Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.
2014-01-01
Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240
Ungerer, Jacobus P J; Pretorius, Carel J
2014-04-01
Highly-sensitive cardiac troponin (cTn) assays are being introduced into the market. In this study we argue that the classification of cTn assays into sensitive and highly-sensitive is flawed and recommend a more appropriate way to characterize analytical sensitivity of cTn assays. The raw data of 2252 cardiac troponin I (cTnI) tests done in duplicate with a 'sensitive' assay was extracted and used to calculate the cTnI levels in all, including those below the 'limit of detection' (LoD) that were censored. Duplicate results were used to determine analytical imprecision. We show that cTnI can be quantified in all samples including those with levels below the LoD and that the actual margins of error decrease as concentrations approach zero. The dichotomous classification of cTn assays into sensitive and highly-sensitive is theoretically flawed and characterizing analytical sensitivity as a continuous variable based on imprecision at 0 and the 99th percentile cut-off would be more appropriate.
Ryan, J B; Southby, S J; Stuart, L A; Mackay, R; Florkowski, C M; George, P M
2014-07-01
Assays for cardiac troponin (cTn) have undergone improvements in sensitivity and precision in recent years. Increased rates of outliers, however, have been reported on various cTn platforms, typically giving irreproducible, falsely higher results. We aimed to evaluate the outlier rate occurring in patients with elevated cTnI using a contemporary and high-sensitivity assay. All patients with elevated cTnI (up to 300 ng/L) performed over a 21-month period were assayed in duplicate. A contemporary assay (Abbott STAT Troponin-I) was used for the first part of the study and subsequently a high-sensitivity assay (Abbott STAT High-Sensitive Troponin-I) was used. Outliers exceeded a calculated critical difference (CD) (CD = z × √2 × SDAnalytical) where z = 3.5 (for probability of 0.0005) and critical outliers also were on a different side of the decision level. The respective outlier and critical outlier rates were 0.22% and 0.10% for the contemporary assay (n = 4009) and 0.18% and 0.13% for the high-sensitivity assay (n = 3878). There was no significant reduction in outlier rate between the two assays (χ(2) = 0.034, P = 0.854). Fifty-six percent of outliers occurred in samples where cTn was an 'add-on' test (and was stored and refrigerated prior to assay). Despite recent improvements in cTn methods, outliers (including critical outliers) still occur at a low rate in both a contemporary and high-sensitivity cTnI assay. Laboratory and clinical staff should be aware of this potential analytical error, particularly in samples with suboptimal sample handling such as add-on tests. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
2011-01-01
DHEAS. All samples were assayed for salivary DHEA in duplicate using a highly sensitive enzyme immunoassay (Salimetrics, LLC). The test used 50ml of...p , 0.0001, n ¼ 39). Similarly, samples were assayed for salivary DHEAS in duplicate using a highly sensitive enzyme immuno- assay (Salimetrics, LLC...assayed for salivary testosterone. This was performed in duplicate using a highly sensitive enzyme immunoassay (Salimetrics, LLC). The test used 25ml of
Ozeki, Itaru; Nakajima, Tomoaki; Suii, Hirokazu; Tatsumi, Ryoji; Yamaguchi, Masakatsu; Kimura, Mutsuumi; Arakawa, Tomohiro; Kuwata, Yasuaki; Ohmura, Takumi; Hige, Shuhei; Karino, Yoshiyasu; Toyota, Joji
2018-02-01
We investigated the utility of high-sensitivity hepatitis B surface antigen (HBsAg) assays compared with conventional HBsAg assays. Using serum samples from 114 hepatitis B virus (HBV) carriers in whom HBsAg seroclearance was confirmed by conventional HBsAg assays (cut-off value, 0.05 IU/mL), the amount of HBsAg was re-examined by high-sensitivity HBsAg assays (cut-off value, 0.005 IU/mL). Cases negative for HBsAg in both assays were defined as consistent cases, and cases positive for HBsAg in the high-sensitivity HBsAg assay only were defined as discrepant cases. There were 55 (48.2%) discrepant cases, and the range of HBsAg titers determined by high-sensitivity HBsAg assays was 0.005-0.056 IU/mL. Multivariate analysis showed that the presence of nucleos(t)ide analog therapy, liver cirrhosis, and negative anti-HBs contributed to the discrepancies between the two assays. Cumulative anti-HBs positivity rates among discrepant cases were 12.7%, 17.2%, 38.8%, and 43.9% at baseline, 1 year, 3 years, and 5 years, respectively, whereas the corresponding rates among consistent cases were 50.8%, 56.0%, 61.7%, and 68.0%, respectively. Hepatitis B virus DNA negativity rates were 56.4% and 81.4% at baseline, 51.3% and 83.3% at 1 year, and 36.8% and 95.7% at 3 years, among discrepant and consistent cases, respectively. Hepatitis B surface antigen reversion was observed only in discrepant cases. Re-examination by high-sensitivity HBsAg assays revealed that HBsAg was positive in approximately 50% of cases. Cumulative anti-HBs seroconversion rates and HBV-DNA seroclearance rates were lower in these cases, suggesting a population at risk for HBsAg reversion. © 2017 The Japan Society of Hepatology.
Forreryd, Andy; Johansson, Henrik; Albrekt, Ann-Sofie; Lindstedt, Malin
2014-05-16
Allergic contact dermatitis (ACD) develops upon exposure to certain chemical compounds termed skin sensitizers. To reduce the occurrence of skin sensitizers, chemicals are regularly screened for their capacity to induce sensitization. The recently developed Genomic Allergen Rapid Detection (GARD) assay is an in vitro alternative to animal testing for identification of skin sensitizers, classifying chemicals by evaluating transcriptional levels of a genomic biomarker signature. During assay development and biomarker identification, genome-wide expression analysis was applied using microarrays covering approximately 30,000 transcripts. However, the microarray platform suffers from drawbacks in terms of low sample throughput, high cost per sample and time consuming protocols and is a limiting factor for adaption of GARD into a routine assay for screening of potential sensitizers. With the purpose to simplify assay procedures, improve technical parameters and increase sample throughput, we assessed the performance of three high throughput gene expression platforms--nCounter®, BioMark HD™ and OpenArray®--and correlated their performance metrics against our previously generated microarray data. We measured the levels of 30 transcripts from the GARD biomarker signature across 48 samples. Detection sensitivity, reproducibility, correlations and overall structure of gene expression measurements were compared across platforms. Gene expression data from all of the evaluated platforms could be used to classify most of the sensitizers from non-sensitizers in the GARD assay. Results also showed high data quality and acceptable reproducibility for all platforms but only medium to poor correlations of expression measurements across platforms. In addition, evaluated platforms were superior to the microarray platform in terms of cost efficiency, simplicity of protocols and sample throughput. We evaluated the performance of three non-array based platforms using a limited set of transcripts from the GARD biomarker signature. We demonstrated that it was possible to achieve acceptable discriminatory power in terms of separation between sensitizers and non-sensitizers in the GARD assay while reducing assay costs, simplify assay procedures and increase sample throughput by using an alternative platform, providing a first step towards the goal to prepare GARD for formal validation and adaption of the assay for industrial screening of potential sensitizers.
Plagnol, Vincent; Woodhouse, Samuel; Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg; Forshew, Tim
2018-01-01
Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications.
Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg
2018-01-01
Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications. PMID:29543828
Sensitive high-throughput screening for the detection of reducing sugars.
Mellitzer, Andrea; Glieder, Anton; Weis, Roland; Reisinger, Christoph; Flicker, Karlheinz
2012-01-01
The exploitation of renewable resources for the production of biofuels relies on efficient processes for the enzymatic hydrolysis of lignocellulosic materials. The development of enzymes and strains for these processes requires reliable and fast activity-based screening assays. Additionally, these assays are also required to operate on the microscale and on the high-throughput level. Herein, we report the development of a highly sensitive reducing-sugar assay in a 96-well microplate screening format. The assay is based on the formation of osazones from reducing sugars and para-hydroxybenzoic acid hydrazide. By using this sensitive assay, the enzyme loads and conversion times during lignocellulose hydrolysis can be reduced, thus allowing higher throughput. The assay is about five times more sensitive than the widely applied dinitrosalicylic acid based assay and can reliably detect reducing sugars down to 10 μM. The assay-specific variation over one microplate was determined for three different lignocellulolytic enzymes and ranges from 2 to 8%. Furthermore, the assay was combined with a microscale cultivation procedure for the activity-based screening of Pichia pastoris strains expressing functional Thermomyces lanuginosus xylanase A, Trichoderma reesei β-mannanase, or T. reesei cellobiohydrolase 2. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Giachetti, C.; Linnen, J. M.; Kolk, D. P.; Dockter, J.; Gillotte-Taylor, K.; Park, M.; Ho-Sing-Loy, M.; McCormick, M. K.; Mimms, L. T.; McDonough, S. H.
2002-01-01
Various nucleic acid assays have been developed and implemented for diagnostics and therapeutic monitoring of human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) infections. The high-throughput, semiautomated assays described here were developed to provide a method suitable for screening plasma specimens for the presence of HIV-1 and HCV RNAs. Three assays were developed: a multiplex HIV-1/HCV assay for simultaneous detection of HIV-1 and HCV, and discriminatory assays for specific detection of HIV-1 and HCV. The assay systems utilize three proprietary technologies: (i) target capture-based sample preparation, (ii) transcription-mediated amplification (TMA), and (iii) hybridization protection assay (HPA). An internal control is incorporated into each reaction to control for every step of the assay and identify random false-negative reactions. The assays demonstrated a sensitivity of at least 100 copies/ml for each target, and they detected with similar sensitivity all major variants of HCV and HIV-1, including HIV-1 group O strains. Assay sensitivity for one virus was not affected by the presence of the other. The specificity of these TMA-driven assays was ≥99.5% in both normal donor specimens and plasma containing potentially interfering substances or other blood-borne pathogens. Statistical receiver operating characteristic plots of 1 − specificity versus sensitivity data determined very wide analyte cutoff values for each assay at the point at which the assay specificity and sensitivity were both ≥99.5%. The sensitivity, specificity, and throughput capability predict that these assays will be valuable for large-volume plasma screening, either in a blood bank setting or in other diagnostic applications. PMID:12089255
Sensitivity and specificity: twin goals of proteomics assays. Can they be combined?
Wilson, Robert
2013-04-01
A major ambition of proteomics is the provision of assays that can diagnose disease and monitor therapies. These assays are required to be sensitive and specific for individual proteins, and in most cases to quantify more than one protein in the same sample. The two main technologies currently used for proteomics assays are based on mass spectrometry and panels of affinity molecules such as antibodies. In the first part of this review the most sensitive existing assays based on these technologies are described and compared with the gold standard of ELISA. Analytical sensitivity is defined and related to the limit of detection, and analytical specificity is defined and shown to depend on molecular proofreading steps, similar to those applied in living systems whenever there is a need for high fidelity. It is shown that at present neither mass spectrometry nor panels of affinity molecules offer the necessary combination of sensitivity and specificity required for multiplexed assays. In the second part of this review the growing numbers of assays that use additional proofreading steps to combine sensitivity with specificity are described. These include assays based on proximity ligation and slow off-rate modified aptamers. Finally the review considers what improvements might be possible in the near future, and concludes that further development of proteomics assays incorporating advanced proofreading steps are most likely to provide the necessary combination of sensitivity and specificity, without incurring high development costs.
Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian
2017-08-01
High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.
Pai, Madhukar; Kalantri, Shriprakash; Pascopella, Lisa; Riley, Lee W; Reingold, Arthur L
2005-10-01
To summarize, using meta-analysis, the accuracy of bacteriophage-based assays for the detection of rifampicin resistance in Mycobacterium tuberculosis. By searching multiple databases and sources we identified a total of 21 studies eligible for meta-analysis. Of these, 14 studies used phage amplification assays (including eight studies on the commercial FASTPlaque-TB kits), and seven used luciferase reporter phage (LRP) assays. Sensitivity, specificity, and agreement between phage assay and reference standard (e.g. agar proportion method or BACTEC 460) results were the main outcomes of interest. When performed on culture isolates (N=19 studies), phage assays appear to have relatively high sensitivity and specificity. Eleven of 19 (58%) studies reported sensitivity and specificity estimates > or =95%, and 13 of 19 (68%) studies reported > or =95% agreement with reference standard results. Specificity estimates were slightly lower and more variable than sensitivity; 5 of 19 (26%) studies reported specificity <90%. Only two studies performed phage assays directly on sputum specimens; although one study reported sensitivity and specificity of 100 and 99%, respectively, another reported sensitivity of 86% and specificity of 73%. Current evidence is largely restricted to the use of phage assays for the detection of rifampicin resistance in culture isolates. When used on culture isolates, these assays appear to have high sensitivity, but variable and slightly lower specificity. In contrast, evidence is lacking on the accuracy of these assays when they are directly applied to sputum specimens. If phage-based assays can be directly used on clinical specimens and if they are shown to have high accuracy, they have the potential to improve the diagnosis of MDR-TB. However, before phage assays can be successfully used in routine practice, several concerns have to be addressed, including unexplained false positives in some studies, potential for contamination and indeterminate results.
Lechpammer, S; Asea, A; Mallick, R; Zhong, R; Sherman, M Y; Calderwood, S K
2002-01-01
It is now possible to search for new drugs using high-throughput screening of chemical libraries accumulated over the past few years. To detect potential new hyperthermia sensitizers, we are screening for chemical inhibitors of thermotolerance. For the screening of a large chemical library, a rapid and simple assay based on the XTT-tetrazolium salt with the addition of intermediate electron acceptor, phenazine methosulphate (PMS) as a promoter, was developed. It was found that the sensitivity of the XTT/PMS assay is sufficient for assessing thermal cell killing and thermotolerance, although it was highly dependent on cell number and type. When the formazan assay system was challenged with the bioflavonoid drug quercetin (up to 25mm) and validated against the clonogenic cell survival assay, significant decreases in thermotolerant cell viability were observed, directly reflecting inhibition of thermotolerance. Although short-term assays can, in some instances, underestimate overall cell killing, the dose dependency of inhibition of thermotolerance by quercetin recorded in this study by clonogenic and XTT/PMS assays was similar. Application of the XTT/PMS assay in chemical library screening was highly effective in differentiating potential thermotolerance inhibitors from both chemicals with lack of efficacy and from toxic compounds. Taken together, these results show that the XTT/PMS assay, when carried out under careful conditions, is well suited for primary high-flux screen of many thousands of compounds, thus opening up new areas for discovery of hyperthermia sensitizers.
Ran, Ying-Fen; Fields, Conor; Muzard, Julien; Liauchuk, Viktoryia; Carr, Michael; Hall, William; Lee, Gil U
2014-12-07
A sensitive, rapid, and label free magnetic bead aggregation (MBA) assay has been developed that employs superparamagnetic (SPM) beads to capture, purify, and detect model proteins and the herpes simplex virus (HSV). The MBA assay is based on monitoring the aggregation state of a population of SPM beads using light scattering of individual aggregates. A biotin-streptavidin MBA assay had a femtomolar (fM) level sensitivity for analysis times less than 10 minutes, but the response of the assay becomes nonlinear at high analyte concentrations. A MBA assay for the detection of HSV-1 based on a novel peptide probe resulted in the selective detection of the virus at concentrations as low as 200 viral particles (vp) per mL in less than 30 min. We define the parameters that determine the sensitivity and response of the MBA assay, and the mechanism of enhanced sensitivity of the assay for HSV. The speed, relatively low cost, and ease of application of the MBA assay promise to make it useful for the identification of viral load in resource-limited and point-of-care settings where molecular diagnostics cannot be easily implemented.
Zhang, Yanfeng; Lou, Jianlong; Jenko, Kathy L.; Marks, James D.; Varnum, Susan M.
2012-01-01
Botulinum neurotoxins (BoNTs), produced by Clostridium botulinum, are a group of seven (A–G) immunologically distinct proteins and cause the paralytic disease botulism. These toxins are the most poisonous substances known to humans and are potential bioweapon agents. Therefore, it is necessary to develop highly sensitive assays for the detection of BoNTs in both clinical and environmental samples. In the current study, we have developed an enzyme-linked immunosorbent assay (ELISA)-based protein antibody microarray for the sensitive and simultaneous detection of BoNT serotypes A, B, C, D, E, and F. With engineered high-affinity antibodies, the BoNT assays have sensitivities in buffer ranging from 1.3 fM (0.2 pg/ml) to 14.7 fM (2.2 pg/ml). Using clinical and food matrices (serum and milk), the microarray is capable of detecting BoNT serotypes A to F to similar levels as in standard buffer. Cross-reactivity between assays for individual serotype was also analyzed. These simultaneous, rapid, and sensitive assays have the potential to measure botulinum toxins in a high-throughput manner in complex clinical, food, and environmental samples. PMID:22935296
USDA-ARS?s Scientific Manuscript database
A broad-specific and sensitive immunoassay for the detection of sulfonamides was developed by optimizing the conditions of an enzyme-linked immunosorbent assay (ELISA) in regard to different monoclonal antibodies (MAbs), assay format, immunoreagents, and several physicochemical factors (pH, salt, de...
Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian
2017-01-01
High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept. PMID:28856047
Bogestam, Katja; Vondracek, Martin; Karlsson, Mattias; Fang, Hong; Giske, Christian G
2018-01-01
Many countries using sensitive screening methods for detection of carriage of methicillin-resistant Staphylococcus aureus (MRSA) have a sustained low incidence of MRSA infections. For diagnostic laboratories with high sample volumes, MRSA screening requires stability, low maintenance and high performance at a low cost. Herein we designed oligonucleotides for a new nuc targeted hydrolysis probe PCR to replace the standard in-house nuc SybrGreen PCR assay. This new, more time-efficient, PCR assay resulted in a 40% increase in daily sample capacity, with maintained high specificity and sensitivity. The assay was also able to detect Staphylococcus aureus clonal cluster 75 (CC75) lineage strains, recently re-classified as Staphylococcus argenteus, with a sensitivity considerably increased compared to our previous assay. While awaiting consensus if the CC75 lineage of S. aureus should be considered as S. argenteus, and whether methicillin-resistant S. argenteus should be included in the MRSA definition, many diagnostic laboratories need to update their MRSA assay sensitivity/specificity towards this lineage/species. The MRSA screening assay presented in this manuscript is comprised of nuc oligonucleotides separately targeting S. aureus and CC75 lineage strains/S. argenteus, thus providing high user flexibility for the detection of CC75 lineage strains/S. argenteus.
Gene expression analysis using a highly sensitive DNA microarray for colorectal cancer screening.
Koga, Yoshikatsu; Yamazaki, Nobuyoshi; Takizawa, Satoko; Kawauchi, Junpei; Nomura, Osamu; Yamamoto, Seiichiro; Saito, Norio; Kakugawa, Yasuo; Otake, Yosuke; Matsumoto, Minori; Matsumura, Yasuhiro
2014-01-01
Half of all patients with small, right-sided, non-metastatic colorectal cancer (CRC) have negative results for the fecal occult blood test (FOBT). In the present study, the usefulness of CRC screening with a highly sensitive DNA microarray was evaluated in comparison with that by FOBT using fecal samples. A total of 53 patients with CRC and 61 healthy controls were divided into "training" and "validation sets". For the gene profiling, total RNA extracted from 0.5 g of feces was hybridized to a highly sensitive DNA chip. The expressions of 43 genes were significantly higher in the patients with CRC than in healthy controls (p<0.05). In the training set, the sensitivity and specificity of the DNA chip assay using six genes were 85.4% and 85.2%, respectively. On the other hand, in the validation set, the sensitivity and specificity of the DNA chip assay were 85.2% and 85.7%, respectively. The sensitivities of the DNA chip assay were higher than those of FOBT in cases of the small, right-sided, early-CRC, tumor invading up to the muscularis propria (i.e. surface tumor) subgroups. In particular, the sensitivities of the DNA chip assay in the surface tumor and early-CRC subgroups were significantly higher than those of FOBT (p=0.023 and 0.019, respectively.). Gene profiling assay using a highly sensitive DNA chip was more effective than FOBT at detecting patients with small, right-sided, surface tumor, and early-stage CRC.
Simultaneous ultramicroanalysis of both 17-keto-and 17beta-hydroxy androgens in biological fluids.
Ganjam, V K
1976-11-01
Sensitive methods for quantifying androgens were lacking. Therefore, a relatively simple procedure for separating steroids was combined with highly specific assay methods so that eight androgens could be measured with high accuracy, precision and sensitivity. Semi-automated separations on Sephadex LH-20 columns used heptane:methylene chloride:ethanol:water (50:50:1:0.12) and a flow rate of 17.0 min/ml. The six peaks eluted contained androstenedine; androsterone, epiandrosterone and dihydrotestosterone; testosterone and dehydroepiandrosterone; 3alpha-androstanediol; 3beta-androstanediol; and androstenediol. Androstenedione, dehydroepiandrosterone and androstenediol were quantified using specific antisera (sensitivity less than or equal to 75 pg). Testosterone and dihydrotestosterone were measured by competitive protein-binding assays using rabbit TeBG (sensitivity less than or equal to 150 pg). 3alpha- and 3beta-androstanediol were similarly assayed using human TeBG (sensitivity approximately 150 pg). Androsterone was reduced with NaBH4 and the resulting 3alpha-androstanediol was assayed using human TeBG (sensitivity approximately 200 pg). Inter- and intra-assay variations were less than 10% for radioimmunoassays and less than 16% for competitive protein-binding assays over the entire dose response curve.
Rotteveel-de Groot, Dorien M; Ross, H Alec; Janssen, Marcel J R; Netea-Maier, Romana T; Oosting, Janine D; Sweep, Fred C G J; van Herwaarden, Antonius E
2016-08-01
Thyroglobulin (Tg) measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC) after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman-Coulter). Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI) evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL) for the Elecsys Tg II assay. Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04-500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence.
HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT
The rapid and sensitive detection of organophosphate insecticides using a 96 well plate format is reported. Several features of this assay make it attractive for development as a laboratory-based or field screening assay. Acetylcholinesterase (AChE) was stabilized in a gelati...
Saini, Suman; Gupta, V K; Gururaj, K; Singh, D D; Pawaiya, R V S; Gangwar, N K; Mishra, A K; Dwivedi, Deepak; Andani, Dimple; Kumar, Ashok; Goswami, T K
2017-08-01
Brucellosis is one of the leading causes of abortion in domestic animals that imposes costs on both economy and society. The disease is highly zoonotic and poses risk to animal handlers due to its zoonotic nature. It causes stillbirth, loss of kids and abortion in last term of pregnancy. Reproductive damage includes infertility in does and orchitis and epididymitis in breeding bucks, which result in high financial losses to farmers and the agriculture industry as a whole. It requires highly sensitive and specific assays to diagnose the disease at field level. In the current study, a visual loop-mediated isothermal amplification (LAMP) assay and the TaqMan® real-time PCR were developed with high sensitivity and specificity. For the TaqMan® probe, real-time PCR primers were developed using Omp31 gene as target and primers were designed using discontiguous conserved sequences of Omp31 gene. The Omp31 probes were designed by attaching 6-FAM reporter dye at the 5' end and BHQ-1 quencher at the 3' end. Published primers were used for visual LAMP assay targeting the Omp25 gene. Sensitivity of the standardized visual LAMP assay and TaqMan® real-time PCR assay was determined by serial dilution of positive Brucella melitensis DNA (10 2 to 10 -4 ng) obtained from standard culture. The TaqMan® probe real-time assay can detect as low as 100 fg of B. melitensis DNA, whereas culture from vaginal swab washings has a limit of detection (LOD) of only 1 cfu/ml. Similarly, the visual LAMP assay can detect as low as 10 fg of B. melitensis DNA as compared to an LOD of 30 cfu/ml from culture of vaginal swab washings. Both assays were compared with serological tests (serum tube agglutination test (STAT) and indirect enzyme-linked immunosorbent assay (iELISA)) for diagnostic sensitivity and specificity. Diagnostic sensitivities and specificities for TaqMan® real-time PCR vs. LAMP assays were 98 and 100% vs. 100 and 97.8%, respectively. Results of visual LAMP assay indicated that LAMP is a fast, specific, sensitive, inexpensive and suitable method for diagnosis of B. melitensis infection under field conditions. On the other hand, Omp31 TaqMan® probe real-time assay can be used in conjunction with the other field-based diagnostic tests due to its high specificity.
A sensitive branched DNA HIV-1 signal amplification viral load assay with single day turnaround.
Baumeister, Mark A; Zhang, Nan; Beas, Hilda; Brooks, Jesse R; Canchola, Jesse A; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R
2012-01-01
Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) ("Versant Assay") currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16-18 h to 2.5 h, composition of only the "Lysis Diluent" solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements.
Liao, Pei-Hu; Lin, Ruey-Hseng; Yang, Ming-Ling; Li, Yi-Ching; Kuan, Yu-Hsiang
2012-03-01
Chinese hamster ovary (CHO) cells, its lung fibroblasts (V79), and human lymphocytes are routinely used in in vitro cytogenetic assays, which include micronuclei (MN), sister chromatid exchange (SCE), and chromosome aberration (CA) assays. Mitomycin C (MMC), a DNA cross-link alkylating agent, is both an anticancer medicine and a carcinogen. To study the differential representative values of cell types in MMC-treated cytogenetic assays and its upstream factor, cysteine aspartic acid-specific protease (caspase)-3. Among the chosen cell types, lymphocytes expressed the highest sensitivity in all three MMC-induced assays, whereas CHO and V79 showed varied sensitivity in different assays. In MN assay, the sensitivity of CHO is higher than or equal to V79; in SCE assay, the sensitivity of CHO is the same as V79; and in CA assay, the sensitivity of CHO is higher than V79. In-depth analysis of CA revealed that in chromatid breaks and dicentrics formation, lymphocyte was the most sensitive of all and CHO was more sensitive than V79; and in acentrics and interchanges formation, lymphocyte was much more sensitive than the others. Furthermore, we found caspase-3 activity plays an important role in MMC-induced cytogenetic assays, with MMC-induced caspase-3 activity resulting in more sensitivity in lymphocytes than in CHO and V79. Based on these findings, lymphocyte will make a suitable predictive or representative control reference in cytogenetic assays and caspase-3 activity with its high specificity, positive predictive value, and sensitivity.
Wessels, Uwe; Schick, Eginhard; Ritter, Mirko; Kowalewsky, Frank; Heinrich, Julia; Stubenrauch, Kay
2017-06-01
Bridging immunoassays for detection of antidrug antibodies (ADAs) are typically susceptible to high concentrations of residual drug. Sensitive drug-tolerant assays are, therefore, needed. An immune complex assay to detect ADAs against therapeutic antibodies bearing Pro329Gly mutation was established. The assay uses antibodies specific for the Pro329Gly mutation for capture and human soluble Fcγ receptor for detection. When compared with a bridging assay, the new assay showed similar precision, high sensitivity to IgG1 ADA and dramatically improved drug tolerance. However, it was not able to detect early (IgM-based) immune responses. Applied in combination with a bridging assay, the novel assay serves as orthogonal assay for immunogenicity assessment and allows further characterization of ADA responses.
Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.
Nagatsu, T; Oka, K; Kato, T
1979-07-21
A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.
Hartl, Barbara; Zeller, Iris; Manhart, Angelika; Selitsch, Brigitte; Lass-Flörl, Cornelia; Willinger, Birgit
2018-06-01
Because of their high mortality rates and non-specific symptoms, invasive Candida infections pose a huge diagnostic and therapeutic challenge. In this study, we evaluated the three mannan antigen assays Platelia, Platelia Plus and Serion, and the (1-3)-β-D-glucan assay Fungitell in a group of high-risk (hematological and surgical) patients. Test results of 305 patients hospitalized at the Vienna General Hospital and the University Hospital of Innsbruck were retrospectively analyzed. We assessed the test accuracy by means of descriptive statistics. Nine (2.95%) patients were affected by invasive candidiasis (IC), and 25 (8.2%) patients had a probable/possible infection. The majority of patients (271; 88.9%) showed no signs of infection. The Platelia and Serion mannan assays had a low sensitivity (65% and 52%, respectively), but high specificity (98% for both tests). The newer version of the Platelia assay, the Platelia Plus, had a higher sensitivity (85%) but a lower specificity (89%). The sensitivity of the Fungitell assay was high (100%), while its specificity was low (58%). The positive predictive values were 0.48 for the Platelia and 0.41 for the Serion assay, 0.26 for the Platelia Plus and 0.09 for the Fungitell assay. Our limited, retrospective study suggests the efficacy of mannan assays as screening (Platelia Plus) and confirmatory (Serion) tests, while the Fungitell assay can be used to exclude invasive Candida infections.
A Sensitive Branched DNA HIV-1 Signal Amplification Viral Load Assay with Single Day Turnaround
Baumeister, Mark A.; Zhang, Nan; Beas, Hilda; Brooks, Jesse R.; Canchola, Jesse A.; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R.
2012-01-01
Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) (“Versant Assay”) currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16–18 h to 2.5 h, composition of only the “Lysis Diluent” solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements. PMID:22479381
Rahman, M K; Nagatsu, T; Kato, T
1980-12-12
This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.
Application of immuno-PCR assay for the detection of serum IgE specific to Bermuda allergen.
Rahmatpour, Samine; Khan, Amjad Hayat; Nasiri Kalmarzi, Rasoul; Rajabibazl, Masoumeh; Tavoosidana, Gholamreza; Motevaseli, Elahe; Zarghami, Nosratollah; Sadroddiny, Esmaeil
2017-04-01
In vivo and in vitro tests are the two major ways of identifying the triggering allergens in sensitized individuals with allergic symptoms. Both methods are equally significant in terms of sensitivity and specificity. However, in certain circumstances, in vitro methods are highly preferred because they circumvent the use of sensitizing drugs in patients. In current study, we described a highly sensitive immuno-PCR (iPCR) assay for serum IgE specific to Bermuda allergens. Using oligonucleotide-labelled antibody, we used iPCR for the sensitive detection of serum IgE. The nucleotide sequence was amplified using conventional PCR and the bands were visualized on 2.5% agarose gel. Results demonstrated a 100-fold enhancement in sensitivity of iPCR over commercially available enzyme-linked immunosorbent assay (ELISA) kit. Our iPCR method was highly sensitive for Bermuda-specific serum IgE and could be beneficial in allergy clinics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua
2017-01-01
Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.
Crouch, C F
1995-01-01
AIMS--To evaluate the clinical performance of enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence. METHODS--Classification of routine clinical samples from the originating laboratories was compared with that obtained using the chemiluminescence based assays. Resolution of discordant results was achieved by testing in alternative enzyme immunoassays (IgM) or by an independent laboratory using the dye test (IgG). RESULTS--Compared with resolved data, the IgM assay was found to be highly specific (100%) with a cut off selected to give optimal performance with respect to both the early detection of specific IgM and the detection of persistent levels of specific IgM (sensitivity 98%). Compared with resolved data, the IgG assay was shown to have a sensitivity and a specificity of 99.4%. CONCLUSIONS--The Amerlite Toxo IgM assay possesses high levels of sensitivity and specificity. Assay interference due to rheumatoid factor like substances is not a problem. The Amerlite Toxo IgG assay possesses good sensitivity and specificity, but is less sensitive for the detection of seroconversion than methods detecting both IgG and IgM. PMID:7560174
Chris Maple, P A; Gunn, Annabel; Sellwood, Jane; Brown, David W G; Gray, Jim J
2009-02-01
The performance of fifteen, commercially available, VZV IgG assays and an "in house" indirect immunofluorescence (IF) assay has been compared to a reference VZV IgG time resolved immunofluorescence assay (VZV TRFIA). A panel of 273 VZV TRFIA IgG positive serum samples and 136 VZV TRFIA IgG susceptible sera, collected from a number of UK hospitals was used. Irrespective of the interpretation of equivocal results the most sensitive assays were Dade Behring EIA (97.4%), "in house" IF (95.2%), Human EIA (92.3%) and Becton Dickinson latex agglutination (94.1%). The least sensitive assays were Virion EIA (69.6%), Diesse EIA (68.9%) and Diasys EIA (68.5%). The least sensitive (<70%) assays all had >99.0% specificity whereas the most sensitive assays had lower specificities; for example, Dade Behring EIA had a specificity of 69.9% when equivocals were treated as VZV IgG negative. For some assays e.g. Dade Behring EIA there were major discrepancies between our findings and those reported by the manufacturer which may reflect the constitution of the panel(s) of sera used for evaluation or the reference method adopted or the choice of cut-off criteria (particularly relevant to our findings for the Behring EIA). Care must be taken to choose an assay with high specificity in order to accurately assess the need for vaccination or immunoprophylaxis; however, high sensitivity is preferable to prevent inappropriate and expensive treatment.
Wolf, B H; Weening, R S; Schutgens, R B; van Noorden, C J; Vogels, I M; Nagelkerke, N J
1987-09-30
The results of a quantitative spectrophotometric enzyme assay, a fluorescent spot test and a cytochemical assay for glucose-6-phosphate dehydrogenase deficiency were compared systematically. The high sensitivity of the spectrophotometric assay and the fluorescent spot test in the detection of severely deficient individuals was confirmed. For the detection of heterozygote females, however both tests were unreliable; the sensitivities of the fluorescent spot test and the spectrophotometric assay being 32% and 11% respectively. Specificities for both tests were high (99%). Introduction of the ratio of glucose-6-phosphate dehydrogenase and pyruvate kinase (G-6-PD/PK ratio) activities increased the sensitivity of the spectrophotometric assay to nearly 100%. It is concluded that the fluorescent spot test should be used for the diagnosis of G-6-PD deficiency in developing countries; whereas if spectrophotometric enzyme assays are available, the G-6-PD/PK ratio should always be performed. In cases where the ratio is less than 0.70, cytochemical analysis is indicated.
2006-11-26
with controlled micro and nanostructure for highly selective, high sensitivity assays. The process was modeled and a procedure for fabricating SERS...small volumes with controlled micro and nanostructure for highly selective, high sensitivity assays. We proved the feasibility of the technique and...films templated by colloidal crystals. The control over the film structure allowed optimizing their performance for potential sensor applications. The
Settivari, Raja S; Gehen, Sean C; Amado, Ricardo Acosta; Visconti, Nicolo R; Boverhof, Darrell R; Carney, Edward W
2015-07-01
Assessment of skin sensitization potential is an important component of the safety evaluation process for agrochemical products. Recently, non-animal approaches including the KeratinoSens™ assay have been developed for predicting skin sensitization potential. Assessing the utility of the KeratinoSens™ assay for use with multi-component mixtures such as agrochemical formulations has not been previously evaluated and is a significant need. This study was undertaken to evaluate the KeratinoSens™ assay prediction potential for agrochemical formulations. The assay was conducted for 8 agrochemical active ingredients (AIs) including 3 sensitizers (acetochlor, meptyldinocap, triclopyr), 5 non-sensitizers (aminopyralid, clopyralid, florasulam, methoxyfenozide, oxyfluorfen) and 10 formulations for which in vivo sensitization data were available. The KeratinoSens™ correctly predicted the sensitization potential of all the AIs. For agrochemical formulations it was necessary to modify the standard assay procedure whereby the formulation was assumed to have a common molecular weight. The resultant approach correctly predicted the sensitization potential for 3 of 4 sensitizing formulations and all 6 non-sensitizing formulations when compared to in vivo data. Only the meptyldinocap-containing formulation was misclassified, as a result of high cytotoxicity. These results demonstrate the promising utility of the KeratinoSens™ assay for evaluating the skin sensitization potential of agrochemical AIs and formulations. Copyright © 2015 Elsevier Inc. All rights reserved.
Advantages and application of label-free detection assays in drug screening.
Cunningham, Brian T; Laing, Lance G
2008-08-01
Adoption is accelerating for a new family of label-free optical biosensors incorporated into standard format microplates owing to their ability to enable highly sensitive detection of small molecules, proteins and cells for high-throughput drug discovery applications. Label-free approaches are displacing other detection technologies owing to their ability to provide simple assay procedures for hit finding/validation, accessing difficult target classes, screening the interaction of cells with drugs and analyzing the affinity of small molecule inhibitors to target proteins. This review describes several new drug discovery applications that are under development for microplate-based photonic crystal optical biosensors and the key issues that will drive adoption of the technology. Microplate-based optical biosensors are enabling a variety of cell-based assays, inhibition assays, protein-protein binding assays and protein-small molecule binding assays to be performed with high-throughput and high sensitivity.
Development of rapid and sensitive high throughput pharmacologic assays for marine phycotoxins.
Van Dolah, F M; Finley, E L; Haynes, B L; Doucette, G J; Moeller, P D; Ramsdell, J S
1994-01-01
The lack of rapid, high throughput assays is a major obstacle to many aspects of research on marine phycotoxins. Here we describe the application of microplate scintillation technology to develop high throughput assays for several classes of marine phycotoxin based on their differential pharmacologic actions. High throughput "drug discovery" format microplate receptor binding assays developed for brevetoxins/ciguatoxins and for domoic acid are described. Analysis for brevetoxins/ciguatoxins is carried out by binding competition with [3H] PbTx-3 for site 5 on the voltage dependent sodium channel in rat brain synaptosomes. Analysis of domoic acid is based on binding competition with [3H] kainic acid for the kainate/quisqualate glutamate receptor using frog brain synaptosomes. In addition, a high throughput microplate 45Ca flux assay for determination of maitotoxins is described. These microplate assays can be completed within 3 hours, have sensitivities of less than 1 ng, and can analyze dozens of samples simultaneously. The assays have been demonstrated to be useful for assessing algal toxicity and for assay-guided purification of toxins, and are applicable to the detection of biotoxins in seafood.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yanfeng; Lou, Jianlong; Jenko, Kathryn L.
2012-11-15
Botulinum neurotoxins (BoNTs), produced by Clostridium botulinum, are a group of seven (A-G) immunologically distinct proteins and cause the paralytic disease botulism. These toxins are the most poisonous substances known to humans and are potential bioweapon agents. Therefore, it is necessary to develop highly sensitive assays for the detection of BoNTs in both clinical and environmental samples. In the present study, we have developed an ELISA-based protein antibody microarray for the sensitive and simultaneous detection of BoNT serotype A, B, C, D, E and F. With engineered high-affinity antibodies, the assays have sensitivities in buffer of 8 fM (1.2 pg/mL)more » for serotypes A and B, and 32 fM (4.9 pg/mL) for serotypes C, D, E, and F. Using clinical and environmental samples (serum and milk), the microarray is capable of detecting BoNT/A-F to the same levels as in standard buffer. Cross reactivity between assays for individual serotype was also analyzed. These simultaneous, rapid, and sensitive assays have the potential to measure botulinum toxins in a high-throughput manner in complex clinical or environmental samples.« less
In vitro assay of Staphylococcus aureus enterotoxin A activity in food.
Rasooly, L; Rose, N R; Shah, D B; Rasooly, A
1997-01-01
Staphylococcus aureus enterotoxin A (SEA) is a leading cause of food poisoning. The current test for functional activity of SEA requires monkeys or kittens. The major drawbacks of animal assays are lack of quantitation, poor reproducibility, low sensitivity, and high cost. In this report we describe and evaluate an alternative assay using T-cell proliferation to measure SEA activity in food. Human and rat lymphocytes proliferate in response to concentrations of SEA as low as 1 pg/ml, well below the pathogenic dose of 100 ng. This proliferation assay is highly sensitive, quantitative, and simple. Nonradioactive assays of T-cell proliferation were also suitable for detecting and measuring SEA, although with a 10-fold lower sensitivity. To evaluate the utility of this assay for food testing, four different food samples were mixed with SEA. In each sample, SEA was detected at a concentration of 1 ng/ml. Heat-inactivated SEA produced no detectable proliferation. These results demonstrate that an in vitro cell proliferation assay is an advantageous alternative to existing animal assays for measuring SEA activity in food. PMID:9172356
CAO, Lili; CHENG, Ronghua; YAO, Lin; YUAN, Shuxian; YAO, Xinhua
2013-01-01
ABSTRACT The Loop-mediated isothermal amplification (LAMP) method amplifies DNA with high simply, specificity, sensitivity and rapidity. In this study, A LAMP assay with 6 primers targeting a highly conserved region of the GRA1 gene was developed to diagnose Toxoplasma gondii. The reaction time of the LAMP assay was shortened to 30 min after optimizing the reaction system. The LAMP assay was found to be highly specific and stable. The detection limit of the LAMP assay was 10 copies, the same as that of the conventional PCR. We used the LAMP assay to develop a real-time fluorogenic protocol to quantitate T. gondii DNA and generated a log-linear regression plot by plotting the time-to-threshold values against genomic equivalent copies. Furthermore, the LAMP assay was applied to detect T. gondii DNA in 423 blood samples and 380 lymph node samples from 10 pig farms, and positive results were obtained for 7.8% and 8.2% of samples, respectively. The results showed that the LAMP method is slightly more sensitive than conventional PCR (6.1% and 7.6%). Positive samples obtained from 6 pig farms. The LAMP assay established in this study resulted in simple, specific, sensitive and rapid detection of T. gondii DNA and is expected to play an important role in clinical detection of T. gondii. PMID:23965849
Shen, Xin-Xin; Qiu, Fang-Zhou; Zhao, Huai-Long; Yang, Meng-Jie; Hong, Liu; Xu, Song-Tao; Zhou, Shuai-Feng; Li, Gui-Xia; Feng, Zhi-Shan; Ma, Xue-Jun
2018-03-01
The sensitivity of qRT-PCR assay is not adequate for the detection of the samples with lower viral load, particularly in the cerebrospinal fluid (CSF) of patients. Here, we present the development of a highly sensitive real-time nested RT-PCR (RTN RT-PCR) assay in a single closed tube for detection of human enterovirus (HEV). The clinical performance of both RTN RT-PCR and qRT-PCR was also tested and compared using 140 CSF and fecal specimens. The sensitivities of RTN RT-PCR assay for EV71, Coxsackievirus A (CVA)16, CVA6 and CVA10 achieved 10 -8 dilution with a corresponding Ct value of 38.20, 36.45, 36.75, and 36.45, respectively, which is equal to traditional two-step nested RT-PCR assay and approximately 2-10-fold lower than that of qRT-PCR assay. The specificity of RTN RT-PCR assay was extensively analyzed insilico and subsequently verified using the reference isolates and clinical samples. Sixteen qRT-PCR-negative samples were detected by RTN RT-PCR and a variety of enterovirus serotypes was identified by sequencing of inner PCR products. We conclude RTN RT-PCR is more sensitive than qRT-PCR for the detection of HEV in clinical samples. Copyright © 2017 Elsevier Inc. All rights reserved.
Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui
2017-01-01
Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation. PMID:29084241
González-Herrera, Lucas; Valenzuela, Aurora; Ramos, Valentín; Blázquez, Antonia; Villanueva, Enrique
2016-06-01
The main objective of this study was to test, for the first time, a highly sensitive cardiac troponin T (cTnThs) assay in postmortem serum and pericardial fluid and to evaluate cardiac troponin T (cTnT) levels and their stability after death at different postmortem intervals, in an attempt to determine the viability of the cTnThs assay in the postmortem diagnosis of the cause of death. cTnT levels were determined in serum and pericardial fluid samples taken from 58 cadavers at known postmortem intervals, whose causes of death were categorized into the following groups: (1) sudden cardiac deaths, (2) multiple trauma, (3) mechanical asphyxia, and (4) other natural deaths. cTnT was determined by inmunoassay, using the Troponin T highly sensitive STAT assay (Roche(®)). Average cTnT levels measured by a highly sensitive assay in postmortem serum were markedly higher than clinical serum levels. Moreover, similar results, higher cTnT levels in postmortem pericardial fluid, were obtained when compared to levels found in pericardial fluid taken from two living patients during coronary artery bypass surgery. cTnT levels in both postmortem fluids remained stable for up to 34 h after death. No differences in cTnT levels in either postmortem fluid by sex and age were detected. Levels of cTnT found in pericardial fluid in the other natural deaths group were significantly lower than the cTnT levels found in that postmortem fluid from any of the other causes of death groups. It is therefore reasonable to conclude that determination of cTnT by a highly sensitive assay in pericardial fluid can provide forensic pathologists with a complementary test to the diagnosis of cause of death.
Shapiro, Adam B; Livchak, Stephania; Gao, Ning; Whiteaker, James; Thresher, Jason; Jahić, Haris; Huang, Jian; Gu, Rong-Fang
2012-03-01
A novel assay for the NADPH-dependent bacterial enzyme UDP-N-acetylenolpyruvylglucosamine reductase (MurB) is described that has nanomolar sensitivity for product formation and is suitable for high-throughput applications. MurB catalyzes an essential cytoplasmic step in the synthesis of peptidoglycan for the bacterial cell wall, reduction of UDP-N-acetylenolpyruvylglucosamine to UDP-N-acetylmuramic acid (UNAM). Interruption of this biosynthetic pathway leads to cell death, making MurB an attractive target for antibacterial drug discovery. In the new assay, the UNAM product of the MurB reaction is ligated to L-alanine by the next enzyme in the peptidoglycan biosynthesis pathway, MurC, resulting in hydrolysis of adenosine triphosphate (ATP) to adenosine diphosphate (ADP). The ADP is detected with nanomolar sensitivity by converting it to oligomeric RNA with polynucleotide phosphorylase and detecting the oligomeric RNA with a fluorescent dye. The product sensitivity of the new assay is 1000-fold greater than that of the standard assay that follows the absorbance decrease resulting from the conversion of NADPH to NADP(+). This sensitivity allows inhibitor screening to be performed at the low substrate concentrations needed to make the assay sensitive to competitive inhibition of MurB.
Bass, Chris; Nikou, Dimitra; Donnelly, Martin J; Williamson, Martin S; Ranson, Hilary; Ball, Amanda; Vontas, John; Field, Linda M
2007-01-01
Background Knockdown resistance (kdr) is a well-characterized mechanism of resistance to pyrethroid insecticides in many insect species and is caused by point mutations of the pyrethroid target site the para-type sodium channel. The presence of kdr mutations in Anopheles gambiae, the most important malaria vector in Africa, has been monitored using a variety of molecular techniques. However, there are few reports comparing the performance of these different assays. In this study, two new high-throughput assays were developed and compared with four established techniques. Methods Fluorescence-based assays based on 1) TaqMan probes and 2) high resolution melt (HRM) analysis were developed to detect kdr alleles in An. gambiae. Four previously reported techniques for kdr detection, Allele Specific Polymerase Chain Reaction (AS-PCR), Heated Oligonucleotide Ligation Assay (HOLA), Sequence Specific Oligonucleotide Probe – Enzyme-Linked ImmunoSorbent Assay (SSOP-ELISA) and PCR-Dot Blot were also optimized. The sensitivity and specificity of all six assays was then compared in a blind genotyping trial of 96 single insect samples that included a variety of kdr genotypes and African Anopheline species. The relative merits of each assay was assessed based on the performance in the genotyping trial, the length/difficulty of each protocol, cost (both capital outlay and consumable cost), and safety (requirement for hazardous chemicals). Results The real-time TaqMan assay was both the most sensitive (with the lowest number of failed reactions) and the most specific (with the lowest number of incorrect scores). Adapting the TaqMan assay to use a PCR machine and endpoint measurement with a fluorimeter showed a slight reduction in sensitivity and specificity. HRM initially gave promising results but was more sensitive to both DNA quality and quantity and consequently showed a higher rate of failure and incorrect scores. The sensitivity and specificity of AS-PCR, SSOP-ELISA, PCR Dot Blot and HOLA was fairly similar with a small number of failures and incorrect scores. Conclusion The results of blind genotyping trials of each assay indicate that where maximum sensitivity and specificity are required the TaqMan real-time assay is the preferred method. However, the cost of this assay, particularly in terms of initial capital outlay, is higher than that of some of the other methods. TaqMan assays using a PCR machine and fluorimeter are nearly as sensitive as real-time assays and provide a cost saving in capital expenditure. If price is a primary factor in assay choice then the AS-PCR, SSOP-ELISA, and HOLA are all reasonable alternatives with the SSOP-ELISA approach having the highest throughput. PMID:17697325
Performance characteristics of the ARCHITECT anti-HCV assay.
Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter
2005-10-01
The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.
Stancoven, Amy B; Shiue, Angela B; Khera, Amit; Pinkston, Kristi; Hashim, Ibrahim A; Wang, Andrew; de Lemos, James A; Peterson, Gail E
2011-08-01
Troponin levels have been correlated with adverse outcomes in multiple disease processes, including congestive heart failure, acute coronary syndromes, sepsis, and, in a few small series, infective endocarditis. We hypothesized that a novel measurement of troponin using a highly sensitive assay would correlate with adverse outcomes when prospectively studied in patients with infective endocarditis. At a single center in the International Collaboration on Endocarditis, 42 patients met the inclusion criteria and underwent testing for cardiac troponin T (cTnT) using both a standard and a highly sensitive precommercial assay. The cTnT levels were associated with the prespecified primary composite outcome of death, central nervous system event, and cardiac abscess. Secondary outcomes included the individual components of the composite outcome and the need for cardiac surgery. A receiver operating characteristic curve was derived and used to identify the optimal cutpoint for cTnT using the highly sensitive assay. cTnT was detectable with the highly sensitive assay in 39 (93%) of 42 patients with infective endocarditis and with the standard assay in 25 (56%) of 42 (p <0.05). Of the 42 patients, 15 experienced the composite outcome, 4 died, 9 had a central nervous system event, and 5 had a cardiac abscess. With the hs-cTnT assay, the median cTnT was greater in the patients who experienced the primary outcome (0.12 vs 0.02 ng/ml, p <0.05). According to the receiver operating characteristic curve analysis (area under the curve of 0.74), cTnT levels of ≥0.08 ng/ml produced optimal specificity (78%) for the primary outcome. The patients with a cTnT level of ≥0.08 ng/ml were more likely to experience the primary outcome (odds ratio 7.0, 95% confidence interval 1.7 to 28.6, p <0.01) and a central nervous system event (odds ratio 9.3, 95% confidence interval 1.3 to 24.1, p = 0.02). In conclusion, cTnT is detectable in 93% of patients with infective endocarditis using a novel highly sensitive assay, with higher levels correlating with poor clinical outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
An assay was developed for the detection of Pineapple mealybug wilt associated virus-2 (PMWaV-2), an important factor in the etiology of mealybug wilt of pineapple. The assay combines reverse transcription of RNA isolated from pineapple with a specific and very sensitive, single, closed-tube nested ...
Natsch, Andreas; Gfeller, Hans
2008-12-01
A key step in the skin sensitization process is the formation of a covalent adduct between skin sensitizers and endogenous proteins and/or peptides in the skin. Based on this mechanistic understanding, there is a renewed interest in in vitro assays to determine the reactivity of chemicals toward peptides in order to predict their sensitization potential. A standardized peptide reactivity assay yielded a promising predictivity. This published assay is based on high-performance liquid chromatography with ultraviolet detection to quantify peptide depletion after incubation with test chemicals. We had observed that peptide depletion may be due to either adduct formation or peptide oxidation. Here we report a modified assay based on both liquid chromatography-mass spectrometry (LC-MS) analysis and detection of free thiol groups. This approach allows simultaneous determination of (1) peptide depletion, (2) peptide oxidation (dimerization), (3) adduct formation, and (4) thiol reactivity and thus generates a more detailed characterization of the reactivity of a molecule. Highly reactive molecules are further discriminated with a kinetic measure. The assay was validated on 80 chemicals. Peptide depletion could accurately be quantified both with LC-MS detection and depletion of thiol groups. The majority of the moderate/strong/extreme sensitizers formed detectable peptide adducts, but many sensitizers were also able to catalyze peptide oxidation. Whereas adduct formation was only observed for sensitizers, this oxidation reaction was also observed for two nonsensitizing fragrance aldehydes, indicating that peptide depletion might not always be regarded as sufficient evidence for rating a chemical as a sensitizer. Thus, this modified assay gives a more informed view of the peptide reactivity of chemicals to better predict their sensitization potential.
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-04-01
We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.
Four human Plasmodium species quantification using droplet digital PCR.
Srisutham, Suttipat; Saralamba, Naowarat; Malleret, Benoit; Rénia, Laurent; Dondorp, Arjen M; Imwong, Mallika
2017-01-01
Droplet digital polymerase chain reaction (ddPCR) is a partial PCR based on water-oil emulsion droplet technology. It is a highly sensitive method for detecting and delineating minor alleles from complex backgrounds and provides absolute quantification of DNA targets. The ddPCR technology has been applied for detection of many pathogens. Here the sensitive assay utilizing ddPCR for detection and quantification of Plasmodium species was investigated. The assay was developed for two levels of detection, genus specific for all Plasmodium species and for specific Plasmodium species detection. The ddPCR assay was developed based on primers and probes specific to the Plasmodium genus 18S rRNA gene. Using ddPCR for ultra-sensitive P. falciparum assessment, the lower level of detection from concentrated DNA obtained from a high volume (1 mL) blood sample was 11 parasites/mL. For species identification, in particular for samples with mixed infections, a duplex reaction was developed for detection and quantification P. falciparum/ P. vivax and P. malariae/ P. ovale. Amplification of each Plasmodium species in the duplex reaction showed equal sensitivity to singleplex single species detection. The duplex ddPCR assay had higher sensitivity to identify minor species in 32 subpatent parasitaemia samples from Cambodia, and performed better than real-time PCR. The ddPCR assay shows high sensitivity to assess very low parasitaemia of all human Plasmodium species. This provides a useful research tool for studying the role of the asymptomatic parasite reservoir for transmission in regions aiming for malaria elimination.
Lee, Sook-Kyung; Cheng, Nancy; Hull-Ryde, Emily; Potempa, Marc; Schiffer, Celia A; Janzen, William; Swanstrom, Ronald
2013-07-23
The matrix/capsid processing site in the HIV-1 Gag precursor is likely the most sensitive target to inhibit HIV-1 replication. We have previously shown that modest incomplete processing at the site leads to a complete loss of virion infectivity. In the study presented here, a sensitive assay based on fluorescence polarization that can monitor cleavage at the MA/CA site in the context of the folded protein substrate is described. The substrate, an MA/CA fusion protein, was labeled with the fluorescein-based FlAsH (fluorescein arsenical hairpin) reagent that binds to a tetracysteine motif (CCGPCC) that was introduced within the N-terminal domain of CA. By limiting the size of CA and increasing the size of MA (with an N-terminal GST fusion), we were able to measure significant differences in polarization values as a function of HIV-1 protease cleavage. The sensitivity of the assay was tested in the presence of increasing amounts of an HIV-1 protease inhibitor, which resulted in a gradual decrease in the fluorescence polarization values demonstrating that the assay is sensitive in discerning changes in protease processing. The high-throughput screening assay validation in 384-well plates showed that the assay is reproducible and robust with an average Z' value of 0.79 and average coefficient of variation values of <3%. The robustness and reproducibility of the assay were further validated using the LOPAC(1280) compound library, demonstrating that the assay provides a sensitive high-throughput screening platform that can be used with large compound libraries for identifying novel maturation inhibitors targeting the MA/CA site of the HIV-1 Gag polyprotein.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cary,; Bruce, R; Stubben, Christopher J
The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.
Cook, Linda; Ng, Ka-Wing; Bagabag, Arthur; Corey, Lawrence; Jerome, Keith R.
2004-01-01
Hepatitis C virus (HCV) infection is an increasing health problem worldwide. Quantitative assays for HCV viral load are valuable in predicting response to therapy and for following treatment efficacy. Unfortunately, most quantitative tests for HCV RNA are limited by poor sensitivity. We have developed a convenient, highly sensitive real-time reverse transcription-PCR assay for HCV RNA. The assay amplifies a portion of the 5′ untranslated region of HCV, which is then quantitated using the TaqMan 7700 detection system. Extraction of viral RNA for our assay is fully automated with the MagNA Pure LC extraction system (Roche). Our assay has a 100% detection rate for samples containing 50 IU of HCV RNA/ml and is linear up to viral loads of at least 109 IU/ml. The assay detects genotypes 1a, 2a, and 3a with equal efficiency. Quantitative results by our assay correlate well with HCV viral load as determined by the Bayer VERSANT HCV RNA 3.0 bDNA assay. In clinical use, our assay is highly reproducible, with high and low control specimens showing a coefficient of variation for the logarithmic result of 2.8 and 7.0%, respectively. The combination of reproducibility, extreme sensitivity, and ease of performance makes this assay an attractive option for routine HCV viral load testing. PMID:15365000
Screening for endocrine-disrupting chemicals (EDCs) requires sensitive, scalable assays. Current high-throughput screening (HTPS) approaches for estrogenic and androgenic activity yield rapid results, but many are not sensitive to physiological hormone concentrations, suggesting ...
Gheit, Tarik; Tommasino, Massimo
2011-01-01
Epidemiological and functional studies have clearly demonstrated that certain types of human papillomavirus (HPV) from the genus alpha of the HPV phylogenetic tree, referred to as high-risk (HR) types, are the etiological cause of cervical cancer. Several methods for HPV detection and typing have been developed, and their importance in clinical and epidemiological studies has been well demonstrated. However, comparative studies have shown that several assays have different sensitivities for the detection of specific HPV types, particularly in the case of multiple infections. In this chapter, we describe a novel one-shot method for the detection and typing of 19 mucosal HR HPV types (types 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 70, 73, and 82). The assay combines the advantages of the multiplex PCR methods, i.e., high sensitivity and the possibility to perform multiple amplifications in a single reaction, with an array primer extension (APEX) assay. The latter method offers the benefits of Sanger dideoxy sequencing with the high-throughput potential of the microarray. Initial studies have revealed that the assay is very sensitive in detecting multiple HPV infections.
Highly variable sensitivity of five binding and two bio-assays for TSH-receptor antibodies.
Diana, T; Wüster, C; Kanitz, M; Kahaly, G J
2016-10-01
TSH-receptor (TSHR) antibodies (Ab) can be measured with binding or bio-assays. Sensitivity and specificity of five binding and two bio-assays were compared. TSHR-blocking (TBAb) and TSHR-stimulating (TSAb) Ab were measured with reporter bio-assays. Blocking activity was defined as percent inhibition of luciferase expression relative to induction with bTSH alone. TSAb was reported as percentage of specimen-to-reference ratio (SRR%). TSHR-binding inhibitory immunoglobulins (TBII) were measured with Kronus, Dynex, Kryptor, Cobas, and Immulite. Sixty patients with Graves' disease (GD), 20 with Hashimoto's thyroiditis (HT), and 20 healthy controls (C) were included. C tested negative in all assays (specificity 100 %) while all 60 hyperthyroid GD patients tested positive in the TSAb bio-assay (sensitivity 100 %). Among these 60 GD patients, 20 had low TSAb positivity (SRR% 140-279), but were TBII positive in only 20 (100 %), 7 (35 %), 9 (45 %), 11 (55 %), and 18 (90 %) using the Kronus, Dynex, Kryptor, Cobas, and Immulite, respectively. In 20 moderate TSAb-positive (SRR% 280-420) patients, TBII tested positive in 20 (100 %), 14 (70 %), 13 (65 %), 16 (80 %), and 19 (95 %), respectively. The high (SRR% > 420) TSAb-positive patients were all TBII positive. All 20 hypothyroid HT patients tested TBAb positive (sensitivity 100 %) in the bio-assay while they tested TBII positive in 20 (100 %), 18 (90 %), 20, 20, and 18, respectively. Results obtained with two luminometers correlated for TSAb positive (r = 0.99, p < 0.001), TBAb positive (r = 0.88, p < 0.001), and C (r = 0.86, p < 0.001). None of the binding assays differentiated between TSAb and TBAb. Sensitivity is highly variable between binding and bio-assays for TSHR-Abs.
Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki
2013-06-07
This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.
A highly sensitive and selective diagnostic assay based on virus nanoparticles
NASA Astrophysics Data System (ADS)
Park, Jin-Seung; Cho, Moon Kyu; Lee, Eun Jung; Ahn, Keum-Young; Lee, Kyung Eun; Jung, Jae Hun; Cho, Yunjung; Han, Sung-Sik; Kim, Young Keun; Lee, Jeewon
2009-04-01
Early detection of the protein marker troponin I in patients with a higher risk of acute myocardial infarction can reduce the risk of death from heart attacks. Most troponin assays are currently based on the conventional enzyme linked immunosorbent assay and have detection limits in the nano- and picomolar range. Here, we show that by combining viral nanoparticles, which are engineered to have dual affinity for troponin antibodies and nickel, with three-dimensional nanostructures including nickel nanohairs, we can detect troponin levels in human serum samples that are six to seven orders of magnitude lower than those detectable using conventional enzyme linked immunosorbent assays. The viral nanoparticle helps to orient the antibodies for maximum capture of the troponin markers. High densities of antibodies on the surfaces of the nanoparticles and nanohairs lead to greater binding of the troponin markers, which significantly enhances detection sensitivities. The nickel nanohairs are re-useable and can reproducibly differentiate healthy serum from unhealthy ones. We expect other viral nanoparticles to form similar highly sensitive diagnostic assays for a variety of other protein markers.
Fluorescence-based assay as a new screening tool for toxic chemicals
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-01-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients. PMID:27653274
Fluorescence-based assay as a new screening tool for toxic chemicals.
Moczko, Ewa; Mirkes, Evgeny M; Cáceres, César; Gorban, Alexander N; Piletsky, Sergey
2016-09-22
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Fluorescence-based assay as a new screening tool for toxic chemicals
NASA Astrophysics Data System (ADS)
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-09-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.
2001-01-01
To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995
Highly sensitive troponin T for risk stratification of acutely destabilized heart failure.
Pascual-Figal, Domingo A; Casas, Teresa; Ordonez-Llanos, Jordi; Manzano-Fernández, Sergio; Bonaque, Juan C; Boronat, Miguel; Muñoz-Esparza, Carmen; Valdés, Mariano; Januzzi, James L
2012-06-01
A highly sensitive assay for troponin T (hsTnT) has been recently developed, which allows for the detection of even minor myocardial necrosis with high precision. It remains unexplored whether hsTnT provides incremental prognostic accuracy beyond conventional (c)TnT in patients with acutely decompensated heart failure (ADHF). A total of 202 consecutive patients admitted with ADHF and without criteria for acute myocardial infarction were studied. Troponin T was measured using the highly sensitive assay and compared with the conventional method. Patients were clinically followed up at a median of 406 days, with a primary outcome measure of all-cause mortality. The high-sensitive assay detected measurable TnT in 98% of patients vs 56% for cTnT; 81% had an hsTnT above the 99th percentile for a healthy reference population, and it reclassified 60% of those with undetectable cTnT. Both TnT methods predicted the risk of death in adjusted multivariable Cox regression analyses, without a superiority of hsTnT over cTnT in the entire population (area under the curve 0.67 vs 0.71, P = .2). Among patients with a cTnT below 0.03 ng/mL (the lowest cut-point with <10% imprecision; n = 134), solely hsTnT improved the prediction of death over clinical risk factors (relative integrated discrimination improvement +36%, P = .01) and hsTnT above 20 pg/mL identified a significant higher risk of death (hazard ratio 4.7, 95% CI 1.6-13.8, P = .005). Among patients with ADHF, myocardial necrosis (as detected with the hsTnT assay) was nearly ubiquitous. The highly sensitive assay for TnT provides comparable prognostic information to cTnT overall, but among those in whom the cTnT method was less precise or frankly negative, the hsTnT assay provided prognostic information. Copyright © 2012 Mosby, Inc. All rights reserved.
Use of the HPV MLPA assay in cervical cytology for the prediction of high grade lesions.
Litjens, Rogier J N T M; Theelen, Wendy; van de Pas, Yvonne; Ossel, Jessica; Reijans, Martin; Simons, Guus; Speel, Ernst-Jan M; Slangen, Brigitte F M; Ramaekers, Frans C S; Kruitwagen, Roy F P M; Hopman, Anton H N
2013-08-01
Current screening methods for uterine cervical cancer such as Papanicolaou smears and/or high risk human Papillomavirus (HR-HPV) detection have a high negative predictive value but a low positive predictive value for the presence of high grade cervical lesions. Therefore, new parameters are needed to reduce the rate of unnecessary referrals for colposcopy. The predictive value of the HPV multiplex ligation-dependent probe amplification (MLPA) assay, which can assess simultaneously HPV16/18 viral load and viral integration, was evaluated. The assay was applied to 170 cervical cytological samples, and the results were correlated with the matching histological follow-up. The GP5+/6+ assay and qPCR were used as a control for HR-HPV typing. The MLPA assay classified a higher percentage of cases as high-risk (high-viral load and/or viral integration) with higher grades of dysplasia. There was a high correlation between the HPV MLPA assay and qPCR for viral load and HPV genotyping, and between the MLPA assay and the GP5+/6+ assay for HPV genotyping. The sensitivity and specificity of the HPV MLPA assay for the detection of high-grade lesions were 44% and 93%, respectively. This study demonstrates that the HPV MLPA assay can reliably detect HPV 16/18, viral load, and viral integration in cytological samples. Also, high-risk classification correlated well with the presence of high-grade dysplasia. However, for the implementation of the MLPA assay into clinical practice, additional HR-HPV types need to be included to increase the sensitivity of the assay, and thereby increase its negative predictive value. Copyright © 2013 Wiley Periodicals, Inc.
Kobayashi, Tsuneo
2018-03-01
Diagnosis using a specific tumor marker is difficult because the sensitivity of this detection method is under 20%. Herein, a tumor marker combination assay, combining growth-related tumor marker and associated tumor marker (Cancer, 73(7), 1994), was employed. This double-blind tumor marker combination assay (TMCA) showed 87.5% sensitivity as the results, but a low specificity, ranging from 30 to 76%. To overcome this low specificity, we exploited complex markers, a multivariate analysis and serum fractionation by biochemical biopsy. Thus, in this study, a combination of new techniques was used to re-evaluate these serum samples. Three serum panels, containing 90, 120, and 97 samples were obtained from the Mayo Clinic. The final results showed 80-90% sensitivity, 84-85% specificity, and 83-88% accuracy. We demonstrated a notable tumor marker combination assay with high accuracy. This TMCA should be applicable for primary cancer detection and recurrence prevention. © 2018 The Author. Cancer Medicine published by John Wiley & Sons Ltd.
Venkatesan, G; Balamurugan, V; Bhanuprakash, V; Singh, R K; Pandey, A B
2016-06-01
A Loop-mediated isothermal amplification (LAMP) assay targeting the highly conserved DNA polymerase gene of capripox virus genome was developed and evaluated for rapid detection of sheep pox and goat pox viruses. The optimized LAMP assay is found specific and sensitive for amplification of target DNA with a diagnostic sensitivity and specificity of 96.6% and 100% respectively compared to quantitative PCR. The detection rate of LAMP, PCR and Q-PCR assays is found to be 81.5%, 67% and 83% respectively. This LAMP assay has the potential for rapid clinical diagnosis and surveillance of sheep pox and goat pox in field diagnostic laboratories. Copyright © 2016 Elsevier Ltd. All rights reserved.
Niu, Peihua; Qi, Shunxiang; Yu, Benzhang; Zhang, Chen; Wang, Ji; Li, Qi; Ma, Xuejun
2016-11-01
Enterovirus 71 (EV71) is one of the major causative agents of outbreaks of hand, foot, and mouth disease (HFMD). A commercial TaqMan probe-based real-time PCR assay has been widely used for the differential detection of EV71 despite its relatively high cost and failure to detect samples with a low viral load (Ct value > 35). In this study, a highly sensitive real-time nested RT-PCR (RTN RT-PCR) assay in a single closed tube for detection of EV71 in HFMD was developed. The sensitivity and specificity of this assay were evaluated using a reference EV71 stock and a panel of controls consisting of coxsackievirus A16 (CVA16) and common respiratory viruses, respectively. The clinical performance of this assay was evaluated and compared with those of a commercial TaqMan probe-based real-time PCR (qRT-PCR) assay and a traditional two-step nested RT-PCR assay. The limit of detection for the RTN RT-PCR assay was 0.01 TCID50/ml, with a Ct value of 38.3, which was the same as that of the traditional two-step nested RT-PCR assay and approximately tenfold lower than that of the qRT-PCR assay. When testing the reference strain EV71, this assay showed favorable detection reproducibility and no obvious cross-reactivity. The testing results of 100 clinical throat swabs from HFMD-suspected patients revealed that 41 samples were positive for EV71 by both RTN RT-PCR and traditional two-step nested RT-PCR assays, whereas only 29 were EV71 positive by qRT-PCR assay.
Methylation-Sensitive High Resolution Melting (MS-HRM).
Hussmann, Dianna; Hansen, Lise Lotte
2018-01-01
Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.
Highly sensitive detection of target molecules using a new fluorescence-based bead assay
NASA Astrophysics Data System (ADS)
Scheffler, Silvia; Strauß, Denis; Sauer, Markus
2007-07-01
Development of immunoassays with improved sensitivity, specificity and reliability are of major interest in modern bioanalytical research. We describe the development of a new immunomagnetic fluorescence detection (IM-FD) assay based on specific antigen/antibody interactions and on accumulation of the fluorescence signal on superparamagnetic PE beads in combination with the use of extrinsic fluorescent labels. IM-FD can be easily modified by varying the order of coatings and assay conditions. Depending on the target molecule, antibodies (ABs), entire proteins, or small protein epitopes can be used as capture molecules. The presence of target molecules is detected by fluorescence microscopy using fluorescently labeled secondary or detection antibodies. Here, we demonstrate the potential of the new assay detecting the two tumor markers IGF-I and p53 antibodies in the clinically relevant concentration range. Our data show that the fluorescence-based bead assay exhibits a large dynamic range and a high sensitivity down to the subpicomolar level.
A novel and sensitive radioreceptor assay for serum melatonin levels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tenn, C.; Niles, L.
A simple and sensitive radioreceptor assay (RRA) has been developed to measure melatonin levels in serum. The assay is based on competition between 2-({sup 125}I)iodomelatonin (({sup 125}I)MEL) and melatonin for binding to high-affinity binding sites in chick forebrain. To measure the amount of melatonin present in a serum sample, it was extracted with dichloromethane and added to the assay medium. The percentage inhibition of radioligand binding in the presence of the extracted serum was determined and compared to the percent displacement by known amounts of melatonin in a standard curve. There was little or no cross-reactivity with other structurally relatedmore » compounds. The sensitivity of the assay is {approximately}1.5pg/0.15 mL and the intra- and inter-assay variations are approximately 8%. Since the RRA results are comparable to that of an established radioimmunoassay (RIA), it provides a sensitive and rapid alternative to the more time consuming RIA.« less
NASA Astrophysics Data System (ADS)
Xiong, Yanmei; Zhang, Yuyan; Rong, Pengfei; Yang, Jie; Wang, Wei; Liu, Dingbin
2015-09-01
We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose.We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose. Electronic supplementary information (ESI) available: Experimental section and additional figures. See DOI: 10.1039/c5nr03758a
Hofmann, Natalie; Mwingira, Felista; Shekalaghe, Seif; Robinson, Leanne J.; Mueller, Ivo; Felger, Ingrid
2015-01-01
Background Planning and evaluating malaria control strategies relies on accurate definition of parasite prevalence in the population. A large proportion of asymptomatic parasite infections can only be identified by surveillance with molecular methods, yet these infections also contribute to onward transmission to mosquitoes. The sensitivity of molecular detection by PCR is limited by the abundance of the target sequence in a DNA sample; thus, detection becomes imperfect at low densities. We aimed to increase PCR diagnostic sensitivity by targeting multi-copy genomic sequences for reliable detection of low-density infections, and investigated the impact of these PCR assays on community prevalence data. Methods and Findings Two quantitative PCR (qPCR) assays were developed for ultra-sensitive detection of Plasmodium falciparum, targeting the high-copy telomere-associated repetitive element 2 (TARE-2, ∼250 copies/genome) and the var gene acidic terminal sequence (varATS, 59 copies/genome). Our assays reached a limit of detection of 0.03 to 0.15 parasites/μl blood and were 10× more sensitive than standard 18S rRNA qPCR. In a population cross-sectional study in Tanzania, 295/498 samples tested positive using ultra-sensitive assays. Light microscopy missed 169 infections (57%). 18S rRNA qPCR failed to identify 48 infections (16%), of which 40% carried gametocytes detected by pfs25 quantitative reverse-transcription PCR. To judge the suitability of the TARE-2 and varATS assays for high-throughput screens, their performance was tested on sample pools. Both ultra-sensitive assays correctly detected all pools containing one low-density P. falciparum–positive sample, which went undetected by 18S rRNA qPCR, among nine negatives. TARE-2 and varATS qPCRs improve estimates of prevalence rates, yet other infections might still remain undetected when absent in the limited blood volume sampled. Conclusions Measured malaria prevalence in communities is largely determined by the sensitivity of the diagnostic tool used. Even when applying standard molecular diagnostics, prevalence in our study population was underestimated by 8% compared to the new assays. Our findings highlight the need for highly sensitive tools such as TARE-2 and varATS qPCR in community surveillance and for monitoring interventions to better describe malaria epidemiology and inform malaria elimination efforts. PMID:25734259
Evaluation of the GARD assay in a blind Cosmetics Europe study.
