li, Bao-Wen; Dang, Feng; Ren, Zongming

    2018-05-01

    Two-dimensional (2D) mesoporous VO2 microarrays have been prepared using an organic-inorganic liquid interface. The units of microarrays consist of needle-like VO2 particles with a mesoporous structure, in which crack-like pores with a pore size of about 2 nm and depth of 20-100 nm are distributed on the particle surface. The liquid interface acts as a template for the formation of the 2D microarrays, as identified from the kinetic observation. Due to the mesoporous structure of the units and high conductivity of the microarray, such 2D VO2 microarrays exhibit a high specific capacitance of 265 F/g at 1 A/g and excellent rate capability (182 F/g at 10 A/g) and cycling stability, suggesting the effect of unique microstructure for improving the electrochemical performance.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Yong; Pan, Xuan; Bernussi, Ayrton A.

    We demonstrate that catalyst-assisted hydrogen spillover doping of VO{sub 2} thin films significantly alters the metal-insulator transition characteristics and stabilizes the metallic rutile phase at room temperature. With hydrogen inserted into the VO{sub 2} lattice, high resolution X-ray diffraction reveals expansion of the V-V chain separation when compared to the VO{sub 2}(R) phase. The donated free electrons, possibly from O-H bond formation, stabilize the VO{sub 2}(R) to low temperatures. By controlling the amount of dopants to obtain mixed insulating and metallic phases, VO{sub 2} resistivity can be continuously tuned until a critical condition is achieved that suppresses Fabry-Perot resonances. Ourmore » results demonstrate that hydrogen spillover is an effective technique to tune the electrical and optical properties of VO{sub 2} thin films.« less

  11. Ventilatory threshold may be a more specific measure of aerobic capacity than peak oxygen consumption rate in persons with stroke.

    PubMed

    Boyne, Pierce; Reisman, Darcy; Brian, Michael; Barney, Brian; Franke, Ava; Carl, Daniel; Khoury, Jane; Dunning, Kari

    2017-03-01

    After stroke, aerobic deconditioning can have a profound impact on daily activities. This is usually measured by the peak oxygen consumption rate achieved during exercise testing (VO2-peak). However, VO2-peak may be distorted by motor function. The oxygen uptake efficiency slope (OUES) and VO2 at the ventilatory threshold (VO2-VT) could more specifically assess aerobic capacity after stroke, but this has not been tested. To assess the differential influence of motor function on three measures of aerobic capacity (VO2-peak, OUES, and VO2-VT) and to evaluate the inter-rater reliability of VO2-VT determination post-stroke. Among 59 persons with chronic stroke, cross-sectional correlations with motor function (comfortable gait speed [CGS] and lower extremity Fugl-Meyer [LEFM]) were compared between the different aerobic capacity measures, after adjustment for covariates, in order to isolate any distorting effect of motor function. Reliability of VO2-VT determination between three raters was assessed with intra-class correlation (ICC). CGS was moderately correlated with VO2-peak (r = 0.52, p < 0.0001) and weakly correlated with OUES (r = 0.41, p = 0.002) and VO2-VT (r = 0.37, p = 0.01). LEFM was weakly correlated with VO2-peak (r = 0.26, p = 0.055) and very weakly correlated with OUES (r = 0.19, p = 0.17) and VO2-VT (r = 0.14, p = 0.31). Compared to VO2-peak, VO2-VT was significantly less correlated with CGS (r difference = -0.16, p = 0.02). Inter-rater reliability of VO2-VT determination was high (ICC: 0.93, 95% CI: 0.89-0.96). Motor dysfunction appears to artificially lower measured aerobic capacity. VO2-VT seemed to be less distorted than VO2-peak and had good inter-rater reliability, so it may provide more specific assessment of aerobic capacity post-stroke.

  12. Synthesis and structural characterization of the hexagonal anti-perovskite Na{sub 2}CaVO{sub 4}F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, Robert L., E-mail: rgreen@flpoly.org; Avdeev, Maxim; School of Chemistry, The University of Sydney, Sydney, NSW 2006

    The structural details of the ordered hexagonal oxyfluoride Na{sub 2}CaVO{sub 4}F prepared by solid-state synthesis using stoichiometric amounts of V{sub 2}O{sub 5}, CaCO{sub 3}, Na{sub 2}CO{sub 3} and NaF were characterized using high-resolution neutron powder diffraction. The structural changes between 25 °C and 750 °C revealed that the two structural subunits in this material behave different when heated: there is an expansion of the face-shared FNa{sub 4}Ca{sub 2} octahedra while the VO{sub 4} tetrahedra due to increased thermal disorder reveal marginal bond contractions. Bond valences and the global instability index point to significant structural disorder at 750 °C. - Graphicalmore » abstract: The structure of the novel oxyfluoride Na{sub 2}CaVO{sub 4}F is studied at room temperature and high-temperatures. The structure can be viewed as layers of compression and elongation of polyhedral subunits, which change as a function of temperature. - Highlights: • The novel oxyfluoride, Na{sub 2}CaVO{sub 4}F, is synthesized via solid-state method. • High-resolution neutron diffraction data is used to analyze the structure of Na{sub 2}CaVO{sub 4}F. • Structural subunits exhibit expansion and contraction with increasing temperature. • Higher temperatures increase instability within the structure of Na{sub 2}CaVO{sub 4}F.« less

  13. Oxygen consumption during functional electrical stimulation-assisted exercise in persons with spinal cord injury: implications for fitness and health.

    PubMed

    Hettinga, Dries M; Andrews, Brian J

    2008-01-01

    A lesion in the spinal cord leads in most cases to a significant reduction in active muscle mass, whereby the paralysed muscles cannot contribute to oxygen consumption (VO2) during exercise. Consequently, persons with spinal cord injury (SCI) can only achieve high VO2 values by excessively stressing the upper body musculature, which might increase the risk of musculoskeletal overuse injury. Alternatively, the muscle mass involved may be increased by using functional electrical stimulation (FES). FES-assisted cycling, FES-cycling combined with arm cranking (FES-hybrid exercise) and FES-rowing have all been suggested as candidates for cardiovascular training in SCI. In this article, we review the levels of VO2 (peak [VO2peak] and sub-peak [VO2sub-peak]) that have been reported for SCI subjects using these FES exercise modalities. A systematic literature search in MEDLINE, EMBASE, AMED, CINAHL, SportDiscus and the authors' own files revealed 35 studies that reported on 499 observations of VO2 levels achieved during FES-exercise in SCI. The results show that VO2peak during FES-rowing (1.98 L/min, n = 17; 24.1 mL/kg/min, n = 11) and FES-hybrid exercise (1.78 L/min, n = 67; 26.5 mL/kg/min, n = 35) is considerably higher than during FES-cycling (1.05 L/min, n = 264; 14.3 mL/kg/min, n = 171). VO2sub-peak values during FES-hybrid exercise were higher than during FES-cycling. FES-exercise training can produce large increases in VO2peak; the included studies report average increases of +11% after FES-rowing training, +12% after FES-hybrid exercise training and +28% after FES-cycling training. This review shows that VO2 during FES-rowing or FES-hybrid exercise is considerably higher than during FES-cycling. These observations are confirmed by a limited number of direct comparisons; larger studies to test the differences in effectiveness of the various types of FES-exercise as cardiovascular exercise are needed. The results to date suggest that FES-rowing and FES-hybrid are more suited for high-intensity, high-volume exercise training than FES-cycling. In able-bodied people, such exercise programmes have shown to result in superior health and fitness benefits. Future research should examine whether similar high-intensity and high-volume exercise programmes also give persons with SCI superior fitness and health benefits. This kind of research is very timely given the high incidence of physical inactivity-related health conditions in the aging SCI population.

  14. Validation of cardiac output using real-time measurement of oxygen consumption during cardiac catheterization in children under 3 years of age.

    PubMed

    Seckeler, Michael D; Hirsch, Russel; Beekman, Robert H; Goldstein, Bryan H

    2014-01-01

    To validate a method for determination of cardiac index (CI) using real-time measurement of oxygen consumption (VO2 ) in young children undergoing cardiac catheterization. Retrospective review comparing thermodilution cardiac index (TDCI) to CI calculated by the Fick equation using real-time measured VO2 (RT-VO2 ) and VO2 derived from 2 published predictive equations. Paired t-test and Bland-Altman analysis were used to compare TDCI to Fick CI. A survey to ascertain pediatric cardiac catheterization practices regarding VO2 determination was also conducted. Quaternary care children's hospital cardiac catheterization laboratory. Children <3 years old with structurally normal hearts undergoing cardiac catheterization under general anesthesia with at least one set of contemporaneous TDCI and RT-VO2 measurements. Thirty-six paired measurements of TDCI and RT-VO2 were made in 27 patients over a 2-year period. Indications for catheterization included congenital diaphragmatic hernia postrepair (n = 13), heart disease post-orthotopic heart transplant (n = 13), and suspected cardiomyopathy (n = 1). Mean age was 21.5 ± 8 months; median weight was 9.9 kg (IQR 8.57, 12.2). RT-VO2 was higher than VO2 predicted by the LaFarge equation (190 ± 31 vs. 173.8 ± 12.8 mL/min/m(2), P < .001), but there was no difference between TDCI and Fick CI calculated using VO2 from any method. Bland-Altman analysis showed excellent agreement between TDCI and Fick CI using RT-VO2 and VO2 predicted by the Lundell equation; Fick CI using VO2 predicted by the LaFarge equation showed fair agreement with TDCI. In children <3 years with a structurally normal heart, RT-VO2 generates highly accurate determinations of Fick CI as compared with TDCI. Additionally, in this population, VO2 derived from the LaFarge and Lundell equations generates accurate Fick CI compared with TDCI. Future studies are needed to identify factors associated with inaccurate VO2 generated from these predictive equations. © 2013 Wiley Periodicals, Inc.

  15. Tunable Picosecond Laser Pulses via the Contrast of Two Reverse Saturable Absorption Phases in a Waveguide Platform

    PubMed Central

    Tan, Yang; Chen, Lianwei; Wang, Dong; Chen, Yanxue; Akhmadaliev, Shavkat; Zhou, Shengqiang; Hong, Minghui; Chen, Feng

    2016-01-01

    How to enhance the optical nonlinearity of saturable absorption materials is an important question to improve the functionality of various applications ranging from the high power laser to photonic computational devices. We demonstrate the saturable absorption (SA) of VO2 film attributed to the large difference of optical nonlinearities between the two states of the phase-transition materials (VO2). Such VO2 film demonstrated significantly improved performance with saturation intensity higher than other existing ultrathin saturable absorbers by 3 orders due to its unique nonlinear optical mechanisms in the ultrafast phase change process. Owing to this feature, a Q-switched pulsed laser was fabricated in a waveguide platform, which is the first time to achieve picosecond pulse duration and maintain high peak power. Furthermore, the emission of this VO2 waveguide laser can be flexibly switched between the continuous-wave (CW) and pulsed operation regimes by tuning the temperature of the VO2 film, which enables VO2-based miniature laser devices with unique and versatile functions. PMID:27188594

  16. VO2 responses to intermittent swimming sets at velocity associated with VO2max.

    PubMed

    Libicz, Sebastien; Roels, Belle; Millet, Gregoire P

    2005-10-01

    While the physiological adaptations following endurance training are relatively well understood, in swimming there is a dearth of knowledge regarding the metabolic responses to interval training (IT). The hypothesis tested predicted that two different endurance swimming IT sets would induce differences in the total time the subjects swam at a high percentage of maximal oxygen consumption (VO(2)max). Ten trained triathletes underwent an incremental test to exhaustion in swimming so that the swimming velocity associated with VO(2)max (vVO(2)max) could be determined. This was followed by a maximal 400-m test and two intermittent sets at vVO(2)max: (a) 16 x 50 m with 15-s rest (IT(50)); (b) 8 x 100 m with 30-s rest (IT(100)). The times sustained above 95% VO(2)max (68.50 +/- 62.69 vs. 145.01 +/- 165.91 sec) and 95% HRmax (146.67 +/- 131.99 vs. 169.78 +/- 203.45 sec, p = 0.54) did not differ between IT(50) and IT(100)(values are mean +/- SD). In conclusion, swimming IT sets of equal time duration at vVO(2)max but of differing work-interval durations led to slightly different VO(2)and HR responses. The time spent above 95% of VO(2)max was twice as long in IT(100) as in IT (50), and a large variability between mean VO(2)and HR values was also observed.

  17. Shape-controlled synthesis and influence of W doping and oxygen nonstoichiometry on the phase transition of VO2

    PubMed Central

    Chen, Ru; Miao, Lei; Liu, Chengyan; Zhou, Jianhua; Cheng, Haoliang; Asaka, Toru; Iwamoto, Yuji; Tanemura, Sakae

    2015-01-01

    Monoclinic VO2(M) in nanostructure is a prototype material for interpreting correlation effects in solids with fully reversible phase transition and for the advanced applications to smart devices. Here, we report a facile one-step hydrothermal method for the controlled growth of single crystalline VO2(M/R) nanorods. Through tuning the hydrothermal temperature, duration of the hydrothermal time and W-doped level, single crystalline VO2(M/R) nanorods with controlled aspect ratio can be synthesized in large quantities, and the crucial parameter for the shape-controlled synthesis is the W-doped content. The dopant greatly promotes the preferential growth of (110) to form pure phase VO2(R) nanorods with high aspect ratio for the W-doped level = 2.0 at% sample. The shape-controlled process of VO2(M/R) nanorods upon W-doping are systematically studied. Moreover, the phase transition temperature (Tc) of VO2 depending on oxygen nonstoichiometry is investigated in detail. PMID:26373612

  18. The relation between knee muscle strength and performance tests in orienteering athletes.

    PubMed

    Çinar-Medeni, Özge; Colakoglu, Fatma F; Yüce, Koray; Ipekoğlu, Gökhan; Baltaci, Gul

    2016-11-01

    The aim of this study was to analyze the effect of knee muscle strength on performance tests in orienteers. Thirty-seven orienteers were voluntarily included in this study. Isokinetic knee flexor and extensor muscles' strength was assessed at 120°/s velocity for both "dominant leg" (DL) and "non-dominant leg" (NDL). "Single-legged hop test" (SLHT), "flamingo balance test" (FBT), "star excursion balance test" (SEBT), vertical jump-and-reach test (for anaerobic power), T-drill test and 20-meter shuttle run test (for aerobic power) were carried out. Correlation and regression analyses were performed on the data. VO2max levels showed moderate correlations with DL's "flexor peak torque" (FPT) and NDL's "extensor peak torque" (EPT) and FPT values respectively (r=0.49, r=0.38, r=0.58). FPT of NDL was a predictor of VO2max level (R2=0.33). Anaerobic power has a relationship with EPT of NDL (r=0.43) and T-drill test with EPT and FPT values of both DL and NDL respectively (r=-0.35, r=-0.63, r=-0.53, r=-0.58). EPT of NDL was a predictor for anaerobic power (R2=0.19) and FPT of DL for agility (R2=0.40). Nonparametric linear regression results showed that EPT is a predictor in DL (median slope=-0.71, P=0.01), and FPT in NDL (median slope=-0.90, P=0.006) for FBT. FPT was a predictor of SEBT scores for both legs (0.13

  19. Astroinformatics as a New Research Field. UkrVO Astroinformation Resources: Tasks and Prospective

    NASA Astrophysics Data System (ADS)

    Vavilova, I. B.

    The data-oriented astronomy has allowed classifying the Astroinformatics as a new academic research field, which covers various multi-disciplinary applications of the e-Astronomy. Among them are the data modeling, data mining, metadata standards development, data access, digital astronomical databases, image archives and visualization, machine learning, statistics and other computational methods and software for work with astronomical survey and catalogues with their teta- topeta-scale astroinformation resource. In this review we describe briefly the astroinformatics applications and software/services performed for different astronomical tasks in frame of the VIrtual Roentgen and Gamma Observatory (VIRGO) and Ukrainian VirtualObservatory (UkrVO). Among them there are projects based on the archival space-born data of X-ray and gamma space observatories and on the Joint Digitized Archive (JDA) database of astroplate network collections. The UkrVO JDA DR1 deals with the star catalogues (FON, Polar zone, open clusters, GRB star fields) as well as the UkrVO JDA DR2 deals with the Solar System bodies (giant and small planets, satellites, astronomical heritage images).

  20. Physical activity as a long-term predictor of peak oxygen uptake: the HUNT Study.

    PubMed

    Aspenes, Stian Thoresen; Nauman, Javaid; Nilsen, Tom Ivar Lund; Vatten, Lars Johan; Wisløff, Ulrik

    2011-09-01

    A physically active lifestyle and a relatively high level of cardiorespiratory fitness are important for longevity and long-term health. No population-based study has prospectively assessed the association of physical activity levels with long-term peak oxygen uptake (VO(2peak)). 1843 individuals (906 women and 937 men) who were between 18 and 66 yr at baseline and were free from known lung or heart diseases at both baseline (1984-1986) and follow-up (2006-2008) were included in the study. Self-reported physical activity was recorded at both occasions, and VO(2peak) was measured at follow-up. The association of physical activity levels and VO(2peak) was adjusted for age, level of education, smoking status, and weight change from baseline to follow-up, using ANCOVA statistics. The level of physical activity at baseline was strongly associated with VO(2peak) at follow-up 23 yr later in both men and women (Ptrends < 0.001). Compared with individuals who were inactive at baseline, women and men who were highly active at baseline had higher (3.3 and 4.6 mL·kg(-1)·min(-1)) VO(2peak) at follow-up. Women who were inactive at baseline but highly active at follow-up had 3.7 mL·kg(-1)·min(-1) higher VO(2peak) compared with women who were inactive both at baseline and at follow-up. The corresponding comparison in men showed a difference of 5.2 mL·kg(-1)·min(-1) (95% confidence interval = 3.1-7.3) in VO(2peak). Physical activity level at baseline was positively associated with directly measured cardiorespiratory fitness (VO(2peak)) 23 yr later. People who changed from low to high activity during the observation period had substantially higher V˙O(2peak) at follow-up compared with people whose activity remained low.

  1. New intelligent multifunctional SiO2/VO2 composite films with enhanced infrared light regulation performance, solar modulation capability, and superhydrophobicity

    NASA Astrophysics Data System (ADS)

    Wang, Chao; Zhao, Li; Liang, Zihui; Dong, Binghai; Wan, Li; Wang, Shimin

    2017-12-01

    Highly transparent, energy-saving, and superhydrophobic nanostructured SiO2/VO2 composite films have been fabricated using a sol-gel method. These composite films are composed of an underlying infrared (IR)-regulating VO2 layer and a top protective layer that consists of SiO2 nanoparticles. Experimental results showed that the composite structure could enhance the IR light regulation performance, solar modulation capability, and hydrophobicity of the pristine VO2 layer. The transmittance of the composite films in visible region (Tlum) was higher than 60%, which was sufficient to meet the requirements of glass lighting. Compared with pristine VO2 films and tungsten-doped VO2 film, the near IR control capability of the composite films was enhanced by 13.9% and 22.1%, respectively, whereas their solar modulation capability was enhanced by 10.9% and 22.9%, respectively. The water contact angles of the SiO2/VO2 composite films were over 150°, indicating superhydrophobicity. The transparent superhydrophobic surface exhibited a high stability toward illumination as all the films retained their initial superhydrophobicity even after exposure to 365 nm light with an intensity of 160 mW.cm-2 for 10 h. In addition, the films possessed anti-oxidation and anti-acid properties. These characteristics are highly advantageous for intelligent windows or solar cell applications, given that they can provide surfaces with anti-fogging, rainproofing, and self-cleaning effects. Our technique offers a simple and low-cost solution to the development of stable and visible light transparent superhydrophobic surfaces for industrial applications.

  2. High-intensity Interval Training Dosage for Heart Failure and Coronary Artery Disease Cardiac Rehabilitation. A Systematic Review and Meta-analysis.

    PubMed

    Ballesta García, Ismael; Rubio Arias, Jacobo Ángel; Ramos Campo, Domingo Jesús; Martínez González-Moro, Ignacio; Carrasco Poyatos, María

    2018-04-09

    High-interval intensity training (HIT) has been suggested to improve peak VO 2 in cardiac rehabilitation programs. However, the optimal HIT protocol is unknown. The objective of this study was to identify the most effective doses of HIT to optimize peak VO 2 in coronary artery disease (CAD) and heart failure (HF) patients. A search was conducted in 6 databases (MEDLINE, Web of Science, LILACS, CINAHL, Academic Search Complete, and SportDiscus). Studies using a HIT protocol in CAD or HF patients and measuring peak VO 2 were included. The PEDro Scale and Cochrane Collaboration tools were used. Analyses reported significant improvements in peak VO 2 after HIT in both diseases (P = .000001), with a higher increase in HF patients (P = .03). Nevertheless, in HF patients, there were no improvements when the intensity recovery was ≤ 40% of peak VO 2 (P = .19) and the frequency of training was ≤ 2 d/wk (P = .07). There were significant differences regarding duration in CAD patients, with greater improvements in peak VO 2 when the duration was < 12 weeks (P = .05). In HF, programs lasting < 12 weeks did not significantly improve peak VO 2 (P = .1). The HIT is an effective method for improving peak VO 2 in HF and CAD, with a significantly greater increase in HF patients. The recovery intervals should be active and be between 40% and 60% of peak VO 2 in HF patients. Training frequency should be ≥ 2 d/wk for CAD patients and ≥ 3 d/wk for HF patients. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. Physicochemical characterization of point defects in fluorine doped tin oxide films

    NASA Astrophysics Data System (ADS)

    Akkad, Fikry El; Joseph, Sudeep

    2012-07-01

    The physical and chemical properties of spray deposited FTO films are studied using FESEM, x-ray diffraction (XRD), x-ray photoelectron spectroscopy (XPS), electrical and optical measurements. The results of XRD measurements showed that the films are polycrystalline (grain size 20-50 nm) with Rutile structure and mixed preferred orientation along the (200) and (110) planes. An angular shift of the XRD peaks after F-doping is observed and interpreted as being due to the formation of substitutional fluorine defects (FO) in presence of high concentration of oxygen vacancies (VO) that are electrically neutral. The electrical neutrality of oxygen vacancies is supported by the observation that the electron concentration n is two orders of magnitude lower than the VO concentration calculated from chemical analyses using XPS measurements. It is shown that an agreement between XPS, XRD, and Hall effect results is possible provided that the degree of deviation from stoichiometry is calculated with the assumption that the major part of the bulk carbon content is involved in O-C bonds. High temperature thermal annealing is found to cause an increase in the FO concentration and a decrease in both n and VO concentrations with the increase of the annealing temperature. These results could be interpreted in terms of a high temperature chemical exchange reaction between the SnO2 matrix and a precipitated fluoride phase. In this reaction, fluorine is released to the matrix and Sn is trapped by the fluoride phase, thus creating substitutional fluorine FO and tin vacancy VSn defects. The enthalpy of this reaction is determined to be approximately 2.4 eV while the energy of formation of a VSn through the migration of SnSn host atom to the fluoride phase is approximately 0.45 eV.

  4. The preparation of a plasmonically resonant VO2 thermochromic pigment.

    PubMed

    Bai, Huaping; Cortie, Michael B; Maaroof, Abbas I; Dowd, Annette; Kealley, Catherine; Smith, Geoffrey B

    2009-02-25

    Vanadium dioxide (VO(2)) undergoes a reversible metal-insulator transition, normally at approximately 68 degrees C. While the properties of continuous semi-transparent coatings of VO(2) are well known, there is far less information available concerning the potential use of discrete VO(2) nanoparticles as a thermochromic pigment in opaque coatings. Individual VO(2) nanoparticles undergo a localized plasmon resonance with near-infrared light at about 1100 nm and this resonance can be switched on and off by simply varying the temperature of the system. Therefore, incorporation of VO(2) nanoparticles into a coating system imbues the coating with the ability to self-adaptively modulate its own absorptive efficiency in the near-infrared. Here we examine the magnitude and control of this phenomenon. Prototype coatings are described, made using VO(2) powder produced by an improved process. The materials are characterized using calorimetry, x-ray diffraction, high-resolution scanning electron microscopy, transmission electron microscopy, and by measurement of optical properties.

  5. Tailoring of the thermomechanical performance of VO2 nanowire bimorph actuators by ion implantation

    NASA Astrophysics Data System (ADS)

    Karl, H.; Peyinghaus, S. C.

    2015-12-01

    Vanadium dioxide VO2 nanowire bimorph actuators work on the basis of the large abrupt length change at the metal-insulator phase transition (MIT). A key parameter for the bimorph performance and efficiency is the bending curvature and the width of the temperature hysteresis of the MIT which is inherently large for single domain VO2 metal side coated nanowires. In this work we present single-clamped Ir side coated VO2 bimorphs which show unprecedented high bending curvatures of up to 105 m-1 and new type of side ion-implanted VO2 nanowire bimorph actuators with a nearly completely suppressed temperature hysteresis. It is assumed that ion-beam induced radiation defects in the VO2 crystal structure act as nucleation sites for the MIT. Moreover it will be shown that mechanical strain intentionally built-in during VO2 nanowire bimorph fabrication allows to direct phase transformation via a strain stabilized metastable phase and thus allows to control bending response on temperature change.

  6. Change in VO2max and time trial performance in response to high-intensity interval training prescribed using ventilatory threshold.

    PubMed

    Astorino, Todd A; deRevere, Jamie; Anderson, Theodore; Kellogg, Erin; Holstrom, Patrick; Ring, Sebastian; Ghaseb, Nicholas

    2018-06-19

    Completion of high-intensity interval training (HIIT) leads to significant increases in maximal oxygen uptake (VO 2max ) and oxidative capacity. However, individual responses to HIIT have been identified as approximately 20-40% of individuals show no change in VO 2max , which may be due to the relatively homogeneous approach to implementing HIIT. This study tested the effects of HIIT prescribed using ventilatory threshold (VT) on changes in VO 2max and cycling performance. Fourteen active men and women (age and VO 2max  = 27 ± 8 year and 38 ± 4 mL/kg/min) underwent nine sessions of HIIT, and 14 additional men and women (age and VO 2max  = 22 ± 3 year and 40 ± 5 mL/kg/min) served as controls. Training was performed on a cycle ergometer at a work rate equal to 130%VT and consisted of eight to ten 1 min bouts interspersed with 75 s of recovery. At baseline and post-testing, they completed progressive cycling to exhaustion to determine VO 2max , and on a separate day, a 5 mile cycling time trial. Compared to the control group, HIIT led to significant increases in VO 2max (6%, p = 0.007), cycling performance (2.5%, p = 0.003), and absolute VT (9 W, p = 0.005). However, only 57% of participants revealed meaningful increases in VO 2max and cycling performance in response to training, and two showed no change in either outcome. A greater volume of HIIT may be needed to maximize the training response for all individuals.

  7. Arm crank ergometry improves cardiovascular disease risk factors and community mobility independent of body composition in high motor complete spinal cord injury.

    PubMed

    Bresnahan, James J; Farkas, Gary J; Clasey, Jody L; Yates, James W; Gater, David R

    2018-01-15

    Evaluate the effect of aerobic exercise using arm crank ergometry (ACE) in high motor complete (ISNCSCI A/B) spinal cord injury (SCI) as primarily related to cardiovascular disease (CVD) risk factors and functional mobility and secondarily to body composition and metabolic profiles. Longitudinal interventional study at an academic medical center. Ten previously untrained participants (M8/F2, Age 36.7 y ± 10.1, BMI 24.5 ± 6.0) with high motor complete SCI (C7-T5) underwent ACE exercise training 30 minutes/day × 3 days/week for 10 weeks at 70% VO 2Peak . Primary outcome measures were pre- and post-intervention changes in markers of cardiovascular fitness (graded exercise testing (GXT): VO 2 , VO 2Peak , respiratory quotient [RQ], GXT time, peak power, and energy expenditure [EE]) and community mobility (time to traverse a 100ft-5° ramp, and 12-minute WC propulsion test). Secondary outcome measures were changes in body composition and metabolic profiles (fasting and area under the curve for glucose and insulin, homeostasis model assessment [HOMA] for %β-cell activity [%β], %insulin sensitivity [%S], and insulin resistance [IR], and Matsuda Index [ISI Matsuda ]). Resting VO 2 , relative VO 2Peak , absolute VO 2Peak , peak power, RQ, 12-minute WC propulsion, fasting insulin, fasting G:I ratio, HOMA-%S, and HOMA-IR all significantly improved following intervention (P < 0.05). There were no changes in body composition (P>0.05). Ten weeks of ACE at 70% VO 2Peak in high motor complete SCI improves aerobic capacity, community mobility, and metabolic profiles independent of changes in body composition.

  8. VO{sub 2} precipitates for self-protected optical surfaces

    DOEpatents

    Gea, L.A.; Boatner, L.A.

    1999-03-23

    A method for forming crystallographically coherent precipitates of vanadium dioxide in the near-surface region of sapphire and the resulting product is disclosed. Ions of vanadium and oxygen are stoichiometrically implanted into a sapphire substrate (Al{sub 2}O{sub 3}), and subsequently annealed to form vanadium dioxide precipitates in the substrate. The embedded VO{sub 2} precipitates, which are three-dimensionally oriented with respect to the crystal axes of the Al{sub 2}O{sub 3} host lattice, undergo a first-order monoclinic-to-tetragonal (and also semiconducting-to-metallic) phase transition at ca. 77 C. This transformation is accompanied by a significant variation in the optical transmission of the implanted region and results in the formation of an optically active, thermally ``switchable`` surface region on Al{sub 2}O{sub 3}. 5 figs.

  9. Time to Exhaustion at the VO2max Velocity in Swimming: A Review

    PubMed Central

    Fernandes, Ricardo J.; Vilas-Boas, J. Paulo

    2012-01-01

    The aim of this study was to present a review on the time to exhaustion at the minimum swimming velocity corresponding to maximal oxygen consumption (TLim-vVO2max). This parameter is critical both for the aerobic power and the lactate tolerance bioenergetical training intensity zones, being fundamental to characterize it, and to point out its main determinants. The few number of studies conducted in this topic observed that swimmers were able to maintain an exercise intensity corresponding to maximal aerobic power during 215 to 260 s (elite swimmers), 230 to 260 s (high level swimmers) and 310 to 325 s (low level swimmers), and no differences between genders were reported. TLim-vVO2max main bioenergetic and functional determinants were swimming economy and VO2 slow component (direct relationship), and vVO2max, velocity at anaerobic threshold and blood lactate production (inverse relationship); when more homogeneous groups of swimmers were analysed, the inverse correlation value between TLim-vVO2max and vVO2max was not so evident. In general, TLim-vVO2max was not related to VO2max. TLim-vVO2max seems also to be influenced by stroking parameters, with a direct relationship to stroke length and stroke index, and an inverse correlation with stroke rate. Assessing TLim-vVO2max, together with the anaerobic threshold and the biomechanical general parameters, will allow a larger spectrum of testing protocols application, helping to build more objective and efficient training programs. PMID:23486651

  10. Usefulness of peak exercise oxygen consumption and the heart failure survival score to predict survival in patients >65 years of age with heart failure.

    PubMed

    Parikh, Mona N; Lund, Lars H; Goda, Ayumi; Mancini, Donna

    2009-04-01

    Peak exercise oxygen consumption (Vo(2)) and the Heart Failure (HF) Survival Score (HFSS) were developed in middle-aged patient cohorts referred for heart transplantation with HF. The prognostic value of Vo(2) in patients >65 years has not been well studied. Accordingly, the prognostic value of peak Vo(2) was evaluated in these patients with HF. A retrospective analysis of 396 patients with HF >65 years with cardiopulmonary exercise testing was performed. Peak Vo(2) and components of the HFSS (presence of coronary artery disease, left ventricular ejection fraction, heart rate, mean arterial blood pressure, presence of intraventricular conduction defects, and serum sodium) were collected. Follow-up averaged 1,038 +/- 983 days. Outcome events were defined as death, implantation of a left ventricular assist device, or urgent transplantation. Patients were divided into risk strata for peak Vo(2) and HFSS based on previous cut-off points. Survival curves were derived using Kaplan-Meier analysis and compared using log-rank analysis. Survival differed markedly by Vo(2) stratum (p <0.0001), with significantly better survival rates for the low- (>14 ml/kg/min) versus medium- (10 to 14 ml/kg/min), low- versus high- (<10 ml/kg/min), and medium- versus high-risk strata (all p <0.05). Survival also differed markedly by HFSS stratum (p <0.0001), with significantly better survival rates for the low- (> or =8.10) versus medium- (7.20 to 8.09), low- versus high- (< or =7.19), and medium- versus high-risk strata (all p <0.0001). In conclusion, peak Vo(2) and the HFSS were both excellent parameters to predict survival in patients >65 years with HF.

  11. Interval training at 95% and 100% of the velocity at VO2 max: effects on aerobic physiological indexes and running performance.

    PubMed

    Denadai, Benedito S; Ortiz, Marcelo J; Greco, Camila C; de Mello, Marco T

    2006-12-01

    The objective of this study was to analyze the effect of two different high-intensity interval training (HIT) programs on selected aerobic physiological indices and 1500 and 5000 m running performance in well-trained runners. The following tests were completed (n=17): (i) incremental treadmill test to determine maximal oxygen uptake (VO2 max), running velocity associated with VO2 max (vVO2 max), and the velocity corresponding to 3.5 mmol/L of blood lactate concentration (vOBLA); (ii) submaximal constant-intensity test to determine running economy (RE); and (iii) 1500 and 5000 m time trials on a 400 m track. Runners were then randomized into 95% vVO2 max or 100% vVO2 max groups, and undertook a 4 week training program consisting of 2 HIT sessions (performed at 95% or 100% vVO2 max, respectively) and 4 submaximal run sessions per week. Runners were retested on all parameters at the completion of the training program. The VO2 max values were not different after training for both groups. There was a significant increase in post-training vVO2 max, RE, and 1500 m running performance in the 100% vVO2 max group. The vOBLA and 5000 m running performance were significantly higher after the training period for both groups. We conclude that vOBLA and 5000 m running performance can be significantly improved in well-trained runners using a 4 week training program consisting of 2 HIT sessions (performed at 95% or 100% vVO2 max) and 4 submaximal run sessions per week. However, the improvement in vVO2 max, RE, and 1500 m running performance seems to be dependent on the HIT program at 100% vVO2 max.

  12. The effects of breathing a helium-oxygen gas mixture on maximal pulmonary ventilation and maximal oxygen consumption during exercise in acute moderate hypobaric hypoxia.

    PubMed

    Ogawa, Takeshi; Calbet, Jose A L; Honda, Yasushi; Fujii, Naoto; Nishiyasu, Takeshi

    2010-11-01

    To test the hypothesis that maximal exercise pulmonary ventilation (VE max) is a limiting factor affecting maximal oxygen uptake (VO2 max) in moderate hypobaric hypoxia (H), we examined the effect of breathing a helium-oxygen gas mixture (He-O(2); 20.9% O(2)), which would reduce air density and would be expected to increase VE max. Fourteen healthy young male subjects performed incremental treadmill running tests to exhaustion in normobaric normoxia (N; sea level) and in H (atmospheric pressure equivalent to 2,500 m above sea level). These exercise tests were carried out under three conditions [H with He-O(2), H with normal air and N] in random order. VO2 max and arterial oxy-hemoglobin saturation (SaO(2)) were, respectively, 15.2, 7.5 and 4.0% higher (all p < 0.05) with He-O(2) than with normal air (VE max, 171.9 ± 16.1 vs. 150.1 ± 16.9 L/min; VO2 max, 52.50 ± 9.13 vs. 48.72 ± 5.35 mL/kg/min; arterial oxyhemoglobin saturation (SaO(2)), 79 ± 3 vs. 76 ± 3%). There was a linear relationship between the increment in VE max and the increment in VO2 max in H (r = 0.77; p < 0.05). When subjects were divided into two groups based on their VO2 max, both groups showed increased VE max and SaO(2) in H with He-O(2), but VO2 max was increased only in the high VO2 max group. These findings suggest that in acute moderate hypobaric hypoxia, air-flow resistance can be a limiting factor affecting VE max; consequently, VO2 max is limited in part by VE max especially in subjects with high VO2 max.

  13. New intelligent multifunctional SiO2/VO2 composite films with enhanced infrared light regulation performance, solar modulation capability, and superhydrophobicity.

    PubMed

    Wang, Chao; Zhao, Li; Liang, Zihui; Dong, Binghai; Wan, Li; Wang, Shimin

    2017-01-01

    Highly transparent, energy-saving, and superhydrophobic nanostructured SiO 2 /VO 2 composite films have been fabricated using a sol-gel method. These composite films are composed of an underlying infrared (IR)-regulating VO 2 layer and a top protective layer that consists of SiO 2 nanoparticles. Experimental results showed that the composite structure could enhance the IR light regulation performance, solar modulation capability, and hydrophobicity of the pristine VO 2 layer. The transmittance of the composite films in visible region ( T lum ) was higher than 60%, which was sufficient to meet the requirements of glass lighting. Compared with pristine VO 2 films and tungsten-doped VO 2 film, the near IR control capability of the composite films was enhanced by 13.9% and 22.1%, respectively, whereas their solar modulation capability was enhanced by 10.9% and 22.9%, respectively. The water contact angles of the SiO 2 /VO 2 composite films were over 150°, indicating superhydrophobicity. The transparent superhydrophobic surface exhibited a high stability toward illumination as all the films retained their initial superhydrophobicity even after exposure to 365 nm light with an intensity of 160 mW . cm -2 for 10 h. In addition, the films possessed anti-oxidation and anti-acid properties. These characteristics are highly advantageous for intelligent windows or solar cell applications, given that they can provide surfaces with anti-fogging, rainproofing, and self-cleaning effects. Our technique offers a simple and low-cost solution to the development of stable and visible light transparent superhydrophobic surfaces for industrial applications.

  14. New intelligent multifunctional SiO2/VO2 composite films with enhanced infrared light regulation performance, solar modulation capability, and superhydrophobicity

    PubMed Central

    Wang, Chao; Zhao, Li; Liang, Zihui; Dong, Binghai; Wan, Li; Wang, Shimin

    2017-01-01

    Abstract Highly transparent, energy-saving, and superhydrophobic nanostructured SiO2/VO2 composite films have been fabricated using a sol–gel method. These composite films are composed of an underlying infrared (IR)-regulating VO2 layer and a top protective layer that consists of SiO2 nanoparticles. Experimental results showed that the composite structure could enhance the IR light regulation performance, solar modulation capability, and hydrophobicity of the pristine VO2 layer. The transmittance of the composite films in visible region (T lum) was higher than 60%, which was sufficient to meet the requirements of glass lighting. Compared with pristine VO2 films and tungsten-doped VO2 film, the near IR control capability of the composite films was enhanced by 13.9% and 22.1%, respectively, whereas their solar modulation capability was enhanced by 10.9% and 22.9%, respectively. The water contact angles of the SiO2/VO2 composite films were over 150°, indicating superhydrophobicity. The transparent superhydrophobic surface exhibited a high stability toward illumination as all the films retained their initial superhydrophobicity even after exposure to 365 nm light with an intensity of 160 mW.cm−2 for 10 h. In addition, the films possessed anti-oxidation and anti-acid properties. These characteristics are highly advantageous for intelligent windows or solar cell applications, given that they can provide surfaces with anti-fogging, rainproofing, and self-cleaning effects. Our technique offers a simple and low-cost solution to the development of stable and visible light transparent superhydrophobic surfaces for industrial applications. PMID:28970866

  15. Metabolic responses associated with deer hunting.

    PubMed

    Peterson, A T; Steffen, J; Terry, L; Davis, J; Porcari, J P; Foster, C

    1999-12-01

    Deer hunting is a popular recreational activity with a high rate of cardiovascular events. Previous studies have demonstrated large HR responses during deer hunting. This study compared the HR and metabolic costs of maximal treadmill (TM) exercise with those of hiking while deer hunting and while dragging a deer. Healthy male volunteers (N = 16) performed a maximal TM exercise test, a 0.8-km hiking test, and a 0.4-km dragging test over lightly rolling terrain. VO2 was measured by portable spirometry and HR by radiotelemetry. HR averaged 74.0 +/- 7.0% and 89.1 +/- 4.5% of peak TM HR during the hike and drag, respectively. The peak HR observed during hiking and dragging was 83.2 +/- 6.0% and 94.9 +/- 4.2% of peak TM HR, respectively. VO2 averaged 62.2 +/- 15.8% and achieved a peak of 77.2 +/- 19.0% of TM VO2 while hiking. This corresponded to 86.8 +/- 17.3% and 108.1 +/- 22.3% of ventilatory threshold (VT), respectively. VO2 averaged 72.3 +/- 21.0% and achieved a peak of 91.2 +/- 21.4% of peak TM VO2 while dragging the deer. This corresponded to 101.5 +/- 27.7% and 128.5 +/- 26.8% of VT, respectively. The VO2/HR relationship showed significant (P < 0.05) difference between the dragging test and the TM test with a disproportionately high HR. The VO2/HR relationship between the hiking and TM tests was comparable. In part, the previously described large HR responses and high rate of cardiovascular complications associated with deer hunting may attributable to the elevated metabolic costs of associated activities.

  16. Influence of work-interval intensity and duration on time spent at a high percentage of VO2max during intermittent supramaximal exercise.

    PubMed

    Wakefield, Benjamin R; Glaister, Mark

    2009-12-01

    The purpose of this study was to examine the effect of work-interval duration (WID) and intensity on the time spent at, or above, 95% VO2max (T95 VO2max) during intermittent bouts of supramaximal exercise. Over a 5-week period, 7 physically active men with a mean (+/-SD) age, height, body mass, and VO2max of 22 +/- 5 years, 181.5 +/- 5.6 cm, 86.4 +/- 11.4 kg, and 51.5 +/- 1.5 ml.kg-1.min-1, respectively, attended 7 testing sessions. After completing a submaximal incremental test on a treadmill to identify individual oxygen uptake/running velocity relationships, subjects completed a maximal incremental test to exhaustion to VO2max and subsequently (from the aforementioned relationship) the minimum velocity required to elicit VO2max (vVO2max). In a random order, subjects then carried out 3 intermittent runs to exhaustion at both 105% and 115% vVO2max. Each test used a different WID (20 s, 25 s, or 30 s) interspersed with 20-second passive recovery periods. Results revealed no significant difference in T95 vVO2max for intermittent runs at 105% versus 115% vVO2max (p = 0.142). There was, however, a significant effect (p < 0.001) of WID on T95 VO2max, with WIDs of 30 seconds enabling more time relative to WIDs of 20 seconds (p = 0.018) and 25 seconds (p = 0.009). Moreover, there was an interaction between intensity and duration such that the effect of WID was magnified at the lower exercise intensity (p = 0.046). In conclusion, despite a number of limitations, the results of this investigation suggest that exercise intensities of approximately 105% vVO2max combined with WIDs greater than 25 seconds provide the best way of optimizing T95 VO2max when using fixed 20-second stationary rest periods.

  17. Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training.

    PubMed

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael M; Namm, Samantha; Fischer, Anthony; Wood, Kimi A

    2018-01-01

    Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. Participants included 30 active men and women (mean age and VO2max=22.9±5.4 years and 39.6±5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max=25.7±4.5 years and 40.7±5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110%PPO. Data demonstrated significant improvements in VO2max (2.71±0.63 L/min to 2.86±0.63 L/min, P<0.001) and COmax (20.0±3.1 L/min to 21.7±3.2 L/min, P=0.04) via HIIT that were not exhibited in CON. Maximal SV was increased in HIIT (P=0.04) although there was no change in maximal HR (P=0.57). The increase in VO2max seen in response to ten sessions of HIIT is due to improvements in oxygen delivery.

  18. Oxygen consumption of the chicken embryo: interaction between temperature and oxygenation.

    PubMed

    Mortola, Jacopo P; Labbè, Katherine

    2005-03-01

    We measured the effects of hypoxia and changes in ambient temperature (T) on the oxygen consumption (VO2) of chicken embryos at embryonic days 11, 16 and 20 (E11, E16 and E20, respectively), and post-hatching day 1 (H1). Between 30 and 39 degrees C, at E11 and E16, VO2 changed linearly with T, as in ectothermic animals, with a Q10 of about 2.1. At E20, VO2 did not significantly change with T, indicating the onset of endothermy. At H1, a drop in T increased VO2, a clear thermogenic response. Hypoxia (11% O2 for 30 min) decreased VO2, by an amount that varied with T and age. At H1, hypoxia lowered VO2 especially at low T. At E20, hypoxic hypometabolism was similar at all T. At E11 and E16, hypoxia lowered VO2 only at the higher T. In fact, at E11, with T=39 degrees C even a modest hypoxia (15-18% O2) decreased VO2. Upon return to normoxia after 40 min of 11% O2, VO2 did not rise above the pre-hypoxic level, indicating that the hypometabolism during hypoxia did not generate an O2 debt. At E11, during modest hypoxia (16% O2) at 36 degrees C, the drop in VO2 was lifted by raising the T to 39 degrees C, suggesting that the hypoxic hypometabolism at 36 degrees C was not due to O2-supply limitation. In conclusion, the hypometabolic effects of hypoxia on the chicken embryo's VO2 depend on the development of the thermogenic ability, occurring predominantly at high T during the early (ectothermic phase) and at low T during the late (endothermic) phase. At E11, both low T and low oxygen force VO2 to drop. However, at a near-normal T, modest hypoxia promotes a hypometabolic response with the characteristics of regulated O2 conformism.

  19. Effects of beta-alanine supplementation and high-intensity interval training on endurance performance and body composition in men; a double-blind trial.

    PubMed

    Smith, Abbie E; Walter, Ashley A; Graef, Jennifer L; Kendall, Kristina L; Moon, Jordan R; Lockwood, Christopher M; Fukuda, David H; Beck, Travis W; Cramer, Joel T; Stout, Jeffrey R

    2009-02-11

    Intermittent bouts of high-intensity exercise result in diminished stores of energy substrates, followed by an accumulation of metabolites, promoting chronic physiological adaptations. In addition, beta-alanine has been accepted has an effective physiological hydrogen ion (H+) buffer. Concurrent high-intensity interval training (HIIT) and beta-alanine supplementation may result in greater adaptations than HIIT alone. The purpose of the current study was to evaluate the effects of combining beta-alanine supplementation with high-intensity interval training (HIIT) on endurance performance and aerobic metabolism in recreationally active college-aged men. Forty-six men (Age: 22.2 +/- 2.7 yrs; Ht: 178.1 +/- 7.4 cm; Wt: 78.7 +/- 11.9; VO2peak: 3.3 +/- 0.59 l.min-1) were assessed for peak O2 utilization (VO2peak), time to fatigue (VO2TTE), ventilatory threshold (VT), and total work done at 110% of pre-training VO2peak (TWD). In a double-blind fashion, all subjects were randomly assigned into one either a placebo (PL - 16.5 g dextrose powder per packet; n = 18) or beta-alanine (BA - 1.5 g beta-alanine plus 15 g dextrose powder per packet; n = 18) group. All subjects supplemented four times per day (total of 6 g/day) for the first 21-days, followed by two times per day (3 g/day) for the subsequent 21 days, and engaged in a total of six weeks of HIIT training consisting of 5-6 bouts of a 2:1 minute cycling work to rest ratio. Significant improvements in VO2peak, VO2TTE, and TWD after three weeks of training were displayed (p < 0.05). Increases in VO2peak, VO2TTE, TWD and lean body mass were only significant for the BA group after the second three weeks of training. The use of HIIT to induce significant aerobic improvements is effective and efficient. Chronic BA supplementation may further enhance HIIT, improving endurance performance and lean body mass.

  20. Two-Dimensional SiO2/VO2 Photonic Crystals with Statically Visible and Dynamically Infrared Modulated for Smart Window Deployment.

    PubMed

    Ke, Yujie; Balin, Igal; Wang, Ning; Lu, Qi; Tok, Alfred Iing Yoong; White, Timothy J; Magdassi, Shlomo; Abdulhalim, Ibrahim; Long, Yi

    2016-12-07

    Two-dimensional (2D) photonic structures, widely used for generating photonic band gaps (PBG) in a variety of materials, are for the first time integrated with the temperature-dependent phase change of vanadium dioxide (VO 2 ). VO 2 possesses thermochromic properties, whose potential remains unrealized due to an undesirable yellow-brown color. Here, a SiO 2 /VO 2 core/shell 2D photonic crystal is demonstrated to exhibit static visible light tunability and dynamic near-infrared (NIR) modulation. Three-dimensional (3D) finite difference time domain (FDTD) simulations predict that the transmittance can be tuned across the visible spectrum, while maintaining good solar regulation efficiency (ΔT sol = 11.0%) and high solar transmittance (T lum = 49.6%). Experiments show that the color changes of VO 2 films are accompanied by NIR modulation. This work presents a novel way to manipulate VO 2 photonic structures to modulate light transmission as a function of wavelength at different temperatures.

  1. High-performance porous spherical or octapod-like single-crystalline BiVO4 photocatalysts for the removal of phenol and methylene blue under visible-light illumination.

    PubMed

    Jiang, Haiyan; Meng, Xue; Dai, Hongxing; Deng, Jiguang; Liu, Yuxi; Zhang, Lei; Zhao, Zhenxuan; Zhang, Ruzhen

    2012-05-30

    Monoclinic BiVO(4) single-crystallites with a polyhedral, spherical or porous octapod-like morphology were selectively prepared using the triblock copolymer P123 (HO(CH(2)CH(2)O)(20)(CH(2)CH(CH(3))O)(70)(CH(2)CH(2)O)(20)H)-assisted hydrothermal method with bismuth nitrate and ammonium metavanadate as metal source and various bases as pH adjustor. The BiVO(4) materials were well characterized and their photocatalytic activities were evaluated for the removal of methylene blue (MB) and phenol in the presence of a small amount of H(2)O(2) under visible-light illumination. It is shown that the pH value of the precursor solution, surfactant, and hydrothermal temperature had an important impact on particle architecture of the BiVO(4) product. The introduction of P123 favored the generation of BiVO(4) with porous structures. The BiVO(4) derived hydrothermally with P123 at pH 3 or 6 possessed good optical absorption performance both in UV- and visible-light regions and hence showed excellent photocatalytic activities for the degradation of MB and phenol. It is concluded that the high visible-light-driven catalytic performance of the porous octapod-like BiVO(4) single-crystallites is associated with the higher surface area, porous structure, lower band gap energy, and unique particle morphology. Such porous BiVO(4) materials are useful in the solar-light-driven photocatalytic treatment of organic-containing wastewater. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. SnO2@C@VO2 Composite Hollow Nanospheres as an Anode Material for Lithium-Ion Batteries.

    PubMed

    Guo, Wenbin; Wang, Yong; Li, Qingyuan; Wang, Dongxia; Zhang, Fanchao; Yang, Yiqing; Yu, Yang

    2018-05-02

    Porous SnO 2 @C@VO 2 composite hollow nanospheres were ingeniously constructed through the combination of layer-by-layer deposition and redox reaction. Moreover, to optimize the electrochemical properties, SnO 2 @C@VO 2 composite hollow nanospheres with different contents of the external VO 2 were also studied. On the one hand, the elastic and conductive carbon as interlayer in the SnO 2 @C@VO 2 composite can not only buffer the huge volume variation during repetitive cycling but also effectively improve electronic conductivity and enhance the utilizing rate of SnO 2 and VO 2 with high theoretical capacity. On the other hand, hollow nanostructures of the composite can be consolidated by the multilayered nanocomponents, resulting in outstanding cyclic stability. In virtue of the above synergetic contribution from individual components, SnO 2 @C@VO 2 composite hollow nanospheres exhibit a large initial discharge capacity (1305.6 mAhg -1 ) and outstanding cyclic stability (765.1 mAhg -1 after 100 cycles). This design of composite hollow nanospheres may be extended to the synthesis of other nanomaterials for electrochemical energy storage.

  3. Naturally formed ultrathin V2O5 heteroepitaxial layer on VO2/sapphire(001) film

    NASA Astrophysics Data System (ADS)

    Littlejohn, Aaron J.; Yang, Yunbo; Lu, Zonghuan; Shin, Eunsung; Pan, KuanChang; Subramanyam, Guru; Vasilyev, Vladimir; Leedy, Kevin; Quach, Tony; Lu, Toh-Ming; Wang, Gwo-Ching

    2017-10-01

    Vanadium dioxide (VO2) and vanadium pentoxide (V2O5) thin films change their properties in response to external stimuli such as photons, temperature, electric field and magnetic field and have applications in electronics, optical devices, and sensors. Due to the multiple valence states of V and non-stoichiometry in thin films, it is challenging to grow epitaxial, single-phase V-oxide on a substrate, or a heterostructure of two epitaxial V-oxides. We report the formation of a heterostructure consisting of a few nm thick ultrathin V2O5 epitaxial layer on pulsed laser deposited tens of nm thick epitaxial VO2 thin films grown on single crystal Al2O3(001) substrates without post annealing of the VO2 film. The simultaneous observation of the ultrathin epitaxial V2O5 layer and VO2 epitaxial film is only possible by our unique reflection high energy electron diffraction pole figure analysis. The out-of-plane and in-plane epitaxial relationships are V2O5[100]||VO2[010]||Al2O3[001] and V2O5[03 2 bar ]||VO2[100]||Al2O3[1 1 bar 0], respectively. The existence of the V2O5 layer on the surface of the VO2 film is also supported by X-ray photoelectron spectroscopy and Raman spectroscopy.

  4. Association of Occupational and Leisure-Time Physical Activity with Aerobic Capacity in a Working Population.

    PubMed

    Mundwiler, Jonas; Schüpbach, Ulla; Dieterle, Thomas; Leuppi, Jörg Daniel; Schmidt-Trucksäss, Arno; Wolfer, David Paul; Miedinger, David; Brighenti-Zogg, Stefanie

    2017-01-01

    Objective data on the association of maximal aerobic capacity (VO2max) with work related physical activity are sparse. Thus, it is not clear whether occupational physical activity (OPA) contributes to an increase of VO2max. This study examined the association of VO2max with work and non-work related physical activity in a Swiss working population. In this cross-sectional study, a total of 337 healthy and full-time employed adults were recruited. Demographic data, height, weight and BMI were recorded in all subjects. Participants were classified into nine occupational categories (ISCO-88) and merged into three groups with low, moderate, and high OPA. Physical activity was objectively measured by the SenseWear Mini Armband on seven consecutive days (23 hours per day). Participants were regarded as sufficiently active when accumulating ≥30 min of moderate-to-vigorous physical activity per day. VO2max was evaluated using the multistage 20-meter shuttle run test. Data of 303 participants were considered for analysis (63% male, age 33 yrs, SD 12). Multiple linear regression analysis (adjusted R2 = 0.69) revealed significant positive associations of VO2max with leisure-time physical activity (LTPA) at vigorous intensity (β = 0.212) and sufficient moderate-to-vigorous physical activity (β = 0.100) on workdays. Female gender (β = -0.622), age (β = -0.264), BMI (β = -0.220), the ratio of maximum to resting heart rate (β = 0.192), occupational group (low vs. high OPA, β = -0.141), and smoking (β = -0.133) were also identified as independent predictors of VO2max. The present results suggest that VO2max is positively associated with LTPA, but not with OPA on workdays. This finding emphasizes the need for employees to engage in sufficient high-intensity physical activity in recreation for maintaining or improving VO2max with regard to health benefits.

  5. Association of Occupational and Leisure-Time Physical Activity with Aerobic Capacity in a Working Population

    PubMed Central

    Mundwiler, Jonas; Schüpbach, Ulla; Dieterle, Thomas; Leuppi, Jörg Daniel; Schmidt-Trucksäss, Arno; Wolfer, David Paul; Miedinger, David; Brighenti-Zogg, Stefanie

    2017-01-01

    Introduction Objective data on the association of maximal aerobic capacity (VO2max) with work related physical activity are sparse. Thus, it is not clear whether occupational physical activity (OPA) contributes to an increase of VO2max. This study examined the association of VO2max with work and non-work related physical activity in a Swiss working population. Methods In this cross-sectional study, a total of 337 healthy and full-time employed adults were recruited. Demographic data, height, weight and BMI were recorded in all subjects. Participants were classified into nine occupational categories (ISCO-88) and merged into three groups with low, moderate, and high OPA. Physical activity was objectively measured by the SenseWear Mini Armband on seven consecutive days (23 hours per day). Participants were regarded as sufficiently active when accumulating ≥30 min of moderate-to-vigorous physical activity per day. VO2max was evaluated using the multistage 20-meter shuttle run test. Results Data of 303 participants were considered for analysis (63% male, age 33 yrs, SD 12). Multiple linear regression analysis (adjusted R2 = 0.69) revealed significant positive associations of VO2max with leisure-time physical activity (LTPA) at vigorous intensity (β = 0.212) and sufficient moderate-to-vigorous physical activity (β = 0.100) on workdays. Female gender (β = -0.622), age (β = -0.264), BMI (β = -0.220), the ratio of maximum to resting heart rate (β = 0.192), occupational group (low vs. high OPA, β = -0.141), and smoking (β = -0.133) were also identified as independent predictors of VO2max. Conclusions The present results suggest that VO2max is positively associated with LTPA, but not with OPA on workdays. This finding emphasizes the need for employees to engage in sufficient high-intensity physical activity in recreation for maintaining or improving VO2max with regard to health benefits. PMID:28045939

  6. Observation of reduced phase transition temperature in N-doped thermochromic film of monoclinic VO2

    NASA Astrophysics Data System (ADS)

    Wan, Meinan; Xiong, Mo; Li, Neng; Liu, Baoshun; Wang, Shuo; Ching, Wai-Yim; Zhao, Xiujian

    2017-07-01

    Research on monoclinic (M1) phase of VO2 has attracted a great of interest for smart coating applications due to its exceptional thermochromic property. Herein, we report the results using a novel approach to synthesize N-doped VO2(M1) thin films with high purity by heat treatment in NH3 atmosphere. The N dopant in the film can be regulated by varying NH3 concentration during the annealing process. We find that the N atoms are located at the interstitial sites or substitute oxygen atoms, and the V-N bonds in the VO2 thin films increase with NH3 concentration. The metal to insulator transition (MIT) temperature (τc,h) of the VO2 thin film is effectively reduced from 80.0 to 62.9 °C, while the solar modulation efficiency (ΔTsol) and the modulation efficiency at 2000 nm (ΔT2000nm) are 7.36% and 55.6% respectively. The band gap of N-doped VO2 thin films related to MIT (Eg1) is estimated to be as low as 0.18-0.25 eV whereas the band gap associated with the visible transparency (Eg2) is about 1.50-1.58 eV. Based on the highly accurate first-principles calculations, the Eg1 of VO2 (M1) is reduced after substituted or interstitial N-doping, while the Eg2 alters with the mode of N-doping, which is excellent agreement with experimental measurement.

  7. Growth of metal oxide nanowires from supercooled liquid nanodroplets.

    PubMed

    Kim, Myung Hwa; Lee, Byeongdu; Lee, Sungsik; Larson, Christopher; Baik, Jeong Min; Yavuz, Cafer T; Seifert, Sönke; Vajda, Stefan; Winans, Randall E; Moskovits, Martin; Stucky, Galen D; Wodtke, Alec M

    2009-12-01

    Nanometer-sized liquid droplets formed at temperatures below the bulk melting point become supercooled as they grow through Ostwald ripening or coalescence and can be exploited to grow nanowires without any catalyst. We used this simple approach to synthesize a number of highly crystalline metal oxide nanowires in a chemical or physical vapor deposition apparatus. Examples of nanowires made in this way include VO(2), V(2)O(5), RuO(2), MoO(2), MoO(3), and Fe(3)O(4), some of which have not been previously reported. Direct evidence of this new mechanism of nanowire growth is found from in situ 2-dimensional GISAXS (grazing incidence small angle X-ray scattering) measurements of VO(2) nanowire growth, which provides quantitative information on the shapes and sizes of growing nanowires as well as direct evidence of the presence of supercooled liquid droplets. We observe dramatic changes in nanowire growth by varying the choice of substrate, reflecting the influence of wetting forces on the supercooled nanodroplet shape and mobility as well as substrate-nanowire lattice matching on the definition of nanowire orientation. Surfaces with defects can also be used to pattern the growth of the nanowires. The simplicity of this synthesis concept suggests it may be rather general in its application.

  8. Vanadium(V) Complexes with Substituted 1,5-bis(2-hydroxybenzaldehyde)carbohydrazones and Their Use As Catalyst Precursors in Oxidation of Cyclohexane.

    PubMed

    Dragancea, Diana; Talmaci, Natalia; Shova, Sergiu; Novitchi, Ghenadie; Darvasiová, Denisa; Rapta, Peter; Breza, Martin; Galanski, Markus; Kožı́šek, Jozef; Martins, Nuno M R; Martins, Luísa M D R S; Pombeiro, Armando J L; Arion, Vladimir B

    2016-09-19

    Six dinuclear vanadium(V) complexes have been synthesized: NH4[(VO2)2((H)LH)] (NH4[1]), NH4[(VO2)2((t-Bu)LH)] (NH4[2]), NH4[(VO2)2((Cl)LH)] (NH4[3]), [(VO2)(VO)((H)LH)(CH3O)] (4), [(VO2)(VO)((t-Bu)LH)(C2H5O)] (5), and [(VO2)(VO)((Cl)LH)(CH3O)(CH3OH/H2O)] (6) (where (H)LH4 = 1,5-bis(2-hydroxybenzaldehyde)carbohydrazone, (t-Bu)LH4 = 1,5-bis(3,5-di-tert-butyl-2-hydroxybenzaldehyde)carbohydrazone, and (Cl)LH4 = 1,5-bis(3,5-dichloro-2-hydroxybenzaldehyde)carbohydrazone). The structures of NH4[1] and 4-6 have been determined by X-ray diffraction (XRD) analysis. In all complexes, the triply deprotonated ligand accommodates two V ions, using two different binding sites ONN and ONO separated by a diazine unit -N-N-. In two pockets of NH4[1], two identical VO2(+) entities are present, whereas, in those of 4-6, two different VO2(+) and VO(3+) are bound. The highest oxidation state of V ions was corroborated by X-ray data, indicating the presence of alkoxido ligand bound to VO(3+) in 4-6, charge density measurements on 4, magnetic susceptibility, NMR spectroscopy, spectroelectrochemistry, and density functional theory (DFT) calculations. All four complexes characterized by XRD form dimeric associates in the solid state, which, however, do not remain intact in solution. Compounds NH4[1], NH4[2], and 4-6 were applied as alternative selective homogeneous catalysts for the industrially significant oxidation of cyclohexane to cyclohexanol and cyclohexanone. The peroxidative (with tert-butyl hydroperoxide, TBHP) oxidation of cyclohexane was performed under solvent-free and additive-free conditions and under low-power microwave (MW) irradiation. Cyclohexanol and cyclohexanone were the only products obtained (high selectivity), after 1.5 h of MW irradiation. Theoretical calculations suggest a key mechanistic role played by the carbohydrazone ligand, which can undergo reduction, instead of the metal itself, to form an active reduced form of the catalyst.

  9. Structure evolution and thermal stability of high-energy density Li-ion battery cathode Li 2VO 2F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xiaoya; Huang, Yiqing; Ji, Dongsheng

    Lithium-ion batteries (LIBs) provide high-energy-density electrochemical energy storage, which plays a central role in advancing technologies ranging from portable electronics to electric vehicles (EVs). However, a demand for lighter, more compact devices and for extended range EVs continues to fuel the need for higher energy density storage systems. Li 2VO 2F, which is synthesized in its lithiated state, allows two-electron transfer per formula during the electrochemical reaction providing a high theoretical capacity of 462 mAh/g. Herein, the synthesis and electrochemical performance of Li 2VO 2F are optimized. The thermal stability of Li 2VO 2F, which is related to the safetymore » of a battery is studied by thermal gravimetric analysis. The structure and vanadium oxidation state evolution along Li cycling are studied by ex-situ X-ray diffraction and absorption techniques. It is shown that the rock-salt structure of pristine Li 2VO 2F is stable up to at least 250°C, and is preserved upon Li cycling, which proceeds by the solid-solution mechanism. However, not all Li can be removed from the structure upon charge to 4.5 V, limiting the experimentally obtained capacity.« less

  10. Structure evolution and thermal stability of high-energy density Li-ion battery cathode Li 2VO 2F

    DOE PAGES

    Wang, Xiaoya; Huang, Yiqing; Ji, Dongsheng; ...

    2017-05-24

    Lithium-ion batteries (LIBs) provide high-energy-density electrochemical energy storage, which plays a central role in advancing technologies ranging from portable electronics to electric vehicles (EVs). However, a demand for lighter, more compact devices and for extended range EVs continues to fuel the need for higher energy density storage systems. Li 2VO 2F, which is synthesized in its lithiated state, allows two-electron transfer per formula during the electrochemical reaction providing a high theoretical capacity of 462 mAh/g. Herein, the synthesis and electrochemical performance of Li 2VO 2F are optimized. The thermal stability of Li 2VO 2F, which is related to the safetymore » of a battery is studied by thermal gravimetric analysis. The structure and vanadium oxidation state evolution along Li cycling are studied by ex-situ X-ray diffraction and absorption techniques. It is shown that the rock-salt structure of pristine Li 2VO 2F is stable up to at least 250°C, and is preserved upon Li cycling, which proceeds by the solid-solution mechanism. However, not all Li can be removed from the structure upon charge to 4.5 V, limiting the experimentally obtained capacity.« less

  11. Physiological response to the 6-minute walk test in chronic heart failure patients versus healthy control subjects.

    PubMed

    Deboeck, Gaël; Van Muylem, Alain; Vachiéry, Jean Luc; Naeije, Robert

    2014-08-01

    The distance walked in 6 minutes (6MWD) has been reported to be linearly related to peak oxygen uptake (VO2) in cardiac diseases and in lung diseases. In these patients, the VO2 during a 6-min walk test (walkVO2) has been found to be nearly equivalent to peakVO2, but with a lower respiratory exchange ratio (RER). Whether these observations translate to the less functionally impaired patients or healthy control subjects is not exactly known. Thirty-two healthy control subjects and 15 chronic heart failure (CHF) patients performed a 6-min walk test and a maximal cardiopulmonary exercise test (CPET) both with measurements of gas exchange. The 6MWD and peakVO2 were linearly correlated, but with an increased slope appearing above 532 m. In CHF patients, walkVO2 was similar to peakVO2, but with lower heart rate and ventilation than measured at peak exercise. In healthy control subjects, VO2, ventilation and heart rate were lower during the 6-min walk than at maximal exercise but higher than at the anaerobic threshold. The RER during the 6-min walk remained <1 in both groups. Above 500 m, 6MWD becomes less sensitive to any increase in peakVO2. Furthermore, CHF patients and healthy control subjects exercise respectively at maximal and high VO2, but below the anaerobic threshold (as assessed by a CPET) during the 6-min walk test. © The European Society of Cardiology 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. Localized phase change of VO2 films grown by atomic-layer deposition on InAlN/AlN/GaN heterostructures

    NASA Astrophysics Data System (ADS)

    Downey, Brian P.; Wheeler, Virginia D.; Meyer, David J.

    2017-06-01

    We demonstrate the thermally actuated phase change of VO2 films formed by atomic layer deposition and subsequent thermal annealing on InAlN/AlN/GaN heterostructures. To locally raise the device temperature above the VO2 semiconductor-metal transition temperature, a two-dimensional electron gas formed within the InAlN/AlN/GaN heterostructure was used as an integrated resistive heater. An ON/OFF resistance ratio of nearly 103 was achieved for 50 nm VO2 films over a temperature range of 25 to 105 °C. The time required to switch the VO2 film from high- to low-resistance states was shown to depend on the applied heater power, with sub-microsecond transition times achieved.

  13. Fabrication of bristlegrass-like VO2 (B)-ZnO heteroarchitectures as anode materials for lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Ma, Yining; Li, Wenjing; Ji, Shidong; Zhou, Huaijuan; Li, Rong; Li, Ning; Yao, Heliang; Cao, Xun; Jin, Ping

    2017-08-01

    Three-dimensional bristlegrass-like hierarchical VO2 (B)-ZnO heteroarchitectures with ZnO nanorods grown radially on VO2 (B) nanorods were successfully fabricated via a simple two-step synthesized method. When applied as an anode material for lithium-ion batteries, the VO2 (B)-ZnO hybrid electrode exhibited high reversible capacity and excellent recyclability, which could be originated from the unique hierarchical structure of the bristlegrass. After 80 cycles, the nanocomposite still maintained a higher reversible capacity of 329.4 mA h g-1 at a current density of 50 mA g-1. Therefore, the particular architecture of VO2 (B)-ZnO nanocomposite can be a promising candidate as the anode material in lithium-ion batteries.

  14. Sex-specific responses to self-paced, high-intensity interval training with variable recovery periods.

    PubMed

    Laurent, C Matthew; Vervaecke, Lauren S; Kutz, Matthew R; Green, J Matthew

    2014-04-01

    This study examined sex-specific responses during self-paced, high-intensity interval training (HIIT). Sixteen (8 men and 8 women) individuals completed a peak oxygen uptake test and 3 treadmill HIIT sessions on separate days. The HIIT sessions consisted of six 4-minute intervals performed at the highest self-selected intensity individuals felt they could maintain. Recovery between intervals was counterbalanced and consisted of 1-, 2-, or 4-minute recovery during each trial. Relative measures of intensity, including percentage of velocity at VO2peak (vVO2peak), %VO2peak, %HRmax, and blood lactate concentration ([La]), were observed during the trials. Perceived readiness was recorded immediately before and ratings of perceived exertion (RPE) were recorded at the end of each interval with session RPE recorded after each trial. Results revealed a significant effect of sex on %vVO2peak (p < 0.01) and %HRmax (p < 0.01). Data show that across trials, men self-select higher %vVO2peak (84.5 vs. 80.7%), whereas women produce higher %HRmax (96.9 vs. 92.1%) and %VO2peak (89.6 vs. 86.1%) with no difference in [La] or perceptual responses. These findings support the notion that women may demonstrate improved recovery during high-intensity exercise, as they will self-select intensities resulting in greater cardiovascular strain. Moreover, results confirm previous findings suggesting that a 2:1 work-to-rest ratio is optimal during HIIT for both men and women.

  15. Familial aggregation of VO(2max) response to exercise training: results from the HERITAGE Family Study.

    PubMed

    Bouchard, C; An, P; Rice, T; Skinner, J S; Wilmore, J H; Gagnon, J; Pérusse, L; Leon, A S; Rao, D C

    1999-09-01

    The aim of this study was to test the hypothesis that individual differences in the response of maximal O(2) uptake (VO(2max)) to a standardized training program are characterized by familial aggregation. A total of 481 sedentary adult Caucasians from 98 two-generation families was exercise trained for 20 wk and was tested for VO(2max) on a cycle ergometer twice before and twice after the training program. The mean increase in VO(2max) reached approximately 400 ml/min, but there was considerable heterogeneity in responsiveness, with some individuals experiencing little or no gain, whereas others gained >1.0 l/min. An ANOVA revealed that there was 2.5 times more variance between families than within families in the VO(2max) response variance. With the use of a model-fitting procedure, the most parsimonious models yielded a maximal heritability estimate of 47% for the VO(2max) response, which was adjusted for age and sex with a maternal transmission of 28% in one of the models. We conclude that the trainability of VO(2max) is highly familial and includes a significant genetic component.

