A Rare Case of Neglected Traumatic Anterior Dislocation of Hip in a Child.
Mootha, Aditya Krishna; Mogali, Kasi Viswanadam
2016-01-01
Post traumatic hip dislocations are very rare in children. Neglected anterior hip dislocations in children are not described in literature so far. Here, we present a case of 6 weeks old anterior hip dislocation successfully managed by open reduction. A 9-year-old male child presented with neglected anterior hip dislocation on left side. Open reduction carried out through direct anterior approach to hip. Congruent reduction is achieved. At final follow up of 1 year, the child had unrestricted activities of daily living and no radiological signs of osteonecrosis or any joint space reduction. There is paucity of literature over neglected post traumatic anterior hip dislocations in children. The treatment options vary from closed reduction after heavy traction to sub trochanteric osteotomy. However, we feel that open reduction through direct anterior approach is the preferred mode of management whenever considered possible.
Delaney, Ruth; Albright, Maurice; Rebello, Gleeson
2011-01-01
Retained intra-articular missiles from low-velocity handguns can lead to mechanical arthritis, synovitis, and lead toxicity. Various surgical approaches have been described to extract such foreign bodies from the hip joint. We present the case of a 17-year-old male in which the surgical dislocation approach was utilized to retrieve a bullet from the femoral head with a good short-term outcome. This case represents a rare application of the surgical hip dislocation approach for an unusual trauma. PMID:23198205
Pathak, Aditya C; Patil, Atul K; Sheth, Binoti; Bansal, Rohan
2012-01-01
Traumatic neglected dislocations of hip in children are rare entity. Neglected traumatic dislocations of hip in children along with heterotopic ossification are still rare. Post traumatic neglected hip dislocations are to be diagnosed as early as possible and have to be treated with precision and aggression as the outcome of treatment for the same is not predictable. 5 year female with post-traumatic neglected hip dislocation with heterotopic ossification forming a pseudoacetabulum postero-superiorly in which femur head was lodged. The girl was operated by open reduction using Moore's Posterior approach and showed good results. Here is a mention of a rare case with a good 18 months follow up with no complication. Post-traumatic neglected posterior hip dislocation mostly requires open reduction and relocation of femoral head in original acetabulum with concentric reduction. Heterotopic ossification is a rare but known complication of traumatic dislocation of hip in children. Good results can be achieved in such cases and regular follow-up of patient is required post-operatively.
Miyake, Takahito; Kanda, Akio; Morohashi, Itaru; Obayashi, Osamu; Mogami, Atsuhiko; Kaneko, Kazuo
2017-06-01
Bipolar hip arthroplasty is a good option for treating femoral neck fractures, although some contraindications have been indicated. We report a case of intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty. A 74-year-old woman underwent bipolar hip arthroplasty for a femoral neck fracture (AO31-B2). She was placed in a lateral decubitus position, and a direct lateral approach was used. During intraoperative trial reduction, the trial bipolar cup became disengaged and dislocated into the anterior space of hip joint. Several attempts to retrieve it failed. The permanent femoral component was inserted, and the wound was closed. The patient was repositioned supine to allow an ilioinguinal approach, and the component was easily removed. She had an uneventful, good recovery. Several cases of intraoperative dislocation of the femoral trial head during total hip arthroplasty have been reported, this is the first report of dislocation of a bipolar trial cup. A previous report described difficulty retrieving a trial cup. We easily removed our trial cup using another approach. It is vital to plan systematically for this frustrating complication.
Surgical Dislocation of the Hip for the Treatment of Pre-Arthritic Hip Disease.
Beaulé, Paul E; Singh, Amardeep; Poitras, Stéphane; Parker, Gillian
2015-09-01
The purpose of this study was to report the clinical results of surgical dislocation of the hip in the treatment of pre-arthritic hip disease. Between 2005 and 2010, eighty-two patients (89 hips) underwent a surgical dislocation of the hip at a mean age of 30.5 years (range 14.8-51.7); 10 females and 72 males. At a mean follow-up of 7.1 years (range 5-9.6) clinical function improved significantly. 6 patients were converted to total hip arthroplasty and 3 patients underwent an arthroscopy and an additional three patients had >1mm of joint space narrowing at latest follow-up giving us a 9-year cumulative Kaplan-Meier survivorship of 86.4% (CI, 79% to 94%). Thirty-four patients underwent internal fixation removal at a mean of 12.0 months (range 0.3-40.8 months). Although effective in the treatment of early hip disease, the surgical dislocation approach carries a high re-operation rate for removal of internal fixation; consequently, less invasive approaches should be considered for less complex deformities. Copyright © 2015 Elsevier Inc. All rights reserved.
Ho, Ki Wai Kevin; Whitwell, George S; Young, Steve K
2012-07-01
We report how changes to our total hip arthroplasty (THA) surgical practise lead to a decrease in early hip dislocation rates. Group B consisted of 421 consecutive primary THA operations performed via a posterior approach. The operative technique included a meticulous repair of the posterior capsule, alignment of the acetabular cup with the transverse acetabular ligament (TAL) and a 36-mm-diameter femoral head. We compared the dislocation rates and cost implications of this technique to a historical control Group A consisting of 389 patients. The control group had their THA performed with no repair of the capsule, no identification of the TAL and all received a 28-mm-diameter head. Our primary outcome is the rate of early hip dislocation and we hypothesised that we can reduce the rate of early hip dislocation with this new regime. In Group B there were no early dislocations (within 6 months) and two (0.5 %) dislocations within 18 months; minimum follow-up time was 18 months with a range of (18-96 months). This compared to a 1.8 % early dislocation rate and a 2.6 % rate at 18 months in Group A; minimum follow-up time was 60 months with a range of (60-112 months). These results were statistically significant (p = 0.006). We suggest that when primary hip arthroplasty is performed through a posterior approach, a low early dislocation rate can be achieved using the described methods.
Sariali, Elhadi; Klouche, Shahnez; Mamoudy, Patrick
2012-07-01
The components position is a major factor under the surgeon's control in determining the risk of dislocation post total hip arthroplasty. The aim of this study was to investigate the proper three-dimensional components position including the centre of rotation in the case of anterior dislocation. Among 1764 consecutive patients who underwent total hip arthroplasty using a direct anterior approach, 27 experienced anterior dislocation. The three-dimensional hip anatomy was investigated in 12 patients who were paired with 12 patients from the same initial cohort who did not experience dislocation and also with 36 control patients with osteoarthritis. A pelvic Cartesian referential was defined to perform the acetabular analysis. The coordinates were expressed as percentages of the pelvic width, height and depth. The anteversion angles were measured. The hip centre of rotation was significantly shifted medially and posteriorly in the dislocation group when compared to the non-dislocation group and also to the control group. There was no significant difference in component angular position between the dislocation-group and the non-dislocation group. However, the stem anteversion in the dislocation group was increased in comparison to the mean natural femoral anteversion of the control group. A medial and posterior displacement of the hip rotation centre was found to correlate to anterior dislocation post total hip arthoplasty. These results suggest the importance of an accurate restoration of the centre of rotation, whilst avoiding an excessive acetabular reaming which may induce a medial and a posterior displacement. III comparative non randomised. Copyright © 2011 Elsevier Ltd. All rights reserved.
Bouchet, R; Mercier, N; Saragaglia, D
2011-02-01
Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations. Although results are barely significant, a larger series should confirm the benefit of this implant. In this series, morbidity was not increased with dual mobility cups. Level III: retrospective case-control study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Zijlstra, Wierd P; De Hartog, Bas; Van Steenbergen, Liza N; Scheurs, B Willem; Nelissen, Rob G H H
2017-01-01
Background and purpose Recurrent dislocation is the commonest cause of early revision of a total hip arthropasty (THA). We examined the effect of femoral head size and surgical approach on revision rate for dislocation, and for other reasons, after total hip arthroplasty (THA). Patients and methods We analyzed data on 166,231 primary THAs and 3,754 subsequent revision THAs performed between 2007 and 2015, registered in the Dutch Arthroplasty Register (LROI). Revision rate for dislocation, and for all other causes, were calculated by competing-risk analysis at 6-year follow-up. Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons. Results Posterolateral approach was associated with higher dislocation revision risk (HR =1) than straight lateral, anterolateral, and anterior approaches (HR =0.5–0.6). However, the risk of revision for all other reasons (especially stem loosening) was higher with anterior and anterolateral approaches (HR =1.2) and lowest with posterolateral approach (HR =1). For all approaches, 32-mm heads reduced the risk of revision for dislocation compared to 22- to 28-mm heads (HR =1 and 1.6, respectively), while the risk of revision for other causes remained unchanged. 36-mm heads increasingly reduced the risk of revision for dislocation but only with the posterolateral approach (HR =0.6), while the risk of revision for other reasons was unchanged. With the anterior approach, 36-mm heads increased the risk of revision for other reasons (HR =1.5). Interpretation Compared to the posterolateral approach, direct anterior and anterolateral approaches reduce the risk of revision for dislocation, but at the cost of more stem revisions and other revisions. For all approaches, there is benefit in using 32-mm heads instead of 22- to 28-mm heads. For the posterolateral approach, 36-mm heads can safely further reduce the risk of revision for dislocation. PMID:28440704
Li, Lianhua; Ren, Jixin; Liu, Jia; Wang, Hao; Sang, Qinghua; Liu, Zhi; Sun, Tiansheng
2016-12-01
Hip dislocation after treatment of a femoral neck fracture with a hemiarthroplasty remains an important problem in the treatment of hip fractures, but the associations between patient factors and surgical factors, and how these factors contribute to dislocation in patients who have undergone bipolar hemiarthroplasty through an anterolateral approach for femoral neck fracture currently are only poorly characterized. We evaluated patients with bipolar hemiarthroplasty dislocation after surgery for femoral neck fracture treated through an anterolateral approach and asked: (1) What are the frequency, characteristics, and risk factors of bipolar hemiarthroplasty dislocations? (2) What are the frequency, characteristics, and risk factors of bipolar hemiarthroplasty dissociations? A review of hospital records for patients who underwent bipolar hip hemiarthroplasty for femoral neck fracture at one hospital between July 2004 and August 2014 was conducted. During that time, 1428 patients were admitted with a diagnosis of femoral neck fracture; 508 of these patients underwent bipolar hip hemiarthroplasty, of whom 61 died and 23 were lost to followup during the first year, leaving 424 (83%) available for analysis. The remainder of the patients during that time were treated with internal fixation (512), unipoloar hip arthroplasty (17), or THA (391). For each patient with dislocation, we selected five control patients from the cohort according to sex, age (± 3 years), and year of entry in the study to eliminate some confounding factors. We recorded patient characteristics regarding demographics, medical comorbidities, Katz score, American Society of Anesthesiologists score, Mini-Mental State Examination (MMSE) score, and anesthesia type. Medical comorbidities included diabetes, chronic pulmonary disease, heart disease, neuromuscular diseases, and dementia. Univariate analyses were used to search for possible risk factors. Conditional logistic regression analyses on dislocation or dissociation were performed to estimate hazard rates (HRs) and corresponding 95% CIs with covariates of a probability less than 0.1 in univariate analysis. In this cohort, there were 26 dislocations including four that were also dissociations. The proportion of patients experiencing a dislocation was 6% (26 of 424). The mean interval from surgery to dislocation was 56 weeks (range, 0-433 weeks), and 18 dislocations (69%) occurred within 3 months after surgery. Three variables were independently associated with an increased risk of hip dislocation: dementia (HR, 3.51; 95% CI, 1.19-10.38; p = 0.02), discrepancy of offset (HR, 1.72; 95% CI, 1.15-2.58; p = 0.008), and lower MMSE score (HR, 0.93; 95% CI, 0.88-0.98; p = 0.007). The proportion of patients experiencing a dissociation was 0.9% (four of 424). The result of conditional logistic regression for dissociation showed that cup size smaller than 43 mm was the risk factor (HR = 513.05). However, there was no statistical difference with the probability equaling 0.47. After the anterolateral approach for treatment of femoral neck fracture using bipolar hemiarthroplasty, 6% of hips dislocated and 0.9% experienced dissociation. Cognitive dysfunction and discrepancy of offset were independent risk factors associated with an increased risk of prosthetic dislocation. The small cup without a safety ring may be the risk factor of dissociation. Discrepancy of offset should be avoided during the operation by performing an accurate femoral osteotomy and choosing an adequate femoral stem neck length. For patients with cognitive dysfunction and a small cup, suturing the joint capsule during the operation and reinforcing protective measures after surgery might reduce the occurrence of dislocation and dissociation, however a study addressing this is necessary to confirm this. Level III, therapeutic study.
Hip arthroscopy using the lateral approach.
Glick, J M
1988-01-01
The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.
Bache, Christopher Edward; Graham, H Kerr; Dickens, D Robert V; Donnan, Leo; Johnson, Michael B; Nattrass, Gary; O'Sullivan, Mark; Torode, Ian P
2008-09-01
When closed reduction of a developmental dislocation of the hip fails, some form of open reduction is required. In recent years, the many advantages of the medial approach open reduction have been emphasized. However, there have been suggestions that the rate of growth disturbance in the proximal femur and the requirement for secondary surgical procedures may be higher with this route than with others. The purpose of this study was to investigate the efficacy and safety of a modified medial approach open reduction, in which the stability of the reduction is enhanced by resection of the redundant ligamentum teres and suturing of the stump of the tendon to the anteromedial capsule. The hospital records and radiographs of 92 infants and children with 109 dislocated hips were reviewed retrospectively. Key demographic and pretreatment data were collected by the first author and compared with the outcome at the most recent follow-up. In addition, 69 children returned for a clinical evaluation by the first author. The outcome at the most recent follow-up was graded according to Severin, and associations were sought between pretreatment grade of dislocation according to Tonnis, the presence of ossific nucleus, changes in the acetabular index, the requirements for secondary surgery, associations with previous treatment, and the position of abduction in the postoperative cast. At a mean follow-up of 9 years, 89% of hips were classified as Severin grade 1 or 2. Avascular necrosis (AVN) was classified according to the system of Kalamchi and MacEwen. The incidence of AVN was 41%, but two thirds of these were grade 1 (temporary irregular ossification), and the Severin grading in these hips was not compromised. The presence of ossification in the capital epiphysis and a range of abduction of less than 60 degrees in the hip spica were noted to be protective against the development of AVN. Three hips redislocated and required additional treatment. Thirty-eight hips required a total of 44 additional surgical procedures. We have demonstrated that it is possible to use a medial approach for open reduction of the congenitally dislocated hip in combination with tenodesis of the ligamentum teres to the anteromedial joint capsule. The incidence of growth disturbance in the proximal femur is high and cumulative with long-term follow-up. However, in this large series, the rate of hip stability, growth disturbance, and need for secondary surgery are comparable to other series. We conclude that the many advantages of open reduction by the medial approach outweigh the disadvantages.
Acetabular cup position and risk of dislocation in primary total hip arthroplasty.
Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill
2017-02-01
Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.
Acetabular cup position and risk of dislocation in primary total hip arthroplasty
Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill
2017-01-01
Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150
Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru
2018-03-09
In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.
Framing Hip Hop: New Methodologies for New Times
ERIC Educational Resources Information Center
Dimitriadis, Greg
2015-01-01
This article revisits the central impulse behind early advocacy for ethnographic approaches to hip hop--that critics should try as much as possible to limit their own certainties around what hip hop can and might mean. While ethnographic approaches can engender the kinds of personal dislocations that allow for this negotiation, they do not…
Kornuijt, A; Das, D; Sijbesma, T; van der Weegen, W
2016-05-01
In order to prevent dislocation of the hip after total hip arthroplasty (THA), patients have to adhere to precautions in the early post-operative period. The hypothesis of this study was that a protocol with minimal precautions after primary THA using the posterolateral approach would not increase the short-term (less than three months) risk of dislocation. We prospectively monitored a group of unselected patients undergoing primary THA managed with standard precautions (n = 109, median age 68.9 years; interquartile range (IQR) 61.2 to 77.3) and a group who were managed with fewer precautions (n = 108, median age 67.2 years; IQR 59.8 to 73.2). There were no significant differences between the groups in relation to predisposing risk factors. The diameter of the femoral head ranged from 28 mm to 36 mm; meticulous soft-tissue repair was undertaken in all patients. The medical records were reviewed and all patients were contacted three months post-operatively to confirm whether they had experienced a dislocation. There were no dislocations in the less restricted group and one in the more restricted group (p = 0.32). For experienced surgeons using the posterolateral approach at THA and femoral heads of diameter ≥ 28 mm, it appears safe to manage patients in the immediate post-operative period with minimal precautions to protect against dislocation. Larger studies with adequate statistical power are needed to verify this conclusion. Experienced orthopaedic surgeons using the posterolateral approach for THA should not fear an increased dislocation rate if they manage their patients with a minimal precautions protocol. Cite this article: Bone Joint J 2016;98-B:589-94. ©2016 The British Editorial Society of Bone & Joint Surgery.
Traumatic hip dislocation at a regional trauma centre in Nigeria.
Onyemaechi, N O C; Eyichukwu, G O
2011-01-01
Traumatic dislocation or fracture-dislocation of the hip is an orthopaedic emergency that is steadily increasing in incidence due to high-speed motor vehicular accidents. These injuries need to be recognized early and promptly treated to prevent morbidity and long-term complications. Some of the fundamental issues in the management of traumatic dislocations of the hip are the critical interval between injury and reduction, the type of reduction most suitable for various types of injury and the duration of immobilization that give the best results. This study was carried out at the National Orthopaedic Hospital Enugu, a regional trauma and orthopaedic centre in South-East Nigeria. The purpose of the study is to describe the pattern of presentation and to identify the factors that determine the long-term outcome in the treatment of traumatic dislocations and fracture-dislocations of the hip at Enugu, Nigeria. The case notes of all the patients that presented with traumatic dislocations and fracture-dislocations of the hip between January 2003 and December 2007 were reviewed. The information extracted and analyzed included the patients' demographics, etiology of injury, time interval before reduction, associated injuries, treatment offered, complications and follow-up. Thompson-Epstein classification was used to grade the posterior hip dislocations. The outcome of treatment was evaluated using the clinical and radiological criteria proposed by Epstein (1974). Three patients with incomplete data and two patients with central fracture dislocation were excluded from this study. Forty-eight patients with 50 hip dislocations were analyzed. The age range was 12 years to 67 years with a mean age of 34.8 years. Thirty-nine patients (81.3%) were males and 9 (18.7%) were females. Road-traffic accident was the leading cause of traumatic hip dislocation in this series, 44 cases (91.6%). Posterior dislocation occurred in 48 hips (96%) while anterior dislocation occurred in 2 hips (4%). Forty-seven hips (94%) were treated by primary closed reduction, two hips (4%) were treated with open reduction and one patient (2%) had Girdlestone excision arthroplasty. Thirty-six hips (73.5%) were reduced with 12 hours of the injury. Concomitant injuries were found in 37 patients (77%). The follow up period ranged from 10 months to 36 months with a mean follow up period of 15 months. Post-traumatic osteoarthritis occurred in 2 hips (4%) avascular necrosis of the femoral head was seen in 2 hips (4%). Five patients had sciatic nerve paresis while there was recurrence in one hip. No mortality was recorded. Traumatic dislocations and fracture-dislocations of the hip are severe injuries caused mostly by high-speed motor-vehicular accidents. Young adult males are most commonly affected, and there is a high rate of concomitant injuries. Excellent results can be achieved by early and stable closed reduction of these injuries with immobilization of the affected hips.
Late septic hip dislocation with multifocal osteomyelitis and malaria: a case report.
Sreenivas, T; Menon, Jagdish; Nataraj, A R
2012-12-01
A 9-year-old boy presented with high-grade fever associated with pain and swelling in right hip and left leg of 1-week duration. Pus was found on diagnostic aspiration of the right hip joint. Emergency arthrotomy was performed through anterior approach with drill holes in proximal femur and culture showed MRSA. Intravenous antibiotics were given for 4 weeks. Patient symptomatically improved in immediate postoperative period and in bed hip mobilization was started. On eighth postoperative day, child developed high-grade intermittent fever with chills and rigors and diagnosed as plasmodium falciparum malaria. Fever subsided with antimalarial treatment. On twenty-first day, patient complained pain in right hip and X-ray showed posterior hip dislocation with osteomyelitis of proximal femur. Closed reduction and hip spica application was done under general anesthesia. At follow-up, the clinical result was fair with resolution of infection and stiff hip.
Ipsilateral hip and knee dislocation: Case report and review of literature
Sharma, Gaurav; Chahar, Deepak; Sreenivasan, Ravi; Verma, Nikhil; Pankaj, Amite
2016-01-01
Hip and knee dislocations are not uncommon but simultaneous ipsilateral dislocation of the hip and knee joint is rare; consequently, there is an inadequate amount of literature on the subject. We identified only 11 such cases reported in English literature. In the present report, we describe the case of a 23-year-old male patient who presented with ipsilateral hip and knee dislocation on the right side after being involved in a road traffic accident. The hip dislocation was associated with a posterior wall acetabular fracture. The hip as well as the knee joints was reduced in the emergency bay. The patient underwent an urgent fixation of the posterior wall acetabular fracture with delayed ligament reconstruction for the knee dislocation. At one-year follow-up, he had no pain in the hip or knee. There was grade 1 posterior sag but no symptoms of knee instability. Radiographs revealed no evidence of avascular necrosis or arthritis of the femoral head. The normal treatment protocol for individual injury is affected by the simultaneous occurrence of hip and knee dislocation. PMID:27182149
Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement
Zhang, Dagang; Chen, Long; Wang, Guanglin
2016-01-01
Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133
Bakalakos, Matthaios; Benetos, Ioannis S; Rozis, Meletios; Vlamis, John; Pneumaticos, Spiros
2018-06-02
The majority of injuries during a football game are contusions, sprains and/or strains in the thigh, knee and ankle. Hip dislocations account for 2-5% of total hip dislocations, and they can be posterior or anterior. Major complications of traumatic hip dislocation include avascular necrosis of femoral head, secondary osteoarthritis, sciatic nerve injury and heterotopic ossification. On the occasion of a case of a 33-year-old football player, who suffered a posterior hip dislocation, associated with a posterior wall fracture of the acetabulum, while playing football, we review the literature and analyze the various mechanisms of injury, the possible complications and the management including surgery and rehabilitation.
Flynn, John M; Ramirez, Norman; Betz, Randal; Mulcahey, Mary Jane; Pino, Franz; Herrera-Soto, Jose A; Carlo, Simon; Cornier, Alberto S
2010-01-01
A syndrome of children with short stature, bilateral hip dislocations, radial head dislocations, carpal coalitions, scoliosis, and cavus feet in Puerto Rican children, was reported by Steel et al in 1993. The syndrome was described as a unique entity with dismal results after conventional treatment of dislocated hips. The purpose of this study is to reevaluate this patient population with a longer follow-up and delineate the clinical and radiologic features, treatment outcomes, and the genetic characteristics. This is a retrospective cohort study of 32 patients in whom we evaluated the clinical, imaging data, and genetic characteristics. We compare the findings and quality of life in patients with this syndrome who have had attempts at reduction of the hips versus those who did not have the treatment. Congenital hip dislocations were present in 100% of the patients. There was no attempt at reduction in 39% (25/64) of the hips. In the remaining 61% (39/64), the hips were treated with a variety of modalities fraught with complications. Of those treated, 85% (33/39) remain dislocated, the rest of the hips continue subluxated with acetabular dysplasia and pain. The group of hips that were not treated reported fewer complaints and limitation in daily activities compared with the hips that had attempts at reduction. Steel syndrome is a distinct clinical entity characterized by short stature, bilateral hip and radial head dislocation, carpal coalition, scoliosis, cavus feet, and characteristic facial features with dismal results for attempts at reduction of the hips. Prognostic Study Level II.
Neglected Posterior Dislocation of Hip in Children - A Case Report.
Pal, Chandra Prakash; Kumar, Deepak; Sadana, Ashwani; Dinkar, Karuna Shankar
2014-01-01
Traumatic dislocation of the hip in children is a rare injury. We report the outcome of 2 patients of neglected hip dislocation which were treated by open reduction and internal fixation by k-wires. We treat 2 children both girls (one was of 4 years and other was 7 years of age). In both cases dislocation was unilateral and was not associated with any facture. Both cases were of posterior dislocation. in both cases open reduction and internal fixation was done by k wires. Hip spica was applied post operatively in both cases. The k wire was removed at 3 to 4 weeks. Patients were allowed to bear weight from gradual to full weight bearing after 6 weeks. We conclude that open reduction is a satisfactory treatment for neglected hip dislocation. It prevents not only deformity but also maintains limb length.
Open and Arthroscopic Surgical Treatment of Femoroacetabular Impingement
Kuhns, Benjamin D.; Frank, Rachel M.; Pulido, Luis
2015-01-01
Femoroacetabular impingement (FAI) is a common cause of hip pain, and when indicated, can be successfully managed through open surgery or hip arthroscopy. The goal of this review is to describe the different approaches to the surgical treatment of FAI. We present the indications, surgical technique, rehabilitation, and complications associated with (1) open hip dislocation, (2) reverse periacetabular osteotomy, (3) the direct anterior “mini-open” approach, and (4) arthroscopic surgery for FAI. PMID:26697431
Hoggett, L; Cross, C; Helm, T
2017-12-01
Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.
Arjun, R H H; Kumar, Vishal; Saibaba, Balaji; John, Rakesh; Guled, Uday; Aggarwal, Sameer
2016-09-01
The incidence of traumatic hip dislocations in children is rising in this fast developing world along with increasing numbers of high-velocity road traffic accidents. Anterior dislocation of the hip has a lower incidence compared with posterior dislocation of the hip. We encountered a rare case of the obturator type of anteriorly dislocated hip associated with ipsilateral fracture of the shaft femur in an 11-year-old child. This is a highly unusual injury combination and the mechanism of injury is obscure. Only two similar cases have been reported in the English literature to date. Closed reduction of the hip using a hitherto undescribed technique and an intramedullary interlocking nail was performed in this case. At 6 months of follow-up, the fracture shaft femur has united and the child is bearing full weight on the limb.
A Rare Case of Morel-Lavallee Syndrome Complicating an Anterior Dislocation of Hip Joint.
Nekkanti, Supreeth; Vijay, C; Theja, Sujana; Shankar, R Ravi; Verma, Anubhav
2016-01-01
Hip dislocations are serious injuries as hip joint is an extremely stable joint. It requires a significant amount of force to produce such an injury. Anterior dislocations are uncommon. Potential complications of anterior hip dislocations are a neurovascular injury to femoral vessels or acetabular fractures. We report a rare late complication of Morel-Lavallee syndrome occurring 3 weeks after an anterior dislocation of the hip in a 43-year-old male. The patient presented to us with history. Morel-Lavallee syndrome is a rare complication. However if diagnosed early can be successfully treated with minimal burden to the patient. The authors recommend surgeons to have a high index of suspicion for this syndrome and a stringent follow-up examination of the patient.
On the permanent hip-stabilizing effect of atmospheric pressure.
Prietzel, Torsten; Hammer, Niels; Schleifenbaum, Stefan; Kaßebaum, Eric; Farag, Mohamed; von Salis-Soglio, Georg
2014-08-22
Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that is discussed until today is atmospheric pressure which is not taken into account in the present THA concepts. The aim of this study was to investigate the impact of atmospheric pressure on hip joint stability. Five joint models (Ø 28-44 mm), consisting of THA components were hermetically sealed with a rubber capsule, filled with a defined amount of fluid and exposed to varying ambient pressure. Displacement and pressure sensors were used to record the extent of dislocation related to intraarticular and ambient pressure. In 200 experiments spontaneous dislocations of the different sized joint models were reliably observed once the ambient pressure was lower than 6.0 kPa. Increasing the ambient pressure above 6.0 kPa immediately and persistently reduced the joint models until the ambient pressure was lowered again. Displacement always exceeded half the diameter of the joint model and was independent of gravity effects. This experimental study gives strong evidence that the hip joint is permanently stabilized by atmospheric pressure, confirming the theories of Weber and Weber (1836). On basis of these findings the use of larger prosthetic heads, capsular repair and the deployment of an intracapsular Redon drain are proposed to substantially decrease the risk of dislocation after THA. Copyright © 2014 Elsevier Ltd. All rights reserved.
Howie, Donald W; Holubowycz, Oksana T; Middleton, Robert
2012-06-20
The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference, 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established.
An update on surgical approaches in hip arthoplasty: lateral versus posterior approach.
Mukka, Sebastian S; Sayed-Noor, Arkan S
2014-10-02
In this update we searched the literature about the outcome of the lateral versus posterior approach in hip arthoplasty for osteoarthritis (OA) and femoral neck fracture (FNF) patients. The available evidence shows that the use of posterior approach in OA patients is associated with lower mortality and better functional outcome while the use of lateral approach in FNF patients gives lower dislocation rate. We recommend therefore the use of posterior approach in OA patients and lateral approach in FNF patients.
Schwabe, P; Märdian, S; Perka, C; Schaser, K-D
2016-04-01
Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.
Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
Lee, Young-Kyun; Ha, Yong-Chan; Jo, Woo-Lam; Kim, Tae-Young; Jung, Woon-Hwa; Koo, Kyung-Hoi
2016-05-01
Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Kobayashi, Seneki; Kubo, Toshikazu; Iwamoto, Yukihide; Fukushima, Wakaba; Sugano, Nobuhiko
2018-05-12
To identify modifiable factors related to post-operative dislocation and reoperation in patients with osteonecrosis of the femoral head (ONFH) in a large cohort. We studied 4995 hip arthroplasties: total hip arthroplasty (THA) was performed in 79% of patients; bipolar hemiarthroplasty (BP), 17%; total resurfacing arthroplasty (tRS), 3%; and hemi-resurfacing arthroplasty (hRS), 1%. A new type of BP (accounting for 49% of BPs) comprised a femoral component with a polished or smooth, small-diameter (approximately 10 mm) neck with a round or oval axial cut surface and no sharp corners. The infection rate was relatively low (0.56%) even though 58% of cases of ONFH were associated with systemic steroid use, a known risk factor for infection. Post-operative dislocation occurred in 4.3% of cases, with re-operation needed in 3.9%. The dislocation rate was related to surgery type: 5.2% in THA, 0.9% in BP, and 0% in tRS and hRS. Among total arthroplasties with six month or longer follow-up (3670 THAs and 159 tRSs), the risk factors for post-operative dislocation were younger (≤ 40 years) or older (≥ 62 years) age, higher body weight, posterolateral approach, and smaller prosthetic head diameter. Regarding the need for re-operation, higher body weight and surgery type were identified as risk factors. The relatively high dislocation rate of 5.2% in THA is a cause for concern. The identified risk factors for dislocation should be considered when selecting THA for treatment. Prosthesis survivorship in hRSs was inferior to that in BPs or THAs. Body weight also affected the survivorship of hip arthroplasties.
Kellam, Patrick; Ostrum, Robert F
2016-01-01
To determine the incidence rate and associative factors for the development of avascular necrosis (AVN) and posttraumatic arthritis (PTA) after traumatic hip dislocation and time to reduction. A comprehensive search of databases including PubMed, Cochrane Database, and Embase through April 2014 for English articles reporting complications of AVN and PTA after hip dislocation was performed. Inclusion criteria were English-only studies, a patient population of adults, study outcomes of AVN and/or PTA reported, and articles reported at least type I dislocations. Two authors independently extracted data from the selected studies and the data collected were compared to verify agreement. Random-effects models were used for meta-analysis. The overall event rate of AVN and PTA was calculated and stratified based on Thompson-Epstein of the hip dislocation. Odds ratios were calculated for those articles that reported rates of AVN based on time to reduction. For anterior dislocations, the event rate for AVN ranged from 0.087 to 0.333, whereas the event rate for PTA ranged from 0.125 to 0.700. Analysis of posterior dislocations revealed that the event rate for AVN ranged from 0.106 to 0.430; additionally, the event rate for PTA ranged from 0.194 to 0.586. For posterior hip dislocations and type I and II anterior dislocations, the severity of the injury correlates with an increase in the development of AVN and PTA. The odds ratio of AVN for those hip dislocations reduced after 12 hours versus those reduced before 12 hours was 5.627. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
[Acute traumatic and especially neglected traumatic hip dislocations are very rare in children].
Fernandez, F F; Wirth, T; Eberhardt, O
2012-09-01
We report about the first hip arthroscopies of extracapsular neglected hip dislocations with concomitant injuries in two children (2 and 4 years old). The major problem of traumatic hip dislocation is avascular necrosis. Further problems are possible concomitant injuries. It is important not to cause further damage by therapeutic procedures. In a 4-year-old child the hip could be reduced under visualization and in a 2-year-old child with epiphyseal fracture the extent of the operation could be reduced. In both children large avulsion injuries of the ligamentum capitis femoris could be resected via hip arthroscopy. Hip arthroscopy can reduce surgical morbidity considerably and can possibly contribute to prevention of the feared avascular necrosis of the femoral head.
Fessy, M H; Putman, S; Viste, A; Isida, R; Ramdane, N; Ferreira, A; Leglise, A; Rubens-Duval, B; Bonin, N; Bonnomet, F; Combes, A; Boisgard, S; Mainard, D; Leclercq, S; Migaud, H
2017-09-01
Dislocation after total hip arthroplasty (THA) is a leading reason for surgical revision. The risk factors for dislocation are controversial, particularly those related to the patient and to the surgical procedure itself. The differences in opinion on the impact of these factors stem from the fact they are often evaluated using retrospective studies or in limited patient populations. This led us to carry out a prospective case-control study on a large population to determine: 1) the risk factors for dislocation after THA, 2) the features of these dislocations, and 3) the contribution of patient-related factors and surgery-related factors. Risk factors for dislocation related to the patient and procedure can be identified using a large case-control study. A multicenter, prospective case-control study was performed between January 1 and December 31, 2013. Four patients with stable THAs were matched to each patient with a dislocated THA. This led to 566 primary THA cases being included: 128 unstable, 438 stable. The primary matching factors were sex, age, initial diagnosis, surgical approach, implantation date and type of implants (bearing size, standard or dual-mobility cup). The patients with unstable THAs were 67±12 [37-73]years old on average; there were 61 women (48%) and 67 men (52%). Hip osteoarthritis (OA) was the main reason for the THA procedure in 71% (91/128) of the unstable group. The dislocation was posterior in 84 cases and anterior in 44 cases. The dislocation occurred within 3 months of the primary surgery in 48 cases (38%), 3 to 12 months after in 23 cases (18%), 1 to 5years after in 20 cases (16%), 5 to 10years after in 17 cases (13%) and more than 10years later in 20 cases. The dislocation recurred within 6 months of the initial dislocation in 23 of the 128 cases (18%). The risk factors for instability were a high ASA score with an odds ratio (OR) of 1.93 (95% CI: 1.4-2.6), neurological disability (cognitive, motor or psychiatric disorders) with an OR of 3.9 (95% CI: 2.15-7.1), history of spinal disease (lumbar stenosis, spinal fusion, discectomy, scoliosis and injury sequelae) with an OR of 1.89 (95% CI: 1.0-3.6), unrepaired joint capsule (all approaches) with an OR of 4.1 (95% CI: 2.3-7.37), unrepaired joint capsule (posterior approach) with an OR of 6.0 (95% CI: 2.2-15.9), and cup inclination outside Lewinnek's safe zone (30°-50°) with OR of 2.4 (95% CI: 1.4-4.0). This large comparative study isolated important patient-related factors for dislocation that surgeons must be aware of. We also found evidence that implanting the cup in 30° to 50° inclination has a major impact on preventing dislocation. Level III; case-control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda
2017-01-01
Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875
Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques
2007-09-01
We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.
Surgical hip dislocation for treatment of cam femoroacetabular impingement.
Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, K N; KoKo, Aung; Zaw, Than; Siddhartha, A
2015-01-01
Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°-108°) to 46.35° (range 39°-58°). Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.
Hoell, Steffen; Sander, Marius; Gosheger, Georg; Ahrens, Helmut; Dieckmann, Ralf; Hauschild, Gregor
2014-03-12
There have been increasing numbers of publications in recent years on minimally invasive surgery (MIS) for total hip arthroplasty (THA), reporting results with the use of different head sizes, tribologic and functional outcomes. This study presents the results and early complication rates after THA using the direct anterior approach (DAA) in combination with head sizes ≥ 36 mm. A total of 113 patients with THA were included in the study. The Harris Hip Score (HHS) was determined, a radiographic evaluation was carried out, and complications were recorded. The minimum follow-up period was 2 years (means 35 ± 7 months). The HHS improved from 43.6 (± 12) to 88.2 (± 14; P < 0.01). One early infection occurred, one periprosthetic fracture, and three cases of aseptic stem loosening. No incorrect positioning of the implants was observed, and there were no dislocations. THA with the minimally invasive DAA in combination with large heads is associated with good to very good functional results in the majority of cases. The complication rates are not increased. The rate of dislocation mainly as an complication of the first two years can be markedly reduced in particular.
Congential dislocation of the hip and adult low back pain: a report of three cases
Kitchen, Robert G; Mierau, Dale; Cassidy, David; Dupuis, Pierre
1988-01-01
Congenital dislocation of the hip (CDH) in an adult can accompany or cause mechanical low-back pain. This in turn, can create confusion in making the proper diagnosis. The mechanical alterations caused by CDH create an added strain to the lumbosacral spine. Manipulative treatment for back pain in these patients must not subject the dislocated hips to undue torque. ImagesFigure 1Figure 2Figure 3Figure 4aFigure 4b
Traumatic fracture-dislocation of the hip following rugby tackle: a case report.
Venkatachalam, Santosh; Heidari, Nima; Greer, Tony
2009-12-15
Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months.
Traumatic fracture-dislocation of the hip following rugby tackle: a case report
2009-01-01
Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months. PMID:20003496
Shindle, Michael K.; Kelly, Bryan T.
2010-01-01
With the improvements in flexible instrumentation, hip arthroscopy is being increasingly used to treat a variety of hip pathology, including labral tears. However, up to this point, there has not been a case report of an anterior and a posterior labral tear successfully repaired arthroscopically. We present a case report of a 27-year-old male firefighter who presented to our institution with an anterior and posterior labral tear, as well as a cam lesion and loose body, following a traumatic hip dislocation. The purpose of this case report is to illustrate that both anterior and posterior labral tears can be repaired using hip arthroscopy. Anterior and posterior labral tears can be caused by a traumatic hip dislocation, and both can be successfully repaired using arthroscopic techniques. PMID:21886540
Furuhashi, Hiroki; Togawa, Daisuke; Koyama, Hiroshi; Hoshino, Hironobu; Yasuda, Tatsuya; Matsuyama, Yukihiro
2017-05-01
Several reports have indicated that anterior dislocation of total hip arthroplasty (THA) can be caused by spinal degenerative changes with excessive pelvic retroversion. However, no reports have indicated that posterior dislocation can be caused by fixed pelvic anteversion after corrective spine surgery. We describe a rare case experiencing repeated posterior THA dislocation that occurred at 5 months after corrective spinal long fusion with pelvic fixation. A 64-year-old woman had undergone bilateral THA at 13 years before presenting to our institution. She had been diagnosed with kyphoscoliosis and underwent three subsequent spinal surgeries after the THA. We finally performed spinal corrective long fusion from T5 to ilium with pelvic fixation (with iliac screws). Five months later, she experienced severe hip pain when she tried to stand up from the toilet, and was unable to move, due to posterior THA dislocation. Therefore, we performed closed reduction under sedation, and her left hip was easily reduced. After the reduction, she started to walk with a hip abduction brace. However, she had experienced 5 subsequent dislocations. Based on our findings and previous reports, we have hypothesized that posterior dislocation could be occurred after spinal corrective long fusion with pelvic fixation due to three mechanisms: (1) a change in the THA cup alignment before and after spinal corrective long fusion surgery, (2) decreased and fixed pelvic posterior tilt in the sitting position, or (3) the trunk's forward tilting during standing-up motion after spinopelvic fixation. Spinal long fusion with pelvic fixation could be a risk factor for posterior THA dislocation.
Bedi, Asheesh; Zaltz, Ira; De La Torre, Katrina; Kelly, Bryan T
2011-07-01
Whether open or arthroscopic techniques are employed, the goal of femoroacetabular impingement (FAI) surgery is to achieve impingement-free range of motion. While arthroscopic approaches have improved and gained popularity, an objective evaluation of the surgical correction achieved with this approach compared with open surgery remains to be defined in the literature. This study was undertaken to compare the efficacy of arthroscopic osteoplasty and open surgical dislocation in treating FAI dysmorphology in a consecutive series of patients. Cohort study; Level of evidence, 3. Surgical treatment was performed in 60 male patients under 40 years of age for symptomatic FAI refractory to nonoperative management. Patients were matched (not randomized) to treatment groups: 30 patients (15 left and 15 right hips) underwent arthroscopic cam and/or rim osteoplasty with labral debridement and/or refixation by an arthroscopic surgeon; and 30 (14 left and 16 right hips) underwent open surgical dislocation, cam and/or rim osteoplasty, and labral debridement or refixation by a hip preservation surgeon. Anteroposterior (AP) pelvis and extended-neck (Dunn) lateral radiographs were obtained and the depth of resection and arc of resection were measured by assessment of anterior femoral head-neck offset, AP and lateral α angle, and β angle on preoperative and postoperative radiographs. In the arthroscopic group, the extended-neck lateral α angle was reduced by a mean of 17.2° (28.3%, P < .05), AP α angle was reduced by a mean of 12.6° (16.8%), anterior head-neck offset improved 5.0 mm (111%, P < .05), and β angle increased by a mean of 23.1°. In the open dislocation group, the extended-neck lateral α angle was reduced by a mean of 21.2° (30.7%, P < .05), AP α angle was reduced by a mean of 20.1° (25.7%), anterior head-neck offset improved 6.56 mm (108%, P < .05), and β angle increased by a mean of 18.35°. Arthroscopic osteoplasty can restore head-neck offset and achieve similar depth, arc, and proximal-distal resection with comparable efficacy to open surgical dislocation for anterior and anterosuperior cam and focal rim impingement deformity. The open technique, however, may allow greater correction of posterosuperior loss of femoral offset and may be favorable for FAI patterns that demonstrate considerable proximal femoral deformity on AP radiographs.
[Total hip arthroplasty through anterior "minimal invasive" approach].
Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A
2012-12-19
Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.
Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N
2004-12-01
Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.
Surgical hip dislocation for treatment of cam femoroacetabular impingement
Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, KN; KoKo, Aung; Zaw, Than; Siddhartha, A
2015-01-01
Background: Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Materials and Methods: Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Results: Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°–108°) to 46.35° (range 39°–58°). Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term. PMID:26538754
... or a blow, sometimes from playing a contact sport. You can dislocate your ankles, knees, shoulders, hips, ... to dislocate it again. Wearing protective gear during sports may help prevent dislocations.
Hip dislocations and concurrent injuries in motor vehicle collisions.
Cooper, Joseph; Tilan, Justin; Rounds, Alexis D; Rosario, Santano; Inaba, Kenji; Marecek, Geoffrey S
2018-04-27
Motor Vehicle Collisions (MVC) can cause high energy hip dislocations associated with serious injury profiles impacting triage. Changes in safety and regulation of restraint devices have likely lowered serious injuries from what was previously reported in the 1990s. This study aims to describe modern-day injury profile of patients with traumatic hip dislocations, with special attention to aortic injury. Retrospective review of a prospectively maintained trauma database at an urban level 1 trauma center was conducted. Patients with hip dislocation following MVC between January 2005 and December 2015 were grouped based on seatbelt use and airbag deployment. Patients with unknown restraint use were excluded. Multiple logistic regression was used to identify risk of injury profile between groups. Of 204 patients with hip dislocation after MVC, nearly 57% were unrestrained. Seatbelt alone was used in 36 (17.7%), airbag deployed in 14 (6.9%), and 38 (18.6%) with both. Gender and number of injuries were similar between groups. The most common concomitant injury was acetabular fracture (53.92%) and the abdominopelvic region was the most injured. Use of a seatbelt with airbag deployment was protective of concomitant pelvic ring injury (OR = 0.22). Airbag deployment was significantly protective of lumbar fracture (OR = 0.15) while increasing the likelihood of radial and ulnar fracture or dislocation (OR = 3.27), acetabular fracture (OR = 5.19), and abdominopelvic injury (OR = 5.07). The no restraint group had one patient (0.80%) with an intimal tear of the thoracic aorta identified on CT chest that was successfully medically managed. Hip dislocations are high energy injuries with severe associated injuries despite upgrades in restraint devices. These patients require careful examination and heightened awareness when evaluating for concomitant injuries. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ahmed, Mohammed M; Otto, Thomas J; Moed, Berton R
2016-04-22
Limited-incision total hip arthroplasty (THA) preserves hip abductors, posterior capsule, and external rotators potentially diminishing dislocation risk. However, potential complications also exist, such as component malposition. Specific implants have been manufactured that enhance compatibility with this technique, while preserving metaphyseal bone; however, little data exists documenting early complications and component position. The purpose was to evaluate primary THA using a curved, bone-sparing stem inserted through the anterior approach with respect to component alignment and early complications. In a retrospective analysis of 108 cases, the surgical technique was outlined and the occurrence of intraoperative fractures, postoperative dislocations, infection, and limb length inequality was determined. Femoral stem and acetabular cup alignment was quantified using the initial postoperative radiographs. Patient follow-up averaged 12.9 (range 2 to 36) months. There were eight (7.4 %) complications requiring revision surgery in three (2.8 %) patients with three (2.8 %) infections and three (2.8 %) dislocations. Intraoperative complications included one calcar fracture above the lesser trochanter. Leg length inequality >5 mm was present in three (2.8 %) patients. Radiographic analysis showed that femoral neutral alignment was achieved in 95 hips (88.0 %). All femoral stems demonstrated satisfactory fit and fill and no evidence of subsidence, osteolysis, or loosening. An average abduction angle of 44.8° (± 5.3) and average cup anteversion of 16.2° (± 4.2) were also noted. Although the technique with this implant and approach is promising, it does not appear to offer important advantages over standard techniques. However, the findings merit further, long-term study.
Steel, H H; Piston, R W; Clancy, M; Betz, R R
1993-02-01
An orthopaedic syndrome that apparently had not been reported previously was identified in twenty-three children. Characteristics shared by all twenty-three children included Hispanic descent, residence in Puerto Rico, bilateral dislocation of the hip, dislocated radial heads, short stature, and other osseous anomalies. Twelve dislocated hips in six patients were not treated. All of these hips were functioning satisfactorily at the time of the review, but only four of the children had reached skeletal maturity. Sixteen hips in eight patients remained reduced after closed reduction. Of these eight patients, the four who were skeletally immature at the time of the review had a satisfactory result, and the four who were skeletally mature had an unsatisfactory result because of discomfort or fibrous ankylosis. Eighteen hips in nine patients were treated with a reduction augmented by some form of operation. All of these hips redislocated. Of the forty-six elbows in the twenty-three children, thirty-three were dislocated, as seen clinically and radiographically; eight were normal, both clinically and radiographically; and there was dysplasia at the radiocapitellar articulation of the remaining five. Twenty of the twenty-three children were found to have carpal coalitions. Fourteen children had scoliosis, and five of them were managed with spinal arthrodesis and correction. Three patients had an anomaly of the cervical spine, with one deformity causing symptoms and signs that were treated with decompression. Eight patients had talipes cavus bilaterally, which was not treated.
Kempthorne, Joshua T; Armour, Paul C; Rietveld, John A; Hooper, Gary J
2011-06-01
Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index scores increased by 23, 28, 34 and 35 points, respectively (P 0.0039). There was no significant improvement in hip range of motion. There were two (4%) early failures with conversion to total hip arthroplasty, and no cases of post-operative avascular necrosis of the femoral head. We believe that as the diagnosis of FAI and conservative nonarthroplasty surgery of the hip gains wider acceptance, it will become a procedure that should be offered to all appropriate patients in an attempt to delay or limit total hip arthroplasty in this young age group.
Yeung, Marco; Memon, Muzammil; Simunovic, Nicole; Belzile, Etienne; Philippon, Marc J; Ayeni, Olufemi R
2016-06-01
Gross hip instability is a rare complication after hip arthroscopy, and there is limited literature surrounding this topic. This systematic review investigates cases of gross hip instability after arthroscopy and discusses the risk factors associated with this complication. A systematic search was performed in duplicate for studies investigating gross hip instability after hip arthroscopy up to October 2015. Study parameters including sample size, mechanism and type of dislocation, surgical procedure details, patient characteristics, postoperative rehabilitation protocol, and level of evidence were analyzed. The systematic review identified 9 case reports investigating gross hip instability after hip arthroscopy (10 patients). Anterior dislocation occurred in 66.7% of patients, and most injuries occurred with a low-energy mechanism. Common surgical factors cited included unrepaired capsulotomy (77.8%) and iliopsoas release (33.3%), whereas patient factors included female gender (77.8%), acetabular dysplasia (22.2%), and general ligamentous laxity (11.1%). Postoperative restrictions and protocols were variable and inconsistently reported, and their relation to post-arthroscopy instability was difficult to ascertain. This systematic review discussed various patient, surgical, and postoperative risk factors of gross hip instability after arthroscopy. Patient characteristics such as female gender, hip dysplasia, and ligamentous laxity may be risk factors for post-arthroscopy dislocation. Similarly, surgical risk factors for iatrogenic hip instability may include unrepaired capsulotomies and iliopsoas debridement, although the role of capsular closure in iatrogenic instability is not clear. The influences of postoperative restrictions and protocols on dislocation are also unclear in the current literature. Surgeons should be cognizant of these risk factors when performing hip arthroscopy and be mindful that these factors appear to occur in combination. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Patient Needs for an Ambulant Dislocation Alert System Following Total Hip Arthroplasty.
Huis In't Veld, Rianne; Peters, Anil; Vollenbroek-Hutten, Miriam; Hermens, Hermie; van den Hoven, Carmen
2018-05-01
One of the major complications in total hip arthroplasty (THA) is dislocation of the prosthesis. To prevent early dislocation, patients are instructed with movement restrictions. The first goal in this development is to obtain insight in the movement restrictions that are reported to have low levels of self-efficacy during activities of daily life. The second goal is to reveal the design needs for an ambulant hip dislocation alert system (HipDas) and the third goal is to explore its usability among patients. Patient-centered experiences with THA were explored by the use of a questionnaire and a semistructured focus group. The questionnaire was administered among n = 32 THA patients at 1 week preoperative and at 3 and 6 weeks postoperative. The questions addressed self-efficacy, performance and effort expectancy, and usefulness and social influence. The focus group consisted of patient journeys and scenario composition. The usability of a prototype version of the HipDas system was evaluated (n = 5). Flexion of the hip >90°, bending over while sitting in a chair, and sleeping in a supine position are the restrictions that have the lowest self-efficacy. The majority of patients (>86.6%) believe that a future HipDas is useful. Focus group outcomes suggest there is a gradual decrease in the threshold for feedback. The system is preferably used in the first 6 weeks after surgery and appeared to be usable and highly clinically relevant. HipDas is considered an interesting concept that can accelerate functional recovery of patients following THA by providing support on how to properly apply postoperative movement restrictions to prevent a dislocation.
Can we prevent hip dislocation in children with cerebral palsy? Effects of postural management.
Picciolini, Odoardo; LE Métayer, Michel; Consonni, Dario; Cozzaglio, Massimo; Porro, Matteo; Gasparroni, Verusca; Panou, Artemisia; Mosca, Fabio; Portinaro, Nicola M
2016-10-01
Hip dislocation is common in children with cerebral palsy (CP). At birth they do not have musculoskeletal deformities but they develop over time due to the combined effects of the movement disorder and impaired gross motor function. Early detection and treatment of a hip at risk is needed to modify the natural of hip development in CP. The aim of this study was to determine the effect of postural management treatment on hip displacement's progression in children CP. Prospective comparative non-randomized study. Rehabilitative outpatient unit. Fifty-one children with CP were studied; the treated group (N.=30) was compared to a control group (N.=21). The treated group followed a two year's long combined treatment program consisting a neurodevelopment treatment (NDT) two times a week and a 5 hours daily siège moulé postural program. The control group underwent only NDT twice a week for two years. Hip radiographs were measured with the migration percentage (MP) method at baseline, at 1 and 2 years of follow-up. A significant difference has been observed in the MP (%) trend (P<0.001) between treatment and control groups. At 2 years, there was a marked worsening (MP from 23.0 to 37.7) in the control group, compared to the stability (from 28.8 to 26.8) in the treatment group. This study supports the evidence that conservative postural management of hip deformity is useful to prevent the natural progression of hip dislocation. Hip radiographic follow up program together with NDT and postural management program is useful to modify the natural progression of hip dislocation in children with CP.
[The hip joint in neuromuscular disorders].
Strobl, W M
2009-07-01
Physiologic motor and biomechanical parameters are prerequisites for normal hip development and hip function. Disorders of muscle activity and lack of weight bearing due to neuromuscular diseases may cause clinical symptoms such as an unstable hip or reduced range of motion. Disability and handicap because of pain, hip dislocation, osteoarthritis, gait disorders, or problems in seating and positioning are dependent on the severity of the disease, the time of occurrence, and the means of prevention and treatment. Preservation of pain-free and stable hip joints should be gained by balancing muscular forces and by preventing progressive dislocation. Most important is the exact indication of therapeutic options such as movement and standing therapy as well as drugs and surgery.
Lampropulos, Mario; Puigdevall, Miguel H; Zapozko, Daniel; Malvárez, Héctor R
2008-01-01
We describe the results obtained with an alternative method of treatment for spastic painful hip dislocations in nonambulatory patients, which consists of a proximal femoral resection with capsular interposition arthroplasty, and the addition of a hinged external fixator for postoperative articulated hip distraction to allow for an immediate upright position and the ability to sit in a wheelchair. We performed this technique in three patients (four hips) with a mean age at the time of surgery of 15 years. Postoperatively, clinical improvement was observed in all four hips, with respect to pain relief, sitting tolerance, perineal care and functional range of motion.
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
Chotai, Pranit N; Ebraheim, Nabil A; Hart, Ryan; Wassef, Andrew
2015-11-05
Constellation of ipsilateral posterior hip dislocation, intertrochanteric- and proximal tibial fracture with popliteal artery injury is rare. Management of this presentation is challenging. A motor vehicle accident victim presented with these injuries, but without any initial signs of vascular compromise. Popliteal artery injury was diagnosed intra-operatively and repaired. This was followed by external fixation of tibial fracture, open reduction of dislocated hip and internal fixation of intertrochanteric fracture. Patient regained bilateral complete weight bearing and returned to pre-accident activity level. Apt surgical management including early repair of vascular injury in such a trauma mélange allows for a positive postoperative outcome.
Dan, Michael; Phillips, Alfred; Simonian, Marcus; Flannagan, Scott
2015-06-01
We provide a review of literature on reduction techniques for posterior hip dislocations and present our experience with a novel technique for the reduction of acute posterior hip dislocations in the ED, 'the rocket launcher' technique. We present our results with six patients with prosthetic posterior hip dislocation treated in our rural ED. We recorded patient demographics. The technique involves placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, in an ergonomically friendly manner for the reducer. We used Fisher's t-test for cohort analysis between reduction techniques. Of our patients, the mean age was 74 years (range 66 to 85 years). We had a 83% success rate. The one patient who the 'rocket launcher' failed in, was a hemi-arthroplasty patient who also failed all other closed techniques and needed open reduction. When compared with Allis (62% success rate), Whistler (60% success rate) and Captain Morgan (92% success rate) techniques, there was no statistically significant difference in the successfulness of the reduction techniques. There were no neurovascular or periprosthetic complications. We have described a reduction technique for posterior hip dislocations. Placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, thus mechanically and ergonomically superior to standard techniques. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Mayer, Stephanie W; Abdo, João Caetano Munhoz; Hill, Mary K; Kestel, Lauryn A; Pan, Zhaoxing; Novais, Eduardo N
2016-09-01
Femoroacetabular impingement (FAI) deformity has been associated with posterior hip instability in adult athletes. To determine if FAI deformity is associated with posterior hip instability in adolescents, the femoral head-neck junction or acetabular structure in a cohort of adolescent patients who sustained a low-energy, sports-related posterior hip dislocation was compared with that in a group of healthy age- and sex-matched controls with no history of hip injury or pain. Cross-sectional study; Level of evidence, 3. We identified 12 male patients (mean age, 13.9 years; range, 12-16 years) who sustained a sports-related posterior hip dislocation and underwent a computed tomography (CT) scan after closed reduction. For each patient, 3 age- and sex-matched healthy controls were identified. Femoral head-neck type was assessed by measurement of the alpha angle on the radially oriented CT images at the 12-, 1-, 2-, and 3-o'clock positions. Age, body mass index (BMI), alpha angle at each position, acetabular version, Tönnis angle, and lateral center-edge angle (LCEA) on the involved hip in the dislocation group were compared with those of the matched controls using a mixed-effects model. A logistic regression analysis using a generalized estimating equation was used to compare the percentage of subjects with cam-type FAI deformity (alpha angle >55°) in each group. The dislocation and control groups were similar in age distribution and BMI (P > .05). The mean alpha angles were statistically significantly higher in the dislocation group compared with the control group at the superior (46.3° ± 1.1° vs 42.7° ± 0.6°; P = .0213), superior-anterior (55.5° ± 1.9° vs 46.0° ± 1.3°; P = .0005), and anterior-superior (54.9° ± 1.5° vs 48.9° ± 1.0°; P = .0045) regions. Cam deformity was present in a larger proportion of patients in the dislocation group than in the control group (P < .0035). An alpha angle greater than 55° was present in 16.7% of the dislocation group and 0% of the control group at the 12-o'clock position (P = .1213), 41.7% versus 0% at the 1-o'clock position (P = .0034), 58% versus 6% at the 2-o'clock position (P = .0004), and 25% versus 2.8% at the 3-o'clock position (P = .0929). Acetabular anteversion was lower in the dislocation group (9.6° ± 1.4°) compared with the control group (15.1° ± 0.8°) (P = .0068). Mean acetabular LCEA was within a normal range in both groups. A significantly higher mean alpha angle from the superior to the anterior-superior regions of the femoral head-neck junction and lower acetabular version were found in adolescents who sustained low-energy, sports-related posterior hip dislocations. © 2016 The Author(s).
Huayamave, Victor; Rose, Christopher; Serra, Sheila; Jones, Brendan; Divo, Eduardo; Moslehy, Faissal; Kassab, Alain J; Price, Charles T
2015-07-16
A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Koch, A; Jozwiak, M; Idzior, M; Molinska-Glura, M; Szulc, A
2015-02-01
We investigated the incidence and risk factors for the development of avascular necrosis (AVN) of the femoral head in the course of treatment of children with cerebral palsy (CP) and dislocation of the hip. All underwent open reduction, proximal femoral and Dega pelvic osteotomy. The inclusion criteria were: a predominantly spastic form of CP, dislocation of the hip (migration percentage, MP > 80%), Gross Motor Function Classification System, (GMFCS) grade IV to V, a primary surgical procedure and follow-up of > one year. There were 81 consecutive children (40 girls and 41 boys) in the study. Their mean age was nine years (3.5 to 13.8) and mean follow-up was 5.5 years (1.6 to 15.1). Radiological evaluation included measurement of the MP, the acetabular index (AI), the epiphyseal shaft angle (ESA) and the pelvic femoral angle (PFA). The presence and grade of AVN were assessed radiologically according to the Kruczynski classification. Signs of AVN (grades I to V) were seen in 79 hips (68.7%). A total of 23 hips (18%) were classified between grades III and V. Although open reduction of the hip combined with femoral and Dega osteotomy is an effective form of treatment for children with CP and dislocation of the hip, there were signs of avascular necrosis in about two-thirds of the children. There was a strong correlation between post-operative pain and the severity of the grade of AVN. ©2015 The British Editorial Society of Bone & Joint Surgery.
Lessons learned from study of congenital hip disease in adults.
Hartofilakidis, George; Lampropoulou-Adamidou, Kalliopi
2016-12-18
Orthopaedic surgeons specialising in adult hip reconstruction surgery often face the problem of osteoarthritis secondary to congenital hip disease (CHD). To achieve better communication among physicians, better treatment planning and evaluation of the results of various treatment options, an agreed terminology is needed to describe the entire pathology. Furthermore, a generally accepted classification of the deformities is necessary. Herein, the authors propose the use of the term "congenital hip disease" and its classification as dysplasia, low dislocation and high dislocation. Knowledge of the CHD natural history facilitates comprehension of the potential development and progression of the disease, which differs among the aforementioned types. This can lead to better understanding of the anatomical abnormalities found in the different CHD types and thus facilitate preoperative planning and choice of the most appropriate management for adult patients. The basic principles for improved results of total hip replacement in patients with CHD, especially those with low and high dislocation, are: Wide exposure, restoration of the normal centre of rotation and the use of special techniques and implants for the reconstruction of the acetabulum and femur. Application of these principles during total hip replacement in young female patients born with severe deformities of the hip joint has led to radical improvement of their quality of life.
A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions.
Herrmann, Sven; Kluess, Daniel; Kaehler, Michael; Grawe, Robert; Rachholz, Roman; Souffrant, Robert; Zierath, János; Bader, Rainer; Woernle, Christoph
2015-01-01
Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients.
A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions
Herrmann, Sven; Kluess, Daniel; Kaehler, Michael; Grawe, Robert; Rachholz, Roman; Souffrant, Robert; Zierath, János; Bader, Rainer; Woernle, Christoph
2015-01-01
Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients. PMID:26717236
Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.
Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long
2015-12-01
Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p < 0.001, respectively). However, there were no significant differences in hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.
Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray
2015-03-01
The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.
Acute iatrogenic dislocation following hip impingement arthroscopic surgery.
Matsuda, Dean K
2009-04-01
This is the first case report of an iatrogenic anterior hip dislocation after arthroscopic surgery for femoroacetabular impingement with over 1 year of follow-up. This case report describes the clinical course of a patient with symptomatic cam-pincer femoroacetabular impingement. She underwent arthroscopic rim trimming, labral debridement after a failed attempt at labral refixation from suture cut-through, and femoral head-neck resection osteoplasty. The procedure involved supranormal hip distraction for extraction of an iatrogenic loose body (detached metallic radiofrequency probe tip). The patient had an anterior hip dislocation in the recovery room. Immediate closed reduction under general anesthesia and bracing were performed but failed despite the ability to obtain a concentric but grossly unstable reduction. After 3 failed attempts, a mini-open capsulorrhaphy was performed that successfully restored stability. Her postoperative management and outcome are presented. All of the major static stabilizers of the hip (osseous, labral, and capsuloligamentous) were surgically altered, and a multifactorial causation is proposed. Lessons learned are discussed in hopes of minimizing the occurrence of this rare but dramatic complication.
Krantz, Nicolas; Miletic, Bruno; Migaud, Henri; Girard, Julien
2012-09-01
Metal-on-metal hip resurfacing is offered as an alternative to traditional hip arthroplasty for young, active adults with advanced osteoarthritis. The concept of hip resurfacing is considered very attractive for this specific population (hard-on-hard bearing component with a large femoral head limiting the risk of dislocation, and allowing femoral bone stock preservation). A prospective clinical trial was designed to investigate the outcome of hip resurfacing in young patients (under 30 years old). We studied 24 hips in 22 patients. Mean age at operation was 24.9 years (range 17.1-29.9). No patient was lost to follow-up. There was no revision at average follow-up of 50.6 months (44-59). Mean UCLA activity score improved from 5.5 (1-9) pre-operatively to 7.6 (1-10) postoperatively (p < 0.001). Mean Harris hip score increased from 43.9 (19-67) to 89.3 (55-100) (p < 0.001). Radiological analysis discerned no osteolysis and no implant migration. The absence of short-term complications, such as mechanical failure or dislocation, is encouraging and leads us to think that mid-term results will be satisfactory. Moreover, the specific advantages of hip resurfacing (bone stock preservation, excellent stability, low risk of dislocation, large-diameter head) make the procedure a very attractive option for young subjects.
Duca, D; Pană, I; Ciovirnache, M; Simionesu, L; Ispas, I; Maxililian, C
1981-01-01
We reported an apparently previously undescribed syndrome, designated the coxoauricular syndrome, in a mother and her 3 daughters, all of whom shared in variable manner shortness of stature, minor vertebral and pelvic changes, dislocated hip(s), and microtia with corresponding hearing loss. The oldest daughter had coincidental Ullrich-Turner syndrome with 46, Xdel(X)(q 13) chromosome constitution. Inheritance of the trait in this family is dominant, either autosomal or X-linked, with hemizygote lethality.
Postural asymmetries in young adults with cerebral palsy.
Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena
2013-11-01
The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Cross-sectional data of 102 people (63 males, 39 females; age range 19-23 y, median 21 y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman's correlation. At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (r(s) =0.48), sitting (r(s) =0.40), standing (r(s) =0.41), and inability to change position: supine (r(s) =0.60), sitting (r(s) =0.73), and standing (r(s) =0.64). Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. © 2013 The Authors. Developmental Medicine & Child Neurology published by John Wiley & Sons Ltd on behalf of Mac Keith Press.
Postural asymmetries in young adults with cerebral palsy
Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena
2013-01-01
Aim The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Methods Cross-sectional data of 102 people (63 males, 39 females; age range 19–23y, median 21y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman’s correlation. Results At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (rs=0.48), sitting (rs=0.40), standing (rs=0.41), and inability to change position: supine (rs=0.60), sitting (rs=0.73), and standing (rs=0.64). Conclusions Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. This article is commented on by Novak on page 974 of this issue. PMID:23834239
[Relevance of MRI After Closed Reduction of Traumatic Hip Dislocation in Children].