Johansson, Henrik; Gradin, Robin; Forreryd, Andy; Agemark, Maria; Zeller, Kathrin; Johansson, Angelica; Larne, Olivia; van Vliet, Erwin; Borrebaeck, Carl; Lindstedt, Malin
2017-01-01
Chemical hypersensitivity is an immunological response towards foreign substances, commonly referred to as sensitizers, which gives rise primarily to the clinical symptoms known as allergic contact dermatitis. For the purpose of mitigating risks associated with consumer products, chemicals are screened for sensitizing effects. Historically, such predictive screenings have been performed using animal models. However, due to industrial and regulatory demand, animal models for the purpose of sensitization assessment are being replaced by non-animal testing methods, a global trend that is spreading across industries and market segments. To meet this demand, the Genomic Allergen Rapid Detection (GARD) assay was developed. GARD is a novel, cell-based assay that utilizes the innate recognition of xenobiotic substances by dendritic cells, as measured by a multivariate readout of genomic biomarkers. Following cellular stimulation, chemicals are classified as sensitizers or non-sensitizers based on induced transcriptional profiles. Recently, a number of non-animal methods were comparatively evaluated by Cosmetics Europe, using a coherent and blinded test panel of reference chemicals with human and local lymph node assay data, comprising a wide range of sensitizers and non-sensitizers. The outcome of the GARD assay is presented in this paper. It was demonstrated that GARD is a highly functional assay with a predictive performance of 83% in this Cosmetics Europe dataset. The average accumulated predictive accuracy of GARD across independent datasets was 86% for skin sensitization hazard.
Zhu, Hong; Jia, Zhenquan; Trush, Michael A; Li, Y Robert
2016-05-01
Hydrogen peroxide (H 2 O 2 ) is a major reactive oxygen species (ROS) produced by various cellular sources, especially mitochondria. At high levels, H 2 O 2 causes oxidative stress, leading to cell injury, whereas at low concentrations, this ROS acts as an important second messenger to participate in cellular redox signaling. Detection and measurement of the levels or rates of production of cellular H 2 O 2 are instrumental in studying the biological effects of this major ROS. While a number of assays have been developed over the past decades for detecting and/or quantifying biological H 2 O 2 formation, none has been shown to be perfect. Perhaps there is no perfect assay for sensitively and accurately quantifying H 2 O 2 as well as other ROS in cells, wherein numerous potential reactants are present to interfere with the reliable measurement of the specific ROS. In this context, each assay has its own advantages and intrinsic limitations. This article describes a highly sensitive assay for real-time detection of H 2 O 2 formation in cultured cells and isolated mitochondria. This assay is based on the luminol/horseradish peroxidase-dependent chemiluminescence that is inhibitable by catalase. The article discusses the usefulness and shortcomings of this chemiluminometric assay in detecting biological H 2 O 2 formation induced by beta-lapachone redox cycling with both cells and isolated mitochondria.
Development of a PCR Assay for the Detection of Spironucleus muris
Jackson, Glenn A; Livingston, Robert S; Riley, Lela K; Livingston, Beth A; Franklin, Craig L
2013-01-01
Spironucleus muris is a protozoan that can colonize the intestinal tract of many rodent species. Although its effects on animal health and research are debated, S. muris is often included on exclusion lists for rodent facilities. Common diagnostic tests for S. muris are insensitive and typically are performed at postmortem examination. We sought to develop a PCR-based diagnostic test with sufficient sensitivity and specificity for use on fecal samples from live rodents. We designed and optimized a PCR assay that targeted the 16S-like rRNA gene of S. muris. The assay was highly specific, given that samples from mice contaminated with S. muris were PCR positive, whereas samples from mice contaminated with other protozoa were negative. The assay also was highly sensitive, detecting as few as 5 template copies per microliter diluent. All mice positive for S. muris on postmortem exams also were positive by fecal PCR. Moreover, S. muris was detected by PCR in mice negative by postmortem examination but from colonies known to be contaminated as well as in rats and hamsters. To assess protozoal loads in mice of differing ages, the PCR assay was adapted to a quantitative format. Fecal loads of S. muris were highest in 4-wk-old mice and declined with age. The PCR assay developed promises to be a highly specific antemortem diagnostic assay with higher sensitivity than that of existing postmortem tests. PMID:23562099
Harrill, Joshua A; Freudenrich, Theresa; Wallace, Kathleen; Ball, Kenneth; Shafer, Timothy J; Mundy, William R
2018-04-05
Medium- to high-throughput in vitro assays that recapitulate the critical processes of nervous system development have been proposed as a means to facilitate rapid testing and identification of chemicals which may affect brain development. In vivo neurodevelopment is a complex progression of distinct cellular processes. Therefore, batteries of in vitro assays that model and quantify effects on a variety of neurodevelopmental processes have the potential to identify chemicals which may affect brain development at different developmental stages. In the present study, the results of concentration-response screening of 67 reference chemicals in a battery of high content imaging and microplate reader-based assays that evaluate neural progenitor cell proliferation, neural proginitor cell apoptosis, neurite initiation/outgrowth, neurite maturation and synaptogenesis are summarized and compared. The assay battery had a high degree of combined sensitivity (87%) for categorizing chemicals known to affect neurodevelopment as active and a moderate degree of combined specificity (71%) for categorizing chemicals not associated with affects on neurodevelopment as inactive. The combined sensitivity of the assay battery was higher compared to any individual assay while the combined specificity of the assay battery was lower compared to any individual assay. When selectivity of effects for a neurodevelopmental endpoint as compared to general cytotoxicity was taken into account, the combined sensitivity of the assay battery decreased (68%) while the combined specificity increased (93%). The identity and potency of chemicals identified as active varied across the assay battery, underscoring the need for use of a combination of diverse in vitro models to comprehensively screen chemicals and identify those which potentially affect neurodevelopment. Overall, these data indicate that a battery of assays which address many different processes in nervous system development may be used to identify potential developmental neurotoxicants and to distinguish specific from generalized cytotoxic effects with a high degree of success. Published by Elsevier Inc.
Immunogenicity testing of therapeutic antibodies in ocular fluids after intravitreal injection.
Wessels, Uwe; Zadak, Markus; Reiser, Astrid; Brockhaus, Janis; Ritter, Mirko; Abdolzade-Bavil, Afsaneh; Heinrich, Julia; Stubenrauch, Kay
2018-04-11
High drug concentrations in ocular fluids after intravitreal administration preclude the use of drug-sensitive immunoassays. A drug-tolerant immunoassay is therefore desirable for immunogenicity testing in ophthalmology. Immune complex (IC) antidrug antibody (ADA) assays were established for two species. The assays were compared with the bridging assay in ocular and plasma samples from two preclinical studies. The IC assays showed high drug tolerance, which enabled a reliable ADA detection in ocular fluids after intravitreal administration. The IC assays were superior to the bridging assay in the analysis of ocular fluids with high drug concentrations. The IC assay allows a reliable ADA detection in matrices with high drug concentrations, such as ocular fluids.
Patel, Parag C; Hill, Douglas A; Ayers, Colby R; Lavingia, Bhavna; Kaiser, Patricia; Dyer, Adrian K; Barnes, Aliessa P; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Stastny, Peter; Ring, W Steves; de Lemos, James A; Drazner, Mark H
2014-05-01
A noninvasive biomarker that could accurately diagnose acute rejection (AR) in heart transplant recipients could obviate the need for surveillance endomyocardial biopsies. We assessed the performance metrics of a novel high-sensitivity cardiac troponin I (cTnI) assay for this purpose. Stored serum samples were retrospectively matched to endomyocardial biopsies in 98 cardiac transplant recipients, who survived ≥3 months after transplant. AR was defined as International Society for Heart and Lung Transplantation grade 2R or higher cellular rejection, acellular rejection, or allograft dysfunction of uncertain pathogenesis, leading to treatment for presumed rejection. cTnI was measured with a high-sensitivity assay (Abbott Diagnostics, Abbott Park, IL). Cross-sectional analyses determined the association of cTnI concentrations with rejection and International Society for Heart and Lung Transplantation grade and the performance metrics of cTnI for the detection of AR. Among 98 subjects, 37% had ≥1 rejection episode. cTnI was measured in 418 serum samples, including 35 paired to a rejection episode. cTnI concentrations were significantly higher in rejection versus nonrejection samples (median, 57.1 versus 10.2 ng/L; P<0.0001) and increased in a graded manner with higher biopsy scores (P(trend)<0.0001). The c-statistic to discriminate AR was 0.82 (95% confidence interval, 0.76-0.88). Using a cut point of 15 ng/L, sensitivity was 94%, specificity 60%, positive predictive value 18%, and negative predictive value 99%. A high-sensitivity cTnI assay seems useful to rule out AR in cardiac transplant recipients. If validated in prospective studies, a strategy of serial monitoring with a high-sensitivity cTnI assay may offer a low-cost noninvasive strategy for rejection surveillance. © 2014 American Heart Association, Inc.
Shen, Yong; Gong, Jiaomei; He, Yanxia; Cheng, Guomei; Okunieff, Paul; Li, Xiaofu
2013-02-01
Human papillomavirus (HPV) infection is the primary cause of cervical cancer. The Quantivirus(®) HPV E6/E7 RNA 3.0 assay (DiaCarta, CA, USA) detects E6/E7 mRNA of 13 high risk subtypes and 6 low risk subtypes. Cervical specimens collected in PreservCyt were processed for HPV detection. Cervical biopsies were taken only from those women with abnormal colposcopy. 200 out of 272 (73.5%) cases were mRNA positive. The percentage of HPV E6/E7 mRNA positive samples increases with the severity of the cytological diagnosis, but not in histological diagnosis. In 146 patients with both tests, the E6/E7 mRNA assay had significant higher positivity rate than the Hybrid Capture 2 assay (75.3% versus 62.3%). The HPV mRNA assay and the HC2 assay had the same sensitivity of high grade cervical intraepithelial neoplasia (CIN 2+), 82.4% (14/17) (95% confidence interval [CI], 64.3, 100). However, the specificity of CIN 2+ for the HPV mRNA assay was significantly lower than HC2 assay. Receiver operating characteristic curve analysis was used to compare the diagnostic performance of the E6/E7 mRNA and HC2. E6/E7 mRNA achieved 58.8% sensitivity with 74.1% specificity, HC2, achieved 47.1% sensitivity with 70.7% specificity. The overall performance of HPV E6/E7 mRNA assay for detecting CIN 2+ was lower than HC2. This study does not support the use of this assay in screening for cervical cancer prevention alone. Copyright © 2012 Elsevier B.V. All rights reserved.
Theodore, M. Jordan; Mair, Raydel; Trujillo-Lopez, Elizabeth; du Plessis, Mignon; Wolter, Nicole; Baughman, Andrew L.; Hatcher, Cynthia; Vuong, Jeni; Lott, Lisa; von Gottberg, Anne; Sacchi, Claudio; McDonald, J. Matthew; Messonnier, Nancy E.; Mayer, Leonard W.
2012-01-01
Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae are important causes of meningitis and other infections, and rapid, sensitive, and specific laboratory assays are critical for effective public health interventions. Singleplex real-time PCR assays have been developed to detect N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA and serogroup-specific genes in the cap locus for N. meningitidis serogroups A, B, C, W135, X, and Y. However, the assay sensitivity for serogroups B, W135, and Y is low. We aimed to improve assay sensitivity and develop multiplex assays to reduce time and cost. New singleplex real-time PCR assays for serogroup B synD, W135 synG, and Y synF showed 100% specificity for detecting N. meningitidis species, with high sensitivity (serogroup B synD, 99% [75/76]; W135 synG, 97% [38/39]; and Y synF, 100% [66/66]). The lower limits of detection (LLD) were 9, 43, and 10 copies/reaction for serogroup B synD, W135 synG, and Y synF assays, respectively, a significant improvement compared to results for the previous singleplex assays. We developed three multiplex real-time PCR assays for detection of (i) N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA (NHS assay); (ii) N. meningitidis serogroups A, W135, and X (AWX assay); and (iii) N. meningitidis serogroups B, C, and Y (BCY assay). Each multiplex assay was 100% specific for detecting its target organisms or serogroups, and the LLD was similar to that for the singleplex assay. Pairwise comparison of real-time PCR between multiplex and singleplex assays showed that cycle threshold values of the multiplex assay were similar to those for the singleplex assay. There were no substantial differences in sensitivity and specificity between these multiplex and singleplex real-time PCR assays. PMID:22170919
Wang, Xin; Theodore, M Jordan; Mair, Raydel; Trujillo-Lopez, Elizabeth; du Plessis, Mignon; Wolter, Nicole; Baughman, Andrew L; Hatcher, Cynthia; Vuong, Jeni; Lott, Lisa; von Gottberg, Anne; Sacchi, Claudio; McDonald, J Matthew; Messonnier, Nancy E; Mayer, Leonard W
2012-03-01
Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae are important causes of meningitis and other infections, and rapid, sensitive, and specific laboratory assays are critical for effective public health interventions. Singleplex real-time PCR assays have been developed to detect N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA and serogroup-specific genes in the cap locus for N. meningitidis serogroups A, B, C, W135, X, and Y. However, the assay sensitivity for serogroups B, W135, and Y is low. We aimed to improve assay sensitivity and develop multiplex assays to reduce time and cost. New singleplex real-time PCR assays for serogroup B synD, W135 synG, and Y synF showed 100% specificity for detecting N. meningitidis species, with high sensitivity (serogroup B synD, 99% [75/76]; W135 synG, 97% [38/39]; and Y synF, 100% [66/66]). The lower limits of detection (LLD) were 9, 43, and 10 copies/reaction for serogroup B synD, W135 synG, and Y synF assays, respectively, a significant improvement compared to results for the previous singleplex assays. We developed three multiplex real-time PCR assays for detection of (i) N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA (NHS assay); (ii) N. meningitidis serogroups A, W135, and X (AWX assay); and (iii) N. meningitidis serogroups B, C, and Y (BCY assay). Each multiplex assay was 100% specific for detecting its target organisms or serogroups, and the LLD was similar to that for the singleplex assay. Pairwise comparison of real-time PCR between multiplex and singleplex assays showed that cycle threshold values of the multiplex assay were similar to those for the singleplex assay. There were no substantial differences in sensitivity and specificity between these multiplex and singleplex real-time PCR assays.
Rapid and sensitive detection of mink circovirus by recombinase polymerase amplification.
Ge, Junwei; Shi, Yunjia; Cui, Xingyang; Gu, Shanshan; Zhao, Lili; Chen, Hongyan
2018-06-01
To date, the pathogenic role of mink circovirus (MiCV) remains unclear, and its prevalence and economic importance are unknown. Therefore, a rapid and sensitive molecular diagnosis is necessary for disease management and epidemiological surveillance. However, only PCR methods can identify MiCV infection at present. In this study, we developed a nested PCR and established a novel recombinase polymerase amplification (RPA) assay for MiCV detection. Sensitivity analysis showed that the detection limit of nested PCR and RPA assay was 10 1 copies/reaction, and these methods were more sensitive than conventional PCR, which has a detection limit of 10 5 copies/reaction. The RPA assay had no cross-reactivity with other related viral pathogens, and amplification was completed in less than 20 min with a simple device. Further assessment of clinical samples showed that the two assays were accurate in identifying positive and negative conventional PCR samples. The detection rate of MiCV by the RPA assay in clinical samples was 38.09%, which was 97% consistent with that by the nested PCR. The developed nested PCR is a highly sensitive tool for practical use, and the RPA assay is a simple, sensitive, and potential alternative method for rapid and accurate MiCV diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Noureldin, Mohamed S; el-Ganaini, Goman A; Abou El-Enin, Ahmed M; el-Nemr, Hosam-Eldin I; Hussin, Eman M; Sultan, Doaa M
2004-08-01
Seven assays detecting serum IgM, IgG, IgG1, IgG4, IgA and salivary and fecal excretory IgA against Fasciola excretory/secretory (ES) antigens were evaluated in diagnosing fascioliasis, for cross reactivity with Schistosoma mansoni sera and for evaluation of cure of Fasciola infection after treatment. Assays detecting sera IgM, IgG1, IgG4 and IgA against Fasciola ES antigens showed 100% specificity and sensitivity. Assays detecting IgM and IgG showed 98% and 96% sensitivity and 100% and 94.6% specificity respectively. Assays detecting salivary and faecal IgA showed 92% & 96% sensitivity and 100% & 100% specificity respectively. Assays detecting IgM and IgG4 were the best in evaluation of cure and assays detecting IgG4 & IgA showed the lowest cross-reactivity with sera from S. mansoni infected patients. So, assays detecting serum IgA, IgG1 & IgG4 against Fasciola ES antigens were highly sensitive and specific for diagnosis of fascioliasis and assays detecting salivary and faecal IgA were promising and of great help in diagnosis of fascioliasis especially in epidemiologic studies.
Sreedevi, C; Hafeez, Md; Subramanyam, K V; Anand Kumar, P; Chengalva Rayulu, V
2011-04-01
A flow through assay (FTA) was developed on cellulose acetate membrane for the serodiagnosis of porcine cysticercosis using cyst fluid (CFA) and whole cyst antigens (WCA) of Taenia solium metacestode. The assay consisted of antigen of T. solium metacestode coated onto membrane, mounted on a flow-through test device to provide assay capture matrix. The optimum concentration of coating antigen was 250 ng. The protein A colloidal gold conjugate served as antigen-antibody detecting reagent. A total of 225 serum samples were tested using two antigens. Results were better with CFA (96.0% sensitivity; 96.0% specificity) compared to WCA (92.0% sensitivity; 96.0% specificity). The test was also compared with enzyme-linked immunosorbent assay. The ELISA showed 96 per cent sensitivity with both the antigens whereas; the specificity was 96 and 92 per cent with CFA and WCA respectively. The sensitivity and specificity of flow through assay agrees closely with those of the ELISA. The cross-reaction was observed in one out of eight hydatidosis positive pigs (12.5%) with CFA by both the assays. The highest diagnostic accuracy (96%) was obtained with CFA-FTA and CFA-ELISA. For its high sensitivity and sporadic cross-reactions, CFA-FTA appears to be suitable for practical use at field level without instrumentation.
van Blerk, G N; Leibach, L; Mabunda, A; Chapman, A; Louw, D
2011-01-01
A real-time PCR assay combined with a pre-enrichment step for the specific and rapid detection of Salmonella in water samples is described. Following amplification of the invA gene target, High Resolution Melt (HRM) curve analysis was used to discriminate between products formed and to positively identify invA amplification. The real-time PCR assay was evaluated for specificity and sensitivity. The assay displayed 100% specificity for Salmonella and combined with a 16-18 h non-selective pre-enrichment step, the assay proved to be highly sensitive with a detection limit of 1.0 CFU/ml for surface water samples. The detection assay also demonstrated a high intra-run and inter-run repeatability with very little variation in invA amplicon melting temperature. When applied to water samples received routinely by the laboratory, the assay showed the presence of Salmonella in particularly surface water and treated effluent samples. Using the HRM based assay, the time required for Salmonella detection was drastically shortened to less than 24 h compared to several days when using standard culturing methods. This assay provides a useful tool for routine water quality monitoring as well as for quick screening during disease outbreaks.
Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Syundou, Hiromi; Saito, Hidetsugu
2007-11-01
A HCV core antigen (Ag) detection assay system, Lumipulse Ortho HCV Ag has been developed and is commercially available in Japan with a lower detection level limit of 50 fmol/l, which is equivalent to 20 KIU/ml in PCR quantitative assay. HCV core Ag assay has an advantage of broader dynamic range compared with PCR assay, however the sensitivity is lower than PCR. We developed a novel HCV core Ag concentration method using polyethylene glycol (PEG), which can improve the sensitivity five times better than the original assay. The reproducibility was examined by consecutive five-time measurement of HCV patients serum, in which the results of HCV core Ag original and concentrated method were 56.8 +/- 8.1 fmol/l (mean +/- SD), CV 14.2% and 322.9 +/- 45.5 fmol/l CV 14.0%, respectively. The assay results of HCV negative samples in original HCV core Ag were all 0.1 fmol/l and the results were same even in the concentration method. The results of concentration method were 5.7 times higher than original assay, which was almost equal to theoretical rate as expected. The assay results of serially diluted samples were also as same as expected data in both original and concentration assay. We confirmed that the sensitivity of HCV core Ag concentration method had almost as same sensitivity as PCR high range assay in the competitive assay study using the serially monitored samples of five HCV patients during interferon therapy. A novel concentration method using PEG in HCV core Ag assay system seems to be useful for assessing and monitoring interferon treatment for HCV.
Bonnet, Romaric; Farre, Carole; Valera, Lionel; Vossier, Ludivine; Léon, Fanny; Dagland, Typhaine; Pouzet, Agnès; Jaffrézic-Renault, Nicole; Fareh, Jeannette; Fournier-Wirth, Chantal; Chaix, Carole
2018-05-15
A nanoparticle-based electrochemical sandwich immunoassay was developed for bacteria detection in platelet concentrates. For the assay, magnetic beads were functionalized with antibodies to allow the specific capture of bacteria from the complex matrix, and innovative methylene blue-DNA/nanoparticle assemblies provided the electrochemical response for amplified detection. This nanoparticular system was designed as a temperature-sensitive nano-tool for electrochemical detection. First, oligonucleotide-functionalized nanoparticles were obtained by direct synthesis of the DNA strands on the nanoparticle surface using an automated oligonucleotide synthesizer. Densely packed DNA coverage was thus obtained. Then, DNA duplexes were constructed on the NP surface with a complementary strand bearing a 3 methylene blue tag. This strategy ultimately produced highly functionalized nanoparticles with electrochemical markers. These assemblies enabled amplification of the electrochemical signal, resulting in a very good sensitivity. A proof-of-concept was carried out for E. coli detection in human platelet concentrates. Bacterial contamination of this complex biological matrix is the highest residual infectious risk in blood transfusion. The development of a rapid assay that could reach 10-102 CFU mL-1 sensitivity is a great challenge. The nanoparticle-based electrochemical sandwich immunoassay carried out on a boron doped diamond electrode proved to be sensitive for E. coli detection in human platelets. Two antibody pairs were used to develop either a generic assay against certain Gram negative strains or a specific assay for E. coli. The methylene blue-DNA/nanoparticles amplify sensitivity ×1000 compared with the assay run without NPs for electrochemical detection. A limit of detection of 10 CFU mL-1 in a biological matrix was achieved for E. coli using the highly specific antibody pair.
Long-Term Resolution of Viral Breakthrough after Changing HIV Viral Load Assay.
Obeid, Karam M; Sural, Preethi; Szpunar, Susan; Johnson, Leonard B
2011-01-01
Viral load (VL) measurement assays differ in their sensitivity with polymerase chain reaction assays (PCR) being more sensitive than branched DNA (bDNA) assays. We evaluated virologic outcomes of patients and physicians' response to increased VL after a switch from bDNA to PCR assay. Retrospective, case-control study on 65 HIV+ patients receiving highly active antiretroviral therapy (HAART). Cases included patients with undetectable VL by bDNA that became detectable after the switch; controls were patients that remained undetectable. Records were reviewed up to 1 year after the switch. A total of 58.5% patients had detectable VL after the switch. Repeat VL testing and resistance testing were ordered in 15.4% and 23.1% of these patients, respectively. By 1 year, VL was undetectable in 82.8% of cases and 92% of controls (P = .30), without change in HAART. Transient viremia after changing VL assay reflects the different sensitivity of these assays with no impact on patients' outcomes compared to controls.
Xing, Weiwei; Yu, Xinling; Feng, Jingtao; Sun, Kui; Fu, Wenliang; Wang, Yuanyuan; Zou, Minji; Xia, Wenrong; Luo, Zhihong; He, Hongbin; Li, Yuesheng; Xu, Donggang
2017-02-21
Current diagnostic methods for Schistosoma japonicum infection are insensitive for low-density infections. Therefore, a new diagnostic assay based on recombinase polymerase amplification (RPA) technology was established and assessed for field applification. The S.japonicum RPA assay was developed to target highly repetitive retrotransposon SjR2 gene of S japonicum, and its sensitivity and specificity were assessed by serial dilution of S. japonicum genomic DNA and other related worm genomic DNA respectively. The RPA diagnostic validity was first evaluated in 60 fecal samples from healthy people and patients, and then compared with other diagnostic tests in 200 high-risk individuals living in endemic areas. The real time RPA assay could detect 0.9 fg S. japonicum DNA within 15 min and distinguish S. japonicum from other worms. The validity analysis of RPA for the detection of S. japonicum in stool samples from 30 S. japonicum-infected patients and 30 healthy persons indicated 100% sensitivity and specificity. When testing 200 fecal or serum samples from a high-risk population, the percentage sensitivity of RPA was 100%, whereas that of indirect hemagglutination assay (IHA) and enzyme-linked immunosorbent assay (ELISA) were 80.3% and 85.2% respectively. In addition, the RPA presented better consistency with the stool-based tests than IHA and ELISA. Overall, the RPA was superior to other detection methods with respect to detection time, sensitivity, and convenience. This is the first time we applied the RPA technology to the field evaluation of S. japonicum infection. And the results suggest that RPA-based assays can be used as a promising point-of-care test for the diagnosis of schistosomiasis.
Balsiger, Heather A.; de la Torre, Roberto; Lee, Wen-Yee; Cox, Marc B.
2010-01-01
The assay described here represents an improved yeast bioassay that provides a rapid yet sensitive screening method for EDCs with very little hands-on time and without the need for sample preparation. Traditional receptor-mediated reporter assays in yeast were performed twelve to twenty four hours after ligand addition, used colorimetric substrates, and, in many cases, required high, non-physiological concentrations of ligand. With the advent of new chemiluminescent substrates a ligand-induced signal can be detected within thirty minutes using high picomolar to low nanomolar concentrations of estrogen. As a result of the sensitivity (EC50 for estradiol is ~ 0.7 nM) and the very short assay time (2-4 hours) environmental water samples can typically be assayed directly without sterilization, extraction, and concentration. Thus, these assays represent rapid and sensitive approaches for determining the presence of contaminants in environmental samples. As proof of principle, we directly assayed wastewater influent and effluent taken from a wastewater treatment plant in the El Paso, TX area for the presence of estrogenic activity. The data obtained in the four-hour yeast bioassay directly correlated with GC-mass spectrometry analysis of these same water samples. PMID:20074779
Taniuchi, Mami; Verweij, Jaco J.; Noor, Zannatun; Sobuz, Shihab U.; van Lieshout, Lisette; Petri, William A.; Haque, Rashidul; Houpt, Eric R.
2011-01-01
Polymerase chain reaction (PCR) assays for intestinal parasites are increasingly being used on fecal DNA samples for enhanced specificity and sensitivity of detection. Comparison of these tests against microscopy and copro-antigen detection has been favorable, and substitution of PCR-based assays for the ova and parasite stool examination is a foreseeable goal for the near future. One challenge is the diverse list of protozoan and helminth parasites. Several existing real-time PCR assays for the major intestinal parasites—Cryptosporidium spp., Giardia intestinalis, Entamoeba histolytica, Ancylostoma duodenale, Ascaris lumbricoides, Necator americanus, and Strongyloides stercoralis—were adapted into a high throughput protocol. The assay involves two multiplex PCR reactions, one with specific primers for the protozoa and one with specific primers for the helminths, after which PCR products are hybridized to beads linked to internal oligonucleotide probes and detected on a Luminex platform. When compared with the parent multiplex real-time PCR assays, this multiplex PCR-bead assay afforded between 83% and 100% sensitivity and specificity on a total of 319 clinical specimens. In conclusion, this multiplex PCR-bead protocol provides a sensitive diagnostic screen for a large panel of intestinal parasites. PMID:21292910
Geng, Yunyun; Wang, Jianchang; Liu, Libing; Lu, Yan; Tan, Ke; Chang, Yan-Zhong
2017-11-06
Canine parvovirus 2, a linear single-stranded DNA virus belonging to the genus Parvovirus within the family Parvoviridae, is a highly contagious pathogen of domestic dogs and several wild canidae species. Early detection of canine parvovirus (CPV-2) is crucial to initiating appropriate outbreak control strategies. Recombinase polymerase amplification (RPA), a novel isothermal gene amplification technique, has been developed for the molecular detection of diverse pathogens. In this study, a real-time RPA assay was developed for the detection of CPV-2 using primers and an exo probe targeting the CPV-2 nucleocapsid protein gene. The real-time RPA assay was performed successfully at 38 °C, and the results were obtained within 4-12 min for 10 5 -10 1 molecules of template DNA. The assay only detected CPV-2, and did not show cross-detection of other viral pathogens, demonstrating a high level of specificity. The analytical sensitivity of the real-time RPA was 10 1 copies/reaction of a standard DNA template, which was 10 times more sensitive than the common RPA method. The clinical sensitivity of the real-time RPA assay matched 100% (n = 91) to the real-time PCR results. The real-time RPA assay is a simple, rapid, reliable and affordable method that can potentially be applied for the detection of CPV-2 in the research laboratory and point-of-care diagnosis.
Babu, Binoy; Jeyaprakash, Ayyamperumal; Jones, Debra; Schubert, Timothy S; Baker, Carlye; Washburn, Brian K; Miller, Steven H; Poduch, Kristina; Knox, Gary W; Ochoa-Corona, Francisco M; Paret, Mathews L
2016-09-01
Rose rosette virus (RRV), belonging to the genus Emaravirus, is a highly destructive pathogen that causes rose rosette disease. The disease is a major concern for the rose industry in the U.S. due to the lack of highly sensitive methods for early detection of RRV. This is critical, as early identification of the infected plants and eradication is necessary in minimizing the risks associated with the spread of the disease. A highly reliable, specific and sensitive detection assay is thus required to test and confirm the presence of RRV in suspected plant samples. In this study a TaqMan real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was developed for the detection of RRV from infected roses, utilizing multiple gene targets. Four pairs of primers and probes; two of them (RRV_2-1 and RRV_2-2) based on the consensus sequences of the glycoprotein gene (RNA2) and the other two (RRV_3-2 and RRV_3-5) based on the nucleocapsid gene (RNA3) were designed. The specificity of the primers and probes was evaluated against other representative viruses infecting roses, belonging to the genera Alfamovirus, Cucumovirus, Ilarvirus, Nepovirus, Tobamovirus, and Tospovirus and one Emaravirus (Wheat mosaic virus). Dilution assays using the in vitro transcripts (spiked with total RNA from healthy plants, and non-spiked) showed that all the primers and probes are highly sensitive in consistently detecting RRV with a detection limit of 1 fg. Testing of the infected plants over a period of time (three times in monthly intervals) indicated high reproducibility, with the primer/probe RRV_3-5 showing 100% positive detection, while RRV_2-1, RRV_2-2 and RRV_3-2 showed 90% positive detection. The developed real-time RT-PCR assay is reliable, highly sensitive, and can be easily used in diagnostic laboratories for testing and confirmation of RRV. Copyright © 2016 Elsevier B.V. All rights reserved.
Lowering the quantification limit of the QubitTM RNA HS assay using RNA spike-in.
Li, Xin; Ben-Dov, Iddo Z; Mauro, Maurizio; Williams, Zev
2015-05-06
RNA quantification is often a prerequisite for most RNA analyses such as RNA sequencing. However, the relatively low sensitivity and large sample consumption of traditional RNA quantification methods such as UV spectrophotometry and even the much more sensitive fluorescence-based RNA quantification assays, such as the Qubit™ RNA HS Assay, are often inadequate for measuring minute levels of RNA isolated from limited cell and tissue samples and biofluids. Thus, there is a pressing need for a more sensitive method to reliably and robustly detect trace levels of RNA without interference from DNA. To improve the quantification limit of the Qubit™ RNA HS Assay, we spiked-in a known quantity of RNA to achieve the minimum reading required by the assay. Samples containing trace amounts of RNA were then added to the spike-in and measured as a reading increase over RNA spike-in baseline. We determined the accuracy and precision of reading increases between 1 and 20 pg/μL as well as RNA-specificity in this range, and compared to those of RiboGreen(®), another sensitive fluorescence-based RNA quantification assay. We then applied Qubit™ Assay with RNA spike-in to quantify plasma RNA samples. RNA spike-in improved the quantification limit of the Qubit™ RNA HS Assay 5-fold, from 25 pg/μL down to 5 pg/μL while maintaining high specificity to RNA. This enabled quantification of RNA with original concentration as low as 55.6 pg/μL compared to 250 pg/μL for the standard assay and decreased sample consumption from 5 to 1 ng. Plasma RNA samples that were not measurable by the Qubit™ RNA HS Assay were measurable by our modified method. The Qubit™ RNA HS Assay with RNA spike-in is able to quantify RNA with high specificity at 5-fold lower concentration and uses 5-fold less sample quantity than the standard Qubit™ Assay.
Rahman, S. M. Mazidur; Song, Hyun Beom; Jin, Yan; Oh, Jin-Kyoung; Lim, Min Kyung; Hong, Sung-Tae
2017-01-01
Background Clonorchiasis is prevalent in the Far East, and a major health problem in endemic areas. Infected persons may experience, if not treated, serious complications such as bile stone formation, pyogenic cholangitis, and even cholangiocarcinoma. Early diagnosis and treatment are important to prevent serious complications and, therefore, the simple and reliable diagnostic method is necessary to control clonorchiasis in endemic areas, where resources for the diagnosis are limited. Methodology/Principle findings The loop-mediated isothermal amplification (LAMP) assay has been applied for the detection of Clonorchis sinensis DNA. Six primers targeting eight locations on the cytochrome c oxidase subunit 1 gene of C. sinensis were designed for species-specific amplification using the LAMP assay. The LAMP assay was sensitive enough to detect as little as 100 fg of C. sinensis genomic DNA and the detection limit in 100 mg of stool was as low as one egg. The assay was highly specific because no cross-reactivity was observed with the DNA of other helminths, protozoa or Escherichia coli. Then, LAMP assay was applied to human fecal samples collected from an endemic area of clonorchiasis in Korea. Using samples showing consistent results by both Kato-Katz method and real-time PCR as reference standards, the LAMP assay showed 97.1% (95% CI, 90.1–99.2) of sensitivity and 100% (95% CI, 92.9–100) of specificity. In stool samples with more than 100 eggs per gram of feces, the sensitivity achieved 100%. Conclusions To detect C. sinensis in human fecal samples, the LAMP assay was applied and achieved high sensitivity and specificity. The LAMP assay can be utilized in field laboratories as a powerful tool for diagnosis and epidemiological survey of clonorchiasis. PMID:28991924
Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David
2017-01-01
Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.
Rahman, S M Mazidur; Song, Hyun Beom; Jin, Yan; Oh, Jin-Kyoung; Lim, Min Kyung; Hong, Sung-Tae; Choi, Min-Ho
2017-10-01
Clonorchiasis is prevalent in the Far East, and a major health problem in endemic areas. Infected persons may experience, if not treated, serious complications such as bile stone formation, pyogenic cholangitis, and even cholangiocarcinoma. Early diagnosis and treatment are important to prevent serious complications and, therefore, the simple and reliable diagnostic method is necessary to control clonorchiasis in endemic areas, where resources for the diagnosis are limited. The loop-mediated isothermal amplification (LAMP) assay has been applied for the detection of Clonorchis sinensis DNA. Six primers targeting eight locations on the cytochrome c oxidase subunit 1 gene of C. sinensis were designed for species-specific amplification using the LAMP assay. The LAMP assay was sensitive enough to detect as little as 100 fg of C. sinensis genomic DNA and the detection limit in 100 mg of stool was as low as one egg. The assay was highly specific because no cross-reactivity was observed with the DNA of other helminths, protozoa or Escherichia coli. Then, LAMP assay was applied to human fecal samples collected from an endemic area of clonorchiasis in Korea. Using samples showing consistent results by both Kato-Katz method and real-time PCR as reference standards, the LAMP assay showed 97.1% (95% CI, 90.1-99.2) of sensitivity and 100% (95% CI, 92.9-100) of specificity. In stool samples with more than 100 eggs per gram of feces, the sensitivity achieved 100%. To detect C. sinensis in human fecal samples, the LAMP assay was applied and achieved high sensitivity and specificity. The LAMP assay can be utilized in field laboratories as a powerful tool for diagnosis and epidemiological survey of clonorchiasis.
Jewett, A; Smith, B D; Garfein, R S; Cuevas-Mota, J; Teshale, E H; Weinbaum, C M
2012-07-01
Approximately 4.1 million Americans are estimated to have been infected with hepatitis C virus (HCV), 45-85% of whom are unaware of their infection. Persons who inject drugs (PWID) account for 55.8% of all persons with HCV antibody (anti-HCV) in the U.S. PWID have limited access to healthcare and are infrequently tested for anti-HCV using conventional laboratory assays. To evaluate performance characteristics (sensitivity and specificity) of three, pre-market rapid point-of-care tests (one oral fluid and two finger-stick assays) from two manufacturers (Chembio and MedMira) in settings providing services to young adult PWID in San Diego, CA. Behavioral risk assessment surveys and testing for HCV were conducted among persons who reported injection drug use (IDU) within the past 6 months as part of the Study to Assess Hepatitis C Risk (STAHR) among PWID aged 18-40 years in 2009-2010. Sensitivity and specificity of the rapid anti-HCV assays were evaluated among STAHR participants, using two commonly used testing algorithms. Variability in sensitivity (76.6-97.1%) and specificity (99.0-100.0%) was found across assays. The highest sensitivity achieved for the Chembio finger-stick blood, Chembio oral fluid and MedMira finger-stick blood tests was 97.1%, 85.4% and 80.0% respectively; the highest specificity was 99.0%, 100.0% and 100.0%, respectively. In multivariate analysis false negative anti-HCV results were associated with female sex for the MedMira blood assay. Sensitive anti-HCV rapid assays are appropriate and feasible for high-prevalence, high-risk populations such as young PWID. Copyright © 2012 Elsevier B.V. All rights reserved.
Lactobacillus farciminis MD, a newer strain with potential for bacteriocin and antibiotic assay.
Halami, P M; Chandrashekar, A; Nand, K
2000-03-01
A native isolate Lactobacillus farciminis MD isolated from fermenting mushroom exhibited a high degree of sensitivity to the majority of the bacteriocins produced by strains of lactobacilli, leuconostoc and pediococci. Also, the efficacy of Lact. farciminis MD as a sensitive strain for antibiotic assay was established against different antibiotics including ampicillin, cefazoline, chloramphenicol and nitrofurantoin at concentrations of 30 microg each, showing an inhibition zone of 30 mm diameter. The high degree of sensitivity towards bacteriocins and antibiotics provide potential for the exploitation of Lact. farciminis MD in establishing very well-defined bacteriocin producers.
Li, Zhu-Nan; Weber, Kimberly M; Limmer, Rebecca A; Horne, Bobbi J; Stevens, James; Schwerzmann, Joy; Wrammert, Jens; McCausland, Megan; Phipps, Andrew J; Hancock, Kathy; Jernigan, Daniel B; Levine, Min; Katz, Jacqueline M; Miller, Joseph D
2017-05-01
Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex ® , and ForteBio ® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections. Published by Elsevier B.V.
DNA Methyltransferase Activity Assays: Advances and Challenges
Poh, Wan Jun; Wee, Cayden Pang Pee; Gao, Zhiqiang
2016-01-01
DNA methyltransferases (MTases), a family of enzymes that catalyse the methylation of DNA, have a profound effect on gene regulation. A large body of evidence has indicated that DNA MTase is potentially a predictive biomarker closely associated with genetic disorders and genetic diseases like cancer. Given the attention bestowed onto DNA MTases in molecular biology and medicine, highly sensitive detection of DNA MTase activity is essential in determining gene regulation, epigenetic modification, clinical diagnosis and therapeutics. Conventional techniques such as isotope labelling are effective, but they often require laborious sample preparation, isotope labelling, sophisticated equipment and large amounts of DNA, rendering them unsuitable for uses at point-of-care. Simple, portable, highly sensitive and low-cost assays are urgently needed for DNA MTase activity screening. In most recent technological advances, many alternative DNA MTase activity assays such as fluorescent, electrochemical, colorimetric and chemiluminescent assays have been proposed. In addition, many of them are coupled with nanomaterials and/or enzymes to significantly enhance their sensitivity. Herein we review the progress in the development of DNA MTase activity assays with an emphasis on assay mechanism and performance with some discussion on challenges and perspectives. It is hoped that this article will provide a broad coverage of DNA MTase activity assays and their latest developments and open new perspectives toward the development of DNA MTase activity assays with much improved performance for uses in molecular biology and clinical practice. PMID:26909112
Kim, Eun-Ju; Cheong, Kwang-Myun; Joung, Ha-Kyung; Kim, Bo-Hye; Song, Jae-Young; Cho, In-Soo; Lee, Kyoung-Ki; Shin, Yeun-Kyung
2016-12-30
Infection of cattle with bovine leukemia virus (BLV) has been observed and reported worldwide, including in Korea. The onsite identification of infected cattle would help decreasing and eradicating BLV infections on farms. Here, we present a new immunochromatographic assay that employs monoclonal antibodies (MAbs) for the detection of antibodies against BLV in the field. BLV envelope glycoprotein (gp)51 was expressed in E. coli , and MAbs against recombinant BLV gp51 were generated for the development of an immunochromatographic assay to detect BLV antibodies in cattle. The sensitivity and specificity of the assay were determined by comparing these results with those obtained from a standard enzyme linked immunosorbent assay (ELISA). A total of 160 bovine sera were used to evaluate the new immunochromatographic assay. Using ELISA as a reference standard, the relative specificity and sensitivity of this assay were determined to be 94.7% and 98%, respectively. Because of its high sensitivity and specificity, this BLV antibody detection assay would be suitable for the onsite identification of BLV infection in the field.
Highly sensitive bacterial susceptibility test against penicillin using parylene-matrix chip.
Park, Jong-Min; Kim, Jo-Il; Song, Hyun-Woo; Noh, Joo-Yoon; Kang, Min-Jung; Pyun, Jae-Chul
2015-09-15
This work presented a highly sensitive bacterial antibiotic susceptibility test through β-lactamase assay using Parylene-matrix chip. β-lactamases (EC 3.5.2.6) are an important family of enzymes that confer resistance to β-lactam antibiotics by catalyzing the hydrolysis of these antibiotics. Here we present a highly sensitive assay to quantitate β-lactamase-mediated hydrolysis of penicillin into penicilloic acid. Typically, MALDI-TOF mass spectrometry has been used to quantitate low molecular weight analytes and to discriminate them from noise peaks of matrix fragments that occur at low m/z ratios (m/z<500). The β-lactamase assay for the Escherichia coli antibiotic susceptibility test was carried out using Parylene-matrix chip and MALDI-TOF mass spectrometry. The Parylene-matrix chip was successfully used to quantitate penicillin (m/z: [PEN+H](+)=335.1 and [PEN+Na](+)=357.8) and penicilloic acid (m/z: [PA+H](+)=353.1) in a β-lactamase assay with minimal interference of low molecular weight noise peaks. The β-lactamase assay was carried out with an antibiotic-resistant E. coli strain and an antibiotic-susceptible E. coli strain, revealing that the minimum number of E. coli cells required to screen for antibiotic resistance was 1000 cells for the MALDI-TOF mass spectrometry/Parylene-matrix chip assay. Copyright © 2015 Elsevier B.V. All rights reserved.
Li, Dongdong; An, Jingna; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan
2016-11-01
The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys ® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study. In comparison with InTec assay, the Elecsys ® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay. There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys ® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay. Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys ® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys ® Syphilis assay is applied to patients with malignant neoplasm or HIV infection. © 2016 Wiley Periodicals, Inc.
A high-throughput multiplex method adapted for GMO detection.
Chaouachi, Maher; Chupeau, Gaëlle; Berard, Aurélie; McKhann, Heather; Romaniuk, Marcel; Giancola, Sandra; Laval, Valérie; Bertheau, Yves; Brunel, Dominique
2008-12-24
A high-throughput multiplex assay for the detection of genetically modified organisms (GMO) was developed on the basis of the existing SNPlex method designed for SNP genotyping. This SNPlex assay allows the simultaneous detection of up to 48 short DNA sequences (approximately 70 bp; "signature sequences") from taxa endogenous reference genes, from GMO constructions, screening targets, construct-specific, and event-specific targets, and finally from donor organisms. This assay avoids certain shortcomings of multiplex PCR-based methods already in widespread use for GMO detection. The assay demonstrated high specificity and sensitivity. The results suggest that this assay is reliable, flexible, and cost- and time-effective for high-throughput GMO detection.
Quinn, Andrea M; Williams, Allison R; Sivilli, Teresa I; Raison, Charles L; Pace, Thaddeus W W
2018-03-13
Circulating concentrations of interleukin (IL)-6, an inflammatory biomarker widely assessed in humans to study the inflammatory response to acute psychological stress, have for decades been quantified using enzyme-linked immunosorbent assay (ELISA). However, biobehavioral researchers are increasingly using cytokine multiplex assays instead of ELISA to measure IL-6 and other cytokines. Despite this trend, multiplex assays have not been directly compared to ELISA for their ability to detect subtle stress-induced changes of IL-6. Here, we tested the prediction that a high-sensitivity multiplex assay (human Magnetic Luminex Performance Assay, R&D Systems, Minneapolis, MN) would detect changes in IL-6 as a result of acute stress challenge in a manner comparable to high-sensitivity ELISA. Blood was collected from 12 healthy adults immediately before and then 90 and 210 min after the start of the Trier Social Stress Test (TSST), an acute laboratory psychosocial stress challenge. In addition to quantifying IL-6 concentrations in plasma with both multiplex and ELISA, we also assessed concentrations of tumor necrosis factor-alpha, IL-8, IL-10, IL-5, and IL-2 with multiplex. The multiplex detected IL-6 in all samples. Concentrations strongly correlated with values determined by ELISA across all samples (r = 0.941, p < .001) as well as among samples collected at individual TSST time points. IL-6 responses to the TSST (i.e. area under the curve) captured by multiplex and ELISA were also strongly correlated (r s = 0.937, p < .001). While other cytokines were detected by multiplex, none changed as a result of TSST challenge at time points examined. These results suggest high-sensitivity magnetic multiplex assay is able to detect changes in plasma concentrations of IL-6 as a result of acute stress in humans.
Press, Michael F; Slamon, Dennis J; Flom, Kerry J; Park, Jinha; Zhou, Jian-Yuan; Bernstein, Leslie
2002-07-15
To compare and evaluate HER-2/neu clinical assay methods. One hundred seventeen breast cancer specimens with known HER-2/neu amplification and overexpression status were assayed with four different immunohistochemical assays and two different fluorescence in situ hybridization (FISH) assays. The accuracy of the FISH assays for HER-2/neu gene amplification was high, 97.4% for the Vysis PathVision assay (Vysis, Inc, Downers Grove, IL) and 95.7% for the the Ventana INFORM assay (Ventana, Medical Systems, Inc, Tucson, AZ). The immunohistochemical assay with the highest accuracy for HER-2/neu overexpression was obtained with R60 polyclonal antibody (96.6%), followed by immunohistochemical assays performed with 10H8 monoclonal antibody (95.7%), the Ventana CB11 monoclonal antibody (89.7%), and the DAKO HercepTest (88.9%; Dako, Corp, Carpinteria, CA). Only the sensitivities, and therefore, overall accuracy, of the DAKO Herceptest and Ventana CB11 immunohistochemical assays were significantly different from the more sensitive FISH assay. Based on these findings, the FISH assays were highly accurate, with immunohistochemical assays performed with R60 and 10H8 nearly as accurate. The DAKO HercepTest and the Ventana CB11 immunohistochemical assay were statistically significantly different from the Vysis FISH assay in evaluating these previously molecularly characterized breast cancer specimens.
Beyda, Nicholas D; Amadio, Jonathan; Rodriguez, Jose R; Malinowski, Karen; Garey, Kevin W; Wanger, Audrey; Ostrosky-Zeichner, Luis
2018-06-13
The T2Candida assay is a novel, non-culture based assay for the diagnosis of candidemia directly from whole blood. The impact of antifungals on the performance of the T2Candida assay and blood culture bottles have not been well described. In this study, the performance of the T2Candida assay was compared to that of blood culture in detecting Candida spp. in spiked blood cultures with or without the presence of antifungals. Clinical bloodstream isolates of Candida spp. were inoculated into human whole blood at low (1 - 5 cells/mL) and high (10-50 cells/mL) concentrations with or without presence of caspofungin and fluconazole. Time to detection (TTD) was assessed for prepared samples using BacTAlert FA aerobic blood culture bottles or the T2Candida assay. In the absence of antifungals, T2Candida assay sensitivity was comparable to that of blood culture at both the low and high inoculum (95% vs. 97.5% and 100% vs. 100%, respectively) and had an average TTD that was significantly faster (5.1 hrs vs 27.2 - 30 hrs, respectively). Neither caspofungin nor fluconazole was observed to impact the sensitivity or TTD of the T2Candida assay, while fluconazole reduced overall blood culture sensitivity by 7.5% - 12.5% (at low and high inoculum, respectively) and significantly prolonged the TTD of C. albicans, C. tropicalis , and C. parapsilosis by 14.8 - 67 hrs. Neither caspofungin nor fluconazole impacted the performance of the T2Candida assay in-vitro and may be useful for the diagnosis of candidemia in patients receiving antifungal therapy. Copyright © 2018 American Society for Microbiology.
Mandappa, I M; Joglekar, Prasanna; Manonmani, H K
2015-07-01
A multiplex real-time isothermal amplification assay was developed using molecular beacons for the detection of Bacillus cereus and Staphylococcus aureus by targeting four important virulence genes. A correlation between targeting highly accessible DNA sequences and isothermal amplification based molecular beacon efficiency and sensitivity was demonstrated using phi(Φ)29 DNA polymerase at a constant isothermal temperature of 30 °C. It was very selective and consistently detected down to 10(1) copies of DNA. The specificity and sensitivity of this assay, when tested with pure culture were high, surpassing those of currently used PCR assays for the detection of these organisms. The molecular beacon based real-time isothermal amplification (MBRTIA) assay could be carried out entirely in 96 well plates or well strips, enabling a rapid and high-throughput detection of food borne pathogens.
Lim, Kah Tee; Zahari, Zuriati; Amanah, Azimah; Zainuddin, Zafarina; Adenan, Mohd Ilham
2016-03-01
To accelerate the discovery of novel leads for the treatment of Human African Trypanosomiasis (HAT), it is necessary to have a simple, robust and cost-effective assay to identify positive hits by high throughput whole cell screening. Most of the fluorescence assay was made in black plate however in this study the HTS assay developed in 384-well format using clear plate and black plate, for comparison. The HTS assay developed is simple, sensitive, reliable and reproducible in both types of plates. Assay robustness and reproducibility were determined under the optimized conditions in 384-well plate was well tolerated in the HTS assay, including percentage of coefficient of variation (% CV) of 4.68% and 4.74% in clear and black 384-well plate, signal-to-background ratio (S/B) of 12.75 in clear 384-well plate and 12.07 in black 384-well plate, Z' factor of 0.79 and 0.82 in clear 384-well plate and black 384-well plate, respectively and final concentration of 0.30% dimethylsulfoxide (DMSO) in both types of plate. Drug sensitivity was found to be comparable to the reported anti-trypanosomal assay in 96-well format. The reproducibility and sensitivity of this assay make it compliant to automated liquid handler use in HTS applications. Copyright © 2016 Elsevier Inc. All rights reserved.
Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman
2016-12-15
The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.
A multiplex branched DNA assay for parallel quantitative gene expression profiling.
Flagella, Michael; Bui, Son; Zheng, Zhi; Nguyen, Cung Tuong; Zhang, Aiguo; Pastor, Larry; Ma, Yunqing; Yang, Wen; Crawford, Kimberly L; McMaster, Gary K; Witney, Frank; Luo, Yuling
2006-05-01
We describe a novel method to quantitatively measure messenger RNA (mRNA) expression of multiple genes directly from crude cell lysates and tissue homogenates without the need for RNA purification or target amplification. The multiplex branched DNA (bDNA) assay adapts the bDNA technology to the Luminex fluorescent bead-based platform through the use of cooperative hybridization, which ensures an exceptionally high degree of assay specificity. Using in vitro transcribed RNA as reference standards, we demonstrated that the assay is highly specific, with cross-reactivity less than 0.2%. We also determined that the assay detection sensitivity is 25,000 RNA transcripts with intra- and interplate coefficients of variance of less than 10% and less than 15%, respectively. Using three 10-gene panels designed to measure proinflammatory and apoptosis responses, we demonstrated sensitive and specific multiplex gene expression profiling directly from cell lysates. The gene expression change data demonstrate a high correlation coefficient (R(2)=0.94) compared with measurements obtained using the single-plex bDNA assay. Thus, the multiplex bDNA assay provides a powerful means to quantify the gene expression profile of a defined set of target genes in large sample populations.
Favaloro, E J; Bonar, R; Chapman, K; Meiring, M; Funk Adcock, D
2012-06-01
von Willebrand disease (VWD), the most common inherited bleeding disorder, is caused by deficiencies and/or defects in von Willebrand factor (VWF). An effective diagnostic and VWD typing strategy requires plasma testing for factor VIII, and VWF antigen plus one or more VWF 'activity' assays. VWF activity is classically assessed by using VWF ristocetin cofactor activity (VWF:RCo), although VWF collagen-binding (VWF:CB) and VWF mAb-based (VWF activity [VWF:Act]) assays are used by some laboratories. To perform a cross-laboratory study to specifically evaluate these three VWF activity assays for comparative sensitivity to loss of high molecular weight (HMW) VWF, representing the form of VWF that is most functionally active and that is absent in some types of VWD, namely 2A and 2B. A set of eight samples, including six selectively representing stepwise reduction in HMW VWF, were tested by 51 different laboratories using a variety of assays. The combined data showed that the VWF:CB and VWF:RCo assays had higher sensitivity to the loss of HMW VWF than did the VWF:Act assay. Moreover, within-method analysis identified better HMW VWF sensitivity of some VWF:CB assays than of others, with all VWF:CB assays still showing better sensitivity than the VWF:Act assay. Differences were also identified between VWF:RCo methodologies on the basis of either platelet aggregometry or as performed on automated analyzers. We believe that these results have significant clinical implications for the diagnosis of VWD and monitoring of its therapy, as well as for the future diagnosis and therapy monitoring of thrombotic thrombocytopenic purpura. © 2012 International Society on Thrombosis and Haemostasis.
Stubbs, Samuel; Oura, Chris A L; Henstock, Mark; Bowden, Timothy R; King, Donald P; Tuppurainen, Eeva S M
2012-02-01
Capripoxviruses, which are endemic in much of Africa and Asia, are the aetiological agents of economically devastating poxviral diseases in cattle, sheep and goats. The aim of this study was to validate a high-throughput real-time PCR assay for routine diagnostic use in a capripoxvirus reference laboratory. The performance of two previously published real-time PCR methods were compared using commercially available reagents including the amplification kits recommended in the original publication. Furthermore, both manual and robotic extraction methods used to prepare template nucleic acid were evaluated using samples collected from experimentally infected animals. The optimised assay had an analytical sensitivity of at least 63 target DNA copies per reaction, displayed a greater diagnostic sensitivity compared to conventional gel-based PCR, detected capripoxviruses isolated from outbreaks around the world and did not amplify DNA from related viruses in the genera Orthopoxvirus or Parapoxvirus. The high-throughput robotic DNA extraction procedure did not adversely affect the sensitivity of the assay compared to manual preparation of PCR templates. This laboratory-based assay provides a rapid and robust method to detect capripoxviruses following suspicion of disease in endemic or disease-free countries. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.
Robinson, Carl; Steward, Karen F; Potts, Nicola; Barker, Colin; Hammond, Toni-ann; Pierce, Karen; Gunnarsson, Eggert; Svansson, Vilhjálmur; Slater, Josh; Newton, J Richard; Waller, Andrew S
2013-08-01
The detection of anti-Streptococcus equi antibodies in the blood serum of horses can assist with the identification of apparently healthy persistently infected carriers and the prevention of strangles outbreaks. The aim of the current study was to use genome sequencing data to develop an indirect enzyme linked immunosorbent assay (iELISA) that targets two S. equi-specific protein fragments. The sensitivity and specificity of the antigen A and antigen C iELISAs were compared to an SeM-based iELISA marketed by IDvet - diagnostic Vétérinaire (IDvet). Individually, each assay compromised specificity in order to achieve sufficient sensitivity (SeM iELISA had a sensitivity of 89.9%, but a specificity of only 77.0%) or sensitivity to achieve high specificity. However, combining the results of the antigen A and antigen C iELISAs permitted optimisation of both sensitivity (93.3%) and specificity (99.3%), providing a robust assay for the identification of horses exposed to S. equi. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan
2015-01-01
To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.
Non-animal sensitization testing: state-of-the-art.
Vandebriel, Rob J; van Loveren, Henk
2010-05-01
Predictive tests to identify the sensitizing properties of chemicals are carried out using animals. In the European Union timelines for phasing out many standard animal tests were established for cosmetics. Following this policy, the new European Chemicals Legislation (REACH) favors alternative methods, if validated and appropriate. In this review the authors aim to provide a state-of-the art overview of alternative methods (in silico, in chemico, and in vitro) to identify contact and respiratory sensitizing capacity and in some occasions give a measure of potency. The past few years have seen major advances in QSAR (quantitative structure-activity relationship) models where especially mechanism-based models have great potential, peptide reactivity assays where multiple parameters can be measured simultaneously, providing a more complete reactivity profile, and cell-based assays. Several cell-based assays are in development, not only using different cell types, but also several specifically developed assays such as three-dimenionally (3D)-reconstituted skin models, an antioxidant response reporter assay, determination of signaling pathways, and gene profiling. Some of these assays show relatively high sensitivity and specificity for a large number of sensitizers and should enter validation (or are indeed entering this process). Integrating multiple assays in a decision tree or integrated testing system is a next step, but has yet to be developed. Adequate risk assessment, however, is likely to require significantly more time and efforts.
Improved sensitivity of vaginal self-collection and high-risk human papillomavirus testing.
Belinson, Jerome L; Du, Hui; Yang, Bin; Wu, Ruifang; Belinson, Suzanne E; Qu, Xinfeng; Pretorius, Robert G; Yi, Xin; Castle, Philip E
2012-04-15
Self-collected vaginal specimens tested for high-risk human papillomavirus (HR-HPV) have been shown to be less sensitive for the detection of cervical intraepithelial neoplasia or cancer (≥CIN 3) than physician-collected endocervical specimens. To increase the sensitivity of self-collected specimens, we studied a self-sampling device designed to obtain a larger specimen from the upper vagina (POI/NIH self-sampler) and a more sensitive polymerase chain reaction (PCR)-based HR-HPV assay. Women (10,000) were screened with cervical cytology and HR-HPV testing of vaginal self-collected and endocervical physician-collected specimens. Women were randomly assigned to use either a novel self-collection device (POI/NIH self-sampler) or conical-shaped brush (Qiagen). The self-collected and clinician-collected specimens were assayed by Cervista (Hologic) and the research only PCR-based matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF). Women with any abnormal screening test underwent colposcopy and biopsy. Women (8,556), mean age of 38.9, had complete data; 1.6% had ≥ CIN 3. For either HR-HPV assay, the sensitivity was similar for the two self-collection devices. Tested with Cervista, the sensitivity for ≥CIN 3 of self-collected specimens was 70.9% and for endocervical specimens was 95.0% (p = 0.0001). Tested with MALDI-TOF, the sensitivity for ≥CIN 3 of self-collected specimens was 94.3% and for endocervical specimens was also 94.3% (p = 1.0). A self-collected sample using a PCR-based assay with the capability of very high throughput has similar sensitivity as a direct endocervical specimen obtained by a physician. Large population-based screening "events" in low-resource settings could be achieved by promoting self-collection and centralized high-throughput, low-cost testing by PCR-based MALDI-TOF. Copyright © 2011 UICC.
Wildi, Karin; Zellweger, Christa; Twerenbold, Raphael; Jaeger, Cedric; Reichlin, Tobias; Haaf, Philip; Faoro, Jonathan; Giménez, Maria Rubini; Fischer, Andreas; Nelles, Berit; Druey, Sophie; Krivoshei, Lian; Hillinger, Petra; Puelacher, Christian; Herrmann, Thomas; Campodarve, Isabel; Rentsch, Katharina; Steuer, Stephan; Osswald, Stefan; Mueller, Christian
2015-01-01
The incremental value of copeptin, a novel marker of endogenous stress, for rapid rule-out of non-ST-elevation myocardial infarction (NSTEMI) is unclear when sensitive or even high-sensitivity cardiac troponin cTn (hs-cTn) assays are used. In an international multicenter study we evaluated 1929 consecutive patients with symptoms suggestive of acute myocardial infarction (AMI). Measurements of copeptin, three sensitive and three hs-cTn assays were performed at presentation in a blinded fashion. The final diagnosis was adjudicated by two independent cardiologists using all clinical information including coronary angiography and levels of hs-cTnT. The incremental value in the diagnosis of NSTEMI was quantified using four outcome measures: area under the receiver-operating characteristic curve (AUC), integrated discrimination improvement (IDI), sensitivity and negative predictive value (NPV). Early presenters (< 4h since chest pain onset) were a pre-defined subgroup. NSTEMI was the adjudicated final diagnosis in 358 (18.6%) patients. As compared to the use of cTn alone, copeptin significantly increased AUC for two (33%) and IDI (between 0.010 and 0.041 (all p < 0.01)), sensitivity and NPV for all six cTn assays (100%); NPV to 96-99% when the 99 th percentile of the respective cTnI assay was combined with a copeptin level of 9 pmol/l (all p < 0.01). The incremental value in early presenters was similar to that of the overall cohort. When used for rapid rule-out of NSTEM in combination with sensitive or hs-cTnI assays, copeptin provides a numerically small, but statistically and likely also clinically significant incremental value. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Parallel Force Assay for Protein-Protein Interactions
Aschenbrenner, Daniela; Pippig, Diana A.; Klamecka, Kamila; Limmer, Katja; Leonhardt, Heinrich; Gaub, Hermann E.
2014-01-01
Quantitative proteome research is greatly promoted by high-resolution parallel format assays. A characterization of protein complexes based on binding forces offers an unparalleled dynamic range and allows for the effective discrimination of non-specific interactions. Here we present a DNA-based Molecular Force Assay to quantify protein-protein interactions, namely the bond between different variants of GFP and GFP-binding nanobodies. We present different strategies to adjust the maximum sensitivity window of the assay by influencing the binding strength of the DNA reference duplexes. The binding of the nanobody Enhancer to the different GFP constructs is compared at high sensitivity of the assay. Whereas the binding strength to wild type and enhanced GFP are equal within experimental error, stronger binding to superfolder GFP is observed. This difference in binding strength is attributed to alterations in the amino acids that form contacts according to the crystal structure of the initial wild type GFP-Enhancer complex. Moreover, we outline the potential for large-scale parallelization of the assay. PMID:25546146
Parallel force assay for protein-protein interactions.
Aschenbrenner, Daniela; Pippig, Diana A; Klamecka, Kamila; Limmer, Katja; Leonhardt, Heinrich; Gaub, Hermann E
2014-01-01
Quantitative proteome research is greatly promoted by high-resolution parallel format assays. A characterization of protein complexes based on binding forces offers an unparalleled dynamic range and allows for the effective discrimination of non-specific interactions. Here we present a DNA-based Molecular Force Assay to quantify protein-protein interactions, namely the bond between different variants of GFP and GFP-binding nanobodies. We present different strategies to adjust the maximum sensitivity window of the assay by influencing the binding strength of the DNA reference duplexes. The binding of the nanobody Enhancer to the different GFP constructs is compared at high sensitivity of the assay. Whereas the binding strength to wild type and enhanced GFP are equal within experimental error, stronger binding to superfolder GFP is observed. This difference in binding strength is attributed to alterations in the amino acids that form contacts according to the crystal structure of the initial wild type GFP-Enhancer complex. Moreover, we outline the potential for large-scale parallelization of the assay.
Plant compounds enhance the assay sensitivity for detection of active Bacillus cereus toxin.
Rasooly, Reuven; Hernlem, Bradley; He, Xiaohua; Friedman, Mendel
2015-03-11
Bacillus cereus is an important food pathogen, producing emetic and diarrheal syndromes, the latter mediated by enterotoxins. The ability to sensitively trace and identify this active toxin is important for food safety. This study evaluated a nonradioactive, sensitive, in vitro cell-based assay, based on B. cereus toxin inhibition of green fluorescent protein (GFP) synthesis in transduced monkey kidney Vero cells, combined with plant extracts or plant compounds that reduce viable count of B. cereus in food. The assay exhibited a dose dependent GFP inhibition response with ~25% inhibition at 50 ng/mL toxin evaluated in culture media or soy milk, rice milk or infant formula, products associated with food poisonings outbreak. The plant extracts of green tea or bitter almond and the plant compounds epicatechin or carvacrol were found to amplify the assay response to ~90% inhibition at the 50 ng/mL toxin concentration greatly increasing the sensitivity of this assay. Additional studies showed that the test formulations also inhibited the growth of the B. cereus bacteria, likely through cell membrane disruption. The results suggest that the improved highly sensitive assay for the toxin and the rapid inactivation of the pathogen producing the toxin have the potential to enhance food safety.
Li, Jingwen; Li, Xinming; Shi, Xiujuan; He, Xuewen; Wei, Wei; Ma, Nan; Chen, Hong
2013-10-09
We describe here a simple fluorometric assay for the highly sensitive detection of caspase-3 activities on the basis of the inner-filter effect of gold nanoparticles (AuNPs) on CdTe quantum dots (QDs). The method takes advantage of the high molar absorptivity of the plasmon band of gold nanoparticles as well as the large absorption band shift from 520 to 680 nm upon nanoparticle aggregation. When labeled with a peptide possessing the caspase-3 cleavage sequence (DEVD), the monodispersed Au-Ps (peptide-modified AuNPs) exhibited a tendency to aggregate when exposed to caspase-3, which induced the absorption band transition from 520 to 680 nm and turned on the fluorescence of the CdTe QDs for caspase-3 sensing. Under optimum conditions, a high sensitivity towards caspase-3 was achieved with a detection limit as low as 18 pM, which was much lower than the corresponding assays based on absorbance or other approaches. Overall, we demonstrated a facile and sensitive approach for caspase-3 detection, and we expected that this method could be potentially generalized to design more fluorescent assays for sensing other bioactive entities.
Development of an updated PCR assay for detection of African swine fever virus.
Luo, Yuzi; Atim, Stella A; Shao, Lina; Ayebazibwe, Chrisostom; Sun, Yuan; Liu, Yan; Ji, Shengwei; Meng, Xing-Yu; Li, Su; Li, Yongfeng; Masembe, Charles; Ståhl, Karl; Widén, Frederik; Liu, Lihong; Qiu, Hua-Ji
2017-01-01
Due to the current unavailability of vaccines or treatments for African swine fever (ASF), which is caused by African swine fever virus (ASFV), rapid and reliable detection of the virus is essential for timely implementation of emergency control measures and differentiation of ASF from other swine diseases with similar clinical presentations. Here, an improved PCR assay was developed and evaluated for sensitive and universal detection of ASFV. Primers specific for ASFV were designed based on the highly conserved region of the vp72 gene sequences of all ASFV strains available in GenBank, and the PCR assay was established and compared with two OIE-validated PCR tests. The analytic detection limit of the PCR assay was 60 DNA copies per reaction. No amplification signal was observed for several other porcine viruses. The novel PCR assay was more sensitive than two OIE-validated PCR assays when testing 14 strains of ASFV representing four genotypes (I, V, VIII and IX) from diverse geographical areas. A total of 62 clinical swine blood samples collected from Uganda were examined by the novel PCR, giving a high agreement (59/62) with a superior sensitive universal probe library-based real-time PCR. Eight out of 62 samples tested positive, and three samples with higher Ct values (39.15, 38.39 and 37.41) in the real-time PCR were negative for ASFV in the novel PCR. In contrast, one (with a Ct value of 29.75 by the real-time PCR) and two (with Ct values of 29.75 and 33.12) ASFV-positive samples were not identified by the two OIE-validated PCR assays, respectively. Taken together, these data show that the novel PCR assay is specific, sensitive, and applicable for molecular diagnosis and surveillance of ASF.
Nowak, Rebecca G; Ambulos, Nicholas P; Schumaker, Lisa M; Mathias, Trevor J; White, Ruth A; Troyer, Jennifer; Wells, David; Charurat, Manhattan E; Bentzen, Søren M; Cullen, Kevin J
2017-06-13
Our next generation sequencing (NGS)-based human papillomavirus (HPV) genotyping assay showed a high degree of concordance with the Roche Linear Array (LA) with as little as 1.25 ng formalin-fixed paraffin-embedded-derived genomic DNA in head and neck and cervical cancer samples. This sensitive genotyping assay uses barcoded HPV PCR broad-spectrum general primers 5+/6+ (BSGP)5+/6+ applicable to population studies, but it's diagnostic performance has not been tested in cases with multiple concurrent HPV infections. We conducted a cross-sectional study to compare the positive and negative predictive value (PPV and NPV), sensitivity and specificity of the NGS assay to detect HPV genotype infections as compared to the LA. DNA was previously extracted from ten anal swab samples from men who have sex with men in Nigeria enrolled on the TRUST/RV368 cohort study. Two-sample tests of proportions were used to examine differences in the diagnostic performance of the NGS assay to detect high vs. low-risk HPV type-specific infections. In total there were 94 type-specific infections detected in 10 samples with a median of 9.5, range (9 to 10) per sample. Using the LA as the gold standard, 84.4% (95% CI: 75.2-91.2) of the same anal type-specific infections detected on the NGS assay had been detected by LA. The PPV and sensitivity differed significantly for high risk (PPV: 90%, 95% CI: 79.5-96.2; sensitivity: 93.1%, 95% CI: 83.3-98.1) as compared to low risk HPV (PPV: 73%, 95% CI: 54.1-87.7; sensitivity: 61.1, 95% CI: 43.5-76.9) (all p < 0.05). The NPV for all types was 92.5% (95% CI: 88.4-95.4). The NPV and specificity were similar for high and low risk HPVs (all p > 0.05). The NGS assay detected 10 HPV genotypes that were not among the 37 genotypes found on LA (30, 32, 43, 44, 74, 86, 87, 90, 91, 114). The NGS assay accurately detects multiple HPV infections in individual clinical specimens with limited sample volume and has extended coverage compared to LA.
Cao, Biyun; He, Guangzhao; Yang, Hong; Chang, Huafang; Li, Shuqun; Deng, Anping
2013-10-15
Phenylethanolamine A (PA) is a new emerged β-adrenergic agonist illegally used as feed additives for growth promotion. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of PA in tissue and feed samples was developed and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). By reduction of nitryl group to amino group, the PA derivative was synthesized and coupled to carrier proteins with diazobenzidine method. The antisera obtained from four immunized rabbits were characterized in terms of sensitivity and specificity. All antisera displayed high sensitivity with IC50 values lower than 0.48 ng mL(-1). The most sensitive ELISA was established with IC50 and limit of detection (LOD) values of 0.049 ng mL(-1) and 0.003 ng mL(-1), respectively. The cross-reactivity (CR) values of the antisera with three frequently used β-adrenergic agonists (clenbuterol, salbutamol and ractopamine) were lesser than 0.39%; there was no CR of the antisera with other six compounds including two structurally related substances (isoproterenol, phenylephrine). To investigate the accuracy and precision of the assay, swine kidney, liver, meat and feed samples were fortified with PA at different content and analyzed by ELISA. Acceptable recovery rates of 92.2-113.7% and intra-assay coefficients of variation of 3.8-10.9% (n=3) were achieved. Seven spiked samples were simultaneously analyzed by ELISA and LC-MS/MS. There was a high correlation coefficient of 0.9956 (n=7) between the two methods. The proposed ELISA proven to be a feasible quantitative/screening method for PA analysis in tissue and feed samples with the properties of high sensitivity and specificity, high sample throughput and low expensive. © 2013 Elsevier B.V. All rights reserved.
Dettinger, Lisa; Powell, James W.; Seiders, Melanie; Condori, Rene Edgar Condori; Griesser, Richard; Okogi, Kenneth; Carlos, Maria; Pesko, Kendra; Breckenridge, Mike; Simon, Edson Michael M.; Chu, Maria Yna Joyce V.; Davis, April D.; Brunt, Scott J.; Orciari, Lillian; Yager, Pamela; Carson, William C.; Hartloge, Claire; Saliki, Jeremiah T.; Deldari, Mojgan; Hsieh, Kristina; Wadhwa, Ashutosh; Wilkins, Kimberly; Rabideau, Patricia; Gruhn, Nina; Cadet, Rolain; Isloor, Shrikrishna; Nath, Sujith S.; Joseph, Tomy; Gao, Jinxin; Wallace, Ryan; Reynolds, Mary; Olson, Victoria A.