  16. Comparison of Methods for Determining Aerobic Exercise Intensity Using Heart Rate in Acute Leukemia Patients Prior to Induction Chemotherapy

    PubMed Central

    Story, Christina; Bryant, Ashley Leak; Phillips, Brett; Bailey, Charlotte; Shields, Edgar W.; Battaglini, Claudio

    2018-01-01

    Introduction Cardiopulmonary exercise testing (CPET), the gold standard of cardiopulmonary evaluation, is used to determine VO2 levels at different aerobic exercise training intensities; however, it may not be feasible to conduct CPET in all clinical settings. Aims To compare the heart rate reserve (HRR) and percent of 220-age methods for prescribing cycle ergometry exercise intensity using heart rate (HR) against the HRs obtained during a CPET in adults undergoing treatment for acute leukemia (AL). Methods In this exploratory study, part of a larger randomized controlled trial, 14 adults with AL completed CPET on a cycle ergometer with indirect calorimetry within 96 hr of admission to a cancer hospital to determine VO2peak and HR corresponding to low (40% VO2peak), moderate (60% VO2peak), and high (75% VO2peak) exercise intensities. Analyses of variance were used to compare estimated HR for each intensity level using the HRR and percent of 220-age methods with HR determined via VO2peak. Results HR corresponding to low-intensity exercise differed significantly across all three methods (p ≤ .05). No significant differences were observed between HR estimated via the percent of 220-age method and determined via VO2peak at moderate (100 ± 8 and 113 ± 24 bpm, p = .122) or high intensities (125 ± 10 and 123 ± 25 bpm, p = .994). Conclusion In adults with AL, HR-based methods for defining aerobic exercise intensities should be used with caution. At low intensity, neither should be used, while at moderate and high intensities, the percent of 220-age equation might serve as an adequate substitute for CPET. PMID:26933148

  17. Dual-cycle ergometry as an exercise modality during prebreathe with 100 percent oxygen

    NASA Technical Reports Server (NTRS)

    Heaps, Cristine L.; Fischer, Michele D.; Webb, James T.

    1994-01-01

    In an effort to reduce prebreathe time requirements prior to extravehicular activities and high-altitude flights, a combined arm and leg exercise task proposes to enhance denitrogenation by incorporation of both upper and lower body musculature at a moderately high work intensity during prebreathe with 100% oxygen. Preliminary findings indicated peak oxygen consumption (VO2peak) levels attained on the dual-cycle ergometer do not differ significantly from those levels attained on the treadmill. Eight male subjects were exercised to VO2peak using leg-only cycle ergometry and dual-cycle ergometry on separate days. Preliminary data during dual-cycle ergometry showed arm work equaling 30% of the leg workrate at each stage of the incremental test resulted in arm fatigue in several subjects and a reduced VO2peak compared to dual-cycle ergometry with arm work at 20%. Thus, the 20% workrate was used during the dual-cycle VO2peak trial. On a third experimental day, subjects performed a 10 minute exercise test at a workrate required to elicit 75% of VO2peak for each subject on the dual-cycle ergometer. Blood lactate response to the exercise was monitored as an objective measure of fatigue. Peak VO2 levels attained on the leg-only and the dual-cycle ergometry tasks were not significantly different. Blood lactate levels were significantly elevated following the dual-cycle ergometry at 75% VO2peak. However, lactate levels show the expected rate of decline during recovery and, as demonstrated in the literature, should return to baseline levels within 30 minutes following exercise cessation. Thus, dual-cycle ergometry at 75% VO2peak appears to be a valid exercise for use during prebreathe and should not contribute to fatigue during subsequent EVA's.

  18. VO2 nanorods for efficient performance in thermal fluids and sensors

    NASA Astrophysics Data System (ADS)

    Dey, Kajal Kumar; Bhatnagar, Divyanshu; Srivastava, Avanish Kumar; Wan, Meher; Singh, Satyendra; Yadav, Raja Ram; Yadav, Bal Chandra; Deepa, Melepurath

    2015-03-01

    VO2 (B) nanorods with average width ranging between 50-100 nm are synthesized via a hydrothermal method and the post hydrothermal treatment drying temperature is found to be influential in their overall phase and growth morphology evolution. The nanorods with unusually high optical bandgap for a VO2 material are effective in enhancing the thermal performance of ethylene glycol nanofluids over a wide temperature range as is indicated by the temperature dependent thermal conductivity measurements. Humidity and LPG sensors fabricated using the VO2 (B) nanorods bear testament to their efficient sensing performance, which can be partially attributed to the mesoporous nature of the nanorods.VO2 (B) nanorods with average width ranging between 50-100 nm are synthesized via a hydrothermal method and the post hydrothermal treatment drying temperature is found to be influential in their overall phase and growth morphology evolution. The nanorods with unusually high optical bandgap for a VO2 material are effective in enhancing the thermal performance of ethylene glycol nanofluids over a wide temperature range as is indicated by the temperature dependent thermal conductivity measurements. Humidity and LPG sensors fabricated using the VO2 (B) nanorods bear testament to their efficient sensing performance, which can be partially attributed to the mesoporous nature of the nanorods. Electronic supplementary information (ESI) available: Plots representing the actual ratio Knf/KEG (Knf is the thermal conductivity of the nanofluid and KEG being thermal conductivity of the base fluid) across the entire experimental temperature range of 20 to 80 °C, table representing a comparison of performance of the VO2 sensor towards different gases. See DOI: 10.1039/c4nr06032f

  19. Exercise intensities during a ballet lesson in female adolescents with different technical ability.

    PubMed

    Guidetti, L; Gallotta, M C; Emerenziani, G P; Baldari, C

    2007-09-01

    To investigate the exercise intensity during a typical grade five ballet lesson, thirty-nine dancers (13 - 16 yrs) were divided into three different technical proficiency groups: low level (n = 13), intermediate level (n = 14), and high level (n = 12). A progressively incremented treadmill test was administered to determine VO(2max), individual ventilatory threshold (IVT), and the individual anaerobic threshold (IAT). Oxygen uptake (VO(2)), heart rate (HR) and blood lactate (La) were then evaluated during a grade five ballet lesson. Oxygen uptake at IVT, IAT and maximal oxygen uptake were greater (p < 0.05) in the high-level dancers indicating a higher level of fitness. HR and %VO(2max) obtained during the various exercises of the ballet lesson were similar among groups. During the ballet lesson, low technical level dancers had more V.O (2) and La values above (p < 0.05) the IAT than the other groups. Correlation analysis revealed that the number of exercises performed above IAT was positively related to anthropometric characteristics (BMI, %FM; r = 0.36, p < 0.05; r = 0.46, p < 0.01), negatively related to fitness parameters (VO(2IVT), VO(2IAT), VO(2max); r between - 0.43 and - 0.69; p < 0.001) and to technical level (r = - 0.70; p < 0.001). The subjects classified as having low technical abilities had lower fitness levels and performed more exercises above IAT than the more skilled dancers.

  20. Electrochemically Induced Insulator-Metal-Insulator Transformations of Vanadium Dioxide Nanocrystal Films

    NASA Astrophysics Data System (ADS)

    Milliron, Delia; Dahlman, Clayton; Leblanc, Gabriel; Bergerud, Amy

    Vanadium dioxide (VO2) undergoes significant optical, electronic, and structural changes as it transforms between the low-temperature monoclinic and high-temperature rutile phases. The low-temperature state is insulating and transparent, while the high-temperature state is metallic and IR blocking. Alternative stimuli have been utilized to trigger insulator-to-metal transformations in VO2, including electrochemical gating. Here, VO2 nanocrystal films have been prepared by solution deposition of V2O3 nanocrystals followed by oxidative annealing. Nanocrystalline VO2 films are electrochemically reduced, inducing changes in their electronic and optical properties. We observe a reversible transition between infrared transparent insulating phases and a darkened metallic phase by in situ visible-near-infrared spectroelectrochemistry and correlate these observations with structural and electronic changes monitored by X-ray absorption spectroscopy, X-ray diffraction, Raman spectroscopy, and conductivity measurements. Reduction causes an initial transformation to a metallic, IR-colored distorted monoclinic phase. However, an unexpected reversible transition from conductive, reduced monoclinic VO2 to an infrared-transparent insulating phase is observed upon further reduction.

  1. Heart rate during basketball game play and volleyball drills accurately predicts oxygen uptake and energy expenditure.

    PubMed

    Scribbans, T D; Berg, K; Narazaki, K; Janssen, I; Gurd, B J

    2015-09-01

    There is currently little information regarding the ability of metabolic prediction equations to accurately predict oxygen uptake and exercise intensity from heart rate (HR) during intermittent sport. The purpose of the present study was to develop and, cross-validate equations appropriate for accurately predicting oxygen cost (VO2) and energy expenditure from HR during intermittent sport participation. Eleven healthy adult males (19.9±1.1yrs) were recruited to establish the relationship between %VO2peak and %HRmax during low-intensity steady state endurance (END), moderate-intensity interval (MOD) and high intensity-interval exercise (HI), as performed on a cycle ergometer. Three equations (END, MOD, and HI) for predicting %VO2peak based on %HRmax were developed. HR and VO2 were directly measured during basketball games (6 male, 20.8±1.0 yrs; 6 female, 20.0±1.3yrs) and volleyball drills (12 female; 20.8±1.0yrs). Comparisons were made between measured and predicted VO2 and energy expenditure using the 3 equations developed and 2 previously published equations. The END and MOD equations accurately predicted VO2 and energy expenditure, while the HI equation underestimated, and the previously published equations systematically overestimated VO2 and energy expenditure. Intermittent sport VO2 and energy expenditure can be accurately predicted from heart rate data using either the END (%VO2peak=%HRmax x 1.008-17.17) or MOD (%VO2peak=%HRmax x 1.2-32) equations. These 2 simple equations provide an accessible and cost-effective method for accurate estimation of exercise intensity and energy expenditure during intermittent sport.

  2. Size and composition-controlled fabrication of VO2 nanocrystals by terminated cluster growth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anders, Andre; Slack, Jonathan

    2013-05-14

    A physical vapor deposition-based route for the fabrication of VO2 nanoparticles is demonstrated, consisting of reactive sputtering and vapor condensation at elevated pressures. The oxidation of vanadium atoms is an efficient heterogeneous nucleation method, leading to high nanoparticle throughtput. Fine control of the nanoparticle size and composition is obtained. Post growth annealing leads to crystalline VO2 nanoparticles with optimum thermocromic and plasmonic properties.

  3. Oscillation of tissue oxygen index in non-exercising muscle during exercise.

    PubMed

    Yano, T; Afroundeh, R; Shirakawa, K; Lian, C-S; Shibata, K; Xiao, Z; Yunoki, T

    2015-09-01

    The purpose of the present study was to examine how oscillation of tissue oxygen index (TOI) in non-exercising exercise is affected during high-intensity and low-intensity exercises. Three exercises were performed with exercise intensities of 30% and 70% peak oxygen uptake (Vo(2)peak) for 12 min and with exercise intensity of 70% Vo(2)peak for 30 s. TOI in non-exercising muscle (biceps brachii) during the exercises for 12 min was determined by nearinfrared spectroscopy. TOI in the non-exercising muscle during the exercises was analyzed by fast Fourier transform (FFT) to obtain power spectra density (PSD). The frequency at which maximal PSD appeared (Fmax) during the exercise with 70% Vo(2)peak for 12 min (0.00477 ± 0.00172 Hz) was significantly lower than that during the exercise with 30% Vo2peak for 12 min (0.00781 ± 0.00338 Hz). There were significant differences in blood pH and blood lactate between the exercise with 70% Vo(2)peak and the exercise with 30% Vo(2)peak. It is concluded that TOI in nonexercising muscle oscillates during low-intensity exercise as well as during high-intensity exercise and that the difference in Fmax between the two exercises is associated with the difference in increase in blood lactate derived from the exercise.

  4. Effect of 24 sessions of high-intensity aerobic interval training carried out at either high or moderate frequency, a randomized trial.

    PubMed

    Hatle, Håvard; Støbakk, Per Kristian; Mølmen, Harald Edvard; Brønstad, Eivind; Tjønna, Arnt Erik; Steinshamn, Sigurd; Skogvoll, Eirik; Wisløff, Ulrik; Ingul, Charlotte Björk; Rognmo, Øivind

    2014-01-01

    The training response of an intensified period of high-intensity exercise is not clear. Therefore, we compared the cardiovascular adaptations of completing 24 high-intensity aerobic interval training sessions carried out for either three or eight weeks, respectively. Twenty-one healthy subjects (23.0±2.1 years, 10 females) completed 24 high-intensity training sessions throughout a time-period of either eight weeks (moderate frequency, MF) or three weeks (high frequency, HF) followed by a detraining period of nine weeks without any training. In both groups, maximal oxygen uptake (VO2max) was evaluated before training, at the 9(th) and 17(th) session and four days after the final 24(th) training session. In the detraining phase VO2max was evaluated after 12 days and thereafter every second week for eight weeks. Left ventricular echocardiography, carbon monoxide lung diffusion transfer factor, brachial artery flow mediated dilatation and vastus lateralis citrate maximal synthase activity was tested before and after training. The cardiovascular adaptation after HF training was delayed compared to training with MF. Four days after ending training the HF group showed no improvement (+3.0%, p = 0.126), whereas the MF group reached their highest VO2max with a 10.7% improvement (p<0.001: group difference p = 0.035). The HF group reached their highest VO2max (6.1% increase, p = 0.026) twelve days into the detraining period, compared to a concomitant reduction to 7.9% of VO2max (p<0.001) above baseline in the MF group (group difference p = 0.609). Both HF and MF training of high-intensity aerobic exercise improves VO2max. The cardiovascular adaptation following a HF programme of high-intensity exercise is however delayed compared to MF training. ClinicalTrials.gov NCT00733941.

  5. Spanish genetic admixture is associated with larger V(O2) max decrement from sea level to 4338 m in Peruvian Quechua.

    PubMed

    Brutsaert, Tom D; Parra, Esteban J; Shriver, Mark D; Gamboa, Alfredo; Palacios, Jose-Antonio; Rivera, Maria; Rodriguez, Ivette; León-Velarde, Fabiola

    2003-08-01

    Quechua in the Andes may be genetically adapted to altitude and able to resist decrements in maximal O2 consumption in hypoxia (DeltaVo2 max). This hypothesis was tested via repeated measures of Vo2 max (sea level vs. 4338 m) in 30 men of mixed Spanish and Quechua origins. Individual genetic admixture level (%Spanish ancestry) was estimated by using ancestry-informative DNA markers. Genetic admixture explained a significant proportion of the variability in DeltaVo2 max after control for covariate effects, including sea level Vo2 max and the decrement in arterial O2 saturation measured at Vo2 max (DeltaSpO2 max) (R2 for admixture and covariate effects approximately 0.80). The genetic effect reflected a main effect of admixture on DeltaVo2 max (P = 0.041) and an interaction between admixture and DeltaSpO2 max (P = 0.018). Admixture predicted DeltaVo2 max only in subjects with a large DeltaSpO2 max (P = 0.031). In such subjects, DeltaVo2 max was 12-18% larger in a subgroup of subjects with high vs. low Spanish ancestry, with least squares mean values (+/-SE) of 739 +/- 71 vs. 606 +/- 68 ml/min, respectively. A trend for interaction (P = 0.095) was also noted between admixture and the decrease in ventilatory threshold at 4338 m. As previously, admixture predicted DeltaVo2 max only in subjects with a large decrease in ventilatory threshold. These findings suggest that the genetic effect on DeltaVo2 max depends on a subject's aerobic fitness. Genetic effects may be more important (or easier to detect) in athletic subjects who are more likely to show gas-exchange impairment during exercise. The results of this study are consistent with the evolutionary hypothesis and point to a better gas-exchange system in Quechua.

  6. Microwave-assisted in situ synthesis of reduced graphene oxide-BiVO4 composite photocatalysts and their enhanced photocatalytic performance for the degradation of ciprofloxacin.

    PubMed

    Yan, Yan; Sun, Shaofang; Song, Yang; Yan, Xu; Guan, Weisheng; Liu, Xinlin; Shi, Weidong

    2013-04-15

    To improve the photodegradation efficiency for ciprofloxacin (CIP), a new-type microwave-assisted in situ growth method is developed for the preparation of reduced graphene oxide (RGO) -BiVO4 composite photocatalysts. The as-produced RGO-BiVO4 composite photocatalysts show extremely high enhancement of CIP degradation ratio over the pure BiVO4 photocatalyst under visible light. Specially, the 2 wt% RGO-BiVO4 composite photocatalyst exhibits the highest CIP degradation ratio (68.2%) in 60 min, which is over 3 times than that (22.7%) of the pure BiVO4 particles. The enhancement of photocatalytic activities of RGO-BiVO4 photocatalysts can be attributed to the effective separation of electron-hole pairs rather than the improvement of light absorption. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Controlled synthesis of Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites with enhanced visible-light photocatalytic performance for the degradation of RhB and 2, 4-DCP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Xuemei; School of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090; Gu, Miaoli

    Highlights: • Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites were synthesized by in-situ precipitation method. • Ag{sub 3}PO{sub 4}/BiVO{sub 4} is more efficient than pure Ag{sub 3}PO{sub 4} and BiVO{sub 4} for RhB and 2, 4-DCP degradation. • Ag{sub 3}PO{sub 4}/BiVO{sub 4} can act as a high performance and low cost photocatalyst. - Abstract: Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites were fabricated by in-situ precipitation method. Results showed that Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites exhibited higher photocatalytic activity than that of pure BiVO{sub 4} and Ag{sub 3}PO{sub 4} sample under visible light irradiation. The effect of Ag{sub 3}PO{sub 4}:BiVO{sub 4} ratio on themore » photocatalytic activity was systemically studied and the optimum molar ratio of Ag{sub 3}PO{sub 4}:BiVO{sub 4} was 1:5. The Ag{sub 3}PO{sub 4}/BiVO{sub 4}-5 exhibited excellent photocatalytic activity for the degradation of Rhodamine B (ca. 92% in 30 min) and 2, 4-dichlorophenol (ca. 84% in 180 min) under visible light irradiation. The enhanced photocatalytic activity could be mainly ascribed to the suitable Ag{sub 3}PO{sub 4}/BiVO{sub 4} heterojunction interface and the smaller particles of Ag{sub 3}PO{sub 4} compared to pure Ag{sub 3}PO{sub 4} particles which could promote the separation of photoinduced electron-hole pairs. The Ag{sub 3}PO{sub 4}/BiVO{sub 4} composite can significantly reduce the silver consumption compared to the pure Ag{sub 3}PO{sub 4}. It is worth noting that Ag{sub 3}PO{sub 4}/BiVO{sub 4} composite can act as a high performance and low cost visible-light-driven photocatalyst for environmental remediation.« less

  8. Running economy : the forgotten factor in elite performance.

    PubMed

    Foster, Carl; Lucia, Alejandro

    2007-01-01

    Running performance depends on maximal oxygen uptake (VO(2max)), the ability to sustain a high percentage of VO(2max) for an extended period of time and running economy. Running economy has been studied relatively less than the other factors. Running economy, measured as steady state oxygen uptake (VO(2)) at intensities below the ventilatory threshold is the standard method. Extrapolation to a common running speed (268 m/min) or as the VO(2) required to run a kilometer is the standard method of assessment. Individuals of East African origin may be systematically more economical, although a smaller body size and a thinner lower leg may be the primary factors. Strategies for improving running economy remain to be developed, although it appears that high intensity running may be a common element acting to improve economy.

  9. Inverse relationship between VO2max and economy/efficiency in world-class cyclists.

    PubMed

    Lucía, Alejandro; Hoyos, Jesus; Pérez, Margarita; Santalla, Alfredo; Chicharro, José L

    2002-12-01

    To determine the relationship that exists between VO2max and cycling economy/efficiency during intense, submaximal exercise in world-class road professional cyclists. METHODS Each of 11 male cyclists (26+/-1 yr (mean +/- SEM); VO2max: 72.0 +/- 1.8 mL x kg(-1) x min(-1)) performed: 1) a ramp test for O2max determination and 2) a constant-load test of 20-min duration at the power output eliciting 80% of subjects' VO2max during the previous ramp test (mean power output of 385 +/- 7 W). Cycling economy (CE) and gross mechanical efficiency (GE) were calculated during the constant-load tests. CE and GE averaged 85.2 +/- 2.3 W x L(-1) x min(-1) and 24.5 +/- 0.7%, respectively. An inverse, significant correlation was found between 1) VO2max (mL x kg(-0.32) x min(-1)) and both CE (r = -0.71; P = 0.01) and GE (-0.72; P = 0.01), and 2) VO2max (mL x kg(-1) x min(-1)) and both CE (r = -0.65; P = 0.03) and GE (-0.64; P = 0.03). A high CE/GE seems to compensate for a relatively low VO2max in professional cyclists.

  10. Sex-Related Differences in Self-Paced All Out High-Intensity Intermittent Cycling: Mechanical and Physiological Responses

    PubMed Central

    Panissa, Valéria L. G.; Julio, Ursula F.; França, Vanessa; Lira, Fabio S.; Hofmann, Peter; Takito, Monica Y.; Franchini, Emerson

    2016-01-01

    The purpose of this study was to compare sex-related responses to a self-paced all out high-intensity intermittent exercise (HIIE). 9 women and 10 men were submitted to a maximal incremental test (to determine maximum aerobic power - MAP and VO2peak), and an HIIE cycling (60x8s:12s, effort:pause). During the protocol the mean value of V̇O2 and heart rate for the entire exercise (VO2total and HRtotal) as well as the values only in the effort or pause (V̇O2effort, VO2pause and HReffort and HRpause) relative to VO2peak were measured. Anaerobic power reserve (APR), blood lactate [La] and the respiratory exchange ratio (RER) were also measured. These variables were compared between men and women using the unpaired t test. Men used greater APR (109 ± 12%MAP vs 92 ± 6%MAP) with similar V̇O2total (74 ± 7 vs 78 ± 8% VO2peak), however, when effort and pause were analysed separately, V̇O2effort (80 ± 9 vs 80 ± 5%VO2peak) was similar between sexes, while V̇O2pause was lower in men (69 ± 6% vs 77 ± 11% VO2peak, respectively). Women presented lower power decrement (30 ± 11 vs 11 ± 3%), RER (1.04 ± 0.03 vs 1.00 ± 0.02) and [La]peak (8.6 ± 0.9 vs 5.9 ± 2.3 mmol.L-1). Thus, we can conclude that men self-paced HIIE at higher APR but with the same cardiovascular/aerobic solicitation as women. Key points Men self-paced high-intensity intermittent exercise at higher intensities than women. Men utilized greater anaerobic power reserve than women. Men and women had same cardiovascular solicitation. PMID:27274678

  11. Development and evaluation of novel flavour microcapsules containing vanilla oil using complex coacervation approach.

    PubMed

    Yang, Ziming; Peng, Zheng; Li, Jihua; Li, Sidong; Kong, Lingxue; Li, Puwang; Wang, Qinghuang

    2014-02-15

    A novel flavour microcapsule containing vanilla oil (VO) was developed using complex coacervation approach, aimed to control release of VO and enhance its thermostability for spice application in food industry. Viscosity of chitosan (CS) and VO/CS ratio were optimised for fabrication of microcapsules. The flavour microcapsules were evaluated by scanning electron micrograph (SEM), laser confocal microscopy (LSCM), particle size analyser, infrared spectrometer (FT-IR), thermal analysis and controlled-release analysis. The microcapsules were in spherical with good dispersibility when moderate viscosity CS was used. 94.2% of encapsulation efficiency was achieved in VO/CS ratio of 2:1. The FT-IR study proved chemical cross-linking reaction occurred between genipin and chitosan, but a physical interaction between CS and VO. A core-shell structure of microcapsule was confirmed by LSCM, which was beneficial to improve the thermostability of VO in microcapsule. Moreover, VO could be remained about 60% in the microcapsules after release for 30 days, which demonstrated the flavour microcapsules had good potential to serve as a high quality food spice with long residual action and high thermostability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Synthesis of Bi2S3/BiVO4 Heterojunction with a One-Step Hydrothermal Method Based on pH Control and the Evaluation of Visible-Light Photocatalytic Performance

    PubMed Central

    Zhao, Deqiang; Wang, Wenwen; Zong, Wenjuan; Xiong, Shimin; Zhang, Qian; Ji, Fangying; Xu, Xuan

    2017-01-01

    The band gaps of bismuth vanadate (BiVO4) and bismuth sulfide (Bi2S3) are about 2.40 eV and 1.30 eV, respectively. Although both BiVO4 and Bi2S3 are capable of strong visible light absorption, electron–hole recombination occurs easily. To solve this problem, we designed a one-step hydrothermal method for synthesizing a Bismuth sulfide (Bi2S3)/Bismuth vanadate (BiVO4) heterojunction using polyvinylpyrrolidone K-30 (PVP) as a structure-directing agent, and 2-Amino-3-mercaptopropanoic acid (l-cysteine) as a sulfur source. The pH of the reaction solution was regulated to yield different products: when the pH was 7.5, only monoclinic BiVO4 was produced (sample 7.5); when the pH was 8.0 or 8.5, both Bi2S3 and BiVO4 were produced (samples 8.0 and 8.5); and when the pH was 9.0, only Bi2S3 was produced (sample 9.0). In sample 8.0, Bi2S3 and BiVO4 were closely integrated with each other, with Bi2S3 particles formed on the surface of concentric BiVO4 layers, but the two compounds grew separately in a pH solution of 8.5. Visible-light photocatalytic degradation experiments demonstrated that the degradation efficiency of the Bi2S3/BiVO4 heterojunction was highest when prepared under a pH of 8.0. The initial rhodamine B in the solution (5 mg/L) was completely degraded within three hours. Recycling experiments verified the high stability of Bi2S3/BiVO4. The synthesis method proposed in this paper is expected to enable large-scale and practical use of Bi2S3/BiVO4. PMID:28767085

  13. Microwave assisted growth of nanorods vanadium dioxide VO2 (R): structural and electrical properties

    NASA Astrophysics Data System (ADS)

    Derkaoui, I.; Khenfouch, M.; Mothudi, B. M.; Moloi, S. J.; Zorkani, I.; Jorio, A.; Maaza, M.

    2018-03-01

    Nanostructured metal oxides have attracted a lot of attention recently owning to their unique structural advantages and demonstrated promising chemical and physical properties for various applications. In this study, we report the structural and electrical properties of vanadium dioxide VO2 (R) prepared via a single reaction microwave (SRC) synthesis. Our results are revealing that the components of VO2 (R) films have a rod-like shape with a uniform size distribution. The nanorods with very smooth and flat surfaces have a typical length of up to 2μm and a width of about several nanometers. The structural investigations reveal the high crystallinity of VO2 (R) ensuring good electrical contact and showing a high conductivity as a function of temperature. This synthesis method provides a new simple route to fabricate one-dimensional nanostructured metal oxides which is suitable for a large field of applications especially for smart windows.

  14. Growth temperature-dependent metal–insulator transition of vanadium dioxide epitaxial films on perovskite strontium titanate (111) single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Liangxin; Zhao, Jiangtao; Hong, Bin

    2016-04-14

    Vanadium dioxide (VO{sub 2}) epitaxial films were grown on perovskite single-crystal strontium titanate (SrTiO{sub 3}) substrates by reactive radio-frequency magnetron sputtering. The growth temperature-dependent metal–insulator transition (MIT) behavior of the VO{sub 2} epitaxial films was then investigated. We found that the order of magnitude of resistance change across the MIT increased from 10{sup 2} to 10{sup 4} with increasing growth temperature. In contrast, the temperature of the MIT does not strongly depend on the growth temperature and is fairly stable at about 345 K. On one hand, the increasing magnitude of the MIT is attributed to the better crystallinity and thusmore » larger grain size in the (010)-VO{sub 2}/(111)-SrTiO{sub 3} epitaxial films at elevated temperature. On the other hand, the strain states do not change in the VO{sub 2} films deposited at various temperatures, resulting in stable V-V chains and V-O bonds in the VO{sub 2} epitaxial films. The accompanied orbital occupancy near the Fermi level is also constant and thus the MIT temperatures of VO{sub 2} films deposited at various temperatures are nearly the same. This work demonstrates that high-quality VO{sub 2} can be grown on perovskite substrates, showing potential for integration into oxide heterostructures and superlattices.« less

  15. Verification testing to confirm VO2max attainment in persons with spinal cord injury.

    PubMed

    Astorino, Todd A; Bediamol, Noelle; Cotoia, Sarah; Ines, Kenneth; Koeu, Nicolas; Menard, Natasha; Nyugen, Brianna; Olivo, Cassandra; Phillips, Gabrielle; Tirados, Ardreen; Cruz, Gabriela Velasco

    2018-01-22

    Maximal oxygen uptake (VO 2 max) is a widely used measure of cardiorespiratory fitness, aerobic function, and overall health risk. Although VO 2 max has been measured for almost 100 yr, no standardized criteria exist to verify VO 2 max attainment. Studies document that incidence of 'true' VO 2 max obtained from incremental exercise (INC) can be confirmed using a subsequent verification test (VER). In this study, we examined efficacy of VER in persons with spinal cord injury (SCI). Repeated measures, within-subjects study. University laboratory in San Diego, CA. Ten individuals (age and injury duration = 33.3 ± 10.5 yr and 6.8 ± 6.2 yr) with SCI and 10 able-bodied (AB) individuals (age = 24.1 ± 7.4 yr). Peak oxygen uptake (VO 2 peak) was determined during INC on an arm ergometer followed by VER at 105 percent of peak power output (% PPO). Gas exchange data, heart rate (HR), and blood lactate concentration (BLa) were measured during exercise. Across all participants, VO 2 peak was highly related between protocols (ICC = 0.98) and the mean difference was equal to 0.08 ± 0.11 L/min. Compared to INC, VO 2 peak from VER was not different in SCI (1.30 ± 0.45 L/min vs. 1.31 ± 0.43 L/min) but higher in AB (1.63 ± 0.40 L/min vs. 1.76 ± 0.40 L/min). Data show similar VO 2 peak between incremental and verification tests in SCI, suggesting that VER confirms VO 2 max attainment. However, in AB participants completing arm ergometry, VER is essential to validate appearance of 'true' VO 2 peak.

  16. Muscle glycogen reduction in man: relationship between surface EMG activity and oxygen uptake kinetics during heavy exercise.

    PubMed

    Osborne, Mark A; Schneider, Donald A

    2006-01-01

    The purpose of this study was to determine whether muscle glycogen reduction prior to exercise would alter muscle fibre recruitment pattern and change either on-transient O2 uptake (VO2) kinetics or the VO2 slow component. Eight recreational cyclists (VO2peak, 55.6 +/- 1.3 ml kg (-1) min(-1)) were studied during 8 min of heavy constant-load cycling performed under control conditions (CON) and under conditions of reduced type I muscle glycogen content (GR). VO2 was measured breath-by-breath for the determination of VO2 kinetics using a double-exponential model with independent time delays. VO2 was higher in the GR trial compared to the CON trial as a result of augmented phase I and II amplitudes, with no difference between trials in the phase II time constant or the magnitude of the slow component. The mean power frequency (MPF) of electromyography activity for the vastus medialis increased over time during both trials, with a greater rate of increase observed in the GR trial compared to the CON trial. The results suggest that the recruitment of additional type II motor units contributed to the slow component in both trials. An increase in fat metabolism and augmented type II motor unit recruitment contributed to the higher VO2 in the GR trial. However, the greater rate of increase in the recruitment of type II motor units in the GR trial may not have been of sufficient magnitude to further elevate the slow component when VO2 was already high and approaching VO2peak .

  17. Endurance running performance in athletes with asthma.

    PubMed

    Freeman, W; Williams, C; Nute, M G

    1990-01-01

    Laboratory assessment was made during maximal and submaximal exercise on 16 endurance trained male runners with asthma (aged 35 +/- 9 years) (mean +/- S.D.). Eleven of these asthmatic athletes had recent performance times over a half-marathon, which were examined in light of the results from the laboratory tests. The maximum oxygen uptake (VO2max) of the group was 61.8 +/- 6.3 ml kg-1 min-1 and the maximum ventilation (VEmax) was 138.7 +/- 24.7 l min-1. These maximum cardio-respiratory responses to exercise were positively correlated to the degree of airflow obstruction, defined as the forced expiratory volume in 1 s (expressed as a percentage of predicted normal). The half-marathon performance times of 11 of the athletes ranged from those of recreational to elite runners (82.4 +/- 8.8 min, range 69-94). Race pace was correlated with VO2max (r = 0.863, P less than 0.01) but the highest correlation was with the running velocity at a blood lactate concentration of 2 mmol l-1 (r = 0.971, P less than 0.01). The asthmatic athletes utilized 82 +/- 4% VO2max during the half-marathon, which was correlated with the %VO2max at 2 mmol l-1 blood lactate (r = 0.817, P less than 0.01). The results of this study suggest that athletes with mild to moderate asthma can possess high VO2max values and can develop a high degree of endurance fitness, as defined by their ability to sustain a high percentage of VO2max over an endurance race. In athletes with more severe airflow obstruction, the maximum ventilation rate may be reduced and so VO2max may be impaired. The athletes in the present study have adapted to this limitation by being able to sustain a higher %VO2max before the accumulation of blood lactate, which is an advantage during an endurance race. Therefore, with appropriate training and medication, asthmatics can successfully participate in endurance running at a competitive level.

  18. Peak oxygen consumption measured during the stair-climbing test in lung resection candidates.

    PubMed

    Brunelli, Alessandro; Xiumé, Francesco; Refai, Majed; Salati, Michele; Di Nunzio, Luca; Pompili, Cecilia; Sabbatini, Armando

    2010-01-01

    The stair-climbing test is commonly used in the preoperative evaluation of lung resection candidates, but it is difficult to standardize and provides little physiologic information on the performance. To verify the association between the altitude and the V(O2peak) measured during the stair-climbing test. 109 consecutive candidates for lung resection performed a symptom-limited stair-climbing test with direct breath-by-breath measurement of V(O2peak) by a portable gas analyzer. Stepwise logistic regression and bootstrap analyses were used to verify the association of several perioperative variables with a V(O2peak) <15 ml/kg/min. Subsequently, multiple regression analysis was also performed to develop an equation to estimate V(O2peak) from stair-climbing parameters and other patient-related variables. 56% of patients climbing <14 m had a V(O2peak) <15 ml/kg/min, whereas 98% of those climbing >22 m had a V(O2peak) >15 ml/kg/min. The altitude reached at stair-climbing test resulted in the only significant predictor of a V(O2peak) <15 ml/kg/min after logistic regression analysis. Multiple regression analysis yielded an equation to estimate V(O2peak) factoring altitude (p < 0.0001), speed of ascent (p = 0.005) and body mass index (p = 0.0008). There was an association between altitude and V(O2peak) measured during the stair-climbing test. Most of the patients climbing more than 22 m are able to generate high values of V(O2peak) and can proceed to surgery without any additional tests. All others need to be referred for a formal cardiopulmonary exercise test. In addition, we were able to generate an equation to estimate V(O2peak), which could assist in streamlining the preoperative workup and could be used across different settings to standardize this test. Copyright (c) 2010 S. Karger AG, Basel.

  19. Thermochromic VO2 Films Deposited by RF Magnetron Sputtering Using V2O3 or V2O5 Targets

    NASA Astrophysics Data System (ADS)

    Shigesato, Yuzo; Enomoto, Mikiko; Odaka, Hidehumi

    2000-10-01

    Thermochromic monoclinic-tetragonal VO2 films were successfully deposited on glass substrates with high reproducibility by rf magnetron sputtering using V2O3 or V2O5 targets. In the case of reactive sputtering using a V-metal target, the VO2 films could be obtained only under the very narrow deposition conditions of the “transition region” where the deposition rate decreases drastically with increasing oxygen gas flow rate. In the case of a V2O3 target, polycrystalline VO2 films with a thickness of 400 to 500 nm were obtained by the introduction of oxygen gas [O2/(Ar+O2)=1--1.5%], whereas hydrogen gas [H2/(Ar+H2)=2.5--10%] was introduced in the case of a V2O5 target. Furthermore, the VO2 films were successfully grown heteroepitaxially on a single-crystal sapphire [α-Al2O3(001)] substrate, where the epitaxial relationship was confirmed to be VO2(010)[100]\\parallelAl2O3(001)[100], [010], [\\bar{1}\\bar{1}0] by an X-ray diffraction pole figure measurement. The resistivity ratio between semiconductor and metal phases for the heteroepitaxial VO2 films was much larger than the ratio of the polycrystalline films on glass substrates under the same deposition conditions.

  20. High-Power Nd:GdVO4 Innoslab Continuous-Wave Laser under Direct 880 nm Pumping

    NASA Astrophysics Data System (ADS)

    Deng, Bo; Zhang, Heng-Li; Xu, Liu; Mao, Ye-Fei; He, Jing-Liang; Xin, Jian-Guo

    2014-11-01

    A high-power cw end-pumped laser device is demonstrated with a slab crystal of Nd:GdVO4 operating at 1063 nm. Diode laser stacks at 880 nm are used to pump Nd:GdVO4 into emitting level 4F3/2. The 149 W output power is presented when the absorbed pump power is 390 W and the optical-to-optical conversion efficiency is 38.2%. When the output power is 120 W, the M2 factors are 2.3 in both directions. Additionally, mode overlap inside the resonator is analyzed to explain the beam quality deterioration.

  1. Strain Effects in Epitaxial VO2 Thin Films on Columnar Buffer-Layer TiO2/Al2O3 Virtual Substrates.

    PubMed

    Breckenfeld, Eric; Kim, Heungsoo; Burgess, Katherine; Charipar, Nicholas; Cheng, Shu-Fan; Stroud, Rhonda; Piqué, Alberto

    2017-01-18

    Epitaxial VO 2 /TiO 2 thin film heterostructures were grown on (100) (m-cut) Al 2 O 3 substrates via pulsed laser deposition. We have demonstrated the ability to reduce the semiconductor-metal transition (SMT) temperature of VO 2 to ∼44 °C while retaining a 4 order of magnitude SMT using the TiO 2 buffer layer. A combination of electrical transport and X-ray diffraction reciprocal space mapping studies help examine the specific strain states of VO 2 /TiO 2 /Al 2 O 3 heterostructures as a function of TiO 2 film growth temperatures. Atomic force microscopy and transmission electron microscopy analyses show that the columnar microstructure present in TiO 2 buffer films is responsible for the partially strained VO 2 film behavior and subsequently favorable transport characteristics with a lower SMT temperature. Such findings are of crucial importance for both the technological implementation of the VO 2 system, where reduction of its SMT temperature is widely sought, as well as the broader complex oxide community, where greater understanding of the evolution of microstructure, strain, and functional properties is a high priority.

  2. Overspeed HIIT in Lower-Body Positive Pressure Treadmill Improves Running Performance.

    PubMed

    Gojanovic, Boris; Shultz, Rebecca; Feihl, Francois; Matheson, Gordon

    2015-12-01

    Optimal high-intensity interval training (HIIT) regimens for running performance are unknown, although most protocols result in some benefit to key performance factors (running economy (RE), anaerobic threshold (AT), or maximal oxygen uptake (VO2max)). Lower-body positive pressure (LBPP) treadmills offer the unique possibility to partially unload runners and reach supramaximal speeds. We studied the use of LBPP to test an overspeed HIIT protocol in trained runners. Eleven trained runners (35 ± 8 yr, VO2max, 55.7 ± 6.4 mL·kg⁻¹·min⁻¹) were randomized to an LBPP (n = 6) or a regular treadmill (CON, n = 5), eight sessions over 4 wk of HIIT program. Four to five intervals were run at 100% of velocity at VO2max (vVO2max) during 60% of time to exhaustion at vVO2max (Tlim) with a 1:1 work:recovery ratio. Performance outcomes were 2-mile track time trial, VO2max, vVO2max, vAT, Tlim, and RE. LBPP sessions were carried out at 90% body weight. Group-time effects were present for vVO2max (CON, 17.5 vs. 18.3, P = 0.03; LBPP, 19.7 vs. 22.3 km·h⁻¹; P < 0.001) and Tlim (CON, 307.0 vs. 404.4 s, P = 0.28; LBPP, 444.5 vs. 855.5, P < 0.001). Simple main effects for time were present for field performance (CON, -18; LBPP, -25 s; P = 0.002), VO2max (CON, 57.6 vs. 59.6; LBPP, 54.1 vs. 55.1 mL·kg⁻¹·min⁻¹; P = 0.04) and submaximal HR (157.7 vs. 154.3 and 151.4 vs. 148.5 bpm; P = 0.002). RE was unchanged. A 4-wk HIIT protocol at 100% vVO2max improves field performance, vVO2max, VO2max and submaximal HR in trained runners. Improvements are similar if intervals are run on a regular treadmill or at higher speeds on a LPBB treadmill with 10% body weight reduction. LBPP could provide an alternative for taxing HIIT sessions.

  3. The aerobic demand of backstroke swimming, and its relation to body size, stroke technique, and performance.

    PubMed

    Smith, H K; Montpetit, R R; Perrault, H

    1988-01-01

    Few studies have examined the aerobic demand of backstroke swimming, and its relation to body morphology, technique, or performance. The aims of this study were thus to: i) describe the aerobic demand of backstroke swimming in proficient swimmers at high velocities; ii) assess the effects of body size and stroke technique on submaximal and maximal O2 costs, and; iii) test for a relationship between submaximal O2 costs and maximal performance. Sixteen male competitive swimmers were tested during backstroke swimming at velocities from 1.0 to 1.4 m.s-1. Results showed that VO2 increased linearly with velocity (m.s-1) following the equation VO2 = 6.28v - 3.81 (r = 0.77, SEE/Y = 14.9%). VO2 was also related to the subjects' body mass, height, and armspan. Longer distances per stroke were associated with lower O2 costs, and better maximal performances. A significant relation was found between VO2 at 1.1 m.s-1, adjusted for body mass, and 400 m performance (r = -0.78). Submaximal VO2 was also related to reported times for 100 m and 200 m races. Multiple correlation analyses indicated that VO2 at 1.1 m.s-1 and VO2max accounted for up to 78% of the variance in maximal performances. These results suggest that the assessment of submaximal and maximal VO2 during backstroke swimming may be of value in the training and testing programs of competitive swimmers.

  4. Measurement of systemic oxygen consumption in patients during extracorporeal membrane oxygenation--description of a new method and the first clinical observations.

    PubMed

    Cheypesh, A; Yu, X; Li, J

    2014-01-01

    Extracorporeal membrane oxygenation (ECMO) provides temporary life-saving support for patients with severe cardiac failure, but is associated with significant morbidity and mortality. While ECMO enables oxygen delivery (DO2), little is known about oxygen consumption (VO2), largely due to technical difficulties. We aimed to introduce the adaptation of respiratory mass spectrometry to measure VO2 in patients during ECMO and to use this unique model to determine the pathological dependency of VO2 on DO2 in humans. Respiratory mass spectrometry remains the 'state-of-the-art' method, allowing the highly sensitive and rapid measurement of VO2 in critically ill patients. The principle and design of the respiratory mass spectrometer are described, together with the setting up of this machine with the ECMO oxygenator and the native lungs of the patients. In two patients with severe dilated cardiomyopathy and little cardiac contraction, the decrease in pump flow and, hence, DO2 by 20% was associated with a decrease in VO2 by 5% and 8%, respectively, whereas the increase in pump flow was not associated with any significant change in VO2. The direct measurement of VO2 by respiratory mass spectrometry in ECMO patients provides a unique technique for clinical research on the metabolism and VO2-DO2 relationship in this special group of critically ill patients. Our pilot study is the first to demonstrate a pathological dependency of VO2 on DO2 in humans. Further studies are warranted with this technique to examine the changes and the factors affecting systemic oxygen transport in patients during ECMO.

  5. Direct and continuous synthesis of VO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Powell, M. J.; Marchand, P.; Denis, C. J.; Bear, J. C.; Darr, J. A.; Parkin, I. P.

    2015-11-01

    Monoclinic VO2 nanoparticles are of interest due to the material's thermochromic properties, however, direct synthesis routes to VO2 nanoparticles are often inaccessible due to the high synthesis temperatures or long reaction times required. Herein, we present a two-step synthesis route for the preparation of monoclinic VO2 nanoparticles using Continuous Hydrothermal Flow Synthesis (CHFS) followed by a short post heat treatment step. A range of particle sizes, dependent on synthesis conditions, were produced from 50 to 200 nm by varying reaction temperatures and the residence times in the process. The nanoparticles were characterised by powder X-ray diffraction, Raman and UV/Vis spectroscopy, transmission electron microscopy (TEM), scanning electron microscopy (SEM) and differential scanning calorimetry (DSC). The nanoparticles were highly crystalline with rod and sphere-like morphologies present in TEM micrographs, with the size of both the rod and spherical particles being highly dependent on both reaction temperature and residence time. SEM micrographs showed the surface of the powders produced from the CHFS process to be highly uniform. The samples were given a short post synthesis heat treatment to ensure that they were phase pure monoclinic VO2, which led to them exhibiting a large and reversible switch in optical properties (at near-IR wavelengths), which suggests that if such materials can be incorporated into coatings or in composites, they could be used for fenestration in architectural applications.

  6. Direct and continuous synthesis of VO2 nanoparticles.

    PubMed

    Powell, M J; Marchand, P; Denis, C J; Bear, J C; Darr, J A; Parkin, I P

    2015-11-28

    Monoclinic VO2 nanoparticles are of interest due to the material's thermochromic properties, however, direct synthesis routes to VO2 nanoparticles are often inaccessible due to the high synthesis temperatures or long reaction times required. Herein, we present a two-step synthesis route for the preparation of monoclinic VO2 nanoparticles using Continuous Hydrothermal Flow Synthesis (CHFS) followed by a short post heat treatment step. A range of particle sizes, dependent on synthesis conditions, were produced from 50 to 200 nm by varying reaction temperatures and the residence times in the process. The nanoparticles were characterised by powder X-ray diffraction, Raman and UV/Vis spectroscopy, transmission electron microscopy (TEM), scanning electron microscopy (SEM) and differential scanning calorimetry (DSC). The nanoparticles were highly crystalline with rod and sphere-like morphologies present in TEM micrographs, with the size of both the rod and spherical particles being highly dependent on both reaction temperature and residence time. SEM micrographs showed the surface of the powders produced from the CHFS process to be highly uniform. The samples were given a short post synthesis heat treatment to ensure that they were phase pure monoclinic VO2, which led to them exhibiting a large and reversible switch in optical properties (at near-IR wavelengths), which suggests that if such materials can be incorporated into coatings or in composites, they could be used for fenestration in architectural applications.

  7. Prediction of Maximal Aerobic Capacity in Severely Burned Children

    PubMed Central

    Porro, Laura; Rivero, Haidy G.; Gonzalez, Dante; Tan, Alai; Herndon, David N.; Suman, Oscar E.

    2011-01-01

    Introduction Maximal oxygen uptake (VO2 peak) is an indicator of cardiorespiratory fitness, but requires expensive equipment and a relatively high technical skill level. Purpose The aim of this study is to provide a formula for estimating VO2 peak in burned children, using information obtained without expensive equipment. Methods Children, with ≥40% total surface area burned (TBSA), underwent a modified Bruce treadmill test to asses VO2 peak at 6 months after injury. We recorded gender, age, %TBSA, %3rd degree burn, height, weight, treadmill time, maximal speed, maximal grade, and peak heart rate, and applied McHenry’s select algorithm to extract important independent variables and Robust multiple regression to establish prediction equations. Results 42 children; 7 to 17 years old were tested. Robust multiple regression model provided the equation: VO2=10.33 – 0.62 *Age (years) + 1.88 * Treadmill Time (min) + 2.3 (gender; Females = 0, Males = 1). The correlation between measured and estimated VO2 peak was R=0.80. We then validated the equation with a group of 33 burned children, which yielded a correlation between measured and estimated VO2 peak of R=0.79. Conclusions Using only a treadmill and easily gathered information, VO2 peak can be estimated in children with burns. PMID:21316155

  8. [Effects of a high intensity interval training on the aerobic capacity of adolescents].

    PubMed

    Huerta Ojeda, Álvaro; Galdames Maliqueo, Sergio; Cataldo Guerra, Marianela; Barahona Fuentes, Guillermo; Rozas Villanueva, Tania; Cáceres Serrano, Pablo

    2017-08-01

    If aerobic capacity is stimulated early in life, maximal oxygen consumption during adulthood is assured. To analyze the effects of a high intensity interval training (HIIT) in adolescents on the maximal oxygen consumption (VO2max) measured using the 20-m shuttle run test (20mSRT). Twenty eight teenagers aged 13 ± 0.6 years were divided in two groups of 14 subjects each. One group was to a 16 sessions of HIIT interval training based on their individual maximal aerobic speed and the other continued with their usual exercise done at school. At baseline and the end of the intervention VO2max was measured using the 20mSTR. At the end of the intervention, the trained teenagers significantly improved their VO2max and the time spent in the 20mSTR. A HIIT program based on the individual maximal aerobic speed improves VO2max in adolescents.

  9. A Thermal Diode Based on Nanoscale Thermal Radiation.

    PubMed

    Fiorino, Anthony; Thompson, Dakotah; Zhu, Linxiao; Mittapally, Rohith; Biehs, Svend-Age; Bezencenet, Odile; El-Bondry, Nadia; Bansropun, Shailendra; Ben-Abdallah, Philippe; Meyhofer, Edgar; Reddy, Pramod

    2018-05-23

    In this work we demonstrate thermal rectification at the nanoscale between doped Si and VO 2 surfaces. Specifically, we show that the metal-insulator transition of VO 2 makes it possible to achieve large differences in the heat flow between Si and VO 2 when the direction of the temperature gradient is reversed. We further show that this rectification increases at nanoscale separations, with a maximum rectification coefficient exceeding 50% at ∼140 nm gaps and a temperature difference of 70 K. Our modeling indicates that this high rectification coefficient arises due to broadband enhancement of heat transfer between metallic VO 2 and doped Si surfaces, as compared to narrower-band exchange that occurs when VO 2 is in its insulating state. This work demonstrates the feasibility of accomplishing near-field-based rectification of heat, which is a key component for creating nanoscale radiation-based information processing devices and thermal management approaches.

  10. Individual Responses to Completion of Short-Term and Chronic Interval Training: A Retrospective Study

    PubMed Central

    Astorino, Todd A.; Schubert, Matthew M.

    2014-01-01

    Alterations in maximal oxygen uptake (VO2max), heart rate (HR), and fat oxidation occur in response to chronic endurance training. However, many studies report frequent incidence of “non-responders” who do not adapt to continuous moderate exercise. Whether this is the case in response to high intensity interval training (HIT), which elicits similar adaptations as endurance training, is unknown. The aim of this retrospective study was to examine individual responses to two paradigms of interval training. In the first study (study 1), twenty active men and women (age and baseline VO2max = 24.0±4.6 yr and 42.8±4.8 mL/kg/min) performed 6 d of sprint interval training (SIT) consisting of 4–6 Wingate tests per day, while in a separate study (study 2), 20 sedentary women (age and baseline VO2max = 23.7±6.2 yr and 30.0±4.9 mL/kg/min) performed 12 wk of high-volume HIT at workloads ranging from 60–90% maximal workload. Individual changes in VO2max, HR, and fat oxidation were examined in each study, and multiple regression analysis was used to identify predictors of training adaptations to SIT and HIT. Data showed high frequency of increased VO2max (95%) and attenuated exercise HR (85%) in response to HIT, and low frequency of response for VO2max (65%) and exercise HR (55%) via SIT. Frequency of improved fat oxidation was similar (60–65%) across regimens. Only one participant across both interventions showed non-response for all variables. Baseline values of VO2max, exercise HR, respiratory exchange ratio, and body fat were significant predictors of adaptations to interval training. Frequency of positive responses to interval training seems to be greater in response to prolonged, higher volume interval training compared to similar durations of endurance training. PMID:24847797

  11. Maximum Oxygen Uptake During and After Long-Duration Space Flight

    NASA Technical Reports Server (NTRS)

    Moore, Alan D., Jr.; Evetts, Simon N.; Feiveson, Alan H.; Lee, Stuart M. C.; McCleary. Frank A.; Platts, Steven H.

    2010-01-01

    Decreased maximum oxygen consumption (VO2max) during and after space flight may impair a crewmember s ability to perform mission-critical work that is high intensity and/or long duration in nature (Human Research Program Integrated Research Plan Risk 2.1.2: Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity). When VO2max was measured in Space Shuttle experiments, investigators reported that it did not change during short-duration space flight but decreased immediately after flight. Similar conclusions, based on the heart rate (HR) response of Skylab crewmembers, were made previously concerning long-duration space flight. Specifically, no change in the in-flight exercise HR response in 8 of 9 Skylab crewmembers indicated that VO2max was maintained during flight, but the elevated exercise HR after flight indicated that VO2max was decreased after landing. More recently, a different pattern of in-flight exercise HR response, and assumed changes in VO2max, emerged from routine testing of International Space Station (ISS) crewmembers. Most ISS crewmembers experience an elevated in-flight exercise HR response early in their mission, with a gradual return toward preflight levels as the mission progresses. Similar to previous reports, exercise HR is elevated after ISS missions and returns to preflight levels by 30 days after landing. VO2max has not been measured either during or after long-duration space flight. The purposes of the ISS VO2max experiment are (1) to measure VO2max during and after long-duration spaceflight, and (2) to determine if submaximal exercise test results can be used to accurately estimate VO 2max.

  12. The Effects of Vanadium Pentoxide to Oxalic Acid Ratio and Different Atmospheres on the Formation of VO2 Nanopowders Synthesized via Sol-Gel Method

    NASA Astrophysics Data System (ADS)

    Vostakola, Mohsen Fallah; Yekta, Bijan Eftekhari; Mirkazemi, Seyed Mohammad

    2017-11-01

    Thermochromic VO2 nanopowders were synthesized via the sol-gel method through mixing oxalic acid and vanadium pentoxide in ethanol. We investigated the effect of oxalic acid to vanadium pentoxide ratio on the formation of final product and found that excessive oxalic acid reduced the final product from VO2 to V2O3. Because decreasing the oxalic acid to vanadium pentoxide ratio is a time-consuming process, oxygen was introduced by using a low-porosity alumina tube. The heat treatment was performed inside an electrical tube furnace and in a variety of atmospheres, including pure nitrogen (99.999% purity) and nitrogen containing 5 vol.%, 10 vol.%, and 15 vol.% hydrogen. According to x-ray diffraction (XRD) results, the appropriate atmosphere for synthesizing VO2 nanopowder was the one which contained 10 vol.% hydrogen. In order to decrease the transition temperature in VO2 from 63.5°C to room temperature, W6+ doping was done by adding different amounts of tungstic acid sol to vanadium sol precursor. Differential scanning calorimetry (DSC) results showed that W6+ reduced the transition temperature of VO2 approximately 23°C/wt.%. Lattice straining estimated from XRD results confirmed that VO2 was doped. XRD results at 25°C and 100°C along with DSC results indicated that VO2 was transformed from a low-temperature monoclinic phase to a high-temperature rutile one along this temperature interval.

  13. Reduction in peak oxygen uptake after prolonged bed rest

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Kozlowski, S.

    1982-01-01

    The hypothesis that the magnitude of the reduction in peak oxygen uptake (VO2) after bed rest is directly proportional to the level of pre-bed rest peak VO2 is tested. Complete pre and post-bed rest working capacity and body weight data were obtained from studies involving 24 men (19-24 years old) and 8 women (23-34 years old) who underwent bed rest for 14-20 days with no remedial treatments. Results of regression analyses of the present change in post-bed rest peak VO2 on pre-bed rest peak VO2 with 32 subjects show correlation coefficients of -0.03 (NS) for data expressed in 1/min and -0.17 for data expressed in ml/min-kg. In addition, significant correlations are found that support the hypothesis only when peak VO2 data are analyzed separately from studies that utilized the cycle ergometer, particularly with subjects in the supine position, as opposed to data obtained from treadmill peak VO2 tests. It is concluded that orthostatic factors, associated with the upright body position and relatively high levels of physical fitness from endurance training, appear to increase the variability of pre and particularly post-bed rest peak VO2 data, which would lead to rejection of the hypothesis.

  14. Sex differences in the effects of 12 weeks sprint interval training on body fat mass and the rates of fatty acid oxidation and VO2max during exercise.

    PubMed

    Bagley, Liam; Slevin, Mark; Bradburn, Steven; Liu, Donghui; Murgatroyd, Chris; Morrissey, George; Carroll, Michael; Piasecki, Mathew; Gilmore, William S; McPhee, Jamie S

    2016-01-01

    The purpose of this study was to examine whether very short duration, very high intensity sprint interval training (SIT) leads to loss of body fat mass in association with improvements to VO 2 max and fatty acid oxidation, and to assess the extent of sex dimorphism in these physiological responses. A total of 24 men and 17 women (mean (SEM) age: 39 (±2) years; body mass index 24.6 (0.6)) completed measurements of the maximal rate of oxygen uptake (VO 2 max) and fatty acid oxidation (FATmax). Body fat and lean mass were measured by dual emission x-ray absorptiometry, and fasting blood lipid, glucose and insulin profiles were assessed before and after training. SIT consisted of 4×20 s sprints on a cycle ergometer at approximately 175% VO 2 max, three times per week for 12 weeks. Fat mass decreased by 1.0 kg, although men lost statistically significantly more fat than women both when expressed in Kg and as % body fat. VO 2 max increased by around 9%, but women improved VO 2 max significantly more than men. FATmax improved by around 13%, but fasting plasma glucose, insulin, total triglyceride, total cholesterol and high-density lipoprotein (HDL) did not change after training, while low-density lipoprotein decreased by 8% (p=0.028) and the HDL:Total Cholesterol ratio improved by 6%. There were no sex differences in these metabolic responses to training. These results show lower body fat %, and higher rates of fatty acid oxidation and VO 2 max after 12 weeks of training for just 4 min per week. Notably, women improved VO 2 max more than men, while men lost more fat than women.

  15. Sex differences in the effects of 12 weeks sprint interval training on body fat mass and the rates of fatty acid oxidation and VO2max during exercise

    PubMed Central

    Bagley, Liam; Slevin, Mark; Bradburn, Steven; Liu, Donghui; Murgatroyd, Chris; Morrissey, George; Carroll, Michael; Piasecki, Mathew; Gilmore, William S; McPhee, Jamie S

    2016-01-01

    Background The purpose of this study was to examine whether very short duration, very high intensity sprint interval training (SIT) leads to loss of body fat mass in association with improvements to VO2max and fatty acid oxidation, and to assess the extent of sex dimorphism in these physiological responses. Methods A total of 24 men and 17 women (mean (SEM) age: 39 (±2) years; body mass index 24.6 (0.6)) completed measurements of the maximal rate of oxygen uptake (VO2max) and fatty acid oxidation (FATmax). Body fat and lean mass were measured by dual emission x-ray absorptiometry, and fasting blood lipid, glucose and insulin profiles were assessed before and after training. SIT consisted of 4×20 s sprints on a cycle ergometer at approximately 175% VO2max, three times per week for 12 weeks. Results Fat mass decreased by 1.0 kg, although men lost statistically significantly more fat than women both when expressed in Kg and as % body fat. VO2max increased by around 9%, but women improved VO2max significantly more than men. FATmax improved by around 13%, but fasting plasma glucose, insulin, total triglyceride, total cholesterol and high-density lipoprotein (HDL) did not change after training, while low-density lipoprotein decreased by 8% (p=0.028) and the HDL:Total Cholesterol ratio improved by 6%. There were no sex differences in these metabolic responses to training. Conclusions These results show lower body fat %, and higher rates of fatty acid oxidation and VO2max after 12 weeks of training for just 4 min per week. Notably, women improved VO2max more than men, while men lost more fat than women. PMID:27900150

  16. TiO2/BiVO4 Nanowire Heterostructure Photoanodes Based on Type II Band Alignment

    PubMed Central

    2016-01-01

    Metal oxides that absorb visible light are attractive for use as photoanodes in photoelectrosynthetic cells. However, their performance is often limited by poor charge carrier transport. We show that this problem can be addressed by using separate materials for light absorption and carrier transport. Here, we report a Ta:TiO2|BiVO4 nanowire photoanode, in which BiVO4 acts as a visible light-absorber and Ta:TiO2 acts as a high surface area electron conductor. Electrochemical and spectroscopic measurements provide experimental evidence for the type II band alignment necessary for favorable electron transfer from BiVO4 to TiO2. The host–guest nanowire architecture presented here allows for simultaneously high light absorption and carrier collection efficiency, with an onset of anodic photocurrent near 0.2 V vs RHE, and a photocurrent density of 2.1 mA/cm2 at 1.23 V vs RHE. PMID:27163032

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanjeewa, Liurukara. D.; McGuire, Michael A.; McMillen, Colin D.

    We synthesized new complex manganese vanadate materials as high-quality single crystals in multi-millimeter lengths using a high-temperature, high-pressure hydrothermal method. We grew one compound, Mn 5(VO 4) 2(OH) 4, from Mn 2O 3 and V 2O 5 in 3 M CsOH at 580 °C and 1.5 kbar. Changing the mineralizer to 1 M CsOH/3MCsCl leads to the formation of another product, Mn 6O(VO 4) 2(OH). Both compounds were structurally characterized by single-crystal X-ray diffraction (Mn 5(VO 4) 2(OH) 4: C2/m, Z = 2, a = 9.6568(9) Å, b = 9.5627(9) Å, c = 5.4139(6) Å, β = 98.529(8)°; Mn 6O(VOmore » 4) 2(OH): P21/m, Z = 2, a = 8.9363(12) Å, b = 6.4678(8) Å, c = 10.4478(13) Å, β = 99.798(3)°), revealing interesting low-dimensional transition-metal features. Mn 5(VO 4) 2(OH) 4 possesses complex honeycomb-type Mn–O layers, built from edge-sharing [MnO 6] octahedra in the bc plane, with bridging vanadate groups connecting these layers along the a-axis. Mn 6O(VO 4) 2(OH) presents a more complicated structure with both octahedral [MnO 6] and trigonal bipyramidal [MnO 5] units. A different pattern of planar honeycomb sheets are formed by edge-shared [MnO6] octahedra, and these sublattices are connected through edge-shared dimers of [MnO 5] trigonal bipyramids to form corrugated sheets. Vanadate groups again condense the sheets into a three-dimensional framework. Infrared and Raman spectroscopies indicated the presence of OH groups and displayed characteristic Raman scattering due to vanadate groups. Furthermore, temperature-dependent magnetic studies indicated Curie–Weiss behavior above 100 K with significant anti-ferromagnetic coupling for both compounds, with further complex magnetic behavior at lower temperatures. The data indicate canted anti-ferromagnetic order below 57 K in Mn 5(VO 4) 2(OH) 4 and below 45 K in Mn 6O(VO 4) 2(OH). Members of another class of compounds, K 2M 3(VO 4) 2(OH) 2 (M = Mn, Co), also containing a honeycomb-type sublattice, were also synthesized to allow a comparison of the structural features across all three structure types and to demonstrate extension to other transition metals.« less

  18. High pressure spectroscopic studies of phase transition in VO2

    NASA Astrophysics Data System (ADS)

    Basu, Raktima; Mishra, K. K.; Ravindran, T. R.; Dhara, Sandip

    2018-04-01

    Vanadium dioxide (VO2) exhibits a reversible first-order metal to insulator transition (MIT) at a technologically important temperature of 340K. A structural phase transition (SPT) from monoclinic M1 to rutile tetragonal R is also reported via another two intermediate phases of monoclinic M2 and triclinic T. Metastable monoclinic M2 phase of VO2 was synthesized by Mg doping in the vapour transport process. Raman spectroscopic measurements were carried out at high pressure on V1-xMgxO2 microrods. Two reversible structural phase transitions from monoclinic M2 to triclinic T at 1.6 GPa and T to monoclinic M1 at 3.2 GPa are observed and are explained by structural relaxation of the strained phases.

  19. Switchable vanadium oxide films by a sol-gel process

    NASA Astrophysics Data System (ADS)

    Partlow, D. P.; Gurkovich, S. R.; Radford, K. C.; Denes, L. J.

    1991-07-01

    Thin polycrystalline films of VO2 and V2O3 were deposited on a variety of substrates using a sol-gel process. The orientation, microstructure, optical constants, and optical and electrical switching behavior are presented. These films exhibited sharp optical switching behavior even on an amorphous substrate such as fused silica. The method yields reproducible results and is amenable to the coating of large substrates and curved surfaces such as mirrors and lenses.

  20. BiVO4 microstructures with various morphologies: Synthesis and characterization

    NASA Astrophysics Data System (ADS)

    Wu, Min; Jing, Qifeng; Feng, Xinyan; Chen, Limiao

    2018-01-01

    Bismuth vanadate (BiVO4) microstructures with dumbbell, rod, ellipsoid, sphere, and cake-like morphologies have been successfully fabricated by using a surfactant-free hydrothermal method, in which the morphology of the BiVO4 microstructures can be tuned by simply varying the molar ratio of Bi(NO)3·5H2O to NaVO3 in the starting materials. Based on a series of contrast experiments, the probable formation mechanism of the BiVO4 microstructures with multiple shapes have been proposed. The photocatalytic performances of the as-prepared BiVO4 microstructures have been evaluated by studying the degradation of Rhodamine B solutions under visible light irradiation. The results reveal that the cake-like BiVO4 microstructures exhibit the higher photocatalytic activity than other BiVO4 microstructures due to its high surface area and unique morphology.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanov, Alexander S.; Bryantsev, Vyacheslav S.

    Uranium is used as the basic fuel for nuclear power plants, which generate significant amounts of electricity and have life cycle carbon emissions that are as low as renewable energy sources. However, the extraction of this valuable energy commodity from the ground remains controversial, mainly because of environmental and health impacts. Alternatively, seawater offers an enormous uranium resource that may be tapped at minimal environmental cost. Nowadays, amidoxime polymers are the most widely utilized sorbent materials for large-scale extraction of uranium from seawater, but they are not perfectly selective for uranyl, UO 2 2+. In particular, the competition between UOmore » 2 2+ and VO 2+/VO2+ cations poses a significant challenge to the effi-cient mining of UO 2 2+. Thus, screening and rational design of more selective ligands must be accomplished. One of the key components in achieving this goal is the establishment of computational techniques capable of assessing ligand selec-tivity trends. Here, we report an approach based on quantum chemical calculations that achieves high accuracy in repro-ducing experimental aqueous stability constants for VO 2+/VO 2+ complexes with ten different oxygen donor lig-ands. The predictive power of the developed computational protocol was demonstrated for amidoxime-type ligands, providing greater insights into new design strategies for the development of the next generation of adsorbents with high selectivity toward UO 2 2+over VO 2+/VO 2+ ions. Furthermore, the results of calculations suggest that alkylation of amidox-ime moieties present in poly(acrylamidoxime) sorbents can be a potential route to better discrimination between the uranyl and competing vanadium ions within seawater.« less

  2. The role of the CeO 2 /BiVO 4 interface in optimized Fe–Ce oxide coatings for solar fuels photoanodes

    DOE PAGES

    Shinde, A.; Li, G.; Zhou, L.; ...

    2016-09-09

    Solar fuel generators entail a high degree of materials integration, and efficient photoelectrocatalysis of the constituent reactions hinges upon the establishment of highly functional interfaces. Our recent application of high throughput experimentation to interface discovery for solar fuels photoanodes has revealed several surprising and promising mixed-metal oxide coatings for BiVO 4. Furthermore, when using sputter deposition of composition and thickness gradients on a uniform BiVO 4 film, we systematically explore photoanodic performance as a function of the composition and loading of Fe–Ce oxide coatings. This combinatorial materials integration study not only enhances the performance of this new class of materialsmore » but also identifies CeO 2 as a critical ingredient that merits detailed study. A heteroepitaxial CeO 2(001)/BiVO4(010) interface is identified in which Bi and V remain fully coordinated to O such that no surface states are formed. Ab initio calculations of the integrated materials and inspection of the electronic structure reveals mechanisms by which CeO 2 facilitates charge transport while mitigating deleterious recombination. Our results support the observations that addition of Ce to BiVO 4 coatings greatly enhances photoelectrocatalytic activity, providing an important strategy for developing a scalable solar fuels technology.« less

  3. Applied physiology of triathlon.

    PubMed

    O'Toole, M L; Douglas, P S

    1995-04-01

    The triathlon is a 3-event endurance sport in which athletes compete sequentially in swimming, cycling and running. The primary determinant of success is the ability to sustain a high rate of energy expenditure for prolonged periods of time. Exercise training-induced physiological adaptations in virtually all systems of the body allow the athlete to accomplish this. Aerobic capacity (measured as maximal oxygen uptake, VO2max), economy of motion (submaximal VO2) and fractional utilisation of maximal capacity (%VO2max) reflect the integrated responses of these physiological adaptations. Numerous studies have reported relatively high mean VO2max values for various groups of triathletes that are comparable to those reported for athletes in single-event endurance sports and clearly above those reported for untrained individuals. In shorter distance triathlons and in studies using recreational (rather than elite) triathletes, VO2max is related to performance in the corresponding event of the triathlon (e.g. tethered swimming VO2max with swim time). In longer events and with more elite triathletes, VO2max correlates less well with performance. The physiological adaptations that correspond to and facilitate improved VO2max occur centrally in the cardiovascular system, centred on increased maximal cardiac output, and peripherally in the metabolic systems, centred around increased arterio-venous O2 (a-v O2) difference. While a high VO2max in individuals is clearly of importance to triathlon performance, energy output must be sustained for long periods of time, making economy of motion also very important. Studies suggests that competitive swimmers have better swimming economy than triathletes. However, since many triathletes have previously been competitive swimmers this finding is questionable. The finding suggests that triathletes from nonswimming backgrounds would benefit from improving swimming technique rather than concentrating training workouts solely on distance. In cycling and running, comparison studies have not been done. Economy of motion in swimming, cycling and running have all been found to be correlated with comparable event performance. Training to improve swimming economy can be done without prior exercise, but training to improve swimming economy can be done without prior exercise, but training to improve cycling and running economy should take the multimode nature of a triathlon into consideration. That is, swimming should precede cycling economy training, and cycling should precede running economy training. Cardiovascular, metabolic and neuromuscular adaptations are the main physiological correlates of improved movement economy. Since exercise-induced stress on most physiological systems is based on relative, rather than absolute, exercise intensity, training and racing intensities are frequently quantified as a percentage of maximal capacity of %VO2max.(ABSTRACT TRUNCATED AT 400 WORDS)

  4. Synthesis of LaVO4/TiO2 heterojunction nanotubes by sol-gel coupled with hydrothermal method for photocatalytic air purification.

