Inai, Takuma; Takabayashi, Tomoya; Edama, Mutsuaki; Kubo, Masayoshi
2018-04-27
The association between repetitive hip moment impulse and the progression of hip osteoarthritis is a recently recognized area of study. A sit-to-stand movement is essential for daily life and requires hip extension moment. Although a change in the sit-to-stand movement time may influence the hip moment impulse in the sagittal plane, this effect has not been examined. The purpose of this study was to clarify the relationship between sit-to-stand movement time and hip moment impulse in the sagittal plane. Twenty subjects performed the sit-to-stand movement at a self-selected natural speed. The hip, knee, and ankle joint angles obtained from experimental trials were used to perform two computer simulations. In the first simulation, the actual sit-to-stand movement time obtained from the experiment was entered. In the second simulation, sit-to-stand movement times ranging from 0.5 to 4.0 s at intervals of 0.25 s were entered. Hip joint moments and hip moment impulses in the sagittal plane during sit-to-stand movements were calculated for both computer simulations. The reliability of the simulation model was confirmed, as indicated by the similarities in the hip joint moment waveforms (r = 0.99) and the hip moment impulses in the sagittal plane between the first computer simulation and the experiment. In the second computer simulation, the hip moment impulse in the sagittal plane decreased with a decrease in the sit-to-stand movement time, although the peak hip extension moment increased with a decrease in the movement time. These findings clarify the association between the sit-to-stand movement time and hip moment impulse in the sagittal plane and may contribute to the prevention of the progression of hip osteoarthritis.
An in vitro simulation method for the tribological assessment of complete natural hip joints
Fisher, John; Williams, Sophie
2017-01-01
The use of hip joint simulators to evaluate the tribological performance of total hip replacements is widely reported in the literature, however, in vitro simulation studies investigating the tribology of the natural hip joint are limited with heterogeneous methodologies reported. An in vitro simulation system for the complete natural hip joint, enabling the acetabulum and femoral head to be positioned with different orientations whilst maintaining the correct joint centre of rotation, was successfully developed for this study. The efficacy of the simulation system was assessed by testing complete, matched natural porcine hip joints and porcine hip hemiarthroplasty joints in a pendulum friction simulator. The results showed evidence of biphasic lubrication, with a non-linear increase in friction being observed in both groups. Lower overall mean friction factor values in the complete natural joint group that increased at a lower rate over time, suggest that the exudation of fluid and transition to solid phase lubrication occurred more slowly in the complete natural hip joint compared to the hip hemiarthroplasty joint. It is envisaged that this methodology will be used to investigate morphological risk factors for developing hip osteoarthritis, as well as the effectiveness of early interventional treatments for degenerative hip disease. PMID:28886084
Li, Chaoqun; Wang, Yaru; Wang, Yan; Chen, Guangju
2013-11-01
We carried out molecular dynamics simulations and free energy calculations for a series of ternary and diplex models for the HipA protein, HipB dimer, and DNA molecule to address the mechanism of HipA sequestration and the binding order of events from apo HipB/HipA to 2HipA + HipB dimer + DNA complex. The results revealed that the combination of DNA with the HipB dimer is energetically favorable for the combination of HipB dimer with HipA protein. The binding of DNA to HipB dimer induces a long-range allosteric communication from the HipB2 -DNA interface to the HipA-HipB2 interface, which involves the closeness of α1 helices of HipB dimer to HipA protein and formations of extra hydrogen bonds in the HipA-HipB2 interface through the extension of α2/3 helices in the HipB dimer. These simulated results suggested that the DNA molecule, as a regulative media, modulates the HipB dimer conformation, consequently increasing the interactions of HipB dimer with the HipA proteins, which explains the mechanism of HipA sequestration reported by the previous experiment. Simultaneously, these simulations also explored that the thermodynamic binding order in a simulated physiological environment, that is, the HipB dimer first bind to DNA to form HipB dimer + DNA complex, then capturing strongly the HipA proteins to form a ternary complex, 2HipA + HipB dimer + DNA, for sequestrating HipA in the nucleoid. Copyright © 2013 John Wiley & Sons, Ltd.
Ali, Murat; Al-Hajjar, Mazen; Partridge, Susan; Williams, Sophie; Fisher, John; Jennings, Louise M
2016-01-01
Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an electromechanical simulator and pneumatic simulator were used to compare the wear and creep of metal-on-polyethylene components under the same standard gait conditions. In the second part of the study, the same electromechanical hip joint simulator was used to investigate the influence of kinematics on wear. Higher wear rates and penetration depths were observed from the electromechanical simulator compared with the pneumatic simulator. When adduction/abduction was introduced to the gait cycle, there was no significant difference in wear with that obtained under the gait cycle condition without adduction/abduction. This study confirmed the influence of hip simulator design and loading conditions on the wear of polyethylene, and therefore direct comparisons of absolute wear rates between different hip joint simulators should be avoided. This study also confirmed that the resulting wear path was the governing factor in obtaining clinically relevant wear rates, and this can be achieved with either two axes or three axes of rotations. However, three axes of rotation (with the inclusion of adduction/abduction) more closely replicate clinical conditions and should therefore be the design approach for newly developed hip joint simulators used for preclinical testing. PMID:27160559
Ali, Murat; Al-Hajjar, Mazen; Partridge, Susan; Williams, Sophie; Fisher, John; Jennings, Louise M
2016-05-01
Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an electromechanical simulator and pneumatic simulator were used to compare the wear and creep of metal-on-polyethylene components under the same standard gait conditions. In the second part of the study, the same electromechanical hip joint simulator was used to investigate the influence of kinematics on wear. Higher wear rates and penetration depths were observed from the electromechanical simulator compared with the pneumatic simulator. When adduction/abduction was introduced to the gait cycle, there was no significant difference in wear with that obtained under the gait cycle condition without adduction/abduction. This study confirmed the influence of hip simulator design and loading conditions on the wear of polyethylene, and therefore direct comparisons of absolute wear rates between different hip joint simulators should be avoided. This study also confirmed that the resulting wear path was the governing factor in obtaining clinically relevant wear rates, and this can be achieved with either two axes or three axes of rotations. However, three axes of rotation (with the inclusion of adduction/abduction) more closely replicate clinical conditions and should therefore be the design approach for newly developed hip joint simulators used for preclinical testing. © IMechE 2016.
Ramamurti, B S; Estok, D M; Jasty, M; Harris, W H
1998-05-01
We developed an analytical technique to determine the paths traced by specific points on the femoral head against the acetabulum in the human hip joint during gait. The purpose of the study was to apply this technique to the mechanical hip simulators chosen to conduct wear tests on polymeric acetabular liners used in total hip replacements. These simulators differ from one another in the type of motion produced, apart from other variables such as type of lubricant and head position. Due to the variation in the kinematics between the machines, the paths traced by the points on the femoral head against the acetabular liner ranged from simple linear traces to figure-8 loops and quasi-elliptical paths during a single simulator cycle. The distances traveled by these points during the same period also varied appreciably among the different hip simulator designs. These results are important when combined with other studies that have shown that kinematics can play an important role in the outcome of in vitro wear experiments. The kinematic differences quantified in this study can partially explain the substantial differences in wear data reported from different simulator designs and also underscore the usefulness of the technique described in this study in judging the results from different hip simulator experiments.
Finite element analysis of 2-Station hip himulator
NASA Astrophysics Data System (ADS)
Fazli, M. I. M.; Yahya, A.; Shahrom, A.; Nawawi, S. W.; Zainudin, M. R.; Nazarudin, M. S.
2017-10-01
This paper presented the analysis of materials and design architecture of 2-station hip simulator. Hip simulator is a machine used to conduct the joint and wear test of hip prosthetic. In earlier work, the hip simulator was modified and some improvement were made by using SolidWorks software. The simulator consists of 3DOF which controlled by separate stepper motor and a static load that set up by manual method in each station. In this work, finite element analysis (FEA) of hip simulator was implemented to analyse the structure of the design and selected materials used for simulator component. The analysis is completed based on two categories which are safety factor and stress tests. Both design drawing and FEA was done using SolidWorks software. The study of the two categories is performed by applying the peak load up to 4000N on the main frame that is embedded with metal-on-metal hip prosthesis. From FEA, the value of safety factor and degree of stress formation are successfully obtained. All the components exceed the value of 2 for safety factor analysis while the degree of stress formation shows higher value compare to the yield strength of the material. With this results, it provides information regarding part of simulator which are susceptible to destruct. Besides, the results could be used for design improvement and certify the stability of the hip simulator in real application.
A review of virtual reality based training simulators for orthopaedic surgery.
Vaughan, Neil; Dubey, Venketesh N; Wainwright, Thomas W; Middleton, Robert G
2016-02-01
This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In total 11 hip replacements pre-operative planning tools were analysed, plus 9 hip trauma fracture training simulators. Additionally 9 knee arthroscopy simulators and 8 other orthopaedic simulators were included for comparison. The findings are that for orthopaedic surgery simulators in general, there is increasing use of patient-specific virtual models which reduce the learning curve. Modelling is also being used for patient-specific implant design and manufacture. Simulators are being increasingly validated for assessment as well as training. There are very few training simulators available for hip replacement, yet more advanced virtual reality is being used for other procedures such as hip trauma and drilling. Training simulators for hip replacement and orthopaedic surgery in general lag behind other surgical procedures for which virtual reality has become more common. Further developments are required to bring hip replacement training simulation up to date with other procedures. This suggests there is a gap in the market for a new high fidelity hip replacement and resurfacing training simulator. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Yan, Yu; Dowson, Duncan; Neville, Anne
2013-02-01
The second generation Metal-on-Metal (MoM) hip replacements have been considered as an alternative to commonly used Polyethylene-on-Metal (PoM) joint prostheses due to polyethylene wear debris induced osteolysis. However, the role of corrosion and the biofilm formed under tribological contact are still not fully understood. Enhanced metal ion concentrations have been reported widely from hair, blood and urine samples of patients who received metal hip replacements and in isolated cases when abnormally high levels have caused adverse local tissue reactions. An understanding of the origin of metal ions is really important in order to design alloys for reduced ion release. Reciprocating pin-on-plate wear tester is a standard instrument to assess the interaction of corrosion and wear. However, more realistic hip simulator can provide a better understanding of tribocorrosion process for hip implants. It is very important to instrument the conventional hip simulator to enable electrochemical measurements. In this study, simple reciprocating pin-on-plate wear tests and hip simulator tests were compared. It was found that metal ions originated from two sources: (a) a depassivation of the contacting surfaces due to tribology (rubbing) and (b) corrosion of nano-sized wear particles generated from the contacting surfaces. Copyright © 2012 Elsevier Ltd. All rights reserved.
Estimation of wear in total hip replacement using a ten station hip simulator.
Brummitt, K; Hardaker, C S
1996-01-01
The results of hip simulator tests on a total of 16 total hip joints, all of them 22.25 mm Charnley designs, are presented. Wear at up to 6.75 million cycles was assessed by using a coordinate measuring machine. The results gave good agreement with clinical estimates of wear rate on the same design of joint replacement from a number of sources. Good agreement was also obtained when comparison was made with the published results from more sophisticated simulators. The major source of variation in the results was found to occur in the first million cycles where creep predominates. The results of this study support the use of this type of simplified simulator for estimating wear in a total hip prosthesis. The capability to test a significant number of joints simultaneously may make this mechanism preferable to more complex machines in many cases.
NASA Technical Reports Server (NTRS)
Swikert, M. A.; Johnson, R. L.
1976-01-01
Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.
NASA Astrophysics Data System (ADS)
Bertoluzza, A.; Fagnano, C.; Rossi, M.; Tinti, A.; Cacciari, G. L.
2000-03-01
In this work Raman microspectrometry was used to evaluate the crystallinity changes of hip cups made of ultra-high molecular weight polyethylene (UHMWPE). In vitro experiments were carried out using hip joint movement-wear simulators, run for five million cycles in water or bovine calf serum. The hip cups were subjected to mechanical friction with ceramic femoral heads (alumina-zirconia blend). The crystallinity of the polymer hip cups was studied as a function of inner surface position and thickness, from the stressed surface to the unstressed outer one. The Partial Least Square (PLS-l) calibration was used to correlate the Raman spectra with the crystallinity of the polymer measured with DSC calorimetry.
Design of biped hip simulator using SolidWorks
NASA Astrophysics Data System (ADS)
Zainudin, M. R.; Yahya, A.; Fazli, M. I. M.; Syahrom, A.; Harun, F. K. C.; Nazarudin, M. S.
2017-10-01
The increasing number of people who underwent both hip implant surgery based on World Health Organization (WHO) has received massive attention from researchers lately to develop various types of hip simulators in order to test the hip implant. Various number of hip simulator have been developed with different functions and capabilities. This paper presents the design development of biped hip simulator using SolidWorks software by taking into consideration some improvement and modifications. The finite element method is used to test the design whether it is safe to be used or not. The biped hip simulator has been successfully designed and ready to be fabricated as the endurance testing shown a positive results. The von Mises stress induced in the material is an alloy steel which is 2,975,862.3 N/m2 lower than the yield strength. Thus, the design is safe to be used as it obey the safety criterion.
A Hybrid Reality Radiation-free Simulator for Teaching Wire Navigation Skills
Kho, Jenniefer Y.; Johns, Brian D.; Thomas, Geb. W.; Karam, Matthew D.; Marsh, J. Lawrence; Anderson, Donald D.