2018-01-01
Rabies is a fatal zoonotic disease that requires fast, accurate diagnosis to prevent disease in an exposed individual. The current gold standard for post-mortem diagnosis of human and animal rabies is the direct fluorescent antibody (DFA) test. While the DFA test has proven sensitive and reliable, it requires high quality antibody conjugates, a skilled technician, a fluorescence microscope and diagnostic specimen of sufficient quality. The LN34 pan-lyssavirus real-time RT-PCR assay represents a strong candidate for rabies post-mortem diagnostics due to its ability to detect RNA across the diverse Lyssavirus genus, its high sensitivity, its potential for use with deteriorated tissues, and its simple, easy to implement design. Here, we present data from a multi-site evaluation of the LN34 assay in 14 laboratories. A total of 2,978 samples (1,049 DFA positive) from Africa, the Americas, Asia, Europe, and the Middle East were tested. The LN34 assay exhibited low variability in repeatability and reproducibility studies and was capable of detecting viral RNA in fresh, frozen, archived, deteriorated and formalin-fixed brain tissue. The LN34 assay displayed high diagnostic specificity (99.68%) and sensitivity (99.90%) when compared to the DFA test, and no DFA positive samples were negative by the LN34 assay. The LN34 assay produced definitive findings for 80 samples that were inconclusive or untestable by DFA; 29 were positive. Five samples were inconclusive by the LN34 assay, and only one sample was inconclusive by both tests. Furthermore, use of the LN34 assay led to the identification of one false negative and 11 false positive DFA results. Together, these results demonstrate the reliability and robustness of the LN34 assay and support a role for the LN34 assay in improving rabies diagnostics and surveillance. PMID:29768505
Zhao, Lihong; Li, Ruiying; Liu, Aihua; Zhao, Shuping
2015-07-01
The objective of this study was to build and apply a duplex real time quantitative reverse transcription-polymerase chain reaction (RT-PCR) for rubella virus. Firstly, a 60-bp-long armored RV RNA was constructed in the laboratory. Secondly, a duplex real time RT-PCR assay was established. Thirdly, the 60-bp-long armored RV RNA was used as an internal positive control (IPC) for the duplex real time RT-PCR. And finally the duplex real time RT-PCR assay was applied to detect RV RNA in clinical specimens. The in-house assay has a high amplification efficiency (0.99), a high analytical sensitivity (200 copies/mL), and a good reproducibility. The diagnostic specificity and sensitivity of the in-house assay were both 100%, due to the monitoring of the armored RV RNA IPC. Therefore, the in-house duplex real time quantitative RT-PCR assay is a specific, sensitive, reproducible and accurate assay for quantitation of RV RNA in clinical specimens. And noncompetitive armored RV RNA IPC can monitor RT-PCR inhibition and prevent false-negative and inaccurate results in the real time detection system. Copyright © 2015 Elsevier B.V. All rights reserved.
77 FR 11137 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... nonspecific, and the diagnosis is frequently difficult and delayed. The inventors established a rapid ELISA assay to evaluate biomarker levels in serum. The ELISA assay tests a novel combination of two biomarkers...-invasive ELISA serum assay. Potential for high sensitivity. Cost effective. Development Stage: Pilot. Early...
Formichella, Luca; Romberg, Laura; Bolz, Christian; Vieth, Michael; Geppert, Michael; Göttner, Gereon; Nölting, Christina; Walter, Dirk; Schepp, Wolfgang; Schneider, Arne; Ulm, Kurt; Wolf, Petra; Busch, Dirk H; Soutschek, Erwin; Gerhard, Markus
2013-11-01
Helicobacter pylori colonizes half of the world's population, and infection can lead to ulcers, gastric cancer, and mucosa-associated lymphoid tissue (MALT) lymphoma. Serology is the only test applicable for large-scale, population-based screening, but current tests are hampered by a lack of sensitivity and/or specificity. Also, no serologic test allows the differentiation of type I and type II strains, which is important for predicting the clinical outcome. H. pylori virulence factors have been associated with disease, but direct assessment of virulence factors requires invasive methods to obtain gastric biopsy specimens. Our work aimed at the development of a highly sensitive and specific, noninvasive serologic test to detect immune responses to important H. pylori virulence factors. This line immunoassay system (recomLine) is based on recombinant proteins. For this assay, six highly immunogenic virulence factors (CagA, VacA, GroEL, gGT, HcpC, and UreA) were expressed in Escherichia coli, purified, and immobilized to nitrocellulose membranes to detect serological immune responses in patient's sera. For the validation of the line assay, a cohort of 500 patients was screened, of which 290 (58.0%) were H. pylori negative and 210 (42.0%) were positive by histology. The assay showed sensitivity and specificity of 97.6% and 96.2%, respectively, compared to histology. In direct comparison to lysate blotting and enzyme-linked immunosorbent assay (ELISA), the recomLine assay had increased discriminatory power. For the assessment of individual risk for gastrointestinal disease, the test must be validated in a larger and defined patient cohort. Taking the data together, the recomLine assay provides a valuable tool for the diagnosis of H. pylori infection.
Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo
2016-01-01
Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.
Guzman, Maria G.; Jaenisch, Thomas; Gaczkowski, Roger; Ty Hang, Vo Thi; Sekaran, Shamala Devi; Kroeger, Axel; Vazquez, Susana; Ruiz, Didye; Martinez, Eric; Mercado, Juan C.; Balmaseda, Angel; Harris, Eva; Dimano, Efren; Leano, Prisca Susan A.; Yoksan, Sutee; Villegas, Elci; Benduzu, Herminia; Villalobos, Iris; Farrar, Jeremy; Simmons, Cameron P.
2010-01-01
Background Early diagnosis of dengue can assist patient triage and management and prevent unnecessary treatments and interventions. Commercially available assays that detect the dengue virus protein NS1 in the plasma/serum of patients offers the possibility of early and rapid diagnosis. Methodology/Principal Findings The sensitivity and specificity of the Pan-E Dengue Early ELISA and the Platelia™ Dengue NS1 Ag assays were compared against a reference diagnosis in 1385 patients in 6 countries in Asia and the Americas. Platelia was more sensitive (66%) than Pan-E (52%) in confirmed dengue cases. Sensitivity varied by geographic region, with both assays generally being more sensitive in patients from SE Asia than the Americas. Both kits were more sensitive for specimens collected within the first few days of illness onset relative to later time points. Pan-E and Platelia were both 100% specific in febrile patients without evidence of acute dengue. In patients with other confirmed diagnoses and healthy blood donors, Platelia was more specific (100%) than Pan-E (90%). For Platelia, when either the NS1 test or the IgM test on the acute sample was positive, the sensitivity versus the reference result was 82% in samples collected in the first four days of fever. NS1 sensitivity was not associated to disease severity (DF or DHF) in the Platelia test, whereas a trend for higher sensitivity in DHF cases was seen in the Pan-E test (however combined with lower overall sensitivity). Conclusions/Significance Collectively, this multi-country study suggests that the best performing NS1 assay (Platelia) had moderate sensitivity (median 64%, range 34–76%) and high specificity (100%) for the diagnosis of dengue. The poor sensitivity of the evaluated assays in some geographical regions suggests further assessments are needed. The combination of NS1 and IgM detection in samples collected in the first few days of fever increased the overall dengue diagnostic sensitivity. PMID:20824173
NASA Astrophysics Data System (ADS)
Cui, Wei; Parker, Laurie L.
2016-07-01
Fluorescent drug screening assays are essential for tyrosine kinase inhibitor discovery. Here we demonstrate a flexible, antibody-free TR-LRET kinase assay strategy that is enabled by the combination of streptavidin-coated quantum dot (QD) acceptors and biotinylated, Tb3+ sensitizing peptide donors. By exploiting the spectral features of Tb3+ and QD, and the high binding affinity of the streptavidin-biotin interaction, we achieved multiplexed detection of kinase activity in a modular fashion without requiring additional covalent labeling of each peptide substrate. This strategy is compatible with high-throughput screening, and should be adaptable to the rapidly changing workflows and targets involved in kinase inhibitor discovery.
Ginocchio, C. C.; Barth, D.; Zhang, F.
2008-01-01
This study compared the clinical performance of the Digene Hybrid Capture 2 (HC2) assay to that of a prototype Third Wave Invader human papillomavirus (HPV) (IHPV) analyte-specific reagent-based assay for the detection of oncogenic or “high-risk” (HR) HPV DNA using liquid-based cytology specimens. In total, 821 ThinPrep vials were tested using both assays. In accordance with the type-specific probes contained within each test, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the IHPV assay were 95.9%, 97.6%, 97.5%, and 96.1%, respectively, and those for the HC2 assay were 98.1%, 86.2%, 87.1%, and 97.9%. Overall, the sensitivity and NPV were comparable between the assays, but the IHPV assay demonstrated a better specificity and PPV, since the IHPV assay had fewer false-positive HR HPV results. The incorporation of an internal control to evaluate the cellularity of the test material is an important feature of the IHPV assay and should reduce the risk of false-negative results due to insufficient sample collection rather than the lack of HR HPV DNA. An additional benefit of the IHPV assay was the smaller sample volume required (1 ml versus 4 ml for the HC2 assay). PMID:18367578
Monaghan, S J; Thompson, K D; Adams, A; Bergmann, S M
2015-03-01
Koi herpesvirus (KHV) causes an economically important, highly infectious disease in common carp and koi, Cyprinus carpio L. Since the occurrence of mass mortalities worldwide, highly specific and sensitive molecular diagnostic methods have been developed for KHV detection. The sensitivity and reliability of these assays have essentially focused at the detection of low viral DNA copy numbers during latent or persistent infections. However, the efficacy of these assays has not been investigated with regard to low-level viraemia during acute infection stages. This study was conducted to compare the sensitivity of seven different polymerase chain reaction (PCR) assays to detect KHV during the first hours and days post-infection (hpi; dpi), using lethal and non-lethal sampling methods. The results highlight the limitations of the assays for detecting virus during the first 4 dpi despite rapid mortality in experimentally infected carp. False-negative results were associated with time post-infection and the tissue sampled. Non-lethal sampling appears effective for KHV screening, with efficient detection in mucus samples obtained from external swabs during this early infection period (<5 dpi), while biopsies from gills and kidney were negative using the same PCR assays. Non-lethal sampling may improve the reliability of KHV detection in subclinical, acutely infected carp. © 2014 John Wiley & Sons Ltd.
Mohimen, A; Ahmed, A R
1995-01-01
Some patients with pemphigus vulgaris (PV) have positive direct immunofluorescence (DIF) but are negative by indirect immunofluorescence (IIF). The purpose of this study was (1) to compare the sensitivity of an IIF assay with an immunoblot (IB) assay, (2) to compare the IIF and the IB assay in PV patients in whom the clinical picture and DIF were consistent, but the IIF was negative and (3) to compare the IIF and the IB assay in patients in clinical remission for 3 years or more. A comparison was made of the titers of PV autoantibody in the IIF assay using monkey esophagus as substrate and the modified sensitive IB assay using preabsorbed normal human skin lysate and COLO-16 lysate as a substrate in the three groups of patients. The sensitivity of the Western blot was enhanced by modifications in the extraction procedure of the lysate, by absorption of lysate with normal human serum and by the use of an enzygraphic web. In group 1, comprising 23 PV patients with active generalized disease, the titers of the autoantibody in the IB assay were 2-4-fold higher than in the IIF assay. This difference was highly significant (P = 0.0001). In group 2, comprising 10 patients with limited or minimal PV who were positive on DIF and negative on IIF, all the patients were positive in the IB assay. In group 3, comprising 9 patients clinically free of disease and off all therapy for at least 3 years and negative in IIF assay, all the patients were positive in the IB assay.(ABSTRACT TRUNCATED AT 250 WORDS)
This describes fluorogenic 5' nuclease PCR assays suitable for rapid, sensitive, quantitative, high-throughput detection of the human-pathogenic microsporidial species Encephalitozoon hellem, E. cunicli and E. intestinalis. The assays utilize species-specific primer sets and a g...
76 FR 4920 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
... appear to be distinct from each other. Available for licensing is a Plk1 ELISA assay using peptide... binding property, an easy and reliable ELISA assay has been developed to quantify Plk1 expression levels... sequence. ELISA assay to quantify Plk1 expression and kinase activity. Advantages: Rapid, highly sensitive...
Mirzai, S; Safi, S; Mossavari, N; Afshar, D; Bolourchian, M
2016-08-31
The present study was conducted to establish a Loop-mediated isothermal amplification (LAMP) technique for the rapid detection of B. mallei the etiologic agent of glanders, a highly contagious disease of equines. A set of six specific primers targeting integrase gene cluster were designed for the LAMP test. The reaction was optimized using different temperatures and time intervals. The specificity of the assay was evaluated using DNA from B.pseudomallei and Pseudomonas aeruginosa. The LAMP products were analyzed both visually and under UV light after electrophoresis. The optimized conditions were found to be at 63ºC for 60 min. The assay showed high specificity and sensitivity. It was concluded that the established LAMP assay is a rapid, sensitive and practical tool for detection of B. mallei and early diagnosis of glanders.
A ``plasmonic cuvette'': dye chemistry coupled to plasmonic interferometry for glucose sensing
NASA Astrophysics Data System (ADS)
Siu, Vince S.; Feng, Jing; Flanigan, Patrick W.; Palmore, G. Tayhas R.; Pacifici, Domenico
2014-06-01
A non-invasive method for the detection of glucose is sought by millions of diabetic patients to improve personal management of blood glucose over a lifetime. In this work, the synergistic advantage of combining plasmonic interferometry with an enzyme-driven dye assay yields an optical sensor capable of detecting glucose in saliva with high sensitivity and selectivity. The sensor, coined a "plasmonic cuvette," is built around a nano-scale groove-slit-groove (GSG) plasmonic interferometer coupled to an Amplex-red/Glucose-oxidase/Glucose (AR/GOx/Glucose) assay. The proposed device is highly sensitive, with a measured intensity change of 1.7×105%/m (i.e., one order of magnitude more sensitive than without assay) and highly specific for glucose sensing in picoliter volumes, across the physiological range of glucose concentrations found in human saliva (20-240 μm). Real-time glucose monitoring in saliva is achieved by performing a detailed study of the underlying enzyme-driven reactions to determine and tune the effective rate constants in order to reduce the overall assay reaction time to ˜2 min. The results reported suggest that by opportunely choosing the appropriate dye chemistry, a plasmonic cuvette can be turned into a general, real-time sensing scheme for detection of any molecular target, with high sensitivity and selectivity, within extremely low volumes of biological fluid (down to femtoliters). Hereby, we present the results on glucose detection in artificial saliva as a notable and clinically relevant case study.
Fonseca, M E; Marcellino, L H; Gander, E
1996-04-05
A rapid and sensitive dot-blot hybridization assay using in vitro-transcribed digoxigenin-labelled RNA probes (riboprobes) was developed aiming at detection of citrus exocortis viroid (CEVd) in crude sap of infected Citrus medica plants. The protocol includes a very quick and simple preparation of RNA extracts from samples using a denaturation step with formaldehyde. From our results, the employment of this step is highly recommended because the hybridization signals in formaldehyde-denatured samples were significantly stronger when compared with that of extracts without formaldehyde treatment. The assay was found to be sensitive enough to detect 0.1 ng of purified CEVd RNA and was able to detect viroid in 0.2 mg of symptomatic Citrus medica leaves. The use of riboprobes also allowed hybridization under high temperature conditions, avoiding non-specific background.
Development of fluorescent methods for DNA methyltransferase assay
NASA Astrophysics Data System (ADS)
Li, Yueying; Zou, Xiaoran; Ma, Fei; Tang, Bo; Zhang, Chun-yang
2017-03-01
DNA methylation modified by DNA methyltransferase (MTase) plays an important role in regulating gene transcription, cell growth and proliferation. The aberrant DNA MTase activity may lead to a variety of human diseases including cancers. Therefore, accurate and sensitive detection of DNA MTase activity is crucial to biomedical research, clinical diagnostics and therapy. However, conventional DNA MTase assays often suffer from labor-intensive operations and time-consuming procedures. Alternatively, fluorescent methods have significant advantages of simplicity and high sensitivity, and have been widely applied for DNA MTase assay. In this review, we summarize the recent advances in the development of fluorescent methods for DNA MTase assay. These emerging methods include amplification-free and the amplification-assisted assays. Moreover, we discuss the challenges and future directions of this area.
Clinical validation of the Tempus xO assay
Beaubier, Nike; Tell, Robert; Huether, Robert; Bontrager, Martin; Bush, Stephen; Parsons, Jerod; Shah, Kaanan; Baker, Tim; Selkov, Gene; Taxter, Tim; Thomas, Amber; Bettis, Sam; Khan, Aly; Lau, Denise; Lee, Christina; Barber, Matthew; Cieslik, Marcin; Frankenberger, Casey; Franzen, Amy; Weiner, Ali; Palmer, Gary; Lonigro, Robert; Robinson, Dan; Wu, Yi-Mi; Cao, Xuhong; Lefkofsky, Eric; Chinnaiyan, Arul; White, Kevin P.
2018-01-01
We have developed a clinically validated NGS assay that includes tumor, germline and RNA sequencing. We apply this assay to clinical specimens and cell lines, and we demonstrate a clinical sensitivity of 98.4% and positive predictive value of 100% for the clinically actionable variants measured by the assay. We also demonstrate highly accurate copy number measurements and gene rearrangement identification. PMID:29899824
Towards sensitive, high-throughput, biomolecular assays based on fluorescence lifetime
NASA Astrophysics Data System (ADS)
Ioanna Skilitsi, Anastasia; Turko, Timothé; Cianfarani, Damien; Barre, Sophie; Uhring, Wilfried; Hassiepen, Ulrich; Léonard, Jérémie
2017-09-01
Time-resolved fluorescence detection for robust sensing of biomolecular interactions is developed by implementing time-correlated single photon counting in high-throughput conditions. Droplet microfluidics is used as a promising platform for the very fast handling of low-volume samples. We illustrate the potential of this very sensitive and cost-effective technology in the context of an enzymatic activity assay based on fluorescently-labeled biomolecules. Fluorescence lifetime detection by time-correlated single photon counting is shown to enable reliable discrimination between positive and negative control samples at a throughput as high as several hundred samples per second.
Wong, Chin Lin; Lam, Ai-Leen; Smith, Maree T.; Ghassabian, Sussan
2016-01-01
The direct peptide reactivity assay (DPRA) is a validated method for in vitro assessment of the skin sensitization potential of chemicals. In the present work, we describe a peptide reactivity assay using 96-well plate format and systematically identified the optimal assay conditions for accurate and reproducible classification of chemicals with known sensitizing capacity. The aim of the research is to ensure that the analytical component of the peptide reactivity assay is robust, accurate, and reproducible in accordance with criteria that are used for the validation of bioanalytical methods. Analytical performance was evaluated using quality control samples (QCs; heptapeptides at low, medium, and high concentrations) and incubation of control chemicals (chemicals with known sensitization capacity, weak, moderate, strong, extreme, and non-sensitizers) with each of three synthetic heptapeptides, viz Cor1-C420 (Ac-NKKCDLF), cysteine- (Ac-RFAACAA), and lysine- (Ac-RFAAKAA) containing heptapeptides. The optimal incubation temperature for all three heptapeptides was 25°C. Apparent heptapeptide depletion was affected by vial material composition. Incubation of test chemicals with Cor1-C420, showed that peptide depletion was unchanged in polypropylene vials over 3-days storage in an autosampler but this was not the case for borosilicate glass vials. For cysteine-containing heptapeptide, the concentration was not stable by day 3 post-incubation in borosilicate glass vials. Although the lysine-containing heptapeptide concentration was unchanged in both polypropylene and borosilicate glass vials, the apparent extent of lysine-containing heptapeptide depletion by ethyl acrylate, differed between polypropylene (24.7%) and glass (47.3%) vials. Additionally, the peptide-chemical complexes for Cor1-C420-cinnamaldehyde and cysteine-containing heptapeptide-2, 4-dinitrochlorobenzene were partially reversible during 3-days of autosampler storage. These observations further highlight the difficulty in adapting in vitro methods to high-throughput format for screening the skin sensitization potential of large numbers of chemicals whilst ensuring that the data produced are both accurate and reproducible. PMID:27014067
Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.
Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk
2013-06-01
The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.
Gollapudi, Deepika; Wycuff, Diane L; Schwartz, Richard M; Cooper, Jonathan W; Cheng, K C
2017-10-01
In this paper, we describe development of a high-throughput, highly sensitive method based on Lab Chip CGE-SDS platform for purity determination and characterization of virus-like particle (VLP) vaccines. A capillary gel electrophoresis approach requiring about 41 s per sample for analysis and demonstrating sensitivity to protein initial concentrations as low as 20 μg/mL, this method has been used previously to evaluate monoclonal antibodies, but this application for lot release assay of VLPs using this platform is unique. The method was qualified and shown to be accurate for the quantitation of VLP purity. Assay repeatability was confirmed to be less than 2% relative standard deviation of the mean (% RSD) with interday precision less than 2% RSD. The assay can evaluate purified VLPs in a concentration range of 20-249 μg/mL for VEE and 20-250 μg/mL for EEE and WEE VLPs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
AbstractHigh-throughput methods are useful for rapidly screening large numbers of chemicals for biological activity, including the perturbation of pathways that may lead to adverse cellular effects. In vitro assays for the key events of neurodevelopment, including apoptosis, may ...
Li, Yuping; Xu, Hanyan; Su, Shanshan; Ye, Junru; Chen, Junjie; Jin, Xuru; Lin, Quan; Zhang, Dongqing; Ye, Caier; Chen, Chengshui
2017-01-01
Circulating tumor DNA (ctDNA) is a promising biomarker for noninvasive epidermal growth factor receptor (EGFR) mutations detection in lung cancer patients, but the existing methods have limitations in sensitivity or in availability. In this study, we evaluated the performance of a novel assay called ADx-SuperARMS in detecting EGFR mutations in plasma cell-free DNA from patients with advanced lung adenocarcinoma. A total of 109 patients with metastatic advanced adenocarcinoma were recruited who provided both blood samples and matched tumor tissue samples. EGFR mutation status in plasma samples were tested with ADx-SuperARMS EGFR assay and tumor tissue samples were tested with ADx-ARMS EGFR assay. The clinical sensitivity, specificity, positive prediction value (PPV), and negative prediction value (NPV) of ADx-SuperARMS EGFR assay were calculated by using EGFR mutation status in tumor tissue as standard reference. A receiver operating characteristic (ROC) analysis was implemented and an area under the curve (AUC) was calculated to evaluate sensitivity and specificity of exon 19 deletion (E19Del) and L858R mutation detection. The objective response rate (ORR) were calculated according to the EGFR mutation status determined by ADx-superARMS as well. 0.2% analytical sensitivity and 100% specificity of the ADx-SuperARMS EGFR assays for EGFR E19Del, L858R, and T790M mutants were confirmed by using a series of diluted cell line DNA. In the clinical study, EGFR mutations were detected in 45.9% (50/109) of the plasma samples and in 56.9% (62/109) of the matched tumor tissue samples. The sensitivity, specificity, PPV and NPV of the ADx-SuperARMS EGFR assay for plasma EGFR mutation detection were 82.0% (50/61), 100% (48/48), 100% (50/50), and 81.4% (48/59), respectively. In ROC analysis, ADx-SuperARMS achieved sensitivity and specificity of 88% and 99% in E19Dels as well as sensitivity and specificity of 89% and 100% in L858R, respectively. Among the 35 patients who were plasma EGFR mutation positive and treated with first generation of EGFR-tyrosine kinase inhibitors (TKIs), 23 (65.7%) achieved partial response, 11 (31.4%) sustained disease, and 1 (2.9%) progressive disease. The ORR and disease control rate (DCR) were 65.7% and 97.1%, respectively. ADx-SuperARMS EGFR assay is likely to be a highly sensitive and specific method to noninvasively detect plasma EGFR mutations of patients with advanced lung adenocarcinoma. The EGFR mutations detected by ADx-SuperARMS EGFR assay could predict the efficacy of the treatment with first generation of EGFR-TKIs. Hence, EGFR blood testing with ADx-SuperARMS could address the unmet clinical needs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jun; Liu, Guodong; Wu, Hong
2008-01-01
In this paper, we demonstrate an electrochemical high-throughput sensing platform for simple, sensitive detection of PSA based on QD labels. This sensing platform uses a microplate for immunoreactions and disposable screen-printed electrodes (SPE) for electrochemical stripping analysis of metal ions released from QD labels. With the 96-well microplate, capturing antibodies are conveniently immobilized to the well surface, and the process of immunoreaction is easily controlled. The formed sandwich complexes on the well surface are also easily isolated from reaction solutions. In particular, a microplate-based electrochemical assay can make it feasible to conduct a parallel analysis of several samples or multiplemore » protein markers. This assay offers a number of advantages including (1) simplicity, cost-effectiveness, (2) high sensitivity, (3) capability to sense multiple samples or targets in parallel, and (4) a potentially portable device with an SPE array implanted in the microplate. This PSA assay is sensitive because it uses two amplification processes: (1) QDs as a label for enhancing electrical signal since secondary antibodies are linked to QDs that contain a large number of metal atoms and (2) there is inherent signal amplification for electrochemical stripping analysis—preconcentration of metal ion onto the electrode surface for amplifying electrical signals. Therefore, the high sensitivity of this method, stemming from dual signal amplification via QD labels and pre-concentration, allows low concentration levels to be detected while using small sample volumes. Thus, this QD-based electrochemical detection approach offers a simple, rapid, cost-effective, and high throughput assay of PSA.« less
Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi
2013-01-01
We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring. PMID:23946517
Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito
2013-11-01
We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring.
Ho, Stephen K. N.; Chan, Tak Mao; Cheng, Ignatius K. P.; Lai, Kar Neng
1999-01-01
The optimal hepatitis B virus (HBV) DNA quantitative assay for clinical use remains to be determined. We examined the sensitivity, linearity, and variability of a novel second-generation antibody capture solution hybridization assay, the Digene Hybrid Capture II assay (HCII), and compared it with another widely used solution hybridization assay, the branched-DNA (bDNA) assay (Quantiplex; Chiron Corp.). Our results showed similar and satisfactory assay linearity values, as well as interassay and intra-assay variability values, for both HCII and bDNA assays across different ranges of HBV DNA. Ninety-one percent of 102 serum samples from hepatitis B surface antigen-positive patients showed concordant results with the two assays. The HCII assay was more sensitive than the bDNA assay by 1 dilution, with the lowest reading being 0.9 pg/ml (3.8 pg/ml by bDNA assay). The HBV DNA seropositivity rates for the 102 samples were 58, 67, and 97% by bDNA, HCII, and nested PCR, respectively. While the relationship between results obtained with the bDNA assay and those with the HCII assay was nonlinear, with the bDNA assay yielding values 2.83 ± 0.92-fold higher than those of the HCII assay, especially at high HBV DNA levels, a linear relationship was observed between the two sets of data after logarithmic conversion. The formula for interassay conversion of results was derived as follows: HBV DNA by HCII (picograms per milliliter) = 3.19 × [HBV DNA by bDNA (megaequivalents per milliliter)]0.866. The HCII assay was technically less complex and required a shorter assay time (4 h) than the bDNA assay (24 h). We conclude that the HCII assay compares favorably with the bDNA assay and offers the additional advantages of increased sensitivity and shorter assay time. The increased sensitivity should be particularly useful in monitoring the efficacy of antiviral therapies and detecting the emergence of drug-resistant HBV mutants. PMID:10405385
Ho, S K; Chan, T M; Cheng, I K; Lai, K N
1999-08-01
The optimal hepatitis B virus (HBV) DNA quantitative assay for clinical use remains to be determined. We examined the sensitivity, linearity, and variability of a novel second-generation antibody capture solution hybridization assay, the Digene Hybrid Capture II assay (HCII), and compared it with another widely used solution hybridization assay, the branched-DNA (bDNA) assay (Quantiplex; Chiron Corp.). Our results showed similar and satisfactory assay linearity values, as well as interassay and intra-assay variability values, for both HCII and bDNA assays across different ranges of HBV DNA. Ninety-one percent of 102 serum samples from hepatitis B surface antigen-positive patients showed concordant results with the two assays. The HCII assay was more sensitive than the bDNA assay by 1 dilution, with the lowest reading being 0.9 pg/ml (3.8 pg/ml by bDNA assay). The HBV DNA seropositivity rates for the 102 samples were 58, 67, and 97% by bDNA, HCII, and nested PCR, respectively. While the relationship between results obtained with the bDNA assay and those with the HCII assay was nonlinear, with the bDNA assay yielding values 2.83 +/- 0.92-fold higher than those of the HCII assay, especially at high HBV DNA levels, a linear relationship was observed between the two sets of data after logarithmic conversion. The formula for interassay conversion of results was derived as follows: HBV DNA by HCII (picograms per milliliter) = 3.19 x [HBV DNA by bDNA (megaequivalents per milliliter)](0.866). The HCII assay was technically less complex and required a shorter assay time (4 h) than the bDNA assay (24 h). We conclude that the HCII assay compares favorably with the bDNA assay and offers the additional advantages of increased sensitivity and shorter assay time. The increased sensitivity should be particularly useful in monitoring the efficacy of antiviral therapies and detecting the emergence of drug-resistant HBV mutants.
Application of a fluorometric microplate algal toxicity assay for riverine periphytic algal species.
Nagai, Takashi; Taya, Kiyoshi; Annoh, Hirochica; Ishihara, Satoru
2013-08-01
Although riverine periphytic algae attached to riverbed gravel are dominant species in flowing rivers, there is limited toxicity data on them because of the difficulty in cell culture and assays. Moreover, it is well known that sensitivity to pesticides differ markedly among species, and therefore the toxicity data for multiple species need to be efficiently obtained. In this study, we investigated the use of fluorometric microplate toxicity assay for testing periphytic algal species. We selected five candidate test algal species Desmodesmus subspicatus, Achnanthidium minutissimum, Navicula pelliculosa, Nitzschia palea, and Pseudanabaena galeata. The selected species are dominant in the river, include a wide range of taxon, and represent actual species composition. Other additional species were also used to compare the sensitivity and suitability of the microplate assay. A 96-well microplate was used as a test chamber and algal growth was measured by in-vivo fluorescence. Assay conditions using microplate and fluorometric measurement were established, and sensitivities of 3,5-dichlorophenol as a reference substance were assayed. The 50 percent effect concentrations (EC50s) obtained by fluorometric microplate assay and those obtained by conventional Erlenmeyer flask assay conducted in this study were consistent. Moreover, the EC50 values of 3,5-dichlorophenol were within the reported confidence intervals in literature. These results supported the validity of our microplate assay. Species sensitivity distribution (SSD) analysis was conducted using the EC50s of five species. The SSD was found to be similar to the SSD obtained using additional tested species, suggesting that SSD using the five species largely represents algal sensitivity. Our results provide a useful and efficient method for high-tier probabilistic ecological risk assessment of pesticides. Copyright © 2013 Elsevier Inc. All rights reserved.
Soltan, Mohamed A; Tsai, Yun-Long; Lee, Pei-Yu A; Tsai, Chuan-Fu; Chang, Hsiao-Fen G; Wang, Hwa-Tang T; Wilkes, Rebecca P
2016-09-01
There is no gold standard for detection of Rotavirus Group A (RVA), one of the main causes of diarrhea in neonatal animals. Sensitive and specific real-time RT-PCR (rtRT-PCR) assays are available for RVA but require submission of the clinical samples to diagnostic laboratories. Patient-side immunoassays for RVA protein detection have shown variable results, particularly with samples from unintended species. A sensitive and specific test for detection of RVA on the farm would facilitate rapid management decisions. The insulated isothermal RT-PCR (RT-iiPCR) assay works in a portable machine to allow sensitive and specific on-site testing. The aim of this investigation was to evaluate a commercially available RT-iiPCR assay for RVA detection in feces from different animal species. This assay was compared to an in-house rtRT-PCR assay and a commercially available rtRT-PCR kit, as well as an ELISA and EM for RVA detection. All three PCR assays targeted the well-conserved NSP5 gene. Clinical fecal samples from 108 diarrheic animals (mainly cattle and horses) were tested. The percentage of positive samples by ELISA, EM, in-house rtRT-PCR, commercial rtRT-PCR, and RT-iiPCR was 29.4%, 31%, 36.7%, 51.4%, 56.9%, respectively. The agreement between different assays was high (81.3-100%) in samples containing high viral loads. The sensitivity of the RT-iiPCR assay appeared to be higher than the commercially available rtRT-PCR assay, with a limit of detection (95% confidence index) of 3-4 copies of in vitro transcribed dsRNA. In conclusion, the user-friendly, field-deployable RT-iiPCR system holds substantial promise for on-site detection of RVA. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Claus, C; Bergs, S; Emmrich, N C; Hübschen, J M; Mankertz, A; Liebert, U G
2017-02-01
Although teratogenic rubella virus (RV) causes a vaccine-preventable disease, it is still endemic in several countries worldwide. Thus, there is a constant risk of RV importation into non-endemic areas. RV monitoring, especially during measles and Zika virus outbreaks, requires reliable diagnostic tools. For this study, a TaqMan-based one-step reverse transcription-quantitative PCR (RT-qPCR) assay, with the p90 gene as a novel and so far unexplored target for detection of clade I and II genotypes, was developed and evaluated. Automated nucleic acid extraction was carried out. Performance characteristics of the TaqMan RT-qPCR assay were determined for a RV plasmid standard and RNA extracted from virus-infected cell culture supernatants representing clade I and II genotypes. Diagnostic specificity and sensitivity were validated against other RNA and DNA viruses, relevant for RV diagnostic approaches and for RV-positive clinical samples, respectively. The assay is specific and highly sensitive with a limit of detection as low as five to one copies per reaction or 200 infectious virus particles per ml. The coefficients of variation (CV) were specified as intra- (within one run) and inter- (between different runs) assay variation, and calculated based on the standard deviations for the obtained Ct values of the respective samples. Intra- and inter-assay CV values were low, with a maximum of 3.4% and 2.4%, respectively. The assay was shown to be suitable and specific for the analysis of clinical samples. With p90 as a novel target, the highly sensitive and specific TaqMan assay outlined in this study is suitable for RV diagnosis worldwide.
Houmami, Nawal El; Durand, Guillaume André; Bzdrenga, Janek; Darmon, Anne; Minodier, Philippe; Seligmann, Hervé; Raoult, Didier; Fournier, Pierre-Edouard
2018-06-06
Kingella kingae is a significant pediatric pathogen responsible for bone and joint infections, occult bacteremia, and endocarditis in early childhood. Past efforts to detect this bacterium by culture and broad-range 16S rRNA gene polymerase chain reaction (PCR) assays from clinical specimens have proven unsatisfactory and were gradually let out for the benefit of specific real-time PCR tests targeting the groEL gene and RTX locus of K. kingae by the late 2000s. However, recent studies showed that real-time PCR (RT-PCR) assays targeting the Kingella sp. RTX locus that are currently available for the diagnosis of K. kingae infection lack of specificity because they could not distinguish between K. kingae and the recently described K. negevensis species. Furthermore, in silico analysis of the groEL gene from a large collection of 45 K. kingae strains showed that primers and probes from K. kingae groEL -based RT-PCR assays display a few mismatches with K. kingae groEL variations that may result in a decreased detection sensitivity, especially in paucibacillary clinical specimens. In order to provide an alternative to groEL - and RTX-targeting RT-PCR assays that may suffer from suboptimal specificity and sensitivity, a K. kingae -specific RT-PCR assay targeting the malate dehydrogenase ( mdh ) gene was developed for predicting no mismatch against 18 variants of the K. kingae mdh gene from 20 distinct sequences types of K. kingae This novel K. kingae -specific RT-PCR assay demonstrated a high specificity and sensitivity and was successfully used to diagnose K. kingae infections and carriage in 104 clinical specimens from children aged between 7 months and 7 years old. Copyright © 2018 American Society for Microbiology.
Shankar, Manoharan; Priyadharshini, Ramachandran; Gunasekaran, Paramasamy
2009-08-01
An image analysis-based method for high throughput screening of an alpha-amylase mutant library using chromogenic assays was developed. Assays were performed in microplates and high resolution images of the assay plates were read using the Virtual Microplate Reader (VMR) script to quantify the concentration of the chromogen. This method is fast and sensitive in quantifying 0.025-0.3 mg starch/ml as well as 0.05-0.75 mg glucose/ml. It was also an effective screening method for improved alpha-amylase activity with a coefficient of variance of 18%.
Molecular diagnosis of lyssaviruses and sequence comparison of Australian bat lyssavirus samples.
Foord, A J; Heine, H G; Pritchard, L I; Lunt, R A; Newberry, K M; Rootes, C L; Boyle, D B
2006-07-01
To evaluate and implement molecular diagnostic tests for the detection of lyssaviruses in Australia. A published hemi-nested reverse transcriptase polymerase chain reaction (RT-PCR) for the detection of all lyssavirus genotypes was modified to a fully nested RT-PCR format and compared with the original assay. TaqMan assays for the detection of Australian bat lyssavirus (ABLV) were compared with both the nested and hemi-nested RT-PCR assays. The sequences of RT-PCR products were determined to assess sequence variations of the target region (nucleocapsid gene) in samples of ABLV originating from different regions. The nested RT-PCR assay was highly analytically specific, and at least as analytically sensitive as the hemi-nested assay. The TaqMan assays were highly analytically specific and more analytically sensitive than either RT-PCR assay, with a detection level of approximately 10 genome equivalents per microl. Sequence of the first 544 nucleotides of the nucleocapsid protein coding sequence was obtained from all samples of ABLV received at Australian Animal Health Laboratory during the study period. The nested RT-PCR provided a means for molecular diagnosis of all tested genotypes of lyssavirus including classical rabies virus and Australian bat lyssavirus. The published TaqMan assay proved to be superior to the RT-PCR assays for the detection of ABLV in terms of analytical sensitivity. The TaqMan assay would also be faster and cross contamination is less likely. Nucleotide sequence analyses of samples of ABLV from a wide geographical range in Australia demonstrated the conserved nature of this region of the genome and therefore the suitability of this region for molecular diagnosis.
Flores-Chavez, Maria Delmans; Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard
2018-05-01
Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi , for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% ( n = 674). Overall relative specificities were 99.90% ( n = 14,681), 100% ( n = 313), and 100% ( n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% ( n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. Copyright © 2018 Flores-Chavez et al.
Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard
2018-01-01
ABSTRACT Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi, for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% (n = 674). Overall relative specificities were 99.90% (n = 14,681), 100% (n = 313), and 100% (n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% (n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. PMID:29444836
Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin
2018-03-28
Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target <0.5 log. Qualitative assay results for 159 clinical samples showed good concordance (88.1%; κ=0.75; 95% confidence interval: 0.651-0.845). For the 106 samples quantitated by both assays, viral load results were highly correlated (R=0.92) and differed on average by 0.09 log, with 95.3% of the samples being within the 95% limit of agreement of the assays. Linearity for viral loads 1-7 log was excellent for both assays (R2>0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.
A novel assay for monoacylglycerol hydrolysis suitable for high-throughput screening.
Brengdahl, Johan; Fowler, Christopher J
2006-12-01
A simple assay for monoacylglycerol hydrolysis suitable for high-throughput screening is described. The assay uses [(3)H]2-oleoylglycerol as substrate, with the tritium label in the glycerol part of the molecule and the use of phenyl sepharose gel to separate the hydrolyzed product ([(3)H]glycerol) from substrate. Using cytosolic fractions derived from rat cerebella as a source of hydrolytic activity, the assay gives the appropriate pH profile and sensitivity to inhibition with compounds known to inhibit hydrolysis of this substrate. The assay could also be adapted to a 96-well plate format, using C6 cells as the source of hydrolytic activity. Thus the assay is simple and appropriate for high-throughput screening of inhibitors of monoacylglycerol hydrolysis.
Avonto, Cristina; Chittiboyina, Amar G; Rua, Diego; Khan, Ikhlas A
2015-12-01
Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, 'HTS-DCYA assay', is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. Copyright © 2015 Elsevier Inc. All rights reserved.
Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.
Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S
2016-02-01
Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.
Gimferrer, Laura; Andrés, Cristina; Rando, Ariadna; Piñana, Maria; Codina, Maria Gema; Martin, Maria Del Carmen; Fuentes, Francisco; Rubio, Susana; Alcubilla, Pilar; Pumarola, Tomàs; Antón, Andrés
2018-05-25
Influenza (FLUV) and human respiratory syncytial (HRSV) viruses are etiological agents of respiratory infections that cause a significant morbidity and mortality worldwide. A rapid and accurate diagnosis of these respiratory viruses is essential for an appropriate patient management. Molecular tests are the best detection option due to their high sensitivity and specificity. Seegene's Allplex™ Respiratory Panel 1 (Allplex RP1) is a real-time one-step RT-PCR assay for the simultaneous detection of FLUAV, FLUBV, HRSV-A and HRSV-B. In addition, it allows the determination of FLUAV subtype (H1, H3 and H1pdm09). This study aims to evaluate Allplex RP1 as a rapid molecular test for the detection of FLUAV, FLUBV, HRSV-A and HRSV-B viruses. The Allplex RP1 assay will be compared with other two commercial molecular assays, Prodesse ProFlu+ and ProFAST+ (Hologic, Madison, WI, USA), and GeneXpert Flu/RSV XC (Cepheid, USA). Allplex RP1, ProFlu+ and GeneXpert tests showed 95%, 91% and 96% of accuracy; and 94%, 88% and 95% of sensitivity, respectively. Moreover, Allplex RP1 showed a FLUAV subtype sensitivity of 91% and 88% for FLUAV-H1pdm09 and FLUAV-H3 respectively, and ProFAST+ assay showed sensitivities of 100% for both targets. The three assays showed a 100% of specificity and PPV, while the NPV were 84%, 73% and 86% for Allplex RP1, Prodesse and GeneXpert, respectively. In this study, Seegene's Allplex RP1 assay showed to be highly sensitive, specific, and suitable for detection of FLUV and HRSV, including FLUAV subtyping. In addition, it is also a hands-on-time saving assay due to the automated nucleic acid extraction and PCR setup. Copyright © 2018. Published by Elsevier B.V.
Targeting Conserved Genes in Fusarium Species.
Gil-Serna, Jéssica; Patiño, Belén; Jurado, Miguel; Mirete, Salvador; Vázquez, Covadonga; González-Jaén, M Teresa
2017-01-01
Fumonisins are important mycotoxins contaminating foods and feeds which are mainly produced by F. verticillioides and F. proliferatum. Additionally, both are pathogens of maize and other cereals. We describe two highly sensitive, rapid, and species-specific PCR protocols which enable detection and discrimination of these closely related species in cereal flour or grain samples. The specific primer pairs of these assays were based on the intergenic spacer region of the multicopy rDNA unit which highly improves the sensitivity of the PCR assay in comparison with single-copy target regions.
Fun, Axel; Mok, Hoi Ping; Wills, Mark R; Lever, Andrew M
2017-02-24
Cure of Human Immunodeficiency Virus (HIV) infection remains elusive due to the persistence of HIV in a latent reservoir. Strategies to eradicate latent infection can only be evaluated with robust, sensitive and specific assays to quantitate reactivatable latent virus. We have taken the standard peripheral blood mononuclear cell (PBMC) based viral outgrowth methodology and from it created a logistically simpler and more highly reproducible assay to quantify replication-competent latent HIV in resting CD4 + T cells, both increasing accuracy and decreasing cost and labour. Purification of resting CD4 + T cells from whole PBMC is expedited and achieved in 3 hours, less than half the time of conventional protocols. Our indicator cell line, SupT1-CCR5 cells (a clonal cell line expressing CD4, CXCR4 and CCR5) provides a readily available standardised readout. Reproducibility compares favourably to other published assays but with reduced cost, labour and assay heterogeneity without compromising sensitivity.
Yang, Jin-Long; Cheng, An-Chun; Wang, Ming-Shu; Pan, Kang-Cheng; Li, Min; Guo, Yu-Fei; Li, Chuan-Feng; Zhu, De-Kang; Chen, Xiao-Yue
2009-01-01
Background Goose parvovirus (GPV) is a Dependovirus associated with latent infection and mortality in geese. Currently, it severely affects geese production worldwide. The objective of this study was to develop a fluorescent quantitative real-time polymerase chain reaction (PCR) (FQ-PCR) assay for fast and accurate quantification of GPV DNA in infected goslings, which can aid in the understanding of the regular distribution pattern and the nosogenesis of GPV in vivo. Results The detection limit of the assay was 2.8 × 101 standard DNA copies, with a sensitivity of 3 logs higher than that of the conventional gel-based PCR assay targeting the same gene. The real-time PCR was reproducible, as shown by satisfactory low intraassay and interassay coefficients of variation. Conclusion The high sensitivity, specificity, simplicity, and reproducibility of the GPV fluorogenic PCR assay, combined with a high throughput, make this method suitable for a broad spectrum of GPV etiology-related applications. PMID:19754946
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hornemann, Andrea, E-mail: andrea.hornemann@ptb.de; Hoehl, Arne, E-mail: arne.hoehl@ptb.de; Ulm, Gerhard, E-mail: gerhard.ulm@ptb.de
Bio-diagnostic assays of high complexity rely on nanoscaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. High throughput performance requires the simultaneous detection of various analytes combined with appropriate bioassay components. Nanoparticle induced sensitivity enhancement, and subsequent multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are fitting well these purposes. SEIRA constitutes an ideal platform to isolate the vibrational signatures of targeted bioassay and active molecules. The potential of several targeted biolabels, here fluorophore-labeled antibody conjugates, chemisorbed onto low-cost biocompatible gold nano-aggregates substrates have been explored for their use in assay platforms. Dried films were analyzedmore » by synchrotron radiation based FTIR/SEIRA spectro-microscopy and the resulting complex hyperspectral datasets were submitted to automated statistical analysis, namely Principal Components Analysis (PCA). The relationships between molecular fingerprints were put in evidence to highlight their spectral discrimination capabilities. We demonstrate that robust spectral encoding via SEIRA fingerprints opens up new opportunities for fast, reliable and multiplexed high-end screening not only in biodiagnostics but also in vitro biochemical imaging.« less
Chao, Jie; Li, Zhenhua; Li, Jing; Peng, Hongzhen; Su, Shao; Li, Qian; Zhu, Changfeng; Zuo, Xiaolei; Song, Shiping; Wang, Lianhui; Wang, Lihua
2016-07-15
Microarrays of biomolecules hold great promise in the fields of genomics, proteomics, and clinical assays on account of their remarkably parallel and high-throughput assay capability. However, the fluorescence detection used in most conventional DNA microarrays is still limited by sensitivity. In this study, we have demonstrated a novel universal and highly sensitive platform for fluorescent detection of sequence specific DNA at the femtomolar level by combining dextran-coated microarrays with hybridization chain reaction (HCR) signal amplification. Three-dimensional dextran matrix was covalently coated on glass surface as the scaffold to immobilize DNA recognition probes to increase the surface binding capacity and accessibility. DNA nanowire tentacles were formed on the matrix surface for efficient signal amplification by capturing multiple fluorescent molecules in a highly ordered way. By quantifying microscopic fluorescent signals, the synergetic effects of dextran and HCR greatly improved sensitivity of DNA microarrays, with a detection limit of 10fM (1×10(5) molecules). This detection assay could recognize one-base mismatch with fluorescence signals dropped down to ~20%. This cost-effective microarray platform also worked well with samples in serum and thus shows great potential for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Yang; Qin, Xiaodong; Zhang, Xiangle; Zhao, Zhixun; Zhang, Wei; Zhu, Xueliang; Cong, Guozheng; Li, Yanmin; Zhang, Zhidong
2017-07-17
Goatpox virus (GTPV) and sheeppox virus (SPPV), which belong to the Capripoxvirus (CaPV), are economically important pathogens of small ruminants. Therefore, a sensitive, specific and rapid diagnostic assay for detection of GTPV and SPPV is necessary to accurately and promptly control these diseases. Recombinase polymerase amplification (RPA) assays combined with a real-time fluorescent detection (real-time RPA assay) and lateral flow dipstick (RPA LFD assay) were developed targeting the CaPV G-protein-coupled chemokine receptor (GPCR) gene, respectively. The sensitivity of both CaPV real-time RPA assay and CaPV RPA LFD assay were 3 × 10 2 copies per reaction within 20 min at 38 °C. Both assays were highly specific for CaPV, with no cross-reactions with peste des petits ruminants virus, foot-and-mouth disease virus and Orf virus. The evaluation of the performance of these two assays with clinical sample (n = 107) showed that the CaPV real-time RPA assay and CaPV RPA LFD assay were able to specially detect SPPV or GTPV present in samples of ovine in liver, lung, kidney, spleen, skin and blood. This study provided a highly time-efficient and simple alternative for rapid detection of GTPV and SPPV.
Danilova, Ludmila; Anagnostou, Valsamo; Caushi, Justina X; Sidhom, John-William; Guo, Haidan; Chan, Hok Yee; Suri, Prerna; Tam, Ada J; Zhang, Jiajia; El Asmar, Margueritta; Marrone, Kristen A; Naidoo, Jarushka; Brahmer, Julie R; Forde, Patrick M; Baras, Alexander S; Cope, Leslie; Velculescu, Victor E; Pardoll, Drew; Housseau, Franck; Smith, Kellie N
2018-06-12
Mutation-associated neoantigens (MANAs) are a target of antitumor T-cell immunity. Sensitive, simple, and standardized assays are needed to assess the repertoire of functional MANA-specific T cells in oncology. Assays analyzing in vitro cytokine production such as ELISpot and intracellular cytokine staining (ICS) have been useful but have limited sensitivity in assessing tumor-specific T-cell responses and do not analyze antigen-specific T-cell repertoires. The FEST (Functional Expansion of Specific T cells) assay described herein integrates TCR sequencing of short-term, peptide-stimulated cultures with a bioinformatic platform to identify antigen-specific clonotypic amplifications. This assay can be adapted for all types of antigens, including mutation associated neoantigens (MANAs) via tumor exome-guided prediction of MANAs. Following in vitro identification by the MANAFEST assay, the MANA-specific CDR3 sequence can be used as a molecular barcode to detect and monitor the dynamics of these clonotypes in blood, tumor, and normal tissue of patients receiving immunotherapy. MANAFEST is compatible with high-throughput routine clinical and lab practices. Copyright ©2018, American Association for Cancer Research.
Kang, Kang; Zhang, Xiaoying; Liu, Hongtao; Wang, Zhiwei; Zhong, Jiasheng; Huang, Zhenting; Peng, Xiao; Zeng, Yan; Wang, Yuna; Yang, Yi; Luo, Jun; Gou, Deming
2012-01-01
Background MicroRNAs (miRNAs) are small, non-coding RNAs capable of postranscriptionally regulating gene expression. Accurate expression profiling is crucial for understanding the biological roles of miRNAs, and exploring them as biomarkers of diseases. Methodology/Principal Findings A novel, highly sensitive, and reliable miRNA quantification approach,termed S-Poly(T) miRNA assay, is designed. In this assay, miRNAs are subjected to polyadenylation and reverse transcription with a S-Poly(T) primer that contains a universal reverse primer, a universal Taqman probe, an oligo(dT)11 sequence and six miRNA-specific bases. Individual miRNAs are then amplified by a specific forward primer and a universal reverse primer, and the PCR products are detected by a universal Taqman probe. The S-Poly(T) assay showed a minimum of 4-fold increase in sensitivity as compared with the stem-loop or poly(A)-based methods. A remarkable specificity in discriminating among miRNAs with high sequence similarity was also obtained with this approach. Using this method, we profiled miRNAs in human pulmonary arterial smooth muscle cells (HPASMC) and identified 9 differentially expressed miRNAs associated with hypoxia treatment. Due to its outstanding sensitivity, the number of circulating miRNAs from normal human serum was significantly expanded from 368 to 518. Conclusions/Significance With excellent sensitivity, specificity, and high-throughput, the S-Poly(T) method provides a powerful tool for miRNAs quantification and identification of tissue- or disease-specific miRNA biomarkers. PMID:23152780
Alvarez-Moya, C; Santerre-Lucas, A; Zúñiga-González, G; Torres-Bugarín, O; Padilla-Camberos, E; Feria-Velasco, A
2001-01-01
To assess the genotoxic activity of N-nitroso diethylamine (NDEA), maleic hydrazide (MH), and ethyl methane sulfonate (EMS) using two systems: the comet assay on nuclei from Tradescantia, and the pink mutation test on Tradescantia staminal hairs (clone 4430). Tradescantia cups was obtained from Laboratorio de Citogenética y Mutagénesis del Centro de Ciencias de la Atmósfera de la Universidad Nacional Autónoma de México and treated with: N-nitroso diethylamine (NDEA) at 1, 5, 10 mM, maleic hydrazide (MH) at 1, 5, 10 mM and ethyl methane sulfonate (EMS) at 15, 30 and 45 mM; and used in both pink mutation assay and comet assay using cellular nuclei from Tradescantia staminal hairs. The observation of staminal hair was realized along eight days (6-14) after treatment), flowers produced day 14 after treatment were utilized done according to Underbrink. In previous reports on plants, were comet assay was used, breaking cellular wall and separating by centrifugation gradient are necessary. Here, nuclei from staminal hairs were obtained by squashing the cells (is not necessary to utilize to break special procedure cellular wall), collected using a nylon mesh of 80 Mm and next the comet assay was applied. Student's T test was the statistical test used for analyzing the comet assay data. Both assays showed a great sensitivity to the studied mutagens. A relationship between the dose-pink event and the dose-tail length was evident. Even though the Tradescantia mutation assay is a sensitive test with MH and EMS, low doses of NDEA were not able to induce a significant increase in the pink event frequencies; however, the comet assay was able to detect the mutagenic effect of NDEA at the same dose. Thus, it is clear that the comet assay is highly sensitive to the lowest dose of chemical mutagens. The comet assay on nuclei from Tradescantia staminal hairs is a useful tool to monitor genotoxic agents; it is simple, highly sensitive, and faster than the pink mutation test.
Zheng, Jianyong; Wei, Wei; Lan, Xing; Zhang, Yinjun; Wang, Zhao
2018-05-15
This study describes a sensitive and fluorescent microplate assay method to detect lipase transesterification activity. Lipase-catalyzed transesterification between butyryl 4-methyl umbelliferone (Bu-4-Mu) and methanol in tert-butanol was selected as the model reaction. The release of 4-methylumbelliferone (4-Mu) in the reaction was determined by detecting the fluorescence intensity at λ ex 330 nm and λ em 390 nm. Several lipases were used to investigate the accuracy and efficiency of the proposed method. Apparent Michaelis constant (Km) was calculated for transesterification between Bu-4-Mu and methanol by the lipases. The main advantages of the assay method include high sensitivity, inexpensive reagents, and simple detection process. Copyright © 2018 Elsevier Inc. All rights reserved.
Designing novel nano-immunoassays: antibody orientation versus sensitivity
NASA Astrophysics Data System (ADS)
Puertas, S.; Moros, M.; Fernández-Pacheco, R.; Ibarra, M. R.; Grazú, V.; de la Fuente, J. M.
2010-12-01
There is a growing interest in the use of magnetic nanoparticles (MNPs) for their application in quantitative and highly sensitive biosensors. Their use as labels of biological recognition events and their detection by means of some magnetic method constitute a very promising strategy for quantitative high-sensitive lateral-flow assays. In this paper, we report the importance of nanoparticle functionalization for the improvement of sensitivity for a lateral-flow immunoassay. More precisely, we have found that immobilization of IgG anti-hCG through its polysaccharide moieties on MNPs allows more successful recognition of the hCG hormone. Although we have used the detection of hCG as a model in this work, the strategy of binding antibodies to MNPs through its sugar chains reported here is applicable to other antibodies. It has huge potential as it will be very useful for the development of quantitative and high-sensitive lateral-flow assays for its use on human and veterinary, medicine, food and beverage manufacturing, pharmaceutical, medical biologics and personal care product production, environmental remediation, etc.
Thorn, Mitchell; Hudson, Adam W; Kreeger, John; Kawabe, Thomas T; Bowman, Christopher J; Collinge, Mark
2015-01-01
Delayed-type hypersensitivity (DTH) is a T-cell-mediated immune response that may be used for immunotoxicity testing in non-clinical species. However, in some cases DTH assays using T-dependent antigens may be confounded by the production of antibodies to the antigen. The authors have previously modified a DTH assay, initially validated in the mouse, for use in juvenile rats to assess the effect of immunosuppressive drugs on the developing rat immune system. The assay measures footpad swelling induced by subcutaneous footpad injection of Candida albicans (C. albicans) derived-chitosan in rats previously sensitized with C. albicans. Antibodies to chitosan are not produced in this model. However, considerable inter-animal variability inherent in the footpad swelling assay can make it difficult to precisely quantify the magnitude of the immune response and inhibition by immunosuppressants, particularly if complete suppression is not observed. This report describes the development of an ex vivo assay to assess DTH in rats using interferon (IFN)-γ production by splenocytes, obtained from rats sensitized with C. albicans, as the quantifiable measure of the DTH response. Adult and neonatal rats administered dexamethasone (DEX), a known immunosuppressant, exhibited immunosuppression as evidenced by a reduction in ex vivo IFNγ production from splenocytes challenged with C. albicans-derived chitosan. Current data indicate that the ex vivo based DTH assay is more sensitive than the conventional footpad swelling assay due to a lower background response and the ability to detect a response as early as post-natal day (PND) 12. The ex vivo based rat DTH assay offers a highly sensitive and quantitative alternative to the footpad swelling assay for the assessment of the immunotoxic potential of drugs. The increased sensitivity of the ex vivo DTH assay may be useful for identifying smaller changes in response to immunotoxic drugs, as well as detecting responses earlier in animal development.
New generation QuIC assays for prion seeding activity.
Orrù, Christina D; Wilham, Jason M; Vascellari, Sarah; Hughson, Andrew G; Caughey, Byron
2012-01-01
The ability of abnormal TSE-associated forms of PrP to seed the formation of amyloid fibrils from recombinant PrP(Sen) has served as the basis for several relatively rapid and highly sensitive tests for prion diseases. These tests include rPrP-PMCA (rPMCA), standard quaking-induced conversion (S-QuIC), amyloid seeding assay (ASA), real-time QuIC (RT-QuIC) and enhanced QuIC (eQuIC). Here, we summarize recent improvements in the RT-QuIC-based assays that enhance the practicality, sensitivity and quantitative attributes of assays QuIC and promote the detection of prion seeding activity in dilute, inhibitor-laden fluids such as blood plasma.
Dittmer, W U; de Kievit, P; Prins, M W J; Vissers, J L M; Mersch, M E C; Martens, M F W C
2008-09-30
A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions as well as the bound/free separation are entirely controlled by magnetic forces induced by electromagnets above and below the sensor chip. During the assay, particles conjugated with tracer antibodies are actuated through the sample for target capture, and rapidly brought to the sensor surface where they bind to immobilized capture antibodies. Weakly or unbound labels are removed with a magnetic force oriented away from the GMR sensor surface. For the measurement of parathyroid hormone (PTH), a detection limit in the 10 pM range is obtained with a total assay time of 15 min when 300 nm particles are used. The same sensitivity can be achieved in 5 min when 500 nm particles are used. If 500 nm particles are employed in a 15-minute assay, then 0.8 pM of PTH is detectable. The low sample volume, high analytical performance and high speed of the test coupled with the compact GMR biosensor make the system especially suitable for sensitive testing outside of laboratory environments.
Dunning, F. Mark; Ruge, Daniel R.; Piazza, Timothy M.; Stanker, Larry H.; Zeytin, Füsûn N.
2012-01-01
Rapid, high-throughput assays that detect and quantify botulinum neurotoxin (BoNT) activity in diverse matrices are required for environmental, clinical, pharmaceutical, and food testing. The current standard, the mouse bioassay, is sensitive but is low in throughput and precision. In this study, we present three biochemical assays for the detection and quantification of BoNT serotype A, B, and F proteolytic activities in complex matrices that offer picomolar to femtomolar sensitivity with small assay volumes and total assay times of less than 24 h. These assays consist of magnetic beads conjugated with BoNT serotype-specific antibodies that are used to purify BoNT from complex matrices before the quantification of bound BoNT proteolytic activity using the previously described BoTest reporter substrates. The matrices tested include human serum, whole milk, carrot juice, and baby food, as well as buffers containing common pharmaceutical excipients. The limits of detection were below 1 pM for BoNT/A and BoNT/F and below 10 pM for BoNT/B in most tested matrices using 200-μl samples and as low as 10 fM for BoNT/A with an increased sample volume. Together, these data describe rapid, robust, and high-throughput assays for BoNT detection that are compatible with a wide range of matrices. PMID:22923410
Saravia, Silvia Gilka Muñoz; Haberland, Annekathrin; Bartel, Sabine; Araujo, Raul; Valda, Gregorio; Reynaga, Diana Duchen; Ramirez, Ivan Diaz; Borges, Adrian C; Wallukat, Gerd; Schimke, Ingolf
2011-02-01
Chronic Chagas disease (15 million patients; annual incidence, 40, 000 patients; annual mortality, 12 ,500 patients) is the most serious parasitic disease in Latin America. Between 10 and 30 years after infection, 30% of patients with Chagas disease develop heart injury, which is the main reason for its high mortality. Consequently, frequent cardiac diagnostics are required for patients with Chagas disease. To minimize time-intensive and cost-intensive diagnostics, such as electrocardiography, echocardiography, and radiologic imaging, we tested the effect of measuring serum cardiac troponin T (cTnT) with a highly sensitive assay. To indicate the pathophysiologic background for cTnT release in Chagas heart injury, inflammation markers, such as C-reactive protein and interleukin 6, were measured in parallel. Serum cTnT was measured in 26 healthy subjects and in 179 patients with chronic Chagas disease who were asymptomatic (indeterminate stage, n = 86), who were suffering from cardiomyopathy with or without megacolon (n = 71), or who were suffering from megacolon exclusively (n = 22). Serum cTnT was significantly higher in patients with cardiomyopathy with or without megacolon than in healthy subjects, asymptomatic subjects, and patients with megacolon, and the cTnT value was correlated with the severity of the cardiomyopathy. The lower limit of detection for the highly sensitive assay (3 ng/L) was best at distinguishing patients with, and without, heart injury. C-reactive protein and interleukin 6 were found to parallel cTnT changes in both the different Chagas groups and the cardiomyopathy groups separated by disease severity. Highly sensitive cTnT measurement has the potential to contribute to diagnosis and monitoring of heart injury in patients with chronic Chagas disease. The highly sensitive assay of cTnT release seems to be related to Chagas heart disease-specific inflammation.
Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong
2018-02-08
Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.
2016-01-01
Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468
Tait, Brian D.
2016-01-01
This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10–15 years. This revolution however has created a new paradigm in clinical decision making with respect to the detection of low level pretransplant HLA sensitization and its clinical relevance. The relative sensitivities of the assays used are discussed and the relevance of conflicting inter-assay results. Each assay has its advantages and disadvantages and these are discussed. Over the last decade, the bead-based assay utilizing the Luminex® fluorocytometer instrument has become established as the “gold standard” for HLA antibody testing. However, there are still unresolved issues surrounding this technique, such as the presence of denatured HLA molecules on the beads which reveal cryptic epitopes and the issue of appropriate fluorescence cut off values for positivity. The assay has been modified to detect complement binding (CB) in addition to non-complement binding (NCB) HLA antibodies although the clinical relevance of the CB and NCB IgG isotypes is not fully resolved. The increase sensitivity of the Luminex® bead assay over the complement-dependent cytotoxicity crossmatch has permitted the concept of the “virtual crossmatch” whereby the crossmatch is predicted to a high degree of accuracy based on the HLA antibody specificities detected by the solid phase assay. Dialog between clinicians and laboratory staff on an individual patient basis is essential for correct clinical decision making based on HLA antibody results obtained by the various techniques. PMID:28018342
Verma, Sandeep; Singh, Ruchi; Sharma, Vanila; Bumb, Ram Avtar; Negi, Narendra Singh; Ramesh, V; Salotra, Poonam
2017-03-23
Leishmaniasis is a spectrum of diseases with great relevance to public health. Conventional diagnostic methods are time consuming, needing trained personnel. A robust, rapid and cost effective diagnostic test is warranted for on-time diagnosis and field application. We have developed a loop mediated isothermal amplification (LAMP) assay with primers (n = 6) based on Leishmania donovani kDNA for detection of Leishmania infection, using a closed tube to prevent cross-contamination. The assay was used to detect Leishmania infection in biological samples obtained from patients of visceral leishmaniasis (VL), post kala-azar dermal leishmaniasis (PKDL) and cutaneous leishmaniasis (CL). The assay was positive for L. donovani, L. tropica and L. major parasites, with the highest sensitivity towards L. donovani (1 fg DNA). The high sensitivity of the assay for detection of L. donovani was reflected in its ability to detect parasite DNA within 30 min of amplification time with a threshold detection limit of ≥25 copies per reaction. The assay detected parasite in 64 of 66 VL blood samples (sensitivity, 96.9%; 95% CI: 89.6-99.2%), 15 of 15 VL bone marrow aspirate samples (sensitivity, 100%; 95% CI:79.6-100%), 65 of 67 PKDL tissue biopsy samples (sensitivity, 97%; 95% CI:89.7-99.2%). The assay was evaluated in a few cases of CL wherein it was found positive in 8 of 10 tissue biopsies (sensitivity, 80%; 95% CI: 49-94.3%). The assay was negative in all control blood (n = 76) and tissue biopsy (n = 24) samples (specificity, 100%; 95% CI: 96.3-100%). Further, the assay was evaluated for its utility in assessment of cure in treated VL and PKDL patients. The assay detected parasite DNA in 2 of 20VL blood samples and 2 of 21 PKDL tissue samples. Out of 4 cases that were positive for parasite DNA at post treatment stage, 2 patients (1VL and 1 PKDL) returned with relapse. The study demonstrated a Leishmania genus specific closed tube LAMP assay for reliable and rapid molecular diagnosis of VL and PKDL with potential for application in assessment of cure.
Kumvongpin, Ratchanida; Jearanaikool, Patcharee; Wilailuckana, Chotechana; Sae-Ung, Nattaya; Prasongdee, Prinya; Daduang, Sakda; Wongsena, Metee; Boonsiri, Patcharee; Kiatpathomchai, Wansika; Swangvaree, Sukumarn Sanersak; Sandee, Alisa; Daduang, Jureerut
2016-08-01
High-risk human papillomavirus (HR-HPV) causes cervical cancer. HPV16 and HPV18 are the most prevalent strains of the virus reported in women worldwide. Loop-mediated isothermal amplification (LAMP) is an alternative method for DNA detection under isothermal conditions. However, it results in a turbid amplified product which is not easily detected by the naked eye. This study aimed to develop an improved technique by using gold nanoparticles (AuNPs) attached to a single-stranded DNA probe for the detection of HPV16 and HPV18. Detection of the LAMP product by AuNP color change was compared with detection by visual turbidity. The optimal conditions for this new LAMP-AuNP assay were an incubation time of 20min and a temperature of 65°C. After LAMP amplification was complete, its products were hybridized with the AuNP probe for 5min and then detected by the addition of magnesium salt. The color changed from red to blue as a result of aggregation of the AuNP probe under high ionic strength conditions produced by the addition of the salt. The sensitivity of the LAMP-AuNP assay was greater than the LAMP turbidity assay by up to 10-fold for both HPV genotypes. The LAMP-AuNP assay showed higher sensitivity and ease of visualization than did the LAMP turbidity for the detection of HPV16 and HPV18. Additionally, AuNP-HPV16 and AuNP-HPV18 probes were stable for over 1year. The combination of LAMP and the AuNP-probe colorimetric assay offers a simple, rapid and highly sensitive alternative diagnostic tool for the detection of HPV16 and HPV18 in district hospitals or field studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Bil-Lula, Iwona; Matuszek, Patryk; Pfeiffer, Thomas; Woźniak, Mieczysław
2015-01-01
Infections of Borrelia burgdorferi sensu lato reveal clinical manifestations affecting numerous organs and tissues. The standard diagnostic procedure of these infections is quite simple if a positive history of tick exposure or typical erythema migrans appears. Lack of unequivocal clinical symptoms creates the necessity for further evaluation with laboratory tests. This study discusses the utility of a novel, improved, well-optimized, sensitive and highly specific quantitative real-time PCR assay for the diagnostics of infections caused by Borrelia burgdorferi sensu lato. We designed an improved, specific, highly sensitive real-time quantitative polymerase chain reaction (RQ-PCR) assay for the detection and quantification of all Borrelia burgdorferi genotypes. A wide validation effort was undertaken to ensure confidence in the highly sensitive and specific detection of B. burgdorferi. Due to high sensitivity and great specificity, as low as 1.6×10² copies of Borrelia per mL of whole blood could be detected. As much as 12 (3%) negative ELISA IgM results, 14 (2.8%) negative results of Line blot IgM, 11 (3.1%) and 7 (2.7%) of negative ELISA IgG and Line blot IgG results, respectively, were positive in real-time PCR. The data in this study confirms the high positive predictive value of real-time PCR test in the detection of Borrelia infections.
Whitehouse, Chris A.; Chase, Kitty; Embers, Monica E.; Kulesh, David A.; Ladner, Jason T.; Palacios, Gustavo F.; Minogue, Timothy D.
2016-01-01
Background Moraxella macacae is a recently described bacterial pathogen that causes epistaxis or so-called bloody nose syndrome in captive macaques. The aim of this study was to develop specific molecular diagnostic assays for M. macacae and to determine their performance characteristics. Methods We developed six real-time PCR assays on the Roche LightCycler. The accuracy, precision, selectivity, and limit of detection (LOD) were determined for each assay, in addition to further validation by testing nasal swabs from macaques presenting with epistaxis at the Tulane National Primate Research Center. Results All assays exhibited 100% specificity and were highly sensitive with an LOD of 10 fg for chromosomal assays and 1 fg for the plasmid assay. Testing of nasal swabs from 10 symptomatic macaques confirmed the presence of M. macacae in these animals. Conclusions We developed several accurate, sensitive, and species-specific real-time PCR assays for the detection of M. macacae in captive macaques. PMID:26365904
Salonen, E M; Miettinen, A; Walle, T K; Koskenmies, S; Kere, J; Julkunen, H
2004-10-01
To investigate the prevalence and diagnostic significance of antibodies against telomeric DNA in systemic lupus erythematosus (SLE) and other autoimmune rheumatic diseases, and to make comparisons with five conventional anti-DNA or anti-nuclear antibody (ANA) assays. Antibodies to telomeres, which are highly repetitive sequences of DNA (TTAGGG/CCCTAA) at the end of eukaryotic chromosomes, were measured by an enzyme linked immunosorbent assay (ELISA) in 305 patients with SLE and 125 patients with other autoimmune rheumatic diseases (78 rheumatoid arthritis, 32 primary Sjögren's syndrome, eight mixed connective tissue disease, seven miscellaneous rheumatic diseases). Other assays used were two commercial ELISA assays for anti-dsDNA using calf thymus as antigen, Crithidialuciliae immunofluorescence, and radioimmunoassay (RIA) for anti-dsDNA and immunofluorescence using Hep-2 cells for ANA. The prevalence of anti-telomere in SLE was 60%, v 5% in rheumatoid arthritis and 18% in other autoimmune rheumatic diseases. Specificity of anti-telomere for SLE was 91%; positive and negative predictive values were 95% and 46%, respectively. For anti-dsDNA by two ELISA assays using calf thymus as antigen, sensitivities were 69% and 29% and specificities 66% and 96%, respectively. Other anti-dsDNA assays had low sensitivities (RIA 43%, Crithidia immunofluorescence 13%). The association of anti-telomere with a history of nephritis in patients with SLE was stronger (p = 0.005) than by any other assay (p = 0.006-0.999). The correlations between the different assays were good (p<0.001 for all comparisons). The new ELISA for anti-telomere antibodies using standardised human dsDNA as antigen is a sensitive and highly specific test for SLE.
NASA Astrophysics Data System (ADS)
Chon, H.; Lee, S.; Wang, R.; Bang, S.-Y.; Lee, H.-S.; Bae, S.-C.; Hong, S. H.; Yoon, Y. H.; Lim, D.; Choo, J.
2015-07-01
We report a highly sensitive anti-cyclic citrullinated peptide (anti-CCP) detection method for early diagnosis of rheumatoid arthritis (RA) using surface-enhanced Raman scattering (SERS)-based immunoassay. Herein, cyclic citrullinated peptide (CCP)-conjugated magnetic beads and anti-human IgG-conjugated hollow gold nanospheres (HGNs) were used as substrates and SERS nano-tags, respectively. First, its detection sensitivity was evaluated using anti-CCP standard solutions. Then quantitative anti-CCP levels, determined by the SERS-based assay, were compared with those obtained from three commercially available anti-CCP assay kits (Immunoscan CCPlus, ImmunnLisa™ CCP and BioPlex™ 2200) to assess its potential utility as a clinical tool. Finally, clinical samples from 20 RA patients were investigated using them. In the SERS-based assay, the anti-CCP level in human serum was successfully determined by monitoring the characteristic Raman peak intensity of SERS nano-tags. The diagnostic performance of our SERS-based immunoassay for clinical samples shows a good agreement with those measured by three commercial anti-CCP kits. In addition, our SERS-based assay results are more consistent in the low concentration range (0-25 U/mL) than those achieved by the commercial kits. Accordingly, it is estimated that the SERS-based assay is a potentially useful diagnostic tool for early diagnosis of RA.