    PubMed

    Zou, Xuejun; Li, Xinyong; Zhao, Qidong; Liu, Shaomin

    2012-10-01

    With the aim of improving the effective utilization of visible light, the LaVO(4)/TiO(2) heterojunction nanotubes were fabricated by sol-gel coupled with hydrothermal method. The photocatalytic ability was demonstrated through catalytic removal of gaseous toluene species. The nanotube samples were characterized by scanning electron microscope (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), surface photovoltage (SPV), Raman spectra and N(2) adsorption-desorption measurements. The characterization results showed that the samples with high specific surface areas were of typical nanotubular morphology, which would lead to the high separation and transfer efficiency of photo induced electron-hole pairs. The as-prepared nanotubes exhibited high photocatalytic activity in decomposing toluene species under visible light irradiation with fine photochemical stability. The enhanced photocatalytic performance of LaVO(4)/TiO(2) nanotubes might be attributed to the matching band potentials, the interconnected heterojunction of LaVO(4) versus TiO(2), and the large specific surface areas of nanotubes. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Effects of electrical stimulation on VO2 kinetics and delta efficiency in healthy young men

    PubMed Central

    Perez, M; Lucia, A; Santalla, A; Chicharro, J

    2003-01-01

    Objective: To determine the effects of electrical stimulation (ES) on oxygen uptake (VO2) kinetics and delta efficiency (DE) during gradual exercise. The hypothesis was that ES would attenuate the VO2-workload relation and improve DE. Methods: Fifteen healthy, untrained men (mean (SD) age 22 (5) years) were selected. Ten were electrostimulated on both quadriceps muscles with a frequency of 45–60 Hz, with 12 seconds of stimulation followed by eight seconds recovery for a total of 30 minutes a day, three days a week for six weeks. The remaining five subjects were assigned to a control group. A standardised exercise test on a cycle ergometer (ramp protocol, workload increases of 20 W/min) was performed by each subject before and after the experimental period. The slope of the VO2-power output (W) relation (ΔVO2/ΔW) and DE were calculated in each subject at moderate to high intensities (above the ventilatory threshold—that is, from 50–60% to 100% VO2max). Results: The mean (SEM) values for ΔVO2/ΔW and DE had significantly decreased and increased respectively after the six week ES programme (p<0.05; 9.8 (0.2) v 8.6 (0.5) ml O2/W/min respectively and 27.7 (0.9) v 31.5 (1.4)% respectively). Conclusions: ES could be used as a supplementary tool to improve two of the main determinants of endurance capacity, namely VO2 kinetics and work efficiency. PMID:12663356

  6. Effect of ZnO buffer layer on phase transition properties of vanadium dioxide thin films

    NASA Astrophysics Data System (ADS)

    Zhu, Huiqun; Li, Lekang; Li, Chunbo

    2016-03-01

    VO2 thin films were prepared on ZnO buffer layers by DC magnetron sputtering at room temperature using vanadium target and post annealing at 400 °C. The ZnO buffer layers with different thickness deposited on glass substrates by magnetron sputtering have a high visible and near infrared optical transmittance. The electrical resistivity and the phase transition properties of the VO2/ZnO composite thin films in terms of temperature were investigated. The results showed that the resistivity variation of VO2 thin film with ZnO buffer layer deposited for 35 min was 16 KΩ-cm. The VO2/ZnO composite thin films exhibit a reversible semiconductor-metal phase transition at 48 °C.

  7. Non-catalytic hydrogenation of VO2 in acid solution.

    PubMed

    Chen, Yuliang; Wang, Zhaowu; Chen, Shi; Ren, Hui; Wang, Liangxin; Zhang, Guobin; Lu, Yalin; Jiang, Jun; Zou, Chongwen; Luo, Yi

    2018-02-26

    Hydrogenation is an effective way to tune the property of metal oxides. It can conventionally be performed by doping hydrogen into solid materials with noble-metal catalysis, high-temperature/pressure annealing treatment, or high-energy proton implantation in vacuum condition. Acid solution naturally provides a rich proton source, but it should cause corrosion rather than hydrogenation to metal oxides. Here we report a facile approach to hydrogenate monoclinic vanadium dioxide (VO 2 ) in acid solution at ambient condition by placing a small piece of low workfunction metal (Al, Cu, Ag, Zn, or Fe) on VO 2 surface. It is found that the attachment of a tiny metal particle (~1.0 mm) can lead to the complete hydrogenation of an entire wafer-size VO 2 (>2 inch). Moreover, with the right choice of the metal a two-step insulator-metal-insulator phase modulation can even be achieved. An electron-proton co-doping mechanism has been proposed and verified by the first-principles calculations.

  8. Physical Workload and Work Capacity across Occupational Groups

    PubMed Central

    Brighenti-Zogg, Stefanie; Mundwiler, Jonas; Schüpbach, Ulla; Dieterle, Thomas; Wolfer, David Paul; Leuppi, Jörg Daniel; Miedinger, David

    2016-01-01

    This study aimed to determine physical performance criteria of different occupational groups by investigating physical activity and energy expenditure in healthy Swiss employees in real-life workplaces on workdays and non-working days in relation to their aerobic capacity (VO2max). In this cross-sectional study, 337 healthy and full-time employed adults were recruited. Participants were classified (nine categories) according to the International Standard Classification of Occupations 1988 and merged into three groups with low-, moderate- and high-intensity occupational activity. Daily steps, energy expenditure, metabolic equivalents and activity at different intensities were measured using the SenseWear Mini armband on seven consecutive days (23 hours/day). VO2max was determined by the 20-meter shuttle run test. Data of 303 subjects were considered for analysis (63% male, mean age: 33 yrs, SD 12), 101 from the low-, 102 from the moderate- and 100 from the high-intensity group. At work, the high-intensity group showed higher energy expenditure, metabolic equivalents, steps and activity at all intensities than the other groups (p<0.001). There were no significant differences in physical activity between the occupational groups on non-working days. VO2max did not differ across groups when stratified for gender. The upper workload limit was 21%, 29% and 44% of VO2max in the low-, moderate- and high-intensity group, respectively. Men had a lower limit than women due to their higher VO2max (26% vs. 37%), when all groups were combined. While this study did confirm that the average workload limit is one third of VO2max, it showed that the average is misrepresenting the actual physical work demands of specific occupational groups, and that it does not account for gender-related differences in relative workload. Therefore, clinical practice needs to consider these differences with regard to a safe return to work, particularly for the high-intensity group. PMID:27136206

  9. High-intensity interval training improves peak oxygen uptake and muscular exercise capacity in heart transplant recipients.

    PubMed

    Nytrøen, K; Rustad, L A; Aukrust, P; Ueland, T; Hallén, J; Holm, I; Rolid, K; Lekva, T; Fiane, A E; Amlie, J P; Aakhus, S; Gullestad, L

    2012-11-01

    Heart transplant (HTx) recipients usually have reduced exercise capacity with reported VO(2peak) levels of 50-70% predicted value. Our hypothesis was that high-intensity interval training (HIIT) is an applicable and safe form of exercise in HTx recipients and that it would markedly improve VO(2peak.) Secondarily, we wanted to evaluate central and peripheral mechanisms behind a potential VO(2peak) increase. Forty-eight clinically stable HTx recipients >18 years old and 1-8 years after HTx underwent maximal exercise testing on a treadmill and were randomized to either exercise group (a 1-year HIIT-program) or control group (usual care). The mean ± SD age was 51 ± 16 years, 71% were male and time from HTx was 4.1 ± 2.2 years. The mean VO(2peak) difference between groups at follow-up was 3.6 [2.0, 5.2] mL/kg/min (p < 0.001). The exercise group had 89.0 ± 17.5% of predicted VO(2peak) versus 82.5 ± 20.0 in the control group (p < 0.001). There were no changes in cardiac function measured by echocardiography. We have demonstrated that a long-term, partly supervised and community-based HIIT-program is an applicable, effective and safe way to improve VO(2peak) , muscular exercise capacity and general health in HTx recipients. The results indicate that HIIT should be more frequently used among stable HTx recipients in the future. © Copyright 2012 The American Society of Transplantation and the American Society of Transplant Surgeons.

  10. Biological potential of oxo-vanadium salicylediene amino-acid complexes as cytotoxic, antimicrobial, antioxidant and DNA interaction.

    PubMed

    Adam, Mohamed Shaker S; Elsawy, Hany

    2018-05-04

    New series of oxo-vanadium N-salicyledieneamino acid Schiff base complexes are synthesized and characterized. They are synthesized from the reaction of sodium salicylaldehyde-5-sulfonate, some amino acids, alanine (VOHL1), leucine (VOHL2) or glycine (VOHL3) in an aqueous media, and leucine (VOHLpy1) or tryptophan (VOHLpy2) in pyridine with vanadyl acetylacetonate. The complexes are characterized by EA, TGA, IR, UV-Visible and mass spectra, conductivity and magnetic measurements. The biological activity of the VO-complexes shows that VOHL1, VOHL2 and VOHL3 exhibit anti-proliferative effect and may be used as anticancer drugs. VO-complexes manifest high toxicity, except VOHL2 is less toxic, and could be applied for the human being. VOHL1, VOHL2 and VOHL3 display remarkable SOD like potential and act as high inhibiting reagents. VOHLpy1 and VOHLpy2 show low inhibiting potentials. VO-complexes have good anti-oxidant effect, in which VOHL3 affords the best antioxidant activity. The interaction between VO-complexes and DNA is studied spectrophotometrically and by gel electrophoresis. Binding constants and spectrophotometric parameters indicate a strong interaction between VO-complexes and DNA. VO-complexes have respectable anti-bacterial and antifungal activities, where VOHL3 shows the maximum potential. DFT calculations of VOHL1 and VOHL3 were discussed in the light of their biological activity, which are convenient with the obtained results. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Characteristics of patients with a relatively greater minimum VE/VCO2 against peak VO2% and impaired exercise tolerance.

    PubMed

    Nakade, Taisuke; Adachi, Hitoshi; Murata, Makoto; Oshima, Shigeru

    2018-05-14

    Cardiopulmonary exercise testing (CPX) is used to evaluate functional capacity and assess prognosis in cardiac patients. Ventilatory efficiency (VE/VCO 2 ) reflects ventilation-perfusion mismatch; the minimum VE/VCO 2 value (minVE/VCO 2 ) is representative of pulmonary arterial blood flow in individuals without pulmonary disease. Usually, minVE/VCO 2 has a strong relationship with the peak oxygen uptake (VO 2 ), but dissociation can occur. Therefore, we investigated the relationship between minVE/VCO 2 and predicted peak VO 2 (peak VO 2 %) and evaluated the parameters associated with a discrepancy between these two parameters. A total of 289 Japanese patients underwent CPX using a cycle ergometer with ramp protocols between 2013 and 2014. Among these, 174 patients with a peak VO 2 % lower than 70% were enrolled. Patients were divided into groups based on their minVE/VCO 2 [Low group: minVE/VCO 2  < mean - SD (38.8-5.6); High group: minVE/VCO 2  > mean + SD (38.8 + 5.6)]. The characteristics and cardiac function at rest, evaluated using echocardiography, were compared between groups. The High group had a significantly lower ejection fraction, stroke volume, and cardiac output, and higher brain natriuretic peptide, tricuspid regurgitation pressure gradient, right ventricular systolic pressure, and peak early diastolic LV filling velocity/peak atrial filling velocity ratio compared with the Low group (p's < 0.01). In addition, the Low group had a significantly higher prevalence of pleural effusion than did the High group (26 vs 11%, p < 0.01). Patients with a relatively greater minVE/VCO 2 in comparison with peak VO 2 had impaired cardiac output as well as restricted pulmonary blood flow increase during exercise, partly due to accumulated pleural effusion.

  12. Effects of three warm-up regimens of equal distance on VO2 kinetics during supramaximal exercise in Thoroughbred horses.

    PubMed

    Mukai, K; Hiraga, A; Takahashi, T; Ohmura, H; Jones, J H

    2010-11-01

    Several studies have indicated that even low-intensity warm-up increases O(2) transport kinetics and that high-intensity warm-up may not be needed in horses. However, conventional warm-up exercise for Thoroughbred races is more intense than those utilised in previous studies of equine warm-up responses. To test the hypothesis that warm-up exercise at different intensities alters the kinetics and total contribution of aerobic power to total metabolic power in subsequent supramaximal (sprint) exercise in Thoroughbred horses. Nine well-trained Thoroughbreds ran until fatigue at 115% of maximal oxygen consumption (VO2max) 10 min after warming-up under each of 3 protocols of equal running distance: 400 s at 30% VO2max (LoWU), 200 s at 60% VO2max (MoWU) and 120 s at 100% VO2max (HiWU). Variables measured during exercise were rates of O(2) and CO(2) consumption/production (VO2,VO2), respiratory exchange ratio (RER), heart rate, blood lactate concentration and accumulation rate and blood gas variables. VO2 was significantly higher in HiWU than in LoWU at the onset of the sprint exercise and HR was significantly higher in HiWU than in LoWU throughout the sprint. Accumulation of blood lactate, RER, P(a)CO(2) and PvCO2 in the first 60 s were significantly lower in HiWU than in LoWU and MoWU. There were no significant differences in stroke volume, run time or arterial-mixed venous O(2) concentration. These results suggest HiWU accelerates kinetics and reduces reliance on net anaerobic power compared with LoWU at the onset of the subsequent sprint. © 2010 EVJ Ltd.

  13. Nitrate-Containing Beetroot Juice Reduces Oxygen Consumption During Submaximal Exercise in Low but Not High Aerobically Fit Male Runners.

    PubMed

    Carriker, Colin R; Vaughan, Roger A; VanDusseldorp, Trisha A; Johnson, Kelly E; Beltz, Nicholas M; McCormick, James J; Cole, Nathan H; Gibson, Ann L

    2016-12-31

    to examine the effect of a 4-day NO3- loading protocol on the submaximal oxygen cost of both low fit and high fit participants at five different exercise intensities. participants were initially assigned to a placebo (PL; negligible NO3-) or inorganic nitrate-rich (NR; 6.2 mmol nitrate/day) group; double-blind, placebo-controlled, crossover. Participants completed three trials (T1, T2 and T3). T1 included a maximal aerobic capacity (VO2max) treadmill test. A 6-day washout, minimizing nitrate consumption, preceded T2. Each of the four days prior to T2 and T3, participants consumed either PL or NR; final dose 2.5 hours prior to exercise. A 14-day washout followed T2. T2 and T3 consisted of 5-minute submaximal treadmill bouts (45, 60, 70, 80 and 85% VO2max) determined during T1. Low fit nitrate-supplemented participants consumed less oxygen (p<0.05) at lower workloads (45% and 60% VO2max) compared to placebo trials; changes not observed in high fit participants. The two lowest intensity workloads of 45 and 60% VO2max revealed the greatest correlation (r=0.54, p=0.09 and r=0.79, p<0.05; respectively). No differences were found between conditions for heart rate, respiratory exchange ratio or rating of perceived exertion for either fitness group. Nitrate consumption promotes reduced oxygen consumption at lower exercise intensities in low fit, but not high fit males. Lesser fit individuals may receive greater benefit than higher fit participants exercising at intensities <60% VO2max.

  14. Effects of the different frequencies of whole-body vibration during the recovery phase after exhaustive exercise.

    PubMed

    Cheng, C F; Hsu, W C; Lee, C L; Chung, P K

    2010-12-01

    This study was to investigate the effects of vibration exercise on the oxygen consumption (VO2) and heart rate variability (HRV) during the recovery phase after exhaustive exercise. Twenty male college students volunteered as subjects to participate in the study. The subjects were randomly crossover assigned to perform three 10 min vibration exercises, namely non-vibration (CON, 0 Hz, 0 mm), low-frequency (LFT, 20 Hz, 0.4 mm) and high-frequency (HFT, 36 Hz, 0.4 mm) treatments immediately after an incremental exhaustive cycling exercise in separated days. The beat-to-beat HRV, blood lactate concentration and VO2 were measured during the 1-hour recovery phase. The time- and frequency-domain indices of HRV were analyzed to confirm the effects of vibration exercises on the cardiac autonomic modulation. There were no significant differences on the VO2, HRV and blood lactate concentrations at 30th minute (post-30 min) or 60th minute (post-60 min) during the recovery phase among the three treatments. There were also no significant differences on the excess post-exercise oxygen consumption (EPOC) during the recovery phase among the treatments. However, the VO2 at post-30 min in CON and LFT were significantly higher than the baseline values, whereas the VO2 in HFT returned to resting condition at the post-30 min. The results indicate that both low and high frequency vibration exercises could not improve the physiological recovery after exhaustive cycling exercise. However, the high frequency vibration exercise probably has a potential to facilitate the VO2 to return to the resting level during the recovery phase.

  15. Influence of acute moderate hypoxia on time to exhaustion at vVO2max in unacclimatized runners.

    PubMed

    Billat, V L; Lepretre, P M; Heubert, R P; Koralsztein, J P; Gazeau, F P

    2003-01-01

    Eight unacclimatized long-distance runners performed, on a level treadmill, an incremental test to determine the maximal oxygen uptake (VO2max) and the minimal velocity eliciting VO2max (vVO2max) in normoxia (N) and acute moderate hypoxia (H) corresponding to an altitude of 2,400 m (PIO 2 of 109 mmHg). Afterwards, on separate days, they performed two all-out constant velocity runs at vO2 max in a random order (one in N and the other in H). The decrease in VO2max between N and H showed a great degree of variability amongst subjects as VO2max decreased by 8.9 +/- 4 ml x min(-1) x kg)(-1) in H vs. N conditions (-15.3 +/- 6.3 % with a range from -7.9 % to -23.8 %). This decrease in VO2max was proportional to the value of VO2max (VO2max vs. delta VO2max N-H, r = 0.75, p = 0.03). The time run at vVO2max was not affected by hypoxia (483 +/- 122 vs. 506 +/- 148 s, in N and H, respectively, p = 0.37). However, the greater the decrease in vVO2max during hypoxia, the greater the runners increased their time to exhaustion at vVO2max (vVO2max N-H vs. tlim @vVO2max N-H, r = -0.75, p = 0.03). In conclusion, this study showed that there was a positive association between the extent of decrease in vVO2max, and the increase in run time at vVO2max in hypoxia.

  16. Identifying the active site in nitrogen-doped graphene for the VO2+/VO2(+) redox reaction.

    PubMed

    Jin, Jutao; Fu, Xiaogang; Liu, Qiao; Liu, Yanru; Wei, Zhiyang; Niu, Kexing; Zhang, Junyan

    2013-06-25

    Nitrogen-doped graphene sheets (NGS), synthesized by annealing graphite oxide (GO) with urea at 700-1050 °C, were studied as positive electrodes in a vanadium redox flow battery. The NGS, in particular annealed at 900 °C, exhibited excellent catalytic performance in terms of electron transfer (ET) resistance (4.74 ± 0.51 and 7.27 ± 0.42 Ω for the anodic process and cathodic process, respectively) and reversibility (ΔE = 100 mV, Ipa/Ipc = 1.38 at a scan rate of 50 mV s(-1)). Detailed research confirms that not the nitrogen doping level but the nitrogen type in the graphene sheets determines the catalytic activity. Among four types of nitrogen species doped into the graphene lattice including pyridinic-N, pyrrolic-N, quaternary nitrogen, and oxidic-N, quaternary nitrogen is verified as a catalytic active center for the [VO](2+)/[VO2](+) couple reaction. A mechanism is proposed to explain the electrocatalytic performance of NGS for the [VO](2+)/[VO2](+) couple reaction. The possible formation of a N-V transitional bonding state, which facilitates the ET between the outer electrode and reactant ions, is a key step for its high catalytic activity.

  17. Assessing ligand selectivity for uranium over vanadium ions to aid in the discovery of superior adsorbents for extraction of UO 2 2+ from seawater

    DOE PAGES

    Ivanov, Alexander S.; Bryantsev, Vyacheslav S.

    2016-06-06

    Uranium is used as the basic fuel for nuclear power plants, which generate significant amounts of electricity and have life cycle carbon emissions that are as low as renewable energy sources. However, the extraction of this valuable energy commodity from the ground remains controversial, mainly because of environmental and health impacts. Alternatively, seawater offers an enormous uranium resource that may be tapped at minimal environmental cost. Nowadays, amidoxime polymers are the most widely utilized sorbent materials for large-scale extraction of uranium from seawater, but they are not perfectly selective for uranyl, UO 2 2+. In particular, the competition between UOmore » 2 2+ and VO 2+/VO2+ cations poses a significant challenge to the effi-cient mining of UO 2 2+. Thus, screening and rational design of more selective ligands must be accomplished. One of the key components in achieving this goal is the establishment of computational techniques capable of assessing ligand selec-tivity trends. Here, we report an approach based on quantum chemical calculations that achieves high accuracy in repro-ducing experimental aqueous stability constants for VO 2+/VO 2+ complexes with ten different oxygen donor lig-ands. The predictive power of the developed computational protocol was demonstrated for amidoxime-type ligands, providing greater insights into new design strategies for the development of the next generation of adsorbents with high selectivity toward UO 2 2+over VO 2+/VO 2+ ions. Furthermore, the results of calculations suggest that alkylation of amidox-ime moieties present in poly(acrylamidoxime) sorbents can be a potential route to better discrimination between the uranyl and competing vanadium ions within seawater.« less

  18. Comparison of the 1.5 Mile Run Times at 7,200 Feet and Simulated 850 Feet in a Hyperoxic Room

    DTIC Science & Technology

    2012-03-01

    Maximal Oxygen Update ( VO2 max) Test ......................................... 7 Figure 3 - VO2 Max results for Male, Female and All Subjects. * p...0.001 between Male and Female VO2 ’s. ............................................................. 11 Figure 4 - VO2 Max vs Predicted VO2 Max at 850...and 7,200 Feet ................. 12 Figure 5 - Actual VO2 Max vs Predicted VO2 Max at ALT (7,200 Feet) ....... 13 Figure 6 - VO2 Max vs Predicted

  19. Physiological characteristics of America's Cup sailors.

    PubMed

    Bernardi, Marco; Quattrini, Filippo M; Rodio, Angelo; Fontana, Giuseppe; Madaffari, Andrea; Brugnoli, Marco; Marchetti, Marco

    2007-08-01

    The aim of this study was to assess the physiological profile of America's Cup grinders and mastmen, by measuring energy expenditure during sailing and assessing their aerobic and anaerobic fitness. The study focused on estimating the energy used during grinding activity, by measuring oxygen uptake (VO(2)) during sail setting in real sailing conditions. In the laboratory, using an arm-cranking ergometer, we measured VO(2peak) during an incremental maximal exercise test and total energy expended during the effort and recovery phases of an all-out test that simulated grinding activity, in six grinders and mastmen and ten sailors of the same crew. Total energy used during grinding corresponded to 45% (s = 9) and 51% (s = 5) of that used in the all-out test (234 kJ, s = 21.7) for tacks and gybes, respectively. In both grinding activity and the all-out test, VO(2) increased during and after the effort. The "VO(2) top value" was 53% (s = 8.6), 68% (s = 5.5), and 78% (s = 3.1) of VO(2peak) (4.7 l . min(-1), s = 0.43) in tacks, gybes, and the all-out test, respectively. During fast sequences of grinding activity, the "VO(2) top value" reached 65% (s = 7.1) VO(2peak) in tacks and 91% (s = 3.3) VO(2peak) in gybes. Our results suggest that grinders and mastmen are characterized by a high anaerobic capacity but their performance can be improved by powering aerobic fitness, to increase this energy contribution to all-out efforts and to guarantee fast recovery when grinding activity is repeated with short rest intervals.

  20. Formation kinetics and mechanism of metastable vacancy-dioxygen complex in neutron irradiated Czochralski silicon

    NASA Astrophysics Data System (ADS)

    Dong, Peng; Wang, Rong; Yu, Xuegong; Chen, Lin; Ma, Xiangyang; Yang, Deren

    2017-07-01

    We have quantitatively investigated the formation kinetics of metastable vacancy-dioxygen (VO2) complex in a structure of [VO + Oi], where a VO complex is trapped in a next-neighbor position to an interstitial oxygen atom (Oi). It is found that the VO annihilation is accompanied by the generation of metastable [VO + Oi] complex during annealing in the temperature range of 220-250 °C. The activation energy for [VO + Oi] generation appears at around 0.48 eV, which is much lower than the counterpart of stable VO2 complex. This indicates that the formation of [VO + Oi] complex originates from the reaction between VO and Oi. The ab initio calculations show that the formation energy of [VO + Oi] complex is larger than that of VO2 complex, which means that [VO + Oi] complex is thermodynamically unfavorable as compared to VO2 complex. However, the binding energy of [VO + Oi] complex is positive, indicating that [VO + Oi] complex is stable against decomposition of VO and Oi in silicon. It is believed that [VO + Oi] complex serves as the intermediate for VO to VO2 conversion.

  1. The 1201 superconductors Hg1-y(VO4)y(Ba, Sr)2CuO4-2y+δ: evidence for VO4 tetrahedra

    NASA Astrophysics Data System (ADS)

    Malo, S.; Hervieu, M.; Maignan, A.; Knížek, K.; Raveau, B.; Michel, C.

    1997-02-01

    A series of mercury based cuprates with nominal composition Hg1-yV(y)Ba2-xSrxCuO4+2y+δ has been prepared for x = 0, 0.25, 0.5, 0.75, 1 and 1.25. The actual solid solution limit from the EDS measurement is x = 1.1, y ranges from 0.2 to 0.35. The single crystal study coupled with high resolution electron microscopy shows for the first time the presence of VO4 tetrahedra replacing partly the mercury atoms according to the formulation Hg1-y(VO4)y(Ba,Sr)2 CuO4-2y+δ. The role of vanadium for the stabilisation of the structure and as a doping agent in the superconducting properties is discussed.

  2. Energy compensation after sprint- and high-intensity interval training.

    PubMed

    Schubert, Matthew M; Palumbo, Elyse; Seay, Rebekah F; Spain, Katie K; Clarke, Holly E

    2017-01-01

    Many individuals lose less weight than expected in response to exercise interventions when considering the increased energy expenditure of exercise (ExEE). This is due to energy compensation in response to ExEE, which may include increases in energy intake (EI) and decreases in non-exercise physical activity (NEPA). We examined the degree of energy compensation in healthy young men and women in response to interval training. Data were examined from a prior study in which 24 participants (mean age, BMI, & VO2max = 28 yrs, 27.7 kg•m-2, and 32 mL∙kg-1∙min-1) completed either 4 weeks of sprint-interval training or high-intensity interval training. Energy compensation was calculated from changes in body composition (air displacement plethysmography) and exercise energy expenditure was calculated from mean heart rate based on the heart rate-VO2 relationship. Differences between high (≥ 100%) and low (< 100%) levels of energy compensation were assessed. Linear regressions were utilized to determine associations between energy compensation and ΔVO2max, ΔEI, ΔNEPA, and Δresting metabolic rate. Very large individual differences in energy compensation were noted. In comparison to individuals with low levels of compensation, individuals with high levels of energy compensation gained fat mass, lost fat-free mass, and had lower change scores for VO2max and NEPA. Linear regression results indicated that lower levels of energy compensation were associated with increases in ΔVO2max (p < 0.001) and ΔNEPA (p < 0.001). Considerable variation exists in response to short-term, low dose interval training. In agreement with prior work, increases in ΔVO2max and ΔNEPA were associated with lower energy compensation. Future studies should focus on identifying if a dose-response relationship for energy compensation exists in response to interval training, and what underlying mechanisms and participant traits contribute to the large variation between individuals.

  3. Stress compensation for arbitrary curvature control in vanadium dioxide phase transition actuators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Kaichen, E-mail: dkc12@mails.tsinghua.edu.cn, E-mail: wuj@berkeley.edu; Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084

    2016-07-11

    Due to its thermally driven structural phase transition, vanadium dioxide (VO{sub 2}) has emerged as a promising material for micro/nano-actuators with superior volumetric work density, actuation amplitude, and repetition frequency. However, the high initial curvature of VO{sub 2} actuators severely obstructs the actuation performance and application. Here, we introduce a “seesaw” method of fabricating tri-layer cantilevers to compensate for the residual stress and realize nearly arbitrary curvature control of VO{sub 2} actuators. By simply adjusting the thicknesses of the individual layers, cantilevers with positive, zero, or negative curvatures can be engineered. The actuation amplitude can be decoupled from the curvaturemore » and controlled independently as well. Based on the experimentally measured residual stresses, we demonstrate sub-micron thick VO{sub 2} actuators with nearly zero final curvature and a high actuation amplitude simultaneously. This “seesaw” method can be further extended to the curvature engineering of other microelectromechanical system multi-layer structures where large stress-mismatch between layers are inevitable.« less

  4. Revealing mechanism responsible for structural reversibility of single-crystal VO 2 nanorods upon lithiation/delithiation

    DOE PAGES

    Liu, Qi; Tan, Guoqiang; Wang, Peng; ...

    2017-04-17

    A pure phase of VO 2(B) nanorods have been synthesized through an energy-efficient microwave hydrothermal reaction and used as cathode materials of lithium ion batteries, which exhibit promising specific capacity (e.g., 130 mA h g -1 even after 100 charge/discharge cycles) and rate capacity (e.g., ~130 mA h g -1 at a high current of 400 mA g -1). The excellent cyclability originates from the structural reversibility of VO 2(B) upon lithiation/delithiation that is confirmed by the in situ high-energy synchrotron X-ray diffraction (HEXRD) and in situ x-ray adsorption near-edge spectroscopy (XANES) of the VO 2 nanorods in operating batterymore » cells. As a result, the real-time results reveal that discharge forces lithium ions to insert firstly into the tunnels with the largest size along b direction followed by the second largest tunnels along c direction, which is completely reversible in the charge process.« less

  5. Revealing mechanism responsible for structural reversibility of single-crystal VO 2 nanorods upon lithiation/delithiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Qi; Tan, Guoqiang; Wang, Peng

    A pure phase of VO 2(B) nanorods have been synthesized through an energy-efficient microwave hydrothermal reaction and used as cathode materials of lithium ion batteries, which exhibit promising specific capacity (e.g., 130 mA h g -1 even after 100 charge/discharge cycles) and rate capacity (e.g., ~130 mA h g -1 at a high current of 400 mA g -1). The excellent cyclability originates from the structural reversibility of VO 2(B) upon lithiation/delithiation that is confirmed by the in situ high-energy synchrotron X-ray diffraction (HEXRD) and in situ x-ray adsorption near-edge spectroscopy (XANES) of the VO 2 nanorods in operating batterymore » cells. As a result, the real-time results reveal that discharge forces lithium ions to insert firstly into the tunnels with the largest size along b direction followed by the second largest tunnels along c direction, which is completely reversible in the charge process.« less

  6. Production and evolution of A-centers in n-type Si1-xGex

    NASA Astrophysics Data System (ADS)

    Sgourou, E. N.; Andrianakis, A.; Londos, C. A.; Chroneos, A.

    2013-03-01

    The vacancy-oxygen pair (VO or A-center) in n-type Si1-xGex crystals (x = 0, 0.025, 0.055) has been studied using infrared (IR) spectroscopy. It is determined that the VO production is suppressed in the case of n-type Si1-xGex as compared to Si. It is observed that the annealing temperature of the VO defect in Si1-xGex is substantially lower as compared to Si. The decay of the VO (830 cm-1) band, in the course of 20 min isochronal anneals, shows two stages: The onset of the first stage is at ˜180 °C and the decrease of the VO signal is accompanied in the spectra by the increase of the intensity of two bands at ˜834 and 839 cm-1. These bands appear in the spectra immediately after irradiation and were previously correlated with (VO-Ge) structures. The onset of the second stage occurs at ˜250 °C were the 830 cm-1 band of VO and the above two bands of (VO-Ge) decrease together in the spectra accompanied by the simultaneous growth of the 885 cm-1 band of the VO2 defect. Interestingly, the percentage of the VO pairs that are converted to VO2 defects is larger in the Si1-xGex samples with intermediate Ge content (x = 0.025) as compared with Si (x = 0) and with the high Ge content samples (x = 0.055). The results are discussed in view of the association of VO pairs with Ge.

  7. Investigation of the physical, optical, and photocatalytic properties of CeO2/Fe-doped InVO4 composite

    NASA Astrophysics Data System (ADS)

    Chaison, Jindaporn; Wetchakun, Khatcharin; Wetchakun, Natda

    2017-12-01

    The CeO2/Fe-doped InVO4 composites with various Fe concentrations (0.5, 1.0, 2.0, 5.0 and 6.0 mol%) was synthesized by homogeneous precipitation and hydrothermal methods. The as-synthesized samples were characterized by powder X-ray diffraction (XRD), Brunauer Emmett and Teller (BET)-specific surface area, field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and UV-visible diffuse reflectance spectroscopy (DRS). Fe-doping into InVO4 crystal induces the distortion of the crystalline structure, the transformation of InVO4 morphology, and the new energy subband level generation of Fe between the CB and VB edge of InVO4. The electron excitation from the VB to Fe orbitals results in the decreased band gap and the extended absorption of visible-light, and thus enhances its photocatalytic performance. Visible-light-driven photocatalytic degradation of Rhodamine B (RhB) dye in water was used to evaluate the photocatalytic performance of CeO2/Fe-doped InVO4 composites. The results revealed that there is an optimum Fe (5.0 mol %) doping level. The composite with the optimum doping level obtains high photocatalytic activity of CeO2/Fe-doped InVO4 composite compared to pure CeO2 and pure InVO4 host. The increase of photocatalytic activity of CeO2/Fe-doped InVO4 composite was ascribed to the surface area, crystal defect, and band gap energy. Moreover, the photocatalytic enhancement is also because iron ions act as a trapping site, which results in the higher separation efficiency of photogenerated electrons and holes pairs in the CeO2/InVO4 composite. The evaluation of radical scavengers confirmed that hydroxyl radical was the main active species during the photodegradation of RhB. These synergistic effects are responsible for the enhanced photocatalytic activity of CeO2/Fe-doped InVO4 composite. Furthermore, the possible enhanced photocatalytic mechanism of the CeO2/Fe-doped InVO4 composite was also proposed based on the calculation of band position.

  8. Wheelchair Shuttle Test for Assessing Aerobic Fitness in Youth With Spina Bifida: Validity and Reliability

    PubMed Central

    de Groot, Janke F.; Backx, Frank J.G.; Benner, Joyce; Kruitwagen, Cas L.J.J.; Takken, Tim

    2017-01-01

    Abstract Background Testing aerobic fitness in youth is important because of expected relationships with health. Objective The purpose of the study was to estimate the validity and reliability of the Shuttle Ride Test in youth who have spina bifida and use a wheelchair for mobility and sport. Design Ths study is a validity and reliability study. Methods The Shuttle Ride Test, Graded Wheelchair Propulsion Test, and skill-related fitness tests were administered to 33 participants for the validity study (age = 14.5 ± 3.1 y) and to 28 participants for the reliability study (age = 14.7 ± 3.3 y). Results No significant differences were found between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test for most cardiorespiratory responses. Correlations between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test were moderate to high (r = .55–.97). The variance in peak oxygen uptake (VO2peak) could be predicted for 77% of the participants by height, number of shuttles completed, and weight, with large prediction intervals. High correlations were found between number of shuttles completed and skill-related fitness tests (CI = .73 to −.92). Intraclass correlation coefficients were high (.77–.98), with a smallest detectable change of 1.5 for number of shuttles completed and with coefficients of variation of 6.2% and 6.4% for absolute VO2peak and relative VO2peak, respectively. Conclusions When measuring VO2peak directly by using a mobile gas analysis system, the Shuttle Ride Test is highly valid for testing VO2peak in youth who have spina bifida and use a wheelchair for mobility and sport. The outcome measure of number of shuttles represents aerobic fitness and is also highly correlated with both anaerobic performance and agility. It is not possible to predict VO2peak accurately by using the number of shuttles completed. Moreover, the Shuttle Ride Test is highly reliable in youth with spina bifida, with a good smallest detectable change for the number of shuttles completed. PMID:29029556

  9. Honeycomb-like S = 5/2 Spin–Lattices in Manganese(II) Vanadates

    DOE PAGES

    Sanjeewa, Liurukara. D.; McGuire, Michael A.; McMillen, Colin D.; ...

    2016-08-26

    We synthesized new complex manganese vanadate materials as high-quality single crystals in multi-millimeter lengths using a high-temperature, high-pressure hydrothermal method. We grew one compound, Mn 5(VO 4) 2(OH) 4, from Mn 2O 3 and V 2O 5 in 3 M CsOH at 580 °C and 1.5 kbar. Changing the mineralizer to 1 M CsOH/3MCsCl leads to the formation of another product, Mn 6O(VO 4) 2(OH). Both compounds were structurally characterized by single-crystal X-ray diffraction (Mn 5(VO 4) 2(OH) 4: C2/m, Z = 2, a = 9.6568(9) Å, b = 9.5627(9) Å, c = 5.4139(6) Å, β = 98.529(8)°; Mn 6O(VOmore » 4) 2(OH): P21/m, Z = 2, a = 8.9363(12) Å, b = 6.4678(8) Å, c = 10.4478(13) Å, β = 99.798(3)°), revealing interesting low-dimensional transition-metal features. Mn 5(VO 4) 2(OH) 4 possesses complex honeycomb-type Mn–O layers, built from edge-sharing [MnO 6] octahedra in the bc plane, with bridging vanadate groups connecting these layers along the a-axis. Mn 6O(VO 4) 2(OH) presents a more complicated structure with both octahedral [MnO 6] and trigonal bipyramidal [MnO 5] units. A different pattern of planar honeycomb sheets are formed by edge-shared [MnO6] octahedra, and these sublattices are connected through edge-shared dimers of [MnO 5] trigonal bipyramids to form corrugated sheets. Vanadate groups again condense the sheets into a three-dimensional framework. Infrared and Raman spectroscopies indicated the presence of OH groups and displayed characteristic Raman scattering due to vanadate groups. Furthermore, temperature-dependent magnetic studies indicated Curie–Weiss behavior above 100 K with significant anti-ferromagnetic coupling for both compounds, with further complex magnetic behavior at lower temperatures. The data indicate canted anti-ferromagnetic order below 57 K in Mn 5(VO 4) 2(OH) 4 and below 45 K in Mn 6O(VO 4) 2(OH). Members of another class of compounds, K 2M 3(VO 4) 2(OH) 2 (M = Mn, Co), also containing a honeycomb-type sublattice, were also synthesized to allow a comparison of the structural features across all three structure types and to demonstrate extension to other transition metals.« less

  10. VO 2 thin films synthesis for collaborators and various applications.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Raegan Lynn; Clem, Paul G.

    2016-11-01

    Vanadium dioxide (VO 2) is an attractive material for a variety of applications due to its metal-to-insulator transition (MIT) observed at modest temperatures. This transition takes VO 2 from its low temperature insulating monoclinic phase to a high temperature (above 68°C) metallic rutile phase. This transition gives rise to a change in resistivity up to 5 orders of magnitude and a change in complex refractive index (especially at IR wavelengths), which is of interest for radar circuit protection and tunable control of infrared signature. Recently, collaborations have been initiated between CINT scientists and external university programs. The Enhanced Surveillance fundsmore » help fund this work which enabled synthesis of VO 2 films for several collaborations with internal and external researchers.« less

  11. Efficient data replication for the delivery of high-quality video content over P2P VoD advertising networks

    NASA Astrophysics Data System (ADS)

    Ho, Chien-Peng; Yu, Jen-Yu; Lee, Suh-Yin

    2011-12-01

    Recent advances in modern television systems have had profound consequences for the scalability, stability, and quality of transmitted digital data signals. This is of particular significance for peer-to-peer (P2P) video-on-demand (VoD) related platforms, faced with an immediate and growing demand for reliable service delivery. In response to demands for high-quality video, the key objectives in the construction of the proposed framework were user satisfaction with perceived video quality and the effective utilization of available resources on P2P VoD networks. This study developed a peer-based promoter to support online advertising in P2P VoD networks based on an estimation of video distortion prior to the replication of data stream chunks. The proposed technology enables the recovery of lost video using replicated stream chunks in real time. Load balance is achieved by adjusting the replication level of each candidate group according to the degree-of-distortion, thereby enabling a significant reduction in server load and increased scalability in the P2P VoD system. This approach also promotes the use of advertising as an efficient tool for commercial promotion. Results indicate that the proposed system efficiently satisfies the given fault tolerances.

  12. Tracking of aerobic fitness from adolescence to mid-adulthood.

    PubMed

    Van Oort, C; Jackowski, S A; Eisenmann, J C; Sherar, L B; Bailey, D A; Mirwald, R; Baxter-Jones, A D G

    2013-01-01

    Although adults' aerobic fitness is known to be correlated with cardiovascular disease risk, the longitudinal relationship with adolescent aerobic fitness is poorly described. To longitudinally investigate the relationship between aerobic fitness during adolescence and adulthood. Participants (207 boys, 149 girls) aged 7-17 years performed annual measures of VO2peak. In adulthood (40 and 50 years), 78 individuals (59 males and 18 females) were reassessed. Serial height measurements were used to estimate age at peak height velocity (APHV). During adolescence, VO2peak was measured via a treadmill test to voluntary exhaustion; adult VO2peak was assessed using submaximal predictive tests. Correlations were tested using Spearman's rho. ANCOVA was used to assess adult VO2peak group differences based off APHV VO2peak groupings (low, average or high). When sexes were pooled, moderate tracking existed from 2 years prior to APHV to APHV and APHV to 2 years after APHV (0.46, p < 0.001 and 0.35, p < 0.01, respectively). Correlations between APHV and adult values were low when sexes were pooled (p < 0.05). Comparisons of aggregated sexes revealed the low adolescent VO2peak group had lower values in adulthood relative to other groups (p < 0.05). Aerobic fitness has a low tracking between APHV and adulthood.

  13. Sex differences and the effects of modified combat regulations on endurance capacity in judo athletes: A meta-analytic approach.

    PubMed

    Sterkowicz-Przybycień, Katarzyna; Fukuda, David H

    2016-06-01

    Judo requires endurance capacity to recover from its high-intensity intermittent actions. This systematic review aimed to evaluate VO2max and the anaerobic threshold in competitive male and female judo athletes. Twelve eligible studies were chosen for quantitative meta-analysis, including results for 188 male and 159 female athletes. Combined values were calculated and compared by gender prior to and following altered combat regulations in 2003. No significant differences in VO2max were noted following the rule changes, but female athletes' values increased to a level comparable to those reported in male athletes prior to the alterations. VO2max in male judo athletes was higher (54.8±1.9 ml·kg -1 ·min -1 ) than in female athletes (48.7±2.2 ml·kg -1 ·min -1 ). The effect size of gender was large (d = 1.30) for VO2max and negligible for the anaerobic threshold. Sexual dimorphism exists in VO2max of judo athletes and changes in combat duration did not affect these differences.

  14. Peak Exercise Oxygen Uptake Predicts Recurrent Admissions in Heart Failure With Preserved Ejection Fraction.

    PubMed

    Palau, Patricia; Domínguez, Eloy; Núñez, Eduardo; Ramón, José María; López, Laura; Melero, Joana; Sanchis, Juan; Bellver, Alejandro; Santas, Enrique; Bayes-Genis, Antoni; Chorro, Francisco J; Núñez, Julio

    2018-04-01

    Heart failure with preserved ejection fraction (HFpEF) is a highly prevalent syndrome with an elevated risk of morbidity and mortality. To date, there is scarce evidence on the role of peak exercise oxygen uptake (peak VO 2 ) for predicting the morbidity burden in HFpEF. We sought to evaluate the association between peak VO 2 and the risk of recurrent hospitalizations in patients with HFpEF. A total of 74 stable symptomatic patients with HFpEF underwent a cardiopulmonary exercise test between June 2012 and May 2016. A negative binomial regression method was used to determine the association between the percentage of predicted peak VO 2 (pp-peak VO 2 ) and recurrent hospitalizations. Risk estimates are reported as incidence rate ratios. The mean age was 72.5 ± 9.1 years, 53% were women, and all patients were in New York Heart Association functional class II to III. Mean peak VO 2 and median pp-peak VO 2 were 10 ± 2.8mL/min/kg and 60% (range, 47-67), respectively. During a median follow-up of 276 days [interquartile range, 153-1231], 84 all-cause hospitalizations in 31 patients (41.9%) were registered. A total of 15 (20.3%) deaths were also recorded. On multivariate analysis, accounting for mortality as a terminal event, pp-peak VO 2 was independently and linearly associated with the risk of recurrent admission. Thus, and modeled as continuous, a 10% decrease of pp-peak VO 2 increased the risk of recurrent hospitalizations by 32% (IRR, 1.32; 95%CI, 1.03-1.68; P = .028). In symptomatic elderly patients with HFpEF, pp-peak VO 2 predicts all-cause recurrent admission. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  15. High beam quality of a Q-switched 2-µm Tm,Ho:LuVO4 laser

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yang, Xining; Shen, Yingjie; Li, Linjun; Zhou, Long; Yang, Yuqiang; Bai, Yunfeng; Xie, Wenqiang; Ye, Guangchao; Yu, Xiaoyang

    2018-05-01

    A diode-end-pumped 2.05-µm Q-switched Tm,Ho:LuVO4 laser is reported in this paper. The cryogenic Tm3+ (5.0 at.%),Ho3+ (0.5 at.%):LuVO4 crystal was pumped by an 800-nm laser diode. At a pulse repetition frequency of 10 kHz, the maximum average output power of 3.77 W was achieved at 77 K when an incident pump power of 14.7 W was used. The slope efficiency and optical-optical conversion efficiency were 28.3 and 25.6%, respectively. The maximum per pulse energy was 2.54 mJ for a pulse duration of 69.9 ns. The beam quality factor Mx 2 was approximately 1.17 and My 2 was approximately 1.01 for the Tm,Ho:LuVO4 laser.

  16. Ultrafast Silicon-based Modulators using Optical Switching of Vanadium Dioxide

    DTIC Science & Technology

    2014-12-04

    demonstrated by using photothermal heating to induce the VO2 semiconductor-to- metal phase transition and modulate the transmitted optical signal...speeds. By utilizing the sub-picosecond semiconductor-to- metal transition (SMT) in VO2 as the active switching mechanism that enables direct... metallic phases. The steep slope, high contrast, and relatively narrow hysteresis exhibited by these reflectivity measurements indicate the high quality

  17. Long-term effects of high-intensity interval training in heart transplant recipients: A 5-year follow-up study of a randomized controlled trial.

    PubMed

    Yardley, Marianne; Gullestad, Lars; Bendz, Bjørn; Bjørkelund, Elisabeth; Rolid, Katrine; Arora, Satish; Nytrøen, Kari

    2017-01-01

    Previous studies have demonstrated that high-intensity interval training (HIT) is superior to moderate-continuous exercise in general and in cardiovascular diseases. Recently, we also found HIT safe and efficient after heart transplantation (HTx). This study reports the 5-year long-term effects. Forty-one HTx patients who had completed the previous 12-month randomized controlled trial, comparing HIT intervention with usual care, were eligible. In particular, we measured VO 2peak , muscular capacity, intravascular ultrasound, and questionnaires measuring physical and mental health. The baseline mean±SD values were as follows: age; 49.1±16.5 years, men; 68%, time since HTx: 4.1±2.2 years. Within the HIT group, initial VO 2peak increased significantly from 27.7±5.7 to 31.2±5.3 mL/kg/min. However, during the next 4 years, VO 2peak decreased to 26.0±6.2 mL/kg/min. The control group showed slightly decreasing VO 2peak values during the entire 5-year period. The HIT group reported significantly less anxiety symptoms, but there were no long-term differences in VO 2peak , muscular capacity, or cardiac allograft vasculopathy between the groups. The similar VO 2peak values correspond to our findings of similar everyday activity. Our findings suggest that intermittent periods of HIT may be necessary to maintain the initial benefits gained from the intervention. However, HIT probably reduces the burden of anxiety, which is a frequent health issue following HTx. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Relation of oxygen uptake to work rate in prepubertal healthy children - reference for VO2/W-slope and effect on cardiorespiratory fitness assessment.

    PubMed

    Tompuri, Tuomo; Lintu, Niina; Laitinen, Tomi; Lakka, Timo A

    2017-08-09

    Exercise testing by cycle ergometer allows to observe the interaction between oxygen uptake (VO 2 ) and workload (W), and VO 2 /W-slope can be used as a diagnostic tool. Respectively, peak oxygen uptake (VO 2 PEAK ) can be estimated by maximal workload. We aim to determine reference for VO 2 /W-slope among prepubertal children and define agreement between estimated and measured VO 2 PEAK . A total of 38 prepubertal children (20 girls) performed a maximal cycle ergometer test with respiratory gas analysis. VO 2 /W-slopes were computed using linear regression. Agreement analysis by Bland and Altman for estimated and measured VO 2 PEAK was carried out including limits of agreement (LA). Determinants for VO 2 /W-slopes and estimation bias were defined. VO2/W-slope was in both girls and boys ≥9·4 and did not change with exercise level, but the oxygen cost of exercise was higher among physically more active children. Estimated VO 2 PEAK had 6·4% coefficient of variation, and LA varied from 13% underestimation to 13% overestimation. Bias had a trend towards underestimation along lean mass proportional VO 2 PEAK . The primary determinant for estimation bias was VO2/W-slope (β = -0·65; P<0·001). The reference values for VO 2 /W-slope among healthy prepubertal children were similar to those published for adults and among adolescents. Estimated and measured VO 2 PEAK should not be considered to be interchangeable because of the variation in the relationship between VO 2 and W. On other hand, variation in the relationship between VO 2 and W enables that VO 2 /W-slope can be used as a diagnostic tool. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  19. How Is Pulmonary Function and Exercise Tolerance Affected in Patients With AIS Who Have Undergone Spinal Fusion?

    PubMed

    Jeans, Kelly A; Lovejoy, John F; Karol, Lori A; McClung, Anna M

    2017-11-01

    Prospectively enrolled AIS patients who underwent spinal fusion, with 2 year follow-up. To evaluate the cardiovascular fitness and activity level in patients with AIS pre- and post-spinal fusion and to determine if initial curve magnitude or pulmonary function is predictive of exercise capacity. Researchers have tried to link pulmonary function testing (PFT) to exercise capacity; the results are mixed. Some report no improvement in PFTs or aerobic activity after surgical correction, and PFT measures were not predictive of exercise capacity. Conflicting results have shown Vo 2max results to fall within normal range in AIS patients while PFTs show minimal impairment. AIS patients underwent PFT and oxygen consumption (VO 2 ) testing during a submaximal graded exercise test (GXT) pre- and post-spinal fusion. Vo 2max was predicted in those patients who completed the test to 85% of maximal heart rate. Pre- to postoperative changes were assessed and then compared to age-matched control subjects. Correlations between Vo 2max and curve severity, pulmonary function, and activity level were assessed. Thirty-seven patients participated. Vo 2max was predicted in 23 patients pre- and postoperation. There was a significant reduction in Vo 2max postfusion (39.5 ± 6.5 mL/kg/min vs 42.1 ± 8.1 mL/kg/min, p = .033); however, compared with controls (40.5 ± 6.5 mL/kg/min), all data were within the normal range (p > .05). AIS patients reporting high activity had significantly greater Vo 2max than those reporting low activity both pre and postoperatively, but this difference only met statistical significance preop (p < .05). Curve magnitude and PFT measures were not found to correlate with Vo 2max (p > .05). Vo 2max in patients with AIS is within normal range both pre- and postfusion. Pulmonary limitations are accommodated for with a slightly increased breathing rate and a slightly reduced overall workload. Activity level rather than curve severity affects Vo 2max outcomes following fusion in AIS. Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  20. Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device.

    PubMed

    Takala, J; Keinänen, O; Väisänen, P; Kari, A

    1989-10-01

    The performance of a new gas exchange monitor was assessed both in laboratory simulation and in ICU patients. Laboratory simulation using N2 and CO2 injections resulted in a mean error of 2 +/- 2% in CO2 production (VCO2) and 4 +/- 4% in oxygen consumption (VO2) in respirator measurements (n = 55) and in a mean error of 3 +/- 2% in VCO2 and 4 +/- 2% in VO2 in canopy measurements (n = 25). The mean error in RQ during ethanol burning was 2 +/- 2% in respirator measurements (n = 45) and 1 +/- 1% in canopy measurements. FIO2 had little effect on the accuracy of VCO2, whereas the accuracy on high rates of VO2 (VO2 = 400 ml/min) was reduced, when FIO2 increased: the error ranged from 1 +/- 1% to 6 +/- 1%, except at VO2 400 ml/min during FIO2 0.8, where the error was 16 +/- 3%. Neither peak airway pressure (+13 to +63 cm H2O) nor PEEP (0 to +20 cm H2O) had an effect on the accuracy. The highest level of minute ventilation studied (22.5 L/min) reduced the accuracy slightly (mean error of VCO2 4 +/- 1% and VO2 7 +/- 2%). In patients during controlled mechanical ventilation, increasing FIO2 from 0.4 to 0.6 had no effect on the results. VO2 was consistently higher by gas exchange than by the Fick principle: 16 +/- 9% during controlled ventilation (n = 20), 21 +/- 8% on synchronized intermittent mandatory ventilation (n = 10) and 25 +/- 8% during spontaneous breathing. We conclude that the device proved to be accurate for gas exchange measurements in the ICU.

  1. BiVO4 Photoanode with Exposed (040) Facets for Enhanced Photoelectrochemical Performance

    NASA Astrophysics Data System (ADS)

    Xia, Ligang; Li, Jinhua; Bai, Jing; Li, Linsen; Chen, Shuai; Zhou, Baoxue

    2018-03-01

    A BiVO4 photoanode with exposed (040) facets was prepared to enhance its photoelectrochemical performance. The exposure of the (040) crystal planes of the BiVO4 film was induced by adding NaCl to the precursor solution. The as-prepared BiVO4 photoanode exhibits higher solar-light absorption and charge-separation efficiency compared to those of an anode prepared without adding NaCl. To our knowledge, the photocurrent density (1.26 mA cm-2 at 1.23 V vs. RHE) of as-prepared BiVO4 photoanode is the highest according to the reports for bare BiVO4 films under simulated AM1.5G solar light, and the incident photon-to-current conversion efficiency is above 35% at 400 nm. The photoelectrochemical (PEC) water-splitting performance was also dramatically improved with a hydrogen evolution rate of 9.11 μmol cm-2 h-1, which is five times compared with the BiVO4 photoanode prepared without NaCl (1.82 μmol cm-2 h-1). Intensity-modulated photocurrent spectroscopy and transient photocurrent measurements show a higher charge-carrier-transfer rate for this photoanode. These results demonstrate a promising approach for the development of high-performance BiVO4 photoanodes which can be used for efficient PEC water splitting and degradation of organic pollutants. [Figure not available: see fulltext.

  2. Superior exercise performance in lifelong Tibetan residents of 4,400 m compared with Tibetan residents of 3,658 m.

    PubMed

    Curran, L S; Zhuang, J; Droma, T; Moore, L G

    1998-01-01

    Few environments challenge human populations more than high altitude, since the accompanying low oxygen pressures (hypoxia) are pervasive and impervious to cultural modification. Work capacity is an important factor in a population's ability to thrive in such an environment. The performance of work or exercise is a measure of the integrated functioning of the O2 transport system, with maximal O2 uptake (.VO2max) a convenient index of that function. Hypoxia limits the ability to transport oxygen: maximal O2 uptake decreases with ascent to high altitude, and years of high altitude residence do not restore sea level .VO2max values. Since Tibetans live and work at some of the highest altitudes in the world, their ability to exercise at very high altitude (>4,000 m) may define the limits of human adaptation to hypoxia. We transported 20 Tibetan lifelong residents of > or =4,400 m down to 3,658 m in order to compare them with 16 previously studied Tibetan residents of Lhasa (3,658 m). The two groups of Tibetans were matched for age, weight, and height. All studies were performed in Lhasa within 3 days of the 4,400 m Tibetans' arrival. Standard test protocol and criteria were used for attaining .VO2max on a Monark bicycle ergometer, while measuring oxygen uptake (.VO2, ml/kg - min STPD), heart rate (bpm), minute ventilation (VE, 1/min BTPS), and arterial oxygen saturation (SaO2, %). The 4,400 m compared with 3,658 m residents had, at maximal effort, similar .VO2 (48.5 +/- 1.2 vs. 51.2 +/- 1.4 ml/kg - min, P = NS), higher workload attained (211 +/- 6 vs. 177 +/- 7 watts, P < 0.01), lower heart rate(176 +/- 2 vs. 191 +/- 2 bpm, P < 0.01), lower ventilation (127 +/- 5 vs. 149 +/- 5 l/min BTPS, P < 0.01), and similar SaO2(81.9 +/- 1.0 vs. 83.7 +/- 1.2%, P = NS). Furthermore, over the range of submaximal workloads, 4,400 m compared with 3,658 m Tibetans had lower .VO2 (P < 0.01), lower heart rates (P < 0.01), and lower ventilation (P < 0.01) and SaO2 (P < 0.05). We conclude that Tibetans living at 4,400 m compared with those residing at 3,658 m achieve greater work performance for a given .VO2 at submaximal and maximal workloads with less cardiorespiratory effort.

  3. Roles of Bi, M and VO{sub 4} tetrahedron in photocatalytic properties of novel Bi{sub 0.5}M{sub 0.5}VO{sub 4} (M=La, Eu, Sm and Y) solid solutions for overall water splitting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu Hui; Research Center for Combustion and Environment Technology, Shanghai Jiao Tong University, shanghai 200240; Faculty of Engineering Sciences, Kyushu University, Fukuoka 816-8580

    2012-02-15

    Novel Bi{sub 0.5}M{sub 0.5}VO{sub 4} (BMV; M=La, Eu, Sm and Y) solid solutions were prepared and studied in this paper. All the samples were proved to produce H{sub 2} and O{sub 2} simultaneously from pure water under the irradiation of UV light. M-O bond lengths were proved to increase with M cations by refining cell parameters and atomic positions. Besides, band gaps, energy gaps and photocatalytic activities of BMV also changed with M cations. Both of M-O and V-O bond lengths were suggested to account for this phenomenon. Inactive A{sub 0.5}Y{sub 0.5}VO{sub 4} (A=La, Ce) for water splitting proved incorporationmore » of Bi rather than distortion of VO{sub 4} tetrahedron was a critical factor for improving efficiency of overall water splitting by facilitating the generation of electron and hole with lighter effective masses. Replacement of Bi by M cations not only gave indirect effect on band structure but also raised position of conduction band minimum to meet requirement of H{sub 2} production. - Graphical abstract: Novel Bi{sub 0.5}M{sub 0.5}VO{sub 4} (M=La, Eu, Sm and Y) solid solutions showed the high and stable photocatalytic activities for overall water splitting with their crystal radii of M elements. Highlights: Black-Right-Pointing-Pointer BMV solid solutions were novel highly efficient V-based photocatalysts for overall water splitting. Black-Right-Pointing-Pointer Photocatalytic activity of BMV solid solution related to the effective ionic radii of M cations. Black-Right-Pointing-Pointer Incorporation of Bi is one of key factors for the highly efficient activity of BMV solid solution. Black-Right-Pointing-Pointer Incorporation of Y is dispensable for H{sub 2} production.« less

  4. Pulsed laser-deposited VO2 thin films on Pt layers

    NASA Astrophysics Data System (ADS)

    Sakai, Joe; Zaghrioui, Mustapha; Ta Phuoc, Vinh; Roger, Sylvain; Autret-Lambert, Cécile; Okimura, Kunio

    2013-03-01

    VO2 films were deposited on Pt (111)/TiO2/SiO2/Si (001) substrates by means of a pulsed laser deposition technique. An x-ray diffraction peak at 2θ = 39.9° was deconvoluted into two pseudo-Voigt profiles of Pt (111) and VOx-originated components. The VOx diffraction peak was more obvious in a VOx/Pt (111)/Al2O3 (0001) sample, having a narrower width compared with a VO2/Al2O3 (0001) sample. Temperature-controlled Raman spectroscopy for the VOx/Pt/TiO2/SiO2/Si sample has revealed the monoclinic VO2 phase at low temperature and the structural phase transition at about 72 °C in a heating process. The electronic conductive nature at the high temperature phase was confirmed by near normal incidence infrared reflectivity measurements. Out-of-plane current-voltage characteristics showed an electric field-induced resistance switching at a voltage as low as 0.2 V for a 50 nm-thick film. A survey of present and previous results suggests an experimental law that the transition voltage of VO2 is proportional to the square root of the electrodes distance.

  5. Relationship between oxygen uptake slow component and surface EMG during heavy exercise in humans: influence of pedal rate.

    PubMed

    Vercruyssen, Fabrice; Missenard, Olivier; Brisswalter, Jeanick

    2009-08-01

    The aim of this study was to test the hypothesis that extreme pedal rates contributed to the slow component of oxygen uptake (VO(2) SC) in association with changes in surface electromyographic (sEMG) during heavy-cycle exercise. Eight male trained cyclists performed two square-wave transitions at 50 and 110 rpm at a work rate that would elicit a VO(2) corresponding to 50% of the difference between peak VO(2) and the ventilatory threshold. Pulmonary gas exchange was measured breath-by-breath and sEMG was obtained from the vastus lateralis and medialis muscles. Integrated EMG flow (QiEMG) and mean power frequency (MPF) were computed. The relative amplitude of the VO(2) SC was significantly higher during the 110-rpm bout (556+/-186 ml min(-1), P<0.05) with compared to the 50-rpm bout (372+/-227 ml min(-1)). QiEMG values increased throughout exercise only during the 110-rpm bout and were associated with the greater amplitude of the VO(2) SC observed for this condition (P<0.05). MPF values remained relatively constant whatever the cycle bout. These findings indicated a VO(2) SC at the two pedal rates but the association with sEMG responses was observed only at high pedal rate. Possible changes in motor units recruitment pattern, muscle energy turnover and muscle temperature have been suggested to explain the different VO(2) SC to heavy pedal rate bouts.

  6. VO2 estimation using 6-axis motion sensor with sports activity classification.

    PubMed

    Nagata, Takashi; Nakamura, Naoteru; Miyatake, Masato; Yuuki, Akira; Yomo, Hiroyuki; Kawabata, Takashi; Hara, Shinsuke

    2016-08-01

    In this paper, we focus on oxygen consumption (VO2) estimation using 6-axis motion sensor (3-axis accelerometer and 3-axis gyroscope) for people playing sports with diverse intensities. The VO2 estimated with a small motion sensor can be used to calculate the energy expenditure, however, its accuracy depends on the intensities of various types of activities. In order to achieve high accuracy over a wide range of intensities, we employ an estimation framework that first classifies activities with a simple machine-learning based classification algorithm. We prepare different coefficients of linear regression model for different types of activities, which are determined with training data obtained by experiments. The best-suited model is used for each type of activity when VO2 is estimated. The accuracy of the employed framework depends on the trade-off between the degradation due to classification errors and improvement brought by applying separate, optimum model to VO2 estimation. Taking this trade-off into account, we evaluate the accuracy of the employed estimation framework by using a set of experimental data consisting of VO2 and motion data of people with a wide range of intensities of exercises, which were measured by a VO2 meter and motion sensor, respectively. Our numerical results show that the employed framework can improve the estimation accuracy in comparison to a reference method that uses a common regression model for all types of activities.

  7. Ab Initio Metadynamics Study of the VO2+/VO2+ Redox Reaction Mechanism at the Graphite Edge/Water Interface.

    PubMed

    Jiang, Zhen; Klyukin, Konstantin; Alexandrov, Vitaly

    2018-06-20

    Redox flow batteries (RFBs) are promising electrochemical energy storage systems, for which development is impeded by a poor understanding of redox reactions occurring at electrode/electrolyte interfaces. Even for the conventional all-vanadium RFB chemistry employing V 2+ /V 3+ and VO 2 + /VO 2+ couples, there is still no consensus about the reaction mechanism, electrode active sites, and rate-determining step. Herein, we perform Car-Parrinello molecular dynamics-based metadynamics simulations to unravel the mechanism of the VO 2 + /VO 2+ redox reaction in water at the oxygen-functionalized graphite (112̅0) edge surface serving as a representative carbon-based electrode. Our results suggest that during the battery discharge aqueous VO 2 + /VO 2+ species adsorb at the surface C-O groups as inner-sphere complexes, exhibiting faster adsorption/desorption kinetics than V 2+ /V 3+ , at least at low vanadium concentrations considered in our study. We find that this is because (i) VO 2 + /VO 2+ conversion does not involve the slow transfer of an oxygen atom, (ii) protonation of VO 2 + is spontaneous and coupled to interfacial electron transfer in acidic conditions to enable VO 2+ formation, and (iii) V 3+ found to be strongly bound to oxygen groups of the graphite surface features unfavorable desorption kinetics. In contrast, the reverse process taking place upon charging is expected to be more sluggish for the VO 2 + /VO 2+ redox couple because of both unfavorable deprotonation of the VO 2+ water ligands and adsorption/desorption kinetics.

  8. Preparation and modification of VO2 thin film on R-sapphire substrate by rapid thermal process

    NASA Astrophysics Data System (ADS)

    Zhu, Nai-Wei; Hu, Ming; Xia, Xiao-Xu; Wei, Xiao-Ying; Liang, Ji-Ran

    2014-04-01

    The VO2 thin film with high performance of metal-insulator transition (MIT) is prepared on R-sapphire substrate for the first time by magnetron sputtering with rapid thermal process (RTP). The electrical characteristic and THz transmittance of MIT in VO2 film are studied by four-point probe method and THz time domain spectrum (THz-TDS). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and search engine marketing (SEM) are employed to analyze the crystalline structure, valence state, surface morphology of the film. Results indicate that the properties of VO2 film which is oxidized from the metal vanadium film in oxygen atmosphere are improved with a follow-up RTP modification in nitrogen atmosphere. The crystallization and components of VO2 film are improved and the film becomes compact and uniform. A better phase transition performance is shown that the resistance changes nearly 3 orders of magnitude with a 2-°C hysteresis width and the THz transmittances are reduced by 64% and 60% in thermal and optical excitation respectively.

  9. Validation of a single-stage fixed-rate step test for the prediction of maximal oxygen uptake in healthy adults.

    PubMed

    Hansen, Dominique; Jacobs, Nele; Thijs, Herbert; Dendale, Paul; Claes, Neree

    2016-09-01

    Healthcare professionals with limited access to ergospirometry remain in need of valid and simple submaximal exercise tests to predict maximal oxygen uptake (VO2max ). Despite previous validation studies concerning fixed-rate step tests, accurate equations for the estimation of VO2max remain to be formulated from a large sample of healthy adults between age 18-75 years (n > 100). The aim of this study was to develop a valid equation to estimate VO2max from a fixed-rate step test in a larger sample of healthy adults. A maximal ergospirometry test, with assessment of cardiopulmonary parameters and VO2max , and a 5-min fixed-rate single-stage step test were executed in 112 healthy adults (age 18-75 years). During the step test and subsequent recovery, heart rate was monitored continuously. By linear regression analysis, an equation to predict VO2max from the step test was formulated. This equation was assessed for level of agreement by displaying Bland-Altman plots and calculation of intraclass correlations with measured VO2max . Validity further was assessed by employing a Jackknife procedure. The linear regression analysis generated the following equation to predict VO2max (l min(-1) ) from the step test: 0·054(BMI)+0·612(gender)+3·359(body height in m)+0·019(fitness index)-0·012(HRmax)-0·011(age)-3·475. This equation explained 78% of the variance in measured VO2max (F = 66·15, P<0·001). The level of agreement and intraclass correlation was high (ICC = 0·94, P<0·001) between measured and predicted VO2max . From this study, a valid fixed-rate single-stage step test equation has been developed to estimate VO2max in healthy adults. This tool could be employed by healthcare professionals with limited access to ergospirometry. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  10. Porous silicon-VO{sub 2} based hybrids as possible optical temperature sensor: Wavelength-dependent optical switching from visible to near-infrared range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antunez, E. E.; Salazar-Kuri, U.; Estevez, J. O.

    Morphological properties of thermochromic VO{sub 2}—porous silicon based hybrids reveal the growth of well-crystalized nanometer-scale features of VO{sub 2} as compared with typical submicron granular structure obtained in thin films deposited on flat substrates. Structural characterization performed as a function of temperature via grazing incidence X-ray diffraction and micro-Raman demonstrate reversible semiconductor-metal transition of the hybrid, changing from a low-temperature monoclinic VO{sub 2}(M) to a high-temperature tetragonal rutile VO{sub 2}(R) crystalline structure, coupled with a decrease in phase transition temperature. Effective optical response studied in terms of red/blue shift of the reflectance spectra results in a wavelength-dependent optical switching withmore » temperature. As compared to VO{sub 2} film over crystalline silicon substrate, the hybrid structure is found to demonstrate up to 3-fold increase in the change of reflectivity with temperature, an enlarged hysteresis loop and a wider operational window for its potential application as an optical temperature sensor. Such silicon based hybrids represent an exciting class of functional materials to display thermally triggered optical switching culminated by the characteristics of each of the constituent blocks as well as device compatibility with standard integrated circuit technology.« less

  11. Comprehensive studies of interfacial strain and oxygen vacancy on metal-insulator transition of VO2 film

    NASA Astrophysics Data System (ADS)

    Fan, L. L.; Chen, S.; Liao, G. M.; Chen, Y. L.; Ren, H.; Zou, C. W.

    2016-06-01

    As a typical strong correlation material, vanadium dioxide (VO2) has attracted wide interest due to its particular metal-insulator transition (MIT) property. However, the relatively high critical temperature (T c) of ~68 °C seriously hinders its practical applications. Thus modulating the phase transition process and decreasing the T c close to room temperature have been hot topics for VO2 study. In the current work, we conducted a multi-approach strategy to control the phase transition of VO2 films, including the interfacial tensile/compressive strain and oxygen vacancies. A synchrotron radiation reciprocal space mapping technique was used to directly record the interfacial strain evolution and variations of lattice parameters. The effects of interfacial strain and oxygen vacancies in the MIT process were systematically investigated based on band structure and d-orbital electron occupation. It was suggested that the MIT behavior can be modulated through the combined effects of the interfacial strain and oxygen vacancies, achieving the distinct phase transition close to room temperature. The current findings not only provide better understanding for strain engineering and oxygen vacancies controlling phase transition behavior, but also supply a combined way to control the phase transition of VO2 film, which is essential for VO2 film based device applications in the future.