Strüwind, Christoph Mauritz; von Rüden, Christian; Thannheimer, Andreas; Bühren, Volker; Schneidmueller, Dorien
2018-05-14
Traumatic hip dislocation in children and adolescents is a rare entity that typically results from high-energy trauma. After closed joint reduction, further treatment depends on the specific pattern of the lesion as identified using cross sectional imaging. The aim of this retrospective analysis was to evaluate relevant side effects after traumatic hip dislocation in children and adolescents in order to examine the need for focused diagnostics. This retrospective analysis covered 8 adolescents under 18 years suffering isolated traumatic hip joint dislocation between 2001 and 2017. In all patients, closed joint reduction was performed immediately after admission to the emergency room. In order to evaluate the complete extent of the injury, 5 patients received an MRI and 3 patients a CT scan following closed joint reduction. Two female and 6 male patients with a median age of 11 (range 5 - 16) years were included. In 2 cases, a free joint body was detected in the posterior joint gap in the posttraumatic CT scan after closed joint reduction. Interposition of the labrum into the joint gap was detected intraoperatively in both cases. In one patient who received posttraumatic MRI, labral interposition into the joint gap was observed after closed reduction. These findings were confirmed intraoperatively. In 4 other patients, no posttraumatic labral lesion was detected in the MRI after closed reduction. The reported side effects included ruptured anterior inferior iliac spine and ruptured femoral head ligament. MRI is gaining increasing importance following traumatic hip dislocation in children and adolescents. A missing chondral or osteochondral fragment in the CT scan does not exclude a labral lesion or interposition. Therefore, MRI following closed reduction is mandatory in any case. Georg Thieme Verlag KG Stuttgart · New York.
Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong
2018-01-08
Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.
Porter, David; Michael, Shona; Kirkwood, Craig
2007-12-01
To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/ dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Cross-sectional observational study. Posture management services in three centres in the UK. Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. A total of 747 participants were included in the study, aged 6-80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P<0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P=0.007), hips subluxed on the left (P=0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P=0.03) were observed. The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed.
Michael, Shona; Kirkwood, Craig
2008-01-01
Objective: To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Design: Cross-sectional observational study. Setting: Posture management services in three centres in the UK. Subjects: Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Main measures: Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. Results: A total of 747 participants were included in the study, aged 6–80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P < 0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P = 0.007), hips subluxed on the left (P = 0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P = 0.03) were observed. Conclusions: The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed. PMID:18042604
Outcomes after salvage procedures for the painful dislocated hip in cerebral palsy.
Wright, Patrick B; Ruder, John; Birnbaum, Mark A; Phillips, Jonathan H; Herrera-Soto, Jose A; Knapp, Dennis R
2013-01-01
The painful dislocated hip in the setting of cerebral palsy is a challenging problem. Many surgical procedures have been reported to treat this condition with varying success rates. The purpose of this study is to retrospectively evaluate and compare the outcomes of 3 different surgical procedures performed at our institution for pain relief in patients with spastic quadriplegic cerebral palsy and painful dislocated hips. A retrospective chart review of the surgical procedures performed by 5 surgeons for spastic, painful dislocated hips from 1997 to 2010 was performed. The procedures identified were (1) proximal femoral resection arthroplasty (PFRA); (2) subtrochanteric valgus osteotomy (SVO) with femoral head resection; and (3) proximal femur prosthetic interposition arthroplasty (PFIA) using a humeral prosthesis. Outcomes based on pain and range of motion were determined to be excellent, good, fair, or poor by predetermined criteria. Forty-four index surgeries and 14 revision surgeries in 33 patients with an average follow-up of 49 months met the inclusion criteria. Of the index surgeries, 12 hips were treated with a PFRA, 21 with a SVO, and 11 with a PFIA. An excellent or good result was noted in 67% of PFRAs, 67% of SVOs, and 73% of PFIAs. No statistical significance between these procedures was achieved. The 14 revisions were performed because of a poor result from previous surgery, demonstrating a 24% reoperation rate overall. No patients classified as having a fair result underwent revision surgery. All patients receiving revision surgery were eventually classified as having an excellent or good result. Surgical treatment for the painful, dislocated hip in the setting of spastic quadriplegic cerebral palsy remains unsettled. There continue to be a large percentage of failures despite the variety of surgical techniques designed to treat this problem. These failures can be managed, however, and eventually resulted in a good outcome. We demonstrated a trend toward better outcomes with a PFIA, but further study should be conducted to prove statistical significance. III.
Primary total hip replacement for displaced subcapital fractures of the femur.
Taine, W H; Armour, P C
1985-03-01
The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.
Sabry, M A; al-Saleh, Q; al-Saw'an, R; al-Awadi, S A; Farag, T I
1995-07-01
A Somali female baby with right upper limb triplication, polythelia, left sided hemihypertrophy, congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis is described. It seems that the above described pattern of anomalies has not been reported before. The possible developmental genetic mechanism responsible for this phenotype is briefly discussed.
Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer
2014-01-01
Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W
2018-04-01
Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing"femur first"principle and combined anteversion techniqueis was (36.6±6.8)°. Also, range of motion of the patients' hip conforms to the D'Lima criterion and no patients had experienced dislocation and some other serious complications.The follow-up ended at August 2017, which lasted for 12.2 months(6-18 months), and 88 cases(119 hips) were interviewed. The Harris hip score for the affected sides of the hip joints 6 months after the surgery was 94.6(86-100). Compared with the score of 29.8(12-43) before surgery, the t -test had proven its statistical significance( t =12.82, P =0.003). Conclusion: Based upon the "femoral first" principle and "combined anteversion technique" during total hip arthroplasty, these operations has been carried out well enough to meet the patients' needs of performing normal daily activities.
Akman, Yunus Emre; Yavuz, Umut; Çetinkaya, Engin; Gür, Volkan; Gül, Murat; Demir, Bilal
2018-03-01
We report the short-term outcomes of total hip arthroplasty(THA) in patients previously treated with Schanz osteotomy (SO). Eighteen patients [2 male, 16 female; mean age, 55.4 (range, 50-66) years] who had undergone THA after SO were retrospectively evaluated. Clinical evaluation was performed based on the Harris hip score. Radiological evaluation was performed using full-length radiographs of the lower extremities, pelvis, and hip. The mean follow-up period was 30.8 (range, 18-56) months. Mean femoral shortening was 3.7 (range, 2-5) cm. Perioperative complications occurred in 4 (22.2%) patients. Nonunion was not found at the osteotomy sites. No dislocation was observed. The Trendelenburg sign was positive for five (27.7%) patients, postoperatively. The mean Harris hip score improved from 42.7 to 78.7 (p < 0.05). THA for hips previously treated with SO is technically demanding. If careful preoperative planning is performed, successful treatment can be achieved.
Screening for developmental dysplasia of the hip.
Desprechins, B; Ernst, C; de Mey, J
2007-01-01
The reported prevalence of established dislocation the hip in an unscreened population varies from 0.7 to 1.6 / 1000 children in European and American white populations. In clinically screened populations neonatal hip instability is reported to occur in 3 to 30 / 1000 newborns while established congenital dislocation has a prevalence of 0.1- 4/1000 of which 1/1000 is judged to be in need for surgery. Early diagnosis of DDH is essential for successful treatment and later prognosis of the disorder. Combined procedure including evaluation of both hip morphology and hip stability is currently recommended. Opinions differ about the need for universal versus selective sonographic screening for diagnosis of DDH. Currently selective screening of those infants with recognised risk factors and those with abnormal physical examination would be cost-effective and the only practicable method for most countries.
Sabry, M A; al-Saleh, Q; al-Saw'an, R; al-Awadi, S A; Farag, T I
1995-01-01
A Somali female baby with right upper limb triplication, polythelia, left sided hemihypertrophy, congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis is described. It seems that the above described pattern of anomalies has not been reported before. The possible developmental genetic mechanism responsible for this phenotype is briefly discussed. Images PMID:7562971
Tins, Bernhard
2011-07-01
Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
[Tripolar arthroplasty for recurrent total hip prosthesis dislocation].
Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H
2003-05-01
The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A revision procedure was necessary for one patient during the 4(th) year because of a fracture of the polyethylene insert on a metal-back cup; the insert alone was changed. Excepting the patient with infection, there were no cases of certain or probable loosening during the follow-up. The tripolar prosthesis with a mobile cup and a large-diameter head appears to be a reliable solution for these severely unstable hips. The procedure can often be limited to the acetabular component, reducing morbidity. The thickness of the polyethylene cup is a limitation which may affect long-term survival. Search for a highly wear-resistant couple continues.
Quantification of Femoral Neck Exposure Through a Minimally Invasive Smith-Petersen Approach
2010-06-01
Gautier E, et al. Surgical dislocation of the adult hip: A technique with full access to femoral head and acetabulum without the risk of avascular ... necrosis . J Bone Joint Surg (Br). 2001;83:1119 1124. 24. Gautier E, Ganz K, Krugel N, et al. Anatomy of the medial femoral circumflex artery and its
Palencia, Jesús; Alfayez, Saud; Serro, Firas; Alqahtani, Jamal; Alharbi, Hani; Alhinai, Hamed
2016-01-01
Femoral head and neck fractures in children are uncommon, accounting for fewer than 1% of all pediatric fractures and fewer than 8% of all hip fractures. Furthermore, traumatic transphyseal hip fracture is rare to present in daily practice especially when associated with an acetabular fracture. A twelve years old boy, not known to have any chronic illnesses, presented to the emergency department as a case of polytrauma after a road traffic accident. Signs of left hip dislocation were discovered upon physical examination. X-rays and CT scans, revealed a complete transphyseal posterior dislocation and a left anterior column fracture of the acetabulum with a minimal displacement. Within five hours, the patient underwent open reduction and internal fixation by two cannulated screws. The acetabular fracture was managed conservatively. After six months, there were clear signs of osteonecrosis of the femoral head. A high-energy trauma in children and adolescents can lead to simultaneous epiphyseal and acetabular fractures which are associated with a poor prognosis. The age seems to play a role as patients older than ten years have a higher risk of developing AVN after sustaining a hip dislocation regardless of the time of intervention. Epiphyseal fracture with dislocation of the femoral head is rare among children and adolescents, especially when associated with an acetabular fracture. AVN in such cases can develop, and it represents a challenge to orthopedic surgeons due to the poor prognosis and the future functional limitations of the joint. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.
Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc
2017-06-01
To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
... dwarfism might have: cleft palate hand and ear differences hip dysplasia club feet severe curvature of the spine early deterioration of joints and joint stiffness potential hip and knee dislocation Complications From Spondyloepiphyseal Dysplasia ...
The anteromedial approach to the psoas tendon in patients with cerebral palsy
Poonnoose, Pradeep M.; Palocaren, Thomas
2007-01-01
Purpose Release of the psoas tendon for flexion deformity of the hip in children with cerebral palsy has traditionally been performed at the pelvic brim, lateral to the neurovascular bundle, or at its insertion into the lesser trochanter. As the psoas tendon is lateral to the pectineus, the traditional exposure of the tendon through an approach medial to the pectineus is limited by the extent to which the pectineus can be retracted proximally. Technical note We describe the use of the anteromedial approach used for the developmentally dislocated hip to expose the psoas tendon between the pectineus and the neurovascular bundle. This provides a much better visualisation of the tendon as it crosses the superior pubic ramus to its insertion. The use of this approach has not been described in cerebral palsy. PMID:19308518
Position of the prosthesis and the incidence of dislocation following total hip replacement.
He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song
2007-07-05
Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.
Sucato, Daniel J; De La Rocha, Adriana; Lau, Karlee; Ramo, Brandon A
2017-03-01
Preoperative Bryant's overhead traction before closed reduction (CR) in developmental dysplasia of the hip (DDH) remains controversial and its success in increasing CR rates and reducing avascular necrosis (AVN) rates has not been specifically reported in a large cohort. IRB-approved retrospective study of patients (below 3 y)who were treated with attempted CR for idiopathic DDH from 1980 to 2009. Successful CR was defined as a hip that remained reduced and did not require repeat CR or open reduction. Patients were grouped by age, hip instability [Ortolani positive (reducible) vs. fixed dislocation], and Tonnis classification and rates of successful CR were compared between groups with P<0.05. A total of 342 hips were included with a mean age of 0.9 years (0.2 to 2.8 y) and a mean follow-up of 10.4 years (2.0 to 27.7 y). There were 269 hips with fixed dislocations and 73 Ortolani-positive hips. Traction was used in 276 hips. There was no difference in traction utilization in the 3 age groups (below 1, below 1.5, and below 2 y) for either Ortolani-positive hips (P=0.947) or fixed dislocations (P=0.943). There was no difference in achieving a successful CR comparing traction (60.9%) and no-traction groups (60.6%) (P=1.00). For Ortolani-positive hips, traction did not improve the incidence of a successful CR for any age group: below 1 year: P=0.19; below 1.5 years: P=0.23; and below 2 years: P=0.25. Similarly, fixed dislocation patients had no benefit from traction: below 1 year: P=0.76; below 1.5 years: P=0.82; and below 2 years: P=0.85. Tonnis classification did predict success of CR but had no influence on traction success. There was no difference in the rate of AVN between the traction (18%) and no-traction (8%) groups for all patients (P=0.15). In this retrospective series, preoperative Bryant's traction does not improve the rate of a successful CR for patients with DDH and has no protective effect on the development of AVN of the femoral head. These results suggest that Bryant's overhead traction may not be warranted for patients below 3 years of age with DDH. Level III.
Alamdaran, Seyed Ali; Kazemi, Sahar; Parsa, Ali; Moghadam, Mohammad Hallaj; Feyzi, Ali; Mardani, Reza
2016-01-01
Background: Developmental dysplasia of hip (DDH) is a common childhood disorder, and ultrasonography examination is routinely used for screening purposes. In this study, we aimed to evaluate a modified combined static and dynamic ultrasound technique for the detection of DDH and to compare with the results of static and dynamic ultrasound techniques. Methods: In this cross-sectional study, during 2013- 2015, 300 high-risk infants were evaluated by ultrasound for DDH. Both hips were examined with three techniques: static, dynamic and single view static and dynamic technique. Statistical analysis was performed using SPSS version 11.5. Results: Patients aged 9 days to 83 weeks. 75% of the patients were 1 to 3 months old. Among 600 hip joints, about 5% were immature in static sonography and almost all of them were unstable in dynamic techniques. 0.3% of morphologically normal hips were unstable in dynamic sonography and 9% of unstable hips had normal morphology. The mean β angle differences in coronal view before and after stress maneuver was 14.43±5.47° in unstable hips. Single view static and dynamic technique revealed that all cases with acetabular dysplasia, instability and dislocation, except two dislocations, were detected by dynamic transverse view. For two cases, Ortolani maneuver showed femoral head reversibility in dislocated hips. Using single view static and dynamic technique was indicative and applicable for detection of more than 99% of cases. Conclusion: Single view static and dynamic technique not only is a fast and easy technique, but also it is of high diagnostic value in assessment of DDH. PMID:27847852
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890... abduction splint is a device intended for medical purposes to stabilize the hips of a young child with...
Lawrey, Emma; Jones, Peter; Mitchell, Robin
2012-04-01
Prosthetic hip dislocation is common. This study compares prosthetic hip relocations attempted within the ED by emergency doctors and those under orthopaedic care in the ED or operating theatre (OT). Retrospective cohort study of patients presenting to Auckland City Hospital Adult Emergency Department with prosthetic hip dislocations between 1 January 2003 and 14 April 2008. Primary outcomes were proportion of successful relocation attempts and length of hospital stay. Secondary outcomes were: time to relocation, complications, post-procedural advice, representation rate and long-term outcomes for first-time dislocations. There were 410 eligible presentations during the study period. Emergency medicine (EM) was successful in 254/323 attempts (79%, 95% confidence interval [CI] 74-83). Orthopaedics were successful in 25/35 reductions in the ED (71%, 95% CI 55-84) and 49/51 OT attempts (96%, 95% CI 86-100), P = 0.004 for location OT versus ED. Median times to discharge were 8.8 h for EM, 28.3 h for orthopaedics in the ED and 81 h for orthopaedics in the OT, P < 0.001 for EM versus orthopaedics. Mechanical complications of procedures and early redislocations were infrequent. Complication of sedation were more often seen in OT compared to ED (23/47 [49%, 95% CI 35-63]vs 37/318 [12%, 95% CI 9-16]). There was no difference between EM and orthopaedics in the proportion of hips successfully relocated or complications in the ED; however, EM patients were discharged much sooner, with important resource implications. Procedures carried out in the OT were more successful than in the ED but resulted in prolonged hospital stays and were associated with more complications. © 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
[Derotational subtrochanteric osteotomy of the femur in celebral palsy patients].
Schejbalová, A
2006-10-01
Derotational subtrochanteric osteotomy as an independent surgical procedure is one of the options for treatment of hip anteversion in adolescent patients with cerebral palsy. In other indications it is one of combined surgical procedures for hip joint reconstruction. During the 1992-2005 period, derotational subtrochanteric osteotomy was indicated in 74 cases, in ambulatory patients 9 to 18 years old, with diplegic or hemiplegic cerebral plasy. In 63 cases it was used a part of combined surgery. The postoperative evaluation was based on clinical and radiographic findings, migration rates and Wiberg's CE angle obtained at 2 and 6 months, and then at each 6 months following surgery. Derotational subtrochanteric osteotomy alone always resulted in improvement of clinical status and an increase in Wiberg's CE angle by 10 degrees on average. Patients with marginal or high dislocation showed best results when the hip joint was reconstructed before the age of 9 years. In three hips a recurrent dislocation occurred gradually within one year of surgery. These patients fell back to stage II of the Vojta classification found preoperatively. During the next three years, three more hips developed a recurrent dislocation and two showed lateralization (20 %). Reconstructive surgery for neurogenic dislocation in patients over 10 years of age is associated with problems, as is derotation combined with varus osteotomy in abductor insufficiency. On the other hand, derotational subtrochanteric osteotomy alone is indicated particularly in children over 10 years, in whom it corrects hip joint anteversion and improves gait. Complete reconstructive procedures should be considered in the first 10 years of life when neither the femoral head nor the acetabulum are markedly changed. Derotative osteotomy alone is preferred to procedures combined with varus osteotomy. In walking adolescent patients, derotative femoral osteotomy alone is recommended; this can exceptionally be used at earlier age if marked asymmetry is present.
Pérez-de la Cruz, S
One of the consequences of poor postural control in children with cerebral palsy is hip dislocation. This is due to the lack of weight-bearing in the sitting and standing positions. Orthotic aids can be used to prevent onset and/or progression. The aim of this study is to analyse the effectiveness of positioning systems in achieving postural control in patients with cerebral palsy, and discuss these findings with an emphasis on what may be of interest in the field of neurology. We selected a total of 18 articles on interventions in cerebral palsy addressing posture and maintenance of ideal postures to prevent deformities and related problems. The main therapeutic approaches employed combinations of botulinum toxin and orthoses, which reduced the incidence of hip dislocation although these results were not significant. On the other hand, using positioning systems in 3 different positions decreases use of botulinum toxin and surgery in children under 5 years old. The drawback is that these systems are very uncomfortable. Postural control systems helps control hip deformities in children with cerebral palsy. However, these systems must be used for prolonged periods of time before their effects can be observed. Copyright © 2015 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
[Effect of abducens orthosis combined with walker on developmental dysplasia of the hip].
Hu, Zhiyong; Xu, Yongqiang; Liang, Jieyu; Li, Kanghua; Liao, Qiande
2009-07-01
To evaluate the effect of abducens orthosis combined with walker on developmental dysplasia of the hip (DDH). A total of 126 patients (224 hips) with DDH aged 6-36 months in Xiangya Hospital was randomly divided into 2 groups: an orthosis combined with walker group and an improved hip frog cast fixation group. Seventy patients (130 hips) were treated by the orthosis combined with walker and 56 patients (94 hips) were treated by the improved hip frog cast fixation. We compared the effect and complications of the 2 groups. The fineness rates of the orthosis combined with walker group and the improved hip frog cast fixation group were 89.2% and 90.4%, respectively, with no significant difference (P>0.05). The rate of femoral head osteonecrosis in the orthosis combined with walker group was significantly lower than that in the improved hip frog cast fixation group (1.5% vs. 5.3%,P<0.05), but the re-dislocation rate in the former was significantly higher than that in the latter (6.9% vs. 1.1 %, P<0.05). Both methods are effective for DDH. Orthosis combined with walker has a lower proportion of femoral head osteonecrosis, but a higher proportion of re-dislocation.
Koczewski, P; Napiontek, M
2001-08-01
We studied 10 patients treated because of late avascular necrosis (AVN) mimicking Legg-Calvé-Perthes' disease (LCPD) after developmental dislocation of the hip (DDH). DDH was recognized late at an average age of 5.4 months and in all children it was treated without surgery. In 4 children, the treatment was complicated by mild AVN of the femoral head, which had disappeared before 3 years of age. The first clinical signs of LCPD were noted at a mean age of 5.8 years. They all had Catterall's type III or IV of LCPD. The course was typical of LCPD. 8 children were operated on at mean age of 7.4 (5-12) years. In 7 of them, subtrochanteric derotation-varisation osteotomy of the femur with shortening combined mainly with Dega's pelvic osteotomy was done. The operative treatment resulted in a concentric position of the femoral head and good coverage of the acetabulum. Follow-ups were done at 10 (6-35) years. Shortened femoral neck and trochanteric overgrowth occurred in 4 operated hips. According to the Stulberg classification, 2 hips were classified as type I, 1 as I/II, 5 as II/I as II/III and 1 as IV. We conclude that LCPD mimicking late AVN can occur in hips treated because of developmental dislocation.
Closed bone graft epiphysiodesis for avascular necrosis of the capital femoral epiphysis.
Thompson, George H; Lea, Ethan S; Chin, Kenneth; Liu, Raymond W; Son-Hing, Jochen P; Gilmore, Allison
2013-07-01
Avascular necrosis (AVN) of the capital femoral epiphysis (CFE) after an unstable slipped capital femoral epiphysis (SCFE), femoral neck fracture or traumatic hip dislocation can result in severe morbidity. Treatment options for immature patients with AVN are limited, including a closed bone graft epiphysiodesis (CBGE). However, it is unclear whether this procedure prevents AVN progression. We investigated whether early MRI screening and CBGE prevented the development of advanced AVN changes in the CFE and the rates of complications with this approach. We prospectively followed all 13 patients (seven boys, six girls) with unstable SCFEs (six patients), femoral neck fractures (five patients), and traumatic hip dislocations (two patients) and evidence of early AVN treated between 1984 and 2012. Mean age at initial injury was 12 years (range, 10-16 years). Nine of the 13 patients had followup of at least 2 years or until conversion to THA (mean, 4.5 years; range, 0.8-8.5 years), including two with unstable SCFEs, the five with femoral neck fractures, and the two with traumatic hip dislocations. All patients had technetium scans and/or MRI within 1 to 2 months of their initial injury (before CBGE) and all had evidence of early (Ficat 0) AVN. Patients were followed clinically and radiographically for AVN progression. Six of the nine hips did not develop typical clinical or radiographic evidence of AVN. These six patients have been followed 6.3 years (range, 4.3-9.1 years) from initial injury and 5.9 years (range, 3.8-8.5 years) from CBGE. The remaining three patients were diagnosed with AVN at periods ranging from 3 to 6 months after CBGE. Early recognition and treatment of AVN with a CBGE may alter the natural history of this complication. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Evaluation and Referral for Developmental Dysplasia of the Hip in Infants.
Shaw, Brian A; Segal, Lee S
2016-12-01
Developmental dysplasia of the hip (DDH) encompasses a wide spectrum of clinical severity, from mild developmental abnormalities to frank dislocation. Clinical hip instability occurs in 1% to 2% of full-term infants, and up to 15% have hip instability or hip immaturity detectable by imaging studies. Hip dysplasia is the most common cause of hip arthritis in women younger than 40 years and accounts for 5% to 10% of all total hip replacements in the United States. Newborn and periodic screening have been practiced for decades, because DDH is clinically silent during the first year of life, can be treated more effectively if detected early, and can have severe consequences if left untreated. However, screening programs and techniques are not uniform, and there is little evidence-based literature to support current practice, leading to controversy. Recent literature shows that many mild forms of DDH resolve without treatment, and there is a lack of agreement on ultrasonographic diagnostic criteria for DDH as a disease versus developmental variations. The American Academy of Pediatrics has not published any policy statements on DDH since its 2000 clinical practice guideline and accompanying technical report. Developments since then include a controversial US Preventive Services Task Force "inconclusive" determination regarding usefulness of DDH screening, several prospective studies supporting observation over treatment of minor ultrasonographic hip variations, and a recent evidence-based clinical practice guideline from the American Academy of Orthopaedic Surgeons on the detection and management of DDH in infants 0 to 6 months of age. The purpose of this clinical report was to provide literature-based updated direction for the clinician in screening and referral for DDH, with the primary goal of preventing and/or detecting a dislocated hip by 6 to 12 months of age in an otherwise healthy child, understanding that no screening program has eliminated late development or presentation of a dislocated hip and that the diagnosis and treatment of milder forms of hip dysplasia remain controversial. Copyright © 2016 by the American Academy of Pediatrics.
Andersson, J E; Odén, A
2001-08-01
The aim of this study was to evaluate the frequency and type of hip-joint instability and the frequency of hip dislocation requiring treatment in neonates who had been lying in the breech presentation and were delivered vaginally after an external version or by caesarean section, and to compare them with neonates who were naturally in the vertex presentation. Breech presentations without ongoing labour were subjected to an attempted external version and, in cases where this proved unsuccessful or where labour had started, to deliver by caesarean section. None of the breech presentations was vaginally delivered. The anterior-dynamic ultrasound method was used to assess the hip-joint status of the neonates. Out of 6,571 foetuses, 257 were in breech presentation after 36 wk of pregnancy. Sixty-two were vaginally delivered following an external version to vertex presentation and 195 were delivered by caesarean section, 75 of these following unsuccessful attempts to perform a version. Treatment for congenital hip-joint dislocation was performed on 0.2%. Out of the breech presentations, 1.0% of those delivered by caesarean section were treated, while in those with vaginal delivery following an external version the treatment frequency was 3.2%. No case of late diagnosed hip dislocation was recorded. Significant differences in frequency of hip-joint instability and treatment were found between (i) neonates delivered in breech presentation and those delivered with vertex presentation, (ii) infants delivered in vertex presentation, naturally or after successful version, and (iii) those delivered by caesarean section with or without attempted external version and those delivered with vortex presentation. Breech presentation predisposes to increased hip instability. The instability is present prior to delivery and is certainly not a primary result of delivery forces. Both breech and vertex presentations following an external or spontaneous version should be considered as risk factors for neonatal hip instability.
Periacetabular Osteotomy Provides Higher Survivorship Than Rim Trimming for Acetabular Retroversion.
Zurmühle, Corinne A; Anwander, Helen; Albers, Christoph E; Hanke, Markus S; Steppacher, Simon D; Siebenrock, Klaus A; Tannast, Moritz
2017-04-01
Acetabular retroversion can cause impaction-type femoroacetabular impingement leading to hip pain and osteoarthritis. It can be treated by anteverting periacetabular osteotomy (PAO) or acetabular rim trimming with refixation of the labrum. There is increasing evidence that acetabular retroversion is a rotational abnormality of the entire hemipelvis and not a focal overgrowth of the anterior acetabular wall, which favors an anteverting PAO. However, it is unknown if this larger procedure would be beneficial in terms of survivorship and Merle d'Aubigné scores in a midterm followup compared with rim trimming. We asked if anteverting PAO results in increased survivorship of the hip compared with rim trimming through a surgical hip dislocation in patients with symptomatic acetabular retroversion. We performed a retrospective, comparative study evaluating the midterm survivorship of two matched patient groups with symptomatic acetabular retroversion undergoing either anteverting PAO or acetabular rim trimming through a surgical hip dislocation. Acetabular retroversion was defined by a concomitantly present positive crossover, posterior wall, and ischial spine sign. A total of 279 hips underwent a surgical intervention for acetabular retroversion at our center between 1997 and 2012 (166 periacetabular osteotomies, 113 rim trimmings through surgical hip dislocation). A total of 99 patients (60%) were excluded from the PAO group and 56 patients (50%) from the rim trimming group because they had any of several prespecified conditions (eg, dysplasia or pediatric conditions 61 [37%] for the PAO group and two [2%] for the rim trimming group), matching (10 [6%]/10 [9%] hips), deficient records (10 [6%]/13 [12%] hips), or the patient declined or was lost to followup (18 [11%]/31 [27%] hips). This left 67 hips (57 patients) that underwent anteverting PAO and 57 hips (52 patients) that had acetabular rim trimming. The two groups did not differ in terms of age, sex, body mass index, preoperative ROM, preoperative Merle d'Aubigné-Postel score, radiographic morphology of the acetabulum (except total and anterior acetabular coverage), alpha angle, Tönnis grade of osteoarthritis, and labral and chondral lesions on the preoperative MRI. During the period in question, we generally performed PAO from 1997 to 2003. With the availability of surgical hip dislocation and labral refixation, we generally performed rim trimming from 2004 to 2010. With growing knowledge of the underlying pathomorphology, anteverting PAOs became more common again around 2007 to 2008. A minimum followup of 2 years was required for this study. Failures were included at any time. The median followup for the anteverting PAO group was 9.5 years (range, 2-17.4 years) and 6.8 years (range, 2.2-10.5 years) for the rim trimming group (p < 0.001). Kaplan-Meier survivorship analysis was performed using the following endpoints at 5 and 10 years: THA, radiographic progression of osteoarthritis by one Tönnis grade, and/or Merle d'Aubigné-Postel score < 15 points. Although the 5-year survivorship of the two groups was not different with the numbers available (86% [95% confidence interval {CI}, 76%-94%] for anteverting PAO versus 86% [95% CI, 76%-96%] for acetabular rim trimming), we found increased survivorship at 10 years in hips undergoing anteverting PAO for acetabular retroversion (79% [95% CI, 68%-90%]) compared with acetabular rim trimming (23% [95% CI, 6%-40%]) at 10 years (p < 0.001). The drop in the survivorship curve for the acetabular rim trimming through surgical hip dislocation group started at Year 6. The main reason for failure was a decreased Merle d'Aubigné score. Anteverting PAO may be the more appropriate treatment for hips with substantial acetabular retroversion. This may be the result of reduction of an already smaller lunate surface of hips with acetabular retroversion through rim trimming. However, rim trimming may still benefit hips with acetabular retroversion in which only one or two of the three signs are positive. Future randomized studies should compare these treatments. Level III, therapeutic study.
Stability of the Giliberty bipolar hip: report of three cases.
Langan, P; Weiss, C A
1978-01-01
The Giliberty Bipolar Hip Prosthesis consists of an unbonded acetabular cup which snap-fits over the head of the femoral prosthesis. Because of the free movement permitted at the cup-pelvic junction as well as at the snap-fit interface, there has been a great deal of concern over the potential for dislocation. Three patients in whom this unit was implanted sustained significant skeletal trauma subsequent to surgery. None of them dislocated. In each case the prosthetic head was known to be in a relatively vertical orientation with respect to the transverse axis of the pelvis prior to the injury. In 2 of the 3 cases radiographically identifiable movement of the cup was present before and after the injury. These observations suggest that the persistently mobile, vertically positioned unbonded cup remain stable despite the stress of significant trauma. It is probable that the potential for cup movement, even where on the X-ray it appears to have stopped, acts as a safety valve in absorbing force that might otherwise dislocate the hip or cause fractures of the femur or the pelvis.
Abdel, Matthew P; von Roth, Philipp; Jennings, Matthew T; Hanssen, Arlen D; Pagnano, Mark W
2016-02-01
Numerous factors influence total hip arthroplasty (THA) stability including surgical approach and soft tissue tension, patient compliance, and component position. One long-held tenet regarding component position is that cup inclination and anteversion of 40° ± 10° and 15° ± 10°, respectively, represent a "safe zone" as defined by Lewinnek that minimizes dislocation after primary THA; however, it is clear that components positioned in this zone can and do dislocate. We sought to determine if these classic radiographic targets for cup inclination and anteversion accurately predicted a safe zone limiting dislocation in a contemporary THA practice. From a cohort of 9784 primary THAs performed between 2003 and 2012 at one institution, we retrospectively identified 206 THAs (2%) that subsequently dislocated. Radiographic parameters including inclination, anteversion, center of rotation, and limb length discrepancy were analyzed. Mean followup was 27 months (range, 0-133 months). The majority (58% [120 of 206]) of dislocated THAs had a socket within the Lewinnek safe zone. Mean cup inclination was 44° ± 8° with 84% within the safe zone for inclination. Mean anteversion was 15° ± 9° with 69% within the safe zone for anteversion. Sixty-five percent of dislocated THAs that were performed through a posterior approach had an acetabular component within the combined acetabular safe zones, whereas this was true for only 33% performed through an anterolateral approach. An acetabular component performed through a posterior approach was three times as likely to be within the combined acetabular safe zones (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.1-1.6) than after an anterolateral approach (OR, 0.4; 95% CI, 0.2-0.7; p < 0.0001). In contrast, acetabular components performed through a posterior approach (OR, 1.6; 95% CI, 1.2-1.9) had an increased risk of dislocation compared with those performed through an anterolateral approach (OR, 0.8; 95% CI, 0.7-0.9; p < 0.0001). The historical target values for cup inclination and anteversion may be useful but should not be considered a safe zone given that the majority of these contemporary THAs that dislocated were within those target values. Stability is likely multifactorial; the ideal cup position for some patients may lie outside the Lewinnek safe zone and more advanced analysis is required to identify the right target in that subgroup. Level III, therapeutic study.
Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D
2015-01-01
In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.
Hip Surveillance in Children with Cerebral Palsy.
Huser, Aaron; Mo, Michelle; Hosseinzadeh, Pooya
2018-04-01
The hip is the second most common involved joint in cerebral palsy. Hip displacement occurs in more than 33% of children with cerebral palsy, with a higher prevalence in nonambulatory children. Hip displacement in this population is typically progressive. Hip dislocation can result in pain and difficulty with sitting and perineal care. Since early stage of hip displacement can be silent, and hip surveillance programs are recommended. Most programs use the degree of hip dysplasia and Growth Motor Function Classification System level for screening recommendations. Treatment depends on the degree of dysplasia, functional status of the patient, and patient's age. Copyright © 2017 Elsevier Inc. All rights reserved.
Inoue, Daisuke; Kajino, Yoshitomo; Taga, Tadashi; Yamamoto, Takashi; Takagi, Tomoharu
2018-01-01
Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis. PMID:29666733
[Intra-prosthetic dislocation of the Bousquet dual mobility socket].
Lecuire, F; Benareau, I; Rubini, J; Basso, M
2004-05-01
The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk of dislocation or a chronically unstable hip prosthesis. Careful technique is required to reduce or retard the risk of intra-prosthetic dislocation. Intra-prosthetic dislocation of a dual mobility socket is an exceptional complication at mid-term. Surgical treatment is required but may be limited to simple insert replacement. Systematic use of this type of implant in young subjects must be carefully examined, but for us, the risk of dislocation does not outweigh the advantages of this original concept of dual mobility. This type of socket remains an useful preventive technique for high-risk hips or for curative treatment of recurrent dislocation.
Early results of one-stage correction for hip instability in cerebral palsy.
Kim, Hui Taek; Jang, Jae Hoon; Ahn, Jae Min; Lee, Jong Seo; Kang, Dong Joon
2012-06-01
We evaluated the clinical and radiological results of one-stage correction for cerebral palsy patients. We reviewed clinical outcomes and radiologic indices of 32 dysplastic hips in 23 children with cerebral palsy (13 males, 10 females; mean age, 8.6 years). Ten hips had dislocation, while 22 had subluxation. Preoperative Gross Motor Function Classification System (GMFCS) scores of the patients were as follows; level V (13 patients), level IV (9), and level III (1). Acetabular deficiency was anterior in 5 hips, superolateral in 7, posterior in 11 and mixed in 9, according to 3 dimensional computed tomography. The combined surgery included open reduction of the femoral head, release of contracted muscles, femoral shortening varus derotation osteotomy and the modified Dega osteotomy. Hip range of motion, GMFCS level, acetabular index, center-edge angle and migration percentage were measured before and after surgery. The mean follow-up period was 28.1 months. Hip abduction (median, 40°), sitting comfort and GMFCS level were improved after surgery, and pain was decreased. There were two cases of femoral head avascular necrosis, but no infection, nonunion, resubluxation or redislocation. All radiologic indices showed improvement after surgery. A single event multilevel surgery including soft tissue, pelvic and femoral side correction is effective in treating spastic dislocation of the hip in cerebral palsy.
Current Concepts in Hip Preservation Surgery
Adler, Kelly L.; Cook, P. Christopher; Geisler, Paul R.; Yen, Yi-Meng; Giordano, Brian D.
2016-01-01
Context: Successful treatment of nonarthritic hip pain in young athletic individuals remains a challenge. A growing fund of clinical knowledge has paralleled technical innovations that have enabled hip preservation surgeons to address a multitude of structural variations of the proximal femur and acetabulum and concomitant intra-articular joint pathology. Often, a combination of open and arthroscopic techniques are necessary to treat more complex pathomorphologies. Peri- and postoperative recovery after such procedures can pose a substantial challenge to the patient, and a dedicated, thoughtful approach may reduce setbacks, limit morbidity, and help optimize functional outcomes. Evidence Acquisition: PubMed and CINAHL databases were searched to identify relevant scientific and review articles through December 2014 using the search terms hip preservation, labrum, surgical dislocation, femoroacetabular impingement, postoperative rehabilitation, peri-acetabular osteotomy, and rotational osteotomy. Reference lists of included articles were reviewed to locate additional references of interest. Study Design: Clinical review. Level of Evidence: Level 4. Results: Hip preservation procedures and appropriate rehabilitation have allowed individuals to return to a physically active lifestyle. Conclusion: Effective postoperative rehabilitation must consider modifications and precautions specific to the particular surgical techniques used. Proper postoperative rehabilitation after hip preservation surgery may help optimize functional recovery and maximize clinical success and patient satisfaction. PMID:26733593
[New classification of Crowe type IV developmental dysplasia of the hip].
Ma, Hai-yang; Zhou, Yong-gang; Zheng, Chong; Cao, Wen-zhe; Wang Sen; Wu, Wen-ming; Piao, Shang; Du, Yin-qiao
2016-02-01
To compare differences between Crowe IV developmental dysplasia of the hip (DDH) with secondary acetabulum and Crowe IV DDH without secondary acetabulum,and determine whether it is necessary to divide Crowe IV DDH into two subtypes. From June 2007 to May 2015,145 hips of 112 Crowe N patients who underwent total hip arthroplasty (THA) using S-ROM stem were divided into two groups: secondary acetabulum formaton group (group A) and no secondary acetabulum formaton group (group B). In group A,there were 12 females, 96 males,with an average age of (39.38 ± 11.19) years old. In group B, there were 2 females, 35 males, with an average age of (38.19 ± 10.92) years old. All the patients were evaluated by using Harris Hip Score. Radiographic evaluations were made preoperatively and during follow up. The differences between two groups were compared on dislocation height, canal flare index (CFI), subtrochanteric shortening osteotomy (SSTO) usage, pre- and post-operation Harris scores, complications. The dislocation height for group A was (4.74 ± 1.57) cm, while the dislocation height for group B was (3.12 ± 1.15) cm. Significantly difference was detected between two groups. The CFI for group A was 2.69 ± 0.68, while the CFI for group B was 3.42 ± 0.79, and the significantly difference was detected between two groups. Harris scores were totally improved from 58.18 ± 15.67 preoperatively to 91.20 ± 3.79 post-operatively and the difference was significant. Pre-operative Harris scores was 58.1 ± 15.3 in group A, 58.3 ± 16.9 in group B. Post-operative Harris scores was 91.0 ± 4.1 in group A, 91.0 ± 5.1 in group B. No significant difference was found on Harris scores between A and B preoperatively and post-operatively. Complications of 4 cases peri-prosthesis fracture, 4 cases dislocation and 4 cases nerve injury occur in group A; While only one case dislocation and one case nerve injury occur in group B. No statistical significance was detected. Crowe IV DDH with secondary acetabulum is significantly different from Crowe IV DDH without secondary acetabulum on dislocation height and femoral morphology, which causes the different selections of surgical techniques (SSTO usage or not). These important differences in fundamental parameters indicate the necessity to further divide Crowe IV DDH into IVA and IVB two subtypes.
Bhatti, Anisuddin; Jamali, A R; Mehboob, Ghulam
2009-01-01
This study was conducted to assess the effect of age on the ultimate outcome measures following single stage surgical procedure of soft tissue release, relocation, capsulorrhaphy, femoral shortening with varus/derotation osteotomy and pelvic osteotomy. A case series. The study with two groups of pretest-posttest design was conducted at Department of Orthopaedic Surgery, Jinnah Postgraduate Medical Centre (JPMC), Karachi, from 1993 to January 2008. Patients included were having neglected, congenital dislocation of the hip joint, aged over 3 years. Patients with failed previous surgery, paralytic, teratological, traumatic or septic dislocations and patients with less than 5 years follow-up were excluded from the study. The patients were divided into two groups, 3-7 years (37 hip joints) and over 7 years (13 hip joints). The single stage surgical procedure of open relocation, femoral shortening/derotation/ varus osteotomy and pelvic osteotomy was the dependent variable; whereas, the final clinico-radiological results based upon Tonnis grading, Severin's clinical/radiological grading, Klisic's overall rating and acetabular index were the independent variables of the study. Pre- and postoperative data was assessed for overall improvement and the difference in outcome measures between the two age groups. Significant overall improvement on all parameters was achieved after surgery. When results were compared between two age groups, there was no significant difference in the final outcome as per Tonnis grading and Severin's clinical typing as modified by Gibson (97.3% versus 84.4% normal hip joints or Tonnis grade 1 and 78.37% versus 53.85% Severin's type 1) but the results based upon Severin's radiological grading (62.16% versus 15.38%) and Klisic's overall rating (62.16% versus 15.38%) were significantly better in 3-7 years as compared to those over 7 years. There was no significant difference between the two age groups when compared for improvement in acetabular index. On further analysis, a progressive deterioration of results with increasing age was observed, yet the results in those aged over 7 years were reasonably justified surgical correction of congenital dislocation of the hip joint. Majority of the complications were seen in children operated at the age of 4-5 years. There were 7 cases (14%) of redislocation/subluxation and 6 were in 3-7 years age group. There were 4 cases (8%) of the avascular necrosis of the femoral head. Three patients had residual coxa vara and 2 had significant limb shortening. Limb lengthening was done in these 2 cases. The final results displayed progressive deterioration of clinical, radiological and functional outcome measures with aging after single stage reconstructive surgery for the congenital dislocation of hip joint. However, despite this, the results in children over 7 years were also good/excellent in most of the cases justifying surgery.
Gekeler, Jörg
2007-10-01
AIMS OF DIAGNOSTIC RADIOGRAPHY: Visualization of the proximal femur in two clearly defined projections. Radiologic and morphological diagnosis of slipped capital femoral epiphysis. Evaluation of the stability of the femoral epiphysis: chronic slippage or acute interruption of continuity between the femoral epiphysis and the femoral neck metaphysis. Radiometric measurement of the spatial deformity of the femoral epiphysis. Measurement of the projected epiphyseal angle on the radiograph as the basis for possible conversion into anatomically correct angles at the proximal femur. Preoperative planning of therapeutic surgical procedures. Idiopathic hip pain in the growing child or adolescent. Referred pain to the knee or thigh. Unusual gait pattern with external rotation deformity of the leg, limping that favors one leg or limping due to leg length discrepancy. Abnormal sonography, CT or MRI findings. Eventful history including minor injury or genuine trauma. Symptoms and uncommon physical constitution: obesity, exceptional longitudinal growth of the extremities, and absence of secondary sex characteristics. Indications for Radiographic Imaging of the Hip Joint in Two Planes None. Standard positioning of the patient or the affected extremity. First standard radiograph: proximal femur in anteroposterior projection. Position of the leg with the patella directed anteriorly. Contraction of the external rotators at the hip joint is compensated by elevation of the hip until the leg is in the neutral position. Second standard radiograph: axial view of the proximal femur in anteroposterior projection. Leg flexed to 90 degrees at the hip and in 45 degrees abduction. Thigh position parallel to the longitudinal axis of the table (zero rotation). Early signs of incipient or imminent femoral epiphyseolysis: --Disintegration, widening and blurred margins of the epiphyseal plate. --Increasing loss of height of the femoral epiphysis due to incipient dislocation. --The tangent to the lateral femoral neck intersects only slightly with the femoral head or runs tangential to the epiphysis. --Important second radiograph in axial projection: incipient slippage is seen early here. Comparison with the contralateral side. Chronic slipped capital femoral epiphysis in adolescents: --Advanced epiphyseal dislocation visible in both planes. The tangent to the lateral femoral neck no longer intersects with the dislocated femoral epiphysis. In some cases, varus deformity of the femoral neck and periosteal elevation at the borders of the medial femoral neck. --Epiphyseal dislocation even more apparent in the axial view. Acute slipped capital femoral epiphysis in adolescents: --Complete interruption of continuity between epiphysis and metaphysis. --Widened gap between epiphysis and metaphysis. --Cystic irregularities of the metaphysis. --In most cases, substantial dislocation between epiphysis and metaphysis. --"Acute on chronic slip": specific type of acute epiphyseal dislocation subsequent to chronic epiphyseolysis. In addition to signs of acute separation, secondary symptoms of chronic epiphyseolysis such as femoral neck arcuation and spur formation at the head-neck junction. --Dynamic fluoroscopy may be indicated to confirm acute dislocation. Defined axes are marked on the radiograph: anatomic axis of the femur, femoral neck axis, and so-called epiphyseal axis (perpendicular to the base of the epiphysis). Measurement of the projected epiphysis-diaphysis angle (ED' angle) on the anteroposterior radiograph and the projected epiphyseal torsion angle (ET' angle) on the axial radiograph. For slight to moderate slippage, the difference between the epiphyseal dislocation angle obtained from the radiographs (as projected in two planes) compared with the anatomic, i.e., real dislocation angle at the proximal femur is generally relatively minor. Conversion of the projected angle to the real angle is not essential in these cases (if in doubt, see Table 1). For more severe dislocations, the differences between the projected and real angles are far more apparent. Table 1 facilitates conversion of the epiphyseal dislocation angles taken from the radiograph into anatomically correct dislocation angles at the proximal femur. Conversion to real angles, especially for preoperative planning of complex corrective surgery, is indicated for more severe deformities of the femoral epiphysis. Conversion into real (anatomic) angles is indicated for exact prognostic evaluation of prearthrotic deformities.
Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H
2017-03-01
To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.
HiL simulation in biomechanics: a new approach for testing total joint replacements.
Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer
2012-02-01
Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Fousek, J; Indráková, P
2007-02-01
The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides better covering of the cup with solid bone, without the necessity of cotyloplasty or structural graft use. Also, it does not markedly affect hip function or patients' subjective feelings.
Saragaglia, D; Belvisi, B; Rubens-Duval, B; Pailhé, R; Rouchy, R C; Mader, R
2015-06-01
Large-diameter metal-on-metal hip prostheses are no longer used, but their outcomes after more than 5 years are unknown. We conducted a retrospective study with a 6.8-year mean follow-up to assess clinical outcomes after Durom™ cup implantation, including the dislocation rate, comparatively to the reference metal-on-polyethylene bearing. We determined the rate of failure ascribable to Durom™ cup use. We also looked for a sharp drop in the implant survival curve during the follow-up period and for factors associated with adverse reactions to metal debris (ARMDs). We hypothesised that clinical outcomes after Durom™ cup implantation were similar to those seen with a metal-on-polyethylene bearing, except for a lower rate of dislocation. We included 177 consecutive THA procedures that were performed between 2005 and 2008 in 165 patients with a mean age of 57.6 ± 9.4 years (range, 31-76 years) and involved the implantation of a Durom™ cup, a femoral head greater than 36mm in diameter, and a PF(®) femoral stem (Zimmer, Etupes, France). The mini-posterior approach was used, with 2mm of acetabular overreaming in 82% of cases, a short femoral neck in 75% of cases, and a mean cup inclination of 34 ± 5° (range, 21-50°). Outcomes were assessed for 156 THA procedures in 146 patients after a mean follow-up of 6 years 8 months. The mean Postel-Merle d'Aubigné score improved from 9.7 ± 2.7 (range, 4-14) to 17.4 ± 1.7 (range, 15-18) and the mean Harris hip score from 45.2 ± 15.3 (range, 9-83) to 96.3 ± 7 (75-100). No episodes of dislocation were recorded. We identified 7 failures ascribable to the Durom™ cup including 6 due to ARMD and 1 to aseptic loosening. Implant survival after a mean of 80months was 95.5% (95% CI, 93.1-99.2), with no sharp drop in the survival curve. The Durom™ cup eliminates the risk of hip dislocation and produces similar functional outcomes to those seen with metal-on-polyethylene bearings after a mean follow-up of 80 months. Nevertheless, given the difficulty in predicting ARMD and hypersensitivity reactions, the Durom™ cup has been discarded and patients carrying it are monitored closely. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Gallart, X; Gomez, J C; Fernández-Valencia, J A; Combalía, A; Bori, G; García, S; Rios, J; Riba, J
2014-01-01
To evaluate the short-term results of an ultra high molecular weight polyethylene retentive cup in patients at high risk of dislocation, either primary or revision surgery. Retrospective review of 38 cases in order to determine the rate of survival and failure analysis of a constrained cemented cup, with a mean follow-up of 27 months. We studied demographic data, complications, especially re-dislocations of the prosthesis and, also the likely causes of system failure analyzed. In 21.05% (8 cases) were primary surgery and 78.95% were revision surgery (30 cases). The overall survival rate by Kaplan-Meier method was 70.7 months. During follow-up 3 patients died due to causes unrelated to surgery and 2 infections occurred. 12 hips had at least two previous surgeries done. It wasn't any case of aseptic loosening. Four patients presented dislocation, all with a 22 mm head (P=.008). Our statistical analysis didn't found relationship between the abduction cup angle and implant failure (P=.22). The ultra high molecular weight polyethylene retentive cup evaluated in this series has provided satisfactory short-term results in hip arthroplasty patients at high risk of dislocation. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng
2013-07-01
To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.
Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H
2017-05-03
Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components. Economic and decision analysis Level III. See Instructions for Authors for a complete description of levels of evidence.
The effect of soft tissue release of the hips on walking in myelomeningocele.
Correll, J; Gabler, C
2000-06-01
Walking and standing capacity in myelomeningocele is highly dependent on the level of the neurological lesion. Deformities, mainly flexion deformities, of the hip can severely interfere with mobility. In a retrospective study, undertaken in our hospital, we evaluated the role of soft tissue release of the hip in patients with hip flexion contractures. A special surgical technique was performed in 55 hips. The results show a good effect on verticalization, even if the hip joints cannot be extended actively. A subluxated or dislocated hip did not influence the final outcome. During the mean follow-up of approximately 4 years, only a slight recurrence of the former deformity was observed. Most of the patients obtained great advantage from the operation.
Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.
Assi, Chahine; El-Najjar, Elie; Samaha, Camille; Yammine, Kaissar
2017-03-01
Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.
Schaeffer, Emily K; Study Group, Ihdi; Mulpuri, Kishore
2018-05-07
There is a lack of high quality evidence available to guide clinical practice in the treatment and management of developmental dysplasia of the hip (DDH). Evidence has been limited by persistent confusion on diagnostic and classification terminology, variability in surgeon decision making and a reliance on single centre, retrospective studies with small patient numbers. To address gaps in knowledge regarding screening, diagnosis and management of DDH, the International Hip Dysplasia Institute began a multicentre, international prospective study on infants with hips dislocated at rest. This review discusses the current state of screening, diagnostic and management practices in DDH and addresses important unanswered questions that will be critical in identifying best practices and optimising patient outcomes. There is insufficient evidence to support universal ultrasound screening; instead, selective screening should be performed by 6-8 weeks of age on infants with risk factors of breech presentation, family history, or history of clinical hip instability. Follow-up of infants with risk factors and normal initial screening should be considered to at least 6 months of age. Brace treatment is a sensible first-line treatment for management of dislocated hips at rest in infants < 6 months of age. Early operative reduction may be considered as there is insufficient evidence to support a protective role for the ossific nucleus in the development of avascular necrosis.
Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model
Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D
2004-01-01
Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198
1997 Accession Medical Standards Analysis & Research Activity (AMSARA) Annual Report
1998-05-01
3.7 Hip Dental 13 2.8 Hip dislocation 44 2.1 Injury-lower 11 2.4 Foot-ankle 41 1.9 extremities Prior knee surgery .7 1.5 Curvature of the spine 35...Genetic Influences in Childhood-Onset Psychiatric Disorders: Autism and Attention-Deficit/Hyperactivity Disorder. Am J Hum Genet 1997;60:1276-1282
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi
2013-12-01
Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi
2013-01-01
Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146
Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability
Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Béjui-Hugues, Jacques
2008-01-01
Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2–6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18780135
Ning, Bo; Yuan, Yi; Yao, Jie; Zhang, Sichng; Sun, Jun
2014-11-28
The one-stage procedure for treatment of older developmental dislocation of the hip (DDH) is used widely. However, the best age group for this operation is still unknown. The aims of our study were to evaluate middle-term outcomes of one-stage surgical treatment of a large number of patients with late-diagnosed DDH, and to explore the best age group for treatment. We retrospectively reviewed 652 patients with a total of 864 hip joints with DDH, all aged >18 months. All the hip joints were treated with one-stage procedures including open reduction, pelvic osteotomy, and femoral shortening. The patients were divided into three groups according to age at surgery: Group I: 1.5-2.5 years; Group II: 2.5-8 years; and Group III: >8 years. The latest clinical and radiographic outcomes, complications and avascular necrosis (AVN) of the femoral head were evaluated and compared among the three groups. The mean age at surgery was 5.8 years (range: 1.5-13.2 years). The average time of follow-up was 6.2 years (range: 3.2-8.9 years). A total of 79.4% of good or excellent outcomes were obtained for clinical functional evaluation according to the McKay classification. For radiographic outcomes, 732 hips (84.7%) were classified as good or excellent according to the Severin classification. A total of 27.4% of all hips had a poor outcome according to the Kalamchi and MacEwen classification for AVN. The poorest outcomes were observed for clinical, radiographic and AVN results in Group III (p < 0.001). Compared with Group I, the better results for clinical and AVN outcomes were found in Group II (p < 0.001). However, similar clinical outcomes were observed between Groups I and II (p > 0.05). A significantly higher incidence of redislocation and residual acetabular dysplasia was observed in Tonnis grade II and III hip dislocation (p < 0.001). One-stage treatment of late-diagnosed DDH had a good outcome in young and middle group. Younger patients achieved better results than older patients. However, the best age group was 2.5-8 years. Tonnis grade II and III DDH is a risk factor for redislocation and residual acetabular dysplasia after the one-stage operation.
Congenital Dislocation of the Hip
Specht, Elmer E.
1976-01-01
Congenital dislocation or subluxation of the hip (congenital acetabular dysplasia) is a complete or partial displacement of the femoral head out of the acetabulum. The physical signs essential for diagnosis are age related. In newborns the tests for instability are the most sensitive. After the neonatal period, and until the age of walking, tightness of the adductor muscles is the most reliable sign. Early diagnosis is vital for successful treatment of this partially genetically determined condition. Various therapeutic measures, ranging from abduction splinting to open reduction and osteotomy, may be required. Following diagnosis in the first month of life, the average treatment time in one recent series was only 2.3 months from initiation of therapy to attainment of a normal hip. When the diagnosis was not made until 3 to 6 months of age, ten months of treatment was required to achieve the same outcome. When the diagnosis is not made, or the treatment is not begun until after the age of 6, a normal hip will probably not develop in any patient. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9. PMID:1251603
Cement-in-cement acetabular revision with a constrained tripolar component.
Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan
2012-02-17
Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.
Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.
Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S
2017-10-01
As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.
Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong
2016-01-01
We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.
Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.
2011-01-01
Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701
Ozden, V Emre; Dikmen, G; Beksac, B; Tozun, I Remzi
2017-06-01
The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Natural substrate lift-off technique for vertical light-emitting diodes
NASA Astrophysics Data System (ADS)
Lee, Chia-Yu; Lan, Yu-Pin; Tu, Po-Min; Hsu, Shih-Chieh; Lin, Chien-Chung; Kuo, Hao-Chung; Chi, Gou-Chung; Chang, Chun-Yen
2014-04-01
Hexagonal inverted pyramid (HIP) structures and the natural substrate lift-off (NSLO) technique were demonstrated on a GaN-based vertical light-emitting diode (VLED). The HIP structures were formed at the interface between GaN and the sapphire substrate by molten KOH wet etching. The threading dislocation density (TDD) estimated by transmission electron microscopy (TEM) was reduced to 1 × 108 cm-2. Raman spectroscopy indicated that the compressive strain from the bottom GaN/sapphire was effectively released through the HIP structure. With the adoption of the HIP structure and NSLO, the light output power and yield performance of leakage current could be further improved.
Hip Dislocation and Dystocia in Early Medieval Times: Possible Evidence of Labor Maneuver.
Malgosa, Assumpció; Carrascal, Susana; Piga, Giampaolo; Isidro, Albert
2016-12-01
In ancient times, maternal mortality would occur frequently, particularly during labor. Evidence of dystocia resulting in the death of a pregnant woman is very infrequent in paleopathologic literature, with only a few cases being demonstrated. In the early medieval site of Casserres, the skeleton of a young woman with a fetus in the pelvic region was found. Some abnormal findings of the maternal skeleton were evaluated, including a sacral anomaly, femoral head wound, the rare position of the lower left limb with the femoral head dislodged anteriorly and cephalad from the socket, and a fibular fracture. Examining the anomalies all together, a case of anterior hip dislocation related to a McRoberts-like maneuver performed during labor is a plausible explanation of the findings.
Hoenig, L J
1997-02-01
This study describes in modern medical terms a traumatic hip injury suffered by the Biblical patriarch Jacob approximately 3,500 years ago. The case history is based on the original Hebrew text found in the Bible book of Genesis (Chapter 32:25-33) as interpreted by traditional Jewish commentaries on the Bible. Jacob sustained a hip injury in hand-to-hand combat with an adversary or through an intense physiological reaction to a prophetic vision of such a battle. He appears to have sustained neurological injury to his sciatic nerve as well as musculoskeletal damage to his hip. These injuries caused a temporary limping gait. Jacob probably sustained a neurapraxia of the sciatic nerve. The differential diagnosis of his musculoskeletal hip injury includes hip dislocation, fracture, soft tissue trauma, and articular pathology.
Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.
Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young
2016-06-01
For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic stability and morphology, although 71% of hips with major instability showed normal or immature morphology according to static ultrasound examination, the coefficient was as high as 0.64. Discrepancies between clinical and ultrasound examinations were present even if almost all of the exams were performed by a single experienced pediatric orthopedic surgeon. In relation to screening for DDH, it is recommended that both sonographic morphology and stability be checked in addition to clinical examination.
Gonzalez, Amanda Inez; Bartolone, Placido; Lubbeke, Anne; Dupuis Lozeron, Elise; Peter, Robin; Hoffmeyer, Pierre; Christofilopoulos, Panayiotis
2017-02-01
Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.
Report of a new case and clinical delineation of mosaic trisomy 9 syndrome
Sánchez, José María; Fijtman, Nora; Migliorini, Ana María
1982-01-01
A newborn girl with trisomy 9 mosaicism is reported. Clinical findings included major malformations: bilateral hip dislocation, dislocation of the left knee, extreme micrognathia, and microsomy. Up to date, 11 liveborn infants with trisomy 9 have been reported, which allows us to make a karyotype/phenotype correlation. Minimal clinical diagnostic criteria are defined, on the basis of which the presence of this syndrome can be suspected. Images PMID:7143394
The Impact of Lumbar Spine Disease and Deformity on Total Hip Arthroplasty Outcomes.
Blizzard, Daniel J; Sheets, Charles Z; Seyler, Thorsten M; Penrose, Colin T; Klement, Mitchell R; Gallizzi, Michael A; Brown, Christopher R
2017-05-01
Concomitant spine and hip disease in patients undergoing total hip arthroplasty (THA) presents a management challenge. Degenerative lumbar spine conditions are known to decrease lumbar lordosis and limit lumbar flexion and extension, leading to altered pelvic mechanics and increased demand for hip motion. In this study, the effect of lumbar spine disease on complications after primary THA was assessed. The Medicare database was searched from 2005 to 2012 using International Classification of Diseases, Ninth Revision, procedure codes for primary THA and diagnosis codes for preoperative diagnoses of lumbosacral spondylosis, lumbar disk herniation, acquired spondylolisthesis, and degenerative disk disease. The control group consisted of all patients without a lumbar spine diagnosis who underwent THA. The risk ratios for prosthetic hip dislocation, revision THA, periprosthetic fracture, and infection were significantly higher for all 4 lumbar diseases at all time points relative to controls. The average complication risk ratios at 90 days were 1.59 for lumbosacral spondylosis, 1.62 for disk herniation, 1.65 for spondylolisthesis, and 1.53 for degenerative disk disease. The average complication risk ratios at 2 years were 1.66 for lumbosacral spondylosis, 1.73 for disk herniation, 1.65 for spondylolisthesis, and 1.59 for degenerative disk disease. Prosthetic hip dislocation was the most common complication at 2 years in all 4 spinal disease cohorts, with risk ratios ranging from 1.76 to 2.00. This study shows a significant increase in the risk of complications following THA in patients with lumbar spine disease. [Orthopedics. 2017; 40(3):e520-e525.]. Copyright 2017, SLACK Incorporated.
Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S
2012-05-01
Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.
Moussa, Mohamed E.; Esposito, Christina I.; Elpers, Marcella E.; Wright, Timothy M.; Padgett, Douglas E.
2014-01-01
The aims of this study were to assess damage on the surface of retrieved oxidized zirconium metal (OxZr) femoral heads, to measure surface roughness of scratches, and to evaluate the extent of surface effacement using scanning electron microscopy (SEM). Ceramic zirconia-toughened alumina (ZTA) heads were analyzed for comparison. OxZr femoral heads explanted for recurrent dislocation had the most severe damage (p<0.001). The median surface roughness of damaged OxZr femoral heads was 1.49μm, compared to 0.084μm for damaged ZTA heads and 0.052μm for undamaged OxZr (p<0.001). This may be of clinical concern because increased surface roughness has the potential to increase the wear of polyethylene liners articulating against these OxZr heads in THA. PMID:25443362
Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan
2015-10-01
Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.
Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C
2011-11-01
Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.
Snijders, Thom E; Willemsen, Koen; van Gaalen, Steven M; Castelein, Rene M; Weinans, Harrie; de Gast, Arthur
2018-05-01
Dislocation is one of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. Twenty eight relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.
Babiak, Ireneusz
2012-07-03
Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.
Innovations in the management of hip fractures.
Teasdall, Robert D; Webb, Lawrence X
2003-08-01
Hip fractures include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region that is exposed to large compressive stresses. Implants used to address these fractures must accommodate significant loads while the fractures consolidate. Complications secondary to hip fractures produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.
Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.
Kouzelis, A; Georgiou, C S; Megas, P
2012-12-01
Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.
Acker, A; Fischer, J-F; Aminian, K; Lécureux, E; Jolles, B M
2017-02-01
Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup? We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age. Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined. All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12.1 (range 0-34) in the THA group. We observed no dislocations. Gait patterns five years following THA with the dual-mobility cup were better or comparable to published study populations. III, retrospective case-control series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Total hip arthroplasty performed in patients with residual poliomyelitis: does it work?
Yoon, Byung-Ho; Lee, Young-Kyun; Yoo, Jeong Joon; Kim, Hee Joong; Koo, Kyung-Hoi
2014-03-01
Patients with residual poliomyelitis can have advanced degenerative arthritis of the hip in the paralytic limb or the nonparalytic contralateral limb. Although THA is a treatment option for some of these patients, there are few studies regarding THA in this patient population. We therefore reviewed a group of patients with residual poliomyelitis who underwent cementless THA on either their paralytic limb or nonparalytic limb to assess (1) Harris hip scores, (2) radiographic results, including implant loosening, (3) complications, including dislocation, and (4) limb length discrepancy after recovery from surgery. From January 2000 to December 2009, 10 patients with residual poliomyelitis (10 hips, four paralytic limbs and six nonparalytic contralateral limbs) underwent THA using cementless prostheses. Harris hip scores, complications, and leg length discrepancy were determined by chart review, and confirmed by questionnaire and examination; radiographs were reviewed by two observers for this study. Followup was available for all 10 patients at a minimum of 3 years (median, 7 years; range, 3.4-13 years). Surgery was done at the same side of the paralytic limb in four hips and contralateral to the paralytic limb in six. All patients had pain relief and improvement in function; the Harris hip score improved from mean of 68 preoperatively to 92 at last followup (p = 0.043). However, only three patients had complete pain relief. One hip dislocated, which was treated successfully with closed reduction and a hip spica cast for 2 months. There was no loosening or osteolysis in this series. Leg length discrepancy improved after the index operation, but only in the THAs performed in the paralytic limbs. Cementless THA may be suitable for painful hips in adult patients with residual poliomyelitis. Nonetheless, these patients should be informed of the possibility of mild residual pain and persistent leg length discrepancy, particularly patients whose THA is performed on the limb that was not affected by polio (ie, the nonparalytic contralateral limb). Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
Blizzard, Daniel J; Penrose, Colin T; Sheets, Charles Z; Seyler, Thorsten M; Bolognesi, Michael P; Brown, Christopher R
2017-08-01
Ankylosing spondylitis (AS) is a chronic autoimmune spondyloarthropathy that primarily affects the axial spine and hips. Progressive disease leads to pronounced spinal kyphosis, positive sagittal balance, and altered biomechanics. The purpose of this study is to determine the complication profile of patients with AS undergoing total hip arthroplasty (THA). The Medicare sample was searched from 2005 to 2012 yielding 1006 patients with AS who subsequently underwent THA. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for 90-day, 2-year, and the final postoperative follow-up for complications including hip dislocation, periprosthetic fracture, wound complication, revision THA, and postoperative infection. Compared to controls, AS patients had an RR of 2.50 (CI, 1.04-5.99) of THA component breakage at 90-days post-operatively and 1.99 (CI, 1.10-3.59) at 2-years. The RR of periprosthetic hip dislocation was elevated at 90 days (1.44; CI, 0.93-2.22) and significantly increased at 2-years (1.67; CI, 1.25-2.23) and overall follow-up (1.49; CI, 1.14-1.93). Similarly, the RR for THA revision was elevated at 90-days (1.46; CI, 0.97-2.18) and significantly increased at 2-years (1.69; CI, 1.33-2.14) and overall follow-up (1.51; CI, 1.23-1.85). Patients with AS are at increased risk for complications after THA. Altered biomechanics from a rigid, kyphotic spine place increased demand on the hip joints. The elevated perioperative and postoperative risks should be discussed preoperatively, and these patients may require increased preoperative medical optimization as well as possible changes in component selection and position to compensate for altered spinopelvic biomechanics. Copyright © 2017 Elsevier Inc. All rights reserved.