Elsworth, Brendan; Charnaud, Sarah C.; Sanders, Paul R.; Crabb, Brendan S.; Gilson, Paul R.
2014-01-01
Drug discovery is a key part of malaria control and eradication strategies, and could benefit from sensitive and affordable assays to quantify parasite growth and to help identify the targets of potential anti-malarial compounds. Bioluminescence, achieved through expression of exogenous luciferases, is a powerful tool that has been applied in studies of several aspects of parasite biology and high throughput growth assays. We have expressed the new reporter NanoLuc (Nluc) luciferase in Plasmodium falciparum and showed it is at least 100 times brighter than the commonly used firefly luciferase. Nluc brightness was explored as a means to achieve a growth assay with higher sensitivity and lower cost. In addition we attempted to develop other screening assays that may help interrogate libraries of inhibitory compounds for their mechanism of action. To this end parasites were engineered to express Nluc in the cytoplasm, the parasitophorous vacuole that surrounds the intraerythrocytic parasite or exported to the red blood cell cytosol. As proof-of-concept, these parasites were used to develop functional screening assays for quantifying the effects of Brefeldin A, an inhibitor of protein secretion, and Furosemide, an inhibitor of new permeation pathways used by parasites to acquire plasma nutrients. PMID:25392998
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noor, Fozia; Niklas, Jens; Mueller-Vieira, Ursula
2009-06-01
Efficient and accurate safety assessment of compounds is extremely important in the preclinical development of drugs especially when hepatotoxicty is in question. Multiparameter and time resolved assays are expected to greatly improve the prediction of toxicity by assessing complex mechanisms of toxicity. An integrated approach is presented in which Hep G2 cells and primary rat hepatocytes are compared in frequently used cytotoxicity assays for parent compound toxicity. The interassay variability was determined. The cytotoxicity assays were also compared with a reliable alternative time resolved respirometric assay. The set of training compounds consisted of well known hepatotoxins; amiodarone, carbamazepine, clozapine, diclofenac,more » tacrine, troglitazone and verapamil. The sensitivity of both cell systems in each tested assay was determined. Results show that careful selection of assay parameters and inclusion of a kinetic time resolved assay improves prediction for non-metabolism mediated toxicity using Hep G2 cells as indicated by a sensitivity ratio of 1. The drugs with EC{sub 50} values 100 {mu}M or lower were considered toxic. The difference in the sensitivity of the two cell systems to carbamazepine which causes toxicity via reactive metabolites emphasizes the importance of human cell based in-vitro assays. Using the described system, primary rat hepatocytes do not offer advantage over the Hep G2 cells in parent compound toxicity evaluation. Moreover, respiration method is non invasive, highly sensitive and allows following the time course of toxicity. Respiration assay could serve as early indicator of changes that subsequently lead to toxicity.« less
Suehiro, Yutaka; Hashimoto, Shinichi; Higaki, Shingo; Fujii, Ikuei; Suzuki, Chieko; Hoshida, Tomomi; Matsumoto, Toshihiko; Yamaoka, Yuko; Takami, Taro; Sakaida, Isao; Yamasaki, Takahiro
2018-03-30
Although methylated TWIST1 is a biomarker of colorectal neoplasia, its detection from serum samples is very difficult by conventional bisulfite-based methylation assays. Therefore, we have developed a new methylation assay that enables counting of even one copy of a methylated gene in a small DNA sample amount without DNA bisulfite treatment. We performed this study to evaluate the sensitivity and specificity of serum DNA testing by the new methylation assay in combination with and without the fecal immunochemical test for hemoglobin for the detection of colorectal neoplasia. This study comprised 113 patients with colorectal neoplasia and 25 control individuals. For the new methylation assay, DNA was treated in two stages with methylation-sensitive restriction enzymes, followed by measurement of copy numbers of hTERT and methylated TWIST1 by multiplex droplet digital PCR. The fecal immunochemical test had a sensitivity of 8.0% for non-advanced adenoma, 24.3% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 88.0%. The new assay had a sensitivity of 36.0% for non-advanced adenoma, 30.0% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 92.0%. Combination of the both tests increased the sensitivity to 40.0%, 45.7%, and 72.2% for the detection of non-advanced adenoma, advanced adenoma, and colorectal cancer, respectively, and resulted in a specificity of 84.0%. Combination of both tests may provide an alternative screening strategy for colorectal neoplasia including potentially precancerous lesions and colorectal cancer.
Yin, Feifei; Chan, Jasper Fuk-Woo; Zhu, Qixuan; Fu, Ruijia; Chen, Jonathan Hon-Kwan; Choi, Garnet Kwan-Yue; Tee, Kah-Meng; Li, Lihua; Qian, Shiuyun; Yam, Wing-Cheong; Lu, Gang; Yuen, Kwok-Yung
2017-04-01
Rapid and accurate diagnostic assays with simultaneous microbial identification and drug resistance detection are essential for optimising treatment and control of tuberculosis. We developed a novel multiplex (TRIOL, Tuberculosis-Rifampicin-Isoniazid-Ofloxacin-Luminex) assay using the Luminex xMAP system that simultaneously identifies Mycobacterium tuberculosis and detects resistance to first-line and second-line anti-tuberculous drugs, and compared its performance with that by PCR sequencing, using phenotypic drug susceptibility testing as the gold standard. Identification of M. tuberculosis by the TRIOL assay was highly sensitive (100%) and specific (100%). The overall drug-specific specificities were excellent (100%). The overall sensitivity of the TRIOL assay was lower than that of the PCR-sequencing assays (72.4% vs 82.8%) because of a lower sensitivity of detecting rifampicin resistance (71.4% vs 92.9%). The sensitivity of detecting isoniazid and ofloxacin resistance was as good as the PCR-sequencing assays. Importantly, the TRIOL assay did not miss any mutations that were included in the assay. All of the resistant isolates that were missed had uncommon mutations or unknown resistance mechanisms that were not included in the assay. The TRIOL assay has higher throughput, lower cost and is less labour intensive than the PCR-sequencing assays. The TRIOL assay is advantageous in having the capability to detect resistance to multiple drugs and an open-architecture system that allows addition of more specific primers to detect uncommon mutations. Inclusion of additional primers for the identification of non-tuberculous mycobacteria, spoligotyping and improvement of rifampicin resistance detection would enhance the use of the TRIOL assay in future clinical and epidemiological studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Cao, Biyun; Yang, Hong; Song, Juan; Chang, Huafang; Li, Shuqun; Deng, Anping
2013-11-15
The adulteration of food products with melamine has led to an urgent requirement for sensitive, specific, rapid and reliable quantitative/screening methods. To enhance the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) for the detection of melamine in milk, milk powder and feed samples, rational hapten modification and heterogeneous antibody/coating antigen combinations were adopted. Three melamine derivatives with different length of carboxylic spacer at the end were synthesized and linked to carrier proteins for the production of immunogens and coating antigens. Monoclonal antibody against melamine was produced by hybridoma technology. Under optimal experimental conditions, the standard curves of the ELISAs for melamine were constructed in range of 0.1-100 ng mL(-1). The sensitivity was 10-300 times enhanced compared to those in the published literatures. The cross-reactivity values of the ELISAs also demonstrated the assays exhibited high specificity. Five samples were spiked with melamine at different concentrations and detected by the ELISA. The recovery rates of 72.8-123.0% and intra-assay coefficients of variation of 0.8-18.9% (n=3) were obtained. The ELISA for milk sample was confirmed by high-performance liquid chromatography with a high correlation coefficient of 0.9902 (n=6). The proposed ELISA was proven to be a feasible quantitative/screening method for melamine analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Koerbin, Gus; Tate, Jill; Potter, Julia M; Cavanaugh, Juleen; Glasgow, Nicholas; Hickman, Peter E
2012-02-03
Abbott Diagnostics have developed a new highly sensitive troponin I (hs-TnI) assay. We have assessed its analytical characteristics and applied the assay to a population of apparently cardio-healthy persons. We assessed imprecision, bias compared to the previous generation assay, matrix effects, and interferences and applied the assay to an apparently healthy population, deriving the 99th percentile limit of the distribution of values in reference populations for men and women separately. The dynamic range of the assay was ranged from 0.5-50,000 ng/L (pg/mL). The 10% CV was at a concentration of 3.9 ng/L, and the 20% CV was at a concentration of 1.8 ng/L. The new and current version of the TnI assay were highly correlated [slope: 0.98 (95%CI:0.88-1.07), y-intercept:1.20 (95%CI:-2.35-4.75) r²=0.99]. The 99th percentile limit of the distribution of values in a reference population was different for males and females: for males 14.0 ng/L and for females 11.1 ng/L and at these concentrations the assay CV was 5.0%. TnI was detectable in nearly all patient samples from the healthy reference population (98.6%). This new hs-TnI assay is able to measure to an order of magnitude lower than the current generation TnI assay from the same manufacturer. With TnI being detectable in nearly all apparently healthy subject samples this suggests that TnI presence does not always indicate cardiomyocyte necrosis.
Development of duplex real-time PCR for the detection of WSSV and PstDV1 in cultivated shrimp.
Leal, Carlos A G; Carvalho, Alex F; Leite, Rômulo C; Figueiredo, Henrique C P
2014-07-05
The White spot syndrome virus (WSSV) and Penaeus stylirostris penstyldensovirus 1 (previously named Infectious hypodermal and hematopoietic necrosis virus-IHHNV) are two of the most important viral pathogens of penaeid shrimp. Different methods have been applied for diagnosis of these viruses, including Real-time PCR (qPCR) assays. A duplex qPCR method allows the simultaneous detection of two viruses in the same sample, which is more cost-effective than assaying for each virus separately. Currently, an assay for the simultaneous detection of the WSSV and the PstDV1 in shrimp is unavailable. The aim of this study was to develop and standardize a duplex qPCR assay for the simultaneous detection of the WSSV and the PstDV1 in clinical samples of diseased L. vannamei. In addition, to evaluate the performance of two qPCR master mixes with regard to the clinical sensitivity of the qPCR assay, as well as, different methods for qPCR results evaluation. The duplex qPCR assay for detecting WSSV and PstDV1 in clinical samples was successfully standardized. No difference in the amplification of the standard curves was observed between the duplex and singleplex assays. Specificities and sensitivities similar to those of the singleplex assays were obtained using the optimized duplex qPCR. The analytical sensitivities of duplex qPCR were two copies of WSSV control plasmid and 20 copies of PstDV1 control plasmid. The standardized duplex qPCR confirmed the presence of viral DNA in 28 from 43 samples tested. There was no difference for WSSV detection using the two kits and the distinct methods for qPCR results evaluation. High clinical sensitivity for PstDV1 was obtained with TaqMan Universal Master Mix associated with relative threshold evaluation. Three cases of simultaneous infection by the WSSV and the PstDV1 were identified with duplex qPCR. The standardized duplex qPCR was shown to be a robust, highly sensitive, and feasible diagnostic tool for the simultaneous detection of the WSSV and the PstDV1 in whiteleg shrimp. The use of the TaqMan Universal Master Mix and the relative threshold method of data analysis in our duplex qPCR method provided optimal levels of sensitivity and specificity.
Fan, Xiao-Yong; Lü, Guo-Zhen; Wu, Li-Na; Chen, Jing-Hua; Xu, Wen-Qing; Zhao, Chun-Nü; Guo, Sheng-Qi
2006-12-01
Current regulations and recommendations proposed for the production of vaccines in continuous cell lines of any origin demand that these be free of exogenous viruses, particularly retroviruses. Recently, the ultra-sensitive product-enhanced reverse transcriptase (PERT) assay can be used to detect minute of reverse transcriptase (RTase) in single retroviral particle and is 10(6) times more sensitive than the conventional RTase assays. However, coincidental with this increase in sensitivity is an increase in false-positive reactions derived from contaminating cellular DNA polymerases, which are known to have RTase-like activities. To develop a modified single-tube one-step PERT (mSTOS-PERT) assay with improvements on decreasing significantly the level of false-positive reactions, and to evaluate the mSTOS-PERT assay for sensitivity and specificity. Ampliwaxtrade mark was used to compartmentalize the reverse transcription (RT) and PCR step in the same micro-tube with more efficiency and reproducibility, while maintaining the high sensitivity. The DNA amplification products were separated by 2% agarose gel electrophoresis, and then analyzed by non-isotopic Southern blot hybridization. A wide variety of cell lines used in biologicals production were detected to validate the improved mSTOS-PERT assay. The detection limit for the mSTOS-PERT assay was at least 10(-9)U, when using AMV-RTase as a positive control. Furthermore, heparin involvement in the RT step can eliminate completely the false-positive PERT signals which are exhibited by cellular polymerases such as DNA-dependent DNA polymerase alpha, gamma released by cell death. Most mammalian cells (MRC-5, Vero, WISH, 2BS, RK-13, MDCK, etc.) are PERT-negative in cell supernatants. Some PERT-positive signals in cell lysates were found to be introduced by the cellular DNA polymerases and could be inhibited specifically by heparin. Chick cells derived from either chick embryo fibroblasts (CEF) or allantoic fluid from SPF embryonated eggs, murine hybridoma cell SP2/0, etc., contained authentic RTase activities, which could not be inactivated by heparin. The improved mSTOS-PERT assay described here may distinguish the genuine RTase activity from cellular polymerases with high sensitivity and specificity, and is rapid and easy to perform to screen for the possible contamination of minute retroviruses in the cell substrates used in vaccine production.
Adamcova, Michaela; Popelova-Lencova, Olga; Jirkovsky, Eduard; Simko, Fedor; Gersl, Vladimir; Sterba, Martin
2016-01-01
Tn is a unique translational biomarker in cardiology whose potential has not been diminished in the new era of high sensitive assays. cTns can be valuable markers in cardiac diseases as well as in infectious diseases and respiratory diseases. Furthermore, the role of cTns is growing in the routine evaluation of cardioxicity and in determining the efficacy/safety ratio of novel cardioprotective strategies in clinical settings. cTns can detect myocardial injury not only in a wide spectrum of laboratory animals in experimental studies in vivo, but also in isolated heart models or cardiomyocytes in vitro. The crucial issue regarding the cross-species usage of cardiac troponin investigation remains the choice of cardiac troponin testing. This review summarizes the recent proteomic data on aminoacid sequences of cTnT and cTnI in various species, as well as selected analytical characteristics of human cardiac troponin high-sensitivity assays. Due to the highly phylogenetically conserved structure of troponins, the same bioindicator can be investigated using the same method in both clinical and experimental cardiology, thus contributing to a better understanding of the pathogenesis of cardiac diseases as well as to increased effectiveness of troponin use in clinical practice. Measuring cardiac troponins using commercially available human high-sensitivity cardiac troponin tests with convenient antibodies selected on the basis of adequate proteomic knowledge can solve many issues which would otherwise be difficult to address in clinical settings for various ethical and practical reasons. Our survey could help elaborate the practical guidelines for optimizing the choice of cTns assay in cardiology. © 2016 International Union of Biochemistry and Molecular Biology.
Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna
2014-11-01
International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.
Song, Linan; Lachno, D Richard; Hanlon, David; Shepro, Adam; Jeromin, Andreas; Gemani, Dipika; Talbot, Jayne A; Racke, Margaret M; Dage, Jeffrey L; Dean, Robert A
2016-12-15
Amyloid-β 1-42 peptide (Aβ 1-42 ) is associated with plaque formation in the brain of patients with Alzheimer's disease (AD). Pharmacodynamic studies of AD therapeutics that lower the concentrations of Aβ 1-42 in peripheral blood require highly sensitive assays for its measurement. A digital enzyme-linked immunosorbent assay (ELISA) using single molecule array (Simoa) technology has been developed that provides improved sensitivity compared with conventional ELISA methods using the same antibody reagents. A sensitive digital ELISA for measurement of Aβ 1-42 using antibodies 3D6 and 21F12 was developed. Assay performance was evaluated by repeated testing of pooled human plasma and buffer diluent quality control samples to determine relative accuracy, intra- and inter-assay precision, limit of detection (LOD), lower limit of quantification (LLOQ), dilutional linearity, and spike recovery. The optimized assay was used to quantify Aβ 1-42 in clinical samples from patients treated with the β-site amyloid precursor protein cleaving enzyme 1 inhibitor LY2886721. The prototype assay measured Aβ 1-42 with an LOD of 0.3 pg/ml and an LLOQ of 2.8 pg/ml in plasma, calibrated using an Aβ 1-42 peptide standard from Fujirebio. Assay precision was acceptable with intra- and inter-assay coefficients of variation both being ≤10%. Dilutional linearity was demonstrated in sample diluent and immunodepleted human plasma. Analyte spike recovery ranged from 51% to 93% with a mean of 80%. This assay was able to quantify Aβ 1-42 in all of the 84 clinical samples tested. A rapid reduction in levels of Aβ 1-42 was detected within 1 h after drug treatment, and a dose-dependent decrease of Aβ 1-42 levels was also observed over the time course of sample collection. This digital ELISA has potential utility in clinical applications for quantification of Aβ 1-42 in plasma where high sensitivity and precision are required.
Singh, Ruchi; Singh, Dhirendra Pratap; Savargaonkar, Deepali; Singh, Om P; Bhatt, Rajendra M; Valecha, Neena
2017-01-01
Loop-mediated isothermal amplification (LAMP) is an emerging nucleic acid based diag- nostic approach that is easily adaptable to the field settings with limited technical resources. This study was aimed to evaluate the LAMP assay for the detection and identification of Plasmodium falciparum and P. vivax infection in malaria suspected cases using genus and species-specific assay. The 18S rRNA-based LAMP assay was evaluated for diagnosis of genus Plasmodium, and species- specific diagnosis of P. falciparum and P. vivax, infection employing 317 malaria suspected cases, and the results were compared with those obtained by 18S nested PCR (n-PCR). All the samples were confirmed by microscopy for the presence of Plasmodium parasite. The n-PCR was positive in all Plasmodium-infected cases (n=257; P. falciparum=133; P. vivax=124) and negative in microscopy negative cases (n=58) except for two cases which were positive for P. vivax, giving a sen- sitivity of 100% (95% CI: 97.04-100%) and a specificity of 100% (95% CI: 88.45-99.5%). Genus-specific LAMP assay missed 11 (3.2%) microscopy and n-PCR confirmed vivax malaria cases. Considering PCR results as a refer- ence, LAMP was 100% sensitive and specific for P. falciparum, whereas it exhibited 95.16% sensitivity and 96.7% specificity for P. vivax. The n-PCR assay detected 10 mixed infection cases while species-specific LAMP detected five mixed infection cases of P. vivax and P. falciparum, which were not detected by microscopy. Genus-specific LAMP assay displayed low sensitivity. Falciparum specific LAMP assay displayed high sensitivity whereas vivax specific LAMP assay displayed low sensitivity. Failed detection of vivax cases otherwise confirmed by the n-PCR assay indicates exploitation of new targets and improved detection methods to attain 100% results for P. vivax detection.
Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis
An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting
2015-01-01
The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 “borderline” samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. PMID:25972403
Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.
An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan
2015-07-01
The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
A Protein Microarray ELISA for the Detection of Botulinum neurotoxin A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varnum, Susan M.
An enzyme-linked immunosorbent assay (ELISA) microarray was developed for the specific and sensitive detection of botulinum neurotoxin A (BoNT/A), using high-affinity recombinant monoclonal antibodies against the receptor binding domain of the heavy chain of BoNT/A. The ELISA microarray assay, because of its sensitivity, offers a screening test with detection limits comparable to the mouse bioassay, with results available in hours instead of days.
Liu, Xiaojuan; Xu, Ningning; Gai, Panpan; Li, Feng
2018-08-01
Since melamine is a strong hazard to human health, the development of new methods for highly sensitive detection of melamine is highly desirable. Herein, a novel fluorescent biosensing strategy was designed for sensitive and selective melamine assay based on the recognition ability of abasic (AP) site in triplex towards melamine and signal amplification by Mg 2+ -dependent DNAzyme. In this strategy, the melamine-induced formation of triplex DNA was employed to trigger the strand displacement reaction (SDR). The SDR process converted the specific target recognition into the release and activation of Mg 2+ -dependent DNAzyme, which could catalyze the cleavage of fluorophore/quencher labeled DNA substrate (FQ), resulting in a significantly increased fluorescent signal. Under the optimal conditions, the fluorescent signal has a linear relationship with the logarithm of the melamine concentration in a wide range of 0.005-50 μM. The detection limit was estimated to be 0.9 nM (0.1ppb), which is sufficiently sensitive for practical application. Furthermore, this strategy exhibits high selectivity against other potential interfering substances, and the practical application of this strategy for milk samples reveals that the proposed strategy works well for melamine assay in real samples. Therefore, this strategy presents a new method for the sensitive melamine assay and holds great promise for sensing applications in the environment and the food safety field. Copyright © 2018 Elsevier B.V. All rights reserved.
Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad
2017-01-01
To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939
Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad
2017-01-01
To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2 = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.
Patel, Pranav; Landt, Olfert; Kaiser, Marco; Faye, Oumar; Koppe, Tanja; Lass, Ulrich; Sall, Amadou A; Niedrig, Matthias
2013-02-14
The genus Flavivirus includes several pathogenic agents that cause severe illness in humans. Re-emergence of West Nile virus in Europe and continuous spread of certain flaviviruses such as dengue, yellow fever and Japanese encephalitis viruses represent a global danger to public health. Therefore, a rapid and accurate molecular method is required for diagnostics and epidemiological surveillance of flaviviruses. A Pan-Flavi quantitative RT-PCR assay using a Locked-Nucleic Acid probe targeting the flavivirus NS5 gene was developed and optimized to detect a wide range of flaviviruses simultaneously. The specificity and sensitivity of the Pan-Flavi assay were tested using RNA of different flaviviruses and non-flaviviruses. Furthermore, the assay was compared directly to flavivirus species-specific assays for the ability to detect flaviviruses sensitively. Two degenerate primers and one Locked-Nucleic Acids probe were designed to amplify most of the flaviviruses. To increase the specificity and fluorescence signal of the Pan-Flavi assay for detection of yellow fever virus and dengue virus 4, additional primers and probes were included. Viral RNA of thirty different flaviviruses was detected, verifying the broad range specificity. The testing of this assay was successful, using standard plasmid and RNA dilutions of yellow fever virus vaccine strain, dengue virus 1 and tick-borne encephalitis virus, with a sensitivity limit of 10-100 genome copies/reaction. Also comparatively good results were achieved for detecting different flaviviruses by the Pan-Flavi assay when compared to the flavivirus species-specific assays. The assay is rapid, broad-range flavivirus-specific and highly sensitive making it a valuable tool for rapid detection of flaviviruses in livestock samples, epidemiological studies or as useful complement to single flavivirus-specific assays for clinical diagnosis.
Gibbons-Burgener, S N; Kaneene, J B; Lloyd, J W; Leykam, J F; Erskine, R J
2001-11-01
To determine the likelihood of false-positive results when testing milk samples from individual cows by use of 3 commercially available assays (Penzyme MilkTest and the SNAP beta-lactam and Delvo-SP assays) labeled for use with commingled milk. Milk samples from 111 cows with mild clinical mastitis. Cows were randomly assigned to the control (no antimicrobials) or intramammary treatment group. Posttreatment milk samples were collected at the first milking after the labeled withholding period or an equivalent time for controls, randomly ordered, and tested twice by use of each assay and once by use of high-performance liquid chromatography. Sensitivity, specificity, and positive and negative predictive values were determined for each assay. Concordance of results for the same sample was assessed for each assay by calculating kappa. Sensitivities of the Delvo-SP and SNAP lactam assays were > 90%, whereas the sensitivity of the Penzyme Milk Test was 60%. Positive predictive values (range, 39.29 to 73.68%) were poor for all 3 assays. Concordance of test results was excellent for the SNAP beta-lactam and Delvo-SP assays (kappa = 0.846 and 0.813, respectively) but was less for the Penzyme MilkTest (kappa = 0.545). Because of the low positive predictive values, these 3 assays may not be useful for detecting violative antimicrobial residues in individual milk samples from cows treated for mild clinical mastitis. However, repeatability of each assay was considered good to excellent.
The noninvasive mouse ear swelling assay. II. Testing the contact sensitizing potency of fragrances.
Thorne, P S; Hawk, C; Kaliszewski, S D; Guiney, P D
1991-11-01
The noninvasive mouse ear swelling assay (MESA) for contact allergy testing was evaluated using fragrance components and complex fragrance mixtures. The test materials represented weak sensitizers and nonsensitizers. Two versions of the MESA were investigated. Both were noninvasive and utilized only topical abdominal dosing and ear challenge with single applications in BALB/cBy mice. The vit A MESA differed from the regular MESA only in that mice were maintained on a diet with 17-fold higher levels of vitamin A (vit A) acetate beginning 3 weeks prior to induction. Sensitization reactions were determined by measuring the mean increase in ear swelling over baseline at 24, 48 and 72 hr postexposure. Irritation dose-response curves facilitated choosing a high nonirritating challenge dose. Sensitization dose-response curves were developed for cinnamaldehyde (CINN) and a complex fragrance mixture, F-16. From these curves, the SD50 was determined. This value represents the dose which sensitized half the animals and serves to rank the potency of compounds for allergic contact dermatitis and to compare values among different assays. The SD50 for CINN was 21.6% while the SD50vit A for F-16 was 26.6%. The other fragrance, isoeugenol (ISOE), and fragrance mixtures, F-07 and F-22, were also found to be weak sensitizers in the MESA and vit A MESA. The results in the MESA for CINN and ISOE were in the range observed with guinea pig test protocols but showed that the MESA was more sensitive than human test protocols. Two of the fragrance mixtures tested in the MESA gave comparable results in the Buehler guinea pig assay. However, the third (F-22) was negative in the Buehler assay and the MESA, but positive in the vit A MESA. The results of this work with weak sensitizers and the companion study (Thorne et al., 1991) with potent sensitizers at low doses illustrate that the noninvasive MESA is as sensitive as many standard guinea pig assays. In addition, it is easier and much less expensive to perform. The vit A MESA has the sensitivity and predictive power needed to test compounds and mixtures for contact sensitizing potency.
Goay, Yuan Xin; Chin, Kai Ling; Tan, Clarissa Ling Ling; Yeoh, Chiann Ying; Ja'afar, Ja'afar Nuhu; Zaidah, Abdul Rahman; Chinni, Suresh Venkata; Phua, Kia Kien
2016-01-01
Salmonella Typhi ( S . Typhi) causes typhoid fever which is a disease characterised by high mortality and morbidity worldwide. In order to curtail the transmission of this highly infectious disease, identification of new markers that can detect the pathogen is needed for development of sensitive and specific diagnostic tests. In this study, genomic comparison of S . Typhi with other enteric pathogens was performed, and 6 S . Typhi genes, that is, STY0201, STY0307, STY0322, STY0326, STY2020, and STY2021, were found to be specific in silico . Six PCR assays each targeting a unique gene were developed to test the specificity of these genes in vitro . The diagnostic sensitivities and specificities of each assay were determined using 39 S . Typhi, 62 non-Typhi Salmonella , and 10 non- Salmonella clinical isolates. The results showed that 5 of these genes, that is, STY0307, STY0322, STY0326, STY2020, and STY2021, demonstrated 100% sensitivity (39/39) and 100% specificity (0/72). The detection limit of the 5 PCR assays was 32 pg for STY0322, 6.4 pg for STY0326, STY2020, and STY2021, and 1.28 pg for STY0307. In conclusion, 5 PCR assays using STY0307, STY0322, STY0326, STY2020, and STY2021 were developed and found to be highly specific at single-gene target resolution for diagnosis of typhoid fever.
Nikolova, Teodora; Marini, Federico; Kaina, Bernd
2017-10-01
Genotoxicity testing relies on the quantitative measurement of adverse effects, such as chromosome aberrations, micronuclei, and mutations, resulting from primary DNA damage. Ideally, assays will detect DNA damage and cellular responses with high sensitivity, reliability, and throughput. Several novel genotoxicity assays may fulfill these requirements, including the comet assay and the more recently developed γH2AX assay. Although they are thought to be specific for genotoxicants, a systematic comparison of the assays has not yet been undertaken. In the present study, we compare the γH2AX focus assay with the alkaline and neutral versions of the comet assay, as to their sensitivities and limitations for detection of genetic damage. We investigated the dose-response relationships of γH2AX foci and comet tail intensities at various times following treatment with four prototypical genotoxicants, methyl methanesulfonate (MMS), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), mitomycin C, and hydrogen peroxide (H 2 O 2 ) and we tested whether there is a correlation between the endpoints, i.e., alkali-labile sites and DNA strand breaks on the one hand and the cell's response to DNA double-strand breaks and blocked replication forks on the other. Induction of γH2AX foci gave a linear dose response and all agents tested were positive in the assay. The increase in comet tail intensity was also a function of dose; however, mitomycin C was almost completely ineffective in the comet assay, and the doses needed to achieve a significant effect were somewhat higher for some treatments in the comet assay than in the γH2AX foci assay, which was confirmed by threshold analysis. There was high correlation between tail intensity and γH2AX foci for MMS and H 2 O 2 , less for MNNG, and none for mitomycin C. From this we infer that the γH2AX foci assay is more reliable, sensitive, and robust than the comet assay for detecting genotoxicant-induced DNA damage. Copyright © 2017 Elsevier B.V. All rights reserved.
Smit, Erica; Erasmus, Mzwandile; Day, Jonathan; Makhethe, Lebohang; de Kock, Marwou; Hughes, E. Jane; van Rooyen, Michele; Stone, Lynnett; Hanekom, Willem; Brennan, Michael J.; Wallis, Robert S.; Hatherill, Mark; Scriba, Thomas J.
2017-01-01
The determinants of immunological protection against Mycobacterium tuberculosis (M.tb) infection in humans are not known. Mycobacterial growth inhibition assays have potential utility as in vitro surrogates of in vivo immunological control of M.tb. We evaluated a whole blood growth inhibition assay in a setting with high burden of TB and aimed to identify immune responses that correlate with control of mycobacterial growth. We hypothesized that individuals with underlying M.tb infection will exhibit greater M.tb growth inhibition than uninfected individuals and that children aged 4 to 12 years, an age during which TB incidence is curiously low, will also exhibit greater M.tb growth inhibition than adolescents or adults. Neither M.tb infection status, age of the study participants, nor M.tb strain was associated with differential control of mycobacterial growth. Abundance and function of innate or T cell responses were also not associated with mycobacterial growth. Our data suggest that this assay does not provide a useful measure of age-associated differential host control of M.tb infection in a high TB burden setting. We propose that universally high levels of mycobacterial sensitization (through environmental non-tuberculous mycobacteria and/or universal BCG vaccination) in persons from high TB burden settings may impart broad inhibition of mycobacterial growth, irrespective of M.tb infection status. This sensitization may mask the augmentative effects of mycobacterial sensitization on M.tb growth inhibition that is typical in low burden settings. PMID:28886145
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.
2012-08-03
Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the developmentmore » of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.« less
Song, Yunke; Zhang, Yi; Wang, Tza-Huei
2013-04-08
Gene point mutations present important biomarkers for genetic diseases. However, existing point mutation detection methods suffer from low sensitivity, specificity, and a tedious assay processes. In this report, an assay technology is proposed which combines the outstanding specificity of gap ligase chain reaction (Gap-LCR), the high sensitivity of single-molecule coincidence detection, and the superior optical properties of quantum dots (QDs) for multiplexed detection of point mutations in genomic DNA. Mutant-specific ligation products are generated by Gap-LCR and subsequently captured by QDs to form DNA-QD nanocomplexes that are detected by single-molecule spectroscopy (SMS) through multi-color fluorescence burst coincidence analysis, allowing for multiplexed mutation detection in a separation-free format. The proposed assay is capable of detecting zeptomoles of KRAS codon 12 mutation variants with near 100% specificity. Its high sensitivity allows direct detection of KRAS mutation in crude genomic DNA without PCR pre-amplification. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Ya; Li, Yanqing; Zhao, Junli; Zheng, Xiaojing; Mao, Qinwen; Xia, Haibin
2016-12-01
Enzyme-linked immunosorbent assay (ELISA) has been one of the main methods for detecting an antigen in an aqueous sample for more than four decades. Nowadays, one of the biggest concerns for ELISA is still how to improve the sensitivity of the assay, and the luciferase-luciferin reaction system has been noticed as a new detection method with high sensitivity. In this study, a luciferin-luciferase reaction system was used as the detection method for a sandwich ELISA system. It was shown that this new system led to an increase in the detection sensitivity of at least two times when compared with the traditional horseradish peroxidase (HRP) detection method. Lastly, the serum levels of the human extracellular matrix 1 protein of breast cancer patients were determined by the new system, which were overall similar to the HRP chemiluminescent system. Furthermore, this new luciferase reporter can be implemented into other ELISA systems for the purpose of increasing the assay sensitivity.
[Diagnostics of acute myocardial infarction in elderly patients].
Bahrmann, P; Heppner, H J; Bahrmann, A; Christ, M; Bertsch, T; Sieber, C C
2011-06-01
The early diagnosis of an acute myocardial infarction (MI) is improved by the introduction of novel high-sensitivity troponin assays. These assays can measure low level myocardial injury not detectable by standard troponin assays. Especially in older patients who appear to have a higher basal troponin level, the results must always be judged in the context of the medical history, physical examination, electrocardiogram (ECG) and any further findings. Even small increases in high-sensitivity troponin indicate increased risk for death or MI during follow-up. In the case of MI an invasive strategy results in better survival rates compared with conservative therapy but at the expense of an increased risk of bleeding in elderly patients. This article provides an overview on the diagnosis of MI in elderly patients.
Zehender, Hartmut; Mayr, Lorenz M
2007-10-01
In recent years, mass spectrometry has gained widespread use as an assay and screening technology in drug discovery because it enables sensitive, label-free detection of low-molecular weight modulators of biomolecules as well as sensitive and accurate detection of high-molecular weight modifications of biomolecules. Electrospray and matrix-assisted laser desorption ionization are the most widely used ionization techniques to identify chemical compounds interfering with enzymatic function, receptor-ligand binding or molecules modulating a protein-protein interaction of interest. Mass spectrometry based techniques are no longer restricted to screening in biochemical assay systems but have now become also applicable to imaging of biomolecules and chemical compounds in cell-based assay systems and even in highly complex tissue sections.
Viveiros, Miguel; Leandro, Clara; Rodrigues, Liliana; Almeida, Josefina; Bettencourt, Rosário; Couto, Isabel; Carrilho, Lurdes; Diogo, José; Fonseca, Ana; Lito, Luís; Lopes, João; Pacheco, Teresa; Pessanha, Mariana; Quirim, Judite; Sancho, Luísa; Salfinger, Max; Amaral, Leonard
2005-01-01
The INNO-LiPA Rif.TB assay for the identification of Mycobacterium tuberculosis complex strains and the detection of rifampin (RIF) resistance has been evaluated with 360 smear-positive respiratory specimens from an area of high incidence of multidrug-resistant tuberculosis (MDR-TB). The sensitivity when compared to conventional identification/culture methods was 82.2%, and the specificity was 66.7%; the sensitivity and specificity were 100.0% and 96.9%, respectively, for the detection of RIF resistance. This assay has the potential to provide rapid information that is essential for the effective management of MDR-TB. PMID:16145166
Li, Jian; Milne, Robert W.; Nation, Roger L.; Turnidge, John D.; Coulthard, Kingsley; Valentine, Jason
2002-01-01
A simple and sensitive high-performance liquid chromatographic method is described for the determination of colistimethate sodium in plasma and urine. The accuracy and reproducibility was within 10.1 and 11.2% with rat plasma and urine, respectively. Several commonly coadministered antibacterial agents do not interfere with the assay. PMID:12234867
Lin, Sansan; Fischl, Anthony S; Bi, Xiahui; Parce, Wally
2003-03-01
Phospholipid molecules such as ceramide and phosphoinositides play crucial roles in signal transduction pathways. Lipid-modifying enzymes including sphingomyelinase and phosphoinositide kinases regulate the generation and degradation of these lipid-signaling molecules and are important therapeutic targets in drug discovery. We now report a sensitive and convenient method to separate these lipids using microfluidic chip-based technology. The method takes advantage of the high-separation power of the microchips that separate lipids based on micellar electrokinetic capillary chromatography (MEKC) and the high sensitivity of fluorescence detection. We further exploited the method to develop a homogenous assay to monitor activities of lipid-modifying enzymes. The assay format consists of two steps: an on-plate enzymatic reaction using fluorescently labeled substrates followed by an on-chip MEKC separation of the reaction products from the substrates. The utility of the assay format for high-throughput screening (HTS) is demonstrated using phospholipase A(2) on the Caliper 250 HTS system: throughput of 80min per 384-well plate can be achieved with unattended running time of 5.4h. This enabling technology for assaying lipid-modifying enzymes is ideal for HTS because it avoids the use of radioactive substrates and complicated separation/washing steps and detects both substrate and product simultaneously.
Battery operated preconcentration-assisted lateral flow assay.
Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon
2017-07-11
Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.
Nzelu, Chukwunonso O; Cáceres, Abraham G; Guerrero-Quincho, Silvia; Tineo-Villafuerte, Edwin; Rodriquez-Delfin, Luis; Mimori, Tatsuyuki; Uezato, Hiroshi; Katakura, Ken; Gomez, Eduardo A; Guevara, Angel G; Hashiguchi, Yoshihisa; Kato, Hirotomo
2016-01-01
Leishmaniasis remains one of the world's most neglected diseases, and early detection of the infectious agent, especially in developing countries, will require a simple and rapid test. In this study, we established a quick, one-step, single-tube, highly sensitive loop-mediated isothermal amplification (LAMP) assay for rapid detection of Leishmania DNA from tissue materials spotted on an FTA card. An FTA-LAMP with pre-added malachite green was performed at 64°C for 60min using a heating block and/or water bath and DNA amplification was detected immediately after incubation. The LAMP assay had high detection sensitivity down to a level of 0.01 parasites per μl. The field- and clinic-applicability of the colorimetric FTA-LAMP assay was demonstrated with 122 clinical samples collected from patients suspected of having cutaneous leishmaniasis in Peru, from which 71 positives were detected. The LAMP assay in combination with an FTA card described here is rapid and sensitive, as well as simple to perform, and has great potential usefulness for diagnosis and surveillance of leishmaniasis in endemic areas. Copyright © 2015 Elsevier B.V. All rights reserved.
Dráberová, Eduarda; Stegurová, Lucie; Sulimenko, Vadym; Hájková, Zuzana; Dráber, Petr; Dráber, Pavel
2013-09-30
Microtubules formed by αβ-tubulin dimers represent cellular structures that are indispensable for the maintenance of cell morphology and for cell motility generation. Microtubules in intact cells are in highly regulated equilibrium with cellular pools of soluble tubulin dimers. Sensitive, reproducible and rapid assays are necessary to monitor tubulin changes in cytosolic pools after treatment with anti-mitotic drugs, during the cell cycle or activation and differentiation events. Here we describe new assays for α-tubulin quantification. The assays are based on sandwich ELISA, and the signal is amplified with biotinyl-tyramide or immuno-PCR. Matching monoclonal antibody pair recognizes phylogenetically highly conserved epitopes localized outside the C-terminal isotype-defining region. This makes it possible to detect α-tubulin isotypes in different cell types of various species. Biotinyl-tyramide amplification and immuno-PCR amplification enable detection of tubulin at concentrations 2.5ng/ml and 0.086ng/ml, respectively. Immuno-PCR detection shows enhanced sensitivity and wider dynamic range when compared to ELISA with biotinyl-tyramide detection. Our results on taxol-treated and activated bone marrow-derived mast cells demonstrate, that the assays allow sensitive quantification of tubulin in complex biological fluids. © 2013.
Deshpande, Kanchanmala; Mishra, Rupesh K.; Bhand, Sunil
2010-01-01
A highly sensitive and specific enzyme inhibition assay based on alcohol oxidase (AlOx) and horseradish peroxidase (HRP) for determination of mercury Hg(II) in water samples has been presented. This article describes the optimization and miniaturization of an enzymatic assay using a chemiluminescence reaction. The analytical performance and detection limit for determination of Hg(II) was optimized in 96 well plates and further extended to 384 well plates with a 10-fold reduction in assay volume. Inhibition of the enzyme activity by dissolved Hg(II) was found to be linear in the range 5–500 pg·mL−1 with 3% CV in inter-batch assay. Due to miniaturization of assay in 384 well plates, Hg(II) was measurable as low as 1 pg·mL−1 within 15 min. About 10-fold more specificity of the developed assay for Hg(II) analysis was confirmed by challenging with interfering divalent metal ions such as cadmium Cd(II) and lead Pb(II). Using the proposed assay we could successfully demonstrate that in a composite mixture of Hg(II), Cd(II) and Pb(II), inhibition by each metal ion is significantly enhanced in the presence of the others. Applicability of the proposed assay for the determination of the Hg(II) in spiked drinking and sea water resulted in recoveries ranging from 100–110.52%. PMID:22163555
Mohamad, Nurhidayatul Asma; Mustafa, Shuhaimi; Khairil Mokhtar, Nur Fadhilah; El Sheikha, Aly Farag
2018-03-05
The pharmaceutical industry has boosted gelatin consumption worldwide. This is supported by the availability of cost-effective gelatin production from porcine by-products. However, cross-contamination of gelatin materials, where porcine gelatin was unintentionally included in the other animal sources of gelatin, has caused significant concerns about halal authenticity. The real-time polymerase chain reaction (PCR) has enabled a highly specific and sensitive animal species detection method in various food products. Hence, such a technique was employed in the present study to detect and quantify porcine DNA in gelatin using a molecular beacon probe, with differences in performance between mitochondrial (cytochrome b gene) and chromosomal DNA-(MPRE42 repetitive element) based porcine-specific PCR assays being compared. A higher sensitivity was observed in chromosomal DNA (MPRE-PCR assay), where this assay allows the detection of gelatin DNA at amounts as as low as 1 pg, whereas mitochondrial DNA (CBH-PCR assay) can only detect at levels down to 10 pg of gelatin DNA. When an analysis with commercial gelatin and gelatin capsule samples was conducted, the same result was observed, with a significantly more sensitive detection being provided by the repetitive element of chromosomal DNA. The present study has established highly sensitive DNA-based porcine detection systems derived from chromosomal DNA that are feasible for highly processed products such as gelatin and gelatin capsules containing a minute amount of DNA. This sensitive detection method can also be implemented to assist the halal authentication process of various food products available on the market. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Improving colorimetric assays through protein enzyme-assisted gold nanoparticle amplification.
Xie, Xiaoji; Xu, Wei; Liu, Xiaogang
2012-09-18
The discovery of the DNA-mediated assembly of gold nanoparticles was a great moment in the history of science; this understanding and chemical control enabled the rational design of functional nanomaterials as novel probes in biodetection. In contrast with conventional probes such as organic dyes, gold nanoparticles exhibit high photostability and unique size-dependent optical properties. Because of their high extinction coefficients and strong distance dependent optical properties, these nanoparticles have emerged over the past decade as a promising platform for rapid, highly sensitive colorimetric assays that allow for the visual detection of low concentrations of metal ions, small molecules, and biomacromolecules. These discoveries have deepened our knowledge of biological phenomena and facilitated the development of many new diagnostic and therapeutic tools. Despite these many advances and continued research efforts, current nanoparticle-based colorimetric detection systems still suffer from several drawbacks, such as limited sensitivity and selectivity. This Account describes the recent development of colorimetric assays based on protein enzyme-assisted gold nanoparticle amplification. The benefits of such detection systems include significantly improved detection sensitivity and selectivity. First, we discuss the general design of enzyme-modified nanoparticle systems in colorimetric assays. We show that a quantitative understanding of the unique properties of different enzymes is paramount for effective biological assays. We then examine the assays for nucleic acid detection based on different types of enzymes, including endonucleases, ligases, and polymerases. For each of these assays, we identify the underlying principles that contribute to the enhanced detection capability of nanoparticle systems and illustrate them with selected examples. Furthermore, we demonstrate that the combination of gold nanoparticles and specific enzymes can probe enzyme dynamics and function with high specificity, offering substantial advantages in both sensitivity and specificity over conventional detection methods. The screening of nuclease, methyltransferase, protease, and kinase activities can be colorimetrically performed in a straightforward manner. Finally, we discuss examples of colorimetric assays for metal ions and small molecules that constitute important advances toward visual monitoring of enzyme catalytic functions and gene expression. Although these enzyme-assisted assay methods hold great promise for myriad applications in biomedicine and bioimaging, the application of the described techniques in vivo faces formidable challenges. In addition, researchers do not fully understand the interactions of gold nanoparticles with enzyme molecules. This understanding will require the development of new techniques to probe enzyme substrate dynamics at the particle interface with higher spatial resolution and chemical specificity.
Peskova, Marie; Heger, Zbynek; Janda, Petr; Adam, Vojtech; Pekarik, Vladimir
2017-02-01
Antimicrobial peptides are currently considered as promising antiviral compounds. Current assays to evaluate the effectivity of peptides against enveloped viruses based on liposomes or hemolysis are encumbered by the artificial nature of liposomes or distinctive membrane composition of used erythrocytes. We propose a novel assay system based on enzymatic Ebola virus-like particles containing sensitive luciferase reporter. The assay was validated with several cationic and anionic peptides and compared with lentivirus inactivation and hemolytic assays. The assay is sensitive and easy to perform in standard biosafety level laboratory with potential for high-throughput screens. The use of virus-like particles in the assay provides a system as closely related to the native viruses as possible eliminating some issues associated with other more artificial set ups. We have identified CAM-W (KWKLWKKIEKWGQGIGAVLKWLTTWL) as a peptide with the greatest antiviral activity against infectious lentiviral vectors and filoviral virus-like particles. Copyright © 2016 Elsevier Inc. All rights reserved.
Ohad, Shoshanit; Ben-Dor, Shifra; Prilusky, Jaime; Kravitz, Valeria; Dassa, Bareket; Chalifa-Caspi, Vered; Kashi, Yechezkel; Rorman, Efrat
2016-01-01
The emerging microbial source tracking (MST) methodologies aim to identify fecal contamination originating from domestic and wild animals, and from humans. Avian MST is especially challenging, primarily because the Aves class includes both domesticated and wild species with highly diverse habitats and dietary characteristics. The quest for specific fecal bacterial MST markers can be difficult with respect to attaining sufficient assay sensitivity and specificity. The present study utilizes high throughput sequencing (HTS) to screen bacterial 16S rRNA genes from fecal samples collected from both domestic and wild avian species. Operational taxonomic unit (OTU) analysis was then performed, from which sequences were retained for downstream quantitative polymerase chain reaction (qPCR) marker development. Identification of unique avian host DNA sequences, absent in non-avian hosts, was then carried out using a dedicated database of bacterial 16S rRNA gene taken from the Ribosomal Database Project. Six qPCR assays were developed targeting the 16S rRNA gene of Lactobacillus, Gallibacterium, Firmicutes, Fusobacteriaceae, and other bacteria. Two assays (Av4143 and Av163) identified most of the avian fecal samples and demonstrated sensitivity values of 91 and 70%, respectively. The Av43 assay only identified droppings from battery hens and poultry, whereas each of the other three assays (Av24, Av13, and Av216) identified waterfowl species with lower sensitivities values. The development of an MST assay-panel, which includes both domestic and wild avian species, expands the currently known MST analysis capabilities for decoding fecal contamination.
Haserodt, Sarah; Aytekin, Metin; Dweik, Raed A
2011-02-01
Hyaluronan (HA) is a glycosaminoglycan found in the extracellular matrix and ranges from several thousand to millions of daltons in size. HA has importance in various pathological conditions and is known to be elevated in several diseases. Three commonly used, commercially available HA enzyme-linked immunosorbent assay (ELISA)-like assays (from Corgenix, Echelon and R&D) were compared on the basis of accuracy, sample variability and ability to measure a range of HA sizes. The Corgenix HA ELISA-like assay displayed the lowest intra-assay variability [coefficient of variation (CV) = 11.7 ± 3.6%], followed by R&D (CV = 12.3 ± 4.6%) and Echelon (CV = 18.9 ± 9.2%). Interassay variability was also lowest for the Corgenix assay (CV = 6.0%), intermediate for the Echelon assay (9.5%) and highest for the R&D assay (CV = 34.1%). The high interassay variability seen for the R&D assay may have been due to the effect of dilution, since the dilution-independent interassay variability was 15.5%. The concentration of the standard HA was overestimated by the Echelon assay by 85% and underestimated by the R&D and Corgenix assays by 34 and 32%, respectively. The Echelon HA ELISA-like assay was the most effective at measuring all sizes of HA tested (2 MDa and 132, 66 and 6.4 kDa), whereas the Corgenix and R&D assays were unable to detect 6.4 kDa HA. These findings suggest that the Echelon HA ELISA-like assay is better suited for size-sensitive HA measurements but has a relatively high variability. The Corgenix and R&D HA ELISA-like assays have low variability and high accuracy but are not suitable for detecting low-molecular-weight HA.
Development of an in vitro skin sensitization test based on ROS production in THP-1 cells.
Saito, Kazutoshi; Miyazawa, Masaaki; Nukada, Yuko; Sakaguchi, Hitoshi; Nishiyama, Naohiro
2013-03-01
Recently, it has been reported that reactive oxygen species (ROS) produced by contact allergens can affect dendritic cell migration and contact hypersensitivity. The aim of the present study was to develop a new in vitro assay that could predict the skin sensitizing potential of chemicals by measuring ROS production in THP-1 (human monocytic leukemia cell line) cells. THP-1 cells were pre-loaded with a ROS sensitive fluorescent dye, 5-(and 6-)-chloromethyl-2', 7'-dichlorodihydrofluorescein diacetate, acetyl ester (CM-H2DCFDA), for 15min, then incubated with test chemicals for 30min. The fluorescence intensity was measured by flow cytometry. For the skin sensitizers, 25 out of 30 induced over a 2-fold ROS production at more than 90% of cell viability. In contrast, increases were only seen in 4 out of 20 non-sensitizers. The overall accuracy for the local lymph node assay (LLNA) was 82% for 50 chemicals tested. A correlation was found between the estimated concentration showing 2-fold ROS production in the ROS assay and the EC3 values (estimated concentration required to induce positive response) of the LLNA. These results indicated that the THP-1 cell-based ROS assay was a rapid and highly sensitive detection system able to predict skin sensitizing potentials and potency of chemicals. Copyright © 2012 Elsevier Ltd. All rights reserved.
Immunoblotting assays for keratan sulfate.
Yoon, Jung Hae; Brooks, Randolph; Halper, Jaroslava
2002-07-15
The detection of microquantities of glycosaminoglycans (GAGs) in biological samples has been hampered by the lack of sensitive methods. In this paper we describe the modification and development of three sensitive assays capable of detecting nanogram quantities of GAGs in biological samples. The first assay detects total GAGs. It is a modified Alcian blue dye precipitation assay in which the dye binds to the negatively charged GAGs in CsCl-fractionated extracts from chicken tendons. This assay compares favorably with the widely used uronic acid assay in terms of its sensitivity and ability to detect all classes of GAGs, including keratan sulfate (KS). Two other assays, dot-blotting and immunoblotting, detect KS in complex mixtures and can be easily adapted for the detection of other GAGs. Both take advantage of binding of carboxyl and sulfate groups of GAGs to trivalent neodymium. In dot-blotting, samples were directly blotted onto nitrocellulose membrane soaked in Nd(2)(SO(4))(3) buffer, and KS was detected with the monoclonal anti-KS 5-D-4 antibody and an avidin-biotin complex detection system. In immunoblotting, the samples were first separated in 28% polyacrylamide gels, transferred onto a Nd(2)(SO(4))(3)-soaked nitrocellulose membrane using a phosphate buffer system, and stained and developed using the same protocol as in dot-blotting. Whereas dot-blotting allows the use of very low quantities of samples because of its high sensitivity (lower detection limit was 5 ng), immunoblotting provides more specificity.
Wang, Kai; Shao, Hongze; Pei, Zhihua; Hu, Guixue
2016-01-01
The aim of this experiment was to develop a loop-mediated isothermal amplification (LAMP) assay and to research the recent epidemiology of contagious ecthyma in Jilin Province, China, using the assay. A LAMP assay targeting a highly conserved region of the F1L gene was developed to detect contagious ecthyma virus (CEV). Three hundred and sixty-five cases from 64 flocks in 9 different areas of Jilin Province, China, from 2011 to 2014 were tested using the LAMP assay. The results showed that the sensitivity of the LAMP assay was 100 copies of the standard plasmid, which is 100-fold higher than the sensitivity of PCR. No cross-reactivity was observed with capripoxvirus, fowlpox virus, foot-and-mouth disease virus serotype O, foot-and-mouth disease virus serotype Asia I and bluetongue virus. The average positive rate was 19.73% (72/365), and the positive rate was highest in lambs aged 1-6 months. Our results demonstrated that CEV infection was very widespread in the flocks of Jilin Province and that the LAMP assay allows for easy, rapid, accurate and sensitive detection of CEV infection.
Kusakawa, Shinji; Yasuda, Satoshi; Kuroda, Takuya; Kawamata, Shin; Sato, Yoji
2015-12-08
Contamination with tumorigenic cellular impurities is one of the most pressing concerns for human cell-processed therapeutic products (hCTPs). The soft agar colony formation (SACF) assay, which is a well-known in vitro assay for the detection of malignant transformed cells, is applicable for the quality assessment of hCTPs. Here we established an image-based screening system for the SACF assay using a high-content cell analyzer termed the digital SACF assay. Dual fluorescence staining of formed colonies and the dissolution of soft agar led to accurate detection of transformed cells with the imaging cytometer. Partitioning a cell sample into multiple wells of culture plates enabled digital readout of the presence of colonies and elevated the sensitivity for their detection. In practice, the digital SACF assay detected impurity levels as low as 0.00001% of the hCTPs, i.e. only one HeLa cell contained in 10,000,000 human mesenchymal stem cells, within 30 days. The digital SACF assay saves time, is more sensitive than in vivo tumorigenicity tests, and would be useful for the quality control of hCTPs in the manufacturing process.
Kusakawa, Shinji; Yasuda, Satoshi; Kuroda, Takuya; Kawamata, Shin; Sato, Yoji
2015-01-01
Contamination with tumorigenic cellular impurities is one of the most pressing concerns for human cell-processed therapeutic products (hCTPs). The soft agar colony formation (SACF) assay, which is a well-known in vitro assay for the detection of malignant transformed cells, is applicable for the quality assessment of hCTPs. Here we established an image-based screening system for the SACF assay using a high-content cell analyzer termed the digital SACF assay. Dual fluorescence staining of formed colonies and the dissolution of soft agar led to accurate detection of transformed cells with the imaging cytometer. Partitioning a cell sample into multiple wells of culture plates enabled digital readout of the presence of colonies and elevated the sensitivity for their detection. In practice, the digital SACF assay detected impurity levels as low as 0.00001% of the hCTPs, i.e. only one HeLa cell contained in 10,000,000 human mesenchymal stem cells, within 30 days. The digital SACF assay saves time, is more sensitive than in vivo tumorigenicity tests, and would be useful for the quality control of hCTPs in the manufacturing process. PMID:26644244
Guillo, Christelle; Ferrance, Jerome P; Landers, James P
2006-04-28
Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required).
Hu, Peilei; Bai, Liqiong; Liu, Fengping; Ou, Xichao; Zhang, Zhiying; Yi, Songlin; Chen, Zhongnan; Gong, Daofang; Liu, Binbin; Guo, Jingwei; Tan, Yunhong
2014-01-01
The Xpert MTB/RIF showed high sensitivity and specificity in previous studies carried out in different epidemiological and geographical settings and patient populations in high-burden tuberculosis (TB) countries. However, there were little data obtained by validation or demonstration study of the assay in China. In this study, the performance of Xpert MTB/RIF was investigated in two county-level laboratories in Hunan Province, China. Consecutive patients with suspected pulmonary tuberculosis (PTB) and suspicion for multidrug-resistant tuberculosis (MDR-TB) were enrolled. For each patient suspected to have PTB, three sputum specimens (one spot sputum, one night sputum, and one morning sputum) were collected and each sputum was tested with smear microscopy, Löwenstein-Jensen (LJ) culture, and Xpert MTB/RIF test. For comparison across subgroups and testing methods, 95% confidence intervals were calculated. All analyses were done with SPSS 16.0, and P < 0.05 was regarded as significant. For case detection, the sensitivity of Xpert MTB/RIF was 100% for smear- and culture-positive TB and 88.6% for smear-negative and culture-positive TB; the overall sensitivity was 94.5% for all culture-positive patients. The specificity was 99.8%. The sensitivity of Xpert MTB/RIF assay was 22.0% in clinical TB patients and the specificity reached 100.0% in the group of patients who are infected with nontuberculous mycobacteria. For the detection of rifampin resistance, the sensitivity of MTB/RIF RIF-resistance detection was 92.9%, and the specificity was 98.7%. Of the 26 Xpert MTB/RIF-positive and RIF-resistant patients confirmed by LJ proportion tests, 20 (76.9%) patients were infected by MDR-TB. The Xpert MTB/RIF assay is a highly sensitive and specific method for diagnosis of TB and RIF resistance, which will enable it to have the potential to be used in county-level laboratories and lead to the reduction of the infectious pool and improvements in TB control in China. Further evaluations in county-level laboratories for implementing the assay are still required.
Detection of fish antigens aerosolized during fish processing using newly developed immunoassays.
Lopata, Andreas L; Jeebhay, Mohamed F; Reese, Gerald; Fernandes, Joshua; Swoboda, Ines; Robins, Thomas G; Lehrer, Samuel B
2005-09-01
Aerosolization of fish proteins during seafood processing has been identified as a potential route for allergic sensitization and occupational asthma among workers involved in high-risk activities. The aim of this study was to develop immunological assays for the quantification of aerosolized fish antigens in a fish-processing factory. Polyclonal antibodies to the main fish species processed in the factory (anchovy and pilchard) were generated in rabbits and compared by ELISA inhibition assay and immunoblotting. These antisera were utilized to develop ELISA assays for the detection of fish antigens. The ELISA inhibition assays were evaluated by analyzing environmental air samples collected from three areas in a fish-processing factory: pilchard canning, fish meal production and lobster processing. By immunoblotting, the rabbit polyclonal antibodies demonstrated IgG antibody binding patterns comparable with IgE antibodies of fish-sensitized patients, particularly in regard to the major fish allergens parvalbumins. The sensitivity of the fish-specific ELISA assays developed was 0.5 microg/ml. The ELISA inhibition assays were able to differentiate between the two different fish species of interest but did not recognize a crustacean species. Notable differences in exposure levels to canned pilchard and anchovy antigens were demonstrated in the three different working areas of the factory, with assays having a detection limit as low as 105 ng/m(3). These ELISA-based assays are sensitive and specific to quantify differential exposure levels to fish antigens produced during fish processing, making it possible to investigate exposure-disease response relationships among workers in this industry. Copyright (c) 2005 S. Karger AG, Basel.
Pimkina, Edita; Zablockis, Rolandas; Nikolayevskyy, Vladyslav; Danila, Edvardas; Davidaviciene, Edita
2015-11-01
Drug-resistant tuberculosis (TB) is an important public health problem in Lithuania with MDR rates in new cases reaching 11% in 2012. Currently available diagnostic tools are not fully adequate for an accurate and rapid result for diagnosis of TB and MDR-TB. To evaluate the performance of Xpert(®) MTB/RIF assay for an early diagnosis of TB and detection of rifampicin (RIF) resistance in routine settings in Lithuania. A total of 833 individual respiratory samples obtained from patients previously treated for TB and MDR-TB contacts were tested using the Xpert MTB/RIF assay. Performance characteristics of the assay for TB and RIF resistance detection were calculated using culture and phenotypical DST results as a gold standard. The overall sensitivity and specificity of the Xpert MTB/RIF assay for TB detection were 93.7% and 91.7%, respectively with the sensitivity for smear-negative specimens reaching 82.5%. Resistance to RIF was detected in 81 (20.7%) primary specimens with no false negative results; there were 4/225 (1.8%) false-positives among strains sensitive to rifampicin. Overall sensitivity and specificity of the molecular assay for detection of RIF resistance calculated against phenotypic DST results were 100% and 98.2%, respectively. Our results demonstrate very good performance of the Xpert MTB/RIF assay for the detection of TB and RIF resistance on primary respiratory specimens. It provides strong evidence that implementation of the assay for routine laboratory diagnosis in high drug-resistance settings may improve and facilitate TB diagnosis. Copyright © 2015 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The serum virus neutralization (SVN) assay is a serological test to detect the presence and magnitude of functional systemic antibodies that prevent infectivity of a virus. The SVN assay is a highly sensitive and specific test that may be applied to influenza A viruses (IAV) in swine to measure the ...
Vrana, Julie A.; Theis, Jason D.; Dasari, Surendra; Mereuta, Oana M.; Dispenzieri, Angela; Zeldenrust, Steven R.; Gertz, Morie A.; Kurtin, Paul J.; Grogg, Karen L.; Dogan, Ahmet
2014-01-01
Examination of abdominal subcutaneous fat aspirates is a practical, sensitive and specific method for the diagnosis of systemic amyloidosis. Here we describe the development and implementation of a clinical assay using mass spectrometry-based proteomics to type amyloidosis in subcutaneous fat aspirates. First, we validated the assay comparing amyloid-positive (n=43) and -negative (n=26) subcutaneous fat aspirates. The assay classified amyloidosis with 88% sensitivity and 96% specificity. We then implemented the assay as a clinical test, and analyzed 366 amyloid-positive subcutaneous fat aspirates in a 4-year period as part of routine clinical care. The assay had a sensitivity of 90%, and diverse amyloid types, including immunoglobulin light chain (74%), transthyretin (13%), serum amyloid A (%1), gelsolin (1%), and lysozyme (1%), were identified. Using bioinformatics, we identified a universal amyloid proteome signature, which has high sensitivity and specificity for amyloidosis similar to that of Congo red staining. We curated proteome databases which included variant proteins associated with systemic amyloidosis, and identified clonotypic immunoglobulin variable gene usage in immunoglobulin light chain amyloidosis, and the variant peptides in hereditary transthyretin amyloidosis. In conclusion, mass spectrometry-based proteomic analysis of subcutaneous fat aspirates offers a powerful tool for the diagnosis and typing of systemic amyloidosis. The assay reveals the underlying pathogenesis by identifying variable gene usage in immunoglobulin light chains and the variant peptides in hereditary amyloidosis. PMID:24747948
Han, Jingjia; Qian, Ximei; Wu, Qingling; Jha, Rajneesh; Duan, Jinshuai; Yang, Zhou; Maher, Kevin O.; Nie, Shuming; Xu, Chunhui
2017-01-01
Human pluripotent stem cells (hPSCs) are a promising cell source for regenerative medicine, but their derivatives need to be rigorously evaluated for residual stem cells to prevent teratoma formation. Here, we report the development of novel surface-enhanced Raman scattering (SERS)-based assays that can detect trace numbers of undifferentiated hPSCs in mixed cell populations in a highly specific, ultra-sensitive, and time-efficient manner. By targeting stem cell surface markers SSEA-5 and TRA-1-60 individually or simultaneously, these SERS assays were able to identify as few as 1 stem cell in 106 cells, a sensitivity (0.0001%) which was ~2,000 to 15,000-fold higher than that of flow cytometry assays. Using the SERS assay, we demonstrate that the aggregation of hPSC-based cardiomyocyte differentiation cultures into 3D spheres significantly reduced SSEA-5+ and TRA-1-60+ cells compared with parallel 2D cultures. Thus, SERS may provide a powerful new technology for quality control of hPSC-derived products for preclinical and clinical applications. PMID:27509304
Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio
2013-01-01
A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700
Barabas, Sascha; Spindler, Theresa; Kiener, Richard; Tonar, Charlotte; Lugner, Tamara; Batzilla, Julia; Bendfeldt, Hanna; Rascle, Anne; Asbach, Benedikt; Wagner, Ralf; Deml, Ludwig
2017-03-07
In healthy individuals, Cytomegalovirus (CMV) infection is efficiently controlled by CMV-specific cell-mediated immunity (CMI). Functional impairment of CMI in immunocompromized individuals however can lead to uncontrolled CMV replication and severe clinical complications. Close monitoring of CMV-specific CMI is therefore clinically relevant and might allow a reliable prognosis of CMV disease as well as assist personalized therapeutic decisions. Objective of this work was the optimization and technical validation of an IFN-γ ELISpot assay for a standardized, sensitive and reliable quantification of CMV-reactive effector cells. T-activated® immunodominant CMV IE-1 and pp65 proteins were used as stimulants. All basic assay parameters and reagents were tested and optimized to establish a user-friendly protocol and maximize the signal-to-noise ratio of the ELISpot assay. Optimized and standardized ELISpot revealed low intra-assay, inter-assay and inter-operator variability (coefficient of variation CV below 22%) and CV inter-site was lower than 40%. Good assay linearity was obtained between 6 × 10 4 and 2 × 10 5 PBMC per well upon stimulation with T-activated® IE-1 (R 2 = 0.97) and pp65 (R 2 = 0.99) antigens. Remarkably, stimulation of peripheral blood mononuclear cells (PBMC) with T-activated® IE-1 and pp65 proteins resulted in the activation of a broad range of CMV-reactive effector cells, including CD3 + CD4 + (Th), CD3 + CD8 + (CTL), CD3 - CD56 + (NK) and CD3 + CD56 + (NKT-like) cells. Accordingly, the optimized IFN-γ ELISpot assay revealed very high sensitivity (97%) in a cohort of 45 healthy donors, of which 32 were CMV IgG-seropositive. The combined use of T-activated® IE-1 and pp65 proteins for the stimulation of PBMC with the optimized IFN-γ ELISpot assay represents a highly standardized, valuable tool to monitor the functionality of CMV-specific CMI with great sensitivity and reliability.
Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C
2015-09-01
The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.
Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.
2006-01-01
A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884
Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D
2006-02-01
Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.
Wilbur, Ami E; Ford, Susan E; Gauthier, Julie D; Gomez-Chiarri, Marta
2012-12-27
The continuing challenges to the management of both wild and cultured eastern oyster Crassostrea virginica populations resulting from protozoan parasites has stimulated interest in the development of molecular assays for their detection and quantification. For Haplosporidium nelsoni, the causative agent of multinucleated sphere unknown (MSX) disease, diagnostic evaluations depend extensively on traditional but laborious histological approaches and more recently on rapid and sensitive (but not quantitative) end-point polymerase chain reaction (PCR) assays. Here, we describe the development and application of a quantitative PCR (qPCR) assay for H. nelsoni using an Applied Biosystems TaqMan® assay designed with minor groove binder (MGB) probes. The assay was highly sensitive, detecting as few as 20 copies of cloned target DNA. Histologically evaluated parasite density was significantly correlated with the quantification cycle (Cq), regardless of whether quantification was categorical (r2 = 0.696, p < 0.0001) or quantitative (r2 = 0.797, p < 0.0001). Application in field studies conducted in North Carolina, USA (7 locations), revealed widespread occurrence of the parasite with moderate to high intensities noted in some locations. In Rhode Island, USA, application of the assay on oysters from 2 locations resulted in no positives.
Babu, Binoy; Washburn, Brian K; Miller, Steven H; Poduch, Kristina; Sarigul, Tulin; Knox, Gary W; Ochoa-Corona, Francisco M; Paret, Mathews L
2017-02-01
Rose rosette disease caused by Rose rosette virus (RRV; genus Emaravirus) is the most economically relevant disease of Knock Out ® series roses in the U.S. As there are no effective chemical control options for the disease, the most critical disease management strategies include the use of virus free clean plants for propagation and early detection and destruction of infected plants. The current diagnostic techniques for RRV including end-point reverse transcription-polymerase chain reaction (RT-PCR) and real-time PCR (RT-qPCR) are highly sensitive, but limited to diagnostic labs with the equipment and expertise; and is time consuming. To address this limitation, an isothermal reverse transcription-recombinase polymerase amplification (RT-RPA) assay based on multiple gene targets for specific detection of RRV was developed. The assay is highly specific and did not cross react with other viruses belonging to the inclusive and exclusive genus. Dilution assays using the in vitro transcripts showed that the primer sets designed (RPA-267, RPA-131, and RPA-321) are highly sensitive, consistently detecting RRV with a detection limit of 1fg/μL. Testing of the infected plants using the primer sets indicated that the virus could be detected from leaves, stems and petals of roses. The primer pair RPA-267 produced 100% positive detection of the virus from infected leaf tissues, while primer set RPA-131 produced 100% detection from stems and petals. The primer set RPA-321 produced 83%, 87.5% and 75% positive detection from leaves, petals and stem tissues, respectively. In addition, the assay has been efficiently used in the detection of RRV infecting Knock Out ® roses, collected from different states in the U.S. The assay can be completed in 20min as compared to the end-point RT-PCR assay (3-4h) and RT-qPCR (1.5h). The RT-RPA assay is reliable, rapid, highly sensitive, and can be easily used in diagnostic laboratories for detection of RRV with no need for any special equipment. Copyright © 2016 Elsevier B.V. All rights reserved.
Ko, Kiwoong; Yu, Shinae; Lee, Eun Hee; Park, Hyosoon; Woo, Hee-Yeon; Kwon, Min-Jung
2016-09-01
Various assays for detecting high-risk human papillomavirus (HR HPV) have been introduced recently, including the Abbott RealTime High-Risk HPV assay. We sought to compare the performance of Abbott PCR to Hybrid Capture 2 for the detection of HR HPV. A total of 941 cervical swab specimens were obtained. We submitted all specimens for HR HPV detection with HC2 and Abbott PCR, and then additionally analyzed discordant and concordant positive results using restriction fragment mass polymorphism (RFMP) genotyping analysis. HC2 detected one of 13 HR HPV types in 12.3% (116/941) of cases, while Abbott PCR detected one of 14 detectable HR HPV types in 12.9% (121/941) of cases. The overall agreement rate was 97.3% with a kappa coefficient of 0.879. Discordant results between these two assays were observed in 25 cases. HC2 showed a sensitivity of 90.0% and specificity of 95.9%, while Abbott PCR showed a sensitivity of 98.0% and specificity of 96.8% when using RFMP results as the gold standard. For HPV 16/18 detection, Abbott PCR showed 95.8%/88.9% sensitivity and 99.2%/99.8% specificity, respectively. The overall coinfection rate between HPV 16, 18 and non-16/18 was 9.9% (12/121) in Abbott PCR analysis. Considering its high agreement rate with HC2, higher sensitivity/specificity compared to HC2, and ability to differentiate HPV 16/18 from other HPV types, Abbott PCR could be a reliable laboratory testing method for the screening of HPV infections. © 2016 by the Association of Clinical Scientists, Inc.
Cullen, Louise; French, John K; Briffa, Tom G; Redfern, Julie; Hammett, Christopher J K; Brieger, David B; Parsonage, William A; Lefkovits, Jeffrey; Ellis, Chris; Astley, Carolyn; Howell, Tegwen Eleanor; Elliott, John M; Chew, Derek P B
2015-01-19
To examine differences in care and inhospital course of patients with possible acute coronary syndrome (ACS) in Australia and New Zealand based on whether a highly sensitive (hs) troponin assay was used at the hospital to which they presented. A snapshot study of consecutive patients presenting to hospitals in Australia and New Zealand from 14 to 27 May 2012 with possible ACS. Rates of major adverse cardiac events (inhospital death, new or recurrent myocardial infarction, stroke, cardiac arrest or worsening heart failure); association between assay type and outcome (via propensity score matching and a generalised estimating equation [GEE]; averages of the predicted outcomes among patients who were treated with and without the availability of an hs assay (via inverse probability-weighting [IPW] with regression-adjusted estimators). 4371 patients with possible ACS were admitted to 283 hospitals. Over half of the hospitals (156 [55%]) reported using the hs assay and most patients (2624 [60%]) had hs tests (P = 0.004). Use of the hs assay was independent of hospital coronary revascularisation capability. Patients tested with the hs assay had more non-invasive investigations (exercise tests, stress echocardiography, stress nuclear scans, and computed tomography coronary angiography) than those tested with the sensitive assay. However, there were no differences between the groups in rates of angiography or revascularisation. All adjusted analyses showed a consistently lower rate of inhospital events, including recurrent heart failure in patients for whom the hs assay was used (GEE odds ratio, 0.75; 95% CI, 0.60-0.94; P = 0.014); IPW analysis showed a 2.3% absolute reduction in these events with the use of the hs assay (P = 0.018). Use of hs troponin testing of patients hospitalised with possible ACS was associated with an increased rate of non-invasive cardiac investigations and fewer inhospital adverse events.