  12. Comprehensive studies of interfacial strain and oxygen vacancy on metal-insulator transition of VO2 film.

    PubMed

    Fan, L L; Chen, S; Liao, G M; Chen, Y L; Ren, H; Zou, C W

    2016-06-29

    As a typical strong correlation material, vanadium dioxide (VO2) has attracted wide interest due to its particular metal-insulator transition (MIT) property. However, the relatively high critical temperature (T c) of ~68 °C seriously hinders its practical applications. Thus modulating the phase transition process and decreasing the T c close to room temperature have been hot topics for VO2 study. In the current work, we conducted a multi-approach strategy to control the phase transition of VO2 films, including the interfacial tensile/compressive strain and oxygen vacancies. A synchrotron radiation reciprocal space mapping technique was used to directly record the interfacial strain evolution and variations of lattice parameters. The effects of interfacial strain and oxygen vacancies in the MIT process were systematically investigated based on band structure and d-orbital electron occupation. It was suggested that the MIT behavior can be modulated through the combined effects of the interfacial strain and oxygen vacancies, achieving the distinct phase transition close to room temperature. The current findings not only provide better understanding for strain engineering and oxygen vacancies controlling phase transition behavior, but also supply a combined way to control the phase transition of VO2 film, which is essential for VO2 film based device applications in the future.

  13. Aerobic Capacity Following Long Duration International Spaces Station (ISS) Missions: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Moore, Alan D.; Lee, S.M.C.; Everett, M.E.; Guined, J.R.; Knudsen, P.

    2010-01-01

    Maximum oxygen uptake (VO2max) is reduced immediately following space flights lasting <15 d, but has not been measured following long-duration missions. The purpose of this study is to measure VO2max and maximum work rate (WRmax) data from astronauts following ISS flights (91 to 188 d). Methods: Five astronauts [3 M, 2 F: 47+/-6 yr, 174+/-6 cm, 71.9+/-10.9 kg (mean +/- SD)] have participated in the study. Subjects performed upright cycle exercise tests to symptom-limited maximum. An initial test was done approx.270 d before flight to establish work rates for subsequent tests. Subsequent tests, conducted approx.45 d before flight and repeated on the first or second day (R+1/2) and at approx.10 d (R+10) following landing, consisted of 3 5 min stages designed to elicit 25%, 50%, and 75% of preflight VO2max, followed by 25 W(dot)/min increases. VO2, WR, and heart rate (HR) were measured using the ISS Portable Pulmonary Function System [Damec, Odense, DK]. Descriptive statistics are reported. Results: On R+1/2 mean VO2max decreased compared to preflight (Pre: 2.98+/-0.99, R+1/2: 2.63+/-0.56 L(dot)/min); 4 of 5 subjects demonstrated a loss of > 6%. WRmax also decreased on R+1/2 compared to preflight (Pre: 245+/-69, R+1/2: 210+/-45 W). On R+10, VO2max was 2.86+/-0.62 L(dot)/min, with 2 subjects still demonstrating a loss of > 6% from preflight. WRmax on R+10 was 240+/-49 W. HRmax did not change from pre to post-flight. Conclusions: These preliminary results, from the first 5 of 12 planned subjects of an ongoing ISS study, suggest that the majority of astronauts will experience a decrease in VO2max after long-duration space-flight. Interestingly, the two astronauts with the highest preflight VO2max had the greatest loss on R+1/2, and the astronaut with the lowest preflight VO2max increased by 13%. Thus, maintenance of VO2max may be more difficult in astronauts who have a high aerobic capacity, perhaps requiring more intense in-flight exercise countermeasure prescriptions.

  14. Aqueous citrato-oxovanadate(IV) precursor solutions for VO2: synthesis, spectroscopic investigation and thermal analysis.

    PubMed

    Peys, Nick; Adriaensens, Peter; Van Doorslaer, Sabine; Gielis, Sven; Peeters, Ellen; De Dobbelaere, Christopher; De Gendt, Stefan; Hardy, An; Van Bael, Marlies K

    2014-09-07

    An aqueous precursor solution, containing citrato-VO(2+) complexes, is synthesized for the formation of monoclinic VO2. With regard to the decomposition of the VO(2+) complexes towards vanadium oxide formation, it is important to gain insights into the chemical structure and transformations of the precursor during synthesis and thermal treatment. Hence, the conversion of the cyclic [V4O12](4-) ion to the VO(2+) ion in aqueous solution, using oxalic acid as an acidifier and a reducing agent, is studied by (51)Vanadium nuclear magnetic resonance spectroscopy. The citrate complexation of this VO(2+) ion and the differentiation between a solution containing citrato-oxalato-VO(2+) and citrato-VO(2+) complexes are studied by electron paramagnetic resonance and Fourier transform infra-red spectroscopy. In both solutions, the VO(2+) containing complex is mononuclear and has a distorted octahedral geometry with a fourfold R-CO2(-) ligation at the equatorial positions and likely a fifth R-CO2(-) ligation at the axial position. Small differences in the thermal decomposition pathway between the gel containing citrato-oxalato-VO(2+) complexes and the oxalate-free gel containing citrato-VO(2+) complexes are observed between 150 and 200 °C in air and are assigned to the presence of (NH4)2C2O4 in the citrato-oxalato-VO(2+) solution. Both precursor solutions are successfully used for the formation of crystalline vanadium oxide nanostructures on SiO2, after thermal annealing at 500 °C in a 0.1% O2 atmosphere. However, the citrato-oxalato-VO(2+) and the oxalate-free citrato-VO(2+) solution result in the formation of monoclinic V6O13 and monoclinic VO2, respectively.

  15. Vanadyl (IV) and vanadate (V) binding to selected endogenous phosphate, carboxyl, and amino ligands; calculations of cellular vanadium species distribution.

    PubMed

    Nechay, B R; Nanninga, L B; Nechay, P S

    1986-11-15

    Vanadium enters cells as vanadate (V) where it is reduced to vanadyl (IV), VO2+. Vanadate species at plasma pH, H2VO4-, and HVO4(2-) are referred to as VO3-. To gain an insight into the subcellular vanadium distribution we measured the binding of VO3- and VO2+ to extra- and intracellular ligands, and calculated free and bound fractions of these ions for expected in vivo conditions. The association constants (K) were determined by the pH shift caused by an addition of VOSO4 or NaVO3 to individual ligand solutions at 20 degrees C and a pH equal to the pK of the reactive groups. The pk's for binding of VO2+ were ATP, 5.9; ADP, 5.5; AMP, 5.1; Pi 4.3; creatine phosphate (CP), 3.6; glutamic acid, 3.4; aspartic acid, 3.1; human serum albumin, 3.1; glutathione, 2.7; ascorbic acid, 3.3; citric acid, 4.0. The pk of VO3- and human serum albumin was 3.3 and of that VO3- and glutathione was 4.2. VO3- did not bind to ATP, even via Mg2+ or Ca2+ bridges. We calculated that in cells approximately 1% of total VO2+ is unbound, which is 10(-10)-10(-9) M since published values for total vanadium (mainly VO2+) concentrations in tissues are on the order of 10(-8)-10(-7) M. Free VO2+ may be even less because of binding to additional ligands not considered and due to spontaneous hydrolysis to VOOH+ and VO(OH)2(2+) at intracellular pH. The binding of VO2+ to each ligand was corrected for presence of multiple ligands and competition by H+, K+, and Mg2+. In cells with no CP, up to 70% of VO2+ is bound to phosphates and up to 29% to proteins; in cells with 30 mM CP (as in muscle), approximately 95% is bound to phosphates (CP binds up to 61% of total VO2+) and approximately 4% to proteins; in cells with 2 mM ascorbic acid (as in brain), the vitamin binds approximately 3% of total VO2+. These binding values apply for the total VO2+ concentration range of 10(-8)-10(-5) M. The intracellular binding and a reducing environment protect the freshly reduced VO2+ from oxidation to VO3- that would otherwise occur at neutral pH. This strong affinity of VO2+ primarily for phosphates also explains the mechanism for the intracellular accumulation of vanadium which is a factor in previously observed transport of VO3- into cells.(ABSTRACT TRUNCATED AT 400 WORDS)

  16. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training.

    PubMed

    Stöggl, Thomas L; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male ( n = 33) and female ( n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO 2peak ): 61.9 ± 8.0 mL·kg -1 ·min -1 ] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001) and peak lactate ( P = 0.001) during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L -1 ) was changed ( P > 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes.

  17. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    PubMed Central

    Stöggl, Thomas L.; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001) and peak lactate (P = 0.001) during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1) was changed (P > 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes. PMID:28824457

  18. Respiratory response of grass carp Ctenopharyngodon idellus to dissolved oxygen changes at three acclimation temperatures.

    PubMed

    Zhao, Zhigang; Dong, Shuanglin; Xu, Qiyou

    2018-02-01

    Respiratory parameters of grass carp were studied during dissolved oxygen (DO) changes from normal DO to hypoxia, then return to normal DO at 15, 25, and 30 °C acclimation, respectively. The results showed that with increases of acclimation temperature at normoxia the respiratory frequency (f R ), oxygen consumption rate (VO 2 ), respiratory stroke volume (V S.R ), gill ventilation (V G ), and V G /VO 2 of grass carp increased significantly, but the oxygen extraction efficiency (EO 2 ) of fish decreased significantly (P < 0.05). With declines of DO levels, the f R , V S.R , V G , and V G /VO 2 of fish increased significantly at different acclimation temperatures (P < 0.05). A slight increase was found in VO 2 , and the EO 2 of fish remained almost constant above DO levels of 3.09, 2.91, and 2.54 mg l -1 at 15, 25, and 30 °C, while the VO 2 and EO 2 began to decrease significantly with further reductions in DO levels (P < 0.05). After 0.5 h of recovery to normoxia from hypoxia at three acclimation, the f R , V S.R , V G , and V G /VO 2 of the fish decreased sharply; meanwhile, the VO 2 and EO 2 increased sharply (P < 0.05). The respiratory parameters of fish gradually approached initial values with prolonged recovery time to normoxia, and reached their initial values in 2.5 h at 25 and 30 °C acclimation. The critical oxygen concentrations (C c ) of fish for VO 2 were 2.42 mg l -1 at 15 °C, 2.02 mg l -1 at 25 °C, and 1.84 mg l -1 at 30 °C, respectively. The results suggest that grass carp are highly adapted to varied DO and short-term hypoxia environments.

  19. High power, diffraction limited picosecond oscillator based on Nd:GdVO4 bulk crystal with σ polarized in-band pumping.

    PubMed

    Lin, Hua; Guo, Jie; Gao, Peng; Yu, Hai; Liang, Xiaoyan

    2016-06-27

    We report on a high power passively mode-locked picosecond oscillator based on Nd:GdVO4 crystal with σ polarized in-band pumping. Thermal gradient and thermal aberration was greatly decreased with proposed configuration. Maximum output power of 37 W at 81 MHz repetition rate with 19.3 ps pulse duration was achieved directly from Nd:GdVO4 oscillator, corresponding to 51% optical efficiency. The oscillator maintained diffraction limited beam quality of M2 < 1.05 at different output coupling with pulse duration between 11.2 ps to 19.3 ps.

  20. Marathon performance, anaerobic threshold, and onset of blood lactate accumulation.

    PubMed

    Tanaka, K; Matsuura, Y

    1984-09-01

    The study tested the hypothesis that running velocity corresponding to the anaerobic threshold (VAT) would more accurately approximate the actually measured marathon race velocity (VM) than would running velocity corresponding to the so-called onset of blood lactate (4 mM) accumulation (VOBLA). The VAT (4.57 m X s-1) well approximated the VM (4.49 m X s-1), whereas the VOBLA (5.30 m X s-1) differed significantly from the VM. In addition, the VAT (r = 0.781) correlated with VM to a greater extent than did the VOBLA (r = 0.682). When the VAT (X1) was combined with delta % maximum O2 consumption (VO2max) (%VO2max at the OBLA minus %VO2max at the AT; X2) and VO2max (ml X min-1 x kg-1; X3), variation in the VM accounted for increased profoundly from 61 to 88%. Thus one of the useful equations formulated with high predictive accuracy was VM (m X s-1) = 1.312X1 + 0.0346X2 - 0.00993X3 - 1.272. Our study demonstrates that the anaerobic threshold (AT) is more closely associated with marathon running performance and that the degree of the association is raised when delta %VO2max and/or VO2max are combined as additional information.

  1. Effects of high-intensity interval versus continuous exercise training on post-exercise heart rate recovery in coronary heart-disease patients.

    PubMed

    Villelabeitia-Jaureguizar, Koldobika; Vicente-Campos, Davinia; Senen, Alejandro Berenguel; Jiménez, Verónica Hernández; Garrido-Lestache, María Elvira Barrios; Chicharro, Jose López

    2017-10-01

    Heart rate recovery (HRR) has been considered a prognostic and mortality indicator in both healthy and coronary patients. Physical exercise prescription has shown improvements in VO 2 peak and HRR, but most of the studies have been carried out applying continuous training at a moderate intensity, being very limited the use of protocols of high intensity interval training in coronary patients. We aimed to compare the effects of a moderate continuous training (MCT) versus a high intensity interval training (HIIT) programme on VO 2 peak and HRR. Seventy three coronary patients were assigned to either HIIT or MCT groups for 8weeks. Incremental exercise tests in a cycloergometer were performed to obtain VO 2 peak data and heart rate was monitored during and after the exercise test to obtain heart rate recovery data. Both exercise programmes significantly increase VO 2 peak with a higher increase in the HIIT group (HIIT: 4.5±4.46ml/kg/min vs MCT: 2.46±3.57ml/kg/min; p=0.039). High intensity interval training resulted in a significantly increase in HRR at the first and second minute of the recovery phase (15,44±7,04 vs 21,22±6,62, p<0,0001 and 23,73±9,64 vs 31,52±8,02, p<0,0001, respectively). The results of our research show that the application of HIIT to patients with chronic ischemic heart disease of low risk resulted in an improvement in VO 2 peak, and also improvements in post-exercise heart-rate recovery, compared with continuous training. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Estimation of maximal oxygen uptake by bioelectrical impedance analysis.

    PubMed

    Stahn, Alexander; Terblanche, Elmarie; Grunert, Sven; Strobel, Günther

    2006-02-01

    Previous non-exercise models for the prediction of maximal oxygen uptake VO(2max) have failed to accurately discriminate cardiorespiratory fitness within large cohorts. The aim of the present study was to evaluate the feasibility of a completely indirect method for predicting VO(2max) that was based on bioelectrical impedance analysis (BIA) in 66 young, healthy fit men and women. Multiple, stepwise regression analysis was used to determine the usefulness of BIA and additional covariates to estimate VO(2max) (ml min(-1)). BIA was highly correlated to VO(2max) (r = 0.914; P < 0.001) and entered the regression equation first. The inclusion of gender and a physical activity rating further improved the model which accounted for 88% of the variance in VO(2max) and resulted in a relative standard error of the estimate (SEE) of 7.2%. Substantial agreement between the methods was confirmed by the fact that nearly all the differences were within +/-2 SD. Furthermore, in contrast to previously published non-exercise models, no trend of a reduction in prediction accuracy with increasing VO(2max) values was apparent. It was concluded that a non-exercise model based on BIA might be a rapid and useful technique to estimate VO(2max), when a direct test does not seem feasible. However, though the present results are useful to determine the viability of the method, further refinement of the BIA approach and its validation in a large, diverse population is needed before it can be applied to the clinical and epidemiological settings.

  3. Video-Only Cardiopulmonary Resuscitation Education for High-Risk Families Before Hospital Discharge: A Multicenter Pragmatic Trial

    PubMed Central

    Blewer, Audrey L.; Putt, Mary E.; Becker, Lance B.; Riegel, Barbara J.; Li, Jiaqi; Leary, Marion; Shea, Judy A.; Kirkpatrick, James N.; Berg, Robert A.; Nadkarni, Vinay M.; Groeneveld, Peter W.; Abella, Benjamin S.

    2016-01-01

    Background CPR training rates in the US are low, highlighting the need to develop CPR educational approaches that are simpler, with broader dissemination potential. The minimum training required to ensure long-term skill retention remains poorly characterized. We compared CPR skill retention among laypersons randomized to training with video-only (VO; no manikin) to those trained with a video self-instruction kit (VSI; with manikin). We hypothesized that VO training would be non-inferior to the VSI approach with respect to chest compression (CC) rate. Methods and Results We performed a prospective cluster randomized trial of CPR education for family members of high-risk cardiac patients on hospital cardiac units, using a multicenter pragmatic design. Eight hospitals were randomized to offer either VO or VSI training before discharge using volunteer trainers. CPR skills were assessed six months post-training. Mean CC rate among those trained with VO compared to VSI was assessed with a non-inferiority margin set at 8 CC per min (cpm); as a secondary outcome, mean differences in CC depth were assessed. From 2/2012 to 5/2015, 1464 subjects were enrolled and 522 subjects completed a skills assessment. The mean CC rates were 87.7(VO) cpm and 89.3 (VSI) cpm; we concluded non-inferiority for VO based on a mean difference of −1.6 (90% CI: −5.2, 2.1). The mean CC depth was 40.2 mm (VO) and 45.8 mm (VSI) with a mean difference of −5.6 (95% CI: −7.6, −3.7). Results were similar after multivariate regression adjustment. Conclusions In this large prospective trial of CPR skill retention, VO training yielded a non-inferior difference in CC rate compared to VSI training. CC depth was greater in the VSI group. These findings suggest a potential trade-off in efforts for broad dissemination of basic CPR skills; VO training might allow for greater scalability and dissemination, but with a potential reduction in CC depth. Clinical Trial Registration URL: ClinicalTrials.gov, Identifier: NCT01514656. PMID:27703033

  4. Photo-driven nanoactuators based on carbon nanocoils and vanadium dioxide bimorphs.

    PubMed

    Ma, He; Zhang, Xinping; Cui, Ruixue; Liu, Feifei; Wang, Meng; Huang, Cuiying; Hou, Jiwei; Wang, Guang; Wei, Yang; Jiang, Kaili; Pan, Lujun; Liu, Kai

    2018-06-06

    Photo-driven actuators are highly desirable in various smart systems owing to the advantages of wireless control and possible actuation by solar energy. Miniaturization of photo-driven actuators is particularly essential in micro-robotics and micro-/nano-electro-mechanical systems. However, it remains a great challenge to build up nano-scale photo-driven actuators with competitive performance in amplitude, response speed, and lifetime. In this work, we developed photo-driven nanoactuators based on bimorph structures of vanadium dioxides (VO2) and carbon nanocoils (CNCs). Activated by the huge structural phase transition of VO2, the photo-driven VO2/CNC nanoactuators deliver a giant amplitude, a fast response up to 9400 Hz, and a long lifetime more than 10 000 000 actuation cycles. Both experimental and simulation results show that the helical structure of CNCs enables a low photo-driven threshold of VO2/CNC nanoactuators, which provides an effective method to construct photo-driven nanoactuators with low power consumption. Our photo-driven VO2/CNC nanoactuators would find potential applications in nano-scale electrical/optical switches and other smart devices.

  5. Effect of limb cooling on peripheral and global oxygen consumption in neonates

    PubMed Central

    Hassan, I; Wickramasinghe, Y; Spencer, S

    2003-01-01

    Aim: To evaluate peripheral oxygen consumption (VO2) measurements using near infrared spectroscopy (NIRS) with arterial occlusion in healthy term neonates by studying the effect of limb cooling on peripheral and global VO2. Subjects and methods: Twenty two healthy term neonates were studied. Peripheral VO2 was measured by NIRS using arterial occlusion and measurement of the oxyhaemoglobin (HbO2) decrement slope. Global VO2 was measured by open circuit calorimetry. Global and peripheral VO2 was measured in each neonate before and after limb cooling. Results: In 10 neonates, a fall in forearm temperature of 2.2°C (mild cooling) decreased forearm VO2 by 19.6% (p < 0.01). Global VO2 did not change. In 12 neonates, a fall in forearm temperature of 4°C (moderate cooling) decreased forearm VO2 by 34.7% (p < 0.01). Global VO2 increased by 17.6% (p < 0.05). Conclusions: The NIRS arterial occlusion method is able to measure changes in peripheral VO2 induced by limb cooling. The changes are more pronounced with moderate limb cooling when a concomitant rise in global VO2 is observed. Change in peripheral temperature must be taken into consideration in the interpretation of peripheral VO2 measurements in neonates. PMID:12598504

  6. Effect of limb cooling on peripheral and global oxygen consumption in neonates.

    PubMed

    Hassan, I A-A; Wickramasinghe, Y A; Spencer, S A

    2003-03-01

    To evaluate peripheral oxygen consumption (VO(2)) measurements using near infrared spectroscopy (NIRS) with arterial occlusion in healthy term neonates by studying the effect of limb cooling on peripheral and global VO(2). Twenty two healthy term neonates were studied. Peripheral VO(2) was measured by NIRS using arterial occlusion and measurement of the oxyhaemoglobin (HbO(2)) decrement slope. Global VO(2) was measured by open circuit calorimetry. Global and peripheral VO(2) was measured in each neonate before and after limb cooling. In 10 neonates, a fall in forearm temperature of 2.2 degrees C (mild cooling) decreased forearm VO(2) by 19.6% (p < 0.01). Global VO(2) did not change. In 12 neonates, a fall in forearm temperature of 4 degrees C (moderate cooling) decreased forearm VO(2) by 34.7% (p < 0.01). Global VO(2) increased by 17.6% (p < 0.05). The NIRS arterial occlusion method is able to measure changes in peripheral VO(2) induced by limb cooling. The changes are more pronounced with moderate limb cooling when a concomitant rise in global VO(2) is observed. Change in peripheral temperature must be taken into consideration in the interpretation of peripheral VO(2) measurements in neonates.

  7. Endurance Performance during Severe-Intensity Intermittent Cycling: Effect of Exercise Duration and Recovery Type.

    PubMed

    Barbosa, Luis F; Denadai, Benedito S; Greco, Camila C

    2016-01-01

    Slow component of oxygen uptake (VO 2 SC) kinetics and maximal oxygen uptake (VO 2 max) attainment seem to influence endurance performance during constant-work rate exercise (CWR) performed within the severe intensity domain. In this study, it was hypothesized that delaying the attainment of VO 2 max by reducing the rates at which VO 2 increases with time (VO 2 SC kinetics) would improve the endurance performance during severe-intensity intermittent exercise performed with different work:recovery duration and recovery type in active individuals. After the estimation of the parameters of the VO 2 SC kinetics during CWR exercise, 18 males were divided into two groups (Passive and Active recovery) and performed at different days, two intermittent exercises to exhaustion (at 95% IVO 2 max, with work: recovery ratio of 2:1) with the duration of the repetitions calculated from the onset of the exercise to the beginning of the VO 2 SC (Short) or to the half duration of the VO 2 SC (Long). The active recovery was performed at 50% IVO 2 max. The endurance performance during intermittent exercises for the Passive (Short = 1523 ± 411; Long = 984 ± 260 s) and Active (Short = 902 ± 239; Long = 886 ± 254 s) groups was improved compared with CWR condition (Passive = 540 ± 116; Active = 489 ± 84 s). For Passive group, the endurance performance was significantly higher for Short than Long condition. However, no significant difference between Short and Long conditions was found for Active group. Additionally, the endurance performance during Short condition was higher for Passive than Active group. The VO 2 SC kinetics was significantly increased for CWR (Passive = 0.16 ± 0.04; Active = 0.16 ± 0.04 L.min -2 ) compared with Short (Passive = 0.01 ± 0.01; Active = 0.03 ± 0.04 L.min -2 ) and Long (Passive = 0.02 ± 0.01; Active = 0.01 ± 0.01 L.min -2 ) intermittent exercise conditions. No significant difference was found among the intermittent exercises. It can be concluded that the endurance performance is negatively influenced by active recovery only during shorter high-intensity intermittent exercise. Moreover, the improvement in endurance performance seems not be explained by differences in the VO 2 SC kinetics, since its values were similar among all intermittent exercise conditions.

  8. Maximal metabolic rates during voluntary exercise, forced exercise, and cold exposure in house mice selectively bred for high wheel-running.

    PubMed

    Rezende, Enrico L; Chappell, Mark A; Gomes, Fernando R; Malisch, Jessica L; Garland, Theodore

    2005-06-01

    Selective breeding for high wheel-running activity has generated four lines of laboratory house mice (S lines) that run about 170% more than their control counterparts (C lines) on a daily basis, mostly because they run faster. We tested whether maximum aerobic metabolic rates (V(O2max)) have evolved in concert with wheel-running, using 48 females from generation 35. Voluntary activity and metabolic rates were measured on days 5+6 of wheel access (mimicking conditions during selection), using wheels enclosed in metabolic chambers. Following this, V(O2max) was measured twice on a motorized treadmill and twice during cold-exposure in a heliox atmosphere (HeO2). Almost all measurements, except heliox V(O2max), were significantly repeatable. After accounting for differences in body mass (S < C) and variation in age at testing, S and C did not differ in V(O2max) during forced exercise or in heliox, nor in maximal running speeds on the treadmill. However, running speeds and V(O2max) during voluntary exercise were significantly higher in S lines. Nevertheless, S mice never voluntarily achieved the V(O2max) elicited during their forced treadmill trials, suggesting that aerobic capacity per se is not limiting the evolution of even higher wheel-running speeds in these lines. Our results support the hypothesis that S mice have genetically higher motivation for wheel-running and they demonstrate that behavior can sometimes evolve independently of performance capacities. We also discuss the possible importance of domestication as a confounding factor to extrapolate results from this animal model to natural populations.

  9. VO2 and VCO2 variabilities through indirect calorimetry instrumentation.

    PubMed

    Cadena-Méndez, Miguel; Escalante-Ramírez, Boris; Azpiroz-Leehan, Joaquín; Infante-Vázquez, Oscar

    2013-01-01

    The aim of this paper is to understand how to measure the VO2 and VCO2 variabilities in indirect calorimetry (IC) since we believe they can explain the high variation in the resting energy expenditure (REE) estimation. We propose that variabilities should be separately measured from the VO2 and VCO2 averages to understand technological differences among metabolic monitors when they estimate the REE. To prove this hypothesis the mixing chamber (MC) and the breath-by-breath (BbB) techniques measured the VO2 and VCO2 averages and their variabilities. Variances and power spectrum energies in the 0-0.5 Hertz band were measured to establish technique differences in steady and non-steady state. A hybrid calorimeter with both IC techniques studied a population of 15 volunteers that underwent the clino-orthostatic maneuver in order to produce the two physiological stages. The results showed that inter-individual VO2 and VCO2 variabilities measured as variances were negligible using the MC while variabilities measured as spectral energies using the BbB underwent 71 and 56% (p < 0.05), increase respectively. Additionally, the energy analysis showed an unexpected cyclic rhythm at 0.025 Hertz only during the orthostatic stage, which is new physiological information, not reported previusly. The VO2 and VCO2 inter-individual averages increased to 63 and 39% by the MC (p < 0.05) and 32 and 40% using the BbB (p < 0.1), respectively, without noticeable statistical differences among techniques. The conclusions are: (a) metabolic monitors should simultaneously include the MC and the BbB techniques to correctly interpret the steady or non-steady state variabilities effect in the REE estimation, (b) the MC is the appropriate technique to compute averages since it behaves as a low-pass filter that minimizes variances, (c) the BbB is the ideal technique to measure the variabilities since it can work as a high-pass filter to generate discrete time series able to accomplish spectral analysis, and (d) the new physiological information in the VO2 and VCO2 variabilities can help to understand why metabolic monitors with dissimilar IC techniques give different results in the REE estimation.

  10. V02 'overshoot' during moderate-intensity exercise in endurance-trained athletes: the influence of exercise modality.

    PubMed

    Kilding, Andrew E; Jones, Andrew M

    2008-02-01

    The purpose of this study was to investigate the influence of exercise modality on the 'overshoot' in V(O2) that has been reported following the onset of moderate-intensity (below the gas exchange threshold, GET) exercise in endurance athletes. Seven trained endurance cyclists and seven trained endurance runners completed six square-wave transitions to a work-rate or running speed requiring 80% of mode-specific GET during both cycle and treadmill running exercise. The kinetics of V(O2) was assessed using non-linear regression and any overshoot in V(O2) was quantified as the integrated volume (IV) of O(2) consumed above the steady-state requirement. During cycling, an overshoot in V(O2) was evident in all seven cyclists (IV = 136 +/- 41 ml) and in four runners (IV = 81 +/- 94 ml). During running, an overshoot in V(O2) was evident in four runners (IV = 72 +/- 61 ml) but no cyclists. These data challenge the notion that V(O2) always rises towards a steady-state with near-exponential kinetics in this exercise intensity domain. The greater incidence of the V(O2) overshoot during cycling (11/14 subjects) compared to running (4/14 subjects) indicates that the overshoot phenomenon is related to an interaction between high levels of aerobic fitness and exercise modality. We speculate that a transient loss in muscle efficiency as a consequence of a non-constant ATP requirement following the onset of constant-work-rate exercise or an initially excessive recruitment of motor units (relative to the work-rate) might contribute to the overshoot phenomenon.

  11. Association of Lower Limb Compression Garments During High-Intensity Exercise with Performance and Physiological Responses: A Systematic Review and Meta-analysis.

    PubMed

    da Silva, César Augusto; Helal, Lucas; da Silva, Roberto Pacheco; Belli, Karlyse Claudino; Umpierre, Daniel; Stein, Ricardo

    2018-05-02

    Although compression garments are used to improve sports performance, methodological approaches and the direction of evidence regarding garments for use in high-intensity exercise settings are diverse. Our primary aim was to summarize the association between lower-limb compression garments (LLCGs) and changes in sports performance during high-intensity exercise. We also aimed to summarize evidence about the following physiological parameters related to sports performance: vertical jump height (VJ), maximal oxygen uptake (VO 2 max), submaximal oxygen uptake (VO 2 submax), blood lactate concentrations ([La]), and ratings of perceived exertion (RPE, 6-20 Borg scale). We searched electronic databases (PubMed, EMBASE, Cochrane Library, and ClinicalTrials.gov) and reference lists for previous reviews. Eligible studies included randomized controlled trials with athletes or physically active subjects (≥ 18 years) using any type of LLCG during high-intensity exercise. The results were described as weighted mean difference (WMD) with a 95% confidence interval (95% CI). The 23 included studies showed low statistical heterogeneity for the pooled outcomes. We found that LLCGs yielded similar running performance to controls (50-400 m: WMD 0.06 s [95% CI - 1.99 to 2.11]; 800-3000 m: WMD 6.10 s [95% CI - 7.23 to 19.43]; > 5000 m: WMD 1.01 s [95% CI - 84.80 to 86.82]). Likewise, we found no evidence that LLCGs were superior in secondary outcomes (VJ: WMD 2.25 cm [95% CI - 2.51 to 7.02]; VO 2 max: WMD 0.24 mL.kg -1 .min -1 [95% CI - 1.48 to 1.95]; VO 2 submax: WMD - 0.26 mL.kg -1 .min -1 [95% CI - 2.66 to 2.14]; [La]: WMD 0.19 mmol/L [95% CI - 0.22 to 0.60]; RPE: WMD - 0.20 points [95% CI - 0.48 to 0.08]). LLCGs were not associated with improved performance in VJ, VO 2 max, VO 2 submax, [La], or RPE during high-intensity exercise. Such evidence should be taken into account when considering using LLCGs to enhance running performance.

  12. Computational Approach for Epitaxial Polymorph Stabilization through Substrate Selection.

    PubMed

    Ding, Hong; Dwaraknath, Shyam S; Garten, Lauren; Ndione, Paul; Ginley, David; Persson, Kristin A

    2016-05-25

    With the ultimate goal of finding new polymorphs through targeted synthesis conditions and techniques, we outline a computational framework to select optimal substrates for epitaxial growth using first principle calculations of formation energies, elastic strain energy, and topological information. To demonstrate the approach, we study the stabilization of metastable VO2 compounds which provides a rich chemical and structural polymorph space. We find that common polymorph statistics, lattice matching, and energy above hull considerations recommends homostructural growth on TiO2 substrates, where the VO2 brookite phase would be preferentially grown on the a-c TiO2 brookite plane while the columbite and anatase structures favor the a-b plane on the respective TiO2 phases. Overall, we find that a model which incorporates a geometric unit cell area matching between the substrate and the target film as well as the resulting strain energy density of the film provide qualitative agreement with experimental observations for the heterostructural growth of known VO2 polymorphs: rutile, A and B phases. The minimal interfacial geometry matching and estimated strain energy criteria provide several suggestions for substrates and substrate-film orientations for the heterostructural growth of the hitherto hypothetical anatase, brookite, and columbite polymorphs. These criteria serve as a preliminary guidance for the experimental efforts stabilizing new materials and/or polymorphs through epitaxy. The current screening algorithm is being integrated within the Materials Project online framework and data and hence publicly available.

  13. Computational Approach for Epitaxial Polymorph Stabilization through Substrate Selection

    DOE PAGES

    Ding, Hong; Dwaraknath, Shyam S.; Garten, Lauren; ...

    2016-05-04

    With the ultimate goal of finding new polymorphs through targeted synthesis conditions and techniques, we outline a computational framework to select optimal substrates for epitaxial growth using first principle calculations of formation energies, elastic strain energy, and topological information. To demonstrate the approach, we study the stabilization of metastable VO 2 compounds which provides a rich chemical and structural polymorph space. Here, we find that common polymorph statistics, lattice matching, and energy above hull considerations recommends homostructural growth on TiO 2 substrates, where the VO 2 brookite phase would be preferentially grown on the a-c TiO 2 brookite plane whilemore » the columbite and anatase structures favor the a-b plane on the respective TiO 2 phases. Overall, we find that a model which incorporates a geometric unit cell area matching between the substrate and the target film as well as the resulting strain energy density of the film provide qualitative agreement with experimental observations for the heterostructural growth of known VO 2 polymorphs: rutile, A and B phases. The minimal interfacial geometry matching and estimated strain energy criteria provide several suggestions for substrates and substrate-film orientations for the heterostructural growth of the hitherto hypothetical anatase, brookite, and columbite polymorphs. Our criteria serve as a preliminary guidance for the experimental efforts stabilizing new materials and/or polymorphs through epitaxy. The current screening algorithm is being integrated within the Materials Project online framework and data and hence publicly available.« less

  14. Computational Approach for Epitaxial Polymorph Stabilization through Substrate Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Hong; Dwaraknath, Shyam S.; Garten, Lauren

    With the ultimate goal of finding new polymorphs through targeted synthesis conditions and techniques, we outline a computational framework to select optimal substrates for epitaxial growth using first principle calculations of formation energies, elastic strain energy, and topological information. To demonstrate the approach, we study the stabilization of metastable VO2 compounds which provides a rich chemical and structural polymorph space. We find that common polymorph statistics, lattice matching, and energy above hull considerations recommends homostructural growth on TiO2 substrates, where the VO2 brookite phase would be preferentially grown on the a-c TiO2 brookite plane while the columbite and anatase structuresmore » favor the a-b plane on the respective TiO2 phases. Overall, we find that a model which incorporates a geometric unit cell area matching between the substrate and the target film as well as the resulting strain energy density of the film provide qualitative agreement with experimental observations for the heterostructural growth of known VO2 polymorphs: rutile, A and B phases. The minimal interfacial geometry matching and estimated strain energy criteria provide several suggestions for substrates and substrate-film orientations for the heterostructural growth of the hitherto hypothetical anatase, brookite, and columbite polymorphs. These criteria serve as a preliminary guidance for the experimental efforts stabilizing new materials and/or polymorphs through epitaxy. The current screening algorithm is being integrated within the Materials Project online framework and data and hence publicly available.« less

  15. Computational Approach for Epitaxial Polymorph Stabilization through Substrate Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Hong; Dwaraknath, Shyam S.; Garten, Lauren

    With the ultimate goal of finding new polymorphs through targeted synthesis conditions and techniques, we outline a computational framework to select optimal substrates for epitaxial growth using first principle calculations of formation energies, elastic strain energy, and topological information. To demonstrate the approach, we study the stabilization of metastable VO 2 compounds which provides a rich chemical and structural polymorph space. Here, we find that common polymorph statistics, lattice matching, and energy above hull considerations recommends homostructural growth on TiO 2 substrates, where the VO 2 brookite phase would be preferentially grown on the a-c TiO 2 brookite plane whilemore » the columbite and anatase structures favor the a-b plane on the respective TiO 2 phases. Overall, we find that a model which incorporates a geometric unit cell area matching between the substrate and the target film as well as the resulting strain energy density of the film provide qualitative agreement with experimental observations for the heterostructural growth of known VO 2 polymorphs: rutile, A and B phases. The minimal interfacial geometry matching and estimated strain energy criteria provide several suggestions for substrates and substrate-film orientations for the heterostructural growth of the hitherto hypothetical anatase, brookite, and columbite polymorphs. Our criteria serve as a preliminary guidance for the experimental efforts stabilizing new materials and/or polymorphs through epitaxy. The current screening algorithm is being integrated within the Materials Project online framework and data and hence publicly available.« less

  16. A novel inorganic precipitation-peptization method for VO2 sol and VO2 nanoparticles preparation: Synthesis, characterization and mechanism.

    PubMed

    Li, Yao; Jiang, Peng; Xiang, Wei; Ran, Fanyong; Cao, Wenbin

    2016-01-15

    In this paper, a simple, safe and cost-saving precipitation-peptization method was proposed to prepare VO2 sol by using inorganic VOSO4-NH3⋅H2O-H2O2 reactants system in air under room temperature. In this process, VOSO4 was firstly precipitated to form VO(OH)2, then monometallic species of VO(O2)(OH)(-) were formed through the coordination between VO(OH)2 and H2O2. The rearrangement of VO(O2)(OH)(-) in a nonplanar pattern and intermolecular condensation reactions result in multinuclear species. Finally, VO2 sol is prepared through the condensation reactions between the multinuclear species. After drying the obtained sol at 40°C, VO2 xerogel exhibiting monoclinic crystal structure with the space group of C2/m was prepared. The crystal structure of VO2 nanoparticles was transferred to monoclinic crystal structure with the space group of P21/c (VO2(M)) by annealing the xerogel at 550°C. Both XRD and TEM analysis indicated that the nanoparticles possess good crystallinity with crystallite size of 34.5nm as estimated by Scherrer's method. These results suggest that the VO2 sol has been prepared successfully through the proposed simple method. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Genetic polymorphisms to predict gains in maximal O2 uptake and knee peak torque after a high intensity training program in humans.

    PubMed

    Yoo, Jinho; Kim, Bo-Hyung; Kim, Soo-Hwan; Kim, Yangseok; Yim, Sung-Vin

    2016-05-01

    The study aimed to identify single nucleotide polymorphisms (SNPs) that significantly influenced the level of improvement of two kinds of training responses, including maximal O2 uptake (V'O2max) and knee peak torque of healthy adults participating in the high intensity training (HIT) program. The study also aimed to use these SNPs to develop prediction models for individual training responses. 79 Healthy volunteers participated in the HIT program. A genome-wide association study, based on 2,391,739 SNPs, was performed to identify SNPs that were significantly associated with gains in V'O2max and knee peak torque, following 9 weeks of the HIT program. To predict two training responses, two independent SNPs sets were determined using linear regression and iterative binary logistic regression analysis. False discovery rate analysis and permutation tests were performed to avoid false-positive findings. To predict gains in V'O2max, 7 SNPs were identified. These SNPs accounted for 26.0 % of the variance in the increment of V'O2max, and discriminated the subjects into three subgroups, non-responders, medium responders, and high responders, with prediction accuracy of 86.1 %. For the knee peak torque, 6 SNPs were identified, and accounted for 27.5 % of the variance in the increment of knee peak torque. The prediction accuracy discriminating the subjects into the three subgroups was estimated as 77.2 %. Novel SNPs found in this study could explain, and predict inter-individual variability in gains of V'O2max, and knee peak torque. Furthermore, with these genetic markers, a methodology suggested in this study provides a sound approach for the personalized training program.

  18. Comparison of normalized maximum aerobic capacity and body composition of sumo wrestlers to athletes in combat and other sports.

    PubMed

    Beekley, Matthew D; Abe, Takashi; Kondo, Masakatsu; Midorikawa, Taishi; Yamauchi, Taro

    2006-01-01

    Sumo wrestling is unique in combat sport, and in all of sport. We examined the maximum aerobic capacity and body composition of sumo wrestlers and compared them to untrained controls. We also compared "aerobic muscle quality", meaning VO2max normalized to predicted skeletal muscle mass (SMM) (VO2max /SMM), between sumo wrestlers and controls and among previously published data for male athletes from combat, aerobic, and power sports. Sumo wrestlers, compared to untrained controls, had greater (p < 0.05) body mass (mean ± SD; 117.0 ± 4.9 vs. 56.1 ± 9.8 kg), percent fat (24.0 ± 1.4 vs. 13.3 ± 4.5), fat-free mass (88.9 ± 4.2 vs. 48.4 ± 6.8 kg), predicted SMM (48.2 ± 2.9 vs. 20.6 ± 4.7 kg) and absolute VO2max (3.6 ± 1.3 vs. 2.5 ± 0.7 L·min(-1)). Mean VO2max /SMM (ml·kg SMM(-1)·min(-1)) was significantly different (p < 0.05) among aerobic athletes (164.8 ± 18.3), combat athletes (which was not different from untrained controls; 131.4 ± 9.3 and 128.6 ± 13.6, respectively), power athletes (96.5 ± 5.3), and sumo wrestlers (71.4 ± 5.3). There was a strong negative correlation (r = - 0.75) between percent body fat and VO2max /SMM (p < 0.05). We conclude that sumo wrestlers have some of the largest percent body fat and fat-free mass and the lowest "aerobic muscle quality "(VO2max /SMM), both in combat sport and compared to aerobic and power sport athletes. Additionally, it appears from analysis of the relationship between SMM and absolute VO2max for all sports that there is a "ceiling "at which increases in SMM do not result in additional increases in absolute VO2max. Key PointsSumo wrestlers have a high absolute VO2max compared to untrained controls.However, sumo wrestlers have a low VO2max /kg of skeletal muscle mass compared to other combat sports, other strength/power sports, and untrained controls.The reason for this is unknown, but is probably related to alterations in sumo skeletal muscle compared to other sports.Based on the present and previous data, there appears to be a "ceiling "at which increases in skeletal muscle mass do not result in additional increases in absolute VO2max.

  19. Peapod-like Li3 VO4 /N-Doped Carbon Nanowires with Pseudocapacitive Properties as Advanced Materials for High-Energy Lithium-Ion Capacitors.

    PubMed

    Shen, Laifa; Lv, Haifeng; Chen, Shuangqiang; Kopold, Peter; van Aken, Peter A; Wu, Xiaojun; Maier, Joachim; Yu, Yan

    2017-07-01

    Lithium ion capacitors are new energy storage devices combining the complementary features of both electric double-layer capacitors and lithium ion batteries. A key limitation to this technology is the kinetic imbalance between the Faradaic insertion electrode and capacitive electrode. Here, we demonstrate that the Li 3 VO 4 with low Li-ion insertion voltage and fast kinetics can be favorably used for lithium ion capacitors. N-doped carbon-encapsulated Li 3 VO 4 nanowires are synthesized through a morphology-inheritance route, displaying a low insertion voltage between 0.2 and 1.0 V, a high reversible capacity of ≈400 mAh g -1 at 0.1 A g -1 , excellent rate capability, and long-term cycling stability. Benefiting from the small nanoparticles, low energy diffusion barrier and highly localized charge-transfer, the Li 3 VO 4 /N-doped carbon nanowires exhibit a high-rate pseudocapacitive behavior. A lithium ion capacitor device based on these Li 3 VO 4 /N-doped carbon nanowires delivers a high energy density of 136.4 Wh kg -1 at a power density of 532 W kg -1 , revealing the potential for application in high-performance and long life energy storage devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Effect of a prior intermittent run at vVO2max on oxygen kinetics during an all-out severe run in humans.

    PubMed

    Billat, V L; Bocquet, V; Slawinski, J; Laffite, L; Demarle, A; Chassaing, P; Koralsztein, J P

    2000-09-01

    The purpose of this study was to examine the influence of prior intermittent running at VO2max on oxygen kinetics during a continuous severe intensity run and the time spent at VO2max. Eight long-distance runners performed three maximal tests on a synthetic track (400 m) whilst breathing through the COSMED K4 portable telemetric metabolic analyser: i) an incremental test which determined velocity at the lactate threshold (vLT), VO2max and velocity associated with VO2max (vVO2max), ii) a continuous severe intensity run at vLT+50% (vdelta50) of the difference between vLT and vVO2max (91.3+/-1.6% VO2max)preceded by a light continuous 20 minute run at 50% of vVO2max (light warm-up), iii) the same continuous severe intensity run at vdelta50 with a prior interval training exercise (hard warm-up) of repeated hard running bouts performed at 100% of vVO2max and light running at 50% of vVO2max (of 30 seconds each) performed until exhaustion (on average 19+/-5 min with 19+/-5 interval repetitions). This hard warm-up speeded the VO2 kinetics: the time constant was reduced by 45% (28+/-7 sec vs 51+/-37 sec) and the slow component of VO2 (deltaVO2 6-3 min) was deleted (-143+/-271 ml x min(-1) vs 291+/-153 ml x min(-1)). In conclusion, despite a significantly lower total run time at vdelta50 (6 min 19+/-0) min 17 vs 8 min 20+/-1 min 45, p=0.02) after the intermittent warm-up at VO2max, the time spent specifically at VO2max in the severe continuous run at vdelta50 was not significantly different.

  1. Integrating a Semitransparent, Fullerene-Free Organic Solar Cell in Tandem with a BiVO4 Photoanode for Unassisted Solar Water Splitting.

    PubMed

    Peng, Yuelin; Govindaraju, Gokul V; Lee, Dong Ki; Choi, Kyoung-Shin; Andrew, Trisha L

    2017-07-12

    We report an unassisted solar water splitting system powered by a diketopyrrolopyrrole (DPP)-containing semitransparent organic solar cell. Two major merits of this fullerene-free solar cell enable its integration with a BiVO 4 photoanode. First is the high open circuit voltage and high fill factor displayed by this single junction solar cell, which yields sufficient power to effect water splitting when serially connected to an appropriate electrode/catalyst. Second, the wavelength-resolved photoaction spectrum of the DPP-based solar cell has minimal overlap with that of the BiVO 4 photoanode, thus ensuring that light collection across these two components can be optimized. The latter feature enables a new water splitting device configuration wherein the solar cell is placed first in the path of incident light, before the BiVO 4 photoanode, although BiVO 4 has a wider bandgap. This configuration is accessed by replacing the reflective top electrode of the standard DPP-based solar cell with a thin metal film and an antireflection layer, thus rendering the solar cell semitransparent. In this configuration, incident light does not travel through the aqueous electrolyte to reach the solar cell or photoanode, and therefore, photon losses due to the scattering of water are reduced. Moreover, this new configuration allows the BiVO 4 photoanode to be back-illuminated, i.e., through the BiVO 4 /back contact interface, which leads to higher photocurrents compared to front illumination. The combination of a semitransparent single-junction solar cell and a BiVO 4 photoanode coated with oxygen evolution catalysts in a new device configuration yielded an unassisted solar water splitting system with a solar-to-hydrogen conversion efficiency of 2.2% in water.

  2. Electronic structure of strongly reduced (1 ‾ 1 1) surface of monoclinic HfO2

    NASA Astrophysics Data System (ADS)

    Cheng, YingXing; Zhu, Linggang; Ying, Yile; Zhou, Jian; Sun, Zhimei

    2018-07-01

    Material surface is playing an increasingly important role in electronic devices as their size down to nanoscale. Here, by first-principles calculations we studied the surface oxygen-vacancies (Vos) induced electronic-structure variation of HfO2 , in order to explore its potential applications in surface-controlled electronic devices. Firstly, it is found that single Vo tends to segregate onto the surface and attracts each other as they form pairs, making the formation of vacancies-contained functional surface possible. Then extensive Vo-chains whose formation/rupture can represent the high/low conductivity state are constructed. The electronic states induced by the Vos remain localized in the band-gap region for most of the Vo-chains studied here. A transition to a metallic conductance is found in metastable Vo-chain with formation energy increased by 0.25 eV per Vo. Moreover, we highlight the significance of the Hubbard U correction for density functional theory when studying the electronic-structure based conductance in the oxides. By comprehensive calculations, we find a conductivity-stability dilemma of the Vo-chains, providing guideline for understanding and designing the electronic devices based on HfO2 surface.

  3. Suppression of Structural Phase Transition in VO2 by Epitaxial Strain in Vicinity of Metal-insulator Transition

    PubMed Central

    Yang, Mengmeng; Yang, Yuanjun; Bin Hong; Wang, Liangxin; Hu, Kai; Dong, Yongqi; Xu, Han; Huang, Haoliang; Zhao, Jiangtao; Chen, Haiping; Song, Li; Ju, Huanxin; Zhu, Junfa; Bao, Jun; Li, Xiaoguang; Gu, Yueliang; Yang, Tieying; Gao, Xingyu; Luo, Zhenlin; Gao, Chen

    2016-01-01

    Mechanism of metal-insulator transition (MIT) in strained VO2 thin films is very complicated and incompletely understood despite three scenarios with potential explanations including electronic correlation (Mott mechanism), structural transformation (Peierls theory) and collaborative Mott-Peierls transition. Herein, we have decoupled coactions of structural and electronic phase transitions across the MIT by implementing epitaxial strain on 13-nm-thick (001)-VO2 films in comparison to thicker films. The structural evolution during MIT characterized by temperature-dependent synchrotron radiation high-resolution X-ray diffraction reciprocal space mapping and Raman spectroscopy suggested that the structural phase transition in the temperature range of vicinity of the MIT is suppressed by epitaxial strain. Furthermore, temperature-dependent Ultraviolet Photoelectron Spectroscopy (UPS) revealed the changes in electron occupancy near the Fermi energy EF of V 3d orbital, implying that the electronic transition triggers the MIT in the strained films. Thus the MIT in the bi-axially strained VO2 thin films should be only driven by electronic transition without assistance of structural phase transition. Density functional theoretical calculations further confirmed that the tetragonal phase across the MIT can be both in insulating and metallic states in the strained (001)-VO2/TiO2 thin films. This work offers a better understanding of the mechanism of MIT in the strained VO2 films. PMID:26975328

  4. Tennis Play Intensity Distribution and Relation with Aerobic Fitness in Competitive Players

    PubMed Central

    Baiget, Ernest; Fernández-Fernández, Jaime; Iglesias, Xavier; Rodríguez, Ferran A.

    2015-01-01

    The aims of this study were (i) to describe the relative intensity of simulated tennis play based on the cumulative time spent in three metabolic intensity zones, and (ii) to determine the relationships between this play intensity distribution and the aerobic fitness of a group of competitive players. 20 male players of advanced to elite level (ITN) performed an incremental on-court specific endurance tennis test to exhaustion to determine maximal oxygen uptake (VO2max) and the first and second ventilatory thresholds (VT1, VT2). Ventilatory and gas exchange parameters were monitored using a telemetric portable gas analyser (K4 b2, Cosmed, Rome, Italy). Two weeks later the participants played a simulated tennis set against an opponent of similar level. Intensity zones (1: low, 2: moderate, and 3: high) were delimited by the individual VO2 values corresponding to VT1 and VT2, and expressed as percentage of maximum VO2 and heart rate. When expressed relative to VO2max, percentage of playing time in zone 1 (77 ± 25%) was significantly higher (p < 0.001) than in zone 2 (20 ± 21%) and zone 3 (3 ± 5%). Moderate to high positive correlations were found between VT1, VT2 and VO2max, and the percentage of playing time spent in zone 1 (r = 0.68–0.75), as well as low to high inverse correlations between the metabolic variables and the percentage of time spent in zone 2 and 3 (r = -0.49–0.75). Players with better aerobic fitness play at relatively lower intensities. We conclude that players spent more than 75% of the time in their low-intensity zone, with less than 25% of the time spent at moderate to high intensities. Aerobic fitness appears to determine the metabolic intensity that players can sustain throughout the game. PMID:26098638

  5. A Comparison between Alpine Skiing, Cross-Country Skiing and Indoor Cycling on Cardiorespiratory and Metabolic Response

    PubMed Central

    Stöggl, Thomas; Schwarzl, Christoph; Müller, Edith E.; Nagasaki, Masaru; Stöggl, Julia; Scheiber, Peter; Schönfelder, Martin; Niebauer, Josef

    2016-01-01

    Since physical inactivity especially prevails during winter months, we set out to identify outdoor alternatives to indoor cycling (IC) by comparing the metabolic and cardiorespiratory responses during alpine skiing (AS), cross-country skiing (XCS) and IC and analyse the effects of sex, age and fitness level in this comparison. Twenty one healthy subjects performed alpine skiing (AS), cross-country skiing (XCS), and IC. Oxygen uptake (VO2), total energy expenditure (EE), heart rate (HR), lactate, blood glucose and rate of perceived exertion (RPE) were determined during three 4-min stages of low, moderate and high intensity. During XCS and IC VO2max and EE were higher than during AS. At least 2½ hours of AS are necessary to reach the same EE as during one hour of XCS or IC. HR, VO2, lactate, and RPEarms were highest during XCS, whereas RPEwhole-body was similar and RPElegs lower than during AS and IC, respectively. Weight adjusted VO2 and EE were higher in men than in women while fitness level had no effect. Male, fit and young participants were able to increase their EE and VO2 values more pronounced. Both AS and XCS can be individually tailored to serve as alternatives to IC and may thus help to overcome the winter activity deficit. XCS was found to be the most effective activity for generating a high EE and VO2 while AS was the most demanding activity for the legs. Key points During cross-country skiing and indoor cycling VO2max and energy expenditure were higher than during alpine skiing Approximately 2½ hours of alpine skiing are necessary to reach the same energy expenditure of one hour of cross-country skiing or indoor cycling. Alpine skiing and cross-country skiing can be individually tailored to serve as sports alternatives in winter to activity deficit. By applying different skiing modes as parallel ski steering, carving long radii and short turn skiing, metabolic and cardiorespiratory response can be increased during alpine skiing. Male, fit and young participants were able to increase their energy expenditure and VO2 more pronounced with an increase in intensity compared with their counterparts PMID:26957942

  6. Methods for measurement of energy expenditure and substrate concentrations in swimming rats.

    PubMed

    Benthem, L; Bolhuis, J W; van der Leest, J; Steffens, A B; Zock, J P; Zijlstra, W G

    1994-07-01

    A measuring system is described for the determination of oxygen consumption (Vo2) and carbon dioxide production (Vco2) in swimming rats. Vo2 and Vco2 were measured by means of an O2-analyzer (Ametek S3A) and a mass spectrometer (Balzers QMG 511), respectively, combined with a gas flow meter. The measurements were made in a 5-1 metabolic chamber on top of a swimming pool in which a water flow of 0.22 m/s was maintained. The rats were fitted with an indwelling catheter with its tip at the entrance of the right atrium for the repeated determination of energy substrate and hormone concentrations, before, during, and after swimming. The inaccuracy of the Vo2 and Vco2 measurements was 0.18% and 0.31% of the reading, respectively; the imprecision was 2.15% and 2.59%. This high accuracy and precision of the system was attained by measuring room air for 20 s after each 100 s of measuring air from the metabolic chamber, and by using demineralized water in the swimming pool. Vo2 during steady-state swimming was 1.89 +/- 0.06 mmol/kg.min (ca. 60% Vo2max), indicating moderate exercise. Respiratory quotient (RQ), during steady-state exercise, was 0.80 +/- 0.01. Vo2 and RQ resulted in rates for carbohydrate and fat utilization of 15.6 +/- 0.8 and 15.1 +/- 0.7 mg/kg.min, respectively.

  7. Strain effect in epitaxial VO2 thin films grown on sapphire substrates using SnO2 buffer layers

    NASA Astrophysics Data System (ADS)

    Kim, Heungsoo; Bingham, Nicholas S.; Charipar, Nicholas A.; Piqué, Alberto

    2017-10-01

    Epitaxial VO2/SnO2 thin film heterostructures were deposited on m-cut sapphire substrates via pulsed laser deposition. By adjusting SnO2 (150 nm) growth conditions, we are able to control the interfacial strain between the VO2 film and SnO2 buffer layer such that the semiconductor-to-metal transition temperature (TC) of VO2 films can be tuned without diminishing the magnitude of the transition. It is shown that in-plane tensile strain and out-of-plane compressive strain of the VO2 film leads to a decrease of Tc. Interestingly, VO2 films on SnO2 buffer layers exhibit a structural phase transition from tetragonal-like VO2 to tetragonal-VO2 during the semiconductor-to-metal transition. These results suggest that the strain generated by SnO2 buffer provides an effective way for tuning the TC of VO2 films.

  8. Effect of Ferric Carboxymaltose on Exercise Capacity in Patients With Chronic Heart Failure and Iron Deficiency.

    PubMed

    van Veldhuisen, Dirk J; Ponikowski, Piotr; van der Meer, Peter; Metra, Marco; Böhm, Michael; Doletsky, Artem; Voors, Adriaan A; Macdougall, Iain C; Anker, Stefan D; Roubert, Bernard; Zakin, Lorraine; Cohen-Solal, Alain

    2017-10-10

    Iron deficiency is common in patients with heart failure (HF) and is associated with reduced exercise capacity and poor outcomes. Whether correction of iron deficiency with (intravenous) ferric carboxymaltose (FCM) affects peak oxygen consumption [peak VO 2 ], an objective measure of exercise intolerance in HF, has not been examined. We studied patients with systolic HF (left ventricular ejection fraction ≤45%) and mild to moderate symptoms despite optimal HF medication. Patients were randomized 1:1 to treatment with FCM for 24 weeks or standard of care. The primary end point was the change in peak VO 2 from baseline to 24 weeks. Secondary end points included the effect on hematinic and cardiac biomarkers, quality of life, and safety. For the primary analysis, patients who died had a value of 0 imputed for 24-week peak VO 2 . Additional sensitivity analyses were performed to determine the impact of imputation of missing peak VO 2 data. A total of 172 patients with HF were studied and received FCM (n=86) or standard of care (control group, n=86). At baseline, the groups were well matched; mean age was 64 years, 75% were male, mean left ventricular ejection fraction was 32%, and peak VO 2 was 13.5 mL/min/kg. FCM significantly increased serum ferritin and transferrin saturation. At 24 weeks, peak VO 2 had decreased in the control group (least square means -1.19±0.389 mL/min/kg) but was maintained on FCM (-0.16±0.387 mL/min/kg; P =0.020 between groups). In a sensitivity analysis, in which missing data were not imputed, peak VO 2 at 24 weeks decreased by -0.63±0.375 mL/min/kg in the control group and by -0.16±0.373 mL/min/kg in the FCM group; P =0.23 between groups). Patients' global assessment and functional class as assessed by the New York Heart Association improved on FCM versus standard of care. Treatment with intravenous FCM in patients with HF and iron deficiency improves iron stores. Although a favorable effect on peak VO 2 was observed on FCM, compared with standard of care in the primary analysis, this effect was highly sensitive to the imputation strategy for peak VO 2 among patients who died. Whether FCM is associated with an improved outcome in these high-risk patients needs further study. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01394562. © 2017 The Authors.

  9. Effect of Ferric Carboxymaltose on Exercise Capacity in Patients With Chronic Heart Failure and Iron Deficiency

    PubMed Central

    Ponikowski, Piotr; van der Meer, Peter; Metra, Marco; Böhm, Michael; Doletsky, Artem; Voors, Adriaan A.; Macdougall, Iain C.; Anker, Stefan D.; Roubert, Bernard; Zakin, Lorraine; Cohen-Solal, Alain

    2017-01-01

    Background: Iron deficiency is common in patients with heart failure (HF) and is associated with reduced exercise capacity and poor outcomes. Whether correction of iron deficiency with (intravenous) ferric carboxymaltose (FCM) affects peak oxygen consumption [peak VO2], an objective measure of exercise intolerance in HF, has not been examined. Methods: We studied patients with systolic HF (left ventricular ejection fraction ≤45%) and mild to moderate symptoms despite optimal HF medication. Patients were randomized 1:1 to treatment with FCM for 24 weeks or standard of care. The primary end point was the change in peak VO2 from baseline to 24 weeks. Secondary end points included the effect on hematinic and cardiac biomarkers, quality of life, and safety. For the primary analysis, patients who died had a value of 0 imputed for 24-week peak VO2. Additional sensitivity analyses were performed to determine the impact of imputation of missing peak VO2 data. Results: A total of 172 patients with HF were studied and received FCM (n=86) or standard of care (control group, n=86). At baseline, the groups were well matched; mean age was 64 years, 75% were male, mean left ventricular ejection fraction was 32%, and peak VO2 was 13.5 mL/min/kg. FCM significantly increased serum ferritin and transferrin saturation. At 24 weeks, peak VO2 had decreased in the control group (least square means −1.19±0.389 mL/min/kg) but was maintained on FCM (−0.16±0.387 mL/min/kg; P=0.020 between groups). In a sensitivity analysis, in which missing data were not imputed, peak VO2 at 24 weeks decreased by −0.63±0.375 mL/min/kg in the control group and by −0.16±0.373 mL/min/kg in the FCM group; P=0.23 between groups). Patients’ global assessment and functional class as assessed by the New York Heart Association improved on FCM versus standard of care. Conclusions: Treatment with intravenous FCM in patients with HF and iron deficiency improves iron stores. Although a favorable effect on peak VO2 was observed on FCM, compared with standard of care in the primary analysis, this effect was highly sensitive to the imputation strategy for peak VO2 among patients who died. Whether FCM is associated with an improved outcome in these high-risk patients needs further study. Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01394562. PMID:28701470

  10. Microsecond switchable thermal antenna

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ben-Abdallah, Philippe, E-mail: pba@institutoptique.fr; Benisty, Henri; Besbes, Mondher

    2014-07-21

    We propose a thermal antenna that can be actively switched on and off at the microsecond scale by means of a phase transition of a metal-insulator material, the vanadium dioxide (VO{sub 2}). This thermal source is made of a periodically patterned tunable VO{sub 2} nanolayer, which support a surface phonon-polariton in the infrared range in their crystalline phase. Using electrodes properly registered with respect to the pattern, the VO{sub 2} phase transition can be locally triggered by ohmic heating so that the surface phonon-polariton can be diffracted by the induced grating, producing a highly directional thermal emission. Conversely, when heatingmore » less, the VO{sub 2} layers cool down below the transition temperature, the surface phonon-polariton cannot be diffracted anymore so that thermal emission is inhibited. This switchable antenna could find broad applications in the domain of active thermal coatings or in those of infrared spectroscopy and sensing.« less

  11. Combined effects of inspired oxygen, carbon dioxide, and carbon monoxide on oxygen transport and aerobic capacity.

    PubMed

    Crocker, George H; Toth, Balazs; Jones, James H

    2013-09-01

    We hypothesized that breathing hypoxic, hypercapnic, and CO-containing gases together reduces maximal aerobic capacity (Vo2max) as the sum of each gas' individual effect on Vo2max. To test this hypothesis, goats breathed combinations of inspired O2 fraction (FiO2) of 0.06-0.21 and inspired CO2 fraction of 0.00 or 0.05, with and without inspired CO that elevated carboxyhemoglobin fraction (FHbCO) to 0.02-0.45, while running on a treadmill at speeds eliciting Vo2max. Individually, hypoxia and elevated FHbCO decreased fractional Vo2max (FVo2max, fraction of a goat's Vo2max breathing air) in linear, dose-dependent manners; hypercapnia did not change Vo2max. Concomitant hypoxia and elevated FHbCO decreased Vo2max less than the individual gas effects summed, indicating their combined effects on Vo2max are attenuated, fitting the following regression: FVo2max = 4.24 FiO2 + 0.519 FHbCO - 8.22 (FiO2 × FHbCO) + 0.117, (R(2) = 0.965, P < 0.001). The FVo2max correlated highly with total cardiopulmonary O2 delivery, not peripheral diffusing capacity, and with arterial O2 concentration (CaO2), not cardiac output. Hypoxia and elevated FHbCO decreased CaO2 by different mechanisms: hypoxia decreased arterial O2 saturation (SaO2), whereas elevated FHbCO decreased O2 capacitance {concentration of hemoglobin (Hb) available to bind O2 ([Hbavail])}. When breathing hypoxic gas (FiO2 0.12), CaO2 did not change with increasing FHbCO up to 0.30 because higher SaO2 of Hbavail offset decreased [Hbavail] due to the following: 1) hyperventilation with hypoxia and/or elevated FHbCO; 2) increased Hb affinity for O2 due to both Bohr and direct carboxyhemoglobin effects; and 3) the sigmoid relationship between O2 saturation and partial pressure elevating SaO2 more with hypoxia than normoxia.

  12. Porous carbon derived from disposable shaddock peel as an excellent catalyst toward VO2+/VO2+ couple for vanadium redox battery

    NASA Astrophysics Data System (ADS)

    Liu, J.; Wang, Z. A.; Wu, X. W.; Yuan, X. H.; Hu, J. P.; Zhou, Q. M.; Liu, Z. H.; Wu, Y. P.

    2015-12-01

    Functional porous carbon (PC) derived from bio-friendly shaddock peel has been firstly explored as catalyst for vanadium redox flow battery (VRB). The prepared PC is micro-mesoporous with high BET surface area of 882.7 m2 g-1, has some surface oxygen-containing functional groups, and is doped with N and P heteroatoms. These three factors greatly favor the electrochemical reactions of VO2+/VO2+ on the PC modified glass carbon (PC-GC). Compared with the naked GC and graphite modified GC, the PC-GC presents a lower peak separation (66 mV), higher anodic current density (17.1 mA cm-2) and cathodic current density (15.0 mA cm-2). The VRB using PC modified graphite felt (GF) as positive electrode demonstrates an enhanced voltage efficiency of 82.7% at the current density of 60 mA cm-2, and a better rate performance than that from the virginal GF.

  13. A comparison of VO2max and metabolic variables between treadmill running and treadmill skating.

    PubMed

    Koepp, Kriston K; Janot, Jeffrey M

    2008-03-01

    The purpose of this study was to determine differences in VO2max and metabolic variables between treadmill running and treadmill skating. This study also examined VO2max responses during a continuous skating treadmill protocol and a discontinuous skating treadmill protocol. Sixteen male high school hockey players, who had a mean age of 16 +/- 1 years and were of an above-average fitness level, participated in this study. All subjects completed 4 exercise trials: a 1-hour skating treadmill familiarization trial, a treadmill running trial, and 2 randomized skating treadmill trials. Minute ventilation (VE), oxygen consumption VO2), carbon dioxide production VCO2), respiratory exchange ratio (RER), and heart rate were averaged every 15 seconds up to VO2max for each exercise test. The results showed that there was a significant difference (P < 0.05) for VO2max (mL.kg.min) and maximal VCO2 (L.min) between the running treadmill protocol and discontinuous skating treadmill protocol. There was also a significant difference for maximal RER between the discontinuous and continuous skating treadmill protocol and between the discontinuous skating treadmill protocol and running treadmill protocol. In conclusion, the running treadmill elicited a greater VO2max (mL.kg.min) than the skating treadmill did, but when it comes to specificity of ice skating, the skating treadmill may be ideal. Also, there was no significant difference between the discontinuous and continuous skating treadmill protocols. Therefore, a continuous protocol is possible on the skating treadmill without compromising correct skating position and physiologic responses. However, the continuous skating treadmill protocol should undergo validation before other scientists, coaches, and strength and conditioning professionals can apply it correctly.

  14. Exercise economy in skiing and running

    PubMed Central

    Losnegard, Thomas; Schäfer, Daniela; Hallén, Jostein

    2014-01-01

    Substantial inter-individual variations in exercise economy exist even in highly trained endurance athletes. The variation is believed to be determined partly by intrinsic factors. Therefore, in the present study, we compared exercise economy in V2-skating, double poling, and uphill running. Ten highly trained male cross-country skiers (23 ± 3 years, 180 ± 6 cm, 75 ± 8 kg, VO2peak running: 76.3 ± 5.6 mL·kg−1·min−1) participated in the study. Exercise economy and VO2peak during treadmill running, ski skating (V2 technique) and double poling were compared based on correlation analysis. There was a very large correlation in exercise economy between V2-skating and double poling (r = 0.81) and large correlations between V2-skating and running (r = 0.53) and double poling and running (r = 0.58). There were trivial to moderate correlations between exercise economy and the intrinsic factors VO2peak (r = 0.00–0.23), cycle rate (r = 0.03–0.46), body mass (r = −0.09–0.46) and body height (r = 0.11–0.36). In conclusion, the inter-individual variation in exercise economy could be explained only moderately by differences in VO2peak, body mass and body height. Apparently other intrinsic factors contribute to the variation in exercise economy between highly trained subjects. PMID:24478718

  15. Effects of high-intensity interval training on cardiometabolic risk factors in overweight/obese women

    PubMed Central

    Smith-Ryan, Abbie E.; Trexler, Eric T.; Wingfield, Hailee; Blue, Malia N.M.

    2016-01-01

    The purpose of this study was to evaluate two practical interval training protocols on cardiorespiratory fitness, lipids, and body composition in overweight/obese women. Thirty women (mean ± SD; Weight: 88.1 ± 15.9 kg; BMI: 32.0 ± 6.0 kg·m2) were randomly assigned to ten 1-minute high-intensity intervals (90%VO2peak, 1min recovery), or five 2-minute high-intensity intervals (80-100% VO2peak, 1 min recovery), or control. Peak oxygen uptake (VO2peak), peak power output, body composition, and fasting blood lipids were evaluated before and after 3 weeks of training, completed 3 days per week. Results from ANCOVA analyses demonstrated no significant training group differences for any primary variables (p>0.05). When training groups were collapsed, 1MIN and 2MIN resulted in a significant increase in peak power output (∆18.9 ± 8.5 watts; p=0.014) and time to exhaustion (∆55.1 ± 16.4 sec; p=0.001); non-significant increase in VO2peak (∆2.36 ± 1.34 ml·kg−1·min−1; p=0.185); and a significant decrease in fat mass (∆−1.96 ± 0.99kg; p=0.011). Short-term interval exercise training may be effective for decreasing fat mass and improving exercise tolerance in overweight and obese women. PMID:26934687

  16. Significance of the velocity at VO2max and time to exhaustion at this velocity.

    PubMed

    Billat, L V; Koralsztein, J P

    1996-08-01

    In 1923, Hill and Lupton pointed out that for Hill himself, 'the rate of oxygen intake due to exercise increases as speed increases, reaching a maximum for the speeds beyond about 256 m/min. At this particular speed, for which no further increases in O2 intake can occur, the heart, lungs, circulation, and the diffusion of oxygen to the active muscle-fibres have attained their maximum activity. At higher speeds the requirement of the body for oxygen is far higher but cannot be satisfied, and the oxygen debt continuously increases'. In 1975, this minimal velocity which elicits maximal oxygen uptake (VO2max) was called 'critical speed' and was used to measure the maximal aerobic capacity (max Eox), i.e. the total oxygen consumed at VO2max. This should not be confused with the term 'critical power' which is closes to the power output at the 'lactate threshold'. In 1984, the term 'velocity at VO2max' and the abbreviation 'vVO2max' was introduced. It was reported that vVO2max is a useful variable that combines VO2max and economy into a single factor which can identify aerobic differences between various runners or categories of runners. vVO2max explained individual differences in performance that VO2max or running economy alone did not. Following that, the concept of a maximal aerobic running velocity (Vamax in m/sec) was formulated. This was a running velocity at which VO2max occurred and was calculated as the ratio between VO2max (ml/kg/min) minus oxygen consumption at rest, and the energy cost of running (ml/kg/sec). There are many ways to determine the velocity associated with VO2max making it difficult to compare maintenance times. In fact, the time to exhaustion (tlim) at vVO2max is reproducible in an individual, however, there is a great variability among individuals with a low coefficient of variation for vVO2max. For an average value of about 6 minutes, the coefficient of variation is about 25%. It seems that the lactate threshold which is correlated with the tlim at vVO2max can explain this difference among individuals, the role of the anaerobic contribution being significant. An inverse relationship has been found between tlim at vVO2max and VO2max, and a positive one between vVO2max and the velocity at the lactate threshold expressed as a fraction of vVO2max. These results are similar for different sports (e.g. running, cycling, kayaking, swimming). It seems that the real time spent at VO2max is significantly different from an exhaustive run at a velocity close to vVO2max (105% vVO2max). However, the minimal velocity which elicits VO2max, and the tlim at this velocity appear to convey valuable information when analysing a runner's performance over 1500m to a marathon.