Unplanned hip arthroplasty imposes clinical and cost burdens on treating institutions.
Kamath, Atul F; Austin, Daniel C; Derman, Peter B; Israelite, Craig L
2013-12-01
Emergent surgery has been shown to be a risk factor for perioperative complications. Studies suggest that patient morbidity is greater with an unplanned hip arthroplasty, although it is controversial whether unplanned procedures also result in higher patient mortality. The financial impact of these procedures is not fully understood, as the costs of unplanned primary hip arthroplasties have not been studied previously. We asked: (1) What are the institutional costs associated with unplanned hip arthroplasties (primary THA, hemiarthroplasty, revision arthroplasty, including treatment of periprosthetic fractures, dislocations, and infections)? (2) Does timing of surgery (urgent/unplanned versus elective) influence perioperative outcomes such as mortality, length of stay, or need for advanced care? (3) What diagnoses are associated with unplanned surgery and are treated urgently most often? (4) Do demographics and insurance status differ between admission types (unplanned versus elective hip arthroplasty)? We prospectively followed all 419 patients who were admitted to our Level I trauma center in 2011 for procedures including primary THA, hemiarthroplasty, and revision arthroplasty, including the treatment of periprosthetic fractures, dislocations, and infections. Fifty-seven patients who were treated urgently on an unplanned basis were compared with 362 patients who were treated electively. Demographics, admission diagnoses, complications, and costs were recorded and analyzed statistically. Median total costs were 24% greater for patients admitted for unplanned hip arthroplasties (USD 18,206 [USD 15,261-27,491] versus USD 14,644 [USD 13,511-16,309]; p < 0.0001) for patients admitted for elective arthroplasties. Patients with unplanned admissions had a 67% longer median hospital stay (5 days [range, 4-9 days] versus 3 days [range, 3-4 days]; p < 0.0001) for patients with elective admissions. Mortality rates were equivalent between groups (p = 1.0). Femoral fracture (p < 0.0001), periprosthetic fracture (p = 0.01), prosthetic infection (p = 0.005), and prosthetic dislocation (p < 0.0001) were observed at higher rates in the patients with unplanned admissions. These patients were older (p = 0.04), less likely to have commercial insurance (p < 0.0001), more likely to be transferred from another institution (p < 0.0001), and more likely to undergo a revision procedure (p < 0.0001). Unplanned arthroplasty and urgent surgery are associated with increased financial and clinical burdens, which must be accounted for when considering bundled quality and reimbursement measures for these procedures.
Orthopaedic manifestations of campomelic dysplasia.
Khoshhal, Khalid; Letts, R Mervyn
2002-08-01
Campomelic dysplasia is a rare form of congenital dwarfism associated with potentially fatal respiratory insufficiency. There are several types of campomelic dysplasia; however, it is characterized by the presence of anteriorly bowed tibias with cutaneous dimpling, anterolaterally bowed femurs, thoracic kyphoscoliosis, hypoplastic scapulas, and absence or delayed ossification of thoracic pedicles. With improving treatment of respiratory insufficiency, the survival rate of affected infants has increased, thereby necessitating treatment of the musculoskeletal malformations to prevent additional morbidity. In an attempt to increase awareness of the presentation of infants with campomelic dysplasia and to emphasize the difficulties of treating associated developmental dislocation of the hip early, the current authors report the case of a 2-year-old girl with campomelic dysplasia who was treated for dislocation of the right hip. The postoperative course of this child was complicated seriously by several apneic episodes secondary to tracheobronchial malacia for which she required admission to the pediatric intensive care unit.
High-quality vertical light emitting diodes fabrication by mechanical lift-off technique
NASA Astrophysics Data System (ADS)
Tu, Po-Min; Hsu, Shih-Chieh; Chang, Chun-Yen
2011-10-01
We report the fabrication of mechanical lift-off high quality thin GaN with Hexagonal Inversed Pyramid (HIP) structures for vertical light emitting diodes (V-LEDs). The HIP structures were formed at the GaN/sapphire substrate interface under high temperature during KOH wet etching process. The average threading dislocation density (TDD) was estimated by transmission electron microscopy (TEM) and found the reduction from 2×109 to 1×108 cm-2. Raman spectroscopy analysis revealed that the compressive stress of GaN epilayer was effectively relieved in the thin-GaN LED with HIP structures. Finally, the mechanical lift-off process is claimed to be successful by using the HIP structures as a sacrificial layer during wafer bonding process.
Design of a hip prosthetic tribometer based on salat gait cycle
NASA Astrophysics Data System (ADS)
Towijaya, T.; Ismail, R.; Jamari, J.
2017-01-01
Indonesia is the country with the largest muslim population in the world, most of the inhabitants do salat every day. THR (Total Hip Replacement) patients are prohibited from doing salat in normal gait. It leads to the damage of the hip joint prostheses due to impingement and dislocation.This paper reports the design of a pin-on-ring tribometer which is used to measure and analyze the wear volume and the impingement of hip joint prostheses during salat. The modifications of the femoral head and acetabular cup holder are performed to design the reciprocating motion for the movement of the hip prostheses. The interesting finding of the present research is a new mechanism of linked-bar which leads to the feasibility of the measurement of the wear volume and the impingement for THR patients during salat.
Tong, Kuang; Zhang, Yuanzhi; Zhang, Sheng; Yu, Bin
2013-06-01
To provide an accurate method for osteotomy in the treatment of developmental dysplasia of the hip with steel osteotomy by three-dimensional reconstruction and Reverse Engineering technique. Between January 2011 and December 2012, 13 children with developmental dysplasia of the hip underwent steel osteotomy. 3D CT scan pelvic images were obtained and transferred via a DICOM network into a computer workstation to construct 3D models of the hip using Materialise Mimics 14.1 software in STL format. These models were imported into Imageware 12.0 software for steel osteotomy simulation until a stable hip was attained in the anatomical position for dislocation or subluxation of the hip in older children. The osteotomy navigational templates were designed according to the anatomical features after a stable hip was reconstructed. These navigational templates were manufactured using a rapid prototyping technique. The reconstruction hips in these children show good matching property and acetabulum cover. The computer-aided design of osteotomy template provides personalized and accurate solutions in the treatment of developmental dysplasia of the hip with steel osteotomy in older children.
Instability of total hip replacement: A clinical study and determination of its risk factors.
Ezquerra-Herrando, L; Seral-García, B; Quilez, M P; Pérez, M A; Albareda-Albareda, J
2015-01-01
To determine the risk factors associated with prosthetic dislocation and simulate a finite element model to determine the safe range of movement of various inclination and anteversion cup positions. Retrospective Case Control study with 46 dislocated patients from 1994 to 2011. 83 randomly selected patients. Dislocation risk factors described in the literature were collected. A prosthetic model was simulated using finite elements with 28, 32, 36 mm heads, and a 52 mm cup. Acetabular position was 25°, 40°, and 60° tilt and with 0°, 15° and 25° anteversion. In extension of 0° and flexion of 90°, internal and external rotation was applied to analyze the range of movement, maximum resisting moment, and stress distribution in the acetabulum to impingement and dislocation. There was greater dislocation in older patients (p=0.002). Higher dislocation in fractures than in osteoarthritis (p=0.001). Less anteversion in dislocated patients (p=0.043). Longer femoral neck in dislocated patients (p=0.002). Finite element model: lower dislocation when there is more anteversion, tilt and bigger femoral heads. Advanced age and fractures are the major risk factors for dislocation. "Safe zone" of movement for dislocation avoidance is 40°-60° tilt and 15°-25° anteversion. Both the defect and excess of soft tissue tension predispose to dislocation. Bigger femoral heads are more stable. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie
2009-02-15
To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.
Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation.
Hamadouche, Moussa; Ropars, Mickael; Rodaix, Camille; Musset, Thierry; Gaucher, François; Biau, David; Courpied, Jean Pierre; Huten, Denis
2017-03-01
Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. The series included 51 patients with a mean age of 71.3 ± 11.5 (range, 41-98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8 ± 2.3 years, three were lost to follow-up at a mean of 1.4 years, seven had been revised at a mean of 4.7 ± 3.1 years (range, 1.5-9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2 ± 2.4 years (range, 5-13 years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9 ± 2.9 years (range, 2.7-9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten years, using re-dislocation as the end-point, was 86.1 ± 8.4% (95% confidence interval, 69.7-100%). The survival rate of the cup at ten years, using revision for any reason as the end-point, was 75.2 ± 9.3% (95% confidence interval, 56.9-93.5%). A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten years was related to this specific patients population that had various co-morbidities.
Socket position determines hip resurfacing 10-year survivorship.
Amstutz, Harlan C; Le Duff, Michel J; Johnson, Alicia J
2012-11-01
Modern metal-on-metal hip resurfacing arthroplasty designs have been used for over a decade. Risk factors for short-term failure include small component size, large femoral head defects, low body mass index, older age, high level of sporting activity, and component design, and it is established there is a surgeon learning curve. Owing to failures with early surgical techniques, we developed a second-generation technique to address those failures. However, it is unclear whether the techniques affected the long-term risk factors. We (1) determined survivorship for hips implanted with the second-generation cementing technique; (2) identified the risk factors for failure in these patients; and (3) determined the effect of the dominant risk factors on the observed modes of failure. We retrospectively reviewed the first 200 hips (178 patients) implanted using our second-generation surgical technique, which consisted of improvements in cleaning and drying the femoral head before and during cement application. There were 129 men and 49 women. Component orientation and contact patch to rim distance were measured. We recorded the following modes of failure: femoral neck fracture, femoral component loosening, acetabular component loosening, wear, dislocation, and sepsis. The minimum followup was 25 months (mean, 106.5 months; range, 25-138 months). Twelve hips were revised. Kaplan-Meier survivorship was 98.0% at 5 years and 94.3% at 10 years. The only variable associated with revision was acetabular component position. Contact patch to rim distance was lower in hips that dislocated, were revised for wear, or were revised for acetabular loosening. The dominant modes of failure were related to component wear or acetabular component loosening. Acetabular component orientation, a factor within the surgeon's control, determines the long-term success of our current hip resurfacing techniques. Current techniques have changed the modes of failure from aseptic femoral failure to wear or loosening of the acetabular component. Level III, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
Li, Xigong; Sun, Junying; Lin, Xiangjin; Xu, Sanzhong; Tang, Tiansi
2013-06-01
The authors describe a modified double chevron subtrochanteric shortening osteotomy combined with cementless total hip arthroplasty for Crowe type-IV hip dysplasia. Shortening the femur allows to relax the shortened musculature. This operation was performed in 18 patients (22 hips) between January 2000 and February 2006. The mean follow-up period was 5.6 years (range: 3 to 8 years). The mean amount of femoral subtrochanteric shortening was 38 mm (range: 25 to 60 mm). The mean Harris hip score improved from 47 (range: 35 to 65) preoperatively to 88 points (range: 75 to 97) at final follow-up. The Trendelenburg sign was corrected from positive to negative in 12 of 22 hips. No acetabular or femoral components loosened or required revision during the follow-up period. All osteotomy sites healed in 3 to 6 months without complications. Cementless total hip arthroplasty using the modified double chevron subtrochanteric osteotomy provided good short- to midterm results in all 22 Crowe type-IV hip dislocations. Moreover, it restored the anatomic hip center and the limb length, which contributed to correction of the preoperative limp.
Schmitt, Jürgen W; Benden, Christian; Dora, Claudio; Werner, Clément M L
2016-01-01
In recent years, the number of lung transplants has increased rapidly, with higher quality of life and improved survival rates in transplant recipients, including patients with advanced age. This, in turn, means that more transplant recipients will seek musculoskeletal care to treat degenerative joint disease and also trauma incidents. Safety concerns regarding elective and posttraumatic hip arthroplasty in transplant patients include an increased risk of infection, wound healing problems, periprosthetic fractures and loosening of the implants. Clinical outcomes and safety aspects were retrospectively reviewed for five primary total hip arthroplasties (THA) in lung transplant recipients with minimal follow-up of two years at average of 2.6 (2-11) years. Patients were recruited from the Zurich Lung Transplant Center comprising of a cohort of 253 patients between January 1st, 2004 and December 31st, 2013. All five patients subjectively reported excellent outcomes after THA with a final average Harris Hip Score of 97 (86-100). One 71-year-old patient died 26 months after THA unrelated to arthroplasty. One superficial wound healing disturbance was documented. No periprosthetic fractures, no dislocations, no periprosthetic infections, no further revision surgery, no implant loosening was observed. In conclusion, THA can be safely and successfully performed even in lung transplant patients under long-term immunosuppressive therapy and polymedication, provided a multidisciplinary approach can be granted.
Complications in Hip Arthroscopy
Nakano, Naoki; Khanduja, Vikas
2016-01-01
Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747
Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.
Lombardi, Adolph V; Berend, Keith R; Morris, Michael J; Adams, Joanne B; Sneller, Michael A
2015-02-01
Use of large-diameter metal-on-metal (MoM) articulations in THA increased, at least in part, because of the possibility of achieving improved joint stability and excellent wear characteristics in vitro. However, there have been subsequent concerning reports with adverse reactions to metal debris (ARMD), pseudotumors, and systemic complications related to metal ions. The purpose of this study was to determine at a minimum of 2 years' followup (1) the proportion of patients who experienced a dislocation; (2) the short-term survivorship obtained with these implants; (3) the causes of failure and the proportion of patients who developed ARMD; and (4) whether there were any identifiable risk factors for revision. We reviewed the results of 1235 patients who underwent 1440 large-diameter MoM primary THAs at our institution using two acetabular devices from a single manufacturer with minimum 2-year followup. Large-diameter MoM devices were used in 48% (1695 of 3567) of primary THAs during the study period. We generally used these implants in younger, more active, higher-demand patients, in patients considered at higher risk of instability, and in patients with adequate bone stock to achieve stable fixation without use of screws. Clinical records and radiographs were reviewed to determine the incidence and etiology of revision. Patients whose hips were revised were compared with those not revised to identify risk factors; Kaplan-Meier survivorship analysis was performed as was multivariate analysis to account for potential confounding variables when evaluating risk factors. Minimum followup was 2 years (average, 7 years; range, 2-12 years); complete followup was available in 85% of hips (1440 of 1695). Dislocation occurred in one hip overall (<1%; one of 1440). Kaplan-Meier analysis revealed survival free of component revision was 87% at 12 years (95% confidence interval, 84%-90%). The two most common indications for revision were ARMD (48%; 47 of 108 hips revised) and loosening or failure of ingrowth (31%; 34 of 108). Risk factors for component revision were younger age at surgery (relative risk [RR] 0.98 per each increased year; p=0.02), higher cup angle of inclination (RR 1.03 per each increased degree; p=0.04), and female sex (RR 1.67; p=0.03). Large-diameter MoM THAs are associated with a very low dislocation rate, but failure secondary to ARMD and loosening or lack of ingrowth occur frequently. Patients with MoM THA should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Early diagnosis and appropriate treatment are recommended to prevent the damaging effects of advanced ARMD. Level IV, Therapeutic study.
Fabricant, Peter D; Dy, Christopher J; Patel, Ronak M; Blanco, John S; Doyle, Shevaun M
2013-06-01
The recent emphasis on shared decision-making has increased the role of the Internet as a readily accessible medical reference source for patients and families. However, the lack of professional review creates concern over the quality, accuracy, and readability of medical information available to patients on the Internet. Three Internet search engines (Google, Yahoo, and Bing) were evaluated prospectively using 3 difference search terms of varying sophistication ("congenital hip dislocation," "developmental dysplasia of the hip," and "hip dysplasia in children"). Sixty-three unique Web sites were evaluated by each of 3 surgeons (2 fellowship-trained pediatric orthopaedic attendings and 1 orthopaedic chief resident) for quality and accuracy using a set of scoring criteria based on the AAOS/POSNA patient education Web site. The readability (literacy grade level) of each Web site was assessed using the Fleisch-Kincaid score. There were significant differences noted in quality, accuracy, and readability of information depending on the search term used. The search term "developmental dysplasia of the hip" provided higher quality and accuracy compared with the search term "congenital hip dislocation." Of the 63 total Web sites, 1 (1.6%) was below the sixth grade reading level recommended by the NIH for health education materials and 8 (12.7%) Web sites were below the average American reading level (eighth grade). The quality and accuracy of information available on the Internet regarding developmental hip dysplasia significantly varied with the search term used. Patients seeking information about DDH on the Internet may not understand the materials found because nearly all of the Web sites are written at a level above that recommended for publically distributed health information. Physicians should advise their patients to search for information using the term "developmental dysplasia of the hip" or, better yet, should refer patients to Web sites that they have personally reviewed for content and clarity. Orthopaedic surgeons, professional societies, and search engines should undertake efforts to ensure that patients have access to information about DDH that is both accurate and easily understandable.
HEMIARTHROPLASTY IN THE TREATMENT FRACTURES OF THE FEMORAL NECK
Ono, Nelson Keiske; de Andrade Lima, Guilherme Didier; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Guimarães, Rodrigo Pereira; Júnior, Walter Ricioli; de Queiroz, Marcelo Cavalheiro
2015-01-01
Objective: To epidemiologically and clinically evaluate patients with displaced femoral neck fractures that were surgically treatment with cemented hip hemiarthroplasty. Methods: All patients with displaced femoral neck fractures (Garden III and IV) who underwent cemented hip hemiarthroplasty using a unipolar prosthesis (Thompson), by means of a posterolateral access between June 2005 and September 2008 were retrospectively evaluated. Results: Seventy patients were initially evaluated. Their mean age was 83.1 years. The patients were predominantly female (84.3%). Thirty-six patients were monitored as outpatients for periods ranging from 10 to 48 months (mean of 26.5 months). Fifteen patients were lost to follow-up. Nineteen patients died, and the mortality rate within the first year was 25.4%. Patients classified as ASA III had a mortality rate of 25.7% and ASA II patients, a rate of 12.1%. Two patients had symptomatic deep vein thrombosis; one patient had an operative wound infection; and none of the patients presented hip dislocation. Most of the patients did not experience pain. Twelve patients (33%) showed deterioration of their walking ability. Conclusion: There were no cases of hip dislocation. Patients classified as ASA III had a higher mortality rate than did patients with ASA I or II. There was a worsening of walking ability in 33% of the patients. No revision due to loosening or pain was needed for any patient. Thirty patients did not present any pain (83.3%), four presented moderate pain (11.1%) and two presented intense pain (5.5%). PMID:27022567
Jung, N H; Heinen, F; Westhoff, B; Doederlein, L; Reissig, A; Berweck, S; Linder-Lucht, M; Schandelmaier, S; Mall, V
2011-02-01
We investigated the effect of BoNT/A injection on hip lateralisation in children with bilateral spastic cerebral palsy and bilateral adductor spasticity. Pelvic radiographs using Reimers' migration index (MI) were evaluated from 27 children (n=9 females, n=18 males; mean age 5.2 ± 1.96 years; range: 2-10 years; initial MI <50%) with bilateral spastic cerebral palsy over a time period of 2 years. All received injections of BoNT/A (Dysport) every 12 weeks with a dose of 30 Units per kilogram body weight into adductor and medial hamstring muscles on both sides. The MI was calculated before treatment and after 1 and 2 years. The mean MI increased from 25.5% (range: 0-48) to 26.7% (+1.2%, range: 0-79) on the right side and from 28.0% (range: 0-40) to 30.6% (+2.6%, range: 3-84) on the left side over 2 years, respectively. Hips of one patient dislocated bilaterally. The mean MI remained stable over 2 years. Although a specific BoNT/A effect cannot be proven because of the open design of this study, we provide strong evidence that the MI can be kept stable for a time period of 2 years under non-surgical management including therapy with BoNT/A even in CP patients with a high risk for hip dislocation. © Georg Thieme Verlag KG Stuttgart · New York.
Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun
2017-02-01
Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.
Prymka, M; Hassenpflug, J
2003-08-01
This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.
An unusual mode of failure of a tripolar constrained acetabular liner: a case report.
Banks, Louisa N; McElwain, John P
2010-04-01
Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.
The three-pin modified 'Harrington' procedure for advanced metastatic destruction of the acetabulum.
Tillman, R M; Myers, G J C; Abudu, A T; Carter, S R; Grimer, R J
2008-01-01
Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.
Pandit, R
1996-08-01
Primary bipolar femoral head arthroplasties performed on 100 osteoarthritic hips were studied to a minimum of 5 years after surgery. All arthroplasties were performed on physically active patients. At a mean follow-up period of 5.5 years, The Hospital for Special Surgery hip scores were good to excellent in 96 hips. Transient startup soreness constituted the most frequent complaint, occurring in 34 hips. Three hips had more persistent pain localized to the acetabulum, necessitating revision to fixed sockets, which alleviated the symptoms. Four additional hips, in heavy, active men, developed polyethylene fatigue fracture and component disassembly. Acetabular migration of more than 5 mm developed in one hip. Motion, as determined radiologically, occurred primarily at the inner bearing. There were no dislocations or infections in the series. The Bateman bipolar prosthesis provides generally good results in osteoarthritic hips. The shorter operating time and the case of revision are special advantages of bipolar devices. Start-up soreness and stiffness is a shortcoming in approximately one third of cases. Component disassembly in heavy, active men is a problem and the bipolar arthroplasty should be avoided in these patients. Start-up soreness was a significant problem in particular.
Cho, Yoon J; Lee, Choong H; Chun, Young S; Rhyu, Kee H
2016-09-29
In this case series, we investigated the outcome of cementless total hip arthroplasty (THA) for advanced hip osteoarthritis in patients with residual poliomyelitis to evaluate its clinical usefulness for these patients. 11 unilateral cementless primary THA were performed to arthritic hips in patients with residual poliomyelitis. 7 were in paralytic and 4 were in nonparalytic limbs. The mean follow-up duration was 79.9 months. Retrospective clinical evaluations with various scores and radiological evaluations were made. Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Short-form (SF)-36 physical scales were significantly improved after the surgery. However, UCLA activity score and SF-36 mental scale were not. Because of remaining leg length discrepancies, all but 1 noted a residual limp. In nonparalytic hip, functional acetabular cup inclination during weight bearing significantly increased from installed inclination. Other than 1 case of posterior dislocation, no complications were observed. Although the overall result itself is excellent, THA for these patients cannot improve limp, physical activity and mental status. Surgeons should be aware of the change of the inclination of acetabular cup during mobilisation, especially for THA in contralateral hip.
Hip health at skeletal maturity: a population-based study of young adults with cerebral palsy.
Wawrzuta, Joanna; Willoughby, Kate L; Molesworth, Charlotte; Ang, Soon Ghee; Shore, Benjamin J; Thomason, Pam; Graham, H Kerr
2016-12-01
We studied 'hip health' in a population-based cohort of adolescents and young adults with cerebral palsy to investigate associations between hip morphology, pain, and gross motor function. Ninety-eight young adults (65 males, 33 females) from the birth cohort were identified as having developed hip displacement (migration percentage >30) and were reviewed at a mean age of 18 years 10 months (range 15-24y). Hip morphology was classified using the Melbourne Cerebral Palsy Hip Classification Scale (MCPHCS). Severity and frequency of pain were recorded using Likert scales. Gross motor function was classified by the Gross Motor Function Classification System (GMFCS). Hip pain was reported in 72% of participants. Associations were found between pain scores and both hip morphology and GMFCS. Median pain severity score for MCPHCS grades 1 to 4 was 2 (interquartile range [IQR] 1.0-3.0) compared to 7 (IQR 6.0-8.0) for grades 5 and 6 (severe subluxation or dislocation). Hip surveillance and access to surgery were associated with improved hip morphology and less pain. Poor hip morphology at skeletal maturity was associated with high levels of pain. Limited hip surveillance and access to surgery, rather than GMFCS, was associated with poor hip morphology. The majority of young adults who had access to hip surveillance, and preventive and reconstructive surgery, had satisfactory hip morphology at skeletal maturity and less pain. © 2016 Mac Keith Press.
Xu, Ning; Sun, Junying; Zhao, Xijiang; Wang, Tao
2016-01-01
To investigate the application and effectiveness of the biological type acetabular cup(diameter < 44 mm) in adult Crowe type IV developmental dysplasia of the hip (DDH). Between April 2001 andAugust 2013, biological type acetabular cup was used in total hip arthroplasty for the treatment of Crowe type IV DDH in16 cases (20 hips). There were 3 males and 13 females, aged 31-69 years (mean, 49 years). Unilateral hip was involved in 12cases, and bilateral hips in 4 cases. The patients showed pain of the hip joint and inequality of lower limb (shortening ofaffected limb 1.8-6.0 cm in length, 3.5 cm on average). Acetabular deformity, the relationship and the severity of femoralhead dislocation were comfirmed on the X-ray films. The preoperative Harris score was 34.0 ± 6.9. All patientsachieved healing of incision by first intention, with no complication of infection or neurovascular injury. Sixteen caseswere followed up 4-12 years (mean, 7.5 years). At 2 weeks after operation, dislocation occurred in 2 cases, and were fixedwith plaster for 3 weeks after reduction of the hip. Postoperative X-ray films showed complete reduction of femoral head;the average acetabular coverage of the cup of the weight-bearing area was 98.5% (range, 98.2%-99.1%). The cup from theRanawat triangle was 4.6-7.0 mm (mean, 5.8 mm) in medial shifting, and was 4.5-7.9 mm (mean, 6.2 mm) in elevation,it located at cup lateral surface area inside the iliopectineal line and the Kohler line (< 40%); the cup abduction angle was(45 ± 5)degrees, and the anteversion angle was (10 ± 5)degrees. The other patients had no prosthesis loosening except 1 patient havingextensive acetabular prosthesis loosening because of acetabular osteolysis at 12 years after operation. The hip Harris scorewas significantly improved to 85.0 ± 7.5 at 1 year after operation (t = 14.34, P = 0.01). The acetabular grindingprocess to retain enough bone combined with a small cup of-biological prosthesis treating adult Crowe type IV DDH has theadvantages of satisfactory coverage and initial acetabular fixation, so good early and mid-term effectiveness can be obtained.
Medial versus anterior open reduction for developmental hip dislocation in age-matched patients.
Hoellwarth, Jason S; Kim, Young-Jo; Millis, Michael B; Kasser, James R; Zurakowski, David; Matheney, Travis H
2015-01-01
The difference between medial (MAOR) and anterior (AAOR) approaches for open reduction of developmental hip dysplasia in terms of risk for avascular necrosis (AVN) and need for further corrective surgery (FCS, femoral and/or acetabular osteotomy) is unclear. This study compared age-matched cohorts undergoing either MAOR or AAOR in terms of these 2 primary outcomes. Prognostic impact of presence of ossific nucleus at time of open reduction was also investigated. Institutional review board approval was obtained. Nineteen hips (14 patients) managed by MAOR were matched with 19 hips (18 patients) managed by AAOR based on age at operation (mean 6.0; range, 1.4 to 14.9 mo). Patients with neuromuscular conditions and known connective tissue disorders were excluded. Primary outcomes assessed at minimum 2 years' follow-up included radiographic evidence of AVN (Kalamchi and MacEwen) or requiring FCS. MAOR and AAOR cohorts were similar regarding age at open reduction, sex, laterality, and follow-up duration. One hip in each group had AVN before open reduction thus were excluded from AVN analysis. At minimum 2 years postoperatively (mean 6.2; range, 1.8 to 11.7 y), 4/18 (22%) MAOR and 5/18 (28%) AAOR met the same criteria for AVN (P=1.0). No predictors of AVN could be identified by regression analysis. Presence of an ossific nucleus preoperatively was not a protective factor from AVN (P=0.27). FCS was required in 4/19 (21%) MAOR and 7/19 (37%) AAOR hips (P=0.48). However, 7/12 (54%) hips failing closed reduction required FCS compared with 4/26 (16%) hips without prior failed closed reduction (P=0.024). Cox regression analysis showed that patients who failed closed reduction had an annual risk of requiring FCS approximately 6 times that of patients without a history of failed closed reduction (hazard ratio=6.1; 95% CI, 1.5-24.4; P=0.009), independent of surgical approach (P=0.55) or length of follow-up (P=0.78). In this study of age-matched patients undergoing either MAOR or AAOR, we found no association between surgical approach and risk of AVN or FCS. In addition, we identified no protective benefit of a preoperative ossific nucleus in terms of development of AVN. However, failing closed reduction was associated with a 6-fold increased annual risk of requiring FCS. To the best of our knowledge, this is the first study comparing these 2 surgical techniques in an age-matched manner. It further corroborates previous studies stating that there may be no difference in risk of AVN based on surgical approach or presence of ossific nucleus preoperatively. Level III-retrospective comparative study.
Viste, A; Chouteau, J; Testa, R; Chèze, L; Fessy, M-H; Moyen, B
2011-05-01
Accurate positioning of the acetabular cup in primary total hip arthroplasty is critical to decrease the rate of dislocation. Inaccurate orientation of the cup is the most common error during this procedure. Target acetabular orientation is still controversial. An original study found a dislocation rate of 0.6% when the cup was aligned with the transverse acetabular ligament (TAL). TAL is a patient-specific anatomical landmark and a tool for cup orientation. Eight cadaveric pelves (14 hips included for study) were harvested in toto at our research laboratory. Anatomical versions of the TAL, labrum and horns were measured in relation to the anterior pelvic plane. A navigator sensor and an optoelectronic device (Motion Analysis™) were used. Anatomical versions of the TAL, horns and labrum averaged 1.9° (range, -8° to +13.3°), 3° (range, -12.2° to 14°), and 26.3° (range, 17.4° to 41.8°), respectively. To our knowledge, this is the first study to report the orientation of the periacetabular soft-tissues. TAL anteversion was outside the safe zone described by Lewinnek, while labrum anteversion was within this safe-zone. We discuss the reference used, Lewinnek's safe zone, and functional orientation of the implants. Lewinnek's safe-zone does not seem to be valid. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Modern dual-mobility cup implanted with an uncemented stem: about 100 cases with 12-year follow-up.
Philippot, Remi; Meucci, Jean Francois; Boyer, Bertrand; Farizon, Frederic
2013-09-01
We report the results of a 12-year follow-up retrospective series of 100 total hip arthroplasties using cementless, press-fit, dual-mobility acetabular cups. The aim of our study was to evaluate the clinical and radiographic results of this acetabular cup at last follow-up. This continuous and homogeneous series included 100 primary total hip arthroplasties performed during the year 2000. The THA combined a Corail® stem (Corail®, Depuy, Warsaw, IN) with a stainless steel Novae Sunfit® (Serf, Decines, France) acetabular cup. Fifteen patients died and 2 were lost to follow-up. Two cases of early dislocation were observed, and 3 cases of aseptic loosening of the acetabular component were reported. The mean stem subsidence was 0.71 mm, the mean craniopodal acetabular migration was 1.37 mm, and the mean medio-lateral acetabular migration was 1.52 mm. The 12-year survivorship is comparable to the data from the literature. The low dislocation rate at 12 years confirms the long-term, high stability of dual mobility, which should be recommended in primary THA for patients at risk for postoperative instability. The absence of true intraprosthetic dislocation events at 12-year follow-up provides evidence of the good quality of the latest generation of polyethylene liners and the necessity of combining thin-mirror, polished femoral necks with dual-mobility cups.
Acetabular-epiphyseal angle and hip dislocation in cerebral palsy: a preliminary study.
Alí-Morell, O J; Zurita-Ortega, F; Davó-Jiménez, I; Segura-Biedma, S
To relate, in non-ambulatory subjects with palsy, Reimers' migration percentage with standardized radiological measurements, including the acetabular-epiphyseal angle. Descriptive, observational and transversal study of 15 individuals with cerebral palsy at levels IV and V of the Gross Motor Function Classification System, aged between 3 and 9 years. Radiological measurements of the acetabular index, Hilgenreiner's epiphyseal angle, acetabular-epiphyseal angle, neck-shaft angle and Reimers' migration percentage of each of the hips were performed. Correlations between acetabular index, epiphyseal angle and acetabular-epiphyseal angle were obtained with respect to the Reimers migration percentage. For hips with a migration rate of 15% or less, a positive correlation was observed between acetabular and epiphyseal angles. In our population, the measurement between acetabular and epiphyseal inclination represents the highest association with the hip migration percentage. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Sochacki, Kyle R; Jack, Robert A; Safran, Marc R; Nho, Shane J; Harris, Joshua D
2018-06-01
The purpose of this study was to compare (1) major complication, (2) revision, and (3) conversion to arthroplasty rates following hip arthroscopy between database studies and original research peer-reviewed publications. A systematic review was performed using PRISMA guidelines. PubMed, SCOPUS, SportDiscus, and Cochrane Central Register of Controlled Trials were searched for studies that investigated major complication (dislocation, femoral neck fracture, avascular necrosis, fluid extravasation, septic arthritis, death), revision, and hip arthroplasty conversion rates following hip arthroscopy. Major complication, revision, and conversion to hip arthroplasty rates were compared between original research (single- or multicenter therapeutic studies) and database (insurance database using ICD-9/10 and/or current procedural terminology coding terminology) publishing studies. Two hundred seven studies (201 original research publications [15,780 subjects; 54% female] and 6 database studies [20,825 subjects; 60% female]) were analyzed (mean age, 38.2 ± 11.6 years old; mean follow-up, 2.7 ± 2.9 years). The database studies had a significantly higher age (40.6 + 2.8 vs 35.4 ± 11.6), body mass index (27.4 ± 5.6 vs 24.9 ± 3.1), percentage of females (60.1% vs 53.8%), and longer follow-up (3.1 ± 1.6 vs 2.7 ± 3.0) compared with original research (P < .0001 for all). Ninety-seven (0.6%) major complications occurred in the individual studies, and 95 (0.8%) major complications occurred in the database studies (P = .029; relative risk [RR], 1.3). There was a significantly higher rate of femoral neck fracture (0.24% vs 0.03%; P < .0001; RR, 8.0), and hip dislocation (0.17% vs 0.06%; P = .023; RR, 2.2) in the database studies. Reoperations occurred at a significantly higher rate in the database studies (11.1% vs 7.3%; P < .001; RR, 1.5). There was a significantly higher rate of conversion to arthroplasty in the database studies (8.0% vs 3.7%; P < .001; RR, 2.2). Database studies report significantly increased major complication, revision, and conversion to hip arthroplasty rates compared with original research investigations of hip arthroscopy outcomes. Level IV, systematic review of Level I-IV studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Experiment K-314: Fetal and neonatal rat bone and joint development following in Utero spaceflight
NASA Technical Reports Server (NTRS)
Sabelman, E. E.; Holton, E. M.; Arnaud, C. D.
1981-01-01
Infant rat limb specimens from Soviet and U.S. ground-based studies were examined by radiography, macrophotography, histologic sectioning and staining and scanning electron microscopy. A comparison was conducted between vivarium and flight-type diets suggesting that nutritional obesity may adversely affect pregnancy. Data were obtained on maturation of ossification centers, orientation of collagen fibers in bone, tendon and ligaments, joint surface texture and spatial relationships of bones of the hind limb. Computer reconstructions of the knee and hip show promise as a means of investigating the etiology of congenital hip dislocation.
Gardner, R O E; Bradley, C S; Howard, A; Narayanan, U G; Wedge, J H; Kelley, S P
2014-02-01
The incidence of clinically significant avascular necrosis (AVN) following medial open reduction of the dislocated hip in children with developmental dysplasia of the hip (DDH) remains unknown. We performed a systematic review of the literature to identify all clinical studies reporting the results of medial open reduction surgery. A total of 14 papers reporting 734 hips met the inclusion criteria. The mean follow-up was 10.9 years (2 to 28). The rate of clinically significant AVN (types 2 to 4) was 20% (149/734). From these papers 221 hips in 174 children had sufficient information to permit more detailed analysis. The rate of AVN increased with the length of follow-up to 24% at skeletal maturity, with type 2 AVN predominating in hips after five years' follow-up. The presence of AVN resulted in a higher incidence of an unsatisfactory outcome at skeletal maturity (55% vs 20% in hips with no AVN; p < 0.001). A higher rate of AVN was identified when surgery was performed in children aged < 12 months, and when hips were immobilised in ≥ 60° of abduction post-operatively. Multivariate analysis showed that younger age at operation, need for further surgery and post-operative hip abduction of ≥ 60° increased the risk of the development of clinically significant AVN.
Haughom, Bryan D; Erickson, Brandon J; Hellman, Michael D; Jacobs, Joshua J
2015-08-01
Although metal-on-metal (MoM) bearing surfaces provide low rates of volumetric wear and increased stability, evidence suggests that certain MoM hip arthroplasties have high rates of complication and failure. Some evidence indicates that women have higher rates of failure compared with men; however, the orthopaedic literature as a whole has poorly reported such complications stratified by gender. This systematic review aimed to: (1) compare the rate of adverse local tissue reaction (ALTR); (2) dislocation; (3) aseptic loosening; and (4) revision between men and women undergoing primary MoM hip resurfacing arthroplasty (HRA). Systematic MEDLINE and EMBASE searches identified all level I to III articles published in peer-reviewed journals, reporting on the outcomes of interest, for MoM HRA. Articles were limited to those with 2-year followup that reported outcomes by gender. Ten articles met inclusion criteria. Study quality was evaluated using the Modified Coleman Methodology Score; the overall quality was poor. Heterogeneity and bias were analyzed using a Mantel-Haenszel statistical method. Women demonstrated an increased odds of developing ALTR (odds ratio [OR], 5.70 [2.71-11.98]; p<0.001), dislocation (OR, 3.04 [1.2-7.5], p=0.02), aseptic loosening (OR, 3.18 [2.21-4.58], p<0.001), and revision (OR, 2.50 [2.25-2.78], p<0.001) after primary MoM HRA. A systematic review of the currently available literature reveals a higher rate of complications (ALTR, dislocation, aseptic loosening, and revision) after MoM HRA in women compared with men. Although femoral head size has been frequently implicated as a prime factor in the higher rate of complication in women, further research is necessary to specifically probe this relationship. Retrospective studies of data available (eg, registry data) should be undertaken, and moving forward studies should report outcomes by gender (particularly complications). Level III, therapeutic study.
Won, Yougun; Lee, Gi Soo; Kim, Sang Bum; Kim, Sun Joong; Yang, Kyu Hyun
2016-11-01
As anatomical reduction of the articular surface of femoral head fractures and restoration of damaged cartilage are essential for good long-term results, many treatment options have been suggested, including fixation of the fracture using various surgical exposures and implants, as well as arthroscopic irrigation and debridement, bone marrow stimulating techniques, osteochondral allograft, autograft, and autogenous chondrocyte implantation. We report a case of osteochondral autograft harvested from its own femoral articular surface through surgical hip dislocation. The osteochondral graft was harvested from the inferior non-weight-bearing articular surface and grafted to the osteochondral defect. One year later, the clinical and radiological results were good, without the collapse of the femoral head or arthritic change. This procedure introduced in our case is considered convenient and able to lessen surgical time without morbidity of the donor site associated with the harvest.
Porter, David; Michael, Shona; Kirkwood, Craig
2008-09-01
It has been suggested that asymmetrical positioning of an infant with reduced mobility may lead to postural deformity becoming established over time. However, evidence to support or question this line of thinking is lacking. Therefore, the aim of this retrospective cohort study was to test the association between asymmetrical positioning in the first 12 months of life and the subsequent direction of postural deformity in non-ambulant people with cerebral palsy. The direction of scoliosis, pelvic obliquity and windswept hip pattern and also the side of unilateral hip subluxation/dislocation were determined for 246 young people ranging in age from 1 year and 2 months to 19 years (median age 10 years and 3 months). Parents/carers of the participants were interviewed to establish holding and feeding positions and preferred lying posture adopted in early life. Univariate analyses and multivariate logistic regression analyses were carried out. The study provided evidence of an association between asymmetrical lying posture adopted in the first year of life and the direction of the subsequent pattern of postural deformity. If the child's head had been rotated to the right during supine lying, it was more likely that the scoliosis would be convex to the left, pelvic obliquity would be lower on the left, windswept hip pattern would be to the right and hip subluxation/dislocation would occur on the left. The likelihood of the deformities occurring in the same direction was also increased if consistent side lying on the right had been preferred. Clinicians should be aware of positioning for children with severe disabilities particularly those who prefer supine lying with their head rotated to the side and those who prefer consistent side lying.
Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.
Penrose, Colin T; Seyler, Thorsten M; Wellman, Samuel S; Bolognesi, Michael P; Lachiewicz, Paul F
2016-10-01
Isolated revision of the acetabular component in the setting of total hip arthroplasty has an increased risk of dislocation. With local soft tissue destruction frequently associated with failed metal-on-metal (MoM) bearings, it is presumed that acetabular revision of these hips will have even greater risk of complications. However, no study directly compares the complications of MoM with metal-on-polyethylene (MoP) acetabular revisions. In the context of a large database analysis, we asked the following questions: (1) Are there differences in early medical or wound complications after isolated acetabular revision of MoM and MoP bearing surfaces? (2) Are there differences in the frequency of dislocation, deep infection, and rerevision based on the bearing surface of the original implant? A review of the 100% Medicare database from 2005 to 2012 was performed using International Classification of Diseases, 9th Revision and Current Procedural Terminology codes. We identified 451 patients with a MoM bearing and 628 patients with a MoP bearing who had an isolated acetabular revision and a minimum followup of 2 years. The incidence, odds ratios, and 95% confidence intervals for early medical or wound complications were calculated using a univariate analysis at 30 days with patient sex and age group-adjusted analysis for blood transfusion. The incidence, odds ratio, and 95% confidence intervals for dislocation, deep infection, and rerevision were calculated using a univariate analysis at 30 day, 90 days, 1 year, and 2 years using a subgroup analysis with the Cochran-Mantel-Haenszel test to adjust for patient gender and age groups. There were no differences between the MoM and MoP isolated acetabular revisions in the incidence of 30-day local complications. There was a greater risk of transfusion in the MoP group than the MoM group (134 of 451 [30%] versus 230 of 628 [37%]; odds ratio [OR], 0.731; 95% confidence interval [CI], 0.565-0.948; p = 0.018). There were no differences at 2 years between the MoM and MoP acetabular revisions in the incidence of dislocation, infection, or rerevision. When analyzed by patient sex and age group, there were more infections in the age 70 to 79 years MoP group compared with MoM (10 of 451 [5%] versus 29 of 628 [10%]; OR, 4.47; CI, 1.699-11.761; p = 0.001). There were high rates of dislocation, infection, and rerevision in both revision cohorts. The rate of dislocation was not greater after acetabular revision of MoM bearings at 2 years. Based on these findings, clinicians should counsel these patients preoperatively about the risks of these complications. Dual-mobility and constrained components have specific advantages and disadvantages in these settings and should be further studied. Level III, therapeutic study.
Prospective monitoring improves outcomes of primary total hip replacement: a cohort study
Streubel, Philipp N; Pachón, Marcela; Kerguelén, Carlos A; Navas, José; Portocarrero, Julio; Pesantez, Rodrigo F; Zayed, Gamal; Carrillo, Germán; Llinás, Adolfo M
2009-01-01
Background Over the past decade several studies have questioned current standards of patient safety in health care delivery. In response, our institution started a clinical pathway for total hip replacement in 1996. Prospective monitoring with regular feedback sessions to the individuals involved in patient care did however not start until 2003. The present study evaluates the effect of prospective monitoring on outcomes of total hip replacement. Methods Clinical records of patients undergoing primary elective total hip replacement between 1997 and 2004 were reviewed. Data on adverse events as well as adherence to protocols for venous thromboembolism prophylaxis were extracted retrospectively for the period 1997 to 2001 and prospectively from 2003 to 2004. Results were compared and analyzed in order to establish possible improvement in outcomes. Data was analyzed with Chi-square or Fisher's Exact test for categorical variables and Student's t-test for continuous variables. Alpha was set as less than 5% and analysis was performed with Stata 9.0 for Macintosh. Results Two-hundred and eighty-three patients were included from 1997 to 2001, and 62 from 2003 to 2004. Mean age, male to female ratio and initial diagnosis were similar in both groups. At least one adverse event occurred in 45% of patients in 1997–2001 and in 21% in 2003–2004 (p < 0.001). In-hospital hip dislocations occurred in 6% and 0% (p = 0.05), oliguria in 19% and 5% (p = 0.007), SSI and VTE in 3% and 0% (p = 0.37), adverse drug reactions in 11% and 13% (p = 0.66) and non-adherence to VTE prophylaxis protocols in 15% and 2% of cases respectively (p = 0.002). Conclusion Overall rate of adverse events as well as in-hospital hip dislocations, oliguria and non-adherence to VTE prophylaxis protocols were significantly reduced during the second period. We conclude that clinical pathways alone are insufficient to improve patient safety and require prospective monitoring and continuous feedback to health care providers in order to achieve the desired effect. PMID:19366438
Unconstrained tripolar hip implants: effect on hip stability.
Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan
2007-02-01
Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.
Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi
2017-02-01
The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.
Hermanns, Pia; Unger, Sheila; Rossi, Antonio; Perez-Aytes, Antonio; Cortina, Hector; Bonafé, Luisa; Boccone, Loredana; Setzu, Valeria; Dutoit, Michel; Sangiorgi, Luca; Pecora, Fabio; Reicherter, Kerstin; Nishimura, Gen; Spranger, Jürgen; Zabel, Bernhard; Superti-Furga, Andrea
2008-06-01
Deficiency of carbohydrate sulfotransferase 3 (CHST3; also known as chondroitin-6-sulfotransferase) has been reported in a single kindred so far and in association with a phenotype of severe chondrodysplasia with progressive spinal involvement. We report eight CHST3 mutations in six unrelated individuals who presented at birth with congenital joint dislocations. These patients had been given a diagnosis of either Larsen syndrome (three individuals) or humero-spinal dysostosis (three individuals), and their clinical features included congenital dislocation of the knees, elbow joint dysplasia with subluxation and limited extension, hip dysplasia or dislocation, clubfoot, short stature, and kyphoscoliosis developing in late childhood. Analysis of chondroitin sulfate proteoglycans in dermal fibroblasts showed markedly decreased 6-O-sulfation but enhanced 4-O-sulfation, confirming functional impairment of CHST3 and distinguishing them from diastrophic dysplasia sulphate transporter (DTDST)-deficient cells. These observations provide a molecular basis for recessive Larsen syndrome and indicate that recessive Larsen syndrome, humero-spinal dysostosis, and spondyloepiphyseal dysplasia Omani type form a phenotypic spectrum.
Dual Mobility Cemented Cups Have Low Dislocation Rates in THA Revisions
Langlais, Frantz L.; Gaucher, François; Musset, Thierry; Chaix, Olivier
2008-01-01
THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head ≥ 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108°). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65–86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196422
Levine, Brett R; Della Valle, Craig J; Deirmengian, Carl A; Breien, Kristoffer M; Weeden, Steven H; Sporer, Scott M; Paprosky, Wayne G
2008-12-01
A retrospective cohort study of 31 hips revised with a tripolar articular construct was performed. Patient demographics and preoperative and postoperative information were recorded. Indications for a tripolar construct were recurrent dislocation and the inability to attain intraoperative stability during hip revision. Nine patients (29%) were revised to the tripolar construct after failure of a constrained liner. Twenty patients (65%) had at least one episode of instability before the most recent revision. At a mean follow-up of 38 months, modified Postel scores improved from a mean of 5.28 to 9.64 (P < .01). Radiographic follow-up revealed no evidence of component loosening/migration, osteolysis, or polyethylene wear. Two patients (7%) required further revision surgery for recurrent instability. A tripolar construct was effective in eliminating or preventing instability in 93% of the complex cases treated. These early results support the use of a tripolar construct in treating recurrent instability or instability encountered at the time of revision hip arthroplasty.
Legenstein, R; Huber, W; Ungersboeck, A; Boesch, P
2006-01-01
From 1990 to 1991 we implanted 176 non-cemented proximal press-fit (PPF) total hip arthroplasties (THA) with ceramic-on-polyethylene articulation in 170 patients. Of these, 119 patients (122 THA) were followed from 104 to 129 months. Four cups have been revised for aseptic loosening, but revealed no radiolucencies of the stem. Two infections and two dislocations occurred. The median postoperative Harris hip score was 91. Ninety-eight per cent of the patients were satisfied with the outcome, 83% were free of pain and 67% walked without a limp. Serial radiographs showed stable fixation with bone ongrowth in nearly all arthroplasties except for four cups. Stem radiolucencies were first seen within 12 months, but were of no clinical relevance. Proximal periprosthetic bone resorption of the stem was seen in 18%. Radiolucencies occurred because of polyethylene debris-induced granulomas. The PPF system yields satisfactory long-term results in patients with primary and secondary hip osteoarthritis and dysplasia.
Magnetic resonance imaging with gadolinium arthrography to assess acetabular cartilage delamination.
Zaragoza, Edward; Lattanzio, Pierre-Jean; Beaule, Paul E
2009-01-01
Recent reports have demonstrated magnetic resonance imaging (MRI) as a promising technique in detecting articular cartilage lesions of the hip joint. The purpose of our study was to evaluate the diagnostic performance of MRI with gadolinium arthrography in detecting acetabular cartilage delamination in patients with pre-arthritic hip pain. 46 patients (48 hips) underwent surgical dislocation of the hip. Mean age was 38.8 (range 17-56). There were 26 males and 20 females. All patients had Magnetic Resonance Imaging with gadolinium arthrography (MRA) before undergoing open hip surgery where the acetabular cartilage was inspected. Acetabular cartilage delamination on MRA was seen on sagittal images as a linear intra-articular filling defect of low signal intensity >1mm in thickness on T1 weighted images and surrounded by contrast. On MRA all hips had a labral tear confirmed at surgery. At surgery 30 hips had evidence of acetabular cartilage delamination, 4 hips had ulceration and 14 had no articular cartilage damage. The majority of labral tears and cartilage damage were located in the antero-superior quadrant. The sensitivity and specificity of MRA detection of cartilage delamination confirmed at surgery were 97% and 84%, respectively. The positive and negative predictive values of the MRA finding were 90% and 94%, respectively. The presence of the acetabular cartilage delamination represents an early stage of articular cartilage degeneration. When evaluating a young adult with hip pain, labral tears in association with cartilage delamination should be considered. MRA represents an effective diagnostic tool.
TEM study on relationship between stacking faults and non-basal dislocations in Mg
NASA Astrophysics Data System (ADS)
Zhang, Dalong; Jiang, Lin; Schoenung, Julie M.; Mahajan, Subhash; Lavernia, Enrique J.
2015-12-01
Recent interest in the study of stacking faults and non-basal slip in Mg alloys is partly based on the argument that these phenomena positively influence mechanical behaviour. Inspection of the published literature, however, reveals that there is a lack of fundamental information on the mechanisms that govern the formation of stacking faults, especially I1-type stacking faults (I1 faults). Moreover, controversial and sometimes contradictory mechanisms have been proposed concerning the interactions between stacking faults and dislocations. Therefore, we describe a fundamental transmission electron microscope investigation on Mg 2.5 at. % Y (Mg-2.5Y) processed via hot isostatic pressing (HIP) and extrusion at 623 K. In the as-HIPed Mg-2.5Y, many
[Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].
Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua
2017-12-25
To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.
[Which hip articulation bearing for which patient? : Tribology of the future].
Morlock, M M; Bishop, N; Kaddick, C
2011-12-01
Replacement of the hip joint has become an exceptionally successful procedure since the inauguration of the low friction principle by Charnley. Aseptic osteolysis and joint dislocation have been addressed by the development of wear-optimized materials and the introduction of larger heads. As an increase in head diameter against polyethylene causes wear increase, larger hard-on-hard bearings were introduced, which exhibit reduced wear and reduced dislocation risk with increasing head diameter. These findings were derived from standard simulator testing, not sufficiently considering the risk of fluid film breakdown under adverse conditions, which can cause a dramatic increase in wear and friction proportional to the head diameter. Such adverse conditions can occur clinically in patients due to several factors and have caused the presently observed unexpected problems with these new designs. Standardized preclinical testing has to be viewed as a minimum requirement but certainly not as a guarantee for the clinical success of new materials and designs even if the testing is adapted to the current patient requirements, which is presently not the case. The future of tribology lies in the prevention of adverse conditions in patients, the improvement and optimized use of proven existing materials and not in the use of new materials.
Microstructure and Charpy impact properties of 12 14Cr oxide dispersion-strengthened ferritic steels
NASA Astrophysics Data System (ADS)
Oksiuta, Z.; Baluc, N.
2008-02-01
This paper describes the microstructure and Charpy impact properties of 12-14 Cr ODS ferritic steels fabricated by mechanical alloying of pure Fe, Cr, W, Ti and Y 2O 3 powders in a Retsch ball mill in argon atmosphere, followed by hot isostatic pressing at 1100 °C under 200 MPa for 4 h and heat treatment at 850 °C for 1 h. Weak Charpy impact properties were obtained in the case of both types of as-hipped materials. In the case of 14Cr materials, the weak Charpy properties appeared related to a bimodal grain size distribution and a heterogeneous dislocation density between the coarse and fine grains. No changes in microstructure were evidenced after heat treatment at 850 °C. Significant improvement in the transition temperature and upper shelf energy of 12Cr materials was obtained by heat treatment at 850 °C for 1 h, which was attributed to the formation of smaller grains, homogenous in size and containing fewer dislocations, with respect to the as-hipped microstructure. This modified microstructure results in a good compromise between strength and Charpy impact properties.
Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian
2017-01-01
Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698
Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.
Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola
2012-01-01
The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).
Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.
Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.
Kang, Jeong Hoon; Lee, Sang Hong; Jung, Sung
2015-12-01
The current study aims to evaluate the clinical and the radiological outcome of bipolar hemiarthroplasty using cementless cone stem to treat osteoporotic femoral neck fracture and compare the results according to the proximal femur geometry. Seventy-five hips (75 patients) that underwent bipolar hemiarthroplasty with cementless cone stem between September 2006 and December 2011 were analyzed. The minimum follow-up period was 3 years. Thirty-three hips were classified as type B and 41 as type C. The clinical outcome was assessed using Harris hip score and the walking ability score. Radiographic evaluation was performed to evaluate the stability of the prosthesis. At the most recent follow up, the mean Harris hip score was 86 (range, 70-92) and 65% recovered to preoperative ambulatory status. In the radiographic exam, stable stem fixation was achieved in all cases. For the complications, eight hips developed deep vein thrombosis while three hips showed heterotopic ossification. Dislocation and delayed deep infection occurred in one hip resepectively. There were no significance differences in Harris hip score and walking ability score when the type B group was compare with the type C. Bipolar hemiarthroplasty with cementless cone stem showed an excellent early outcome both clinically and radiographically regardless of the shape of the proximal femur. We believe this prosthesis can provide early stability to the Dorr type B and C femur and is an effective treatment for treating osteoporotic femoral neck fracture.
Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.
Chughtai, Morad; Mistry, Jaydev B; Diedrich, Aloise M; Jauregui, Julio J; Elmallah, Randa K; Bonutti, Peter M; Harwin, Steven F; Malkani, Arthur L; Kolisek, Frank R; Mont, Michael A
2016-10-01
Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting. (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA? Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded. The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494-4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and stem; and two patients had periprosthetic infections that were treated with two-stage revisions. There were no dislocations. Patients had a mean HHS of 94 (SD, 6) at final followup. On radiographic evaluation, no progressive radiolucencies or positional changes of the components were identified. Surgical complications included one traumatic avulsion of the abductors, one traumatic avulsion of the greater trochanter, which was repaired without revision of any of the components, and one loose femoral stem, which required revision of the femoral component only. Dual-mobility cups in primary THA yield seemingly comparable survivorship and complications to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings, larger, longer term, comparative-and ideally, randomized-trials will be needed to establish the superiority of one approach over the other. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols. Level IV, therapeutic study.
High-impact sport after hip resurfacing: The Ironman triathlon.
Girard, J; Lons, A; Pommepuy, T; Isida, R; Benad, K; Putman, S
2017-09-01
Returning to high-impact sport is an increasingly frequent functional demand following hip replacement. The literature, however, is sparse on the subject and nonexistent regarding triathlon. We therefore conducted a retrospective study of hip resurfacing in triathlon players, to determine: (1) whether it is possible to return to this kind of sport; (2) if so, whether it is possible to return to the same level; and (3) how a resurfaced hip behaves under these conditions. Hip resurfacing allows return to competition level in long-distance triathlon. A single-center single-operator retrospective study included patients undergoing hip resurfacing with the Conserve Plus implant inserted through a posterolateral approach, who had ceased long-distance triathlon practice due to osteoarthritis of the hip. Fifty-one of the 1688 patients undergoing resurfacing during the inclusion period were long-distance triathlon players. The series comprised 48 patients: 51 implants; 43 male, 5 female; mean age, 44.8 years (range, 28.2-58.9 years). At a mean 4.7 years' follow-up (range, 2.2-7.6 years), all clinical scores showed significant improvement; Merle d'Aubigné and Harris scores rose respectively from 12.3 (5-16) and 42 (37-56) preoperatively to 17.5 (13-18) and 93.2 (73-100) (P<0.001). There were no cases of dislocation or implant revision. Forty-five patients returned to sport (94%). Rates of return to swimming, cycling and running were respectively 38/48 (79%), 41/48 (85%) and 33/48 (69%). Preoperatively, all patients had taken part in at least 1 competition: 29 with distance=70.3km and 19 with distance=140.6km. At follow-up, 28 patients had taken part in an Ironman competition: 21 with distance=70.3km and 7 with distance=140.6km. Mean competition performance did not differ between pre and postoperative periods. Return-to-sport rates were good following hip resurfacing. Non-impact sports (swimming, cycling) predominated postoperatively, whereas the rate of impact sport (running) diminished. Return to competition-level sport (extreme triathlon) was possible for 28/48 patients (58%). Implant survival seemed unaffected by this high-impact sports activity at a mean 4.7 years' follow-up. IV, retrospective, non-controlled. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
3D surgical printing and pre contoured plates for acetabular fractures.
Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Gil, Pablo; Martínez-Gómiz, José María; Vaquero-Martín, Javier
2016-11-01
We describe the methodical and possibilities of 3D surgical printing in preoperative planning of acetabular fractures showing a case of a 45-year-old with an associated transverse fracture of the left acetabulum with posterior wall fracture, with multiple fragments, and posterior ipsilateral hip dislocation, defending the do it your-self mode. Copyright © 2016 Elsevier Ltd. All rights reserved.
Haen, T X; Lonjon, G; Vandenbussche, E
2015-12-01
Cemented versions of dual-mobility cups (DMCs), helpful in cases of bone stock alteration, are usually used in association with a reinforcement device. To simplify the intervention in elderly subjects or those with a poor bone stock, the cups can be cemented directly into the bone, but the long-term result remains uncertain. We conducted a retrospective study in this population so as to: (1) assess whether cemented fixation of a DMC without a reinforcement device leads to a higher loosening rate, (2) confirm its efficacy in preventing dislocations in subjects at high risk of instability, and (3) measure the functional results. Cemented fixation of a DMC is reliable in cases of moderate alteration of bone stock. Sixty-four patients (66 hips) undergoing implantation of a cemented DMC (Saturne™) without a reinforcement device were included in this single-center retrospective study. Their mean age was 79.8 years (range, 40-95 years). The indications varied: hip osteoarthritis (30.3%), prosthesis revision (44.0%), and trauma (25.8%). The patients were evaluated radiologically and clinically at follow-up. The main evaluation criterion was the revision rate for aseptic loosening. Dislocations, the infection rate, and the Postel Merle d'Aubigné (PMA) score were noted. At the mean follow-up of 4.2 years, three (4.6%) patients had been lost to follow-up and 22 (33.3%) had died. There was one case of aseptic loosening (1.5%). Cup survival was 98% at 5 years (95%CI [94-100]). There were no dislocations. There was one revision for infection. The mean PMA score was 15.5 (range, 9-18). The frequency of acetabular loosening was comparable to the frequency in cemented DMCs with a reinforcement device. A cemented DMC without a reinforcement device is possible and is a simple and viable option when there is moderate bone stock alteration. IV, retrospective cohort study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Song, Xinggui; Ni, Ming; Li, Heng; Li, Xin; Li, Xiang; Fu, Jun; Chen, Jiying
2018-05-23
The impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (THA) is not well studied. The aim of our study is to investigate the difference of cup orientation in bilateral THA performed by right-handed surgeons using posterolateral approach and which cup could be fitter to Lewinneck's safe zone. The study consisted of 498 patients that underwent bilateral THA by three right-handed surgeons in our hospital. Postoperative acetabular cup anteversion and abduction on an anteroposterior pelvic radiograph were measured by Orthoview software (Orthoview LLC, Jacksonville, Florida). Furthermore, the percentage of cup placement within the safe zone was compared. The mean anteversion was 25.28 (25.28° ± 7.16°) in left THA and 22.01 (22.01° ± 6.35°) in right THA (p < 0.001). The mean abduction was 37.50 (37.50° ± 6.76°) in left THA and 38.59 (38.59° ± 6.84°) in right THA (p = 0.011). In the left side, the cup was positioned in Lewinnek's safe zone in 52% for anteversion, 87% for abduction, and 46% for both anteversion and abduction. But the cup placement within Lewinnek's safe zone was 71, 88, and 62% in the right side, respectively. There were significant differences in the percentage of acetabular cup placement within the safe zone for anteversion (p < 0.001) and for both anteversion and inclination (p < 0.001). Dislocation occurred in 7.0% (35/498) of cases in left THA and 3.2% (16/498) in right THA. The percentages of patients experiencing dislocation were significantly different between the two sides (p = 0.006). This current study demonstrated that surgeon handedness is likely to be a contributing factor that affects cup inclination and anteversion in bilateral THA and that the placement of cup performed by dominant hands of surgeons is more accurate than that performed by non-dominant sides.
The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.
Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner
2016-07-01
The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.
[Classification and Treatment of Sacroiliac Joint Dislocation].
Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo
2017-09-01
To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100% fracture healing. Two cases were identified as type Ⅰ sacroiliac joint dislocation,including one with coexistence of nerve injury. Patients recovered completely 12 months after surgery. Eight cases were identified as type Ⅱ sacroiliac joint dislocation; none had obvious nerve injury during treatments. Twelve cases were identified as type Ⅲ sacroiliac joint dislocation,including one with coexistence of nerve injury. Patients recovered completely 12 months after surgery. Three cases were identified as type Ⅳ sacroiliac joint dislocation with coexistence of nerve injury. Two patients fully recovered 12 months after surgery. One had partial recovery of neurological function. The classification and treatment regimen for sacroiliac joint dislocation have achieved better therapeutic effect,which is worth promoting.
Interventions for Hip Pain in the Maturing Athlete
Gomberawalla, M. Mustafa; Kelly, Bryan T.; Bedi, Asheesh
2014-01-01
Context: Femoroacetabular impingement (FAI) alters hip mechanics, results in hip pain, and may lead to secondary osteoarthritis (OA) in the maturing athlete. Hip impingement can be caused by osseous abnormalities in the proximal femur or acetabulum. These impingement lesions may cause altered loads within the hip joint, which result in repetitive collision damage or sheer forces to the chondral surfaces and acetabular labrum. These anatomic lesions and resultant abnormal mechanics may lead to early osteoarthritic changes. Evidence Acquisition: Relevant articles from the years 1995 to 2013 were identified using MEDLINE, EMBASE, and the bibliographies of reviewed publications. Level of Evidence: Level 4. Results: Improvements in hip arthroscopy have allowed FAI to be addressed utilizing the arthroscope. Adequately resecting the underlying osseous abnormalities is essential to improving hip symptomatology and preventing further chondral damage. Additionally, preserving the labrum by repairing the damaged tissue and restoring the suction seal may theoretically help normalize hip mechanics and prevent further arthritic changes. The outcomes of joint-preserving treatment options may be varied in the maturing athlete due to the degree of underlying OA. Irreversible damage to the hip joint may have already occurred in patients with moderate to advanced OA. In the presence of preexisting arthritis, these patients may only experience fair or even poor results after hip arthroscopy, with early conversion to hip replacement. For patients with advanced hip arthritis, total hip arthroplasty remains a treatment option to reliably improve symptoms with good to excellent outcomes and return to low-impact activities. Conclusion: Advances in the knowledge base and treatment techniques of intra-articular hip pain have allowed surgeons to address this complex clinical problem with promising outcomes. Traditionally, open surgical dislocations for hip preservation surgery have shown good long-term results. Improvements in hip arthroscopy have led to outcomes equivalent to open surgery while utilizing significantly less invasive techniques. However, outcomes may ultimately depend on the degree of underlying OA. When counseling the mature athlete with hip pain, an understanding of the underlying anatomy, degree of arthritis, and expectations will help guide the treating surgeon in offering appropriate treatment options. PMID:24427445
Kim, Y-H
2008-03-01
This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.
Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E
2008-07-01
The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.
Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan
2016-06-01
We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.
Anwander, Helen; Siebenrock, Klaus A; Tannast, Moritz; Steppacher, Simon D
2017-04-01
Since the importance of an intact labrum for normal hip function has been shown, labral reattachment has become the standard method for open or arthroscopic treatment of hips with femoroacetabular impingement (FAI). However, no long-term clinical results exist evaluating the effect of labral reattachment. A 2-year followup comparing open surgical treatment of FAI with labral resection versus reattachment was previously performed at our clinic. The goal of this study was to report a concise followup of these patients at a minimum of 10 years. We asked if patients undergoing surgical hip dislocation for the treatment of mixed-type FAI with labral reattachment compared with labral resection had (1) improved hip pain and function based on the Merle d'Aubigné-Postel score; and (2) improved survival at 10-year followup. Between June 1999 and July 2002, we performed surgical hip dislocation with femoral neck osteoplasty and acetabular rim trimming in 52 patients (60 hips) with mixed-type FAI. In the first 20 patients (25 hips) until June 2001, a torn labrum or a detached labrum in the area of acetabular rim resection was resected. In the next 32 patients (35 hips), reattachment of the labrum was performed. The same indications were used to perform both procedures during the periods in question. Of the 20 patients (25 hips) in the first group, 19 patients (95%) (24 hips [96%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 13 years; range, 12-14 years). Of the 32 patients (35 hips) in the second group, 29 patients (91%) (32 hips [91%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 12 years; range, 10-13 years). We used the anterior impingement test to assess pain. Function was assessed using the Merle d'Aubigné- Postel score and ROM. Survivorship calculation was performed using the method of Kaplan-Meier with failure defined as conversion to THA, progression of osteoarthritis (of one grade or more on the Tönnis score), and a Merle d'Aubigné-Postel score < 15. At the 10-year followup, hip pain in hips with labral reattachment was slightly improved for the postoperative Merle d'Aubigné-Postel pain subscore (5.0 ± 1.0 [3-6] versus 3.9 ± 1.7 [0-6]; p = 0.017). No difference existed for the prevalence of hip pain assessed using the anterior impingement test with the numbers available (resection group 52% [11 of 21 hips] versus reattachment group 27% [eight of 30 hips]; odds ratio, 3.03; 95% confidence interval [CI], 0.93-9.83; p = 0.062). Function was slightly better in the reattachment group for the overall Merle d'Aubigné-Postel score (16.7 ± 1.5 [13-18] versus 15.3 ± 2.4 [9-18]; p = 0.028) and hip abduction (45° ± 13° [range, 30°-70°] versus 38° ± 8° [range, 25°-45°]; p = 0.001). Hips with labral reattachment showed a better survival rate at 10 years than did hips that underwent labral resection (78%; 95% CI, 64%-92% versus 46%, 95% CI, 26%-66%; p = 0.009) with the endpoints defined as conversion to THA, progression of osteoarthritis, and a Merle d'Aubigné-Postel score < 15. With isolated endpoints, survival at 10 years was increased for labral reattachment and the endpoint Merle d'Aubigné score < 15 (83%, 95% CI, 70%-97% versus 48%, 95% CI, 28%-69%; p = 0.009) but did not differ for progression of osteoarthritis (83%, 95% CI, 68%-97% versus 81%, 95% CI, 63%-98%; p = 0.957) or conversion to THA (94%, 95% CI, 86%-100% versus 87%, 95% CI, 74%-100%; p = 0.366). The current results suggest the importance of preserving the labrum and show that resection may put the hip at risk for early deterioration. At 10-year followup, hips with labral reattachment less frequently had a decreased Merle d'Aubigné score but no effect on progression of osteoarthritis or conversion to THA could be shown. Level III, therapeutic study.
The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.
Lachiewicz, P F; Watters, T S
2016-01-01
The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. ©2016 The British Editorial Society of Bone & Joint Surgery.
[Acetabuloplasty in cerebral palsy patients].
Schejbalová, A; Chládek, P
2007-12-01
Acetabuloplasty as an isolated surgical procedure is one of the options allowing for hip joint realignment in cerebral palsy patients. Also, it is often involved in combined techniques used for hip joint reconstruction. In the years 2004-2005, 20 cerebral palsy patients, aged from 4 to 13 years, were indicated for acetabuloplasty. The group included children with varying degrees of locomotor disability, ranging from inability even to crawl to ability to move without support (stages 2 to 7 on the Vojta scale). Clinical and X-ray findings were evaluated at 2 and 6 months after surgical treatment and then every 6 months of follow- up. The X-ray finding was described by means of CE angle (Wiberg) values and hip migration percentage. Of 21 hips (in 20 patients) treated by acetabuloplasty in our modification during the two years, one developed recurrent dorsal dislocation which was possible to deal with by conservative treatment. All hips pre-operatively categorized as group B or group C were post-operatively assessed as group A hips. Subsequent migration of the acetabulum occurred within a year in two patients with distinct original asymmetry. Surgery on bones comprising the hip joint in cerebral palsy patients is indicated according to the degree of lateral migration and changes in hip joint geometry involving the proximal femur or pelvis, or in combination with open reduction. Acetabuloplasty is indicated as an isolated procedure or as part of combined techniques leading to a better coverage of the hip joint. It is recommended for children up to 10 years of age, but also older ones, in whom the flexibility of child bones enables us to do without internal osteosynthesis. Acetabuloplasty is indicated as an isolated surgical procedure for hip joint subluxation in cerebral palsy children. It has no adverse effects on hip abductors that, in cerebral palsy patients, are 85 % insufficient. It improves hip joint symmetry and helps to avoid more demanding reconstructive or palliative procedures. Key words: cerebral palsy, acetabuloplasty, lateral migration.
Adverse Outcomes in Infantile Bilateral Developmental Dysplasia of the Hip.
Morbi, Abigail H M; Carsi, Belen; Gorianinov, Vitalli; Clarke, Nicholas M P
2015-01-01
It is believed that bilateral developmental dysplasia of the hip (DDH) has poorer outcomes with higher rates of avascular necrosis (AVN) and reintervention, compared with unilateral DDH. However, there is limited evidence in the literature, with few studies looking specifically at bilateral cases. A retrospective review of 36 patients (72 hips) with >4 years of follow-up. Patient population included surgically treated DDH including late presentations and failures of conservative treatment. The dislocated hips underwent either simultaneous closed or 1 open and 1 closed, or sequential open reduction. AVN and secondary procedures were used as endpoints for analysis as well as clinical and radiologic outcomes. At the last follow-up, 33% of hips had radiologic signs of AVN. Those hips that had no ossific nucleus (ON) at the time of surgery had an odds ratio of developing AVN of 3.05 and a statistically significant association between the 2 variables, whereas open/closed or simultaneous/sequential reduction did not increase the risk for AVN. In addition, 45.8% of those hips required further surgery. The estimated odds ratio of needing additional surgery after simultaneous reduction was 4.04. Clinically, 79.2% of the hips were graded as McKay I, whereas radiologically only 38.8% were Severin I. The AVN rate in bilateral DDH treated surgically is greater than the rate noted in unilateral cases from the same institution undergoing identical protocols. There was no difference in AVN rates between simultaneous and sequential or between the first and second hip to be sequentially reduced. Presence of ON decreases the risk for AVN, suggesting that in bilateral cases, awaiting the appearance of the ON is an important tool to reduce the incidence of AVN. IV.
Short-term clinical experience with hip resurfacing arthroplasty.
Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna
2007-01-01
This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.
Hip pathology in Majewski osteodysplastic primordial dwarfism type II.
Karatas, Ali F; Bober, Michael B; Rogers, Kenneth; Duker, Angela L; Ditro, Colleen P; Mackenzie, William G
2014-09-01
Majewski osteodysplastic primordial dwarfism type II (MOPDII) is characterized by severe prenatal and postnatal growth failure with microcephaly, characteristic skeletal dysplasia, an increased risk for cerebrovascular disease, and insulin resistance. MOPDII is caused by mutations in the pericentrin (PCNT) gene and is inherited in an autosomal-recessive manner. This study aimed to determine the incidence of hip pathology in patients with molecularly confirmed MOPDII and to describe the functional outcomes of surgical treatment. Thirty-three enrolled patients had a clinical diagnosis of MOPDII. Biallelic PCNT mutations or absent pericentrin protein was confirmed in 25 of these patients. Twelve patients (7 female) had appropriate clinical and radiographic records at this institution and were included in this study. The data collected included age at presentation, age at surgery, sex, body weight and height, weight-bearing status at diagnosis, and the clinical examination. Four patients (31%) had coxa vara: 3 unilateral and 1 bilateral. Three unilateral patients had in situ pinning at a mean age 4 years. The patient with bilateral coxa vara had valgus osteotomy at the age of 5 years. Two children had bilateral hip dysplasia and subluxation with no surgery. One patient had bilateral developmental hip dislocations. The patient was treated by open reduction-spica cast and 2 years after surgery, coxa valga was noted. Another patient was diagnosed at an age of 12 years with bilateral avascular necrosis of the hips. Four patients did not have hip pathology. Hip pathology is common among children with MOPDII; coxa vara is the most frequent diagnosis. Routine clinical and radiographic hip evaluation is important. The capital femoral epiphysis appears to slip down along the shaft, giving the appearance of a proximal femoral epiphysiolysis. A hip diagnosed with slipped capital femoral epiphysis in early life may progress to severe coxa vara. Level IV.
Paleoepidemiolgical patterns of trauma in a prehistoric population from central California.
Jurmain, R
2001-05-01
Skeletal trauma was investigated in a large collection of human remains from central California (N = 162 aged and sexed adults). Lesions investigated included cranial and long bone fractures, projectile wounds, and dislocation. Long bone fractures were found in 10.5% of individuals; overall, incidence by element was 2.3%. In addition, cranial injuries were found in 4.4% of complete adult crania. Projectile wounds were seen unambiguously in four individuals (with embedded obsidian fragments) and strongly suggested in two other individuals with partially healed lesions. Finally, one case of traumatic hip dislocation was also observed. In both incidence and patterning of injuries, this population is similar to other archeological groups from California. This evidence further supports earlier reports indicating that interpersonal aggression was quite common in prehistoric California.
Hip resurfacing: a large, US single-surgeon series.
Brooks, P J
2016-01-01
Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants. Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid-term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system. ©2016 The British Editorial Society of Bone & Joint Surgery.
Can, Ata; Sarikaya, Ilker A; Yontar, Necip S; Erdogan, Ayse O; Gorgun, Baris; Erdogan, Fahri
2018-05-01
We argue that 1-stage bilaterally total hip arthroplasty (THA) could be acceptable in bilateral coxarthrosis because of high-riding developmental dysplasia of the hip (DDH). Sixty-nine cases (51 patients) of high-riding DDH in patients who underwent THA from 2010 to 2013 were reviewed. Patients were divided into 2 groups: unilateral (group 1) and 1-stage bilateral surgery (group 2). The clinical measurements were the visual analog scale and Harris Hip Score. The average follow-up was 37.3 months for group 1 and 38.8 months for group 2. The hospital stay time was 5.2 days in group 1 and 6.2 days in group 2 (P = .334). The mean Harris Hip Score and visual analog scale score were improved significantly after surgery for both groups, and there was no statistically significant difference (P = .988). There was no difference between groups 1 and 2 in terms of complications (P = .137). Our data confirm that 1-stage bilateral transverse osteotomy with THA is an effective method as unilateral and it does not increase the length of patients' hospital stays and features a low risk of postoperative complications in the treatment of patients with high-riding DDH. Copyright © 2017 Elsevier Inc. All rights reserved.
Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model
Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672
Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.
Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T
2014-04-01
Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.
Socolovsky, Mariano; Masi, Gilda Di
2012-01-01
Background: Dissecting through the gluteus maximus muscle by splitting its fibers, instead of complete sectioning of the muscle, is faster, involves less damage to tissues, and diminishes recovery time. The objective of the current paper is to present a clinical series of sciatic nerve lesions where the nerve was sufficiently exposed via the transgluteal approach. Methods: We retrospectively selected 18 traumatic sciatic nerve lesions within the buttock, operated upon from January 2005 to December 2009, with a minimum follow-up of 2 years. In all patients, a transgluteal approach was employed to explore and reconstruct the nerve. Results: Ten males and eight females, with a mean age of 39.7 years, were studied. The etiology of the nerve lesion was previous hip surgery (n = 7), stab wound (n = 4), gunshot wound (n = 3), injection (n = 3), and hip dislocation (n = 1). In 15 (83.3%) cases, a motor deficit was present; in 12 (66.6%) cases neuropathic pain and in 12 (66.6%) cases sensory alterations were present. In all cases, the transgluteal approach was adequate to expose the injury and treat it by neurolysis alone (10 cases), neurolysis and neurorrhaphy (4 cases), and reconstruction with grafts (4 cases; three of these paired with neurolysis). The mean pre- and postoperative grades for the tibial nerve (LSUHSC scale) were 1.6 and 3.6, respectively; meanwhile, for the peroneal division, preoperative grade was 1.2 and postoperative grade was 2.4. Conclusions: The transgluteal approach adequately exposes sciatic nerve injuries of traumatic origin in the buttock and allows for adequate nerve reconstruction without sectioning the gluteus maximus muscle. PMID:22439106
Khanna, Vickas; Harris, Adam; Farrokhyar, Forough; Choudur, Hema N; Wong, Ivan H
2014-03-01
The purpose of this study was to document and compare the incidence of intra-articular hip pathologic findings identified using arthroscopy versus conventional imaging in patients with acute trauma to the hip. This was a blinded prospective case series study designed to review the incidence of intra-articular pathologic disorders in patients with post-traumatic injury between the ages of 18 and 65 years who were referred to a single surgeon. Injuries included hip dislocation, proximal femur fracture, pelvic ring fracture, acetabular fracture, penetrating injury (gunshot wound), and soft tissue injury. Preoperative radiographs, computed tomographic (CT) scans, or magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) scans (or a combination of these) were obtained. Findings were documented and compared with intraoperative findings. A total of 29 post-traumatic hips were enrolled in this study. Hip arthroscopy identified 17 of 29 hips (59%) as having loose bodies, 11 of 29 (38%) hips as having an intra-articular step deformity, 14 of 29 (49%) hips as having an osteochondral lesion, and 27 of 29 (93%) hips as having a labral tear. Plain radiographs and CT scans yielded low sensitivity when compared with arthroscopy for the identification of loose bodies and step deformities. MRI/MRA comparison with arthroscopic findings suggest that MRI/MRA is an accurate tool for identification of labral tears, because 91% of tears seen on arthroscopy were also identified by MRI/MRA. In 4 hips, however, MRI/MRA failed to identify osteochondral lesions that were subsequently identified by arthroscopy. Traumatic injuries of the hip result in substantial intra-articular pathologic findings, including loose bodies, labral tears, step deformities, and osteochondral lesions. The arthroscope is a powerful tool in identifying these injuries. Plain radiographs and CT scans appear to underestimate the true incidence of loose bodies and step deformities within the joint when compared with hip arthroscopy after a traumatic injury of the hip. Level IV, diagnostic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.
Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki
2010-04-01
Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Cobalt toxicity after revision total hip replacement due to fracture of a ceramic head.
Pelayo-de Tomás, J M; Novoa-Parra, C; Gómez-Barbero, P
Symptomatic cobalt toxicity from a failed total hip replacement is a rare, but devastating complication. Potential clinical findings include cardiomyopathy, hypothyroidism, skin rash, visual and hearing impairment, polycythaemia, weakness, fatigue, cognitive impairment, and neuropathy. The case is presented of a 74year-old man in whom, after a ceramic-ceramic replacement and two episodes of prosthetic dislocation, it was decided to replace it with a polyethylene-metal total hip arthroplasty (THA). At 6months after the revision he developed symptoms of cobalt toxicity, confirmed by analytical determination (serum cobalt level=651.2μg/L). After removal of the prosthesis, the levels of chromium and cobalt in blood and urine returned to normal, with the patient currently being asymptomatic. It is recommended to use a new ceramic on ceramic bearing at revision, in order to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Probing the character of ultra-fast dislocations
Rudd, R. E.; Ruestes, C. J.; Bringa, E. M.; ...
2015-11-23
Plasticity is often controlled by dislocation motion, which was first measured for low pressure, low strain rate conditions decades ago. However, many applications require knowledge of dislocation motion at high stress conditions where the data are sparse, and come from indirect measurements dominated by the effect of dislocation density rather than velocity. Here we make predictions based on atomistic simulations that form the basis for a new approach to measure dislocation velocities directly at extreme conditions using three steps: create prismatic dislocation loops in a near-surface region using nanoindentation, drive the dislocations with a shockwave, and use electron microscopy tomore » determine how far the dislocations moved and thus their velocity at extreme stress and strain rate conditions. We report on atomistic simulations of tantalum that make detailed predictions of dislocation flow, and find that the approach is feasible and can uncover an exciting range of phenomena, such as transonic dislocations and a novel form of loop stretching. Furthermore, the simulated configuration enables a new class of experiments to probe average dislocation velocity at very high applied shear stress.« less
[Results and experiences of conversion of hip arthrodesis ].
Schuh, A; Zeiler, G; Werber, S
2005-03-01
With the predictably good outcome of total hip arthroplasty today (THA), hip arthrodesis currently has limited indications. Over the long term, however, most patients develop secondary degenerative arthritis in the spine, contralateral hip, and ipsilateral knee due to overloading. The deteriorating condition of these joints eventually causes the onset of pain, which often requires conversion of a fused hip to a THA. The results and experiences of conversions of a hip arthrodesis into a THA are reported. Between 1 January 1985 and 31 December 2001 conversion of a previously performed arthrodesis of the hip to THA was carried out in a total of 45 patients; 34 patients could be followed up after the conversion to THA after a mean of 77.5 months (min.: 24, max.: 208). The primary indications for the conversion were low back pain (n=21) and ipsilateral knee pain (n=13). The mean age at the time of THA was 75.3 years (min.: 32, max.: 74). The mean time interval between the arthrodesis and the conversion to THA was 30.4 years (min.: 5, max.: 66). Of 34 hips, 29 (85%) were either pain free or had minimal pain. Complications included one persisting sciatic nerve palsy, two superficial infections, two periprosthetic fractures, and two heterotopic ossifications IV degrees with one recurrence of ankylosis and one marked reduction of motion. Revision arthroplasty was performed in four hips. Postoperatively 7 patients showed no limping, 11 showed a slight limp, and 17 a pronounced limp. Recurrent dislocations occurred in one patient. We conclude that this operation can lead to satisfactory results even after a long duration of the arthrodesis. There is a high rate of complications after conversion of a hip arthrodesis to a total hip arthroplasty. These issues must be carefully considered and discussed with the patient before any conversion procedure.
[Joint dislocation after total knee arthroplasty as an ankle fracture complication. Case report].
Hrubina, M; Skoták, M
2012-01-01
Joint dislocation after total knee arthroplasty is a rare complication. It is described as the result of ligamentous instability. Here we report the case of an 82-year-old women who underwent primary total knee arthroplasty (TKA) for advanced primary grade III gonarthrosis. At 3 post-operative months the joint was stable and painless, with radiographic evidence of good TKA alignment and integration. At 4 months the patient suffered injury to the ankle involving a bimalleolar fracture and damage to knee soft tissues. The fracture was surgically treated. Subsequently, dorsal tibial dislocation was manifested. This was managed by individual intramedullary nail arthrodesis. At 8 months following the operation, the knee condition was satisfactory, with rigid arthrodesis and leg shortening of 4 cm. The patient was satisfied because she was free of pain and able to walk. Arthrodesis of the knee joint with an individual nail is an option for a definitive treatment of TKA instability. When other joints, such as ankle or hip joints, are injured, it is recommended to pay attention also to any TKA implanted previously because of potential development of instability or infection.
Biver, A; De Rijcke, S; Toppet, V; Ledoux-Corbusier, M; Van Maldergem, L
1994-06-01
We present a female infant exhibiting congenital cutis laxa with retardation of growth and motor development, ligamentous laxity and congenital dislocation of the hips. This connective tissue disorder was associated with Dandy-Walker malformation, atrial and ventricular defect and minor bone abnormalities including multiple wormian bones, abnormal tubulation of long bones and absent twelfth pair of ribs. This association is believed to be unique.
Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan
2005-07-01
Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.
Size dependence of yield strength simulated by a dislocation-density function dynamics approach
NASA Astrophysics Data System (ADS)
Leung, P. S. S.; Leung, H. S.; Cheng, B.; Ngan, A. H. W.
2015-04-01
The size dependence of the strength of nano- and micron-sized crystals is studied using a new simulation approach in which the dynamics of the density functions of dislocations are modeled. Since any quantity of dislocations can be represented by a density, this approach can handle large systems containing large quantities of dislocations, which may handicap discrete dislocation dynamics schemes due to the excessive computation time involved. For this reason, pillar sizes spanning a large range, from the sub-micron to micron regimes, can be simulated. The simulation results reveal the power-law relationship between strength and specimen size up to a certain size, beyond which the strength varies much more slowly with size. For specimens smaller than ∼4000b, their strength is found to be controlled by the dislocation depletion condition, in which the total dislocation density remains almost constant throughout the loading process. In specimens larger than ∼4000b, the initial dislocation distribution is of critical importance since the presence of dislocation entanglements is found to obstruct deformation in the neighboring regions within a distance of ∼2000b. This length scale suggests that the effects of dense dislocation clusters are greater in intermediate-sized specimens (e.g. 4000b and 8000b) than in larger specimens (e.g. 16 000b), according to the weakest-link concept.
Sports Injuries about the Hip: What the Radiologist Should Know.
Hegazi, Tarek M; Belair, Jeffrey A; McCarthy, Eoghan J; Roedl, Johannes B; Morrison, William B
2016-10-01
Injuries of the hip and surrounding structures represent a complex and commonly encountered scenario in athletes, with improper diagnosis serving as a cause of delayed return to play or progression to a more serious injury. As such, radiologists play an essential role in guiding management of athletic injuries. Familiarity with hip anatomy and the advantages and limitations of various imaging modalities is of paramount importance for accurate and timely diagnosis. Magnetic resonance (MR) imaging is often the modality of choice for evaluating many of the injuries discussed, although preliminary evaluation with conventional radiography and use of other imaging modalities such as ultrasonography (US), computed tomography, and bone scintigraphy may be supplementary or preferred in certain situations. Stress fractures, thigh splints, and posterior hip dislocations are important structural injuries to consider in the athlete, initially imaged with radiographs and often best diagnosed with MR imaging. Apophyseal injuries are particularly important to consider in young athletes and may be acute or related to chronic repetitive microtrauma. Femoroacetabular impingement has been implicated in development of labral tears and cartilage abnormalities. Tear of the ligamentum teres is now recognized as a potential cause of hip pain and instability, best evaluated with MR arthrography. Greater trochanteric pain syndrome encompasses a group of conditions leading to lateral hip pain, with US playing an increasingly important role for both evaluation and image-guided treatment. Muscle injuries and athletic pubalgia are common in athletes. Lastly, snapping hip syndrome and Morel-Lavallée lesions are two less common but nonetheless important considerations. © RSNA, 2016.
Thermo-mechanical process for treatment of welds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malik, R K
1980-03-01
Benefits from thermo-mechanical processing (TMP) of austenitic stainless steel weldments, analogous to hot isostatic pressing (HIP) of castings, most likely result from compressive plastic deformation, enhanced diffusion, and/or increased dislocation density. TMP improves ultrasonic inspectability of austenitic stainless steel welds owing to: conversion of cast dendrites into equiaxed austenitic grains, reduction in size and number of stringers and inclusions, and reduction of delta ferrite content. TMP induces structural homogenization and healing of void-type defects and thus contributes to an increase in elongation, impact strength, and fracture toughness as well as a significant reduction in data scatter for these properties. Anmore » optimum temperature for TMP or HIP of welds is one which causes negligible grain growth and an acceptable reduction in yield strength, and permits healing of porosity.« less
Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component.
John, Thomas K; Ghosh, Gaurav; Ranawat, Chitranjan S; Ranawat, Amar S; Meftah, Morteza
2015-12-01
The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5-9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1. There was no interference demarcation in any zones. Two cups were revised (0.9%): one for dislocation and another for infection. The Kaplan-Meier survivorship for cup revision for any failure (infection, dislocation) was 99% and for mechanical failure (osteolysis, loosening) was 100%. This design has excellent safety, efficacy and durability. Copyright © 2015 Elsevier Inc. All rights reserved.
Effects of hydroxyapatite coating of cups used in hip revision arthroplasty
2012-01-01
Background and purpose Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. Methods We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip Arthroplasty Register (SHAR). 2 such cup designs were identified: Harris-Galante and Trilogy, both available either with or without HA coating. These cups had been used as revision components in 1,780 revisions of total hip arthroplasties (THA) between 1986 and 2009. A Cox proportional hazards model including the type of coating, age at index revision, sex, cause of cup revision, cup design, the use of bone graft at the revision procedure, and the type of cup fixation at primary THA were used to calculate adjusted risk ratios (RRs with 95% CI) for re-revision for any reason or due to aseptic loosening. Results 71% of the cups were coated with HA and 29% were uncoated. At a mean follow-up time of 6.9 (0–24) years, 159 (9%) of all 1,780 cups had been re-revised, mostly due to aseptic loosening (5%), dislocation (2%), or deep infection (1%). HA coating had no significant influence on the risk of re-revision of the cup for any reason (RR = 1.4, CI: 0.9–2.0) or due to aseptic loosening (RR = 1.1, 0.6–1.9). In contrast, HA coating was found to be a risk factor for isolated liner re-revision for any reason (RR = 1.8, CI: 1.01–3.3). Age below 60 years at the index cup revision, dislocation as the cause of the index cup revision, uncemented cup fixation at primary THA, and use of the Harris-Galante cup also increased the risk of re-revision of the cup. In separate analyses in which isolated liner revisions were excluded, bone grafting was found to be a risk factor for re-revision of the metal shell due to aseptic loosening (RR = 2.1, CI: 1.05–4.2). Interpretation We found no evidence to support the notion that HA coating improves the performance of the 2 studied cup designs in revision arthroplasty. In contrast, patient-related factors such as younger age and dislocation as the reason for cup revision, and technical factors such as the choice of revision cup were found to influence the risk of subsequent re-revision of the cup. The reason for inferior results after revision of uncemented cups is not known, but it is possible that these hips more often had pronounced bone loss at the index cup revision. PMID:22937978
Reduction of metallosis in hip implant using thin film coating
NASA Astrophysics Data System (ADS)
Rajeshshyam, R.; Chockalingam, K.; Gayathri, V.; Prakash, T.
2018-04-01
Hip implant finds its emerging attraction due to it continuous demand over the years. The hip implants (femoral head) and acetabulum cup) mainly fabricated by metals such as stainless steel, cobalt chrome and titanium alloys, other than that ceramics and polyethylene have been used. The metal-on-metal hip implant was found to be best implant material for most of the surgeons due to its high surface finish, low wear rate and low chance of dislocation from its position after implanting. Where in metal based hip implant shows less wear rate of 0.01mm3/year. Metal-on-metal implant finds its advantage over other materials both in its mechanical and physical stability against human load. In M-O-M Cobalt- chromium alloys induce metal allergy. The metal allergy (particulate debris) that is generated by wear, fretting, fragmentation and which is unavoidable when a prosthesis is implanted, can induce an inflammatory reaction in some circumstances. The objectives of this research to evaluate thin film coating with Nano particle additives to reduce the wear leads to regarding metal ion release. Experimental results reveals that thin film Sol-Gel coating with 4wt. % of specimen reduced the cobalt and chromium ion release and reduces the wear rate. Wear rate reduced by 98% for 4wt. % graphene in 20N and 95% for 4wt. % graphene in 10N.
Rutenberg, Tal Frenkel; Warshevski, Yaniv; Gold, Aviram; Shasha, Nadav; Snir, Nimrod; Chechik, Ofir; Dolkart, Oleg; Eilig, Dynai; Herman, Amir; Rath, Ehud; Kramer, Moti; Drexler, Michael
2018-05-08
The Mayo metaphysical conservative femoral stem (Zimmer, Warsaw, Indiana) is a wedge-shaped implant designed to transfer loads proximally, reduce femoral destruction, and enable the preservation of bone stock in the proximal femur. Thus, it is a potentially preferred prosthesis for active, non-elderly patients who may require additional future surgeries. This retrospective case study analyzed the outcomes of consecutive patients who underwent total hip replacements with this stem between May 2001 and February 2013. All patients underwent clinical assessment, radiological evaluation for the presence and development of radiolucent lines, and functional assessment (numerical analog scale, Harris hip score, and Short Form-12 questionnaire). Ninety-five hips (79 patients) were available for analysis. The patients' mean age was 43 years (range, 18-64 years), and the mean follow-up was 97 months (range, 26.9-166 months). The postoperative clinical assessments and functional assessments revealed significant improvements. Sixteen patients (20.3%) had 18 orthopedic complications, the most common of which were an intraoperative femoral fracture and implant dislocation requiring revision surgeries in 10 hips (10.5%). Radiological analysis revealed evidence of femoral remodeling in 64 (67.4%) implants, spot welds (neocortex) in 35 (36.8%), and osteolysis in 3 (3.2%). These results suggest that the conservative hip femoral implant has an unacceptable complication rate for non-elderly patients. [Orthopedics. 201x; xx(x):xx-xx.]. Copyright 2018, SLACK Incorporated.
Gromov, Kirill; Troelsen, Anders; Otte, Kristian Stahl; Ørsnes, Thue; Ladelund, Steen; Husted, Henrik
2015-01-01
Patient education and mobilization restrictions are often used in an attempt to reduce the risk of dislocation following primary THA. To date, there have been no studies investigating the safety of removal of mobilization restrictions following THA performed using a posterolateral approach. In this retrospective non-inferiority study, we investigated the rate of early dislocation following primary THA in an unselected patient cohort before and after removal of postoperative mobilization restrictions. From the Danish National Health Registry, we identified patients with early dislocation in 2 consecutive and unselected cohorts of patients who received primary THA at our institution from 2004 through 2008 (n = 946) and from 2010 through 2014 (n = 1,329). Patients in the first cohort were mobilized with functional restrictions following primary THA whereas patients in the second cohort were allowed unrestricted mobilization. Risk of early dislocation (within 90 days) was compared in the 2 groups and odds ratio (OR)-adjusted for possible confounders-was calculated. Reasons for early dislocation in the 2 groups were identified. When we adjusted for potential confounders, we found no increased risk of early dislocation within 90 days in patients who were mobilized without restrictions. Risk of dislocation within 90 days was lower (3.4% vs 2.8%), risk of dislocation within 30 days was lower (2.1% vs 2.0%), and risk of multiple dislocations (1.8% vs 1.1%) was lower in patients who were mobilized without restrictions, but not statistically significantly so. Increasing age was an independent risk factor for dislocation. Removal of mobilization restrictions from the mobilization protocol following primary THA performed with a posterolateral approach did not lead to an increased risk of dislocation within 90 days.
[Tumor prostheses : Important in modern revision arthroplasty].
Hillmann, A; Ipach, I
2015-05-01
Due to demographic aging, an increasing number of revision arthroplasty procedures is expected during upcoming years. While the use of a megaprosthesis for bone reconstruction after tumor resection is gold standard, this type of prosthesis still meets with reservation in the field of revision arthroplasty because of numerous risk factors. The purpose of this article is to present the importance of modular megaprostheses in revision arthroplasty, taking into consideration the risks of periprosthetic infection, aseptic loosening, material failure, and hip dislocation. Because of improvements in the field of megaprostheses during the last 30 years, the risks after implantation of this type of prosthesis have significantly decreased. The risk of periprosthetic infection has been reduced about 1/3 by the use of silver surface coating. Improvements in stem design, cement technique, and the additional use of locking screws have minimized the risk of aseptic loosening. Improvements in material composition have reduced the risk of material failure. The risk of hip dislocation could also be minimized by careful tissue preparation and appropriate suture technique. There is no need for the conservative use of megaprostheses in revision arthroplasty. There are many benefits in the use of megaprostheses in multimorbid patients (i.e., reduced operating time, the possibility of early full weight bearing, and a reduced risk of periprosthetic infection by the use of silver surface coating) instead of complex bone reconstruction during revision arthroplasty.
[The Use of Jumbo Cups in Revision Total Hip Arthroplasty].
von Roth, Philipp; Wassilew, Georgi I
2017-10-01
Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.
The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.
Murphy, William S; Yun, Ho Hyun; Hayden, Brett; Kowal, Jens H; Murphy, Stephen B
2018-02-01
Cup malposition is a common cause of impingement, limitation of ROM, acceleration of bearing wear, liner fracture, and instability in THA. Previous studies of the safe zone based on plain radiographs have limitations inherent to measuring angles from two-dimensional projections. The current study uses CT to measure component position in stable and unstable hips to assess the presence of a safe zone for cup position in THA. (1) Does acetabular component orientation, when measured on CT, differ in stable components and those revised for recurrent instability? (2) Do CT data support historic safe zone definitions for component orientation in THA? We identified 34 hips that had undergone revision of the acetabulum for recurrent instability that also had a CT scan of the pelvis between August 2003 and February 2017. We also identified 175 patients with stable hip replacements who also had a CT study for preoperative planning and intraoperative navigation of the contralateral side. For each CT study, one observer analyzed major factors including acetabular orientation, femoral anteversion, combined anteversion (the sum of femoral and anatomic anteversion), pelvic tilt, total offset difference, head diameter, age, sex, and body mass index. These measures were then compared among stable hips, hips with cup revision for anterior instability, and hips with cup revision for posterior instability. We used a clinically relevant measurement of operative anteversion and inclination as opposed to the historic use of radiographic anteversion and inclination. The percentage of unstable hips in the historic Lewinnek safe zone was calculated, and a new safe zone was proposed based on an area with no unstable hips. Anteriorly unstable hips compared with stable hips had higher operative anteversion of the cup (44° ± 12° versus 31° ± 11°, respectively; mean difference, 13°; 95% confidence interval [CI], 5°-21°; p = 0.003), tilt-adjusted operative anteversion of the cup (40° ± 6° versus 26° ± 10°, respectively; mean difference, 14°; 95% CI, 10°-18°; p < 0.001), and combined tilt-adjusted anteversion of the cup (64° ± 10° versus 54° ± 19°, respectively; mean difference, 10°; 95% CI, 1°-19°; p = 0.028). Posteriorly unstable hips compared with stable hips had lower operative anteversion of the cup (19° ± 15° versus 31° ± 11°, respectively; mean difference, -12°; 95% CI, -5° to -18°; p = 0.001), tilt-adjusted operative anteversion of the cup (19° ± 13° versus 26° ± 10°, respectively; mean difference, -8°; 95% CI, -14° to -2°; p = 0.014), pelvic tilt (0° ± 6° versus 4° ± 6°, respectively; mean difference, -4°; 95% CI, -7° to -1°; p = 0.007), and anatomic cup anteversion (25° ± 18° versus 34° ± 12°, respectively; mean difference, -9°; 95% CI, -1° to -17°; p = 0.033). Thirty-two percent of the unstable hips were located in the Lewinnek safe zone (11 of 34; 10 posterior dislocations, one anterior dislocation). In addition, a safe zone with no unstable hips was identified within 43° ± 12° of operative inclination and 31° ± 8° of tilt-adjusted operative anteversion. The current study supports the notion of a safe zone for acetabular component orientation based on CT. However, the results demonstrate that the historic Lewinnek safe zone is not a reliable predictor of future stability. Analysis of tilt-adjusted operative anteversion and operative inclination demonstrates a new safe zone where no hips were revised for recurrent instability that is narrower for tilt-adjusted operative anteversion than for operative inclination. Tilt-adjusted operative anteversion is significantly different between stable and unstable hips, and surgeons should therefore prioritize assessment of preoperative pelvic tilt and accurate placement in operative anteversion. With improvements in patient-specific cup orientation goals and acetabular component placement, further refinement of a safe zone with CT data may reduce the incidence of cup malposition and its associated complications. Level III, diagnostic study.
Rosenlund, Signe; Broeng, Leif; Overgaard, Søren; Jensen, Carsten; Holsgaard-Larsen, Anders
2016-11-01
The lateral and the posterior approach are the most commonly used procedures for total hip arthroplasty. Due to the detachment of the hip abductors, lateral approach is claimed to cause reduced hip muscle strength and altered gait pattern. However, this has not been investigated in a randomised controlled trial. The aim was to compare the efficacy of total hip arthroplasty performed by lateral or posterior approach on gait function and hip muscle strength up to 12months post-operatively. We hypothesised that posterior approach would be superior to lateral approach. Forty-seven patients with primary hip osteoarthritis were randomised to total hip arthroplasty with either posterior or lateral approach and evaluated pre-operatively, 3 and 12months post-operatively using 3-dimensional gait analyses as objective measures of gait function, including Gait Deviation Index, temporo-spatial parameters and range of motion. Isometric maximal hip muscle strength in abduction, flexion and extension was also tested. Post-operatively, no between-group difference in gait function was observed. However, both hip abductor and flexor muscle strength improved more in the posterior approach group: -0.20(Nm/kg)[95%CI:-0.4 to 0.0] and -0.20(Nm/kg)[95%CI:-0.4 to 0.0], respectively. Contrary to our first hypothesis, the overall gait function in the posterior approach group did not improve more than in the lateral approach group. However, in agreement with our second hypothesis, patients in the posterior approach group improved more in hip abductor and flexor muscle strength at 12months. Further investigation of the effect of reduced maximal hip muscle strength on functional capacity is needed. ClinicalTrials.gov. No.: NCT01616667. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Xin; Lu, Hongbing; Chen, Hanyong; Zhao, Li; Shi, Zhengxing; Liang, Zhengrong
2009-02-01
Developmental dysplasia of the hip is a congenital hip joint malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Conventionally, physicians made diagnoses and treatments only based on findings from two-dimensional (2D) images by manually calculating clinic parameters. However, anatomical complexity of the disease and the limitation of current standard procedures make accurate diagnosis quite difficultly. In this study, we developed a system that provides quantitative measurement of 3D clinical indexes based on computed tomography (CT) images. To extract bone structure from surrounding tissues more accurately, the system firstly segments the bone using a knowledge-based fuzzy clustering method, which is formulated by modifying the objective function of the standard fuzzy c-means algorithm with additive adaptation penalty. The second part of the system calculates automatically the clinical indexes, which are extended from 2D to 3D for accurate description of spatial relationship between femurs and acetabulum. To evaluate the system performance, experimental study based on 22 patients with unilateral or bilateral affected hip was performed. The results of 3D acetabulum index (AI) automatically provided by the system were validated by comparison with 2D results measured by surgeons manually. The correlation between the two results was found to be 0.622 (p<0.01).
de Thomasson, E; Guingand, O; Terracher, R; Mazel, C
2001-09-01
We conducted a retrospective study to assess morbidity and mortality in patients undergoing revision total hip arthroplasty (THA) procedures. Perioperative complications were recorded in 181 revision procedures (162 patients) performed between January 1995 and March 1999 (117 bipolar revisions and 64 acetabular isolated revisions). There were 86 complications (68 patients) leading to 21 new revisions. About half (50/86) were related to the surgical procedure (dislocation, femoral fracture, infection.). Life-threatening complications (3.6%) ended in patient death in 1.6% of the cases. Complications were more frequent in patients with an ASA score=3 (p<0.01) or aged over 75 years (p<0.05). Age was also predictive of femoral misalignment and fracture (p<0.05). Dislocations (8.8%) were observed more frequently in patients who had undergone more than 2 procedures prior to the revision (p<0.05) (4.8% of the dislocations in patients undergoing a first revision procedure and 14.3% in the others). In addition, peroperative blood loss and duration of the procedure were significantly greater in case of bipolar replacement than for isolated acetabular replacement (sigma > 1.96). Our experience and data in the literature point to the important age factor in the development of complications. Preservation of a well-fixed femoral component does not appear to worsen prognosis and leads to fewer complications than bipolar changes. The decision to revise a THA must take into consideration the functional impairment but also the risks inherent in revision procedures, particularly in old patients who have undergone several procedures. Revising the acetabular component alone can be an interesting option if the femoral component remains well-fixed although our follow-up is insufficient to determine whether this attitude provides better long-term outcome than complete biopolar revision. Better patient selection and improved operative technique, in particular in femur preparation, should help reduce morbidity and mortality in this type of procedure.
NASA Astrophysics Data System (ADS)
Gornostyrev, Yu. N.
2005-03-01
The plastic deformation in bcc metals is realized by the motion of screw dislocations with a complex star-like non-planar core. In this case, the direct investigation of the solute effect by first principles electronic structure calculations is a challenging problem for which we follow a combined approach that includes atomistic dislocation modelling with ab-initio parametrization of interatomic interactions. The screw dislocation core structure in Mo alloys is described within the model of atomic row displacements along a dislocation line with the interatomic row potential estimated from total energy full-potential linear muffin-tin orbital (FLMTO) calculations with the generalized gradient approximation (GGA) for the exchange-correlation potential. We demonstrate (1) that the solute effect on the dislocation structure is different for ``hard'' and ``easy'' cores and (2) that the softener addition in a ``hard'' core gives rise to a structural transformation into a configuration with a lower energy through an intermediate state. The softener solute is shown to disturb locally the three-fold symmetry of the dislocation core and the dislocation structure tends to the split planar core.
Wacha, H; Domsel, G; Herrmann, E
2018-06-01
An arthroplasty registry in Germany has been recently established but long-term results for most short-stem innovations are missing. Short-stem hip arthroplasty is usually indicated in young active patients. Our indication was extended to older age groups, femoral neck fractures (FNF), and dysplasia. We evaluated all total hip arthroplasties (THAs) in this population with a collum femoris preserving stem (CFP) performed from 2003 to 2013. A consecutive cohort of 1217 CFP THAs with a mean age of 68.7 years was followed retrospectively for a median of 4.8 years (patient follow-up interquartile range from 3.0 to 6.9 years). A questionnaire, which we used in two previous studies, was answered by 89.15% of patients and included information regarding complaints, grade of satisfaction, re-operations, and dislocation. Of the 1217 patients, 77 had died. Survival of the stem and the cup was assessed using a competing risks approach according to an Aalen-Johanson estimator with revision for septic or aseptic loosening or death as a competing endpoint. Of the patients who answered the questionnaire, 92.5% had no complaints related to the procedures. In all 1217 patients, there were 43 revisions (4.2%) as follows: stem and cup revisions due to aseptic loosening of the stem (n = 10), infections (n = 6), pain (n = 4), or trauma (n = 3); cup revisions due to aseptic loosening (n = 3), dislocation (n = 5), and offset revisions (n = 12). Survivorship was 96% for the stem and 99% for the cup 9 years postoperatively. Statistical analysis confirmed a higher risk for revision in patients with a younger age (p = 0.033), male sex (p = 0.040), dysplasia (p = 0.032), and undersized or extra-large stems for stem revisions (p = 0.001) and female sex (p = 0.036) for cup revisions. FNF (p > 0.20) and age ≥ 80 years (p = 0.114) had no higher risk for loosening of the stem. Our data is also compared with the current literature, especially with the available CFP studies. The survival rate of the CFP stem was as high as 96% after 9 years of followup which compares well-to-previously published long-term survival rates. There is no higher risk for revision in patients 80 years old or older and in cases with femoral neck fractures. The CFP preserves also allowed using standard stems in the rare cases of revision.
NASA Astrophysics Data System (ADS)
Bertin, N.; Upadhyay, M. V.; Pradalier, C.; Capolungo, L.
2015-09-01
In this paper, we propose a novel full-field approach based on the fast Fourier transform (FFT) technique to compute mechanical fields in periodic discrete dislocation dynamics (DDD) simulations for anisotropic materials: the DDD-FFT approach. By coupling the FFT-based approach to the discrete continuous model, the present approach benefits from the high computational efficiency of the FFT algorithm, while allowing for a discrete representation of dislocation lines. It is demonstrated that the computational time associated with the new DDD-FFT approach is significantly lower than that of current DDD approaches when large number of dislocation segments are involved for isotropic and anisotropic elasticity, respectively. Furthermore, for fine Fourier grids, the treatment of anisotropic elasticity comes at a similar computational cost to that of isotropic simulation. Thus, the proposed approach paves the way towards achieving scale transition from DDD to mesoscale plasticity, especially due to the method’s ability to incorporate inhomogeneous elasticity.
Sex and growth effect on pediatric hip injuries presenting to sports medicine clinic.
Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A; Lewis, Cara L; Sugimoto, Dai
2016-07-01
To compare sports-related hip injuries on the basis of sex and age in a cohort of young athletes. A 5% random probability sample of all new patients' charts over a 10-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic vs. overuse), and types (bony vs. soft tissue) were compared by sex and age (preadolescent vs. adolescent). Descriptive and χ-analyses were carried out. The interaction of sex and age with respect to hip injury over time was examined by two-way (sex, age) analysis of variance. A total of 2133 charts were reviewed; N=87 hip injuries. The main diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%), and tendonitis (7.7%). The main diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%), and bursitis (4.9%). The five most common sports/activities at the time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and field (6.9%). Age by sex comparisons showed a greater proportion of the total hip injuries (38.5%) in males compared with females (8.2%) during preadolescence (5-12 years). However, in adolescence (13-17 years), the hip injury proportion was significantly higher in females (91.8%) compared with males (61.5%; P<0.001). Injury mechanism and type differed by sex, with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%) compared with males (50.0 and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progressed through puberty compared with males (analysis of variance sex-by-age interaction; P<0.001). Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age compared with males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, require further investigation to facilitate efforts aimed at prevention. Cross-sectional epidemiological study.
Sex and Growth Effect on Pediatric Hip Injuries Presenting to Sports Medicine Clinic
Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A.; Lewis, Cara L.; Sugimoto, Dai
2016-01-01
Background To compare sports-related hip injuries based on sex and age in a cohort of young athletes. Methods 5% random probability sample of all new patients’ charts over a ten-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic versus overuse), and types (bony versus soft tissue) were compared by sex and age (pre-adolescent versus adolescent). Descriptive and chi-square analyzes were performed. The interaction of sex and age with regard to hip injury over time was examined by a two-way (sex, age) analysis of variance (ANOVA). Results 2,133 charts were reviewed; N=87 hip injuries. Leading diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%) and tendonitis (7.7%). Leading diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%) and bursitis (4.9%). Five most common sports/activities at time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and fields (6.9%). Growth/maturation by sex showed a greater proportion of the total hip injuries (38.5%) compared to females (8.2%) during pre-adolescence (5-12 years). However, in adolescence (13-17 years), hip injury proportion was significantly greater in females (91.8%), as compared to males (61.5%; P<0.001). Injury mechanism and type differed by sex with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%), as compared to males (50.0% and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progress through puberty as compared to males (ANOVA sex-by-age interaction; P<0.001). Conclusions Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age as compared to males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, requires further investigation in order to facilitate efforts aimed at prevention. PMID:27058819
Upwardly Mobile Working-Class Adolescents: A Biographical Approach on Habitus Dislocation
ERIC Educational Resources Information Center
Christodoulou, Michael; Spyridakis, Manos
2017-01-01
Habitus dislocation is a much debatable term. By presenting life-histories of working-class adolescents, this article argues (i) that not all upwardly mobile working-class adolescents experience habitus dislocation and, (ii) that habitus dislocation has its roots in the self-initiated ruptures that face some of those who want to be upwardly mobile…
A discrete mechanics approach to dislocation dynamics in BCC crystals
NASA Astrophysics Data System (ADS)
Ramasubramaniam, A.; Ariza, M. P.; Ortiz, M.
2007-03-01
A discrete mechanics approach to modeling the dynamics of dislocations in BCC single crystals is presented. Ideas are borrowed from discrete differential calculus and algebraic topology and suitably adapted to crystal lattices. In particular, the extension of a crystal lattice to a CW complex allows for convenient manipulation of forms and fields defined over the crystal. Dislocations are treated within the theory as energy-minimizing structures that lead to locally lattice-invariant but globally incompatible eigendeformations. The discrete nature of the theory eliminates the need for regularization of the core singularity and inherently allows for dislocation reactions and complicated topological transitions. The quantization of slip to integer multiples of the Burgers' vector leads to a large integer optimization problem. A novel approach to solving this NP-hard problem based on considerations of metastability is proposed. A numerical example that applies the method to study the emanation of dislocation loops from a point source of dilatation in a large BCC crystal is presented. The structure and energetics of BCC screw dislocation cores, as obtained via the present formulation, are also considered and shown to be in good agreement with available atomistic studies. The method thus provides a realistic avenue for mesoscale simulations of dislocation based crystal plasticity with fully atomistic resolution.
Jacobs, Jeremy M.; Evanson, J. Richard; Pniewski, Josh; Dickston, Michelle L.; Mueller, Terry; Bojescul, John A.
2017-01-01
Introduction Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. Purpose The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Methods Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Results Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants’ functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Conclusions Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level of Evidence Level 4, Case-series PMID:29181261
Shaw, K Aaron; Jacobs, Jeremy M; Evanson, J Richard; Pniewski, Josh; Dickston, Michelle L; Mueller, Terry; Bojescul, John A
2017-10-01
Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants' functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level 4, Case-series.
Statistics of dislocation pinning at localized obstacles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutta, A.; Bhattacharya, M., E-mail: mishreyee@vecc.gov.in; Barat, P.
2014-10-14
Pinning of dislocations at nanosized obstacles like precipitates, voids, and bubbles is a crucial mechanism in the context of phenomena like hardening and creep. The interaction between such an obstacle and a dislocation is often studied at fundamental level by means of analytical tools, atomistic simulations, and finite element methods. Nevertheless, the information extracted from such studies cannot be utilized to its maximum extent on account of insufficient information about the underlying statistics of this process comprising a large number of dislocations and obstacles in a system. Here, we propose a new statistical approach, where the statistics of pinning ofmore » dislocations by idealized spherical obstacles is explored by taking into account the generalized size-distribution of the obstacles along with the dislocation density within a three-dimensional framework. Starting with a minimal set of material parameters, the framework employs the method of geometrical statistics with a few simple assumptions compatible with the real physical scenario. The application of this approach, in combination with the knowledge of fundamental dislocation-obstacle interactions, has successfully been demonstrated for dislocation pinning at nanovoids in neutron irradiated type 316-stainless steel in regard to the non-conservative motion of dislocations. An interesting phenomenon of transition from rare pinning to multiple pinning regimes with increasing irradiation temperature is revealed.« less
Luscher, Darby Jon; Mayeur, Jason Rhea; Mourad, Hashem Mohamed; ...
2015-08-05
Here, we have developed a multi-physics modeling approach that couples continuum dislocation transport, nonlinear thermoelasticity, crystal plasticity, and consistent internal stress and deformation fields to simulate the single-crystal response of materials under extreme dynamic conditions. Dislocation transport is modeled by enforcing dislocation conservation at a slip-system level through the solution of advection-diffusion equations. Nonlinear thermoelasticity provides a thermodynamically consistent equation of state to relate stress (including pressure), temperature, energy densities, and dissipation. Crystal plasticity is coupled to dislocation transport via Orowan's expression where the constitutive description makes use of recent advances in dislocation velocity theories applicable under extreme loading conditions.more » The configuration of geometrically necessary dislocation density gives rise to an internal stress field that can either inhibit or accentuate the flow of dislocations. An internal strain field associated with the internal stress field contributes to the kinematic decomposition of the overall deformation. The paper describes each theoretical component of the framework, key aspects of the constitutive theory, and some details of a one-dimensional implementation. Results from single-crystal copper plate impact simulations are discussed in order to highlight the role of dislocation transport and pile-up in shock loading regimes. The main conclusions of the paper reinforce the utility of the modeling approach to shock problems.« less
Serum Metal Ion Levels Following Total Hip Arthroplasty With Modular Dual Mobility Components.
Matsen Ko, Laura J; Pollag, Kimberley E; Yoo, Joanne Y; Sharkey, Peter F
2016-01-01
Dual mobility acetabular components can reduce the incidence of total hip arthroplasty (THA) instability. Modular dual mobility (MDM) components facilitate acetabular component implantation. However, corrosion can occur at modular junctions. Serum cobalt and chromium levels and Oxford scores were obtained at minimum two year follow-up for 100 consecutive patients who had THA with MDM components. Average Oxford score was 43 (range 13-48). Average serum cobalt and chromium values were 0.7 mcg/L (range, 0.0 to 7.0) and 0.6 mcg/L (range, 0.1 to 2.7), respectively. MARS MRI was performed for four patients with pain and elevated serum cobalt levels. Two of these studies were consistent with adverse local tissue reaction. We recommend use of MDM implants in only patients at high risk for dislocation following THA. Copyright © 2016 Elsevier Inc. All rights reserved.
A numerical spectral approach to solve the dislocation density transport equation
NASA Astrophysics Data System (ADS)
Djaka, K. S.; Taupin, V.; Berbenni, S.; Fressengeas, C.
2015-09-01
A numerical spectral approach is developed to solve in a fast, stable and accurate fashion, the quasi-linear hyperbolic transport equation governing the spatio-temporal evolution of the dislocation density tensor in the mechanics of dislocation fields. The approach relies on using the Fast Fourier Transform algorithm. Low-pass spectral filters are employed to control both the high frequency Gibbs oscillations inherent to the Fourier method and the fast-growing numerical instabilities resulting from the hyperbolic nature of the transport equation. The numerical scheme is validated by comparison with an exact solution in the 1D case corresponding to dislocation dipole annihilation. The expansion and annihilation of dislocation loops in 2D and 3D settings are also produced and compared with finite element approximations. The spectral solutions are shown to be stable, more accurate for low Courant numbers and much less computation time-consuming than the finite element technique based on an explicit Galerkin-least squares scheme.
Wenger, Daniel; Samuelsson, Hanna; Düppe, Henrik; Tiderius, Carl Johan
2016-01-01
Background and purpose — Avascular necrosis of the femoral head (AVN) is a complication in treatment of developmental dysplasia of the hip (DDH). We evaluated the risk of AVN after early treatment in the von Rosen splint and measured the diameter of the ossific nucleus at 1 year of age. Children and methods — All children born in Malmö, Sweden, undergo clinical screening for neonatal instability of the hip (NIH). We reviewed 1-year radiographs of all children treated early for NIH in our department from 2003 through 2010. The diameter of the ossific nucleus was measured, and signs of AVN were classified according to Kalamchi-MacEwen. Subsequent radiographs, taken for any reason, were reviewed and a local registry of diagnoses was used to identify subsequent AVN. Results — 229 of 586 children referred because of suspected NIH received early treatment (age ≤ 1 week) for NIH during the study period. 2 of the 229 treated children (0.9%, 95% CI: 0.1–3.1) had grade-1 AVN. Both had spontaneous resolution and were asymptomatic during the observation time (6 and 8 years). 466 children met the inclusion criteria for measurement of the ossific nucleus. Neonatally dislocated hips had significantly smaller ossific nuclei than neonatally stable hips: mean 9.4 mm (95% CI: 9.1–9.8) vs. 11.1 mm (95% CI: 10.9–11.3) at 1 year (p < 0.001). Interpretation — Early treatment with the von Rosen splint for NIH is safe regarding AVN. The ossification of the femoral head is slower in children with NIH than in untreated children with neonatally stable hips. PMID:26730503
Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.
Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D
2015-04-01
The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.
Effect of Body Mass Index on Complications and Reoperations After Total Hip Arthroplasty.
Wagner, Eric R; Kamath, Atul F; Fruth, Kristin M; Harmsen, William S; Berry, Daniel J
2016-02-03
High body mass index (BMI) is associated with increased rates of complications after total hip arthroplasty. Studies to date have evaluated risk mainly as a dichotomous variable according to BMI thresholds. The purpose of this paper was to characterize the risk of complications and implant survival according to BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 21,361 consecutive hips (17,774 patients) treated with primary total hip arthroplasty between 1985 and 2012 at a single institution. The average BMI at the time of surgery was 28.7 kg/m(2) (range, 15 to 69 kg/m(2)). Estimates of revision surgery and common complications associated with BMI were analyzed using the Kaplan-Meier method of assessing survivorship, with associations of outcomes assessed using a Cox model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p = 0.002) increased with increasing BMI. Increasing BMI was associated with increased rates of early hip dislocation (p = 0.02), wound infection, and, most strikingly, deep periprosthetic infection (a hazard ratio of 1.09 per unit of BMI >25 kg/m(2); p < 0.001). However, we found no association between increasing BMI and any revision for mechanical failure of the implant or between increasing BMI and revision for aseptic implant loosening. There was an inverse correlation between increasing BMI and risk of revision for bearing wear. The rates of reoperation, implant revision or removal, and common complications after total hip arthroplasty were strongly associated with BMI. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Tuberculosis of the hip in children: A retrospective analysis of 27 patients.
Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas
2014-09-01
We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial "triradiate" and normal types and worst with posttreatment atrophic and "ankylosed" types. The Shanmugasundaram radiological types accurately predict prognosis only in normal types and "triradiate" pattern. The functional outcome is independent of radiological morphology of the hip in smaller children.
Tuberculosis of the hip in children: A retrospective analysis of 27 patients
Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas
2014-01-01
Background: We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. Materials and Methods: We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. Results: The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial “triradiate” and normal types and worst with posttreatment atrophic and “ankylosed” types. Conclusions: The Shanmugasundaram radiological types accurately predict prognosis only in normal types and “triradiate” pattern. The functional outcome is independent of radiological morphology of the hip in smaller children. PMID:25298552
Debye screening of dislocations.
Groma, I; Györgyi, G; Kocsis, B
2006-04-28
Debye-like screening by edge dislocations of some externally given stress is studied by means of a variational approach to coarse grained field theory. Explicitly given are the force field and the induced geometrically necessary dislocation (GND) distribution, in the special case of a single glide axis in 2D, for (i) a single edge dislocation and (ii) a dislocation wall. Numerical simulation demonstrates that the correlation in relaxed dislocation configurations is in good agreement with the induced GND in case (i). Furthermore, the result (ii) well predicts the experimentally observed decay length for the GND developing close to grain boundaries.
Modal analysis of dislocation vibration and reaction attempt frequency
Sobie, Cameron; Capolungo, Laurent; McDowell, David L.; ...
2017-02-04
Transition state theory is a fundamental approach for temporal coarse-graining. It estimates the reaction rate for a transition processes by quantifying the activation free energy and attempt frequency for the unit process. To calculate the transition rate of a gliding dislocation, the attempt frequency is often obtained from line tension estimates of dislocation vibrations, a highly simplified model of dislocation behavior. This work revisits the calculation of attempt frequency for a dislocation bypassing an obstacle, in this case a self-interstitial atom (SIA) loop. First, a direct calculation of the vibrational characteristics of a finite pinned dislocation segment is compared tomore » line tension estimates before moving to the more complex case of dislocation-obstacle bypass. The entropic factor associated with the attempt frequency is calculated for a finite dislocation segment and for an infinite glide dislocation interacting with an SIA loop. Lastly, it is found to be dislocation length independent for three cases of dislocation-self interstitial atom (SIA) loop interactions.« less
Dynamics of threading dislocations in porous heteroepitaxial GaN films
NASA Astrophysics Data System (ADS)
Gutkin, M. Yu.; Rzhavtsev, E. A.
2017-12-01
Behavior of threading dislocations in porous heteroepitaxial gallium nitride (GaN) films has been studied using computer simulation by the two-dimensional discrete dislocation dynamics approach. A computational scheme, where pores are modeled as cross sections of cylindrical cavities, elastically interacting with unidirectional parallel edge dislocations, which imitate threading dislocations, is used. Time dependences of coordinates and velocities of each dislocation from dislocation ensembles under investigation are obtained. Visualization of current structure of dislocation ensemble is performed in the form of a location map of dislocations at any time. It has been shown that the density of appearing dislocation structures significantly depends on the ratio of area of a pore cross section to area of the simulation region. In particular, increasing the portion of pores surface on the layer surface up to 2% should lead to about a 1.5-times decrease of the final density of threading dislocations, and increase of this portion up to 15% should lead to approximately a 4.5-times decrease of it.
Harnessing atomistic simulations to predict the rate at which dislocations overcome obstacles
NASA Astrophysics Data System (ADS)
Saroukhani, S.; Nguyen, L. D.; Leung, K. W. K.; Singh, C. V.; Warner, D. H.
2016-05-01
Predicting the rate at which dislocations overcome obstacles is key to understanding the microscopic features that govern the plastic flow of modern alloys. In this spirit, the current manuscript examines the rate at which an edge dislocation overcomes an obstacle in aluminum. Predictions were made using different popular variants of Harmonic Transition State Theory (HTST) and compared to those of direct Molecular Dynamics (MD) simulations. The HTST predictions were found to be grossly inaccurate due to the large entropy barrier associated with the dislocation-obstacle interaction. Considering the importance of finite temperature effects, the utility of the Finite Temperature String (FTS) method was then explored. While this approach was found capable of identifying a prominent reaction tube, it was not capable of computing the free energy profile along the tube. Lastly, the utility of the Transition Interface Sampling (TIS) approach was explored, which does not need a free energy profile and is known to be less reliant on the choice of reaction coordinate. The TIS approach was found capable of accurately predicting the rate, relative to direct MD simulations. This finding was utilized to examine the temperature and load dependence of the dislocation-obstacle interaction in a simple periodic cell configuration. An attractive rate prediction approach combining TST and simple continuum models is identified, and the strain rate sensitivity of individual dislocation obstacle interactions is predicted.
Vijapura, Anita; Levine, Harlan B; Donato, Michele; Hartzband, Mark A; Baker, Melissa; Klein, Gregg R
2018-03-01
The immunosuppressive regimens required for hematopoietic stem cell transplantation predispose recipients to complications, including avascular necrosis. Cancer-related comorbidities, immunosuppression, and poor bone quality theoretically increase the risk for perioperative medical complications, infection, and implant-related complications in total joint arthroplasty. This study reviewed 20 primary total hip arthroplasties for avascular necrosis in 14 patients. Outcomes were assessed at routine clinical visits and Harris hip scores were calculated. Follow-up radiographs were evaluated for component malposition, loosening, polyethylene wear, and osteolysis. Average follow-up was 44.5 months for all patients. Postoperative clinical follow-up revealed good to excellent outcomes, with significant improvement in functional outcome scores. There were no periprosthetic infections or revisions for aseptic loosening. There was 1 dislocation on postoperative day 40, which was treated successfully with a closed reduction. Two patients with a prior history of venous thromboembolism developed a pulmonary embolus on postoperative day 13 and 77, respectively. Four patients died several months to years after arthroplasty of complications unrelated to the surgical procedure. Total hip arthroplasty can both be safely performed and greatly improve quality of life in recipients of hematopoietic stem cell transplantation who develop avascular necrosis. However, prolonged venous thromboembolism prophylaxis should be carefully considered in this high-risk patient population. [Orthopedics. 2018; 41(2):e257-e261.]. Copyright 2018, SLACK Incorporated.
Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan
2014-01-01
The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703
Similar range of motion and function after resurfacing large–head or standard total hip arthroplasty
2013-01-01
Background and purpose Large–size hip articulations may improve range of motion (ROM) and function compared to a 28–mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA) could impair rehabilitation. We investigated the effect of head size and surgical procedure on postoperative rehabilitation in a randomized clinical trial (RCT). Methods We followed randomized groups of RHAs, large–head THAs and standard THAs at 2 months, 6 months, 1 and 2 years postoperatively, recording clinical rehabilitation parameters. Results Large articulations increased the mean total range of motion by 13° during the first 6 postoperative months. The increase was not statistically significant and was transient. The 2–year total ROM (SD) for RHA, standard THA, and large–head THA was 221° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. Interpretation Head size had no influence on range of motion. The lack of restriction allowed for large articulations did not improve the clinical and patient–perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762. PMID:23530872
Anterior fracture dislocation of the sacroiliac joint: A case report and literature review.
Xiao, Jianlin; Wang, Yang; Zhang, Minglei; Jiang, Rui; Zhu, Tongtong; Liu, Guangyao; Zuo, Jianlin
2017-08-09
Publications describing the diagnosis and treatment of anterior dislocation of the sacroiliac joint are scarce. We report the case a 19-year-old female at 8 weeks' gestation who presented with anterior fracture dislocation of the right sacroiliac joint, posterior fracture dislocation of the left sacroiliac joint (crescent fracture), and incomplete abortion resulting from high energy trauma. Orthopedic surgery involved standard anterior sacroiliac joint plating using an ilioinguinal approach combined with a modified Stoppa approach. Three attempts at complete abortion failed. Complete abortion was eventually achieved by dilatation and curettage two weeks after orthopedic surgery. Our findings reveal a need to improve techniques for diagnosis and treatment of anterior fracture dislocation of the sacroiliac joint, so greater attention can be paid to the rapid and effective management of associated comorbidities, and those resulting from the initial trauma.
Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan
2016-06-01
To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly patients, hip joint function in patients aged more than 80 years old is worse, while there was no obvious market effect in fracture classification, whether to use tension band and type of distal fixation prosthesis, moreover, proximal femoral osteolysis should be focused on.