Hwang, Yusun; Lee, Miae
2012-05-01
We evaluated the performance of various commercial assays for the molecular detection of human papillomavirus (HPV); the recently developed AdvanSure HPV Screening real-time PCR assay (AdvanSure PCR) and the Abbott RealTime High Risk HPV PCR assay (Abbott PCR) were compared with the Hybrid Capture 2 HPV DNA Test (HC2). All 3 tests were performed on 177 samples, and any sample that showed a discrepancy in any of the 3 tests was genotyped using INNO-LiPA HPV genotyping and/or sequencing. On the basis of these results, we obtained a consensus HPV result, and the performance of each test was evaluated. We also evaluated high-risk HPV 16/18 detection by using the 2 real-time PCR assays. Among the 177 samples, 65 were negative and 75 were positive in all 3 assays; however, the results of the 3 assays with 37 samples were discrepant. Compared with the consensus HPV result, the sensitivities and specificities of HC2, AdvanSure PCR, and Abbott PCR were 97.6%, 91.7%, and 86.9% and 83.9%, 98.8%, and 100.0%, respectively. For HPV type 16/18 detection, the concordance rate between the AdvanSure PCR and Abbott PCR assays was 98.3%; however, 3 samples were discrepant (positive in AdvanSure PCR and negative in Abbott PCR) and were confirmed as HPV type 16 by INNO-LiPA genotyping and/or sequencing. For HPV detection, the AdvanSure HPV Screening real-time PCR assay and the Abbott PCR assay are less sensitive but more specific than the HC2 assay, but can simultaneously differentiate type 16/18 HPV from other types.
Bercovier, Herve; Fishman, Yolanta; Nahary, Ronen; Sinai, Sharon; Zlotkin, Amir; Eyngor, Marina; Gilad, Oren; Eldar, Avi; Hedrick, Ronald P
2005-01-01
Background Outbreaks with mass mortality among common carp Cyprinus carpio carpio and koi Cyprinus carpio koi have occurred worldwide since 1998. The herpes-like virus isolated from diseased fish is different from Herpesvirus cyprini and channel catfish virus and was accordingly designated koi herpesvirus (KHV). Diagnosis of KHV infection based on viral isolation and current PCR assays has a limited sensitivity and therefore new tools for the diagnosis of KHV infections are necessary. Results A robust and sensitive PCR assay based on a defined gene sequence of KHV was developed to improve the diagnosis of KHV infection. From a KHV genomic library, a hypothetical thymidine kinase gene (TK) was identified, subcloned and expressed as a recombinant protein. Preliminary characterization of the recombinant TK showed that it has a kinase activity using dTTP but not dCTP as a substrate. A PCR assay based on primers selected from the defined DNA sequence of the TK gene was developed and resulted in a 409 bp amplified fragment. The TK based PCR assay did not amplify the DNAs of other fish herpesviruses such as Herpesvirus cyprini (CHV) and the channel catfish virus (CCV). The TK based PCR assay was specific for the detection of KHV and was able to detect as little as 10 fentograms of KHV DNA corresponding to 30 virions. The TK based PCR was compared to previously described PCR assays and to viral culture in diseased fish and was shown to be the most sensitive method of diagnosis of KHV infection. Conclusion The TK based PCR assay developed in this work was shown to be specific for the detection of KHV. The TK based PCR assay was more sensitive for the detection of KHV than previously described PCR assays; it was as sensitive as virus isolation which is the golden standard method for KHV diagnosis and was able to detect as little as 10 fentograms of KHV DNA corresponding to 30 virions. PMID:15774009
[Multiplex real-time PCR method for rapid detection of Marburg virus and Ebola virus].
Yang, Yu; Bai, Lin; Hu, Kong-Xin; Yang, Zhi-Hong; Hu, Jian-Ping; Wang, Jing
2012-08-01
Marburg virus and Ebola virus are acute infections with high case fatality rates. A rapid, sensitive detection method was established to detect Marburg virus and Ebola virus by multiplex real-time fluorescence quantitative PCR. Designing primers and Taqman probes from highly conserved sequences of Marburg virus and Ebola virus through whole genome sequences alignment, Taqman probes labeled by FAM and Texas Red, the sensitivity of the multiplex real-time quantitative PCR assay was optimized by evaluating the different concentrations of primers and Probes. We have developed a real-time PCR method with the sensitivity of 30.5 copies/microl for Marburg virus positive plasmid and 28.6 copies/microl for Ebola virus positive plasmids, Japanese encephalitis virus, Yellow fever virus, Dengue virus were using to examine the specificity. The Multiplex real-time PCR assays provide a sensitive, reliable and efficient method to detect Marburg virus and Ebola virus simultaneously.
Recent Advances in Point-of-Care Diagnostics for Cardiac Markers
2014-01-01
National and international cardiology guidelines have recommended a 1-hour turnaround time for reporting results of cardiac troponin to emergency department personnel, measured from the time of blood collection to reporting. Use of point-of-care testing (POCT) can reduce turnaround times for cardiac markers, but current devices are not as precise or sensitive as central laboratory assays. The gap is growing as manufacturers of mainframe immunoassay instruments have or will release troponin assays that are even higher than those currently available. These assays have analytical sensitivity that enables detection of nearly 100% of all healthy subjects which is not possible for current POCT assays. Use of high sensitivity troponin results in a lower value for the 99th percentile of a healthy population. Clinically, this enables for the detection of more cases of myocardial injury. In order to compete analytically, next generation POCT assays will to make technologic advancements, such as the use of microfluidic to better control sample delivery, nanoparticles or nanotubes to increase the surface-to-volume ratios for analytes and antibodies, and novel detection schemes such as chemiluminescence and electrochemical detectors to enhance analytical sensitivity. Multi-marker analysis using POCT is also on the horizon for tests that complement cardiac troponin. PMID:27683464
Tips on the analysis of phosphatidic acid by the fluorometric coupled enzyme assay.
Hassaninasab, Azam; Han, Gil-Soo; Carman, George M
2017-06-01
The fluorometric coupled enzyme assay to measure phosphatidic acid (PA) involves the solubilization of extracted lipids in Triton X-100, deacylation, and the oxidation of PA-derived glycerol-3-phosphate to produce hydrogen peroxide for conversion of Amplex Red to resorufin. The enzyme assay is sensitive, but plagued by high background fluorescence from the peroxide-containing detergent and incomplete heat inactivation of lipoprotein lipase. These problems affecting the assay reproducibility were obviated by the use of highly pure Triton X-100 and by sufficient heat inactivation of the lipase enzyme. The enzyme assay could accurately measure the PA content from the subcellular fractions of yeast cells. Copyright © 2017 Elsevier Inc. All rights reserved.
Park, Seungman; Kang, Youjin; Kim, Dong Geun; Kim, Eui-Chong; Park, Sung Sup; Seong, Moon-Woo
2013-08-01
The detection of high-risk (HR) HPV in cervical cancer screening is important for early diagnosis of cervical cancer or pre-cancerous lesions. We evaluated the analytical and clinical performances of 3 HR HPV assays in Gynecology patients. A total of 991 specimens were included in this study: 787 specimens for use with a Hybrid Capture 2 (HC2) and 204 specimens for a HPV DNA microarray (DNA Chip). All specimens were tested using an Abbott RealTime High Risk HPV assay (Real-time HR), PGMY PCR, and sequence analysis. Clinical sensitivities for severe abnormal cytology (severe than high-grade squamous intraepithelial lesion) were 81.8% for Real-time HR, 77.3% for HC2, and 66.7% for DNA Chip, and clinical sensitivities for severe abnormal histology (cervical intraepithelial neoplasia grade 2+) were 91.7% for HC2, 87.5% for Real-time HR, and 73.3% for DNA Chip. As compared to results of the sequence analysis, HC2, Real-time HR, and DNA Chip showed concordance rates of 94.3% (115/122), 90.0% (117/130), and 61.5% (16/26), respectively. The HC2 assay and Real-time HR assay showed comparable results to each other in both clinical and analytical performances, while the DNA Chip assay showed poor clinical and analytical performances. The Real-time HR assay can be a good alternative option for HR HPV testing with advantages of allowing full automation and simultaneous genotyping of HR types 16 and 18. Copyright © 2013 Elsevier Inc. All rights reserved.
Mondal, Bhairab; Ramlal, Shylaja; Lavu, Padma S.; N, Bhavanashri; Kingston, Joseph
2018-01-01
A simple, sensitive and selective colorimetric biosensor for the detection of Staphylococcal enterotoxin B (SEB) was developed using SEB-binding aptamer (SEB2) as recognition element and unmodified gold nanoparticles (AuNPs) as colorimetric probes. The assay is based on color change from red to purple due to conformational change of aptamer in the presence of SEB, and the phenomenon of salt-induced AuNPs aggregation which could be monitored by naked eye or UV–vis spectrometer. Results showed that the AuNPs can effectively differentiate the SEB induced conformational change of the aptamer in the presence of a given high salt concentration. A linear response in the range of 50 μg/mL to 0.5 ng/mL of SEB concentration was obtained. The assay was highly specific to SEB as compared to other related toxins. The limit of detection (LOD) of SEB achieved within few minutes was 50 ng/mL visually and spectrometric method improved it to 0.5 ng/mL. Robustness of the assay was tested in artificially spiked milk samples and cross-checked using in house developed sandwich ELISA (IgY as capturing and SEB specific monoclonal as revealing antibody) and PCR. This colorimetric assay could be a suitable alternative over existing methods during biological emergencies due to its simplicity, sensitive and cost effectiveness. PMID:29487580
Cheng, Wenyu; He, Xiaobing; Jia, Huaijie; Chen, Guohua; Wang, Cong; Zhang, Jun; Jing, Zhizhong
2018-04-01
Ectromelia virus (ECTV) is the causative agent of mousepox, which has devastating effects in laboratory-mouse colonies and causes economic loss in biomedical research. More importantly, ECTV has been extensively used as an excellent model for studies of the pathogenesis and immunobiology of human smallpox. A rapid and sensitive SYBR Green I-based real-time PCR assay was developed and used for the detection and quantitation of orthopoxvirus by using ECTV in this study. Primers targeted to the highly conserved region of major core protein P4b gene of orthopoxvirus were designed and the standard plasmid was constructed. This assay was able to detect a minimum of 10 copies of standard DNA and 5 TCID 50 units of ECTV. In addition, no cross-reactions were observed with two DNA viruses, such as herpes simplex virus and swine pseudorabies virus, and one RNA virus, vesicular stomatitis virus. Furthermore, intra- and inter-assay variability data showed that this method had a highly reproducibility and reliability. Moreover, the current assay was faster and had a higher sensitivity for detection of ECTV genomic DNA in cell cultured and clinical test samples. Therefore, the high sensitivity and reproducibility of this SYBR Green real-time PCR approach is a more effective method than the conventional PCR for ECTV diagnosis and quantitation. Copyright © 2017. Published by Elsevier Ltd.
Development and validation of sensitive real-time RT-PCR assay for broad detection of rabies virus.
Faye, Martin; Dacheux, Laurent; Weidmann, Manfred; Diop, Sylvie Audrey; Loucoubar, Cheikh; Bourhy, Hervé; Sall, Amadou Alpha; Faye, Ousmane
2017-05-01
Rabies virus (RABV) remains one of the most important global zoonotic pathogens. RABV causes rabies, an acute encephalomyelitis associated with a high rate of mortality in humans and animals and affecting different parts of the world, particularly in Asia and Africa. Confirmation of rabies diagnosis relies on laboratory diagnosis, in which molecular techniques such as detection of viral RNA by reverse transcription polymerase chain reaction (RT-PCR) are increasingly being used. In this study, two real-time quantitative RT-PCR assays were developed for large-spectrum detection of RABV, with a focus on African isolates. The primer and probe sets were targeted highly conserved regions of the nucleoprotein (N) and polymerase (L) genes. The results indicated the absence of non-specific amplification and cross-reaction with a range of other viruses belonging to the same taxonomic family, i.e. Rhabdoviridae, as well as negative brain tissues from various host species. Analytical sensitivity ranged between 100 to 10 standard RNA copies detected per reaction for N-gene and L-gene assays, respectively. Effective detection and high sensitivity of these assays on African isolates showed that they can be successfully applied in general research and used in diagnostic process and epizootic surveillance in Africa using a double-check strategy. Copyright © 2017 Elsevier B.V. All rights reserved.
Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans
2012-09-01
assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX
Nanoamplifiers synthesized from gadolinium and gold nanocomposites for magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Tian, Xiumei; Shao, Yuanzhi; He, Haoqiang; Liu, Huan; Shen, Yingying; Huang, Wenlin; Li, Li
2013-03-01
We have synthesized an efficient and highly sensitive nanoamplifier composed of gadolinium-doped silica nanoparticles and gold nanoparticles (AuNPs). Magnetic resonance imaging (MRI) in vitro and in vivo assays revealed enhancement of signal sensitivity, which may be explained by electron transfer between water and gadolinium-doped nanoparticles, apparent in the presence of gold. In vitro and in vivo evaluation demonstrated nanoamplifier incurred minimal cytotoxicity and immunotoxicity, increased stability, and gradual excretion patterns. Tumor targeted properties were preliminarily determined when the nanoamplifier was injected into mouse models of colon cancer liver metastasis. Furthermore, although AuNPs departed from the nanoamplifiers in specific mice tissues, optical and magnetic resonance imaging was efficient, especially in metastatic tumors. These assays validate our nanoamplifier as an effective MRI signal enhancer with sensitive cancer diagnosis potential.We have synthesized an efficient and highly sensitive nanoamplifier composed of gadolinium-doped silica nanoparticles and gold nanoparticles (AuNPs). Magnetic resonance imaging (MRI) in vitro and in vivo assays revealed enhancement of signal sensitivity, which may be explained by electron transfer between water and gadolinium-doped nanoparticles, apparent in the presence of gold. In vitro and in vivo evaluation demonstrated nanoamplifier incurred minimal cytotoxicity and immunotoxicity, increased stability, and gradual excretion patterns. Tumor targeted properties were preliminarily determined when the nanoamplifier was injected into mouse models of colon cancer liver metastasis. Furthermore, although AuNPs departed from the nanoamplifiers in specific mice tissues, optical and magnetic resonance imaging was efficient, especially in metastatic tumors. These assays validate our nanoamplifier as an effective MRI signal enhancer with sensitive cancer diagnosis potential. Electronic supplementary information (ESI) available: Protocols for the characterization, immunotoxicity and pharmacokinetics analyses. Additional supporting figures. See DOI: 10.1039/c3nr00170a
Duval, Brea D; Elrod, Mindy G; Gee, Jay E; Chantratita, Narisara; Tandhavanant, Sarunporn; Limmathurotsakul, Direk; Hoffmaster, Alex R
2014-06-01
Cases of melioidosis and glanders are rare in the United States, but the etiologic agents of each disease (Burkholderia pseudomallei and Burkholderia mallei, respectively) are classified as Tier 1 select agents because of concerns about their potential use as bioterrorism agents. A rapid, highly sensitive, and portable assay for clinical laboratories and field use is required. Our laboratory has further evaluated a latex agglutination assay for its ability to identify B. pseudomallei and B. mallei isolates. This assay uses a monoclonal antibody that specifically recognizes the capsular polysaccharide produced by B. pseudomallei and B. mallei, but is absent in closely related Burkholderia species. A total of 110 B. pseudomallei and B. mallei were tested, and 36 closely related Burkholderia species. The latex agglutination assay was positive for 109 of 110 (99.1% sensitivity) B. pseudomallei and B. mallei isolates tested. © The American Society of Tropical Medicine and Hygiene.
Zhou, Zhenpeng; Li, Tian; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Chengzhi; Li, Na
2014-11-11
Silver-enhanced fluorescence was coupled with a bio-barcode assay to facilitate a dual amplification assay to demonstrate a non-enzymatic approach for simple and sensitive detection of DNA. In the assay design, magnetic nanoparticles seeded with silver nanoparticles were modified with the capture DNA, and silver nanoparticles were modified with the binding of ssDNA and the fluorescently labeled barcode dsDNA. Upon introduction of the target DNA, a sandwich structure was formed because of the hybridization reaction. By simple magnetic separation, silver-enhanced fluorescence of barcode DNAs could be readily measured without the need of a further step to liberate barcode DNAs from silver nanoparticles, endowing the method with simplicity and high sensitivity with a detection limit of 1 pM.
Evaluation of qPCR-Based Assays for Leprosy Diagnosis Directly in Clinical Specimens
Sarno, Euzenir Nunes; Moraes, Milton Ozório
2011-01-01
The increased reliability and efficiency of the quantitative polymerase chain reaction (qPCR) makes it a promising tool for performing large-scale screening for infectious disease among high-risk individuals. To date, no study has evaluated the specificity and sensitivity of different qPCR assays for leprosy diagnosis using a range of clinical samples that could bias molecular results such as difficult-to-diagnose cases. In this study, qPCR assays amplifying different M. leprae gene targets, sodA, 16S rRNA, RLEP and Ag 85B were compared for leprosy differential diagnosis. qPCR assays were performed on frozen skin biopsy samples from a total of 62 patients: 21 untreated multibacillary (MB), 26 untreated paucibacillary (PB) leprosy patients, as well as 10 patients suffering from other dermatological diseases and 5 healthy donors. To develop standardized protocols and to overcome the bias resulted from using chromosome count cutoffs arbitrarily defined for different assays, decision tree classifiers were used to estimate optimum cutoffs and to evaluate the assays. As a result, we found a decreasing sensitivity for Ag 85B (66.1%), 16S rRNA (62.9%), and sodA (59.7%) optimized assay classifiers, but with similar maximum specificity for leprosy diagnosis. Conversely, the RLEP assay showed to be the most sensitive (87.1%). Moreover, RLEP assay was positive for 3 samples of patients originally not diagnosed as having leprosy, but these patients developed leprosy 5–10 years after the collection of the biopsy. In addition, 4 other samples of patients clinically classified as non-leprosy presented detectable chromosome counts in their samples by the RLEP assay suggesting that those patients either had leprosy that was misdiagnosed or a subclinical state of leprosy. Overall, these results are encouraging and suggest that RLEP assay could be useful as a sensitive diagnostic test to detect M. leprae infection before major clinical manifestations. PMID:22022631
Wang, Zhanhui; Zhang, Huiyan; Ni, Hengjia; Zhang, Suxia; Shen, Jianzhong
2014-04-11
In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L(-1) to as low as 0.07 μg L(-1). The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step. Copyright © 2014 Elsevier B.V. All rights reserved.
Espín, J C; Tudela, J; García-Cánovas, F
1998-05-15
A continuous spectrophotometric method for determining the monophenolase activity of polyphenol oxidase from several plant sources is described. This assay method is based on the coupling reaction between 3-methyl-2-benzothiazolinone hydrazone and the quinone product of the oxidation of 4-hydroxyanisole in the presence of polyphenol oxidase. 4-Hydroxyanisole proved to be the best monophenol assayed to measure the monophenolase activity of polyphenol oxidase from apple, artichoke, avocado, medlar, pear, and strawberry. Kinetic constants of 4-hydroxyanisole were compared to those of p-hydroxyphenyl propionic acid, a very sensitive monophenol previously reported to assay the monophenolase activity of polyphenol oxidase from apple, pear, and mushroom. The high values of the maximum steady state rate obtained for 4-hydroxyanisole suggest the existence of high catalytic constant toward this monophenol. These kinetic values were supported by nuclear magnetic resonance assays which predicted the highest reactivity of 4-hydroxyanisole. Therefore nuclear magnetic resonance assays proved to be a valuable and useful tool to predict the best monophenolic substrate for plant polyphenol oxidases. The 3-methyl-2-benzothiazlolinone-adduct for 4-hydroxyanisole was stable, with high molar absorptivity at the optimum pHs of the polyphenol oxidases assayed. All this together makes the use of 4-hydroxyanisol as monophenolic substrate and 3-methyl-2-benzothiazolinone as coupling reagent the most sensitive and precise assay method up to date reported in the literature to determine the monophenolas activity of polyphenol oxidase from fruits and vegetables.
Beqa, Lule; Singh, Anant Kumar; Khan, Sadia Afrin; Senapati, Dulal; Arumugam, Sri Ranjini; Ray, Paresh Chandra
2011-03-01
Pb (II) is a common water pollutant with high toxicity. According to the CDC, about 310,000 U.S. children of ages 1-5 have high levels of lead in their blood that it is due to the exposure to lead from plastic toys and other products. As a result, the development of ultrasensitive assays for the real-time detection of Pb(II) from plastic toys and paints is very important for water controlling, clinical toxicology and industrial processes. Driven by the need to detect trace amounts of Pb(II) from water samples, we report a label-free, highly selective and ultra sensitive glutathione modified gold nanoparticle based dynamic light scattering (DLS) probe for Pb(II) recognition in 100 ppt level from aqueous solution with excellent discrimination against other heavy metals. The sensitivity of our assay to detect Pb(II) level in water is almost 2 orders of magnitude higher than the EPA standard limit. We have also demonstrated that our DLS assay is capable of measuring the amount of Pb(II) in paint, plastic toys, and water from MS river. A possible mechanism and operating principles of our DLS assay have been discussed. Ultimately, this nanotechnology driven assay could have enormous potential applications in rapid, on-site monitoring of Pb(II) from day-to-day sample.
Hemanth Kumar, A K; Polisetty, Arun Kumar; Sudha, V; Vijayakumar, A; Ramachandran, Geetha
2018-04-01
Cycloserine (CYC) is a second line antitubercular drug that is used for the treatment of multidrug resistant tuberculosis (MDR-TB) along with other antitubercular agents and is often used in developing countries. Monitoring CYC levels in plasma could be useful in the clinical management of patients with MDR-TB. A high performance liquid chromatography method for the determination of CYC in human plasma was developed. The method involved extraction of the sample using solid phase extraction cartridges and analysis of the extracted sample using a reverse phase T3 column (150mm) and detection at 240nm with Photo Diode Array (PDA) detector. The chromatogram was run for 15min at a flow rate of 0.4ml/min at 30°C. The assay was specific for CYC and linear from 5.0 to 50.0μg/ml. The relative standard deviations of within- and between-day assays were less than 10%. Recovery of CYC ranged from 102% to 109%. The interference of other second line anti-TB drugs in the assay of CYC was ruled out. The assay spans the concentration range of clinical interest. The specificity and sensitivity of this assay makes it highly suitable for pharmacokinetic studies. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
The comet assay: assessment of in vitro and in vivo DNA damage.
Bajpayee, Mahima; Kumar, Ashutosh; Dhawan, Alok
2013-01-01
Rapid industrialization and pursuance of a better life have led to an increase in the amount of chemicals in the environment, which are deleterious to human health. Pesticides, automobile exhausts, and new chemical entities all add to air pollution and have an adverse effect on all living organisms including humans. Sensitive test systems are thus required for accurate hazard identification and risk assessment. The Comet assay has been used widely as a simple, rapid, and sensitive tool for assessment of DNA damage in single cells from both in vitro and in vivo sources as well as in humans. Already, the in vivo comet assay has gained importance as the preferred test for assessing DNA damage in animals for some international regulatory guidelines. The advantages of the in vivo comet assay are its ability to detect DNA damage in any tissue, despite having non-proliferating cells, and its sensitivity to detect genotoxicity. The recommendations from the international workshops held for the comet assay have resulted in establishment of guidelines. The in vitro comet assay conducted in cultured cells and cell lines can be used for screening large number of compounds and at very low concentrations. The in vitro assay has also been automated to provide a high-throughput screening method for new chemical entities, as well as environmental samples. This chapter details the in vitro comet assay using the 96-well plate and in vivo comet assay in multiple organs of the mouse.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avonto, Cristina; Chittiboyina, Amar G.; Rua, Diego
2015-12-01
Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles aftermore » incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow and critical parameters is presented. • The method could provide a useful tool to complement existing chemical assays.« less
Lim, T K; Gough, A; Chin, N K; Kumarasinghe, G
2000-09-01
The AMPLICOR assay (Roche; Branchburg, NJ), a rapid direct amplification test for Mycobacterium tuberculosis, has only been licensed for use in smear-positive respiratory specimens. However, many patients with pulmonary tuberculosis (PTB) have smear-negative disease. The clinical utility of this test in patients with smear-negative PTB is unknown. To evaluate the effect of pretest probability of PTB estimated by chest physicians on the accuracy of the AMPLICOR assay in patients with smear-negative PTB. A prospective study of consecutive patients suspected of having smear-negative PTB. Two chest physicians estimated the pretest probability of active disease (high, intermediate, and low categories). Respiratory specimens were examined with radiometric broth medium cultures and with the AMPLICOR assay for M tuberculosis. The decision on a final diagnosis of PTB was blinded to the AMPLICOR results. Active PTB was diagnosed in 25 of 441 patients (5.7%). The AMPLICOR assay had an overall sensitivity of 44% and a specificity of 99%. Results of the assay were negative in seven patients with culture-negative PTB. The proportions of patients in the high, intermediate, and low pretest groups were 4.5%, 19.7%, and 75.7%, respectively. The incidence of PTB for each group was 95%, 3.4%, and 0.9%, respectively. The sensitivities of the AMPLICOR assay in the three groups of patients were 47%, 33%, and 33%, respectively, while the specificities were 100%, 98%, and 99%, respectively. In patients suspected of having smear-negative PTB, the following conclusions were drawn: (1) the incidence of active PTB was low; (2) pretest estimates accurately discriminated between patients with high and low risk of PTB; (3) the risk of PTB was overestimated in the intermediate group; and (4) the utility of the AMPLICOR assay in the intermediate-risk group may be limited by the overestimation of disease prevalence and low test sensitivity. Further studies are needed on the role of the AMPLICOR assay in better selected patients with an intermediate risk of having smear-negative PTB.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-02-20
We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.
Parallel human genome analysis: microarray-based expression monitoring of 1000 genes.
Schena, M; Shalon, D; Heller, R; Chai, A; Brown, P O; Davis, R W
1996-01-01
Microarrays containing 1046 human cDNAs of unknown sequence were printed on glass with high-speed robotics. These 1.0-cm2 DNA "chips" were used to quantitatively monitor differential expression of the cognate human genes using a highly sensitive two-color hybridization assay. Array elements that displayed differential expression patterns under given experimental conditions were characterized by sequencing. The identification of known and novel heat shock and phorbol ester-regulated genes in human T cells demonstrates the sensitivity of the assay. Parallel gene analysis with microarrays provides a rapid and efficient method for large-scale human gene discovery. Images Fig. 1 Fig. 2 Fig. 3 PMID:8855227
Luminogenic cytochrome P450 assays.
Cali, James J; Ma, Dongping; Sobol, Mary; Simpson, Daniel J; Frackman, Susan; Good, Troy D; Daily, William J; Liu, David
2006-08-01
Luminogenic cytochrome P450 (CYP) assays couple CYP enzyme activity to firefly luciferase luminescence in a technology called P450-Glo(TM) (Promega). Luminogenic substrates are used in assays of human CYP1A1, -1A2, -1B1, -2C8, -2C9, -2C19, -2D6, -2J2, -3A4, -3A7, -4A11, -4F3B, -4F12 and -19. The assays detect dose-dependent CYP inhibition by test compounds against recombinant CYP enzymes or liver microsomes. Induction or inhibition of CYP activities in cultured hepatocytes is measured in a nonlytic approach that leaves cells intact for additional analysis. Luminogenic CYP assays offer advantages of speed and safety over HPLC and radiochemical-based methods. Compared with fluorogenic methods the approach offers advantages of improved sensitivity and decreased interference between optical properties of test compound and CYP substrate. These homogenous assays are sensitive and robust tools for high-throughput CYP screening in early drug discovery.
Santiago, Gilberto A; Vázquez, Jesús; Courtney, Sean; Matías, Katia Y; Andersen, Lauren E; Colón, Candimar; Butler, Angela E; Roulo, Rebecca; Bowzard, John; Villanueva, Julie M; Muñoz-Jordan, Jorge L
2018-04-11
The emergence and spread of Zika virus (ZIKV) presented a challenge to the diagnosis of ZIKV infections in areas with transmission of dengue (DENV) and chikungunya (CHIKV) viruses. To facilitate detection of ZIKV infections, and differentiate these infections from DENV and CHIKV, we developed the Trioplex real-time RT-PCR assay (Trioplex assay). Here, we describe the optimization of multiplex and singleplex formats of the assay for a variety of chemistries and instruments to facilitate global standardization and implementation. We evaluated the analytical performance of all Trioplex modalities for detection of these three pathogens in serum and whole blood, and for ZIKV in urine. The limit of detection for the three viruses and in different RNA-extraction modalities is near 10 3 genome copy equivalents per milliliter (GCE/mL). Simultaneous testing of more than one specimen type from each patient provides a 6.4% additional diagnostic sensitivity. Overall, the high sensitivity of the Trioplex assay demonstrates the utility of this assay ascertaining Zika cases.
Validation of a next-generation sequencing assay for clinical molecular oncology.
Cottrell, Catherine E; Al-Kateb, Hussam; Bredemeyer, Andrew J; Duncavage, Eric J; Spencer, David H; Abel, Haley J; Lockwood, Christina M; Hagemann, Ian S; O'Guin, Stephanie M; Burcea, Lauren C; Sawyer, Christopher S; Oschwald, Dayna M; Stratman, Jennifer L; Sher, Dorie A; Johnson, Mark R; Brown, Justin T; Cliften, Paul F; George, Bijoy; McIntosh, Leslie D; Shrivastava, Savita; Nguyen, Tudung T; Payton, Jacqueline E; Watson, Mark A; Crosby, Seth D; Head, Richard D; Mitra, Robi D; Nagarajan, Rakesh; Kulkarni, Shashikant; Seibert, Karen; Virgin, Herbert W; Milbrandt, Jeffrey; Pfeifer, John D
2014-01-01
Currently, oncology testing includes molecular studies and cytogenetic analysis to detect genetic aberrations of clinical significance. Next-generation sequencing (NGS) allows rapid analysis of multiple genes for clinically actionable somatic variants. The WUCaMP assay uses targeted capture for NGS analysis of 25 cancer-associated genes to detect mutations at actionable loci. We present clinical validation of the assay and a detailed framework for design and validation of similar clinical assays. Deep sequencing of 78 tumor specimens (≥ 1000× average unique coverage across the capture region) achieved high sensitivity for detecting somatic variants at low allele fraction (AF). Validation revealed sensitivities and specificities of 100% for detection of single-nucleotide variants (SNVs) within coding regions, compared with SNP array sequence data (95% CI = 83.4-100.0 for sensitivity and 94.2-100.0 for specificity) or whole-genome sequencing (95% CI = 89.1-100.0 for sensitivity and 99.9-100.0 for specificity) of HapMap samples. Sensitivity for detecting variants at an observed 10% AF was 100% (95% CI = 93.2-100.0) in HapMap mixes. Analysis of 15 masked specimens harboring clinically reported variants yielded concordant calls for 13/13 variants at AF of ≥ 15%. The WUCaMP assay is a robust and sensitive method to detect somatic variants of clinical significance in molecular oncology laboratories, with reduced time and cost of genetic analysis allowing for strategic patient management. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Lermo, Anabel; Liébana, Susana; Campoy, Susana; Fabiano, Silvia; García, M Inés; Soutullo, Adriana; Zumárraga, Martín J; Alegret, Salvador; Pividori, M Isabel
2010-06-01
A highly sensitive assay for rapidly screening-out Mycobacterium bovis in contaminated samples was developed based on electrochemical genosensing. The assay consists of specific amplification and double-tagging of the IS6110 fragment, highly related to M. bovis, followed by electrochemical detection of the amplified product. PCR amplification was carried out using a labeled set of primers and resulted in a amplicon tagged at each terminus with both biotin and digoxigenin. Two different electrochemical platforms for the detection of the double-tagged amplicon were evaluated: (i) an avidin biocomposite (Av-GEB) and (ii) a magneto sensor (m-GEC) combined with streptavidin magnetic beads. In both cases, the double- tagged amplicon was immobilized through its biotinylated end and electrochemically detected, using an antiDig-HRP conjugate, through its digoxigenin end. The assay was determined to be highly sensitive, based on the detection of 620 and 10 fmol of PCR amplicon using the Av-GEB and m-GEC strategies, respectively. Moreover, the m-GEC assay showed promising features for the detection of M. bovis on dairy farms by screening for the presence of the bacterium's DNA in milk samples. The obtained results are discussed and compared with respect to those of inter-laboratory PCR assays and tuberculin skin testing.
Xu, Chen; Zhang, Nan; Huo, Qianyu; Chen, Minghui; Wang, Rengfeng; Liu, Zhili; Li, Xue; Liu, Yunde; Bao, Huijing
2016-04-15
In this article, we discuss the polymerase chain reaction (PCR)-hybridization assay that we developed for high-throughput simultaneous detection and differentiation of Ureaplasma urealyticum and Ureaplasma parvum using one set of primers and two specific DNA probes based on urease gene nucleotide sequence differences. First, U. urealyticum and U. parvum DNA samples were specifically amplified using one set of biotin-labeled primers. Furthermore, amine-modified DNA probes, which can specifically react with U. urealyticum or U. parvum DNA, were covalently immobilized to a DNA-BIND plate surface. The plate was then incubated with the PCR products to facilitate sequence-specific DNA binding. Horseradish peroxidase-streptavidin conjugation and a colorimetric assay were used. Based on the results, the PCR-hybridization assay we developed can specifically differentiate U. urealyticum and U. parvum with high sensitivity (95%) compared with cultivation (72.5%). Hence, this study demonstrates a new method for high-throughput simultaneous differentiation and detection of U. urealyticum and U. parvum with high sensitivity. Based on these observations, the PCR-hybridization assay developed in this study is ideal for detecting and discriminating U. urealyticum and U. parvum in clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.
Noorbazargan, Hassan; Nadji, Seyed Alireza; Samiee, Siamak Mirab; Paryan, Mahdi; Mohammadi-Yeganeh, Samira
2018-04-01
Background Viral load measurement is commonly applicable to monitor HIV infection in patients to determine the number of HIV-RNA in serum samples of individuals. The aim of the present study was to set up a highly specific, sensitive, and reproducible home-brewed Real-time PCR assay based on TaqMan chemistry to quantify HIV-1 RNA genome. Methods In this study, three sets of primer pairs and a TaqMan probe were designed for HIV subtypes conserved sequences. An internal control was included in this assay to evaluate the presence of inhibition. Standard curve and threshold cycle values were determined using in vitro transcribed RNA from int region of HIV-1. A serial dilution of RNA standards was generated by in vitro transcription, from 10 to 10 9 copies/ml to find the sensitivity and the limit of detection (LOD) of the assay and to evaluate its performance in a quantitative RT-PCR assay. Results The assay has a low LOD equivalent to 33.13 copies/ml of HIV-1 RNA and a linear range of detection from 10 to 10 9 copies/ml. The coefficient of variation (CV) for Inter and Intra-assay precision of this in-house HIV Real-time RT-PCR ranged from 0.28 to 2.49% and 0.72 to 4.47%, respectively. The analytical and clinical specificity was 100%. Conclusions The results indicate that the developed method has a suitable specificity and sensitivity and is highly reproducible and cost-benefit. Therefore, it will be useful to monitor HIV infection in plasma samples of individuals.
Farahani, Hamidreza; Ghaznavi-Rad, Ehsanollah; Mondanizadeh, Mahdieh; MirabSamiee, Siamak; Khansarinejad, Behzad
2016-08-01
Accurate and timely diagnosis of acute bacterial meningitis is critical for antimicrobial treatment of patients. Although PCR-based methods have been widely used for the diagnosis of acute meningitis caused by bacterial pathogens, the main disadvantage of these methods is their high cost. This disadvantage has hampered the widespread use of molecular assays in many developing countries. The application of multiplex assays and "in-house" protocols are two main approaches that can reduce the overall cost of a molecular test. In the present study, an internally controlled tetraplex-PCR was developed and validated for the specific detection of Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae in cerebrospinal fluid (CSF) samples. The analysis of a panel of other human pathogens showed no cross-reactivity in the assay. The analytical sensitivity of the in-house assay was 792.3 copies/ml, when all three bacteria were presentin the specimens. This value was calculated as 444.5, 283.7, 127.8 copies/ml when only S. pneumoniae, N. meningitidis and H. influenzae, respectively, were present. To demonstrate the diagnostic performance of the assay, a total of 150 archival CSF samples were tested and compared with a commercial multiplex real-time PCR kit. A diagnostic sensitivity of 92.8% and a specificity of 95.1% were determined for the present tetraplex-PCR assay. The results indicate that the established method is sensitive, specific and cost-effective, and can be used particularly in situations where the high cost of commercial kits prevents the use of molecular methods for the diagnosis of bacterial meningitis. Copyright © 2016 Elsevier Ltd. All rights reserved.
When is it time to get married? Or when should the assay user and the assay developer collaborate?
Swan, S H; Lasley, B L
1991-01-01
Hormone assays are being developed in the laboratory to detect specific molecular markers in nonclinical populations. Epidemiology is increasingly using these assays to improve the precision with which disease processes and exposures can be defined. This growing body of molecular epidemiology requires a high degree of cooperation between the assay developer and the assay user. We draw on our experience in using a sensitive hormone assay for the detection of early pregnancy via urinary human chorionic gonadotropin to illustrate these points. We conclude that this collaborative effort, in addition to making this study possible, has provided unexpected rewards. PMID:1954925
Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.
2015-01-01
There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799
Rumyantseva, Tatiana; Golparian, Daniel; Nilsson, Christian S; Johansson, Emma; Falk, My; Fredlund, Hans; Van Dam, Alje; Guschin, Alexander; Unemo, Magnus
2015-10-01
In this study, we performed an evaluation of the new CE-marked multiplex real-time AmpliSens N.gonorrhoeae/C.trachomatis/M.genitalium/T.vaginalis-MULTIPRIME-FRT PCR assay compared to APTIMA tests, i.e., APTIMA COMBO 2 assay, APTIMA Trichomonas vaginalis assay (FDA-approved), and two different APTIMA Mycoplasma genitalium assays (research use only; one of them only used for discrepancy analysis). Vaginal swabs (n = 209) and first-void urine (FVU) specimens from females (n = 498) and males (n = 554), consecutive attendees (n = 1261) at a dermatovenerological clinic in Sweden, were examined. The sensitivity of the AmpliSens PCR assay for detection of C. trachomatis (6.3% prevalence), M. genitalium (5.7% prevalence), N. gonorrhoeae (0.3% prevalence), and T. vaginalis (0.08% prevalence) was 97.5% (95% confidence interval (CI): 91.2-99.6%), 81.9% (95% CI: 70.7-89.7%), 100% (95% CI: 40.2-100%) and 100% (95% CI: 16.5-100%), respectively. The specificity of the AmpliSens PCR assay was 100% (95% CI: 99.6-100%) for all agents. The analytical sensitivity and specificity for N. gonorrhoeae detection was excellent, i.e., 55 international gonococcal strains detected and 135 isolates of 13 non-gonococcal Neisseria species were negative. In conclusion, the multiplex real-time AmpliSens N.gonorrhoeae/C.trachomatis/M.genitalium/T.vaginalis-MULTIPRIME-FRT PCR assay demonstrated high sensitivity and excellent specificity for the detection of C. trachomatis, N. gonorrhoeae, and T. vaginalis, and excellent specificity but suboptimal sensitivity for M. genitalium detection. © 2015 APMIS. Published by John Wiley & Sons Ltd.
Cirelli, Kimberly M.; Dan, Jennifer M.; Morou, Antigoni; Daigneault, Audrey; Brassard, Nathalie; Silvestri, Guido; Routy, Jean-Pierre; Havenar-Daughton, Colin; Crotty, Shane
2017-01-01
The identification and study of antigen-specific CD4 T cells, both in peripheral blood and in tissues, is key for a broad range of immunological research, including vaccine responses and infectious diseases. Detection of these cells is hampered by both their rarity and their heterogeneity, in particular with regards to cytokine secretion profiles. These factors prevent the identification of the total pool of antigen-specific CD4 T cells by classical methods. We have developed assays for the highly sensitive detection of such cells by measuring the upregulation of surface activation induced markers (AIM). Here, we compare two such assays based on concurrent expression of CD69 plus CD40L (CD154) or expression of OX40 plus CD25, and we develop additional AIM assays based on OX40 plus PD-L1 or 4-1BB. We compare the relative sensitivity of these assays for detection of vaccine and natural infection-induced CD4 T cell responses and show that these assays identify distinct, but overlapping populations of antigen-specific CD4 T cells, a subpopulation of which can also be detected on the basis of cytokine synthesis. Bystander activation had minimal effect on AIM markers. However, some T regulatory cells upregulate CD25 upon antigen stimulation. We therefore validated AIM assays designed to exclude most T regulatory cells, for both human and non-human primate (NHP, Macaca mulatta) studies. Overall, through head-to-head comparisons and methodological improvements, we show that AIM assays represent a sensitive and valuable method for the detection of antigen-specific CD4 T cells. PMID:29065175
Reiss, Samantha; Baxter, Amy E; Cirelli, Kimberly M; Dan, Jennifer M; Morou, Antigoni; Daigneault, Audrey; Brassard, Nathalie; Silvestri, Guido; Routy, Jean-Pierre; Havenar-Daughton, Colin; Crotty, Shane; Kaufmann, Daniel E
2017-01-01
The identification and study of antigen-specific CD4 T cells, both in peripheral blood and in tissues, is key for a broad range of immunological research, including vaccine responses and infectious diseases. Detection of these cells is hampered by both their rarity and their heterogeneity, in particular with regards to cytokine secretion profiles. These factors prevent the identification of the total pool of antigen-specific CD4 T cells by classical methods. We have developed assays for the highly sensitive detection of such cells by measuring the upregulation of surface activation induced markers (AIM). Here, we compare two such assays based on concurrent expression of CD69 plus CD40L (CD154) or expression of OX40 plus CD25, and we develop additional AIM assays based on OX40 plus PD-L1 or 4-1BB. We compare the relative sensitivity of these assays for detection of vaccine and natural infection-induced CD4 T cell responses and show that these assays identify distinct, but overlapping populations of antigen-specific CD4 T cells, a subpopulation of which can also be detected on the basis of cytokine synthesis. Bystander activation had minimal effect on AIM markers. However, some T regulatory cells upregulate CD25 upon antigen stimulation. We therefore validated AIM assays designed to exclude most T regulatory cells, for both human and non-human primate (NHP, Macaca mulatta) studies. Overall, through head-to-head comparisons and methodological improvements, we show that AIM assays represent a sensitive and valuable method for the detection of antigen-specific CD4 T cells.
Anticoagulant Effect of Sugammadex: Just an In Vitro Artifact.
Dirkmann, Daniel; Britten, Martin W; Pauling, Henning; Weidle, Juliane; Volbracht, Lothar; Görlinger, Klaus; Peters, Jürgen
2016-06-01
Sugammadex prolongs activated partial thromboplastin time (aPTT) and prothrombin time (PT) suggestive of anticoagulant effects. To pinpoint its presumed anticoagulant site of action, the authors assessed Sugammadex's impact on a panel of coagulation assays. Sugammadex, Rocuronium, Sugammadex and Rocuronium combined, or saline were added to blood samples from healthy volunteers and analyzed using plasmatic (i.e., aPTT, thrombin time, and fibrinogen concentration) (n = 8 each), PT (quick), activities of plasmatic coagulation factors, and whole blood (extrinsically and intrinsically activated thromboelastometry) assays (n = 18 each). Furthermore, dose-dependent effects of Sugammadex were also assessed (n = 18 each) in diluted Russel viper venom time (DRVVT) assays with low (DRVVT1) and high (DRVVT2) phospholipid concentrations and in a highly phospholipid-sensitive aPTT assay. Sugammadex increased PT (+9.1%; P < 0.0001), aPTT (+13.1%; P = 0.0002), and clotting time in extrinsically (+33.1%; P = 0.0021) and intrinsically (+22.4%; P < 0.0001) activated thromboelastometric assays. Furthermore, activities of factors VIII, IX, XI, and XII decreased (-7%, P = 0.009; -7.8%, P < 0.0001; -6.9%, P < 0.0001; and -4.3%, P = 0.011, respectively). Sugammadex dose-dependently prolonged both DRVVT1 and the highly phospholipid-sensitive aPTT assays, but additional phospholipids in the DRVVT2 assay almost abolished these prolongations. Thrombin time, a thromboelastometric thrombin generation assay, clot firmness, clot lysis, fibrinogen concentration, and activities of other coagulation factors were unaltered. Rocuronium, Sugammadex and Rocuronium combined, and saline exerted no effects. Sugammadex significantly affects various coagulation assays, but this is explainable by an apparent phospholipid-binding effect, suggesting that Sugammadex`s anticoagulant effects are likely an in vitro artifact.
Gaber, Rok; Majerle, Andreja; Jerala, Roman; Benčina, Mojca
2013-01-01
To effectively fight against the human immunodeficiency virus infection/acquired immunodeficiency syndrome (HIV/AIDS) epidemic, ongoing development of novel HIV protease inhibitors is required. Inexpensive high-throughput screening assays are needed to quickly scan large sets of chemicals for potential inhibitors. We have developed a Förster resonance energy transfer (FRET)-based, HIV protease-sensitive sensor using a combination of a fluorescent protein pair, namely mCerulean and mCitrine. Through extensive in vitro characterization, we show that the FRET-HIV sensor can be used in HIV protease screening assays. Furthermore, we have used the FRET-HIV sensor for intracellular quantitative detection of HIV protease activity in living cells, which more closely resembles an actual viral infection than an in vitro assay. We have developed a high-throughput method that employs a ratiometric flow cytometry for analyzing large populations of cells that express the FRET-HIV sensor. The method enables FRET measurement of single cells with high sensitivity and speed and should be used when subpopulation-specific intracellular activity of HIV protease needs to be estimated. In addition, we have used a confocal microscopy sensitized emission FRET technique to evaluate the usefulness of the FRET-HIV sensor for spatiotemporal detection of intracellular HIV protease activity. PMID:24287545
Stanley, Joanna L; Lincoln, Rachael J; Brown, Terry A; McDonald, Louise M; Dawson, Gerard R; Reynolds, David S
2005-05-01
The mouse rotarod test of motor coordination/sedation is commonly used to predict clinical sedation caused by novel drugs. However, past experience suggests that it lacks the desired degree of sensitivity to be predictive of effects in humans. For example, the benzodiazepine, bretazenil, showed little impairment of mouse rotarod performance, but marked sedation in humans. The aim of the present study was to assess whether the mouse beam walking assay demonstrates: (i) an increased sensitivity over the rotarod and (ii) an increased ability to predict clinically sedative doses of benzodiazepines. The study compared the effects of the full benzodiazepine agonists, diazepam and lorazepam, and the partial agonist, bretazenil, on the mouse rotarod and beam walking assays. Diazepam and lorazepam significantly impaired rotarod performance, although relatively high GABA-A receptor occupancy was required (72% and 93%, respectively), whereas beam walking performance was significantly affected at approximately 30% receptor occupancy. Bretazenil produced significant deficits at 90% and 53% receptor occupancy on the rotarod and beam walking assays, respectively. The results suggest that the mouse beam walking assay is a more sensitive tool for determining benzodiazepine-induced motor coordination deficits than the rotarod. Furthermore, the GABA-A receptor occupancy values at which significant deficits were determined in the beam walking assay are comparable with those observed in clinical positron emission tomography studies using sedative doses of benzodiazepines. These data suggest that the beam walking assay may be able to more accurately predict the clinically sedative doses of novel benzodiazepine-like drugs.
Ambagala, A; Fisher, M; Goolia, M; Nfon, C; Furukawa-Stoffer, T; Ortega Polo, R; Lung, O
2017-10-01
Foot-and-mouth disease (FMD) is a highly contagious viral disease of cloven-hoofed animals, which can decimate the livestock industry and economy of countries previously free of this disease. Rapid detection of foot-and-mouth disease virus (FMDV) is critical to containing an FMD outbreak. Availability of a rapid, highly sensitive and specific, yet simple and field-deployable assay would support local decision-making during an FMDV outbreak. Here we report validation of a novel reverse transcription-insulated isothermal PCR (RT-iiPCR) assay that can be performed on a commercially available, compact and portable POCKIT ™ analyser that automatically analyses data and displays '+' or '-' results. The FMDV RT-iiPCR assay targets the 3D region of the FMDV genome and was capable of detecting 9 copies of in vitro-transcribed RNA standard with 95% confidence. It accurately identified 63 FMDV strains belonging to all seven serotypes and showed no cross-reactivity with viruses causing similar clinical diseases in cloven-hoofed animals. The assay was able to identify FMDV RNA in multiple sample types including oral, nasal and lesion swabs, epithelial tissue suspensions, vesicular and oral fluid samples, even before the appearance of clinical signs. Clinical sensitivity of the assay was comparable or slightly higher than the laboratory-based real-time RT-PCR assay in use. The assay was able to detect FMDV RNA in vesicular fluid samples without nucleic acid extraction. For RNA extraction from more complex sample types, a commercially available taco ™ mini transportable magnetic bead-based, automated extraction system was used. This assay provides a potentially useful field-deployable diagnostic tool for rapid detection of FMDV in an outbreak in FMD-free countries or for routine diagnostics in endemic countries with less structured laboratory systems. © 2016 Her Majesty the Queen in Right of Canada.
Aitichou, Mohamed; Saleh, Sharron; Kyusung, Park; Huggins, John; O'Guinn, Monica; Jahrling, Peter; Ibrahim, Sofi
2008-11-01
A real-time, multiplexed polymerase chain reaction (PCR) assay based on dried PCR reagents was developed. Only variola virus could be specifically detected by a FAM (6-carboxyfluorescein)-labeled probe while camelpox, cowpox, monkeypox and vaccinia viruses could be detected by a TET (6-carboxytetramethylrhodamine)-labeled probe in a single PCR reaction. Approximately 25 copies of cloned variola virus DNA and 50 copies of genomic orthopoxviruses DNA could be detected with high reproducibility. The assay exhibited a dynamic range of seven orders of magnitude with a correlation coefficient value greater than 0.97. The sensitivity and specificity of the assay, as determined from 100 samples that contained nucleic acids from a multitude of bacterial and viral species were 96% and 98%, respectively. The limit of detection, sensitivity and specificity of the assay were comparable to standard real-time PCR assays with wet reagents. Employing a multiplexed format in this assay allows simultaneous discrimination of the variola virus from other closely related orthopoxviruses. Furthermore, the implementation of dried reagents in real-time PCR assays is an important step towards simplifying such assays and allowing their use in areas where cold storage is not easily accessible.
Peng, Zhiyong; Young, Brandon; Baird, Alison E; Soper, Steven A
2013-08-20
Expression analysis of mRNAs transcribed from certain genes can be used as important sources of biomarkers for in vitro diagnostics. While the use of reverse transcription quantitative PCR (RT-qPCR) can provide excellent analytical sensitivity for monitoring transcript numbers, more sensitive approaches for expression analysis that can report results in near real-time are needed for many critical applications. We report a novel assay that can provide exquisite limits-of-quantitation and consists of reverse transcription (RT) followed by a ligase detection reaction (LDR) with single-pair fluorescence resonance energy transfer (spFRET) to provide digital readout through molecular counting. For this assay, no PCR was employed, which enabled short assay turnaround times. To facilitate implementation of the assay, a cyclic olefin copolymer (COC) microchip, which was fabricated using hot embossing, was employed to carry out the LDR in a continuous flow format with online single-molecule detection following the LDR. As demonstrators of the assay's utility, MMP-7 mRNA was expression profiled from several colorectal cancer cell lines. It was found that the RT-LDR/spFRET assay produced highly linear calibration plots even in the low copy number regime. Comparison to RT-qPCR indicated a better linearity over the low copy number range investigated (10-10,000 copies) with an R(2) = 0.9995 for RT-LDR/spFRET and R(2) = 0.98 for RT-qPCR. In addition, differentiating between copy numbers of 10 and 50 could be performed with higher confidence using RT-LDR/spFRET. To demonstrate the short assay turnaround times obtainable using the RT-LDR/spFRET assay, a two thermal cycle LDR was carried out on amphiphysin gene transcripts that can serve as important diagnostic markers for ischemic stroke. The ability to supply diagnostic information on possible stroke events in short turnaround times using RT-LDR/spFRET will enable clinicians to treat patients effectively with appropriate time-sensitive therapeutics.
Peng, Zhiyong; Young, Brandon; Baird, Alison E.; Soper, Steven A.
2013-01-01
Expression analysis of mRNAs transcribed from certain genes can be used as important sources of biomarkers for in vitro diagnostics. While the use of reverse transcription quantitative PCR (RT-qPCR) can provide excellent analytical sensitivity for monitoring transcript numbers, more sensitive approaches for expression analysis that can report results in near real-time are needed for many critical applications. We report a novel assay that can provide exquisite limits-of-quantitation and consists of reverse transcription (RT) followed by a ligase detection reaction (LDR) with single-pair fluorescence resonance energy transfer (spFRET) to provide digital readout through molecular counting. For this assay, no PCR was employed, which enabled short assay turnaround times. To facilitate implementation of the assay, a cyclic olefin copolymer (COC) microchip, which was fabricated using hot embossing, was employed to carry out the LDR in a continuous flow format with on-line single-molecule detection following the LDR. As demonstrators of the assay's utility, MMP-7 mRNA was expression profiled from several colorectal cancer cell lines. It was found that the RT-LDR/spFRET assay produced highly linear calibration plots even in the low copy number regime. Comparison to RT-qPCR indicated a better linearity over the low copy number range investigated (10 − 10,000 copies) with an R2 = 0.9995 for RT-LDR/spFRET and R2 = 0.98 for RT-qPCR. In addition, differentiating between copy numbers of 10 and 50 could be performed with higher confidence using RT-LDR/spFRET. To demonstrate the short assay turnaround times obtainable using the RT-LDR/spFRET assay, a 2 thermal cycle LDR was carried out on amphiphysin gene transcripts that can serve as important diagnostic markers for ischemic stroke. The ability to supply diagnostic information on possible stroke events in short turnaround times using RT-LDR/spFRET will enable clinicians to treat patients effectively with appropriate time-sensitive therapeutics. PMID:23869556
Nelson, Julie A E; Hawkins, J Tyler; Schanz, Maria; Mollan, Katie; Miller, Melissa B; Schmitz, John L; Fiscus, Susan A
2014-08-01
The current gold standard for infant diagnosis of HIV-1 is the Roche Amplicor Qualitative DNA assay, but it is being phased out. Compare the Abbott qualitative assay and the Gen-Probe Aptima assay to the gold standard Roche DNA assay using dried blood spots (DBS). The Gen-Probe Aptima and Abbott qualitative HIV-1 assays were compared to the Roche DNA assay for early infant diagnosis. Specificity and sensitivity were determined for the three assays using DBS from 50 HIV-exposed uninfected infants and 269 HIV-1 infected adults from North Carolina, respectively. All of the negative and 151 of the positive DBS had valid results on the 3 different assays, and an additional 118 positive DBS had valid results on the Roche DNA and Aptima assays. All three assays were very specific. The Roche DNA assay was the most sensitive (96.7%) over a wide range of HIV PVL, including samples with PVL<400 copies/ml. Restricted to samples with PVL>400 copies/ml, the Gen-Probe Aptima assay had sensitivity (96.5%) comparable to the Roche DNA assay (98.8%). The Abbott Qualitative assay was the least sensitive and only had sensitivity above 95% among samples with PVL over 1000 copies/ml. The Abbott HIV-1 Qualitative assay was not as sensitive as the comparator assays, so it would not be a useful replacement assay, especially for infants taking antiretroviral prophylaxis. The Gen-Probe Aptima assay is an adequate replacement option for infant diagnosis using DBS. Copyright © 2014 Elsevier B.V. All rights reserved.
A simple and sensitive enzymatic method for cholesterol quantification in macrophages and foam cells
Robinet, Peggy; Wang, Zeneng; Hazen, Stanley L.; Smith, Jonathan D.
2010-01-01
A precise and sensitive method for measuring cellular free and esterified cholesterol is required in order to perform studies of macrophage cholesterol loading, metabolism, storage, and efflux. Until now, the use of an enzymatic cholesterol assay, commonly used for aqueous phase plasma cholesterol assays, has not been optimized for use with solid phase samples such as cells, due to inefficient solubilization of total cholesterol in enzyme compatible solvents. We present an efficient solubilization protocol compatible with an enzymatic cholesterol assay that does not require chemical saponification or chromatographic separation. Another issue with enzyme compatible solvents is the presence of endogenous peroxides that interfere with the enzymatic cholesterol assay. We overcame this obstacle by pretreatment of the reaction solution with the enzyme catalase, which consumed endogenous peroxides resulting in reduced background and increased sensitivity in our method. Finally, we demonstrated that this method for cholesterol quantification in macrophages yields results that are comparable to those measured by stable isotope dilution gas chromatography with mass spectrometry detection. In conclusion, we describe a sensitive, simple, and high-throughput enzymatic method to quantify cholesterol in complex matrices such as cells. PMID:20688754
Angkasekwinai, Nasikarn; Atkins, Erin H.; Romero, Sofia; Grieco, John; Chao, Chien Chung; Ching, Wei Mei
2014-01-01
Reliable laboratory testing is of great importance to detect Bartonella bacilliformis infection. We evaluated the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) using recombinant protein Pap31 (rPap31) for the detection of antibodies against B. bacilliformis as compared with immunofluorescent assay (IFA). Of the 302 sera collected between 1997 and 2000 among an at-risk Peruvian population, 103 and 34 samples tested positive for IFA-immunoglobulin G (IgG) and IFA-IgM, respectively. By using Youden's index, the cutoff values of ELISA-IgG at 0.915 gave a sensitivity of 84.5% and specificity of 94%. The cutoff values of ELISA-IgM at 0.634 gave a sensitivity of 88.2% and specificity of 85.1%. Using latent class analysis, estimates of sensitivity and specificity of almost all the assays were slightly higher than those of a conventional method of calculation. The test is proved beneficial for discriminating between infected and non-infected individuals with the advantage of low-cost and high-throughput capability. PMID:24515944
Expediting SRM assay development for large-scale targeted proteomics experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Chaochao; Shi, Tujin; Brown, Joseph N.
2014-08-22
Due to their high sensitivity and specificity, targeted proteomics measurements, e.g. selected reaction monitoring (SRM), are becoming increasingly popular for biological and translational applications. Selection of optimal transitions and optimization of collision energy (CE) are important assay development steps for achieving sensitive detection and accurate quantification; however, these steps can be labor-intensive, especially for large-scale applications. Herein, we explored several options for accelerating SRM assay development evaluated in the context of a relatively large set of 215 synthetic peptide targets. We first showed that HCD fragmentation is very similar to CID in triple quadrupole (QQQ) instrumentation, and by selection ofmore » top six y fragment ions from HCD spectra, >86% of top transitions optimized from direct infusion on QQQ instrument are covered. We also demonstrated that the CE calculated by existing prediction tools was less accurate for +3 precursors, and a significant increase in intensity for transitions could be obtained using a new CE prediction equation constructed from the present experimental data. Overall, our study illustrates the feasibility of expediting the development of larger numbers of high-sensitivity SRM assays through automation of transitions selection and accurate prediction of optimal CE to improve both SRM throughput and measurement quality.« less
Lang, Jillian M.; Langlois, Paul; Nguyen, Marian Hanna R.; Triplett, Lindsay R.; Purdie, Laura; Holton, Timothy A.; Djikeng, Appolinaire; Vera Cruz, Casiana M.; Verdier, Valérie
2014-01-01
Molecular diagnostics for crop diseases can enhance food security by enabling the rapid identification of threatening pathogens and providing critical information for the deployment of disease management strategies. Loop-mediated isothermal amplification (LAMP) is a PCR-based tool that allows the rapid, highly specific amplification of target DNA sequences at a single temperature and is thus ideal for field-level diagnosis of plant diseases. We developed primers highly specific for two globally important rice pathogens, Xanthomonas oryzae pv. oryzae, the causal agent of bacterial blight (BB) disease, and X. oryzae pv. oryzicola, the causal agent of bacterial leaf streak disease (BLS), for use in reliable, sensitive LAMP assays. In addition to pathovar distinction, two assays that differentiate X. oryzae pv. oryzae by African or Asian lineage were developed. Using these LAMP primer sets, the presence of each pathogen was detected from DNA and bacterial cells, as well as leaf and seed samples. Thresholds of detection for all assays were consistently 104 to 105 CFU ml−1, while genomic DNA thresholds were between 1 pg and 10 fg. Use of the unique sequences combined with the LAMP assay provides a sensitive, accurate, rapid, simple, and inexpensive protocol to detect both BB and BLS pathogens. PMID:24837384
IRAS: High-Throughput Identification of Novel Alternative Splicing Regulators.
Zheng, S
2016-01-01
Alternative splicing is a fundamental regulatory process of gene expression. Defects in alternative splicing can lead to various diseases, and modification of disease-causing splicing events presents great therapeutic promise. Splicing outcome is commonly affected by extracellular stimuli and signaling cascades that converge on RNA-binding splicing regulators. These trans-acting factors recognize cis-elements in pre-mRNA transcripts to affect spliceosome assembly and splice site choices. Identification of these splicing regulators and/or upstream modulators has been difficult and traditionally done by piecemeal. High-throughput screening strategies to find multiple regulators of exon splicing have great potential to accelerate the discovery process, but typically confront low sensitivity and low specificity of screening assays. Here we describe a unique screening strategy, IRAS (identifying regulators of alternative splicing), using a pair of dual-output minigene reporters to allow for sensitive detection of exon splicing changes. Each dual-output reporter produces green fluorescent protein (GFP) and red fluorescent protein (RFP) fluorescent signals to assay the two spliced isoforms exclusively. The two complementary minigene reporters alter GFP/RFP output ratios in the opposite direction in response to splicing change. Applying IRAS in cell-based high-throughput screens allows sensitive and specific identification of splicing regulators and modulators for any alternative exons of interest. In comparison to previous high-throughput screening methods, IRAS substantially enhances the specificity of the screening assay. This strategy significantly eliminates false positives without sacrificing sensitive identification of true regulators of splicing. © 2016 Elsevier Inc. All rights reserved.
Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.
Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja
2016-11-01
High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.
Xiao, Zhujun; Li, Bingsheng; Wang, Guozhen; Zhu, Weisi; Wang, Zhongqiu; Lin, Jinfeng; Xu, Angao; Wang, Xinying
2014-04-20
Methylation-sensitive high-resolution melting (MS-HRM) is a new technique for assaying DNA methylation, but its feasibility for assaying stool in patients with colorectal cancer (CRC) is unknown. First, the MS-HRM and methylation-specific PCR (MSP) detection limits were tested. Second, the methylation statuses of SFRP2 and VIM were analyzed in stool samples by MS-HRM, and in matching tumor and normal colon tissues via bisulfite sequencing PCR (BSP). Third, a case-control study evaluated the diagnostic sensitivity and specificity of MS-HRM relative to results obtained with MSP and the fecal immunochemical test (FIT). Finally, the linearity and reproducibility of MS-HRM were assessed. The detection limits of MS-HRM and MSP were 1% and 5%, respectively. The diagnostic sensitivities of MS-HRM (87.3%, 55/63) in stool and BSP in matching tumor tissue (92.1%, 58/63) were highly consistent (κ=0.744). The MS-HRM assay detected 92.5% (37/40) methylation in CRCs, 94.4% (34/36) in advanced adenomas, and 8.8% (5/57) in normal controls. The results of MS-HRM analysis were stable and reliable and showed fairly good linearity for both SFRP2 (P<0.001, R(2)=0.957) and VIM (P<0.001, R(2)=0.954). MS-HRM shows potential for CRC screening. Copyright © 2014 Elsevier B.V. All rights reserved.
Evaluation of sensitivity of TaqMan RT-PCR for rubella virus detection in clinical specimens.
Okamoto, Kiyoko; Mori, Yoshio; Komagome, Rika; Nagano, Hideki; Miyoshi, Masahiro; Okano, Motohiko; Aoki, Yoko; Ogura, Atsushi; Hotta, Chiemi; Ogawa, Tomoko; Saikusa, Miwako; Kodama, Hiroe; Yasui, Yoshihiro; Minagawa, Hiroko; Kurata, Takako; Kanbayashi, Daiki; Kase, Tetsuo; Murata, Sachiko; Shirabe, Komei; Hamasaki, Mitsuhiro; Kato, Takashi; Otsuki, Noriyuki; Sakata, Masafumi; Komase, Katsuhiro; Takeda, Makoto
2016-07-01
An easy and reliable assay for detection of the rubella virus is required to strengthen rubella surveillance. Although a TaqMan RT-PCR assay for detection of the rubella virus has been established in Japan, its utility for diagnostic purposes has not been tested. To allow introduction of the TaqMan RT-PCR into the rubella surveillance system in Japan, the sensitivity of the assay was determined using representative strains for all genotypes and clinical specimens. The detection limits of the method for individual genotypes were examined using viral RNA extracted from 13 representative strains. The assay was also tested at 10 prefectural laboratories in Japan, designated as local reference laboratories for measles and rubella, to allow nationwide application of the assay. The detection limits and amplification efficiencies of the assay were similar among all the representative strains of the 13 genotypes. The TaqMan RT-PCR could detect approximately 90% of throat swab and urine samples taken up to 5days of illness. These samples were determined positive by a highly sensitive nested RT-PCR. The TaqMan RT-PCR could detect at least 10 pfu of rubella virus. Although the sensitivity was somewhat lower than that of the conventional nested RT-PCR, the TaqMan RT-PCR could be more practical to routine tests for rubella laboratory diagnosis and detection in view of the rapid response and reducing risks of contamination. Copyright © 2016 Elsevier B.V. All rights reserved.
Haleyur Giri Setty, Mohan Kumar; Liu, Jikun; Mahtani, Prerna; Zhang, Panhe; Du, Bingchen; Ragupathy, Viswanath; Devadas, Krishnakumar; Hewlett, Indira K
2016-06-01
Accurate detection and quantification of HIV-1 group O viruses have been challenging for currently available HIV assays. We have developed a novel time-resolved fluorescence (TRF) europium nanoparticle immunoassay for HIV-1 group O detection using a conventional microplate enzyme-linked immunosorbent assay (ELISA) and a microchip platform. We screened several antibodies for optimal reactivity with several HIV-1 group O strains and identified antibodies that can detect all the strains of HIV-1 group O that were available for testing. The antibodies were used to develop a conventional ELISA format assay and an in-house developed europium nanoparticle-based assay for sensitivity. The method was evaluated on both microwell plate and microchip platforms. We identified two specific and sensitive antibodies among the six we screened. The antibodies, C65691 and ANT-152, were able to quantify 15 and detect all 17 group O viruses, respectively, as they were broadly cross-reactive with all HIV-1 group O strains and yielded better signals compared with other antibodies. We have developed a sensitive assay that reflects the actual viral load in group O samples by using an appropriate combination of p24 antibodies that enhance group O detection and a highly sensitive TRF-based europium nanoparticle for detection. The combination of ANT-152 and C65690M in the ratio 3:1 was able to give significantly higher signals in our europium-based assay compared with using any single antibody.
Sensitive Microplate Assay for Detection of Bactericidal Antibodies to Vibrio cholerae O139
Attridge, Stephen R.; Johansson, Camilla; Trach, Dang D.; Qadri, Firdausi; Svennerholm, Ann-Mari
2002-01-01
A microplate assay for the detection of bactericidal antibodies to Vibrio cholerae O139 is described. The assay is sensitive, highly reproducible, specific, and convenient to perform. It has been used to demonstrate the induction of serum bactericidal antibodies in Vietnamese recipients of an oral, inactivated, bivalent O1/O139 vaccine, as well as in Bangladeshi patients with O139 disease. In both study groups there was a significant inverse correlation between the preexposure level of antibodies in serum and the magnitude of the subsequent bactericidal response. Although infection generated stronger responses than vaccination, the proportion of responders was similar among individuals with low background titers. PMID:11874883
Multiplex real-time PCR assay for detection of pathogenic Vibrio parahaemolyticus strains.
He, Peiyan; Chen, Zhongwen; Luo, Jianyong; Wang, Henghui; Yan, Yong; Chen, Lixia; Gao, Wenjie
2014-01-01
Foodborne disease caused by pathogenic Vibrio parahaemolyticus has become a serious public health problem in many countries. Rapid diagnosis and the identification of pathogenic V. parahaemolyticus are very important in the context of public health. In this study, an EvaGreen-based multiplex real-time PCR assay was established for the detection of pathogenic V. parahaemolyticus. This assay targeted three genetic markers of V. parahaemolyticus (species-specific gene toxR and virulence genes tdh and trh). The assay could unambiguously identify pathogenic V. parahaemolyticus with a minimum detection limit of 1.4 pg genomic DNA per reaction (concentration giving a positive multiplex real-time PCR result in 95% of samples). The specificity of the assay was evaluated using 72 strains of V. parahaemolyticus and other bacteria. A validation of the assay with clinical samples confirmed its sensitivity and specificity. Our data suggest the newly established multiplex real-time PCR assay is practical, cost-effective, specific, sensitive and capable of high-throughput detection of pathogenic V. parahaemolyticus. Copyright © 2014. Published by Elsevier Ltd.
Kho, S L; Chua, K H; George, E; Tan, J A M A
2013-07-15
Beta-thalassemia is a life-threatening inherited blood disorder. Rapid characterization of β-globin gene mutations is necessary because of the high frequency of Malaysian β-thalassemia carriers. A combination real-time polymerase chain reaction genotyping assay using TaqMan probes was developed to confirm β-globin gene mutations. In this study, primers and probes were designed to specifically identify 8 common β-thalassemia mutations in the Malaysian Malay and Chinese ethnic groups using the Primer Express software. "Blind tests" using DNA samples from healthy individuals and β-thalassemia patients with different genotypes were performed to determine the specificity and sensitivity of this newly designed assay. Our results showed 100% sensitivity and specificity for this novel assay. In conclusion, the TaqMan genotyping assay is a straightforward assay that allows detection of β-globin gene mutations in less than 40 min. The simplicity and reproducibility of the TaqMan genotyping assay permit its use in laboratories as a rapid and cost-effective diagnostic tool for confirmation of common β-thalassemia mutations in Malaysia.
Putsathit, Papanin; Morgan, Justin; Bradford, Damien; Engelhardt, Nelly; Riley, Thomas V
2015-02-01
The Becton Dickinson (BD) PCR-based GeneOhm Cdiff assay has demonstrated a high sensitivity and specificity for detecting Clostridium difficile. Recently, the BD Max platform, using the same principles as BD GeneOhm, has become available in Australia. This study aimed to investigate the sensitivity and specificity of BD Max Cdiff assay for the detection of toxigenic C. difficile in an Australian setting. Between December 2013 and January 2014, 406 stool specimens from 349 patients were analysed with the BD Max Cdiff assay. Direct and enrichment toxigenic culture were performed on bioMérieux ChromID C. difficile agar as a reference method. isolates from specimens with discrepant results were further analysed with an in-house PCR to detect the presence of toxin genes. The overall prevalence of toxigenic C. difficile was 7.2%. Concordance between the BD Max assay and enrichment culture was 98.5%. The sensitivity, specificity, positive predictive value and negative predictive value for the BD Max Cdiff assay were 95.5%, 99.0%, 87.5% and 99.7%, respectively, when compared to direct culture, and 91.7%, 99.0%, 88.0% and 99.4%, respectively, when compared to enrichment culture. The new BD Max Cdiff assay appeared to be an excellent platform for rapid and accurate detection of toxigenic C. difficile.
Gilhuley, Kathleen; Cianciminio-Bordelon, Diane; Tang, Yi-Wei
2012-01-01
We compared the performance characteristics of culture and the Cepheid Xpert vanA assay for routine surveillance of vancomycin-resistant enterococci (VRE) from rectal swabs in patients at high risk for VRE carriage. The Cepheid Xpert vanA assay had a limit of detection of 100 CFU/ml and correctly detected 101 well-characterized clinical VRE isolates with no cross-reactivity in 27 non-VRE and related culture isolates. The clinical sensitivity, specificity, positive predictive value, and negative predictive value of the Xpert vanA PCR assay were 100%, 96.9%, 91.3%, and 100%, respectively, when tested on 300 consecutively collected rectal swabs. This assay provides excellent predictive values for prompt identification of VRE-colonized patients in hospitals with relatively high rates of VRE carriage. PMID:22972822
Yang, Yang; Qin, Xiaodong; Sun, Yingjun; Chen, Ting; Zhang, Zhidong
2016-12-01
A novel fluorescent probe-based real-time reverse transcription recombinase polymerase amplification (real-time RT-RPA) assay was developed for rapid detection of highly pathogenic type 2 porcine reproductive and respiratory syndrome virus (HP-PRRSV). The sensitivity analysis showed that the detection limit of RPA was 70 copies of HP-PRRSV RNA/reaction. The real-time RT-RPA highly specific amplified HP-PRRSV with no cross-reaction with classic PRRSV, classic swine fever virus, pseudorabies virus, and foot-and-mouth disease virus. Assessment with 125 clinical samples showed that the developed real-time RT-RPA assay was well correlated with real-time RT-qPCR assays for detection of HP-PRRSV. These results suggest that the developed real-time RT-RPA assay is suitable for rapid detection of HP-PRRSV.
Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).
Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J
2017-11-01
Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.
Chemotyping the distribution of vitamin D metabolites in human serum
NASA Astrophysics Data System (ADS)
Müller, Miriam J.; Stokes, Caroline S.; Lammert, Frank; Volmer, Dietrich A.