  17. The effect of Iron Supplying on VO2 MAX and Haematology Parameter on Menstrual Woman

    NASA Astrophysics Data System (ADS)

    Nailuvar Sinaga, Rika; Sari Harahap, Novita; Mediyana Sari, Rima

    2018-03-01

    One of the supporting factors to have good aerobic endurance requires high VO2 max levels supported by good quality and quantity level of Haematology parameter especially such as erythrocytes, hematocrit and hemoglobin. One of the components in hemoglobin is iron which functions as theoxygen transport to parts of all body required in the process of metabolism. The objective of this research was to find out the difference between VO2 Max and Haematology parameter between iron supplying and no iron supplyingonmenstrual woman. The type of this research is quasi experimental research with non-randomized control group Pretest-Postest Design. The subjectsarethe studentsat faculty of Sports Sciences, Medan State University with the criteria of female gender, monthly regular menstrual cycle, having the level of health and the level of training, willing to be a sample by filling out informed consent. The total number of research subjectsis twenty students, divided into two groups namely the treatment group and the control group. The hematology parameter was measuredby Haemotology analyzer and VO2 Max was measured by multi-stage run. The result showed that there was a significant effect of iron supplyingon the increase of erythrocyte level on menstrual women, hemotocrit, haemoglobin and an increase in VO2 Max. Iron supplying on menstrual woman has the effect on the increase of erythrocyte, hematocrit, hemoglobin level and VO2 Max

  18. Effect of Element Substitution at V site on Thermoelectric Properties of Aurivillius Phase Bi2VO5.5

    NASA Astrophysics Data System (ADS)

    Kohri, Hitoshi; Yagasaki, Takayoshi

    2016-10-01

    Thermoelectric oxides are suitable at the high temperature range because of chemical stability. Aurivillius compounds are bismuth layered oxides, and known as oxygen ion conductors. The Aurivillius compounds consist of Perovskite layers and Bi-O layers. It is expected that nano-layered structure shows high Seebeck coefficients due to the quantum confinement of carriers in Perovskite layers. It was reported that the Seebeck coefficient of hot pressed specimens for Aurivillius phase Bi2VO5.5 was a high value of -28.3 mVK-1 at 1010 K, and the electrical resistivity of one was also a high value of 0.033 Ωm at 1010 K. In this paper, the effect of element substitution at the V site on thermoelectric properties of Aurivillius phase Bi2VO5.5 was investigated. Bi2V1- x M x O5.5 (M = Cr, Mo, W x = 0, 0.05, 0.1, 0.2) were prepared by solid-state reaction. The electrical resistivity of Cr-substituted specimens were indicated at larger values than the ones for unsubstituted specimens over the measurement temperature range. The resistivity above 800 K was reduced by substitution of W or Mo. W as a substituted element was effective for reducing the thermal conductivity of Bi2VO5.5. The maximum value of the dimensionless figure of merit ZT was 0.05 at 799 K for Bi2V0.8Mo0.2O5.5 and at 902 K for Bi2V0.8W0.1O5.5. The maximum ZT of an unsubstituted sample was 0.02 at 993 K. From these results, it was found that tungsten or molybdenum substitution was effective to improve ZT for Aurivillius phase Bi2VO5.5.

  19. Determining the role of TiO/VO in hot exoplanet atmospheres

    NASA Astrophysics Data System (ADS)

    Evans, Thomas

    2016-10-01

    The role of TiO and VO in ultra hot (>2000K) gas giant atmospheres is a major unresolved issue in the exoplanet field. At these temperatures, TiO and VO are known to be important absorbers in the atmospheres of M/L dwarfs and have been theorized to play an important role in irradiated gas giants. To date, however, TiO/VO has not been securely detected in a planetary atmosphere, despite numerous searches. One possibility is that the upper atmospheres of highly irradiated planets are typically depleted of TiO/VO by cold-trapping at lower altitudes or rain-out on the relatively cool nightside. Using WFC3 G141 and ground-based photometry, we have recently published a transmission spectrum for WASP-121b (T~2400K) showing new evidence for absorption by TiO/VO. Our observations also yielded a high confidence (5.4 sigma) detection of the 1.4 micron H2O absorption band. The TiO/VO claim, however, remains tentative, as it currently hinges upon broadband photometry measurements obtained from the ground at relatively low signal-to-noise. If TiO/VO is present it will have significant implications for the overall physics and chemistry of the atmosphere, including the likely production of a strong thermal inversion in the upper atmosphere. I will describe the follow-up observations we are currently pursuing in order to confirm or rule out TiO/VO in the atmosphere of WASP-121b and in doing so address a long-standing mystery of exoplanet atmospheres.

  20. Effects of high aerobic intensity training in patients with schizophrenia: a controlled trial.

    PubMed

    Heggelund, Jørn; Nilsberg, Geir E; Hoff, Jan; Morken, Gunnar; Helgerud, Jan

    2011-09-01

    Patients with schizophrenia have a high risk of cardiovascular disease (CVD). High aerobic intensity training (HIT) improve peak oxygen uptake (VO(2peak)), net mechanical efficiency of walking and risk factors for CVD but has not been investigated in patients with schizophrenia. To investigate effects from HIT on VO(2peak), net mechanical efficiency of walking and risk factors for CVD in patients with schizophrenia. 25 inpatients (F20-29, ICD-10) were allocated to either HIT or playing computer games (CG), 3 days per week for 8 weeks. HIT consisted of 4 × 4-min intervals with 3-min break periods, at 85-95% and 70% of peak heart rate, respectively. 12 and seven patients completed HIT and CG, respectively. The baseline VO(2peak) in both groups combined (n = 19) was 36.8 ± 8.2 ml/kg/min and 3.12 ± 0.55 l/min. The HIT group improved VO(2peak) by 12% from 3.17 ± 0.59 to 3.56 ± 0.68 l/min (P < 0.001), more than the CG group (P = 0.014). Net mechanical efficiency of walking improved by 12% in the HIT group from 19.8 ± 3.0% to 22.2 ± 4.5% (P = 0.005), more than the CG group (P = 0.031). The psychiatric symptoms, expressed as the Positive and Negative Syndrome Scale (PANSS) and the Calgary Depression Scale for Schizophrenia (CDSS), did not improve in either group. VO(2peak) and net mechanical efficiency of walking improved significantly by 8 weeks of HIT. HIT should be included in rehabilitation in order to improve physical capacity and contribute risk reduction of CVD.

  1. Dissimilar Physiological and Perceptual Responses Between Sprint Interval Training and High-Intensity Interval Training.

    PubMed

    Wood, Kimberly M; Olive, Brittany; LaValle, Kaylyn; Thompson, Heather; Greer, Kevin; Astorino, Todd A

    2016-01-01

    High-intensity interval training (HIIT) and sprint interval training (SIT) elicit similar cardiovascular and metabolic adaptations vs. endurance training. No study, however, has investigated acute physiological changes during HIIT vs. SIT. This study compared acute changes in heart rate (HR), blood lactate concentration (BLa), oxygen uptake (VO2), affect, and rating of perceived exertion (RPE) during HIIT and SIT. Active adults (4 women and 8 men, age = 24.2 ± 6.2 years) initially performed a VO2max test to determine workload for both sessions on the cycle ergometer, whose order was randomized. Sprint interval training consisted of 8 bouts of 30 seconds of all-out cycling at 130% of maximum Watts (Wmax). High-intensity interval training consisted of eight 60-second bouts at 85% Wmax. Heart rate, VO2, BLa, affect, and RPE were continuously assessed throughout exercise. Repeated-measures analysis of variance revealed a significant difference between HIIT and SIT for VO2 (p < 0.001), HR (p < 0.001), RPE (p = 0.03), and BLa (p = 0.049). Conversely, there was no significant difference between regimens for affect (p = 0.12). Energy expenditure was significantly higher (p = 0.02) in HIIT (209.3 ± 40.3 kcal) vs. SIT (193.5 ± 39.6 kcal). During HIIT, subjects burned significantly more calories and reported lower perceived exertion than SIT. The higher VO2 and lower BLa in HIIT vs. SIT reflected dissimilar metabolic perturbation between regimens, which may elicit unique long-term adaptations. If an individual is seeking to burn slightly more calories, maintain a higher oxygen uptake, and perceive less exertion during exercise, HIIT is the recommended routine.

  2. A randomized waitlist-controlled pilot trial of voice over Internet protocol-delivered behavior therapy for youth with chronic tic disorders.

    PubMed

    Ricketts, Emily J; Goetz, Amy R; Capriotti, Matthew R; Bauer, Christopher C; Brei, Natalie G; Himle, Michael B; Espil, Flint M; Snorrason, Ívar; Ran, Dagong; Woods, Douglas W

    2016-04-01

    Comprehensive Behavioral Intervention for Tics (CBIT) has been shown to be efficacious for chronic tic disorders (CTDs), but utilization is limited by a lack of treatment providers and perceived financial and time burden of commuting to treatment. A promising alternative to in-person delivery is voice over Internet protocol (VoIP), allowing for remote, real-time treatment delivery to patients' homes. However, little is known about the effectiveness of VoIP for CTDs. Therefore, the present study examined the preliminary efficacy, feasibility, and acceptability of VoIP-delivered CBIT (CBIT-VoIP). Twenty youth (8-16 years) with CTDs participated in a randomized, waitlist-controlled pilot trial of CBIT-VoIP. The main outcome was pre- to post-treatment change in clinician-rated tic severity (Yale Global Tic Severity Scale). The secondary outcome was clinical responder rate (Clinical Global Impressions - Improvement Scale), assessed using ratings of 'very much improved' or 'much improved' indicating positive treatment response. Intention-to-treat analyses with the last observation carried forward were performed. At post-treatment (10-weeks), significantly greater reductions in clinician-rated, (F(1,18) = 3.05, p < 0.05, partial η(2 )= 0.15), and parent-reported tic severity, (F(1,18) = 6.37, p < 0.05, partial η(2 )= 0.26) were found in CBIT-VoIP relative to waitlist. One-third (n = 4) of those in CBIT-VoIP were considered treatment responders. Treatment satisfaction and therapeutic alliance were high. CBIT can be delivered via VoIP with high patient satisfaction, using accessible, low-cost equipment. CBIT-VoIP was generally feasible to implement, with some audio and visual challenges. Modifications to enhance treatment delivery are suggested. © The Author(s) 2015.

  3. Criterion validation of two submaximal aerobic fitness tests, the self-monitoring Fox-walk test and the Åstrand cycle test in people with rheumatoid arthritis.

    PubMed

    Nordgren, Birgitta; Fridén, Cecilia; Jansson, Eva; Österlund, Ted; Grooten, Wilhelmus Johannes; Opava, Christina H; Rickenlund, Anette

    2014-09-17

    Aerobic capacity tests are important to evaluate exercise programs and to encourage individuals to have a physically active lifestyle. Submaximal tests, if proven valid and reliable could be used for estimation of maximal oxygen uptake (VO2max). The purpose of the study was to examine the criterion-validity of the submaximal self-monitoring Fox-walk test and the submaximal Åstrand cycle test against a maximal cycle test in people with rheumatoid arthritis (RA). A secondary aim was to study the influence of different formulas for age predicted maximal heart rate when estimating VO2max by the Åstrand test. Twenty seven subjects (81% female), mean (SD) age 62 (8.1) years, diagnosed with RA since 17.9 (11.7) years, participated in the study. They performed the Fox-walk test (775 meters), the Åstrand test and the maximal cycle test (measured VO2max test). Pearson's correlation coefficients were calculated to determine the direction and strength of the association between the tests, and paired t-tests were used to test potential differences between the tests. Bland and Altman methods were used to assess whether there was any systematic disagreement between the submaximal tests and the maximal test. The correlation between the estimated and measured VO2max values were strong and ranged between r = 0.52 and r = 0.82 including the use of different formulas for age predicted maximal heart rate, when estimating VO2max by the Åstrand test. VO2max was overestimated by 30% by the Fox-walk test and underestimated by 10% by the Åstrand test corrected for age. When the different formulas for age predicted maximal heart rate were used, the results showed that two formulas better predicted maximal heart rate and consequently a more precise estimation of VO2max. Despite the fact that the Fox-walk test overestimated VO2max substantially, the test is a promising method for self-monitoring VO2max and further development of the test is encouraged. The Åstrand test should be considered as highly valid and feasible and the two newly developed formulas for predicting maximal heart rate according to age are preferable to use when estimating VO2max by the Åstrand test.

  4. Video-Only Cardiopulmonary Resuscitation Education for High-Risk Families Before Hospital Discharge: A Multicenter Pragmatic Trial.

    PubMed

    Blewer, Audrey L; Putt, Mary E; Becker, Lance B; Riegel, Barbara J; Li, Jiaqi; Leary, Marion; Shea, Judy A; Kirkpatrick, James N; Berg, Robert A; Nadkarni, Vinay M; Groeneveld, Peter W; Abella, Benjamin S

    2016-11-01

    Cardiopulmonary resuscitation (CPR) training rates in the United States are low, highlighting the need to develop CPR educational approaches that are simpler, with broader dissemination potential. The minimum training required to ensure long-term skill retention remains poorly characterized. We compared CPR skill retention among laypersons randomized to training with video-only (VO; no manikin) with those trained with a video self-instruction kit (VSI; with manikin). We hypothesized that VO training would be noninferior to the VSI approach with respect to chest compression (CC) rate. We performed a prospective, cluster randomized trial of CPR education for family members of patients with high-risk cardiac conditions on hospital cardiac units, using a multicenter pragmatic design. Eight hospitals were randomized to offer either VO or VSI training before discharge using volunteer trainers. CPR skills were assessed 6 months post training. Mean CC rate among those trained with VO compared with those trained with VSI was assessed with a noninferiority margin set at 8 CC per min; as a secondary outcome, mean differences in CC depth were assessed. From February 2012 to May 2015, 1464 subjects were enrolled and 522 subjects completed a skills assessment. The mean CC rates were 87.7 (VO) CC per min and 89.3 (VSI) CC per min; we concluded noninferiority for VO based on a mean difference of -1.6 (90% confidence interval, -5.2 to 2.1). The mean CC depth was 40.2 mm (VO) and 45.8 mm (VSI) with a mean difference of -5.6 (95% confidence interval, -7.6 to -3.7). Results were similar after multivariate regression adjustment. In this large, prospective trial of CPR skill retention, VO training yielded a noninferior difference in CC rate compared with VSI training. CC depth was greater in the VSI group. These findings suggest a potential trade-off in efforts for broad dissemination of basic CPR skills; VO training might allow for greater scalability and dissemination, but with a potential reduction in CC depth. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01514656. © 2016 American Heart Association, Inc.

  5. Pulmonary and leg VO2 during submaximal exercise: implications for muscular efficiency

    NASA Technical Reports Server (NTRS)

    Poole, D. C.; Gaesser, G. A.; Hogan, M. C.; Knight, D. R.; Wagner, P. D.

    1992-01-01

    Insights into muscle energetics during exercise (e.g., muscular efficiency) are often inferred from measurements of pulmonary gas exchange. This procedure presupposes that changes of pulmonary O2 (VO2) associated with increases of external work reflect accurately the increased muscle VO2. The present investigation addressed this issue directly by making simultaneous determinations of pulmonary and leg VO2 over a range of work rates calculated to elicit 20-90% of maximum VO2 on the basis of prior incremental (25 or 30 W/min) cycle ergometry. VO2 for both legs was calculated as the product of twice one-leg blood flow (constant-infusion thermodilution) and arteriovenous O2 content difference across the leg. Measurements were made 3-5 min after each work rate imposition to avoid incorporation of the VO2 slow component above the lactate threshold. For all 17 subjects, the slope of pulmonary VO2 (9.9 +/- 0.2 ml O2.W-1.min-1) was not different (P greater than 0.05) from that for leg VO2 (9.2 +/- 0.6 ml O2.W-1.min-1). Estimation of "delta" efficiency (i.e., delta work accomplished divided by delta energy expended, calculated from slope of VO2 vs. work rate and a caloric equivalent for O2 of 4.985 cal/ml) using pulmonary VO2 measurements (29.1 +/- 0.6%) was likewise not significantly different (P greater than 0.05) from that made using leg VO2 measurements (33.7 +/- 2.4%). These data suggest that the net VO2 cost of metabolic "support" processes outside the exercising legs changes little over a relatively broad range of exercise intensities. Thus, under the conditions of this investigation, changes of VO2 measured from expired gas reflected closely those occurring within the exercising legs.

  6. Enhancement of electrical transport modulation in epitaxial VO2 nanowire field-effect transistor

    NASA Astrophysics Data System (ADS)

    Tanaka, Hidekazu; Chikanari, Masashi; Kanki, Teruo

    Strongly correlated system vanadium dioxide VO2 has attracted widespread concerns from researchers as an exciting electronic material, due to the many intriguing features, especially metal-insulator transition (MIT) in vicinity of room temperature. In this work, we report a diverse geometry for high sensitivity in the transport modulation. By taking advantage of nanometer scale channel, instead of thin film channels, we demonstrated the enhancement of resistance modulation by applying gate voltage. Also we designed the insulating gate, consisting of high-k material Ta2O5/organic polymer parylene-C hybrid insulator. Such as this hybrid gate dielectric would effectively reduce interface deterioration of active channel oxide and provide sufficient carrier density. Moreover, benefited from the nanometer scale channel, the VO2 nanowire-based transistor could deliver a resistance modulation ratio over 8.5%, which are about 10 folds higher than that of the film case. Furthermore, this result is explained that in spite of the stronger field distribution in the edge parts of VO2 nanowire channel yielded little carrier density, the generated mobility modulation would biquadratic increase according to Brinkman-Rice picture as new finding.

  7. VO2 attained during treadmill running: the influence of a specialist (400-m or 800-m) event.

    PubMed

    James, David V B; Sandals, Leigh E; Draper, Stephen B; Maldonado-Martin, Sara; Wood, Dan M

    2007-06-01

    Previously it has been observed that, in well-trained 800-m athletes, VO2max is not attained during middle-distance running events on a treadmill, even when a race-type pacing strategy is adopted. Therefore, the authors investigated whether specialization in a particular running distance (400-m or 800-m) influences the VO2 attained during running on a treadmill. Six 400-m and six 800-m running specialists participated in the study.A 400-m trial and a progressive test to determine VO2max were completed in a counterbalanced order. Oxygen uptakes attained during the 400-m trial were compared to examine the influence of specialist event. A VO2 plateau was observed in all participants for the progressive test, demonstrating the attainment of VO2max. The VO2max values were 56.2 +/- 4.7 and 69.3 +/- 4.5 mL x kg-1 x min-1 for the 400-m- and 800-m-event specialists, respectively (P = .0003). Durations for the 400-m trial were 55.1 +/- 4.2 s and 55.8 +/- 2.3 s for the 400-m- and 800-m-event specialists, respectively. The VO2 responses achieved were 93.1% +/- 2.0% and 85.7% +/- 3.0% VO2max for the 400-m- and 800-m-event specialists, respectively (P = .001). These results demonstrate that specialist running events do appear to influence the percentage of VO2max achieved in the 400-m trial, with the 800-m specialists attaining a lower percentage of VO2max than the 400-m specialists. The 400-m specialists appear to compensate for a lower VO2max by attaining a higher percentage VO2max during a 400-m trial.

  8. Flowable Conducting Particle Networks in Redox-Active Electrolytes for Grid Energy Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hatzell, K. B.; Boota, M.; Kumbur, E. C.

    2015-01-01

    This study reports a new hybrid approach toward achieving high volumetric energy and power densities in an electrochemical flow capacitor for grid energy storage. The electrochemical flow capacitor suffers from high self-discharge and low energy density because charge storage is limited to the available surface area (electric double layer charge storage). Here, we examine two carbon materials as conducting particles in a flow battery electrolyte containing the VO2+/VO2+ redox couple. Highly porous activated carbon spheres (CSs) and multi-walled carbon nanotubes (MWCNTs) are investigated as conducting particle networks that facilitate both faradaic and electric double layer charge storage. Charge storage contributionsmore » (electric double layer and faradaic) are distinguished for flow-electrodes composed of MWCNTs and activated CSs. A MWCNT flow-electrode based in a redox-active electrolyte containing the VO2+/VO2+ redox couple demonstrates 18% less self-discharge, 10 X more energy density, and 20 X greater power densities (at 20 mV s-1) than one based on a non-redox active electrolyte. Furthermore, a MWCNT redox-active flow electrode demonstrates 80% capacitance retention, and >95% coulombic efficiency over 100 cycles, indicating the feasibility of utilizing conducting networks with redox chemistries for grid energy storage.« less

  9. Flowable conducting particle networks in redox-active electrolytes for grid energy storage

    DOE PAGES

    Hatzell, K. B.; Boota, M.; Kumbur, E. C.; ...

    2015-01-09

    This paper reports a new hybrid approach toward achieving high volumetric energy and power densities in an electrochemical flow capacitor for grid energy storage. The electrochemical flow capacitor suffers from high self-discharge and low energy density because charge storage is limited to the available surface area (electric double layer charge storage). Here, we examine two carbon materials as conducting particles in a flow battery electrolyte containing the VO 2+/VO 2 + redox couple. Highly porous activated carbon spheres (CSs) and multi-walled carbon nanotubes (MWCNTs) are investigated as conducting particle networks that facilitate both faradaic and electric double layer charge storage.more » Charge storage contributions (electric double layer and faradaic) are distinguished for flow-electrodes composed of MWCNTs and activated CSs. A MWCNT flow-electrode based in a redox-active electrolyte containing the VO 2+/VO 2 + redox couple demonstrates 18% less self-discharge, 10 X more energy density, and 20 X greater power densities (at 20 mV s -1) than one based on a non-redox active electrolyte. Additionally, a MWCNT redox-active flow electrode demonstrates 80% capacitance retention, and >95% coulombic efficiency over 100 cycles, indicating the feasibility of utilizing conducting networks with redox chemistries for grid energy storage.« less

  10. Superior high-rate capability of Na3(VO(0.5))2(PO4)2F2 nanoparticles embedded in porous graphene through the pseudocapacitive effect.

    PubMed

    Xiang, Xingde; Lu, Qiongqiong; Han, Mo; Chen, Jun

    2016-03-04

    Na3(VO(0.5))2(PO4)2F2 nanoparticles embedded in porous graphene have been reported as a superior high-rate cathode material for sodium-ion batteries, exhibiting an excellent electrochemical performance with a high reversible capacity of 100 mA h g(-1) at 1 C, 77 mA h g(-1) at 50 C, and a capacity retention of 73% after 1000 cycles at 50 C. In particular, a significant contribution of the pseudocapacitive effect to the Na-storage capacity has been found for the first time.

  11. Vanadium and cancer treatment: antitumoral mechanisms of three oxidovanadium(IV) complexes on a human osteosarcoma cell line.

    PubMed

    León, I E; Butenko, N; Di Virgilio, A L; Muglia, C I; Baran, E J; Cavaco, I; Etcheverry, S B

    2014-05-01

    We report herein the antitumor actions of three oxidovanadium(IV) complexes on MG-63 human osteosarcoma cell line. The three complexes: VO(oda), VO(oda)bipy and VO(oda)phen (oda=oxodiacetate), caused a concentration dependent inhibition of cell viability. The antiproliferative action of VO(oda)phen could be observed in the whole range of concentrations (at 2.5 μM), while VO(oda)bipy and VO(oda) showed a decrease of cell viability only at higher concentrations (at 50 and 75 μM, respectively) (p<0.01). Moreover, VO(oda)phen caused a decrease of lysosomal and mitochondrial activities at 2.5 μM, while VO(oda) and VO(oda)bipy affected neutral red uptake and mitochondrial metabolism at 50 μM (p<0.01). On the other hand, no DNA damage studied by the Comet assay could be observed in MG-63 cells treated with VO(oda) at 2.5-10 μM. Nevertheless, VO(oda)phen and VO(oda)bipy induced DNA damage at 2.5 and 10 μM, respectively (p<0.01). The generation of reactive oxygen species increased at 10 μM of VO(oda)phen and only at 100 μM of VO(oda) and VO(oda)bipy (p<0.01). Besides, VO(oda)phen and VO(oda)bipy triggered apoptosis as determined by externalization of the phosphatidylserine. The determination of DNA cleavage by agarose gel electrophoresis showed that the ability of VO(oda)(bipy) is similar to that of VO(oda), while VO(oda)(phen) showed the highest nuclease activity in this series. Overall, our results showed a good relationship between the bioactivity of the complexes and their structures since VO(oda)phen presented the most potent antitumor action in human osteosarcoma cells followed by VO(oda)bipy and then by VO(oda) according to the number of intercalating heterocyclic moieties. © 2013.

  12. Impact of High-intensity Intermittent and Moderate-intensity Continuous Exercise on Autonomic Modulation in Young Men.

    PubMed

    Cabral-Santos, C; Giacon, T R; Campos, E Z; Gerosa-Neto, J; Rodrigues, B; Vanderlei, L C M; Lira, F S

    2016-06-01

    The aim of this study was to compare heart rate variability (HRV) recovery after two iso-volume (5 km) exercises performed at different intensities. 14 subjects volunteered (25.17±5.08 years; 74.7±6.28 kg; 175±0.05 cm; 59.56±5.15 mL·kg(-1)·min(-1)) and after determination of peak oxygen uptake (VO2Peak) and the speed associated with VO2Peak (sVO2Peak), the subjects completed 2 random experimental trials: high-intensity exercise (HIE - 1:1 at 100% sVO2Peak), and moderate-intensity continuous exercise (MIE - 70% sVO2Peak). HRV and RR intervals were monitored before, during and after the exercise sessions together with, the HRV analysis in the frequency domains (high-frequency - HF: 0.15 to 0.4 Hz and low-frequency - LF: 0.04 to 0.15 Hz components) and the ratio between them (LF/HF). Statistical analysis comparisons between moments and between HIE and MIE were performed using a mixed model. Both exercise sessions modified LFlog, HFlog, and LF/HF (F=16.54, F=19.32 and F=5.17, p<0.05, respectively). A group effect was also found for LFlog (F=23.91, p<0.05), and HFlog (F=57.55, p< 0.05). LF/HF returned to resting value 15 min after MIE exercise and 20 min after HIE exercise. This means that the heavy domain (aerobic and anaerobic threshold) induces dissimilar autonomic modification in physically active subjects. Both HIE and MIE modify HRV, and generally HIE delays parasympathetic autonomic modulation recovery after iso-volume exercise. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Anisotropic vanadium dioxide sculptured thin films with superior thermochromic properties.

    PubMed

    Sun, Yaoming; Xiao, Xiudi; Xu, Gang; Dong, Guoping; Chai, Guanqi; Zhang, Hua; Liu, Pengyi; Zhu, Hanmin; Zhan, Yongjun

    2013-09-25

    VO2 (M) STF through reduction of V2O5 STF was prepared. The results illustrate that V2O5 STF can be successfully obtained by oblique angle thermal evaporation technique. After annealing at 550 °C/3 min, the V2O5 STF deposited at 85° can be easily transformed into VO2 STF with slanted columnar structure and superior thermochromic properties. After deposition SiO2 antireflective layer, Tlum of VO2 STF is enhanced 26% and ΔTsol increases 60% compared with that of normal VO2 thin films. Due to the anisotropic microstructure of VO2 STF, angular selectivity transmission of VO2 STF is observed and the solar modulation ability is further improved from 7.2% to 8.7% when light is along columnar direction. Moreover, the phase transition temperature of VO2 STF can be depressed into 54.5 °C without doping. Considering the oblique incidence of sunlight on windows, VO2 STF is more beneficial for practical application as smart windows compared with normal homogenous VO2 thin films.

  14. Anisotropic vanadium dioxide sculptured thin films with superior thermochromic properties

    PubMed Central

    Sun, Yaoming; Xiao, Xiudi; Xu, Gang; Dong, Guoping; Chai, Guanqi; Zhang, Hua; Liu, Pengyi; Zhu, Hanmin; Zhan, Yongjun

    2013-01-01

    VO2 (M) STF through reduction of V2O5 STF was prepared. The results illustrate that V2O5 STF can be successfully obtained by oblique angle thermal evaporation technique. After annealing at 550°C/3 min, the V2O5 STF deposited at 85° can be easily transformed into VO2 STF with slanted columnar structure and superior thermochromic properties. After deposition SiO2 antireflective layer, Tlum of VO2 STF is enhanced 26% and ΔTsol increases 60% compared with that of normal VO2 thin films. Due to the anisotropic microstructure of VO2 STF, angular selectivity transmission of VO2 STF is observed and the solar modulation ability is further improved from 7.2% to 8.7% when light is along columnar direction. Moreover, the phase transition temperature of VO2 STF can be depressed into 54.5°C without doping. Considering the oblique incidence of sunlight on windows, VO2 STF is more beneficial for practical application as smart windows compared with normal homogenous VO2 thin films. PMID:24067743

  15. The 1-mile walk test is a valid predictor of VO(2max) and is a reliable alternative fitness test to the 1.5-mile run in U.S. Air Force males.

    PubMed

    Weiglein, Laura; Herrick, Jeffery; Kirk, Stacie; Kirk, Erik P

    2011-06-01

    The purpose of this study was to assess the validity of the 1-mile walk (Rockport Walk Test) as a predictor of VO(2max) and determine whether the 1-mile walk is a reliable alternative to the 1.5-mile run in moderately fit to highly fit U.S. Air Force males. Twenty-four (33.0 +/- 1.5 years) males completed a maximal treadmill VO(2max) (50.3 +/- 1.4 mL/ kg/min), 1-mile walk, and 1.5-mile run. For the 1-mile walk, there were no significant differences between measured and predicted VO(2max) (p = 0.177, r = 0.817). There were no significant differences (p = 0.573) between points scored in the Air Force Fitness Test for the 1-mile walk and 1.5-mile run tests. In conclusion, the 1-mile walk test is a valid predictor of VO(2max) and can be used as an alternative fitness test to the 1.5-mile run in assessing cardiovascular fitness in Air Force males.

  16. Electrolysis-induced protonation of VO2 thin film transistor for the metal-insulator phase modulation

    NASA Astrophysics Data System (ADS)

    Katase, Takayoshi; Endo, Kenji; Ohta, Hiromichi

    2016-02-01

    Compared to state-of-the-art modulation techniques, protonation is the most ideal to control the electrical and optical properties of transition metal oxides (TMOs) due to its intrinsic non-volatile operation. However, the protonation of TMOs is not typically utilized for solid-state devices because of imperative high-temperature annealing treatment in hydrogen source. Although one solution for room temperature (RT) protonation of TMOs is liquid-phase electrochemistry, it is unsuited for practical purposes due to liquid-leakage problem. Herein we demonstrate solid-state RT-protonation of vanadium dioxide (VO2), which is a well-known thermochromic TMO. We fabricated the three terminal thin-film-transistor structure on an insulating VO2 film using a water-infiltrated nanoporous glass, which serves as a solid electrolyte. For gate voltage application, water electrolysis and protonation/deprotonation of VO2 film surface occurred, leading to reversible metal-insulator phase conversion of ~11-nm-thick VO2 layer. The protonation was clearly accompanied by the structural change from an insulating monoclinic to a metallic tetragonal phase. Present results offer a new route for the development of electro-optically active solid-state devices with TMO materials by engineering RT protonation.

  17. Intraosseous Erythropoietin for Acute Tissue Protection in Battlefield Casualties Suffering Hypovolemic Shock

    DTIC Science & Technology

    2015-07-01

    excess deficit, likely related to a flow dependent reduction in systemic oxygen consumption (VO2), but this effect was transient attain- ing values... oxygen delivery index; VO2, systemic oxygen consumption index; Hct, hematocrit, PaCO2, arterial PCO2; PETCO2, end-tidal PCO2. Table S1: Effect of...response that enabled maintaining oxygen consumption close to baseline resulting in minimal lactate increases and high resuscitability and survival without

  18. Effects of training on muscle O2 transport at VO2max

    NASA Technical Reports Server (NTRS)

    Roca, J.; Agusti, A. G.; Alonso, A.; Poole, D. C.; Viegas, C.; Barbera, J. A.; Rodriguez-Roisin, R.; Ferrer, A.; Wagner, P. D.

    1992-01-01

    To quantify the relative contributions of convective and peripheral diffusive components of O2 transport to the increase in leg O2 uptake (VO2leg) at maximum O2 uptake (VO2max) after 9 wk of endurance training, 12 sedentary subjects (age 21.8 +/- 3.4 yr, VO2max 36.9 +/- 5.9 ml.min-1.kg-1) were studied. VO2max, leg blood flow (Qleg), and arterial and femoral venous PO2, and thus VO2leg, were measured while the subjects breathed room air, 15% O2, and 12% O2. The sequence of the three inspirates was balanced. After training, VO2max and VO2leg increased at each inspired O2 concentration [FIO2; mean over the 3 FIO2 values 25.2 +/- 17.8 and 36.5 +/- 33% (SD), respectively]. Before training, VO2leg and mean capillary PO2 were linearly related through the origin during hypoxia but not during room air breathing, suggesting that, at 21% O2, VO2max was not limited by O2 supply. After training, VO2leg and mean capillary PO2 at each FIO2 fell along a straight line with zero intercept, just as in athletes (Roca et al. J. Appl. Physiol. 67: 291-299, 1989). Calculated muscle O2 diffusing capacity (DO2) rose 34% while Qleg increased 19%. The relatively greater rise in DO2 increased the DO2/Qleg, which led to 9.9% greater O2 extraction. By numerical analysis, the increase in Qleg alone (constant DO2) would have raised VO2leg by 35 ml/min (mean), but that of DO2 (constant Qleg) would have increased VO2leg by 85 ml/min, more than twice as much. The sum of these individual effects (120 ml/min) was less (P = 0.013) than the observed rise of 164 ml/min (mean). This synergism (explained by the increase in DO2/Qleg) seems to be an important contribution to increases in VO2max with training.

  19. Van der Waals MoS2/VO2 heterostructure junction with tunable rectifier behavior and efficient photoresponse.

    PubMed

    Oliva, Nicoló; Casu, Emanuele Andrea; Yan, Chen; Krammer, Anna; Rosca, Teodor; Magrez, Arnaud; Stolichnov, Igor; Schueler, Andreas; Martin, Olivier J F; Ionescu, Adrian Mihai

    2017-10-27

    Junctions between n-type semiconductors of different electron affinity show rectification if the junction is abrupt enough. With the advent of 2D materials, we are able to realize thin van der Waals (vdW) heterostructures based on a large diversity of materials. In parallel, strongly correlated functional oxides have emerged, having the ability to show reversible insulator-to-metal (IMT) phase transition by collapsing their electronic bandgap under a certain external stimulus. Here, we report for the first time the electronic and optoelectronic characterization of ultra-thin n-n heterojunctions fabricated using deterministic assembly of multilayer molybdenum disulphide (MoS 2 ) on a phase transition material, vanadium dioxide (VO 2 ). The vdW MoS 2 /VO 2 heterojunction combines the excellent blocking capability of an n-n junction with a high conductivity in on-state, and it can be turned into a Schottky rectifier at high applied voltage or at temperatures higher than 68 °C, exploiting the metal state of VO 2 . We report tunable diode-like current rectification with a good diode ideality factor of 1.75 and excellent conductance swing of 120 mV/dec. Finally, we demonstrate unique tunable photosensitivity and excellent junction photoresponse in the 500/650 nm wavelength range.

  20. Multiple variables explain the variability in the decrement in VO2max during acute hypobaric hypoxia.

    PubMed

    Robergs, R A; Quintana, R; Parker, D L; Frankel, C C

    1998-06-01

    We used multiple regression analyses to determine the relationships between the decrement in sea level (SL, 760 Torr) VO2max during hypobaric hypoxia (HH) and variables that could alter or be related to the decrement in VO2max. HH conditions consisted of 682 Torr, 632 Torr, and 566 Torr, and the measured independent variables were SL-VO2max, SL lactate threshold (SL-LT), the change in hemoglobin saturation at VO2max between 760 and 566 Torr (delta SaO2max), lean body mass (LBM), and gender. Male (N = 14) and female (N = 14) subjects of varied fitness, training status, and residential altitude (1,640-2,460 m) completed cycle ergometry tests of VO2max at each HH condition under randomized and single-blinded conditions. VO2max decreased significantly from 760 Torr after 682 Torr (approximately 915 m) (3.5 +/- 0.9 to 3.4 +/- 0.8 L.min-1, P = 0.0003). Across all HH conditions, the slope of the relative decrement in VO2max (%VO2max) during HH was -9.2%/100 mm Hg (-8.1%/1000 m) with an initial decrease from 100% estimated to occur below 705 Torr (610 m). Step-wise multiple regression revealed that SL-VO2max, SL-LT, delta SaO2max, LBM, and gender each significantly combined to account for 89.03% of the variance in the decrement in VO2max (760-566 Torr) (P < 0.001). Individuals who have a combination of a large SL-VO2max, a small SL-LT (VO2, L.min-1), greater reductions in delta SaO2max, a large LBM, and are male have the greatest decrement in VO2max during HH. The unique variance explanation afforded by SL-LT, LBM, and gender suggests that issues pertaining to oxygen diffusion within skeletal muscle may add to the explanation of between subjects variability in the decrement in VO2max during HH.

  1. Investigation of electron beam lithography effects on metal-insulator transition behavior of vanadium dioxide

    NASA Astrophysics Data System (ADS)

    Yuce, H.; Alaboz, H.; Demirhan, Y.; Ozdemir, M.; Ozyuzer, L.; Aygun, G.

    2017-11-01

    Vanadium dioxide (VO2) shows metal-insulator phase transition at nearly 68 °C. This metal-insulator transition (MIT) in VO2 leads to a significant change in near-infrared transmittance and an abrupt change in the resistivity of VO2. Due to these characteristics, VO2 plays an important role on optic and electronic devices, such as thermochromic windows, meta-materials with tunable frequency, uncooled bolometers and switching devices. In this work, VO2 thin films were fabricated by reactive direct current magnetron sputtering in O2/Ar atmosphere on sapphire substrates without any further post annealing processes. The effect of sputtering parameters on optical characteristics and structural properties of grown thin films was investigated by SEM, XRD, Raman and UV/VIS spectrophotometer measurements. Patterning process of VO2 thin films was realized by e-beam lithography technique to monitor the temperature dependent electrical characterization. Electrical properties of VO2 samples were characterized using microprobe station in a vacuum system. MIT with hysteresis behavior was observed for the unpatterned square samples at around 68 °C. By four orders of magnitude of resistivity change was measured for the deposited VO2 thin films at transition temperature. After e-beam lithography process, substantial results in patterned VO2 thin films were observed. In this stage, for patterned VO2 thin films as stripes, the change in resistivity of VO2 was reduced by a factor of 10. As a consequence of electrical resistivity measurements, MIT temperature was shifted from 68 °C to 50 °C. The influence of e-beam process on the properties of VO2 thin films and the mechanism of the effects are discussed. The presented results contribute to the achievement of VO2 based thermochromic windows and bolometer applications.

  2. Microwave assisted synthesis of sheet-like Cu/BiVO{sub 4} and its activities of various photocatalytic conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xi; College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar 161006; Li, Li, E-mail: qqhrll@163.com

    2015-09-15

    The Cu/BiVO{sub 4} photocatalyst with visible-light responsivity was prepared by the microwave-assisted hydrothermal method. The phase structures, chemical composition and surface physicochemical properties were well-characterized via X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), UV–vis diffuse reflectance absorption (UV–vis/DRS), scanning electron microscopy (SEM), and N{sub 2} adsorption–desorption tests. Results indicate that the crystal structure of synthetic composite materials is mainly monoclinic scheelite BiVO{sub 4}, which is not changed with the increasing doping amount of Cu. In addition, the presence of Cu not only enlarges the range of the composite materials under the visible-light response, but also increases the BET value significantly.more » Compared to pure BiVO{sub 4}, 1% Cu/BiVO{sub 4}-160 performs the highest photocatalytic activity to degrade methylene blue under the irradiation of ultraviolet, visible and simulated sunlight. In addition, the capture experiments prove that the main active species was superoxide radicals during photocatalytic reaction. Moreover, the 1% Cu/BiVO{sub 4}-160 composite shows good photocatalytic stability after three times of recycling. - Graphical abstract: A series of BiVO{sub 4} with different amounts of Cu doping were prepared by the microwave-assisted method, moreover, which performed the high photocatalytic activities to degrade methylene blue under multi-mode. - Highlights: • A series of Cu/BiVO{sub 4} with different amounts of Cu doping were prepared by microwave-assisted synthesis. • The morphologies of as-samples were different with the amount of Cu doping increased. • Compared with pure BiVO{sub 4}, as-Cu/BiVO{sub 4} showed stronger absorption in the visible light region obviously. • 1% Cu/BiVO{sub 4}-160 performed the high photocatalytic activities to degrade methylene blue under multi-mode. • OH{sup •} and h{sup +} both play important roles in the photocatalytic reaction.« less

  3. FTIR spectra of the solid solutions (Na0.88K0.12)VO3, (Na0.5K0.5)VO3, and Na(V0.66P0.34)O3

    NASA Astrophysics Data System (ADS)

    de Waal, D.; Heyns, A. M.

    1992-03-01

    It is known that three different solid solutions, (Na0.88K0.12)VO3, (Na0.5K0.5)VO3 and Na(V0.66P0.34)O3, form in the (Na,K)(V,P)O3 system. These compounds all have monoclinic crystal structures similar to the pure alkali metal metavanadates containing small cations, e.g. Li+ and Na+ (Space group C2/c). Metavanadates with large cations like K+, Rb+, C+s and NH+4 form orthorhombic crystals, space group Pbcm. All those are structurally related to the silicate pyroxenes. Na(V0.66P0.34)O3 and (Na0.88K0.12)VO3 have the same modified diopside structure as (alpha) - NaVO3 while (Na0.5K0.5)VO3 adopts the true diopside structure. The infrared spectra of the three solid solutions are reported here in comparison with those of (alpha) -NaVO3 and KVO3. The results are also correlated with those obtained in two independent high pressure Raman studies of NH4VO3 and RbVO3 as the introduction of a larger cation like K+ should increase the pressure in the structure.

  4. Unexpected metal-insulator transition in thick Ca1-xSrxVO3 film on SrTiO3 (100) single crystal

    NASA Astrophysics Data System (ADS)

    Takayanagi, Makoto; Tsuchiya, Takashi; Namiki, Wataru; Ueda, Shigenori; Minohara, Makoto; Horiba, Koji; Kumigashira, Hiroshi; Terabe, Kazuya; Higuchi, Tohru

    2018-03-01

    Epitaxial Ca1-xSrxVO3 (0 ≦ x ≦ 1) thin films were grown on (100)-oriented SrTiO3 substrates by using the pulsed laser deposition technique. In contrast to the previous report that metal-insulator transition (MIT) in Ca1-xSrxVO3 (CSVO) was achieved only for extremely thin films (several nm thick), MIT was observed at 39, 72, and 113 K for films with a thickness of 50 nm. The electronic structure was investigated by hard and soft X-ray photoemission spectroscopy (HX-PES and SX-PES). The difference between these PES results was significant due to the variation in an escape depth of photoelectrons of PES. While HX-PES showed that the V 2p3/2 spectra consisted of four peaks (V5+, V4+, V3+, and V2+/1+), SX-PES showed only three peaks (V5+, V4+, and V3+). This difference can be caused by a strain from the substrate, which leads to the chemical disorder (V5+, V4+, V3+, and V2+/1+). The thin film near the substrate is affected by the strain. The positive magnetoresistance is attributed to the effect of electron-electron interactions in the disorder system. Therefore, the emergence of MIT can be explained by the electron-electron interactions from the chemical disorder due to the strain.

  5. Fern-like rGO/BiVO4 Hybrid Nanostructures for High-Energy Symmetric Supercapacitor.

    PubMed

    Patil, Santosh S; Dubal, Deepak P; Deonikar, Virendrakumar G; Tamboli, Mohaseen S; Ambekar, Jalindar D; Gomez-Romero, Pedro; Kolekar, Sanjay S; Kale, Bharat B; Patil, Deepak R

    2016-11-23

    Herein, we demonstrate the synthesis of rGO/BiVO 4 hybrid nanostructures by facile hydrothermal method. Morphological studies reveal that rGO sheets are embedded in the special dendritic fern-like structures of BiVO 4 . The rGO/BiVO 4 hybrid architecture shows the way to a rational design of supercapacitor, since these structures enable easy access of electrolyte ions by reducing internal resistance. Considering the unique morphological features of rGO/BiVO 4 hybrid nanostructures, their supercapacitive properties were investigated. The rGO/BiVO 4 electrode exhibits a specific capacitance of 151 F/g at the current density of 0.15 mA/cm 2 . Furthermore, we have constructed rGO/BiVO 4 symmetric cell which exhibits outstanding volumetric energy density of 1.6 mW h/cm 3 (33.7 W h/kg) and ensures rapid energy delivery with power density of 391 mW/cm 3 (8.0 kW/kg). The superior properties of symmetric supercapacitor can be attributed to the special dendritic fern-like BiVO 4 morphology and intriguing physicochemical properties of rGO.

  6. Electrochemical Synthesis of Amorphous VO2 Colloids and Their Rapid Thermal Transforming to VO2 (M) Nanoparticles with Good Thermochromic Performance.

    PubMed

    Wu, Hao; Li, Ming; Zhong, Li; Luo, Yuan Yuan; Li, Guang Hai

    2016-12-05

    Amorphous VO 2 (a-VO 2 ) colloids were synthesized by electrochemical anodic oxidation of metallic vanadium. It was found that the a-VO 2 colloids have a cotton-like morphology composed of very small clusters, and that the crystallization temperature of the a-VO 2 colloids can be adjusted either by the electrolyte of the anodic oxidation or/and the dispersion agent of the colloids. VO 2 (M) nanoparticles (NPs) (and a NP film) with an average size of about 50 nm can be obtained by a rapid thermal annealing of the a-VO 2 colloids at 310 °C under air, which is beneficial for practical applications. The VO 2 (M) NP film shows an obvious metal-semiconductor transition with a resistance less than 10 Ω in the metallic state. An integral visible transmittance of 40.7 %, a solar transmittance modulation of 9.4 %, and a resistance modulation in the order of 5×10 4 were realized in the VO 2 (M) NP film. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Comparative analysis of the 1-mile run test evaluation formulae: assessment of aerobic capacity in male law enforcement officers aged 20-23 years.

    PubMed

    Kayihan, Gürhan; Özkan, Ali; Köklü, Yusuf; Eyuboğlu, Ender; Akça, Firat; Koz, Mitat; Ersöz, Gülfem

    2014-04-01

    The purpose of this study was to compare values of aerobic performance in the 1-mile run test (1-MRT) using different formulae. Aerobic capacities of 351 male volunteers working for the Turkish National Police within the age range of 20-23 years were evaluated by the 1-MRT and the 20-metre shuttle run (20-MST). VO2max values were estimated by the prediction equations developed by George et al. (1993), Cureton et al. (1995) and Kline et al. (1987) for the 1-MRT and by Leger and Lambert (1982) for the 20-MST. The difference between the results of the different formulae was significant (p = 0.000). The correlation coefficient between the estimated VO2max using Cureton's equation, George's equation, Kline's equation and the 20-MST were 0.691 (p < 0.001), 0.486 (p < 0.001) and 0.608 (p < 0.001), respectively. The highest correlation coefficient was between the VO2max estimated by the 20-MST and Cureton's equation. Similarly, the highest correlation coefficient (r = -0.779) was between the 1-mile run time and the VO2max estimated by Cureton's equation. When analysing more vigorous exercise than sub-maximal exercise, we suggest that Cureton's equation be used to predict the VO2max from 1-mile run/walk performance in large numbers of healthy individuals with high VO2max. This research compares the use of 3 different formulae to estimate VO2max from 1-mile run/walk performance in male law enforcement officers aged 20-23 years for the first time and reports the most accurate formula to use when evaluating aerobic capacities of large numbers of healthy individuals.

  8. High-quality LaVO 3 films as solar energy conversion material

    DOE PAGES

    Zhang, Hai -Tian; Brahlek, Matthew; Ji, Xiaoyu; ...

    2017-03-21

    Mott insulating oxides and their heterostructures have recently been identified as potential photovoltaic materials with favorable absorption properties and an intrinsic built-in electric field that can efficiently separate excited electron hole pairs. At the same time, they are predicted to overcome the Shockley-Queisser limit due to strong electron electron interaction present. Despite these premises a high concentration of defects commonly observed in Mott insulating films acting as recombination centers can derogate the photovoltaic conversion efficiency. With use of the self-regulated growth kinetics in hybrid molecular beam epitaxy, this obstacle can be overcome. High-quality, stoichiometric LaVO 3 films were grown withmore » defect densities of in-gap states up to 2 orders of magnitude lower compared to the films in the literature, and a factor of 3 lower than LaVO 3 bulk single crystals. Photoconductivity measurements revealed a significant photoresponsivity increase as high as tenfold of stoichiometric LaVO 3 films compared to their nonstoichiometric counterparts. Furthermore, this work marks a critical step toward the realization of high-performance Mott insulator solar cells beyond conventional semiconductors.« less

  9. High-Quality LaVO3 Films as Solar Energy Conversion Material.

    PubMed

    Zhang, Hai-Tian; Brahlek, Matthew; Ji, Xiaoyu; Lei, Shiming; Lapano, Jason; Freeland, John W; Gopalan, Venkatraman; Engel-Herbert, Roman

    2017-04-12

    Mott insulating oxides and their heterostructures have recently been identified as potential photovoltaic materials with favorable absorption properties and an intrinsic built-in electric field that can efficiently separate excited electron-hole pairs. At the same time, they are predicted to overcome the Shockley-Queisser limit due to strong electron-electron interaction present. Despite these premises a high concentration of defects commonly observed in Mott insulating films acting as recombination centers can derogate the photovoltaic conversion efficiency. With use of the self-regulated growth kinetics in hybrid molecular beam epitaxy, this obstacle can be overcome. High-quality, stoichiometric LaVO 3 films were grown with defect densities of in-gap states up to 2 orders of magnitude lower compared to the films in the literature, and a factor of 3 lower than LaVO 3 bulk single crystals. Photoconductivity measurements revealed a significant photoresponsivity increase as high as tenfold of stoichiometric LaVO 3 films compared to their nonstoichiometric counterparts. This work marks a critical step toward the realization of high-performance Mott insulator solar cells beyond conventional semiconductors.

  10. Highly efficient photocatalytic conversion of solar energy to hydrogen by WO3/BiVO4 core-shell heterojunction nanorods

    NASA Astrophysics Data System (ADS)

    Kosar, Sonya; Pihosh, Yuriy; Bekarevich, Raman; Mitsuishi, Kazutaka; Mawatari, Kazuma; Kazoe, Yutaka; Kitamori, Takehiko; Tosa, Masahiro; Tarasov, Alexey B.; Goodilin, Eugene A.; Struk, Yaroslav M.; Kondo, Michio; Turkevych, Ivan

    2018-04-01

    Photocatalytic splitting of water under solar light has proved itself to be a promising approach toward the utilization of solar energy and the generation of environmentally friendly fuel in a form of hydrogen. In this work, we demonstrate highly efficient solar-to-hydrogen conversion efficiency of 7.7% by photovoltaic-photoelectrochemical (PV-PEC) device based on hybrid MAPbI3 perovskite PV cell and WO3/BiVO4 core-shell nanorods PEC cell tandem that utilizes spectral splitting approach. Although BiVO4 is characterized by intrinsically high recombination rate of photogenerated carriers, this is not an issue for WO3/BiVO4 core-shell nanorods, where highly conductive WO3 cores are combined with extremely thin absorber BiVO4 shell layer. Since the BiVO4 layer is thinner than the characteristic carrier diffusion length, the photogenerated charge carriers are separated at the WO3/BiVO4 heterojunction before their recombination. Also, such architecture provides sufficient optical thickness even for extremely thin BiVO4 layer due to efficient light trapping in the core-shell WO3/BiVO4 nanorods with high aspect ratio. We also demonstrate that the concept of fill factor can be used to compare I-V characteristics of different photoanodes regarding their optimization for PV/PEC tandem devices.

  11. Ferromagnetism in ferroelectric BaTiO3 induced by vacancies: Sensitive dependence on charge state, origin of magnetism, and temperature range of existence

    NASA Astrophysics Data System (ADS)

    Raeliarijaona, Aldo; Fu, Huaxiang

    2017-10-01

    Using density-functional calculations we investigate the possibility and underlying mechanism of generating ferromagnetism (FM) in ferroelectric BaTiO3 by native vacancies. For the same vacancy species but different charge states (e.g., VO0 vs VO2 +), our paper reveals a marked difference in magnetic behaviors. For instance, while VO0 is ferromagnetic, VO2 + is not. This sensitive dependence, which has often been overlooked, highlights the critical importance of taking into account different charge states. Furthermore, while oxygen vacancies have been often used in experiments to explain the vacancy-induced FM, our calculation demonstrates that Ti vacancies, in particular VTi3 - and VTi2 - with low formation energies, generate even stronger ferromagnetism in BaTiO3, with a magnetic moment which is 400% larger than that of VO0. Interestingly, this strong FM of VTi can be further enhanced by hole doping. Although both cation vacancies (VTiq) and anion vacancies (VO0) induce FM, their mechanisms differ drastically. FM of anion vacancies originates from the spin-polarized electrons at Ti sites, but FM of cation vacancies stems from the spin-polarized holes at O sites. This paper also sheds light on vacancy-induced FM by discovering that the spin densities of all three considered vacancy species are highly extended in real space, distributed far away from the vacancy. Moreover, we predict that the ferromagnetism caused by VTi3 - is able to survive at high temperatures, which is promising for room-temperature spintronic or multiferroic applications.

  12. Reactions of vanadium dioxide molecules with acetylene: infrared spectra of VO2(η(2)-C2H2)(x) (x = 1, 2) and OV(OH)CCH in solid neon.

    PubMed

    Zhou, Xiaojie; Chen, Mohua; Zhou, Mingfei

    2013-07-03

    Reactions of vanadium dioxide molecules with acetylene have been studied by matrix isolation infrared spectroscopy. Reaction intermediates and products are identified on the basis of isotopic substitutions as well as density functional frequency calculations. Ground state vanadium dioxide molecule reacts with acetylene in forming the side-on-bonded VO2(η(2)-C2H2) and VO2(η(2)-C2H2)2 complexes spontaneously on annealing in solid neon. The VO2(η(2)-C2H2) complex is characterized to have a (2)B2 ground state with C2v symmetry, whereas the VO2(η(2)-C2H2)2 complex has a (2)A ground state with C2 symmetry. The VO2(η(2)-C2H2) and VO2(η(2)-C2H2)2 complexes are photosensitive. The VO2(η(2)-C2H2) complex rearranges to the OV(OH)CCH molecule upon UV-vis light excitation.

  13. F-doped VO2 nanoparticles for thermochromic energy-saving foils with modified color and enhanced solar-heat shielding ability.

    PubMed

    Dai, Lei; Chen, Shi; Liu, Jianjun; Gao, Yanfeng; Zhou, Jiadong; Chen, Zhang; Cao, Chuanxiang; Luo, Hongjie; Kanehira, Minoru

    2013-07-28

    F-doped VO2 (M1) nanoparticles were prepared via one-pot hydrothermal synthesis. The F-doping can minimise the size of the VO2 (M1) nanoparticles, induce a homogeneous size distribution and effectively decrease the phase transition temperature to 35 °C at 2.93% F in VO2. VO2 smart glass foils obtained by casting these nanoparticles exhibit excellent thermochromism in the near-infrared region, which suggests that these foils can be used for energy-efficient glass. Compared to a pure VO2 foil, the 2.93% F-doped VO2 foil exhibits an increased solar-heat shielding ability (35.1%) and a modified comfortable colour, while still retaining an excellent solar modulation ability (10.7%) and an appropriate visible transmittance (48.7%). The F-doped VO2 foils are the first to simultaneously meet the requirements of a reduced phase transition temperature, diluted colour and excellent thermochromic properties, and these properties make the further improved F-doped VO2 foils suitable for commercial applications in energy efficient glass.

  14. Optimizing the "priming" effect: influence of prior exercise intensity and recovery duration on O2 uptake kinetics and severe-intensity exercise tolerance.

    PubMed

    Bailey, Stephen J; Vanhatalo, Anni; Wilkerson, Daryl P; Dimenna, Fred J; Jones, Andrew M

    2009-12-01

    It has been suggested that a prior bout of high-intensity exercise has the potential to enhance performance during subsequent high-intensity exercise by accelerating the O(2) uptake (Vo(2)) on-response. However, the optimal combination of prior exercise intensity and subsequent recovery duration required to elicit this effect is presently unclear. Eight male participants, aged 18-24 yr, completed step cycle ergometer exercise tests to 80% of the difference between the preestablished gas exchange threshold and maximal Vo(2) (i.e., 80%Delta) after no prior exercise (control) and after six different combinations of prior exercise intensity and recovery duration: 40%Delta with 3 min (40-3-80), 9 min (40-9-80), and 20 min (40-20-80) of recovery and 70%Delta with 3 min (70-3-80), 9 min (70-9-80), and 20 min (70-20-80) of recovery. Overall Vo(2) kinetics were accelerated relative to control in all conditions except for 40-9-80 and 40-20-80 conditions as a consequence of a reduction in the Vo(2) slow component amplitude; the phase II time constant was not significantly altered with any prior exercise/recovery combination. Exercise tolerance at 80%Delta was improved by 15% and 30% above control in the 70-9-80 and 70-20-80 conditions, respectively, but was impaired by 16% in the 70-3-80 condition. Prior exercise at 40%Delta did not significantly influence exercise tolerance regardless of the recovery duration. These data demonstrate that prior high-intensity exercise ( approximately 70%Delta) can enhance the tolerance to subsequent high-intensity exercise provided that it is coupled with adequate recovery duration (>or=9 min). This combination presumably optimizes the balance between preserving the effects of prior exercise on Vo(2) kinetics and providing sufficient time for muscle homeostasis (e.g., muscle phosphocreatine and H(+) concentrations) to be restored.

  15. High-intensity interval training improves VO2peak, maximal lactate accumulation, time trial and competition performance in 9–11-year-old swimmers

    PubMed Central

    Zinner, Christoph; Heilemann, Ilka; Kjendlie, Per-Ludvik; Holmberg, Hans-Christer; Mester, Joachim

    2010-01-01

    Training volume in swimming is usually very high when compared to the relatively short competition time. High-intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. The main purpose of the present study was to examine the effects of a 5-week HIIT versus high-volume training (HVT) in 9–11-year-old swimmers on competition performance, 100 and 2,000 m time (T100 m and T2,000 m), VO2peak and rate of maximal lactate accumulation (Lacmax). In a 5-week crossover study, 26 competitive swimmers with a mean (SD) age of 11.5 ± 1.4 years performed a training period of HIIT and HVT. Competition (P < 0.01; effect size = 0.48) and T2,000 m (P = 0.04; effect size = 0.21) performance increased following HIIT. No changes were found in T100 m (P = 0.20). Lacmax increased following HIIT (P < 0.01; effect size = 0.43) and decreased after HVT (P < 0.01; effect size = 0.51). VO2peak increased following both interventions (P < 0.05; effect sizes = 0.46–0.57). The increases in competition performance, T2,000 m, Lacmax and VO2peak following HIIT were achieved in significantly less training time (~2 h/week). PMID:20683609

  16. Highly Preorganized Ligand 1,10-Phenanthroline-2,9-dicarboxylic Acid for the Selective Recovery of Uranium from Seawater in the Presence of Competing Vanadium Species

    DOE PAGES

    Lashley, Mark A.; Ivanov, Alexander S.; Bryantsev, Vyacheslav S.; ...

    2016-09-30

    Studies of the complexation of new promising ligands with uranyl (UO 2 2+) and other seawater cations can aid the development of more efficient, selective, and robust sorbents for the recovery of uranium from seawater. Here, we propose that the ligand design principles based on structural preorganization can be successfully applied to obtain a dramatic enhancement in UO 2 2+ ion binding affinity and selectivity. This concept is exemplified through the investigation of the com-plexes of UO 2 2+, VO 2+, and VO 2+ with the highly preorganized ligand PDA (1,10-phenanthroline-2,9-dicarboxylic acid) using a combination of fluores-cence and absorbance techniques,more » along with den-sity functional theory (DFT) calculations. Moreover, the measured stability constant value, log K1, of 16.5 for the UO 2 2+/PDA complex is very high compared to uranyl complexes with other dicarboxylic ligands. Moreover, PDA exhibits strong selectivity for uranyl over vanadium ions, since the determined sta-bility constant values of the PDA complexes of the vanadium ions are quite low (V(IV) log K1 = 7.4, V(V) = 7.3). Finally, the structures of the corresponding UO 2 2+, VO 2+, and VO 2+ complexes with PDA were identified by systematic DFT calculations, and helped to interpret the stronger binding affinity for uranium over the vanadium ions. Due to its high chemical stability, selectivity, and structural preor-ganization for UO 2 2+ complexation, PDA is a very promising candidate that can be potentially used in the development of novel adsorbent materials for the selective extraction of uranium from sea-water.« less

  17. Highly Preorganized Ligand 1,10-Phenanthroline-2,9-dicarboxylic Acid for the Selective Recovery of Uranium from Seawater in the Presence of Competing Vanadium Species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lashley, Mark A.; Ivanov, Alexander S.; Bryantsev, Vyacheslav S.

    Studies of the complexation of new promising ligands with uranyl (UO 2 2+) and other seawater cations can aid the development of more efficient, selective, and robust sorbents for the recovery of uranium from seawater. Here, we propose that the ligand design principles based on structural preorganization can be successfully applied to obtain a dramatic enhancement in UO 2 2+ ion binding affinity and selectivity. This concept is exemplified through the investigation of the com-plexes of UO 2 2+, VO 2+, and VO 2+ with the highly preorganized ligand PDA (1,10-phenanthroline-2,9-dicarboxylic acid) using a combination of fluores-cence and absorbance techniques,more » along with den-sity functional theory (DFT) calculations. Moreover, the measured stability constant value, log K1, of 16.5 for the UO 2 2+/PDA complex is very high compared to uranyl complexes with other dicarboxylic ligands. Moreover, PDA exhibits strong selectivity for uranyl over vanadium ions, since the determined sta-bility constant values of the PDA complexes of the vanadium ions are quite low (V(IV) log K1 = 7.4, V(V) = 7.3). Finally, the structures of the corresponding UO 2 2+, VO 2+, and VO 2+ complexes with PDA were identified by systematic DFT calculations, and helped to interpret the stronger binding affinity for uranium over the vanadium ions. Due to its high chemical stability, selectivity, and structural preor-ganization for UO 2 2+ complexation, PDA is a very promising candidate that can be potentially used in the development of novel adsorbent materials for the selective extraction of uranium from sea-water.« less

  18. Aging, Fitness, and Marathon Times in a 91 Year-old Man Who Competed in 627 Marathons.

    PubMed

    Addison, Odessa; Steinbrenner, Gregory; Goldberg, Andrew P; Katzel, Leslie I

    Aging is associated with a decline in maximal aerobic capacity (VO 2max ) that may be attenuated by chronic endurance exercise. This case study chronicles the changes in marathon times in a 91 year old man who completed 627 marathons and 117 ultramarathons over 42 years. He began running marathons at age 48. His yearly best times remained fairly constant at ~240 minutes from age 50 - 64 years and then gradually rose to about 260 minutes in his early seventies followed by a curvilinear deterioration as he approached his ninth decade. His times plateaued at ~ 600 minutes in his late eighties. Between ages 68 and 89 his VO 2max declined from 43 to 20 ml/kg/min. His marathon times were highly correlated with his VO 2max (r 2 =0.87). The decline in marathons times and VO 2max may reflect the contributions of biological aging, changes in exercise training volume and intensity, injuries, and comorbid disease.

  19. Effect of long-term training and acute physical exercise on red cell 2,3-diphosphoglycerate.

    PubMed

    Remes, K; Vuopio, P; Härkönen, M

    1979-11-01

    A statistically significant 10% increase (p less than 0.005) in mean red cell 2,3-diphosphoglycerate (2,3-DPG) concentration, concomitantly with a mean 16% increase (p less than 0.001) in the predicted maximal oxygen uptake (VO2max) was observed in 29 recruits, who were studied during 6 months of physical training in military service. The increase in 2,3-DPG was higher, the lower the initial 2,3-DPG and VO2max levels. The mean initial 2,3-DPG level was higher in the subjects with a higher initial VO2max. A strenuous but highly aerobic 21-km marching exercise elicited a mean 9% increase (p less than 0.005) in red cell 2,3-DPG concentration. A significantly greater response of 2,3-DPG to marching exercise was observed in subjects with a lower pre-test VO2max than in those with a higher pre-test VO2max. During another more competitive march 2,3-DPG remained almost unchanged and was associated with a tendency towards a negative correlation with the acccompanying lactate response (r = -0.60, p less than 0.05). Red cell 2,3-DPG response to a standardized exercise is considered to be a suitable indicator for evaluating the effect of training on an individual.

  20. Improving the Accuracy of Predicting Maximal Oxygen Consumption (VO2pk)

    NASA Technical Reports Server (NTRS)

    Downs, Meghan E.; Lee, Stuart M. C.; Ploutz-Snyder, Lori; Feiveson, Alan

    2016-01-01

    Maximal oxygen (VO2pk) is the maximum amount of oxygen that the body can use during intense exercise and is used for benchmarking endurance exercise capacity. The most accurate method to determineVO2pk requires continuous measurements of ventilation and gas exchange during an exercise test to maximal effort, which necessitates expensive equipment, a trained staff, and time to set-up the equipment. For astronauts, accurate VO2pk measures are important to assess mission critical task performance capabilities and to prescribe exercise intensities to optimize performance. Currently, astronauts perform submaximal exercise tests during flight to predict VO2pk; however, while submaximal VO2pk prediction equations provide reliable estimates of mean VO2pk for populations, they can be unacceptably inaccurate for a given individual. The error in current predictions and logistical limitations of measuring VO2pk, particularly during spaceflight, highlights the need for improved estimation methods.

  1. Ion beam modification of single crystalline BiVO4

    NASA Astrophysics Data System (ADS)

    Wendler, Elke; Bischoff, Marie; Schmidt, Emanuel; Schrempel, F.; Ellmer, Klaus; Kanis, Michael; van de Krol, Roel

    2017-10-01

    A single crystalline BiVO4 sample was investigated. Angular resolved Rutherford backscattering spectrometry (arRBS) was performed as a function of two orthogonal angles perpendicular to the surface. The crystal planes appearing in the angular charts are compared with the crystal structure of monoclinic BiVO4. By this comparison the crystal axis being almost normal to the surface was identified to be 〈0 0 1〉. These measurements support the control of orientation and quality of the grown BiVO4 crystal. Additionally it is found that during prolonged analysis the He ions produce a considerable amount of damage. As the nuclear energy loss of the He ions is negligibly low within the corresponding depth region, the damage is mainly caused by the electronic energy loss of the ions. For studying radiation resistance and damage formation, the BiVO4 single crystal was implanted with 200 keV Ar ions. The damage production in the Bi sublattice was analysed by RBS applying 1.8 MeV He ions in channelling configuration. The damage profiles determined from the channelling RBS spectra can be well represented by the electronic energy loss of the implanted Ar ions. From this it is concluded that, in agreement with the finding mentioned above, this energy mainly triggers damage formation in ion irradiated BiVO4. The energy for producing one displaced Bi atom as seen by RBS decreases with increasing damage concentration and varies between 33 and 3.4 eV.

  2. Controlling the Temperature and Speed of the Phase Transition of VO 2 Microcrystals

    DOE PAGES

    Yoon, Joonseok; Kim, Howon; Chen, Xian; ...

    2015-12-29

    Here, we investigated the control of two important parameters of vanadium dioxide (VO 2 ) microcrystals, the phase transition temperature and speed, by varying microcrystal width. By using the reflectivity change between insulating and metallic phases, phase transition temperature is measured by optical microscopy. As the width of square cylinder-shaped microcrystals decreases from ~70 to ~1 μm, the phase transition temperature (67 °C for bulk) varied as much as 26.1 °C (19.7 °C) during heating (cooling). In addition, the propagation speed of phase boundary in the microcrystal, i.e., phase transition speed, is monitored at the onset of phase transition bymore » using the high-speed resistance measurement. The phase transition speed increases from 4.6 × 10 2 to 1.7 × 10 4 μm/s as the width decreases from ~50 to ~2 μm. While the statistical description for a heterogeneous nucleation process explains the size dependence on phase transition temperature of VO 2 , the increase of effective thermal exchange process is responsible for the enhancement of phase transition speed of small VO 2 microcrystals. These findings not only enhance the understanding of VO 2 intrinsic properties but also contribute to the development of innovative electronic devices.« less

  3. Controlling the Temperature and Speed of the Phase Transition of VO 2 Microcrystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, Joonseok; Kim, Howon; Chen, Xian

    Here, we investigated the control of two important parameters of vanadium dioxide (VO 2 ) microcrystals, the phase transition temperature and speed, by varying microcrystal width. By using the reflectivity change between insulating and metallic phases, phase transition temperature is measured by optical microscopy. As the width of square cylinder-shaped microcrystals decreases from ~70 to ~1 μm, the phase transition temperature (67 °C for bulk) varied as much as 26.1 °C (19.7 °C) during heating (cooling). In addition, the propagation speed of phase boundary in the microcrystal, i.e., phase transition speed, is monitored at the onset of phase transition bymore » using the high-speed resistance measurement. The phase transition speed increases from 4.6 × 10 2 to 1.7 × 10 4 μm/s as the width decreases from ~50 to ~2 μm. While the statistical description for a heterogeneous nucleation process explains the size dependence on phase transition temperature of VO 2 , the increase of effective thermal exchange process is responsible for the enhancement of phase transition speed of small VO 2 microcrystals. These findings not only enhance the understanding of VO 2 intrinsic properties but also contribute to the development of innovative electronic devices.« less

  4. Anomalous spectral-weight transfers unraveling oxygen screening and electronic correlations in the insulator-metal transition of VO2

    NASA Astrophysics Data System (ADS)

    Yeo, L. H.; Srivastava, A.; Majidi, M. A.; Sutarto, R.; He, F.; Poh, S. M.; Diao, C.; Yu, X.; Motapothula, M.; Saha, S.; Ojha, S.; Kanjilal, D.; Trevisanutto, P. E.; Breese, M. B. H.; Venkatesan, T.; Rusydi, A.