2016-01-01
Objectives Surgical simulation is an increasingly important method to facilitate the acquiring of surgical skills. Simulation can be helpful in developing hip fracture fixation skills because it is a common procedure for which performance can be objectively assessed (i.e., the tip-apex distance). The procedure requires fluoroscopic guidance to drill a wire along an osseous trajectory to a precise position within bone. The objective of this study was to assess the construct validity for a novel radiation-free simulator designed to teach wire navigation skills in hip fracture fixation. Methods Novices (N=30) with limited to no surgical experience in hip fracture fixation and experienced surgeons (N=10) participated. Participants drilled a guide wire in the center-center position of a synthetic femoral head in a hip fracture simulator, using electromagnetic sensors to track the guide wire position. Sensor data were gathered to generate fluoroscopic-like images of the hip and guide wire. Simulator performance of novice and experienced participants was compared to measure construct validity. Results The simulator was able to discriminate the accuracy in guide wire position between novices and experienced surgeons. Experienced surgeons achieved a more accurate tip-apex distance than novices (13 vs 23 mm, respectively, p=0.009). The magnitude of improvement on successive simulator attempts was dependent on level of expertise; tip-apex distance improved significantly in the novice group, while it was unchanged in the experienced group. Conclusions This hybrid reality, radiation-free hip fracture simulator, which combines real-world objects with computer-generated imagery demonstrates construct validity by distinguishing the performance of novices and experienced surgeons. There is a differential effect depending on level of experience, and it could be used as an effective training tool in novice surgeons. PMID:26165262
Schick, Fabian; Asseln, Malte; Damm, Philipp; Radermacher, Klaus
2018-01-01
Validation of musculoskeletal models for application in preoperative planning is still a challenging task. Ideally, the simulation results of a patient-specific musculoskeletal model are compared to corresponding in vivo measurements. Currently, the only possibility to measure in vivo joint forces is to implant an instrumented prosthesis in patients undergoing a total joint replacement. In this study, a musculoskeletal model of the AnyBody Modeling System was adapted patient-specifically and validated against the in vivo hip joint force measurements of ten subjects performing one-leg stance and level walking. The impact of four model parameters was evaluated; hip joint width, muscle strength, muscle recruitment, and type of muscle model. The smallest difference between simulated and in vivo hip joint force was achieved by using the hip joint width measured in computed tomography images, a muscle strength of 90 N/cm2, a third order polynomial muscle recruitment, and a simple muscle model. This parameter combination reached mean deviations between simulation and in vivo measurement during the peak force phase of 12% ± 14% in magnitude and 11° ± 5° in orientation for one-leg stance and 8% ± 6% in magnitude and 10° ± 5° in orientation for level walking. PMID:29649235
Partridge, Susan; Tipper, Joanne L; Al-Hajjar, Mazen; Isaac, Graham H; Fisher, John; Williams, Sophie
2018-05-01
Wear and fatigue of polyethylene acetabular cups have been reported to play a role in the failure of total hip replacements. Hip simulator testing under a wide range of clinically relevant loading conditions is important. Edge loading of hip replacements can occur following impingement under extreme activities and can also occur during normal gait, where there is an offset deficiency and/or joint laxity. This study evaluated a hip simulator method that assessed wear and damage in polyethylene acetabular liners that were subjected to edge loading. The liners tested to evaluate the method were a currently manufactured crosslinked polyethylene acetabular liner and an aged conventional polyethylene acetabular liner. The acetabular liners were tested for 5 million standard walking cycles and following this 5 million walking cycles with edge loading. Edge loading conditions represented a separation of the centers of rotation of the femoral head and the acetabular liner during the swing phase, leading to loading of the liner rim on heel strike. Rim damage and cracking was observed in the aged conventional polyethylene liner. Steady-state wear rates assessed gravimetrically were lower under edge loading compared to standard loading. This study supports previous clinical findings that edge loading may cause rim cracking in liners, where component positioning is suboptimal or where material degradation is present. The simulation method developed has the potential to be used in the future to test the effect of aging and different levels of severity of edge loading on a range of cross-linked polyethylene materials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1456-1462, 2018. © 2017 Wiley Periodicals, Inc.
Li, Junyan; Stewart, Todd D.; Jin, Zhongmin; Wilcox, Ruth K.; Fisher, John
2013-01-01
Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000 s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future. PMID:23664238
Chang, Chia-Yuan; Rupp, Jonathan D; Reed, Matthew P; Hughes, Richard E; Schneider, Lawrence W
2009-11-01
In a previous study, the authors reported on the development of a finite-element model of the midsize male pelvis and lower extremities with lower-extremity musculature that was validated using PMHS knee-impact response data. Knee-impact simulations with this model were performed using forces from four muscles in the lower extremities associated with two-foot bracing reported in the literature to provide preliminary estimates of the effects of lower-extremity muscle activation on knee-thigh-hip injury potential in frontal impacts. The current study addresses a major limitation of these preliminary simulations by using the AnyBody three-dimensional musculoskeletal model to estimate muscle forces produced in 35 muscles in each lower extremity during emergency one-foot braking. To check the predictions of the AnyBody Model, activation levels of twelve major muscles in the hip and lower extremities were measured using surface EMG electrodes on 12 midsize-male subjects performing simulated maximum and 50% of maximum braking in a laboratory seating buck. Comparisons between test results and the predictions of the AnyBody Model when it was used to simulate these same braking tests suggest that the AnyBody model appropriately predicts agonistic muscle activations but under predicts antagonistic muscle activations. Simulations of knee-to-knee-bolster impacts were performed by impacting the knees of the lower-extremity finite element model with and without the muscle forces predicted by the validated AnyBody Model. Results of these simulations confirm previous findings that muscle tension increases knee-impact force by increasing the effective mass of the KTH complex due to tighter coupling of muscle mass to bone. They also indicate that muscle activation preferentially couples mass distal to the hip, thereby accentuating the decrease in femur force from the knee to the hip. However, the reduction in force transmitted from the knee to the hip is offset by the increased force at the knee and by increased compressive forces at the hip due to activation of lower-extremity muscles. As a result, approximately 45% to 60% and 50% to 65% of the force applied to the knee is applied to the hip in the simulations without and with muscle tension, respectively. The simulation results suggest that lower-extremity muscle tension has little effect on the risk of hip injuries, but it increases the bending moments in the femoral shaft, thereby increasing the risk of femoral shaft fractures by 20%-40%. However, these findings may be affected by the inability of the AnyBody Model to appropriately predict antagonistic muscle forces.
Importance of preclinical evaluation of wear in hip implant designs using simulator machines.
Trommer, Rafael Mello; Maru, Márcia Marie
2017-01-01
Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.
Testing the Construct Validity of a Virtual Reality Hip Arthroscopy Simulator.
Khanduja, Vikas; Lawrence, John E; Audenaert, Emmanuel
2017-03-01
To test the construct validity of the hip diagnostics module of a virtual reality hip arthroscopy simulator. Nineteen orthopaedic surgeons performed a simulated arthroscopic examination of a healthy hip joint using a 70° arthroscope in the supine position. Surgeons were categorized as either expert (those who had performed 250 hip arthroscopies or more) or novice (those who had performed fewer than this). Twenty-one specific targets were visualized within the central and peripheral compartments; 9 via the anterior portal, 9 via the anterolateral portal, and 3 via the posterolateral portal. This was immediately followed by a task testing basic probe examination of the joint in which a series of 8 targets were probed via the anterolateral portal. During the tasks, the surgeon's performance was evaluated by the simulator using a set of predefined metrics including task duration, number of soft tissue and bone collisions, and distance travelled by instruments. No repeat attempts at the tasks were permitted. Construct validity was then evaluated by comparing novice and expert group performance metrics over the 2 tasks using the Mann-Whitney test, with a P value of less than .05 considered significant. On the visualization task, the expert group outperformed the novice group on time taken (P = .0003), number of collisions with soft tissue (P = .001), number of collisions with bone (P = .002), and distance travelled by the arthroscope (P = .02). On the probe examination, the 2 groups differed only in the time taken to complete the task (P = .025) with no significant difference in other metrics. Increased experience in hip arthroscopy was reflected by significantly better performance on the virtual reality simulator across 2 tasks, supporting its construct validity. This study validates a virtual reality hip arthroscopy simulator and supports its potential for developing basic arthroscopic skills. Level III. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.
Li, Junyan; Stewart, Todd D; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John
2013-06-21
Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Barbour, P S; Stone, M H; Fisher, J
1999-01-01
In some designs of hip joint simulator the cost of building a highly complex machine has been offset with the requirement for a large number of test stations. The application of the wear results generated by these machines depends on their ability to reproduce physiological wear rates and processes. In this study a hip joint simulator has been shown to reproduce physiological wear using only one load vector and two degrees of motion with simplified input cycles. The actual path of points on the femoral head relative to the acetabular cup were calculated and compared for physiological and simplified input cycles. The in vitro wear rates were found to be highly dependent on the shape of these paths and similarities could be drawn between the shape of the physiological paths and the simplified elliptical paths.
Higashi, Hideki; Barendregt, Jan J.
2011-01-01
Background Osteoarthritis constitutes a major musculoskeletal burden for the aged Australians. Hip and knee replacement surgeries are effective interventions once all conservative therapies to manage the symptoms have been exhausted. This study aims to evaluate the cost-effectiveness of hip and knee replacements in Australia. To our best knowledge, the study is the first attempt to account for the dual nature of hip and knee osteoarthritis in modelling the severities of right and left joints separately. Methodology/Principal Findings We developed a discrete-event simulation model that follows up the individuals with osteoarthritis over their lifetimes. The model defines separate attributes for right and left joints and accounts for several repeat replacements. The Australian population with osteoarthritis who were 40 years of age or older in 2003 were followed up until extinct. Intervention effects were modelled by means of disability-adjusted life-years (DALYs) averted. Both hip and knee replacements are highly cost effective (AUD 5,000 per DALY and AUD 12,000 per DALY respectively) under an AUD 50,000/DALY threshold level. The exclusion of cost offsets, and inclusion of future unrelated health care costs in extended years of life, did not change the findings that the interventions are cost-effective (AUD 17,000 per DALY and AUD 26,000 per DALY respectively). However, there was a substantial difference between hip and knee replacements where surgeries administered for hips were more cost-effective than for knees. Conclusions/Significance Both hip and knee replacements are cost-effective interventions to improve the quality of life of people with osteoarthritis. It was also shown that the dual nature of hip and knee OA should be taken into account to provide more accurate estimation on the cost-effectiveness of hip and knee replacements. PMID:21966520
Numerical simulation of artificial hip joint motion based on human age factor
NASA Astrophysics Data System (ADS)
Ramdhani, Safarudin; Saputra, Eko; Jamari, J.
2018-05-01
Artificial hip joint is a prosthesis (synthetic body part) which usually consists of two or more components. Replacement of the hip joint due to the occurrence of arthritis, ordinarily patients aged or older. Numerical simulation models are used to observe the range of motion in the artificial hip joint, the range of motion of joints used as the basis of human age. Finite- element analysis (FEA) is used to calculate stress von mises in motion and observes a probability of prosthetic impingement. FEA uses a three-dimensional nonlinear model and considers the position variation of acetabular liner cups. The result of numerical simulation shows that FEA method can be used to analyze the performance calculation of the artificial hip joint at this time more accurate than conventional method.
Liebl, Hans; Garcia, Eduardo Grande; Holzner, Fabian; Noel, Peter B.; Burgkart, Rainer; Rummeny, Ernst J.; Baum, Thomas; Bauer, Jan S.