2016-02-01
Most studies examining the relationships between vitamin D and disease or health focus on the main 25-hydroxyvitamin D3 (25(OH)D3) metabolite, thus potentially overlooking contributions and dynamic effects of other vitamin D metabolites, the crucial roles of several of which have been previously demonstrated. The ideal assay would determine all relevant high and low-abundant vitamin D species simultaneously. We describe a sensitive quantitative assay for determining the chemotypes of vitamin D metabolites from serum after derivatisation and ultra-high performance liquid chromatography-electrospray ionisation-tandem mass spectrometry (UHPLC-ESI-MS/MS). We performed a validation according to the ‘FDA Guidance for Industry Bioanalytical Method Validation’. The proof-of-concept of the method was then demonstrated by following the metabolite concentrations in patients with chronic liver diseases (CLD) during the course of a vitamin D supplementation study. The new quantitative profiling assay provided highly sensitive, precise and accurate chemotypes of the vitamin D metabolic process rather than the usually determined 25(OH)D3 concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Gai; Nash, Peter J.; Johnson, Britney
The 2014 Ebola outbreak in West Africa, the largest outbreak on record, highlighted the need for novel approaches to therapeutics targeting Ebola virus (EBOV). Within the EBOV replication complex, the interaction between polymerase cofactor, viral protein 35 (VP35), and nucleoprotein (NP) is critical for viral RNA synthesis. We recently identified a peptide at the N-terminus of VP35 (termed NPBP) that is sufficient for interaction with NP and suppresses EBOV replication, suggesting that the NPBP binding pocket can serve as a potential drug target. Here we describe the development and validation of a sensitive high-throughput screen (HTS) using a fluorescence polarizationmore » assay. Initial hits from this HTS include the FDA-approved compound tolcapone, whose potency against EBOV infection was validated in a nonfluorescent secondary assay. High conservation of the NP–VP35 interface among filoviruses suggests that this assay has the capacity to identify pan-filoviral inhibitors for development as antivirals.« less
Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa
2017-01-17
Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
Doped colorimetric assay liposomes
Charych, Deborah; Stevens, Raymond C.
2001-01-01
The present invention provides compositions comprising colorimetric assay liposomes. The present invention also provides methods for producing colorimetric liposomes and calorimetric liposome assay systems. In preferred embodiments, these calorimetric liposome systems provide high levels of sensitivity through the use of dopant molecules. As these dopants allow the controlled destabilization of the liposome structure, upon exposure of the doped liposomes to analyte(s) of interest, the indicator color change is facilitated and more easily recognized.
Comparison of functional assays used in the clinical development of a placental malaria vaccine.
Pehrson, Caroline; Heno, Kristine K; Adams, Yvonne; Resende, Mafalda; Mathiesen, Line; Soegaard, Max; de Jongh, Willem A; Theander, Thor G; Salanti, Ali; Nielsen, Morten A
2017-01-23
Malaria in pregnancy is associated with significant morbidity in pregnant women and their offspring. Plasmodium falciparum infected erythrocytes (IE) express VAR2CSA that mediates binding to chondroitin sulphate A (CSA) in the placenta. Two VAR2CSA-based vaccines for placental malaria are in clinical development. The purpose of this study was to evaluate the robustness and comparability of binding inhibition assays used in the clinical development of placental malaria vaccines. The ability of sera from animals immunised with different VAR2CSA constructs to inhibit IE binding to CSA was investigated in three in vitro assays using 96-well plates, petri dishes, capillary flow and an ex vivo placental perfusion assay. The inter-assay variation was not uniform between assays and ranged from above ten-fold in the flow assay to two-fold in the perfusion assay. The intra-assay variation was highest in the petri dish assay. A positive correlation between IE binding avidity and the level of binding after antibody inhibition in the petri dish assay indicate that high avidity IE binding is more difficult to inhibit. The highest binding inhibition sensitivity was found in the 96-well and petri dish assays compared to the flow and perfusion assays where binding inhibition required higher antibody titers. The inhibitory capacity of antibodies is not easily translated between assays and the high sensitivity of the 96-well and petri dish assays stresses the need for comparing serial dilutions of serum. Furthermore, IE binding avidity must be in the same range when comparing data from different days. There was an overall concordance in the capacity of antibody-mediated inhibition, when comparing the in vitro assays with the perfusion assay, which more closely represents in vivo conditions. Importantly the ID1-ID2a protein in a liposomal formulation, currently in a phase I trial, effectively induced antibodies that inhibited IE adhesion in placental tissue. Copyright © 2016. Published by Elsevier Ltd.
Kemleu, Sylvie; Guelig, Dylan; Eboumbou Moukoko, Carole; Essangui, Estelle; Diesburg, Steven; Mouliom, Abas; Melingui, Bernard; Manga, Jeanne; Donkeu, Christiane; Epote, Annie; Texier, Gaëtan; LaBarre, Paul; Burton, Robert
2016-01-01
Highly sensitive and field deployable molecular diagnostic tools are critically needed for detecting submicroscopic, yet transmissible levels of malaria parasites prevalent in malaria endemic countries worldwide. A reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed and evaluated in comparison with thick blood smear microscopy, an antigen-based rapid diagnostic test (RDT), and an in-house RT-PCR targeting the same RT-LAMP transcript. The optimized assay detected Plasmodium falciparum infections in as little as 0.25ng of total parasite RNA, and exhibited a detection limit of 0.08 parasites/ μL when tested directly on infected whole blood lysates, or ~0.0008 parasites/ μL when using RNA extracts. Assay positivity was observed as early as eight minutes from initiation of the RT-LAMP and in most cases the reaction was complete before twenty minutes. Clinical evaluation of the assay on 132 suspected malaria cases resulted in a positivity rate of 90% for RT-LAMP using extracted RNA, and 85% when using whole blood lysates. The positivity rates were 70% for P. falciparum-specific RDT, 83% for RT-PCR, and 74% for thick blood smear microscopy (Mean parasite density = 36,986 parasites/ μL). Concordance rates between the developed RT-LAMP and comparator tests were greater than 75%, the lowest being with light microscopy (78%, McNemar’s test: P = 0.0002), and the highest was with RT-PCR (87%, McNemar’s test: P = 0.0523). Compared to reference RT-PCR, assay sensitivity was 90% for RT-LAMP on whole blood, and 96% for RT-LAMP using corresponding RNA extracts. Electricity-free heaters were further developed and evaluated in comparison with a battery-operated isothermal amplification machine for use with the developed test in resource-limited settings. Taken together, the data highlight the benefits of targeting high abundant RNA transcripts in molecular diagnosis, as well as the potential usefulness of the developed RT-LAMP-assay in malaria diagnosis in low to high parasite density settings. PMID:27824866
High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.
Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna
2013-01-01
Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.
Han, Jingjia; Qian, Ximei; Wu, Qingling; Jha, Rajneesh; Duan, Jinshuai; Yang, Zhou; Maher, Kevin O; Nie, Shuming; Xu, Chunhui
2016-10-01
Human pluripotent stem cells (hPSCs) are a promising cell source for regenerative medicine, but their derivatives need to be rigorously evaluated for residual stem cells to prevent teratoma formation. Here, we report the development of novel surface-enhanced Raman scattering (SERS)-based assays that can detect trace numbers of undifferentiated hPSCs in mixed cell populations in a highly specific, ultra-sensitive, and time-efficient manner. By targeting stem cell surface markers SSEA-5 and TRA-1-60 individually or simultaneously, these SERS assays were able to identify as few as 1 stem cell in 10(6) cells, a sensitivity (0.0001%) which was ∼2000 to 15,000-fold higher than that of flow cytometry assays. Using the SERS assay, we demonstrate that the aggregation of hPSC-based cardiomyocyte differentiation cultures into 3D spheres significantly reduced SSEA-5(+) and TRA-1-60(+) cells compared with parallel 2D cultures. Thus, SERS may provide a powerful new technology for quality control of hPSC-derived products for preclinical and clinical applications. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Larson, Jeffrey S.; Goodman, Laurie J.; Tan, Yuping; Defazio-Eli, Lisa; Paquet, Agnes C.; Cook, Jennifer W.; Rivera, Amber; Frankson, Kristi; Bose, Jolly; Chen, Lili; Cheung, Judy; Shi, Yining; Irwin, Sarah; Kiss, Linda D. B.; Huang, Weidong; Utter, Shannon; Sherwood, Thomas; Bates, Michael; Weidler, Jodi; Parry, Gordon; Winslow, John; Petropoulos, Christos J.; Whitcomb, Jeannette M.
2010-01-01
We report here the results of the analytical validation of assays that measure HER2 total protein (H2T) and HER2 homodimer (H2D) expression in Formalin Fixed Paraffin Embedded (FFPE) breast cancer tumors as well as cell line controls. The assays are based on the VeraTag technology platform and are commercially available through a central CAP-accredited clinical reference laboratory. The accuracy of H2T measurements spans a broad dynamic range (2-3 logs) as evaluated by comparison with cross-validating technologies. The measurement of H2T expression demonstrates a sensitivity that is approximately 7–10 times greater than conventional immunohistochemistry (IHC) (HercepTest). The HERmark assay is a quantitative assay that sensitively and reproducibly measures continuous H2T and H2D protein expression levels and therefore may have the potential to stratify patients more accurately with respect to response to HER2-targeted therapies than current methods which rely on semiquantitative protein measurements (IHC) or on indirect assessments of gene amplification (FISH). PMID:21151530
Larson, Jeffrey S; Goodman, Laurie J; Tan, Yuping; Defazio-Eli, Lisa; Paquet, Agnes C; Cook, Jennifer W; Rivera, Amber; Frankson, Kristi; Bose, Jolly; Chen, Lili; Cheung, Judy; Shi, Yining; Irwin, Sarah; Kiss, Linda D B; Huang, Weidong; Utter, Shannon; Sherwood, Thomas; Bates, Michael; Weidler, Jodi; Parry, Gordon; Winslow, John; Petropoulos, Christos J; Whitcomb, Jeannette M
2010-06-28
We report here the results of the analytical validation of assays that measure HER2 total protein (H2T) and HER2 homodimer (H2D) expression in Formalin Fixed Paraffin Embedded (FFPE) breast cancer tumors as well as cell line controls. The assays are based on the VeraTag technology platform and are commercially available through a central CAP-accredited clinical reference laboratory. The accuracy of H2T measurements spans a broad dynamic range (2-3 logs) as evaluated by comparison with cross-validating technologies. The measurement of H2T expression demonstrates a sensitivity that is approximately 7-10 times greater than conventional immunohistochemistry (IHC) (HercepTest). The HERmark assay is a quantitative assay that sensitively and reproducibly measures continuous H2T and H2D protein expression levels and therefore may have the potential to stratify patients more accurately with respect to response to HER2-targeted therapies than current methods which rely on semiquantitative protein measurements (IHC) or on indirect assessments of gene amplification (FISH).
Pearson, Brooke; Mills, Alexander; Tucker, Madeline; Gao, Siyue; McLandsborough, Lynne; He, Lili
2018-06-01
Bacterial foodborne illness continues to be a pressing issue in our food supply. Rapid detection methods are needed for perishable foods due to their short shelf lives and significant contribution to foodborne illness. Previously, a sensitive and reliable surface-enhanced Raman spectroscopy (SERS) sandwich assay based on 3-mercaptophenylboronic acid (3-MBPA) as a capturer and indicator molecule was developed for rapid bacteria detection. In this study, we explored the advantages and constraints of this assay over the conventional aerobic plate count (APC) method and further developed methods for detection in real environmental and food matrices. The SERS sandwich assay was able to detect environmental bacteria in pond water and on spinach leaves at higher levels than the APC method. In addition, the SERS assay appeared to have higher sensitivity to quantify bacteria in the stationary phase. On the other hand, the APC method was more sensitive to cell viability. Finally, a method to detect bacteria in a challenging high-sugar juice matrix was developed to enhance bacteria capture. This study advanced the SERS technique for real applications in environment and food matrices. Copyright © 2017 Elsevier Ltd. All rights reserved.
Díaz-Toscano, Miriam Lizette; Olivas-Flores, Eva Maria; Zavaleta-Muñiz, Soraya Amali; Gamez-Nava, Jorge Ivan; Cardona-Muñoz, Ernesto German; Ponce-Guarneros, Manuel; Castro-Contreras, Uriel; Nava, Arnulfo; Salazar-Paramo, Mario; Celis, Alfredo; Fajardo-Robledo, Nicte Selene; Corona-Sanchez, Esther Guadalupe; Gonzalez-Lopez, Laura
2014-01-01
Determination of anti-citrullinated peptide antibodies (ACPA) plays a relevant role in the diagnosis of rheumatoid arthritis (RA). To date, it is still unclear if the use of several tests for these autoantibodies in the same patient offers additional value as compared to performing only one test. Therefore, we evaluated the performance of using two assays for ACPA: second-generation anti-citrullinated cyclic peptides antibodies (anti-CCP2) and anti-mutated citrullinated vimentin (anti-MCV) antibodies for the diagnosis of RA. We compared three groups: RA (n = 142), chronic inflammatory disease (CIRD, n = 86), and clinically healthy subjects (CHS, n = 56) to evaluate sensitivity, specificity, predictive values, and likelihood ratios (LR) of these two assays for the presence of RA. A lower frequency of positivity for anti-CCP2 was found in RA (66.2%) as compared with anti-MCV (81.0%). When comparing RA versus other CIRD, sensitivity increased when both assays were performed. This strategy of testing both assays had high specificity and LR+. We conclude that adding the assay of anti-MCV antibodies to the determination of anti-CCP2 increases the sensitivity for detecting seropositive RA. Therefore, we propose the use of both assays in the initial screening of RA in longitudinal studies, including early onset of undifferentiated arthritis. PMID:25025037
Cheng, Keding; Sloan, Angela; Avery, Kristen M; Coulthart, Michael; Carpenter, Michael; Knox, J David
2014-01-01
Real-time quaking-induced conversion (RT-QuIC), a highly specific and sensitive assay able to detect low levels of the disease-inducing isoform of the prion protein (PrP(d)) in brain tissue biopsies and cerebral spinal fluid, has great potential to become a method for diagnosing prion disease ante mortem. In order to standardize the assay method for routine analysis, an understanding of how physical and chemical factors affect the stability of the recombinant prion protein (rPrP) substrate and the RT-QuIC assay's sensitivity, specificity, and reproducibility is required. In this study, using sporadic Creutzfeldt-Jakob Disease brain homogenate to seed the reactions and an in vitro-expressed recombinant prion protein, hamster rPrP, as the substrate, the following factors affecting the RT-QuIC assay were examined: salt and substrate concentrations, substrate storage, and pH. Results demonstrated that both the generation of the quality and quantities of rPrP substrate critical to the reaction, as well as the RT-QuIC reaction itself required strict adherence to specific physical and chemical conditions. Once optimized, the RT-QuIC assay was confirmed to be a very specific and sensitive assay method for sCJD detection. Findings in this study indicate that further optimization and standardization of RT-QuIC assay is required before it can be adopted as a routine diagnostic test.
Peter, Trevor F.; Barbet, Anthony F.; Alleman, Arthur R.; Simbi, Bigboy H.; Burridge, Michael J.; Mahan, Suman M.
2000-01-01
We have previously reported that the pCS20 PCR detection assay for Cowdria ruminantium, the causative agent of heartwater disease of ruminants, is more sensitive than xenodiagnosis and the pCS20 DNA probe for the detection of infection in the vector Amblyomma ticks. Here, we further assessed the reliability of the PCR assay and applied it to field ticks. The assay detected DNA of 37 isolates of C. ruminantium originating from sites throughout the distribution of heartwater and had a specificity of 98% when infected ticks were processed concurrently with uninfected ticks. The assay did not detect DNA of Ehrlichia chaffeensis, which is closely related to C. ruminantium. PCR sensitivity varied with tick infection intensity and was high (97 to 88%) with ticks bearing 107 to 104 organisms but dropped to 61 and 28%, respectively, with ticks bearing 103 and 102 organisms. The assay also detected C. ruminantium in collections of Amblyomma hebraeum and Amblyomma variegatum field ticks from 17 heartwater-endemic sites in four southern African countries. Attempts at tick transmission of infection to small ruminants failed with four of these collections. The pCS20 PCR assay is presently the most characterized and reliable test for C. ruminantium in ticks and thus is highly useful for field and laboratory epidemiological investigations of heartwater. PMID:10747140
Receptor-based screening assays for the detection of antibiotics residues - A review.
Ahmed, Saeed; Ning, Jianan; Cheng, Guyue; Ahmad, Ijaz; Li, Jun; Mingyue, Liu; Qu, Wei; Iqbal, Mujahid; Shabbir, M A B; Yuan, Zonghui
2017-05-01
Consumer and regulatory agencies have a high concern to antibiotic residues in food producing animals, so appropriate screening assays of fast, sensitive, low cost, and easy sample preparation for the identification of these residues are essential for the food-safety insurance. Great efforts in the development of a high-throughput antibiotic screening assay have been made in recent years. Concerning the screening of antibiotic residue, this review elaborate an overview on the availability, advancement and applicability of antibiotic receptor based screening assays for the safety assessment of antibiotics usage (i.e. radio receptor assay, enzyme labeling assays, colloidal gold receptor assay, enzyme colorimetry assay and biosensor assay). This manuscript also tries to shed a light on the selection, preparation and future perspective of receptor protein for antibiotic residue detection. These assays have been introduced for the screening of numerous food samples. Receptor based screening technology for antibiotic detection has high accuracy. It has been concluded that at the same time, it can detect a class of drugs for certain receptor, and realize the multi-residue detection. These assays offer fast, easy and precise detection of antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.
Draz, Mohamed Shehata; Lu, Xiaonan
2016-01-01
As a major foodborne pathogen, Salmonella enterica serotype Enteritidis is increasingly rising as a global health concern. Here, we developed an integrated assay that combines loop mediated isothermal amplification (LAMP) and surface enhanced Raman spectroscopy (SERS) for DNA detection of S. Enteritidis using specifically designed Raman active Au-nanoprobes. The target DNA was amplified by LAMP and then labeled with Au-nanoprobes comprised of gold nanoparticle-modified with specific cy5/DNA probes to allow the detection by SERS. The sensitivity of the developed LAMP-SERS detection assay (66 CFU/mL) was ~100-fold higher than the conventional polymerase chain reaction (PCR) method. Significantly, this technique allowed highly specific detection of the target DNA of S. Enteritidis and could differentiate it from the DNA of closely related bacterial species or non-specific contamination, making it more accurate and reliable than the standard LAMP technique. The applicability of detection of S. Enteritidis in milk samples using LAMP-SERS assay was validated as well. In sum, the developed LAMP-SERS assay is highly specific and sensitive, and has the potential to be applied for rapid detection of different foodborne pathogens and other microbial contaminants.
Fritsch, Michael K; Bridge, Julia A; Schuster, Amy E; Perlman, Elizabeth J; Argani, Pedram
2003-01-01
Pediatric small round cell tumors still pose tremendous diagnostic problems. In difficult cases, the ability to detect tumor-specific gene fusion transcripts for several of these neoplasms, including Ewing sarcoma/peripheral primitive neuroectodermal tumor (ES/PNET), synovial sarcoma (SS), alveolar rhabdomyosarcoma (ARMS), and desmoplastic small round cell tumor (DSRCT) using reverse transcriptase-polymerase chain reaction (RT-PCR), can be extremely helpful. Few studies to date, however, have systematically examined several different tumor types for the presence of multiple different fusion transcripts in order to determine the specificity and sensitivity of the RT-PCR method, and no study has addressed this issue for formalin-fixed material. The objectives of this study were to address the specificity, sensitivity, and practicality of such an assay applied strictly to formalin-fixed tissue blocks. Our results demonstrate that, for these tumors, the overall sensitivity for detecting each fusion transcript is similar to that reported in the literature for RT-PCR on fresh or formalin-fixed tissues. The specificity of the assay is very high, being essentially 100% for each primer pair when interpreting the results from visual inspection of agarose gels. However, when these same agarose gels were examined using Southern blotting, a small number of tumors also yielded reproducibly detectable weak signals for unexpected fusion products, in addition to a strong signal for the expected fusion product. Fluorescence in situ hybridization (FISH) studies in one such case indicated that a rearrangement that would account for the unexpected fusion was not present, while another case was equivocal. The overall specificity for each primer pair used in this assay ranged from 94 to 100%. Therefore, RT-PCR using formalin-fixed paraffin-embedded tissue sections can be used to detect chimeric transcripts as a reliable, highly sensitive, and highly specific diagnostic assay. However, we strongly suggest that the final interpretation of the results from this assay be viewed in light of the other features of the case, including clinical history, histology, and immunohistochemistry, by the diagnostic pathologist. Additional studies such as FISH may be useful in clarifying the nature of equivocal or unexpected results.
Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.
Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon
2016-01-01
Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6-14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7-97.9%) and a specificity of 99.8% (95% CI, 99.1-100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4-98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04). Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.
Skogman, B H; Lager, M; Henningsson, A J; Tjernberg, I
2017-11-01
For laboratory diagnostics of Lyme neuroborreliosis (LNB), the recomBead Borrelia antibody index (AI) assay has shown promising results in a mixed age population, but has not previously been evaluated with specific focus on paediatric patients. The aim of the study was to evaluate the recomBead Borrelia AI assay in cerebrospinal fluid (CSF) for the laboratory diagnosis of LNB in children. We also wanted to explore whether early markers, such as CXCL13 in CSF and/or total IgM index could be useful as complementary diagnostic tools. Children being evaluated for LNB in a Swedish Lyme endemic area were included in the study (n = 146). Serum and CSF were collected on admission. Patients with other specific diagnoses were controls (n = 15). The recomBead Borrelia AI assay and the recomBead CXCL13 assay (Mikrogen) were applied together with total IgM index. The overall sensitivity for recomBead Borrelia AI (IgM and IgG together) was 74% and the specificity was 97%. However, the highest sensitivity (91%) at an acceptable level of specificity (90%) was obtained by recomBead Borrelia AI together with CXCL13 and total IgM index, showing a positive predictive value of 84% and a negative predictive value of 95%. Thus, the recomBead Borrelia AI assay performs with moderate sensitivity and high specificity in paediatric LNB patients. The major advantage seems to be increased sensitivity in the possible LNB group compared to the IDEIA assay. The diagnostic sensitivity may be further increased by using a combination of early markers, such as CXCL13 in CSF and total IgM index.
Turner, Andrew; Sasse, Jurgen; Varadi, Aniko
2016-10-19
Inherited disorders of haemoglobin are the world's most common genetic diseases, resulting in significant morbidity and mortality. The large number of mutations associated with the haemoglobin beta gene (HBB) makes gene scanning by High Resolution Melting (HRM) PCR an attractive diagnostic approach. However, existing HRM-PCR assays are not able to detect all common point mutations and have only a very limited ability to detect larger gene rearrangements. The aim of the current study was to develop a HBB assay, which can be used as a screening test in highly heterogeneous populations, for detection of both point mutations and larger gene rearrangements. The assay is based on a combination of conventional HRM-PCR and a novel Gene Ratio Analysis Copy Enumeration (GRACE) PCR method. HRM-PCR was extensively optimised, which included the use of an unlabelled probe and incorporation of universal bases into primers to prevent interference from common non-pathological polymorphisms. GRACE-PCR was employed to determine HBB gene copy numbers relative to a reference gene using melt curve analysis to detect rearrangements in the HBB gene. The performance of the assay was evaluated by analysing 410 samples. A total of 44 distinct pathological genotypes were detected. In comparison with reference methods, the assay has a sensitivity of 100 % and a specificity of 98 %. We have developed an assay that detects both point mutations and larger rearrangements of the HBB gene. This assay is quick, sensitive, specific and cost effective making it suitable as an initial screening test that can be used for highly heterogeneous cohorts.
Gaydos, C A; Cartwright, C P; Colaninno, P; Welsch, J; Holden, J; Ho, S Y; Webb, E M; Anderson, C; Bertuzis, R; Zhang, L; Miller, T; Leckie, G; Abravaya, K; Robinson, J
2010-09-01
A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians.
Gaydos, C. A.; Cartwright, C. P.; Colaninno, P.; Welsch, J.; Holden, J.; Ho, S. Y.; Webb, E. M.; Anderson, C.; Bertuzis, R.; Zhang, L.; Miller, T.; Leckie, G.; Abravaya, K.; Robinson, J.
2010-01-01
A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians. PMID:20668135
Singh, Urvashi B.; Pandey, Pooja; Mehta, Girija; Bhatnagar, Anuj K.; Mohan, Anant; Goyal, Vinay; Ahuja, Vineet; Ramachandran, Ranjani; Sachdeva, Kuldeep S.; Samantaray, Jyotish C.
2016-01-01
Background Newer molecular diagnostics have brought paradigm shift in early diagnosis of tuberculosis [TB]. WHO recommended use of GeneXpert MTB/RIF [Xpert] for Extra-pulmonary [EP] TB; critics have since questioned its efficiency. Methods The present study was designed to assess the performance of GeneXpert in 761 extra-pulmonary and 384 pulmonary specimens from patients clinically suspected of TB and compare with Phenotypic, Genotypic and Composite reference standards [CRS]. Results Comparison of GeneXpert results to CRS, demonstrated sensitivity of 100% and 90.68%, specificity of 100% and 99.62% for pulmonary and extra-pulmonary samples. On comparison with culture, sensitivity for Rifampicin [Rif] resistance detection was 87.5% and 81.82% respectively, while specificity was 100% for both pulmonary and extra-pulmonary TB. On comparison to sequencing of rpoB gene [Rif resistance determining region, RRDR], sensitivity was respectively 93.33% and 90% while specificity was 100% in both pulmonary and extra-pulmonary TB. GeneXpert assay missed 533CCG mutation in one sputum and dual mutation [517 & 519] in one pus sample, detected by sequencing. Sequencing picked dual mutation [529, 530] in a sputum sample sensitive to Rif, demonstrating, not all RRDR mutations lead to resistance. Conclusions Current study reports observations in a patient care setting in a high burden region, from a large collection of pulmonary and extra-pulmonary samples and puts to rest questions regarding sensitivity, specificity, detection of infrequent mutations and mutations responsible for low-level Rif resistance by GeneXpert. Improvements in the assay could offer further improvement in sensitivity of detection in different patient samples; nevertheless it may be difficult to improve sensitivity of Rif resistance detection if only one gene is targeted. Assay specificity was high both for TB detection and Rif resistance detection. Despite a few misses, the assay offers major boost to early diagnosis of TB and MDR-TB, in difficult to diagnose pauci-bacillary TB. PMID:26894283
Sinibaldi, Alberto; Sampaoli, Camilla; Danz, Norbert; Munzert, Peter; Sonntag, Frank; Centola, Fabio; Occhicone, Agostino; Tremante, Elisa; Giacomini, Patrizio; Michelotti, Francesco
2017-08-17
We report on the use of one-dimensional photonic crystals to detect clinically relevant concentrations of the cancer biomarker ERBB2 in cell lysates. Overexpression of the ERBB2 protein is associated with aggressive breast cancer subtypes. To detect soluble ERBB2, we developed an optical set-up which operates in both label-free and fluorescence modes. The detection approach makes use of a sandwich assay, in which the one-dimensional photonic crystals sustaining Bloch surface waves are modified with monoclonal antibodies, in order to guarantee high specificity during the biological recognition. We present the results of exemplary protein G based label-free assays in complex biological matrices, reaching an estimated limit of detection of 0.5 ng/mL. On-chip and chip-to-chip variability of the results is addressed too, providing repeatability rates. Moreover, results on fluorescence operation demonstrate the capability to perform high sensitive cancer biomarker assays reaching a resolution of 0.6 ng/mL, without protein G assistance. The resolution obtained in both modes meets international guidelines and recommendations (15 ng/mL) for ERBB2 quantification assays, providing an alternative tool to phenotype and diagnose molecular cancer subtypes.
Tripp, K.M.; Verstegen, J.P.; Deutsch, C.J.; Bonde, R.K.; Rodriguez, M.; Morales, B.; Schmitt, D.L.; Harr, K.E.
2008-01-01
The objective was to validate a high-sensitivity chemiluminescent assay of serum progesterone concentrations for pregnancy diagnosis in manatees. Assay analytical sensitivity was 0.1 ng/mL, with mean intra- and inter-assay coefficients of variation of 9.7 and 9.2%, respectively, and accuracy had a mean adjusted R2 of 0.98. Methods comparison (relative to Siemen's Coat-A-Count RIA) demonstrated r = 0.98, Deming regression slope of 0.95, and an intercept of 0.01. Based on ROC analysis, a progesterone concentration ???0.4 ng/mL was indicative of pregnancy. Assay results were not significantly altered by two freeze-thaw cycles of samples. Characteristic progesterone concentrations during pregnancy were Months 1-4 (1.7-4.7 ng/mL), 5-8 (???1.0 ng/mL), and 10 and 11 (0.3-0.5 ng/mL), whereas two late-pregnant females with impending abortion had progesterone concentrations of 0.1 ng/mL. Among pregnant females, maximum progesterone concentrations occurred in autumn (3.9 ?? 1.8 ng/mL), and were greater during all seasons than concentrations in non-pregnant females (0.1-0.2 ng/mL). Progesterone concentrations were also significantly higher in pregnant females than in non-pregnant females and males. This highly sensitive, specific, and diagnostic assay will be valuable for monitoring pregnancy and abortion in manatees. ?? 2008 Elsevier Inc.
Competitive horseradish peroxidase-linked aptamer assay for sensitive detection of Aflatoxin B1.
Sun, Linlin; Zhao, Qiang
2018-03-01
Aflatoxin B1 (AFB1) is one of highly toxic mycotoxins and a known human carcinogen. The frequent contamination of AFB1 in food products and large health risk of AFB1 have raised global concerns. Sensitive detection of AFB1 is of vital importance and highly demanded. Herein, we reported a competitive horseradish peroxidase (HRP)-linked aptamer assay for AFB1, combining the advantages of aptamer for affinity binding and enzyme label for signal amplification. In this assay, free AFB1 in solution competed with a covalent conjugate of bovine serum albumin-AFB1 (BSA-AFB1) coated on the wells of microplate in binding to the HRP-labeled aptamer probe. HRP attached on BSA-AFB1 in the wells catalyzed the conversion of substrates into products, allowing the final detection of AFB1 through measurement of the generated products. When TMB (3,3',5,5'-tetramethylbenzidine dihydrochloride) was used as substrate, absorbance analysis of the product of enzyme reaction enabled the detection of AFB1 at 0.2nM. We further lowered the detection limit of AFB1 to 0.01nM through chemiluminescence analysis by using chemiluminescence substrate of HRP. This assay enabled the detection of AFB1 in complex sample matrix, such as diluted white wine and maize flour. This assay provides a simple, sensitive and rapid method for AFB1 determination. Copyright © 2017 Elsevier B.V. All rights reserved.
Kojima, Hiroyuki; Takeuchi, Shinji; Iida, Mitsuru; Nakayama, Shoji F; Shiozaki, Takuya
2018-03-01
In developing countries in Asia, such as China, Vietnam, and Thailand, there is a strong need for the development of relatively rapid and low-cost bioassays for the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food samples. These compounds are known to induce a variety of toxic and biological effects through their ligand-specific binding of the aryl hydrocarbon receptor (AhR). Indeed, several AhR-mediated reporter gene assays are widely used as prescreening tools for high-resolution gas chromatography/high-resolution mass spectrometry (HRGC-HRMS) analysis, which individually measures 17 PCDD/Fs and 12 DL-PCBs. In 2008, we have developed a new sensitive and rapid reporter gene assay using a genetically engineered stable cell line, designated DR-EcoScreen cells. The DR-EcoScreen assay using these cells has a number of great advantages of its sensitivity to 2,3,7,8-tetrachlorodibenzo-p-dioxin and its simple procedure, which shows little variance in the data (within CV 10 %) compared to other reporter gene assays. In this review, we summarize the application of the DR-EcoScreen assay to the determination of PCDD/Fs and DL-PCBs in ambient air samples, in fish and shellfish samples, and in flue gas samples from incinerators and provide potential usefulness of this bioassay for the determination of PCDD/Fs and DL-PCBs in various matrices.
Tripp, K M; Verstegen, J P; Deutsch, C J; Bonde, R K; Rodriguez, M; Morales, B; Schmitt, D L; Harr, K E
2008-10-15
The objective was to validate a high-sensitivity chemiluminescent assay of serum progesterone concentrations for pregnancy diagnosis in manatees. Assay analytical sensitivity was 0.1 ng/mL, with mean intra- and inter-assay coefficients of variation of 9.7 and 9.2%, respectively, and accuracy had a mean adjusted R(2) of 0.98. Methods comparison (relative to Siemen's Coat-A-Count RIA) demonstrated r=0.98, Deming regression slope of 0.95, and an intercept of 0.01. Based on ROC analysis, a progesterone concentration >or=0.4 ng/mL was indicative of pregnancy. Assay results were not significantly altered by two freeze-thaw cycles of samples. Characteristic progesterone concentrations during pregnancy were Months 1-4 (1.7-4.7 ng/mL), 5-8 ( approximately 1.0 ng/mL), and 10 and 11 (0.3-0.5 ng/mL), whereas two late-pregnant females with impending abortion had progesterone concentrations of 0.1 ng/mL. Among pregnant females, maximum progesterone concentrations occurred in autumn (3.9+/-1.8 ng/mL), and were greater during all seasons than concentrations in non-pregnant females (0.1-0.2 ng/mL). Progesterone concentrations were also significantly higher in pregnant females than in non-pregnant females and males. This highly sensitive, specific, and diagnostic assay will be valuable for monitoring pregnancy and abortion in manatees.
A biolayer interferometry-based assay for rapid and highly sensitive detection of biowarfare agents.
Mechaly, Adva; Cohen, Hila; Cohen, Ofer; Mazor, Ohad
2016-08-01
Biolayer interferometry (BLI) is an optical technique that uses fiber-optic biosensors for label-free real-time monitoring of protein-protein interactions. In this study, we coupled the advantages of the Octet Red BLI system (automation, fluidics-free, and on-line monitoring) with a signal enhancement step and developed a rapid and sensitive immunological-based method for detection of biowarfare agents. As a proof of concept, we chose to demonstrate the efficacy of this novel assay for the detection of agents representing two classes of biothreats, proteinaceous toxins, and bacterial pathogens: ricin, a lethal plant toxin, and the gram-negative bacterium Francisella tularensis, the causative agent of tularemia. The assay setup consisted of biotinylated antibodies immobilized to the biosensor coupled with alkaline phosphatase-labeled antibodies as the detection moiety to create nonsoluble substrate crystals that precipitate on the sensor surface, thereby inducing a significant wavelength interference. It was found that this BLI-based assay enables sensitive detection of these pathogens (detection limits of 10 pg/ml and 1 × 10(4) pfu/ml ricin and F. tularensis, respectively) within a very short time frame (17 min). Owing to its simplicity, this assay can be easily adapted to detect other analytes in general, and biowarfare agents in particular, in a rapid and sensitive manner. Copyright © 2016 Elsevier Inc. All rights reserved.
2015-01-01
To develop a more sensitive immunoassay for malachite green (MG) and leucomalachite green (LMG), we identified the immunocomplex binding phage-borne peptides for use in the noncompetitive phage anti-immunocomplex assay (PHAIA). An anti-LMG monoclonal antibody (mAb) was used to select immunocomplex binding peptides from a circular random eight-amino-acid phage-displayed library. After three rounds of panning-elution, five peptides that bound the LMG–mAb immunocomplex were obtained. One of the phage-borne peptide clones that resulted in an assay with the highest sensitivity was chosen for further research. The concentration of LMG producing 50% of the saturated signal and the limit of detection of the assay were 7.02 and 0.55 ng/mL, respectively, with a linear range of 1.35 to 21.56 ng/mL. The PHAIA based on the same antibody was 16 times more sensitive compared to the competitive immunoassay. PHAIA was used to analyze LMG, MG, and two mixtures of spiked fish samples, with validation by high-performance liquid chromatography (HPLC) with fluorescence detector. Results showed a good correlation (R2LMG = 0.9841; R2MG = 0.993; R2Mixture = 0.9903) between the data of PHAIA and HPLC, thus the assay was an efficient method for monitoring food safety. PMID:25077381
Toxicogenomic identification of biomarkers of acute respiratory exposure sensitizing agents
Allergy induction requires multiple exposures to an agent. Therefore the development of high-throughput or in vitro assays for effective screening of potential sensitizers will require the identification of biomarkers. The goal of this preliminary study was to identify potential ...
Toxicogenomic identification of biomarkers of acute respiratory expsoure to sensitizing agents
Allergy induction requires multiple exposures to an agent. Therefore the development of high-throughput or in vitro assays for effective screening of potential sensitizers will require the identification of biomarkers. The goal of this preliminary study was to identify potential ...
*Biomarkers of acute respiratory allergen exposure: Screening for sensitization potential
Effective hazard screening will require the development of high-throughput or in vitro assays for the identification of potential sensitizers. The goal of this preliminary study was to identify potential biomarkers that differentiate the response to allergens vs non-allergens fol...
Galel, Susan A; Simon, Toby L; Williamson, Phillip C; AuBuchon, James P; Waxman, Dan A; Erickson, Yasuko; Bertuzis, Rasa; Duncan, John R; Malhotra, Khushbeer; Vaks, Jeffrey; Huynh, Nancy; Pate, Lisa Lee
2018-03-01
Use of nucleic acid testing (NAT) in donor infectious disease screening improves transfusion safety. Advances in NAT technology include improvements in assay sensitivity and system automation, and real-time viral target discrimination in multiplex assays. This article describes the sensitivity and specificity of cobas MPX, a multiplex assay for detection of human immunodeficiency virus (HIV)-1 Group M, HIV-2 and HIV-1 Group O RNA, HCV RNA, and HBV DNA, for use on the cobas 6800/8800 Systems. The specificity of cobas MPX was evaluated in samples from donors of blood and source plasma in the United States. Analytic sensitivity was determined with reference standards. Infectious window periods (WPs) before NAT detectability were calculated for current donor screening assays. The specificity of cobas MPX was 99.946% (99.883%-99.980%) in 11,203 blood donor samples tested individually (IDT), 100% (99.994%-100%) in 63,012 donor samples tested in pools of 6, and 99.994% (99.988%-99.998%) in 108,306 source plasma donations tested in pools of 96. Seven HCV NAT-yield donations and one seronegative occult HBV infection were detected. Ninety-five percent and 50% detection limits in plasma (IU/mL) were 25.7 and 3.8 for HIV-1M, 7.0 and 1.3 for HCV, and 1.4 and 0.3 for HBV. The HBV WP was 1 to 4 days shorter than other donor screening assays by IDT. cobas MPX demonstrated high specificity in blood and source plasma donations tested individually and in pools. High sensitivity, in particular for HBV, shortens the WP and may enhance detection of occult HBV. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
Hofmann-Thiel, Sabine; Molodtsov, Nikolay; Antonenka, Uladzimir; Hoffmann, Harald
2016-12-01
The Abbott RealTime MTB (RT MTB) assay is a new automated nucleic acid amplification test for the detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. In combination with the RealTime MTB INH/RIF (RT MTB INH/RIF) resistance assay, which can be applied to RT MTB-positive specimens as an add-on assay, the tests also indicate the genetic markers of resistance to isoniazid (INH) and rifampin (RIF). We aimed to evaluate the diagnostic sensitivity and specificity of RT MTB using different types of respiratory and extrapulmonary specimens and to compare performance characteristics directly with those of the FluoroType MTB assay. The resistance results obtained by RT MTB INH/RIF were compared to those from the GenoType MTBDRplus and from phenotypic drug susceptibility testing. A total of 715 clinical specimens were analyzed. Compared to culture, the overall sensitivity of RT MTB was 92.1%; the sensitivity rates for smear-positive and smear-negative samples were 100% and 76.2%, respectively. The sensitivities of smear-negative specimens were almost identical for respiratory (76.3%) and extrapulmonary (76%) specimens. Specificity rates were 100% and 95.8% for culture-negative specimens and those that grew nontuberculous mycobacteria, respectively. RT MTB INH/RIF was applied to 233 RT MTB-positive samples and identified resistance markers in 7.7% of samples. Agreement with phenotypic and genotypic drug susceptibility testing was 99.5%. In conclusion, RT MTB and RT MTB INH/RIF allow for the rapid and accurate diagnosis of tuberculosis (TB) in different types of specimens and reliably indicate resistance markers. The strengths of this system are the comparably high sensitivity with paucibacillary specimens, its ability to detect INH and RIF resistance, and its high-throughput capacities. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Shields, E; Seiden-Long, I; Massie, S; Passante, S; Leguillette, R
2016-06-13
Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.
Jiang, Danni; Cao, Biyun; Wang, Meiyu; Yang, Hong; Zhao, Kang; Li, Jianguo; Li, Mingxin; Sun, Lulu; Deng, Anping
2017-02-01
All β-agonists are banned as feed additives for growth promotion in animals due to toxic effects on humans after consuming the β-agonist contaminated meats. Phenylethanolamine A (PA) is a newly emerged β-agonist. Thus there is a need to develop highly sensitive and specific analytical methods for the detection of PA in food samples. In this study, the monoclonal antibody (mAb) against PA was produced by hybridoma technology and used for the development of enzyme-linked immunosorbent assay (ELISA). The IC 50 values and limits of detection (LODs) of the ELISA using homogeneous combination of coating antigen/antibody for PA were 0.16 ng mL -1 and 0.011 ng mL -1 , respectively. The cross-reactive (CR) values of the assay with 14 structurally related β-agonists were lower than 0.59%. Swine liver and meat samples were spiked with PA at different content and analysed by ELISA. Acceptable recovery rates of 91.40-105.51% and intra-assay coefficients of variation of 1.56-9.92% (n = 3) were obtained. The ELISA for seven spiked samples was confirmed by LC-MS/MS with a high correlation coefficient of 0.9881. The proposed mAb-based ELISA was highly sensitive and specific for PA and could be used as a quantitative/screening method for PA analysis in food samples. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Yang, Yang; Qin, Xiaodong; Sun, Yingjun; Cong, Guozheng; Li, Yanmin; Zhang, Zhidong
2017-01-01
Porcine circovirus virus type II (PCV2) is the etiology of postweaning multisystemic wasting syndrome (PMWS), porcine dermatitis, nephropathy syndrome (PDNS), and necrotizing pneumonia. Rapid diagnosis tool for detection of PCV2 plays an important role in the disease control and eradication program. Recombinase polymerase amplification (RPA) assays using a real-time fluorescent detection (PCV2 real-time RPA assay) and RPA combined with lateral flow dipstick (PCV2 RPA LFD assay) were developed targeting the PCV2 ORF2 gene. The results showed that the sensitivity of the PCV2 real-time RPA assay was 10 2 copies per reaction within 20 min at 37°C and the PCV2 RPA LFD assay had a detection limit of 10 2 copies per reaction in less than 20 min at 37°C. Both assays were highly specific for PCV2, with no cross-reactions with porcine circovirus virus type 1, foot-and-mouth disease virus, pseudorabies virus, porcine parvovirus, porcine reproductive and respiratory syndrome virus, and classical swine fever virus. Therefore, the RPA assays provide a novel alternative for simple, sensitive, and specific identification of PCV2.
Yang, Yang; Qin, Xiaodong; Sun, Yingjun; Cong, Guozheng; Li, Yanmin
2017-01-01
Porcine circovirus virus type II (PCV2) is the etiology of postweaning multisystemic wasting syndrome (PMWS), porcine dermatitis, nephropathy syndrome (PDNS), and necrotizing pneumonia. Rapid diagnosis tool for detection of PCV2 plays an important role in the disease control and eradication program. Recombinase polymerase amplification (RPA) assays using a real-time fluorescent detection (PCV2 real-time RPA assay) and RPA combined with lateral flow dipstick (PCV2 RPA LFD assay) were developed targeting the PCV2 ORF2 gene. The results showed that the sensitivity of the PCV2 real-time RPA assay was 102 copies per reaction within 20 min at 37°C and the PCV2 RPA LFD assay had a detection limit of 102 copies per reaction in less than 20 min at 37°C. Both assays were highly specific for PCV2, with no cross-reactions with porcine circovirus virus type 1, foot-and-mouth disease virus, pseudorabies virus, porcine parvovirus, porcine reproductive and respiratory syndrome virus, and classical swine fever virus. Therefore, the RPA assays provide a novel alternative for simple, sensitive, and specific identification of PCV2. PMID:28424790
McKim, James M.; Hartung, Thomas; Kleensang, Andre; Sá-Rocha, Vanessa
2016-01-01
Supervised learning methods promise to improve integrated testing strategies (ITS), but must be adjusted to handle high dimensionality and dose–response data. ITS approaches are currently fueled by the increasing mechanistic understanding of adverse outcome pathways (AOP) and the development of tests reflecting these mechanisms. Simple approaches to combine skin sensitization data sets, such as weight of evidence, fail due to problems in information redundancy and high dimension-ality. The problem is further amplified when potency information (dose/response) of hazards would be estimated. Skin sensitization currently serves as the foster child for AOP and ITS development, as legislative pressures combined with a very good mechanistic understanding of contact dermatitis have led to test development and relatively large high-quality data sets. We curated such a data set and combined a recursive variable selection algorithm to evaluate the information available through in silico, in chemico and in vitro assays. Chemical similarity alone could not cluster chemicals’ potency, and in vitro models consistently ranked high in recursive feature elimination. This allows reducing the number of tests included in an ITS. Next, we analyzed with a hidden Markov model that takes advantage of an intrinsic inter-relationship among the local lymph node assay classes, i.e. the monotonous connection between local lymph node assay and dose. The dose-informed random forest/hidden Markov model was superior to the dose-naive random forest model on all data sets. Although balanced accuracy improvement may seem small, this obscures the actual improvement in misclassifications as the dose-informed hidden Markov model strongly reduced "false-negatives" (i.e. extreme sensitizers as non-sensitizer) on all data sets. PMID:26046447
Luechtefeld, Thomas; Maertens, Alexandra; McKim, James M; Hartung, Thomas; Kleensang, Andre; Sá-Rocha, Vanessa
2015-11-01
Supervised learning methods promise to improve integrated testing strategies (ITS), but must be adjusted to handle high dimensionality and dose-response data. ITS approaches are currently fueled by the increasing mechanistic understanding of adverse outcome pathways (AOP) and the development of tests reflecting these mechanisms. Simple approaches to combine skin sensitization data sets, such as weight of evidence, fail due to problems in information redundancy and high dimensionality. The problem is further amplified when potency information (dose/response) of hazards would be estimated. Skin sensitization currently serves as the foster child for AOP and ITS development, as legislative pressures combined with a very good mechanistic understanding of contact dermatitis have led to test development and relatively large high-quality data sets. We curated such a data set and combined a recursive variable selection algorithm to evaluate the information available through in silico, in chemico and in vitro assays. Chemical similarity alone could not cluster chemicals' potency, and in vitro models consistently ranked high in recursive feature elimination. This allows reducing the number of tests included in an ITS. Next, we analyzed with a hidden Markov model that takes advantage of an intrinsic inter-relationship among the local lymph node assay classes, i.e. the monotonous connection between local lymph node assay and dose. The dose-informed random forest/hidden Markov model was superior to the dose-naive random forest model on all data sets. Although balanced accuracy improvement may seem small, this obscures the actual improvement in misclassifications as the dose-informed hidden Markov model strongly reduced " false-negatives" (i.e. extreme sensitizers as non-sensitizer) on all data sets. Copyright © 2015 John Wiley & Sons, Ltd.
Springer, Jan; Schloßnagel, Hannes; Heinz, Werner; Doedt, Thomas; Soeller, Rainer; Einsele, Hermann
2012-01-01
Diagnosis of invasive aspergillosis (IA) is still a major problem in routine clinical practice. Early diagnosis is essential for a good patient prognosis. PCR is a highly sensitive method for the detection of nucleic acids and could play an important role in improving the diagnosis of fungal infections. Therefore, a novel DNA extraction method, ultraclean production (UCP), was developed allowing purification of both cellular and cell-free circulating fungal DNA. In this prospective study we evaluated the commercially available UCP extraction system and compared it to an in-house system. Sixty-three patients at high risk for IA were screened twice weekly, and DNA extracted by both methods was cross-analyzed, in triplicate, by two different real-time PCR assays. The negative predictive values were high for all methods (94.3 to 100%), qualifying them as screening methods, but the sensitivity and diagnostic odds ratios were higher using the UCP extraction method. Sensitivity ranged from 33.3 to 66.7% using the in-house extracts to 100% using the UCP extraction method. Most of the unclassified patients showed no positive PCR results; however, single-positive PCR replicates were observed in some cases. These can bear clinical relevance but should be interpreted with additional clinical and laboratory data. The PCR assays from the UCP extracts showed greater reproducibility than the in-house method for probable IA patients. The standardized UCP extraction method yielded superior results, with regard to sensitivity and reproducibility, than the in-house method. This was independent of the PCR assay used to detect fungal DNA in the sample extracts. PMID:22593600
Lee, Jia-Ying Joey; Miller, James Alastair; Basu, Sreetama; Kee, Ting-Zhen Vanessa; Loo, Lit-Hsin
2018-06-01
Human lungs are susceptible to the toxicity induced by soluble xenobiotics. However, the direct cellular effects of many pulmonotoxic chemicals are not always clear, and thus, a general in vitro assay for testing pulmonotoxicity applicable to a wide variety of chemicals is not currently available. Here, we report a study that uses high-throughput imaging and artificial intelligence to build an in vitro pulmonotoxicity assay by automatically comparing and selecting human lung-cell lines and their associated quantitative phenotypic features most predictive of in vivo pulmonotoxicity. This approach is called "High-throughput In vitro Phenotypic Profiling for Toxicity Prediction" (HIPPTox). We found that the resulting assay based on two phenotypic features of a human bronchial epithelial cell line, BEAS-2B, can accurately classify 33 reference chemicals with human pulmonotoxicity information (88.8% balance accuracy, 84.6% sensitivity, and 93.0% specificity). In comparison, the predictivity of a standard cell-viability assay on the same set of chemicals is much lower (77.1% balanced accuracy, 84.6% sensitivity, and 69.5% specificity). We also used the assay to evaluate 17 additional test chemicals with unknown/unclear human pulmonotoxicity, and experimentally confirmed that many of the pulmonotoxic reference and predicted-positive test chemicals induce DNA strand breaks and/or activation of the DNA-damage response (DDR) pathway. Therefore, HIPPTox helps us to uncover these common modes-of-action of pulmonotoxic chemicals. HIPPTox may also be applied to other cell types or models, and accelerate the development of predictive in vitro assays for other cell-type- or organ-specific toxicities.
Li, Gen; Li, Feng; Zhao, Hui-Min; Wen, Han-Li; Li, Hai-Cong; Li, Chun-Ling; Ji, Ping; Xu, Peng; Wu, Kang; Hu, Zhi-Dong; Lu, Shui-Hua; Lowrie, Douglas B; Lv, Jian-Xin; Fan, Xiao-Yong
2017-01-01
Blood-based interferon-gamma (IFN-γ) release assays (IGRAs) have been proven to be useful in the diagnosis of Mycobacterium tuberculosis ( Mtb ) infection. However, IGRAs have not been recommended for clinical practice in most low-income settings due to cost-intensive limitations and shortage of clinical data available. The established T-SPOT. TB assay containing Mtb -specific antigens ESAT-6 and CFP10 are widely used for immunodiagonsis of Mtb infection, but the high cost is one of the restricting factors against its clinical application in the developing countries. More recently, a cost-saving IGRA assay, TS-SPOT, was approved in China. This new assay contains an additional antigen Rv3615c. Rv3615c contains broadly recognized CD4 + and CD8 + epitopes, and T-cell responses to Rv3615c are as specific for Mtb infection as the responses to ESAT-6 and CFP10 in both Mtb -infected humans and M. bovis -infected cattle. Therefore, we assessed the likely effect of inclusion of Rv3615c as stimulus besides ESAT-6 and CFP10 in an IGRA assay and evaluated the performance of TS-SPOT for diagnosis of Mtb infection and active TB compared with T-SPOT. TB . We tested 155 active TB patients, 90 non-TB lung disease patients, and 55 healthy individuals. The results presented an improved positive rate for diagnosis of active TB and Mtb infection, that could be attributable to inclusion of Rv3615c in the mixture of stimulatory antigens. The diagnostic efficiency of TS-SPOT assay for active TB was as follows: sensitivity 80.00%, specificity 83.45%, positive predictive value (PPV) 83.78%, negative predictive value (NPV) 83.45%, positive likelihood ratio (LR+) 4.83, and negative likelihood ratio (LR-) 0.24. The results were similar to those of T-SPOT. TB , with an excellent agreement (κ = 0.91, 95% CI: 0.85-0.95) being observed between these two assays. The sensitivities of the TS-SPOT assay varied for patients with different forms of active TB, with the highest sensitivity for patients with culture-positive pulmonary TB (92.16%) and the lowest for those with tuberculosis meningitis (50.00%). Taken together, the current evidence indicates that this new TS-SPOT assay is a useful adjunct to the current tests for rapid diagnosis of active TB and Mtb infection in low-income and high-incidence settings due to its characteristics of cost-effectiveness and high-quality.
Elkins, Kelly M; Perez, Anjelica C U; Quinn, Alicia A
2017-05-01
The international prevalence of "legal high" drugs necessitates the development of a method for their detection and identification. Herein, we describe the development and validation of a tetraplex multiplex real-time polymerase chain reaction (PCR) assay used to simultaneously identify morning glory, jimson weed, Hawaiian woodrose, and marijuana detected by high-resolution melt using LCGreen Plus ® . The PCR assay was evaluated based on the following: (i) specificity and selectivity-primers were tested on DNA extracted from 30 species and simulated forensic samples, (ii) sensitivity-serial dilutions of the target DNA were prepared, and (iii) reproducibility and reliability-sample replicates were tested and remelted on different days. The assay is ideal for cases in which inexpensive assays are needed to quickly detect and identify trace biological material present on drug paraphernalia that is too compromised for botanical microscopic identification and for which analysts are unfamiliar with the morphology of the emerging "legal high" species. © 2016 American Academy of Forensic Sciences.
A new sensitive PCR assay for one-step detection of 12 IDH1/2 mutations in glioma.
Catteau, Aurélie; Girardi, Hélène; Monville, Florence; Poggionovo, Cécile; Carpentier, Sabrina; Frayssinet, Véronique; Voss, Jesse; Jenkins, Robert; Boisselier, Blandine; Mokhtari, Karima; Sanson, Marc; Peyro-Saint-Paul, Hélène; Giannini, Caterina
2014-06-02
Mutations in isocitrate dehydrogenase genes IDH1 or IDH2 are frequent in glioma, and IDH mutation status is a strong diagnostic and prognostic marker. Current IDH mutation screening is performed with an immunohistochemistry (IHC) assay specific for IDH1 R132H, the most common mutation. Sequencing is recommended as a second-step test for IHC-negative or -equivocal cases. We developed and validated a new real-time quantitative polymerase chain reaction (PCR) assay for single-step detection of IDH1 R132H and 11 rare IDH1/2 mutations in formalin-fixed paraffin-embedded (FFPE) glioma samples. Performance of the IDH1/2 PCR assay was compared to IHC and Sanger sequencing. The IDH1/2 PCR assay combines PCR clamping for detection of 7 IDH1 and 5 IDH2 mutations, and Amplification Refractory Mutation System technology for specific identification of the 3 most common mutations (IDH1 R132H, IDH1 R132C, IDH2 R172K). Analytical sensitivity of the PCR assay for mutation detection was <5% for 11/12 mutations (mean: 3.3%), and sensitivity for mutation identification was very high (0.8% for IDH1 R132H; 1.2% for IDH1 R132C; 0.6% for IDH2 R172K). Assay performance was further validated on 171 clinical glioma FFPE samples; of these, 147 samples met the selection criteria and 146 DNA samples were successfully extracted. IDH1/2 status was successfully obtained in 91% of cases. All but one positive IDH1 R132H-IHC cases were concordantly detected by PCR and 3 were not detected by sequencing. Among the IHC-negative cases (n = 72), PCR detected 12 additional rare mutations (10 IDH1, 2 IDH2). All mutations detected by sequencing (n = 67) were concordantly detected by PCR and 5/66 sequencing-negative cases were PCR-positive (overall concordance: 96%). Analysis of synthetic samples representative of the 11 rare IDH1/2 mutations detected by the assay produced 100% correct results. The new IDH1/2 PCR assay has a high technical success rate and is more sensitive than Sanger sequencing. Positive concordance was 98% with IHC for IDH1 R132H detection and 100% with sequencing. The PCR assay can reliably be performed on FFPE samples and has a faster turnaround time than current IDH mutation detection algorithms. The assay should facilitate implementation of a comprehensive IDH1/2 testing protocol in routine clinical practice.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-01-01
Objectives We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Design Systematic review and meta-analysis. Data sources PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. Study eligibility criteria This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. Primary and secondary outcome measures We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. Results We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). Conclusions hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion. PMID:24556243
Prigenzi, Karla Calaça Kabbach; Heinke, Thaís; Salim, Rafael Calil; Focchi, Gustavo Rubino de Azevedo
2018-01-01
Our objective was to verify the sensitivity and specificity of dual immunocytochemistry staining for p16 and Ki-67 in liquid-based samples (the "dual" assay) for cervical lesion screening, compared to biopsy findings and human papillomavirus (HPV) DNA molecular detection. Sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values for the "dual immunocytochemistry assay" were calculated and compared to histopathological results and to high-risk HPV DNA detection in adult women or teenagers submitted to cervical cancer screening. A total of 151 women were included. The majority (96.2%) of those with negative dual assay results had lower biopsy grades (p < 0.001). Women with cytology results suggestive of cervical cancer had positive dual immunocytochemistry assay results more frequently (p < 0.001), and these positive results were also significantly associated with biopsy findings (p < 0.001) and with high-risk genotype HPV infection (p = 0.007). Specificity and PPV for the dual assay were 0.972 (0.855-0.999) and 0.800 (0.284-0.995), respectively, and 1.000 (0.590-1.000) and 1.000 (0.631-1.000) for HPV detection. The dual immunocytochemistry assay had high specificity and PPV. It reveals a persistent HPV infection, avoiding the need for new tissue collections for biopsies or hybrid capture. © 2018 S. Karger AG, Basel.
Garritsen, H S; Probst-Kepper, M; Legath, N; Eberl, W; Samaniego, S; Woudenberg, J; Schuitemaker, J H N; Kroll, H; Gurney, D A; Moore, G W; Zehnder, J L
2014-04-01
Heparin-induced thrombocytopenia (HIT) is a life-threatening condition, in which the anticoagulant heparin, platelet factor 4 (PF4), and platelet-activating antibodies form complexes with prothrombotic properties. Laboratory tests to support clinical diagnosis are subdivided into functional, platelet activation assays, which lack standardization, or immunological assays, which have moderate specificity toward HIT. In this study, clinical performance of HITAlert, a novel in vitro diagnostic (IVD) registered platelet activation assay, was tested in a large cohort of HIT-suspected patients and compared with immunological assays. From 346 HIT-suspected patients (single center), clinical data including 4T pretest probability results, citrated platelet-poor plasmas, and sera were collected, allowing direct comparison of clinical observations with HITAlert results. HITAlert performance was compared with PF4 IgG ELISA (246 patients, three centers) and PF4 PaGIA (298 patients, single center). HITAlert showed high sensitivity (88.2%) and specificity (99.1%) when compared with clinical diagnosis. Agreement of HITAlert with PF4 ELISA- and PF4 PaGIA-positive patients is low (52.7 and 23.2%, respectively), while agreement with PF4 IgG ELISA- and PF4 PaGIA-negative patients is very high (98.1 and 99.1%, respectively). HITAlert performance is excellent when compared with clinical HIT diagnosis, making it a suitable assay for rapid testing of platelet activation due to anticoagulant therapy. © 2013 John Wiley & Sons Ltd.
Han, Bomie; Higgs, Richard E
2008-09-01
High-throughput HPLC-mass spectrometry (HPLC-MS) is routinely used to profile biological samples for potential protein markers of disease, drug efficacy and toxicity. The discovery technology has advanced to the point where translating hypotheses from proteomic profiling studies into clinical use is the bottleneck to realizing the full potential of these approaches. The first step in this translation is the development and analytical validation of a higher throughput assay with improved sensitivity and selectivity relative to typical profiling assays. Multiple reaction monitoring (MRM) assays are an attractive approach for this stage of biomarker development given their improved sensitivity and specificity, the speed at which the assays can be developed and the quantitative nature of the assay. While the profiling assays are performed with ion trap mass spectrometers, MRM assays are traditionally developed in quadrupole-based mass spectrometers. Development of MRM assays from the same instrument used in the profiling analysis enables a seamless and rapid transition from hypothesis generation to validation. This report provides guidelines for rapidly developing an MRM assay using the same mass spectrometry platform used for profiling experiments (typically ion traps) and reviews methodological and analytical validation considerations. The analytical validation guidelines presented are drawn from existing practices on immunological assays and are applicable to any mass spectrometry platform technology.
An improved Abbott ARCHITECT assay for the detection of hepatitis B virus surface antigen (HBsAg).
Lou, Sheng C; Pearce, Sandra K; Lukaszewska, Teresa X; Taylor, Russell E; Williams, Gregg T; Leary, Thomas P
2011-05-01
The sensitive and accurate detection of hepatitis B virus surface antigen (HBsAg) is critical to the identification of infection and the prevention of transfusion transmitted disease. Improvement in HBsAg assay sensitivity is essential to reduce the window to detect an acute HBV infection. Additionally, the sensitive detection of HBsAg mutants that continue to evolve due to vaccine escape, immune selection and an error prone reverse transcriptase is a necessity. A fully automated HBsAg prototype assay on the Abbott ARCHITECT instrument was developed to improve sensitivity and mutant detection. This magnetic microparticle-based assay utilizes anti-HBsAg monoclonal antibodies to capture antigen present in serum or plasma. Captured antigen is then detected using anti-HBsAg antibody conjugated with the chemiluminescent compound, acridinium. The sensitivity of the ARCHITECT HBsAg prototype assay was improved as compared to the current ARCHITECT, PRISM, and competitor HBsAg assays. The enhancement in assay sensitivity was demonstrated by the use of commercially available HBV seroconversion panels. The prototype assay detected more panel members (185 of 383) vs. the current ARCHITECT (171), PRISM (181), or competitor HBsAg assays (73/140 vs. 62/140, respectively). The ARCHITECT prototype assay also efficiently detected all mutants evaluated. Finally, the sensitivity improvement did not compromise the specificity of the assay (99.94%). An improved Abbott ARCHITECT HBsAg prototype assay with enhanced detection of HBsAg and HBsAg mutants, as well as equivalent specificity was developed for the detection, diagnosis, and management of HBV infection. Copyright © 2011 Elsevier B.V. All rights reserved.
Cáceres, Diego H; Zuluaga, Alejandra; Tabares, Ángela M; Chiller, Tom; González, Ángel; Gómez, Beatriz L
2017-12-21
A Lateral Flow Assay to detect cryptococcal antigen (CrAg® LFA) in serum and cerebrospinal fluid for the rapid diagnosis of cryptococcosis was evaluated. A retrospective validation was performed. Sensitivity and specificity of the CrAg® LFA was 100%. High concordance (kappa index=1.0) between Cryptococcal Antigen Latex Agglutination System (CALAS®) and CrAg® LFA was observed. CrAg® LFA showed higher analytical sensitivity for detecting low concentrations of cryptococcal antigen.
Cáceres, Diego H.; Zuluaga, Alejandra; Tabares, Ángela M.; Chiller, Tom; González, Ángel; Gómez, Beatriz L.
2017-01-01
ABSTRACT A Lateral Flow Assay to detect cryptococcal antigen (CrAg® LFA) in serum and cerebrospinal fluid for the rapid diagnosis of cryptococcosis was evaluated. A retrospective validation was performed. Sensitivity and specificity of the CrAg® LFA was 100%. High concordance (kappa index=1.0) between Cryptococcal Antigen Latex Agglutination System (CALAS®) and CrAg® LFA was observed. CrAg® LFA showed higher analytical sensitivity for detecting low concentrations of cryptococcal antigen. PMID:29267584
Natsch, Andreas; Emter, Roger; Ellis, Graham
2009-01-01
Tests for skin sensitization are required prior to the market launch of new cosmetic ingredients. Significant efforts are made to replace the current animal tests. It is widely recognized that this cannot be accomplished with a single in vitro test, but that rather the integration of results from different in vitro and in silico assays will be needed for the prediction of the skin sensitization potential of chemicals. This has been proposed as a theoretical scheme so far, but no attempts have been made to use experimental data to prove the validity of this concept. Here we thus try for the first time to fill this widely cited concept with data. To this aim, we integrate and report both novel and literature data on 116 chemicals of known skin sensitization potential on the following parameters: (1) peptide reactivity as a surrogate for protein binding, (2) induction of antioxidant/electrophile responsive element dependent luciferase activity as a cell-based assay; (3) Tissue Metabolism Simulator skin sensitization model in silico prediction; and (4) calculated octanol-water partition coefficient. The results of the in vitro assays were scaled into five classes from 0 to 4 to give an in vitro score and compared to the local lymph node assay (LLNA) data, which were also scaled from 0 to 4 (nonsensitizer/weak/moderate/strong/extreme). Different ways of evaluating these data have been assessed to rate the hazard of chemicals (Cooper statistics) and to also scale their potency. With the optimized model an overall accuracy for predicting sensitizers of 87.9% was obtained. There is a linear correlation between the LLNA score and the in vitro score. However, the correlation needs further improvement as there is still a relatively high variation in the in vitro score between chemicals belonging to the same sensitization potency class.
Schalasta, Gunnar; Speicher, Andrea; Börner, Anna; Enders, Martin
2016-04-01
Quantitating the level of hepatitis C virus (HCV) RNA is the standard of care for monitoring HCV-infected patients during treatment. The performances of commercially available assays differ for precision, limit of detection, and limit of quantitation (LOQ). Here, we compare the performance of the Hologic Aptima HCV Quant Dx assay (Aptima) to that of the Roche Cobas TaqMan HCV test, version 2.0, using the High Pure system (HPS/CTM), considered a reference assay since it has been used in trials defining clinical decision points in patient care. The assays' performance characteristics were assessed using HCV RNA reference panels and plasma/serum from chronically HCV-infected patients. The agreement between the assays for the 3 reference panels was good, with a difference in quantitation values of <0.5 log. High concordance was demonstrated between the assays for 245 clinical samples (kappa = 0.80; 95% confidence interval [CI], 0.720 to 0.881); however, Aptima detected and/or quantitated 20 samples that HPS/CTM did not detect, while Aptima did not detect 1 sample that was quantitated by HPS/CTM. For the 165 samples quantitated by both assays, the values were highly correlated (R= 0.98;P< 0.0001). The linearity of quantitation from concentrations of 1.4 to 6 log was excellent for both assays for all HCV genotypes (GT) tested (GT 1a, 1b, 2b, and 3a) (R(2)> 0.99). The assays had similar levels of total and intra-assay variability across all genotypes at concentrations from 1,000 to 25 IU/ml. Aptima had a greater analytical sensitivity, quantitating more than 50% of replicates at 25-IU/ml target. Aptima showed performance characteristics comparable to those of HPS/CTM and increased sensitivity, making it suitable for use as a clinical diagnostic tool on the fully automated Panther platform. Copyright © 2016 Schalasta et al.
Wu, Ping; Tu, Yunqiu; Qian, Yingdan; Zhang, Hui; Cai, Chenxin
2014-01-28
We report a new strategy for evaluating multiple miRNA expressions in cancer cells based on DNA strand-displacement-induced fluorescence enhancement. This assay has the ability to discriminate the target from even single-base mismatched sequences or other miRNAs.
USDA-ARS?s Scientific Manuscript database
Comparative sequence analysis of six independent chicken and turkey parvovirus nonstructural (NS) genes revealed specific genomic regions with 100% nucleotide sequence identity. A PCR assay with primers targeting these conserved genome sequences proved to be highly specific and sensitive to detect p...
In vitro detection and quantification of botulinum neurotoxin type E activity in avian blood
Piazza, T.M.; Blehert, D.S.; Dunning, F.M.; Berlowski-Zier, B. M.; Zeytin, F.N.; Samuel, M.D.; Tucker, W.C.
2011-01-01
Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by F??rster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity. ?? 2011, American Society for Microbiology.
In vitro detection and quantification of botulinum neurotoxin type E activity in avian blood
Piazza, Timothy M.; Blehert, David S.; Dunning, F. Mark; Berlowski-Zier, Brenda M.; Zeytin, Fusun N.; Samuel, Michael D.; Tucker, Ward C.
2011-01-01
Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by Förster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity.
Janse, Ingmar; Hamidjaja, Raditijo A; Hendriks, Amber C A; van Rotterdam, Bart J
2013-02-14
Burkholderia mallei and B. pseudomallei are two closely related species of highly virulent bacteria that can be difficult to detect. Pathogenic Burkholderia are endemic in many regions worldwide and cases of infection, sometimes brought by travelers from unsuspected regions, also occur elsewhere. Rapid, sensitive methods for identification of B. mallei and B. pseudomallei are urgently needed in the interests of patient treatment and epidemiological surveillance. Signature sequences for sensitive, specific detection of pathogenic Burkholderia based on published genomes were identified and a qPCR assay was designed and validated. A single-reaction quadruplex qPCR assay for the detection of pathogenic Burkholderia, which includes a marker for internal control of DNA extraction and amplification, was developed. The assay permits differentiation of B. mallei and B. pseudomallei strains, and probit analysis showed a very low detection limit. Use of a multicopy signature sequence permits detection of less than 1 genome equivalent per reaction. The new assay permits rapid detection of pathogenic Burkholderia and combines enhanced sensitivity, species differentiation, and inclusion of an internal control for both DNA extraction and PCR amplification.
In Vitro Detection and Quantification of Botulinum Neurotoxin Type E Activity in Avian Blood▿
Piazza, Timothy M.; Blehert, David S.; Dunning, F. Mark; Berlowski-Zier, Brenda M.; Zeytin, Füsûn N.; Samuel, Michael D.; Tucker, Ward C.
2011-01-01
Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by Förster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity. PMID:21908624
Schnepf, Nathalie; Scieux, Catherine; Resche-Riggon, Matthieu; Feghoul, Linda; Xhaard, Alienor; Gallien, Sébastien; Molina, Jean-Michel; Socié, Gérard; Viglietti, Denis; Simon, François; Mazeron, Marie-Christine
2013-01-01
Fully standardized reproducible and sensitive quantification assays for cytomegalovirus (CMV) are needed to better define thresholds for antiviral therapy initiation and interruption. We evaluated the newly released Abbott RealTime CMV assay for CMV quantification in whole blood (WB) that includes automated extraction and amplification (m2000 RealTime system). Sensitivity, accuracy, linearity, and intra- and interassay variability were validated in a WB matrix using Quality Control for Molecular Diagnostics (QCMD) panels and the WHO international standard (IS). The intra- and interassay coefficients of variation were 1.37% and 2.09% at 5 log10 copies/ml and 2.41% and 3.80% at 3 log10 copies/ml, respectively. According to expected values for the QCMD and Abbott RealTime CMV methods, the lower limits of quantification were 104 and <50 copies/ml, respectively. The conversion factor between international units and copies (2.18), determined from serial dilutions of the WHO IS in WB, was significantly different from the factor provided by the manufacturer (1.56) (P = 0.001). Results from 302 clinical samples were compared with those from the Qiagen artus CMV assay on the same m2000 RealTime system. The two assays provided highly concordant results (concordance correlation coefficient, 0.92), but the Abbott RealTime CMV assay detected and quantified, respectively, 20.6% and 47.8% more samples than the Qiagen/artus CMV assay. The sensitivity and reproducibility of the results, along with the automation, fulfilled the quality requirements for implementation of the Abbott RealTime CMV assay in clinical settings. Our results highlight the need for careful validation of conversion factors provided by the manufacturers for the WHO IS in WB to allow future comparison of results obtained with different assays. PMID:23616450
Playford, E. Geoffrey; Walker, John
2002-01-01
Rapid diagnostic tests (RDTs) are less reliant on expert microscopy and have the potential to reduce errors in malaria diagnosis but have not been extensively evaluated in nonimmune persons or in countries where infection is not endemic. We evaluated the ICT P.f/P.v (ICT-Amrad, Sydney, Australia) and OptiMal (Flow Inc., Portland, Oreg.) assays prospectively for the diagnosis of malaria in 158 specimens from 144 febrile returned travellers in Australia by using expert microscopy and PCR as reference standards. Malaria was diagnosed in 93 specimens from 87 patients by expert microscopy, with 3 additional specimens from recently treated patients testing positive for Plasmodium falciparum by PCR. For the diagnosis of asexual-stage P. falciparum malaria, the sensitivity and specificity of the ICT P.f/P.v assay were 97 and 90%, respectively, and those of the OptiMal assay were 85 and 96%, respectively. The ICT P.f/P.v assay missed one infection with a density of 45 parasites/μl, whereas the OptiMal assay missed infections up to 2,500/μl; below 1,000/μl, its sensitivity was only 43%. For the diagnosis of P. vivax malaria, the sensitivity and specificity of the ICT P.f/P.v assay were 44 and 100%, respectively, and those of the OptiMal assay were 80 and 97%, respectively. Both assays missed infections with parasite densities over 5,000/μl: up to 10,000/μl with the former and 5,300/μl with the latter. Despite the high sensitivity of the ICT P.f/P.v assay for P. falciparum malaria, caution is warranted before RDTs are widely adopted for the diagnosis of malaria in nonimmune patients or in countries where malaria is not endemic. PMID:12409392
High-sensitivity immunochromatographic assay for fumonisin B1 based on indirect antibody labeling.