    2015-02-01

    Vanadium dioxide (VO2) undergoes an unusual insulator-metal transition (IMT), and after decades of study, the origin of the IMT remains hotly debated. Here, by analyzing spectral-weight transfers (SWTs) of x-ray absorption spectroscopy at the V L3 ,2 and O K edges on specially designed VO2 films, we observe d||(dx2-y2) band splitting at the V L3 ,2 edges across the IMT, accompanied by anomalous SWTs as high as ˜12 eV at the O K edge, indicating strong electronic correlations. Surprisingly, a few oxygen vacancies induce dramatic SWTs at the O K edge, but the sample remains conducting. Supported by theoretical calculations, we find that in the metallic state, direct V (3 d∥) -V(3 d∥) and O(2 p ) -V(3 d∥) hybridized orbital correlations are screened by O(2 p ) -V(3 dπ) hybridized orbitals, while in the insulating state they are strongly correlated due to changes in the oxygen orbital occupancy. Our result shows the importance of screenings and electronic correlations for IMTs in VO2.

  5. Thymoquinone suppresses migration of LoVo human colon cancer cells by reducing prostaglandin E2 induced COX-2 activation.

    PubMed

    Hsu, Hsi-Hsien; Chen, Ming-Cheng; Day, Cecilia Hsuan; Lin, Yueh-Min; Li, Shin-Yi; Tu, Chuan-Chou; Padma, Viswanadha Vijaya; Shih, Hui-Nung; Kuo, Wei-Wen; Huang, Chih-Yang

    2017-02-21

    To identify potential anti-cancer constituents in natural extracts that inhibit cancer cell growth and migration. Our experiments used high dose thymoquinone (TQ) as an inhibitor to arrest LoVo (a human colon adenocarcinoma cell line) cancer cell growth, which was detected by cell proliferation assay and immunoblotting assay. Low dose TQ did not significantly reduce LoVo cancer cell growth. Cyclooxygenase 2 (COX-2) is an enzyme that is involved in the conversion of arachidonic acid into prostaglandin E2 (PGE2) in humans. PGE2 can promote COX-2 protein expression and tumor cell proliferation and was used as a control. Our results showed that 20 μmol/L TQ significantly reduced human LoVo colon cancer cell proliferation. TQ treatment reduced the levels of p-PI3K, p-Akt, p-GSK3β, and β-catenin and thereby inhibited the downstream COX-2 expression. Results also showed that the reduction in COX-2 expression resulted in a reduction in PGE2 levels and the suppression of EP2 and EP4 activation. Further analysis showed that TG treatment inhibited the nuclear translocation of β-catenin in LoVo cancer cells. The levels of the cofactors LEF-1 and TCF-4 were also decreased in the nucleus following TQ treatment in a dose-dependent manner. Treatment with low dose TQ inhibited the COX-2 expression at the transcriptional level and the regulation of COX-2 expression efficiently reduced LoVo cell migration. The results were further verified in vivo by confirming the effects of TQ and/or PGE2 using tumor xenografts in nude mice. TQ inhibits LoVo cancer cell growth and migration, and this result highlights the therapeutic advantage of using TQ in combination therapy against colorectal cancer.

  6. Characterizing cerebral and locomotor muscle oxygenation to incremental ramp exercise in healthy children: relationship with pulmonary gas exchange.

    PubMed

    Vandekerckhove, Kristof; Coomans, Ilse; Moerman, Annelies; De Wolf, Daniel; Boone, Jan

    2016-12-01

    To characterize the oxygenation responses at cerebral and locomotor muscle level to incremental exercise in children and to assess the interrelationship with the pulmonary gas exchange responses. Eighteen children (9 boys, 9 girls) (mean age 10.9 ± 1.0 years) performed incremental cycle ramp exercise to exhaustion. The concentration of cerebral and muscle oxygenated (O 2 Hb) and deoxygenated (HHb) hemoglobin (by means of near-infrared spectroscopy) and pulmonary gas exchange was recorded. Cerebral and muscle O 2 Hb and HHb values were expressed as functions of oxygen uptake (VO 2 ) and breakpoints were detected by means of double linear model analysis. The respiratory compensation point (RCP) was determined. The breakpoints in cerebral and muscle O 2 Hb and HHb were compared and correlated to RCP. The subjects reached peak power output of 105 ± 18 W and VO 2peak of 43.5 ± 7.0 ml min -1  kg -1 . Cerebral O 2 Hb increased to an intensity of 89.4 ± 5.5 %VO 2peak , where a breakpoint occurred at which cerebral O 2 Hb started to decrease. Cerebral HHb increased slightly to 88.1 ± 4.8 %VO 2peak , at which the increase was accelerated. Muscle HHb increased to 90.5 ± 4.8 %VO 2peak where a leveling-off occurred. RCP occurred at 89.3 ± 4.3 %VO 2peak . The breakpoints and RCP did not differ significantly (P = 0.13) and were strongly correlated (r > 0.70, P < 0.05). There were no differences between boys and girls (P = 0.43) and there was no significant correlation with VO 2peak (P > 0.05). It was shown that cerebral and muscle oxygenation responses undergo significant changes as work rate increases and show breakpoints in the ongoing response at high intensity (85-95 %VO 2peak ). These breakpoints are strongly interrelated and associated with changes in pulmonary gas exchange.

  7. Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.

    PubMed

    Reis, Victor M; den Tillaar, Roland Van; Marques, Mario C

    2011-01-01

    The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x < 5% at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity associated with the 4 mmol·L(-1) threshold.The results of the present study show that, in highly trained runners, it is possible to use heart rate as an accurate index of the external work rate during sub maximal running speeds.

  8. Photocatalytic generation of hydrogen by core-shell WO3/BiVO4 nanorods with ultimate water splitting efficiency

    PubMed Central

    Pihosh, Yuriy; Turkevych, Ivan; Mawatari, Kazuma; Uemura, Jin; Kazoe, Yutaka; Kosar, Sonya; Makita, Kikuo; Sugaya, Takeyoshi; Matsui, Takuya; Fujita, Daisuke; Tosa, Masahiro; Kondo, Michio; Kitamori, Takehiko

    2015-01-01

    Efficient photocatalytic water splitting requires effective generation, separation and transfer of photo-induced charge carriers that can hardly be achieved simultaneously in a single material. Here we show that the effectiveness of each process can be separately maximized in a nanostructured heterojunction with extremely thin absorber layer. We demonstrate this concept on WO3/BiVO4+CoPi core-shell nanostructured photoanode that achieves near theoretical water splitting efficiency. BiVO4 is characterized by a high recombination rate of photogenerated carriers that have much shorter diffusion length than the thickness required for sufficient light absorption. This issue can be resolved by the combination of BiVO4 with more conductive WO3 nanorods in a form of core-shell heterojunction, where the BiVO4 absorber layer is thinner than the carrier diffusion length while it’s optical thickness is reestablished by light trapping in high aspect ratio nanostructures. Our photoanode demonstrates ultimate water splitting photocurrent of 6.72 mA cm−2 under 1 sun illumination at 1.23 VRHE that corresponds to ~90% of the theoretically possible value for BiVO4. We also demonstrate a self-biased operation of the photoanode in tandem with a double-junction GaAs/InGaAsP photovoltaic cell with stable water splitting photocurrent of 6.56 mA cm−2 that corresponds to the solar to hydrogen generation efficiency of 8.1%. PMID:26053164

  9. Photocatalytic generation of hydrogen by core-shell WO3/BiVO4 nanorods with ultimate water splitting efficiency

    NASA Astrophysics Data System (ADS)

    Pihosh, Yuriy; Turkevych, Ivan; Mawatari, Kazuma; Uemura, Jin; Kazoe, Yutaka; Kosar, Sonya; Makita, Kikuo; Sugaya, Takeyoshi; Matsui, Takuya; Fujita, Daisuke; Tosa, Masahiro; Kondo, Michio; Kitamori, Takehiko

    2015-06-01

    Efficient photocatalytic water splitting requires effective generation, separation and transfer of photo-induced charge carriers that can hardly be achieved simultaneously in a single material. Here we show that the effectiveness of each process can be separately maximized in a nanostructured heterojunction with extremely thin absorber layer. We demonstrate this concept on WO3/BiVO4+CoPi core-shell nanostructured photoanode that achieves near theoretical water splitting efficiency. BiVO4 is characterized by a high recombination rate of photogenerated carriers that have much shorter diffusion length than the thickness required for sufficient light absorption. This issue can be resolved by the combination of BiVO4 with more conductive WO3 nanorods in a form of core-shell heterojunction, where the BiVO4 absorber layer is thinner than the carrier diffusion length while it’s optical thickness is reestablished by light trapping in high aspect ratio nanostructures. Our photoanode demonstrates ultimate water splitting photocurrent of 6.72 mA cm-2 under 1 sun illumination at 1.23 VRHE that corresponds to ~90% of the theoretically possible value for BiVO4. We also demonstrate a self-biased operation of the photoanode in tandem with a double-junction GaAs/InGaAsP photovoltaic cell with stable water splitting photocurrent of 6.56 mA cm-2 that corresponds to the solar to hydrogen generation efficiency of 8.1%.

  10. Photoinduced surface plasmon switching at VO2/Au interface.

    PubMed

    Kumar, Nardeep; Rúa, Armando; Aldama, Jennifer; Echeverría, Karla; Fernández, Félix E; Lysenko, Sergiy

    2018-05-28

    Angle-resolved reflection, light scattering and ultrafast pump-probe spectroscopy combined with a surface plasmon-polariton (SPP) resonance technique in attenuated total reflection geometry was used to investigate the light-induced plasmonic switching in a photorefractive VO 2 /Au hybrid structure. Measurements of SPP scattering and reflection shows that the optically-induced formation of metallic state in a vanadium dioxide layer deposited on a gold film significantly alters the electromagnetic field enhancement and SPP propagation length at the VO 2 /Au interface. The ultrafast optical manipulation of SPP resonance is shown on a picosecond timescale. Obtained results demonstrate high potential of photorefractive vanadium oxides as efficient plasmonic modulating materials for ultrafast optoelectronic devices.

  11. Spectroscopic characterisation of Er-doped LuVO4 single crystals

    NASA Astrophysics Data System (ADS)

    Lisiecki, R.; Dominiak-Dzik, G.; Solarz, P.; Strzęp, A.; Ryba-Romanowski, W.; Łukasiewicz, T.

    2010-12-01

    The LuVO4:Er single crystals were grown by the Czochralski technique. The crystal-field split energy levels of Er3+ ion were derived experimentally employing absorption and emission spectra measured at T=10 K. The Judd-Ofelt phenomenological method was used to estimate intensity parameters, radiative lifetimes and branching ratios of luminescence. The excited state dynamics of the LuVO4:Er systems was investigated and experimental lifetimes of emitting levels were measured. The emission cross section of the 4I13/2→4I15/2 transition in the infrared was calculated by the Füchtbauer-Ladenburg method. The gain cross section, estimated for several inverse-population parameters, allowed us to evaluate a potential laser activity of the LuVO4:Er system at 1.6 μm. Also, the potential range of the optical pumping was assessed based on absorption spectra achieved at the room temperature. The optical losses related to the green up-converted emission, encountered under the 978 nm excitation between 300 and 670 K were indicated and discussed. Spectroscopic peculiarities of the Er3+-doped LuVO4 crystal were discussed in relation to optical properties of the YVO4:Er and GdVO4:Er crystals. Taking into account the high quantum efficiency of the 4I13/2 level, and satisfactory absorption and emission features, the LuVO4:Er crystal can be considered as a promising active material for laser operation near 1.6 μm.

  12. [Dynamics of oxygen uptake during a 100 m front crawl event, performed during competition ].

    PubMed

    Jalab, Chadi; Enea, Carina; Delpech, Nathalie; Bernard, Olivier

    2011-04-01

    The main purpose of this study is to estimate the dynamics of oxygen uptake (VO2) during a 100 m front crawl event, performed in competition conditions. Eleven trained swimmers participated in 2 separate sessions, in a 25 m swimming pool. Maximal oxygen uptake (VO2max) was determined during a 400 m maximal event. Swimmers also performed a 100 m front crawl in competition conditions, and then, 3 tests (25, 50, and 75 m) following the pacing strategy of the 100 m event. To be free of technical constraints, VO2 was not measured during the tests, but before and just at the end of each test with a 1 min breath-by-breath method. Each post-test VO2 measurement (after 25, 50, 75, and 100 m) allows us to reconstruct the VO2 kinetics of the 100 m performance. Our results differ from previous studies in that VO2 increases faster in the first half of the race (at 50 m, VO2 ≈ 94% VO2max), reaches VO2max at the 75 m mark; then a decrease in VO2 corresponding to 7% of VO2max appears during the last 25 m. These differences are supposed to be mainly the consequences of the adoption of technical elements and a pacing strategy similar to competition conditions. In the future, these observations may lead to different considerations of the bioenergetic contributions.

  13. Study on the intrinsic defects in ZnO by combing first-principle and thermodynamic calculations

    NASA Astrophysics Data System (ADS)

    Ma, Changmin; Liu, Tingyu; Chang, Qiuxiang

    2015-11-01

    In this paper, the intrinsic point defects in ZnO crystal have been studied by the approach that integrates first-principles, thermodynamic calculations and the contributions of vibrational entropy. With temperature increasing and oxygen partial pressure decreasing, the formation energies of oxygen vacancy (VO), zinc interstitial (Zni) and zinc anti-site (ZnO) are decreasing, while it increases for zinc vacancy (VZn), oxygen interstitial (Oi) and oxygen anti-site (OZn). They are more sensitive to temperature than oxygen partial pressure. There are two interesting phenomena. First, VO or VZn have the lowest formation energies for whole Fermi level at special environment condition (such as at T = 300K, about PO2 = 10-10atm or T = 1500K, about PO2 = 104atm) and intrinsic p-type doping of ZnO is possible by VZn at these special conditions. Second, VO as donors have lowest formation energy for all Fermi level at high temperature and low oxygen partial pressure (T = 1500K, PO2 = 10-10atm). According to our analysis, the VO could produce n-type doping in ZnO at these special conditions and change p-type ZnO to n-type ZnO at condition from low temperature and high oxygen partial pressure to high temperature and low oxygen partial pressure.

  14. Weapon Carrying Among Victims of Bullying.

    PubMed

    Pham, Tammy B; Schapiro, Lana E; John, Majnu; Adesman, Andrew

    2017-12-01

    To examine, in a large, nationally representative sample of high school students, the association between bullying victimization and carrying weapons to school and to determine to what extent past experience of 1, 2, or 3 additional indicators of peer aggression increases the likelihood of weapon carrying by victims of bullying (VoBs). National data from the 2015 Youth Risk Behavior Survey were analyzed for grades 9 to 12 ( N = 15 624). VoB groups were determined by self-report of being bullied at school and additional adverse experiences: fighting at school, being threatened or injured at school, and skipping school out of fear for one's safety. Weapon carrying was measured by a dichotomized (ie, ≥1 vs 0) report of carrying a gun, knife, or club on school property. VoB groups were compared with nonvictims with respect to weapon carrying by logistic regression adjusting for sex, grade, and race/ethnicity. When surveyed, 20.2% of students reported being a VoB in the past year, and 4.1% reported carrying a weapon to school in the past month. VoBs experiencing 1, 2, or 3 additional risk factors were successively more likely to carry weapons to school. The subset of VoBs who experienced all 3 additional adverse experiences were more likely to carry weapons to school compared with nonvictims (46.4% vs 2.5%, P < .001). Pediatricians should recognize that VoBs, especially those who have experienced 1 or more indicators of peer aggression in conjunction, are at substantially increased risk of weapon carrying. Copyright © 2017 by the American Academy of Pediatrics.

  15. Physiological Demands of Simulated Off-Road Cycling Competition

    PubMed Central

    Smekal, Gerhard; von Duvillard, Serge P.; Hörmandinger, Maximilian; Moll, Roland; Heller, Mario; Pokan, Rochus; Bacharach, David W.; LeMura, Linda M.; Arciero, Paul

    2015-01-01

    The purpose of the study was to measure the demands of off-road cycling via portable spirometry, leg-power output (PO), heart rate (HR) and blood lactate (BLa) concentration. Twenty-four male competitive cyclists (age: 29±7.2 yrs, height: 1.79 ± 0.05 m, body mass: 70.0 ± 4.9 kg, VO2peak: 64.9 ± 7.5 ml·kg-1·min-1) performed simulated mountain bike competitions (COMP) and laboratory tests (LabT). From LabT, we determined maximal workload and first and second ventilatory thresholds (VT1, VT2). A high-performance athlete (HPA) was used for comparison with three groups of subjects with different sport-specific performance levels. Load profiles of COMP were also investigated during uphill, flat and downhill cycling. During the COMP, athletes achieved a mean oxygen uptake (VO2COMP) of 57.0 ± 6.8 ml·kg-1·min-1 vs. 71.1 ml·kg-1·min-1 for the HPA. The POCOMP was 2.66±0.43 W·kg-1 and 3.52 W·kg-1 for the HPA. POCOMP, VO2COMP and HRCOMP were compared to corresponding variables at the VT2 of LabT. LabT variables correlated with racing time (RTCOMP) and POCOMP (p < 0.01 to <0.001; r-0.59 to -0.80). The VO2peak (LabT) accounted for 65% of variance of a single COMP test. VO2COMP, POCOMP and also endurance variables measured from LabTs were found as important determinants for cross-country performance. The high average VO2COMP indicates that a high aerobic capacity is a prerequisite for successful COMP. Findings derived from respiratory gas measures during COMPs might be useful when designing mountain bike specific training. Key points Cross- country cycling is characterized by high oxygen costs due to the high muscle mass simultaneously working to fulfill the demands of this kind of sports. Heart rate and blood lactate concentration measures are not sensitive enough to assess the energy requirements of COMP. Therefore, respiratory gas and power output measures are helpful to provide new information to physiological profile of cross- country cycling. An excellent cycling-specific capacity is a prerequisite for successful off-road cycling. Data determined from LabT might be utilized to describe semi-specific abilities of MB- athletes on a cycle ergometer, while data originating from COMP might be useful when designing a mountain bike specific training. PMID:26664277

  16. Hydrothermal route to VO2 (B) nanorods: controlled synthesis and characterization

    NASA Astrophysics Data System (ADS)

    Song, Shaokun; Huang, Qiwei; Zhu, Wanting

    2017-10-01

    One-dimensional vanadium dioxides have attracted intensive attention owing to their distinctive structure and novel applications in catalysis, high energy lithium-ion batteries, chemical sensors/actuators and electrochemical devices etc. In this paper, large-scale VO2 (B) nanorods have been successfully synthesized via a versatile and environment friendly hydrothermal strategy using V2O5 as vanadium source and carbohydrates/alcohols as reductant. The obtained samples are characterized by XRD, FT-IR, TEM, and XPS techniques to investigate the effects of chemical parameters such as reductants, temperature, and time of synthesis on the structure and morphology of products. Results show that pure B phase VO2 with homogeneous nanorod-like morphology can be prepared easily at 180 °C for 3 days with glycerol as reluctant. Typically, the nanorod-like products are 0.5-1 μm long and 50 nm width. Furthermore, it is also confirmed that the products are consisted of VO2, corresponding to the B phase. More importantly, this novel approach is efficient, free of any harmful solvents and surfactants. Therefore, this efficient, green, and cost-saving route will have great potential in the large-scale fabrication of 1D VO2 (B) nanorods from the economic and environmental point of view.

  17. Metal-insulator transition characteristics of VO2 thin films grown on Ge(100) single crystals

    NASA Astrophysics Data System (ADS)

    Yang, Z.; Ko, C.; Ramanathan, S.

    2010-10-01

    Phase transitions exhibited by correlated oxides could be of potential relevance to the emerging field of oxide electronics. We report on the synthesis of high-quality VO2 thin films grown on single crystal Ge(100) substrates by physical vapor deposition and their metal-insulator transition (MIT) properties. Thermally triggered MIT is demonstrated with nearly three orders of magnitude resistance change across the MIT with transition temperatures of 67 °C (heating) and 61 °C (cooling). Voltage-triggered hysteretic MIT is observed at room temperature at threshold voltage of ˜2.1 V for ˜100 nm thickness VO2 films. Activation energies for electron transport in the insulating and conducting states are obtained from variable temperature resistance measurements. We further compare the properties of VO2 thin films grown under identical conditions on Si(100) single crystals. The VO2 thin films grown on Ge substrate show higher degree of crystallinity, slightly reduced compressive strain, larger resistance change across MIT compared to those grown on Si. Depth-dependent x-ray photoelectron spectroscopy measurements were performed to provide information on compositional variation trends in the two cases. These results suggest Ge could be a suitable substrate for further explorations of switching phenomena and devices for thin film functional oxides.

  18. Block training periodization in alpine skiing: effects of 11-day HIT on VO2max and performance.

    PubMed

    Breil, Fabio A; Weber, Simone N; Koller, Stefan; Hoppeler, Hans; Vogt, Michael

    2010-08-01

    Attempting to achieve the high diversity of training goals in modern competitive alpine skiing simultaneously can be difficult and may lead to compromised overall adaptation. Therefore, we investigated the effect of block training periodization on maximal oxygen consumption (VO2max) and parameters of exercise performance in elite junior alpine skiers. Six female and 15 male athletes were assigned to high-intensity interval (IT, N = 13) or control training groups (CT, N = 8). IT performed 15 high-intensity aerobic interval (HIT) sessions in 11 days. Sessions were 4 x 4 min at 90-95% of maximal heart rate separated by 3-min recovery periods. CT continued their conventionally mixed training, containing endurance and strength sessions. Before and 7 days after training, subjects performed a ramp incremental test followed by a high-intensity time-to-exhaustion (tlim) test both on a cycle ergometer, a 90-s high-box jump test as well as countermovement (CMJ) and squat jumps (SJ) on a force plate. IT significantly improved relative VO2max by 6.0% (P < 0.01; male +7.5%, female +2.1%), relative peak power output by 5.5% (P < 0.01) and power output at ventilatory threshold 2 by 9.6% (P < 0.01). No changes occurred for these measures in CT. tlim remained unchanged in both groups. High-box jump performance was significantly improved in males of IT only (4.9%, P < 0.05). Jump peak power (CMJ -4.8%, SJ -4.1%; P < 0.01), but not height decreased in IT only. For competitive alpine skiers, block periodization of HIT offers a promising way to efficiently improve VO2max and performance. Compromised explosive jump performance might be associated with persisting muscle fatigue.

  19. A comparison of practical assessment methods to determine treadmill, cycle and elliptical ergometer VO2peak

    PubMed Central

    Mays, Ryan J.; Boér, Nicholas F.; Mealey, Lisa M.; Kim, Kevin H.; Goss, Fredric L.

    2015-01-01

    This investigation compared estimated and predicted peak oxygen consumption (VO2peak) and maximal heart rate (HRmax) among the treadmill, cycle ergometer and elliptical ergometer. Seventeen women (mean ± SE: 21.9 ± .3 yrs) exercised to exhaustion on all modalities. ACSM metabolic equations were used to estimate VO2peak. Digital displays on the elliptical ergometer were used to estimate VO2peak. Two individual linear regression methods were used to predict VO2peak: 1) two steady state heart rate (HR) responses up to 85% of age-predicted HRmax, and 2) multiple steady state/non-steady state HR responses up to 85% of age-predicted HRmax. Estimated VO2peak for the treadmill (46.3 ± 1.3 ml · kg−1 · min−1) and the elliptical ergometer (44.4 ± 1.0 ml · kg−1 · min−1) did not differ. The cycle ergometer estimated VO2peak (36.5 ± 1.0 ml · kg−1 · min−1) was lower (p < .001) than the estimated VO2peak values for the treadmill and elliptical ergometer. Elliptical ergometer VO2peak predicted from steady state (51.4 ± .8 ml · kg−1 · min−1) and steady state/non-steady state (50.3 ± 2.0 ml · kg−1 · min−1) models were higher than estimated elliptical ergometer VO2peak, p < .01. HRmax and estimates of VO2peak were similar between the treadmill and elliptical ergometer, thus cross-modal exercise prescriptions may be generated. The use of digital display estimates of submaximal oxygen uptake for the elliptical ergometer may not be an accurate method for predicting VO2peak. Health-fitness professionals should use caution when utilizing submaximal elliptical ergometer digital display estimates to predict VO2peak. PMID:20393357

  20. Evolution of Structural and Electrical Properties of Oxygen-Deficient VO2 under Low Temperature Heating Process.

    PubMed

    Zhang, Jiasong; Zhao, Zhengjing; Li, Jingbo; Jin, Haibo; Rehman, Fida; Chen, Pengwan; Jiang, Yijie; Chen, Chunxu; Cao, Maosheng; Zhao, Yongjie

    2017-08-16

    Structural stability and functional performances of vanadium dioxide (VO 2 ) are strongly influenced by oxygen vacancies. However, the mechanism of metal-insulator transition (MIT) influenced by defects is still under debate. Here, we study the evolution of structure and electrical property of oxygen-deficient VO 2 by a low temperature annealing process (LTP) based on a truss-structured VO 2 nanonet. The oxygenation process of the oxygen-deficient VO 2 is greatly prolonged, which enables us to probe the gradual change of properties of the oxygen-deficient VO 2 . A continuous lattice reduction is observed during LTP. No recrystallization and structural collapse of the VO 2 nanonet can be found after LTP. The valence-band X-ray photoelectron spectroscopy (XPS) measurements indicate that the oxygen deficiency strongly affects the energy level of the valence band edge. Correspondingly, the resistance changes of the VO 2 films from 1 to 4.5 orders of magnitude are achieved by LTP. The effect of oxygen vacancy on the electric field driven MIT is investigated. The threshold value of voltage triggering the MIT decreases with increasing the oxygen vacancy concentration. This work demonstrates a novel and effective way to control the content of oxygen vacancies in VO 2 and the obvious impact of oxygen vacancy on MIT, facilitating further research on the role of oxygen vacancy in structure and MIT of VO 2 , which is important for the deep understanding of MIT and exploiting innovative functional application of VO 2 .

  1. Electronic transport in VO 2 —Experimentally calibrated Boltzmann transport modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinaci, Alper; Kado, Motohisa; Rosenmann, Daniel

    2015-12-28

    Materials that undergo metal-insulator transitions (MITs) are under intense study because the transition is scientifically fascinating and technologically promising for various applications. Among these materials, VO2 has served as a prototype due to its favorable transition temperature. While the physical underpinnings of the transition have been heavily investigated experimentally and computationally, quantitative modeling of electronic transport in the two phases has yet to be undertaken. In this work, we establish a density-functional-theory (DFT)-based approach to model electronic transport properties in VO2 in the semiconducting and metallic regimes, focusing on band transport using the Boltzmann transport equations. We synthesized high qualitymore » VO2 films and measured the transport quantities across the transition, in order to calibrate the free parameters in the model. We find that the experimental calibration of the Hubbard correction term can efficiently and adequately model the metallic and semiconducting phases, allowing for further computational design of MIT materials for desirable transport properties.« less

  2. Stoichiometric and Oxygen-Deficient VO2 as Versatile Hole Injection Electrode for Organic Semiconductors.

    PubMed

    Fu, Keke; Wang, Rongbin; Katase, Takayoshi; Ohta, Hiromichi; Koch, Norbert; Duhm, Steffen

    2018-03-28

    Using photoemission spectroscopy, we show that the surface electronic structure of VO 2 is determined by the temperature-dependent metal-insulator phase transition and the density of oxygen vacancies, which depends on the temperature and ultrahigh vacuum (UHV) conditions. The atomically clean and stoichiometric VO 2 surface is insulating at room temperature and features an ultrahigh work function of up to 6.7 eV. Heating in UHV just above the phase transition temperature induces the expected metallic phase, which goes in hand with the formation of oxygen defects (up to 6% in this study), but a high work function >6 eV is maintained. To demonstrate the suitability of VO 2 as hole injection contact for organic semiconductors, we investigated the energy-level alignment with the prototypical organic hole transport material N, N'-di(1-naphthyl)- N, N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine (NPB). Evidence for strong Fermi-level pinning and the associated energy-level bending in NPB is found, rendering an Ohmic contact for holes.

  3. Multi-electron oxygen reduction by a hybrid visible-light-photocatalyst consisting of metal-oxide semiconductor and self-assembled biomimetic complex.

    PubMed

    Naya, Shin-ichi; Niwa, Tadahiro; Negishi, Ryo; Kobayashi, Hisayoshi; Tada, Hiroaki

    2014-12-08

    Adsorption experiments and density functional theory (DFT) simulations indicated that Cu(acac)2 is chemisorbed on the monoclinic sheelite (ms)-BiVO4 surface to form an O2-bridged binuclear complex (OBBC/BiVO4) like hemocyanin. Multi-electron reduction of O2 is induced by the visible-light irradiation of the OBBC/BiVO4 in the same manner as a blue Cu enzyme. The drastic enhancement of the O2 reduction renders ms-BiVO4 to work as a good visible-light photocatalyst without any sacrificial reagents. As a model reaction, we show that this biomimetic hybrid photocatalyst exhibits a high level of activity for the aerobic oxidation of amines to aldehydes in aqueous solution and imines in THF solution at 25 °C giving selectivities above 99% under visible-light irradiation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Microwave-Assisted Synthesis of Silver Vanadium Phosphorus Oxide, Ag 2VO 2PO 4 : Crystallite Size Control and Impact on Electrochemistry

    DOE PAGES

    Huang, Jianping; Marschilok, Amy C.; Takeuchi, Esther S.; ...

    2016-03-07

    We study silver vanadium phosphorus oxide, Ag 2VO 2PO 4, that is a promising cathode material for Li batteries due in part to its large capacity and high current capability. Herein, a new synthesis of Ag 2VO 2PO 4 based on microwave heating is presented, where the reaction time is reduced by approximately 100× relative to other reported methods, and the crystallite size is controlled via synthesis temperature, showing a linear correlation of crystallite size with temperature. Notably, under galvanostatic reduction, the Ag 2VO 2PO 4 sample with the smallest crystallite size delivers the highest capacity and shows the highestmore » loaded voltage. Further, pulse discharge tests show a significant resistance decrease during the initial discharge coincident with the formation of Ag metal. Thus, the magnitude of the resistance decrease observed during pulse tests depends on the Ag 2VO 2PO 4 crystallite size, with the largest resistance decrease observed for the smallest crystallite size. Additional electrochemical measurements indicate a quasi-reversible redox reaction involving Li + insertion/deinsertion, with capacity fade due to structural changes associated with the discharge/charge process. In summary, this work demonstrates a faster synthetic approach for bimetallic polyanionic materials which also provides the opportunity for tuning of electrochemical properties through control of material physical properties such as crystallite size.« less

  5. Nanoscale self-templating for oxide epitaxy with large symmetry mismatch

    DOE PAGES

    Gao, Xiang; Lee, Shinbuhm; Nichols, John A.; ...

    2016-12-02

    Direct observations using scanning transmission electron microscopy unveil an intriguing interfacial bi-layer that enables epitaxial growth of a strain-free, monoclinic, bronze-phase VO 2(B) thin film on a perovskite SrTiO 3 (STO) substrate. For this study, we observe an ultrathin (2–3 unit cells) interlayer best described as highly strained VO 2(B) nanodomains combined with an extra (Ti,V)O 2 layer on the TiO 2 terminated STO (001) surface. By forming a fully coherent interface with the STO substrate and a semi-coherent interface with the strain-free epitaxial VO 2(B) film above, the interfacial bi-layer enables the epitaxial connection of the two materials despitemore » their large symmetry and lattice mismatch.« less

  6. High-Impact Aerobic and Zumba Fitness on Increasing VO2MAX, Heart Rate Recovery and Skinfold Thickness

    NASA Astrophysics Data System (ADS)

    Suminar, T. J.; Kusnanik, N. W.; Wiriawan, O.

    2018-01-01

    Purpose of this study is to determine the significant effect of high-impact aerobics exercise, and Zumba fitness on increasing VO2Max, decreasing of heart rate recovery, and decreasing of skinfold thickness. A sample of this study is 30 members aerobics of student activity unit. Type of this study was quantitative by using a quasi-experimental design method. The design of this study used Matching-Only Design. Data were Analyzed by using the t test (paired t-test). The samples divided into three groups consisted of experimental group I, experimental group II, and control group. They were given a treatment for 8 weeks or 24 meeting. For the data, retrieval is done by MFT test, heart rate recovery test, and skinfold thickness test. Furthermore, the result was analyzed by using SPSS 21 series. In conclusion, significant effect of high-impact aerobics and Zumba fitness on increasing VO2Max, heart rate recovery, skinfold thickness.

  7. Correlation between surface morphology and electrical properties of VO2 films grown by direct thermal oxidation method

    NASA Astrophysics Data System (ADS)

    Yoon, Joonseok; Park, Changwoo; Park, Sungkyun; Mun, Bongjin Simon; Ju, Honglyoul

    2015-10-01

    We investigate surface morphology and electrical properties of VO2 films fabricated by direct thermal oxidation method. The VO2 film prepared with oxidation temperature at 580 °C exhibits excellent qualities of VO2 characteristics, e.g. a metal-insulator transition (MIT) near 67 °C, a resistivity ratio of ∼2.3 × 104, and a bandgap of 0.7 eV. The analysis of surface morphology with electrical resistivity of VO2 films reveals that the transport properties of VO2 films are closely related to the grain size and surface roughness that vary with oxidation annealing temperatures.

  8. Pain threshold is achieved at intensity above anaerobic threshold in patients with intermittent claudication.

    PubMed

    Ritti-Dias, Raphael Mendes; de Moraes Forjaz, Cláudia Lúcia; Cucato, Gabriel Grizzo; Costa, Luis Augusto Riani; Wolosker, Nelson; de Fátima Nunes Marucci, Maria

    2009-01-01

    Walking training is considered as the first treatment option for patients with peripheral arterial disease and intermittent claudication (IC). Walking exercise has been prescribed for these patients by relative intensity of peak oxygen uptake (VO2peak), ranging from 40% to 70% VO2peak, or pain threshold (PT). However, the relationship between these methods and anaerobic threshold (AT), which is considered one of the best metabolic markers for establishing training intensity, has not been analyzed. Thus, the aim of this study was to compare, in IC patients, the physiological responses at exercise intensities usually prescribed for training (% VO2peak or % PT) with the ones observed at AT. Thirty-three IC patients performed maximal graded cardiopulmonary treadmill test to assess exercise tolerance. During the test, heart rate (HR), VO2, and systolic blood pressure were measured and responses were analyzed at the following: 40% of VO2peak; 70% of VO2peak; AT; and PT. Heart rate and VO2 at 40% and 70% of VO2peak were lower than those at AT (HR: -13 +/- 9% and -3 +/- 8%, P < .01, respectively; VO2: -52 +/- 12% and -13 +/- 15%, P < .01, respectively). Conversely, HR and VO2 at PT were slightly higher than those at AT (HR: +3 +/- 8%, P < .01; VO2: +6 +/- 15%, P = .04). None of the patients achieved the respiratory compensation point. Prescribing exercise for IC patients between 40% and 70% of VO2peak will induce a lower stimulus than that at AT, whereas prescribing exercise at PT will result in a stimulus above AT. Thus, prescribing exercise training for IC patients on the basis of PT will probably produce a greater metabolic stimulus, promoting better cardiovascular benefits.

  9. Oxygen Costs of the Incremental Shuttle Walk Test in Cardiac Rehabilitation Participants: An Historical and Contemporary Analysis.

    PubMed

    Buckley, John P; Cardoso, Fernando M F; Birkett, Stefan T; Sandercock, Gavin R H

    2016-12-01

    The incremental shuttle walk test (ISWT) is a standardised assessment for cardiac rehabilitation. Three studies have reported oxygen costs (VO 2 )/metabolic equivalents (METs) of the ISWT. In spite of classic representations from these studies graphically showing curvilinear VO 2 responses to incremented walking speeds, linear regression techniques (also used by the American College of Sports Medicine [ACSM]) have been used to estimate VO 2 . The two main aims of this study were to (i) resolve currently reported discrepancies in the ISWT VO 2 -walking speed relationship, and (ii) derive an appropriate VO 2 versus walking speed regression equation. VO 2 was measured continuously during an ISWT in 32 coronary heart disease [cardiac] rehabilitation (CHD-CR) participants and 30 age-matched controls. Both CHD-CR and control group VO 2 responses were curvilinear in nature. For CHD-CR VO 2  = 4.4e 0.23 × walkingspeed (km/h) . The integrated area under the curve (iAUC) VO 2 across nine ISWT stages was greater in the CHD-CR group versus the control group (p < 0.001): CHD-CR = 423 (±86) ml·kg -1 ·min -1 ·km·h -1 ; control = 316 (±52) ml·kg -1 ·min -1 ·km·h -1 . CHD-CR group vs. control VO 2 was up to 30 % greater at higher ISWT stages. The curvilinear nature of VO 2 responses during the ISWT concur with classic studies reported over 100 years. VO 2 estimates for walking using linear regression models (including the ACSM) clearly underestimate values in healthy and CHD-CR participants, and this study provides a resolution to this when the ISWT is used for CHD-CR populations.

  10. Characterising the slope of the distance-time relationship in swimming.

    PubMed

    Dekerle, J; Brickley, G; Alberty, M; Pelayo, P

    2010-05-01

    The aim of the present study was to assess whether the critical speed calculated by the slope of the distance-time relationship (S(d-t)) represents the boundary between the heavy and severe intensity domains in swimming and would be sustainable during intermittent exercise. Nine competitive male swimmers (mean+/-SD: aged 21.2+/-2.6 yrs; peak (.)VO2 of 3866+/-529 mL min(-1)) performed, (a) four fixed-distance (100-200-400-800 m) all-out efforts to determine S(d-t) and peak (.)VO2; (b) three constant-speed efforts to exhaustion (TTE) at and 5% above and below S(d-t) (S(d-t)(+5%) and S(d-t)(-5%), respectively); (c) a set of 10 x 400 m at S(d-t) with 40-s recovery in between. Capillary blood lactate concentration ([La](B)), oxygen uptake ((.)VO2), and RPE remained stable at S(d-t)(-5%) (TTE=48.9+/-14.1 min) with end values of 3.8+/-1.9 mmol L(-1), 87+/-14% peak (.)VO2, and 4.7+/-1.3. TTE decreased at S(d-t)(+5%) (8.6+/-3.1 min), with end [La](B) of 10.2+/-1.9 mmol L(-1). Peak (.)VO2 was reached at exhaustion. Similarly, S(d-t) could only be maintained for 24.3+/-7.7 min with an increase in RPE and [La](B), (.)VO2 reaching its peak (95+/-5% peak VO2). RPE increased but [La](B) remained stable throughout the ten 400 m blocks performed at S(d-t) (overall time of 53.9+/-2.7 min). The physiological responses when swimming 5% below and 5% above S(d-t) are those characterising the heavy and severe intensity domain, respectively. While S(d-t) lies within the severe intensity domain, intermittent swims at this intensity induce [La](B) steady state alongside high rates of perceived exertion. 2009 Sports Medicine Australia. All rights reserved.

  11. Impact of isovalent doping on radiation defects in silicon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Sgourou, E. N.; Timerkaeva, D.; Chroneos, A.; Pochet, P.; Emtsev, V. V.

    2013-09-01

    Isovalent doping is an important process for the control of point defects in Si. Here, by means of infrared spectroscopy, we investigated the properties of the two main radiation-induced defects in Czochralski-Si (Cz-Si) the oxygen-vacancy (VO) and the carbon-oxygen (CiOi) centres. In particular, we investigated the effect of isovalent doping on the production, the thermal evolution, and the thermal stability of the VO and the CiOi defects. Additionally, we studied the reactions that participate upon annealing and the defects formed as a result of these reactions. Upon annealing VO is converted to VO2 defect although part of the CiOi is converted to CsO2i complexes. Thus, we studied the conversion ratios [VO2]/[VO] and [CsO2i]/[CiOi] with respect to the isovalent dopant. Additionally, the role of carbon in the above processes was discussed. A delay between the temperature characterizing the onset of the VO decay and the temperature characterizing the VO2 growth as well the further growth of VO2 after the complete disappearance of VO indicate that the VO to VO2 conversion is a complex phenomenon with many reaction processes involved. Differences exhibited between the effects of the various dopants on the properties of the two defects were highlighted. The results are discussed in view of density functional theory calculations involving the interaction of isovalent dopants with intrinsic defects, the oxygen and carbon impurities in Si.

  12. Size and composition-controlled fabrication of thermochromic metal oxide nanocrystals

    NASA Astrophysics Data System (ADS)

    Clavero, César; Slack, Jonathan L.; Anders, André

    2013-09-01

    Finding new methods for the fabrication of metal oxide nanocrystals with high control on their composition, size and crystallinity is paramount for making large-area and low-cost optical coatings. Here, we demonstrate the fabrication of thermochromic VO2 nanocrystals using a physical vapour deposition-based route, with high control over their composition, size and crystallinity. This technique presents great potential to be scaled up and integrated with in-line coaters, commonly used for large-area deposition. Optimum crystallization of the VO2 nanoparticles is achieved after post-growth annealing at 350 °C, a temperature drastically lower than that required by chemical or implantation fabrication methods. The obtained nanoparticle thin films exhibit superior modulation of the transmittance in the visible and near IR portion of the spectrum as compared to conventional VO2 thin films due to plasmonic effects, opening up a new horizon in applications such as smarts windows.

  13. Semiconductor-insulator transition in VO{sub 2} (B) thin films grown by pulsed laser deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rúa, Armando; Díaz, Ramón D.; Lysenko, Sergiy

    2015-09-28

    Thin films of B-phase VO{sub 2} were grown by pulsed-laser deposition on glass and (100)-cut MgO substrates in a temperature range from 375 to 425 °C and at higher gas pressures than usual for this technique. The films were strongly oriented, with ab-planes parallel to the substrate surface. Detailed study of surface morphology through Atomic Force Microscopy images suggest significant differences in evolution as a function of growth temperature for films on the two types of substrates. Measurements of electrical conductivities through cooling-heating cycles from room temperature to 120 K showed changes of five orders of magnitude, with steeper changes between roommore » temperature and ∼150 K, which corresponds with the extended and reversible phase transition known to occur for this material. At lower temperatures conductivities exhibited Arrhenius behavior, indicating that no further structural change was occurring and that conduction is thermally activated. In this lower temperature range, conductivity of the samples can be described by the near-neighbor hopping model. No hysteresis was found between the cooling and heating braches of the cycles, which is at variance with previous results published for VO{sub 2} (B). This apparent lack of hysteresis for thin films grown in the manner described and the large conductivity variation as a function of temperature observed for the samples suggests this material could be of interest for infrared sensing applications.« less

  14. Colloidal GdVO4:Eu3+@SiO2 nanocrystals for highly selective and sensitive detection of Cu2+ ions

    NASA Astrophysics Data System (ADS)

    Liang, Yanjie; Noh, Hyeon Mi; Park, Sung Heum; Choi, Byung Chun; Jeong, Jung Hyun

    2018-03-01

    Nowadays, in view of health and safety demands, the controlled design of selective and sensitive sensors for Cu2+ detection is of considerable importance. Therefore, we construct herein core-shell colloidal GdVO4:Eu3+@SiO2 nanocrystals (NCs) as optical sensor for the detection of Cu2+, which were synthesized by a facile hydrothermal reaction and encapsulated with a uniform layer of ultrathin silica through a sol-gel strategy. The NCs present strong red emission due to energy transfer from VO43- groups to Eu3+ when exciting with ultraviolet (UV) light. This intense red emission from Eu3+ could be selectively quenched in the presence of Cu2+ in comparison to other metal ions and the limit of detection is as low as 80 nM in aqueous solution. It is revealed that the spectral overlap between the emission band of NCs and the absorption of Cu2+ accounts for this intriguing luminescence behavior. The detection ability is highly reversible by the addition of ethylenediaminetetraacetic acid (EDTA) with the recovery of almost 100% of the original luminescence. The luminescence quenching and recovery processes can be performed repeatedly with good sensing ability. These remarkable performances allow the colloidal GdVO4:Eu3+@SiO2 NCs a promising fluorescence chemosensor for detecting Cu2+ ions in aqueous solution.

  15. Compare the phase transition properties of VO2 films from infrared to terahertz range

    NASA Astrophysics Data System (ADS)

    Liang, Shan; Shi, Qiwu; Huang, Wanxia; Peng, Bo; Mao, Zhenya; Zhu, Hongfu

    2018-06-01

    VO2 with reversible semiconductor-metal phase transition properties is particularly available for the application in smart opto-electrical devices. However, there are rare reports on comparing its phase transition properties at different ranges. In this study, the VO2 films are designed with the similar crystalline structure and stoichiometry, but different morphologies by inorganic and organic sol-gel methods, and their phase transition characteristics are compared both at infrared and terahertz range. The results indicate that the VO2 film prepared by inorganic sol-gel method shows more compact nanostructure. It results in larger resistivity change, infrared and terahertz switching ratio in the VO2 film. Moreover, it presents that the phase transition intensity of VO2 film in terahertz range is more sensitive to its microstructure. This work is helpful for understanding the susceptibility of terahertz switching properties of VO2 to its microstructure. And it can provide insights for the applications of VO2 in terahertz smart devices.

  16. Metastable α-AgVO3 microrods as peroxidase mimetics for colorimetric determination of H2O2.

    PubMed

    Wang, Yi; Zhang, Dun; Wang, Jin

    2017-12-01

    Single phase metastable α-AgVO 3 microrods with high crystallinity, tetragonal rod-like microstructure, uniform particle size distribution, and good dispersion were synthesized by direct coprecipitation at room temperature. They are shown to be viable peroxidase mimics that catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine in the presence of H 2 O 2 . Kinetic analysis indicated typical Michaelis-Menten catalytic behavior. The findings were used to design a colorimetric assay for H 2 O 2 , best measured at 652 nm. The method has a linear response in the 60 to 200 μM H 2 O 2 concentration range, with a 2 μM detection limit. Benefitting from the chemical stability of the microrods, the method is well reproducible. It also is easily performed and highly specific. Graphic abstract Single phase metastable α-AgVO 3 microrods with high crystallinity, tetragonal rod-like microstructure, uniform particle size distribution, and good dispersion can efficiently catalyze the oxidation reaction of peroxidase substrate 3,3',5,5'-tetramethylbenzidine (TMB) in the presence of H 2 O 2 to produce a blue color change.

  17. Preparation and characterization of self-supporting thermochromic films composed of VO2(M)@SiO2 Nanofibers.

    PubMed

    Li, Shaotang; Li, Yamei; Jiang, Meng; Ji, Shidong; Luo, Hongjie; Gao, Yanfeng; Jin, Ping

    2013-07-24

    Nanofibers of VO2(A) with the diameter and length averagely at 100 nm and 10-20 μm were prepared via a facile one-step hydrothermal method by reducing NH4VO3 with 1,3-propylene glycol in an acidic solution. The obtained VO2(A) was coated by SiO2 to form VO2(A)@SiO2 core-shell nanocomposites, which were then transformed into VO2(M)@SiO2 by annealing under nitrogen atmosphere. The resulted composites maintained the original fibrous morphology, particularly with a large amount of pores emerging inside the fiber due to the volume shrinkage during the phase transition, which may improve its thermal insulation ability in real applications. The VO2(M)@SiO2 nanofibers were arranged into a self-supporting film by filtration, which shows excellent thermochromic properties.

  18. Decreased maximal aerobic capacity with use of a triphasic oral contraceptive in highly active women: a randomised controlled trial

    PubMed Central

    Lebrun, C; Petit, M; McKenzie, D; Taunton, J; Prior, J

    2003-01-01

    Background: Oral contraceptives are commonly used by women athletes. However, their effect on athletic performance is unclear. Objectives: To examine the effects of a moderate dose, triphasic oral contraceptive on measures of athletic performance in highly trained women athletes. Methods: This is a double blind, placebo controlled trial in 14 women with ovulatory menstrual cycles and maximal aerobic capacity (VO2MAX) ≥50 ml/kg/min. Four measures of athletic performance were tested: VO2MAX, anaerobic capacity (anaerobic speed test), aerobic endurance (time to fatigue at 90% of VO2MAX), and isokinetic strength (Cybex II dynamometer). Height, weight, and six skinfold measurements were also recorded. All these observational tests were completed during both the follicular and mid-luteal phases of an ovulatory menstrual cycle. Cycle phases were confirmed by assaying plasma oestradiol and progesterone. Participants were subsequently randomly assigned to either a tricyclic oral contraceptive or placebo and retested in identical fashion (oral contraceptive phase). Results: Absolute and relative changes in VO2MAX from follicular to oral contraceptive phase decreased in the oral contraceptive group by 4.7%, whereas the placebo group showed a slight increase (+1.5%) over the same time period. Two of the women taking oral contraceptive had decreases of 4 and 9 ml/kg/min. In contrast, most women in the placebo group improved or maintained VO2MAX. There was also a significant increase in the sum of skinfolds in women taking oral contraceptive compared with those taking placebo (p<0.01). There were no significant changes in other physiological variables (maximum ventilation, heart rate, respiratory exchange ratio, packed cell volume) or measures of performance (anaerobic speed test, aerobic endurance, isokinetic strength) as a function of oral contraceptive treatment. Conclusions: The decrease in VO2MAX that occurs when oral contraceptive is taken may influence elite sporting performance in some women. Further studies are required to determine the mechanisms of this change. PMID:12893716

  19. Manganese Vanadate Chemistry in Hydrothermal BaF 2 Brines: Ba 3 Mn 2 (V 2 O 7 ) 2 F 2 and Ba 7 Mn 8 O 2 (VO 4 ) 2 F 23

    DOE PAGES

    Sanjeewa, Liurukara D.; McMillen, Colin D.; McGuire, Michael A.; ...

    2016-12-05

    We synthesized manganese vanadate fluorides using high-temperature hydrothermal techniques with BaF 2 as a mineralizer. Ba 3Mn 2(V 2O 7) 2F 2 crystallizes in space group C2/c and consists of dimers built from edge-sharing MnO 4F 2 trigonal prisms with linking V 2O 7 groups. Ba 7Mn 8O 2(VO 4) 2F 23 crystallizes in space group Cmmm, with a manganese oxyfluoride network built from edge- and corner-sharing Mn 2+/3+(O,F) 6 octahedra. The resulting octahedra form alternating Mn 2+ and Mn 2+/3+ layers separated by VO 4 tetrahedra. This latter compound exhibits a canted antiferromagnetic order below TN = 25 K.

  20. Imaging of immunolabeled membrane receptors in uncoated SEM specimens.

    PubMed

    Heinzmann, U; Reninger, A; Autrata, R; Höfler, H

    1994-01-01

    Epidermal growth factor receptors (EGFR) were labeled with 10 nm immunogold and examined on uncoated specimens of A431 human epidermoid carcinoma cells. A field emission gun and a high-sensitivity YAG ring detector were used to demonstrate the affinity labeling simultaneously in the secondary-electron (SE) and backscattered-electron (BSE) modes with a low accelerating voltage (Vo). At Vo = 2 kV, the SE and BSE signals were too weak to identify all markers, while at Vo = 3-7 kV labeling was observed unambiguously in both the SE and BSE modes with smaller and higher working distances. Increasing the Vo to above 7 kV sometimes provokes instability of the specimens. A Vo of > or = 10 kV produces charging artifacts in the SE image, but permits a BSE image of the gold markers providing additional topographic information. In conclusion, immunogold labeling can be used with good results for uncoated specimens.

  1. 1-Dimensional AgVO3 nanowires hybrid with 2-dimensional graphene nanosheets to create 3-dimensional composite aerogels and their improved electrochemical properties

    NASA Astrophysics Data System (ADS)

    Liang, Liying; Xu, Yimeng; Lei, Yong; Liu, Haimei

    2014-03-01

    Three-dimensional (3D) porous composite aerogels have been synthesized via an innovative in situ hydrothermal method assisted by a freeze-drying process. In this hybrid structure, one-dimensional (1D) AgVO3 nanowires are uniformly dispersed on two-dimensional (2D) graphene nanosheet surfaces and/or are penetrated through the graphene sheets, forming 3D porous composite aerogels. As cathode materials for lithium-ion batteries, the composite aerogels exhibit high discharge capacity, excellent rate capability, and good cycling stability.Three-dimensional (3D) porous composite aerogels have been synthesized via an innovative in situ hydrothermal method assisted by a freeze-drying process. In this hybrid structure, one-dimensional (1D) AgVO3 nanowires are uniformly dispersed on two-dimensional (2D) graphene nanosheet surfaces and/or are penetrated through the graphene sheets, forming 3D porous composite aerogels. As cathode materials for lithium-ion batteries, the composite aerogels exhibit high discharge capacity, excellent rate capability, and good cycling stability. Electronic supplementary information (ESI) available: Preparation, characterization, SEM images, XRD patterns, and XPS of AgVO3/GAs. See DOI: 10.1039/c3nr06899d

  2. Adhesion characteristics of VO2 ink film sintered by intense pulsed light for smart window

    NASA Astrophysics Data System (ADS)

    Youn, Ji Won; Lee, Seok-Jae; Kim, Kwang-Seok; Kim, Dae Up

    2018-05-01

    Progress in the development of energy-efficient coatings on glass has led to the research of smart windows that can modulate solar energy in response to an external stimulus like light, heat, or electricity. Thermochromic smart windows have attracted great interest because they provide highly visible transparency and intelligently controllable solar heat. VO2 has been widely used as coating material for thermochromism owing to its reversible metal-to-insulator transition near room temperature. However, unstable crystalline phases and expensive fabrication processes of VO2 films limit their facile application in smart windows. To overcome these restrictions, we manufactured nanoinks based on VO2 nanoparticles and fabricated films using spin coating and intense pulsed light (IPL) sintering on a quartz substrate. We examined adhesion between the VO2 nanoink films and the quartz substrate by varying the applied voltages and the number of pulses. The average adhesion of thin films increased to 83 and 108 N/m as the applied voltage during IPL sintering increased from 1400 to 2000 V. By increasing the number of pulses from 5 to 20, the adhesive strength increased from 83 to 94 N/m at 1400 V, and decreased from 108 to 96 N/m at 2000 V voltage.

  3. Complexes of oxovanadium(IV), dioxovanadium(V) and dioxouranium(VI) with aminoacids in aqueous solution

    NASA Astrophysics Data System (ADS)

    Lagrange, P.; Schneider, M.; Lagrange, J.

    1998-11-01

    The equilibria between three oxocations (VO2+, VO2+ and UO22+) and several ?- aminoacids (glycine, serine, asparagine, lysine, aspartic acid and glutamic acid) are studied in aqueous solution. Stoichiometry and stability of the complexes formed are determined from a combination of potentiometric and spectroscopic measurements. Solution structures of the different complexes are proposed based on the thermodynamic results. The oxovanadium(IV) complexes appear less stable than the corresponding dioxouranium(VI) and dioxovanadium(V) complexes. VO2+ can be bound to only one ligand to form monodentate or chelate complexes. UO22+ and VO2+ cations may be chelated by one or two ligands. Les équilibres entre trois oxocations, VO2+, VO2+ et UO22+ et plusieurs α-aminoacides, glycine, sérine, asparagine, lysine et acides aspartique et glutamique, sont étudiés en solution aqueuse par potentiométrie couplée à la spectrophotométrie. Les complexes de VO2+ sont moins stables que les complexes de VO2+ et UO22+ de même stoechiométrie. VO2+ ne peut se lier qu'à un seul ligand pour former soit des complexes monodentés, soit des chélates. UO22+ et VO2+ peuvent être chélatés par un ou deux ligands. Des structures hypothétiques en solution sont proposées.

  4. Comparison of distribution and toxicity following repeated oral dosing of different vanadium oxide nanoparticles in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Eun-Jung, E-mail: pejtoxic@hanmail.net

    Vanadium is an important ultra-trace element derived from fuel product combustion. With the development of nanotechnology, vanadium oxide nanoparticles (VO NPs) have been considered for application in various fields, thus the possibility of release into the environment and human exposure is also increasing. Considering that verification of bioaccumulation and relevant biological responses are essential for safe application of products, in this study, we aimed to identify the physicochemical properties that determine their health effects by comparing the biological effects and tissue distribution of different types of VO NPs in mice. For this, we prepared five types of VO NPs, commercialmore » (C)-VO{sub 2} and -V{sub 2}O{sub 5} NPs and synthetic (S)-VO{sub 2}, -V{sub 2}O{sub 3,} and -V{sub 2}O{sub 5} NPs. While the hydrodynamic diameter of the two types of C-VO NPs was irregular and impossible to measure, those of the three types of S-VO NPs was in the range of 125–170 nm. The S- and C-V{sub 2}O{sub 5} NPs showed higher dissolution rates compared to other VO NPs. We orally dosed the five types of VO NPs (70 and 210 μg/mouse, approximately 2 and 6 mg/kg) to mice for 28 days and compared their biodistribution and toxic effects. We found that S-V{sub 2}O{sub 5} and S-V{sub 2}O{sub 3} NPs more accumulated in tissues compared to other three types of VO NPs, and the accumulated level was in order of heart>liver>kidney>spleen. Additionally, tissue levels of redox reaction-related elements and electrolytes (Na{sup +}, K{sup +}, and Ca{sup 2+}) were most clearly altered in the heart of treated mice. Notably, all S- and C-VO NPs decreased the number of WBCs at the higher dose, while total protein and albumin levels were reduced at the higher dose of S-V{sub 2}O{sub 5} and S-V{sub 2}O{sub 3} NPs. Taken together, we conclude that the biodistribution and toxic effects of VO NPs depend on their dissolution rates and size (surface area). Additionally, we suggest that further studies are needed to clarify effects of VO NPs on functions of the heart and the immune system. - Highlights: • We used commercial (C)-VO{sub 2} and -V{sub 2}O{sub 5} and synthetic (S)-VO{sub 2}, -V{sub 2}O{sub 3,} and -V{sub 2}O{sub 5} NPs. • The S- and C-V{sub 2}O{sub 5} NPs showed higher dissolution rates compared to other VO NPs. • S-V{sub 2}O{sub 5} and S-V{sub 2}O{sub 3} NPs more accumulated in tissues compared to other types of VO NPs. • Redox reaction-related elements and electrolytes were clearly altered in the heart. • With decreased body weight, immune and blood-related factors influence by all VO NPs. • Biodistribution and toxicity of VO NPs depend on their dissolution rates and size.« less

  5. Research progress of VO2 thin film as laser protecting material

    NASA Astrophysics Data System (ADS)

    Liu, Zhiwei; Lu, Yuan; Hou, Dianxin

    2018-03-01

    With the development of laser technology, the battlefield threat of directional laser weapons is becoming more and more serious. The blinding and destruction caused by laser weapons on the photoelectric equipment is an important part of the current photo-electronic warfare. The research on the defense technology of directional laser weapons based on the phase transition characteristics of VO2 thin films is an important subject. The researches of VO2 thin films are summarized based on review these points: the preparation methods of VO2 thin films, phase transition mechanism, phase transition temperature regulating, interaction between VO2 thin films and laser, and the application prospect of vo2 thin film as laser protecting material. This paper has some guiding significance for further research on the VO2 thin films in the field of defense directional laser weapons.

  6. Template-free synthesis of vanadium oxides nanobelt arrays as high-rate cathode materials for lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Qin, Mulan; Liang, Qiang; Pan, Anqiang; Liang, Shuquan; Zhang, Qing; Tang, Yan; Tan, Xiaoping

    2014-12-01

    A facile hydrothermal route has been developed to fabricate the metastable VO2 (B) ultra-thin nanobelt arrays, which can be converted into V2O5 porous nanobelt arrays after calcinating VO2 (B) in air at 400 °C for 1 h. The influence of hydrothermal time to the crystallinity and morphology of the VO2 phase has been studied. A possible mechanism for the formation of VO2 nanobelt arrays has been proposed in this paper. As a cathode material for lithium ion batteries, the V2O5 nanobelt arrays show excellent rate capability and cycling stability. An initial discharge capacity of 142 mA h g-1 can be delivered at a current density of 50 mA g-1 with almost no capacity fading after 100 cycles. Even at a current density of 1000 mA g-1, they still exhibit the capacity of 130 mA h g-1 and superior capacity retention capability. The excellent electrochemical properties are attributed to the ultra-thin thickness and the porous structures of the nanobelts.

  7. Ytterbium- and neodymium-doped vanadate laser hose crystals having the apatite crystal structure

    DOEpatents

    Payne, Stephen A.; Kway, Wayne L.; DeLoach, Laura D.; Krupke, William F.; Chai, Bruce H. T.

    1994-01-01

    Yb.sup.3+ and Nd.sup.3+ doped Sr.sub.5 (VO.sub.4).sub.3 F crystals serve as useful infrared laser media that exhibit low thresholds of oscillation and high slope efficiencies, and can be grown with high optical quality. These laser media possess unusually high absorption and emission cross sections, which provide the crystals with the ability to generate greater gain for a given amount of pump power. Many related crystals such as Sr.sub.5 (VO.sub.4).sub.3 F crystals doped with other rare earths, transition metals, or actinides, as well as the many structural analogs of Sr.sub.5 (VO.sub.4).sub.3 F, where the Sr.sup.2+ and F.sup.- ions are replaced by related chemical species, have similar properties.

  8. Experimental and theoretical study of the reactions between neutral vanadium oxide clusters and ethane, ethylene, and acetylene.

    PubMed

    Dong, Feng; Heinbuch, Scott; Xie, Yan; Rocca, Jorge J; Bernstein, Elliot R; Wang, Zhe-Chen; Deng, Ke; He, Sheng-Gui

    2008-02-13

    Reactions of neutral vanadium oxide clusters with small hydrocarbons, namely C2H6, C2H4, and C2H2, are investigated by experiment and density functional theory (DFT) calculations. Single photon ionization through extreme ultraviolet (EUV, 46.9 nm, 26.5 eV) and vacuum ultraviolet (VUV, 118 nm, 10.5 eV) lasers is used to detect neutral cluster distributions and reaction products. The most stable vanadium oxide clusters VO2, V2O5, V3O7, V4O10, etc. tend to associate with C2H4 generating products V(m)O(n)C2H4. Oxygen-rich clusters VO3(V2O5)(n=0,1,2...), (e.g., VO3, V3O8, and V5O13) react with C2H4 molecules to cause a cleavage of the C=C bond of C2H4 to produce (V2O5)(n)VO2CH2 clusters. For the reactions of vanadium oxide clusters (V(m)O(n)) with C2H2 molecules, V(m)O(n)C2H2 are assigned as the major products of the association reactions. Additionally, a dehydration reaction for VO3 + C2H2 to produce VO2C2 is also identified. C2H6 molecules are quite stable toward reaction with neutral vanadium oxide clusters. Density functional theory calculations are employed to investigate association reactions for V2O5 + C2H(x). The observed relative reactivity of C2 hydrocarbons toward neutral vanadium oxide clusters is well interpreted by using the DFT calculated binding energies. DFT calculations of the pathways for VO3+C2H4 and VO3+C2H2 reaction systems indicate that the reactions VO3+C2H4 --> VO2CH2 + H2CO and VO3+C2H2 --> VO2C2 + H2O are thermodynamically favorable and overall barrierless at room temperature, in good agreement with the experimental observations.

  9. Abnormal end-tidal PO(2) and PCO(2) at the anaerobic threshold correlate well with impaired exercise gas exchange in patients with left ventricular dysfunction.

    PubMed

    Kano, Hiroto; Koike, Akira; Hoshimoto-Iwamoto, Masayo; Nagayama, Osamu; Sakurada, Koji; Suzuki, Takeya; Tsuneoka, Hidekazu; Sawada, Hitoshi; Aizawa, Tadanori; Wasserman, Karlman

    2012-01-01

    The aim of the present study was to compare the end-tidal O(2) pressure (PETO(2)) to end-tidal CO(2) pressure (PETCO(2)) in cardiac patients during rest and during 2 states of exercise: at anaerobic threshold (AT) and at peak. The purpose was to see which metabolic state, PETO(2) or PETCO(2), best correlated with exercise limitation. Thirty-eight patients with left ventricular (LV) ejection fraction <40% underwent cardiopulmonary exercise testing (CPX). PETO(2) and PETCO(2) were measured during CPX, along with peak O(2) uptake (VO(2)), AT, slope of the increase in ventilation (VE) relative to the increase in CO(2) output (VCO(2)) (VE vs. VCO(2) slope), and the ratio of the increase in VO(2) to the increase in work rate (ΔVO(2)/ΔWR). Both PETO(2) and PETCO(2) measured at AT were best correlated with peakVO(2), AT, ΔVO(2)/ΔWR and VE vs. VCO(2) slope. PETO(2) at AT correlated with reduced peak VO(2) (r=-0.60), reduced AT (r=-0.52), reduced ΔVO(2)/ΔWR (r=-0.55) and increased VE vs. VCO(2) slope (r=0.74). PETCO(2) at AT correlated with reduced peak VO(2) (r=0.67), reduced AT (r=0.61), reduced ΔVO(2)/ΔWR (r=0.58) and increased VE vs. VCO(2) slope (r=-0.80). PETCO(2) and PETO(2) at AT correlated with peak VO(2), AT and ΔVO(2)/ΔWR, but best correlated with increased VE vs. VCO(2) slope. PETO(2) and PETCO(2) at AT can be used as a prime index of impaired cardiopulmonary function during exercise in patients with LV failure.

  10. Electronic structure and insulating gap in epitaxial VO 2 polymorphs

    DOE PAGES

    Lee, Shinbuhm; Meyer, Tricia L.; Sohn, Changhee; ...

    2015-12-24

    Here, determining the origin of the insulating gap in the monoclinic VO 2(M1) is a long-standing issue. The difficulty of this study arises from the simultaneous occurrence of structural and electronic transitions upon thermal cycling. Here, we compare the electronic structure of the M1 phase with that of single crystalline insulating VO 2(A) and VO 2(B) thin films to better understand the insulating phase of VO 2. As these A and B phases do not undergo a structural transition upon thermal cycling, we comparatively study the origin of the gap opening in the insulating VO 2 phases. By x-ray absorptionmore » and optical spectroscopy, we find that the shift of unoccupied t 2g orbitals away from the Fermi level is a common feature, which plays an important role for the insulating behavior in VO 2 polymorphs. The distinct splitting of the half-filled t 2g orbital is observed only in the M1 phase, widening the bandgap up to ~0.6 eV. Our approach of comparing all three insulating VO 2 phases provides insight into a better understanding of the electronic structure and the origin of the insulating gap in VO 2.« less

  11. Vacancy-oxygen defects in p-type Si1-xGex

    NASA Astrophysics Data System (ADS)

    Sgourou, E. N.; Londos, C. A.; Chroneos, A.

    2014-10-01

    Oxygen-vacancy defects and, in particular, the VO pairs (known as A-centers) are common defects in silicon (Si) with a deleterious impact upon its properties. Although oxygen-vacancy defects have been extensively studied in Si there is far less information about their properties in p-type doped silicon germanium (Si1-xGex). Here, we use Fourier transform infrared spectroscopy to determine the production and evolution of oxygen-vacancy defects in p-type Si1-xGex. It was determined that the increase of Ge content affects the production and the annealing behavior of the VO defect as well as its conversion to the VO2 defect. In particular, both the VO production and the VO annealing temperature are reduced with the increase of Ge. The conversion ratio [VO2]/[VO] also decreases with the increase of x, although the ratios [VO3]/[VO2] and [VO4]/[VO3] show a tendency to increase for larger Ge contents. The results are discussed in view of recent experimental and theoretical studies in Si and Si1-xGex.

  12. Controllable synthesis of ultrathin vanadium oxide nanobelts via an EDTA-mediated hydrothermal process

    NASA Astrophysics Data System (ADS)

    Yu-Xiang, Qin; Cheng, Liu; Wei-Wei, Xie; Meng-Yang, Cui

    2016-02-01

    Ultrathin VO2 nanobelts with rough alignment features are prepared on the induction layer-coated substrates by an ethylenediaminetetraacetic acid (EDTA)-mediated hydrothermal process. EDTA acts as a chelating reagent and capping agent to facilitate the one-dimensional (1D) preferential growth of ultrathin VO2 nanobelts with high crystallinities and good uniformities. The annealed induction layer and concentration of EDTA are found to play crucial roles in the formation of aligned and ultrathin nanobelts. Variation in EDTA concentration can change the VO2 morphology of ultrathin nanobelts into that of thick nanoplates. Mild annealing of ultrathin VO2 nanobelts at 350 °C in air results in the formation of V2O5 nanobelts with a nearly unchanged ultrathin structure. The nucleation and growth mechanism involved in the formations of nanobelts and nanoplates are proposed. The ethanol gas sensing properties of the V2O5 nanobelt networks-based sensor are investigated in a temperature range from 100 °C to 300 °C over ethanol concentrations ranging from 3 ppm to 500 ppm. The results indicate that the V2O5 nanobelt network sensor exhibits high sensitivity, good reversibility, and fast response-recovery characteristics with an optimal working temperature of 250 °C. Project supported by the National Natural Science Foundation of China (Grant Nos. 61274074, 61271070, and 61574100).

  13. Running Performance, VO2max, and Running Economy: The Widespread Issue of Endogenous Selection Bias.

    PubMed

    Borgen, Nicolai T

    2018-05-01

    Studies in sport and exercise medicine routinely use samples of highly trained individuals in order to understand what characterizes elite endurance performance, such as running economy and maximal oxygen uptake VO 2max . However, it is not well understood in the literature that using such samples most certainly leads to biased findings and accordingly potentially erroneous conclusions because of endogenous selection bias. In this paper, I review the current literature on running economy and VO 2max , and discuss the literature in light of endogenous selection bias. I demonstrate that the results in a large part of the literature may be misleading, and provide some practical suggestions as to how future studies may alleviate endogenous selection bias.