Adventure sports and sexual freedom hip replacement: the tripolar hip.
Pritchett, James W
2018-01-01
Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal sensitivity reactions. The range of motion achieved, sexual, and functional outcomes were higher than with other types of total hip replacement. This ceramic-coated tripolar prosthesis using highly cross-linked polyethylene provides full function, complete stability, and low wear to younger, active patients, thus confirming the hypothesis and clinical relevance.
Does Participation in Sports Affect Osteoarthritic Progression After Periacetabular Osteotomy?
Hara, Daisuke; Hamai, Satoshi; Fukushi, Jun-Ichi; Kawaguchi, Ken-Ichi; Motomura, Goro; Ikemura, Satoshi; Komiyama, Keisuke; Nakashima, Yasuharu
2017-09-01
Periacetabular osteotomy (PAO) is an effective treatment for symptomatic acetabular dysplasia. However, whether postoperative participation in sports leads to progression of the Kellgren-Lawrence (KL) grade of osteoarthritis (OA) in these patients is unclear. To investigate (1) participation in sports before and after PAO and (2) whether postoperative participation in sports leads to progression of the KL grade. Case-control study; Level of evidence, 3. The authors retrospectively reviewed data on 161 patients (183 hips) who underwent PAO for symptomatic acetabular dysplasia with preoperative KL grade 1 or 2 between 1998 and 2011. The mean age at the time of surgery was 42.0 ± 10.9 years (range, 12-64 years), and the mean follow-up duration was 100 months (range, 13-180 months). Data included participation in sports, the University of California, Los Angeles (UCLA) activity scale score, age at the time of surgery, body mass index, follow-up duration, history of treatment for developmental hip dislocations, Merle d'Aubigné-Postel score, Oxford Hip Score, center-edge angle, and KL grade. Univariate and multivariate analyses were applied to determine which factors were associated with progression to KL grade 3 or 4 after PAO. The number of patients who participated in sports significantly increased from 50 (31.1%) preoperatively to 89 (55.3%) postoperatively. The mean UCLA score significantly increased from 4.7 ± 2.1 preoperatively to 5.5 ± 2.0 postoperatively. The KL grade progressed to grade 3 or 4 in 16 hips, including 4 hips that underwent conversion to total hip arthroplasty. No significant differences were found in postoperative participation in sports (89 hips [53.3%] vs 11 hips [68.8%], respectively; P = .24) and the UCLA score (5.6 ± 2.0 vs 5.1 ± 2.0, respectively; P = .30) between hips with KL grade 1 or 2 and KL grade 3 or 4. A multivariate analysis revealed that no factors, including postoperative participation in sports, were significantly associated with progression to KL grade 3 or 4. Postoperative participation in sports after PAO did not significantly and negatively influence progression of the KL grade at midterm follow-up.
[Larsen syndrome: two reports of cases with spinal cord compromise].
Martín Fernández-Mayoralas, D; Fernández-Jaén, A; Muñoz-Jareño, N; Calleja-Pérez, B; San Antonio-Arce, V; Martínez-Boniche, H
Larsen syndrome is characterised by untreatable congenital dislocation of multiple body joints, along with marked foot deformities. These patients have a flattened face with a short nose, a broad depressed nasal bridge and a prominent forehead. In this clinical note our aim is to report two cases that coursed with spinal cord compromise. Case 1: an 18-month-old female with congenital dislocation of knees and hips. The patient had a flat face, sunken root of nose, and carp mouth. Magnetic resonance imaging of the spine showed severe cervical kyphosis secondary to malformation and hypoplasia of the cervical vertebral bodies and important compression of the spinal cord. Clinically, there were also signs of upper motor neuron syndrome, which was especially prominent in the lower limbs. Case 2: a 14-year-old male with a characteristic face and dislocation of the head of the radius. The patient presented amyotrophy of the muscles in the right hand and clinical signs of lower motor neuron syndrome due to neuronal damage secondary to spinal malformations. Larsen syndrome is an infrequent osteochondrodysplasia. Alteration of the spine is common and may give rise to spinal cord compression with varying clinical repercussions which require surgical treatment in the early years of the patient's life.
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty.
Berger, Richard A; Jacobs, Joshua J; Meneghini, R Michael; Della Valle, Craig; Paprosky, Wayne; Rosenberg, Aaron G
2004-12-01
To assess the potential recovery rate of a minimally invasive total hip replacement technique with minimal soft tissue disruption, an accelerated rehabilitation protocol was implemented with weightbearing as tolerated on the day of surgery. One hundred consecutive patients were enrolled in this prospective study. Ninety-seven patients (97%) met all the inpatient physical therapy goals required for discharge to home on the day of surgery; 100% of patients achieved these goals within 23 hours of surgery. Outpatient therapy was initiated in 9% of patients immediately, 62% of patients by 1 week, and all patients by 2 weeks. The mean time to discontinued use of crutches, discontinued use of narcotic pain medications, and resumed driving was 6 days postoperatively. The mean time to return to work was 8 days, discontinued use of any assistive device was 9 days, and resumption of all activities of daily living was 10 days. The mean time to walk (1/2) mile was 16 days. Furthermore, there were no readmissions, no dislocations, and no reoperations. Therefore, a rapid rehabilitation protocol is safe and fulfills the potential benefits of a rapid recovery with minimally invasive total hip arthroplasty.
Dislocation mechanisms in stressed crystals with surface effects
NASA Astrophysics Data System (ADS)
Wu, Chi-Chin; Crone, Joshua; Munday, Lynn; Discrete Dislocation Dynamics Team
2014-03-01
Understanding dislocation properties in stressed crystals is the key for important processes in materials science, including the strengthening of metals and the stress relaxation during the growth of hetero-epitaxial structures. Despite existing experimental approaches and theories, many dislocation mechanisms with surface effects still remain elusive in experiments. Even though discrete dislocation dynamics (DDD) simulations are commonly employed to study dislocations, few demonstrate sufficient computational capabilities for massive dislocations with the combined effects of surfaces and stresses. Utilizing the Army's newly developed FED3 code, a DDD computation code coupled with finite elements, this work presents several dislocation mechanisms near different types of surfaces in finite domains. Our simulation models include dislocations in a bended metallic cantilever beam, near voids in stressed metals, as well as threading and misfit dislocations in as-grown semiconductor epitaxial layers and their quantitative inter-correlations to stress relaxation and surface instability. Our studies provide not only detailed physics of individual dislocation mechanisms, but also important collective dislocation properties such as dislocation densities and strain-stress profiles and their interactions with surfaces.
Bilateral posterior fracture-dislocation of the shoulder: Report of two cases
Claro, Rui; Sousa, Ricardo; Massada, Marta; Ramos, Joaquim; Lourenço, José M.
2009-01-01
Bilateral posterior fracture-dislocation of the shoulder is a very rare injury. Almost 50% of bilateral posterior dislocations are due to a convulsive seizure, rising to 90% if the dislocations are associated with fractures. Electric shock accounts for less than 5% of bilateral posterior dislocations of the shoulder. A systematization of the clinical and radiological approach, followed by an early diagnosis and proper surgical treatment is essential. Authors report 2 cases of bilateral posterior fracture-dislocation of the shoulder, one caused by a convulsive seizure and the other by an electric shock. A review of literature and a treatment protocol are also presented. PMID:20661400
Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.
Raman, R; Kamath, R P; Parikh, A; Angus, P D
2005-08-01
We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.
Effect of solute atoms on dislocation motion in Mg: An electronic structure perspective
Tsuru, T.; Chrzan, D. C.
2015-01-01
Solution strengthening is a well-known approach to tailoring the mechanical properties of structural alloys. Ultimately, the properties of the dislocation/solute interaction are rooted in the electronic structure of the alloy. Accordingly, we compute the electronic structure associated with, and the energy barriers to dislocation cross-slip. The energy barriers so obtained can be used in the development of multiscale models for dislocation mediated plasticity. The computed electronic structure can be used to identify substitutional solutes likely to interact strongly with the dislocation. Using the example of a-type screw dislocations in Mg, we compute accurately the Peierls barrier to prismatic plane slip and argue that Y, Ca, Ti, and Zr should interact strongly with the studied dislocation, and thereby decrease the dislocation slip anisotropy in the alloy. PMID:25740411
Drimal, J
1989-10-01
The authors present in their work the results of the analysis of the relation between congenital dislocation of vertebral joints and social factors which they have found out in 120 children singled out of 9516 live-born children in the Martin district (Slovakia) in the period 1979-1983. The investigation of social factors has been based on the analysis of socioeconomic and social conditions of the Martin district which has no regional particularities. According to their results the share of exogenous factors in the origin and development of this disease is manifested more frequently in the first-borns (having the highest representation in the examined group). On the top of the list of social indices, which they have examined in primiparae and multiparae respectively, there are unsuitable housing conditions (living in discord with mother-in-law in the same house-hold), high percentage of impregnation before marriage which can be considered a strain and longterm conflicting situation and can have together with other factors a sociopathogenetic effect.
Outcomes using wedge stem with full hydroxiapatite coverage with a minimum of 5 years' follow-up.
Godoy-Monzon, D; Buttaro, M; Comba, F; Zanotti, G; Piccaluga, F; Neira-Borrajo, I
Total Hip Arthroplsty (THA) using uncemented stems is a popular practice in the last decades. The implant survivorship is crtitical and a less than 10% revision at 10 years is been propesed for commercialization and use. To analyse the clinicoradiological results of an uncemented hydroxiapatite covered wedge stem with a 5 years minimum follow up. Prospective study, patients aged from 21-75years were included. All patients received an Element stem (Exactech) and uncemented cup with crosslink poly and 32 mm metal head, and posterior approach with piriformis retention was used. Scheduled clinical and radiographic evaluation at 3 weeks, 3-6 month, year and subsequent years using Harris Hip Score and Merle d'Aubigné Postel. Intraoperative and during follow up complications were recorded. One hundred and fourteen total hip replacements in 104 patients: 54 females and 50 males (52%/48%). Follow-up of 5.7 years (range, 5-6.2years). Average age 56.8years (range, 42-75years). Clinical evaluation the Merle d'Aubigné score improved 6.8 points and from the initianl Harris Hip Score 47.3 to 93.1 points at last follow up. Radiographic evaluation shows osteointegration in all stems. And in 6 cases (5.3% at 3 months subsidence was detected, average 1.4 mm (range 0-2.6 mm) with no clinical manifestation, 3 cases of subsidence were associated to intraoperative fractures (1 greater trochanter and 2 in the calcar area, all resolved with wire cerclaje). Subjective evaluation: 86 cases (82.6%) excellent, 9 patients (8.6%) good, 6 cases (5.9%) satisfactory and 3 cases (2.9%) poor. All poor results linked to the intraoperative complications. No patient lost during follow up period. No femoral pain dislocation or aseptic or loosening detected. All implants were in situ at last follow up. The radiological results confirm the benefits of this type of stem with good osteointegration. The clinical and subjective results are promising. With good surgical technical and without complications the risk of aseptic loosening should be absent or minimal. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Beginning hip arthroscopy: indications, positioning, portals, basic techniques, and complications.
Smart, L Ryan; Oetgen, Matthew; Noonan, Benjamin; Medvecky, Michael
2007-12-01
Hip arthroscopy is becoming increasingly popular for the diagnosis and treatment of hip pathology, and the indications continue to evolve. The two most common approaches are the supine and lateral decubitus position. Both approaches can be performed effectively; however, each approach has its own benefits and drawbacks. In this review we will describe the indications for hip arthroscopy, the pros and cons of each approach, and the necessary equipment, portals, portal placement, commercially available distraction devices, and complications.
Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.
Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2010-09-01
The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r=-0.25), or between the neck-shaft angle and the femoral anteversion (r=0.23). The neck-shaft angle, the femoral anteversion, and the CT migration percentage were significantly larger, and the femoral offset was significantly smaller, in patients with the Gross Motor Functional Classification System (GMFCS) level IV/V (nonwalking children) and SQ type, than in patients with GMFCS level II/III (mostly walking children) and SD type. The 3-dimensional femoral geometry in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. Our data indicate that 3-dimensional evaluation is accurate and useful for analysis of the femur and acetabulum in CP, and that the extent of coxa valga and femoral anteversion is more severe in the patients with GMFCS level IV/V and SQ type. Level IV.
Ultrasonic influence on evolution of disordered dislocation structures
NASA Astrophysics Data System (ADS)
Bachurin, D. V.; Murzaev, R. T.; Nazarov, A. A.
2017-12-01
Evolution of disordered dislocation structures under ultrasonic influence is studied in a model two-dimensional grain within the discrete-dislocation approach. Non-equilibrium grain boundary state is mimicked by a mesodefect located at the corners of the grain, stress field of which is described by that of a wedge junction disclination quadrupole. Significant rearrangement related to gliding of lattice dislocations towards the grain boundaries is found, which results in a noticeable reduction of internal stress fields and cancel of disclination quadrupole. The process of dislocation structure evolution passes through two stages: rapid and slow. The main dislocation rearrangement occurs during the first stage. Reduction of internal stress fields is associated with the number of dislocations entered into the grain boundaries. The change of misorientation angle due to lattice dislocations absorbed by the grain boundaries is evaluated. Amplitude of ultrasonic treatment significantly influences the relaxation of dislocation structure. Preliminary elastic relaxation of dislocation structure does not affect substantially the results of the following ultrasonic treatment. Substantial grain size dependence of relaxation of disordered dislocation systems is found. Simulation results are consistent with experimental data.
Celiktas, Mustafa; Kose, Ozkan; Turan, Adil; Guler, Ferhat; Ors, Cagri; Togrul, Emre
2017-01-01
The purpose of this retrospective study is to report the clinical and radiological outcome of total hip arthroplasty in patients with previous hip arthrodesis. We retrospectively reviewed 28 (40 hips) prospectively followed patients in whom ankylosed hips were converted to total hip arthroplasty (THA) between 2010 and 2014 in our institution. The average age at the time of the conversion operation was 40.8 ± 9.8 years (range 24-62). The ankylosis had lasted 20.4 ± 13.0 years (range 3-56) before conversion surgery. The etiology of the ankylosis was septic arthritis in 10 (25%), post-traumatic hip osteoarthritis in 8 (20%), developmental hip dysplasia in 6 (15%), rheumatoid arthritis in 6 (15%), primary osteoarthritis in 5 (12.5%) and ankylosing spondylitis in 5 (12.5%) hips. The indications for arthroplasty were intractable low back pain in 14 (50%), hip pain in 24 (85.7%), and ipsilateral knee pain in 19 (67.8%) patients. Harris Hip Score (HHS) was used to rate the clinical results before and after the surgery. Radiographic evaluations included component malposition and loosening. All complications during the study period were recorded. The mean follow-up period was 39.9 ± 10.6 months (range 24-60). The mean preoperative HHS was 33.3 ± 8.6 (range 18-50) and the mean HHS at the final follow-up was 74.9 ± 8.6 (range 52-97). There was a statistically significant increase in HHS (p = 0.0001). HHS was excellent in 1, good in 6, fair in 14 and poor in 7 patients. Increase in HHS was lower than 20 points in one patient (18 points), and one patient required two-staged exchange procedure due to deep infection. Thus, according to our success criteria (increase in HHS more than 20 points, radiographically stable implant, and no further surgical reconstruction), 92.8% (26/28) of patients had benefit from the surgery. Trendelenburg sign was positive in 12 hips. There was limb length inequality in 11 patients (mean 0.5 cm, range 1-3 cm). No patients had heterotopic ossification, sciatic nerve palsy or dislocation. There were five intra-operative fractures of the greater trochanter that were treated with cable wiring. One patient had trochanteric avulsion injury and was treated with trochanteric grip and cables. One patient (2.5%) had deep infection one year after the conversion THA and was treated with two-staged exchange procedure. Conversion hip arthroplasty is an effective treatment method which provides functional recovery and patient satisfaction. However, a proper surgical technique and planning is necessary to minimize the complications.
Hopley, Colin; Stengel, Dirk; Ekkernkamp, Axel; Wich, Michael
2010-06-11
To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.
Microstructural comparison of the kinematics of discrete and continuum dislocations models
NASA Astrophysics Data System (ADS)
Sandfeld, Stefan; Po, Giacomo
2015-12-01
The Continuum Dislocation Dynamics (CDD) theory and the Discrete Dislocation Dynamics (DDD) method are compared based on concise mathematical formulations of the coarse graining of discrete data. A numerical tool for converting from a discrete to a continuum representation of a given dislocation configuration is developed, which allows to directly compare both simulation approaches based on continuum quantities (e.g. scalar density, geometrically necessary densities, mean curvature). Investigating the evolution of selected dislocation configurations within analytically given velocity fields for both DDD and CDD reveals that CDD contains a surprising number of important microstructural details.
NASA Astrophysics Data System (ADS)
Tran, H.-S.; Tummala, H.; Duchene, L.; Pardoen, T.; Fivel, M.; Habraken, A. M.
2017-10-01
The interaction of a pure screw dislocation with a Coherent Twin Boundary Σ3 in copper was studied using the Quasicontinuum method. Coherent Twin Boundary behaves as a strong barrier to dislocation glide and prohibits slip transmission across the boundary. Dislocation pileup modifies the stress field at its intersection with the Grain Boundary (GB). A methodology to estimate the strength of the barrier for a dislocation to slip across CTB is proposed. A screw dislocation approaching the boundary from one side either propagates into the adjacent twin grain by cutting through the twin boundary or is stopped and increases the dislocation pileup amplitude at the GB. Quantitative estimation of the critical stress for transmission was performed using the virial stress computed by Quasicontinuum method. The transmission mechanism and critical stress are in line with the literature. Such information can be used as input for dislocation dynamic simulations for a better modeling of grain boundaries.
Amodio, John; Rivera, Rafael; Pinkney, Lynne; Strubel, Naomi; Fefferman, Nancy
2006-08-01
The arterial vascularity of the hip has been investigated in normal infants using duplex Doppler sonography. This study addressed the differences in hip vascularity in infants with respect to gender and acetabular morphology. To determine whether there is a relationship between the resistive index of the vessels of the femoral chondroepiphysis and the alpha angle in normal infant hips and in those with developmental dysplasia of the hip. We studied 76 hips (38 patients) with gray-scale and power Doppler US. The patients were referred because of a possible abnormal clinical hip examination or had risk factors for developmental dysplasia of the hip. The infants ranged in age from 1 day to 6 weeks. There were 13 boys and 25 girls. Gray-scale images were initially performed in the coronal and transverse planes to evaluate acetabular morphology, alpha angle and position of the femoral chondroepiphysis relative to the acetabulum. The hips were then examined with power Doppler US, in both sagittal and transverse planes, to identify arterial vessels within the femoral epiphysis. Resistive indices were then recorded from the spectral analysis in each vessel identified. Each examination was performed by one of five pediatric radiologists. Mixed model regression was used to assess the relationship between resistive index and alpha angle, age and gender. Of the 76 hips, 34 had an alpha angle of 60 degrees or greater and were classified as normal, 26 had an alpha angle between 50 degrees and 59 degrees and were classified as immature, and 13 had an alpha angle of less than 50 degrees and were either subluxed or dislocated at the time of examination. At least two vessels were documented in each femoral epiphysis except in three hips, in which no vessels could be documented because of technical factors. There was a statistically significant linear relationship between the alpha angle and resistive index, such that the resistive index tended to rise with increasing alpha angle (P=0.0022). In addition, female infants had a significantly higher average resistive index than the average resistive index in male infants with the same alpha angle (P=0.0005). There is a direct linear relationship between alpha angle and resistive index in the infant hip. Female infants have a higher average resistive index than male infants. We believe that these results might serve as a model for predicting an infant hip at risk of ischemia. In addition, the fact that lower resistive indices of the femoral epiphysis are associated with acetabular dysplasia might help explain the documented low incidence of avascular necrosis in untreated hip dysplasia.
A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty
Marsland, Daniel; Mears, Simon C.
2012-01-01
Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704
Buttaro, Martín A; Slullitel, Pablo A; García Mansilla, Agustín M; Carlucci, Sofía; Comba, Fernando M; Zanotti, Gerardo; Piccaluga, Francisco
2017-03-01
Incapacitating articular sequelae in the hip joint have been described for patients with late effects of poliomyelitis. In these patients, total hip arthroplasty (THA) has been associated with a substantial rate of dislocation. This study was conducted to evaluate the long-term clinical and radiologic outcomes of unconstrained THA in this specific group of patients. The study included 6 patients with ipsilateral polio who underwent primary THA between 1985 and 2006. Patients with polio who underwent THA on the nonparalytic limb were excluded. Mean follow-up was 119.5 months (minimum, 84 months). Clinical outcomes were evaluated with the modified Harris Hip Score (mHHS) and the visual analog scale (VAS) pain score. Radiographs were examined to identify the cause of complications and determine the need for revision surgery. All patients showed significantly better functional results when preoperative and postoperative mHHS (67.58 vs 87.33, respectively; P=.002) and VAS pain score (7.66 vs 2, respectively; P=.0003) were compared. Although 2 cases of instability were diagnosed, only 1 patient needed acetabular revision as a result of component malpositioning. None of the patients had component loosening, osteolysis, or infection. Unconstrained THA in the affected limb of patients with poliomyelitis showed favorable long-term clinical results, with improved function and pain relief. Nevertheless, instability may be a more frequent complication in this group of patients compared with the general population. [Orthopedics. 2017; 40(2):e255-e261.]. Copyright 2016, SLACK Incorporated.
Yang, Baohui; Lu, Teng
2017-01-01
For patients with AS and lower cervical spine fractures, surgical methods have mainly included the single anterior approach, single posterior approach, and combined anterior-posterior approach. However, various surgical procedures were utilized because the fractures have not been clearly classified according to presence of displacement in these previous studies. Consequently, controversies have been raised regarding the selection of the surgical procedure. This study retrospective analysis was conducted in 12 patients with AS and lower cervical spine fractures and dislocations and explored single-session combined anterior-posterior approach for the treatment of AS with obvious displaced lower cervical spine fractures and dislocations which has demonstrated advantages such as good stabilization, satisfied fracture healing, and easy postoperative cares. However, to some extent, the difficulty and risk of this approach should be considered. Attention should be paid to the prevention of perioperative complications. PMID:28133616
Early Outcomes of Primary Total Hip Arthroplasty After Prior Lumbar Spinal Fusion.
Barry, Jeffrey J; Sing, David C; Vail, Thomas P; Hansen, Erik N
2017-02-01
The coexistence of degenerative hip disease and spinal pathology is not uncommon with the number of surgical treatments performed for each condition increasing annually. The limited research available suggests spinal pathology portends less pain relief and worse outcomes after total hip arthroplasty (THA). We hypothesize that primary THA patients with preexisting lumbar spinal fusions (LSF) experience worse early postoperative outcomes. This study is a retrospective matched cohort study. Primary THA patients at 1 institution who had undergone prior LSF (spine arthrodesis-hip arthroplasty [SAHA]) were identified and matched to controls of primary THA without LSF. Early outcomes (<90 days) were compared. From 2012 to 2014, 35 SAHA patients were compared to 70 matched controls. Patients were similar in age, sex, American Society of Anesthesiologist score, body mass index, and Charlson Comorbidity Index. SAHA patients had higher rates of complications (31.4% vs 8.6%, P = .008), reoperation (14.3% vs 2.9%, P = .040), and general anesthesia (54.3% vs 5.7%, P = .0001). Bivariate analysis demonstrated SAHA to predict reoperation (odds ratio, 5.67; P = .045) and complications (odds ratio, 4.89; P = .005). With the numbers available, dislocations (0% vs 2.8%), infections (0% vs 8.6%), readmissions, postoperative walking distance, and disposition only trended to favor controls (P > .05). Comparing controls to SAHA patients with <3 or ≥3 levels fused, longer fusions had increased cumulative postoperative narcotic consumption (mean morphine equivalents, 44.3 vs 46.9 vs 169.4; P = .001). Patients with preexisting LSF experience worse early outcomes after primary THA including higher rates of complications and reoperation. Lower rates of neuraxial anesthesia and increased narcotic usage represent potential contributors. The complex interplay between the lumbar spine and hip warrants attention and further investigation. Copyright © 2016 Elsevier Inc. All rights reserved.
Zwawi, Mohammed A; Moslehy, Faissal A; Rose, Christopher; Huayamave, Victor; Kassab, Alain J; Divo, Eduardo; Jones, Brendan J; Price, Charles T
2017-08-01
This study utilized a computational biomechanical model and applied the least energy path principle to investigate two pathways for closed reduction of high grade infantile hip dislocation. The principle of least energy when applied to moving the femoral head from an initial to a final position considers all possible paths that connect them and identifies the path of least resistance. Clinical reports of severe hip dysplasia have concluded that reduction of the femoral head into the acetabulum may occur by a direct pathway over the posterior rim of the acetabulum when using the Pavlik harness, or by an indirect pathway with reduction through the acetabular notch when using the modified Hoffman-Daimler method. This computational study also compared the energy requirements for both pathways. The anatomical and muscular aspects of the model were derived using a combination of MRI and OpenSim data. Results of this study indicate that the path of least energy closely approximates the indirect pathway of the modified Hoffman-Daimler method. The direct pathway over the posterior rim of the acetabulum required more energy for reduction. This biomechanical analysis confirms the clinical observations of the two pathways for closed reduction of severe hip dysplasia. The path of least energy closely approximated the modified Hoffman-Daimler method. Further study of the modified Hoffman-Daimler method for reduction of severe hip dysplasia may be warranted based on this computational biomechanical analysis. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1799-1805, 2017. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.
Chammout, Ghazi; Muren, Olle; Laurencikas, Evaldas; Bodén, Henrik; Kelly-Pettersson, Paula; Sjöö, Helene; Stark, André; Sköldenberg, Olof
2017-01-01
Background and purpose Total hip replacement (THR) is the preferred method for the active and lucid elderly patient with a displaced femoral neck fracture (FNF). Controversy still exists regarding the use of cemented or uncemented stems in these patients. We compared the effectiveness and safety between a modern cemented, and a modern uncemented hydroxyapatite-coated femoral stem in patients 65–79 years of age who were treated with THR for displaced FNF. Patients and methods In a single-center, single-blinded randomized controlled trial, we included 69 patients, mean age 75 (65–79) and with a displaced FNF (Garden III–IV). 35 patients were randomized to a cemented THR and 34 to a reverse-hybrid THR with an uncemented stem. Primary endpoints were: prevalence of all hip-related complications and health-related quality of life, evaluated with EuroQol-5D (EQ-5D) index up to 2 years after surgery. Secondary outcomes included: overall mortality, general medical complications, and hip function. The patients were followed up at 3, 12, and 24 months. Results According to the calculation of sample size, 140 patients would be required for the primary endpoints, but the study was stopped when only half of the sample size was included (n = 69). An interim analysis at that time showed that the total number of early hip-related complications was substantially higher in the uncemented group, 9 (among them, 3 dislocations and 4 periprosthetic fractures) as compared to 1 in the cemented group. The mortality and functional outcome scores were similar in the 2 groups. Interpretation We do not recommend uncemented femoral stems for the treatment of elderly patients with displaced FNFs. PMID:27967333
Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System.
Kurosaka, Kenji; Fukunishi, Shigeo; Fukui, Tomokazu; Nishio, Shoji; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Daimon, Takashi; Yoshiya, Shinichi
2016-07-01
Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.]. Copyright 2016, SLACK Incorporated.
Modeling and 2-D discrete simulation of dislocation dynamics for plastic deformation of metal
NASA Astrophysics Data System (ADS)
Liu, Juan; Cui, Zhenshan; Ou, Hengan; Ruan, Liqun
2013-05-01
Two methods are employed in this paper to investigate the dislocation evolution during plastic deformation of metal. One method is dislocation dynamic simulation of two-dimensional discrete dislocation dynamics (2D-DDD), and the other is dislocation dynamics modeling by means of nonlinear analysis. As screw dislocation is prone to disappear by cross-slip, only edge dislocation is taken into account in simulation. First, an approach of 2D-DDD is used to graphically simulate and exhibit the collective motion of a large number of discrete dislocations. In the beginning, initial grains are generated in the simulation cells according to the mechanism of grain growth and the initial dislocation is randomly distributed in grains and relaxed under the internal stress. During the simulation process, the externally imposed stress, the long range stress contribution of all dislocations and the short range stress caused by the grain boundaries are calculated. Under the action of these forces, dislocations begin to glide, climb, multiply, annihilate and react with each other. Besides, thermal activation process is included. Through the simulation, the distribution of dislocation and the stress-strain curves can be obtained. On the other hand, based on the classic dislocation theory, the variation of the dislocation density with time is described by nonlinear differential equations. Finite difference method (FDM) is used to solve the built differential equations. The dislocation evolution at a constant strain rate is taken as an example to verify the rationality of the model.
Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa
2012-08-01
Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.
Bartels, Ronald H M A; Donk, Roland
2002-10-01
Postinjury cervical spine instability typically requires surgical treatment in the acute or semiacute stage. The authors, however, report on three patients with older (> 8 weeks) untreated bilateral cervical facet dislocation. In two patients they attempted a classic anterior-posterior-anterior approach but failed. The misalignment in the second stage of the procedure could not be corrected, and they had to add a fourth, posterior, stage. To avoid the fourth stage, thereby reducing operating time and risk of neurological damage while turning the patient, they propose the following sequence: 1) a posterior approach to perform a complete facetectomy bilaterally with no attempt to reduce the dislocation; 2) an anterior microscopic discectomy with reduction of the dislocation and anterior fixation; and 3) posterior fixation. This sequence of procedures was successfully performed in the third patient. Based on this experience, they suggest that in cases of nonacute bilateral cervical facet dislocations the operating sequence should be posterior-anterior-posterior.
Mahan, Susan T.; Katz, Jeffrey N.; Kim, Young-Jo
2009-01-01
Background: The United States Preventive Services Task Force recently determined that they could not recommend any screening strategies for developmental dysplasia of the hip. Disparate findings in the literature and treatment-related problems have led to confusion about whether or not to screen for this disorder. The purpose of the present study was to determine, with use of expected-value decision analysis, which of the following three strategies leads to the best chance of having a non-arthritic hip by the age of sixty years: (1) no screening for developmental dysplasia of the hip, (2) universal screening of newborns with both physical examination and ultrasonography, or (3) universal screening with physical examination but only selective use of ultrasonography for neonates considered to be at high risk. Methods: Developmental dysplasia of the hip, avascular necrosis, and the treatment algorithm were carefully defined. The outcome was determined as the probability of any neonate having a non-arthritic hip through the age of sixty years. A decision tree was then built with decision nodes as described above, and chance node probabilities were determined from a thorough review of the literature. Foldback analysis and sensitivity analyses were performed. Results: The expected value of a favorable hip outcome was 0.9590 for the strategy of screening all neonates with physical examination and selective use of ultrasonography, 0.9586 for screening all neonates with physical examination and ultrasonography, and 0.9578 for no screening. A lower expected value implies a greater risk for the development of osteoarthritis as a result of developmental dysplasia of the hip or avascular necrosis; thus, the optimum strategy was selective screening. This model was robust to sensitivity analysis, except when the rate of missed dysplasia rose as high as 4/1000 or the rate of treated hip subluxation/dislocation was the same; then, the optimum strategy was to screen all neonates with both physical examination and ultrasonography. Conclusions: Our decision analytic model indicated that the optimum strategy, associated with the highest probability of having a non-arthritic hip at the age of sixty years, was to screen all neonates for hip dysplasia with a physical examination and to use ultrasonography selectively for infants who are at high risk. Additional data on the costs and cost-effectiveness of these screening policies are needed to guide policy recommendations. Level of Evidence: Economic and decision analysis Level II. See Instructions to Authors for a complete description of levels of evidence. PMID:19571094
NASA Astrophysics Data System (ADS)
Xia, Shengxu; El-Azab, Anter
2015-07-01
We present a continuum dislocation dynamics model that predicts the formation of dislocation cell structure in single crystals at low strains. The model features a set of kinetic equations of the curl type that govern the space and time evolution of the dislocation density in the crystal. These kinetic equations are coupled to stress equilibrium and deformation kinematics using the eigenstrain approach. A custom finite element method has been developed to solve the coupled system of equations of dislocation kinetics and crystal mechanics. The results show that, in general, dislocations self-organize in patterns under their mutual interactions. However, the famous dislocation cell structure has been found to form only when cross slip is implemented in the model. Cross slip is also found to lower the yield point, increase the hardening rate, and sustain an increase in the dislocation density over the hardening regime. Analysis of the cell structure evolution reveals that the average cell size decreases with the applied stress, which is consistent with the similitude principle.
Chronic bilateral dislocation of temporomandibular joint.
Shakya, S; Ongole, R; Sumanth, K N; Denny, C E
2010-01-01
Dislocation of the condyle of the mandible is a common condition that may occur in an acute or chronic form. It is characterised by inability to close the mouth with or without pain. Dislocation has to be differentiated from subluxation which is a self reducible condition. Dislocation can occur in any direction with anterior dislocation being the commonest one. Various predisposing factors have been associated with dislocation like muscle fatigue and spasm, the defect in the bony surface like shallow articular eminence, and laxity of the capsular ligament. People with defect in collagen synthesis like Ehler Danlos syndrome, Marfan syndrome are said to be genetically predisposed to this condition. Various treatment modalities have been used ranging from conservative techniques to surgical methods. Acute dislocations can be reduced manually or with conservative approach and recurrent and chronic cases can be reduced by surgical intervention. Though the dislocation in our case was 4 months a simple manual reduction proved to be successful. We believe that manual reduction can be attempted as first line of treatment prior to surgical intervention.
Electron energy can oscillate near a crystal dislocation
Li, Mingda; Cui, Wenping; Dresselhaus, Mildred S.; ...
2017-01-25
Crystal dislocations govern the plastic mechanical properties of materials but also affect the electrical and optical properties. However, a fundamental and quantitative quantum field theory of a dislocation has remained undiscovered for decades. Here in this article we present an exactly-solvable one-dimensional quantum field theory of a dislocation, for both edge and screw dislocations in an isotropic medium, by introducing a new quasiparticle which we have called the ‘dislon’. The electron-dislocation relaxation time can then be studied directly from the electron self-energy calculation, which is reducible to classical results. In addition, we predict that the electron energy will experience anmore » oscillation pattern near a dislocation. Compared with the electron density’s Friedel oscillation, such an oscillation is intrinsically different since it exists even with only single electron is present. With our approach, the effect of dislocations on materials’ non-mechanical properties can be studied at a full quantum field theoretical level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Mingda; Cui, Wenping; Dresselhaus, Mildred S.
Crystal dislocations govern the plastic mechanical properties of materials but also affect the electrical and optical properties. However, a fundamental and quantitative quantum field theory of a dislocation has remained undiscovered for decades. Here in this article we present an exactly-solvable one-dimensional quantum field theory of a dislocation, for both edge and screw dislocations in an isotropic medium, by introducing a new quasiparticle which we have called the ‘dislon’. The electron-dislocation relaxation time can then be studied directly from the electron self-energy calculation, which is reducible to classical results. In addition, we predict that the electron energy will experience anmore » oscillation pattern near a dislocation. Compared with the electron density’s Friedel oscillation, such an oscillation is intrinsically different since it exists even with only single electron is present. With our approach, the effect of dislocations on materials’ non-mechanical properties can be studied at a full quantum field theoretical level.« less
First-time anterior shoulder dislocations: should they be arthroscopically stabilised?
Sedeek, Sedeek Mohamed; Bin Abd Razak, Hamid Rahmatullah; Ee, Gerard WW; Tan, Andrew HC
2014-01-01
The glenohumeral joint is inherently unstable because the large humeral head articulates with the small shadow glenoid fossa. Traumatic anterior dislocation of the shoulder is a relatively common athletic injury, and the high frequency of recurrent instability in young athletes after shoulder dislocation is discouraging to both the patient and the treating physician. Management of primary traumatic shoulder dislocation remains controversial. Traditionally, treatment involves initial immobilisation for 4–6 weeks, followed by functional rehabilitation. However, in view of the high recurrence rates associated with this traditional approach, there has been an escalating interest in determining whether immediate surgical intervention can lower the rate of recurrent shoulder dislocation, improving the patient’s quality of life. This review article aims to provide an overview of the nature and pathogenesis of first-time primary anterior shoulder dislocations, the widely accepted management modalities, and the efficacy of primary surgical intervention in first-time primary anterior shoulder dislocations. PMID:25631890
Fast Fourier transform discrete dislocation dynamics
NASA Astrophysics Data System (ADS)
Graham, J. T.; Rollett, A. D.; LeSar, R.
2016-12-01
Discrete dislocation dynamics simulations have been generally limited to modeling systems described by isotropic elasticity. Effects of anisotropy on dislocation interactions, which can be quite large, have generally been ignored because of the computational expense involved when including anisotropic elasticity. We present a different formalism of dislocation dynamics in which the dislocations are represented by the deformation tensor, which is a direct measure of the slip in the lattice caused by the dislocations and can be considered as an eigenstrain. The stresses arising from the dislocations are calculated with a fast Fourier transform (FFT) method, from which the forces are determined and the equations of motion are solved. Use of the FFTs means that the stress field is only available at the grid points, which requires some adjustments/regularizations to be made to the representation of the dislocations and the calculation of the force on individual segments, as is discussed hereinafter. A notable advantage of this approach is that there is no computational penalty for including anisotropic elasticity. We review the method and apply it in a simple dislocation dynamics calculation.
Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul
2018-01-01
While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.
Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P
2016-12-01
Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and for dislocation (8 vs. 1, P=0.031). Mean PMA scores at last follow-up were comparable in the AVN group (17.65±1.27 [range, 10-18]) and osteoarthritis group (17.59±1.32 [range, 14-18]) (P=0.139). Osseointegration was also similar in the two groups: global Engh score, 26.51±1.81 (range, 14-27) for AVN and 26.84±0.91 (range, 19.5-27) for osteoarthritis (P=0.065); femoral ARA score, 5.83±0.46 (range, 3-6) for AVN and 5.90±0.42 (range, 3-6) for osteoarthritis (P=0.064); and cup ARA score, 5.74±0.67 (range, 3-6) for AVN and 5.78±0.66 (range, 3-6) for osteoarthritis (P=0.344). Survival in this study was good and consistent with recent data on AVN, with no difference between AVN and osteoarthritis. Revisions for any cause or for dislocation were more common after THA for AVN. Functional outcomes were similar in the AVN and osteoarthritis groups. An anatomical cementless prosthesis combined with metal-on-metal 28-mm bearing provides durable good outcomes. III, non-randomized comparison of two prospective cohorts. Published by Elsevier Masson SAS.
Dural ectasia in a child with Larsen syndrome.
Jain, Viral V; Anadio, Jennifer M; Chan, Gilbert; Sturm, Peter F; Crawford, Alvin H
2014-01-01
We present a case of an incidental finding of dural ectasia in a child diagnosed with Larsen syndrome. Larsen syndrome is a rare inherited disorder of connective tissue characterized by facial dysmorphism, congenital joint dislocations of the hips, knees and elbows, and deformities of the hands and feet. Dural ectasia is as an abnormal expansion of the dural sac surrounding the spinal cord and may result in spinal morphologic changes, instability, and spontaneous dislocation. To the best of our knowledge, the presence of dural ectasia in Larsen syndrome has not previously been reported. A 6-year-old boy diagnosed with Larsen syndrome presented with an upper thoracic curve measuring 74 degrees, a right thoracic curve measuring 65 degrees, and significant cervicothoracic kyphosis with 50% anterior subluxation of C6 on C7 and C7 on T1. Advanced imaging studies showed dural ectasia (evidenced by spinal canal and dural sac expansion), thinning of pedicles and lamina, and C4 and C6 pars defects with cervical foramen enlargement. The patient received growing rod instrumentation (attached to cervical spine fixation) by a combined anterior/posterior surgical approach using intraoperative halo. Complications included intraoperative medial breach (fully resolved), wound dehiscence, 2 instances of bilateral broken rods, and a broken cervical rod. Following 7 lengthening procedures, the patient underwent definitive fusion. Surgeons should be aware of the potential for dural ectasia in patients with Larsen syndrome. Its presence will cause difficulties in the surgical intervention for spinal deformity. Multiple factors must be considered, and surgical approach and technique will require modification to avoid complications. Although dural ectasia confounds surgical intervention in these patients, surgery still appears to outweigh the risks associated with delayed intervention. The presence of dural ectasia should not preclude surgical decompression and stabilization. This report adds to the body of knowledge on the treatment of Larsen syndrome by demonstrating the potential existence of dural ectasia and highlights the importance of careful and thorough preoperative evaluation and diagnostic imaging.
Field Dislocation Mechanics for heterogeneous elastic materials: A numerical spectral approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Djaka, Komlan Senam; Villani, Aurelien; Taupin, Vincent
Spectral methods using Fast Fourier Transform (FFT) algorithms have recently seen a surge in interest in the mechanics of materials community. The present work addresses the critical question of determining accurate local mechanical fields using FFT methods without artificial fluctuations arising from materials and defects induced discontinuities. Precisely, this work introduces a numerical approach based on intrinsic discrete Fourier transforms for the simultaneous treatment of material discontinuities arising from the presence of dislocations and from elastic stiffness heterogeneities. To this end, the elasto-static equations of the field dislocation mechanics theory for periodic heterogeneous materials are numerically solved with FFT inmore » the case of dislocations in proximity of inclusions of varying stiffness. An optimal intrinsic discrete Fourier transform method is sought based on two distinct schemes. A centered finite difference scheme for differential rules are used for numerically solving the Poisson-type equation in the Fourier space, while centered finite differences on a rotated grid is chosen for the computation of the modified Fourier–Green’s operator associated with the Lippmann–Schwinger-type equation. By comparing different methods with analytical solutions for an edge dislocation in a composite material, it is found that the present spectral method is accurate, devoid of any numerical oscillation, and efficient even for an infinite phase elastic contrast like a hole embedded in a matrix containing a dislocation. The present FFT method is then used to simulate physical cases such as the elastic fields of dislocation dipoles located near the matrix/inclusion interface in a 2D composite material and the ones due to dislocation loop distributions surrounding cubic inclusions in 3D composite material. In these configurations, the spectral method allows investigating accurately the elastic interactions and image stresses due to dislocation fields in the presence of elastic inhomogeneities.« less
Field Dislocation Mechanics for heterogeneous elastic materials: A numerical spectral approach
Djaka, Komlan Senam; Villani, Aurelien; Taupin, Vincent; ...
2017-03-01
Spectral methods using Fast Fourier Transform (FFT) algorithms have recently seen a surge in interest in the mechanics of materials community. The present work addresses the critical question of determining accurate local mechanical fields using FFT methods without artificial fluctuations arising from materials and defects induced discontinuities. Precisely, this work introduces a numerical approach based on intrinsic discrete Fourier transforms for the simultaneous treatment of material discontinuities arising from the presence of dislocations and from elastic stiffness heterogeneities. To this end, the elasto-static equations of the field dislocation mechanics theory for periodic heterogeneous materials are numerically solved with FFT inmore » the case of dislocations in proximity of inclusions of varying stiffness. An optimal intrinsic discrete Fourier transform method is sought based on two distinct schemes. A centered finite difference scheme for differential rules are used for numerically solving the Poisson-type equation in the Fourier space, while centered finite differences on a rotated grid is chosen for the computation of the modified Fourier–Green’s operator associated with the Lippmann–Schwinger-type equation. By comparing different methods with analytical solutions for an edge dislocation in a composite material, it is found that the present spectral method is accurate, devoid of any numerical oscillation, and efficient even for an infinite phase elastic contrast like a hole embedded in a matrix containing a dislocation. The present FFT method is then used to simulate physical cases such as the elastic fields of dislocation dipoles located near the matrix/inclusion interface in a 2D composite material and the ones due to dislocation loop distributions surrounding cubic inclusions in 3D composite material. In these configurations, the spectral method allows investigating accurately the elastic interactions and image stresses due to dislocation fields in the presence of elastic inhomogeneities.« less
NASA Astrophysics Data System (ADS)
Berkov, D. V.; Gorn, N. L.
2018-06-01
In this paper we present a simple and effective numerical method which allows a fast Fourier transformation-based evaluation of stress generated by dislocations with arbitrary directions and Burgers vectors if the (site-dependent) dislocation density is known. Our method allows the evaluation of the dislocation stress using a rectangular grid with shape-anisotropic discretization cells without employing higher multipole moments of the dislocation interaction coefficients. Using the proposed method, we first simulate the stress created by relatively simple non-homogeneous distributions of vertical edge and so-called ‘mixed’ dislocations in a disk-shaped sample, which is necessary to understand the dislocation behavior in more complicated systems. The main part of our research is devoted to the stress distribution in polycrystalline layers with the dislocation density rapidly varying with the distance to the layer bottom. Considering GaN as a typical example of such systems, we investigate dislocation-induced stress for edge and mixed dislocations, having random orientations of Burgers vectors among crystal grains. We show that the rapid decay of the dislocation density leads to many highly non-trivial features of the stress distributions in such layers and study in detail the dependence of these features on the average grain size. Finally we develop an analytical approach which allows us to predict the evolution of the stress variance with the grain size and compare analytical predictions with numerical results.
[Bone surgery for unstable hips in patients with cerebral palsy].
Poul, J; Pesl, M; Pokorná, M
2004-01-01
The aim of this retrospective study was to compare the efficacy of femoral osteotomy alone with that of osteotomy combined with an acetabular procedure in patients with unstable hips due to spastic cerebral palsy. Sixty-one hip joints in 50 patients who had shown distinct subluxation or dislocation of the joint were operated on. Eleven patients underwent bilateral surgery. Before bone surgery, soft-tissue release involving both the flexors and adductors was performed on 19 hips. Femoral osteotomy alone was performed on 29 hip joints and combined femoral and pelvic osteotomy was carried out on 32 joints.Twelve resections of the proximal femur in seven patients were evaluated as a separate group. All treated hip joints were assessed by clinical and radiographic examination at a follow-up of more than 5 years. The skiagraphs taken in a strictly neutral position of the lower limbs before surgery and at the final examination were evaluated on the basis of Reimers's migration index and Wiberg's centre-edge angle. The locomotor abilities of each child were categorized according to the Vojta scoring system for locomotor development. The range of motion in the treated hip joint was assessed using the standard S. F. T. R. method. The results obtained were statistically analyzed by the Kruskal- Wallis, one-way ANOVA test. A comparison of the results of femoral osteotomy alone with those of combined femoral and pelvic osteotomy showed that the post-operative values of the migration index and centre-edge angle, as compared with the pre-operative ones, were statistically higher (p<0.05) in the latter. In a long-term perspective, the surgery had no adverse effects on a natural development of locomotor abilities of the child. The children had higher scores by the modified Vojta rating system. There was no change in the range of motion in the treated hip joints after the operation. In 28, out of the 32 joints treated by combined femoral and pelvic osteotomy, Salter osteotomy was performed and it showed a high efficacy in providing hip joint stability. The main emphasis during surgery was placed on the maximum acetabular rotation laterally. Femoral osteotomy alone was less effective in providing hip joint stability; in addition, in order to achieve this, tilting of the proximal fragment to a varus position was generally higher than in combined operations. In three patients this treatment resulted in fixed adduction of the hip joint with negative consequences for movement. In the treatment of unstable hip joints a combination of varus derotation femoral osteotomy and pelvic osteotomy provides better containment of the joint than femoral osteotomy alone.
Wang, Baichuan; Hao, Yongqiang; Pu, Feifei; Jiang, Wenbo; Shao, Zengwu
2018-03-01
Prosthetic reconstruction may be a promising treatment for peri-acetabular malignant bone tumour; however, it is associated with a high complication rate. Therefore, prosthetic design and approach of prosthetic reconstruction after tumour resection warrant study. We retrospectively analyzed 11 patients with peri-acetabular malignant bone tumours treated by personalized 3D-printed hemipelvic prostheses after en bloc resection between 2015 and 2016. Pre-operative and post-operative pain at rest was assessed according to a 10-cm VAS score. The results of functional improvement were evaluated using the MSTS-93 score at the final follow-up. We also analyzed tumour recurrence, metastases, and complications associated with the reconstruction procedure. All patients were observed for six to 24 months with an average follow-up of 15.5 months. One patient had occasional pain of the involved hip at the final follow-up (VAS, pre vs. post 8 months: 3 vs. 2). The mean MSTS-93 score was 19.2 (range, 13-25). Hip dislocation was detected in two patients, while delayed wound healing occurred in one patient. One patient with mesenchymal chondrosarcoma had a left iliac bone metastasis. Local tumour recurrence was not observed. Reconstruction of bony defect after tumour resection using personalized 3D-printed hemipelvic prostheses can obtain acceptable functional results without severe complications. Based on previous reports and our results, we believe that reconstruction arthroplasty using 3D-printed hemipelvic prostheses will provide a promising alternative for those patients with peri-acetabular malignant bone tumours. Level IV, therapeutic study.
ERIC Educational Resources Information Center
Adjapong, Edmund S.
2017-01-01
This dissertation explores the context of urban science education as it relates to the achievement and engagement of urban youth. This study provides a framework for Hip-Hop Pedagogy, an approach to teaching and learning anchored in the creative elements of Hip-Hop culture, in STEM as an innovative approach to teaching and learning demonstrates…
Li, Haoxi; Yong, Zhiyao; Chen, Zhaoxiong; Huang, Yufeng; Lin, Zhoudan; Wu, Desheng
2017-01-01
Abstract Treatment of cervical fracture and dislocation by improving the anterior cervical technique. Anterior cervical approach has been extensively used in treating cervical spine fractures and dislocations. However, when this approach is used in the treatment of locked facet joints, an unsatisfactory intraoperative reduction and prying reduction increases the risk of secondary spinal cord injury. Thus, herein, the cervical anterior approach was improved. With distractor and screw elevation therapy during surgery, the restoration rate is increased, and secondary injury to the spinal cord is avoided. To discuss the feasibility of the surgical method of treating traumatic cervical spine fractures and dislocations and the clinical application. This retrospective study included the duration of patients’ hospitalization from January 2005 to June 2015. The potential risks of surgery (including death and other surgical complications) were explained clearly, and written consents were obtained from all patients before surgery. The study was conducted on 86 patients (54 males and 32 females, average age of 40.1 ± 5.6 years) with traumatic cervical spine fractures and dislocations, who underwent one-stage anterior approach treatment. The effective methods were evaluated by postoperative follow-up. The healing of the surgical incision was monitored in 86 patients. The follow-up duration was 18 to 36 (average 26.4 ± 7.1) months. The patients achieved bones grafted fusion and restored spine stability in 3 to 9 (average 6) months after the surgery. Statistically, significant improvement was observed by Frankel score, visual analog scale score, Japanese Orthopedic Association score, and correction rate of the cervical spine dislocation pre- and postoperative (P < .01). The modified anterior cervical approach is simple with a low risk but a good effect in reduction. In addition, it can reduce the risk of iatrogenic secondary spinal cord injury and maintain optimal cervical spine stability as observed during follow-ups. Therefore, it is suitable for clinical promotion and application. PMID:28658125
Model for threading dislocations in metamorphic tandem solar cells on GaAs (001) substrates
NASA Astrophysics Data System (ADS)
Song, Yifei; Kujofsa, Tedi; Ayers, John E.
2018-02-01
We present an approximate model for the threading dislocations in III-V heterostructures and have applied this model to study the defect behavior in metamorphic triple-junction solar cells. This model represents a new approach in which the coefficient for second-order threading dislocation annihilation and coalescence reactions is considered to be determined by the length of misfit dislocations, LMD, in the structure, and we therefore refer to it as the LMD model. On the basis of this model we have compared the average threading dislocation densities in the active layers of triple junction solar cells using linearly-graded buffers of varying thicknesses as well as S-graded (complementary error function) buffers with varying thicknesses and standard deviation parameters. We have shown that the threading dislocation densities in the active regions of metamorphic tandem solar cells depend not only on the thicknesses of the buffer layers but on their compositional grading profiles. The use of S-graded buffer layers instead of linear buffers resulted in lower threading dislocation densities. Moreover, the threading dislocation densities depended strongly on the standard deviation parameters used in the S-graded buffers, with smaller values providing lower threading dislocation densities.
Giugale, Juan Marcelo; Wang, Juntian; Kaufmann, Robert A.; Fowler, John R.
2017-01-01
Background: Proximal interphalangeal (PIP) fracture dislocations remain a complex injury pattern to treat. There are several treatment methods available aimed to restore stability, preserve range of motion, and reconstitute the articular surface. This study looked at the mid-term clinical and radiographic results of open reduction internal fixation through a shotgun approach of comminuted PIP fracture dislocations. Methods: A retrospective review was conducted of all PIP fracture dislocations treated through a volar, shotgun approach at a single institution over a 15-year period. Patients identified were contacted and asked to return to the office for clinical and radiographic evaluation. Patient reported outcomes were assessed with the Michigan hand questionnaire (MHQ) and visual analog scale (VAS) for pain. Results: 5 patients returned to the office for further evaluation with average follow-up of 69 months (range, 33-133 months). 3 patients were found to have post traumatic arthritis on radiographs. 1 case had recurrent instability and one case had a deep infection, both necessitating further surgical intervention. Average PIP arc of motion was found to be 79°. Average VAS score of 0 and MHQ result of 95 (out of a possible score of 100) indicating no residual pain and excellent functionality of the affected hand. Conclusion: Open reduction internal fixation of comminuted PIP fracture dislocations utilizing the volar, shotgun approach provides excellent mid-term functional results despite the high incidence of post traumatic arthritis. PMID:29151999
Maruyama, Masaaki; Wakabayashi, Shinji; Ota, Hiroshi; Tensho, Keiji
2017-02-01
Acetabular bone deficiency, especially proximal and lateral deficiency, is a difficult technical problem during primary total hip arthroplasty (THA) in developmental dysplasia of the hip (DDH). We report a new reconstruction method using a medial-reduced cemented socket and additional bulk bone in conjunction with impaction morselized bone grafting (additional bulk bone grafting method). In a population of patients with acetabular dysplasia undergoing THA using a medial-reduced cemented socket and additional bulk bone with impacted morselized bone grafting, we evaluated (1) the radiographic appearance of bone graft; (2) the proportion of cups that developed loosening and subsequent revision; and (3) clinical results (outcome scores and complications). Forty percent of 330 THAs for DDH performed at one center between 1999 and 2009 were defined as shallow dysplastic hips. The additional bulk bone grafting method was performed on 102 THAs with shallow acetabulum (31% for DDH) at one center between 1999 and 2009. We used this approach and technique for shallow acetabuli when a cup protruded from the lateral acetabular edge in preoperative templating. The other 132 dysplastic hips without bone grafting had THA performed at the same periods and served as a control. Acetabuli were defined as shallow when the depth was less than or equal to one-fifth of the pelvic height (cranial-caudal length on radiograph). The additional bulk bone grafting technique was as follows: the resected femoral head was sectioned at 1 to 2 cm thickness, and a suitable size of the bulk bone graft was placed on the lateral iliac cortex and fixed by poly-L-lactate absorbable screws. Autologous impaction morselized bone grafting, with or without hydroxyapatite granules, was performed along with the implantation of a medial-reduced cemented socket. We defined an "incorporated" graft as remodeling and trabeculation including rounding off of the protruding edge of a graft beyond the socket. Radiographic criteria used for determining loosening were migration or a continuous radiolucent zone between the prosthesis/bone cement and host bone. Clinical outcomes were assessed using the Japanese Orthopaedic Association (JOA) and the Merle d'Aubigne and Postel score; complications were tallied from chart review. The followup was 10 ± 3 years (range, 6-15 years). One acetabular component (1%) with severe shallow and steep acetabuli showed definite radiographic evidence of loosening and was revised. Clinically, the mean JOA score for the hips treated with additional bulk bone grafting THA in this study improved from 39 ± 10 points preoperatively to 95 ± 5 points postoperatively (p < 0.05, paired t-test). The mean Merle d'Aubigne and Postel score for the hips improved from 7 ± 2 points to 17 ± 1 points (p < 0.05, paired t-test). Complications included a Trendelenburg sign in one hip, dislocation in one, and transient partial sciatic nerve palsy in one. Within 3 years 6 months postoperatively, 101 of 102 additional bulk bone grafting cases showed successful bone remodeling and bone graft reorientation without collapse on radiographs. Partial resorption of the additional bone graft on the lateral side was observed in two hips (2%) with socket abduction angles of < 35°. Achieving stable acetabular fixation is often challenging in the dysplastic hip, especially shallow acetabulum, and a variety of techniques have been described. Early results of combining bulk graft with impaction of morselized graft are promising. Although each surgical technique was well established, further investigation for clinical results of a combination of these techniques might be necessary to confirm longer term outcomes. Level IV, therapeutic study.
Chronological changes in functional cup position at 10 years after total hip arthroplasty.
Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko
2017-09-19
This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p<0.01). The maximum postoperative change in F-Ant was 17.0° anteriorly; 12 cases (21%) showed a postoperative change in F-Ant by >10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.
NASA Astrophysics Data System (ADS)
Geslin, Pierre-Antoine; Gatti, Riccardo; Devincre, Benoit; Rodney, David
2017-11-01
We propose a framework to study thermally-activated processes in dislocation glide. This approach is based on an implementation of the nudged elastic band method in a nodal mesoscale dislocation dynamics formalism. Special care is paid to develop a variational formulation to ensure convergence to well-defined minimum energy paths. We also propose a methodology to rigorously parametrize the model on atomistic data, including elastic, core and stacking fault contributions. To assess the validity of the model, we investigate the homogeneous nucleation of partial dislocation loops in aluminum, recovering the activation energies and loop shapes obtained with atomistic calculations and extending these calculations to lower applied stresses. The present method is also applied to heterogeneous nucleation on spherical inclusions.
Atlanto-occipital dislocation: Case report and discussion.
Asfaw, Tehetena; Chow, Bernard; Frederiksen, Ryan A
2011-01-01
Traumatic atlanto-occipital dislocation is an uncommon injury that frequently results in either a fatal outcome or severe neurologic deficit. This diagnosis must be considered for any patients who may have had cervical spine damage after high trauma, even in the absence of neurologic signs, as there have been reports of cases without neurologic impairment. In addition to radiographic examination, including lateral cervical radiographs, supplemental imaging with CT or MRI may be required to confirm diagnosis in equivocal cases, and to help in evaluation of bone and nervous structures. Moreover, these modalities allow measurement of the magnitude of dislocation and aid in classification of type of dislocation, which helps guide management. A systematic approach to evaluating the cranio-cervical relationship is critical to identifying atlanto-occipital dislocation. This case report presents and discusses imaging findings that will assist in the diagnosis of atlanto-occipital dislocation.
NASA Astrophysics Data System (ADS)
Adjapong, Edmund S.
This dissertation explores the context of urban science education as it relates to the achievement and engagement of urban youth. This study provides a framework for Hip-Hop Pedagogy, an approach to teaching and learning anchored in the creative elements of Hip-Hop culture, in STEM as an innovative approach to teaching and learning demonstrates the effect that Hip-Hop Pedagogy, as a culturally relevant approach to teaching has on teaching and learning in an urban science classroom. This study establishes practical tools and approaches, which were formed from by theory and research that transcend the traditional monolithic approaches to teaching science. Participants in this study are middle school students who attend an urban school in one of the largest school systems in the country. This research showed that as result of utilizing Hip-Hop pedagogical practices, students reported that they developed a deeper understanding of science content, students were more likely to identify as scientists, and students were provided a space and opportunities to deconstruct traditional classroom spaces and structures.
Terrier, Alexandre; Latypova, Adeliya; Guillemin, Maika; Parvex, Valérie; Guyen, Olivier
2017-03-01
Constrained devices, standard implants with large heads, and dual mobility systems have become popular options to manage instability after total hip arthroplasty (THA). Clinical results with these options have shown variable success rates and significant higher rates of aseptic loosening and mechanical failures with constrained implants. Literature suggests potential advantages of dual mobility, however little is known about its biomechanics. We present a comparative biomechanical study of a standard implant, a constrained implant, and a dual mobility system. A finite element analysis was developed to assess and compare these acetabular options with regard to the range of motion (ROM) to impingement, the angle of dislocation, the resistive torque, the volume of polyethylene (PE) with a stress above 80% of the elastic limit, and the interfacial cup/bone stress. Dual mobility implants provided the greatest ROM to impingement and allowed delaying subluxation and dislocation when compared to standard and constrained implants. Dual mobility also demonstrated the lowest resistive torque at subluxation while the constrained implant provided the greatest one. The lowest critical PE volume was observed with the dual mobility implant, and the highest stress at the interfaces was observed with the constrained implant. This study highlights the biomechanical advantages of dual mobility systems over constrained and standard implants, and is supported by the clinical results reported. Therefore, the use of dual mobility systems in situations at risk for instability should be advocated and constrained implants should be restricted to salvage situations.
NASA Astrophysics Data System (ADS)
Rezaei Mianroodi, Jaber; Svendsen, Bob
2015-04-01
The purpose of the current work is the development of a phase field model for dislocation dissociation, slip and stacking fault formation in single crystals amenable to determination via atomistic or ab initio methods in the spirit of computational material design. The current approach is based in particular on periodic microelasticity (Wang and Jin, 2001; Bulatov and Cai, 2006; Wang and Li, 2010) to model the strongly non-local elastic interaction of dislocation lines via their (residual) strain fields. These strain fields depend in turn on phase fields which are used to parameterize the energy stored in dislocation lines and stacking faults. This energy storage is modeled here with the help of the "interface" energy concept and model of Cahn and Hilliard (1958) (see also Allen and Cahn, 1979; Wang and Li, 2010). In particular, the "homogeneous" part of this energy is related to the "rigid" (i.e., purely translational) part of the displacement of atoms across the slip plane, while the "gradient" part accounts for energy storage in those regions near the slip plane where atomic displacements deviate from being rigid, e.g., in the dislocation core. Via the attendant global energy scaling, the interface energy model facilitates an atomistic determination of the entire phase field energy as an optimal approximation of the (exact) atomistic energy; no adjustable parameters remain. For simplicity, an interatomic potential and molecular statics are employed for this purpose here; alternatively, ab initio (i.e., DFT-based) methods can be used. To illustrate the current approach, it is applied to determine the phase field free energy for fcc aluminum and copper. The identified models are then applied to modeling of dislocation dissociation, stacking fault formation, glide and dislocation reactions in these materials. As well, the tensile loading of a dislocation loop is considered. In the process, the current thermodynamic picture is compared with the classical mechanical one as based on the Peach-Köhler force.
[Minimally invasive approaches to hip and knee joints for total joint replacement].
Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F
2004-11-01
The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.
Kruse, Christine; Rosenlund, Signe; Broeng, Leif; Overgaard, Søren
2018-01-01
The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; p<0.001) compared with the lateral approach group. The posterior approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; p<0.001) and mean abductor moment arm of 4.8mm (95% CI, -7.6 to -1.9; p = 0.001) compared with the lateral approach group. We found a larger cup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.
Xu, Shuozhi; Xiong, Liming; Chen, Youping; ...
2017-04-26
Dislocation/stacking fault interactions play an important role in the plastic deformation of metallic nanocrystals and polycrystals. These interactions have been explored in atomistic models, which are limited in scale length by high computational cost. In contrast, multiscale material modeling approaches have the potential to simulate the same systems at a fraction of the computational cost. In this paper, we validate the concurrent atomistic-continuum (CAC) method on the interactions between a lattice screw dislocation and a stacking fault (SF) in three face-centered cubic metallic materials—Ni, Al, and Ag. Two types of SFs are considered: intrinsic SF (ISF) and extrinsic SF (ESF).more » For the three materials at different strain levels, two screw dislocation/ISF interaction modes (annihilation of the ISF and transmission of the dislocation across the ISF) and three screw dislocation/ESF interaction modes (transformation of the ESF into a three-layer twin, transformation of the ESF into an ISF, and transmission of the dislocation across the ESF) are identified. Here, our results show that CAC is capable of accurately predicting the dislocation/SF interaction modes with greatly reduced DOFs compared to fully-resolved atomistic simulations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Shuozhi; Xiong, Liming; Chen, Youping
Dislocation/stacking fault interactions play an important role in the plastic deformation of metallic nanocrystals and polycrystals. These interactions have been explored in atomistic models, which are limited in scale length by high computational cost. In contrast, multiscale material modeling approaches have the potential to simulate the same systems at a fraction of the computational cost. In this paper, we validate the concurrent atomistic-continuum (CAC) method on the interactions between a lattice screw dislocation and a stacking fault (SF) in three face-centered cubic metallic materials—Ni, Al, and Ag. Two types of SFs are considered: intrinsic SF (ISF) and extrinsic SF (ESF).more » For the three materials at different strain levels, two screw dislocation/ISF interaction modes (annihilation of the ISF and transmission of the dislocation across the ISF) and three screw dislocation/ESF interaction modes (transformation of the ESF into a three-layer twin, transformation of the ESF into an ISF, and transmission of the dislocation across the ESF) are identified. Here, our results show that CAC is capable of accurately predicting the dislocation/SF interaction modes with greatly reduced DOFs compared to fully-resolved atomistic simulations.« less
Berber, Reshid; Pappas, Yannis; Khoo, Michael; Miles, Jonathan; Carrington, Richard; Skinner, John; Hart, Alister
2015-02-18
Over one million patients worldwide are estimated to have a metal-on-metal hip arthroplasty. To improve the management of these patients and reduce surgeon uncertainty regarding decision-making, we designed an Internet-enhanced multidisciplinary team (iMDT) working approach. From August 2012 to April 2014, the iMDT discussed 215 patients with 266 metal-on-metal hip arthroplasties. Of these, 236 primary arthroplasties (132 hip resurfacing and 104 total hip) were analyzed. The remaining thirty cases involved problematic revised hips and were therefore excluded. The possible recommendations of the iMDT were monitoring, further investigation, or surgery. The concordance between the recommendation and the actual management was used to assess the usefulness of this approach in reducing uncertainty in surgeon-level decision-making. The median Oxford Hip Score was 35 (range, 4 to 48), and median cobalt and chromium levels in whole blood were 3.54 ppb (range, 0.18 to 161.46 ppb) and 3.17 ppb (range, 0.20 to 100.67 ppb), respectively. Magnetic resonance imaging revealed abductor muscle atrophy in ninety-two (39%) of the hips and a pseudotumor in eighty (34%). The iMDT recommended monitoring of 146 (61.9%) of the hips, further investigation of thirty (12.7%), and surgery in sixty (25.4%). The actual outcome was concordant with the recommendation in 211 (91.7%) of the hips. Our iMDT approach to the metal-on-metal hip burden combines the tacit knowledge of an expert panel, regulatory guidance, and up-to-date evidence to improve decision-making among surgeons. The high level of concordance between the recommendation and the actual outcome, combined with the feasibility of the methods used, suggest that this method effectively reduces uncertainty among surgeons and may lead to improved patient outcomes. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Arthroscopy of the Nondistractable Hip: A Novel Extracapsular Approach
Doron, Ran; Amar, Eyal; Rath, Ehud; Sampson, Thomas; Ochiai, Derek; Matsuda, Dean K.