Urusov, Alexandr E; Petrakova, Alina V; Gubaydullina, Milyausha K; Zherdev, Anatoly V; Eremin, Sergei A; Kong, Dezhao; Liu, Liqiang; Xu, Chuanlai; Dzantiev, Boris B
2017-05-01
To develop a high-sensitivity immunochromatographic test for fumonisin B1 in plant extracts. Unlike conventional immunochromatographic tests, this assay is performed in two stages: competitive reaction with free specific antibodies and identifying immune complexes by their interaction with the anti-species antibody-conjugated gold nanoparticles. The use of a new geometry for the test strip membranes and a novel reagent application method ensures the proper order of these stages without additional manipulations. The contact of the ready-to-use test strip with the liquid sample suffices in initiating all stages of the assay and obtaining test results. The developed test was used on corn extracts; its instrumental limit of fumonisin B1 detection was 0.6 ng ml -1 at 15 min of assay duration. The proposed approach is flexible and can be used for a wide range of low molecular compounds. The use of anti-species antibody-conjugated gold nanoparticles in immunochromatography significantly facilitates the development of test systems by eliminating the need to synthesize and characterize the conjugates with specific antibodies for each new compound to be detected.
Trier, Nicole Hartwig; Holm, Bettina Eide; Heiden, Julie; Slot, Ole; Locht, Henning; Lindegaard, Hanne; Svendsen, Anders; Nielsen, Christoffer Tandrup; Jacobsen, Søren; Theander, Elke; Houen, Gunnar
2018-02-27
Rheumatoid arthritis (RA) is a chronic systemic autoimmune disease. Anti-citrullinated protein antibodies (ACPA) are crucial for the serological diagnosis of RA, where Epstein-Barr virus (EBV) has been suggested to be an environmental agent in triggering the onset of the disease. This study aimed to analyse antibody reactivity to citrullinated EBV nuclear antigen-2 (EBNA-2) peptides from three different EBV strains (B95-8, GD1 and AG876) using streptavidin capture enzyme-linked immunosorbent assay. One peptide, only found in a single strain (AG876), obtained a sensitivity and specificity of 77% and 95%, respectively and showed high sequence similarity to the filaggrin peptide originally used for ACPA detection. Comparison of antibody reactivity to commercial assays found that the citrullinated peptide was as effective in detecting ACPA as highly sensitive and specific commercial assays. The data presented demonstrate that the citrullinated EBNA-2 peptide indeed is recognised specifically by RA sera and that the single peptide is able to compete with assays containing multiple peptides. Furthermore, it could be hypothesized that RA may be caused by (a) specific strain(s) of EBV.
Haynes, Lia M; Miao, Congrong; Harcourt, Jennifer L; Montgomery, Joel M; Le, Mai Quynh; Dryga, Sergey A; Kamrud, Kurt I; Rivers, Bryan; Babcock, Gregory J; Oliver, Jennifer Betts; Comer, James A; Reynolds, Mary; Uyeki, Timothy M; Bausch, Daniel; Ksiazek, Thomas; Thomas, William; Alterson, Harold; Smith, Jonathan; Ambrosino, Donna M; Anderson, Larry J
2007-03-01
Recombinant severe acute respiratory syndrome (SARS) nucleocapsid and spike protein-based immunoglobulin G immunoassays were developed and evaluated. Our assays demonstrated high sensitivity and specificity to the SARS coronavirus in sera collected from patients as late as 2 years postonset of symptoms. These assays will be useful not only for routine SARS coronavirus diagnostics but also for epidemiological and antibody kinetic studies.
Haynes, Lia M.; Miao, Congrong; Harcourt, Jennifer L.; Montgomery, Joel M.; Le, Mai Quynh; Dryga, Sergey A.; Kamrud, Kurt I.; Rivers, Bryan; Babcock, Gregory J.; Oliver, Jennifer Betts; Comer, James A.; Reynolds, Mary; Uyeki, Timothy M.; Bausch, Daniel; Ksiazek, Thomas; Thomas, William; Alterson, Harold; Smith, Jonathan; Ambrosino, Donna M.; Anderson, Larry J.
2007-01-01
Recombinant severe acute respiratory syndrome (SARS) nucleocapsid and spike protein-based immunoglobulin G immunoassays were developed and evaluated. Our assays demonstrated high sensitivity and specificity to the SARS coronavirus in sera collected from patients as late as 2 years postonset of symptoms. These assays will be useful not only for routine SARS coronavirus diagnostics but also for epidemiological and antibody kinetic studies. PMID:17229882
Collinson, Paul O; Heung, Yen Ming; Gaze, David; Boa, Frances; Senior, Roxy; Christenson, Robert; Apple, Fred S
2012-01-01
We sought to determine the effect of patient selection on the 99th reference percentile of 2 sensitive and 1 high-sensitivity (hs) cardiac troponin assays in a well-defined reference population. Individuals>45 years old were randomly selected from 7 representative local community practices. Detailed information regarding the participants was collected via questionnaires. The healthy reference population was defined as individuals who had no history of vascular disease, hypertension, or heavy alcohol intake; were not receiving cardiac medication; and had blood pressure<140/90 mmHg, fasting blood glucose<110 mg/dL (approximately 6 mmol/L), estimated creatinine clearance>60 mL·min(-1)·(1.73 m2)(-1), and normal cardiac function according to results of echocardiography. Samples were stored at -70 °C until analysis for cardiac troponin I (cTnI) and cardiac troponin T (cTnT) and N-terminal pro-B-type natriuretic peptide. Application of progressively more stringent population selection strategies to the initial baseline population of 545 participants until the only individuals who remained were completely healthy according to the study criteria reduced the number of outliers seen and led to a progressive decrease in the 99th-percentile value obtained for the Roche hs-cTnT assay and the sensitive Beckman cTnI assay but not for the sensitive Siemens Ultra cTnI assay. Furthermore, a sex difference found in the baseline population for the hs-cTnT (P=0.0018) and Beckman cTnI assays (P<0.0001) progressively decreased with more stringent population selection criteria. The reference population selection strategy significantly influenced the 99th percentile reference values determined for troponin assays and the observed sex differences in troponin concentrations.
de Lemos, James A; Drazner, Mark H; Omland, Torbjorn; Ayers, Colby R; Khera, Amit; Rohatgi, Anand; Hashim, Ibrahim; Berry, Jarett D; Das, Sandeep R; Morrow, David A; McGuire, Darren K
2010-12-08
Detectable levels of cardiac troponin T (cTnT) are strongly associated with structural heart disease and increased risk of death and adverse cardiovascular events; however, cTnT is rarely detectable in the general population using standard assays. To determine the prevalence and determinants of detectable cTnT in the population using a new highly sensitive assay and to assess whether cTnT levels measured with the new assay associate with pathological cardiac phenotypes and subsequent mortality. Cardiac troponin T levels were measured using both the standard and the highly sensitive assays in 3546 individuals aged 30 to 65 years enrolled between 2000 and 2002 in the Dallas Heart Study, a multiethnic, population-based cohort study. Mortality follow-up was complete through 2007. Participants were placed into 5 categories based on cTnT levels. Magnetic resonance imaging measurements of cardiac structure and function and mortality through a median of 6.4 (interquartile range, 6.0-6.8) years of follow-up. In Dallas County, the prevalence of detectable cTnT (≥0.003 ng/mL) was 25.0% (95% confidence interval [CI], 22.7%-27.4%) with the highly sensitive assay vs 0.7% (95% CI, 0.3%-1.1%) with the standard assay. Prevalence was 37.1% (95% CI, 33.3%-41.0%) in men vs 12.9% (95% CI, 10.6%-15.2%) in women and 14.0% (95% CI, 11.2%-16.9%) in participants younger than 40 years vs 57.6% (95% CI, 47.0%-68.2%) in those 60 years and older. Prevalence of left ventricular hypertrophy increased from 7.5% (95% CI, 6.4%-8.8%) in the lowest cTnT category (<0.003 ng/mL) to 48.1% (95% CI, 36.7%-59.6%) in the highest (≥0.014 ng/mL) (P < .001); prevalence of left ventricular systolic dysfunction and chronic kidney disease also increased across categories (P < .001 for each). During a median follow-up of 6.4 years, there were 151 total deaths, including 62 cardiovascular disease deaths. All-cause mortality increased from 1.9% (95% CI, 1.5%-2.6%) to 28.4% (95% CI, 21.0%-37.8%) across higher cTnT categories (P < .001). After adjustment for traditional risk factors, C-reactive protein level, chronic kidney disease, and N-terminal pro-brain-type natriuretic peptide level, cTnT category remained independently associated with all-cause mortality (adjusted hazard ratio, 2.8 [95% CI, 1.4-5.2] in the highest category). Adding cTnT categories to the fully adjusted mortality model modestly improved model fit (P = .02) and the integrated discrimination index (0.010 [95% CI, 0.002-0.018]; P = .01). In this population-based cohort, cTnT detected with a highly sensitive assay was associated with structural heart disease and subsequent risk for all-cause mortality.
Roberts, David W; Patlewicz, Grace
2018-01-01
There is an expectation that to meet regulatory requirements, and avoid or minimize animal testing, integrated approaches to testing and assessment will be needed that rely on assays representing key events (KEs) in the skin sensitization adverse outcome pathway. Three non-animal assays have been formally validated and regulatory adopted: the direct peptide reactivity assay (DPRA), the KeratinoSens™ assay and the human cell line activation test (h-CLAT). There have been many efforts to develop integrated approaches to testing and assessment with the "two out of three" approach attracting much attention. Here a set of 271 chemicals with mouse, human and non-animal sensitization test data was evaluated to compare the predictive performances of the three individual non-animal assays, their binary combinations and the "two out of three" approach in predicting skin sensitization potential. The most predictive approach was to use both the DPRA and h-CLAT as follows: (1) perform DPRA - if positive, classify as sensitizing, and (2) if negative, perform h-CLAT - a positive outcome denotes a sensitizer, a negative, a non-sensitizer. With this approach, 85% (local lymph node assay) and 93% (human) of non-sensitizer predictions were correct, whereas the "two out of three" approach had 69% (local lymph node assay) and 79% (human) of non-sensitizer predictions correct. The findings are consistent with the argument, supported by published quantitative mechanistic models that only the first KE needs to be modeled. All three assays model this KE to an extent. The value of using more than one assay depends on how the different assays compensate for each other's technical limitations. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Cheng, Luisa W; Henderson, Thomas D; Lam, Tina I; Stanker, Larry H
2015-11-27
Botulinum neurotoxins (BoNT) are some of nature's most potent toxins. Due to potential food contamination, and bioterrorism concerns, the development of detection reagents, therapeutics and countermeasures are of urgent interest. Recently, we have developed a sensitive electrochemiluminescent (ECL) immunoassay for BoNT/B, using monoclonal antibodies (mAbs) MCS6-27 and anti-BoNT/B rabbit polyclonal antibodies as the capture and detector. The ECL assay detected as little as 1 pg/mL BoNT/B in the buffer matrix, surpassing the detection sensitivities of the gold standard mouse bioassays. The ECL assay also allowed detection of BoNT/B in sera matrices of up to 100% sera with negligible matrix effects. This highly-sensitive assay allowed the determination of the biological half-lives of BoNT/B holotoxin in vivo. We further tested the toxin neutralization potential of our monoclonal antibodies using the mouse systemic and oral intoxication models. A combination of mAbs protected mice in both pre- and post-exposure models to lethal doses of BoNT/B. MAbs were capable of increasing survival of animals when administered even 10 h post-intoxication in an oral model, suggesting a likely time for BoNT/B complexes to reach the blood stream. More sensitive detection assays and treatments against BoNT intoxication will greatly enhance efforts to combat botulism.
Cheng, Luisa W.; Henderson, Thomas D.; Lam, Tina I.; Stanker, Larry H.
2015-01-01
Botulinum neurotoxins (BoNT) are some of nature’s most potent toxins. Due to potential food contamination, and bioterrorism concerns, the development of detection reagents, therapeutics and countermeasures are of urgent interest. Recently, we have developed a sensitive electrochemiluminescent (ECL) immunoassay for BoNT/B, using monoclonal antibodies (mAbs) MCS6-27 and anti-BoNT/B rabbit polyclonal antibodies as the capture and detector. The ECL assay detected as little as 1 pg/mL BoNT/B in the buffer matrix, surpassing the detection sensitivities of the gold standard mouse bioassays. The ECL assay also allowed detection of BoNT/B in sera matrices of up to 100% sera with negligible matrix effects. This highly-sensitive assay allowed the determination of the biological half-lives of BoNT/B holotoxin in vivo. We further tested the toxin neutralization potential of our monoclonal antibodies using the mouse systemic and oral intoxication models. A combination of mAbs protected mice in both pre- and post-exposure models to lethal doses of BoNT/B. MAbs were capable of increasing survival of animals when administered even 10 h post-intoxication in an oral model, suggesting a likely time for BoNT/B complexes to reach the blood stream. More sensitive detection assays and treatments against BoNT intoxication will greatly enhance efforts to combat botulism. PMID:26633496
Johansson, Hanna; Bjelkenkrantz, Kaj; Darlin, Lotten; Dilllner, Joakim; Forslund, Ola
2015-01-01
Objective Continuous expression of E6- and E7-oncogenes of high-risk human papillomavirus (HPV) types is necessary for the development and maintenance of the dysplastic phenotype. The aim of the study was to determine the sensitivity and specificity of the APTIMA HPV mRNA assay (Hologic) in predicting future development of high-grade cervical intraepithelial neoplasia (CIN) among high-risk HPV-DNA-positive women with atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous epithelial lesion (LSIL) cytology. Methods Archived SurePath cervical samples of women ≥ 35 years of age with high-risk HPV DNA-positive ASCUS (n = 211) or LSIL, (n = 131) were tested for the presence of high-risk HPV E6/E7 mRNA using the APTIMA HPV assay, and the women were monitored for development of histopathologically verified CIN2+. Results Twenty-nine percent (61/211) of the women in the ASCUS group, and 34.3% (45/131) in the LSIL group developed CIN2+ within 4.5 years of follow-up. The prevalence of HPV mRNA was 90.0% (95% CI 85.9-94.0) among women with ASCUS and 95.4% (95% CI 91.8-99.0) among women with LSIL. The presence of HPV E6/E7 mRNA was associated with future development of CIN2+ among women with ASCUS and LSIL (p=0.02). The mRNA assay demonstrated high sensitivity in predicting future CIN2+ and CIN3 for index ASCUS (96.7%; 95% CI 87.6-99.4 and 100%; 95% CI 82.2-100, respectively) and LSIL (97.8%, 95% CI 86.8-99.9 and 100%, 95% CI 79.9-100, respectively). The corresponding specificity was low, 12.7% (95% CI 7.9-19.3) and 5.8% (95% CI 2.2-13.6), for future CIN2+, respectively. The negative predictive value of the HPV mRNA assay for detecting future CIN3 was 100%, since no mRNA-negative woman developed CIN3 (0/27) as compared to 13.6% (43/315) of the mRNA-positive women (p = 0.03). Conclusion The APTIMA mRNA assay demonstrated high sensitivity but low specificity in predicting future CIN2+ among women with minor cytological abnormalities. The assay had high negative predictive value for future CIN3, indicating that HPV-mRNA-negative women are at low risk of progression to high grade CIN. PMID:25893988
Universal reverse-transcriptase real-time PCR for infectious hematopoietic necrosis virus (IHNV)
Purcell, Maureen K.; Thompson, Rachel L.; Garver, Kyle A.; Hawley, Laura M.; Batts, William N.; Sprague, Laura; Sampson, Corie; Winton, James R.
2013-01-01
Infectious hematopoietic necrosis virus (IHNV) is an acute pathogen of salmonid fishes in North America, Europe and Asia and is reportable to the World Organization for Animal Health (OIE). Phylogenetic analysis has identified 5 major virus genogroups of IHNV worldwide, designated U, M, L, E and J; multiple subtypes also exist within those genogroups. Here, we report the development and validation of a universal IHNV reverse-transcriptase real-time PCR (RT-rPCR) assay targeting the IHNV nucleocapsid (N) gene. Properties of diagnostic sensitivity (DSe) and specificity (DSp) were defined using laboratory-challenged steelhead trout Oncorhynchus mykiss, and the new assay was compared to the OIE-accepted conventional PCR test and virus isolation in cell culture. The IHNV N gene RT-rPCR had 100% DSp and DSe and a higher estimated diagnostic odds ratio (DOR) than virus culture or conventional PCR. The RT-rPCR assay was highly repeatable within a laboratory and highly reproducible between laboratories. Field testing of the assay was conducted on a random sample of juvenile steelhead collected from a hatchery raceway experiencing an IHN epizootic. The RT-rPCR detected a greater number of positive samples than cell culture and there was 40% agreement between the 2 tests. Overall, the RT-rPCR assay was highly sensitive, specific, repeatable and reproducible and is suitable for use in a diagnostic setting.
A multiplex calibrated real-time PCR assay for quantitation of DNA of EBV-1 and 2.
Gatto, Francesca; Cassina, Giulia; Broccolo, Francesco; Morreale, Giuseppe; Lanino, Edoardo; Di Marco, Eddi; Vardas, Efthiya; Bernasconi, Daniela; Buttò, Stefano; Principi, Nicola; Esposito, Susanna; Scarlatti, Gabriella; Lusso, Paolo; Malnati, Mauro S
2011-12-01
Accurate and highly sensitive tests for the diagnosis of active Epstein-Barr virus (EBV) infection are essential for the clinical management of individuals infected with EBV. A calibrated quantitative real-time PCR assay for the measurement of EBV DNA of both EBV-1 and 2 subtypes was developed, combining the detection of the EBV DNA and a synthetic DNA calibrator in a multiplex PCR format. The assay displays a wide dynamic range and a high degree of accuracy even in the presence of 1μg of human genomic DNA. This assay measures with the same efficiency EBV DNA from strains prevalent in different geographic areas. The clinical sensitivity and specificity of the system were evaluated by testing 181 peripheral blood mononuclear cell (PBMCs) and plasma specimens obtained from 21 patients subjected to bone marrow transplantation, 70 HIV-seropositive subjects and 23 healthy controls. Patients affected by EBV-associated post-transplant lymphoprolipherative disorders had the highest frequency of EBV detection and the highest viral load. Persons infected with HIV had higher levels of EBV DNA load in PBMCs and a higher frequency of EBV plasma viremia compared to healthy controls. In conclusion, this new assay provides a reliable high-throughput method for the quantitation of EBV DNA in clinical samples. Copyright © 2011 Elsevier B.V. All rights reserved.
He, Jintang; Schepmoes, Athena A.; Shi, Tujin; ...
2015-01-01
Background: The established methods for detecting prostate cancer (CaP) are based on tests using PSA (blood), PCA3 (urine), and AMACR (tissue) as biomarkers in patient samples. The demonstration of ERG oncoprotein overexpression due to gene fusion in CaP has thus provided ERG as an additional biomarker. Based on this, we hypothesized that ERG protein quantification methods can be of use in the diagnosis of prostate cancer. Methods: Therefore, an antibody-free assay for ERG3 protein detection was developed based on PRISM (high-pressure high-resolution separations with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometry. We utilized TMPRSS2-ERG positive VCaP and TMPRSS2-ERGmore » negative LNCaP cells to simulate three different sample types (cells, tissue, and post-DRE urine sediment). Results: Recombinant ERG3 protein spiked into LNCaP cell lysates could be detected at levels as low as 20 pg by PRISM-SRM analysis. The sensitivity of the PRISM-SRM assay was around approximately 10,000 VCaP cells in a mixed cell population model of VCaP and LNCaP cells. Interestingly, ERG protein could be detected in as few as 600 VCaP cells spiked into female urine. The sensitivity of the in-house enzyme-linked immunosorbent assay (ELISA) was similar to the PRISM-SRM assay, with detection of 30 pg of purified recombinant ERG3 protein and 10,000 VCaP cells. On the other hand, qRT-PCR exhibited a higher sensitivity, as TMPRSS2-ERG transcripts were detected in as few as 100 VCaP cells, in comparison to NanoString methodologies which detected ERG from 10,000 cells. Conclusions: Based on this data, we propose that the detection of both ERG transcriptional products with RNA-based assays, as well as protein products of ERG using PRISM-SRM assays, may be of clinical value in developing diagnostics and prognostics assays for prostate cancer given their sensitivity, specificity, and reproducibility.« less
Directed evolution of PDZ variants to generate high-affinity detection reagents.
Ferrer, Marc; Maiolo, Jim; Kratz, Patricia; Jackowski, Jessica L; Murphy, Dennis J; Delagrave, Simon; Inglese, James
2005-04-01
High-throughput protease assays are used to identify new protease inhibitors which have the potential to become valuable therapeutic products. Antibodies are of great utility as affinity reagents to detect proteolysis products in protease assays, but isolating and producing such antibodies is unreliable, slow and costly. It has been shown previously that PDZ domains can also be used to detect proteolysis products in high-throughput homogeneous assays but their limited natural repertoire restricts their use to only a few peptides. Here we show that directed evolution is an efficient way to create new PDZ domains for detection of protease activity. We report the first use of phage display to alter the specificity of a PDZ domain, yielding three variants with up to 25-fold increased affinity for a peptide cleavage product of HIV protease. Three distinct roles are assigned to the amino acid substitutions found in the selected variants of the NHERF PDZ domain: specific 'beta1-beta3' interaction with ligand residue -1, interactions with ligand residues -4 to -7 and improvement in phage display efficiency. The variants, having affinities as high as 620 nM, display improvements in assay sensitivity of over 5-fold while requiring smaller amounts of reagents. The approach demonstrated here leads the way to highly sensitive reagents for drug discovery that can be isolated more reliably and produced less expensively.
A quantitative TaqMan PCR assay for the detection of Ureaplasma diversum.
Marques, Lucas M; Amorim, Aline T; Martins, Hellen Braga; Rezende, Izadora Souza; Barbosa, Maysa Santos; Lobão, Tassia Neves; Campos, Guilherme B; Timenetsky, Jorge
2013-12-27
Ureaplasma diversum in veterinary studies is an undesirable microbe, which may cause infection in bulls and may result in seminal vesiculitis, balanopostitis, and alterations in spermatozoids, whereas in cows, it may cause placentitis, fetal alveolitis, abortion, and birth of weak calves. U. diversum is released through organic secretions, especially semen, preputial and vaginal mucus, conjunctival secretion, and milk. The aim of the present study was to develop a TaqMan probe, highly sensitive and specific quantitative PCR (qPCR) assay for the detection and quantification of U. diversum from genital swabs of bovines. Primers and probes specific to U. diversum 16S rRNA gene were designed. The specificity, detection limit, intra- and inter-assay variability of qPCR to detect this ureaplasma was compared with the results of the conventional PCR assay (cPCR). Swabs of vaginal mucus from 169 cows were tested. The qPCR assay detected as few as 10 copies of U. diversum and was 100-fold more sensitive than the cPCR. No cross-reactivity with other Mollicutes or eubacteria was observed. U. diversum was detected in 79 swabs (46.42%) by qPCR, while using cPCR it was detected in 42 (25%) samples. The difference in cPCR and qPCR ureaplasma detection between healthy and sick animals was not statistically significant. But the U. diversum load in samples from animals with genital disorders was higher than in healthy animals. The qPCR assay developed herein is highly sensitive and specific for the detection and quantification of U. diversum in vaginal bovine samples. Copyright © 2013. Published by Elsevier B.V.
Jarolim, Petr; Patel, Purvish P; Conrad, Michael J; Chang, Lei; Melenovsky, Vojtech; Wilson, David H
2015-10-01
The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an investigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals. © 2015 American Association for Clinical Chemistry.
Skaik, Younis; Battermann, Anja; Hiller, Oliver; Meyer, Oliver; Figueiredo, Constanca; Salama, Abdulgabar; Blasczyk, Rainer
2013-05-31
Timely and accurate testing for human platelet antigen 1a (HPA-1a) alloantibodies is vital for clinical diagnosis of neonatal alloimmune thrombocytopenia (NAIT). Current antigen-specific assays used for the detection of HPA-1 alloantibodies are technically very complex and cumbersome for most diagnostic laboratories. Hence, we designed and applied recombinant soluble (rs) β3 integrins displaying HPA-1a or HPA-1b epitopes for the development of a single-antigen magnetic bead assay (SAMBA). Soluble HPA-1a and HPA-1b were produced recombinantly in human embryonic kidney 293 (HEK293) cells and differentially tagged. The recombinant soluble proteins were then immobilized onto paramagnetic beads and used for analysis of HPA-1 alloantibodies by enzyme-linked immunosorbent assay (ELISA). HPA-1a serum samples (n=7) from NAIT patients, inert sera and sera containing non-HPA-1a antibodies were used to evaluate the sensitivity and specificity of the SAMBA. Fusion of V5-His or GS-SBP-His tags to the rsβ3 integrins resulted in high-yield expression. SAMBA was able to detect all HPA-1a and -1b alloantibodies recognized by monoclonal antibody-specific immobilization of platelet antigens assay (MAIPA). No cross-reactions between the sera were observed. Two out of seven of the HPA-1a alloantibody-containing sera demonstrated weak to moderate reactivity in MAIPA but strong signals in SAMBA. SAMBA provides a very reliable method for the detection of HPA-1 antibodies with high specificity and sensitivity. This simple and rapid assay can be adapted for use in any routine laboratory and can be potentially adapted for use on automated systems. Copyright © 2013 Elsevier B.V. All rights reserved.
Kong, Xianming; Yu, Qian; Lv, Zhongpeng; Du, Xuezhong
2013-10-11
Tandem assays of protein and glucose in combination with mannose-functionalized Fe3 O4 @SiO2 and Ag@SiO2 tag particles have promising potential in effective magnetic separation and highly sensitive and selective SERS assays of biomaterials. It is for the first time that tandem assay of glucose is developed using SERS based on the Con A-sandwiched microstructures between the functionalized magnetic and tag particles. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
He, Xiaohua; Kong, Qiulian; Patfield, Stephanie; Skinner, Craig; Rasooly, Reuven
2016-01-01
Shiga toxin (Stx) is a common virulence factor of all Shiga toxin producing E. coli (STEC) that cause a wide spectrum of disease, including hemorrhagic colitis and hemolytic uremic syndrome (HUS). Although several commercial kits are available for detection of Stx produced by STEC, none of them are capable of recognizing all subtypes of Stxs, which include three subtypes of Stx1 and seven subtypes of Stx2. New monoclonal and polyclonal antibodies against Stx1 and Stx2 were developed. A universal sandwich ELISA capable of detecting all known subtypes of Stx1 and Stx2 was established using a pool of newly developed antibodies. To precisely monitor the sensitivity of the assay for each subtype of Stxs, recombinant toxoids were created and used as standards in ELISAs. Because of the high affinity of the antibodies incorporated, the ELISA assay is highly sensitive with a limit of detection for the different subtypes of Stx1a and Stx2a between 10 and 50 pg/mL in phosphate buffered saline (PBS). The assay was also able to identify STEC based on the production of Stxs using the supernatants of culture fluids or even single colonies on agar plates without lengthy enrichment in liquid medium. When applied to ground beef samples, this newly developed ELISA was capable of distinguishing beef samples spiked with a single bacterial cell. A highly sensitive and universal assay for all subtypes of Stx1 and Stx2 was developed. It has significantly improved upon the current technologies by avoiding false negative results due to the narrow detection range of the assay. The assay developed in this study can be useful for prompt detection of new and emerging serotypes and screening ground beef samples for contamination of STEC at an early stage in the food supply chain, thus avoiding the need for possible recall.
Serveau-Avesque, Carole; Verger, Robert; Rodriguez, Jorge A; Abousalham, Abdelkarim
2013-09-21
We have designed a convenient, specific, sensitive and continuous lipase assay based on the use of natural triacylglycerols (TAGs) from the Aleurites fordii seed oil which contains α-eleostearic acid (9,11,13,cis,trans,trans-octadecatrienoic acid) and which was coated in the wells of microtiter plates. The coated TAG film cannot be desorbed by the various buffers used during the lipase assay. Upon lipase action, α-eleostearic acid is liberated and desorbed from the interface and then solubilized into the micellar phase. Consequently, the UV absorbance of the α-eleostearic acid is considerably enhanced due to the transformation from an adsorbed to a water soluble state. The lipase activity can be measured continuously by recording the variations with time of the UV absorption spectra. The rate of lipolysis was monitored by measuring the increase of OD at 272 nm, which was found to be linear with time and directly proportional to the amount of added lipase. This microtiter plate lipase assay, based on coated TAGs, presents various advantages as compared to the classical systems: (i) coated TAGs on the microtiter plates could be stored for a long-time at 4 °C, (ii) higher sensitivity in lipase detection, (iii) good reproducibility, and (iv) increase of signal to noise ratio due to high UV absorption after transfer of α-eleostearic acid from an adsorbed to a soluble state. Low concentrations, down to 1 pg mL(-1) of pure Thermomyces lanuginosus or human pancreatic lipase, could be detected under standard assay conditions. The detection sensitivity of this coated method is around 1000 times higher as compared to those obtained with the classical emulsified systems. This continuous high throughput lipase assay could be used to screen new lipases and/or lipase inhibitors present in various biological samples.
Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael
2018-04-06
Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood ("liquid biopsy") is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection.
Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael
2018-01-01
Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood (“liquid biopsy”) is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection. PMID:29719623
Liu, Jikun; Mahtani, Prerna; Zhang, Panhe; Du, Bingchen; Ragupathy, Viswanath; Devadas, Krishnakumar
2016-01-01
Abstract Accurate detection and quantification of HIV-1 group O viruses have been challenging for currently available HIV assays. We have developed a novel time-resolved fluorescence (TRF) europium nanoparticle immunoassay for HIV-1 group O detection using a conventional microplate enzyme-linked immunosorbent assay (ELISA) and a microchip platform. We screened several antibodies for optimal reactivity with several HIV-1 group O strains and identified antibodies that can detect all the strains of HIV-1 group O that were available for testing. The antibodies were used to develop a conventional ELISA format assay and an in-house developed europium nanoparticle-based assay for sensitivity. The method was evaluated on both microwell plate and microchip platforms. We identified two specific and sensitive antibodies among the six we screened. The antibodies, C65691 and ANT-152, were able to quantify 15 and detect all 17 group O viruses, respectively, as they were broadly cross-reactive with all HIV-1 group O strains and yielded better signals compared with other antibodies. We have developed a sensitive assay that reflects the actual viral load in group O samples by using an appropriate combination of p24 antibodies that enhance group O detection and a highly sensitive TRF-based europium nanoparticle for detection. The combination of ANT-152 and C65690M in the ratio 3:1 was able to give significantly higher signals in our europium-based assay compared with using any single antibody. PMID:26978478
Tan, Kah Hin; Ki, Kitti Chan Wing; Watanabe, Satoru; Vasudevan, Subhash G; Krishnan, Manoj
2014-01-01
Large-scale screening of antiviral compounds that target dengue virus life cycle requires a robust cell-based assay that is rapid, easy to conduct, and sensitive enough to be able to assess viral infectivity and cell viability so that antiviral efficacy can be measured. In this chapter we describe a method that uses high-content imaging to evaluate the in vitro antiviral efficacy in a modification to the cell-based flavivirus immunodetection (CFI) assay that was described previously in Wang et al. (Antimicrob Agents Chemother 53(5):1823-1831, 2009).
Development of a real-time RT-PCR assay for a novel influenza A (H1N1) virus.
Jiang, Tao; Kang, Xiaoping; Deng, Yongqiang; Zhao, Hui; Li, Xiaofeng; Yu, Xuedong; Yu, Man; Qin, Ede; Zhu, Qingyu; Yang, Yinhui; Qin, Chengfeng
2010-02-01
A pandemic caused by a novel influenza A virus (H1N1) poses a serious public health threat. In this study, a real-time reverse transcriptase PCR (RT-PCR) assay based on the hemagglutinin gene was developed that discriminates the novel H1N1 from swine influenza virus, seasonal H1N1/H3N2 virus and the highly pathogenic H5N1 avian influenza virus. The sensitivity of this assay was 0.2 50% tissue culture infective dose of virus and 200 copies of in vitro-transcribed target RNA. Three hundred and forty-eight clinical specimens from suspected H1N1 patients were tested using this assay, and forty-two (12.07%) were found to be positive. Tests using the real-time PCR assay recommended by WHO and virus isolation gave identical results. This sensitive and specific real-time RT-PCR assay will contribute to the early diagnosis and control of the emerging H1N1 influenza pandemic. 2009 Elsevier B.V. All rights reserved.
Paudel, Damodar; Jarman, Richard; Limkittikul, Kriengsak; Klungthong, Chonticha; Chamnanchanunt, Supat; Nisalak, Ananda; Gibbons, Robert; Chokejindachai, Watcharee
2011-01-01
Background: Dengue fever and dengue hemorrhagic fever are caused by dengue virus. Dengue infection remains a burning problem of many countries. To diagnose acute dengue in the early phase we improve the low cost, rapid SYBR green real time assay and compared the sensitivity and specificity with real time Taqman® assay and conventional nested PCR assay. Aims: To develop low cost, rapid and reliable real time SYBR green diagnostic dengue assay and compare with Taqman real-time assay and conventional nested PCR (modified Lanciotti). Materials and Methods: Eight cultured virus strains were diluted in tenth dilution down to undetectable level by the PCR to optimize the primer, temperature (annealing, and extension and to detect the limit of detection of the assay. Hundred and ninety three ELISA and PCR proved dengue clinical samples were tested with real time SYBR® Green assay, real time Taqman® assay to compare the sensitivity and specificity. Results: Sensitivity and specificity of real time SYBR® green dengue assay (84% and 66%, respectively) was almost comparable to those (81% and 74%) of Taqman real time PCR dengue assay. Real time SYBR® green RT-PCR was equally sensitive in primary and secondary infection while real time Taqman was less sensitive in the secondary infection. Sensitivity of real time Taqman on DENV3 (87%) was equal to SYBR green real time PCR dengue assay. Conclusion: We developed low cost rapid diagnostic SYBR green dengue assay. Further study is needed to make duplex primer assay for the serotyping of dengue virus. PMID:22363089
Functionalized Gold Nanoparticles for the Detection of C-Reactive Protein
António, Maria
2018-01-01
C-reactive protein (CRP) is a very important biomarker of infection and inflammation for a number of diseases. Routine CRP measurements with high sensitivity and reliability are highly relevant to the assessment of states of inflammation and the efficacy of treatment intervention, and require the development of very sensitive, selective, fast, robust and reproducible assays. Gold nanoparticles (Au NPs) are distinguished for their unique electrical and optical properties and the ability to conjugate with biomolecules. Au NP-based probes have attracted considerable attention in the last decade in the analysis of biological samples due to their simplicity, high sensitivity and selectivity. Thus, this article aims to be a critical and constructive analysis of the literature of the last three years regarding the advances made in the development of bioanalytical assays based on gold nanoparticles for the in vitro detection and quantification of C-reactive protein from biological samples. Current methods for Au NP synthesis and the strategies for surface modification aiming at selectivity towards CRP are highlighted. PMID:29597295
Aptamer-conjugated nanoparticles for cancer cell detection.
Medley, Colin D; Bamrungsap, Suwussa; Tan, Weihong; Smith, Joshua E
2011-02-01
Aptamer-conjugated nanoparticles (ACNPs) have been used for a variety of applications, particularly dual nanoparticles for magnetic extraction and fluorescent labeling. In this type of assay, silica-coated magnetic and fluorophore-doped silica nanoparticles are conjugated to highly selective aptamers to detect and extract targeted cells in a variety of matrixes. However, considerable improvements are required in order to increase the selectivity and sensitivity of this two-particle assay to be useful in a clinical setting. To accomplish this, several parameters were investigated, including nanoparticle size, conjugation chemistry, use of multiple aptamer sequences on the nanoparticles, and use of multiple nanoparticles with different aptamer sequences. After identifying the best-performing elements, the improvements made to this assay's conditional parameters were combined to illustrate the overall enhanced sensitivity and selectivity of the two-particle assay using an innovative multiple aptamer approach, signifying a critical feature in the advancement of this technique.
Spectroscopy on the wing: naturally inspired SERS substrates for biochemical analysis.
Garrett, Natalie L; Vukusic, Peter; Ogrin, Feodor; Sirotkin, Evgeny; Winlove, C Peter; Moger, Julian
2009-03-01
We show that naturally occurring chitinous nanostructures found on the wings of the Graphium butterfly can be used as substrates for surface-enhanced Raman scattering when coated with a thin film of gold or silver. The substrates were found to exhibit excellent biocompatibility and sensitivity, making them ideal for protein assaying. An assay using avidin/biotin binding showed that the substrates could be used to quantify protein binding directly from changes in the surface-enhanced Raman scattering (SERS) spectra and were sensitive over a concentration range comparable with a typical enzyme-linked immunosorbent assays (ELISA) assay. A biomimetic version of the wing nanostructures produced using a highly reproducible, large-scale fabrication process, yielded comparable enhancement factors and biocompatibility. The excellent biocompatibility of the wings and biomimetic substrates is unparalleled by other lithographically produced substrates, and this could pave the way for widespread application of ultrasensitive SERS-based bioassays.
Zheng, Zhi; Luo, Yuling; McMaster, Gary K
2006-07-01
Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.
Al-Turab, Mariam; Chehadeh, Wassim; Al-Mulla, Fahd; Al-Nakib, Widad
2012-04-01
Human metapneumovirus (hMPV) is a respiratory pathogen that was discovered in 2001 and is considered a major cause of both upper and lower respiratory tract infections. A sensitive, fast, and high-throughput diagnostic test is needed for the detection of hMPV that may assist in the clinical management as well as in the reduction of inappropriate therapy. Therefore, a comparison assessment was performed in this study between the PrimerDesign™ genesig real-time reverse transcription-polymerase chain reaction (RT-PCR) Assay and the INFINITI(®) Respiratory Viral Panel Plus Assay (RVP-Plus) for the detection of hMPV infection in patients with respiratory tract infections. A total of 200 respiratory samples were collected from 185 hospitalized patients, during the winter season in Kuwait. Of 185 patients, 10 (5.4%) were positive for hMPV RNA by the in-house RT-PCR assay, while 7 (4%) were positive for hMPV RNA by the real-time RT-PCR assay and 9 (5%) were positive for hMPV RNA by the INFINITI(®) RVP-Plus assay. The high incidence rate (60%) of hMPV infection was in January 2011. The sensitivity of the real-time RT-PCR and INFINITI(®) RVP-Plus assays was 70% and 90%, respectively, with specificity of 100% for both assays. hMPV types A and B could be identified in this study; however, discordant genotyping results were found between the direct sequencing method and the INFINITI(®) RVP-Plus assay in 33% of hMPV-positive patients. Copyright © 2012 Elsevier Inc. All rights reserved.
2010-01-01
Background The cardiac troponins are biomarkers used for diagnosis of myocardial injury. They are also powerful prognostic markers in many diseases and settings. Recently introduced high-sensitivity assays indicate that chronic cardiac troponin elevations are common in response to cardiovascular (CV) morbidity. Type 2 diabetes mellitus (T2DM) confers a high risk of CV disease, but little is known about chronic cardiac troponin elevations in diabetic subjects. Accordingly, we aimed to understand the prevalence, determinants, and prognostic implications of cardiac troponin T (cTnT) elevations measured with a high-sensitivity assay in patients with T2DM. Methods cTnT was measured in stored, frozen serum samples from 124 subjects enrolled in the Asker and Bærum Cardiovascular Diabetes trial at baseline and at 2-year follow-up, if availabe (96 samples available). Results were analyzed in relation to baseline variables, hospitalizations, and group assignment (multifactorial intensive versus conventional diabetes care for lowering CV risk). Results One-hundred thirteen (90 %) had detectable cTnT at baseline and of those, 22 (18 % of the total population) subjects had values above the 99th percentile for healthy controls (13.5 ng/L). Levels at baseline were associated with conventional CV risk factors (age, renal function, gender). There was a strong correlation between cTnT levels at the two time-points (r = 0.92, p > 0.001). Risk for hospitalizations during follow-up increased step-wise by quartiles of hscTnT measured at baseline (p = 0.058). Conclusions Elevations of cTnT above the 99th percentile measured by a highly sensitive assay were encountered frequently in a population of T2DM patients. cTnT levels appeared to be stable over time and associated with conventional CV risk factors. Although a clear trend was present, no statistically robust associations with adverse outcomes could be found. PMID:20843304
Hallén, Jonas; Johansen, Odd Erik; Birkeland, Kåre I; Gullestad, Lars; Aakhus, Svend; Endresen, Knut; Tjora, Solve; Jaffe, Allan S; Atar, Dan
2010-09-15
The cardiac troponins are biomarkers used for diagnosis of myocardial injury. They are also powerful prognostic markers in many diseases and settings. Recently introduced high-sensitivity assays indicate that chronic cardiac troponin elevations are common in response to cardiovascular (CV) morbidity. Type 2 diabetes mellitus (T2DM) confers a high risk of CV disease, but little is known about chronic cardiac troponin elevations in diabetic subjects. Accordingly, we aimed to understand the prevalence, determinants, and prognostic implications of cardiac troponin T (cTnT) elevations measured with a high-sensitivity assay in patients with T2DM. cTnT was measured in stored, frozen serum samples from 124 subjects enrolled in the Asker and Bærum Cardiovascular Diabetes trial at baseline and at 2-year follow-up, if available (96 samples available). Results were analyzed in relation to baseline variables, hospitalizations, and group assignment (multifactorial intensive versus conventional diabetes care for lowering CV risk). One-hundred thirteen (90%) had detectable cTnT at baseline and of those, 22 (18% of the total population) subjects had values above the 99th percentile for healthy controls (13.5 ng/L). Levels at baseline were associated with conventional CV risk factors (age, renal function, gender). There was a strong correlation between cTnT levels at the two time-points (r=0.92, p>0.001). Risk for hospitalizations during follow-up increased step-wise by quartiles of hscTnT measured at baseline (p=0.058). Elevations of cTnT above the 99th percentile measured by a highly sensitive assay were encountered frequently in a population of T2DM patients. cTnT levels appeared to be stable over time and associated with conventional CV risk factors. Although a clear trend was present, no statistically robust associations with adverse outcomes could be found.
Basavanna, Uma; Muruvanda, Tim; Brown, Eric W.; Sharma, Shashi K.
2013-01-01
The standard procedure for definitive detection of BoNT-producing Clostridia is a culture method combined with neurotoxin detection using a standard mouse bioassay (MBA). The mouse bioassay is highly sensitive and specific, but it is expensive and time-consuming, and there are ethical concerns due to use of laboratory animals. Cell-based assays provide an alternative to the MBA in screening for BoNT-producing Clostridia. Here, we describe a cell-based assay utilizing a fluorescence reporter construct expressed in a neuronal cell model to study toxin activity in situ. Our data indicates that the assay can detect as little as 100 pM BoNT/A activity within living cells, and the assay is currently being evaluated for the analysis of BoNT in food matrices. Among available in vitro assays, we believe that cell-based assays are widely applicable in high-throughput screenings and have the potential to at least reduce and refine animal assays if not replace it. PMID:23533420
2011-01-01
Background Eimeria parasites can cause the disease coccidiosis in poultry and even subclinical infection can incur economic loss. Diagnosis of infection predominantly relies on traditional techniques including lesion scoring and faecal microscopy despite the availability of sensitive molecular assays, largely due to cost and the requirement for specialist equipment. Despite longstanding proven efficacy these traditional techniques demand time and expertise, can be highly subjective and may under-diagnose subclinical disease. Recognition of the tight economic margins prevailing in modern poultry production and the impact of avian coccidiosis on poverty in many parts of the world has highlighted a requirement for a panel of straightforward and sensitive, but cost-effective, Eimeria species-specific diagnostic assays. Results Loop-mediated isothermal amplification (LAMP) is an uncomplicated, quick and relatively inexpensive diagnostic tool. In this study we have developed a panel of species-specific LAMP assays targeting the seven Eimeria species that infect the chicken. Each assay has been shown to be genuinely species-specific with the capacity to detect between one and ten eimerian genomes, equivalent to less than a single mature schizont. Development of a simple protocol for template DNA preparation from tissue collected post mortem with no requirement for specialist laboratory equipment supports the use of these assays in routine diagnosis of eimerian infection. Preliminary field testing supports this hypothesis. Conclusions Development of a panel of sensitive species-specific LAMP assays introduces a valuable new cost-effective tool for use in poultry husbandry. PMID:22053893
Paris, Daniel H; Blacksell, Stuart D; Nawtaisong, Pruksa; Jenjaroen, Kemajittra; Teeraratkul, Achara; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Kantipong, Pacharee; Day, Nicholas P J
2011-09-01
There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.
Yu, Hye-Weon; Jang, Am; Kim, Lan Hee; Kim, Sung-Jo; Kim, In S
2011-09-15
Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.
Lordkipanidzé, Marie; Lowe, Gillian C; Kirkby, Nicholas S; Chan, Melissa V; Lundberg, Martina H; Morgan, Neil V; Bem, Danai; Nisar, Shaista P; Leo, Vincenzo C; Jones, Matthew L; Mundell, Stuart J; Daly, Martina E; Mumford, Andrew D; Warner, Timothy D; Watson, Steve P
2014-02-20
Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167.
Olivier, T T; Viljoen, I M; Hofmeyr, J; Hausler, G A; Goosen, W J; Tordiffe, A S W; Buss, P; Loxton, A G; Warren, R M; Miller, M A; van Helden, P D; Parsons, S D C
2017-06-01
Mycobacterium bovis infection, the cause of bovine tuberculosis (BTB), is endemic in wildlife in the Kruger National Park (KNP), South Africa. In lions, a high infection prevalence and BTB mortalities have been documented in the KNP; however, the ecological consequences of this disease are currently unknown. Sensitive assays for the detection of this infection in this species are therefore required. Blood from M. bovis-exposed, M. bovis-unexposed, M. tuberculosis-exposed and M. bovis-infected lions was incubated in QuantiFERON ® -TB Gold (QFT) tubes containing either saline or ESAT-6/CFP-10 peptides. Using qPCR, selected reference genes were evaluated for expression stability in these samples and selected target genes were evaluated as markers of antigen-dependent immune activation. The abundance of monokine induced by gamma interferon (MIG/CXCL9) mRNA, measured in relation to that of YWHAZ, was used as a marker of ESAT-6/CFP-10 sensitization. The gene expression assay results were compared between lion groups, and lenient and stringent diagnostic cut-off values were calculated. This CXCL9 gene expression assay combines a highly specific stimulation platform with a sensitive diagnostic marker that allows for discrimination between M. bovis-infected and M. bovis-uninfected lions. © 2015 Blackwell Verlag GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenko, Kathryn; Zhang, Yanfeng; Kostenko, Yulia
Plant and microbial toxins are considered bioterrorism threat agents because of their extreme toxicity and/or ease of availability. Additionally, some of these toxins are increasingly responsible for accidental food poisonings. The current study utilized an ELISA-based protein antibody microarray for the multiplexed detection of ten biothreat toxins, botulinum neurotoxins (BoNT) A, B, C, D, E, F, ricin, shiga toxins 1 and 2 (Stx), and staphylococcus enterotoxin B (SEB), in buffer and complex biological matrices. The multiplexed assay displayed a sensitivity of 1.3 pg/mL (BoNT/A, BoNT/B, SEB, Stx-1 and Stx-2), 3.3 pg/mL (BoNT/C, BoNT/E, BoNT/F) and 8.2 pg/mL (BoNT/D, ricin). Allmore » assays demonstrated high accuracy (75-120 percent recovery) and reproducibility (most coefficients of variation < 20%). Quantification curves for the ten toxins were also evaluated in clinical samples (serum, plasma, nasal fluid, saliva, stool, and urine) and environmental samples (apple juice, milk and baby food) with overall minimal matrix effects. The multiplex assays were highly specific, with little crossreactivity observed between the selected toxin antibodies. The results demonstrate a multiplex microarray that improves current immunoassay sensitivity for biological warfare agents in buffer, clinical, and environmental samples.« less
Robust Detection of Rare Species Using Environmental DNA: The Importance of Primer Specificity
Wilcox, Taylor M.; McKelvey, Kevin S.; Young, Michael K.; Jane, Stephen F.; Lowe, Winsor H.; Whiteley, Andrew R.; Schwartz, Michael K.
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method’s sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design. PMID:23555689
Robust detection of rare species using environmental DNA: the importance of primer specificity.
Wilcox, Taylor M; McKelvey, Kevin S; Young, Michael K; Jane, Stephen F; Lowe, Winsor H; Whiteley, Andrew R; Schwartz, Michael K
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method's sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design.
Anaphylaxis to Gelofusine confirmed by in vitro basophil activation test: a case series.
Apostolou, E; Deckert, K; Puy, R; Sandrini, A; de Leon, M P; Douglass, J A; Rolland, J M; O'hehir, R E
2006-03-01
The plasma expander Gelofusine (succinylated gelatin) is a recognised cause of peri-operative anaphylaxis. Current diagnosis of Gelofusine sensitivity is by skin testing, a procedure that itself carries a risk of allergic reaction. We evaluated the reliability of the in vitro basophil activation test as a diagnostic assay for Gelofusine sensitivity in subjects with a clinical history highly suggestive of Gelofusine allergy. Six patients with peri-operative anaphylaxis clinically attributed to Gelofusine were skin tested to confirm sensitivity. Control subjects included three healthy subjects and five subjects allergic to a neuromuscular blocking drug, all negative on Gelofusine skin testing. Whole blood basophil activation to Gelofusine was analysed by flow cytometry for CD63 surface expression. All of the Gelofusine sensitive patients and one of the control allergic subjects showed positive basophil activation to Gelofusine. In this series of subjects, the basophil activation test for Gelofusine allergy had a sensitivity of 100% and a specificity of 87.5%. Our findings suggest that basophil activation testing is a safe and reliable in vitro assay for prediction or confirmation of Gelofusine sensitivity in patients with high clinical suspicion of Gelofusine-induced anaphylaxis.
Yang, Ruifeng; Song, Guangjun; Guan, Wenli; Wang, Qian; Liu, Yan; Wei, Lai
2016-02-01
Qualitative HBsAg assay is used to screen HBV infection for decades. The utility of quantitative assay is also rejuvenated recently. We aimed to evaluate and compare the performance of a novel ultra-sensitive and quantitative assay, the Lumipulse assay, with the Architect and Elecsys assays. As screening methods, specificity was compared using 2043 consecutive clinical routine samples. As quantitative assays, precision and accuracy were assessed. Sera from 112 treatment-naïve chronic hepatitis B patients, four patients undergoing antiviral therapy and one patient with acute infection were tested to compare the correlations. Samples with concurrent HBsAg/anti-HBs were also quantified. The Lumipulse assay precisely quantified ultra-low level of HBsAg (0.004 IU/mL). It identified additional 0.98% (20/2043) clinical samples with trance amount of HBsAg. Three assays displayed excellent linear correlations irrespective of genotypes and S-gene mutations (R(2)>0.95, P<0.0001), while minor quantitative biases existed. The Lumipulse assay did not yield higher HBsAg concentrations in samples with concomitant anti-HBs. Compared with other assays, the Lumipulse assay is sensitive and specific for detecting HBsAg. The interpretation of the extremely low-level results, however, is challenging. Quantitative HBsAg results by different assays are highly correlated, but they should be interpreted interchangeably only after conversion to eliminate the biases. Copyright © 2015 Elsevier B.V. All rights reserved.
Coakley, Eoin; Reeves, Jacqueline D; Huang, Wei; Mangas-Ruiz, Marga; Maurer, Irma; Harskamp, Agnes M; Gupta, Soumi; Lie, Yolanda; Petropoulos, Christos J; Schuitemaker, Hanneke; van 't Wout, Angélique B
2009-11-01
The recent availability of CCR5 antagonists as anti-human immunodeficiency virus (anti-HIV) therapeutics has highlighted the need to accurately identify CXCR4-using variants in patient samples when use of this new drug class is considered. The Trofile assay (Monogram Biosciences) has become the method that is the most widely used to define tropism in the clinic prior to the use of a CCR5 antagonist. By comparison, the MT-2 assay has been used since early in the HIV epidemic to define tropism in clinical specimens. Given that there are few data from direct comparisons of these two assays, we evaluated the performance of the plasma-based Trofile assay and the peripheral blood mononuclear cell (PBMC)-based MT-2 assay for the detection of CXCR4 use in defining the tropism of HIV isolates derived from clinical samples. The various samples used for this comparison were derived from participants of the Amsterdam Cohort Studies on HIV infection and AIDS who underwent consecutive MT-2 assay testing of their PBMCs at approximately 3-month intervals. This unique sample set was specifically selected because consecutive MT-2 assays had demonstrated a shift from negative to positive in PBMCs, reflecting the first emergence of CXCR4-using virus in PBMCs above the level of detection of the assay in these individuals. Trofile testing was performed with clonal HIV type 1 (HIV-1) variants (n = 21), MT-2 cell culture-derived cells (n = 20) and supernatants (n = 42), and plasma samples (n = 76). Among the clonal HIV-1 variants and MT-2 cell culture-derived samples, the results of the Trofile and MT-2 assays demonstrated a high degree of concordance (95% to 98%). Among consecutive plasma samples, detection of CXCR4-using virus was at or before the time of first detection by the MT-2 assay in 5/10 patients by the original Trofile assay and in 9/10 patients by the enhanced-sensitivity Trofile assay. Differences in the time to the first detection of CXCR4 use between the MT-2 assay (PBMCs) and the original Trofile assay (plasma) were greatly reduced by the enhanced-sensitivity Trofile assay, suggesting that sensitivity for the detection of minor CXCR4-using variants may be a more important determinant of discordant findings than compartmentalization. The similarities in performance of the enhanced-sensitivity Trofile and MT-2 assays suggest that either may be an appropriate methodology to define tropism in patient specimens.
Detection of Streptococcus pyogenes using rapid visual molecular assay.
Zhao, Xiangna; He, Xiaoming; Li, Huan; Zhao, Jiangtao; Huang, Simo; Liu, Wei; Wei, Xiao; Ding, Yiwei; Wang, Zhaoyan; Zou, Dayang; Wang, Xuesong; Dong, Derong; Yang, Zhan; Yan, Xiabei; Huang, Liuyu; Du, Shuangkui; Yuan, Jing
2015-09-01
Streptococcus pyogenes is an increasingly important pathogen in many parts of the world. Rapid and accurate detection of S. pyogenes aids in the control of the infection. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed and validated for the specific detection of S. pyogenes. The assay incorporates two methods: a chromogenic analysis using a calcein/Mn(2+) complex and real-time turbidity monitoring to assess the reaction. Both methods detected the target DNA within 60 min under 64°C isothermal conditions. The assay used specifically designed primers to target spy1258, and correctly identified 111 strains of S. pyogenes and 32 non-S. pyogenes strains, including other species of the genus Streptococcus. Tests using reference strains showed that the LAMP assay was highly specific. The sensitivity of the assay, with a detection limit of 1.49 pg DNA, was 10-fold greater than that of PCR. The LAMP assay established in this study is simple, fast and sensitive, and does not rely upon any special equipment; thus, it could be employed in clinical diagnosis. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
An enzymatic fluorescent assay for the quantification of phosphite in a microtiter plate format.
Berkowitz, Oliver; Jost, Ricarda; Pearse, Stuart J; Lambers, Hans; Finnegan, Patrick M; Hardy, Giles E St J; O'Brien, Philip A
2011-05-01
A sensitive fluorometric assay for the quantification of phosphite has been developed. The assay uses the enzymatic oxidation of phosphite to phosphate by a recombinant phosphite dehydrogenase with NAD(+) as cosubstrate to produce the highly fluorescent reaction product resorufin. The optimized assay can be carried out in a 96-well microtiter plate format for high-throughput screening purposes and has a detection limit of 0.25 nmol phosphite. We used the method to quantify phosphite levels in plant tissue extracts and to determine phosphite dehydrogenase activity in transgenic plants. The assay is suitable for other biological or environmental samples. Because phosphite is a widely used fungicide to protect plants from pathogenic oomycetes, the assay provides a cost-effective and easy-to-use method to monitor the fate of phosphite following application. Copyright © 2011 Elsevier Inc. All rights reserved.
Evaluation of a new ultrasensitive assay for cardiac troponin I.
Casals, Gregori; Filella, Xavier; Bedini, Josep Lluis
2007-12-01
We evaluated the analytical and clinical performance of a new ultrasensitive cardiac troponin I assay (cTnI) on the ADVIA Centaur system (TnI-Ultra). The evaluation included the determination of detection limit, within-assay and between-assay variation and comparison with two other non-ultrasensitive methods. Moreover, cTnI was determined in 120 patients with acute chest pain with three methods. To evaluate the ability of the new method to detect MI earlier, it was assayed in 8 MI patients who first tested negative then positive by the other methods. The detection limit was 0.009 microg/L and imprecision was <10% at all concentrations evaluated. In comparison with two other methods, 10% of the anginas diagnosed were recategorized to MI. The ADVIA Centaur TnI-Ultra assay presented high reproducibility and high sensitivity. The use of the recommended lower cutpoint (0.044 microg/L) implied an increased and earlier identification of MI.
Qian, Zhaosheng; Chai, Lujing; Tang, Cong; Huang, Yuanyuan; Chen, Jianrong; Feng, Hui
2015-03-03
A convenient, reliable, and highly sensitive real-time assay for alkaline phosphatase (ALP) activity in the continuous and recyclable way is established on the basis of aggregation and disaggregation of carbon quantum dots (CQDs) through the competitive assay approach. CQDs and adenosine triphosphate (ATP) were used as the fluorescent indicator and substrate for ALP activity assessment, respectively. Richness of carboxyl groups on the surface of CQDs enables their severe aggregation triggered by cerium ions, which results in effective fluorescence quenching. Under the catalytic hydrolysis of ALP, ATP can be rapidly transformed to phosphate ions. Stronger affinity of phosphate ions to cerium ions than carboxyl groups is taken advantage of to achieve fluorescence recovery induced by redispersion of CQDs in the presence of ALP and ATP. Quantitative evaluation of ALP activity in a broad range from 4.6 to 383.3 U/L with the detection limit of 1.4 U/L can be realized in this way, which endows the assay with high enough sensitivity for practical detection in human serum. The assay can be used in a recyclable way for more than three times since the generated product CePO4 as a precipitate can be easily removed from the standard assay system. This strategy broadens the sensing application of fluorescent CQDs with excellent biocompatibility and provides an example based on disaggregation in optical probe development.
Evaluation of a PCR/ESI-MS platform to identify respiratory viruses from nasopharyngeal aspirates.
Lin, Yong; Fu, Yongfeng; Xu, Menghua; Su, Liyun; Cao, Lingfeng; Xu, Jin; Cheng, Xunjia
2015-11-01
Acute respiratory tract infection is a major cause of morbidity and mortality worldwide, particularly in infants and young children. High-throughput, accurate, broad-range tools for etiologic diagnosis are critical for effective epidemic control. In this study, the diagnostic capacities of an Ibis platform based on the PCR/ESI-MS assay were evaluated using clinical samples. Nasopharyngeal aspirates (NPAs) were collected from 120 children (<5 years old) who were hospitalized with lower respiratory tract infections between November 2010 and October 2011. The respiratory virus detection assay was performed using the PCR/ESI-MS assay and the DFA. The discordant PCR/ESI-MS and DFA results were resolved with RT-PCR plus sequencing. The overall agreement for PCR/ESI-MS and DFA was 98.3% (118/120). Compared with the results from DFA, the sensitivity and specificity of the PCR/ESI-MS assay were 100% and 97.5%, respectively. The PCR/ESI-MS assay also detected more multiple virus infections and revealed more detailed subtype information than DFA. Among the 12 original specimens with discordant results between PCR/ESI-MS and DFA, 11 had confirmed PCR/ESI-MS results. Thus, the PCR/ESI-MS assay is a high-throughput, sensitive, specific and promising method to detect and subtype conventional viruses in respiratory tract infections and allows rapid identification of mixed pathogens. © 2015 Wiley Periodicals, Inc.
di Rienzo, Valentina; Bubici, Giovanni; Montemurro, Cinzia; Cillo, Fabrizio
2018-01-01
In tomato, resistance to Tomato spotted wilt virus (TSWV) is conferred by the dominant gene, designated Sw-5. Virulent Sw-5 resistance breaking (SRB) mutants of TSWV have been reported on Sw-5 tomato cultivars. Two different PCR-based allelic discrimination techniques, namely Custom TaqMan™ SNP Genotyping and high-resolution melting (HRM) assays, were developed and compared for their ability to distinguish between avirulent (Sw-5 non-infecting, SNI) and SRB biotypes. TaqMan assays proved to be more sensitive (threshold of detection in a range of 50-70 TSWV RNA copies) and more reliable than HRM, assigning 25 TSWV isolates to their correct genotype with an accuracy of 100%. Moreover, the TaqMan SNP assays were further improved developing a rapid and simple protocol that included crude leaf extraction for RNA template preparations. On the other hand, HRM assays showed higher levels of sensitivity than TaqMan when used to co-detect both biotypes in different artificial mixtures. These diagnostic assays contributed to gain preliminary information on the epidemiology of TSWV isolates in open field conditions. In fact, the presented data suggest that SRB isolates are present as stable populations established year round, persisting on both winter (globe artichoke) and summer (tomato) crops, in the same cultivated areas of Southern Italy.
Jung, Se-Hui; Ji, Su-Hyun; Han, Eun-Taek; Park, Won Sun; Hong, Seok-Ho; Kim, Young-Myeong; Ha, Kwon-Soo
2016-05-15
Glucose-6-phosphate dehydrogenase (G6PD) regulates nicotinamide adenine dinucleotide phosphate (NADPH) levels and is related to the pathogenesis of various diseases, including G6PD deficiency, type 2 diabetes, aldosterone-induced endothelial dysfunction, and cancer. Therefore, a highly sensitive array-based assay for determining quantitative G6PD activity is required. Here, we developed an on-chip G6PD activity assay using liquid droplet fluorescence arrays. Quantitative G6PD activity was determined by calculating reduced resorufin concentrations in liquid droplets. The limit of detection (LOD) of this assay was 0.162 mU/ml (2.89 pM), which is much more sensitive than previous assays. We used our activity assay to determine kinetic parameters, including Michaelis-Menten constants (Km) and maximum rates of enzymatic reaction (Vmax) for NADP(+) and G6P, and half-maximal inhibitory concentrations (IC50). We successfully applied this new assay to determine G6PD activity in human plasma from normal healthy individuals (n=30) and patients with inflammation (n=30). The inflammatory group showed much higher G6PD activities than did the normal group (p<0.001), with a high area under the curve value of 0.939. Therefore, this new activity assay has the potential to be used for diagnosis of G6PD-associated diseases and utilizing kinetic studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Cunnion, Kenji M; Hair, Pamela S; Krishna, Neel K; Sass, Megan A; Enos, Clinton W; Whitley, Pamela H; Maes, Lanne Y; Goldberg, Corinne L
2017-03-01
The agglutination-based cross-matching method is sensitive for antibody binding to red blood cells but is only partially predictive of complement-mediated hemolysis, which is important in many acute hemolytic transfusion reactions. Here, we describe complement hemolysis using human erythrocytes (CHUHE) assays that directly evaluate complement-mediated hemolysis between individual serum-plasma and red blood cell combinations. The CHUHE assay is used to evaluate correlations between agglutination titers and complement-mediated hemolysis as well as the hemolytic potential of plasma from type A blood donors. Plasma or serum from each type A blood donor was incubated with AB or B red blood cells in the CHUHE assay and measured for free hemoglobin release. CHUHE assays for serum or plasma demonstrate a wide, dynamic range and high sensitivity for complement-mediated hemolysis for individual serum/plasma and red blood cell combinations. CHUHE results suggest that agglutination assays alone are only moderately predictive of complement-mediated hemolysis. CHUHE results also suggest that plasma from particular type A blood donors produce minimal complement-mediated hemolysis, whereas plasma from other type A blood donors produce moderate to high-level complement-mediated hemolysis, depending on the red blood cell donor. The current results indicate that the CHUHE assay can be used to assess complement-mediated hemolysis for plasma or serum from a type A blood donor, providing additional risk discrimination over agglutination titers alone. © 2016 AABB.
Detection of low-level DNA mutation by ARMS-blocker-Tm PCR.
Qu, Shoufang; Liu, Licheng; Gan, Shuzhen; Feng, Huahua; Zhao, Jingyin; Zhao, Jing; Liu, Qi; Gao, Shangxiang; Chen, Weijun; Wang, Mengzhao; Jiang, Yongqiang; Huang, Jie
2016-02-01
Low-level DNA mutations play important roles in cancer prognosis and treatment. However, most existing methods for the detection of low-level DNA mutations are insufficient for clinical applications because of the high background of wild-type DNA. In this study, a novel assay based on Tm-dependent inhibition of wild type template amplification was developed. The defining characteristic of this assay is an additional annealing step was introduced into the ARMS-blocker PCR. The temperature of this additional annealing step is equal to the Tm of the blocker. Due to this additional annealing step, the blocker can preferentially and specifically bind the wild-type DNA. Thus, the inhibition of wild type template is realized and the mutant DNA is enriched. The sensitivity of this assay was between 10(-4) and 10(-5), which is approximately 5 to 10 times greater than the sensitivity of the assay without the additional annealing step. To evaluate the performance of this assay in detecting K-ras mutation, we analyzed 100 formalin-fixed paraffin-embedded (FFPE) specimens from colorectal cancer patients using this new assay and Sanger sequencing. Of the clinical samples, 27 samples were positive for K-ras mutation by both methods. Our results indicated that this new assay is a highly selective, convenient, and economical method for detecting rare mutations in the presence of higher concentrations of wild-type DNA. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
The local lymph node assay and skin sensitization: a cut-down screen to reduce animal requirements?
Kimber, Ian; Dearman, Rebecca J; Betts, Catherine J; Gerberick, G Frank; Ryan, Cindy A; Kern, Petra S; Patlewicz, Grace Y; Basketter, David A
2006-04-01
The local lymph node assay (LLNA), an alternative approach to skin-sensitizing testing, has made a significant contribution to animal welfare by permitting a reduction and refinement of animal use. Although there is clearly an aspiration to eliminate the use of animals in such tests, it is appropriate also to consider other opportunities for refinement and reduction of animal use. We have therefore explored the use of a modified version of the LLNA for screening purposes when there is a need to evaluate the sensitizing activity of a large number of chemicals, as will be the case under the auspices of registration, evaluation and authorization of chemicals (REACH). Using an existing LLNA database of 211 chemicals, we have examined whether a cut-down assay comprising a single high-dose group and a concurrent vehicle control would provide a realistic approach for screening chemicals for sensitizing potential. The analyses reported here suggest this is the case. We speculate that the animal welfare benefits may be enhanced further by reducing the number of animals per experimental group. However, a detailed evaluation will be necessary to provide reassurance that a reduction in group size would provide adequate sensitivity across a range of skin sensitization potencies.
Pape, B E; Cary, P L; Clay, L C; Godolphin, W
1983-01-01
Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.
USDA-ARS?s Scientific Manuscript database
Real-time PCR is a highly sensitive, relatively easy to perform assay for quantifying mRNA abundance. However, there are several complexities built into the assay that can affect data interpretation. Most notably, the selection of an appropriate internal control for normalization is essential for ...
Dalla Valle, L; Toffolo, V; Lamprecht, M; Maltese, C; Bovo, G; Belvedere, P; Colombo, L
2005-10-31
The aim of the present work was to develop two new independent SYBR Green I-based real-time PCR assays for both detection and quantification of betanodavirus, an RNA virus that infects several species of marine teleost fish causing massive mortalities in larvae and juveniles. The assays utilized two pairs of primers targeting highly conserved regions of both the RNA molecules forming the betanodavirus genome: RNA1 encoding the RNA-dependent RNA polymerase (RdRP) and RNA2 encoding the coat protein (CP). The specificity of amplifications was monitored by the melting analysis and agarose gel electrophoresis of the amplified products. The applicability of these assays was confirmed with 21 betanodavirus strains, covering all the four main clades. In addition, a BLAST (NCBI) search with the primer sequences showed no genomic cross-reactivity with other viruses. The new assays were able to quantify concentrations of betanodavirus genes ranging from 10(1) to 10(8) copies per reaction. The intra-assay coefficients of variation (CV) of threshold cycle (Ct) values of the assays were 1.5% and 1.4% for CP and RdRP RNAs, respectively. The inter-assay CVs of Ct values were 2.3% and 2.4% for CP and RdRP RNAs, respectively. Moreover, regression analysis showed a significant correlation (R2>0.97) between genome number, as determined by real-time PCR assays and the corresponding virus titer expressed as TCID50/ml of two different betanodavirus strains propagated in cell culture. The two assays were compared with a previously established one-step RT-PCR assay and with the classical virus isolation test and found to be more sensitive. In conclusion, the developed real-time RT-PCR assays are a reliable, specific and sensitive tool for the quantitative diagnosis of betanodavirus.
Fazelahi, Mansoureh; Kia, Vahid; Kaghazian, Hooman; Paryan, Mahdi
2017-11-26
Recombinant streptokinase is a biopharmaceutical which is usually produced in E. coli. Residual DNA as a contamination and risk factor may remain in the product. It is necessary to control the production procedure to exclude any possible contamination. The aim of the present study was to develop a highly specific and sensitive quantitative real-time PCR-based method to determine the amount of E. coli DNA in recombinant streptokinase. A specific primers and a probe was designed to detect all strains of E. coli. To determine the specificity, in addition to using NCBI BLASTn, 28 samples including human, bacterial, and viral genomes were used. The results confirmed that the assay detects no genomic DNA but E. coli's and the specificity was determined to be 100%. To determine the sensitivity and limit of detection of the assay, a 10-fold serial dilution (10 1 to 10 7 copies/µL) was tested in triplicate. The sensitivity of the test was determined to be 101 copies/µL or 35 fg/µL. Inter-assay and intra-assay were determined to be 0.86 and 1.69%, respectively. Based on the results, this assay can be used as an accurate method to evaluate the contamination of recombinant streptokinase in E. coli.
Lee, Chi-Tsung; Hsiao, Kuang-Ming; Chen, Jin-Cherng; Su, Cheng-Chuan
2015-11-01
Acute bacterial meningitis causes high morbidity and mortality; the associated clinical symptoms often are insensitive or non-specific; and the pathogenic bacteria are geographically diverse. Clinical diagnosis requires a rapid and accurate methodology. This study aimed to develop a new multiplex polymerase chain reaction (mPCR) assay to detect simultaneously six major bacteria that cause adult bacterial meningitis in Taiwan: Klebsiella pneumoniae, Pseudomonas aeruginosa, Streptococcus pneumoniae, Staphylococcus aureus, Escherichia coli, and Acinetobacter baumannii. Species-specific primers for the six bacteria were developed using reference strains. The specificities of the mPCRs for these bacteria were validated, and the sensitivities were evaluated via serial dilutions. The mPCR assay specifically detected all of the six pathogens, particularly with sensitivities of 12 colony forming units (CFU)/mL, 90 CFU/mL, and 390 CFU/mL for E. coli, S. pneumoniae, and K. pneumoniae, respectively. This mPCR assay is a rapid and specific tool to detect the six major bacterial pathogens that cause acute adult meningitis in Taiwan, particularly sensitive for detecting E. coli, S. pneumoniae, and K. pneumoniae. The assay may facilitate early diagnosis and guidance for antimicrobial therapy for adult patients with this deadly disease in Taiwan. © 2015 APMIS. Published by John Wiley & Sons Ltd.
Novel microneutralization assay for HCMV using automated data collection and analysis.
Abai, Anna Maria; Smith, Larry R; Wloch, Mary K
2007-04-30
In addition to being sensitive and specific, an assay for the assessment of neutralizing antibody activity from clinical trial samples must be amenable to automation for use in high-volume screening. To that effect, we developed a 96-well microplate assay for the measurement of HCMV-neutralizing activity in human sera using the HCMV-permissive human cell line HEL-299 and the laboratory strain of HCMV AD169. The degree to which neutralizing antibodies diminish HCMV infection of cells in the assay is determined by quantifying the nuclei of infected cells based on expression of the 72 kDa IE1 viral protein. Nuclear IE1 is visualized using a highly sensitive immunoperoxidase staining and the stained nuclei are counted using an automated ELISPOT analyzer. The use of Half Area 96-well microplates, with wells in which the surface area of the well bottom is half the area of a standard 96-well microplate plate, improves signal detection compared with standard microplates and economizes on the usage of indicator cells, virus, and reagents. The staining process was also streamlined by using a microplate washer and data analysis was simplified and accelerated by employing a software program that automatically plots neutralization curves and determines NT(50) values using 4-PL curve fitting. The optimized assay is not only fast and convenient, but also specific, sensitive, precise and reproducible and thus has the characteristics necessary for use in measuring HCMV-neutralizing activity in the sera of vaccine trial subjects such as the recipients of Vical's HCMV pDNA vaccine candidates.