2015-01-01
Purpose To experimentally validate a non-linear finite element analysis (FEA) modeling approach assessing in-vitro fracture risk at the proximal femur and to transfer the method to standard in-vivo multi-detector computed tomography (MDCT) data of the hip aiming to predict additional hip fracture risk in subjects with and without osteoporosis associated vertebral fractures using bone mineral density (BMD) measurements as gold standard. Methods One fresh-frozen human femur specimen was mechanically tested and fractured simulating stance and clinically relevant fall loading configurations to the hip. After experimental in-vitro validation, the FEA simulation protocol was transferred to standard contrast-enhanced in-vivo MDCT images to calculate individual hip fracture risk each for 4 subjects with and without a history of osteoporotic vertebral fractures matched by age and gender. In addition, FEA based risk factor calculations were compared to manual femoral BMD measurements of all subjects. Results In-vitro simulations showed good correlation with the experimentally measured strains both in stance (R2 = 0.963) and fall configuration (R2 = 0.976). The simulated maximum stress overestimated the experimental failure load (4743 N) by 14.7% (5440 N) while the simulated maximum strain overestimated by 4.7% (4968 N). The simulated failed elements coincided precisely with the experimentally determined fracture locations. BMD measurements in subjects with a history of osteoporotic vertebral fractures did not differ significantly from subjects without fragility fractures (femoral head: p = 0.989; femoral neck: p = 0.366), but showed higher FEA based risk factors for additional incident hip fractures (p = 0.028). Conclusion FEA simulations were successfully validated by elastic and destructive in-vitro experiments. In the subsequent in-vivo analyses, MDCT based FEA based risk factor differences for additional hip fractures were not mirrored by according BMD measurements. Our data suggests, that MDCT derived FEA models may assess bone strength more accurately than BMD measurements alone, providing a valuable in-vivo fracture risk assessment tool. PMID:25723187
Jonkers, Ilse; De Schutter, Joris; De Groote, Friedl
2016-01-01
Experimental studies have shown that a continuum of ankle and hip strategies is used to restore posture following an external perturbation. Postural responses can be modeled by feedback control with feedback gains that optimize a specific objective. On the one hand, feedback gains that minimize effort have been used to predict muscle activity during perturbed standing. On the other hand, hip and ankle strategies have been predicted by minimizing postural instability and deviation from upright posture. It remains unclear, however, whether and how effort minimization influences the selection of a specific postural response. We hypothesize that the relative importance of minimizing mechanical work vs. postural instability influences the strategy used to restore upright posture. This hypothesis was investigated based on experiments and predictive simulations of the postural response following a backward support surface translation. Peak hip flexion angle was significantly correlated with three experimentally determined measures of effort, i.e., mechanical work, mean muscle activity and metabolic energy. Furthermore, a continuum of ankle and hip strategies was predicted in simulation when changing the relative importance of minimizing mechanical work and postural instability, with increased weighting of mechanical work resulting in an ankle strategy. In conclusion, the combination of experimental measurements and predictive simulations of the postural response to a backward support surface translation showed that the trade-off between effort and postural instability minimization can explain the selection of a specific postural response in the continuum of potential ankle and hip strategies. PMID:27489362
Simoes, Thiago A; Bryant, Michael G; Brown, Andy P; Milne, Steven J; Ryan, Mary; Neville, Anne; Brydson, Rik
2016-11-01
We have characterized CoCrMo, Metal-on-Metal (MoM) implant, wear debris particles and their dissolution following cycling in a hip simulator, and have related the results to the tribocorrosion of synthetic wear debris produced by milling CoCrMo powders in solutions representative of environments in the human body. Importantly, we have employed a modified ICP-MS sample preparation procedure to measure the release of ions from CoCrMo alloys during wear simulation in different media; this involved use of nano-porous ultrafilters which allowed complete separation of particles from free ions and complexes in solution. As a result, we present a new perspective on the release of metal ions and formation of metal complexes from CoCrMo implants. The new methodology enables the mass balance of ions relative to complexes and particles during tribocorrosion in hip simulators to be determined. A much higher release of molybdenum ions relative to cobalt and chromium has been measured. The molybdenum dissolution was enhanced by the presence of bovine serum albumin (BSA), possibly due to the formation of metal-protein complexes. Overall, we believe that the results could have significant implications for the analysis and interpretation of metal ion levels in fluids extracted from hip arthroplasty patients; we suggest that metal levels, including molybdenum, be analysed in these fluids using the protocol described here. We have developed an important new protocol for the analysis of metal ion levels in fluids extracted from hip implant patients and also hip simulators. Using this procedure, we present a new perspective on the release of metal ions from CoCrMo alloy implants, revealing significantly lower levels of metal ion release during tribocorrosion in hip simulators than previously thought, combined with the release of much higher percentages of molybdenum ions relative to cobalt and chromium. This work is of relevance, both from the perspective of the fundamental science and study of metal-protein interactions, enabling understanding of the ongoing problem associated with the biotribocorrosion and the link to inflammation associated with Metal-on-Metal (MoM) hip implants made from CoCrMo alloys. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Effect of motion inputs on the wear prediction of artificial hip joints
Liu, Feng; Fisher, John; Jin, Zhongmin
2013-01-01
Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear modelling has been improved recently for the conventional UHMWPE used in total hip joint replacements. A new polyethylene wear law is an explicit function of the contact area of the bearing and the sliding distance, and the effect of multidirectional motion on wear has been quantified by a factor, cross-shear ratio. In this study, the full simulated walking cycle condition based on a walking measurement and two simplified motions, including the ISO standard motion and a simplified ProSim hip simulator motion, were considered as the inputs for wear modelling based on the improved wear model. Both the full simulation and simplified motions generated the comparable multidirectional motion required to reproduce the physiological wear of the bearing in vivo. The predicted volumetric wear of the ProSim simulator motion and the ISO motion conditions for the walking cycle were 13% and 4% lower, respectively, than that of the measured walking condition. The maximum linear wear depths were almost the same, and the areas of the wear depth distribution were 13% and 7% lower for the ProSim simulator and the ISO condition, respectively, compared with that of the measured walking cycle motion condition. PMID:25540472
Study of scattered radiation during fluoroscopy in hip surgery*
Lesyuk, Oksana; Sousa, Patrick Emmanuel; Rodrigues, Sónia Isabel do Espirito Santo; Abrantes, António Fernando; de Almeida, Rui Pedro Pereira; Pinheiro, João Pedro; Azevedo, Kevin Barros; Ribeiro, Luís Pedro Vieira
2016-01-01
Objective To measure the scattered radiation dose at different positions simulating hip surgery. Materials and Methods We simulated fluoroscopy-assisted hip surgery in order to study the distribution of scattered radiation in the operating room. To simulate the patient, we used a anthropomorphic whole-body phantom, and we used an X-ray-specific detector to quantify the radiation. Radiographs were obtained with a mobile C-arm X-ray system in continuous scan mode, with the tube at 0º (configuration 1) or 90º (configuration 2). The operating parameters employed (voltage, current, and exposure time) were determined by a statistical analysis based on the observation of orthopedic surgical procedures involving the hip. Results For all measurements, higher exposures were observed in configuration 2. In the measurements obtained as a function of height, the maximum dose rates observed were 1.167 (± 0.023) µSv/s and 2.278 (± 0.023) µSv/s in configurations 1 and 2, respectively, corresponding to the chest level of health care professionals within the operating room. Proximal to the patient, the maximum values were recorded in the position occupied by the surgeon. Conclusion We can conclude that, in the scenario under study, health care professionals workers are exposed to low levels of radiation, and that those levels can be reduced through the use of personal protective equipment. PMID:27777477
Tribological performance of the biological components of synovial fluid in artificial joint implants
NASA Astrophysics Data System (ADS)
Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Moradi, Ali; Masjuki, H. H.; Pingguan-Murphy, Belinda
2015-08-01
The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient.
Gait alterations to effectively reduce hip contact forces.
Wesseling, Mariska; de Groote, Friedl; Meyer, Christophe; Corten, Kristoff; Simon, Jean-Pierre; Desloovere, Kaat; Jonkers, Ilse
2015-07-01
Patients with hip pathology present alterations in gait which have an effect on joint moments and loading. In knee osteoarthritic patients, the relation between medial knee contact forces and the knee adduction moment are currently being exploited to define gait retraining strategies to effectively reduce pain and disease progression. However, the relation between hip contact forces and joint moments has not been clearly established. Therefore, this study aims to investigate the effect of changes in hip and pelvis kinematics during gait on internal hip moments and contact forces which is calculated using muscle driven simulations. The results showed that frontal plane kinetics have the largest effect on hip contact forces. Given the high correlation between the change in hip adduction moment and contact force at initial stance (R(2) = 0.87), this parameter can be used to alter kinematics and predict changes in contact force. At terminal stance the hip adduction and flexion moment can be used to predict changes in contact force (R(2) = 0.76). Therefore, gait training that focuses on decreasing hip adduction moments, a wide base gait pattern, has the largest potential to reduce hip contact forces. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Akhtar, Kashif; Sugand, Kapil; Sperrin, Matthew; Cobb, Justin; Standfield, Nigel; Gupte, Chinmay
2015-01-01
Virtual-reality (VR) simulation in orthopedic training is still in its infancy, and much of the work has been focused on arthroscopy. We evaluated the construct validity of a new VR trauma simulator for performing dynamic hip screw (DHS) fixation of a trochanteric femoral fracture. 30 volunteers were divided into 3 groups according to the number of postgraduate (PG) years and the amount of clinical experience: novice (1-4 PG years; less than 10 DHS procedures); intermediate (5-12 PG years; 10-100 procedures); expert (> 12 PG years; > 100 procedures). Each participant performed a DHS procedure and objective performance metrics were recorded. These data were analyzed with each performance metric taken as the dependent variable in 3 regression models. There were statistically significant differences in performance between groups for (1) number of attempts at guide-wire insertion, (2) total fluoroscopy time, (3) tip-apex distance, (4) probability of screw cutout, and (5) overall simulator score. The intermediate group performed the procedure most quickly, with the lowest fluoroscopy time, the lowest tip-apex distance, the lowest probability of cutout, and the highest simulator score, which correlated with their frequency of exposure to running the trauma lists for hip fracture surgery. This study demonstrates the construct validity of a haptic VR trauma simulator with surgeons undertaking the procedure most frequently performing best on the simulator. VR simulation may be a means of addressing restrictions on working hours and allows trainees to practice technical tasks without putting patients at risk. The VR DHS simulator evaluated in this study may provide valid assessment of technical skill.
Li, Ning; Tsushima, Eiki; Tsushima, Hitoshi
2013-04-05
Use of hip protectors and compliant flooring has been recommended for preventing hip fracture due to falls. We aimed to identify the factors attenuating forces in falls by comparing and analyzing the impact forces occurring with various combinations of hip protectors and flooring materials. We designed a simplified pendulum device to simulate the impact force at the hip during falling. The impact force was measured on pressure-sensitive recording film under combined conditions of two kinds of hip protector (hard or soft shell) and three kinds of floor material (concrete, wooden, or tatami matting). We then calculated the percentage force attenuation under each test condition compared with the use of a concrete floor and no hip protector. All the tests using tatami matting reduced the impact to below the average fracture threshold of elderly people (3472N). A combination of tatami and soft hip protector provided the best attenuation (72.5%). Multiple regression analyses showed that use of tatami matting and a soft hip protector had the biggest force-attenuation effect. The soft hip protector gave better percentage force attenuation than did the hard one. Use of tatami matting as a flooring material could be an effective strategy for helping prevent hip fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.
Effect of ion implantation on the tribology of metal-on-metal hip prostheses.
Bowsher, John G; Hussain, Azad; Williams, Paul; Nevelos, Jim; Shelton, Julia C
2004-12-01
Nitrogen ion implantation (which considerably hardens the surface of the bearing) may represent one possible method of reducing the wear of metal-on-metal (MOM) hip bearings. Currently there are no ion-implanted MOM bearings used clinically. Therefore a physiological hip simulator test was undertaken using standard test conditions, and the results compared to previous studies using the same methods. N2-ion implantation of high carbon cast Co-Cr-Mo-on-Co-Cr-Mo hip prostheses increased wear by 2-fold during the aggressive running-in phase compared to untreated bearing surfaces, plus showing no wear reductions during steady-state conditions. Although 2 specimens were considered in the current study, it would appear that ion implantation has no clinical benefit for MOM.
Vassiliou, K; Elfick, A P D; Scholes, S C; Unsworth, A
2006-02-01
It is well documented that hard bearing combinations show a running-in phenomenon in vitro and there is also some evidence of this from retrieval studies. In order to investigate this phenomenon, five Birmingham hip resurfacing devices were tested in a hip wear simulator. One of these (joint 1) was also tested in a friction simulator before, during, and after the wear test and surface analysis was conducted throughout portions of the testing. The wear showed the classical running in with the wear rate falling from 1.84 mm3 per 10(6) cycles for the first 10(6) cycles of testing to 0.24 mm3 per 10(6) cycles over the final 2 x 10(6) cycles of testing. The friction tests suggested boundary lubrication initially, but at 1 x 10(6) cycles a mixed lubrication regime was evident. By 2 x 10(6) cycles the classical Stribeck curve had formed, indicating a considerable contribution from the fluid film at higher viscosities. This continued to be evident at both 3 x 10(6) and 5 x 10(6) cycles. The surface study complements these findings.
Computational Modelling and Movement Analysis of Hip Joint with Muscles
NASA Astrophysics Data System (ADS)
Siswanto, W. A.; Yoon, C. C.; Salleh, S. Md.; Ngali, M. Z.; Yusup, Eliza M.
2017-01-01
In this study, the model of hip joint and the main muscles are modelled by finite elements. The parts included in the model are hip joint, hemi pelvis, gluteus maximus, quadratus femoris and gamellus inferior. The materials that used in these model are isotropic elastic, Mooney Rivlin and Neo-hookean. The hip resultant force of the normal gait and stair climbing are applied on the model of hip joint. The responses of displacement, stress and strain of the muscles are then recorded. FEBio non-linear solver for biomechanics is employed to conduct the simulation of the model of hip joint with muscles. The contact interfaces that used in this model are sliding contact and tied contact. From the analysis results, the gluteus maximus has the maximum displacement, stress and strain in the stair climbing. Quadratus femoris and gamellus inferior has the maximum displacement and strain in the normal gait however the maximum stress in the stair climbing. Besides that, the computational model of hip joint with muscles is produced for research and investigation platform. The model can be used as a visualization platform of hip joint.
Modeling initial contact dynamics during ambulation with dynamic simulation.
Meyer, Andrew R; Wang, Mei; Smith, Peter A; Harris, Gerald F
2007-04-01
Ankle-foot orthoses are frequently used interventions to correct pathological gait. Their effects on the kinematics and kinetics of the proximal joints are of great interest when prescribing ankle-foot orthoses to specific patient groups. Mathematical Dynamic Model (MADYMO) is developed to simulate motor vehicle crash situations and analyze tissue injuries of the occupants based multibody dynamic theories. Joint kinetics output from an inverse model were perturbed and input to the forward model to examine the effects of changes in the internal sagittal ankle moment on knee and hip kinematics following heel strike. Increasing the internal ankle moment (augmentation, equivalent to gastroc-soleus contraction) produced less pronounced changes in kinematic results at the hip, knee and ankle than decreasing the moment (attenuation, equivalent to gastroc-soleus relaxation). Altering the internal ankle moment produced two distinctly different kinematic curve morphologies at the hip. Decreased internal ankle moments increased hip flexion, peaking at roughly 8% of the gait cycle. Increasing internal ankle moments decreased hip flexion to a lesser degree, and approached normal at the same point in the gait cycle. Increasing the internal ankle moment produced relatively small, well-behaved extension-biased kinematic results at the knee. Decreasing the internal ankle moment produced more substantial changes in knee kinematics towards flexion that increased with perturbation magnitude. Curve morphologies were similar to those at the hip. Immediately following heel strike, kinematic results at the ankle showed movement in the direction of the internal moment perturbation. Increased internal moments resulted in kinematic patterns that rapidly approach normal after initial differences. When the internal ankle moment was decreased, differences from normal were much greater and did not rapidly decrease. This study shows that MADYMO can be successfully applied to accomplish forward dynamic simulations, given kinetic inputs. Future applications include predicting muscle forces and decomposing external kinetics.