2014-01-01
Adequate traction to achieve hip joint distraction is essential for avoiding iatrogenic injury to the joint during hip arthroscopy. An inability to distract the joint is a relative contraindication for hip arthroscopy. This report describes a novel technique involving an extracapsular approach to gain safe access to a hip joint that fails a trial of traction during positioning for hip arthroscopy. The anterolateral portal is established under fluoroscopic guidance. The arthroscope is positioned on the lateral rim of the acetabulum. A shaver, introduced through a modified anterior portal, is used to facilitate capsular exposure. An arthroscopic capsular incision is made proximal to the lateral acetabular rim and extended anteriorly with a radiofrequency probe. Osteoplasty of the anterolateral acetabular rim is carried out with a burr while protecting the labrum. Distraction of the hip is then possible, allowing safe central-compartment access and subsequent chondrolabral procedures. PMID:25685682
Creep Deformation by Dislocation Movement in Waspaloy
Whittaker, Mark; Harrison, Will; Deen, Christopher; Rae, Cathie; Williams, Steve
2017-01-01
Creep tests of the polycrystalline nickel alloy Waspaloy have been conducted at Swansea University, for varying stress conditions at 700 °C. Investigation through use of Transmission Electron Microscopy at Cambridge University has examined the dislocation networks formed under these conditions, with particular attention paid to comparing tests performed above and below the yield stress. This paper highlights how the dislocation structures vary throughout creep and proposes a dislocation mechanism theory for creep in Waspaloy. Activation energies are calculated through approaches developed in the use of the recently formulated Wilshire Equations, and are found to differ above and below the yield stress. Low activation energies are found to be related to dislocation interaction with γ′ precipitates below the yield stress. However, significantly increased dislocation densities at stresses above yield cause an increase in the activation energy values as forest hardening becomes the primary mechanism controlling dislocation movement. It is proposed that the activation energy change is related to the stress increment provided by work hardening, as can be observed from Ti, Ni and steel results. PMID:28772421
Sampling Practices and Social Spaces: Exploring a Hip-Hop Approach to Higher Education
ERIC Educational Resources Information Center
Petchauer, Emery
2010-01-01
Much more than a musical genre, hip-hop culture exists as an animating force in the lives of many young adults. This article looks beyond the moral concerns often associated with rap music to explore how hip-hop as a larger set of expressions and practices implicates the educational experiences, activities, and approaches for students. The article…
[Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].
Bonnaire, F; Lein, T; Bula, P
2011-06-01
The objective of any surgical care of a trochanteric femoral fracture should be the achievement of a stable osteosynthesis that allows early full weight-bearing mobilisation of the patient, because long-term immobilisation soon becomes a vital threat to the affected patients who are usually elderly with correlating comorbidities. The anatomical references of the proximal femur and the structure of the hip joint contain some specifics that play an essential role in the incurrence of a trochanteric femoral fracture and the planning of the osteosynthesis as well. With reposition and fracture stabilisation particular importance must be attached to the collo-diaphyseal and the antetorsion angle so that they do not interfere with the functional interaction of the hip and knee joint. Uncomplex trochanteric fractures ordinarily stabilise sufficiently after reposition so that even an extramedullary implant can ensure full weight-bearing stability. With evermore distal fracture course and intertrochanteric comminution zone, rotational instability and pivot transfer of the fracture area to lateral and caudal are followed by an increase of the dislocating forces. These kinds of fractures (A2 and A3 according to the AO/ASIF classification) profit from an intramedullary and rotationally stable osteosynthesis. Basically primary total hip arthroplasty is a potential option for surgical care of a trochanteric fracture in elderly patients with relevant coxarthrosis. However this procedure can only be recommended in cases of a stable uncomplex fracture. The more the medial interlocking of the proximal femur is destroyed the more difficult it will be to primarily implant a total hip prosthesis with good offset and without a varus and rotational failure in the fracture zone.The current studies in the main show disadvantages due to increased complications in these patients, so that in cases of an unstable trochanteric fracture a primary osteosynthesis should be performed followed by total hip arthroplasty after fracture consolidation has occurred.
Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J
2018-05-01
Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.
[New varieties of lateral metatarsophalangeal dislocations of the great toe].
Bousselmame, N; Rachid, K; Lazrak, K; Galuia, F; Taobane, H; Moulay, I
2001-04-01
We report seven cases of traumatic dislocation of the great toe, detailing the anatomy, the mechanism of injury and the radiographic diagnosis. We propose an additional classification based on three hereto unreported cases. Between october 1994 and october 1997, we treated seven patients with traumatic dislocation of the first metatarso-phalangeal joint of the great toe. There were six men and one woman, mean age 35 years (range 24 - 44 years). Dislocation was caused by motor vehicle accidents in four cases and by falls in three. Diagnosis was made on anteroposterior, lateral and medial oblique radiographs. According to Jahss' classification, there was one type I and three type IIB dislocations. There was also one open lateral dislocation and two dorsomedial dislocations. Only these dorsomedial dislocations required open reduction, done via a dorsal approach. Mean follow-up was 17.5 months (range 9 - 24 months) in six cases. One patient was lost to follow-up. The outcome was good in six cases and poor in one (dorsomedial dislocation). Dislocation of the first metatarso-phalangeal joint of the great toe is an uncommon injury. In 1980, Jahss reported two cases and reviewed three others described in the literature. He proposed three types of dislocation based on the feasibility of closed reduction (type I, II and IIB). In 1991, Copeland and Kanat reported a unique case in which there was an association of IIA and IIB lesions. They proposed an addition to the classification (type IIC). In 1994, Garcia Mata et al. reported another case which had not been described by Jahss and proposed another addition. All dislocations reported to date have been sagittal dislocations. Pathological alteration of the collateral ligaments has not been previously reported. In our experience, we have seen one case of open lateral dislocation due, at surgical exploration, to medial ligament rupture and two cases of dorsomedial dislocation due, at surgical exploration, to lateral ligament rupture. We propose another additional classification with pure lateral dislocation (type III) and dorso-lateral dislocation (type IL or IIL+), which are related to the formerly described variants.
A spectral approach for discrete dislocation dynamics simulations of nanoindentation
NASA Astrophysics Data System (ADS)
Bertin, Nicolas; Glavas, Vedran; Datta, Dibakar; Cai, Wei
2018-07-01
We present a spectral approach to perform nanoindentation simulations using three-dimensional nodal discrete dislocation dynamics. The method relies on a two step approach. First, the contact problem between an indenter of arbitrary shape and an isotropic elastic half-space is solved using a spectral iterative algorithm, and the contact pressure is fully determined on the half-space surface. The contact pressure is then used as a boundary condition of the spectral solver to determine the resulting stress field produced in the simulation volume. In both stages, the mechanical fields are decomposed into Fourier modes and are efficiently computed using fast Fourier transforms. To further improve the computational efficiency, the method is coupled with a subcycling integrator and a special approach is devised to approximate the displacement field associated with surface steps. As a benchmark, the method is used to compute the response of an elastic half-space using different types of indenter. An example of a dislocation dynamics nanoindentation simulation with complex initial microstructure is presented.
[Characteristics in treatment of the hip in patients with Down syndrome].
Peterlein, C-D; Schiel, M; Timmesfeld, N; Schofer, M D; Eberhardt, O; Wirth, T; Fernandez, F F
2013-12-01
The treatment of hip instability in patients with Down syndrome is challenging. We have performed different pelvic osteotomies and corrections at the proximal femur for this indication. This retrospective study was conducted to evaluate the clinical and radiological outcome of each intervention. All in all, 166 patients with Down syndrome were treated at our orthopaedic department in the observation period. Problems related to the hip joint were diagnosed in 63 of those patients. Only patients who underwent surgery were included in this study. The charts and X-rays of these 31 patients were evaluated with respect to the following parameters: incidence of the hip problem, concomitant diseases, temporal progress, kind of operation method and date, duration of stay in the hospital, after-care, follow-on surgery related to complications, AC angle, CE angle, ACM angle, CCD angle, index of migration according to Reimers, classification of Bauer and Kerschbauer and general morphology of the femoral head. The group was compared with an age-matched group of 21 patients with hip dysplasia. Those patients underwent the same sort of operation in the same year. In the Morbus Down group, we performed surgery for preservation of the hip in 49 cases. This included 13 osteotomies according to Chiari, 11 triple osteotomies according to Tönnis, 10 corrections by femoral varus derotation osteotomy, 8 pelvic osteotomies according to Pemberton, 5 pelvic osteotomies according to Salter and 2 open reductions of the hip. With respect to the moment of surgery, we detected three peaks of age. There was no difference in course of disease and quantity of complications between the groups. Satisfactory results concerning clinical and radiological outcome were achieved predominantly by complete redirectional acetabular osteotomies. Half of the patients who were solely treated by femoral varus derotation osteotomy needed follow-on surgery in the form of pelvic osteotomy. Comparison of preoperative and postoperative range of motion of the hip joint between groups detected capsular insufficiency, increased ligamentous laxity and muscular hypotonia in patients with Down syndrome. Comparison of pelvic radiographs demonstrated significant improvement concerning measured angles in both groups. Preoperative values with respect to AC angle and CE angle were demonstrated to be lower in the hip dysplasia group (p < 0.01); whereas values for ACM angle were comparable between groups. Hypermobility and secondary dislocation of the hip joint is a common problem in patients with Down syndrome, which often requires surgical intervention at an early stage. According to our data and clinical results we suggest a complete redirectional acetabular osteotomy in combination with capsular plication for treatment of this challenging condition. Georg Thieme Verlag KG Stuttgart · New York.
Li, N.; Yadav, S. K.; Liu, X. -Y.; ...
2015-11-05
Using the in situ indentation of TiN in a high-resolution transmission electron microscope, the nucleation of full as well as partial dislocations has been observed from {001} and {111} surfaces, respectively. The critical elastic strains associated with the nucleation of the dislocations were analyzed from the recorded atomic displacements, and the nucleation stresses corresponding to the measured critical strains were computed using density functional theory. The resolved shear stress was estimated to be 13.8 GPa for the partial dislocation 1/6 <110> {111} and 6.7 GPa for the full dislocation ½ <110> {110}. Moreover, such an approach of quantifying nucleation stressesmore » for defects via in situ high-resolution experiment coupled with density functional theory calculation may be applied to other unit processes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerberich, W.W.
1992-12-31
Objective was to study fatigue where a combination of low temperature and cyclic loading produced cyclic cleavage in bcc Fe-base systems. Both dislocation dynamics and quasi-statics of crack growth were probed. This document reviews progress over the past 6 years: hydrogen embrittlement and cleavage, computations (stress near crack tip), dislocation emission from grain boundaries, fracture process zones, and understanding brittle fracture at the atomistic/dislocation scales and at the microscopic/macroscopic scale.
2006-07-01
dislocation-loop expansion . The new model was used to simulate the thermally reversible flow behaviour for C-S type two-step deformation, and the results are...implemented into the finite element software ABAQUS through a User MATerial subroutine (UMAT). A tangent modulus method [48] was used for the time...locking under a dislocation loop- expansion configuration. This approach was motivated by modern understanding of dislocation mechanisms for Ni3Al
Theory of electron–phonon–dislon interacting system—toward a quantized theory of dislocations
Li, Mingda; Tsurimaki, Yoichiro; Meng, Qingping; ...
2018-02-05
In this paper, we provide a comprehensive theoretical framework to study how crystal dislocations influence the functional properties of materials, based on the idea of a quantized dislocation, namely a 'dislon'. In contrast to previous work on dislons which focused on exotic phenomenology, here we focus on their theoretical structure and computational power. We first provide a pedagogical introduction that explains the necessity and benefits of taking the dislon approach and why the dislon Hamiltonian takes its current form. Then, we study the electron–dislocation and phonon–dislocation scattering problems using the dislon formalism. Both the effective electron and phonon theories aremore » derived, from which the role of dislocations on electronic and phononic transport properties is computed. Compared with traditional dislocation scattering studies, which are intrinsically single-particle, low-order perturbation and classical quenched defect in nature, the dislon theory not only allows easy incorporation of quantum many-body effects such as electron correlation, electron–phonon interaction, and higher-order scattering events, but also allows proper consideration of the dislocation's long-range strain field and dynamic aspects on equal footing for arbitrary types of straight-line dislocations. This means that instead of developing individual models for specific dislocation scattering problems, the dislon theory allows for the calculation of electronic structure and electrical transport, thermal transport, optical and superconducting properties, etc, under one unified theory. Furthermore, the dislon theory has another advantage over empirical models in that it requires no fitting parameters. The dislon theory could serve as a major computational tool to understand the role of dislocations on multiple materials' functional properties at an unprecedented level of clarity, and may have wide applications in dislocated energy materials.« less
Theory of electron–phonon–dislon interacting system—toward a quantized theory of dislocations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Mingda; Tsurimaki, Yoichiro; Meng, Qingping
In this paper, we provide a comprehensive theoretical framework to study how crystal dislocations influence the functional properties of materials, based on the idea of a quantized dislocation, namely a 'dislon'. In contrast to previous work on dislons which focused on exotic phenomenology, here we focus on their theoretical structure and computational power. We first provide a pedagogical introduction that explains the necessity and benefits of taking the dislon approach and why the dislon Hamiltonian takes its current form. Then, we study the electron–dislocation and phonon–dislocation scattering problems using the dislon formalism. Both the effective electron and phonon theories aremore » derived, from which the role of dislocations on electronic and phononic transport properties is computed. Compared with traditional dislocation scattering studies, which are intrinsically single-particle, low-order perturbation and classical quenched defect in nature, the dislon theory not only allows easy incorporation of quantum many-body effects such as electron correlation, electron–phonon interaction, and higher-order scattering events, but also allows proper consideration of the dislocation's long-range strain field and dynamic aspects on equal footing for arbitrary types of straight-line dislocations. This means that instead of developing individual models for specific dislocation scattering problems, the dislon theory allows for the calculation of electronic structure and electrical transport, thermal transport, optical and superconducting properties, etc, under one unified theory. Furthermore, the dislon theory has another advantage over empirical models in that it requires no fitting parameters. The dislon theory could serve as a major computational tool to understand the role of dislocations on multiple materials' functional properties at an unprecedented level of clarity, and may have wide applications in dislocated energy materials.« less
Sedrakyan, Art; Normand, Sharon-Lise T; Dabic, Stefan; Jacobs, Samantha; Graves, Stephen; Marinac-Dabic, Danica
2011-11-29
To determine comparative safety and effectiveness of combinations of bearing surfaces of hip implants. Systematic review of clinical trials, observational studies, and registries. Medline, Embase, Cochrane Controlled Trials Register, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the United States Food and Drug Administration. Criteria for inclusion were comparative studies in adults reporting information for various combinations of bearings (such as metal on metal and ceramic on ceramic). Data search, abstraction, and analyses were independently performed and confirmed by at least two authors. Qualitative data syntheses were performed. There were 3139 patients and 3404 hips enrolled in 18 comparative studies and over 830 000 operations in national registries. The mean age range in the trials was 42-71, and 26-88% were women. Disease specific functional outcomes and general quality of life scores were no different or they favoured patients receiving metal on polyethylene rather than metal on metal in the trials. While one clinical study reported fewer dislocations associated with metal on metal implants, in the three largest national registries there was evidence of higher rates of implant revision associated with metal on metal implants compared with metal on polyethylene. One trial reported fewer revisions with ceramic on ceramic compared with metal on polyethylene implants, but data from national registries did not support this finding. There is limited evidence regarding comparative effectiveness of various hip implant bearings. Results do not indicate any advantage for metal on metal or ceramic on ceramic implants compared with traditional metal on polyethylene or ceramic on polyethylene bearings.
[Orthopedic management of spina bifida].
Biedermann, R
2014-07-01
Spina bifida is associated with congenital deformities, such as kyphosis, spinal malformations, teratological hip dislocations, clubfeet, vertical talus and also with acquired deformities due to muscle imbalance and impaired biomechanics. The degree of the acquired deformities and the mobility of the patient depend on the level of the spinal lesion. Neurological symptoms are mostly asymmetric and there is an inconsistent correlation between the anatomical level of the lesion and muscle function. Deficits of sensation are usually one to two levels lower than the motor level. An exact neurological diagnosis should not be made before the second or third year of life and an early prognosis about walking ability should be avoided. The level L3 and therefore function of the quadriceps is a functional milestone after which modified independent ambulation with the use of ankle foot orthoses (AFO) and crutches is possible. The basic principle is to support verticalization and gait even when loss of ambulation is later expected. It is also important to support and maintain sitting ability for high lesions, if necessary with correction of the spinal deformity. Findings in gait analysis have shifted the focus of treatment from radiological criteria to functional improvement, thus maintenance of the flexibility of the hip is the main goal of hip surgery. Reduction of the hip often leads to stiffness and has a high redislocation rate. Clubfoot deformities should be treated early and foot arthrodesis and stiffness have to be avoided. Another focus is the prevention of joint contracture by early prophylactic treatment. The purpose of management is to maximize the functional potential of the child. Subjective well-being, absence of pain, mobility and socialization are the main goals. This does not necessarily imply ambulation; nevertheless, verticalization and associated orthotic management is one major objective of the orthopedic management of spina bifida.
Cadossi, Matteo; Garcia, Flávio Luís; Sambri, Andrea; Andreoli, Isabella; Dallari, Dante; Pignatti, Giovanni
2017-01-01
Inadequate acetabular bone stock is a major issue in total hip arthroplasty, and several treatment options are available. Stemmed cups have been used in this scenario with variable results. A novel modular polyaxial uncemented iliac screw cup (HERM-BS-Sansone cup-Citieffe s.r.l., Calderara di Reno, Bologna, Italy) has been recently introduced to overcome the drawbacks of stemmed cups. In this retrospective study, we report the results of this cup in patients with large acetabular bone defects at 2- to 7-year follow-up. We evaluated a consecutive series of 121 hips (118 revisions and 3 complex primary arthroplasties) treated with this novel cup at a mean follow-up of 46 months. Kaplan-Meier survival analysis was performed with implant revision for any reason as a primary end point. Further survival analysis was performed excluding septic failures. Clinical outcome was assessed with the Harris Hip Score. There had been 7 reoperations: 1 for aseptic loosening, 5 for deep infection, and 1 for recurrent dislocation. In 5 cases, the cup was removed; estimated survival rate at 5-year follow-up with implant removal for any reason was 95.6% (95% confidence interval = 91-99), and 98.3% (95% CI = 96-100) excluding those failed for infection. Mean Harris Hip Score at latest follow-up was 77 points (range, 44-95; standard deviation = 11.9). The present findings show the short-term efficacy of the iliac screw cup with respect to implant survival. A longer follow-up and a larger number of patients are necessary to confirm the encouraging preliminary results. Copyright © 2016 Elsevier Inc. All rights reserved.
Analysis of the Temperature and Strain-Rate Dependences of Strain Hardening
NASA Astrophysics Data System (ADS)
Kreyca, Johannes; Kozeschnik, Ernst
2018-01-01
A classical constitutive modeling-based Ansatz for the impact of thermal activation on the stress-strain response of metallic materials is compared with the state parameter-based Kocks-Mecking model. The predicted functional dependencies suggest that, in the first approach, only the dislocation storage mechanism is a thermally activated process, whereas, in the second approach, only the mechanism of dynamic recovery is. In contradiction to each of these individual approaches, our analysis and comparison with experimental evidence shows that thermal activation contributes both to dislocation generation and annihilation.
3D printing technology used in severe hip deformity.
Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui
2017-09-01
This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P<0.05). Based on these results, we suggest that the 3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.
Dynamic phases, pinning, and pattern formation for driven dislocation assemblies
Zhou, Caizhi; Reichhardt, Charles; Olson Reichhardt, Cynthia J.; ...
2015-01-23
We examine driven dislocation assemblies and show that they can exhibit a set of dynamical phases remarkably similar to those of driven systems with quenched disorder such as vortices in superconductors, magnetic domain walls, and charge density wave materials. These phases include pinned-jammed, fluctuating, and dynamically ordered states, and each produces distinct dislocation patterns as well as specific features in the noise fluctuations and transport properties. Lastly, our work suggests that many of the results established for systems with quenched disorder undergoing plastic depinning transitions can be applied to dislocation systems, providing a new approach for understanding pattern formation andmore » dynamics in these systems.« less
Electronic and optical properties of GaN/AlN quantum dots with adjacent threading dislocations
NASA Astrophysics Data System (ADS)
Ye, Han; Lu, Peng-Fei; Yu, Zhong-Yuan; Yao, Wen-Jie; Chen, Zhi-Hui; Jia, Bo-Yong; Liu, Yu-Min
2010-04-01
We present a theory to simulate a coherent GaN QD with an adjacent pure edge threading dislocation by using a finite element method. The piezoelectric effects and the strain modified band edges are investigated in the framework of multi-band k · p theory to calculate the electron and the heavy hole energy levels. The linear optical absorption coefficients corresponding to the interband ground state transition are obtained via the density matrix approach and perturbation expansion method. The results indicate that the strain distribution of the threading dislocation affects the electronic structure. Moreover, the ground state transition behaviour is also influenced by the position of the adjacent threading dislocation.
Nonperturbative Quantum Nature of the Dislocation–Phonon Interaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Mingda; Ding, Zhiwei; Meng, Qingping
Despite the long history of dislocation–phonon interaction studies, there are many problems that have not been fully resolved during this development. These include an incompatibility between a perturbative approach and the long-range nature of a dislocation, the relation between static and dynamic scattering, and their capability of dealing with thermal transport phenomena for bulk material only. Here in this paper, by utilizing a fully quantized dislocation field, which we called a “dislon”, a phonon interacting with a dislocation is renormalized as a quasi-phonon, with shifted quasi-phonon energy, and accompanied by a finite quasi-phonon lifetime, which are reducible to classical results.more » A series of outstanding legacy issues including those above can be directly explained within this unified phonon renormalization approach. For instance, a renormalized phonon naturally resolves the decade-long debate between dynamic and static dislocation–phonon scattering approaches, as two limiting cases. In particular, at nanoscale, both the dynamic and static approaches break down, while the present renormalization approach remains valid by capturing the size effect, showing good agreement with lattice dynamics simulations.« less
Nonperturbative Quantum Nature of the Dislocation–Phonon Interaction
Li, Mingda; Ding, Zhiwei; Meng, Qingping; ...
2017-01-31
Despite the long history of dislocation–phonon interaction studies, there are many problems that have not been fully resolved during this development. These include an incompatibility between a perturbative approach and the long-range nature of a dislocation, the relation between static and dynamic scattering, and their capability of dealing with thermal transport phenomena for bulk material only. Here in this paper, by utilizing a fully quantized dislocation field, which we called a “dislon”, a phonon interacting with a dislocation is renormalized as a quasi-phonon, with shifted quasi-phonon energy, and accompanied by a finite quasi-phonon lifetime, which are reducible to classical results.more » A series of outstanding legacy issues including those above can be directly explained within this unified phonon renormalization approach. For instance, a renormalized phonon naturally resolves the decade-long debate between dynamic and static dislocation–phonon scattering approaches, as two limiting cases. In particular, at nanoscale, both the dynamic and static approaches break down, while the present renormalization approach remains valid by capturing the size effect, showing good agreement with lattice dynamics simulations.« less
Hirotani, Hayato
2009-03-01
In addition to articles written by Prof. Dr. M. Matsuoka previously reported in Part 2, books written by him are presented as Part 3 of the articles regarding his academic achievements. He published four text books, including the first textbook of orthopaedic surgery in Japan that was written by a Japanese doctor and a monograph on the x-ray atlas of congenital dislocation of the hip that was written in German and published in Germany. He was also invited to submit articles to three books as co-author. Furthermore, his five educational lectures given to the public were published in two books.
Femoroacetabular Impingement Surgery Is on the Rise-But What Is the Next Step?
Reiman, Michael P; Thorborg, Kristian; Hölmich, Per
2016-06-01
Surgery for femoroacetabular impingement (FAI) has been advocated for correction of cam and pincer hip joint morphology. Surgery for FAI was first pioneered by Myers et al, who surgically treated FAI by open dislocation. Arthroscopy was then introduced in 2005 by Sampson. Arthroscopy has continued to develop since then, with the intent of providing pain relief and improving function in patients with FAI. This Viewpoint discusses the escalating popularity of FAI surgery, the widespread acceptance of this relatively new surgical procedure, and next steps for determination of who benefits from this treatment. J Orthop Sports Phys Ther 2016;46(6):406-408. doi:10.2519/jospt.2016.0605.
Creep of quartz by dislocation and grain boundary processes
NASA Astrophysics Data System (ADS)
Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.
2015-12-01
Wet polycrystalline quartz aggregates deformed at temperatures T of 600°-900°C and strain rates of 10-4-10-6 s-1 at a confining pressure Pc of 1.5 GPa exhibit plasticity at low T, governed by dislocation glide and limited recovery, and grain size-sensitive creep at high T, governed by diffusion and sliding at grain boundaries. Quartz aggregates were HIP-synthesized, subjecting natural milky quartz powder to T=900°C and Pc=1.5 GPa, and grain sizes (2 to 25 mm) were varied by annealing at these conditions for up to 10 days. Infrared absorption spectra exhibit a broad OH band at 3400 cm-1 due to molecular water inclusions with a calculated OH content (~4000 ppm, H/106Si) that is unchanged by deformation. Rate-stepping experiments reveal different stress-strain rate functions at different temperatures and grain sizes, which correspond to differing stress-temperature sensitivities. At 600-700°C and grain sizes of 5-10 mm, flow law parameters compare favorably with those for basal plasticity and dislocation creep of wet quartzites (effective stress exponents n of 3 to 6 and activation enthalpy H* ~150 kJ/mol). Deformed samples show undulatory extinction, limited recrystallization, and c-axis maxima parallel to the shortening direction. Similarly fine-grained samples deformed at 800°-900°C exhibit flow parameters n=1.3-2.0 and H*=135-200 kJ/mol corresponding to grain size-sensitive Newtonian creep. Deformed samples show some undulatory extinction and grain sizes change by recrystallization; however, grain boundary deformation processes are indicated by the low value of n. Our experimental results for grain size-sensitive creep can be compared with models of grain boundary diffusion and grain boundary sliding using measured rates of silicon grain boundary diffusion. While many quartz mylonites show microstructural and textural evidence for dislocation creep, results for grain size-sensitive creep may apply to very fine-grained (<10 mm) quartz mylonites.
Knee joint effusion following ipsilateral hip surgery.
Christodoulou, A G; Givissis, P; Antonarakos, P D; Petsatodis, G E; Hatzokos, I; Pournaras, J D
2010-12-01
To correlate patellar reflex inhibition with sympathetic knee joint effusion. 65 women and 40 men aged 45 to 75 (mean, 65) years underwent hip surgery. The surgery entailed dynamic hip screw fixation using the lateral approach with reflection of the vastus lateralis for pertrochantric fractures (n = 49), and hip hemiarthroplasty or total hip replacement using the Watson-Jones approach (n = 38) or hip hemiarthroplasty using the posterior approach (n = 18) for subcapital femoral fractures (n = 28) or osteoarthritis (n = 28). Knee joint effusion, patellar reflex, and thigh circumference were assessed in both legs before and after surgery (at day 0.5, 2, 7, 14, 30, and 45). Time-sequence plots were used for chronological analysis, and correlation between patellar reflex inhibition and knee joint effusion was tested. In the time-sequence plot, the peak frequency of patellar reflex inhibition (on day 0.5) preceded that of the knee joint effusion and the thigh circumference increase (on day 2). Patellar reflex inhibition correlated positively with the knee joint effusion (r = 0.843, p = 0.035). These 2 factors correlated significantly for all 3 surgical approaches (p < 0.0005). All 3 approaches were associated with patellar reflex inhibition on day 0.5 (p = 0.033) and knee joint effusion on day 2 (p = 0.051). Surgical trauma of the thigh may cause patellar reflex inhibition and subsequently knee joint effusion.
Ehlers–Danlos Syndrome—Hypermobility Type: A Much Neglected Multisystemic Disorder
Gazit, Yael; Jacob, Giris; Grahame, Rodney
2016-01-01
Ehlers–Danlos syndrome (EDS)—hypermobility type (HT) is considered to be the most common subtype of EDS and the least severe one; EDS-HT is considered to be identical to the joint hypermobility syndrome and manifests with musculoskeletal complaints, joint instability, and soft tissue overuse injury. Musculoskeletal complaints manifest with joint pain of non-inflammatory origin and/or spinal pain. Joint instability leads to dislocation or subluxation and involves peripheral joints as well as central joints, including the temporomandibular joints, sacroiliac joints, and hip joints. Soft tissue overuse injury may lead to tendonitis and bursitis without joint inflammation in most cases. Ehlers–Danlos syndrome-HT carries a high potential for disability due to recurrent dislocations and subluxations and chronic pain. Throughout the years, extra-articular manifestations have been described, including cardiovascular, autonomic nervous system, gastrointestinal, hematologic, ocular, gynecologic, neurologic, and psychiatric manifestations, emphasizing the multisystemic nature of EDS-HT. Unfortunately, EDS-HT is under-recognized and inadequately managed, leading to neglect of these patients, which may lead to severe disability that almost certainly could have been avoided. In this review article we will describe the known manifestations of the extra-articular systems. PMID:27824552
Dislocated Workers and Midcareer Retraining in Other Industrial Nations.
ERIC Educational Resources Information Center
Bendick, Marc, Jr.
Market-oriented industrial nations other than the United States have experienced rapid structural changes in their economies and reemployment problems among dislocated midcareer workers. The Swedish active labor market approach is a socialized one. This system has been criticized for excessive reliance on microeconomic labor market programs to…
Identification of Potential Therapeutic Mechanisms for HIP1 Inhibition in Breast Cancer
2006-05-01
repressing transcription when knocked down using a silencing RNA approach and activating tran- scription when overexpressed. We have also identified a...HIP1, huntingtin interacting protein 1; PSA, prostate-specific antigen; siRNA, silencing RNA . The online version of this article includes supplemental...We examined whether endogenous HIP1 was also required to sustain AR transcriptional activity by taking a silencing RNA (siRNA) approach to knockdown
Sims, Kevin; Spina, Andreo
2009-12-01
To present an evidence-informed approach to the nonoperative management of a first-time, traumatic anterior shoulder dislocation. A 30-year-old mixed martial arts athlete, with no prior shoulder injuries, presented one day following a first-time, traumatic anterior shoulder dislocation. An eight-week, individualized, intensive, nonoperative rehabilitation program was immediately begun upon presentation. Management consisted of immobilization of the shoulder in external rotation and a progressive rehabilitation program aimed at restoring range of motion, strength of the dynamic stabilizers, and proprioception of the shoulder. Eight weeks post-dislocation the patient had regained full range of motion and strength compared to the unaffected limb and apprehension and relocation tests for instability were negative. This case illustrates successful management of a first-time, traumatic, anterior shoulder dislocation using immobilization in external rotation combined with an intensive rehabilitation program.
Sims, Kevin; Spina, Andreo
2009-01-01
Objective: To present an evidence-informed approach to the nonoperative management of a first-time, traumatic anterior shoulder dislocation. Clinical Features: A 30-year-old mixed martial arts athlete, with no prior shoulder injuries, presented one day following a first-time, traumatic anterior shoulder dislocation. An eight-week, individualized, intensive, nonoperative rehabilitation program was immediately begun upon presentation. Intervention and Outcome: Management consisted of immobilization of the shoulder in external rotation and a progressive rehabilitation program aimed at restoring range of motion, strength of the dynamic stabilizers, and proprioception of the shoulder. Eight weeks post-dislocation the patient had regained full range of motion and strength compared to the unaffected limb and apprehension and relocation tests for instability were negative. Conclusion: This case illustrates successful management of a first-time, traumatic, anterior shoulder dislocation using immobilization in external rotation combined with an intensive rehabilitation program. PMID:20037691
Dislocation dynamics in non-convex domains using finite elements with embedded discontinuities
NASA Astrophysics Data System (ADS)
Romero, Ignacio; Segurado, Javier; LLorca, Javier
2008-04-01
The standard strategy developed by Van der Giessen and Needleman (1995 Modelling Simul. Mater. Sci. Eng. 3 689) to simulate dislocation dynamics in two-dimensional finite domains was modified to account for the effect of dislocations leaving the crystal through a free surface in the case of arbitrary non-convex domains. The new approach incorporates the displacement jumps across the slip segments of the dislocations that have exited the crystal within the finite element analysis carried out to compute the image stresses on the dislocations due to the finite boundaries. This is done in a simple computationally efficient way by embedding the discontinuities in the finite element solution, a strategy often used in the numerical simulation of crack propagation in solids. Two academic examples are presented to validate and demonstrate the extended model and its implementation within a finite element program is detailed in the appendix.
Bernard, J; Beldame, J; Van Driessche, S; Brunel, H; Poirier, T; Guiffault, P; Matsoukis, J; Billuart, F
2017-11-01
Minimally invasive total hip arthroplasty (THA) is presumed to provide functional and clinical benefits, whereas in fact the literature reveals that gait and posturographic parameters following THA do not recover values found in the general population. There is a significant disturbance of postural sway in THA patients, regardless of the surgical approach, although with some differences between approaches compared to controls: the anterior and anterolateral minimally invasive approaches seem to be more disruptive of postural parameters than the posterior approach. Electromyographic (EMG) study of the hip muscles involved in surgery [gluteus maximus (GMax), gluteus medius (GMed), tensor fasciae latae (TFL), and sartorius (S)] could shed light, the relevant literature involves discordant methodologies. We developed a methodology to assess EMG activity during maximal voluntary contraction (MVC) of the GMax, GMed, TFL and sartorius muscles as a reference for normalization. A prospective study aimed to assess whether hip joint positioning and the learning curve on an MVC test affect the EMG signal during a maximal voluntary contraction. Hip positioning and the learning curve on an MVC test affect EMG signal during MVC of GMax, GMed, TFL and S. Thirty young asymptomatic subjects participated in the study. Each performed 8 hip muscle MVCs in various joint positions recorded with surface EMG sensors. Each MVC was performed 3 times in 1 week, with the same schedule every day, controlling for activity levels in the preceding 24h. EMG activity during MVC was expressed as a ratio of EMG activity during unipedal stance. Non-parametric tests were applied. Statistical analysis showed no difference according to hip position for abductors or flexors in assessing EMG signal during MVC over the 3 sessions. Hip abductors showed no difference between abduction in lateral decubitus with hip straight versus hip flexed: GMax (19.8±13.7 vs. 14.5±7.8, P=0.78), GMed (13.4±9.0 vs. 9.9±6.6, P=0.21) and TFL (69.5±61.7 vs. 65.9±51.3, P=0.50). Flexors showed no difference between hip flexion/abduction/lateral rotation performed in supine or sitting position: TFL (70.6±45.9 vs. 61.6±45.8, P=0.22) and S (101.1±67.9 vs. 72.6±44.6, P=0.21). The most effective tests to assess EMG signal during MVC were for the hip abductors: hip abduction performed in lateral decubitus (36.7% for GMax, 76.7% for GMed), and for hip flexors: hip flexion/abduction/lateral rotation performed in supine decubitus (50% for TFL, 76.7% for S). The study hypothesis was not confirmed, since hip joint positioning and the learning curve on an MVC test did not affect EMG signal during MVC of GMax, GMed, TFL and S muscles. Therefore, a single session and one specific test is enough to assess MVC in hip abductors (abduction in lateral decubitus) and flexors (hip flexion/abduction/lateral rotation in supine position). This method could be applied to assess muscle function after THA, and particularly to compare different approaches. III, case-matched study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Theory of electron-phonon-dislon interacting system—toward a quantized theory of dislocations
NASA Astrophysics Data System (ADS)
Li, Mingda; Tsurimaki, Yoichiro; Meng, Qingping; Andrejevic, Nina; Zhu, Yimei; Mahan, Gerald D.; Chen, Gang
2018-02-01
We provide a comprehensive theoretical framework to study how crystal dislocations influence the functional properties of materials, based on the idea of a quantized dislocation, namely a ‘dislon’. In contrast to previous work on dislons which focused on exotic phenomenology, here we focus on their theoretical structure and computational power. We first provide a pedagogical introduction that explains the necessity and benefits of taking the dislon approach and why the dislon Hamiltonian takes its current form. Then, we study the electron-dislocation and phonon-dislocation scattering problems using the dislon formalism. Both the effective electron and phonon theories are derived, from which the role of dislocations on electronic and phononic transport properties is computed. Compared with traditional dislocation scattering studies, which are intrinsically single-particle, low-order perturbation and classical quenched defect in nature, the dislon theory not only allows easy incorporation of quantum many-body effects such as electron correlation, electron-phonon interaction, and higher-order scattering events, but also allows proper consideration of the dislocation’s long-range strain field and dynamic aspects on equal footing for arbitrary types of straight-line dislocations. This means that instead of developing individual models for specific dislocation scattering problems, the dislon theory allows for the calculation of electronic structure and electrical transport, thermal transport, optical and superconducting properties, etc, under one unified theory. Furthermore, the dislon theory has another advantage over empirical models in that it requires no fitting parameters. The dislon theory could serve as a major computational tool to understand the role of dislocations on multiple materials’ functional properties at an unprecedented level of clarity, and may have wide applications in dislocated energy materials.
2011-01-01
Background Virtually all the articles in literature addressed only a specific type of dislocation. The aim of this review was to project a comprehensive understanding of the pathologic processes and management of all types of dislodgement of the head of the mandibular condyle from its normal position in the glenoid fossa. In addition, a new classification of temporomandibular joint dislocation was also proposed. Method and materials A thorough computer literature search was done using the Medline, Cochrane library and Embase database. Key words like temporo-mandibular joint dislocation were used for the search. Additional manual search was done by going through published home-based and foreign articles. Case reports/series, and original articles that documented the type of dislocation, number of cases treated in the series and original articles. Treatment done and outcome of treatment were included in the study. Result A total of 128 articles were reviewed out which 79 were found relevant. Of these, 26 were case reports, 17 were case series and 36 were original articles. 79 cases were acute dislocations, 35 cases were chronic protracted TMJ dislocations and 311 cases were chronic recurrent TMJ dislocations. Etiology was predominantly trauma in 60% of cases and other causes contributed about 40%. Of all the cases reviewed, only 4 were unilateral dislocation. Various treatment modalities are outlined in this report as indicated for each type of dislocation. Conclusion The more complex and invasive method of treatment may not necessarily offer the best option and outcome of treatment, therefore conservative approaches should be exhausted and utilized appropriately before adopting the more invasive surgical techniques. PMID:21676208
Akinbami, Babatunde O
2011-06-15
Virtually all the articles in literature addressed only a specific type of dislocation. The aim of this review was to project a comprehensive understanding of the pathologic processes and management of all types of dislodgement of the head of the mandibular condyle from its normal position in the glenoid fossa. In addition, a new classification of temporomandibular joint dislocation was also proposed. A thorough computer literature search was done using the Medline, Cochrane library and Embase database. Key words like temporo-mandibular joint dislocation were used for the search. Additional manual search was done by going through published home-based and foreign articles. Case reports/series, and original articles that documented the type of dislocation, number of cases treated in the series and original articles. Treatment done and outcome of treatment were included in the study. A total of 128 articles were reviewed out which 79 were found relevant. Of these, 26 were case reports, 17 were case series and 36 were original articles. 79 cases were acute dislocations, 35 cases were chronic protracted TMJ dislocations and 311 cases were chronic recurrent TMJ dislocations. Etiology was predominantly trauma in 60% of cases and other causes contributed about 40%. Of all the cases reviewed, only 4 were unilateral dislocation. Various treatment modalities are outlined in this report as indicated for each type of dislocation. The more complex and invasive method of treatment may not necessarily offer the best option and outcome of treatment, therefore conservative approaches should be exhausted and utilized appropriately before adopting the more invasive surgical techniques.
NASA Astrophysics Data System (ADS)
Silbermann, C. B.; Ihlemann, J.
2016-03-01
Continuum Dislocation Theory (CDT) relates gradients of plastic deformation in crystals with the presence of geometrically necessary dislocations. Therefore, the dislocation tensor is introduced as an additional thermodynamic state variable which reflects tensorial properties of dislocation ensembles. Moreover, the CDT captures both the strain energy from the macroscopic deformation of the crystal and the elastic energy of the dislocation network, as well as the dissipation of energy due to dislocation motion. The present contribution deals with the geometrically linear CDT. More precise, the focus is on the role of dislocation kinematics for single and multi-slip and its consequences on the field equations. Thereby, the number of active slip systems plays a crucial role since it restricts the degrees of freedom of plastic deformation. Special attention is put on the definition of proper, well-defined invariants of the dislocation tensor in order to avoid any spurious dependence of the resulting field equations on the coordinate system. It is shown how a slip system based approach can be in accordance with the tensor nature of the involved quantities. At first, only dislocation glide in one active slip system of the crystal is allowed. Then, the special case of two orthogonal (interacting) slip systems is considered and the governing field equations are presented. In addition, the structure and symmetry of the backstress tensor is investigated from the viewpoint of thermodynamical consistency. The results will again be used in order to facilitate the set of field equations and to prepare for a robust numerical implementation.
Samson, Deepak; Ng, Chye Yew; Power, Dominic
2016-01-01
Traumatic knee dislocation is a complex ligamentous injury that may be associated with simultaneous vascular and neurological injury. Although orthopaedic surgeons may consider CPN exploration at the time of ligament reconstruction, there is no standardised approach to the management of this complex and debilitating complication. This review focusses on published evidence of the outcomes of common peroneal nerve (CPN) injuries associated with knee dislocation, and proposes an algorithm for the management. Cite this article: Deepak Samson, Chye Yew Ng, Dominic Power. An evidence-based algorithm for the management of common peroneal nerve injury associated with traumatic knee dislocation. EFORT Open Rev 2016;1:362-367. DOI: 10.1302/2058-5241.160012. PMID:28461914
Avalanches and plastic flow in crystal plasticity: an overview
NASA Astrophysics Data System (ADS)
Papanikolaou, Stefanos; Cui, Yinan; Ghoniem, Nasr
2018-01-01
Crystal plasticity is mediated through dislocations, which form knotted configurations in a complex energy landscape. Once they disentangle and move, they may also be impeded by permanent obstacles with finite energy barriers or frustrating long-range interactions. The outcome of such complexity is the emergence of dislocation avalanches as the basic mechanism of plastic flow in solids at the nanoscale. While the deformation behavior of bulk materials appears smooth, a predictive model should clearly be based upon the character of these dislocation avalanches and their associated strain bursts. We provide here a comprehensive overview of experimental observations, theoretical models and computational approaches that have been developed to unravel the multiple aspects of dislocation avalanche physics and the phenomena leading to strain bursts in crystal plasticity.
Gradual Reduction of Chronic Fracture Dislocation of the Ankle Using Ilizarov/Taylor Spatial Frame
Deland, Jonathan T.; Rozbruch, S. Robert
2010-01-01
With the advances in trauma care, chronic fracture dislocation of the ankle is not a condition commonly seen in modern clinical practice. When encountered, it can be difficult to preserve the ankle joint. We present a case of a 65-year-old female, with a chronic fracture dislocation of the ankle. The ankle joint was subluxated with posterior translation of the talus, displacement of the posterior malleolus fragment, and a distal fibula fracture. A minimally traumatic approach was devised to treat this complex fracture dislocation which included gradual reduction of the ankle with a Taylor spatial frame, followed by stabilization with internal fixation and removal of the frame. Bony union and restoration of the ankle joint congruency was achieved. PMID:22294963
Management of acetabular fractures with modified posterior approach to spare external hip rotators.
Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay
2014-04-01
In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Samolyuk, G. D.; Osetsky, Y. N.; Stoller, R. E.
2013-01-01
Several transition metals were examined to evaluate their potential for improving the ductility of tungsten. The dislocation core structure and Peierls stress and barrier of 1/2<111> screw dislocations in binary tungsten-transition metal alloys (W1-xTMx) were investigated using density functional theory calculations. The periodic quadrupole approach was applied to model the structure of the 1/2<111> dislocation. Alloying with transition metals was modeled using the virtual crystal approximation and the applicability of this approach was assessed by calculating the equilibrium lattice parameter and elastic constants of the tungsten alloys. Reasonable agreement was obtained with experimental data and with results obtained from the conventional supercell approach. Increasing the concentration of a transition metal from the VIIIA group, i.e. the elements in columns headed by Fe, Co and Ni, leads to reduction of the C‧ elastic constant and increase of the elastic anisotropy A = C44/C‧. Alloying W with a group VIIIA transition metal changes the structure of the dislocation core from symmetric to asymmetric, similarly to results obtained for W1-xRex alloys in the earlier work of Romaner et al (2010 Phys. Rev. Lett. 104 195503). In addition to a change in the core symmetry, the values of the Peierls stress and barrier are reduced. The latter effect could lead to increased ductility in a tungsten-based alloy. Our results demonstrate that alloying with any of the transition metals from the VIIIA group should have a similar effect to alloying with Re.
NASA Astrophysics Data System (ADS)
Azadi, Amir; Grason, Gregory M.
2014-03-01
Predicting the ground state ordering of curved crystals remains an unsolved, century-old challenge, beginning with the classic Thomson problem to more recent studies of particle-coated droplets. We study the structural features and underlying principles of multi-dislocation ground states of a crystalline cap adhered to a spherical substrate. In the continuum limit, vanishing lattice spacing, a --> 0 , dislocations proliferate and we show that ground states approach a characteristic sequence of patterns of n-fold radial grain boundary ``scars,'' extending from the boundary and terminating in the bulk. A combination of numerical and asymptotic analysis reveals that energetic hierarchy gives rise to a structural hierarchy, whereby the number of dislocation and scars diverge as a --> 0 while the scar length and number of dislocations per scar become remarkably independent of lattice spacing. We show the that structural hierarchy remains intact when n-fold symmetry becomes unstable to polydispersed forked-scar morphologies. We expect this analysis to resolve previously open questions about the optimal symmetries of dislocation patterns in Thomson-like problems, both with and without excess 5-fold defects.
Peters, Rinne M; van Beers, Loes W A H; van Steenbergen, Liza N; Wolkenfelt, Julius; Ettema, Harmen B; Ten Have, Bas L E F; Rijk, Paul C; Stevens, Martin; Bulstra, Sjoerd K; Poolman, Rudolf W; Zijlstra, Wierd P
2018-06-01
Patient-reported outcome measures (PROMs) are used to evaluate the outcome of total hip arthroplasty (THA). We determined the effect of surgical approach on PROMs after primary THA. All primary THAs, with registered preoperative and 3 months postoperative PROMs were selected from the Dutch Arthroplasty Register. Based on surgical approach, 4 groups were discerned: (direct) anterior, anterolateral, direct lateral, and posterolateral approaches. The following PROMs were recorded: Hip disability and Osteoarthritis Outcome Score Physical function Short form (HOOS-PS); Oxford Hip Score; EQ-5D index score; EQ-5D thermometer; and Numeric Rating Scale measuring pain, both active and in rest. The difference between preoperative and postoperative scores was calculated (delta-PROM) and used as primary outcome measure. Multivariable linear regression analysis was performed for comparisons. Cohen's d was calculated as measure of effect size. All examined 4 approaches resulted in a significant increase of PROMs after primary THA in the Netherlands (n = 12,274). The anterior and posterolateral approaches were associated with significantly more improvement in HOOS-PS scores compared with the anterolateral and direct lateral approaches. Furthermore, the posterolateral and anterior approaches showed greater improvement on Numeric Rating Scale pain scores compared with the anterolateral approach. No relevant differences in delta-PROM were seen between the anterior and posterolateral surgical approaches. Anterior and posterolateral surgical approaches showed more improvement in self-reported physical functioning (HOOS-PS) compared with anterolateral and direct lateral approaches in patients receiving a primary THA. However, clinical differences were only small. Copyright © 2018 Elsevier Inc. All rights reserved.
Kanna, Rishi M; Shetty, Ajoy P; Rajasekaran, S
2018-06-01
Surgical reduction of uni and bi-facetal dislocations of the cervical spine (AO type C injuries) can be performed by posterior, anterior or combined approaches. Ease of access, low infection rates and less risks of neurological worsening has popularized anterior approach. However, the reduction of locked cervical facets can be intricate through anterior approach. We analyzed the safety, efficacy and outcomes at a minimum 1 year, of a novel anterior reduction technique for consecutively treated cervical facet dislocations. Patients with single level traumatic sub-axial cervical dislocation (n = 39) treated by this modified anterior technique were studied. The technique involved standard Smith-Robinson approach, discectomy beyond PLL, use of inter-laminar distracter to distract while Caspar pins were used as "joysticks" (either flexion-extension or lateral rotation moments are provided), to reduce the sub-luxed facets. Among 51 patients with cervical type C injury treated during the study period, 4 patients who had spontaneous reduction and 8 treated by planned global fusion were excluded. 39 patients of mean age 49.9 years were studied. The levels of injury included (C3-4 = 2, C4-5 = 5, C5-6 = 20, C6-7 = 12). 18 were bi-facetal and 21 were uni-facetal dislocation. One facet was fractured in 17 and both in 5 patients. 30% (n = 13) had a concomitant disc prolapse. The neurological status was as follows: 9 ASIA A, 9 ASIA C, 13 ASIA D and 8 ASIA E. All the patients were successfully reduced by this technique and fixed with anterior locking cervical locking plates. No supplemental posterior surgery was performed. 22 patients with incomplete deficit showed recovery. The mean follow-up was 14.3 months and there was no implant failure except one patient who had partial loss of the reduction. Patients with traumatic sub-axial cervical dislocation (AO type C injuries) can be safely and effectively reduced by this technique. Other advantages include minimal blood loss, less risks of infection, shorted fusion zone, good fusion rate and neurological recovery.
Putzer, David; Haselbacher, Matthias; Hörmann, Romed; Klima, Günter; Nogler, Michael
2017-12-01
Surgical approaches through smaller incisions reveal less of the underlying anatomy, and therefore, detailed knowledge of the local anatomy and its variations is important in minimally invasive surgery. The aim of this study was to determine the location, extension, and histomorphology of the deep layer of the iliotibial band during minimally invasive hip surgery using the direct anterior approach (DAA). The morphology of the iliotibial tract was determined in this cadaver study on 40 hips with reference to the anterior superior iliac spine and the tibia. The deep layer of the tractus iliotibialis was exposed up to the hip-joint capsule and length and width measurements taken. Sections of the profound iliotibial tract were removed from the hips and the thickness of the sections was determined microscopically after staining. The superficial tractus iliotibialis had a length of 50.1 (SD 3.8) cm, while tensor fasciae latae total length was 18 (SD 2) cm [unattached 15 (SD 2.5) cm]. Length and width of the deep layer of the tractus iliotibialis were 10.4 (SD 1.3) × 3.3 (SD 0.6) cm. The deep iliotibial band always extended from the distal part of the tensor fascia latae (TFL) muscle to the lateral part of the hip capsule (mean maximum thickness 584 μm). Tractus iliotibialis deep layer morphology did not correlate to other measurements taken (body length, thigh length, and TFL length). The length of the deep layer is dependent on the TFL, since the profound part of the iliotibial band reaches from the TFL to the hip-joint capsule. The deep layer covers the hip-joint capsule, rectus, and lateral vastus muscles in the DAA interval. To access the precapsular fat pad and the hip-joint capsule, the deep layer has to be split in all approaches that use the direct anterior interval.
High Risk of Readmission in Octogenarians Undergoing Primary Hip Arthroplasty.
Malkani, Arthur L; Dilworth, Brian; Ong, Kevin; Baykal, Doruk; Lau, Edmund; Mackin, Theresa N; Lee, Gwo-Chin
2017-12-01
As life expectancy increases, more elderly patients with end-stage hip arthritis are electing to undergo primary THA. Octogenarians undergoing THA have more comorbidities than younger patients, but this is not reflected in risk adjustment models for bundled care programs. The burden of care associated with THA in octogenarians has not been well characterized, and doing so may help these value-based programs make adjustments so that this vulnerable patient population does not risk losing access under accountable care models. The purpose of this study was to describe care use, comorbidities, and complications among octogenarians undergoing primary THA. Five percent of the Medicare national administrative claims data was queried to identify patients diagnosed with hip osteoarthritis between January 1, 1998, and December 31, 2013. Patients who underwent primary THA were identified and followed longitudinally during the study period using their unique, encrypted Medicare beneficiary identifiers. We compared risk factors and complications between the octogenarian group versus those aged 65 to 69 years. Multivariate Cox regression was used to evaluate the effect of patient/hospital factors on risk of revision, periprosthetic joint infection, dislocation, venous thromboembolism (VTE), and mortality. Patient factors in the model included age, sex, race, region, socioeconomic status, and health status based on Charlson comorbidity score 12 months before replacement surgery. There were 11,960 THAs in the octogenarians in 1998, which increased to 21,620 in 2013, an 81% increase during this study period. Octogenarians were more likely to have a Charlson score of 3 or higher than those patients aged 65 to 69 years (30% versus 17%, odds ratio [OR] 2.07 [1.98-2.20]; p < 0.001), and they were more likely to have coronary artery disease or congestive heart failure (47% versus 29%, OR 2.16 [2.06-2.26]; p < 0.001). The octogenarian group had a greater risk of dislocation (+12%, p = 0.01), VTE (+14%, p < 0.001), and mortality (+150%, p < 0.001) compared with the younger age cohort. A total of 21% of the octogenarians were readmitted after surgery compared with 12% for patients in the younger group (OR=1.64, 95% confidence interval 1.54-1.75; p < 0.001). Because octogenarians are at increased risk of dislocation, VTE, medical complications, and mortality after THA, value-based care models that penalize hospitals for readmissions and complications may inadvertently result in loss of access to care for this group of patients as a result of the financial makeup of these bundled care models. Value-based care models were developed to improve care and decrease healthcare costs but may have unintended consequences in the octogenarian with higher complication and readmission risks. Financial losses may lead to institutions from withdrawing from the Bundled Payments for Care Improvement program. To try to prevent this from happening to this vulnerable patient population, bundled care programs should evolve and be modified to allow for risk stratification in the overall payment formula to account for increased age and comorbid conditions to ensure continued successful participation in the program among all the stakeholders. Level III, therapeutic study.
Clinical examination and physical assessment of hip joint-related pain in athletes.
Reiman, Michael P; Thorborg, Kristian
2014-11-01
Evidence-based clinical examination and assessment of the athlete with hip joint related pain is complex. It requires a systematic approach to properly differentially diagnose competing potential causes of athletic pain generation. An approach with an initial broad focus (and hence use of highly sensitive tests/measures) that then is followed by utilizing more specific tests/measures to pare down this imprecise differential diagnosis list is suggested. Physical assessment measures are then suggested to discern impairments, activity and participation restrictions for athletes with hip-join related pain, hence guiding the proper treatment approach. 5.
What MRI Findings Predict Failure 10 Years After Surgery for Femoroacetabular Impingement?
Hanke, Markus S; Steppacher, Simon D; Anwander, Helen; Werlen, Stefan; Siebenrock, Klaus A; Tannast, Moritz
2017-04-01
Magnetic resonance arthrogram (MRA) with radial cuts is presently the best available preoperative imaging study to evaluate chondrolabral lesions in the setting of femoroacetabular impingement (FAI). Existing followup studies for surgical treatment of FAI have evaluated predictors of treatment failure based on preoperative clinical examination, intraoperative findings, and conventional radiography. However, to our knowledge, no study has examined whether any preoperative findings on MRA images might be associated with failure of surgical treatment of FAI in the long term. The purposes of this study were (1) to identify the preoperative MRA findings that are associated with conversion to THA, any progression of osteoarthritis, and/or a Harris hip score of < 80 points after acetabuloplasty and/or osteochondroplasty of the femoral head-neck junction through a surgical hip dislocation (SHD) for FAI at a minimum 10-year followup; and (2) identify the age of patients with symptomatic FAI when these secondary degenerative findings were detected on preoperative radial MRAs. We retrospectively studied 121 patients (146 hips) who underwent acetabuloplasty and/or osteochondroplasty of the femoral head-neck junction through SHD for symptomatic anterior FAI between July 2001 and March 2003. We excluded 35 patients (37 hips) with secondary FAI after previous surgery and 11 patients (12 hips) with Legg-Calvé-Perthes disease. All patients underwent preoperative MRA to further specify chondrolabral lesions except in 19 patients (32 hips) including 17 patients (20 hips) who presented with an MRI from an external institution taken with a different protocol, 10 patients with no preoperative MRA because the patients had already been operated on the contralateral side with a similar appearance, and two patients (two hips) refused MRA because of claustrophobia. This resulted in 56 patients (65 hips) with idiopathic FAI and a preoperative MRA. Of those, three patients (three hips) did not have minimal 10-year followup (one patient died; two hips with followup between 5 and 6 years). The remaining patients were evaluated clinically and radiographically at a mean followup of 11 years (range, 10-13 years). Thirteen pathologic radiographic findings on the preoperative MRA were evaluated for an association with the following endpoints using Cox regression analysis: conversion to THA, radiographic evidence of any progression of osteoarthritis, and/or a Harris hip score of < 80. The age of the patient when each degenerative pattern was found on the preoperative MRA was recorded. The following MRI findings were associated with one or more of our predefined failure endpoints: cartilage damage exceeding 60° of the circumference had a hazard ratio (HR) of 4.6 (95% confidence interval [CI], 3.6-5.6; p = 0.003) compared with a damage of less than 60°, presence of an acetabular rim cyst had a HR of 4.1 (95% CI, 3.1-5.2; p = 0.008) compared with hips without these cysts, and presence of a sabertooth osteophyte had a HR of 3.2 (95% CI, 2.3-4.2; p = 0.013) compared with hips without a sabertooth osteophyte. The degenerative pattern associated with the youngest patient age when detected on preoperative MRA was the sabertooth osteophyte (lower quartile 27 years) followed by cartilage damage exceeding 60° of the circumference (28 years) and the presence of an acetabular rim bone cyst (31 years). Preoperative MRAs with radial cuts reveal important findings that may be associated with future failure of surgical treatment for FAI. Most of these factors are not visible on conventional radiographs or standard hip MRIs. Preoperative MRA evaluation is therefore strongly recommended on a routine basis for patients undergoing these procedures. Findings associated with conversion to arthroplasty, radiographic evidence of any progression of osteoarthritis, and/or a Harris hip score of < 80 points should be incorporated into the decision-making process in patients being evaluated for joint-preserving hip surgery. Level III, therapeutic study.
Xu, Yong; Li, Feng; Guan, Hanfeng; Xiong, Wei
2015-01-01
Abstract Posterior atlantoaxial dislocation without odontoid fracture is extremely rare and often results in fatal spinal cord injury. According to the reported literature, all cases presented mild or no neurologic deficit, with no definite relation to upper spinal cord injury. Little is reported about traumatic posterior atlantoaxial dislocation, with incomplete quadriplegia associated with a spinal cord injury. We present a case of posterior atlantoaxial dislocation without associated fracture, but with quadriplegia, and accompanying epidural hematoma and subarachnoid hemorrhage. The patient underwent gentle traction in the neutral position until repeated cranial computed tomography revealed no progression of the epidural hematoma. Thereafter, the atlantoaxial dislocation was reduced by using partial odontoidectomy via a video-assisted transcervical approach and maintained with posterior polyaxial screw-rod constructs and an autograft. Neurological status improved immediately after surgery, and the patient recovered completely after 1 year. Posterior fusion followed by closed reduction is the superior strategy for posterior atlantoaxial dislocation without odontoid fracture, according to literature. But for cases with severe neurological deficit, open reduction may be the safest choice to avoid the lethal complication of overdistraction of the spinal cord. Also, open reduction and posterior srew-rod fixation are safe and convenient strategies in dealing with traumatic posterior atlantoaxial dislocation patients with neurological deficit. PMID:26512572
Computer aided diagnosis and treatment planning for developmental dysplasia of the hip
NASA Astrophysics Data System (ADS)
Li, Bin; Lu, Hongbing; Cai, Wenli; Li, Xiang; Meng, Jie; Liang, Zhengrong
2005-04-01
The developmental dysplasia of the hip (DDH) is a congenital malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Early diagnosis and treatment is important because failure to diagnose and improper treatment can result in significant morbidity. In this paper, we designed and implemented a computer aided system for the diagnosis and treatment planning of this disease. With the design, the patient received CT (computed tomography) or MRI (magnetic resonance imaging) scan first. A mixture-based PV partial-volume algorithm was applied to perform bone segmentation on CT image, followed by three-dimensional (3D) reconstruction and display of the segmented image, demonstrating the special relationship between the acetabulum and femurs for visual judgment. Several standard procedures, such as Salter procedure, Pemberton procedure and Femoral Shortening osteotomy, were simulated on the screen to rehearse a virtual treatment plan. Quantitative measurement of Acetabular Index (AI) and Femoral Neck Anteversion (FNA) were performed on the 3D image for evaluation of DDH and treatment plans. PC graphics-card GPU architecture was exploited to accelerate the 3D rendering and geometric manipulation. The prototype system was implemented on PC/Windows environment and is currently under clinical trial on patient datasets.
Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study.
Schmidt-Braekling, Tom; Renner, Lisa; Mintz, Douglas N; Waldstein, Wenzel; Endo, Yoshimi; Boettner, Friedrich
2017-04-01
In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture. Copyright © 2016 Elsevier Inc. All rights reserved.
Hip joint center localisation: A biomechanical application to hip arthroplasty population
Bouffard, Vicky; Begon, Mickael; Champagne, Annick; Farhadnia, Payam; Vendittoli, Pascal-André; Lavigne, Martin; Prince, François
2012-01-01
AIM: To determine hip joint center (HJC) location on hip arthroplasty population comparing predictive and functional approaches with radiographic measurements. METHODS: The distance between the HJC and the mid-pelvis was calculated and compared between the three approaches. The localisation error between the predictive and functional approach was compared using the radiographic measurements as the reference. The operated leg was compared to the non-operated leg. RESULTS: A significant difference was found for the distance between the HJC and the mid-pelvis when comparing the predictive and functional method. The functional method leads to fewer errors. A statistical difference was found for the localization error between the predictive and functional method. The functional method is twice more precise. CONCLUSION: Although being more individualized, the functional method improves HJC localization and should be used in three-dimensional gait analysis. PMID:22919569
Landgraeber, Stefan; Quitmann, Henning; Güth, Sebastian; Haversath, Marcel; Kowalczyk, Wojciech; Kecskeméthy, Andrés; Heep, Hansjörg; Jäger, Marcus
2013-01-01
There is still controversy as to whether minimally invasive total hip arthroplasty enhances the postoperative outcome. The aim of this study was to compare the outcome of patients who underwent total hip replacement through an anterolateral minimally invasive (MIS) or a conventional lateral approach (CON). We performed a randomized, prospective study of 75 patients with primary hip arthritis, who underwent hip replacement through the MIS (n=36) or CON (n=39) approach. The Western Ontario and McMaster Universities Osteoarthritis Index and Harris Hip score (HHS) were evaluated at frequent intervals during the early postoperative follow-up period and then after 3.5 years. Pain sensations were recorded. Serological and radiological analyses were performed. In the MIS group the patients had smaller skin incisions and there was a significantly lower rate of patients with a positive Trendelenburg sign after six weeks postoperatively. After six weeks the HHS was 6.85 points higher in the MIS group (P=0.045). But calculating the mean difference between the baseline and the six weeks HHS we evaluated no significant differences. Blood loss was greater and the duration of surgery was longer in the MIS group. The other parameters, especially after the twelfth week, did not differ significantly. Radiographs showed the inclination of the acetabular component to be significantly higher in the MIS group, but on average it was within the same permitted tolerance range as in the CON group. Both approaches are adequate for hip replacement. Given the data, there appears to be no significant long term advantage to the MIS approach, as described in this study. PMID:24191179
A new technique for radiographic measurement of acetabular cup orientation.
Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn
2014-02-01
Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.
Oxidized zirconium on ceramic; Catastrophic coupling.