  14. Solution-Processed VO2-SiO2 Composite Films with Simultaneously Enhanced Luminous Transmittance, Solar Modulation Ability and Anti-Oxidation property

    PubMed Central

    Zhao, Lili; Miao, Lei; Liu, Chengyan; Li, Chao; Asaka, Toru; Kang, Yipu; Iwamoto, Yuji; Tanemura, Sakae; Gu, Hui; Su, Huirong

    2014-01-01

    Recently, researchers spare no efforts to fabricate desirable vanadium dioxide (VO2) film which provides simultaneously high luminous transmittance and outstanding solar modulation ability, yet progress towards the optimization of one aspect always comes at the expense of the other. Our research devotes to finding a reproducible economic solution-processed strategy for fabricating VO2-SiO2 composite films, with the aim of boosting the performance of both aspects. Compare to VO2 film, an improvement of 18.9% (from 29.6% to 48.5%) in the luminous transmittance as well as an increase of 6.0% (from 9.7% to 15.7%) in solar modulation efficiency is achieved when the molar ratio of Si/V attains 0.8. Based on the effective medium theory, we simulate the optical spectra of the composite films and the best thermochromic property is obtained when the filling factor attains 0.5, which is consistent with the experimental results. Meanwhile, the improvement of chemical stability for the composite film against oxidation has been confirmed. Tungsten is introduced to reduce the phase transition temperature to the ambient temperature, while maintain the thermochromism required for application as smart window. Our research set forth a new avenue in promoting practical applications of VO2-based thermochromic fenestration. PMID:25384345

  15. Solution-Processed VO2-SiO2 Composite Films with Simultaneously Enhanced Luminous Transmittance, Solar Modulation Ability and Anti-Oxidation property

    NASA Astrophysics Data System (ADS)

    Zhao, Lili; Miao, Lei; Liu, Chengyan; Li, Chao; Asaka, Toru; Kang, Yipu; Iwamoto, Yuji; Tanemura, Sakae; Gu, Hui; Su, Huirong

    2014-11-01

    Recently, researchers spare no efforts to fabricate desirable vanadium dioxide (VO2) film which provides simultaneously high luminous transmittance and outstanding solar modulation ability, yet progress towards the optimization of one aspect always comes at the expense of the other. Our research devotes to finding a reproducible economic solution-processed strategy for fabricating VO2-SiO2 composite films, with the aim of boosting the performance of both aspects. Compare to VO2 film, an improvement of 18.9% (from 29.6% to 48.5%) in the luminous transmittance as well as an increase of 6.0% (from 9.7% to 15.7%) in solar modulation efficiency is achieved when the molar ratio of Si/V attains 0.8. Based on the effective medium theory, we simulate the optical spectra of the composite films and the best thermochromic property is obtained when the filling factor attains 0.5, which is consistent with the experimental results. Meanwhile, the improvement of chemical stability for the composite film against oxidation has been confirmed. Tungsten is introduced to reduce the phase transition temperature to the ambient temperature, while maintain the thermochromism required for application as smart window. Our research set forth a new avenue in promoting practical applications of VO2-based thermochromic fenestration.

  16. Oxygen uptake and blood metabolic responses to a 400-m run.

    PubMed

    Hanon, Christine; Lepretre, Pierre-Marie; Bishop, David; Thomas, Claire

    2010-05-01

    This study aimed to investigate the oxygen uptake and metabolic responses during a 400-m run reproducing the pacing strategy used in competition. A portable gas analyser was used to measure the oxygen uptake (VO2) of ten specifically trained runners racing on an outdoor track. The tests included (1) an incremental test to determine maximal VO2 (VO2max) and the velocity associated with VO2(max) (v - VO2max), (2) a maximal 400-m (400T) and 3) a 300-m running test (300T) reproducing the exact pacing pattern of the 400T. Blood lactate, bicarbonate concentrations [HCO3(-)], pH and arterial oxygen saturation were analysed at rest and 1, 4, 7, 10 min after the end of the 400 and 300T. The peak VO2 recorded during the 400T corresponded to 93.9 +/- 3.9% of VO2max and was reached at 24.4 +/- 3.2 s (192 +/- 22 m). A significant decrease in VO2 (P < 0.05) was observed in all subjects during the last 100 m, although the velocity did not decrease below v - VO2max. The VO2 in the last 5 s was correlated with the pH (r = 0.86, P < 0.0005) and [HCO3(-)] (r = 0.70, P < 0.05) measured at the end of 300T. Additionally, the velocity decrease observed in the last 100 m was inversely correlated with [HCO3(-)] and pH at 300T (r = -0.83, P < 0.001, r = -0.69, P < 0.05, respectively). These track running data demonstrate that acidosis at 300 m was related to both the VO2 response and the velocity decrease during the final 100 m of a 400-m run.

  17. Diagnostic value of the six-minute walk test (6MWT) in grown-up congenital heart disease (GUCH): Comparison with clinical status and functional exercise capacity.

    PubMed

    Kehmeier, Eva S; Sommer, Margot H; Galonska, Anika; Zeus, Tobias; Verde, Pablo; Kelm, Malte

    2016-01-15

    Exercise testing for the assessment of functional capacity plays an important role in long-term follow-up of GUCH patients. CPX is the favored modality for decision-making recommended in the current guidelines. In contrast to this complex method, the 6 MWT is a simple, easy-to-perform, safe, and commonly available exercise test. Although well-established in various cardiopulmonary diseases, the diagnostic impact of the 6 MWT in GUCH patients is not known so far. 102 GUCH patients were evaluated by 6 MWT and CPX simultaneously. Clinical symptoms were assessed, according to the NYHA classification. Additionally, an echocardiography study, and selected cardiac blood tests (N-terminal pro-brain natriuretic peptide (NT-proBNP), high-sensitive Troponin T) were performed. Ranges of six-minute walk distance (6 MWD) and peak oxygen consumption (peakVO2) were 116-765 m and 6.4-36.2 ml/kg/min, respectively. 6 MWD and peakVO2 showed a close correlation (r=0.72, 95% CI, 0.63 to 0.79). Patients with a peakVO2 of ≤ 15.5 ml/kg/min were excellently identified by 6 MWT (c-value=0.82). A cut-off value of 482 m was optimal to predict reduced peakVO2. In multivariate regression analysis, 6 MWD and NYHA class were identified as relevant predictors of peakVO2. In subgroup analysis, Eisenmenger patients achieved the shortest 6 MWD (280, SD 178 m). In our study population of GUCH patients, the 6 MWD shows a close correlation to peakVO2, and an excellent prediction of reduced peakVO2. Thus, it seems to be an easy-to-perform and reliable screening parameter to evaluate functional capacity of these patients (Controlled Clinical Trials number, NCT02193243). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Estimated Prestroke Peak VO2 Is Related to Circulating IGF-1 Levels During Acute Stroke.

    PubMed

    Mattlage, Anna E; Rippee, Michael A; Abraham, Michael G; Sandt, Janice; Billinger, Sandra A

    2017-01-01

    Background Insulin-like growth factor-1 (IGF-1) is neuroprotective after stroke and is regulated by insulin-like binding protein-3 (IGFBP-3). In healthy individuals, exercise and improved aerobic fitness (peak oxygen uptake; peak VO 2 ) increases IGF-1 in circulation. Understanding the relationship between estimated prestroke aerobic fitness and IGF-1 and IGFBP-3 after stroke may provide insight into the benefits of exercise and aerobic fitness on stroke recovery. Objective The purpose of this study was to determine the relationship of IGF-1 and IGFBP-3 to estimated prestroke peak VO 2 in individuals with acute stroke. We hypothesized that (1) estimated prestroke peak VO 2 would be related to IGF-1 and IGFBP-3 and (2) individuals with higher than median IGF-1 levels will have higher estimated prestroke peak VO 2 compared to those with lower than median levels. Methods Fifteen individuals with acute stroke had blood sampled within 72 hours of hospital admission. Prestroke peak VO 2 was estimated using a nonexercise prediction equation. IGF-1 and IGFBP-3 levels were quantified using enzyme-linked immunoassay. Results Estimated prestroke peak VO 2 was significantly related to circulating IGF-1 levels (r = .60; P = .02) but not IGFBP-3. Individuals with higher than median IGF-1 (117.9 ng/mL) had significantly better estimated aerobic fitness (32.4 ± 6.9 mL kg -1 min -1 ) than those with lower than median IGF-1 (20.7 ± 7.8 mL kg -1 min -1 ; P = .03). Conclusions Improving aerobic fitness prior to stroke may be beneficial by increasing baseline IGF-1 levels. These results set the groundwork for future clinical trials to determine whether high IGF-1 and aerobic fitness are beneficial to stroke recovery by providing neuroprotection and improving function. © The Author(s) 2016.

  19. Estimation of the rate of oxygen consumption of the common eider duck (Somateria mollissima), with some measurements of heart rate during voluntary dives.

    PubMed

    Hawkins, P A; Butler, P J; Woakes, A J; Speakman, J R

    2000-09-01

    The relationship between heart rate (f(H)) and rate of oxygen consumption (V(O2)) was established for a marine diving bird, the common eider duck (Somateria mollissima), during steady-state swimming and running exercise. Both variables increased exponentially with speed during swimming and in a linear fashion during running. Eleven linear regressions of V(O2) (ml kg(-1 )min(-1)) on f(H) (beats min(-1)) were obtained: five by swimming and six by running the birds. The common regression was described by V(O2)=10.1 + 0.15f(H) (r(2)=0.46, N=272, P<0.0001). The accuracy of this relationship for predicting mean V(O2) was determined for a group of six birds by recording f(H) continuously over a 2-day period and comparing estimated V(O2) obtained using the common regression with (i) V(O2) estimated using the doubly labelled water technique (DLW) and (ii) V(O2) measured using respirometry. A two-pool model produced the most accurate estimated V(O2) using DLW. Because of individual variability within mean values of V(O2) estimated using both techniques, there was no significant difference between mean V(O2) estimated using f(H) or DLW and measured V(O2) values (P>0.2), although individual errors were substantially less when f(H) was used rather than DLW to estimate V(O2). Both techniques are, however, only suitable for estimating mean V(O2) for a group of animals, not for individuals. Heart rate and behaviour were monitored during a bout of 63 voluntary dives by one female bird in an indoor tank 1.7 m deep. Tachycardia occurred both in anticipation of and following each dive. Heart rate decreased before submersion but was above resting values for the whole of the dive cycle. Mean f(H) at mean dive duration was significantly greater than f(H) while swimming at maximum sustainable surface speeds. Heart rate was used to estimate mean V(O2) during the dive cycle and to predict aerobic dive limit (ADL) for shallow dives.

  20. Core-shell VO2@TiO2 nanorods that combine thermochromic and photocatalytic properties for application as energy-saving smart coatings

    PubMed Central

    Li, Yamei; Ji, Shidong; Gao, Yanfeng; Luo, Hongjie; Kanehira, Minoru

    2013-01-01

    Vanadium dioxide (VO2) is a Mott phase transition compound that can be applied as a thermochromic smart material for energy saving and comfort, and titanium dioxide (TiO2) is a well-known photocatalyst for self-cleaning coatings. In this paper, we report a VO2@TiO2 core-shell structure, in which the VO2 nanorod core exhibits a remarkable modulation ability for solar infrared light, and the TiO2 anatase shell exhibits significant photocatalytic degradation of organic dye. In addition, the TiO2 overcoating not only increased the luminous transmittance of VO2 based on an antireflection effect, but also modified the intrinsic colour of VO2 films from yellow to light blue. The TiO2 also enhanced the chemical stability of VO2 against oxidation. This is the first report of such a single nanoparticle structure with both thermochromic and photocatalytic properties that offer significant potential for creating a multifunctional smart coating. PMID:23546301

  1. Core-shell VO2@TiO2 nanorods that combine thermochromic and photocatalytic properties for application as energy-saving smart coatings.

    PubMed

    Li, Yamei; Ji, Shidong; Gao, Yanfeng; Luo, Hongjie; Kanehira, Minoru

    2013-01-01

    Vanadium dioxide (VO2) is a Mott phase transition compound that can be applied as a thermochromic smart material for energy saving and comfort, and titanium dioxide (TiO2) is a well-known photocatalyst for self-cleaning coatings. In this paper, we report a VO2@TiO2 core-shell structure, in which the VO2 nanorod core exhibits a remarkable modulation ability for solar infrared light, and the TiO2 anatase shell exhibits significant photocatalytic degradation of organic dye. In addition, the TiO2 overcoating not only increased the luminous transmittance of VO2 based on an antireflection effect, but also modified the intrinsic colour of VO2 films from yellow to light blue. The TiO2 also enhanced the chemical stability of VO2 against oxidation. This is the first report of such a single nanoparticle structure with both thermochromic and photocatalytic properties that offer significant potential for creating a multifunctional smart coating.

  2. Metabolic Rate and Ground Reaction Force During Motorized and Non-Motorized Treadmill Exercise

    NASA Technical Reports Server (NTRS)

    Everett, Meghan E.; Loehr, James A.; DeWitt, John K.; Laughlin, Mitzi; Lee, Stuart M. C.

    2010-01-01

    PURPOSE: To measure vertical ground reaction force (vGRF) and oxygen consumption (VO2) at several velocities during exercise using a ground-based version of the ISS treadmill in the M and NM modes. METHODS: Subjects (n = 20) walked or ran at 0.89, 1.34, 1.79, 2.24, 2.68, and 3.12 m/s while VO2 and vGRF data were collected. VO2 was measured using open-circuit spirometry (TrueOne 2400, Parvo-Medics). Data were averaged over the last 2 min of each 5-min stage. vGRF was measured in separate 15-s bouts at 125 Hz using custom-fitted pressure-sensing insoles (F-Scan Sport Sensors, Tekscan, Inc). A repeated-measures ANOVA was used to test for differences in VO2 and vGRF between M and NM and across speeds. Significance was set at P < 0.05. RESULTS: Most subjects were unable to exercise for 5 min at treadmill speeds above 1.79 m/s in the NM mode; however, vGRF data were obtained for all subjects at each speed in both modes. VO2 was approx.40% higher during NM than M exercise across treadmill speeds. vGRF increased with treadmill speed but was not different between modes. CONCLUSION: Higher VO2 with no change in vGRF suggests that the additional metabolic cost associated with NM treadmill exercise is accounted for in the horizontal forces required to move the treadmill belt. Although this may limit the exercise duration at faster speeds, high-intensity NM exercise activates the hamstrings and plantarflexors, which are not specifically targeted or well protected by other in-flight countermeasures.

  3. Characterization of thermochromic VO2 (prepared at 250 °C) in a wide temperature range by spectroscopic ellipsometry

    NASA Astrophysics Data System (ADS)

    Houska, J.; Kolenaty, D.; Rezek, J.; Vlcek, J.

    2017-11-01

    The paper deals with thermochromic VO2 prepared by reactive high-power impulse magnetron sputtering and characterized by spectroscopic ellipsometry. We focus on the dispersion of optical constants in a wide temperature range and on the transmittance predicted using the optical constants. While the thermochromic behavior of VO2 in itself has been reported previously (particularly above the room temperature, RT), in this paper we present (i) optical properties achieved at a low deposition temperature of 250 °C and without any substrate bias voltage (which dramatically increases the application potential of the coating) and (ii) changes of these properties not only above but also below RT (down to -30 °C). The properties include very low (for VO2) extinction coefficient at RT (0.10 at 550 nm), low transition temperature of around or even below 50 °C (compared to the frequently cited 68 °C) and high modulation of the predicted infrared transmittance (e.g. 39% at -30 °C, 30% at RT and 3.4% above the transition temperature at 2000 nm for a 100 nm thick coating on glass). The results are important for the design of thermochromic coatings, and pathways for their preparation under industry-friendly conditions, for various technological applications.

  4. Electric field induced metal-insulator transition in VO2 thin film based on FTO/VO2/FTO structure

    NASA Astrophysics Data System (ADS)

    Hao, Rulong; Li, Yi; Liu, Fei; Sun, Yao; Tang, Jiayin; Chen, Peizu; Jiang, Wei; Wu, Zhengyi; Xu, Tingting; Fang, Baoying

    2016-03-01

    A VO2 thin film has been prepared using a DC magnetron sputtering method and annealing on an F-doped SnO2 (FTO) conductive glass substrate. The FTO/VO2/FTO structure was fabricated using photolithography and a chemical etching process. The temperature dependence of the I-V hysteresis loop for the FTO/VO2/FTO structure has been analyzed. The threshold voltage decreases with increasing temperature, with a value of 9.2 V at 20 °C. The maximum transmission modulation value of the FTO/VO2/FTO structure is 31.4% under various temperatures and voltages. Optical modulation can be realized in the structure by applying an electric field.

  5. Simulated swimming: a useful tool for evaluation the VO2 max of swimmers in the laboratory.

    PubMed Central

    Kimura, Y; Yeater, R A; Martin, R B

    1990-01-01

    This study was designed to develop a simulated swimming exercise (SS) so that peak VO2 would be assessed on swimmers in a laboratory setting. The subjects assumed a prone position on an incline bench and performed arm cranking on a Monark Rehab Trainer while performing a flutter kick against tension supplied by elastic cords. The SS test was compared to four peak VO2 tests: treadmill running (RN), tethered swimming (TW), bicycle ergometry (B), and arm cranking (AC). Eleven male varsity swimmers underwent each of the five VO2 max tests, and maximal cardiorespiratory indicators (HR, VE, VO2, O2 pulse, and RQ) were measured. The percentage of peak VO2 obtained during SS was compared to RN, TW, B, and AC. The SS test achieved 78 percent of RN, 91 percent of TW, 81 percent of B, and 124 percent of AC. There were no significant differences in VO2 in ml/kg.min between SS and TW. As expected, RN and B were significantly higher, while AC was lower. Ten subjects performed the SS test twice on two separate days within one week. The reliability of VO2 max in ml/kg.min was 0.95. the validity of VO2 max in ml/kg.min in the SS test vs. RN was 0.68. The SS test is reliable and can be used as effectively as TW to assess the VO2 max of swimmers in a laboratory setting. PMID:2078808

  6. Localized surface plasmon resonance modulation of totally encapsulated VO2/Au/VO2 composite structure

    NASA Astrophysics Data System (ADS)

    Liang, Jiran; Guo, Jinbang; Zhao, Yirui; Zhang, Ying; Su, Tianyu

    2018-07-01

    We design and fabricate a totally encapsulated VO2/Au/VO2 composite structure which is aimed to improve the tunability of the localized surface plasmon resonance (LSPR) peak. In this work, the structure will ensure all the Au NPs’ resonant electric field area is filled with VO2. The modulation range of the totally encapsulated structure is larger than that of the semi-coated structure. To further improve the modulation range, we also explore the VO2 thickness dependence of the structure’s LSPR modulation. With the increase of the top layer VO2 thin film thickness, the modulation range becomes larger. When the thickness is about 80 nm, the absorption peak achieves a largest shift of 112 nm. FDTD solution and equivalent model of series capacitor are used to explain the phenomenon. These results will contribute to the area of metamaterial electromagnetic wave absorber and other fields.

  7. Localized surface plasmon resonance modulation of totally encapsulated VO2/Au/VO2 composite structure.

    PubMed

    Liang, Jiran; Guo, Jinbang; Zhao, Yirui; Zhang, Ying; Su, Tianyu

    2018-07-06

    We design and fabricate a totally encapsulated VO 2 /Au/VO 2 composite structure which is aimed to improve the tunability of the localized surface plasmon resonance (LSPR) peak. In this work, the structure will ensure all the Au NPs' resonant electric field area is filled with VO 2 . The modulation range of the totally encapsulated structure is larger than that of the semi-coated structure. To further improve the modulation range, we also explore the VO 2 thickness dependence of the structure's LSPR modulation. With the increase of the top layer VO 2 thin film thickness, the modulation range becomes larger. When the thickness is about 80 nm, the absorption peak achieves a largest shift of 112 nm. FDTD solution and equivalent model of series capacitor are used to explain the phenomenon. These results will contribute to the area of metamaterial electromagnetic wave absorber and other fields.

  8. Transparent optically vanadium dioxide thermochromic smart film fabricated via electrospinning technique

    NASA Astrophysics Data System (ADS)

    Lu, Yuan; Xiao, Xiudi; Cao, Ziyi; Zhan, Yongjun; Cheng, Haoliang; Xu, Gang

    2017-12-01

    The monoclinic phase vanadium dioxide VO2 (M) based transparent thermochromic smart films were firstly fabricated through heat treatment of opaque VO2-based composite nanofibrous mats, which were deposited on the glass substrate via electrospinning technique. Noteworthily, the anti-oxidation property of VO2 smart film was improved due to inner distribution of VO2 in the polymethylmethacrylate (PMMA) nanofibers, and the composite mats having water contact angle of 165° determined itself good superhydrophobic property. Besides, PMMA nanofibrous mats with different polymer concentrations demonstrated changeable morphology and fiber diameter. The VO2 nanoparticles having diameter of 30-50 nm gathered and exhibited ellipse-like or belt-like structure. Additionally, the solar modulation ability of PMMA-VO2 composite smart film was 6.88% according to UV-Vis-NIR spectra. The research offered a new notion for fabricating transparent VO2 thermochromic material.

  9. Effect of W addition on the electrical switching of VO{sub 2} thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajeswaran, Bharathi, E-mail: rajeswaran.bharathi@gmail.com, E-mail: rbharathi@mrc.iisc.ernet.in; Umarji, Arun M.

    2016-03-15

    Vanadium Oxide has been a frontrunner in the field of oxide electronics because of its metal-insulator transition (MIT). The interplay of different structures of VO{sub 2} has played a crucial role in deciding the magnitude of the first order MIT. Substitution doping has been found to introduce different polymorphs of VO{sub 2}. Hence the role of substitution doping in stabilizing the competing phases of VO{sub 2} in the thin film form remains underexplored. Consequently there have been reports both discounting and approving such a stabilization of competing phases in VO{sub 2}. It is reported in the literature that the bandwidthmore » of the hysteresis and transition temperature of VO{sub 2} can be tuned by substitutional doping of VO{sub 2} with W. In this work, we have adopted a novel technique called, Ultrasonic Nebulized Spray Pyrolysis of Aqueous Combustion Mixture (UNSPACM) to deposit VO{sub 2} and W- doped VO{sub 2} as thin films. XRD and Raman spectroscopy were used to investigate the role of tungsten on the structure of VO{sub 2} thin films. Morphology of the thin films was found to be consisting of globular and porous nanoparticles of size ∼ 20 nm. Transition temperature decreased with the addition of W. We found that for 2.0 at % W doping in VO{sub 2}, the transition temperature has reduced from 68 {sup o} C to 25 {sup o} C. It is noted that W-doping in the process of reducing the transition temperature, alters the local structure and also increases room temperature carrier concentration.« less

  10. Effects of high-intensity interval training on cardiometabolic risk factors in overweight/obese women.

    PubMed

    Smith-Ryan, Abbie E; Trexler, Eric T; Wingfield, Hailee L; Blue, Malia N M

    2016-11-01

    The purpose of this study was to evaluate two practical interval training protocols on cardiorespiratory fitness, lipids and body composition in overweight/obese women. Thirty women (mean ± SD; weight: 88.1 ± 15.9 kg; BMI: 32.0 ± 6.0 kg · m(2)) were randomly assigned to ten 1-min high-intensity intervals (90%VO2 peak, 1 min recovery) or five 2-min high-intensity intervals (80-100% VO2 peak, 1 min recovery) or control. Peak oxygen uptake (VO2 peak), peak power output (PPO), body composition and fasting blood lipids were evaluated before and after 3 weeks of training, completed 3 days per week. Results from ANCOVA analyses demonstrated no significant training group differences for any primary variables (P > 0.05). When training groups were collapsed, 1MIN and 2MIN resulted in a significant increase in PPO (∆18.9 ± 8.5 watts; P = 0.014) and time to exhaustion (∆55.1 ± 16.4 s; P = 0.001); non-significant increase in VO2 peak (∆2.36 ± 1.34 ml · kg(-)(1) · min(-)(1); P = 0.185); and a significant decrease in fat mass (FM) (-∆1.96 ± 0.99 kg; P = 0.011). Short-term interval exercise training may be effective for decreasing FM and improving exercise tolerance in overweight and obese women.

  11. Tuning phase transition temperature of VO2 thin films by annealing atmosphere

    NASA Astrophysics Data System (ADS)

    Liu, Xingxing; Wang, Shao-Wei; Chen, Feiliang; Yu, Liming; Chen, Xiaoshuang

    2015-07-01

    A simple new way to tune the optical phase transition temperature of VO2 films was proposed by only controlling the pressure of oxygen during the annealing process. Vanadium films were deposited on glass by a large-scale magnetron sputtering coating system and then annealed in appropriate oxygen atmosphere to form the VO2 films. The infrared transmission change (at 2400 nm) is as high as 58% for the VO2 thin film on the glass substrate, which is very good for tuning infrared radiation and energy saving as smart windows. The phase transition temperature of the films can be easily tuned from an intrinsic temperature to 44.7 °C and 40.2 °C on glass and sapphire by annealing oxygen pressure, respectively. The mechanism is: V3+ ions form in the film when under anaerobic conditions, which can interrupt the V4+ chain and reduce the phase transition temperature. The existence of V3+ ions has been observed by x-ray photoelectron spectroscopy (XPS) experiments as proof.

  12. Prognostic impact of peakVO2-changes in stable CHF on chronic beta-blocker treatment.

    PubMed

    Frankenstein, L; Nelles, M; Hallerbach, M; Dukic, D; Fluegel, A; Schellberg, D; Katus, H A; Remppis, A; Zugck, C

    2007-11-15

    Peak oxygen uptake (pVO2) is used for risk stratification in chronic heart failure (CHF), but little is known about the prognostic impact of pVO2-changes in patients on chronic beta-blocker (BBL) therapy. We therefore prospectively evaluated individual pVO2-changes at a 6-month interval in patients all receiving BBL. 194 patients with stable CHF on stable medication were included (V1) and underwent clinical evaluation and exercise testing. Testing was repeated (V2) at 5.7+/-1.5 months after V1 and patients were followed >12 months after V2. Death or hospitalisation due to cardiac reasons was the predefined EP (EPP, end-point positive; n=62; EPN, end-point negative; n=113). Initial characteristics did not differ between EPP and EPN. Multivariate cox regression analysis revealed that change of pVO2 (EPP: -0.6+/-2.6 ml/kg min; EPN: +2.5+/-3.3 ml/kg min; p<0.001) was independent to pVO2, LVEF, NTproBNP and NYHA at V2 for prediction of the combined end-point during follow-up. An increase of pVO2 by 10% was identified as an adequate cut-off value for risk stratification and ROC-analysis showed the significant incremental prognostic value of the determination of pVO2 changes in combination with pVO2. Serial measurements of pVO2 yield additional information for risk stratification in clinically homogenous CHF patients receiving BBL. This is the first study demonstrating this fact within a narrow predefined interval with all patients on BBL.

  13. Loading and concurrent synchronous whole-body vibration interaction increases oxygen consumption during resistance exercise.

    PubMed

    Serravite, Daniel H; Edwards, David; Edwards, Elizabeth S; Gallo, Sara E; Signorile, Joseph F

    2013-01-01

    Exercise is commonly used as an intervention to increase caloric output and positively affect body composition. A major challenge is the low compliance often seen when the prescribed exercise is associated with high levels of exertion. Whole-body vibration (WBV) may allow increased caloric output with reduced effort; however, there is limited information concerning the effect of WBV on oxygen consumption (VO2). Therefore, this study assessed the synergistic effects of resistance training and WBV on VO2. We examined VO2 at different loads (0%, 20%, and 40% body weight (BW)) and vibration intensities (No vibration (NV), 35HZ, 2-3mm (35L), 50Hz, 57mm (50H)) in ten men (26.5 ± 5.1 years). Data were collected during different stages (rest, six 30s sets of squatting, and recovery). Repeated measures ANOVA showed a stage x load x vibration interaction. Post hoc analysis revealed no differences during rest; however, a significant vibration x load interaction occurred during exercise. Both 35L and 50H produced greater VO2 than NV at a moderate load of 20%BW. Although 40%BW produced greater VO2 than 20%BW or 0%BW using NV, no significant difference in VO2 was seen among vibratory conditions at 40%BW. Moreover, no significant differences were seen between 50H and 35L at 20%BW and NV at 40%BW. During recovery there was a main effect for load. Post hoc analyses revealed that VO2 at 40%BW was significantly higher than 20%BW or 0%BW, and 20%BW produced higher VO2 than no load. Minute-by-minute analysis revealed a significant impact on VO2 due to load but not to vibratory condition. We conclude that the synergistic effect of WBV and active squatting with a moderate load is as effective at increasing VO2 as doubling the external load during squatting without WBV. Key PointsSynchronous whole body vibration in conjunction with moderate external loading (app 20% BW) can increase oxygen consumption to the same extent as heavier loading (40% BW) during performance of the parallel squat.While the application of synchronous whole body vibration had no effect on recovery oxygen, under bot vibratory and non-vibratory conditions, the heavier the external load the greater the recovery oxygen consumption levels.Regardless of vibratory condition, during the squatting exercise bout 40% BW produced higher heart rates than 20%BW or 0% BW, and 20% BW produced higher heart rates than 0% BW.There were strong trends toward higher heart rates in both vibratory conditions (50 Hz, 5-6mm; 35 Hz, 2-3 mm) than in the non-vibratory condition regardless of external loading.

  14. Switchable vanadium dioxide (VO2) metamaterials fabricated from tungsten doped vanadia-based colloidal nanocrystals

    NASA Astrophysics Data System (ADS)

    Paik, Taejong; Hong, Sung-Hoon; Gordon, Thomas; Gaulding, Ashley; Kagan, Cherie; Murray, Christopher

    2013-03-01

    We report the fabrication of thermochromic VO2-based metamaterials using solution-processable colloidal nanocrystals. Vanadium-based nanoparticles are prepared through a non-hydrolytic reaction, resulting in stable colloidal dispersions in solution. Thermochromic nanocrystalline VO2 thin-films are prepared via rapid thermal annealing of colloidal nanoparticles coated on a variety of substrates. Nanostructured VO2 can be patterned over large areas by nanoimprint lithography. Precise control of tungsten (W) doping concentration in colloidal nanoparticles enables tuning of the phase transition temperature of the nanocrystalline VO2 thin-films. W-doped VO2 films display a sharp temperature dependent phase transition, similar to the undoped VO2 film, but at lower temperatures tunable with the doping level. By sequential coating of doped VO2 with different doping concentrations, we fabricate ?smart? multi-layered VO2 films displaying multiple phase transition temperatures within a single structure, allowing for dynamic modulation of the metal-dielectric layered structure. The optical properties programmed into the layered structure are switchable with temperature, which provides additional degrees of freedom to design tunable optical metamaterials. This work is supported by the US Office of Naval Research Multidisciplinary University Research Initiative (MURI) program grant number ONR-N00014-10-1-0942.

  15. Discovery of Overcoating Metal Oxides on Photoelectrode for Water Splitting by Automated Screening.

    PubMed

    Saito, Rie; Miseki, Yugo; Nini, Wang; Sayama, Kazuhiro

    2015-10-12

    We applied an automated semiconductor synthesis and screen system to discover overcoating film materials and optimize coating conditions on the BiVO4/WO3 composite photoelectrode to enhance stability and photocurrent. Thirteen metallic elements for overcoating oxides were examined with various coating amounts. The stability of the BiVO4/WO3 photoelectrode in a highly concentrated carbonate electrolyte aqueous solution was significantly improved by overcoating with Ta2O5 film, which was amorphous and porous when calcined at 550 °C. The photocurrent for the water oxidation reaction was only minimally inhibited by the presence of the Ta2O5 film on the BiVO4/WO3 photoelectrode.

  16. Oxygen consumption of elite distance runners on an anti-gravity treadmill®.

    PubMed

    McNeill, David K P; Kline, John R; de Heer, Hendrick D; Coast, J Richard

    2015-06-01

    Lower body positive pressure (LBPP), or 'anti-gravity' treadmills® have become increasingly popular among elite distance runners. However, to date, few studies have assessed the effect of body weight support (BWS) on the metabolic cost of running among elite runners. This study evaluated how BWS influenced the relationship between velocity and metabolic cost among 6 elite male distance runners. Participants ran three- 16 minute tests consisting of 4 stages of 4 minutes at 8, 7, 6 and 5 min·mile(-1) pace (3.35, 3.84, 4.47 and 5.36 m·s(-1)), while maintaining an aerobic effort (Respiratory Exchange Ratio ≤1.00). One test was run on a regular treadmill, one on an anti-gravity treadmill with 40% BWS and one with 20% BWS being provided. Expired gas data were collected and regression equations used to determine and compare slopes. Significant decreases in oxygen uptake (V̇O2) were found with each increase in BWS (p < 0.001). At 20% BWS, the average decrease in net VO2 was greater than proportional (34%), while at 40% BWS, the average net reduction in VO2 was close to proportional (38%). Across velocities, the slope of the relationship between VO2 and velocity (ΔV̇O2/Δv) was steeper with less support. The slopes at both the 20% and 40% BWS conditions were similar, especially when compared to the regular treadmill. Variability in VO2 between athletes was much greater on the LBPP treadmill and was greater with increased levels of BWS. In this study we evaluated the effect of body weight support on V̇O2 among elite distance runners. We have shown that oxygen uptake decreased with support, but not in direct proportion to that support. Further, because of the high variability in oxygen uptake between athletes on the LBPP treadmill, prediction equations may not be reliable and other indicators (heart rate, perceived exertion or directly measured oxygen uptake) should be used to guide training intensity when training on the LBPP treadmill. Key pointsWith increasing amounts of body weight-support (BWS), the slope of the relationship between velocity and oxygen consumption (ΔVO2/Δv) decreases significantly. This means the change in oxygen consumption (VO2) is significantly smaller over a given change in velocity at higher amounts of BWS.There is a non-linear decrease in VO2 with increasing BWS. As such, with each increment in the amount of BWS provided, the reduction in VO2 becomes increasingly smaller.This paper provides first of its kind data on the effects of BWS on the cost of running among highly trained, elite runners. The outcomes of this study are in line with previous findings among non-elite runners.

  17. Structures, physicochemical and cytoprotective properties of new oxidovanadium(IV) complexes -[VO(mIDA)(dmbipy)]·1.5H2O and [VO(IDA)(dmbipy)]·2H2O

    NASA Astrophysics Data System (ADS)

    Drzeżdżon, Joanna; Jacewicz, Dagmara; Wyrzykowski, Dariusz; Inkielewicz-Stępniak, Iwona; Sikorski, Artur; Tesmar, Aleksandra; Chmurzyński, Lech

    2017-09-01

    New oxidovanadium(IV) complexes with a modification of the ligand in the VO2+ coordination sphere were synthesized. [VO(mIDA)(dmbipy)]•1.5H2O and [VO(IDA)(dmbipy)]•2H2O were obtained as dark green crystals and grey-green powder, respectively (mIDA = N-methyliminodiacetic anion, IDA = iminodiacetic anion, dmbipy = 4,4‧-dimethoxy-2,2‧-dipyridyl). The crystal structure of [VO(mIDA)(dmbipy)]·1.5H2O has been determined by the X-ray diffraction method. The studies of structure of [VO(mIDA)(dmbipy)]•1.5H2O have shown that this compound occurs in the crystal as two rotational conformers. Furthermore, the stability constants of [VO(mIDA)(dmbipy)]•1.5H2O and [VO(IDA)(dmbipy)]•2H2O complexes in aqueous solutions were studied by using the potentiometric titration method and, consequently, determined using the Hyperquad2008 program. Moreover, the title complexes were investigated as antioxidant substances. The impact of the structure modification in the VO2+ complexes on the radical scavenging activity has been studied. The ability to scavenge the superoxide radical by two complexes - [VO(mIDA)(dmbipy)]·1.5H2O and [VO(IDA)(dmbipy)]·2H2O was studied by cyclic voltammetry (CV) and nitrobluetetrazolium (NBT) methods. The title complexes were also examined by the spectrophotometric method as scavengers of neutral organic radical - 1,1-diphenyl-2-picrylhydrazyl (DPPH•) and radical cation - 2,2'-azinobis-(3-ethylbenzothiazoline)-6-sulfonic acid (ABTS•+). Furthermore, the biological properties of two oxidovanadium(IV) complexes were investigated in relation to its cytoprotective properties by the MTT and LDH tests based on the hippocampal HT22 neuronal cell line during the oxidative damage induced by hydrogen peroxide. Finally, the results presented in this paper have shown that the both new oxidovanadium(IV) complexes with the 4,4‧-dimethoxy-2,2‧-dipyridyl ligand can be treated as the cytoprotective substances.

  18. Facile synthesis, phase transition, optical switching and oxidation resistance properties of belt-like VO{sub 2}(A) and VO{sub 2}(M) with a rectangular cross section

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yifu; Huang, Yanfen; Zhang, Juecheng

    2012-08-15

    Highlights: ► Belt-like VO{sub 2}(A) with a rectangular cross section was synthesized. ► The formation mechanism of belt-like VO{sub 2}(A) was proposed. ► Belt-like VO{sub 2}(M) was prepared by the irreversible transformation of VO{sub 2}(A). ► VO{sub 2}(A) and VO{sub 2}(M) can be used as the optical switching materials. ► VO{sub 2}(A) and VO{sub 2}(M) have good oxidation resistance below 400 °C in air. -- Abstract: Belt-like VO{sub 2}(A) with a rectangular cross section (VA-RCS) was successfully synthesized using V{sub 2}O{sub 5}, H{sub 2}C{sub 2}O{sub 4}·2H{sub 2}O and H{sub 2}O as the starting materials by a facile hydrothermal approach. Somemore » synthetic parameters, such as, the reaction time, reaction temperature and concentration of H{sub 2}C{sub 2}O{sub 4}·2H{sub 2}O, were systematically investigated to control the fabrication of belt-like VA-RCS. The formation mechanism of belt-like VA-RCS was proposed. Subsequently, belt-like VO{sub 2}(M) with a rectangular cross section (VM-RCS) was prepared by the irreversible transformation of VA-RCS at 700 °C for 2 h under the inert atmosphere. The phase transition temperature (T{sub c}) of VA-RCS and VM-RCS was evaluated by DSC test. The optical switching properties of VA-RCS and VM-RCS were studied by the variable-temperature infrared spectra, and it was found that the as-obtained VA-RCS and VM-RCS could be used as the optical switching materials. Furthermore, the oxidation resistance properties of VA-RCS and VM-RCS were investigated by TGA, indicating that they have good thermal stability and oxidation resistance below 400 °C in air.« less

  19. Changes in Ventilatory Response to Exercise in Trained Athletes: Respiratory Physiological Benefits Beyond Cardiovascular Performance.

    PubMed

    di Paco, Adriano; Dubé, Bruno-Pierre; Laveneziana, Pierantonio

    2017-05-01

    The beneficial impact of an 8-month competitive season on the ventilatory profile response to exercise in soccer players has never been evaluated. Ventilatory profile (evaluated by determining individual tidal volume [V T ] relative to minute ventilation [V E ] inflection points during exercise) and metabolic responses to incremental exercise were evaluated in 2 professional soccer teams before and after an 8-month competitive season. No differences between teams in anthropometric characteristics or in resting cardiopulmonary variables, included oxygen uptake (VO 2 ) and heart rate (HR), before and during the competitive season were found. At iso-speed, there were overall improvements in carbon dioxide output (VCO 2 ), V E /VO 2 , V E /VCO 2 , V E and respiratory frequency (fR) during the season. The V T /V E inflection points 1 and 2 occurred with greater exercise time, HR, VO 2 , VCO 2 , V E and V T during the competitive season. Despite very high baseline performance and a negligible improvement in VO 2 , an 8-month competitive season improved ventilatory profile response to exercise in elite athletes. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Influence of oxygen uptake kinetics on physical performance in youth soccer.

    PubMed

    Doncaster, Greg; Marwood, Simon; Iga, John; Unnithan, Viswanath

    2016-09-01

    To examine the relationship between oxygen uptake kinetics (VO2 kinetics) and physical measures associated with soccer match play, within a group of highly trained youth soccer players. Seventeen highly trained youth soccer players (age: 13.3 ± 0.4 year, self-assessed Tanner stage: 3 ± 1) volunteered for the study. Players initially completed an incremental treadmill protocol to exhaustion, to establish gaseous exchange threshold (GET) and VO2max (59.1 ± 5.4 mL kg(-1) min(-1)). On subsequent visits, players completed a step transition protocol from rest-moderate-intensity exercise, followed by an immediate transition, and from moderate- to severe-intensity exercise (moderate: 95 % GET, severe: 60 %∆), during which VO2 kinetics were determined. Physical soccer-based performance was assessed using a maximal Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1) and via GPS-derived measures of physical soccer performance during soccer match play, three 2 × 20 min, 11 v 11 matches, to gain measures of physical performance during soccer match play. Partial correlations revealed significant inverse relationships between the unloaded-to-moderate transition time constant (tau) and: Yo-Yo IR1 performance (r = -0.58, P = 0.02) and GPS variables [total distance (TD): r = -0.64, P = 0.007, high-speed running (HSR): r = -0.64, P = 0.008 and high-speed running efforts (HSReff): r = -0.66, P = 0.005]. Measures of VO2 kinetics are related to physical measures associated with soccer match play and could potentially be used to distinguish between those of superior physical performance, within a group of highly trained youth soccer players.

  1. Intrinsic motivation in two exercise interventions: Associations with fitness and body composition.

    PubMed

    Thøgersen-Ntoumani, Cecilie; Shepherd, Sam O; Ntoumanis, Nikos; Wagenmakers, Anton J M; Shaw, Christopher S

    2016-02-01

    To examine the motivational process through which increases in aerobic capacity and decreases in total body fat are achieved during high-intensity intermittent training (HIT) and moderate-intensity continuous training (MICT) interventions. Eighty-seven physically inactive adults (65% women, age = 42 ± 12, BMI = 27.67 ± 4.99 kg/m²) took part in a 10-week randomized intervention testing group-based HIT, operationalized as repeated sprints of 15-60 s interspersed with periods of recovery cycling ≤ 25 min/session, 3 sessions/wk⁻¹, or MICT, operationalized as cycling at constant workload of ∼65% maximum aerobic capacity (VO2max, 30-45 min/session⁻¹, 5 sessions/wk⁻¹. Assessments of VO2max and total body fat were made pre- and postintervention. Motivation variables were assessed midintervention and class attendance was monitored throughout. Path analysis was employed, controlling for treatment arm and baseline values of VO2max and total body fat. The 2 groups differed in adherence only, favoring HIT. Baseline VO2max predicted intrinsic motivation midintervention. Intrinsic motivation predicted program adherence, which in turn predicted increases in VO2max and decreases in total body fat by the end of the study. Intrinsic motivation in HIT and MICT is positively linked to adherence to these programs, which can facilitate improvements in fitness and body composition. (c) 2016 APA, all rights reserved).

  2. Chemical bond parameters and photoluminescence of a natural-white-light Ca{sub 9}La(VO{sub 4}){sub 7}:Tm{sup 3+},Eu{sup 3+} with one O{sup 2−}→V{sup 5+} charge transfer and dual f-f transition emission centers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ling; Liu, Xiao Guang; Department of Physics, Pukyong National University, Busan 608-737

    2015-01-15

    The relationship between the photoluminescence properties and the crystal structure of undoped, Eu{sup 3+} or/ and Tm{sup 3+} singly or codoped Ca{sub 9}La(VO{sub 4}){sub 7} (CLaVO) samples was discussed. Under the excitation of UV light, CLaVO:Tm{sup 3+}, CLaVO, and CLaVO:Eu{sup 3+} exhibit the characteristic emissions of Tm{sup 3+} ({sup 1}G{sub 4}→{sup 3}H{sub 6}, blue), O{sup 2−}→V{sup 5+} charge transfer (CT), and Eu{sup 3+} ({sup 5}D{sub 0}→{sup 7}F{sub 2}, red), respectively. By adjusting the doping concentration of Tm{sup 3+} and Eu{sup 3+} ions in CLaVO, a natural white emission in a single composition with the color temperature at 6181 K wasmore » obtained. Based on the dielectric theory of complex crystal, the chemical bond parameters of La-O and V-O bonds were quantitatively calculated. The standard deviation of environmental factor of every bond (EFSD), which can be expressed as σ(h{sub e{sub i}})=√((1/N)∑{sub i=1}{sup N}(h{sub e{sub i}}−μ){sup 2}) (h{sub e{sub i}}=(f{sub c{sub i}}α{sub b{sub i}}){sup 1/2}Q{sub B{sub i}} and μ=(1/N)∑{sub i=1}{sup N}h{sub e{sub i}}), was proposed to quantitatively express the distortion degree of VO{sub 4}{sup 3−} from that of an ideal tetrahedron. The maximum change of EFSD comes from the [VO{sub 4}]{sup −} tetrahedra in CLaVO sample by comparison with that of EFSD of isostructural Ca{sub 9}Gd(VO{sub 4}){sub 7}. This is possible the key reason that the undoped CLaVO sample has self-activated emission while the self-activated emission of its isostructural Ca{sub 9}Gd(VO{sub 4}){sub 7} sample cannot be found. The quantitative calculation also demonstrated that the broad excitation bands at 319 nm in CLaVO:Tm and at 335 nm in CLaVO:Eu were due to the O-V2 and O-V3 (overlap with O-V2) CT, not the CT energy of O{sup 2−}-Eu1{sup 3+} (O{sup 2−}-Tm1{sup 3+}), O{sup 2−}-Eu2{sup 3+} (O{sup 2−}-Tm2{sup 3+}), and O{sup 2−}-Eu3{sup 3+} (O{sup 2−}-Tm3{sup 3+}). The environmental factors surrounding the atoms V1, V2 and V3 were calculated to be 1.577, 1.6379 and 1.7554, respectively. It can be demonstrated that the excitation spectra at 319 nm for CLaVO:Tm and 335 nm for CLaVO:Eu came from the O-V2 and O-V3 CT, respectively. - Graphical abstracts: The relationship between the photoluminescence properties and the crystal structure of undoped, Eu{sup 3+} or/ and Tm{sup 3+} singly or codoped Ca{sub 9}La(VO{sub 4}){sub 7} (CLaVO) samples was discussed experimentally and theoretically. - Highlights: ●The photoluminescence properties of Ca{sub 9}La(VO{sub 4}){sub 7}:Eu, Tm were measured. ●The tunable color including white emission can be obtained. ●The important chemical bond parameters of O-V were calculated quantitatively. ●The standard deviation of environmental factor of every bond was proposed. ●The theoretical analysis of the self-activated emission for Ca{sub 9}La(VO{sub 4}){sub 7} was given.« less

  3. The slow component of O(2) uptake is not accompanied by changes in muscle EMG during repeated bouts of heavy exercise in humans.

    PubMed

    Scheuermann, B W; Hoelting, B D; Noble, M L; Barstow, T J

    2001-02-15

    1. We hypothesized that either the recruitment of additional muscle motor units and/or the progressive recruitment of less efficient fast-twitch muscle fibres was the predominant contributor to the additional oxygen uptake (VO2) observed during heavy exercise. Using surface electromyographic (EMG) techniques, we compared the VO2 response with the integrated EMG (iEMG) and mean power frequency (MPF) response of the vastus lateralis with the VO2 response during repeated bouts of moderate (below the lactate threshold, < LT) and heavy (above the lactate threshold, > LT) intensity cycle ergometer exercise. 2. Seven male subjects (age 29 +/- 7 years, mean +/- S.D.) performed three transitions to a work rate (WR) corresponding to 90 % LT and two transitions to a work rate that would elicit a VO2 corresponding to 50 % of the difference between peak VO2 and the LT (i.e. Delta50 %, > LT1 and > LT2). 3. The VO2 slow component was significantly reduced by prior heavy intensity exercise (> LT1, 410 +/- 196 ml min(-1); > LT2, 230 +/- 191 ml min-1). The time constant (tau), amplitude (A) and gain (DeltaVO2/DeltaWR) of the primary VO2 response (phase II) were not affected by prior heavy exercise when a three-component, exponential model was used to describe the V2 response. 4. Integrated EMG and MPF remained relatively constant and at the same level throughout both > LT1 and > LT2 exercise and therefore were not associated with the VO2 slow component. 5. These data are consistent with the view that the increased O2 cost (i.e. VO2 slow component) associated with performing heavy exercise is coupled with a progressive increase in ATP requirements of the already recruited motor units rather than to changes in the recruitment pattern of slow versus fast-twitch motor units. Further, the lack of speeding of the kinetics of the primary VO2 component with prior heavy exercise, thought to represent the initial muscle VO2 response, are inconsistent with O2 delivery being the limiting factor in V > O2 kinetics during heavy exercise.

  4. [New methods for determining the relative load due to physical effort of the human body].

    PubMed

    Szubert, Józef; Szubert, Sławomir; Koszada-Włodarczyk, Wiesława; Bortkiewicz, Alicja

    2014-01-01

    The relative physical load (% VO2max) is the quotient of oxygen uptake (Vo2) during physical effort and maximum oxygen uptake (VO2max) by the human body. For this purpose the stress test must be performed. The relative load shows a high correlation with minute ventilation, cardiac output, heart rate, stroke volume, increased concentrations of catecholamines in the blood, inner temperature, weight, height and human body surface area. The relative load is a criterion for the maximum workloads admissible for healthy and sick workers. Besides, the classification of effort can be more precise when based on the relative load than on the energy output. Based on our own and international empirical evidence and the laws of heat transfer and fluid mechanics, a model of temperature control system has been developed, involving the elements of human cardiovascular and respiratory systems. Using this model, we have been able to develop our own methods of determining the relative load, applying only the body core temperature (Tw) or heart rate within one minute (HR), body mass (m), height (H), and body surface area (AD) instead of VO,max. The values of the relative physical load (% VO2max) obtained by using our own methods do not differ significantly from those obtained by other methods and by other researchers. The developed methods for determining the relative physical load (% VO2max) do not require the exercise test to be performed, therefore, they may be considered (after verification in an experimental study) a feasible alternative to current methods.

  5. VO2max and ventilatory threshold of trained cyclists are not affected by 28-day L-arginine supplementation.

    PubMed

    Sunderland, Kyle L; Greer, Felicia; Morales, Jacobo

    2011-03-01

    The ergogenic effect of L-arginine on an endurance-trained population is not well studied. The few studies that have investigated L-arginine on this population have not been conducted in a laboratory setting or measured aerobic variables. The purpose of the current study is to determine if 28 days of L-arginine supplementation in trained male cyclists affects VO2max and ventilatory threshold (VT). Eighteen (18) endurance-trained male cyclists (mean ± SD, age: 36.3 ± 7.9 years; height: 182.4 ± 4.6 cm; and body mass: 79.5 ± 4.7 kg) performed a graded exercise test (GXT; 50 W + 25 W·min) before and after 28 days of supplementation with L-arginine (ARG; 2 × 6 g·d) or placebo (PLA; cornstarch). The GXT was conducted on the subject's own bicycle using the RacerMate CompuTrainer (Seattle, WA, USA). VO2 was continuously recorded using the ParvoMedics TrueOne 2400 metabolic cart (Salt Lake City, UT, USA) and VT was established by plotting the ventilatory equivalent for O2 (VE/VO2) and the ventilatory equivalent for CO2 (VE/VCO2) and identifying the point at which VE/VO2 increases with no substantial changes in VE/VCO2. L-arginine supplementation had no effect from initial VO2max (PL, 58.7 ± 7.1 ml·kg·min; ARG, 63.5 ± 7.3 ml·kg·min) to postsupplement VO2max (PL, 58.9 ± 6.0 ml·kg·min; ARG, 63.2 ± 7.2 ml·kg·min). Also, no effect was seen from initial VT (PL, 75.7 ± 4.6% VO2max; ARG, 76.0 ± 5.3% VO2max) to postsupplement VT (PL, 74.3 ± 8.1% VO2max; ARG, 74.2 ± 6.4% VO2max). These results indicate that L-arginine does not impact VO2max or VT in trained male cyclists.

  6. CNC Turning Technician. A Competency-Based Instructional System.

    ERIC Educational Resources Information Center

    Sloan, Kelly; Hilley, Robert

    This competency-based curriculum guide for instructing students in using computer numerically controlled (CNC) turning machines is one of a series of instructional guides for the machinist field developed in Oklahoma. Although developed jointly with Baxter Technologies Corporation and oriented toward the Baxter Vo-Tec 2000 Future Builder CNC…

  7. VO2 /TiN Plasmonic Thermochromic Smart Coatings for Room-Temperature Applications.

    PubMed

    Hao, Qi; Li, Wan; Xu, Huiyan; Wang, Jiawei; Yin, Yin; Wang, Huaiyu; Ma, Libo; Ma, Fei; Jiang, Xuchuan; Schmidt, Oliver G; Chu, Paul K

    2018-03-01

    Vanadium dioxide/titanium nitride (VO 2 /TiN) smart coatings are prepared by hybridizing thermochromic VO 2 with plasmonic TiN nanoparticles. The VO 2 /TiN coatings can control infrared (IR) radiation dynamically in accordance with the ambient temperature and illumination intensity. It blocks IR light under strong illumination at 28 °C but is IR transparent under weak irradiation conditions or at a low temperature of 20 °C. The VO 2 /TiN coatings exhibit a good integral visible transmittance of up to 51% and excellent IR switching efficiency of 48% at 2000 nm. These unique advantages make VO 2 /TiN promising as smart energy-saving windows. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. End-exercise ΔHHb/ΔVO2 and post-exercise local oxygen availability in relation to exercise intensity.

    PubMed

    Stöcker, F; Von Oldershausen, C; Paternoster, F K; Schulz, T; Oberhoffer, R

    2017-07-01

    Increased local blood supply is thought to be one of the mechanisms underlying oxidative adaptations to interval training regimes. The relationship of exercise intensity with local blood supply and oxygen availability has not been sufficiently evaluated yet. The aim of this study was to examine the effect of six different intensities (40-90% peak oxygen uptake, VO 2peak ) on relative changes in oxygenated, deoxygenated and total haemoglobin (ΔO 2 Hb, ΔHHb, ΔTHb) concentration after exercise as well as end-exercise ΔHHb/ΔVO 2 as a marker for microvascular O 2 distribution. Seventeen male subjects performed an experimental protocol consisting of 3 min cycling bouts at each exercise intensity in randomized order, separated by 5 min rests. ΔO 2 Hb and ΔHHb were monitored with near-infrared spectroscopy of the vastus lateralis muscle, and VO 2 was assessed. ΔHHb/ΔVO 2 increased significantly from 40% to 60% VO 2 peak and decreased from 60% to 90% VO 2 peak. Post-exercise ΔTHb and ΔO 2 Hb showed an overshoot in relation to pre-exercise values, which was equal after 40-60% VO 2peak and rose significantly thereafter. A plateau was reached following exercise at ≥80% VO 2peak . The results suggest that there is an increasing mismatch of local O 2 delivery and utilization during exercise up to 60% VO 2peak . This insufficient local O 2 distribution is progressively improved above that intensity. Further, exercise intensities of ≥80% VO 2peak induce highest local post-exercise O 2 availability. These effects are likely due to improved microvascular perfusion by enhanced vasodilation, which could be mediated by higher lactate production and the accompanying acidosis. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Facile fabrication of Ag3VO4/attapulgite composites for highly efficient visible light-driven photodegradation towards organic dyes and tetracycline hydrochloride

    NASA Astrophysics Data System (ADS)

    Luo, Yuting; Luo, Jie; Duan, Guorong; Liu, Xiaoheng

    2017-12-01

    An efficient one-dimensional attapulgite (ATP)-based photocatalyst, Ag3VO4/ATP nanocomposite, was fabricated by a facile deposition precipitation method with well-dispersed Ag3VO4 nanoparticles anchored on the surface of natural ATP fibers. X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), and UV-visible diffused reflectance spectroscopy (UV-vis DRS) were employed to investigate the morphologies, structure, and optical property of the prepared photocatalysts. The photocatalytic experiments indicated that the Ag3VO4/ATP nanocomposites exhibited enhanced visible light-driven photocatalytic activity towards the degradation of rhodamine B (RhB), methyl orange (MO), and tetracycline hydrochloride (TCH), of which the 20 wt% Ag3VO4/ATP sample showed superb photocatalytic performance. As demonstrated by N2 adsorption-desorption, photocurrent measurements, electrochemical impedance spectroscopy (EIS), and photoluminescence (PL) spectra analyses, the improved photocatalytic activity arose from the enlarged surface area, the facilitated charge transfer, and the suppressed recombination of photogenerated charge carriers in Ag3VO4/ATP system. Furthermore, radical scavengers trapping experiments and recycling tests were also conducted. This work gives a new insight into fabrication of highly efficient, stable, and cost-effective visible light-driven photocatalyst for practical application in wastewater treatment and environmental remediation.

  10. The Effect of Two Different Concurrent Training Programs on Strength and Power Gains in Highly-Trained Individuals

    PubMed Central

    Petré, Henrik; Löfving, Pontus; Psilander, Niklas

    2018-01-01

    The effects of concurrent strength and endurance training have been well studied in untrained and moderately-trained individuals. However, studies examining these effects in individuals with a long history of resistance training (RT) are lacking. Additionally, few studies have examined how strength and power are affected when different types of endurance training are added to an RT protocol. The purpose of the present study was to compare the effects of concurrent training incorporating either low-volume, high-intensity interval training (HIIT, 8-24 Tabata intervals at ~150% of VO2max) or high-volume, medium-intensity continuous endurance training (CT, 40-80 min at 70% of VO2max), on the strength and power of highly-trained individuals. Sixteen highly-trained ice-hockey and rugby players were divided into two groups that underwent either CT (n = 8) or HIIT (n = 8) in parallel with RT (2-6 sets of heavy parallel squats, > 80% of 1RM) during a 6-week period (3 sessions/wk). Parallel squat performance improved after both RT + CT and RT + HIIT (12 ± 8% and 14 ± 10% respectively, p < 0.01), with no difference between the groups. However, aerobic power (VO2max) only improved after RT + HIIT (4 ± 3%, p < 0.01). We conclude that strength gains can be obtained after both RT + CT and RT + HIIT in athletes with a prior history of RT. This indicates that the volume and/or intensity of the endurance training does not influence the magnitude of strength improvements during short periods of concurrent training, at least for highly-trained individuals when the endurance training is performed after RT. However, since VO2max improved only after RT + HIIT and this is a time efficient protocol, we recommend this type of concurrent endurance training. Key points Lower body maximal strength is improved after concurrent strength and endurance training in highly trained individuals. The magnitude of this strength improvement is not influenced by the type of endurance training, i.e. HIIT or CT. HIIT improves VO2max and is more time efficient than CT. HIIT is recommended to athletes when concurrently training for strength and endurance. PMID:29769816

  11. Effects of recovery mode (active vs. passive) on performance during a short high-intensity interval training program: a longitudinal study.

    PubMed

    Ben Abderrahman, Abderraouf; Zouhal, Hassane; Chamari, Karim; Thevenet, Delphine; de Mullenheim, Pierre-Yves; Gastinger, Steven; Tabka, Zouhair; Prioux, Jacques

    2013-06-01

    The aim of this longitudinal study was to compare two recovery modes (active vs. passive) during a seven-week high-intensity interval training program (SWHITP) aimed to improve maximal oxygen uptake ([Formula: see text]), maximal aerobic velocity (MAV), time to exhaustion (t lim) and time spent at a high percentage of [Formula: see text], i.e., above 90 % (t90 [Formula: see text]) and 95 % (t95 [Formula: see text]) of [Formula: see text]. Twenty-four adults were randomly assigned to a control group that did not train (CG, n = 6) and two training groups: intermittent exercise (30 s exercise/30 s recovery) with active (IEA, n = 9) or passive recovery (IEP, n = 9). Before and after seven weeks with (IEA and IEP) or without (CG) high-intensity interval training (HIT) program, all subjects performed a maximal graded test to determine their [Formula: see text] and MAV. Subsequently only the subjects of IEA and IEP groups carried out an intermittent exercise test consisting of repeating as long as possible 30 s intensive runs at 105 % of MAV alternating with 30 s active recovery at 50 % of MAV (IEA) or 30 s passive recovery (IEP). Within IEA and IEP, mean t lim and MAV significantly increased between the onset and the end of the SWHITP and no significant difference was found in t90 VO2max and t95 VO2max. Furthermore, before and after the SWHITP, passive recovery allowed a longer t lim for a similar time spent at a high percentage of VO2max. Finally, within IEA, but not in IEP, mean VO2max increased significantly between the onset and the end of the SWHITP both in absolute (p < 0.01) and relative values (p < 0.05). In conclusion, our results showed a significant increase in VO2max after a SWHITP with active recovery in spite of the fact that t lim was significantly longer (more than twice longer) with respect to passive recovery.

  12. Chemical composition of an aqueous oxalato-/citrato-VO(2+) solution as determinant for vanadium oxide phase formation.

    PubMed

    Peys, Nick; Maurelli, Sara; Reekmans, Gunter; Adriaensens, Peter; De Gendt, Stefan; Hardy, An; Van Doorslaer, Sabine; Van Bael, Marlies K

    2015-01-05

    Aqueous solutions of oxalato- and citrato-VO(2+) complexes are prepared, and their ligand exchange reaction is investigated as a function of the amount of citrate present in the aqueous solution via continuous-wave electron paramagnetic resonance (CW EPR) and hyperfine sublevel correlation (HYSCORE) spectroscopy. With a low amount of citrate, monomeric cis-oxalato-VO(2+) complexes occur with a distorted square-pyramidal geometry. As the amount of citrate increases, oxalate is gradually exchanged for citrate. This leads to (i) an intermediate situation of monomeric VO(2+) complexes with a mix of oxalate/citrate ligands and (ii) a final situation of both monomeric and dimeric complexes with exclusively citrato ligands. The monomeric citrato-VO(2+) complexes dominate (abundance > 80%) and are characterized by a 6-fold chelation of the vanadium(IV) ion by 4 RCO2(-) ligands at the equatorial positions and a H2O/R-OH ligand at the axial position. The different redox stabilities of these complexes, relative to that of dissolved O2 in the aqueous solution, is analyzed via (51)V NMR. It is shown that the oxidation rate is the highest for the oxalato-VO(2+) complexes. In addition, the stability of the VO(2+) complexes can be drastically improved by evacuation of the dissolved O2 from the solution and subsequent storage in a N2 ambient atmosphere. The vanadium oxide phase formation process, starting with the chemical solution deposition of the aqueous solutions and continuing with subsequent processing in an ambient 0.1% O2 atmosphere, differs for the two complexes. The oxalato-VO(2+) complexes turn into the oxygen-deficient crystalline VO2 B at 400 °C, which then turns into crystalline V6O13 at 500 °C. In contrast, the citrato-VO(2+) complexes form an amorphous film at 400 °C that crystallizes into VO2 M1 and V6O13 at 500 °C.

  13. Aerobic capacity of Peruvian Quechua: a test of the developmental adaptation hypothesis.

    PubMed

    Kiyamu, Melisa; Rivera-Chira, María; Brutsaert, Tom D

    2015-03-01

    High altitude natives are reported to have outstanding work capacity in spite of the challenge of oxygen transport and delivery in hypoxia. To evaluate the developmental effect of lifelong exposure to hypoxia on aerobic capacity, VO2peak was measured on two groups of Peruvian Quechua subjects (18-35 years), who differed in their developmental exposure to altitude. Male and female volunteers were recruited in Lima, Peru (150 m), and were divided in two groups, based on their developmental exposure to hypoxia, those: a) Born at sea-level individuals (BSL), with no developmental exposure to hypoxia (n = 34) and b) Born at high-altitude individuals (BHA) with full developmental exposure to hypoxia (n = 32), but who migrated to sea-level as adults (>16-years-old). Tests were conducted both in normoxia (BP = 750 mm Hg) and normobaric hypoxia at sea-level (BP = 750 mm Hg, FiO2  = 0.12, equivalent to 4,449 m), after a 2-month training period (in order to control for initial differences in physical fitness) at sea-level. BHA had a significantly higher VO2peak at hypoxia (40.31 ± 1.0 ml/min/kg) as compared to BSL (35.78 ± 0.96 ml/min/kg, P = 0.001), adjusting for sex. The decrease of VO2peak at HA relative to SL (ΔVO2peak ) was not different between groups, controlling for baseline levels (VO2peak at sea-level) and sex (BHA = 0.35 ± 0.04 l/min, BSL = 0.44 ± 0.04 l/min; P = 0.12). Forced vital capacity (controlling for height) and the residuals of VO2peak (controlling for weight) had a significant association in the BHA group only (r = 0.155; P = 0.031). In sum, results indicate that developmental exposure to altitude constitutes an important factor to determine superior exercise performance. © 2014 Wiley Periodicals, Inc.

  14. Prediction of Maximal Oxygen Uptake by Six-Minute Walk Test and Body Mass Index in Healthy Boys.

    PubMed

    Jalili, Majid; Nazem, Farzad; Sazvar, Akbar; Ranjbar, Kamal

    2018-05-14

    To develop an equation to predict maximal oxygen uptake (VO2max) based on the 6-minute walk test (6MWT) and body composition in healthy boys. Direct VO2max, 6-minute walk distance, and anthropometric characteristics were measured in 349 healthy boys (12.49 ± 2.72 years). Multiple regression analysis was used to generate VO2max prediction equations. Cross-validation of the VO2max prediction equations was assessed with predicted residual sum of squares statistics. Pearson correlation was used to assess the correlation between measured and predicted VO2max. Objectively measured VO2max had a significant correlation with demographic and 6MWT characteristics (R = 0.11-0.723, P < .01). Multiple regression analysis revealed the following VO2max prediction equation: VO2max (mL/kg/min) = 12.701 + (0.06 × 6-minute walk distance m ) - (0.732 × body mass index kg/m2 ) (R 2 = 0.79, standard error of the estimate [SEE] = 2.91 mL/kg/min, %SEE = 6.9%). There was strong correlation between measured and predicted VO2max (r = 0.875, P < .001). Cross-validation revealed minimal shrinkage (R 2 p = 0.78 and predicted residual sum of squares SEE = 2.99 mL/kg/min). This study provides a relatively accurate and convenient VO2max prediction equation based on the 6MWT and body mass index in healthy boys. This model can be used for evaluation of cardiorespiratory fitness of boys in different settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Graphene‐Nanowall‐Decorated Carbon Felt with Excellent Electrochemical Activity Toward VO2 +/VO2+ Couple for All Vanadium Redox Flow Battery

    PubMed Central

    Li, Wenyue; Zhang, Zhenyu; Bian, Haidong; Ng, Tsz‐Wai

    2015-01-01

    3D graphene‐nanowall‐decorated carbon felts (CF) are synthesized via an in situ microwave plasma enhanced chemical vapor deposition method and used as positive electrode for vanadium redox flow battery (VRFB). The carbon fibers in CF are successfully wrapped by vertically grown graphene nanowalls, which not only increase the electrode specific area, but also expose a high density of sharp graphene edges with good catalytic activities to the vanadium ions. As a result, the VRFB with this novel electrode shows three times higher reaction rate toward VO2 +/VO2+ redox couple and 11% increased energy efficiency over VRFB with an unmodified CF electrode. Moreover, this designed architecture shows excellent stability in the battery operation. After 100 charging–discharging cycles, the electrode not only shows no observable morphology change, it can also be reused in another battery and practical with the same performance. It is believed that this novel structure including the synthesis procedure will provide a new developing direction for the VRFB electrode. PMID:27774399

  16. Graphene-Nanowall-Decorated Carbon Felt with Excellent Electrochemical Activity Toward VO2+/VO2+ Couple for All Vanadium Redox Flow Battery.

    PubMed

    Li, Wenyue; Zhang, Zhenyu; Tang, Yongbing; Bian, Haidong; Ng, Tsz-Wai; Zhang, Wenjun; Lee, Chun-Sing

    2016-04-01

    3D graphene-nanowall-decorated carbon felts (CF) are synthesized via an in situ microwave plasma enhanced chemical vapor deposition method and used as positive electrode for vanadium redox flow battery (VRFB). The carbon fibers in CF are successfully wrapped by vertically grown graphene nanowalls, which not only increase the electrode specific area, but also expose a high density of sharp graphene edges with good catalytic activities to the vanadium ions. As a result, the VRFB with this novel electrode shows three times higher reaction rate toward VO 2 + /VO 2+ redox couple and 11% increased energy efficiency over VRFB with an unmodified CF electrode. Moreover, this designed architecture shows excellent stability in the battery operation. After 100 charging-discharging cycles, the electrode not only shows no observable morphology change, it can also be reused in another battery and practical with the same performance. It is believed that this novel structure including the synthesis procedure will provide a new developing direction for the VRFB electrode.

  17. Maximal Upper Body Strength and Oxygen Uptake are Associated with Performance in High-Level 200-M Sprint Kayakers.

    PubMed

    Pickett, Craig W; Nosaka, Kazunori; Zois, James; Hopkins, Will G; J, Anthony; Blazevich

    2017-12-27

    Current training and monitoring methods in sprint kayaking are based on the premise that upper-body muscular strength and aerobic power are both important for performance, but limited evidence exists to support this premise in high-level athletes. Relationships between measures of strength, maximal oxygen uptake (VO2max) and 200-m race times in kayakers competing at national-to-international levels were examined. Data collected from Australian Canoeing training camps and competitions for 7 elite, 7 national and 8 club level male sprint kayakers were analyzed for relationships between maximal isoinertial strength (3-RM bench press, bench row, chin-up and deadlift), VO2max on a kayak ergometer, and 200-m race time. Correlations between race time and bench press, bench row, chin-up, and VO2max were -0.80, -0.76, -0.73, -0.02 and 0.71, respectively (90% confidence limits ∼±0.17). The multiple correlation coefficient for 200-m race time with bench press and VO2max was 0.84. Errors in prediction of 200-m race time in regression analyses were extremely large (∼4%) in relation to the smallest important change of 0.3%. However, from the slopes of the regressions, the smallest important change could be achieved with a 1.4% (±0.5%) change in bench-press strength and a 0.9% (±0.5%) change in VO2max. Substantial relationships were found between upper-body strength or aerobic power and 200-m performances. These measures may not accurately predict individual performance times, but would be practicable for talent identification purposes. Training aimed at improving upper-body strength or aerobic power in lowerperforming athletes could also enhance the performance in 200-m kayak sprints.

  18. The alveolar to arterial oxygen partial pressure difference is associated with pulmonary diffusing capacity in heart failure patients.

    PubMed

    Morosin, Marco; Vignati, Carlo; Novi, Angela; Salvioni, Elisabetta; Veglia, Fabrizio; Alimento, Marina; Merli, Guido; Sciomer, Susanna; Sinagra, Gianfranco; Agostoni, Piergiuseppe

    2016-11-01

    In chronic heart failure (HF), the alveolar-capillary membrane undergoes a remodeling process that negatively affects gas exchange. In case of alveolar-capillary gas diffusion impairment, arterial desaturation (SaO 2 ) is rarely observed in HF patients. At play are 3 factors: overall pulmonary diffusing capacity (assessed as lung diffusion for CO, DLCO), global O 2 consumption (VO 2 ) and alveolar (A) to arterial (a) pO 2 gradient (AaDO 2 ). In 100 consecutive stable HF patients, DLCO, resting respiratory gases and arterial blood gases were measured to determine VO 2, paO 2 , pAO 2 and AaDO 2 . DLCO was poorly but significantly related to AaDO 2 . The correlation improved after correcting AaDO 2 for VO 2 (p<0.001, r=0.49). Both VO 2 and AaDO 2 were independently associated with DLCO (p<0.001). Patients with reduced DLCO showed no differences as regards paO 2 and pAO 2 . AaDO 2 /VO 2 showed a higher gradient in patients with lower DLCO. AaDO 2 increase and VO 2 reduction allow preventing low SaO 2 in HF patients with reduced DLCO. Accordingly, we suggest considering AaDO 2 and VO 2 combined and reporting AaDO 2 /VO 2 . Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Relationship between inflammatory markers of cardiovascular disease and VO2peak in asymptomatic females.