Gilleard, W; Smith, T
2007-02-01
Effects of obesity on trunk forward flexion motion in sitting and standing, and postural adaptations and hip joint moment for a standing work task. Cross-sectional comparison of obese and normal weight groups. Ten obese subjects (waist girth 121.2+/-16.8 cm, body mass index (BMI) 38.9+/-6.6 kg m(-2)) and 10 age- and height-matched normal weight subjects (waist girth 79.6+/-6.4 cm, BMI 21.7+/-1.5 kg m(-2)). Trunk motion during seated and standing forward flexion, and trunk posture, hip joint moment and hip-to-bench distance during a simulated standing work task were recorded. Forward flexion motion of the thoracic segment and thoracolumbar spine was decreased for the obese group with no change in pelvic segment and hip joint motion. Obese subjects showed a more flexed trunk posture and increased hip joint moment and hip-to-bench distance for a simulated standing work task. Decreased range of forward flexion motion, differing effects within the trunk, altered posture during a standing work task and concomitant increases in hip joint moment give insight into the aetiology of functional decrements and musculoskeletal pain seen in obesity.
NASA Astrophysics Data System (ADS)
Russ, Mark D.; Abel, Mark F.
1998-06-01
Five patients with cerebral palsy, hip dysplasia, pelvic obliquity, and scoliosis were evaluated retrospectively using three dimensional computed tomography (3DCT) scans of the proximal femur, pelvis, and lumbar spine to qualitatively evaluate their individual deformities by measuring a number of anatomical landmarks. Three dimensional reconstructions of the data were visualized, analyzed, and then manipulated interactively to perform simulated osteotomies of the proximal femur and pelvis to achieve surgical correction of the hip dysplasia. Severe deformity can occur in spastic cerebral palsy, with serious consequences for the quality of life of the affected individuals and their families. Controversy exists regarding the type, timing and efficacy of surgical intervention for correction of hip dysplasia in this population. Other authors have suggested 3DCT studies are required to accurately analyze acetabular deficiency, and that this data allows for more accurate planning of reconstructive surgery. It is suggested here that interactive manipulation of the data to simulate the proposed surgery is a clinically useful extension of the analysis process and should also be considered as an essential part of the pre-operative planning to assure that the appropriate procedure is chosen. The surgical simulation may reduce operative time and improve surgical correction of the deformity.
Design, simulation and modelling of auxiliary exoskeleton to improve human gait cycle.
Ashkani, O; Maleki, A; Jamshidi, N
2017-03-01
Exoskeleton is a walking assistance device that improves human gait cycle through providing auxiliary force and transferring physical load to the stronger muscles. This device takes the natural state of organ and follows its natural movement. Exoskeleton functions as an auxiliary device to help those with disabilities in hip and knee such as devotees, elderly farmers and agricultural machinery operators who suffer from knee complications. In this research, an exoskeleton designed with two screw jacks at knee and hip joints. To simulate extension and flexion movements of the leg joints, bearings were used at the end of hip and knee joints. The generated torque and motion angles of these joints obtained as well as the displacement curves of screw jacks in the gait cycle. Then, the human gait cycle was simulated in stance and swing phases and the obtained torque curves were compared. The results indicated that they followed the natural circle of the generated torque in joints with a little difference from each other. The maximum displacement obtained 4 and 6 cm in hip and knee joints jack respectively. The maximum torques in hip and knee joints were generated in foot contact phase. Also the minimum torques in hip and knee joints were generated in toe off and heel off phases respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Çatlı, Serap, E-mail: serapcatli@hotmail.com; Tanır, Güneş
2013-10-01
The present study aimed to investigate the effects of titanium, titanium alloy, and stainless steel hip prostheses on dose distribution based on the Monte Carlo simulation method, as well as the accuracy of the Eclipse treatment planning system (TPS) at 6 and 18 MV photon energies. In the present study the pencil beam convolution (PBC) method implemented in the Eclipse TPS was compared to the Monte Carlo method and ionization chamber measurements. The present findings show that if high-Z material is used in prosthesis, large dose changes can occur due to scattering. The variance in dose observed in the presentmore » study was dependent on material type, density, and atomic number, as well as photon energy; as photon energy increased back scattering decreased. The dose perturbation effect of hip prostheses was significant and could not be predicted accurately by the PBC method for hip prostheses. The findings show that for accurate dose calculation the Monte Carlo-based TPS should be used in patients with hip prostheses.« less
Structural materials by powder HIP for fusion reactors
NASA Astrophysics Data System (ADS)
Dellis, C.; Le Marois, G.; van Osch, E. V.
1998-10-01
Tokamak blankets have complex shapes and geometries with double curvature and embedded cooling channels. Usual manufacturing techniques such as forging, bending and welding generate very complex fabrication routes. Hot Isostatic Pressing (HIP) is a versatile and flexible fabrication technique that has a broad range of commercial applications. Powder HIP appears to be one of the most suitable techniques for the manufacturing of such complex shape components as fusion reactor modules. During the HIP cycle, consolidation of the powder is made and porosity in the material disappears. This involves a variation of 30% in volume of the component. These deformations are not isotropic due to temperature gradients in the part and the stiffness of the canister. This paper discusses the following points: (i) Availability of manufacturing process by powder HIP of 316LN stainless steel (ITER modules) and F82H martensitic steel (ITER Test Module and DEMO blanket) with properties equivalent to the forged one.(ii) Availability of powerful modelling techniques to simulate the densification of powder during the HIP cycle, and to control the deformation of components during consolidation by improving the canister design.(iii) Material data base needed for simulation of the HIP process, and the optimisation of canister geometry.(iv) Irradiation behaviour on powder HIP materials from preliminary results.
Finite element analysis of mechanical behavior of human dysplastic hip joints: a systematic review.
Vafaeian, B; Zonoobi, D; Mabee, M; Hareendranathan, A R; El-Rich, M; Adeeb, S; Jaremko, J L
2017-04-01
Developmental dysplasia of the hip (DDH) is a common condition predisposing to osteoarthritis (OA). Especially since DDH is best identified and treated in infancy before bones ossify, there is surprisingly a near-complete absence of literature examining mechanical behavior of infant dysplastic hips. We sought to identify current practice in finite element modeling (FEM) of DDH, to inform future modeling of infant dysplastic hips. We performed multi-database systematic review using PRISMA criteria. Abstracts (n = 126) fulfilling inclusion criteria were screened for methodological quality, and results were analyzed and summarized for eligible articles (n = 12). The majority of the studies modeled human adult dysplastic hips. Two studies focused on etiology of DDH through simulating mechanobiological growth of prenatal hips; we found no FEM-based studies in infants or children. Finite element models used either patient-specific geometry or idealized average geometry. Diversities in choice of material properties, boundary conditions, and loading scenarios were found in the finite-element models. FEM of adult dysplastic hips demonstrated generally smaller cartilage contact area in dysplastic hips than in normal joints. Contact pressure (CP) may be higher or lower in dysplastic hips depending on joint geometry and mechanical contribution of labrum (Lb). FEM of mechanobiological growth of prenatal hip joints revealed evidence for effects of the joint mechanical environment on formation of coxa valga, asymmetrically shallow acetabulum and malformed femoral head associated with DDH. Future modeling informed by the results of this review may yield valuable insights into optimal treatment of DDH, and into how and why OA develops early in DDH. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Beselga, Carlos; Neto, Francisco; Alburquerque-Sendín, Francisco; Hall, Toby; Oliveira-Campelo, Natália
2016-04-01
Mobilization with movement (MWM) has been shown to reduce pain, increase range of motion (ROM) and physical function in a range of different musculoskeletal disorders. Despite this evidence, there is a lack of studies evaluating the effects of MWM for hip osteoarthritis (OA). To determine the immediate effects of MWM on pain, ROM and functional performance in patients with hip OA. Randomized controlled trial with immediate follow-up. Forty consenting patients (mean age 78 ± 6 years; 54% female) satisfied the eligibility criteria. All participants completed the study. Two forms of MWM techniques (n = 20) or a simulated MWM (sham) (n = 20) were applied. pain recorded by numerical rating scale (NRS). hip flexion and internal rotation ROM, and physical performance (timed up and go, sit to stand, and 40 m self placed walk test) were assessed before and after the intervention. For the MWM group, pain decreased by 2 points on the NRS, hip flexion increased by 12.2°, internal rotation by 4.4°, and functional tests were also improved with clinically relevant effects following the MWM. There were no significant changes in the sham group for any outcome variable. Pain, hip flexion ROM and physical performance immediately improved after the application of MWM in elderly patients suffering hip OA. The observed immediate changes were of clinical relevance. Future studies are required to determine the long-term effects of this intervention. Copyright © 2015 Elsevier Ltd. All rights reserved.
Nasiri, Masoud; Luo, Yunhua
2016-09-01
There is controversy about whether or not body parameters affect hip fracture in men and women in the same way. In addition, although bone mineral density (BMD) is currently the most important single discriminator of hip fracture, it is unclear if BMD alone is equally effective for men and women. The objective of this study was to quantify and compare the associations of hip fracture risk with BMD and body parameters in men and women using our recently developed two-level biomechanical model that combines a whole-body dynamics model with a proximal-femur finite element model. Sideways fall induced impact force of 130 Chinese clinical cases, including 50 males and 80 females, were determined by subject-specific dynamics modeling. Then, a DXA-based finite element model was used to simulate the femur bone under the fall-induced loading conditions and calculate the hip fracture risk. Body weight, body height, body mass index, trochanteric soft tissue thickness, and hip bone mineral density were determined for each subject and their associations with impact force and hip fracture risk were quantified. Results showed that the association between impact force and hip fracture risk was not strong enough in both men (r=-0.31,p<0.05) and women (r=0.42,p<0.001) to consider the force as a sole indicator of hip fracture risk. The correlation between hip BMD and hip fracture risk in men (r=-0.83,p<0.001) was notably stronger than that in women (r=-0.68,p<0.001). Increased body mass index was not a protective factor against hip fracture in men (r=-0.13,p>0.05), but it can be considered as a protective factor among women (r=-0.28,p<0.05). In contrast to men, trochanteric soft tissue thickness can be considered as a protective factor against hip fracture in women (r=-0.50,p<0.001). This study suggested that the biomechanical risk/protective factors for hip fracture are sex-specific. Therefore, the effect of body parameters should be considered differently for men and women in hip fracture risk assessment tools. These findings support further exploration of sex-specific preventive and protective measurements to reduce the incidence of hip fractures. Copyright © 2016 Elsevier Inc. All rights reserved.
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH.
Royhman, Dmitry; Patel, Megha; Jacobs, Joshua J; Wimmer, Markus A; Hallab, Nadim J; Mathew, Mathew T
2018-02-01
The fretting-corrosion behavior of mixed metal contacts is affected by various mechanical and electrochemical parameters. Crevice conditions at the junction and patient-specific pathologies can affect the pH of the prosthetic environment. The main objective of this study is to understand the effect of pH variation at the stem/head junction of the hip implant under fretting corrosion exposure. We hypothesized that pH will have a significant influence on the fretting-corrosion behavior hip implant modular junctions. A custom-made setup was used to evaluate the fretting corrosion behavior of hip implant modular junctions. A Newborn calf serum solution (30 g/L protein content) was used to simulate the synovial fluid environment. A sinusoidal fretting motion, with a displacement amplitude of +50 µm, was applied to the Ti alloy rod. The effects of pathology driven, periprosthetic pH variation were simulated at four different pH levels (3.0, 4.5, 6.0 and 7.6). Electrochemical and mechanical properties were evaluated before, during, and after the applied fretting motion. The impedance of the system was increased in response to the fretting motion. The hysteresis tangential load/displacement behavior was not affected by pH level. The worn surfaces of CoCrMo pins exhibited the presence of tribolayer or organic deposits, in the pH 4.5 group, which may explain the lower drop in potential and mass loss observed in that group. Mechanically dominated wear mechanisms, namely, adhesive wear was shown in the pH 7.6 group, which may account for a higher potential drop and metal content loss. This study suggests that the fretting-corrosion mechanisms in hip implant are affected by the pH levels of the surrounding environment and patient-specific factors. Copyright © 2017. Published by Elsevier Ltd.
Three-dimensional friction measurement during hip simulation
Braun, Steffen; Al-Salehi, Loay; Reinders, Joern; Mueller, Ulrike; Kretzer, J. Philippe
2017-01-01
Objectives Wear of total hip replacements has been the focus of many studies. However, frictional effects, such as high loading on intramodular connections or the interface to the bone, as well as friction associated squeaking have recently increased interest about the amount of friction that is generated during daily activities. The aim of this study was thus to establish and validate a three-dimensional friction setup under standardized conditions. Materials and methods A standard hip simulator was modified to allow for high precision measurements of small frictional effects in the hip during three-dimensional hip articulation. The setup was verified by an ideal hydrostatic bearing and validated with a static-load physical pendulum and an extension-flexion rotation with a dynamic load profile. Additionally, a pendulum model was proposed for screening measurement of frictional effects based on the damping behavior of the angular oscillation without the need for any force/moment transducer. Finally, three-dimensional friction measurements have been realized for ceramic-on-polyethylene bearings of three different sizes (28, 36 and 40 mm). Results A precision of less than 0.2 Nm during three-dimensional friction measurements was reported, while increased frictional torque (resultant as well as taper torque) was measured for larger head diameters. These effects have been confirmed by simple pendulum tests and the theoretical model. A comparison with current literature about friction measurements is presented. Conclusions This investigation of friction is able to provide more information about a field that has been dominated by the reduction of wear. It should be considered in future pre-clinical testing protocols given by international organizations of standardization. PMID:28886102
Three-dimensional friction measurement during hip simulation.