Ozden, V E; Saglam, N; Dikmen, G; Tozun, I R
2017-02-01
Oxidized zirconium (Oxinium™; Smith & Nephew, Memphis, TN, USA) articulated with polyethylene in total hip arthroplasty (THA) appeared to have the potential to reduce wear dramatically. The thermally oxidized metal zirconium surface is transformed into ceramic-like hard surface that is resistant to abrasion. The exposure of soft zirconium metal under hard coverage surface after the damage of oxidized zirconium femoral head has been described. It occurred following joint dislocation or in situ succeeding disengagement of polyethylene liner. We reported three cases of misuse of Oxinium™ (Smith & Nephew, Memphis, TN, USA) heads. These three cases resulted in catastrophic in situ wear and inevitable failure although there was no advice, indication or recommendation for this use from the manufacturer. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
The size effects upon shock plastic compression of nanocrystals
NASA Astrophysics Data System (ADS)
Malygin, G. A.; Klyavin, O. V.
2017-10-01
For the first time a theoretical analysis of scale effects upon the shock plastic compression of nanocrystals is implemented in the context of a dislocation kinetic approach based on the equations and relationships of dislocation kinetics. The yield point of crystals τy is established as a quantitative function of their cross-section size D and the rate of shock deformation as τy ɛ2/3 D. This dependence is valid in the case of elastic stress relaxation on account of emission of dislocations from single-pole Frank-Read sources near the crystal surface.
Jaremko, Jacob L; Lambert, Robert G W; Zubler, Veronika; Weber, Ulrich; Loeuille, Damien; Roemer, Frank W; Cibere, Jolanda; Pianta, Marcus; Gracey, David; Conaghan, Philip; Ostergaard, Mikkel; Maksymowych, Walter P
2014-02-01
As a wider variety of therapeutic options for osteoarthritis (OA) becomes available, there is an increasing need to objectively evaluate disease severity on magnetic resonance imaging (MRI). This is more technically challenging at the hip than at the knee, and as a result, few systematic scoring systems exist. The OMERACT (Outcome Measures in Rheumatology) filter of truth, discrimination, and feasibility can be used to validate image-based scoring systems. Our objective was (1) to review the imaging features relevant to the assessment of severity and progression of hip OA; and (2) to review currently used methods to grade these features in existing hip OA scoring systems. A systematic literature review was conducted. MEDLINE keyword search was performed for features of arthropathy (such as hip + bone marrow edema or lesion, synovitis, cyst, effusion, cartilage, etc.) and scoring system (hip + OA + MRI + score or grade), with a secondary manual search for additional references in the retrieved publications. Findings relevant to the severity of hip OA include imaging markers associated with inflammation (bone marrow lesion, synovitis, effusion), structural damage (cartilage loss, osteophytes, subchondral cysts, labral tears), and predisposing geometric factors (hip dysplasia, femoral-acetabular impingement). Two approaches to the semiquantitative assessment of hip OA are represented by Hip OA MRI Scoring System (HOAMS), a comprehensive whole organ assessment of nearly all findings, and the Hip Inflammation MRI Scoring System (HIMRISS), which selectively scores only active lesions (bone marrow lesion, synovitis/effusion). Validation is presently confined to limited assessment of reliability. Two methods for semiquantitative assessment of hip OA on MRI have been described and validation according to the OMERACT Filter is limited to evaluation of reliability.
Role Of Impurities On Deformation Of HCP Crystal: A Multi-Scale Approach
NASA Astrophysics Data System (ADS)
Bhatia, Mehul Anoopkumar
Commercially pure (CP) and extra low interstitial (ELI) grade Ti-alloys present excellent corrosion resistance, lightweight, and formability making them attractive materials for expanded use in transportation and medical applications. However, the strength and toughness of CP titanium are affected by relatively small variations in their impurity/solute content (IC), e.g., O, Al, and V. This increase in strength is due to the fact that the solute either increases the critical stress required for the prismatic slip systems ({10- 10}) or activates another slip system ((0001), {10-11}). In particular, solute additions such as O can effectively strengthen the alloy but with an attendant loss in ductility by changing the behavior from wavy (cross slip) to planar nature. In order to understand the underlying behavior of strengthening by solutes, it is important to understand the atomic scale mechanism. This dissertation aims to address this knowledge gap through a synergistic combination of density functional theory (DFT) and molecular dynamics. Further, due to the long-range strain fields of the dislocations and the periodicity of the DFT simulation cells, it is difficult to apply ab initio simulations to study the dislocation core structure. To alleviate this issue we developed a multiscale quantum mechanics/molecular mechanics approach (QM/MM) to study the dislocation core. We use the developed QM/MM method to study the pipe diffusion along a prismatic edge dislocation core. Complementary to the atomistic simulations, the Semi-discrete Variational Peierls-Nabarro model (SVPN) was also used to analyze the dislocation core structure and mobility. The chemical interaction between the solute/impurity and the dislocation core is captured by the so-called generalized stacking fault energy (GSFE) surface which was determined from DFT-VASP calculations. By taking the chemical interaction into consideration the SVPN model can predict the dislocation core structure and mobility in the presence and absence of the solute/impurity and thus reveal the effect of impurity/solute on the softening/hardening behavior in alpha-Ti. Finally, to study the interaction of the dislocation core with other planar defects such as grain boundaries (GB), we develop an automated method to theoretically generate GBs in HCP type materials.
NASA Astrophysics Data System (ADS)
Mehrotra, A.; Alemu, A.; Freundlich, A.
2011-02-01
Crystalline defects (e.g. dislocations or grain boundaries) as well as electron and proton induced defects cause reduction of minority carrier diffusion length which in turn results in degradation of efficiency of solar cells. Hetro-epitaxial or metamorphic III-V devices with low dislocation density have high BOL efficiencies but electron-proton radiation causes degradation in EOL efficiencies. By optimizing the device design (emitter-base thickness, doping) we can obtain highly dislocated metamorphic devices that are radiation resistant. Here we have modeled III-V single and multi junction solar cells using drift and diffusion equations considering experimental III-V material parameters, dislocation density, 1 Mev equivalent electron radiation doses, thicknesses and doping concentration. Thinner device thickness leads to increment in EOL efficiency of high dislocation density solar cells. By optimizing device design we can obtain nearly same EOL efficiencies from high dislocation solar cells than from defect free III-V multijunction solar cells. As example defect free GaAs solar cell after optimization gives 11.2% EOL efficiency (under typical 5x1015cm-2 1 MeV electron fluence) while a GaAs solar cell with high dislocation density (108 cm-2) after optimization gives 10.6% EOL efficiency. The approach provides an additional degree of freedom in the design of high efficiency space cells and could in turn be used to relax the need for thick defect filtering buffer in metamorphic devices.
Controversies in the Management of the First Time Shoulder Dislocation
Avila Lafuente, José Luis; Moros Marco, Santos; García Pequerul, José Manuel
2017-01-01
Background: Traditionally, initial management of first anterior shoulder dislocations consists of reduction of the glenohumeral joint followed by a period of immobilization and subsequent physical therapy to recover shoulder range of motion and strength. This traditional approach in management is now controversial due to the high rate of recurrence. The aim of this paper is to review and discuss the literature about the global management of patients presenting with first-time traumatic anterior glenohumeral dislocation, analyzing the factors that affect shoulder instability after the first episode of dislocation. Methods: Scientific publications about the management of first-time shoulder dislocations are reviewed. Pubmed is used for that and no limit in the year of publication are stablished. These papers and their conclusions are discussed. Results: Younger patients, patient´s activities and the kind of injury are the most important factors related to the shoulder instability after a first time traumatic dislocation. Authors that recommend surgical treatment after the first episode of dislocation argue that the possibilities of recurrence are high and therefore surgery should be performed before its occurrence. Other authors, however, argue that surgical treatment is demanding, and keep in mind that complications, such as recurrence, stiffness and pain after surgery, are still present. Conclusion: Currently, there is still no consensus in the literature with regard to the management of first episode of shoulder dislocation. It is necessary to analyze carefully every individual case to manage them more or less aggressive to obtain the best result in our practice. PMID:29430264
Isenberg, J; Prokop, A; Schellhammer, F; Helling, H J
2002-12-01
Palmar lunate dislocation as the end stage of a perilunate dislocation is a very uncommon injury. Having treated 19,534 hospitalized patients between 1 January 1986 and 1 October 2001 the diagnosis was recorded in four male trauma patients (33, 36, 37 and 62 years old). Among the operatively treated carpal dislocations and carpal fracture dislocations those of the lunate were seen in five per cent. The dislocation was caused in by an acute hyperextension injury resulting of falls from heights in three cases, and of a motorcycle accident in a further case. In two of these cases a complete palmar lunate dislocation was analysed that were produced by fall from seven meters heights of a young craftsman and by accident of a motorcyclist. First using a longitudinal palmar approach in both cases a revision of the hemorrhagic carpal canal was performed urgently, the largely denuded lunate was reduced and the repair of identified ligamentous structures was performed by means of sutures respectively suture anchors. Reduction was stabilized with Kirschner wires. Afterwards performed computed tomography identified the result of reduction and associated defects (subluxation distal radioulnar joint). In one patient a soft tissue infection prevented the dorsal ligamentous repair. In spite of a consequent after-treatment and a good functional result a scapho-lunate dissociation was proved. An avascular defect of the lunate could be excluded by magnetic resonance imaging. In case of a secondary performed dorsal repair a persisting carpal stabilization with a satisfactory functional result could achieved. At second hand an advanced carpal collapse was proved. If reduction cannot be achieved by closed manipulation or a loss of reduction is shown, open reduction is indicated first by a palmar approach. An additional dorsal ligamentous repair seems to be necessary. Transfixation by Kirschner wires and suture anchors stabilize the restored anatomic relationships. Wrist immobilization in a cast for at least eight weeks is recommended. Although ligamentous insufficiency, osteoarthrosis and avascular necrosis are often proved, functional results are satisfactory.
Non-basal dislocations should be accounted for in simulating ice mass flow
NASA Astrophysics Data System (ADS)
Chauve, T.; Montagnat, M.; Piazolo, S.; Journaux, B.; Wheeler, J.; Barou, F.; Mainprice, D.; Tommasi, A.
2017-09-01
Prediction of ice mass flow and associated dynamics is pivotal at a time of climate change. Ice flow is dominantly accommodated by the motion of crystal defects - the dislocations. In the specific case of ice, their observation is not always accessible by means of the classical tools such as X-ray diffraction or transmission electron microscopy (TEM). Part of the dislocation population, the geometrically necessary dislocations (GNDs) can nevertheless be constrained using crystal orientation measurements via electron backscattering diffraction (EBSD) associated with appropriate analyses based on the Nye (1950) approach. The present study uses the Weighted Burgers Vectors, a reduced formulation of the Nye theory that enables the characterization of GNDs. Applied to ice, this method documents, for the first time, the presence of dislocations with non-basal [ c ] or < c + a > Burgers vectors. These [ c ] or < c + a > dislocations represent up to 35% of the GNDs observed in laboratory-deformed ice samples. Our findings offer a more complex and comprehensive picture of the key plasticity processes responsible for polycrystalline ice creep and provide better constraints on the constitutive mechanical laws implemented in ice sheet flow models used to predict the response of Earth ice masses to climate change.
The Stress-Dependent Activation Parameters for Dislocation Nucleation in Molybdenum Nanoparticles.
Chachamovitz, Doron; Mordehai, Dan
2018-03-02
Many specimens at the nanoscale are pristine of dislocations, line defects which are the main carriers of plasticity. As a result, they exhibit extremely high strengths which are dislocation-nucleation controlled. Since nucleation is a thermally activated process, it is essential to quantify the stress-dependent activation parameters for dislocation nucleation in order to study the strength of specimens at the nanoscale and its distribution. In this work, we calculate the strength of Mo nanoparticles in molecular dynamics simulations and we propose a method to extract the activation free-energy barrier for dislocation nucleation from the distribution of the results. We show that by deforming the nanoparticles at a constant strain rate, their strength distribution can be approximated by a normal distribution, from which the activation volumes at different stresses and temperatures are calculated directly. We found that the activation energy dependency on the stress near spontaneous nucleation conditions obeys a power-law with a critical exponent of approximately 3/2, which is in accordance with critical exponents found in other thermally activated processes but never for dislocation nucleation. Additionally, significant activation entropies were calculated. Finally, we generalize the approach to calculate the activation parameters for other driving-force dependent thermally activated processes.
Hip fracture in the elderly: a re-analysis of the EPIDOS study with causal Bayesian networks.
Caillet, Pascal; Klemm, Sarah; Ducher, Michel; Aussem, Alexandre; Schott, Anne-Marie
2015-01-01
Hip fractures commonly result in permanent disability, institutionalization or death in elderly. Existing hip-fracture predicting tools are underused in clinical practice, partly due to their lack of intuitive interpretation. By use of a graphical layer, Bayesian network models could increase the attractiveness of fracture prediction tools. Our aim was to study the potential contribution of a causal Bayesian network in this clinical setting. A logistic regression was performed as a standard control approach to check the robustness of the causal Bayesian network approach. EPIDOS is a multicenter study, conducted in an ambulatory care setting in five French cities between 1992 and 1996 and updated in 2010. The study included 7598 women aged 75 years or older, in which fractures were assessed quarterly during 4 years. A causal Bayesian network and a logistic regression were performed on EPIDOS data to describe major variables involved in hip fractures occurrences. Both models had similar association estimations and predictive performances. They detected gait speed and mineral bone density as variables the most involved in the fracture process. The causal Bayesian network showed that gait speed and bone mineral density were directly connected to fracture and seem to mediate the influence of all the other variables included in our model. The logistic regression approach detected multiple interactions involving psychotropic drug use, age and bone mineral density. Both approaches retrieved similar variables as predictors of hip fractures. However, Bayesian network highlighted the whole web of relation between the variables involved in the analysis, suggesting a possible mechanism leading to hip fracture. According to the latter results, intervention focusing concomitantly on gait speed and bone mineral density may be necessary for an optimal prevention of hip fracture occurrence in elderly people.
von Rüden, C; Hackl, S; Woltmann, A; Friederichs, J; Bühren, V; Hierholzer, C
2015-06-01
The dislocated posterolateral fragment of the distal tibia is considered as a key fragment for the successful reduction of comminuted ankle fractures. The reduction of this fragment can either be achieved indirectly by joint reduction using the technique of closed anterior-posterior screw fixation, or directly using the open posterolateral approach followed by plate fixation. The aim of this study was to compare the outcome after stabilization of the dislocated posterolateral tibia fragment using either closed reduction and screw fixation, or open reduction and plate fixation via the posterolateral approach in complex ankle fractures. In a prospective study between 01/2010 and 12/2012, all mono-injured patients with closed ankle fractures and dislocated posterolateral tibia fragments were assessed 12 months after osteosynthesis. Parameters included: size of the posterolateral tibia fragment relative to the tibial joint surface (CT scan, in %) as an indicator of injury severity, unreduced area of tibial joint surface postoperatively, treatment outcome assessed by using the "Ankle Fracture Scoring System" (AFSS), as well as epidemiological data and duration of the initial hospital treatment. In 11 patients (10 female, 1 male; age 51.6 ± 2.6 years [mean ± SEM], size of tibia fragment 42.1 ± 2.5 %) the fragment fixation was performed using a posterolateral approach. Impaired postoperative wound healing occurred in 2 patients of this group. In the comparison group, 12 patients were treated using the technique of closed anterior-posterior screw fixation (10 female, 2 male; age 59.5 ± 6.7 years, size of tibia fragment 45.9 ± 1.5 %). One patient of this group suffered an incomplete lesion of the superficial peroneal nerve. Radiological evaluation of the joint surface using CT scan imaging demonstrated significantly less dislocation of the tibial joint surface following the open posterolateral approach (0.60 ± 0.20 mm) compared to the closed anterior-posterior screw fixation (1.03 ± 0.08 mm; p < 0.05). Assessment of the treatment outcome using the AFSS demonstrated a significantly higher score of 97.4 ± 6.4 in the group with a posterolateral approach compared to a score of 74.4 ± 12.1 (p < 0.05) in the group with an anterior-posterior screw fixation. In comparison to the anterior-posterior screw fixation, open reduction and fixation of the dislocated, posterolateral key fragment of the distal tibia using a posterolateral approach resulted in a more accurate fracture reduction and significantly better functional outcome 12 months after surgery. In addition, no increased rate of postoperative complications, or extended hospital stay was observed but there was less severe post-traumatic joint arthritis. The results of this study suggest that in complex ankle factures the open fixation of the dislocated posterolateral fragment is recommended as an alternative surgical procedure and may be beneficial for both clinical and radiological long-term outcomes. Georg Thieme Verlag KG Stuttgart · New York.
Combined Volar Hamate Dislocation and Scapholunate Ligament Rupture: A Case Report.
Walmsley, David; Dhotar, Herman; Geddes, Christopher; Axelrod, Terry
2015-04-22
A twenty-two-year-old male patient presented to our trauma center after a motor-vehicle accident in which he sustained multiple injuries, including a volar dislocation of the hamate and ipsilateral scapholunate dissociation. Following closed reduction of the hamate dislocation, open reduction and stabilization of these carpal injuries was undertaken two days post-injury via a dorsal approach. Percutaneous Kirschner wires were used as well as two mini suture anchors to repair the scapholunate ligament. The patient was immobilized for six weeks and Kirschner wires were removed at twelve weeks postoperatively. To our knowledge, hamate dislocation with scapholunate dissociation and its surgical treatment have not previously been described. Successful surgical treatment for this injury pattern may be performed dorsally via direct reduction and repair of the scapholunate ligament with percutaneous pinning of the affected carpal bones.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Askari, Hesam; Zbib, Hussein M.; Sun, Xin
In this study, the strengthening effect of inclusions and precipitates in metals is investigated within a multiscale approach that utilizes models at various length scales, namely, Molecular Mechanics (MM), discrete Dislocation Dynamics (DD), and an Eigenstrain Inclusion Method (EIM). Particularly, precipitates are modeled as hardsoft particles whose stress fields interact with dislocations. The stress field resulting from the elastic mismatch between the particles and the matrix is accounted for through the EIM. While the MM method is employed for the purpose of developing rules for DD for short range interaction between a single dislocation and an inclusion, the DD methodmore » is used to predict the strength of the composite resulting from the interaction between ensembles of dislocations and particles. As an application to this method, the mechanical behavior of Advanced High Strength Steel (AHSS) is investigated and the results are then compared to the experimental data. The results show that the finely dispersive precipitates can strengthen the material by pinning the dislocations up to a certain shear stress and retarding the recovery, as well as annihilation of dislocations. The DD results show that strengthening due to nano sized particles is a function of the density and size of the precipitates. This size effect is then explained using a mechanistic model developed based on dislocation-particle interaction.« less
Shi, Dan; Patil, Pavan Manohar; Gupta, Ritika
2015-04-01
To document facial nerve (FN) injuries after surgical treatment of mandibular condylar fractures using the retromandibular transparotid approach and to identify risk factors associated with these injuries. A retrospective study of patients surgically treated for mandibular condylar fractures using the retromandibular transparotid approach over seven years was conducted. The primary study variable was the postoperative change in FN function after fracture fixation. Risk factors were categorized as demographic, anatomic, experience of the operator, fracture displacement/dislocation and number of miniplates placed at the fracture site. Appropriate statistics were computed. Ninety patients with 102 fractures were analysed. Thirty two fractures (31%) were located in the condylar neck and 70 fractures (69%) were subcondylar (located below the sigmoid notch). The condylar segment was undisplaced in twelve cases (12%), displaced medially in thirty five (34%), laterally displaced in thirty (29%) and dislocated in 25 (24.5%). In 18 fractures (18%), postoperative examination revealed various degrees of damage to the FN. All nerve injuries recovered completely in 8-24 weeks. In a multivariate model, condylar neck fractures, fracture dislocation and operator inexperience were associated with a statistically significant risk of postoperative deterioration of FN function (P ≤ 0.05). The majority of facial nerve injuries after surgical treatment of condylar fractures by the retromandibular transparotid approach are transient in nature. Condylar neck fractures, fracture dislocation and operator inexperience were associated with an increased risk for FN injury. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
van der Linde, M J; Tonino, A J
1997-12-01
In 600 consecutive uncemented total hip replacements, 2 surgical approaches were used: the direct lateral Hardinge approach in supine position (group I: 241 cases) or in a lateral position (group II: 280 cases) and the anterolateral Watson-Jones approach in supine position (group III: 79 cases). 5 patients had clinically evident peripheral nerve injuries confirmed with EMG: none in group I, 1 lesion of the nervus ischiadicus and nervus femoralis in group II and 4 nervus femoralis lesions in group III, of which 1 was combined with an obturator nerve injury. The nerve injuries were evaluated with EMG. All 4 nervus femoralis lesions recovered spontaneously, but the one patients in group II had a persistent palsy of the peroneal nerve. The anatomical basis for the higher prevalence of nervus femoralis lesions in the anterolateral Watson-Jones approach is described.
Analysis of Femoral Components of Cemented Total Hip Arthroplasty
NASA Astrophysics Data System (ADS)
Singh, Shantanu; Harsha, A. P.
2016-10-01
There have been continuous on-going revisions in design of prosthesis in Total Hip Arthroplasty (THA) to improve the endurance of hip replacement. In the present work, Finite Element Analysis was performed on cemented THA with CoCrMo trapezoidal, CoCrMo circular, Ti6Al4V trapezoidal and Ti6Al4V circular stem. It was observed that cross section and material of femoral stem proved to be critical parameters for stress distribution in femoral components, distribution of interfacial stress and micro movements. In the first part of analysis, designs were investigated for micro movements and stress developed, for different stem materials. Later part of the analysis focused on investigations with respect to different stem cross sections. Femoral stem made of Titanium alloy (Ti6Al4V) resulted in larger debonding of stem at cement-stem interface and increased stress within the cement mantle in contrast to chromium alloy (CoCrMo) stem. Thus, CoCrMo proved to be a better choice for cemented THA. Comparison between CoCrMo femoral stem of trapezium and circular cross section showed that trapezoidal stem experiences lesser sliding and debonding at interfaces than circular cross section stem. Also, trapezium cross section generated lower peak stress in femoral stem and cortical femur. In present study, femur head with diameter of 36 mm was considered for the analysis in order to avoid dislocation of the stem. Also, metallic femur head was coupled with cross linked polyethylene liner as it experiences negligible wear compared to conventional polyethylene liner and unlike metallic liner it is non carcinogenic.
Developmental dysplasia of the hip in the newborn: A systematic review
Gulati, Vivek; Eseonu, Kelechi; Sayani, Junaid; Ismail, Nizar; Uzoigwe, Chika; Choudhury, Muhammed Zaki; Gulati, Pooja; Aqil, Adeel; Tibrewal, Saket
2013-01-01
Developmental dysplasia of the hip (DDH) denotes a wide spectrum of conditions ranging from subtle acetabular dysplasia to irreducible hip dislocations. Clinical diagnostic tests complement ultrasound imaging in allowing diagnosis, classification and monitoring of this condition. Classification systems relate to the alpha and beta angles in addition to the dynamic coverage index (DCI). Screening programmes for DDH show considerable geographic variation; certain risk factors have been identified which necessitate ultrasound assessment of the newborn. The treatment of DDH has undergone significant evolution, but the current gold standard is still the Pavlik harness. Duration of Pavlik harness treatment has been reported to range from 3 to 9.3 mo. The beta angle, DCI and the superior/lateral femoral head displacement can be assessed via ultrasound to estimate the likelihood of success. Success rates of between 7% and 99% have been reported when using the harness to treat DDH. Avascular necrosis remains the most devastating complication of harness usage with a reported rate of between 0% and 28%. Alternative non-surgical treatment methods used for DDH include devices proposed by LeDamany, Frejka, Lorenz and Ortolani. The Rosen splint and Wagner stocking have also been used for DDH treatment. Surgical treatment for DDH comprises open reduction alongside a combination of femoral or pelvic osteotomies. Femoral osteotomies are carried out in cases of excessive anteversion or valgus deformity of the femoral neck. The two principal pelvic osteotomies most commonly performed are the Salter osteotomy and Pemberton acetabuloplasty. Serious surgical complications include epiphyseal damage, sciatic nerve damage and femoral neck fracture. PMID:23610749
Assessing risk factors for early hip osteoarthritis in activity-related hip pain: a Delphi study
Jackson, K A; Glyn-Jones, S; Batt, M E; Arden, N K; Newton, J L
2015-01-01
Objective Hip pain and injury as a result of activity can lead to the development of early hip osteoarthritis (OA) in susceptible individuals. Our understanding of the factors that increase susceptibility continues to evolve. The ability to clearly identify individuals (and cohorts) with activity-related hip pain who are at risk of early hip OA is currently lacking. The purpose of this study was to gain expert consensus on which key clinical measures might help predict the risk of early hip OA in individuals presenting with activity-related hip pain. The agreed measures would constitute a standardised approach to initial clinical assessment to help identify these individuals. Methods This Dephi study used online surveys to gain concordance of expert opinion in a structured process of ‘rounds’. In this study, we asked ‘What outcome measures are useful in predicting hip OA in activity-related hip pain?’ The Delphi panel consisted of experts from sport and exercise medicine, orthopaedics, rheumatology, physiotherapy and OA research. Results The study identified key clinical measures in the history, examination and investigations (plain anteroposterior radiograph and femoroacetabular impingement views) that the panel agreed would be useful in predicting future risk of hip OA when assessing activity-related hip pain. The panel also agreed that certain investigations and tests (eg, MR angiography) did not currently have a role in routine assessment. There was a lack of consensus regarding the role of MRI, patient-reported outcome measures (PROMs) and certain biomechanical and functional assessments. Conclusions We provide a standardised approach to the clinical assessment of patients with activity-related hip pain. Assessment measures rejected by the Delphi panel were newer, more expensive investigations that currently lack evidence. Assessment measures that did not reach consensus include MRI and PROMs. Their role remains ambiguous and would benefit from further research. PMID:26419679
Controversies in Treatment of Acetabular Fracture
Grubor, Predrag; Krupic, Ferid; Biscevic, Mirza; Grubor, Milan
2015-01-01
Introduction: Acetabular fractures treatment represents a great controversy, challenge and dilemma for an orthopedic surgeon. Aim: The aim of the paper was to present the results of treatment of 96 acetabular fractures in the Clinic of Traumatology Banja Luka, in the period from 2003 to 2013, as well as to raise awareness regarding the controversy in the methods of choice in treating acetabulum fractures. Material and methods: The series consists of 96 patients, 82 males and 14 females, average age 40.5 years. Traffic trauma was the cause of fractures in 79 patients (85%), and in 17 patients (15%) fractures occurred due to falls from height. Polytrauma was present in 31 patients (32%). According to the classification of Judet and Letournel, representation of acetabular fractures was as follows: posterior wall in 32 patients, posterior column in 28, anterior wall in 4, anterior column in 2, transverse fractures in 8, posterior wall and posterior column in 10, anterior and posterior wall in 6, both- column in 4 and transversal fracture and posterior wall in 2 patients. 14 patients were treated with traction, that is, 6 patients with femoral traction and 8 patients with both lateral and femoral traction. 82 patients (86.4%) were surgically treated. Kocher-Langenbeck approach was applied in the treatment of 78 patients. In two patients from the Kocher-Langenbeck’s approach, the Ollier’s approach had to be applied as well. Two acetabular were primarily treated with Ollier’s approach. Extended Smith- Peterson’s approach was applied 4 times, and Emile Letournel’s (ilioinguinal) approach 14 times. Results: Functional outcome (after follow-up of 18 months), according to the Harris hip score of surgical treatment in 82 patients, was as follows: good 46 (56%), satisfactory 32 (39%) and poor 4 (5%). Results of acetabulum fractures treated with traction were: good 8 (57%), satisfactory 4 (28%) and poor 2 (15%). According to the Brook’s classification of heterotopic ossification, periarticular hetero-tropic calcifications after surgical treatment were: 0° in 65 patients (79%), I-II° in 9 patients (11%) and III-IV ° in 8 patients (10%). Calcifications in 14 patients treated with traction of heterotopic ossification by Brook-s classification were as follows: 0° in 10 patients (72%), I-II ° in 3 patients (22%) and III-IV° in 1 patient (6%). Conclusion: At the occurrence of acetabular fracture, it is necessary to start the treatment immediately, with an obligatory application of thromboembolic and antibiotic prophylaxis. Conservative treatment is acceptable if the dislocation of fracture is less than 5 mm. Indications for surgical treatment are incongruent or unstable fractures with verified dislocation greater than 5 mm, as well as when the radiography measured by JM Matta shows incongruence of acetabular roof less than 40° in all planes. Kocher-Langenbeck approach is the choice of surgical approach for the management of posterior column / wall, and Letournel’s (ilioinguinal) approach is the choice for the management of anterior wall/column. PMID:25870470
An approach to enhance self-compensation capability in paper-based devices for chemical sensing.
Lo, Shih-Jie; Chen, Kuan-Hung; Yao, Da-Jeng
2015-12-01
This paper describes a simple design for increasing the tolerance of reagent dislocation on a paper-based platform using a combination of wax-treated paper and a vortex mixer. To date, massive budgetary funds are required in the biotechnological industry to develop new applications; a large part of that cost is attributable to the screening of specific chemical compounds. Here, we propose using a liquid-handling robot to automatically deposit selected reagents on a paper-based platform. We also present a preliminary concept approach for developing a reagent placing device with simple and inexpensive features. A defect of inaccuracy was observed between droplet location and test well location after viewing the performance of the liquid-handling robot on our paper-based platform. Because of dislocation error resulting from robotic reagent placement, we decided to apply an external, rotational force following droplet placement in order to compensate for the distance of reagent dislocation. Note, the largest distance of reagent dislocation was determined by examining the results of altering applied reagent volume, but not concentration, in volumes from 5 µL to 30 µL in a series of experiments. As a result of these experiments, we observed that dislocation was positively affected by an increase in applied volume. A colorimetric assay for nitrite detection was also performed to confirm the feasibility of this method. This work, we believe, can minimize the cost of chemical compound screening for the biotechnological industry. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bollinger, C.; Idrissi, H.; Boioli, F.; Cordier, P.
2015-12-01
There is a growing consensus to recognize that rheological law established for olivine at high-temperature (ca. >1000°C) fail when extrapolated to low temperatures relevant for the lithospheric mantle. Hence it appears necessary to fit rheological laws against data at low temperatures where olivine tends to become more and more brittle. The usual approach consists in applying confining pressure to inhibit brittleness. Here we propose an innovative approach based on the use of very small samples and numerical modelling. New commercial in situ TEM nanotensile testing equipment recently developed by Hysitron.Inc is combined with weak-beam dark-field TEM diffraction contrast imaging in order to obtain information on the elementary mechanisms controlling the plasticity of olivine: namely glide of [001] screw dislocations. The olivine tensile beams dedicated for in situ TEM nanomechanical testing were produced using microfabrication techniques based on MEMS-type procedures. The testing geometry was designed as to induce maximum resolved shear stresses on the [001](110) slip system. Under tensile loads between 2 and 3 GPa, ductile behaviour was reached with the development and propagation of dislocation loops across the sample allowing to measure the velocity of screw and non-screw dislocations as a function of stress. This information is introduced into a numerical model involving Dislocation Dynamics in order to obtain the stress-strain curves describing the mechanical response of olivine single crystals deformed in tension at room temperature.
Murphy, Nicholas J; Eyles, Jillian; Bennell, Kim L; Bohensky, Megan; Burns, Alexander; Callaghan, Fraser M; Dickenson, Edward; Fary, Camdon; Grieve, Stuart M; Griffin, Damian R; Hall, Michelle; Hobson, Rachel; Kim, Young Jo; Linklater, James M; Lloyd, David G; Molnar, Robert; O'Connell, Rachel L; O'Donnell, John; O'Sullivan, Michael; Randhawa, Sunny; Reichenbach, Stephan; Saxby, David J; Singh, Parminder; Spiers, Libby; Tran, Phong; Wrigley, Tim V; Hunter, David J
2017-09-26
Femoroacetabular impingement syndrome (FAI), a hip disorder affecting active young adults, is believed to be a leading cause of hip osteoarthritis (OA). Current management approaches for FAI include arthroscopic hip surgery and physiotherapy-led non-surgical care; however, there is a paucity of clinical trial evidence comparing these approaches. In particular, it is unknown whether these management approaches modify the future risk of developing hip OA. The primary objective of this randomised controlled trial is to determine if participants with FAI who undergo hip arthroscopy have greater improvements in hip cartilage health, as demonstrated by changes in delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) index between baseline and 12 months, compared to those who undergo physiotherapy-led non-surgical management. This is a pragmatic, multi-centre, two-arm superiority randomised controlled trial comparing hip arthroscopy to physiotherapy-led management for FAI. A total of 140 participants with FAI will be recruited from the clinics of participating orthopaedic surgeons, and randomly allocated to receive either surgery or physiotherapy-led non-surgical care. The surgical intervention involves arthroscopic FAI surgery from one of eight orthopaedic surgeons specialising in this field, located in three different Australian cities. The physiotherapy-led non-surgical management is an individualised physiotherapy program, named Personalised Hip Therapy (PHT), developed by a panel to represent the best non-operative care for FAI. It entails at least six individual physiotherapy sessions over 12 weeks, and up to ten sessions over six months, provided by experienced musculoskeletal physiotherapists trained to deliver the PHT program. The primary outcome measure is the change in dGEMRIC score of a ROI containing both acetabular and femoral head cartilages at the chondrolabral transitional zone of the mid-sagittal plane between baseline and 12 months. Secondary outcomes include patient-reported outcomes and several structural and biomechanical measures relevant to the pathogenesis of FAI and development of hip OA. Interventions will be compared by intention-to-treat analysis. The findings will help determine whether hip arthroscopy or an individualised physiotherapy program is superior for the management of FAI, including for the prevention of hip OA. Australia New Zealand Clinical Trials Registry reference: ACTRN12615001177549 . Trial registered 2/11/2015 (retrospectively registered).
A FFT-based formulation for discrete dislocation dynamics in heterogeneous media
NASA Astrophysics Data System (ADS)
Bertin, N.; Capolungo, L.
2018-02-01
In this paper, an extension of the DDD-FFT approach presented in [1] is developed for heterogeneous elasticity. For such a purpose, an iterative spectral formulation in which convolutions are calculated in the Fourier space is developed to solve for the mechanical state associated with the discrete eigenstrain-based microstructural representation. With this, the heterogeneous DDD-FFT approach is capable of treating anisotropic and heterogeneous elasticity in a computationally efficient manner. In addition, a GPU implementation is presented to allow for further acceleration. As a first example, the approach is used to investigate the interaction between dislocations and second-phase particles, thereby demonstrating its ability to inherently incorporate image forces arising from elastic inhomogeneities.
Enocson, Anders; Blomfeldt, Richard
2014-06-01
To investigate the clinical and radiologic outcomes in elderly patients suffering from an acetabular fracture operated with an acute primary acetabular reinforcement ring, autologous bone graft, and a total hip arthroplasty (THA). Prospective cohort study. Tertiary care university hospital. Fifteen elderly patients (7 women) with a mean age of 76 years and a displaced acetabular fracture after a low-energy trauma were included. The fractures involved the anterior column, but no patients with associated both column fractures were included. All the patients were able to walk independently before the fracture occurred. Primary operation with a Burch-Schneider reinforcement ring, autologous bone graft, and a THA. The patients were reviewed at 4, 12, 24, and 48 months after the fracture occurred. The outcome assessments included complications, reoperations, activity of daily living function, functional scores (Harris hip score and short musculoskeletal function assessment), health-related quality of life [EuroQol (EQ-5D) index score], and radiologic evaluation. There were no prosthetic dislocations, periprosthetic fractures, deep infections, or other adverse events. There were no radiologic signs of loosening of the reinforcement ring or the prosthesis components at any of the follow up sessions, and the autologous bone graft was well incorporated in all the patients at the final follow-up. At 48 months, the mean Harris hip score was 88, the mean short musculoskeletal function assessment dysfunction score was 30, the bother score was 25, and the mean EQ-5D index score was 0.65. All the patients were able to walk independently at the final follow-up. Treatment of displaced anterior column, anterior column posterior hemitransverse and transverse acetabular fractures in elderly patients using a primary reinforcement ring, autologous bone graft, and a THA seems to be a safe option with good functional and radiologic outcomes. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
NASA Astrophysics Data System (ADS)
Vattré, A.
2017-08-01
A parametric energy-based framework is developed to describe the elastic strain relaxation of interface dislocations. By means of the Stroh sextic formalism with a Fourier series technique, the proposed approach couples the classical anisotropic elasticity theory with surface/interface stress and elasticity properties in heterogeneous interface-dominated materials. For any semicoherent interface of interest, the strain energy landscape is computed using the persistent elastic fields produced by infinitely periodic hexagonal-shaped dislocation configurations with planar three-fold nodes. A finite element based procedure combined with the conjugate gradient and nudged elastic band methods is applied to determine the minimum-energy paths for which the pre-computed energy landscapes yield to elastically favorable dislocation reactions. Several applications on the Au/Cu heterosystems are given. The simple and limiting case of a single set of infinitely periodic dislocations is introduced to determine exact closed-form expressions for stresses. The second limiting case of the pure (010) Au/Cu heterophase interfaces containing two crossing sets of straight dislocations investigates the effects due to the non-classical boundary conditions on the stress distributions, including separate and appropriate constitutive relations at semicoherent interfaces and free surfaces. Using the quantized Frank-Bilby equation, it is shown that the elastic strain landscape exhibits intrinsic dislocation configurations for which the junction formation is energetically unfavorable. On the other hand, the mismatched (111) Au/Cu system gives rise to the existence of a minimum-energy path where the fully strain-relaxed equilibrium and non-regular intrinsic hexagonal-shaped dislocation rearrangement is accompanied by a significant removal of the short-range elastic energy.
Effects of plasma hydrogenation on trapping properties of dislocations in heteroepitaxial InP/GaAs
NASA Technical Reports Server (NTRS)
Ringel, S. A.; Chatterjee, B.
1994-01-01
In previous work, we have demonstrated the effectiveness of a post-growth hydrogen plasma treatment for passivating the electrical activity of dislocations in metalorganic chemical vapor deposition (MOCVD) grown InP on GaAs substrates by a more than two order of magnitude reduction in deep level concentration and an improvement in reverse bias leakage current by a factor of approximately 20. These results make plasma hydrogenation an extremely promising technique for achieving high efficiency large area and light weight heteroepitaxial InP solar cells for space applications. In this work we investigate the carrier trapping process by dislocations in heteroepitaxial InP/GaAs and the role of hydrogen passivation on this process. It is shown that the charge trapping kinetics of dislocations after hydrogen passivation are significantly altered, approaching point defect-like behavior consistent with a transformation from a high concentration of dislocation-related defect bands within the InP bandgap to a low concentration of individual dislocation related deep levels, before and after passivation. It is further shown that the 'apparent' activation energies of dislocation related deep levels, before and after passivation, reduce by approximately 70 meV as DLTS fill pulse times are increased from 1 microsecond to 1 millisecond. A model is proposed which explains these effects based on a reduction of Coulombic interaction between individual core sites along the dislocation cores by hydrogen incorporation. Knowledge of the trapping properties in these specific structures is important to develop optimum, low loss heteroepitaxial InP cells.
NASA Astrophysics Data System (ADS)
Ananthakrishna, G.; K, Srikanth
2018-03-01
It is well known that plastic deformation is a highly nonlinear dissipative irreversible phenomenon of considerable complexity. As a consequence, little progress has been made in modeling some well-known size-dependent properties of plastic deformation, for instance, calculating hardness as a function of indentation depth independently. Here, we devise a method of calculating hardness by calculating the residual indentation depth and then calculate the hardness as the ratio of the load to the residual imprint area. Recognizing the fact that dislocations are the basic defects controlling the plastic component of the indentation depth, we set up a system of coupled nonlinear time evolution equations for the mobile, forest, and geometrically necessary dislocation densities. Within our approach, we consider the geometrically necessary dislocations to be immobile since they contribute to additional hardness. The model includes dislocation multiplication, storage, and recovery mechanisms. The growth of the geometrically necessary dislocation density is controlled by the number of loops that can be activated under the contact area and the mean strain gradient. The equations are then coupled to the load rate equation. Our approach has the ability to adopt experimental parameters such as the indentation rates, the geometrical parameters defining the Berkovich indenter, including the nominal tip radius. The residual indentation depth is obtained by integrating the Orowan expression for the plastic strain rate, which is then used to calculate the hardness. Consistent with the experimental observations, the increasing hardness with decreasing indentation depth in our model arises from limited dislocation sources at small indentation depths and therefore avoids divergence in the limit of small depths reported in the Nix-Gao model. We demonstrate that for a range of parameter values that physically represent different materials, the model predicts the three characteristic features of hardness, namely, increase in the hardness with decreasing indentation depth, and the linear relation between the square of the hardness and the inverse of the indentation depth, for all but 150 nm, deviating for smaller depths. In addition, we also show that it is straightforward to obtain optimized parameter values that give good fit to the hardness data for polycrystalline cold worked copper and single crystals of silver.
Evaluation of the Hip: History and Physical Examination
2007-01-01
Examination of a painful hip is fairly concise and reliable at detecting the presence of a hip joint problem. Hip joint disorders often go undetected, leading to the development of secondary disorders. Using a thoughtful approach and methodical examination techniques, most hip joint problems can be detected and a proper treatment strategy can then be implemented based on an accurate diagnosis. The purpose of this clinical commentary is to present a systematic examination process that outlines important components in each of the evaluation areas of history and physical examination (including inspection, measurements, symptom localization, muscle strength, and special tests). PMID:21509142
Chabaud, Aurore; Eschalier, Bénédicte; Zullian, Myriam; Plan-Paquet, Anne; Aubreton, Sylvie; Saragaglia, Dominique; Descamps, Stéphane; Coudeyre, Emmanuel
2018-05-01
Providing patients with validated information before total hip arthroplasty may help lessen discrepancies between patients' expectations and the surgical result. This study sought to validate an information booklet for candidates for hip arthroplasty by using a mixed qualitative and quantitative approach based on a panel of patients and a sample of healthcare professionals. We developed a booklet in accordance with the standard methods and then conducted focus groups to collect the opinions of a sample of multidisciplinary experts involved in the care of patients with hip osteoarthritis. The number of focus groups and experts was determined according to the data saturation principle. A panel of patients awaiting hip arthroplasty or those in the immediate post-operative period assessed the booklet with self-reporting questionnaires (knowledge, beliefs, and expectations) and semi-structured interviews. All experts and both patient groups validated the booklet in terms of content and presentation. Semi-structured interviews were uninformative, especially for post-operative patients. Reading the booklet significantly (P<0.001) improved the knowledge scores in both groups, with no intergroup differences, but did not affect beliefs in either patient group. Only pre-operative patients significantly changed their expectations. Our mixed qualitative and quantitative approach allowed us to validate a booklet for patients awaiting hip arthroplasty, taking into account the opinions of both patients and healthcare professionals. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Sheehan, Katie J; Sobolev, Boris; Guy, Pierre; Bohm, Eric; Hellsten, Erik; Sutherland, Jason M; Kuramoto, Lisa; Jaglal, Susan
2016-02-01
Episodes of care defined by the event of hip fracture surgery are widely used for the assessment of surgical wait times and outcomes. However, this approach does not consider nonoperative deaths, implying that survival time begins at the time of procedure. This approach makes treatment effect implicitly conditional on surviving to treatment. The purpose of this article is to describe a novel conceptual framework for constructing an episode of hip fracture care to fully evaluate the incidence of adverse events related to time after admission for hip fracture. This admission-based approach enables the assessment of the full harm of delay by including deaths while waiting for surgery, not just deaths after surgery. Some patients wait until their conditions are optimized for surgery, whereas others have to wait until surgical service becomes available. We provide definitions, linkage rules, and algorithms to capture all hip fracture patients and events other than surgery. Finally, we discuss data elements for stratifying patients according to administrative factors for delay to allow researchers and policymakers to determine who will benefit most from expedited access to surgery. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Risk Factors for Migration, Fracture, and Dislocation of Pancreatic Stents
Kawaguchi, Yoshiaki; Lin, Jung-Chun; Kawashima, Yohei; Maruno, Atsuko; Ito, Hiroyuki; Ogawa, Masami; Mine, Tetsuya
2015-01-01
Aim. To analyze the risk factors for pancreatic stent migration, dislocation, and fracture in chronic pancreatitis patients with pancreatic strictures. Materials and Methods. Endoscopic stent placements (total 386 times) were performed in 99 chronic pancreatitis patients with pancreatic duct stenosis at our institution between April 2006 and June 2014. We retrospectively examined the frequency of stent migration, dislocation, and fracture and analyzed the patient factors and stent factors. We also investigated the retrieval methods for migrated and fractured stents and their success rates. Results. The frequencies of stent migration, dislocation, and fracture were 1.5% (5/396), 0.8% (3/396), and 1.2% (4/396), respectively. No significant differences in the rates of migration, dislocation, or fracture were noted on the patient factors (etiology, cases undergoing endoscopic pancreatic sphincterotomy, location of pancreatic duct stenosis, existence of pancreatic stone, and approach from the main or minor papilla) and stent factors (duration of stent placement, numbers of stent placements, stent shape, diameter, and length). Stent retrieval was successful in all cases of migration. In cases of fractured stents, retrieval was successful in 2 of 4 cases. Conclusion. Stent migration, fracture, and dislocation are relatively rare, but possible complications. A good understanding of retrieval techniques is necessary. PMID:25945085
In Situ TEM Study of Interaction between Dislocations and a Single Nanotwin under Nanoindentation.
Wang, Bo; Zhang, Zhenyu; Cui, Junfeng; Jiang, Nan; Lyu, Jilei; Chen, Guoxin; Wang, Jia; Liu, Zhiduo; Yu, Jinhong; Lin, Chengte; Ye, Fei; Guo, Dongming
2017-09-06
Nanotwinned (nt) materials exhibit excellent mechanical properties, and have been attracting much more attention of late. Nevertheless, the fundamental mechanism of interaction between dislocations and a single nanotwin is not understood. In this study, in situ transmission electron microscopy (TEM) nanoindentation is performed, on a specimen of a nickel (Ni) alloy containing a single nanotwin of 89 nm in thickness. The specimen is prepared using focused ion beam (FIB) technique from an nt surface, which is formed by a novel approach under indentation using a developed diamond panel with tips array. The stiffness of the specimen is ten times that of the pristine counterparts during loading. The ultrahigh stiffness is attributed to the generation of nanotwins and the impediment of the single twin to the dislocations. Two peak loads are induced by the activation of a new slip system and the penetration of dislocations over the single nanotwin, respectively. One slip band is parallel to the single nanotwin, indicating the slip of dislocations along the nanotwin. In situ TEM observation of nanoindentation reveals a new insight for the interaction between dislocations and a single nanotwin. This paves the way for design and preparation of high-performance nt surfaces of Ni alloys used for aircraft engines, gas turbines, turbocharger components, ducts, and absorbers.
Trends in German Hip Hop Music and Its Usefulness for the Classroom
ERIC Educational Resources Information Center
Schmidt, Johannes
2008-01-01
German hip hop music has proved productive, especially since 2000 when rap in Germany experienced something like a first crisis. As a response, German hip hop artists and record labels have ventured off in several different directions including other musical genres, different topics, and new approaches to German rap. This article discusses the…
Gamba, Bruno F; Zechi-Ceide, Roseli M; Kokitsu-Nakata, Nancy M; Vendramini-Pittoli, Siulan; Rosenberg, Carla; Krepischi Santos, Ana C V; Ribeiro-Bicudo, Lucilene; Richieri-Costa, Antonio
2016-11-01
We report on a Brazilian patient with a 1.7-Mb interstitial microdeletion in chromosome 1q21.1. The phenotypic characteristics include microcephaly, a peculiar facial gestalt, cleft lip/palate, and multiple skeletal anomalies represented by malformed phalanges, scoliosis, abnormal modeling of vertebral bodies, hip dislocation, abnormal acetabula, feet anomalies, and delayed neuropsychological development. Deletions reported in this region are clinically heterogeneous, ranging from subtle phenotypic manifestations to severe congenital heart defects and/or neurodevelopmental findings. A few genes within the deleted region are associated with congenital anomalies, mainly the RBM8A , DUF1220 , and HYDIN2 paralogs. Our patient presents with a spectrum of unusual malformations of 1q21.1 deletion syndrome not reported up to date.
Gamba, Bruno F.; Zechi-Ceide, Roseli M.; Kokitsu-Nakata, Nancy M.; Vendramini-Pittoli, Siulan; Rosenberg, Carla; Krepischi Santos, Ana C.V.; Ribeiro-Bicudo, Lucilene; Richieri-Costa, Antonio
2016-01-01
We report on a Brazilian patient with a 1.7-Mb interstitial microdeletion in chromosome 1q21.1. The phenotypic characteristics include microcephaly, a peculiar facial gestalt, cleft lip/palate, and multiple skeletal anomalies represented by malformed phalanges, scoliosis, abnormal modeling of vertebral bodies, hip dislocation, abnormal acetabula, feet anomalies, and delayed neuropsychological development. Deletions reported in this region are clinically heterogeneous, ranging from subtle phenotypic manifestations to severe congenital heart defects and/or neurodevelopmental findings. A few genes within the deleted region are associated with congenital anomalies, mainly the RBM8A, DUF1220, and HYDIN2 paralogs. Our patient presents with a spectrum of unusual malformations of 1q21.1 deletion syndrome not reported up to date. PMID:27920638
Dynamic Grain Growth in Forsterite Aggregates Experimentally Deformed to High Strain
NASA Astrophysics Data System (ADS)
Kellermann Slotemaker, A.; de Bresser, H.; Spiers, C.; Drury, M.
2004-12-01
The dynamics of the outer Earth are largely controlled by olivine rheology. From previous work it has become clear that if olivine rocks are deformed to high strain, substantial weakening may occur before steady state mechanical behaviour is approached. This weakening appears directly related to progressive modification of the grain size distribution through competing effects of dynamic recrystallization and syn-deformational grain growth. However, most of our understanding of these processes in olivine comes from tests on coarse-grained materials that were reduced in grain size during straining by grain size insensitive (dislocation) creep mechanisms. The aim of the present study was to investigate microstructure evolution of fine-grained olivine rocks that coarsen in grain size while deforming by grain size sensitive (GSS) creep. We used fine-grained (~1 μ m) olivine aggregates (i.e., forsterite/Mg2SiO4), containing ~0.5 wt% water and 10 vol% enstatite (MgSiO3). Two types of experiments were carried out: 1) Hot isostatic pressing (HIP) followed by axial compression to varying strains up to a maximum of ~45%, at 600 MPa confining pressure and a temperature of 950°C, 2) HIP treatment without axial deformation. Microstructures were characterized by analyzing full grain size distributions and texture using SEM/EBSD. Our stress-strain curves showed continuous hardening. When samples were temporally unloaded for short time intervals, no difference in flow stress was observed before and after the interruption in straining. Strain rate sensitivity analysis showed a low value of ~1.5 for the stress exponent n. Measured grain sizes show an increase with strain up to a value twice that of the starting value. HIP-only samples showed only minor increase in grain size. A random LPO combined with the low n ~1.5 suggests dominant GSS creep controlled by grain boundary sliding. These results indicate that dynamic grain growth occurs in forsterite aggregates deforming by GSS creep, and we relate the continuous strain hardening to this process. A dynamic grain growth model involving an increase in cellular defect fraction seems best applicable to the grain growth observed in this study. We suggest that the employment of this model to fine-grained olivine rocks can further improve our understanding of the microstructural evolution of this material and related rheological behaviour.
Migaud, Henri; Putman, Sophie; Kern, Grégory; Isida, Ronald; Girard, Julien; Ramdane, Nassima; Delaunay, Christian P; Hamadouche, Moussa
2016-10-01
Despite widespread use of ceramic-on-ceramic (CoC) in total hip arthroplasty (THA) during the past 10 years, little is known about why revisions are performed in hips with this bearing or the time elapsed before revision. The purposes of this study were: (1) Do the reasons for first revision differ between CoC bearings and other bearing couples? (2) Does the time to revision differ between CoC and other bearing couples? (3) Are there unique reasons for revisions of CoC bearings? All members of the Société Française de Chirurgie Orthopédique et Traumatologique (SoFCOT) who performed ≥ 30 revisions per year were invited to participate in this multicenter, prospective, observational study. Our data represent 12% of the revision procedures performed in France. A total of 2107 first revisions of THA (from January 2010 to December 2011) were done in 2107 patients (1201 females [57%] and 906 males [43%]; median age, 73 years; age range, 17-104 years) at the time of surgery after a median of 11 years (range, 0 day-42 years) after the primary THA. There were 238 of 2107 (11%) CoC, 148 of 2107 (7%) metal-on-metal (MoM), and 1721 of 2017 (82%) metal-on-polyethylene (MoP) bearings. The reasons for reoperation differed according to the bearing component: (1) for the MoP reference bearing (odds ratio [OR]; 95% confidence interval), cup loosening occurred in 698 of 1721 hips (41%), periprosthetic fracture in 220 of 1721 hips (13%), and osteolysis in 213 of 1721 hips (12%); (2) for CoC, cup loosening occurred in 41 of 238 hips (17%) (OR, 0.31 [0.22-0.43; p < 0.001), infection in 39 of 238 hips (16%) (OR, 1.63 [1.12-2.37]; p = 0.01), and dislocation in 23 of 238 hips (10%) (OR, 0.9 [0.57-1.42]; p = 0.9); (3) for MoM, cup loosening occurred in 28 of 148 hips (19%) (OR, 0.34 [0.22-0.52]; p < 0.001), adverse reaction to metallic debris in 26 of 148 hips (18%) (OR, 18.12 [9.84-33.4]; p < 0.001), and infection in 16 of 148 hips (11%) (OR, 1 [0.59-1.73]; p = 0.9). In comparison with MoP, osteolysis was rarely the reason for revision in CoC (four of 238 hips [2%]; OR, 0.12 [0.05-0.33]; p < 0.001), but this bearing was frequently revised because of iliopsoas irritation (18 of 238 hips [8%]; OR, 4.9 [2.7-9]; p < 0.001). The time elapsed before revision differed between bearings: median of 3 years (range, 3 days to 28 years) for CoC and 4 years (range, 14 days to 37 years) for MoM versus a median 13 years (range, 0 day to 42 years) for MoP (p < 0.001). Thirty-seven of the 238 revisions (16%) were directly related to ceramic use (ceramic breakage [n = 23], squeaking [n = 6], impingement [n = 7], incorrect ceramic insert insertion [n = 1]). No factors were identified that contributed to breakage of the 12 bulk ceramic components (eight heads, four inserts, four of 12 Delta ceramic). No factors were associated with squeaking, iliopsoas irritation, or impingement, but component orientation was not assessed. The reasons and time to first revision differed between CoC and other bearings. CoC THAs are revised earlier and are sensitive to mechanical problems such as impingement, squeaking, and ceramic rupture that did not disappear with introduction of Delta ceramics and large-diameter (≥ 36 mm) bearings. CoC was rarely revised for osteolysis, but a high rate of iliopsoas irritation requires further investigation. Level III, therapeutic study.
Hominin Hip Biomechanics: Changing Perspectives.
Warrener, Anna G
2017-05-01
The shape of the human pelvis reflects the unique demands placed on the hip abductor muscles (gluteus medius and gluteus minimus), which stabilize the body in the frontal plane during bipedal locomotion. This morphological shift occurred early in hominin evolution, yet important shape differences between hominin species have led to significant disagreement about abductor function and locomotor capability in these extinct taxa. A static biomechanical model that relies on a close association between skeletal measurements of the pelvis and femur has traditionally been used to reconstruct hip biomechanics in these species. However, experimental biomechanical approaches have highlighted the dynamic nature of mediolateral balance in walking and running, challenging the assumptions of the static hip model. This article reviews traditional approaches for understanding hip abductor function, shows how they have been applied to the fossil hominin record, and discusses new techniques that integrate the dynamic nature of mediolateral balance during human locomotion. Anat Rec, 300:932-945, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Improved Hip-Based Individual Recognition Using Wearable Motion Recording Sensor
NASA Astrophysics Data System (ADS)
Gafurov, Davrondzhon; Bours, Patrick
In todays society the demand for reliable verification of a user identity is increasing. Although biometric technologies based on fingerprint or iris can provide accurate and reliable recognition performance, they are inconvenient for periodic or frequent re-verification. In this paper we propose a hip-based user recognition method which can be suitable for implicit and periodic re-verification of the identity. In our approach we use a wearable accelerometer sensor attached to the hip of the person, and then the measured hip motion signal is analysed for identity verification purposes. The main analyses steps consists of detecting gait cycles in the signal and matching two sets of detected gait cycles. Evaluating the approach on a hip data set consisting of 400 gait sequences (samples) from 100 subjects, we obtained equal error rate (EER) of 7.5% and identification rate at rank 1 was 81.4%. These numbers are improvements by 37.5% and 11.2% respectively of the previous study using the same data set.
Dislocation loop evolution during in-situ ion irradiation of model FeCrAl alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haley, Jack C.; Briggs, Samuel A.; Edmondson, Philip D.
Model FeCrAl alloys of Fe-10%Cr-5%Al, Fe-12%Cr-4.5%Al, Fe-15%Cr-4%Al, and Fe-18%Cr-3%Al (in wt %) were irradiated with 1 MeV Kr++ ions in-situ with transmission electron microscopy to a dose of 2.5 displacements per atom (dpa) at 320 °C. In all cases, the microstructural damage consisted of dislocation loops with ½< 111 > and <100 > Burgers vectors. The proportion of ½< 111 > dislocation loops varied from ~50% in the Fe-10%Cr-5%Al model alloy and the Fe-18Cr%-3%Al model alloy to a peak of ~80% in the model Fe-15%Cr-4.5%Al alloy. The dislocation loop volume density increased with dose for all alloys and showed signsmore » of approaching an upper limit. The total loop populations at 2.5 dpa had a slight (and possibly insignificant) decline as the chromium content was increased from 10 to 15 wt %, but the Fe-18%Cr-3%Al alloy had a dislocation loop population ~50% smaller than the other model alloys. As a result, the largest dislocation loops in each alloy had image sizes of close to 20 nm in the micrographs, and the median diameters for all alloys ranged from 6 to 8 nm. Nature analysis by the inside-outside method indicated most dislocation loops were interstitial type.« less
Fischer, N; Pinggera, L; Weichbold, V; Dejaco, D; Schmutzhard, J; Widmann, G
2015-02-01
Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and to evaluate its influence on auditory outcome. This retrospective single-center study analyzed a consecutive series of 63 cochlear implantations with various straight electrodes. The placement of the electrode array was evaluated by using multiplanar reconstructed conebeam CT images. For the auditory outcome, we compared the aided hearing thresholds and the charge units of maximum comfortable loudness level at weeks 6, 12, and 24 after implantation. In 7.9% of the cases, the electrode array showed scalar dislocation. In all cases, the electrode array penetrated the basal membrane within 45° of the electrode insertion. All 3 cases of cochleostomy were dislocated in the first 45° segment. No hearing differences were noted, but the charge units of maximum comfortable loudness level seemed to increase with time in patients with dislocations. The intracochlear dislocation rate of various straight electrodes detected by conebeam CT images is relatively low. Scalar dislocation may not negatively influence the hearing threshold but may require an increase of the necessary stimulus charge and should be reported by the radiologist. © 2015 by American Journal of Neuroradiology.
Dislocation loop evolution during in-situ ion irradiation of model FeCrAl alloys
Haley, Jack C.; Briggs, Samuel A.; Edmondson, Philip D.; ...
2017-07-06
Model FeCrAl alloys of Fe-10%Cr-5%Al, Fe-12%Cr-4.5%Al, Fe-15%Cr-4%Al, and Fe-18%Cr-3%Al (in wt %) were irradiated with 1 MeV Kr++ ions in-situ with transmission electron microscopy to a dose of 2.5 displacements per atom (dpa) at 320 °C. In all cases, the microstructural damage consisted of dislocation loops with ½< 111 > and <100 > Burgers vectors. The proportion of ½< 111 > dislocation loops varied from ~50% in the Fe-10%Cr-5%Al model alloy and the Fe-18Cr%-3%Al model alloy to a peak of ~80% in the model Fe-15%Cr-4.5%Al alloy. The dislocation loop volume density increased with dose for all alloys and showed signsmore » of approaching an upper limit. The total loop populations at 2.5 dpa had a slight (and possibly insignificant) decline as the chromium content was increased from 10 to 15 wt %, but the Fe-18%Cr-3%Al alloy had a dislocation loop population ~50% smaller than the other model alloys. As a result, the largest dislocation loops in each alloy had image sizes of close to 20 nm in the micrographs, and the median diameters for all alloys ranged from 6 to 8 nm. Nature analysis by the inside-outside method indicated most dislocation loops were interstitial type.« less
Effects of Plasma Hydrogenation on Trapping Properties of Dislocations in Heteroepitaxial InP/GaAs
NASA Technical Reports Server (NTRS)
Ringel, S. A.; Chatterjee, B.
1994-01-01
In previous work, we have demonstrated the effectiveness of a post-growth hydrogen plasma treatment for passivating the electrical activity of dislocations in metalorganic chemical vapor deposition (MOCVD) grown InP on GaAs substrates by a more than two order of magnitude reduction in deep level concentration and an improvement in reverse bias leakage current by a factor of approx. 20. These results make plasma hydrogenation an extremely promising technique for achieving high efficiency large area and light weight heteroepitaxial InP solar cells for space applications. In this work we investigate the carrier trapping process by dislocations in heteroepitaxial InP/GaAs and the role of hydrogen passivation on this process. It is shown that the charge trapping kinetics of dislocations after hydrogen passivation are significantly altered, approaching point defect-like behavior consistent with a transformation from a high concentration of dislocation-related defect bands within the InP bandgap to a low concentration of individual deep levels after hydrogen passivation. It is further shown that the "apparent" activation energies of dislocation related deep levels, before and after passivation, reduce by approx. 70 meV as DLTS fill pulse times are increased from 1 usec. to 1 msec. A model is proposed which explains these effects based on a reduction of Coulombic interaction between individual core sites along the dislocation cores by hydrogen incorporation. Knowledge of the trapping properties in these specific structures is important to develop optimum, low loss heteroepitaxial InP cells.
Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi
2016-03-01
The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p < 0.0001). Major complications included a marked elevation in intraocular pressure (7.8 %), pupillary capture (6.5 %), and vitreous hemorrhage (2.6 %). Based on the classification system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.
Crimp, Martin A
2006-05-01
The imaging and characterization of dislocations is commonly carried out by thin foil transmission electron microscopy (TEM) using diffraction contrast imaging. However, the thin foil approach is limited by difficult sample preparation, thin foil artifacts, relatively small viewable areas, and constraints on carrying out in situ studies. Electron channeling imaging of electron channeling contrast imaging (ECCI) offers an alternative approach for imaging crystalline defects, including dislocations. Because ECCI is carried out with field emission gun scanning electron microscope (FEG-SEM) using bulk specimens, many of the limitations of TEM thin foil analysis are overcome. This paper outlines the development of electron channeling patterns and channeling imaging to the current state of the art. The experimental parameters and set up necessary to carry out routine channeling imaging are reviewed. A number of examples that illustrate some of the advantages of ECCI over thin foil TEM are presented along with a discussion of some of the limitations on carrying out channeling contrast analysis of defect structures. Copyright (c) 2006 Wiley-Liss, Inc.
A continuum dislocation dynamics framework for plasticity of polycrystalline materials
NASA Astrophysics Data System (ADS)
Askari, Hesam Aldin
The objective of this research is to investigate the mechanical response of polycrystals in different settings to identify the mechanisms that give rise to specific response observed in the deformation process. Particularly the large deformation of magnesium alloys and yield properties of copper in small scales are investigated. We develop a continuum dislocation dynamics framework based on dislocation mechanisms and interaction laws and implement this formulation in a viscoplastic self-consistent scheme to obtain the mechanical response in a polycrystalline system. The versatility of this method allows various applications in the study of problems involving large deformation, study of microstructure and its evolution, superplasticity, study of size effect in polycrystals and stochastic plasticity. The findings from the numerical solution are compared to the experimental results to validate the simulation results. We apply this framework to study the deformation mechanisms in magnesium alloys at moderate to fast strain rates and room temperature to 450 °C. Experiments for the same range of strain rates and temperatures were carried out to obtain the mechanical and material properties, and to compare with the numerical results. The numerical approach for magnesium is divided into four main steps; 1) room temperature unidirectional loading 2) high temperature deformation without grain boundary sliding 3) high temperature with grain boundary sliding mechanism 4) room temperature cyclic loading. We demonstrate the capability of our modeling approach in prediction of mechanical properties and texture evolution and discuss the improvement obtained by using the continuum dislocation dynamics method. The framework was also applied to nano-sized copper polycrystals to study the yield properties at small scales and address the observed yield scatter. By combining our developed method with a Monte Carlo simulation approach, the stochastic plasticity at small length scales was studied and the sources of the uncertainty in the polycrystalline structure are discussed. Our results suggest that the stochastic response is mainly because of a) stochastic plasticity due to dislocation substructure inside crystals and b) the microstructure of the polycrystalline material. The extent of the uncertainty is correlated to the "effective cell length" in the sampling procedure whether using simulations and experimental approach.
Surgical Approaches to the Proximal Interphalangeal Joint.