    PubMed

    Omran Simin, F; Narges, Z; Sajad, A; Parisa, Y; Omrani Vahid, F

    2013-04-01

    The objective of this study was to investigate the relationship between inflammatory markers of cardiovascular disease (IL-6 and acute-phase reactants) and VO2peak in asymptomatic females. Study subjects were females not affected by coronary heart diseases. Forty healthy female subjects (age, 45±4.2 years; height, 161±3.5 cm; weight, 65±3.1 kg; history of regular physical activity, 5.2±0.45 years) participated in this study Analysis of data was carried out by Pearson's correlation. Statistical analysis of data indicated a negative significant relationship between IL-6 and VO2peak (r=-0.48, r2=0.23, P<0.048), CRP and VO2peak (r=-0.40, r2= 0.16, P<0.002), fibrinogen and VO2peak (r=-0.42, r2=0.17, P<0.001), and WBC and VO2peak (r=-0.22, r2=0.04, P<0.044). In conclusion higher circulating levels of IL-6, CRP and fibrinogen are associated with lower VO2peak in females.

  20. Maximal oxygen uptake is associated with allele -202 A of insulin-like growth factor binding protein-3 (IGFBP3) promoter polymorphism and (CA)n tandem repeats of insulin-like growth factor IGF1 in Caucasians from Poland.

    PubMed

    Gronek, Piotr; Holdys, Joanna; Kryściak, Jakub; Wieliński, Dariusz; Słomski, Ryszard

    2014-01-01

    Physical fitness is a trait determined by multiple genes, and its genetic basis is modified by numerous environmental factors. The present study examines the effects of the (CA)n tandem repeats polymorphism in IGFI gene and SNP Alw21I restriction site -202 A>C polymorphism in IGF1BP3 on VO2max--a physiological index of aerobic capacity of high heritability. The study sample consisted of 239 (154 male and 85 female) students of the University School of Physical Education in Poznań and athletes practicing various sports, including members of the Polish national team. An association was found between -202 A/C polymorphism of IGFBP3 gene with VO2max in men. Higher VO2max values were attained by men with CC genotype, especially male athletes practicing endurance sports and sports featuring energy metabolism of aerobic/anaerobic character. A statistically significant influence of allele 188 and genotype 188/188 of tandem repeats (CA)n polymorphism of IGF1 gene on VO2max was found in women. Also, lower values of maximal oxygen uptake were noted in individuals with allele 186 or genotype 186/186, and higher VO2max values in athletes with allele 194.

  1. Lung function parameters improve prediction of VO2peak in an elderly population: The Generation 100 study.

    PubMed

    Hassel, Erlend; Stensvold, Dorthe; Halvorsen, Thomas; Wisløff, Ulrik; Langhammer, Arnulf; Steinshamn, Sigurd

    2017-01-01

    Peak oxygen uptake (VO2peak) is an indicator of cardiovascular health and a useful tool for risk stratification. Direct measurement of VO2peak is resource-demanding and may be contraindicated. There exist several non-exercise models to estimate VO2peak that utilize easily obtainable health parameters, but none of them includes lung function measures or hemoglobin concentrations. We aimed to test whether addition of these parameters could improve prediction of VO2peak compared to an established model that includes age, waist circumference, self-reported physical activity and resting heart rate. We included 1431 subjects aged 69-77 years that completed a laboratory test of VO2peak, spirometry, and a gas diffusion test. Prediction models for VO2peak were developed with multiple linear regression, and goodness of fit was evaluated. Forced expiratory volume in one second (FEV1), diffusing capacity of the lung for carbon monoxide and blood hemoglobin concentration significantly improved the ability of the established model to predict VO2peak. The explained variance of the model increased from 31% to 48% for men and from 32% to 38% for women (p<0.001). FEV1, diffusing capacity of the lungs for carbon monoxide and hemoglobin concentration substantially improved the accuracy of VO2peak prediction when added to an established model in an elderly population.

  2. Optical switching and photoluminescence in erbium-implanted vanadium dioxide thin films

    NASA Astrophysics Data System (ADS)

    Lim, Herianto; Stavrias, Nikolas; Johnson, Brett C.; Marvel, Robert E.; Haglund, Richard F.; McCallum, Jeffrey C.

    2014-03-01

    Vanadium dioxide (VO2) is under intensive consideration for optical switching due to its reversible phase transition, which features a drastic and rapid shift in infrared reflectivity. Classified as an insulator-to-metal transition, the phase transition in VO2 can be induced thermally, electrically, and optically. When induced optically, the transition can occur on sub-picosecond time scales. It is interesting to dope VO2 with erbium ions (Er3+) and observe their combined properties. The first excited-state luminescence of Er3+ lies within the wavelength window of minimal transmission-loss in silicon and has been widely utilized for signal amplification and generation in silicon photonics. The incorporation of Er3+ into VO2 could therefore result in a novel photonic material capable of simultaneous optical switching and amplification. In this work, we investigate the optical switching and photoluminescence in Er-implanted VO2 thin films. Thermally driven optical switching is demonstrated in the Er-implanted VO2 by infrared reflectometry. Photoluminescence is observed in the thin films annealed at ˜800 °C or above. In addition, Raman spectroscopy and a statistical analysis of switching hysteresis are carried out to assess the effects of the ion implantation on the VO2 thin films. We conclude that Er-implanted VO2 can function as an optical switch and amplifier, but with reduced switching quality compared to pure VO2.

  3. Removing the thermal component from heart rate provides an accurate VO2 estimation in forest work.

    PubMed

    Dubé, Philippe-Antoine; Imbeau, Daniel; Dubeau, Denise; Lebel, Luc; Kolus, Ahmet

    2016-05-01

    Heart rate (HR) was monitored continuously in 41 forest workers performing brushcutting or tree planting work. 10-min seated rest periods were imposed during the workday to estimate the HR thermal component (ΔHRT) per Vogt et al. (1970, 1973). VO2 was measured using a portable gas analyzer during a morning submaximal step-test conducted at the work site, during a work bout over the course of the day (range: 9-74 min), and during an ensuing 10-min rest pause taken at the worksite. The VO2 estimated, from measured HR and from corrected HR (thermal component removed), were compared to VO2 measured during work and rest. Varied levels of HR thermal component (ΔHRTavg range: 0-38 bpm) originating from a wide range of ambient thermal conditions, thermal clothing insulation worn, and physical load exerted during work were observed. Using raw HR significantly overestimated measured work VO2 by 30% on average (range: 1%-64%). 74% of VO2 prediction error variance was explained by the HR thermal component. VO2 estimated from corrected HR, was not statistically different from measured VO2. Work VO2 can be estimated accurately in the presence of thermal stress using Vogt et al.'s method, which can be implemented easily by the practitioner with inexpensive instruments. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. Integrating existing software toolkits into VO system

    NASA Astrophysics Data System (ADS)

    Cui, Chenzhou; Zhao, Yong-Heng; Wang, Xiaoqian; Sang, Jian; Luo, Ze

    2004-09-01

    Virtual Observatory (VO) is a collection of interoperating data archives and software tools. Taking advantages of the latest information technologies, it aims to provide a data-intensively online research environment for astronomers all around the world. A large number of high-qualified astronomical software packages and libraries are powerful and easy of use, and have been widely used by astronomers for many years. Integrating those toolkits into the VO system is a necessary and important task for the VO developers. VO architecture greatly depends on Grid and Web services, consequently the general VO integration route is "Java Ready - Grid Ready - VO Ready". In the paper, we discuss the importance of VO integration for existing toolkits and discuss the possible solutions. We introduce two efforts in the field from China-VO project, "gImageMagick" and "Galactic abundance gradients statistical research under grid environment". We also discuss what additional work should be done to convert Grid service to VO service.

  5. The fabrication and visible-near-infrared optical modulation of vanadium dioxide/silicon dioxide composite photonic crystal structure

    NASA Astrophysics Data System (ADS)

    Liang, Jiran; Li, Peng; Song, Xiaolong; Zhou, Liwei

    2017-12-01

    We demonstrated a visible and near-infrared light tunable photonic nanostructure, which is composed of vanadium dioxide (VO2) thin film and silicon dioxide (SiO2) ordered nanosphere arrays. The vanadium films were sputtered on two-dimensional (2D) SiO2 sphere arrays. VO2 thin films were prepared by rapid thermal annealing (RTA) method with different oxygen flow rates. The close-packed VO2 shell formed a continuous surface, the composition of VO2 films in the structure changed when the oxygen flow rates increased. The 2D VO2/SiO2 composite photonic crystal structure exhibited transmittance trough tunability and near-infrared (NIR) transmittance modulation. When the oxygen flow rate increased from 3 slpm to 4 slpm, the largest transmittance trough can be regulated from 904 to 929 nm at low temperature, the transmittance troughs also appear blue shift when the VO2 phase changes from insulator to metal. The composite nanostructure based on VO2 films showed visible transmittance tunability, which would provide insights into the glass color changing in smart windows.

  6. Atomic layer deposition of VO2 films with Tetrakis-dimethyl-amino vanadium (IV) as vanadium precursor

    NASA Astrophysics Data System (ADS)

    Lv, Xinrui; Cao, Yunzhen; Yan, Lu; Li, Ying; Song, Lixin

    2017-02-01

    VO2 thin films have been grown on Si(100) (VO2/Si) and fused silica substrates (VO2/SiO2) by atomic layer deposition (ALD) using tetrakis-dimethyl-amino vanadium (IV) (TDMAV) as a novel vanadium precursor and water as reactant gas. The quartz crystal microbalance (QCM) measurement was performed to study the ALD process of VO2 thin film deposition, and a constant growth rate of about 0.95 Å/cycle was obtained at the temperature range of 150-200 °C. XRD measurement was performed to study the influence of deposition temperature and post-annealing condition on the crystallization of VO2 films, which indicated that the films deposited between 150 and 200 °C showed well crystallinity after annealing at 475 °C for 100 min in Ar atmosphere. XPS measurement verified that the vanadium oxidation state was 4+ for both as-deposited film and post-annealed VO2/Si film. AFM was applied to study the surface morphology of VO2/Si films, which showed a dense polycrystalline film with roughness of about 1 nm. The resistance of VO2/Si films deposited between 150 °C and 200 °C as a function of temperature showed similar semiconductor-to-metal transition (SMT) characters with the transition temperature for heating branch (Tc,h) of about 72 °C, a hysteresis width of about 10 °C and the resistance change of two orders of magnitude. The increase of Tc,h compared with the bulk VO2 (68 °C) may be attributed to the tensile stress along the c-axis in the film. Transmittance measurement of VO2/SiO2 films showed typical thermochromic property with a NIR switching efficiency of above 50% at 2 μm across the transition.

  7. Determinants of Exercise Intolerance in Elderly Heart Failure Patients with Preserved Ejection Fraction

    PubMed Central

    Haykowsky, Mark J.; Brubaker, Peter H.; John, Jerry M.; Stewart, Kathryn P.; Morgan, Timothy M.; Kitzman, Dalane W.

    2011-01-01

    Objectives To determine the mechanisms responsible for reduced aerobic capacity (peak VO2) in heart failure patients with preserved ejection fraction (HFPEF). Background HFPEF is the predominant form of HF in older persons. Exercise intolerance is the primary symptom among patients with HFPEF and a major determinant of reduced quality of life. In contrast to patients with HF and reduced EF, the mechanism of exercise intolerance in HFPEF is less well understood. Methods Left ventricular volumes (2D echocardiography), cardiac output (CO), VO2 and calculated arterial-venous oxygen content difference (A-VO2 Diff) were measured at rest and during incremental, exhaustive upright cycle exercise in 48 HFPEF patients (age 69±6 years) and 25 healthy age-matched controls (HC). Results In HFPEF compared to HC, VO2 was reduced at peak exercise (mean±SE: 14.3±0.5 vs. 20.4±0.6 mL·kg min−1; p<0.0001) and was associated with a reduced peak CO (6.3±0.2 vs. 7.6±0.2 L·min−1, p<0.0001) and A-VO2 Diff (17±0.4 vs. 19±0.4 ml·dl−1, p<0.0007). The strongest independent predictor of peak VO2 was the change in A-VO2 Diff from rest to peak exercise (A-VO2 Diff reserve) for both HFPEF (partial correlant 0.58, standardized β coefficient 0.66; p=0.0002) and HC (partial correlant 0.61, standardized β coefficient 0.41; p=0.005) Conclusions Both reduced CO and A-VO2 Diff contribute significantly to the severe exercise intolerance in elderly HFPEF patients. The finding that A-VO2 Diff reserve is an independent predictor of peak exercise VO2 suggests that peripheral, ‘non-cardiac’ factors are important contributors to exercise intolerance in these patients. PMID:21737017

  8. Changes in ventilatory threshold with exercise training in a sedentary population: the HERITAGE Family Study.

    PubMed

    Gaskill, S E; Walker, A J; Serfass, R A; Bouchard, C; Gagnon, J; Rao, D C; Skinner, J S; Wilmore, J H; Leon, A S

    2001-11-01

    The purpose of this study was to evaluate the effect of exercise training intensity relative to the ventilatory threshold (VT) on changes in work (watts) and VO2 at the ventilatory threshold and at maximal exercise in previously sedentary participants in the HERITAGE Family Study. We hypothesized that those who exercised below their VT would improve less in VO2 at the ventilatory threshold (VO2vt) and VO2max than those who trained at an intensity greater than their VT. Supervised cycle ergometer training was performed at the 4 participating clinical centers, 3 times a week for 20 weeks. Exercise training progressed from the HR corresponding to 55% VO2max for 30 minutes to the HR associated with 75% VO2max for 50 minutes for the final 6 weeks. VT was determined at baseline and after exercise training using standardized methods. 432 sedentary white and black men (n = 224) and women (n = 208), aged 17 to 65 years, were retrospectively divided into groups based on whether exercise training was initiated below, at, or above VT. 1) Training intensity (relative to VT) accounting for about 26% of the improvement in VO2vt (R2 = 0.26, p < 0.0001). 2) The absolute intensity of training in watts (W) accounted for approximately 56% of the training effect at VT (R2 = 0.56, p < 0.0001) with post-training watts at VT (VT(watts)) being not significantly different than W during training (p > 0.70). 3) Training intensity (relative to VT) had no effect on DeltaVO2max. These data clearly show that as a result of aerobic training both the VO2 and W associated with VT respond and become similar to the absolute intensity of sustained (3 x /week for 50 min) aerobic exercise training. Higher intensities of exercise, relative to VT, result in larger gains in VO2vt but not in VO2max.

  9. Defect engineering of the oxygen-vacancy clusters formation in electron irradiated silicon by isovalent doping: An infrared perspective

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Sgourou, E. N.; Chroneos, A.

    2012-12-01

    Infrared spectroscopy was used to study the production and evolution of oxygen-vacancy (VOn for n = 1, 2, 3 and VmO for m = 1, 2, 3) clusters, in electron-irradiated Czochralski silicon (Cz-Si) samples, doped with isovalent dopants. It was determined that the production of the VO pair is enhanced in Ge-doped Si but is suppressed in Sn and Pb-doped Si. The phenomenon is discussed in terms of the competition between isovalent dopants and oxygen atoms in capturing vacancies in the course of irradiation. In the case of Ge, only transient GeV pairs form, leading finally to an increase of the VO production. Conversely, for Sn and Pb the corresponding pairs with vacancies are stable, having an opposite impact on the formation of VO pairs. Regarding V2O and V3O clusters, our measurements indicate that Ge doping enhances their formation, although Sn and Pb dopants suppress it. Similar arguments as those for the VO pair could be put forward, based on the effect of isovalent impurities on the availability of vacancies. Additionally, it was found that the conversion ratio of VO to VO2 decreases as the covalent radius of the isovalent dopant increases. These results are discussed in terms of the local strains introduced by the isovalent dopants in the Si lattice. These local strains affect the balance of the intrinsic defects created as a result of irradiation, as well as the balance between the two main reactions (VO + Oi → VO2 and VO + SiI → Oi) participating in the VO annealing, leading finally to a decrease of the VO2 production. The larger the covalent radius of the isovalent dopant (rGe < rSn < rPb), the larger the introduced strains in the lattice and then the less the VO2 formation in accordance with our experimental results. Interestingly, an opposite trend was observed for the conversion ratio of VO2 to VO3. The phenomenon is attributed to the enhanced diffusivity of oxygen impurity as a result of the presence of isovalent dopants, leading to an enhanced formation of the VO3 cluster. The results indicate that isovalent doping of Si is an effective way to control the formation of the deleterious oxygen-vacancy clustering that can affect Si-based devices.

  10. Contribution of central and peripheral factors at peak exercise in heart failure patients with progressive severity of exercise limitation.

    PubMed

    Del Torto, Alberico; Corrieri, Nicoletta; Vignati, Carlo; Gentile, Piero; Cattadori, Gaia; Paolillo, Stefania; Agostoni, Piergiuseppe

    2017-12-01

    A reduced cardiac output (CO) response during exercise is a major limiting factor in heart failure (HF). Oxygen consumption (VO 2 ) is directly proportional to CO. Peripheral mechanisms via arteriovenous oxygen difference (Δ(a-v)O 2 ) play a pivotal role in chronic HF. We hypothesized a weak correlation between peak VO 2 and peak CO with a greater Δ(a-v)O 2 variability in most severe HF. We analyzed 278 HF patients (NYHA II-III) who performed maximal cardiopulmonary exercise test with non-invasive CO measurement by inert gas rebreathing. Median peakVO 2 , CO and Δ(a-v)O 2 were 0.96 (0.78-1.28) L/min, 6.3 (5.1-8.0) L/min and 16.0 (14.2-18.0) mL/100mL respectively, with a linear relationship between VO 2 and CO: CO=5.3×VO 2 +1.13 (r 2 =0.705, p<0.001). Patients were grouped according to exercise limitation. Group 1 (101 patients) peakVO 2 <50% pred: peakVO 2 0.80 (0.67-0.94) L/min, peakCO 5.6 (4.7-6.5) L/min, peakΔ(a-v)O 2 14.8 (12.9-17.1) mL/100mL. Group 2 (89 patients) peakVO 2 ≥50-<65% pred: peakVO 2 1.02 (0.84-1.29) L/min, peakCO 6.4 (5.1-8.0) L/min, peakΔ(a-v)O 2 16.7 (15.0-18.5) mL/100mL. Group 3 (88 patients) peakVO 2 ≥65% pred: peakVO 2 1.28 (0.93-1.66) L/min, peakCO 8.0 (6.2-9.7) L/min, peakΔ(a-v)O 2 16.8 (14.6-18.3) mL/100mL. A peakVO 2 and peakCO linear relationship was observed in Group 1 (r 2 =0.381, p<0.001), Group 2 (r 2 =0.756, p<0.001) and Group 3 (r 2 =0.744, p<0.001). With worsening HF we observed a progressive reduction of peak CO and peak VO 2 . However in most compromised patients also peripheral mechanisms play a role as indicated by reduced Δ(a-v)O 2 . Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Flying high: a theoretical analysis of the factors limiting exercise performance in birds at altitude.

    PubMed

    Scott, Graham R; Milsom, William K

    2006-11-01

    The ability of some bird species to fly at extreme altitude has fascinated comparative respiratory physiologists for decades, yet there is still no consensus about what adaptations enable high altitude flight. Using a theoretical model of O(2) transport, we performed a sensitivity analysis of the factors that might limit exercise performance in birds. We found that the influence of individual physiological traits on oxygen consumption (Vo2) during exercise differed between sea level, moderate altitude, and extreme altitude. At extreme altitude, haemoglobin (Hb) O(2) affinity, total ventilation, and tissue diffusion capacity for O(2) (D(To2)) had the greatest influences on Vo2; increasing these variables should therefore have the greatest adaptive benefit for high altitude flight. There was a beneficial interaction between D(To2) and the P(50) of Hb, such that increasing D(To2) had a greater influence on Vo2 when P(50) was low. Increases in the temperature effect on P(50) could also be beneficial for high flying birds, provided that cold inspired air at extreme altitude causes a substantial difference in temperature between blood in the lungs and in the tissues. Changes in lung diffusion capacity for O(2), cardiac output, blood Hb concentration, the Bohr coefficient, or the Hill coefficient likely have less adaptive significance at high altitude. Our sensitivity analysis provides theoretical suggestions of the adaptations most likely to promote high altitude flight in birds and provides direction for future in vivo studies.

  12. Hyperoxia Reduces Oxygen Consumption in Children with Pulmonary Hypertension.

    PubMed

    Guo, Long; Bobhate, Prashant; Kumar, Shine; Vadlamudi, Karunakar; Kaddoura, Tarek; Elgendi, Mohamed; Holinski, Paula; Coe, James Y; Rutledge, Jennifer; Adatia, Ian

    2017-06-01

    High inspired oxygen concentration (FiO 2  > 0.85) is administered to test pulmonary vascular reactivity in children with pulmonary hypertension (PH). It is difficult to measure oxygen consumption (VO 2 ) if the subject is breathing a hyperoxic gas mixture so the assumption is made that baseline VO 2 does not change. We hypothesized that hyperoxia changes VO 2 . We sought to compare the VO 2 measured by a thermodilution catheter in room air and hyperoxia. A retrospective review of the hemodynamic data obtained in children with PH who underwent cardiac catheterization was conducted between 2009 and 2014. Cardiac index (CI) was measured by a thermodilution catheter in room air and hyperoxia. VO 2 was calculated using the equation CI = VO 2 /arterial-venous oxygen content difference. Data were available in 24 subjects (males = 10), with median age 8.3 years (0.8-17.6 years), weight 23.3 kg (7.5-95 kg), and body surface area 0.9 m 2 (0.4-2.0 m 2 ). In hyperoxia compared with room air, we measured decreased VO 2 (154 ± 38 to 136 ± 34 ml/min/m 2 , p = 0.007), heart rate (91 [Formula: see text] 20 to 83 [Formula: see text] 21 beats/minute, p=0.005), mean pulmonary artery pressure (41 [Formula: see text] 16 to 35 [Formula: see text] 14 mmHg, p=0.024), CI (3.6 [Formula: see text] 0.8 to 3.3 [Formula: see text] 0.9 L/min/m 2 , p = 0.03), pulmonary vascular resistance (9 [Formula: see text] 6 to 7 [Formula: see text] 3 WU m 2 , p = 0.029), increased mean aortic (61 [Formula: see text] 11 to 67 [Formula: see text] 11 mmHg, p = 0.005), pulmonary artery wedge pressures (11 [Formula: see text] 8 to 13 [Formula: see text] 9 mmHg, p = 0.006), and systemic vascular resistance (12 [Formula: see text] 6 to 20 [Formula: see text] 7 WU m 2 , p=0.001). Hyperoxia decreased VO 2 and CI and caused pulmonary vasodilation and systemic vasoconstriction in children with PH. The assumption that VO 2 remains unchanged in hyperoxia may be incorrect and, if the Fick equation is used, may lead to an overestimation of pulmonary blood flow and underestimation of PVRI.

  13. Influence of VO2 Nanoparticle Morphology on the Colorimetric Assay of H2O2 and Glucose

    PubMed Central

    Tian, Rui; Sun, Jiaheng; Qi, Yanfei; Zhang, Boyu; Guo, Shuanli; Zhao, Mingming

    2017-01-01

    Nanozyme-based colorimetric sensors have received considerable attention due to their unique properties. The size, shape, and surface chemistry of these nanozymes could dramatically influence their sensing behaviors. Herein, a comparative study of VO2 nanoparticles with different morphologies (nanofibers, nanosheets, and nanorods) was conducted and applied to the sensitive colorimetric detection of H2O2 and glucose. The peroxidase-like activities and mechanisms of VO2 nanoparticles were analyzed. Among the VO2 nanoparticles, VO2 nanofibers exhibited the best peroxidase-like activity. Finally, a comparative quantitative detections of H2O2 and glucose were done on fiber, sheet, and rod nanoparticles. Under the optimal reaction conditions, the lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for H2O2 are found to be 0.018, 0.266, and 0.41 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for H2O2 from 0.025–10, 0.488–62.5, and 0.488–15.625 mM, respectively. The lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for glucose are found to be 0.009, 0.348, and 0.437 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for glucose from 0.01–10, 0.625–15, and 0.625–10 mM, respectively. The proposed work will contribute to the nanozyme-based colorimetric assay. PMID:29068412

  14. The effect of intermittent standing or walking during head down tilt bedrest on peak O2 consumption

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Vernikos, J.

    1992-01-01

    The cardiovascular aspect of bedrest deconditioning is manifested by decreases in peak O2 uptake (VO(sub 2 peak)) during minimal exercise. The effect of intermittent standing (+G(z)) or walking (+G(z)W) during 4 days of 7 degree Head Down Tilt bedrest (HDT) on VO(sub 2 peak) was evaluated. Methods: Five protocols were performed by eight male subjects; control (C) consisting of complete bedrest, and 15 minute periods to total 2 or 4 hours daily of standing (+G(z)(exp 2) and +G(z)(exp 4) respectively) or walking at 3.0 MPH (+G(z)W2 and +G(z)W4 respectively). Subjects performed VO(sub 2 peak) tests prior to and on the final day of HDT. VO(sub 2 peak) was determined using open circuit indirect calorimetry during supine leg cycling ergometry. After a 5 minute warmup, three 2 minute incremental loads of 33 W previously determined to elicit VO(sub 2 peak) were given and the subject cycled to volitional fatigue. Results: The C protocol VO(sub 2 peak) decreased by 16 percent (2.71 plus or minus 0.16 to 2.27 plus or minus 0.14 L/min) and 11 percent in +G(z)(exp 4) (2.72 plus or minus 0.15 to 2.43 plus or minus 0.14 L/min). With +G(z)W2 VO(sub 2 peak) decreased by 9 percent (2.71 plus or minus 0.17 to 2.46 plus or minus 0.14 L/min) and with +G(z)W4, VO(sub 2 peak) decreased by 10 percent (2.71 plus or minus 0.14 to 2.43 plus or minus 0.14 L/min). VO(sub 2 peak) in all protocols decreased with HDT (P less than 0.05). The decrease in C VO(sub 2 peak) was significantly greater (P less than 0.05) than the decreases in either +G(z) or +G(z)W protocols. Conclusion: The deconditioning that occurs after only 4 days of HDT was demonstrated by decreases in VO(sub 2 peak). Intermittent +G(z) or +G(z)W attenuated, but did not prevent, the decrease in VO(sub 2 peak) with HDT.

  15. Maximal lipidic power in high competitive level triathletes and cyclists

    PubMed Central

    González‐Haro, C; Galilea, P A; González‐de‐Suso, J M; Drobnic, F; Escanero, J F

    2007-01-01

    Objective To describe the fat‐oxidation rate in triathlon and different modalities of endurance cycling. Methods 34 endurance athletes (15 male triathletes, 4 female triathletes, 11 road cyclists and 4 male mountain bikers) underwent a progressive cycloergometer test until exhaustion. Relative work intensity (VO2max), minimal lactate concentration (La−min), lactic threshold, individual lactic threshold (ILT), maximal fat‐oxidation rate (Fatmax, Fatmax zone) and minimal fat‐oxidation rate (Fatmin) were determined in each of the groups and were compared by means of one‐way analysis of variance. Results No significant differences were found for Fatmax, Fatmin or for the Fatmax zone expressed as fat oxidation rate (g/min). Intensities −20%, −10% and −5% Fatmax were significantly lower for mountain bikers with respect to road cyclists and female triathletes, expressed as % VO2max. Intensities 20%, 10% and 5% Fatmax were significantly lower for mountain bikers with respect to male triathletes and female triathletes, and for male triathletes in comparison with female triathletes, expressed as % VO2max. Lactic threshold and La−min did not show significant differences with respect to Fatmax. Lactic threshold was found at the same VO2max with respect to the higher part of the Fatmax zone, and La−min at the same VO2max with respect to the lower part of the Fatmax zone. Conclusions The VO2max of Fatmax and the Fatmax zone may explain the different endurance adaptations of the athletes according to their sporting discipline. Lactic threshold and La−min were found at different relative work intensities with respect to those of Fatmax even though they belonged to the Fatmax zone. PMID:17062656

  16. Metal-semiconductor phase transition of order arrays of VO2 nanocrystals

    NASA Astrophysics Data System (ADS)

    Lopez, Rene; Suh, Jae; Feldman, Leonard; Haglund, Richard

    2004-03-01

    The study of solid-state phase transitions at nanometer length scales provides new insights into the effects of material size on the mechanisms of structural transformations. Such research also opens the door to new applications, either because materials properties are modified as a function of particle size, or because the nanoparticles interact with a surrounding matrix material, or with each other. In this paper, we describe the formation of vanadium dioxide nanoparticles in silicon substrates by pulsed laser deposition of ion beam lithographically selected sites and thermal processing. We observe the collective behavior of 50 nm diameter VO2 oblate nanoparticles, 10 nm high, and ordered in square arrays with arbitrary lattice constant. The metal-semiconductor-transition of the VO2 precipitates shows different features in each lattice spacing substrate. The materials are characterized by electron microscopy, x-ray diffraction, Rutherford backscattering. The features of the phase transition are studied via infrared optical spectroscopy. Of particular interest are the enhanced scattering and the surface plasmon resonance when the particles reach the metallic state. This resonance amplifies the optical contrast in the range of near-infrared optical communication wavelengths and it is altered by the particle-particle coupling as in the case of noble metals. In addition the VO2 nanoparticles exhibit sharp transitions with up to 50 K of hysteresis, one of the largest values ever reported for this transition. The optical properties of the VO2 nanoarrays are correlated with the size of the precipitates and their inter-particle distance. Nonlinear and ultra fast optical measurements have shown that the transition is the fastest known solid-solid transformation. The VO2 nanoparticles show the same bulk property, transforming in times shorter than 150 fs. This makes them remarkable candidates for ultrafast optical and electronic switching applications.

  17. Selection of patients for heart transplantation in the current era of heart failure therapy.

    PubMed

    Butler, Javed; Khadim, Ghazanfar; Paul, Kimberly M; Davis, Stacy F; Kronenberg, Marvin W; Chomsky, Don B; Pierson, Richard N; Wilson, John R

    2004-03-03

    We sought to assess the relationship between survival, peak exercise oxygen consumption (VO(2)), and heart failure survival score (HFSS) in the current era of heart failure (HF) therapy. Based on predicted survival, HF patients with peak VO(2) <14 ml/min/kg or medium- to high-risk HFSS are currently considered eligible for heart transplantation. However, these criteria were developed before the widespread use of beta-blockers, spironolactone, and defibrillators-interventions known to improve the survival of HF patients. Peak VO(2) and HFSS were assessed in 320 patients followed from 1994 to 1997 (past era) and in 187 patients followed from 1999 to 2001 (current era). Outcomes were compared between these two groups of patients and those who underwent heart transplantation from 1993 to 2000. Survival in the past era was 78% at one year and 67% at two years, as compared with 88% and 79%, respectively, in the current era (both p < 0.01). One-year event-free survival (without urgent transplantation or left ventricular assist device) was improved in the current era, regardless of initial peak VO(2): 64% vs. 48% for peak VO(2) <10 ml/min/kg (p = 0.09), 81% vs. 70% for 10 to 14 ml/min/kg (p = 0.05), and 93% vs. 82% for >14 ml/min/kg (p = 0.04). Of the patients with peak VO(2) of 10 to 14 ml/min/kg, 55% had low-risk HFSS and exhibited 88% one-year event-free survival. One-year survival after transplantation was 88%, which is similar to the 85% rate reported by the United Network for Organ Sharing for 1999 to 2000. Survival for HF patients in the current era has improved significantly, necessitating re-evaluation of the listing criteria for heart transplantation.

  18. Voltage switching of a VO{sub 2} memory metasurface using ionic gel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldflam, M. D.; Liu, M. K.; Chapler, B. C.

    2014-07-28

    We demonstrate an electrolyte-based voltage tunable vanadium dioxide (VO{sub 2}) memory metasurface. Large spatial scale, low voltage, non-volatile switching of terahertz (THz) metasurface resonances is achieved through voltage application using an ionic gel to drive the insulator-to-metal transition in an underlying VO{sub 2} layer. Positive and negative voltage application can selectively tune the metasurface resonance into the “off” or “on” state by pushing the VO{sub 2} into a more conductive or insulating regime respectively. Compared to graphene based control devices, the relatively long saturation time of resonance modification in VO{sub 2} based devices suggests that this voltage-induced switching originates primarilymore » from electrochemical effects related to oxygen migration across the electrolyte–VO{sub 2} interface.« less

  19. A comparative analysis of physiological responses at submaximal workloads during different laboratory simulations of field cycling.

    PubMed

    Kenny, G P; Reardon, F D; Marion, A; Thoden, J S

    1995-01-01

    The purpose of this study was to evaluate the relationships between heart rate (fc), oxygen consumption (VO2), peak force and average force developed at the crank in response to submaximal exercise employing a racing bicycle which was attached to an ergometer (RE), ridden on a treadmill (TC) and ridden on a 400-m track (FC). Eight male trained competitive cyclists rode at three pre-determined work intensities set at a proportion of their maximal oxygen consumption (VO2max): (1) below lactate threshold [work load that produces a VO2 which is 10% less than the lactate threshold VO2 (sub-LT)], (2) lactate threshold VO2 (LT), and (3) above lactate threshold [workload that produces a VO2 which is 10% greater than lactate threshold VO2 (supra-LT)], and equated across exercise modes on the basis of fc. Voltage signals from the crank arm were recorded as FM signals for subsequent representation of peak and average force. Open circuit VO2 measurements were done in the field by Douglas bag gas collection and in the laboratory by automated gas collection and analysis. fc was recorded with a telemeter (Polar Electro Sport Tester, PE3000). Significant differences (P < 0.05) were observed: (1) in VO2 between FC and both laboratory conditions at sub-LT intensity and LT intensities, (2) in peak force between FC and TC at sub-LT intensity, (3) in average force between FC and RE at sub-LT. No significant differences were demonstrated at supra-LT intensity for VO2. Similarly no significant differences were observed in peak and average force for either LT or supra-LT intensities. These data indicate that equating work intensities on the basis of fc measured in laboratory conditions would overestimate the VO2 which would be generated in the field and conversely, that using fc measured in the laboratory to establish field work intensity would underestimate mechanical workload experienced in the field.

  20. The effects of recovery duration during high-intensity interval exercise on time spent at high rates of oxygen consumption, oxygen kinetics and blood lactate.

    PubMed

    Smilios, Ilias; Myrkos, Aristides; Zafeiridis, Andreas; Toubekis, Argyris; Spassis, Apostolos; Tokmakidis, Savas P

    2017-03-13

    The recovery duration and the work to recovery ratio are important aspects to consider when designing a high-intensity aerobic interval exercise (HIIE). This study examined the effects of recovery duration on total exercise time performed above 80, 90 and 95% of maximum oxygen consumption (VO2max) and heart rate (HRmax) during a single-bout HIIE. We also evaluated the effects on VO2 and HR kinetics, blood lactate concentration and rating of perceived exertion (RPE). Eleven moderately trained males (22.1±1 yrs.) executed, on three separate sessions, 4×4-min runs at 90% of maximal aerobic velocity (MAV) with 2-min, 3-min and 4-min of active recovery. Recovery duration did not affect the percentage of VO2max attained and the total exercise time above 80, 90 and 95% of VO2max. Exercise time above 80 and 90% of HRmax was longer with 2 and 3 min (p<0.05) as compared with the 4-min recovery. Oxygen uptake and HR amplitude were lower, mean response time slower (p<0.05), and blood lactate and RPE higher with 2-min compared to 4-min recovery (p<0.05). In conclusion, aerobic metabolism attains its upper functional limits with either 2, or 3 or 4 min of recovery during the 4×4 min HIIE; thus, all rest durations could be used for the enhancement of aerobic capacity in sports, fitness, and clinical settings. The short (2 min) compared to longer (4 min) recovery, however, evokes greater cardiovascular and metabolic stress, and activates to a greater extent anaerobic glycolysis, and hence, could be used by athletes to induce greater overall physiological challenge.

  1. The Effects of a Duathlon Simulation on Ventilatory Threshold and Running Economy

    PubMed Central

    Berry, Nathaniel T.; Wideman, Laurie; Shields, Edgar W.; Battaglini, Claudio L.

    2016-01-01

    Multisport events continue to grow in popularity among recreational, amateur, and professional athletes around the world. This study aimed to determine the compounding effects of the initial run and cycling legs of an International Triathlon Union (ITU) Duathlon simulation on maximal oxygen uptake (VO2max), ventilatory threshold (VT) and running economy (RE) within a thermoneutral, laboratory controlled setting. Seven highly trained multisport athletes completed three trials; Trial-1 consisted of a speed only VO2max treadmill protocol (SOVO2max) to determine VO2max, VT, and RE during a single-bout run; Trial-2 consisted of a 10 km run at 98% of VT followed by an incremental VO2max test on the cycle ergometer; Trial-3 consisted of a 10 km run and 30 km cycling bout at 98% of VT followed by a speed only treadmill test to determine the compounding effects of the initial legs of a duathlon on VO2max, VT, and RE. A repeated measures ANOVA was performed to determine differences between variables across trials. No difference in VO2max, VT (%VO2max), maximal HR, or maximal RPE was observed across trials. Oxygen consumption at VT was significantly lower during Trial-3 compared to Trial-1 (p = 0.01). This decrease was coupled with a significant reduction in running speed at VT (p = 0.015). A significant interaction between trial and running speed indicate that RE was significantly altered during Trial-3 compared to Trial-1 (p < 0.001). The first two legs of a laboratory based duathlon simulation negatively impact VT and RE. Our findings may provide a useful method to evaluate multisport athletes since a single-bout incremental treadmill test fails to reveal important alterations in physiological thresholds. Key points Decrease in relative oxygen uptake at VT (ml·kg-1·min-1) during the final leg of a duathlon simulation, compared to a single-bout maximal run. We observed a decrease in running speed at VT during the final leg of a duathlon simulation; resulting in an increase of more than 2 minutes to complete a 5 km run. During our study, highly trained athletes were unable to complete the final 5 km run at the same intensity that they completed the initial 10 km run (in a laboratory setting). A better understanding, and determination, of training loads during multisport training may help to better periodize training programs; additional research is required. PMID:27274661

  2. VO2 Kinetics and Metabolic Contributions Whilst Swimming at 95, 100, and 105% of the Velocity at VO2 max

    PubMed Central

    Sousa, Ana C.; Vilas-Boas, João P.; Fernandes, Ricardo J.

    2014-01-01

    A bioenergetical analysis of swimming at intensities near competitive distances is inexistent. It was aimed to compare the transient VO2 kinetics responses and metabolic contributions whilst swimming at different velocities around VO2max⁡. 12 trained male swimmers performed (i) an incremental protocol to determine the velocity at VO2max⁡ (vVO2max⁡) and (ii) three square wave exercises from rest to 95, 100, and 105% of vVO2max⁡. VO2 was directly measured using a telemetric portable gas analyser and its kinetics analysed through a double-exponential model. Metabolic contributions were assessed through the sum of three energy components. No differences were observed in the fast component response (τ 1—15, 18, and 16 s, A 1—36, 34, and 37 mL · kg−1 · min⁡−1, and Gain—32, 29, and 30 mL · min⁡−1 at 95, 100, and 105% of the vVO2max⁡, resp.) but A2 was higher in 95 and 100% compared to 105% intensity (480.76 ± 247.01, 452.18 ± 217.04, and 147.04 ± 60.40 mL · min⁡−1, resp.). The aerobic energy contribution increased with the time sustained (83 ± 5, 74 ± 6, and 59 ± 7% for 95, 100, and 105%, resp.). The adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery and diffusion to the exercising muscles did not change with changing intensity, with the exception of VO2 slow component kinetics metabolic profiles. PMID:25045690

  3. Effects of high-intensity interval training on physical capacities and substrate oxidation rate in obese adolescents.

    PubMed

    Lazzer, S; Tringali, G; Caccavale, M; De Micheli, R; Abbruzzese, L; Sartorio, A

    2017-02-01

    To investigate the effects of a 3-week weight-management program entailing moderate energy restriction, nutritional education, psychological counseling and three different exercise training (a: low intensity, LI: 40 % V'O 2 max; b: high intensity, HI: 70 % V'O 2 max; c: high-intensity interval training, HIIT), on body composition, energy expenditure and fat oxidation rate in obese adolescents. Thirty obese adolescents (age: 15-17 years, BMI: 37.5 kg m -2 ) participated in this study. Before starting (week 0, W0) and at the end of the weight-management program (week 3, W3), body composition was assessed by an impedancemeter; basal metabolic rate (BMR), energy expenditure and substrate oxidation rate were measured during exercise and post-exercise recovery by indirect calorimetry. At W3, body mass (BM) and fat mass (FM) decreased significantly in all groups, the decreases being significantly greater in the LI than in the HI and HIIT subgroups (BM: -8.4 ± 1.5 vs -6.3 ± 1.9 vs -4.9 ± 1.3 kg and FM: -4.2 ± 1.9 vs -2.8 ± 1.2 vs -2.3 ± 1.4 kg, p < 0.05, respectively). V'O 2 peak, expressed in relative values, changed significantly only in the HI and HIIT groups by 0.009 ± 0.005 and 0.007 ± 0.004 L kg FFM -1  min -1 (p < 0.05). Furthermore, the HI and HIIT subgroups exhibited a greater absolute rate of fat oxidation between 50 and 70 % V'O 2 peak at W3. No significant changes were observed at W3 in BMR, energy expenditure during exercise and post-exercise recovery. A 3-week weight-management program induced a greater decrease in BM and FM in the LI than in the HI and HIIT subgroups, and greater increase in V'O 2 peak and fat oxidation rate in the HI and HIIT than in the LI subgroup.

  4. The preparation of Ag-BiVO4 metal composite oxides and its application in efficient photocatalytic oxidative thiophene

    NASA Astrophysics Data System (ADS)

    Gao, Xiao-Ming; Fu, Feng; Zhang, Li-Ping; Li, Wen-Hong

    2013-06-01

    A series of Ag-BiVO4 photocatalysts was synthesized by the hydrothemal synthesis method for different pH values. A strong correlation was found among the prepared processing, structure and property of the samples. With increasing pH value from 5 to 9, the crystallinity increases and the as-prepared Ag-BiVO4 sample gradually disappeared from the nanostructures. The light absorption became higher in the UV and visible range, accompanied by a bathochromic shift of the absorption edge. The competitive relations between crystallinity and surface area affecting photocatalytic activity were also discussed. Photocatalytic desulfurization on the as-prepared Ag-BiVO4 samples using thiophene dissolved in n-octane as a model organosulfur compound was performed. It showed that the photocatalytic desulfurization on the as-prepared Ag-BiVO4 sample at pH=7 can be up to 95%, which existed as various size particles and had significant high surface area of 13.768 m2 g-1.

  5. Estimation of maximal oxygen uptake via submaximal exercise testing in sports, clinical, and home settings.

    PubMed

    Sartor, Francesco; Vernillo, Gianluca; de Morree, Helma M; Bonomi, Alberto G; La Torre, Antonio; Kubis, Hans-Peter; Veicsteinas, Arsenio

    2013-09-01

    Assessment of the functional capacity of the cardiovascular system is essential in sports medicine. For athletes, the maximal oxygen uptake [Formula: see text] provides valuable information about their aerobic power. In the clinical setting, the (VO(2max)) provides important diagnostic and prognostic information in several clinical populations, such as patients with coronary artery disease or heart failure. Likewise, VO(2max) assessment can be very important to evaluate fitness in asymptomatic adults. Although direct determination of [VO(2max) is the most accurate method, it requires a maximal level of exertion, which brings a higher risk of adverse events in individuals with an intermediate to high risk of cardiovascular problems. Estimation of VO(2max) during submaximal exercise testing can offer a precious alternative. Over the past decades, many protocols have been developed for this purpose. The present review gives an overview of these submaximal protocols and aims to facilitate appropriate test selection in sports, clinical, and home settings. Several factors must be considered when selecting a protocol: (i) The population being tested and its specific needs in terms of safety, supervision, and accuracy and repeatability of the VO(2max) estimation. (ii) The parameters upon which the prediction is based (e.g. heart rate, power output, rating of perceived exertion [RPE]), as well as the need for additional clinically relevant parameters (e.g. blood pressure, ECG). (iii) The appropriate test modality that should meet the above-mentioned requirements should also be in line with the functional mobility of the target population, and depends on the available equipment. In the sports setting, high repeatability is crucial to track training-induced seasonal changes. In the clinical setting, special attention must be paid to the test modality, because multiple physiological parameters often need to be measured during test execution. When estimating VO(2max), one has to be aware of the effects of medication on heart rate-based submaximal protocols. In the home setting, the submaximal protocols need to be accessible to users with a broad range of characteristics in terms of age, equipment, time available, and an absence of supervision. In this setting, the smart use of sensors such as accelerometers and heart rate monitors will result in protocol-free VO(2max) assessments. In conclusion, the need for a low-risk, low-cost, low-supervision, and objective evaluation of VO(2max) has brought about the development and the validation of a large number of submaximal exercise tests. It is of paramount importance to use these tests in the right context (sports, clinical, home), to consider the population in which they were developed, and to be aware of their limitations.

  6. O2 uptake kinetics during exercise at peak O2 uptake.

    PubMed

    Scheuermann, Barry W; Barstow, Thomas J

    2003-11-01

    Compared with moderate- and heavy-intensity exercise, the adjustment of O2 uptake (VO2) to exercise intensities that elicit peak VO2 has received relatively little attention. This study examined the VO2 response of 21 young, healthy subjects (25 +/- 6 yr; mean +/- SD) during cycle ergometer exercise to step transitions in work rate (WR) corresponding to 90, 100, and 110% of the peak WR achieved during a preliminary ramp protocol (15-30 W/min). Gas exchange was measured breath by breath and interpolated to 1-s values. VO2 kinetics were determined by use of a two- or three-component exponential model to isolate the time constant (tau2) as representative of VO2 kinetics and the amplitude (Amp) of the primary fast component independent of the appearance of any VO2 slow component. No difference in VO2 kinetics was observed between WRs (tau90 = 24.7 +/- 9.0; tau100 = 22.8 +/- 6.7; tau110 = 21.5 +/- 9.2 s, where subscripts denote percent of peak WR; P > 0.05); nor in a subgroup of eight subjects was tau2 different from the value for moderate-intensity ( 0.05). As expected, the Amp increased with increasing WRs (Amp90 = 2,089 +/- 548; Amp100 = 2,165 +/- 517; Amp110 = 2,225 +/- 559 ml/min; Amp90 vs. Amp110, P < 0.05). However, the gain (G) of the VO2 response (deltaVO2/deltaWR) decreased with increasing WRs (G90 = 8.5 +/- 0.6; G100 = 7.9 +/- 0.6; G110 = 7.3 +/- 0.6 ml.min-1.W-1; P < 0.05). The Amp of the primary component approximated 85, 88, and 89% of peak Vo2 during 90, 100, and 110% WR transitions, respectively. The results of the present study demonstrate that, compared with moderate- and heavy-intensity exercise, the gain of the Vo2 response (as deltaVO2/DeltaWR) is reduced for exercise transitions in the severe-intensity domain, but the approach to this gain is well described by a common time constant that is invariant across work intensities. The lower deltaVO2/deltaWR may be due to an insufficient adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery to the exercising muscles or due to recruitment of motor units with lower oxidative capacity, after the onset of exercise in the severe-intensity domain.

  7. Vanadium dioxide-based materials for potential thermal switching applications

    NASA Astrophysics Data System (ADS)

    Jeong, Minyoung

    One of the materials able to exhibit a transition from insulators to metals (IMT materials) is vanadium dioxide (VO2). Through IMT, VO2 shows a drop of resistivity of five orders of magnitude at a picosecond timescale. In this work, the feasibility of using VO2 as an efficient thermal switching device is discussed. Several synthesis methods (sol-gel, hot press and spark plasma sintering) were attempted to obtain VO2 sample in pellet form. From the X-ray diffraction results, it was found that spark plasma sintering (SPS) yielded the highest phase purity. Several sintering parameters such as temperature or sintering time were tested to determine the optimal sintering conditions. For better thermal switching behavior, high-energy ball milling was used to reduce lattice thermal conductivity (klat.) in the insulator phase. Ball-milling time was varied from 30 minutes to 2 hours. It was found that with increasing milling time, the k lat. was reduced. Thus, it was demonstrated that thermal switching behavior was most efficient with 2 hour-milling. To improve electronic thermal conductivity ( kelec.) in the metallic state, nano-sized copper particles were added to the VO2 system with a subtle amount variation ranging from 3at % to 5 at%. Results show that a composite with 5 at% Cu (copper) addition exhibited the largest increase in thermal conductivity ( k) in the metallic state. In addition to this, a basic mechanism behind IMT and some of the exemplary IMT-based applications were introduced.

  8. Functional genomics reveals increases in cholesterol biosynthetic genes and highly unsaturated fatty acid biosynthesis after dietary substitution of fish oil with vegetable oils in Atlantic salmon (Salmo salar)

    PubMed Central

    Leaver, Michael J; Villeneuve, Laure AN; Obach, Alex; Jensen, Linda; Bron, James E; Tocher, Douglas R; Taggart, John B

    2008-01-01

    Background There is an increasing drive to replace fish oil (FO) in finfish aquaculture diets with vegetable oils (VO), driven by the short supply of FO derived from wild fish stocks. However, little is known of the consequences for fish health after such substitution. The effect of dietary VO on hepatic gene expression, lipid composition and growth was determined in Atlantic salmon (Salmo salar), using a combination of cDNA microarray, lipid, and biochemical analysis. FO was replaced with VO, added to diets as rapeseed (RO), soybean (SO) or linseed (LO) oils. Results Dietary VO had no major effect on growth of the fish, but increased the whole fish protein contents and tended to decrease whole fish lipid content, thus increasing the protein:lipid ratio. Expression levels of genes of the highly unsaturated fatty acid (HUFA) and cholesterol biosynthetic pathways were increased in all vegetable oil diets as was SREBP2, a master transcriptional regulator of these pathways. Other genes whose expression was increased by feeding VO included those of NADPH generation, lipid transport, peroxisomal fatty acid oxidation, a marker of intracellular lipid accumulation, and protein and RNA processing. Consistent with these results, HUFA biosynthesis, hepatic β-oxidation activity and enzymic NADPH production were changed by VO, and there was a trend for increased hepatic lipid in LO and SO diets. Tissue cholesterol levels in VO fed fish were the same as animals fed FO, whereas fatty acid composition of the tissues largely reflected those of the diets and was marked by enrichment of 18 carbon fatty acids and reductions in 20 and 22 carbon HUFA. Conclusion This combined gene expression, compositional and metabolic study demonstrates that major lipid metabolic effects occur after replacing FO with VO in salmon diets. These effects are most likely mediated by SREBP2, which responds to reductions in dietary cholesterol. These changes are sufficient to maintain whole body cholesterol levels but not HUFA levels. PMID:18577222

  9. The effect of breathing an ambient low‐density, hyperoxic gas on the perceived effort of breathing and maximal performance of exercise in well‐trained athletes

    PubMed Central

    Ansley, L; Petersen, D; Thomas, A; Gibson, A St Clair; Robson‐Ansley, P; Noakes, T D

    2007-01-01

    Background The role of the perception of breathing effort in the regulation of performance of maximal exercise remains unclear. Aims To determine whether the perceived effort of ventilation is altered through substituting a less dense gas for normal ambient air and whether this substitution affects performance of maximal incremental exercise in trained athletes. Methods Eight highly trained cyclists (mean SD) maximal oxygen consumption (VO2max) = 69.9 (7.9) (mlO2/kg/min) performed two randomised maximal tests in a hyperbaric chamber breathing ambient air composed of either 35% O2/65% N2 (nitrox) or 35% O2/65% He (heliox). A ramp protocol was used in which power output was incremented at 0.5 W/s. The trials were separated by at least 48 h. The perceived effort of breathing was obtained via Borg Category Ratio Scales at 3‐min intervals and at fatigue. Oxygen consumption (VO2) and minute ventilation (VE) were monitored continuously. Results Breathing heliox did not change the sensation of dyspnoea: there were no differences between trials for the Borg scales at any time point. Exercise performance was not different between the nitrox and heliox trials (peak power output = 451 (58) and 453 (56) W), nor was VO2max (4.96 (0.61) and 4.88 (0.65) l/min) or maximal VE (157 (24) and 163 (22) l/min). Between‐trial variability in peak power output was less than either VO2max or maximal VE. Conclusion Breathing a less dense gas does not improve maximal performance of exercise or reduce the perception of breathing effort in highly trained athletes, although an attenuated submaximal tidal volume and VE with a concomitant reduction in VO2 suggests an improved gas exchange and reduced O2 cost of ventilation when breathing heliox. PMID:17062658

  10. C=C bond cleavage on neutral VO3(V2O5)n clusters.

    PubMed

    Dong, Feng; Heinbuch, Scott; Xie, Yan; Bernstein, Elliot R; Rocca, Jorge J; Wang, Zhe-Chen; Ding, Xun-Lei; He, Sheng-Gui

    2009-01-28

    The reactions of neutral vanadium oxide clusters with alkenes (ethylene, propylene, 1-butene, and 1,3-butadiene) are investigated by experiments and density function theory (DFT) calculations. Single photon ionization through extreme ultraviolet radiation (EUV, 46.9 nm, 26.5 eV) is used to detect neutral cluster distributions and reaction products. In the experiments, we observe products (V(2)O(5))(n)VO(2)CH(2), (V(2)O(5))(n)VO(2)C(2)H(4), (V(2)O(5))(n)VO(2)C(3)H(4), and (V(2)O(5))(n)VO(2)C(3)H(6), for neural V(m)O(n) clusters in reactions with C(2)H(4), C(3)H(6), C(4)H(6), and C(4)H(8), respectively. The observation of these products indicates that the C=C bonds of alkenes can be broken on neutral oxygen rich vanadium oxide clusters with the general structure VO(3)(V(2)O(5))(n=0,1,2...). DFT calculations demonstrate that the reaction VO(3) + C(3)H(6) --> VO(2)C(2)H(4) + H(2)CO is thermodynamically favorable and overall barrierless at room temperature. They also provide a mechanistic explanation for the general reaction in which the C=C double bond of alkenes is broken on VO(3)(V(2)O(5))(n=0,1,2...) clusters. A catalytic cycle for alkene oxidation on vanadium oxide is suggested based on our experimental and theoretical investigations. The reactions of V(m)O(n) with C(6)H(6) and C(2)F(4) are also investigated by experiments. The products VO(2)(V(2)O(5))(n)C(6)H(4) are observed for dehydration reactions between V(m)O(n) clusters and C(6)H(6). No product is detected for V(m)O(n) clusters reacting with C(2)F(4). The mechanisms of the reactions between VO(3) and C(2)F(4)/C(6)H(6) are also investigated by calculations at the B3LYP/TZVP level.

  11. Effect of BMI, Body Fat Percentage and Fat Free Mass on Maximal Oxygen Consumption in Healthy Young Adults.

    PubMed

    Mondal, Himel; Mishra, Snigdha Prava

    2017-06-01

    Maximal oxygen consumption (VO 2max ) is an important measure of cardiorespiratory capacity of an individual at a given degree of fitness and oxygen availability. Risk of cardiovascular diseases increases with increasing degree of obesity and a low level of VO 2max has been established as an independent risk factor for cardiovascular mortality. To determine VO 2max in young adults and to find its correlation with Body Mass Index (BMI), Body Fat% and Fat Free Mass (FFM). Fifty four (male=30, female=24) healthy young adults of age group18-25 years after screening by Physical Activity Readiness Questionnaire (PAR-Q) participated in the study. Height was measured by stadiometer. Weight was measured by digital weighing scale with 0.1 kg sensitivity. Body fat% was measured by Bioelectrical Impedance Analysis (BIA) method. FFM was calculated by subtracting fat mass from the body weight. VO 2max (mL.kg -1 .min -1 ) was obtained by Submaximal Exercise Test (SET) by first two stages of Bruce Protocol with the basis of linear relationship between Heart Rate (HR) and oxygen consumption (VO 2 ). Data were analysed statistically in GraphPad Prism software version 6.01 for windows. VO 2max (mL.kg -1 .min -1 ) of male (43.25±7.25) was significantly (p<0.001) higher than female (31.65±2.10). BMI showed weak negative correlation (r= -0.3232, p=0.0171) with VO 2max but Body Fat% showed strong negative correlation (r= -0.7505, p<0.001) with VO 2max . FFM positively correlated (r=0.3727, p=0.0055) with VO 2max . Increased body fat is associated with decreased level of VO 2max in young adults. Obesity in terms of Fat% is a better parameter than BMI for prediction of low VO 2max .

  12. Factors affecting oxygen consumption in wild-caught yellow-bellied marmots (Marmota flaviventris).

    PubMed

    Armitage, K B; Salsbury, C M

    1992-12-01

    1. All age groups gained mass during the active season, but mass-gain of adult females was delayed during lactation. 2. The relationship of body mass to metabolic rate varied widely; when the relationship was significant, R2 varied from 10.3 to 72.6%. Body mass affects VO2 more during lactation than at any other period. 3. Mean VO2 of adult males was higher in June than that of adult, non-lactating females. 4. VO2 of reproductive females was significantly higher during lactation than during gestation or postlactation because specific VO2 varied. Specific VO2 of non-reproductive females declined over the active season. 5. Specific VO2 of all age groups declined between the premolt and postmolt periods. The reduced maintenance costs can contribute 20-46% to daily growth. 6. Observed VO2 was lower than the value predicted from intraspecific or interspecific Bm:M regressions. 7. VO2 of wild-caught marmots was lower than that of marmots maintained in the laboratory, probably because of dietary differences. 8. Because basal metabolism is a stage on a food-deprivation curve, we suggest that basal metabolic rate is not an appropriate measure of the metabolic activity of free-ranging animals.

  13. Effects of low-volume high-intensity interval training (HIT) on fitness in adults: a meta-analysis of controlled and non-controlled trials.

    PubMed

    Weston, Matthew; Taylor, Kathryn L; Batterham, Alan M; Hopkins, Will G

    2014-07-01

    Low-volume high-intensity interval training (HIT) appears to be an efficient and practical way to develop physical fitness. Our objective was to estimate meta-analysed mean effects of HIT on aerobic power (maximum oxygen consumption [VO(2max)] in an incremental test) and sprint fitness (peak and mean power in a 30-s Wingate test). Five databases (PubMed, MEDLINE, Scopus, BIOSIS and Web of Science) were searched for original research articles published up to January 2014. Search terms included 'high intensity', 'HIT', 'sprint', 'fitness' and 'VO(2max)'. Inclusion criteria were fitness assessed pre- and post-training; training period ≥2 weeks; repetition duration 30-60 s; work/rest ratio <1.0; exercise intensity described as maximal or near maximal; adult subjects aged >18 years. The final data set consisted of 55 estimates from 32 trials for VO(2max), 23 estimates from 16 trials for peak sprint power, and 19 estimates from 12 trials for mean sprint power. Effects on fitness were analysed as percentages via log transformation. Standard errors calculated from exact p values (where reported) or imputed from errors of measurement provided appropriate weightings. Fixed effects in the meta-regression model included type of study (controlled, uncontrolled), subject characteristics (sex, training status, baseline fitness) and training parameters (number of training sessions, repetition duration, work/rest ratio). Probabilistic magnitude-based inferences for meta-analysed effects were based on standardized thresholds for small, moderate and large changes (0.2, 0.6 and 1.2, respectively) derived from between-subject standard deviations (SDs) for baseline fitness. A mean low-volume HIT protocol (13 training sessions, 0.16 work/rest ratio) in a controlled trial produced a likely moderate improvement in the VO(2max) of active non-athletic males (6.2 %; 90 % confidence limits ±3.1 %), when compared with control. There were possibly moderate improvements in the VO(2max) of sedentary males (10.0 %; ±5.1 %) and active non-athletic females (3.6 %; ±4.3 %) and a likely small increase for sedentary females (7.3 %; ±4.8 %). The effect on the VO(2max) of athletic males was unclear (2.7 %; ±4.6 %). A possibly moderate additional increase was likely for subjects with a 10 mL·kg(-1)·min(-1) lower baseline VO(2max) (3.8 %; ±2.5 %), whereas the modifying effects of sex and difference in exercise dose were unclear. The comparison of HIT with traditional endurance training was unclear (-1.6 %; ±4.3 %). Unexplained variation between studies was 2.0 % (SD). Meta-analysed effects of HIT on Wingate peak and mean power were unclear. Low-volume HIT produces moderate improvements in the aerobic power of active non-athletic and sedentary subjects. More studies are needed to resolve the unclear modifying effects of sex and HIT dose on aerobic power and the unclear effects on sprint fitness.

  14. Evaluation of Analytical Modeling Functions for the Phonation Onset Process.

    PubMed

    Petermann, Simon; Kniesburges, Stefan; Ziethe, Anke; Schützenberger, Anne; Döllinger, Michael

    2016-01-01

    The human voice originates from oscillations of the vocal folds in the larynx. The duration of the voice onset (VO), called the voice onset time (VOT), is currently under investigation as a clinical indicator for correct laryngeal functionality. Different analytical approaches for computing the VOT based on endoscopic imaging were compared to determine the most reliable method to quantify automatically the transient vocal fold oscillations during VO. Transnasal endoscopic imaging in combination with a high-speed camera (8000 fps) was applied to visualize the phonation onset process. Two different definitions of VO interval were investigated. Six analytical functions were tested that approximate the envelope of the filtered or unfiltered glottal area waveform (GAW) during phonation onset. A total of 126 recordings from nine healthy males and 210 recordings from 15 healthy females were evaluated. Three criteria were analyzed to determine the most appropriate computation approach: (1) reliability of the fit function for a correct approximation of VO; (2) consistency represented by the standard deviation of VOT; and (3) accuracy of the approximation of VO. The results suggest the computation of VOT by a fourth-order polynomial approximation in the interval between 32.2 and 67.8% of the saturation amplitude of the filtered GAW.

  15. Oxygen uptake kinetics and exercise capacity in children with cystic fibrosis.

    PubMed

    Fielding, Jeremy; Brantley, Lucy; Seigler, Nichole; McKie, Katie T; Davison, Gareth W; Harris, Ryan A

    2015-07-01

    Exercise capacity, an objective measure of exercise intolerance, is known to predict quality of life and mortality in cystic fibrosis (CF). The mechanisms for exercise intolerance in patients with cystic fibrosis (CF), however, have yet to be fully elucidated. Accordingly, this study sought to investigate oxygen uptake kinetics and the impact of fat-free mass (FFM) on exercise capacity in young patients with CF. 16 young patients with CF (age 13 ± 4 years; 10 female) and 15 matched controls (age 14 ± 3 years; nine female) participated. Pulmonary function and a maximal exercise test on a cycle ergometer using the Godfrey protocol were performed. Exercise capacity (VO2 peak), VO2 response time (VO2 RT), and functional VO2 gain (ΔVO2 /ΔWR) were all determined. Lung function was the only demographic parameter significantly lower (P < 0.05) in CF compared to controls. Exercise capacity was lower in CF (P < 0.014) only when VO2 peak was normalized for FFM (43.5 ± 7.7 vs. 50.6 ± 7.4 ml/kg-FFM/min) or expressed as % predicted (70.1 ± 14.3 vs. 85.4 ± 16.0%). The VO2 RT was slower (36.1 ± 15.1 vs. 25.0 ± 12.4 sec; P = 0.03) and the ΔVO2 /ΔWR slope was lower (8.4 ± 3 ml/min/watt vs. 10.1 ± 1.4 ml/min/watt; P = 0.02) in patients compared to controls, respectively. In conclusion, a delayed VO2 response time coupled with the lower functional VO2 gain (ΔVO2 /ΔWR) suggest that young patients with CF have impairment in oxygen transport and oxygen utilization by the muscles. These data in addition to differences in VO2 peak normalized for FFM provide some insight that muscle mass and muscle metabolism contribute to exercise intolerance in CF. © 2015 Wiley Periodicals, Inc.

  16. Voltage-Controlled Switching and Thermal Effects in VO2 Nano-Gap Junctions

    DTIC Science & Technology

    2014-06-09

    Voltage-controlled switching and thermal effects in VO2 nano-gap junctions Arash Joushaghani,1 Junho Jeong,1 Suzanne Paradis,2 David Alain,2 J...2014) Voltage-controlled switching in lateral VO2 nano-gap junctions with different gap lengths and thermal properties was investigated. The effect of...indicate that the VO2 phase transition was likely initiated electroni- cally, which was sometimes followed by a secondary thermally-induced transition

  17. An improved scan laser with a VO2 programmable mirror

    NASA Astrophysics Data System (ADS)

    Chivian, J. S.; Scott, M. W.; Case, W. E.; Krasutsky, N. J.

    1985-04-01

    A 10.6-microns scan laser has been constructed and operated with an off-axis cathode ray tube, high reflectance multilayer thin-film structures, and a tapered plasma discharge tube. Equations are given for the switching time of a high-reflectance spot on the VO2 and for the relation of scan laser output power to cavity geometry, cavity losses, and the gain of the active CO2 medium. A scan capability of 2100 easily resolvable directions was demonstrated, and sequential and randomly addressed spot rates of 100,000/sec were achieved. The equations relating output power and cavity mode size were experimentally verified using a nonscanned beam.

  18. Structure, hydrolysis, and diffusion of aqueous vanadium ions from Car-Parrinello molecular dynamics

    NASA Astrophysics Data System (ADS)

    Jiang, Zhen; Klyukin, Konstantin; Alexandrov, Vitaly

    2016-09-01

    A molecular level understanding of the properties of electroactive vanadium species in aqueous solution is crucial for enhancing the performance of vanadium redox flow batteries. Here, we employ Car-Parrinello molecular dynamics simulations based on density functional theory to investigate the hydration structures, first hydrolysis reaction, and diffusion of aqueous V2+, V3+, VO2+, and VO 2+ ions at 300 K. The results indicate that the first hydration shell of both V2+ and V3+ contains six water molecules, while VO2+ is coordinated to five and VO 2+ to three water ligands. The first acidity constants (pKa) estimated using metadynamics simulations are 2.47, 3.06, and 5.38 for aqueous V3+, VO 2+ , and VO2+, respectively, while V2+ is predicted to be a fairly weak acid in aqueous solution with a pKa value of 6.22. We also show that the presence of chloride ions in the first coordination sphere of the aqueous VO 2+ ion has a significant impact on water hydrolysis leading to a much higher pKa value of 4.8. This should result in a lower propensity of aqueous VO 2+ for oxide precipitation reaction in agreement with experimental observations for chloride-based electrolyte solutions. The computed diffusion coefficients of vanadium species in water at room temperature are found to increase as V 3 + < VO 2 + < V O 2 + < V 2 + and thus correlate with the simulated hydrolysis constants, namely, the higher the pKa value, the greater the diffusion coefficient.

  19. Temporal and spatiotemporal variability in comprehensive forearm skin microcirculation assessment during occlusion protocols.

    PubMed

    Strömberg, Tomas; Sjöberg, Folke; Bergstrand, Sara

    2017-09-01

    Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed <1mm/s, Perf SR, <1 ; mid-speed 1-10mm/s, high speed >10mm/s, and total perfusion (Perf SR, tot ); the concentration and oxygenation of red blood cells, C RBC and S O2 ). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perf conv , Perf SR, tot , C RBC and S O2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for S O2 and C RBC . The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, C RBC had a CV<35% and ICC>0.40 (fair-good), and after release this was the case for C RBC (AO and VO), S O2 (VO) and Perf SR, <1 (VO). In conclusion, the skin microcirculation parameters showed excellent temporal repeatability, while the spatiotemporal repeatability especially for perfusion was poorer. The parameters with acceptable repeatability and fair-good agreement were: C RBC during and after release of VO, the Perf SR, <1 after release of VO, the S O2 and the C RBC after release of AO. However, the value of these parameters in discriminating endothelial function remains to be studied. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Proposal for a Specific Aerobic Test for Football Players: The “Footeval”

    PubMed Central

    Manouvrier, Christophe; Cassirame, Johan; Ahmaidi, Saïd

    2016-01-01

    The aim of this study was to evaluate the reproducibility and validity of the “Footeval” test, which evaluates football players’ aerobic level in conditions close to those of football practice (intermittent, including technical skills). Twenty-four highly trained subjects from an elite football academy (17.8 ± 1.4 years, 5 training sessions per week) performed two Footeval sessions in a period of 7 days. Physiological variables measured during these sessions (VO2max 58.1 ± 5.6 and 58.7 ± 6.2 ml·min-1·kg-1; RER 1.18 ± 0.06 and 1.19 ± 0.05; LaMax 11.0 ±1.4 and 10.8 ±1.1 µmol·L-1; HRmax 194 ± 6 and 190 ± 7 b·min-1; Final step 10.71 ± 1.2 and 10.83 ± 1.13 and the RPE = 10) highlighted maximal intensity and confirmed that players reached physiological exhaustion. Comparison of values measured in both sessions showed large to very large correlations (Final level; 0.92, VO2max; 0.79, HRmax; 0.88, LaMax; 0.87) and high ICC (Final level; 0.93, VO2max; 0.87, HRmax; 0.90, LaMax; 0.85) except for RER (r = 0.22, ICC = 0.21). In addition, all subjects performed a time limit (Tlm) exercise with intensity set at maximal aerobic specific speed + 1 km·h-1, in order to check the maximal value obtained during the Footeval test. Statistical analysis comparing VO2max, HRmax and RER from the Footeval and Tlm exercise proved that values from Footeval could be considered as maximal values (r for VO2max; 0.82, HRmax; 0.77 and ICC for VO2max; 0.92, HRmax; 0.91). This study showed that Footeval is a reproducible test that allows maximal aerobic specific speed to be obtained at physiological exhaustion. Moreover, we can also affirm that this test meets the physiological exhaustion criteria as defined in the literature (RER ≥ 1, 1; LaMax ≥ 8 µmol·L-1; HR = HRmax; no increase of VO2 despite the increase of speed; RPE =10). Key points “Footeval” is a new test for football that is able to evaluate aerobic capacity in football specific conditions. This study evaluates reproducibility and validity of the “Footeval” test in elite football players. PMID:27928213

Top