CHINNAYELKA, SWETHA; McSHANE, and MICHAEL J.
2015-01-01
Fluorescent sensing systems offer the potential for noninvasive monitoring with implantable devices, but they require carrier technologies that provide suitable immobilization, accessibility, and biocompatibility while maintaining adequate response characteristics. A recent development towards this goal is a highly specific and sensitive competitive binding assay for glucose using apo-glucose oxidase (apo-GOx) as the recognition element and dextran as the competing ligand; this has been demonstrated as a glucose sensor system by encapsulating the competitive binding assay in semipermeable microcapsule carriers. This paper describes the extension of this sensor design to longer wavelengths in an attempt to increase the applicability to in vivo monitoring. The glucose sensitivity of the tetramethylrhodamine isothiocyanate-dextran (TD) and cyanine Cy5-apo-GOx (CAG) complexes showed five to 10 times greater specificity for β-D-glucose over other sugars. Microcapsules loaded with TD/CAG complexes exhibited a linear, totally reversible response in the range of 0–720 mg/dL, with a sensitivity (percent change in intensity ratio) of 0.06%/(mg/dL). The decrease in sensitivity observed with the use of longer-wavelength dyes is most likely to be compensated with the deeper penetration of light and reduced tissue scattering. These findings imply that the encapsulation of sensing assay elements in microcapsules is a simple and translatable method for the fabrication of stable biosensors, and optimization of resonance energy transfer pairs and assay component preparation will further improve the response to approach clinically relevant performance. PMID:16800748
Sriwilaijaroen, Nongluk; Kelly, Jane Xu; Riscoe, Michael; Wilairat, Prapon
2004-12-01
The appearance of drug resistant parasites and the absence of an effective vaccine have resulted in the need for new effective antimalarial drugs. Consequently, a convenient method for in vitro screening of large numbers of antimalarial drug candidates has become apparent. The CyQUANT cell proliferation assay is a highly sensitive fluorescence-based method for quantitation of cell number by measuring the strong fluorescence produced when green GR dye binds to nucleic acids. We have applied the CyQUANT assay method to evaluate the growth of Plasmodium falciparum D6 strain in culture. The GR-nucleic acid fluorescence linearly correlated with percent parasitemia at both 0.75 or 1 percent hematocrit with the same correlation coefficient of r2 = 0.99. The sensitivity of P. falciparum D6 strain to chloroquine and to 3,6-bis-omega-diethylaminoamyloxyxanthone, a novel antimalarial, determined by the CyQUANT assay were comparable to those obtained by the traditional [3H]-ethanolamine assay: IC50 value of chloroquine was 54 nM and 51 nM by the CyQUANT and [3H]-ethanolamine assay, respectively; IC50 value for 3,6-bis-omega-diethylaminoamyloxyxanthone was 254 nM and 223 nM by the CyQUANT and [3H]-ethanolamine assay, respectively. This procedure requires no radioisotope, uses simple equipment, and is an easy and convenient procedure, with no washing and harvesting steps. Moreover, all procedures can be set up continuously and thus, the CyQUANT assay is suitable in automatic high through-put drug screening of antimalarial drugs.
Wilkes, Rebecca P; Sanchez, Elena; Riley, Matthew C; Kennedy, Melissa A
2014-01-01
Canine distemper virus (CDV) remains a common cause of infectious disease in dogs, particularly in high-density housing situations such as shelters. Vaccination of all dogs against CDV is recommended at the time of admission to animal shelters and many use a modified live virus (MLV) vaccine. From a diagnostic standpoint for dogs with suspected CDV infection, this is problematic because highly sensitive diagnostic real-time reverse transcription polymerase chain reaction (RT-PCR) tests are able to detect MLV virus in clinical samples. Real-time PCR can be used to quantitate amount of virus shedding and can differentiate vaccine strains from wild-type strains when shedding is high. However, differentiation by quantitation is not possible in vaccinated animals during acute infection, when shedding is low and could be mistaken for low level vaccine virus shedding. While there are gel-based RT-PCR assays for differentiation of vaccine strains from field strains based on sequence differences, the sensitivity of these assays is unable to match that of the real-time RT-PCR assay currently used in the authors' laboratory. Therefore, a real-time RT-PCR assay was developed that detects CDV MLV vaccine strains and distinguishes them from wild-type strains based on nucleotide sequence differences, rather than the amount of viral RNA in the sample. The test is highly sensitive, with detection of as few as 5 virus genomic copies (corresponding to 10(-1) TCID(50)). Sequencing of the DNA real-time products also allows phylogenetic differentiation of the wild-type strains. This test will aid diagnosis during outbreaks of CDV in recently vaccinated animals.
Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V.; Chen, Jie; Lorey, Thomas S.; Gage, Julia C.; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M.; Castle, Philip E.
2014-01-01
Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (Ptrend < 0.001), HPV18 (Ptrend = 0.07), and other carcinogenic types (Ptrend < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. PMID:24899025
A Sensitive Luminescent Assay for the Histone Methyltransferase NSD1 and Other SAM-Dependent Enzymes
Drake, Katherine M.; Watson, Venita G.; Kisielewski, Anne; Glynn, Rebecca
2014-01-01
Abstract A major focus of our pediatric cancer research is the discovery of chemical probes to further our understanding of the biology of leukemia harboring fusion proteins arising from chromosomal rearrangements, and to develop novel specifically targeted therapies. The NUP98-NSD1 fusion protein occurs in a highly aggressive subtype of acute myeloid leukemia after rearrangement of the genes NUP98 and NSD1. The methyltransferase activity of NSD1 is retained in the fusion, and it gives rise to abnormally high levels of methylation at lysine 36 on histone 3, enforcing oncogene activation. Therefore, inhibition of the methyltransferase activity of NUP98-NSD1 may be considered a viable therapeutic strategy. Here, we report the development and validation of a highly sensitive and robust luminescence-based assay for NSD1 and other methyltransferases that use S-adenosylmethionine (SAM) as a methyl donor. The assay quantifies S-adenosylhomocysteine (SAH), which is produced during methyl transfer from SAM. SAH is converted enzymatically to adenosine monophosphate (AMP); in the process, adenosine triphosphate (ATP) is consumed and the amount of ATP remaining is measured using a luminescent assay kit. The assay was validated by pilot high-throughput screening (HTS), dose-response confirmation of hits, and elimination of artifacts through counterscreening against SAH detection in the absence of NSD1. The known methyltransferase inhibitor suramin was identified, and profiled for selectivity against the histone methyltransferases EZH2, SETD7, and PRMT1. HTS using the luminescent NSD1 assay described here has the potential to deliver selective NSD1 inhibitors that may serve as leads in the development of targeted therapies for NUP98-NSD1-driven leukemias. PMID:24927133
Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.
Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T
2018-02-01
Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.
Nagai, Takashi; Taya, Kiyoshi; Yoda, Ikuko
2016-02-01
The authors used 5 species of periphytic algae to conduct toxicity assays of 20 herbicides. The 5 tested species represent riverine primary producers most likely to be affected by herbicides. A fluorescence microplate toxicity assay was used as an efficient and economical high-throughput assay. Toxicity characteristics were analyzed, focusing on their relationship to herbicide mode of action. The relative differences between 50% and 10% effect concentrations depended on herbicide mode of action, rather than tested species. Moreover, a clear relationship between sensitive species and herbicide mode of action was also observed. Green alga was most sensitive to herbicides of 2 mode of action groups: inhibitors of protoporphyrinogen oxidase and very long-chain fatty acid synthesis. Diatoms were most sensitive to herbicides of 1 mode of action group: 4-hydroxyphenyl-pyruvate-dioxygenase inhibitors. Cyanobacterium was most sensitive to herbicides of 1 mode of action group: inhibitors of acetolactate synthase. The species sensitivity distribution based on obtained data was also analyzed. The slopes of the species sensitivity distribution significantly differed among modes of action, suggesting that difference in species sensitivity is specific to the mode of action. In particular, differences in species sensitivity were markedly large for inhibitors of acetolactate synthase, protoporphyrinogen oxidase, and very long-chain fatty acid synthesis. The results clearly showed that a single algal species cannot represent the sensitivity of an algal assemblage. Therefore, multispecies algal toxicity data are essential for substances with specific modes of action. © 2015 SETAC.
Kalinina, Marina A; Skvortsov, Dmitry A; Rubtsova, Maria P; Komarova, Ekaterina S; Dontsova, Olga A
2018-06-01
High- and medium-throughput assays are now routine methods for drug screening and toxicology investigations on mammalian cells. However, a simple and cost-effective analysis of cytotoxicity that can be carried out with commonly used laboratory equipment is still required. The developed cytotoxicity assays are based on human cell lines stably expressing eGFP, tdTomato, mCherry, or Katushka2S fluorescent proteins. Red fluorescent proteins exhibit a higher signal-to-noise ratio, due to less interference by medium autofluorescence, in comparison to green fluorescent protein. Measurements have been performed on a fluorescence scanner, a plate fluorimeter, and a camera photodocumentation system. For a 96-well plate assay, the sensitivity per well and the measurement duration were 250 cells and 15 min for the scanner, 500 cells and 2 min for the plate fluorimeter, and 1000 cells and less than 1 min for the camera detection. These sensitivities are similar to commonly used MTT (tetrazolium dye) assays. The used scanner and the camera had not been previously applied for cytotoxicity evaluation. An image processing scheme for the high-resolution scanner is proposed that significantly diminishes the number of control wells, even for a library containing fluorescent substances. The suggested cytotoxicity assay has been verified by measurements of the cytotoxicity of several well-known cytotoxic drugs and further applied to test a set of novel bacteriotoxic compounds in a medium-throughput format. The fluorescent signal of living cells is detected without disturbing them and adding any reagents, thus allowing to investigate time-dependent cytotoxicity effects on the same sample of cells. A fast, simple and cost-effective assay is suggested for cytotoxicity evaluation based on mammalian cells expressing fluorescent proteins and commonly used laboratory equipment.
Jiang, Lu Xi; Ren, Hong Yu; Zhou, Hai Jian; Zhao, Si Hong; Hou, Bo Yan; Yan, Jian Ping; Qin, Tian; Chen, Yu
2017-08-01
Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catarrhalis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebacterium diphtheriae, and Streptococcus pyogenes. Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 152 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. This study revealed that the MPCE assay is a rapid, reliable, and high-throughput method with high specificity and sensitivity. This assay has great potential in the molecular epidemiological survey of respiratory pathogens. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Simultaneous detection of ricin and abrin DNA by real-time PCR (qPCR).
Felder, Eva; Mossbrugger, Ilona; Lange, Mirko; Wölfel, Roman
2012-09-01
Ricin and abrin are two of the most potent plant toxins known and may be easily obtained in high yield from the seeds using rather simple technology. As a result, both toxins are potent and available toxins for criminal or terrorist acts. However, as the production of highly purified ricin or abrin requires sophisticated equipment and knowledge, it may be more likely that crude extracts would be used by non-governmental perpetrators. Remaining plant-specific nucleic acids in these extracts allow the application of a real-time PCR (qPCR) assay for the detection and identification of abrin or ricin genomic material. Therefore, we have developed a duplex real-time PCR assays for simultaneous detection of ricin and abrin DNA based on the OmniMix HS bead PCR reagent mixture. Novel primers and hybridization probes were designed for detection on a SmartCycler instrument by using 5'-nuclease technology. The assay was thoroughly optimized and validated in terms of analytical sensitivity. Evaluation of the assay sensitivity by probit analysis demonstrated a 95% probability of detection at 3 genomes per reaction for ricin DNA and 1.2 genomes per reaction for abrin DNA. The suitability of the assays was exemplified by detection of ricin and abrin contaminations in a food matrix.
Huang, Rong-Yuan; Chang, Hao-Teng; Lan, Chung-Yu; Pai, Tun-Wen; Wu, Chao-Nan; Ling, Chung-Mei; Chang, Margaret Dah-Tsyr
2008-08-01
A high-throughput polymerase chain reaction (PCR)-based enzyme-linked oligonucleotide-sorbent assay (ELOSA) was developed for use in the diagnostic testing of serum from patients who may be infected with different hepatitis C virus (HCV) genotypes. Twelve genotype-specific 5'-aminated DNA-coated probes were designed based on the variable 5'-untranslated region sequences of the HCV genotypes 1-6. Using 100 clinical serum samples, the performance of the PCR-ELOSA method was compared with Roche's COBAS Amplicor HCV Monitor V2.0 assay and the VERSANT HCV genotype assay (LiPA), and the overall agreement was 99% at the level of HCV genotypes with a detection range of 2.0 x 10(2) to 1.0 x 10(7)IU/ml for PCR-ELOSA. The PCR-ELOSA was more comprehensive as demonstrated by the fact that approximately 20% of the samples with different subtypes could be discriminated by this method but not by LiPA. In addition, the PCR-ELOSA system showed high accuracy (CV
Wang, Yulong; Su, Zhenhe; Wang, Limin; Dong, Jinbo; Xue, Juanjuan; Yu, Jiao; Wang, Yuan; Hua, Xiude; Wang, Minghua; Zhang, Cunzheng; Liu, Fengquan
2017-06-20
We have developed a rapid and ultrasensitive surface-enhanced Raman scattering (SERS) assay for Cu 2+ detection using the multiple antibiotic resistance regulator (MarR) as specific bridging molecules in a SERS hot-spot model. In the assay, Cu 2+ induces formation of MarR tetramers, which provide Au nanoparticle (NP)-AuNP bridges, resulting in the formation of SERS hot spots. 4-Mercaptobenzoic acid (4-MBA) was used as a Raman reporter. The addition of Cu 2+ increased the Raman intensity of 4-MBA. Use of a dual hot-spot signal-amplification strategy based on AuNP-AgNP heterodimers combined through antigen-antibody reactions increased the sensitivity of the sensing platform by 50-fold. The proposed method gave a linear response for Cu 2+ detection in the range of 0.5-1000 nM, with a detection limit of 0.18 nM, which is 5 orders of magnitude lower than the U.S. Environmental Protection Agency limit for Cu 2+ in drinking water (20 μM). In addition, all analyses can be completed in less than 15 min. The high sensitivity, high specificity, and rapid detection capacity of the SERS assay therefore provide a combined advantage over current assays.
High-Throughput Analysis of Global DNA Methylation Using Methyl-Sensitive Digestion.
Shiratori, Hiromi; Feinweber, Carmen; Knothe, Claudia; Lötsch, Jörn; Thomas, Dominique; Geisslinger, Gerd; Parnham, Michael J; Resch, Eduard
2016-01-01
DNA methylation is a major regulatory process of gene transcription, and aberrant DNA methylation is associated with various diseases including cancer. Many compounds have been reported to modify DNA methylation states. Despite increasing interest in the clinical application of drugs with epigenetic effects, and the use of diagnostic markers for genome-wide hypomethylation in cancer, large-scale screening systems to measure the effects of drugs on DNA methylation are limited. In this study, we improved the previously established fluorescence polarization-based global DNA methylation assay so that it is more suitable for application to human genomic DNA. Our methyl-sensitive fluorescence polarization (MSFP) assay was highly repeatable (inter-assay coefficient of variation = 1.5%) and accurate (r2 = 0.99). According to signal linearity, only 50-80 ng human genomic DNA per reaction was necessary for the 384-well format. MSFP is a simple, rapid approach as all biochemical reactions and final detection can be performed in one well in a 384-well plate without purification steps in less than 3.5 hours. Furthermore, we demonstrated a significant correlation between MSFP and the LINE-1 pyrosequencing assay, a widely used global DNA methylation assay. MSFP can be applied for the pre-screening of compounds that influence global DNA methylation states and also for the diagnosis of certain types of cancer.
Coakley, Eoin; Reeves, Jacqueline D.; Huang, Wei; Mangas-Ruiz, Marga; Maurer, Irma; Harskamp, Agnes M.; Gupta, Soumi; Lie, Yolanda; Petropoulos, Christos J.; Schuitemaker, Hanneke; van 't Wout, Angélique B.
2009-01-01
The recent availability of CCR5 antagonists as anti-human immunodeficiency virus (anti-HIV) therapeutics has highlighted the need to accurately identify CXCR4-using variants in patient samples when use of this new drug class is considered. The Trofile assay (Monogram Biosciences) has become the method that is the most widely used to define tropism in the clinic prior to the use of a CCR5 antagonist. By comparison, the MT-2 assay has been used since early in the HIV epidemic to define tropism in clinical specimens. Given that there are few data from direct comparisons of these two assays, we evaluated the performance of the plasma-based Trofile assay and the peripheral blood mononuclear cell (PBMC)-based MT-2 assay for the detection of CXCR4 use in defining the tropism of HIV isolates derived from clinical samples. The various samples used for this comparison were derived from participants of the Amsterdam Cohort Studies on HIV infection and AIDS who underwent consecutive MT-2 assay testing of their PBMCs at approximately 3-month intervals. This unique sample set was specifically selected because consecutive MT-2 assays had demonstrated a shift from negative to positive in PBMCs, reflecting the first emergence of CXCR4-using virus in PBMCs above the level of detection of the assay in these individuals. Trofile testing was performed with clonal HIV type 1 (HIV-1) variants (n = 21), MT-2 cell culture-derived cells (n = 20) and supernatants (n = 42), and plasma samples (n = 76). Among the clonal HIV-1 variants and MT-2 cell culture-derived samples, the results of the Trofile and MT-2 assays demonstrated a high degree of concordance (95% to 98%). Among consecutive plasma samples, detection of CXCR4-using virus was at or before the time of first detection by the MT-2 assay in 5/10 patients by the original Trofile assay and in 9/10 patients by the enhanced-sensitivity Trofile assay. Differences in the time to the first detection of CXCR4 use between the MT-2 assay (PBMCs) and the original Trofile assay (plasma) were greatly reduced by the enhanced-sensitivity Trofile assay, suggesting that sensitivity for the detection of minor CXCR4-using variants may be a more important determinant of discordant findings than compartmentalization. The similarities in performance of the enhanced-sensitivity Trofile and MT-2 assays suggest that either may be an appropriate methodology to define tropism in patient specimens. PMID:19687240
Martin, Jaclyn; Carrillo, Yisel; Talley, Justin L.; Ochoa-Corona, Francisco M.
2018-01-01
Background The importance of tick and flea-borne rickettsia infections is increasingly recognized worldwide. While increased focus has shifted in recent years to the development of point-of-care diagnostics for various vector-borne diseases in humans and animals, little research effort has been devoted to their integration into vector surveillance and control programs, particularly in resource-challenged countries. One technology which may be helpful for large scale vector surveillance initiatives is loop-mediated isothermal amplification (LAMP). The aim of this study was to develop a LAMP assay to detect spotted fever group (SFG) rickettsia DNA from field-collected ticks and fleas and compare with published end-point PCR results. Methodology/Principal findings A Spotted Fever Group rickettsia-specific loop-mediated isothermal amplification (SFGR-LAMP) assay was developed using primers based on a region of the R. rickettsii 17kDa protein gene. The sensitivity, specificity, and reproducibility of the assay were evaluated. The assay was then compared with the results of end-point PCR assays for pooled tick and flea samples obtained from field-based surveillance studies. The sensitivity of the SFGR-LAMP assay was 0.00001 ng/μl (25μl volume) which was 10 times more sensitive than the 17kDa protein gene end-point PCR used as the reference method. The assay only recognized gDNA from SFG and transitional group (TRG) rickettsia species tested but did not detect gDNA from typhus group (TG) rickettsia species or closely or distantly related bacterial species. The SFGR-LAMP assay detected the same positives from a set of pooled tick and flea samples detected by end-point PCR in addition to two pooled flea samples not detected by end-point PCR. Conclusions/significance To our knowledge, this is the first study to develop a functional LAMP assay to initially screen for SFG and TRG rickettsia pathogens in field-collected ticks and fleas. With a high sensitivity and specificity, the results indicate the potential use as a field-based surveillance tool for tick and flea-borne rickettsial pathogens in resource-challenged countries. PMID:29390021
Noden, Bruce H; Martin, Jaclyn; Carrillo, Yisel; Talley, Justin L; Ochoa-Corona, Francisco M
2018-01-01
The importance of tick and flea-borne rickettsia infections is increasingly recognized worldwide. While increased focus has shifted in recent years to the development of point-of-care diagnostics for various vector-borne diseases in humans and animals, little research effort has been devoted to their integration into vector surveillance and control programs, particularly in resource-challenged countries. One technology which may be helpful for large scale vector surveillance initiatives is loop-mediated isothermal amplification (LAMP). The aim of this study was to develop a LAMP assay to detect spotted fever group (SFG) rickettsia DNA from field-collected ticks and fleas and compare with published end-point PCR results. A Spotted Fever Group rickettsia-specific loop-mediated isothermal amplification (SFGR-LAMP) assay was developed using primers based on a region of the R. rickettsii 17kDa protein gene. The sensitivity, specificity, and reproducibility of the assay were evaluated. The assay was then compared with the results of end-point PCR assays for pooled tick and flea samples obtained from field-based surveillance studies. The sensitivity of the SFGR-LAMP assay was 0.00001 ng/μl (25μl volume) which was 10 times more sensitive than the 17kDa protein gene end-point PCR used as the reference method. The assay only recognized gDNA from SFG and transitional group (TRG) rickettsia species tested but did not detect gDNA from typhus group (TG) rickettsia species or closely or distantly related bacterial species. The SFGR-LAMP assay detected the same positives from a set of pooled tick and flea samples detected by end-point PCR in addition to two pooled flea samples not detected by end-point PCR. To our knowledge, this is the first study to develop a functional LAMP assay to initially screen for SFG and TRG rickettsia pathogens in field-collected ticks and fleas. With a high sensitivity and specificity, the results indicate the potential use as a field-based surveillance tool for tick and flea-borne rickettsial pathogens in resource-challenged countries.
Lennard, L
1987-12-25
A highly sensitive reversed-phase high-performance liquid chromatographic assay, with ultraviolet detection, for 6-thioinosinic acid and the 6-thioguanine nucleotides (6TGNs) was developed. The 6TGNs are major red blood cell metabolites of the immunosuppressive agent azathioprine and the cytotoxic drugs 6-thioguanine and 6-mercaptopurine. The assay is based on the specific extraction, via phenyl mercury adduct formation, of the thiopurine released on acid hydrolysis of the thionucleotide metabolite. Red blood cell 6TGN concentrations in eighteen leukaemic children receiving chronic 6-mercaptopurine chemotherapy were measured and compared to a previously published spectrophotofluorometric assay. Linear regression analysis gave r = 0.991; P less than 0.001; y = 40 + 0.94x.
Sanchis, Juan; Bardají, Alfredo; Bosch, Xavier; Loma-Osorio, Pablo; Marín, Francisco; Sánchez, Pedro L; Calvo, Francisco; Avanzas, Pablo; Hernández, Carolina; Serrano, Silvia; Carratalá, Arturo; Barrabés, José A
2013-07-01
High-sensitivity troponin assays have improved the diagnosis of acute coronary syndrome in patients presenting with chest pain and normal troponin levels as measured by conventional assays. Our aim was to investigate whether N-terminal pro-brain natriuretic peptide provides additional information to troponin determination in these patients. A total of 398 patients, included in the PITAGORAS study, presenting to the emergency department with chest pain and normal troponin levels as measured by conventional assay in 2 serial samples (on arrival and 6 h to 8h later) were studied. The samples were also analyzed in a central laboratory for high-sensitivity troponin T (both samples) and for N-terminal pro-brain natriuretic peptide (second sample). The endpoints were diagnosis of acute coronary syndrome and the composite endpoint of in-hospital revascularization or a 30-day cardiac event. Acute coronary syndrome was adjudicated to 79 patients (20%) and the composite endpoint to 59 (15%). When the N-terminal pro-brain natriuretic peptide quartile increased, the diagnosis of acute coronary syndrome also increased (12%, 16%, 23% and 29%; P=.01), as did the risk of the composite endpoint (6%, 13%, 16% and 24%; P=.004). N-terminal pro-brain natriuretic peptide elevation (>125ng/L) was associated with both endpoints (relative risk= 2.0; 95% confidence interval, 1.2-3.3; P=.02; relative risk=2.4; 95% confidence interval, 1.4-4.2; P=.004). However, in the multivariable models adjusted by clinical and electrocardiographic data, a predictive value was found for high-sensitivity T troponin but not for N-terminal pro-brain natriuretic peptide. In low-risk patients with chest pain of uncertain etiology evaluated using high-sensitivity T troponin, N-terminal pro-brain natriuretic peptide does not contribute additional predictive value to diagnosis or the prediction of short-term outcomes. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-09-01
We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.
Rufai, Syed Beenish; Singh, Amit; Singh, Jitendra; Kumar, Parveen; Sankar, Manimuthu Mani; Singh, Sarman
2017-08-01
Tuberculous meningitis (TBM) is the most severe form of extra-pulmonary tuberculosis (TB) due to association of diseases with high rates of mortality and morbidity. Diagnosis continues to be a clinical challenge as microbiological confirmation is rare and time consuming resulting in delayed treatment. Xpert MTB/RIF assay is a rapid and simple test, which has been endorsed by World Health Organization as an initial diagnostic test for the diagnosis of TBM. However, evidence still lacks for its performance on cerebrospinal fluid (CSF) for the diagnosis of TBM especially from India. A total of 267 CSF samples from patients with high clinico-radiological suspicion of TBM were included in this study. Ziehl-Neelsen (ZN) staining, BACTEC Mycobacterial Growth Indicator Tube (MGIT-960) culture system, and Xpert MTB/RIF assay (using cartridge version G4) were tested on all samples. Of total 267 samples, all were negative for smear AFB and 52 (19.5%) were culture positive by MGIT-960 culture system. However, out of 52 (19.5%) cultures detected positive by MGIT-960, 5 (9.6%) were detected as resistant to rifampicin. Xpert MTB/RIF assay was positive in 38 (14.2%) samples and negative in 223 (83.5%) samples. Cartridge error was detected in 6 (2.2%) samples, which could not be repeated due to insufficient sample volume. The sensitivity and specificity of Xpert MTB/RIF assay in comparison to MGIT-960 was 55.1% (95%, CI: 40.2-69.3) and 94.8% (95%, CI: 90.9-97.4) respectively. Overall, Xpert MTB/RIF assay detected 38 (14.2%) as positive for MTB of which 4 (10.5%), 31 (81.6%) and 3 (7.9%) were found to be rifampicin resistant, sensitive and indeterminate respectively. Xpert MTB/RIF assay showed lower sensitivity as compared to MGIT 960 culture for the diagnosis of TBM from CSF samples. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Reinbold, James B.; Coetzee, Johann F.; Sirigireddy, Kamesh R.; Ganta, Roman R.
2010-01-01
Insufficient diagnostic sensitivity and specificity coupled with the potential for cross-reactivity among closely related Anaplasma species has made the accurate determination of infection status problematic. A method for the development of simplex and duplex real-time quantitative reverse transcriptase PCR (qRT-PCR) assays for the detection of A. marginale and A. phagocytophilum 16S rRNA in plasma-free bovine peripheral blood samples is described. The duplex assay was able to detect as few as 100 copies of 16S rRNA of both A. marginale and A. phagocytophilum in the same reaction. The ratio of 16S rRNA to 16S DNA copies for A. marginale was determined to be 117.9:1 (95% confidence interval [95% CI], 100.7:1, 135.2:1). Therefore, the detection limit is the minimum infective unit of one A. marginale bacterium. The duplex assay detected nonequivalent molar ratios as high as 100-fold. Additionally, the duplex assay and a competitive enzyme-linked immunosorbent assay (cELISA) were used to screen 237 samples collected from herds in which anaplasmosis was endemic. When the cELISA was evaluated by the results of the qRT-PCR, its sensitivity and specificity for the detection of A. marginale infection were found to be 65.2% (95% CI, 55.3%, 75.1%) and 97.3% (95% CI, 94.7%, 99.9%), respectively. A. phagocytophilum infection was not detected in the samples analyzed. One- and two-way receiver operator characteristic curves were constructed in order to recommend the optimum negative cutoff value for the cELISA. Percentages of inhibition of 20 and 15.3% were recommended for the one- and two-way curves, respectively. In conclusion, the duplex real-time qRT-PCR assay is a highly sensitive and specific diagnostic tool for the accurate and precise detection of A. marginale and A. phagocytophilum infections in cattle. PMID:20463162
True, K.; Purcell, M.K.; Foott, J.S.
2009-01-01
Parvicapsula minibicornis is a myxosporean parasite that is associated with disease in Pacific salmon during their freshwater life history phase. This study reports the development of a quantitative (real-time) polymerase chain reaction (QPCR) to detect P. minibicornis DNA. The QPCR assay targets the 18S ribosomal subunit gene. A plasmid DNA control was developed to calibrate cycle threshold (CT) score to plasmid molecular equivalent (PME) units, a measure of gene copy number. Assay validation revealed that the QPCR was sensitive and able to detect 50 ag of plasmid DNA, which was equivalent to 12.5 PME. The QPCR assay could detect single P. minibicornis actinospores well above assay sensitivity, indicating a single spore contains at least 100 times the 18S DNA copies required for detection. The QPCR assay was repeatable and highly specific; no detectable amplification was observed using DNA from related myxozoan parasites. The method was validated using kidney tissues from 218 juvenile Chinook salmon sampled during the emigration period of March to July 2005 from the Klamath River. The QPCR assay was compared with histological examination. The QPCR assay detected P. minibicornis infection in 88.1% of the fish sampled, while histological examination detected infection in 71.1% of the fish sampled. Good concordance was found between the methods as 80% of the samples were in agreement. The majority of the disconcordant fish were positive by QPCR, with low levels of P. minibicornis DNA, but negative by histology. The majority of the fish rated histologically as having subclinical or clinical infections had high QPCR levels. The results of this study demonstrate that QPCR is a sensitive quantitative tool for evaluating P. minibicornis infection in fish health monitoring studies. ?? 2008 Blackwell Publishing Ltd.
Hamilton, Desmond J; Coffman, Matthew D; Knight, Jefferson D; Reed, Scott M
2017-09-12
Synaptotagmin (Syt) family proteins contain tandem C2 domains, C2A and C2B, which insert into anionic membranes in response to increased cytosolic Ca 2+ concentration and facilitate exocytosis in neuronal and endocrine cells. The C2A domain from Syt7 binds lipid membranes much more tightly than the corresponding domain from Syt1, but the implications of this difference for protein function are not yet clear. In particular, the ability of the isolated Syt7 C2A domain to initiate membrane apposition and/or aggregation has been previously unexplored. Here, we demonstrate that Syt7 C2A induces apposition and aggregation of liposomes using Förster resonance energy transfer (FRET) assays, dynamic light scattering, and spectroscopic techniques involving lipid-coated gold nanoparticles (LCAuNPs). Protein-membrane binding, membrane apposition, and macroscopic aggregation are three separate phenomena with distinct Ca 2+ requirements: the threshold Ca 2+ concentration for membrane binding is lowest, followed by apposition and aggregation. However, aggregation is highly sensitive to protein concentration and can occur even at submicromolar Syt7 C2A; thus, highly sensitive assays are needed for measuring apposition without complications arising from aggregation. Notably, the localized surface plasmon resonance of the LCAuNP is sensitive to ≤10 nM Syt7 C2A concentrations. Furthermore, when the LCAuNPs were added into a FRET-based liposome apposition assay, the resultant energy transfer increased; possible explanations are discussed. Overall, LCAuNP-based methods allow for highly sensitive detection of protein-induced membrane apposition under conditions that miminize large-scale aggregation.
Wang, Kun; Fan, Daoqing; Liu, Yaqing; Wang, Erkang
2015-11-15
Simple, rapid, sensitive and specific detection of cancer cells is of great importance for early and accurate cancer diagnostics and therapy. By coupling nanotechnology and dual-aptamer target binding strategies, we developed a colorimetric assay for visually detecting cancer cells with high sensitivity and specificity. The nanotechnology including high catalytic activity of PtAuNP and magnetic separation & concentration plays a vital role on the signal amplification and improvement of detection sensitivity. The color change caused by small amount of target cancer cells (10 cells/mL) can be clearly distinguished by naked eyes. The dual-aptamer target binding strategy guarantees the detection specificity that large amount of non-cancer cells and different cancer cells (10(4) cells/mL) cannot cause obvious color change. A detection limit as low as 10 cells/mL with detection linear range from 10 to 10(5) cells/mL was reached according to the experimental detections in phosphate buffer solution as well as serum sample. The developed enzyme-free and cost effective colorimetric assay is simple and no need of instrument while still provides excellent sensitivity, specificity and repeatability, having potential application on point-of-care cancer diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Mor, Orna; Gozlan, Yael; Wax, Marina; Mileguir, Fernando; Rakovsky, Avia; Noy, Bina; Mendelson, Ella; Levy, Itzchak
2015-11-01
HIV-1 RNA monitoring, both before and during antiretroviral therapy, is an integral part of HIV management worldwide. Measurements of HIV-1 viral loads are expected to assess the copy numbers of all common HIV-1 subtypes accurately and to be equally sensitive at different viral loads. In this study, we compared for the first time the performance of the NucliSens v2.0, RealTime HIV-1, Aptima HIV-1 Quant Dx, and Xpert HIV-1 viral load assays. Plasma samples (n = 404) were selected on the basis of their NucliSens v2.0 viral load results and HIV-1 subtypes. Concordance, linear regression, and Bland-Altman plots were assessed, and mixed-model analysis was utilized to compare the analytical performance of the assays for different HIV-1 subtypes and for low and high HIV-1 copy numbers. Overall, high concordance (>83.89%), high correlation values (Pearson r values of >0.89), and good agreement were observed among all assays, although the Xpert and Aptima assays, which provided the most similar outputs (estimated mean viral loads of 2.67 log copies/ml [95% confidence interval [CI], 2.50 to 2.84 log copies/ml] and 2.68 log copies/ml [95% CI, 2.49 to 2.86 log copies/ml], respectively), correlated best with the RealTime assay (89.8% concordance, with Pearson r values of 0.97 to 0.98). These three assays exhibited greater precision than the NucliSens v2.0 assay. All assays were equally sensitive for subtype B and AG/G samples and for samples with viral loads of 1.60 to 3.00 log copies/ml. The NucliSens v2.0 assay underestimated A1 samples and those with viral loads of >3.00 log copies/ml. The RealTime assay tended to underquantify subtype C (compared to the Xpert and Aptima assays) and subtype A1 samples. The Xpert and Aptima assays were equally efficient for detection of all subtypes and viral loads, which renders these new assays most suitable for clinical HIV laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Basic design of MRM assays for peptide quantification.
James, Andrew; Jorgensen, Claus
2010-01-01
With the recent availability and accessibility of mass spectrometry for basic and clinical research, the requirement for stable, sensitive, and reproducible assays to specifically detect proteins of interest has increased. Multiple reaction monitoring (MRM) or selective reaction monitoring (SRM) is a highly selective, sensitive, and robust assay to monitor the presence and amount of biomolecules. Until recently, MRM was typically used for the detection of drugs and other biomolecules from body fluids. With increased focus on biomarkers and systems biology approaches, researchers in the proteomics field have taken advantage of this approach. In this chapter, we will introduce the reader to the basic principle of designing and optimizing an MRM workflow. We provide examples of MRM workflows for standard proteomic samples and provide suggestions for the reader who is interested in using MRM for quantification.
Tiny Grains Give Huge Gains: Nanocrystal–Based Signal Amplification for Biomolecule Detection
Tong, Sheng; Ren, Binbin; Zheng, Zhilan; Shen, Han; Bao, Gang
2013-01-01
Nanocrystals, despite their tiny sizes, contain thousands to millions of atoms. Here we show that the large number of atoms packed in each metallic nanocrystal can provide a huge gain in signal amplification for biomolecule detection. We have devised a highly sensitive, linear amplification scheme by integrating the dissolution of bound nanocrystals and metal-induced stoichiometric chromogenesis, and demonstrated that signal amplification is fully defined by the size and atom density of nanocrystals, which can be optimized through well-controlled nanocrystal synthesis. Further, the rich library of chromogenic reactions allows implementation of this scheme in various assay formats, as demonstrated by the iron oxide nanoparticle linked immunosorbent assay (ILISA) and blotting assay developed in this study. Our results indicate that, owing to the inherent simplicity, high sensitivity and repeatability, the nanocrystal based amplification scheme can significantly improve biomolecule quantification in both laboratory research and clinical diagnostics. This novel method adds a new dimension to current nanoparticle-based bioassays. PMID:23659350
Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A
2014-01-01
Background Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Results Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. Conclusion A robust and sensitive LC–MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials. PMID:24256358
Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A
2013-11-01
Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. A robust and sensitive LC-MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials.
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-02-01
We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.
Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.
2004-01-01
Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275
Ferreira, Fernanda Teixeira; Fidelis, Thiago André; Pereira, Thiago Almeida; Otoni, Alba; Queiroz, Leonardo Campos; Amâncio, Frederico Figueiredo; Antunes, Carlos Maurício; Lambertucci, José Roberto
2017-01-01
The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.
Sample-ready multiplex qPCR assay for detection of malaria
2014-01-01
Background Microscopy and antigen detecting rapid diagnostic tests are the diagnostic tests of choice in management of clinical malaria. However, due to their limitations, the need to utilize more sensitive methods such as real-time PCR (qPCR) is evident as more studies are now utilizing molecular methods in detection of malaria. Some of the challenges that continue to limit the widespread utilization of qPCR include lack of assay standardization, assay variability, risk of contamination, and the need for cold-chain. Lyophilization of molecular assays can overcome some of these limitations and potentially enable widespread qPCR utilization. Methods A recently published multiplex malaria qPCR assay was lyophilized by freezing drying into Sample-Ready™ format (MMSR). MMSR assay contained all the required reagents for qPCR including primers and probes, requiring only the addition of water and sample to perform qPCR. The performance of the MMSR assay was compared to the non-freeze dried, “wet” assay. Stability studies were done by maintaining the MMSR assays at four different ambient temperatures of 4°C, room temperature (RT), 37°C and 42°C over a period of 42 days, tested at seven-day intervals. Plasmodium falciparum and Plasmodium vivax DNAs were used for analysis of the MMSR assay either as single or mixed parasites, at two different concentrations. The CT values and the standard deviations (SD) were used in the analysis of the assay performance. Results The limit of detection for the MMSR assay was 0.244 parasites/μL for Plasmodium spp. (PLU) and P. falciparum (FAL) assay targets compared to “wet” assay which was 0.39 and 3.13 parasites/μL for PLU and FAL assay targets, respectively. The MMSR assay performed with high efficiencies similar to those of the “wet” assay and was stable at 37°C for 42 days, with estimated shelf-life of 5 months. When used to analyse field clinical samples, MMSR assay performed with 100% sensitivity and specificity compared to the “wet” assay. Conclusion The MMSR assay has the same robust performance characteristics as the “wet” assay and is highly stable. Availability of MMSR assay allows flexibility and provides an option in choosing assay for malaria diagnostics depending on the application, needs and budget. PMID:24767409
Sample-ready multiplex qPCR assay for detection of malaria.
Kamau, Edwin; Alemayehu, Saba; Feghali, Karla C; Juma, Dennis W; Blackstone, George M; Marion, William R; Obare, Peter; Ogutu, Bernhards; Ockenhouse, Christian F
2014-04-25
Microscopy and antigen detecting rapid diagnostic tests are the diagnostic tests of choice in management of clinical malaria. However, due to their limitations, the need to utilize more sensitive methods such as real-time PCR (qPCR) is evident as more studies are now utilizing molecular methods in detection of malaria. Some of the challenges that continue to limit the widespread utilization of qPCR include lack of assay standardization, assay variability, risk of contamination, and the need for cold-chain. Lyophilization of molecular assays can overcome some of these limitations and potentially enable widespread qPCR utilization. A recently published multiplex malaria qPCR assay was lyophilized by freezing drying into Sample-Ready™ format (MMSR). MMSR assay contained all the required reagents for qPCR including primers and probes, requiring only the addition of water and sample to perform qPCR. The performance of the MMSR assay was compared to the non-freeze dried, "wet" assay. Stability studies were done by maintaining the MMSR assays at four different ambient temperatures of 4°C, room temperature (RT), 37°C and 42°C over a period of 42 days, tested at seven-day intervals. Plasmodium falciparum and Plasmodium vivax DNAs were used for analysis of the MMSR assay either as single or mixed parasites, at two different concentrations. The CT values and the standard deviations (SD) were used in the analysis of the assay performance. The limit of detection for the MMSR assay was 0.244 parasites/μL for Plasmodium spp. (PLU) and P. falciparum (FAL) assay targets compared to "wet" assay which was 0.39 and 3.13 parasites/μL for PLU and FAL assay targets, respectively. The MMSR assay performed with high efficiencies similar to those of the "wet" assay and was stable at 37°C for 42 days, with estimated shelf-life of 5 months. When used to analyse field clinical samples, MMSR assay performed with 100% sensitivity and specificity compared to the "wet" assay. The MMSR assay has the same robust performance characteristics as the "wet" assay and is highly stable. Availability of MMSR assay allows flexibility and provides an option in choosing assay for malaria diagnostics depending on the application, needs and budget.
Construction of helper plasmid-mediated dual-display phage for autoantibody screening in serum.
Rajaram, Kaushik; Vermeeren, Veronique; Somers, Klaartje; Somers, Veerle; Michiels, Luc
2014-01-01
M13 filamentous bacteriophage has been used in displaying disease-specific antibodies, biomarkers, and peptides. One of the major drawbacks of using phage in diagnostic assays is the aspecific adsorption of proteins leading to a high background signal and decreasing sensitivity. To deal with this, we developed a genetically pure, exchangeable dual-display phage system in which biomarkers and streptavidin-binding protein (SBP) are displayed at opposite ends of the phage. This approach allows for sample purification, using streptavidin-coated magnetic beads resulting in a higher sensitivity of signal detection assays. Our dual-display cassette system approach also allows for easy exchange of both the anchor protein (SBP) and the displayed biomarker. The presented principle is applied for the detection of antibody reactivity against UH-RA.21 which is a good candidate biomarker for rheumatoid arthritis (RA). The applicability of dual-display phage preparation using a helper plasmid system is demonstrated, and its increased sensitivity in phage ELISA assays using patient serum samples is shown.
Identification of low level gamma-irradiation of meats by high sensitivity comet assay
NASA Astrophysics Data System (ADS)
Miyahara, Makoto; Saito, Akiko; Ito, Hitoshi; Toyoda, Masatake
2002-03-01
The detection of low levels of irradiation in meats (pork, beef, and chicken) using the new comet assay was investigated in order to assess the capability of the procedure. The new assay includes a process that improves its sensitivity to irradiation and a novel evaluation system for each slide (influence score and comet-type distribution). Samples used were purchased at retailers and were irradiated at 0.5 and 2kGy at 0°C. The samples were processed to obtain comets. Slides were evaluated by typing comets, calculating the influence score and analyzing the comet-type distribution chart of shown on the slide. Influence scores of beef, pork, and chicken at 0kGy were 287(SD=8.0), 305 (SD=12.9), and 320 (SD=21.0), respectively. Those at 500Gy, were 305 (SD=5.3), 347 (SD=10.6), and 364 (12.6), respectively. Irradiation levels in food were successfully determined. Sensitivity to irradiation differed among samples (chicken>pork>beef).
Caughey, Byron; Orru, Christina D; Groveman, Bradley R; Hughson, Andrew G; Manca, Matteo; Raymond, Lynne D; Raymond, Gregory J; Race, Brent; Saijo, Eri; Kraus, Allison
2017-01-01
Among the most sensitive, specific and practical of methods for detecting prions are the real-time quaking-induced conversion (RT-QuIC) assays. These assays exploit the fundamental self-propagating activity of prions to amplify the presence of prion seeds by as much as a trillion-fold. The reactions can detect most of the known mammalian prion diseases, often with sensitivities greater than those of animal bioassays. RT-QuIC assays are performed in multiwell plates with fluorescence detection and have now reached the sensitivity and practicality required for routine prion disease diagnostics. Some key strains of prions within particular host species, e.g., humans, cattle, and sheep, can be discriminated by comparison of RT-QuIC responses with different recombinant prion protein substrates. The most thoroughly validated diagnostic application of RT-QuIC is in the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD) using cerebrospinal fluid. Diagnostic sensitivities as high as 96% can be achieved in less than 24h with specificities of 98%-100%. The ability, if needed, to also test nasal swab samples can increase the RT-QuIC sensitivity for sCJD to virtually 100%. In addition to diagnostic applications, RT-QuIC has also been used in the testing of prion disinfectants and potential therapeutics. Mechanistically related assays are also now being developed for other protein misfolding diseases. © 2017 Elsevier Inc. All rights reserved.
Kelaher, Amy
2006-01-01
Invasive aspergillosis (IA) is a serious cause of morbidity and mortality among immunocompromised patients. Prompt and non-invasive methods for diagnosing IA are needed to improve the management of this life-threatening infection in patients with hematological disorders. In summary, this retrospective review of studies performed on the two assays finds that both assays have high sensitivity and specificity but are more useful when used together as a diagnostic strategy for patients with invasive aspergillosis.
Mustafa, Ahmad; Karmali, Amin; Abdelmoez, Wael
2016-01-01
The present work involves a sensitive high-throughput microtiter plate based colorimetric assay for estimating lipase activity using cupric acetate pyridine reagent (CAPR). In the first approach, three factors two levels factorial design methodology was used to evaluate the interactive effect of different parameters on the sensitivity of the assay method. The optimization study revealed that the optimum CAPR concentration was 7.5% w/v, the optimum solvent was heptane and the optimum CAPR pH was 6. In the second approach, the optimized colorimetric microplate assay was used to measure lipase activity based on enzymatic hydrolysis of olive oil emulsion substrate at 37°C and 150 rpm. The emulsion substrates were formulated by using olive oil, triton X-100 (10% v/v in pH 8) and sodium phosphate buffer of pH 8 in ratio of 1:1:1 in the case of Candida sp. lipase. While in the case of immobilized lipozyme RMIM, The emulsion substrates were formulated by using olive oil, triton X-100 (1% v/v in pH 8) and sodium phosphate buffer of pH 8 in ratio of 2:1:1. Absorbance was measured at 655 nm. The stability of this assay (in terms of colored heptane phase absorbance readings) retained more than 92.5% after 24 h at 4°C compared to the absorbance readings measured at zero time. In comparison with other lipase assay methods, beside the developed sensitivity, the reproducibility and the lower limit of detection (LOD) of the proposed method, it permits analyzing of 96 samples at one time in a 96-well microplate. Furthermore, it consumes small quantities of chemicals and unit operations.
Li, Min; Li, Peiwu; Wu, Hui; Zhang, Qi; Ma, Fei; Zhang, Zhaowei; Ding, Xiaoxia; Wang, Hengling
2014-01-01
Sterigmatocystin (STG), a biosynthesis precursor of aflatoxin B1, is well known for its toxic and carcinogenic effects in humans and animals. STG derivatives and protein conjugates are needed for generation of monoclonal antibodies (mAbs). This work describes a reliable and fast synthesis of novel STG derivatives, based on which novel STG bovine serum albumin conjugates were prepared. With the novel STG bovine serum albumin conjugates, three sensitive and specific mAbs against STG, named VerA 3, VerA 4, and VerA 6, were prepared by semi-solid hypoxanthine/aminopterin/thymidine (HAT) medium using a modified two-step screening procedure. They exhibited high affinity for STG and no cross-reactivity (CR) with aflatoxins B1, B2, G1, G2, and M1. Based on the most sensitive antibody VerA 3, an ultra-sensitive competitive enzyme-linked immunosorbent assay (ELISA) was developed for STG in wheat, maize, and peanuts. Assays were performed in the STG-GA-BSA-coated (0.5 µg·mL−1) ELISA format, in which the antibody was diluted to 1∶80,000. Several physicochemical factors influencing assay performance, such as pH, ionic strength, blocking solution, and diluting solution, were optimized. The final results showed that the assays had the detection limits of 0.08 ng·g−1 for wheat, 0.06 ng·g−1 for maize, and 0.1 ng·g−1 for peanuts, inter-assay and intra-assay variations of less than 10%, and recoveries ranging from 83% to 110%. These recoveries were in good agreement with those obtained by using HPLC-MS/MS method (90–104%), indicating the importance of the mAb VerA 3 in the study of STG in crude agricultural products. PMID:25184275
Kurosaki, Yohei; Okada, Sayaka; Nakamae, Sayuri; Yasuda, Jiro
2016-12-01
Bovine papular stomatitis virus (BPSV) causes pustular cutaneous disease in cattle worldwide. This paper describes the development of a specific loop-mediated isothermal amplification (LAMP) assay to detect BPSV which did not cross-react with other parapoxviruses. To assess analytical sensitivity of this LAMP assay, DNA was extracted from serially diluted BPSV from which the infectious titer was determined by a novel assay based on calf kidney epithelial cells. The LAMP assay had equivalent analytical sensitivity to quantitative PCR, and could detect as few as 86 copies of viral DNA per reaction. These results suggest that the assay is a specific and sensitive technique to rapidly diagnose bovine papular stomatitis in domestic animals. Copyright © 2016 Elsevier B.V. All rights reserved.
Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Xuejiang; Tang, Keqi
Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers wouldmore » ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.« less
Determination of boldine in plasma by high-performance liquid chromatography.
Speisky, H; Cassels, B K; Nieto, S; Valenzuela, A; Nuñez-Vergara, L J
1993-02-26
A sensitive method for the determination of boldine in blood plasma is described. The procedure involves a direct pH-buffered chloroform extraction of boldine from blood plasma, followed by its assay under isocratic conditions by HPLC with UV detection. The extraction recovery is excellent, and sensitivity and precision of the method are very high, when applied to plasma samples containing pharmacologically relevant concentrations of boldine.
Babafemi, Emmanuel O; Cherian, Benny P; Banting, Lee; Mills, Graham A; Ngianga, Kandala
2017-10-25
Rapid and accurate diagnosis of tuberculosis (TB) is key to manage the disease and to control and prevent its transmission. Many established diagnostic methods suffer from low sensitivity or delay of timely results and are inadequate for rapid detection of Mycobacterium tuberculosis (MTB) in pulmonary and extra-pulmonary clinical samples. This study examined whether a real-time polymerase chain reaction (RT-PCR) assay, with a turn-a-round time of 2 h, would prove effective for routine detection of MTB by clinical microbiology laboratories. A systematic literature search was performed for publications in any language on the detection of MTB in pathological samples by RT-PCR assay. The following sources were used MEDLINE via PubMed, EMBASE, BIOSIS Citation Index, Web of Science, SCOPUS, ISI Web of Knowledge and Cochrane Infectious Diseases Group Specialised Register, grey literature, World Health Organization and Centres for Disease Control and Prevention websites. Forty-six studies met set inclusion criteria. Generated pooled summary estimates (95% CIs) were calculated for overall accuracy and bivariate meta-regression model was used for meta-analysis. Summary estimates for pulmonary TB (31 studies) were as follows: sensitivity 0.82 (95% CI 0.81-0.83), specificity 0.99 (95% CI 0.99-0.99), positive likelihood ratio 43.00 (28.23-64.81), negative likelihood ratio 0.16 (0.12-0.20), diagnostic odds ratio 324.26 (95% CI 189.08-556.09) and area under curve 0.99. Summary estimates for extra-pulmonary TB (25 studies) were as follows: sensitivity 0.70 (95% CI 0.67-0.72), specificity 0.99 (95% CI 0.99-0.99), positive likelihood ratio 29.82 (17.86-49.78), negative likelihood ratio 0.33 (0.26-0.42), diagnostic odds ratio 125.20 (95% CI 65.75-238.36) and area under curve 0.96. RT-PCR assay demonstrated a high degree of sensitivity for pulmonary TB and good sensitivity for extra-pulmonary TB. It indicated a high degree of specificity for ruling in TB infection from sampling regimes. This was acceptable, but may better as a rule out add-on diagnostic test. RT-PCR assays demonstrate both a high degree of sensitivity in pulmonary samples and rapidity of detection of TB which is an important factor in achieving effective global control and for patient management in terms of initiating early and appropriate anti-tubercular therapy. PROSPERO CRD42015027534 .
Dharan, Nila J; Blakemore, Robert; Sloutsky, Alex; Kaur, Devinder; Alexander, Richard C; Ghajar, Minoo; Musser, Kimberlee A; Escuyer, Vincent E; Rowlinson, Marie-Claire; Crowe, Susanne; Laniado-Laborin, Rafael; Valli, Eloise; Nabeta, Pamela; Johnson, Pamela; Alland, David
2016-12-20
The Xpert ® MTB/RIF (Xpert) assay is a rapid PCR-based assay for the detection of Mycobacterium tuberculosis complex DNA (MTBc) and mutations associated with rifampin resistance (RIF). An updated version introduced in 2011, the G4 Xpert, included modifications to probe B and updated analytic software. An analytical study was performed to assess Xpert detection of mutations associated with rifampin resistance in rifampin-susceptible and -resistant isolates. A clinical study was performed in which specimens from US and non-US persons suspected of tuberculosis (TB) were tested to determine Xpert performance characteristics. All specimens underwent smear microscopy, mycobacterial culture, conventional drug-susceptibility testing and Xpert testing; DNA from isolates with discordant rifampin resistance results was sequenced. Among 191 laboratory-prepared isolates in the analytical study, Xpert sensitivity for detection of rifampin resistance associated mutations was 97.7% and specificity was 90.8%, which increased to 99.0% after DNA sequencing analysis of the discordant samples. Of the 1,096 subjects in the four clinical studies, 49% were from the US. Overall, Xpert detected MTBc in 439 of 468 culture-positive specimens for a sensitivity of 93.8% (95% confidence interval [CI]: 91.2%-95.7%) and did not detect MTBc in 620 of 628 culture-negative specimens for a specificity of 98.7% (95% CI: 97.5%-99.4%). Sensitivity was 99.7% among smear-positive cases, and 76.1% among smear-negative cases. Non-determinate MTBc detection and false-positive RIF resistance results were low (1.2 and 0.9%, respectively). The updated Xpert assay retained the high sensitivity and specificity of the previous assay versions and demonstrated low rates of non-determinate and RIF resistance false positive results.
Mertens, Marc; Vatansever, Zati; Mrenoshki, Slavcho; Krstevski, Kiril; Stefanovska, Jovana; Djadjovski, Igor; Cvetkovikj, Iskra; Farkas, Robert; Schuster, Isolde; Donnet, Fabien; Comtet, Loic; Tordo, Noël; Ben Mechlia, Mohamed; Balkema-Buschmann, Anne; Mitrov, Dine; Groschup, Martin H.
2015-01-01
Background There are only few assays available for the detection of Crimean-Congo Hemorrhagic Fever Virus (CCHFV)-specific antibodies in animals, and data about diagnostic sensitivity and specificity are incompletely documented for most of these tests. This is unfortunate since CCHFV antibodies in animals can be used as indicator for virus circulation in a geographic area and therewith potential risk of human exposure. This paper therefore reports on a novel ELISA for the detection of CCHFV-specific antibodies in cattle and on its application for testing ruminant sera from the Former Yugoslav Republic of Macedonia. Principal Findings A highly sensitive and specific ELISA was developed to detect CCHFV-specific IgG antibodies in cattle. The assay was validated by using 503 negative serum samples from a country where CCHFV has never been detected until now, and by using 54 positive serum samples. The positive sera were verified by using two commercially available assays (for testing human serum) which we have adapted for use in animals. The sensitivity of the novel ELISA was 98% and its specificity 99%. The presence of Hyalomma ticks was demonstrated in the Former Yugoslav Republic of Macedonia and depending on the region antibody prevalence rates up to 80% were detected in the cattle population. Conclusion This article describes a fully validated, highly sensitive and specific ELISA for the detection of CCHFV-specific IgG antibodies in cattle. Using this assay, CCHFV-specific antibodies were detected for the first time in cattle in the Former Yugoslav Republic of Macedonia, giving evidence for an active circulation of this virus in the country. Supporting this conclusion, the occurrence of the main vector of CCHFV was demonstrated in the present work for the first time in Former Yugoslav Republic of Macedonia. PMID:25742017
Wang, Dan; Xie, Jiangbi; Zhu, Xiaocui; Li, Jinqiu; Zhao, Dongqin; Zhao, Meiping
2014-05-15
In this work, we demonstrate a novel estrogenic receptor fragment-based homogeneous fluorescent assay which enables rapid and sensitive detection of 17β-estradiol (E2) and other highly potent estrogens. A modified human estrogenic receptor fragment (N-His × 6-hER270-595-C-Strep tag II) has been constructed that contains amino acids 270-595 of wild-type human estrogenic receptor α (hER270-595) and two specific tags (6 × His and Strep tag II) fused to the N and C terminus, respectively. The designed receptor protein fragment could be easily produced by prokaryotic expression with high yield and high purity. The obtained protein exhibits high binding affinity to E2 and the two tags greatly facilitate the application of the recombinant protein. Taking advantage of the unique spectroscopic properties of coumestrol (CS), a fluorescent phytoestrogen, a CS/hER270-595-based fluorescent assay has been developed which can sensitively respond to E2 within 1.0 min with a linear working range from 0.1 to 20 ng/mL and a limit of detection of 0.1 ng/mL. The assay was successfully applied for rapid detection of E2 in the culture medium of rat hippocampal neurons. The method also holds great potential for high-throughput monitoring the variation of estrogen levels in complex biological fluids, which is crucial for investigation of the molecular basis of various estrogen-involved processes. Copyright © 2013 Elsevier B.V. All rights reserved.
Nagpal, Ravinder; Ogata, Kiyohito; Tsuji, Hirokazu; Matsuda, Kazunori; Takahashi, Takuya; Nomoto, Koji; Suzuki, Yoshio; Kawashima, Kazunari; Nagata, Satoru; Yamashiro, Yuichiro
2015-10-19
Clostridium perfringens is a widespread pathogen, but the precise quantification of this subdominant gut microbe remains difficult due to its low fecal count (particularly in asymptomatic subjects) and also due to the presence of abundant polymerase-inhibitory substances in human feces. Also, information on the intestinal carriage of toxigenic C. perfringens strains in healthy subjects is sparse. Therefore, we developed a sensitive quantitative real-time PCR assays for quantification of C. perfringens in human feces by targeting its α-toxin and enterotoxin genes. To validate the assays, we finally observed the occurrence of α-toxigenic and enterotoxigenic C. perfringens in the fecal microbiota of healthy Japanese infants and young adults. The plc-specific qPCR assay was newly validated, while primers for 16S rRNA and cpe genes were retrieved from literature. The assays were validated for specificity and sensitivity in pre-inoculated fecal samples, and were finally applied to quantify C. perfringens in stool samples from apparently healthy infants (n 124) and young adults (n 221). The qPCR assays were highly specific and sensitive, with a minimum detection limit of 10(3) bacterial cells/g feces. Alpha-toxigenic C. perfringens was detected in 36% infants and 33% adults, with counts ranging widely (10(3)-10(7) bacterial cells/g). Intriguingly, the mean count of α-toxigenic C. perfringens was significantly higher in infants (6.0±1.5 log10 bacterial cells/g), as compared to that in adults (4.8±1.2). Moreover, the prevalence of enterotoxigenic C. perfringens was also found to be significantly higher in infants, as compared to that in adults. The mean enterotoxigenic C. perfringens count was 5.9±1.9 and 4.8±0.8 log10 bacterial cells/g in infants and adults, respectively. These data indicate that some healthy infants and young adults carry α-toxigenic and enterotoxigenic C. perfringens at significant levels, and may be predisposed to related diseases. Thus, high fecal carriage of toxigenic C. perfringens in healthy children warrants further investigation on its potential sources and clinical significance in these subjects. In summary, we present a novel qPCR assay for sensitive and accurate quantification of α-toxigenic and enterotoxigenic C. perfringens in human feces, which should facilitate prospective studies of the gut microbiota.
Mashooq, Mohmad; Kumar, Deepak; Niranjan, Ankush Kiran; Agarwal, Rajesh Kumar; Rathore, Rajesh
2016-07-01
A one step, single tube, accelerated probe based real time loop mediated isothermal amplification (RT LAMP) assay was developed for detecting the invasion gene (InvA) of Salmonella. The probe based RT LAMP is a novel method of gene amplification that amplifies nucleic acid with high specificity and rapidity under isothermal conditions with a set of six primers. The whole procedure is very simple and rapid, and amplification can be obtained in 20min. Detection of gene amplification was accomplished by amplification curve, turbidity and addition of DNA binding dye at the end of the reaction results in colour difference and can be visualized under normal day light and in UV. The sensitivity of developed assay was found 10 fold higher than taqman based qPCR. The specificity of the RT LAMP assay was validated by the absence of any cross reaction with other members of enterobacteriaceae family and other gram negative bacteria. These results indicate that the probe based RT LAMP assay is extremely rapid, cost effective, highly specific and sensitivity and has potential usefulness for rapid Salmonella surveillance. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Castle, Philip E; Smith, Katherine M; Davis, Thomas E; Schmeler, Kathleen M; Ferris, Daron G; Savage, Ashlyn H; Gray, Jermaine E; Stoler, Mark H; Wright, Thomas C; Ferenczy, Alex; Einstein, Mark H
2015-01-01
The Xpert HPV Assay (Xpert; Cepheid, Sunnyvale, CA) was developed for the multianalytic GeneXpert platform. In a colposcopy referral population of 708 women living in the United States, two cervical specimens, A and B, were collected, and both were tested by the Xpert assay for high-risk human papillomavirus (hrHPV) DNA, permitting an evaluation of its test reliability. Specimen B was also tested by Hybrid Capture 2 (hc2; Qiagen, Germantown, MD) and the cobas HPV Test (cobas; Roche Molecular Systems, Pleasanton, CA). The κ and percent agreement for any hrHPV for the two Xpert results were 0.88 and 94.5%, respectively. There was no statistical difference in testing positive on both specimens by Xpert (P = .62). The sensitivity for detection of cervical intraepithelial neoplasia grade 2 or more severe (CIN2+) was 89.0% using specimen A and 90.4% using specimen B for Xpert, 90.4% for cobas, and 81.6% for hc2. The Xpert assay was sensitive and reliable for the detection of hrHPV and the identification of women with CIN2+. Copyright© by the American Society for Clinical Pathology.
Steele, J C P; Phelps, R J; Simmonds, M S J; Warhurst, D C; Meyer, D J
2002-07-01
Forty-two compounds isolated from nine plants used within South America for the treatment of malaria were tested for haemin binding using two novel, rapid screening methods. The data obtained were analysed with respect to IC(50) values for in vitro toxicity to Plasmodium falciparum trophozoites. One method, a multiwell assay based on the inhibition of the interaction of haemin with glutathione (GSH), is sensitive in the 10 microM range, takes c. 1 h and is suitable for either a high throughput screen or rapid assay during natural product isolation. Of 19 compounds showing antiplasmodial activity (IC(50) < 40 microM), 16 (84%) showed >40% inhibition of GSH-haemin reaction. The sensitivity and specificity of the assay were 0.85 and 0.82, respectively. The positive predictive value was 0.81 and the negative predictive value 0.86. A more sensitive assay (0.1 microM range) is based on the reversal by haemin-binding compounds of the haemin inhibition of the L-dopachrome-methyl ester tautomerase activity of human macrophage migration inhibitory factor. This assay gives a better idea of the affinity of interaction and uses very small amounts of test compound. The log[RI(50)] of eight of the compounds that tested positive in the above assays together with those of quinine and chloroquine showed a positive correlation with log[antiplasmodial IC(50)] for strain T9-96 (r = 0.824) and strain K1 (r = 0.904). Several of the antimalarial compounds that bind haemin are isoquinolines, a class not shown previously to interact with haemin.
Kuster, Nils; Cristol, Jean-Paul; Cavalier, Etienne; Bargnoux, Anne-Sophie; Halimi, Jean-Michel; Froissart, Marc; Piéroni, Laurence; Delanaye, Pierre
2014-01-20
The National Kidney Disease Education Program group demonstrated that MDRD equation is sensitive to creatinine measurement error, particularly at higher glomerular filtration rates. Thus, MDRD-based eGFR above 60 mL/min/1.73 m² should not be reported numerically. However, little is known about the impact of analytical error on CKD-EPI-based estimates. This study aimed at assessing the impact of analytical characteristics (bias and imprecision) of 12 enzymatic and 4 compensated Jaffe previously characterized creatinine assays on MDRD and CKD-EPI eGFR. In a simulation study, the impact of analytical error was assessed on a hospital population of 24084 patients. Ability using each assay to correctly classify patients according to chronic kidney disease (CKD) stages was evaluated. For eGFR between 60 and 90 mL/min/1.73 m², both equations were sensitive to analytical error. Compensated Jaffe assays displayed high bias in this range and led to poorer sensitivity/specificity for classification according to CKD stages than enzymatic assays. As compared to MDRD equation, CKD-EPI equation decreases impact of analytical error in creatinine measurement above 90 mL/min/1.73 m². Compensated Jaffe creatinine assays lead to important errors in eGFR and should be avoided. Accurate enzymatic assays allow estimation of eGFR until 90 mL/min/1.73 m² with MDRD and 120 mL/min/1.73 m² with CKD-EPI equation. Copyright © 2013 Elsevier B.V. All rights reserved.
Das, Amaresh; Deng, Ming Y; Babiuk, Shawn; McIntosh, Michael T
2017-05-01
Capripoxviruses (CaPVs), consisting of Sheeppox virus (SPV), Goatpox virus (GPV), and Lumpy skin disease virus (LSDV) species, cause economically significant diseases in sheep, goats, and cattle, respectively. Quantitative real-time polymerase chain reaction (qPCR) assays are routinely used for rapid detection of CaPVs in surveillance and outbreak management programs. We further modified and optimized 2 previously published CaPV qPCR assays, referred to as the Balinsky and Bowden assays, by changing commercial PCR reagents used in the tests. The modified assays displayed 100% analytical specificity and showed no apparent changes in analytical sensitivities for detection of CaPVs compared with the original assays. Diagnostic sensitivities, assessed using 50 clinical reference samples from experimentally infected sheep, goats, and cattle, improved from 82% to 92% for the modified Balinsky assay and from 58% to 82% for the modified Bowden assay. The modified qPCR assays were multiplexed for detection of beta-actin as an indicator for potential false-negative results. The multiplex modified qPCR assays exhibited the same diagnostic sensitivities as the singleplex assays suggesting their utility in the detection of CaPVs.
Automatic detection of DNA double strand breaks after irradiation using an γH2AX assay.
Hohmann, Tim; Kessler, Jacqueline; Grabiec, Urszula; Bache, Matthias; Vordermark, Dyrk; Dehghani, Faramarz
2018-05-01
Radiation therapy belongs to the most common approaches for cancer therapy leading amongst others to DNA damage like double strand breaks (DSB). DSB can be used as a marker for the effect of radiation on cells. For visualization and assessing the extent of DNA damage the γH2AX foci assay is frequently used. The analysis of the γH2AX foci assay remains complicated as the number of γH2AX foci has to be counted. The quantification is mostly done manually, being time consuming and leading to person-dependent variations. Therefore, we present a method to automatically analyze the number of foci inside nuclei, facilitating and quickening the analysis of DSBs with high reliability in fluorescent images. First nuclei were detected in fluorescent images. Afterwards, the nuclei were analyzed independently from each other with a local thresholding algorithm. This approach allowed accounting for different levels of noise and detection of the foci inside the respective nucleus, using Hough transformation searching for circles. The presented algorithm was able to correctly classify most foci in cases of "high" and "average" image quality (sensitivity>0.8) with a low rate of false positive detections (positive predictive value (PPV)>0.98). In cases of "low" image quality the approach had a decreased sensitivity (0.7-0.9), depending on the manual control counter. The PPV remained high (PPV>0.91). Compared to other automatic approaches the presented algorithm had a higher sensitivity and PPV. The used automatic foci detection algorithm was capable of detecting foci with high sensitivity and PPV. Thus it can be used for automatic analysis of images of varying quality.
Li, Haiyin; Chang, Jiafu; Hou, Ting; Ge, Lei; Li, Feng
2016-11-01
Reliable, selective and sensitive approaches for trinitrophenol (TNP) detection are highly desirable with respect to national security and environmental protection. Herein, a simple and novel fluorescent strategy for highly sensitive and specific TNP assay has been successfully developed, which is based on the quenching of the fluorescent poly(thymine)-templated copper nanoclusters (DNA-CuNCs), through the synergetic effects of acid induction and electron transfer. Upon the addition of TNP, donor-acceptor complexes between the electron-deficient nitro-groups in TNP and the electron-donating DNA templates are formed, resulting in the close proximity between TNP and CuNCs. Moreover, the acidity of TNP contributes to the pH decrease of the system. These factors combine to dramatically quench the fluorescence of DNA-CuNCs, providing a "signal-off" strategy for TNP sensing. The as-proposed strategy demonstrates high sensitivity for TNP assay, and a detection limit of 0.03μM is obtained, which is lower than those reported by using organic fluorescent materials. More significantly, this approach shows outstanding selectivity over a number of TNP analogues, such as 2,4,6-trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), 2,4-dinitrophenol (DNP), 3-nitrophenol (NP), nitrobenzene (NB), phenol (BP), and toluene (BT). Compared with previous studies, this method does not need complex DNA sequence design, fluorescent dye labeling, or sophisticated organic reactions, rendering the strategy with additional advantages of simplicity and cost-effectiveness. In addition, the as-proposed strategy has been adopted for the detection of TNP in natural water samples, indicating its great potential to be applied in the fields of public safety and environmental monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhan, Dejin; Roy, Margaret R; Valera, Christine; Cardenas, Jesse; Vennari, Joann C; Chen, Janice W; Liu, Shengjiang
2002-12-01
A real time quantitative PCR assay has been developed for detecting minute virus of mice (MVM). This assay directly quantifies PCR product by monitoring the increase of fluorescence intensity emitted during enzymatic hydrolysis of an oligonucleotide probe labelled covalently with fluorescent reporting and quenching dyes via Taq polymerase 5'-->3' exonuclease activity. The quantity of MVM DNA molecules in the samples was determined using a known amount of MVM standard control DNA fragment cloned into a plasmid (pCR-MVM). We have demonstrated that MVM TaqMan PCR assay is approximately 1000-fold more sensitive than the microplate infectivity assay with the lowest detection limit of approximately one particle per reaction. The reliable detection range is within 100 to 10(9) molecules per reaction with high reproducibility. The intra assay variation is <2.5%, and the inter assays variation is <6.5% when samples contain >100 particles/assay. When we applied the TaqMan PCR to MVM clearance studies done by column chromatography or normal flow viral filtration, we found that the virus removal factors were similar to that of virus infectivity assay. It takes about a day to complete entire assay processes, thus, the TaqMan PCR assay is at least 10-fold faster than the infectivity assay. Therefore, we concluded that this fast, specific, sensitive, and robust assay could replace the infectivity assay for virus clearance evaluation. Copyright 2002 The International Association for Biologicals. Published by Elsevier Science Ltd. All rights reserved.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
Implementation of Novel Design Features for qPCR-Based eDNA Assessment
Veldhoen, Nik; Hobbs, Jared; Ikonomou, Georgios; Hii, Michael; Lesperance, Mary; Helbing, Caren C.
2016-01-01
Environmental stewardship requires timely, accurate information related to the status of a given ecosystem and the species that occupy it. Recent advances in the application of the highly sensitive real-time quantitative polymerase chain reaction (qPCR) towards identification of constituents within environmental DNA (eDNA) now allow targeted detection of the presence of species-specific biological material within a localized geographic region. However, as with all molecular techniques predicated on the specificity and sensitivity of the PCR assay, careful validation of each eDNA qPCR assay in development must be performed both under controlled laboratory conditions and when challenged with field-derived eDNA samples. Such a step-wise approach forms the basis for incorporation of innovative qPCR design features that strengthen the implementation and interpretation of the eDNA assay. This includes empirical determination that the qPCR assay is refractory to the presence of human DNA and the use of a tripartite assay approach comprised of 1) a primer set targeting plant chloroplast that evaluates the presence of amplifiable DNA from field samples to increase confidence in a negative result, 2) an animal group primer set to increase confidence in the assay result, and 3) a species-specific primer set to assess presence of DNA from the target species. To demonstrate this methodology, we generated eDNA assays specific for the North American bullfrog (Lithobates (Rana) catesbeiana) and the Rocky Mountain tailed frog (Ascaphus montanus) and characterized each with respect to detection sensitivity and specificity with demonstrated performance in a field survey scenario. The qPCR design features presented herein address specific challenges of eDNA assays thereby increasing their interpretative power. PMID:27802293