Sonntag, Robert; Braun, Steffen; Al-Salehi, Loay; Reinders, Joern; Mueller, Ulrike; Kretzer, J Philippe
2017-01-01
Wear of total hip replacements has been the focus of many studies. However, frictional effects, such as high loading on intramodular connections or the interface to the bone, as well as friction associated squeaking have recently increased interest about the amount of friction that is generated during daily activities. The aim of this study was thus to establish and validate a three-dimensional friction setup under standardized conditions. A standard hip simulator was modified to allow for high precision measurements of small frictional effects in the hip during three-dimensional hip articulation. The setup was verified by an ideal hydrostatic bearing and validated with a static-load physical pendulum and an extension-flexion rotation with a dynamic load profile. Additionally, a pendulum model was proposed for screening measurement of frictional effects based on the damping behavior of the angular oscillation without the need for any force/moment transducer. Finally, three-dimensional friction measurements have been realized for ceramic-on-polyethylene bearings of three different sizes (28, 36 and 40 mm). A precision of less than 0.2 Nm during three-dimensional friction measurements was reported, while increased frictional torque (resultant as well as taper torque) was measured for larger head diameters. These effects have been confirmed by simple pendulum tests and the theoretical model. A comparison with current literature about friction measurements is presented. This investigation of friction is able to provide more information about a field that has been dominated by the reduction of wear. It should be considered in future pre-clinical testing protocols given by international organizations of standardization.
Medley, John B
2016-05-01
One of the most important mandates of physical joint simulators is to provide test results that allow the implant manufacturer to anticipate and perhaps avoid clinical wear problems with their new products. This is best done before market release. This study gives four steps to follow in conducting such wear simulator testing. Two major examples involving hip wear simulators are discussed in which attempts had been made to predict clinical wear performance prior to market release. The second one, involving the DePuy ASR implant systems, is chosen for more extensive treatment by making it an illustrative example to explore whether wear simulator testing can anticipate clinical wear problems. It is concluded that hip wear simulator testing did provide data in the academic literature that indicated some risk of clinical wear problems prior to market release of the ASR implant systems. This supports the idea that physical joint simulators have an important role in the pre-market testing of new joint replacement implants. © IMechE 2016.
Identification of the contribution of the ankle and hip joints to multi-segmental balance control
2013-01-01
Background Human stance involves multiple segments, including the legs and trunk, and requires coordinated actions of both. A novel method was developed that reliably estimates the contribution of the left and right leg (i.e., the ankle and hip joints) to the balance control of individual subjects. Methods The method was evaluated using simulations of a double-inverted pendulum model and the applicability was demonstrated with an experiment with seven healthy and one Parkinsonian participant. Model simulations indicated that two perturbations are required to reliably estimate the dynamics of a double-inverted pendulum balance control system. In the experiment, two multisine perturbation signals were applied simultaneously. The balance control system dynamic behaviour of the participants was estimated by Frequency Response Functions (FRFs), which relate ankle and hip joint angles to joint torques, using a multivariate closed-loop system identification technique. Results In the model simulations, the FRFs were reliably estimated, also in the presence of realistic levels of noise. In the experiment, the participants responded consistently to the perturbations, indicated by low noise-to-signal ratios of the ankle angle (0.24), hip angle (0.28), ankle torque (0.07), and hip torque (0.33). The developed method could detect that the Parkinson patient controlled his balance asymmetrically, that is, the right ankle and hip joints produced more corrective torque. Conclusion The method allows for a reliable estimate of the multisegmental feedback mechanism that stabilizes stance, of individual participants and of separate legs. PMID:23433148
Wang, Ling; Yang, Wenjian; Peng, Xifeng; Li, Dichen; Dong, Shuangpeng; Zhang, Shu; Zhu, Jinyu; Jin, Zhongmin
2015-04-13
The contact mechanics of artificial metal-on-polyethylene hip joints are believed to affect the lubrication, wear and friction of the articulating surfaces and may lead to the joint loosening. Finite element analysis has been widely used for contact mechanics studies and good agreements have been achieved with current experimental data; however, most studies were carried out with idealist spherical geometries of the hip prostheses rather than the realistic worn surfaces, either for simplification reason or lacking of worn surface profile. In this study, the worn surfaces of the samples from various stages of hip simulator testing (0 to 5 million cycles) were reconstructed as solid models and were applied in the contact mechanics study. The simulator testing results suggested that the center of the head has various departure value from that of the cup and the value of the departure varies with progressively increased wear. This finding was adopted into the finite element study for better evaluation accuracy. Results indicated that the realistic model provided different evaluation from that of the ideal spherical model. Moreover, with the progressively increased wear, large increase of the contact pressure (from 12 to 31 MPa) was predicted on the articulating surface, and the predicted maximum von Mises stress was increased from 7.47 to 13.26 MPa, indicating the marked effect of the worn surface profiles on the contact mechanics of the joint. This study seeks to emphasize the importance of realistic worn surface profile of the acetabular cup especially following large wear volume. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sugiura, Yusaku; Saito, Tomoyuki; Sakuraba, Keishoku; Sakuma, Kazuhiko; Suzuki, Eiichi
2008-08-01
Prospective cohort study. In this prospective cohort study of elite sprinters, muscle strength of the hip extensors, as well as of the knee extensors and flexors, was measured to determine a possible relationship between strength deficits and subsequent hamstring injury within 12 months of testing. The method used for testing muscle strength simulated the specific muscle action during late swing and early contact phases when sprinting. There have been no prospective studies in elite sprinters that examine the concentric and eccentric isokinetic strength of the hip extensors and the quadriceps and hamstring muscles in a manner that reflects their actions in late swing or early contact phases of sprinting. Consequently, the causal relationship between hip and thigh muscle strength and hamstring injury in elite sprinters may not be fully understood. Isokinetic testing was performed on 30 male elite sprinters to assess hip extensors, quadriceps, and hamstring muscle strength. The occurrence of hamstring injury among the subjects was determined during the year following the muscle strength measurements. The strength of the hip extensors, quadriceps, and hamstring muscles, as well as the hamstrings-quadriceps and hip extensors- quadriceps ratios were compared. Hamstring injury occurred in 6 subjects during the 1-year period. Isokinetic testing at a speed of 60 degrees /s revealed weakness of the injured limb with eccentric action of the hamstring muscles and during concentric action of the hip extensors. When performing a side-to-side comparison for the injured sprinters, the hamstring injury always occurred on the weaker side. Differences in the hamstrings-quadriceps and hip extensors-quadriceps strength ratios were also evident between uninjured and injured limbs, and this was attributable to deficits in hamstring strength. Hamstring injury in elite sprinters was associated with weakness during eccentric action of the hamstrings and weakness during concentric action of the hip extensors, but only when tested at the slower speed of 60 degrees /s.
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads.
Dembia, Christopher L; Silder, Amy; Uchida, Thomas K; Hicks, Jennifer L; Delp, Scott L
2017-01-01
Wearable robotic devices can restore and enhance mobility. There is growing interest in designing devices that reduce the metabolic cost of walking; however, designers lack guidelines for which joints to assist and when to provide the assistance. To help address this problem, we used musculoskeletal simulation to predict how hypothetical devices affect muscle activity and metabolic cost when walking with heavy loads. We explored 7 massless devices, each providing unrestricted torque at one degree of freedom in one direction (hip abduction, hip flexion, hip extension, knee flexion, knee extension, ankle plantarflexion, or ankle dorsiflexion). We used the Computed Muscle Control algorithm in OpenSim to find device torque profiles that minimized the sum of squared muscle activations while tracking measured kinematics of loaded walking without assistance. We then examined the metabolic savings provided by each device, the corresponding device torque profiles, and the resulting changes in muscle activity. We found that the hip flexion, knee flexion, and hip abduction devices provided greater metabolic savings than the ankle plantarflexion device. The hip abduction device had the greatest ratio of metabolic savings to peak instantaneous positive device power, suggesting that frontal-plane hip assistance may be an efficient way to reduce metabolic cost. Overall, the device torque profiles generally differed from the corresponding net joint moment generated by muscles without assistance, and occasionally exceeded the net joint moment to reduce muscle activity at other degrees of freedom. Many devices affected the activity of muscles elsewhere in the limb; for example, the hip flexion device affected muscles that span the ankle joint. Our results may help experimentalists decide which joint motions to target when building devices and can provide intuition for how devices may interact with the musculoskeletal system. The simulations are freely available online, allowing others to reproduce and extend our work.
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads
Silder, Amy; Uchida, Thomas K.; Hicks, Jennifer L.; Delp, Scott L.
2017-01-01
Wearable robotic devices can restore and enhance mobility. There is growing interest in designing devices that reduce the metabolic cost of walking; however, designers lack guidelines for which joints to assist and when to provide the assistance. To help address this problem, we used musculoskeletal simulation to predict how hypothetical devices affect muscle activity and metabolic cost when walking with heavy loads. We explored 7 massless devices, each providing unrestricted torque at one degree of freedom in one direction (hip abduction, hip flexion, hip extension, knee flexion, knee extension, ankle plantarflexion, or ankle dorsiflexion). We used the Computed Muscle Control algorithm in OpenSim to find device torque profiles that minimized the sum of squared muscle activations while tracking measured kinematics of loaded walking without assistance. We then examined the metabolic savings provided by each device, the corresponding device torque profiles, and the resulting changes in muscle activity. We found that the hip flexion, knee flexion, and hip abduction devices provided greater metabolic savings than the ankle plantarflexion device. The hip abduction device had the greatest ratio of metabolic savings to peak instantaneous positive device power, suggesting that frontal-plane hip assistance may be an efficient way to reduce metabolic cost. Overall, the device torque profiles generally differed from the corresponding net joint moment generated by muscles without assistance, and occasionally exceeded the net joint moment to reduce muscle activity at other degrees of freedom. Many devices affected the activity of muscles elsewhere in the limb; for example, the hip flexion device affected muscles that span the ankle joint. Our results may help experimentalists decide which joint motions to target when building devices and can provide intuition for how devices may interact with the musculoskeletal system. The simulations are freely available online, allowing others to reproduce and extend our work. PMID:28700630
Heidari, Behzad Shiroud; Davachi, Seyed Mohammad; Moghaddam, Amin Hedayati; Seyfi, Javad; Hejazi, Iman; Sahraeian, Razi; Rashedi, Hamid
2018-05-01
In this study, injection molding process of ultrahigh molecular weight polyethylene (UHMWPE) reinforced with nano-hydroxyapatite (nHA) was simulated and optimized through minimizing the shrinkage and warpage of the hip liners as an essential part of a hip prosthesis. Fractional factorial design (FFD) was applied to the design of the experiment, modeling, and optimizing the shrinkage and warpage of UHMWPE/nHA composite liners. The Analysis of variance (ANOVA) was applied to find the importance of operative parameters and their effects. In this experiment, seven input parameters were surveyed, including mold temperature (A), melt temperature (B), injection time (C), packing time (D), packing pressure (E), coolant temperature (F), and type of liner (G). Two models were capable of predicting warpage and volumetric shrinkage (%) in different conditions with R 2 of 0.9949 and 0.9989, respectively. According to the models, the optimized values of warpage and volumetric shrinkage are 0.287222 mm and 13.6613%, respectively. Meanwhile, a finite element analysis (FE analysis) was also carried out to examine the stress distribution in liners under the force values of demanding and daily activities. The Von-Mises stress distribution showed that both of the liners can be applied to all activities with no failure. However, UHMWPE/nHA liner is more resistant to the highest loads than UHMWPE liner due to the effect of nHA in the nanocomposite. Finally, according to the results of injection molding simulations, optimization, structural analysis as well as the tensile strength and wear resistance, UHMWPE/nHA liner is recommended for the production of a hip prosthesis. Copyright © 2018 Elsevier Ltd. All rights reserved.
Scheller, G; Schwarz, M; Früh, H J; Jani, L
1999-01-01
Hip simulator trials were conducted to determine the initial wear between alumina femoral heads and carbon fibre reinforced plastic (CFRP, CAPROMAN) insert in a titanium socket. A force of 2500 N and a frequency of 0.857 H were applied. Using surface and sphericity measurement techniques, the amount of wear was determined. After 500,000 cycles, the centre of the head had moved by 10 microm into the insert, and the average radius increased by 2 microm. After 1 million cycles, the additional changes were less than 1 microm. Based on an examination of retrieved implants (wear rate: 6.1 microm/year) and based on the simulator results, the combination alumina-CFRP inserts could be approved for total hip replacement.
Tribology and total hip joint replacement: current concepts in mechanical simulation.
Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M
2008-12-01
Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.
Gait alterations can reduce the risk of edge loading.