Cheah, Andre Eu-Jin; Yao, Jeffrey
2016-02-01
The proximal interphalangeal (PIP) joint may be affected by many conditions such as arthropathy, fractures, dislocations, and malunions. Whereas some of these conditions may be treated nonsurgically, many require open surgical intervention. Open interventions include implant arthroplasty or arthrodesis for arthropathy, open reduction internal fixation, or hemi-hamate arthroplasty for dorsal fracture-dislocations. Volar plate arthroplasty and corrective osteotomy for malunion about the PIP joint are also surgeries that may be required. The traditional approach to the PIP joint has been dorsal, which damages the delicate extensor apparatus with subsequent development of an extensor lag. This has led surgeons to explore volar and lateral approaches to the PIP joint. In this article, we describe each of these surgical approaches, discuss their advantages and disadvantages, and provide some guidance on which approach to choose based on the surgery that is to be performed. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Nistor, Dan-Viorel; Caterev, Sergiu; Bolboacă, Sorana-Daniela; Cosma, Dan; Lucaciu, Dan Osvald Gheorghe; Todor, Adrian
2017-11-01
We conducted this study to establish if the transition from a lateral approach (LA) to the direct anterior approach (DAA) for a low volume hip arthroplasty surgeon during the steep learning curve can be performed maintaining the muscle sparing approach of the DAA without increasing the complication rates. In this controlled, prospective, randomized clinical study we investigated 70 patients (35 DAA, 35 LA) with similar demographics that underwent a total hip arthroplasty. Assessment of the two approaches consisted of determining the invasiveness through serum markers for muscle damage (i.e. myoglobin, creatine kinase and lactate dehydrogenase), the operative parameters such as post-operative pain and rescue medication consumption, the component positioning and complication rates. Post-operative myoglobin levels were higher (p < 0.001) in the LA group (326.42 ± 84.91 ng/mL) as compared to the DAA group (242.80 ± 71.03 ng/mL), but with no differences regarding other biomarkers for muscle damage. Pain levels were overall lower in the DAA group, with a statistical and clinical difference during surgery day (p < 0.001) associated with lower (p < 0.001) rescue medication consumption (median 1 (1; 3) mg morphine vs. 3 (2; 4) mg morphine). Most patients in the LA group reported chronic post-operative pain throughout all three evaluated months, while the majority of patients in the DAA group reported no pain after week six. Component positioning did not differ significantly between groups and neither did complication rates. The DAA can be transitioned from the LA safely, without higher complication rates while maintaining its muscle spearing advantages when performed by a low volume hip arthroplasty surgeon.
Du, Wei; Wang, Cheng; Tan, Jiangwei; Shen, Binghua; Ni, Shuqin; Zheng, Yanping
2014-01-01
Retrospective case series. To discuss the clinical efficacy of anterior cervical surgery of decompression, reduction, stabilization, and fusion in treating subaxial cervical facet dislocation without spinal cord injury or with mild spinal cord injury monitored by spinal cord evoked potential. The optimal treatment of lower cervical facet dislocation has been controversial. Because of the risk of iatrogenic damage of neurological function, it is challenging for surgeons to manage the lower cervical facet dislocation without or with mild spinal cord injury. To avoid the risks, more secure strategy need to be designed. A retrospective study was performed on 17 cases of subaxial cervical facet dislocation without spinal cord injury or with mild spinal cord injury treated by anterior cervical surgery under spinal cord evoked potential monitor from January 2008 to June 2012. There were 12 males, 5 females, with a mean age of 40.1 years (from 21 to 73 yr). Dislocation sites: 1 in C3-C4, 2 in C4-C5, 6 in C5-C6, 8 in C6-C7; 10 cases with unilateral cervical facet dislocation, 7 cases with bilateral dislocation. Thirteen patients were preoperatively classified as grade D and 4 as E according to Frankel standard. All patients were followed up for average of 16 months. All operations were completed successfully. Postoperative radiographs showed that the sequence and curvature of the cervical spine were well recovered. And, evidence of intervertebral fusion was observed at 3 months in all cases. No redislocation or symptoms of spinal cord injury occurred. Thirteen cases with mild spinal cord injury recovered at 1 month after operation. Anterior cervical surgery of decompression, reduction, stabilization, and fusion monitored by spinal cord evoked potential is an effective and safe method for treatment of subaxial cervical facet dislocation without or with mild spinal cord injury. 4.
Sienkiewicz, Waldemar; Dudek, Agnieszka; Czaja, Krzysztof; Janeczek, Maciej; Chrószcz, Aleksander; Kaleczyc, Jerzy
2018-01-01
Objective To evaluate efficacy of denervation of the of the hip joint capsule (HJC), as a treatment of hip joint pain. Specifically, we tested the hypothesis that HJC denervation will significantly reduce the number of sensory neurons innervating the capsule. Study design Denervation of the HJC from a medial or lateral approach was followed by retrograde tracing of sensory neurons innervating the capsule. Animals Twenty adult male sheep (30–40 kg of body weight; Polish merino breed) were used in the study. Methods The hip joint was denervated from medial (n = 5) or lateral (n = 5) surgical approaches. Immediately after denervation, the retrograde neural tract tracer Fast Blue (FB) was injected into the HJC. An additional ten animals (n = 5 for medial and n = 5 for lateral approach) received the same treatment without HJC denervation to provide the appropriate controls. Results Results of the study revealed that the vast majority of retrogradely labelled sensory neurons innervating the HJC originate from fifth lumbar to second sacral dorsal root ganglia. Both the medial and the lateral denervations significantly reduced the number of sensory neurons innervating the HJC (39.2% and 69.0% reduction respectively). Conclusions These results show that denervation of the HJC is an effective surgical procedure for reduction of the sensory neuronal input to the HJC. Moreover, the lateral approach was found to be significantly more effective for reducing sensory innervation as compared to the medial one. PMID:29329303
Towards Subject-Specific Strength Training Design through Predictive Use of Musculoskeletal Models.
Plüss, Michael; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio
2018-01-01
Lower extremity dysfunction is often associated with hip muscle strength deficiencies. Detailed knowledge of the muscle forces generated in the hip under specific external loading conditions enables specific structures to be trained. The aim of this study was to find the most effective movement type and loading direction to enable the training of specific parts of the hip muscles using a standing posture and a pulley system. In a novel approach to release the predictive power of musculoskeletal modelling techniques based on inverse dynamics, flexion/extension and ab-/adduction movements were virtually created. To demonstrate the effectiveness of this approach, three hip orientations and an external loading force that was systematically rotated around the body were simulated using a state-of-the art OpenSim model in order to establish ideal designs for training of the anterior and posterior parts of the M. gluteus medius (GM). The external force direction as well as the hip orientation greatly influenced the muscle forces in the different parts of the GM. No setting was found for simultaneous training of the anterior and posterior parts with a muscle force higher than 50% of the maximum. Importantly, this study has demonstrated the use of musculoskeletal models as an approach to predict muscle force variations for different strength and rehabilitation exercise variations.
Towards Subject-Specific Strength Training Design through Predictive Use of Musculoskeletal Models
Plüss, Michael; Schellenberg, Florian
2018-01-01
Lower extremity dysfunction is often associated with hip muscle strength deficiencies. Detailed knowledge of the muscle forces generated in the hip under specific external loading conditions enables specific structures to be trained. The aim of this study was to find the most effective movement type and loading direction to enable the training of specific parts of the hip muscles using a standing posture and a pulley system. In a novel approach to release the predictive power of musculoskeletal modelling techniques based on inverse dynamics, flexion/extension and ab-/adduction movements were virtually created. To demonstrate the effectiveness of this approach, three hip orientations and an external loading force that was systematically rotated around the body were simulated using a state-of-the art OpenSim model in order to establish ideal designs for training of the anterior and posterior parts of the M. gluteus medius (GM). The external force direction as well as the hip orientation greatly influenced the muscle forces in the different parts of the GM. No setting was found for simultaneous training of the anterior and posterior parts with a muscle force higher than 50% of the maximum. Importantly, this study has demonstrated the use of musculoskeletal models as an approach to predict muscle force variations for different strength and rehabilitation exercise variations. PMID:29796082
Canadian academic experience with metal-on-metal hip resurfacing.
O'Neill, Michelle; Beaule, Paul E; Bin Nasser, Ahmad; Garbuz, Donald; Lavigne, Martin; Duncan, Clive; Kim, Paul R; Schemitsch, Emil
2009-01-01
The current depth and breadth of experience in hip resurfacing in Canadian academic centers is not well known. This study endeavors to increase awareness of the prevalence of programs and current experience in a select number of representative teaching centers by examining the learning curve of high-volume surgeons. A questionnaire was sent to all academic centers in Canada to identify the volume of hip resurfacing, surgical approach, and type of prosthesis. In addition, five surgeons, not fellowship-trained in hip resurfacing, were selected for a detailed review of their first 50 cases, including survey of patient demographics, surgical approach, radiographic evaluation, complications, and revision. Eleven of 14 academic centers are currently performing hip resurfacing. All of these centers had performed more than 50 cases, with 10 of 11 of them having more than one surgeon performing the procedure. The posterior approach was found to be the most commonly utilized in surgeries. The overall revision rate was 3.2% at a mean time of 2 years, with femoral neck fracture (1.6%) being the most common cause for failure. The failure rate was comparable to other centers of expertise and lower than previously published multicenter trials. All surgeons reviewed were in specialized arthroplasty practices, which may contribute to the relatively low complication rates reported.
Tendon Disorders After Total Hip Arthroplasty: Evaluation and Management.
Capogna, Brian M; Shenoy, Kartik; Youm, Thomas; Stuchin, Steven A
2017-10-01
Most patients who undergo total hip arthroplasty are very satisfied with their outcomes. However, there is a small subset of patients who have persistent pain after surgery. The etiology of pain after total hip arthroplasty varies widely; however, tendon disorders are a major cause of debilitating pain that often go unrecognized. We performed a literature review to identify the most common tendon pathologies after total hip arthroplasty which include iliopsoas tendinitis, greater trochanteric pain syndrome, snapping hip syndrome, and abductor tendinopathy. We present a simplified approach highlighting the presentation and management of patients with suspected tendinopathies after total hip arthroplasty. These tendinopathies are treatable, and management begins with nonoperative modalities; however, in cases not responsive to conservative management, operative intervention may be necessary. Tendinopathies after total hip arthroplasty sometimes go unrecognized but when treated can result in higher surgeon and patient satisfaction. Copyright © 2017 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Turner, K. C. Nat; Hayes, Nini, Visaya; Way, Kate
2013-01-01
This article features key findings from a study that highlights the transformative impact of a pedagogical approach that employs Critical Multimodal Hip Hop Production (CMHHP). The study took place in an extended day program in a northern California public middle school among a group of 30, urban, African American, Chicano/a/Latino/a, and Asian…
Understanding Solidification Based Grain Refinement in Steels
2014-12-18
sulfide.^^"^^ Another approach would be to react a sample of misch metal or rare earth silicide at elevated temperatures to form the desired oxide or...dislocation can travel through a metal crystal before being blocked by a grain boundary. Since the dislocation is impeded sooner, the material cannot...in the melt; 3) be wetted by the liquid metal ; and 4) have a similar crystallographic structure to the host metal . Using reference data and
Lumbo-Pelvic-Hip Complex Pain in a Competitive Basketball Player
Reiman, Michael P.; Cox, Kara D.; Jones, Kay S.; Byrd, J. W.
2011-01-01
Establishing the cause of lumbo-pelvic-hip complex pain is a challenge for many clinicians. This case report describes the mechanism of injury, diagnostic process, surgical management, and rehabilitation of a female high school basketball athlete who sustained an injury when falling on her right side. Diagnostics included clinical examination, radiography of the spine and hip joint, magnetic resonance imaging arthrogram, 3-dimensional computed tomography scan, and computed tomography of the hip joint. A systematic multidisciplinary clinical approach resulted in the patient’s return to previous functional levels. PMID:23015993
Ollivier, M; Frey, S; Parratte, S; Flecher, X; Argenson, J N
2014-08-01
There is little in the literature on the level of participation in sports which patients undertake after total hip replacement (THR). Our aims in this study were to determine first, the level of sporting activity, second, the predictive factors for returning to sporting activity, and third, the correlation between participation in sports and satisfaction after THR. We retrospectively identified 815 patients who had undergone THR between 1995 and 2005. All were asked to complete a self-administered questionnaire regarding their sporting activity. A total of 571 patients (71%) met the inclusion criteria and completed the evaluation. At a mean follow-up of 9.8 years (sd 2.9), 366 patients (64%) returned to sporting activity as defined by a University of California at Los Angeles (UCLA) score of > 5. The main reasons that patients had for refraining from sports were fear of dislocation (65; 31.6%), avoiding wear (52; 25.4%), and the recommendation of the surgeon (34; 16.6%). There was a significant relationship between higher post-operative participation in sport in those patients with a higher pre-operative Harris hip score (HHS) (p = 0.0074), motivation to participate in sporting activities (p = 0.00022) and a shorter duration of symptoms (p = 0.0034). Finally, there was a correlation between age (p = 0.00013), UCLA score (p = 0.012) and pre-operative HHS (p = 0.00091) and satisfaction. In conclusion, we found that most patients participate in sporting activity after THR, regardless of the advice of their surgeon, and that there is a correlation between the level of participation and pre-operative function, motivation, duration of symptoms and post-operative satisfaction. ©2014 The British Editorial Society of Bone & Joint Surgery.
Treatment of aneurysmal bone cysts of the pelvis and sacrum.
Papagelopoulos, P J; Choudhury, S N; Frassica, F J; Bond, J R; Unni, K K; Sim, F H
2001-11-01
Aneurysmal bone cysts are benign, non-neoplastic, highly vascular bone lesions. The purpose of this study was to describe the prevalence, the clinical presentation, and the recurrence rate of aneurysmal bone cysts of the pelvis and sacrum and to examine the diagnostic and therapeutic options and prognosis for patients with this condition. Forty consecutive patients with an aneurysmal bone cyst of the pelvis and/or sacrum were treated from 1921 to 1996. Their medical records and radiographic and imaging studies were reviewed, and histological sections from the cysts were examined. Seventeen lesions were iliosacral, sixteen were acetabular, and seven were ischiopubic. Seven involved the hip joint, and two involved the sacroiliac joint. All twelve sacral lesions extended to more than one sacral segment and were associated with neurological signs and symptoms. Destructive acetabular lesions were associated with pathological fracture in five patients and with medial migration of the femoral head, hip subluxation, and hip dislocation in one patient each. The mean duration of follow-up was thirteen years (range, three to fifty-three years). Thirty-five patients who were initially treated for a primary lesion had surgical treatment (twenty-one had excision-curettage and fourteen had intralesional excision); two patients also had adjuvant radiation therapy. Of the thirty-five patients, five (14%) had a local recurrence noted less than eighteen months after the operation. Of five patients initially treated for a recurrent lesion, one had a local recurrence. At the latest follow-up examination, all forty patients were disease-free and twenty-eight (70%) were asymptomatic. There were two deep infections. Aneurysmal bone cysts of the pelvis and sacrum are usually aggressive lesions associated with substantial bone destruction, pathological fractures, and local recurrence. Current management recommendations include preoperative selective arterial embolization, excision-curettage, and bone-grafting.
Mellon, Stephen J; Grammatopoulos, George; Andersen, Michael S; Pandit, Hemant G; Gill, Harinderjit S; Murray, David W
2015-01-21
Edge-loading in patients with metal-on-metal resurfaced hips can cause high serum metal ion levels, the development of soft-tissue reactions local to the joint called pseudotumours and ultimately, failure of the implant. Primary edge-loading is where contact between the femoral and acetabular components occurs at the edge/rim of the acetabular component whereas impingement of the femoral neck on the acetabular component's edge causes secondary or contrecoup edge-loading. Although the relationship between the orientation of the acetabular component and primary edge-loading has been identified, the contribution of acetabular component orientation to impingement and secondary edge-loading is less clear. Our aim was to estimate the optimal acetabular component orientation for 16 metal-on-metal hip resurfacing arthroplasty (MoMHRA) subjects with known serum metal ion levels. Data from motion analysis, subject-specific musculoskeletal modelling and Computed Tomography (CT) measurements were used to calculate the dynamic contact patch to rim (CPR) distance and impingement risk for 3416 different acetabular component orientations during gait, sit-to-stand, stair descent and static standing. For each subject, safe zones free from impingement and edge-loading (CPR <10%) were defined and, consequently, an optimal acetabular component orientation was determined (mean inclination 39.7° (SD 6.6°) mean anteversion 14.9° (SD 9.0°)). The results of this study suggest that the optimal acetabular component orientation can be determined from a patient's motion and anatomy. However, 'safe' zones of acetabular component orientation associated with reduced risk of dislocation and pseudotumour are also associated with a reduced risk of edge-loading and impingement. Copyright © 2014 Elsevier Ltd. All rights reserved.
Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.
Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2009-12-01
Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.
Arliani, Gustavo Gonçalves; Utino, Artur Yudi; Nishimura, Eduardo Misao; Terra, Bernardo Barcellos; Belangero, Paulo Santoro; Astur, Diego Costa
2015-01-01
Objective To evaluate the approaches and procedures used by Brazilian orthopedic surgeons in treatment and rehabilitation of acromioclavicular dislocation of the shoulder. Methods A questionnaire comprising eight closed questions that addressed topics relating to treatment and rehabilitation of acromioclavicular dislocation was applied to Brazilian orthopedic surgeons over the three days of the 45th Brazilian Congress of Orthopedics and Traumatology, in 2013. Results A total of 122 surgeons completely filled out the questionnaire and formed part of the sample analyzed. Most of them came from the southeastern region of the country. In this sample, 67% of the participants would choose surgical treatment for patients with grade 3 acromioclavicular dislocation. Regarding the preferred technique for surgical treatment of acute acromioclavicular dislocation, a majority of the surgeons used subcoracoid ligature with acromioclavicular fixation and transfer of the coracoacromial ligament (25.4%). Regarding complications found after surgery had been performed, 43.4% and 32.8% of the participants, respectively, stated that residual deformity of the operated joint and pain were the complications most seen during the postoperative period. Conclusions Although there was no consensus regarding the treatment and rehabilitation of acromioclavicular dislocation, evolution had occurred in some of the topics analyzed in this questionnaire applied to Brazilian orthopedists. However, further controlled prospective studies are needed in order to evaluate the clinical and scientific benefit of these trends. PMID:26535196
Arliani, Gustavo Gonçalves; Utino, Artur Yudi; Nishimura, Eduardo Misao; Terra, Bernardo Barcellos; Belangero, Paulo Santoro; Astur, Diego Costa
2015-01-01
To evaluate the approaches and procedures used by Brazilian orthopedic surgeons in treatment and rehabilitation of acromioclavicular dislocation of the shoulder. A questionnaire comprising eight closed questions that addressed topics relating to treatment and rehabilitation of acromioclavicular dislocation was applied to Brazilian orthopedic surgeons over the three days of the 45th Brazilian Congress of Orthopedics and Traumatology, in 2013. A total of 122 surgeons completely filled out the questionnaire and formed part of the sample analyzed. Most of them came from the southeastern region of the country. In this sample, 67% of the participants would choose surgical treatment for patients with grade 3 acromioclavicular dislocation. Regarding the preferred technique for surgical treatment of acute acromioclavicular dislocation, a majority of the surgeons used subcoracoid ligature with acromioclavicular fixation and transfer of the coracoacromial ligament (25.4%). Regarding complications found after surgery had been performed, 43.4% and 32.8% of the participants, respectively, stated that residual deformity of the operated joint and pain were the complications most seen during the postoperative period. Although there was no consensus regarding the treatment and rehabilitation of acromioclavicular dislocation, evolution had occurred in some of the topics analyzed in this questionnaire applied to Brazilian orthopedists. However, further controlled prospective studies are needed in order to evaluate the clinical and scientific benefit of these trends.
Longo, Umile Giuseppe; Ciuffreda, Mauro; Rizzello, Giacomo; Mannering, Nicholas; Maffulli, Nicola; Denaro, Vincenzo
2017-06-01
The management of Type III acromioclavicular (AC) dislocations is still controversial. We wished to compare the rate of recurrence and outcome scores of operative versus non-operative treatment of patients with Type III AC dislocations. A systematic review of the literature was performed by applying the PRISMA guidelines according to the PRISMA checklist and algorithm. A search in Medline, PubMed, Cochrane and CINAHL was performed using combinations of the following keywords: 'dislocation', 'Rockwood', 'type three', 'treatment', 'acromioclavicular' and 'joint'. Fourteen studies were included, evaluating 646 shoulders. The rate of recurrence in the surgical group was 14%. No statistical significant differences were found between conservative and surgical approaches in terms of postoperative osteoarthritis and persistence of pain, although persistence of pain seemed to occur less frequently in patients undergoing a surgical treatment. Persistence of pain seemed to occur less frequently in patients undergoing surgery. Persistence of pain seems to occur less frequently in patients treated surgically for a Type III AC dislocation. There is insufficient evidence to establish the effects of surgical versus conservative treatment on functional outcome of patients with AC dislocation. High-quality randomized controlled clinical trials are needed to establish whether there is a difference in functional outcome. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Spiker, Andrea M; Gumersell, Kate R; Sink, Ernest L; Kelly, Bryan T
2017-10-01
In the realm of hip preservation, hip arthroscopy is often used to address intra-articular impingement pathology, whereas periacetabular osteotomy (PAO) is used to address dysplasia and instability. Indications to combine these 2 procedures include hip dysplasia and symptomatic instability with a concomitant symptomatic labral tear or the other symptomatic intra-articular pathology (i.e., loose body, chondral flap). The arthroscopic portion of the procedure allows repair of the injured labrum and close inspection of the hip joint, and the PAO addresses undercoverage and/or inappropriate version of the acetabulum. The open approach used in PAO also allows access to the peripheral compartment to debride a cam lesion, if present, and the subspine region is accessible to perform subspine decompression, if needed. In this technique, we highlight special considerations pertaining to hip arthroscopy that is performed in combination with a PAO. Hip arthroscopy is the first procedure that takes place in this combined case, and modifications to the standard hip arthroscopic technique can prevent unnecessary difficulty during the PAO that follows.
Dislocation gliding and cross-hatch morphology formation in AIII-BV epitaxial heterostructures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovalskiy, V. A., E-mail: kovalva@iptm.ru; Vergeles, P. S.; Eremenko, V. G.
2014-12-08
An approach for understanding the origin of cross-hatch pattern (CHP) on the surface of lattice mismatched GaMnAs/InGaAs samples grown on GaAs (001) substrates is developed. It is argued that the motion of threading dislocations in the (111) slip planes during the relaxation of InGaAs buffer layer is more complicated process and its features are similar to the ones of dislocation half-loops gliding in plastically deformed crystals. The heterostructures were characterized by atomic force microscopy and electron beam induced current (EBIC). Detailed EBIC experiments revealed contrast features, which cannot be accounted for by the electrical activity of misfit dislocations at themore » buffer/substrate interface. We attribute these features to specific extended defects (EDs) generated by moving threading dislocations in the partially relaxed InGaAs layers. We believe that the core topology, surface reconstruction, and elastic strains from these EDs accommodated in slip planes play an important role in the CHP formation. The study of such electrically active EDs will allow further understanding of degradation and changes in characteristics of quantum devices based on strained heterostructures.« less
Use of hydrogen etching to remove existing dislocations in GaN epitaxial layers
NASA Astrophysics Data System (ADS)
Yeh, Yen-Hsien; Chu, Chung-Ming; Wu, Yin-Hao; Hsu, Ying-Chia; Yu, Tzu-Yi; Lee, Wei-I.
2015-08-01
In this paper, based on the anisotropic nature of hydrogen (H2) etching on GaN, we describe a new approach to the removal of threading dislocations in GaN layers. The top surfaces of c-plane (Ga-face) and a-plane GaNs are considered stable in H2; therefore, H2 etches only crystal imperfections such as dislocation and basal plane stacking fault (BSF) sites. We used H2 to etch undoped c-plane GaN, n-type c-plane GaN, a-plane GaN, and an InGaN/GaN multiple quantum well structure. Several examinations were performed, indicating deep cavities on the c-plane GaN samples after H2 etching; furthermore, gorge-like grooves were observed on the a-plane GaN samples. The deep cavities on the c-plane GaN were considered the etched dislocation sites, and the gorge-like grooves on the a-plane GaN were considered the etched BSF sites. Photoluminescence measurements were performed and the results indicated that the H2-etched samples demonstrate superior optoelectronic properties, probably because of the elimination of dislocations.
Hydrogen-vacancy-dislocation interactions in α-Fe
NASA Astrophysics Data System (ADS)
Tehranchi, A.; Zhang, X.; Lu, G.; Curtin, W. A.
2017-02-01
Atomistic simulations of the interactions between dislocations, hydrogen atoms, and vacancies are studied to assess the viability of a recently proposed mechanism for the formation of nanoscale voids in Fe-based steels in the presence of hydrogen. Quantum-mechanics/molecular-mechanics method calculations confirm molecular statics simulations based on embedded atom method (EAM) potential showing that individual vacancies on the compressive side of an edge dislocation can be transported with the dislocation as it glides. Molecular dynamics simulations based on EAM potential then show, however, that vacancy clusters in the glide plane of an approaching dislocation are annihilated or reduced in size by the creation of a double-jog/climb process that is driven by the huge reduction in energy accompanying vacancy annihilation. The effectiveness of annihilation/reduction processes is not reduced by the presence of hydrogen in the vacancy clusters because typical V-H cluster binding energies are much lower than the vacancy formation energy, except at very high hydrogen content in the cluster. Analysis of a range of configurations indicates that hydrogen plays no special role in stabilizing nanovoids against jog formation processes that shrink voids. Experimental observations of nanovoids on the fracture surfaces of steels must be due to as-yet undetermined processes.
Kim, Hui Taek; Ahn, Tae Young; Jang, Jae Hoon; Kim, Kang Hee; Lee, Sung Jae; Jung, Duk Young
2017-03-01
Three-dimensional (3D) computed tomography imaging is now being used to generate 3D models for planning orthopaedic surgery, but the process remains time consuming and expensive. For chronic radial head dislocation, we have designed a graphic overlay approach that employs selected 3D computer images and widely available software to simplify the process of osteotomy site selection. We studied 5 patients (2 traumatic and 3 congenital) with unilateral radial head dislocation. These patients were treated with surgery based on traditional radiographs, but they also had full sets of 3D CT imaging done both before and after their surgery: these 3D CT images form the basis for this study. From the 3D CT images, each patient generated 3 sets of 3D-printed bone models: 2 copies of the preoperative condition, and 1 copy of the postoperative condition. One set of the preoperative models was then actually osteotomized and fixed in the manner suggested by our graphic technique. Arcs of rotation of the 3 sets of 3D-printed bone models were then compared. Arcs of rotation of the 3 groups of bone models were significantly different, with the models osteotomized accordingly to our graphic technique having the widest arcs. For chronic radial head dislocation, our graphic overlay approach simplifies the selection of the osteotomy site(s). Three-dimensional-printed bone models suggest that this approach could improve range of motion of the forearm in actual surgical practice. Level IV-therapeutic study.
Wimberley, David W; Vaccaro, Alexander R; Goyal, Nitin; Harrop, James S; Anderson, D Greg; Albert, Todd J; Hilibrand, Alan S
2005-08-01
A case report of acute quadriplegia resulting from closed traction reduction of traumatic bilateral cervical facet dislocation in a 54-year-old male with concomitant ossification of the posterior longitudinal ligament (OPLL). To report an unusual presentation of a spinal cord injury, examine the approach to reversal of the injury, and review the treatment and management controversies of acute cervical facet dislocations in specific patient subgroups. The treatment of acute cervical facet dislocations is an area of ongoing controversy, especially regarding the question of the necessity of advanced imaging studies before closed traction reduction of the dislocated cervical spine. The safety of an immediate closed, traction reduction of the cervical spine in awake, alert, cooperative, and appropriately select patients has been reported in several studies. To date, there have been no permanent neurologic deficits resulting from awake, closed reduction reported in the literature. A case of temporary, acute quadriplegia with complete neurologic recovery following successful closed traction reduction of a bilateral cervical facet dislocation in the setting of OPLL is presented. The clinical neurologic examination, radiographic, and advanced imaging studies before and after closed, traction reduction of a cervical facet dislocation are evaluated and discussed. A review of the literature regarding the treatment of acute cervical facet dislocations is presented. Radiographs showed approximately 50% subluxation of the fifth on the sixth cervical vertebrae, along with computerized tomography revealing extensive discontinuous OPLL. The cervical facet dislocation was successfully reduced with an awake, closed traction reduction, before magnetic resonance imaging (MRI) evaluation. The patient subsequently had acute quadriplegia develop, with the ensuing MRI study illustrating severe spinal stenosis at the C5, C6 level as a result of OPLL or a large extruded disc herniation. Following an immediate anterior decompression and a posterior stabilization procedure, the patient regained full motor and sensory function. This case report highlights the advantages and shows some safety concerns regarding immediate, closed traction reduction of cervical facet dislocation with real-time neural monitoring in an awake, alert, oriented, and appropriately select patient before MRI studies in the setting of preexisting central stenosis from OPLL.
Modeling collective behavior of dislocations in crystalline materials
NASA Astrophysics Data System (ADS)
Varadhan, Satya N.
Elastic interaction of dislocations leads to collective behavior and determines plastic response at the mesoscale. Notable characteristics of mesoscale plasticity include the formation of dislocation patterns, propagative instability phenomena due to strain aging such as the Luders and Portevin-Le Chatelier effects, and size-dependence of low stress. This work presents a unified approach to modeling collective behavior based on mesoscale field dislocation mechanics and crystal plasticity, using constitutive models with physical basis. Successful application is made to: compression of a bicrystal, where "smaller is stronger"---the flow stress increases as the specimen size is reduced; torsional creep of ice single crystals, where the plastic strain rate increases with time under constant applied torque; strain aging in a single crystal alloy, where the transition from homogeneous deformation to intermittent bands to continuous band is captured as the applied deformation rate is increased. A part of this work deals with the kinematics of dislocation density evolution. An explicit Galerkin/least-squares formulation is introduced for the quasilinear evolution equation, which leads to a symmetric and well-conditioned system of equations with constant coefficients, making it attractive for large-scale problems. It is shown that the evolution equation simplifies to the Hamilton-Jacobi equations governing geometric optics and level set methods in the following physical contexts: annihilation of dislocations, expansion of a polygonal dislocation loop and operation of a Frank-Read source. The weak solutions to these equations are not unique, and the numerical method is able to capture solutions corresponding to shock as well as expansion fans.
NASA Astrophysics Data System (ADS)
Trempa, M.; Beier, M.; Reimann, C.; Roßhirth, K.; Friedrich, J.; Löbel, C.; Sylla, L.; Richter, T.
2016-11-01
In this work the dislocation formation in the seed crystal induced by feedstock indentation during the growth of quasimono (QM) silicon ingots for photovoltaic application was investigated. It could be shown by special laboratory indentation experiments that the formed dislocations propagate up to several millimeters deep into the volume of the seed crystal in dependence on the applied pressure of the feedstock particles on the surface of the seed crystal. Further, it was demonstrated that these dislocations if they were not back-melted during the seeding process grow further into the silicon ingot and drastically reduce its material quality. An estimation of the apparent pressure values in a G5 industrial crucible/feedstock setup reveals that the indentation phenomenon is a critical issue for the industrial production of QM silicon ingots. Therefore, some approaches to avoid/reduce the indentation events were tested with the result, that the most promising solution should be the usage of suitable feedstock particles as coverage of the seed.
Conservative management of tendinopathies around hip
Frizziero, Antonio; Vittadini, Filippo; Pignataro, Andrea; Gasparre, Giuseppe; Biz, Carlo; Ruggieri, Pietro; Masiero, Stefano
2016-01-01
Summary Background The anatomy of hip is widely complex and several anatomical structures interact and contribute to its functioning. For position and role, hip and the surrounding tendons, which have their insertion around, are overstressed and often overloaded, especially in athletes. This could lead to the developing of several tendinopathies, among which the differential diagnosis is often complicated. Many conservative treatments are used in clinical practice, while actually, no defined conservative protocol is recommended. Methods This is a review article. The aim of this manuscript is to evaluate the current evidences about the effectiveness of conservative management in hip tendinopathies. Conclusion Conservative treatment is effective in the management of hip tendinopathies and may be considered the first-line approach for patients affected. However, there is lack of evidences about which is the most effective treatment. Exercise therapy seems to provide long-term pain relief, but the literature is still lacking about the correct type, dose, posology, intensity of exercise prescribed. Further studies about different local approaches, as PRP or hyaluronic acid injections, may be encouraged. Level of evidence I. PMID:28066732
McGonagle, L; Siney, P D; Raut, V V
2015-11-01
After primary total hip replacement, aseptic loosening of the acetabular cup is more common than loosening of the femoral stem. Removal of a well-fixed stem adds to operative time, blood loss, risk of bone loss and fracture. There is limited evidence that isolated cup revision can be a safe option in revision hip arthroplasty. We question the following regarding the unrevised cemented stem after isolated cup revision: 1) Does the unrevised stem require revision after isolated cup revision? 2) When is the stem subsequently revised? 3) Why is the stem subsequently revised? 4) Do unrevised stems exhibit radiographic loosening? We hypothesise that after isolated cup revision most unrevised stems do not need subsequent revision, and that most do not exhibit evidence of radiographic loosening. A retrospective analysis of all patients who underwent revision of the acetabular component only during revision hip arthroplasty between March 1970 and July 2013 was carried out. We assessed survival of the unrevised stem, reasons for subsequent revision, plus radiographic analysis for stem loosening. Two hundred and twenty-seven hips were included [215 patients with an average age at the time of primary surgery was 47 (13-70) years]. The Charnley stem was used in 161 cases; C-stem 65, Howse 1. Average time between primary surgery and cup revision was 15.9 (1.6-33.4) years. Average follow-up for all stems post-isolated cup revision was 6.1 (0.1-30.7) years. Twenty-eight stems (12.3%) were subsequently revised 5.1 (0.1-12.6) years after the isolated cup revision. Reasons for subsequent revision were: aseptic loosening (10); infection (8); dislocation (6); unreconstructable joint post-loose cup removal (2); fracture (2). Radiographic review was possible on 140 cases. Five femoral stems were revised and 2 others showed evidence of possible radiological loosening but were not revised. To our knowledge this is the largest series showing that isolated cup revision in the place of a well-fixed cemented stem is safe and is associated with ongoing good long-term survival of the stem. Level IV, retrospective case series. Copyright © 2015. Published by Elsevier Masson SAS.
2013-05-31
j] (11) A MATLAB code was written for finding the displacement at each node for all time steps. Material selected for the study was steel with 1 m...some of the dislocations are annihilated or rearranged. Various stages in the recovery are, entanglement of dislocations, cell formation, annihilation...frequency domain using an in-house pro- gram written in MATLAB . A time-domain signal obtained from nonlinear measurement and its corresponding fast
Kawai, Toshiyuki; Tanaka, Chiaki; Kanoe, Hiroshi
2014-03-10
Several authors reported encouraging results of total hip arthroplasty (THA) for Crowe IV hips performed using shortening osteotomy. However, few papers have documanted the results of THA for Crowe IV hips without shortening osteotomy. The aim of the present study was to assess the long term-results of cemented THAs for Crowe group IV hips performed without subtrochanteric shortening osteotomy. We have assessed the long term results of 27 cemented total hip arthroplasty (THA) performed without subtrochanteric osteotomy for Crowe group IV hip. All THAs were performed via transtrochanteric approach. After a mean follow-up of 10.6 (6 to 17.9) years, 25 hips (92.6%) had survived without revision surgery and survivorship analysis gave a survival rate of 96.3% at 10 years with any revision surgery as the end point. Although mean limb lengthening was 3.2 (1.0 to 5.1) cm, no hips developed nerve palsy. Complications occurred in four hips, necessitating revision surgery in two. Among the four complications, three involved the greater trochanter, two of which occurred in cases where braided cables had been used to reattach the greater trochanter. Although we encountered four complications, including three trochanteric problems, our findings suggest that THA without subtrochanteric shortening osteotomy can provide satisfactory long-term results in patients with Crowe IV hip.
Carrell, David; Malin, Bradley; Aberdeen, John; Bayer, Samuel; Clark, Cheryl; Wellner, Ben; Hirschman, Lynette
2013-01-01
Secondary use of clinical text is impeded by a lack of highly effective, low-cost de-identification methods. Both, manual and automated methods for removing protected health information, are known to leave behind residual identifiers. The authors propose a novel approach for addressing the residual identifier problem based on the theory of Hiding In Plain Sight (HIPS). HIPS relies on obfuscation to conceal residual identifiers. According to this theory, replacing the detected identifiers with realistic but synthetic surrogates should collectively render the few 'leaked' identifiers difficult to distinguish from the synthetic surrogates. The authors conducted a pilot study to test this theory on clinical narrative, de-identified by an automated system. Test corpora included 31 oncology and 50 family practice progress notes read by two trained chart abstractors and an informaticist. Experimental results suggest approximately 90% of residual identifiers can be effectively concealed by the HIPS approach in text containing average and high densities of personal identifying information. This pilot test suggests HIPS is feasible, but requires further evaluation. The results need to be replicated on larger corpora of diverse origin under a range of detection scenarios. Error analyses also suggest areas where surrogate generation techniques can be refined to improve efficacy. If these results generalize to existing high-performing de-identification systems with recall rates of 94-98%, HIPS could increase the effective de-identification rates of these systems to levels above 99% without further advancements in system recall. Additional and more rigorous assessment of the HIPS approach is warranted.
Schneider, Adrian K; Pierrepont, Jim W; Hawdon, Gabrielle; McMahon, Stephen
2018-04-01
Patient specific guides can be a valuable tool in improving the precision of planned femoral neck osteotomies, especially in minimally invasive hip surgery, where bony landmarks are often inaccessible. The aim of our study was to validate the accuracy of a novel patient specific femoral osteotomy guide for THR through a minimally invasive posterior approach, the direct superior approach (DSA). As part of our routine preoperative planning 30 patients underwent low dose CT scans of their arthritic hip. 3D printed patient specific femoral neck osteotomy guides were then produced. Intraoperatively, having cleared all soft tissue from the postero-lateral neck of the enlocated hip, the guide was placed and pinned onto the posterolateral femoral neck. The osteotomy was performed using an oscillating saw and the uncemented hip components were implanted as per routine. Postoperatively, the achieved level of the osteotomy at the medial calcar was compared with the planned level of resection using a 3D/2D matching analysis (Mimics X-ray module, Materialise, Belgium). A total of 30 patients undergoing uncemented Trinity™ acetabular and TriFit TS™ femoral component arthroplasty (Corin, UK) were included in our analysis. All but one of our analysed osteotomies were found to be within 3 mm from the planned height of osteotomy. In one patient the level of osteotomy deviated 5 mm below the planned level of resection. Preoperative planning and the use of patient specific osteotomy guides provides an accurate method of performing femoral neck osteotomies in minimally invasive hip arthroplasty using the direct superior approach. IV (Case series).
NASA Astrophysics Data System (ADS)
Fan, Jinghong; Hao, Su
2004-01-01
Material heterogeneities and discontinuities such as porosity, second phase particles, and other defects at meso/micro/nano scales, determine fatigue life, strength, and fracture behavior of aluminum castings. In order to achieve better performance of these alloys, a design-centered computer-aided renovative approach is proposed. Here, the term “design-centered” is used to distinguish the new approach from the traditional trial-and-error design approach by formulating a clear objective, offering a scientific foundation, and developing a computer-aided effective tool for the alloy development. A criterion for tailoring “child” microstructure, obtained by “parent” microstructure through statistical correlation, is proposed for the fatigue design at the initial stage. A dislocations pileup model has been developed. This dislocation model, combined with an optimization analysis, provides an analytical-based solution on a small scale for silicon particles and dendrite cells to enhance both fatigue performance and strength for pore-controlled castings. It can also be used to further tailor microstructures. In addition, a conceptual damage sensitivity map for fatigue life design is proposed. In this map there are critical pore sizes, above which fatigue life is controlled by pores; otherwise it is controlled by other mechanisms such as silicon particles and dendrite cells. In the latter case, the proposed criteria and the dislocation model are the foundations of a guideline in the design-centered approach to maximize both the fatigue life and strength of Al-Si-based light-weight alloy.
Perioperative Pain Management in Total Hip Arthroplasty: Korean Hip Society Guidelines
Kim, Yeesuk; Cho, Hong-Man; Park, Kyung-Soon; Yoon, Pil Whan; Nho, Jae-Hwi; Kim, Sang-Min; Lee, Kyung-Jae; Moon, Kyong-Ho
2016-01-01
Effective perioperative pain management techniques and accelerated rehabilitation programs can improve health-related quality of life and functional status of patients after total hip arthroplasty. Traditionally, postoperative analgesia following arthroplasty was provided by intravenous patient-controlled analgesia or epidural analgesia. Recently, peripheral nerve blockade has emerged alternative analgesic approach. Multimodal analgesia strategy combines analgesics with different mechanisms of action to improve pain management. Intraoperative periarticular injection of multimodal drugs is one of the most important procedures in perioperative pain control for total hip arthroplasty. The goal of this review article is to provide a concise overview of the principles of multimodal pain management regimens as a practical guide for the perioperative pain management for total hip arthroplasty. PMID:27536639
Searching for solar siblings among the HARPS data
NASA Astrophysics Data System (ADS)
Batista, S. F. A.; Adibekyan, V. Zh.; Sousa, S. G.; Santos, N. C.; Delgado Mena, E.; Hakobyan, A. A.
2014-04-01
The search for solar siblings has been particularly fruitful in the past few years. At present, there are four plausible candidates reported in the literature: HIP21158, HIP87382, HIP47399, and HIP92831. In this study we conduct a search for solar siblings among the HARPS high-resolution FGK dwarfs sample, which includes precise chemical abundances and kinematics for 1111 stars. Using a new approach based on chemical abundance trends with condensation temperature, kinematics, and ages we found one (additional) potential solar sibling candidate: HIP97507. Based on observations collected at the La Silla Paranal Observatory, ESO (Chile) with the HARPS spectrograph at the 3.6-m telescope (ESO runs ID 72.C-0488, 082.C-0212, and 085.C-0063).
Economic viability of geriatric hip fracture centers.
Clement, R Carter; Ahn, Jaimo; Mehta, Samir; Bernstein, Joseph
2013-12-01
Management of geriatric hip fractures in a protocol-driven center can improve outcomes and reduce costs. Nonetheless, this approach has not spread as broadly as the effectiveness data would imply. One possible explanation is that operating such a center is not perceived as financially worthwhile. To assess the economic viability of dedicated hip fracture centers, the authors built a financial model to estimate profit as a function of costs, reimbursement, and patient volume in 3 settings: an average US hip fracture program, a highly efficient center, and an academic hospital without a specific hip fracture program. Results were tested with sensitivity analysis. A local market analysis was conducted to assess the feasibility of supporting profitable hip fracture centers. The results demonstrate that hip fracture treatment only becomes profitable when the annual caseload exceeds approximately 72, assuming costs characteristic of a typical US hip fracture program. The threshold of profitability is 49 cases per year for high-efficiency hip fracture centers and 151 for the urban academic hospital under review. The largest determinant of profit is reimbursement, followed by costs and volume. In the authors’ home market, 168 hospitals offer hip fracture care, yet 85% fall below the 72-case threshold. Hip fracture centers can be highly profitable through low costs and, especially, high revenues. However, most hospitals likely lose money by offering hip fracture care due to inadequate volume. Thus, both large and small facilities would benefit financially from the consolidation of hip fracture care at dedicated hip fracture centers. Typical US cities have adequate volume to support several such centers.
van der Spek, Jaap H; Veltink, Peter H; Hermens, Hermie J; Koopman, Bart F J M; Boom, Herman B K
2003-12-01
The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hip-joint stiffness for changing crutch placement and hip-joint offset angle was studied under static and dynamic conditions. Modeling results indicate that, by using additional hip-joint stiffness, stable crutch supported paraplegic standing can be achieved, both under static as well as dynamic situations. The static equilibrium postures and the stability under perturbations were calculated to be dependent on crutch placement and stiffness applied. However, postures in which the hip joint was in extension (C postures) appeared to the most stable postures. Applying at least 60 N x m/rad hip-joint stiffness gave stable equilibrium postures in all cases. Choosing appropriate hip-joint offset angles, the static equilibrium postures changed to more erect postures, without causing instability or excessive arm forces to occur.
Yilmaz, Serdar; Aksahin, Ertugrul; Ersoz, Murat; Bicimoglu, Ali
2017-09-01
The impact on long-term weakness of hip flexion of complete iliopsoas tenotomy during open reduction of developmental hip dysplasia with a medial approach has not yet been fully clarified. The purpose of this study was to investigate the isokinetic muscle strength (IMS) of hip flexor and extensor muscles in these patients and also to analyze the effect of spontaneous reattachment of the iliopsoas muscle on IMS measurements. The study included 20 patients. Earlier magnetic resonance imaging examination of all the patients revealed spontaneous reattachment of the iliopsoas in 18 (90%) patients. IMS measurements were performed at 60 and 150 degrees/s. The peak torque, total work (TW), average power (AP), work fatigue, and agonist to antagonist muscle ratio of the operated and nonoperated hips were recorded separately for flexors and extensors. The effect of iliopsoas reattachment on IMS was also evaluated. The mean follow-up period was 16.65±2.16 (13 to 20) years. Total work (P=0.013) and average power (P=0.009) of the flexor muscles and work fatigue of the extensor muscles (P=0.030) of the operated hip were significantly decreased when compared with the nonoperated hips at 150 degrees/s. There was no significant difference between the flexor muscles of the operated and nonoperated hips (P<0.05) at 60 degrees/s and extensor muscles (P<0.05) at 150 degrees/s. In addition, patients without reattachment had lower IMS in the operated hips. Flexor muscle strength was decreased in the operated hip against low resistance in long-term follow-up after iliopsoas tenotomy. This may reflect that hip muscle strength was decreased after prolonged activities such as sports. However, in forceful activities flexor muscle strength was retained due to iliopsoas reattachment. On the basis of this study we thought that spontaneous reattachment of the iliopsoas tendon substantially preserves muscle strength. Nonetheless possible efforts should be made to surgically reattach the psoas tendon to preserve strength of the muscle. Therapeutic level IV.
NASA Astrophysics Data System (ADS)
Ramazani, Ali; Mukherjee, Krishnendu; Prahl, Ulrich; Bleck, Wolfgang
2012-10-01
The flow behavior of dual-phase (DP) steels is modeled on the finite-element method (FEM) framework on the microscale, considering the effect of the microstructure through the representative volume element (RVE) approach. Two-dimensional RVEs were created from microstructures of experimentally obtained DP steels with various ferrite grain sizes. The flow behavior of single phases was modeled through the dislocation-based work-hardening approach. The volume change during austenite-to-martensite transformation was modeled, and the resultant prestrained areas in the ferrite were considered to be the storage place of transformation-induced, geometrically necessary dislocations (GNDs). The flow curves of DP steels with varying ferrite grain sizes, but constant martensite fractions, were obtained from the literature. The flow curves of simulations that take into account the GND are in better agreement with those of experimental flow curves compared with those of predictions without consideration of the GND. The experimental results obeyed the Hall-Petch relationship between yield stress and flow stress and the simulations predicted this as well.
Han, Xiaodong; Wang, Lihua; Yue, Yonghai; Zhang, Ze
2015-04-01
In this review, we briefly introduce our in situ atomic-scale mechanical experimental technique (ASMET) for transmission electron microscopy (TEM), which can observe the atomic-scale deformation dynamics of materials. This in situ mechanical testing technique allows the deformation of TEM samples through a simultaneous double-tilt function, making atomic-scale mechanical microscopy feasible. This methodology is generally applicable to thin films, nanowires (NWs), tubes and regular TEM samples to allow investigation of the dynamics of mechanically stressed samples at the atomic scale. We show several examples of this technique applied to Pt and Cu single/polycrystalline specimens. The in situ atomic-scale observation revealed that when the feature size of these materials approaches the nano-scale, they often exhibit "unusual" deformation behaviours compared to their bulk counterparts. For example, in Cu single-crystalline NWs, the elastic-plastic transition is size-dependent. An ultra-large elastic strain of 7.2%, which approaches the theoretical elasticity limit, can be achieved as the diameter of the NWs decreases to ∼6 nm. The crossover plasticity transition from full dislocations to partial dislocations and twins was also discovered as the diameter of the single-crystalline Cu NWs decreased. For Pt nanocrystals (NC), the long-standing uncertainties of atomic-scale plastic deformation mechanisms in NC materials (grain size G less than 15 nm) were clarified. For larger grains with G<∼10 nm, we frequently observed movements and interactions of cross-grain full dislocations. For G between 6 and 10 nm, stacking faults resulting from partial dislocations become more frequent. For G<∼6 nm, the plasticity mechanism transforms from a mode of cross-grain dislocation to a collective grain rotation mechanism. This grain rotation process is mediated by grain boundary (GB) dislocations with the assistance of GB diffusion and shuffling. These in situ atomic-scale images provide a direct demonstration that grain rotation, through the evolution of the misorientation angle between neighbouring grains, can be quantitatively assessed by the dislocation content within the grain boundaries. In combination with the revolutionary Cs-corrected sub-angstrom imaging technologies developed by Urban et al., the opportunities for experimental mechanics at the atomic scale are emerging. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Modelling irradiation-induced softening in BCC iron by crystal plasticity approach
NASA Astrophysics Data System (ADS)
Xiao, Xiazi; Terentyev, Dmitry; Yu, Long; Song, Dingkun; Bakaev, A.; Duan, Huiling
2015-11-01
Crystal plasticity model (CPM) for BCC iron to account for radiation-induced strain softening is proposed. CPM is based on the plastically-driven and thermally-activated removal of dislocation loops. Atomistic simulations are applied to parameterize dislocation-defect interactions. Combining experimental microstructures, defect-hardening/absorption rules from atomistic simulations, and CPM fitted to properties of non-irradiated iron, the model achieves a good agreement with experimental data regarding radiation-induced strain softening and flow stress increase under neutron irradiation.
Total hip replacement for hip fracture: Surgical techniques and concepts.
Coomber, Ross; Porteous, Matthew; Hubble, Matthew J W; Parker, Martyn J
2016-10-01
When treating a hip fracture with a total hip replacement (THR) the surgical technique may differ in a number of aspects in comparison to elective arthroplasty. The hip fracture patient is more likely to have poor bone stock secondary to osteoporosis, be older, have a greater number of co-morbidities, and have had limited peri-operative work-up. These factors lead to a higher risk of complications, morbidity and perioperative mortality. Consideration should be made to performing the THR in a laminar flow theatre, by a surgeon experienced in total hip arthroplasty, using an anterolateral approach, cementing the implant in place, using a large head size and with repair of the joint capsule. Combined Ortho-geriatric care is recommended with similar post-operative rehabilitation to elective THR patients but with less expectation of short length of stay and consideration for fracture prevention measures. Copyright © 2016. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Yang, Zailin; Yang, Qinyou; Zhang, Guowei; Yang, Yong
2018-03-01
The relationship between void size/location and mechanical behavior under biaxial loading of copper nanosheets containing voids are investigated by molecular dynamics method. The void location and the void radius on the model are discussed in the paper. The main reason of break is discovered by the congruent relationship between the shear stress and its dislocations. Dislocations are nucleated at the corner of system and approached to the center of void with increased deformation. Here, a higher stress is required to fail the voided sheets when smaller voids are utilized. The void radius influences the time of destruction. The larger the void radius is, the lower the shear stress and the earlier the model breaks. The void location impacts the dislocation distribution.
Rare Complication in Third Maxillary Molar Extraction: Dislocation in Infratemporal Fossa.
Battisti, Andrea; Priore, Paolo; Giovannetti, Filippo; Barbera, Giorgio; D'Alessandro, Francesco; Valentini, Valentino
2017-10-01
Removal of impacted third maxillary molar is frequently carried out without difficulties and low rate of intraoperative complications. The rare and particularly challenger to manage it is the third molar dislocation into the infratemporal fossa (IF). In this clinical report, the authors present their solution to manage and resolve this particular complication. A 28-year-old woman was referred to the emergency rescue unit of the authors' hospital by her dentistry, after the attempt to extract the left impacted maxillary third molar. During the procedure the tooth accidentally dislodged and was lost sight of it. The patient had significant mouth-opening limitation, omolateral mid face swelling and pain. Computer tomography was immediately performed to determine the exact position of the tooth, showing the dental element dislocated into the IF. Considering all of possible complications the best surgical option must guarantee a direct approach and a constant eye contact of the tooth, even in case of further displacement during the procedure, and allow early surgery. The authors used an endoscopic transoral approach through the preexisted access and solved all the issues reducing morbidity. Removing tooth from the IF could be burdened by serious risk of bleeding and/or nerve injury. The endoscopic approach provides direct view of the IF reducing morbidity.
Weninger, Patrick; Tschabitscher, Manfred; Traxler, Hannes; Pfafl, Veronika; Hertz, Harald
2010-04-01
Although a lateral starting point for tibial nailing is recommended to avoid valgus misalignment, higher rates of intra-articular damage were described compared with a medial parapatellar approach. The aim of this anatomic study was to evaluate the fracture level allowing for a safe medial nail entry point without misalignment or dislocation of fragments. Thirty-two fresh-frozen cadaver lower extremities were used to create 1-cm osteotomies at four different levels (n = 8) from 2 cm to 8 cm below the tibial tuberosity. Nine-millimeter unreamed solid titanium tibial nails (Connex, I.T.S. Spectromed, Lassnitzhohe, Austria) were inserted from a medial parapatellar incision. Misalignment (degree) and dislocation of the distal fragment were measured in the frontal and sagittal plane. A medial parapatellar approach for tibial nail insertion mainly caused valgus and anterior bow misalignment and ventral and medial fragment displacement. Mean misalignment and fragment displacement did not exceed 0.5 degree if the osteotomy was performed 8 cm to 9 cm below the tibial tuberosity. According to the results of this study, a medial parapatellar approach can be performed without misalignment and fragment dislocation in proximal tibia fractures extending 8 cm or more below the tibial tuberosity.
Mechanisms for Ductile Rupture - FY16 ESC Progress Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyce, Brad L.; Carroll, Jay D.; Noell, Phillip
2017-01-01
Ductile rupture in metals is generally a multi-step process of void nucleation, growth, and coalescence. Particle decohesion and particle fracture are generally invoked as the primary microstructural mechanisms for room-temperature void nucleation. However, because high-purity materials also fail by void nucleation and coalescence, other microstructural features must also act as sites for void nucleation. Early studies of void initiation in high-purity materials, which included post-mortem fracture surface characterization using scanning electron microscopy (SEM) and high-voltage electron microscopy (HVEM) and in-situ HVEM observations of fracture, established the presence of dislocation cell walls as void initiation sites in high-purity materials. Direct experimentalmore » evidence for this contention was obtained during in-situ HVEM tensile tests of Be single crystals. Voids between 0.2 and 1 μm long appeared suddenly along dislocation cell walls during tensile straining. However, subsequent attempts to replicate these results in other materials, particularly α -Fe single crystals, were unsuccessful because of the small size of the dislocation cells, and these remain the only published in-situ HVEM observations of void nucleation at dislocation cell walls in the absence of a growing macrocrack. Despite this challenge, other approaches to studying void nucleation in high-purity metals also indicate that dislocation cell walls are nucleation sites for voids.« less
NASA Astrophysics Data System (ADS)
Wallis, David; Lloyd, Geoffrey E.; Hansen, Lars N.
2018-02-01
The onset of frictional failure and potentially seismogenic deformation in carbonate rocks undergoing exhumation within fault zones depends on hardening processes that reduce the efficiency of aseismic dislocation-mediated deformation as temperature decreases. However, few techniques are available for quantitative analysis of dislocation slip system activity and hardening in natural tectonites. Electron backscatter diffraction maps of crystal orientations offer one such approach via determination of Schmid factors, if the palaeostress conditions can be inferred and the critical resolved shear stresses of slip systems are constrained. We analyse calcite marbles deformed in simple shear within the Karakoram Fault Zone, NW India, to quantify changes in slip system activity as the rocks cooled during exhumation. Microstructural evidence demonstrates that between ∼300 °C and 200-250 °C the dominant deformation mechanisms transitioned from dislocation-mediated flow to twinning and frictional failure. However, Schmid factor analysis, considering critical resolved shear stresses for yield of undeformed single crystals, indicates that the fraction of grains with sufficient resolved shear stress for glide apparently increased with decreasing temperature. Misorientation analysis and previous experimental data indicate that strain-dependent work hardening is responsible for this apparent inconsistency and promoted the transition from dislocation-mediated flow to frictional, and potentially seismogenic, deformation.
Discrete dislocation plasticity analysis of loading rate-dependent static friction.
Song, H; Deshpande, V S; Van der Giessen, E
2016-08-01
From a microscopic point of view, the frictional force associated with the relative sliding of rough surfaces originates from deformation of the material in contact, by adhesion in the contact interface or both. We know that plastic deformation at the size scale of micrometres is not only dependent on the size of the contact, but also on the rate of deformation. Moreover, depending on its physical origin, adhesion can also be size and rate dependent, albeit different from plasticity. We present a two-dimensional model that incorporates both discrete dislocation plasticity inside a face-centred cubic crystal and adhesion in the interface to understand the rate dependence of friction caused by micrometre-size asperities. The friction strength is the outcome of the competition between adhesion and discrete dislocation plasticity. As a function of contact size, the friction strength contains two plateaus: at small contact length [Formula: see text], the onset of sliding is fully controlled by adhesion while for large contact length [Formula: see text], the friction strength approaches the size-independent plastic shear yield strength. The transition regime at intermediate contact size is a result of partial de-cohesion and size-dependent dislocation plasticity, and is determined by dislocation properties, interfacial properties as well as by the loading rate.
Dal Molin, Danilo Canesin; Ribeiro, Fabiano Rebouças; Filho, Rômulo Brasil; Filardi, Cantídio Salvador; Tenor, Antonio Carlos; Stipp, Willian Nandi; Petros, Rodrigo Souto Borges
2012-01-01
To evaluate the results from surgical treatment of 84 cases of acute acromioclavicular dislocation, using a posterosuperior access route. Eighty-four cases of acute acromioclavicular dislocation (grade III in the Allman-Tossy classification) operated between November 2002 and May 2010 were evaluated. The patients' mean age was 34 years. The diagnoses were made using clinical and radiographic evaluations. The patients were operated by the same surgical team, within three weeks of the date of the trauma, using a posterosuperior approach to the shoulder to access the top of the base of the coracoid process for placement of two anchors, which were used in reducing the dislocation. The minimum follow-up was 12 months. The postoperative clinical-radiographic evaluation was done using the modified Karlsson criteria and the University of California at Los Angeles (UCLA) score. 92.8% of the 84 patients treated presented good or excellent results, and 7.2% presented fair or poor results, using the UCLA assessment score. According to the modified Karlsson criteria, 76.2% were assessed as grade A, 17.9% as grade B and 5.9% as grade C. The posterosuperior access route to the shoulder is a new option for accessing the coracoid process and treating acromioclavicular dislocation, with clinical and radiographic results equivalent to those in the literature.
Cooper, George A; Southorn, Thomas; Eastwood, Deborah M; Bache, C Edward
2016-06-01
Morquio-Brailsford syndrome or mucopolysaccharidosis type IV-A (MPS IV-A) is an inherited metabolic disease in which skeletal deformities can be extreme. An international registry has shown that 46% of patients are unable to walk 200 m and 30% use a wheelchair. Lower limb surgery is performed to restore alignment with the expectation of maintaining mobility. We are, however, not aware of reports correlating function with alignment. This study assesses the role of orthopaedic intervention with reference to anatomic and functional outcome in MPS IV-A: specifically hemiepiphysiodesis correction of genu valgum. Interrogation of the MPS patient database identified 63 patients. Patient demographic and radiographic data were collected along with information on deformity, correction, mobility, and genotype. Genu valgum was assessed by intermalleolar distance and mobility by a standardized 6-minute walk test. Sequential hip anatomy was assessed radiographically. Twenty-six surgical hemiepiphysiodesis episodes were performed on 23 patients. There were no cases of implant failure, loosening, or infection. The average intermalleolar distance reduction was 6.12 cm (paired t test, P=0.0001) (95% confidence interval, 7.6-4.7 cm) and the mean change in 6-minute walk test was +69.5 m (P=0.0339). There was no correlation between hip subluxation/dislocation and mobility (Fisher exact test, P=1.000), although hip parameters deteriorated over time. Three patients required repeat 8-plate insertion and 1 a femoral osteotomy. Eight-plate hemiepiphysiodesis correction of genu valgum in MPS IV-A is an effective treatment with low complication rates. The insult of surgery is minimal compared with that of osteotomy which can reduce mobility further. Our outcomes suggest that mobility is maintained or improved even in severe genotypes where mobility typically worsens. We have found hip pathology to be less debilitating, but further studies are needed to assess the effect of genu valgum correction upon femoral head subluxation and collapse.We suggest hemiepiphysiodesis should be considered as part of the treatment strategy for limb alignment in MPS IV-A patients, depending on remaining growth, mobility status, and genotype. Level IV-therapeutic case series.
Yilmaz, Serdar; Aksahin, Ertugrul; Duran, Semra; Bicimoglu, Ali
2017-09-01
There has been little information about the long-term status of the iliopsoas, which is the main flexor of the hip, after iliopsoas tenotomy in the treatment of developmental dysplasia of the hip (DDH). The aim of this study was to assess the status of the iliopsoas muscle and other flexors and extensors of the hip in long-term follow-up with magnetic resonance imaging after complete iliopsoas tenotomy in patients with unilateral DDH treated with open reduction with a medial approach. The study included 20 patients who underwent open reduction with a medial approach for unilateral DDH and had long-term follow-up. Magnetic resonance imaging assessment of iliopsoas, rectus femoris, tensor fasia lata, sartorius, and gluteus maximus muscles was applied and the muscles of the hip that was operated on were compared with the unoperated hip. In addition, the iliopsoas muscle was examined for reattachment and the effect of reattachment was evaluated. The mean age at the time of operation was 10.53±3.61 months (range, 5 to 18 mo), and mean follow-up was 16.65±2.16 years (range, 13 to 20 y). Spontaneous reattachment of the iliopsoas was observed in 18 patients (90%), either in the lesser trochanter (65%) or the superior part of it (25%). There was no significant difference between the hips that were operated on and those that were not with regard to the mean cross-sectional areas (CSA) of the tensor fascia lata, rectus femoris, sartorius, and gluteus maximus muscles. The CSA of the tensor fascia lata, rectus femoris, sartorius, and gluteus maximus muscles showed no significant difference (P>0.05); however, CSA of iliopsoas muscle was significantly reduced in the operated hip (P<0.001). Although the iliopsoas tendon was atrophied after complete iliopsoas tenotomy, it was reattached in 90% of the patients spontaneously in long-term follow-up. There was no statistically significant compensatory hypertrophy in any muscles in response to iliopsoas atrophy. Level IV-Therapeutic.
Somasundaram, K; Huber, C P; Babu, V; Zadeh, H
2013-04-01
The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve injury. Four patients had a longer recovery period due to stiffness, associated wrist fracture and elbow dislocation. The CaSO4 bone substitute was replaced by normal appearing trabecular bone texture at an average of 6 months in all patients. In our experience, we have found the use of locking plates, calcium sulphate bone substitute and tuberosity repair with high-strength sutures to be a safe and reliable method of internal fixation for complex proximal humeral fractures and fracture-dislocations. Furthermore, we have also found the use of the extended deltoid-splitting approach to be safe and to provide excellent exposure facilitating accurate reduction for fixation of the fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Copyright © 2012 Elsevier Ltd. All rights reserved.
Volpin, A; Konan, S; Biz, C; Tansey, R J; Haddad, F S
2018-04-13
Acetabular revision especially in the presence of severe bone loss is challenging. There is a paucity of literature critiquing contemporary techniques of revision acetabular reconstruction and their outcomes. The purpose of this study was to systematically review the literature and to report clinical outcomes and survival of contemporary acetabular revision arthroplasty techniques (tantalum metal shells, uncemented revision jumbo shells, reinforced cages and rings, oblong shells and custom-made triflange constructs). Full-text papers and those with an abstract in English published from January 2001 to January 2016 were identified through international databases. A total of 50 papers of level IV scientific evidence, comprising 2811 hips in total, fulfilled the inclusion criteria and were included. Overall, patients had improved outcomes irrespective of the technique of reconstruction as documented by postoperative hip scores. Our pooled analysis suggests that oblong cups components had a lower failure rate compared with other different materials considered in this review. Custom-made triflange cups had one of highest failure rates. However, this may reflect the complexity of revisions and severity of bone loss. The most common postoperative complication reported in all groups was dislocation. This review confirms successful acetabular reconstructions using diverse techniques depending on the type of bone loss and highlights key features and outcomes of different techniques. In particular, oblong cups and tantalum shells have successful survivorship.
Spanyer, Jonathon M; Beaumont, Christopher M; Yerasimides, Jonathan G
2017-02-01
Anterior column deficiency of the pelvis may pose a serious threat to the stability of the acetabular component after total hip arthroplasty and, thus, jeopardize the overall success of the procedure. After Institutional Review Board approval, a retrospective review was undertaken to identify all patients undergoing revision total hip arthroplasty with anterior column augmentation through an extended direct anterior approach. Demographics and surgical details were collected, and subjects were followed for a 2-year minimum period to measure patient outcomes and to evaluate for the stability of construct fixation. A novel surgical procedure description was provided and supplemented with an illustrative case example. At 2 years post augmentation, patients had favorable functional outcomes with radiologic evidence of stable fixation. Proximal extension of the direct anterior approach to the hip can facilitate anterior column access and augmentation to improve stability of the hip reconstruction. This treatment may be an alternative to spanning constructs such as cup-cage constructs and custom implants, affording the potential for long-term biologic fixation. Further investigation into this technique is warranted. Copyright © 2016 Elsevier Inc. All rights reserved.
Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis
Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko
2016-01-01
A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668