Wesseling, Mariska; Meyer, Christophe; De Groote, Friedl; Corten, Kristoff; Simon, Jean-Pierre; Desloovere, Kaat; Jonkers, Ilse
2016-06-01
Following metal-on-metal hip arthroplasty, edge loading (i.e., loading near the edge of a prosthesis cup) can increase wear and lead to early revision. The position and coverage angle of the prosthesis cup influence the risk of edge loading. This study investigates the effect of altered gait patterns, more specific hip, and pelvis kinematics, on the orientation of hip contact force and the consequent risk of antero-superior edge loading using muscle driven simulations of gait. With a cup orientation of 25° anteversion and 50° inclination and a coverage angle of 168°, many gait patterns presented risk of edge loading. Specifically at terminal double support, 189 out of 405 gait patterns indicated a risk of edge loading. At this time instant, the high hip contact forces and the proximity of the hip contact force to the edge of the cup indicated the likelihood of the occurrence of edge loading. Although the cup position contributed most to edge loading, altering kinematics considerably influenced the risk of edge loading. Increased hip abduction, resulting in decreasing hip contact force magnitude, and decreased hip extension, resulting in decreased risk on edge loading, are gait strategies that could prevent edge loading. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1069-1076, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Koelewijn, Anne D; van den Bogert, Antonie J
2016-09-01
Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.
Piriou, P; Ouenzerfi, G; Migaud, H; Renault, E; Massi, F; Serrault, M
2016-06-01
Modern ceramic (CoC) bearings for hip arthroplasty (THA) have been used in younger patients who expect improved survivorship. However, audible squeaking produced by the implant is an annoying complication. Previous numerical simulations were not able to accurately reproduce in vitro and in vivo observations. Therefore, we developed a finite element model to: (1) reproduce in vitro squeaking and validate the model by comparing it with in vivo recordings, (2) determine why there are differences between in vivo and in vitro squeaking frequencies, (3) identify the stem's role in this squeaking, (4) predict which designs and materials are more likely to produce squeaking. A CoC THA numerical model can be developed that reproduces the squeaking frequencies observed in vivo. Numerical methods (finite element analysis [ANSYS]) and experimental methods (using a non-lubricated simulated hip with a cementless 32mm CoC THA) were developed to reproduce squeaking. Numerical analysis was performed to identify the frequencies that cause vibrations perceived as an acoustic emission. The finite element analysis (FEA) model was enhanced by adjusting periprosthetic bone and soft tissue elements in order to reproduce the squeaking frequencies recorded in vivo. A numerical method (complex eigenvalue analysis) was used to find the acoustic frequencies of the squeaking noise. The frequencies obtained from the model and the hip simulator were compared to those recorded in vivo. The numerical results were validated by experiments with the laboratory hip simulator. The frequencies obtained (mean 2790Hz with FEA, 2755Hz with simulator, decreasing to 1759Hz when bone and soft tissue were included in the FEA) were consistent with those of squeaking hips recorded in vivo (1521Hz). The cup and ceramic insert were the source of the vibration, but had little influence on the diffusion of the noise required to make the squeaking audible to the human ear. The FEA showed that diffusion of squeaking was due to an unstable vibration of the stem during frictional contact. The FEA predicted a higher rate of squeaking (at a lower coefficient of friction) when TZMF™ alloy is used instead of Ti6Al4V and when an anatomic press-fit stem is used instead of straight self-locking designs. The current FEA model is reliable; it can be used to assess various stem designs and alloys to predict the different rates of squeaking that certain stems will likely produce. Level IV in vitro study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Influence of muscle groups' activation on proximal femoral growth tendency.
Yadav, Priti; Shefelbine, Sandra J; Pontén, Eva; Gutierrez-Farewik, Elena M
2017-12-01
Muscle and joint contact force influence stresses at the proximal growth plate of the femur and thus bone growth, affecting the neck shaft angle (NSA) and femoral anteversion (FA). This study aims to illustrate how different muscle groups' activation during gait affects NSA and FA development in able-bodied children. Subject-specific femur models were developed for three able-bodied children (ages 6, 7, and 11 years) using magnetic resonance images. Contributions of different muscle groups-hip flexors, hip extensors, hip adductors, hip abductors, and knee extensors-to overall hip contact force were computed. Specific growth rate for the growth plate was computed, and the growth was simulated in the principal stress direction at each element in the growth front. The predicted growth indicated decreased NSA and FA (of about [Formula: see text] over a four-month period) for able-bodied children. Hip abductors contributed the most, and hip adductors, the least, to growth rate. All muscles groups contributed to a decrease in predicted NSA ([Formula: see text]0.01[Formula: see text]-0.04[Formula: see text] and FA ([Formula: see text]0.004[Formula: see text]-[Formula: see text]), except hip extensors and hip adductors, which showed a tendency to increase the FA ([Formula: see text]0.004[Formula: see text]-[Formula: see text]). Understanding influences of different muscle groups on long bone growth tendency can help in treatment planning for growing children with affected gait.
Pretty, Steven P; Martel, Daniel R; Laing, Andrew C
2017-12-01
Hip fracture incidence rates are influenced by body mass index (BMI) and sex, likely through mechanistic pathways that influence dynamics of the pelvis-femur system during fall-related impacts. The goal of this study was to extend our understanding of these impact dynamics by investigating the effects of BMI, sex, and local muscle activation on pressure distribution over the hip region during lateral impacts. Twenty participants underwent "pelvis-release experiments" (which simulate a lateral fall onto the hip), including muscle-'relaxed' and 'contracted' trials. Males and low-BMI individuals exhibited 44 and 55% greater peak pressure, as well as 66 and 56% lower peripheral hip force, compared to females and high-BMI individuals, respectively. Local muscle activation increased peak force by 10%, contact area by 17%, and peripheral hip force by 11% compared to relaxed trials. In summary, males and low-BMI individuals exhibited more concentrated loading over the greater trochanter. Muscle activation increased peak force, but this force was distributed over a larger area, preventing increased localized loading over the greater trochanter. These findings suggest potential value in incorporating sex, gender, and muscle activation-specific force distributions as inputs into computational tissue-level models, and have implications for the design of personalized protective devices including wearable hip protectors.
Barbour, P S; Stone, M H; Fisher, J
2000-01-01
This study validates a hip joint simulator configuration as compared with other machines and clinical wear rates using smooth metal and ceramic femoral heads and ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. Secondly the wear rate of UHMWPE cups is measured in the simulator with deliberately scratched cobalt-chrome heads to represent the type of mild and severe scratch damage found on retrieved heads. Finally, the scratching processes are described and the resulting scratches compared with those found in retrieved cobalt-chrome heads. For smooth cobalt-chrome and zirconia heads the wear rates were found to be statistically similar to other simulator machines and within the normal range found from clinical studies. An increased wear rate was found with cobalt-chrome heads scratched using either the diamond stylus or the bead cobalt-chrome but the greatest increase was with the diamond scratched heads which generated scratches of similar dimensions to those on retrieved heads. A greater than twofold increase in wear rate is reported for these heads when compared with smooth heads. This increased wear rate is, however, still within the limits of data from clinical wear studies.
Ruan, Jesse S; El-Jawahri, Raed; Barbat, Saeed; Rouhana, Stephen W; Prasad, Priya
2008-11-01
Changes in vehicle safety design technology and the increasing use of seat-belts and airbag restraint systems have gradually changed the relative proportion of lower extremity injuries. These changes in real world injuries have renewed interest and the need of further investigation into occupant injury mechanisms and biomechanical impact responses of the knee-thigh-hip complex during frontal impacts. This study uses a detailed finite element model of the human body to simulate occupant knee impacts experienced in frontal crashes. The human body model includes detailed anatomical features of the head, neck, shoulder, chest, thoracic and lumbar spine, abdomen, pelvis, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The human body model used in the current study has been previously validated in frontal and side impacts. It was further validated with cadaver knee-thigh-hip impact tests in the current study. The effects of impactor configuration and flexion angle of the knee on biomechanical impact responses of the knee-thigh-hip complex were studied using the validated human body finite element model. This study showed that the knee flexion angle and the impact direction and shape of the impactors affected the injury outcomes of the knee-thigh-hip complex significantly. The 60 degrees flexed knee impact showed the least impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress but largest relative displacements of the Posterior Cruciate Ligament (PCL) and Anterior Cruciate Ligament (ACL). The 90 degrees flexed knee impact resulted in a higher impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress; but smaller PCL and ACL displacements. Stress distributions of the patella, femur, and pelvis were also given for all the simulated conditions.
Bougherara, Habiba; Zdero, Rad; Dubov, Anton; Shah, Suraj; Khurshid, Shaheen; Schemitsch, Emil H
2011-01-01
Total hip arthroplasty is a widespread surgical approach for treating severe osteoarthritis of the human hip. Aseptic loosening of standard metallic hip implants due to stress shielding and bone loss has motivated the development of new materials for hip prostheses. Numerically, a three-dimensional finite element (FE) model that mimicked hip implants was used to compare a new hip stem to two commercially available implants. The hip implants simulated were a novel CF/PA12 carbon-fibre polyamide-based composite hip stem, the Exeter hip stem (Stryker, Mahwah, NJ, USA), and the Omnifit Eon (Stryker, Mahwah, NJ, USA). A virtual axial load of 3 kN was applied to the FE model. Strain and stress distributions were computed. Experimentally, the three hip stems had their distal portions rigidly mounted and had strain gauges placed along the surface at 3 medial and 3 lateral locations. Axial loads of 3 kN were applied. Measurements of axial stiffness and strain were taken and compared to FE analysis. The overall linear correlation between FE model versus experimental strains showed reasonable results for the lines-of-best-fit for the Composite (Pearson R(2)=0.69, slope=0.82), Exeter (Pearson R(2)=0.78, slope=0.59), and Omnifit (Pearson R(2)=0.66, slope=0.45), with some divergence for the most distal strain locations. From FE analysis, the von Mises stress range for the Composite stem was much lower than that in the Omnifit and Exeter implants by 200% and 45%, respectively. The preliminary experiments showed that the Composite stem stiffness (1982 N/mm) was lower than the metallic hip stem stiffnesses (Exeter, 2460 N/mm; Omnifit, 2543 N/mm). This is the first assessment of stress, strain, and stiffness of the CF/PA12 carbon-fibre hip stem compared to standard commercially-available devices. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Cassereau, Didier; Nauleau, Pierre; Bendjoudi, Aniss; Minonzio, Jean-Gabriel; Laugier, Pascal; Bossy, Emmanuel; Grimal, Quentin
2014-07-01
The development of novel quantitative ultrasound (QUS) techniques to measure the hip is critically dependent on the possibility to simulate the ultrasound propagation. One specificity of hip QUS is that ultrasounds propagate through a large thickness of soft tissue, which can be modeled by a homogeneous fluid in a first approach. Finite difference time domain (FDTD) algorithms have been widely used to simulate QUS measurements but they are not adapted to simulate ultrasonic propagation over long distances in homogeneous media. In this paper, an hybrid numerical method is presented to simulate hip QUS measurements. A two-dimensional FDTD simulation in the vicinity of the bone is coupled to the semi-analytic calculation of the Rayleigh integral to compute the wave propagation between the probe and the bone. The method is used to simulate a setup dedicated to the measurement of circumferential guided waves in the cortical compartment of the femoral neck. The proposed approach is validated by comparison with a full FDTD simulation and with an experiment on a bone phantom. For a realistic QUS configuration, the computation time is estimated to be sixty times less with the hybrid method than with a full FDTD approach. Copyright © 2013 Elsevier B.V. All rights reserved.
Return to Driving After Hip Arthroscopy.
Momaya, Amit M; Stavrinos, Despina; McManus, Benjamin; Wittig, Shannon M; Emblom, Benton; Estes, Reed
2018-05-01
The objective of this study was to evaluate patients' braking performance using a modern driving simulator after undergoing a right hip arthroscopy. This prospective study included 5 total driving sessions at which measurements were taken. The study was conducted at an academic medical center. A total of 14 patients scheduled to undergo a right hip arthroscopy were enrolled and compared with a control group of 17 participants to account for a potential learning phenomenon. Patients drove in the simulator preoperatively to establish a baseline, and then drove again at 2, 4, 6, and 8 weeks postoperatively. The control group did not undergo any type of surgical procedure. The main independent variable was time from surgery. A modern driving simulator was used to measure initial reaction time (IRT), throttle release time (TRT), foot movement time (FMT), and brake travel time (BTT). The braking reaction time (BRT) was calculated as the sum of IRT + TRT + FMT, and the total braking time (TBT) was calculated as the sum of BRT + BTT. The experimental group showed no significant changes in BTT (P = 0.11, (Equation is included in full-text article.)= 0.04) nor TBT (P = 0.20, (Equation is included in full-text article.)= 0.03) over the duration of 8 weeks. Although the experimental group did exhibit significant improvements in IRT (P = 0.002), TRT (P < 0.0001), FMT (P < 0.0001), and BRT (P = 0.0002) between preoperative and 2 weeks postoperative driving sessions, there were no significant changes thereafter. The mean preoperative TBT and 2 weeks postoperative TBT for the experimental group were 3.07 seconds (SD = 0.50) and 2.97 seconds (SD = 0.57), respectively. No learning phenomenon was observed in the control group. This study's findings suggest that patients may return to driving 2 weeks postoperatively from a right-sided hip arthroscopy procedure.
Simultaneous measurement of friction and wear in hip simulators.
Haider, Hani; Weisenburger, Joel N; Garvin, Kevin L
2016-05-01
We propose and have evaluated a method to measure hip friction during wear testing on a popular multi-station hip simulator. A 6-degree-of-freedom load cell underneath the specimen sensed forces and torques during implant wear testing of simulated walking. This included internal-external and adduction-abduction rotations which are often neglected during friction testing on pendulum-type machines. Robust mathematical analysis and data processing provided friction estimates in three simultaneous orthogonal rotations, over extended multi-million cycle wear tests. We tested various bearing couples including metal-on-plastic, ceramic-on-plastic, and metal-on-metal material couples. In one test series, new and intentionally scratched CoCrMo 40-mm-diameter femoral heads were tested against conventional ultrahigh-molecular-weight polyethylene, highly cross-linked, and highly cross-linked with vitamin E versions. The scratching significantly increased friction and doubled the wear of all groups. Before scratching, friction levels for the aforementioned plastic groups were 0.056 ± 0.0060, 0.062 ± 0.0080, and 0.070 ± 0.0045, respectively, but after scratching increased to 0.088 ± 0.018, 0.076 ± 0.0066, and 0.082 ± 0.0049, respectively, all statistically significant increases (p = 0.00059, 0.00005, 0.0115, respectively). In another test series of 44-mm femoral head diameter hips, metal-on-plastic hips with conventional ultrahigh-molecular-weight polyethylene showed the lowest friction at 0.045 ± 0.0085, followed by highly cross-linked with 0.046 ± 0.0035 (not significantly different). In a ceramic-on-plastic design with conventional ultrahigh-molecular-weight polyethylene, higher friction 0.079 ± 0.0070 was measured likely due to that ceramic surface being rougher than usual. Metal-on-metal hips were compared without and with a TiN coating, resulting in 0.049 ± 0.014 and 0.097 ± 0.020 friction factors, respectively (statistically significant, p < 0.001), and the coating wore away on all coated hips eventually. Higher friction mostly correlated with higher wear or damage to femoral heads or implant coatings, except for the highly cross-linked wear resistant ultrahigh-molecular-weight polyethylene which had slightly higher friction, confirming the same finding in other independent studies. This type of friction measurements can help screen for clamping and elevated wear of metal-on-metal and resurfacing total hip replacements, surgical malpositioning, and abraded and otherwise damaged surfaces. © IMechE 2016.
Kubota, So; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Tezuka, Taro; Saito, Tomoyuki
2017-10-16
While cam resection is essential to achieve a good clinical result with respect to femoroacetabular impingement (FAI), it is unclear whether it should also be performed in cases of borderline developmental dysplasia of the hip (DDH) with a cam deformity. The aim of this study was to evaluate improvements in range of motion (ROM) in cases of cam-type FAI and borderline DDH after virtual osteochondroplasty using a computer impingement simulation. Thirty-eight symptomatic hips in 31 patients (11male and 20 female) diagnosed with cam-type FAI or borderline DDH were analyzed. There were divided into a cam-type FAI group (cam-FAI group: 15 hips), borderline DDH without cam group (DDH W/O cam group: 12 hips), and borderline DDH with cam group (DDH W/ cam group: 11 hips). The bony impingement point on the femoral head-neck junction at 90° flexion and maximum internal rotation of the hip joint was identified using ZedHip® software. Virtual osteochondroplasty of the impingement point was then performed in all cases. The maximum flexion angle and maximum internal rotation angle at 90° flexion were measured before and after virtual osteochondroplasty at two resection ranges (i.e., slight and sufficient). The mean improvement in the internal rotation angle in the DDH W/ cam group after slight resection was significantly greater than that in the DDH W/O cam group (P = 0.046). Furthermore, the mean improvement in the internal rotation angle in the DDH W/ cam and cam-FAI groups after sufficient resection was significantly greater than that in the DDH W/O cam group (DDH W/ cam vs DDH W/O cam: P = 0.002, cam-FAI vs DDH W/O cam: P = 0.043). Virtual osteochondroplasty resulted in a significant improvement in internal rotation angle in DDH W/ cam group but not in DDH W/O cam group. Thus, borderline DDH cases with cam deformity may be better to consider performing osteochondroplasty.
Tribological measurements on a Charnley-type artificial hip joint
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.
1983-01-01
A total hip simulator was used to determine the friction and wear properties of Charnley-type (316L stainless steel balls and sterile ultrahigh molecular weight polyethylene cups) hip prostheses. Three different sets of specimens were tested to 395,000, 101,500 and 233,000 walking cycles, respectively. All tests were run unlubricated, at ambient conditions (22 to 26 C, 30 to 50 percent relative humidity), at 30 walking cycles per minute, under a dynamic load simulating walking. Polyethylene cup wear rates ranged from 1.4 to 39 ten billions cu m which corresponds to dimensional losses of 4.0 to 11 microns per year. Although these wear rates are lower than those obtained from other hip simulators and from in vivo X-ray measurements, they are comparable when taking run-in and plastic deformation into account. Maximum tangential friction forces ranged from 93 to 129 N under variable load (267 to 3090 N range) and from 93 to 143 N under a static load of 3090 N. A portion of one test 250,000 walking cycles) run under dry air ( 1 percent relative humidity) yielded a wear rate almost 6 times greater than that obtained under wet air ( 70 percent relative humidity) conditions.
Activation of the hip adductor muscles varies during a simulated weight-bearing task.
Hides, Julie A; Beall, Paula; Franettovich Smith, Melinda M; Stanton, Warren; Miokovic, Tanja; Richardson, Carolyn
2016-01-01
To investigate the pattern of muscle activation of the individual hip adductor muscles using a standardised simulated unilateral weight-bearing task. A repeated measures design. Laboratory. 20 healthy individuals (11 females, 9 males) participated in the study. Age ranged from 20 to 25 years. Surface electromyography recordings from adductor magnus and adductor longus muscles were taken at levels representing 10-50% of body weight during a simulated weight-bearing task. Electromyography (EMG) data were normalised to maximal voluntary isometric contraction. The adductor magnus was recruited at significantly higher levels than the adductor longus muscle during a simulated weight-bearing task performed across 10-50% of body weight (p < 0.01). Adductor magnus and adductor longus muscles are recruited to different extents during a simulated weight-bearing task. This information should be considered when selecting exercises for management and prevention of groin strains. Closed chain exercises with weight-bearing through the lower limb are more likely to recruit the adductor magnus muscle over the adductor longus muscle. Copyright © 2015 Elsevier Ltd. All rights reserved.
Parchi, Paolo Domenico; Ferrari, Vincenzo; Piolanti, Nicola; Andreani, Lorenzo; Condino, Sara; Evangelisti, Gisberto; Lisanti, Michele
2013-09-01
Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.
Tong, Kuang; Zhang, Yuanzhi; Zhang, Sheng; Yu, Bin
2013-06-01
To provide an accurate method for osteotomy in the treatment of developmental dysplasia of the hip with steel osteotomy by three-dimensional reconstruction and Reverse Engineering technique. Between January 2011 and December 2012, 13 children with developmental dysplasia of the hip underwent steel osteotomy. 3D CT scan pelvic images were obtained and transferred via a DICOM network into a computer workstation to construct 3D models of the hip using Materialise Mimics 14.1 software in STL format. These models were imported into Imageware 12.0 software for steel osteotomy simulation until a stable hip was attained in the anatomical position for dislocation or subluxation of the hip in older children. The osteotomy navigational templates were designed according to the anatomical features after a stable hip was reconstructed. These navigational templates were manufactured using a rapid prototyping technique. The reconstruction hips in these children show good matching property and acetabulum cover. The computer-aided design of osteotomy template provides personalized and accurate solutions in the treatment of developmental dysplasia of the hip with steel osteotomy in older children.
Grammatopoulos, G; Pandit, H G; da Assunção, R; McLardy-Smith, P; De Smet, K A; Gill, H S; Murray, D W
2014-10-01
There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph. ©2014 The British Editorial Society of Bone & Joint Surgery.
NASA Astrophysics Data System (ADS)
Ananthanarayanan, A.; Ambashta, R. D.; Sudarsan, V.; Ajithkumar, T.; Sen, D.; Mazumder, S.; Wattal, P. K.
2017-04-01
Sodium zirconium phosphate (NZP) ceramics have been prepared using conventional sintering and hot isostatic pressing (HIP) routes. The structure of NZP ceramics, prepared using the HIP route, has been compared with conventionally sintered NZP using a combination of X-ray diffraction (XRD) and (31P and 23Na) nuclear magnetic resonance (NMR) spectroscopy techniques. It is observed that NZP with no waste loading is aggressive toward the steel HIP-can during hot isostatic compaction and significant fraction of cations from the steel enter the ceramic material. Waste loaded NZP samples (10 wt% simulated FBR waste) show significantly low can-interaction and primary NZP phase is evident in this material. Upon exposure of can-interacted and waste loaded NZP to boiling water and steam, 31P NMR does not detect any major modifications in the network structure. However, the 23Na NMR spectra indicate migration of Na+ ions from the surface and possible re-crystallization. This is corroborated by Small-Angle Neutron Scattering (SANS) data and Scanning Electron Microscopy (SEM) measurements carried out on these samples.
Majumder, Santanu; Roychowdhury, Amit; Pal, Subrata
2008-09-18
A major worldwide health problem is hip fracture due to sideways fall among the elderly population. The effects of sideways fall on the hip are required to be investigated thoroughly. The objectives of this study are to evaluate the responses to trochanteric soft tissue thickness (T) variations and hip impact velocity (V) variations during sideways fall based on a previously developed CT scan derived 3D non-linear and non-homogeneous finite element model of pelvis-femur-soft tissue complex with simplified biomechanical representation of the whole body. This study is also aimed at quantifying the effects [peak impact force (F(max)), time to F(max), acceleration and peak principal compressive strain (epsilon(max))] of these variations (T,V) on hip fracture. It was found that under constant impact energy, for 81% decrease in T (26-5mm), F(max) and epsilon(max) increased by 38% and 97%, respectively. Hence, decrease in T (as in slimmer persons) strongly correlated to risk for hip fracture (phi) and strain ratio (SR) by 0.972 and 0.988, respectively. Also under same T and body weight, for 75% decrease in V (4.79-1.2m/s), F(max) and epsilon(max) decreased by 70% and 86%, respectively. Hence, increase in V (as in taller persons) strongly correlated to phi and SR by 0.995 and 0.984, respectively. For both variations in T and V, inter-trochanteric fracture situations were well demonstrated by phi as well as by SR and strain contours, similar to clinically observed fractures. These quantifications would be helpful for effective design of person-specific hip protective devices.
2014-01-01
Background To validate physical activity estimates by the Sensewear Pro3 activity monitor compared with indirect calorimetry during simulated free living in patients diagnosed with osteoarthritis of the hip pre or post total hip arthroplasty. Methods Twenty patients diagnosed with hip osteoarthritis (10 pre- and 10 post total hip arthroplasty; 40% female; age: 63.3 ± 9.0; BMI: 23.7 ± 3.7). All patients completed a 2 hour protocol of simulated free living with 8 different typical physical activity types. Energy consumption (kcal/min) was estimated by the Sense Wear pro3 Armband activity monitor and validated against indirect calorimetry (criterion method) by means of a portable unit (Cosmed K4b2). Bias and variance was analyzed using functional ANOVA. Results Mean bias during all activities was 1.5 Kcal/min 95%CI [1.3; 1.8] corresponding to 72% (overestimation). Normal gait speed showed an overestimation of 2.8 Kcal/min, 95%CI [2.3; 3.3] (93%) while an underestimation of -1.1 Kcal/min, 95%CI [-1.8; -0.3] (-25%) was recorded during stair climb. Activities dominated by upper body movements showed large overestimation with 4.37 Kcal/min, 95%CI [3.8; 5.1] (170%) being recorded during gardening. Both bias and variance appeared to be dependent on activity type. Conclusion The activity monitor generally overestimated the energy consumption during common activities of low to medium intensity in the patient group. The size and direction of the bias was highly dependent on the activity type which indicates the activity monitor is of limited value in patients with hip osteoarthritis and that the results do not express the real energy expenditure. PMID:24552503
Planning acetabular fracture reduction using patient-specific multibody simulation of the hip
NASA Astrophysics Data System (ADS)
Oliveri, Hadrien; Boudissa, Mehdi; Tonetti, Jerome; Chabanas, Matthieu
2017-03-01
Acetabular fractures are a challenge in orthopedic surgery. Computer-aided solutions were proposed to segment bone fragments, simulate the fracture reduction or design the osteosynthesis fixation plates. This paper addresses the simulation part, which is usually carried out by freely moving bone fragments with six degrees of freedom to reproduce the pre-fracture state. Instead we propose a different paradigm, closer to actual surgeon's requirements: to simulate the surgical procedure itself rather than the desired result. A simple, patient-specific, biomechanical multibody model is proposed, integrating the main ligaments and muscles of the hip joint while accounting for contacts between bone fragments. Main surgical tools and actions can be simulated, such as clamps, Schanz screws or traction of the femur. Simulations are computed interactively, which enables clinicians to evaluate different strategies for an optimal surgical planning. Six retrospective cases were studied, with simple and complex fracture patterns. After interactively building the models from preoperative CT, gestures from the surgical reports were reproduced. Results of the simulations could then be compared with postoperative CT data. A qualitative study shows the model behavior is excellent and the simulated reductions fit the observed data. A more quantitative analysis is currently being completed. Two cases are particularly significant, for which the surgical reduction actually failed. Simulations show it was indeed not possible to reduce these fractures with the chosen approach. Had our simulator being used, a better planning may have avoided a second surgery to these patients.
Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W
2016-08-01
The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Faisal, Tanvir R; Luo, Yunhua
2017-10-03
Hip fracture of elderly people-suffering from osteoporosis-is a severe public health concern, which can be reduced by providing a prior assessment of hip fracture risk. Image-based finite element analysis (FEA) has been considered an effective computational tool to assess the hip fracture risk. Considering the femoral neck region is the weakest, fracture risk indicators (FRI) are evaluated for both single-legged stance and sideways fall configurations and are compared between left and right femurs of each subject. Quantitative Computed Tomography (QCT) scan datasets of thirty anonymous patients' left and right femora have been considered for the FE models, which have been simulated with an equal magnitude of load applied to the aforementioned configurations. The requirement of bilateral hip assessment in predicting the fracture risk has been explored in this study. Comparing the sideways fall and single-legged stance, the FRI varies by 64 to 74% at the superior aspects and by 14 to 19% at the inferior surfaces of both the femora. The results of this in vivo analysis clearly substantiate that the fracture is expected to initiate at the superior surface of femoral neck region if a patient falls from his/her standing height. The distributions of FRI between the femurs vary considerably, and the variability is significant at the superior aspects. The p value (= 0.02) obtained from paired sample t-Test yields p value ≤ 0.05, which shows the evidence of variability of the FRI distribution between left and right femurs. Moreover, the comparison of FRIs between the left and right femur of men and women shows that women are more susceptible to hip fracture than men. The results and statistical variation clearly signify a need for bilateral hip scanning in predicting hip fracture risk, which is clinically conducted, at present, based on one hip chosen randomly and may lead to inaccurate fracture prediction. This study, although preliminary, may play a crucial role in assessing the hip fractures of the geriatric population and thereby, reducing the cost of treatment by taking predictive measure.
Russell, Robert D; Huo, Michael H; Rodrigues, Danieli C; Kosmopoulos, Victor
2016-11-14
Stable femoral fixation during uncemented total hip arthroplasty is critical to allow for subsequent osseointegration of the prosthesis. Varying stem designs provide surgeons with multiple options to gain femoral fixation. The purpose of this study was to compare the initial fixation stability of cylindrical and tapered stem implants using two different underreaming techniques (press-fit conditions) for revision total hip arthroplasty (THA). A finite element femur model was created from three-dimensional computed tomography images simulating a trabecular bone defect commonly observed in revision THA. Two 18-mm generic femoral hip implants were modeled using the same geometry, differing only in that one had a cylindrical stem and the other had a 2 degree tapered stem. Surgery was simulated using a 0.05-mm and 0.01-mm press-fit and tested with a physiologically relevant loading protocol. Mean contact pressure was influenced more by the surgical technique than by the stem geometry. The 0.05-mm press-fit condition resulted in the highest contact pressures for both the cylindrical (27.35 MPa) and tapered (20.99 MPa) stems. Changing the press-fit to 0.01-mm greatly decreased the contact pressure by 79.8% and 78.5% for the cylindrical (5.53 MPa) and tapered (4.52 MPa) models, respectively. The cylindrical stem geometry consistently showed less relative micromotion at all the cross-sections sampled as compared to the tapered stem regardless of press-fit condition. This finite element analysis study demonstrates that tapered stem results in lower average contact pressure and greater micromotion at the implant-bone interface than a cylindrical stem geometry. More studies are needed to establish how these different stem geometries perform in such non-ideal conditions encountered in revision THA cases where less bone stock is available.
Towards Subject-Specific Strength Training Design through Predictive Use of Musculoskeletal Models.
Plüss, Michael; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio
2018-01-01
Lower extremity dysfunction is often associated with hip muscle strength deficiencies. Detailed knowledge of the muscle forces generated in the hip under specific external loading conditions enables specific structures to be trained. The aim of this study was to find the most effective movement type and loading direction to enable the training of specific parts of the hip muscles using a standing posture and a pulley system. In a novel approach to release the predictive power of musculoskeletal modelling techniques based on inverse dynamics, flexion/extension and ab-/adduction movements were virtually created. To demonstrate the effectiveness of this approach, three hip orientations and an external loading force that was systematically rotated around the body were simulated using a state-of-the art OpenSim model in order to establish ideal designs for training of the anterior and posterior parts of the M. gluteus medius (GM). The external force direction as well as the hip orientation greatly influenced the muscle forces in the different parts of the GM. No setting was found for simultaneous training of the anterior and posterior parts with a muscle force higher than 50% of the maximum. Importantly, this study has demonstrated the use of musculoskeletal models as an approach to predict muscle force variations for different strength and rehabilitation exercise variations.
Towards Subject-Specific Strength Training Design through Predictive Use of Musculoskeletal Models
Plüss, Michael; Schellenberg, Florian
2018-01-01
Lower extremity dysfunction is often associated with hip muscle strength deficiencies. Detailed knowledge of the muscle forces generated in the hip under specific external loading conditions enables specific structures to be trained. The aim of this study was to find the most effective movement type and loading direction to enable the training of specific parts of the hip muscles using a standing posture and a pulley system. In a novel approach to release the predictive power of musculoskeletal modelling techniques based on inverse dynamics, flexion/extension and ab-/adduction movements were virtually created. To demonstrate the effectiveness of this approach, three hip orientations and an external loading force that was systematically rotated around the body were simulated using a state-of-the art OpenSim model in order to establish ideal designs for training of the anterior and posterior parts of the M. gluteus medius (GM). The external force direction as well as the hip orientation greatly influenced the muscle forces in the different parts of the GM. No setting was found for simultaneous training of the anterior and posterior parts with a muscle force higher than 50% of the maximum. Importantly, this study has demonstrated the use of musculoskeletal models as an approach to predict muscle force variations for different strength and rehabilitation exercise variations. PMID:29796082
Yamamoto, Kengo; Masaoka, Toshinori; Manaka, Masakazu; Oonishi, Hironobu; Clarke, Ian; Shoji, Hiromu; Kawanabe, Keiichi; Imakiire, Atsuhiro
2004-04-01
We studied the micro-wear phenomena of unique, extensively cross-linked polyethylene cups (cross-linked with 1,000 kGy-irradiation) that had been used briefly in Japan. Two retrievals (at 15 years) came from the Japanese "SOM" hip system (implanted 1971-78). These were compared to a set of 0 kGy and 500-1,500 kGy cups run in our hip simulator. The polyethylene cups that had not been cross-linked had the greatest wear. The worn areas had a burnished appearance and were clearly separated from the unworn region by a distinct ridge-line. The worn areas had lost all machine tracks, showed a large amount of UHMWPE 'flow', and long PE fibrils. The associated surface rippling was degraded. These features were considered synonymous with severe polyethylene wear. In contrast, the worn areas in the very cross-linked cups had a visibly matte surface and no ridge-line. Micro-examination showed that the machine tracks were still present. Ripple formations were less obvious than in the cups that were not cross-linked, polyethylene surface fibrils were scarcer and all the fibrils were much smaller than in the cups that were not crosslinked. Our two retrieved cups and the simulator cups confirmed the greater wear-resistance of very cross-linked polyethylene. It should also be noted that the SOM cup design and processing were unique and differed greatly from that of modern polyethylene cups.
Artifact Reduction in X-Ray CT Images of Al-Steel-Perspex Specimens Mimicking a Hip Prosthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madhogarhia, Manish; Munshi, P.; Lukose, Sijo
2008-09-26
X-ray Computed Tomography (CT) is a relatively new technique developed in the late 1970's, which enables the nondestructive visualization of the internal structure of objects. Beam hardening caused by the polychromatic spectrum is an important problem in X-ray computed tomography (X-CT). It leads to various artifacts in reconstruction images and reduces image quality. In the present work we are considering the Artifact Reduction in Total Hip Prosthesis CT Scan which is a problem of medical imaging. We are trying to reduce the cupping artifact induced by beam hardening as well as metal artifact as they exist in the CT scanmore » of a human hip after the femur is replaced by a metal implant. The correction method for beam hardening used here is based on a previous work. Simulation study for the present problem includes a phantom consisting of mild steel, aluminium and perspex mimicking the photon attenuation properties of a hum hip cross section with metal implant.« less
ERIC Educational Resources Information Center
Montoye, Alexander H. K.; Conger, Scott A.; Connolly, Christopher P.; Imboden, Mary T.; Nelson, M. Benjamin; Bock, Josh M.; Kaminsky, Leonard A.
2017-01-01
This study compared accuracy of energy expenditure (EE) prediction models from accelerometer data collected in structured and simulated free-living settings. Twenty-four adults (mean age 45.8 years, 50% female) performed two sessions of 11 to 21 activities, wearing four ActiGraph GT9X Link activity monitors (right hip, ankle, both wrists) and a…
Friction measurement in a hip wear simulator.
Saikko, Vesa
2016-05-01
A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. © IMechE 2016.
Estimation of appropriate lubricating film thickness in ceramic-on-ceramic hip prostheses
NASA Astrophysics Data System (ADS)
Tauviqirrahman, M.; Muchammad, Bayuseno, A. P.; Ismail, R.; Saputra, E.; Jamari, J.
2016-04-01
Artificial hip prostheses, consisting of femoral head and acetabular cup are widely used and have affected the lives of many people.However, the primary issue associated with the long term performance of hip prostheses is loosening induced by excessive wear during daily activity. Therefore, an effective lubrication is necessary to significantly decrease the wear. To help understand the lubricating performance of such typical hip joint prostheses, in the present paper a hydrodynamic lubrication model based on Reynolds equationwas introduced. The material pairs of ceramic acetabular cup against ceramic femoral head was investegated.The main aim of this study is to investigate of the effect of loading on the formation of lubricating film thickness.The model of a ball-in-socket configuration was considered assuming that the cup was stationary while the ball was to rotate at a steady angular velocityvarying loads.Based on simulation result, it was found that to promote fluid film lubrication and prevent the contacting components leading to wear, the film thickness of lubricant should be determined carefully based on the load applied. This finding may have useful implication in predicting the failure of lubricating synovial fluid film and wear generation in hip prostheses.
Basso, Trude; Klaksvik, Jomar; Syversen, Unni; Foss, Olav A
2014-12-18
Fourth generation composite femurs (4GCFs, models #3406 and #3403) simulate femurs of males <80 years with good bone quality. Since most hip fractures occur in old women with fragile bones, concern is raised regarding the use of standard 4GCFs in biomechanical experiments. In this study the stability of hip fracture fixations in 4GCFs was compared to human cadaver femurs (HCFs) selected to represent patients with hip fractures. Ten 4GCFs (Sawbones, Pacific Research Laboratories, Inc., Vashon, WA, USA) were compared to 24 HCFs from seven females and five males >60 years. Proximal femur anthropometric measurements were noted. Strain gauge rosettes were attached and femurs were mounted in a hip simulator applying a combined subject-specific axial load and torque. Baseline measurements of resistance to deformation were recorded. Standardized femoral neck fractures were surgically stabilized before the constructs were subjected to 20,000 load-cycles. An optical motion tracking system measured relative movements. Median (95% CI) head fragment migration was 0.8mm (0.4 to 1.1) in the 4GCF group versus 2.2mm (1.5 to 4.6) in the cadaver group (p=0.001). This difference in fracture stability could not be explained by observed differences in femoral anthropometry or potential overloading of 4GCFs. 4GCFs failed with fracture-patterns different from those observed in cadavers. To conclude, standard 4GCFs provide unrealistically stable bone-implant constructs and fail with fractures not observed in cadavers. Until a validated osteopenic or osteoporotic composite femur model is provided, standard 4GCFs should only be used when representing the biomechanical properties of young healthy femurs. Copyright © 2014 Elsevier Ltd. All rights reserved.
The strengths and weaknesses of inverted pendulum models of human walking.
McGrath, Michael; Howard, David; Baker, Richard
2015-02-01
An investigation into the kinematic and kinetic predictions of two "inverted pendulum" (IP) models of gait was undertaken. The first model consisted of a single leg, with anthropometrically correct mass and moment of inertia, and a point mass at the hip representing the rest of the body. A second model incorporating the physiological extension of a head-arms-trunk (HAT) segment, held upright by an actuated hip moment, was developed for comparison. Simulations were performed, using both models, and quantitatively compared with empirical gait data. There was little difference between the two models' predictions of kinematics and ground reaction force (GRF). The models agreed well with empirical data through mid-stance (20-40% of the gait cycle) suggesting that IP models adequately simulate this phase (mean error less than one standard deviation). IP models are not cyclic, however, and cannot adequately simulate double support and step-to-step transition. This is because the forces under both legs augment each other during double support to increase the vertical GRF. The incorporation of an actuated hip joint was the most novel change and added a new dimension to the classic IP model. The hip moment curve produced was similar to those measured during experimental walking trials. As a result, it was interpreted that the primary role of the hip musculature in stance is to keep the HAT upright. Careful consideration of the differences between the models throws light on what the different terms within the GRF equation truly represent. Copyright © 2014 Elsevier B.V. All rights reserved.
Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.
Santavirta, Seppo
2003-12-01
Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.
Van Susante, Job L C; Verdonschot, Nico; Bom, L Paul A; Tomaszewski, Pawel; Campbell, Pat; Ebramzadeh, Edward; Schreurs, B Wim
2018-01-01
Background and purpose Hip resurfacing (HR) is a treatment option promoted for hip arthritis in young and active patients. However, adverse reactions to metal are a concern and the search for non-metallic bearing options proceeds. We present the first clinical study performed in patients using a newly developed hydrophilic polymer-on-polymer hip resurfacing device. Patients and methods After performing extensive hip simulator tests, biocompatibility testing and animal tests (ISO 14242-1,3; 10993-3,4,5,10,11), approval was obtained from the IRB committee to enroll 15 patients in the first clinical study in humans using this experimental polymer-on-polymer hip resurfacing device. All surgeries were done by 2 experienced hip resurfacing surgeons. Clinical scores and standard radiographs as well as routine MRIs were obtained at regular intervals. Results The surgical technique proved feasible with successful implantation of the new device using PMMA cement fixation on both sides without complications. Postoperative imaging revealed a well-positioned and well-fixed polymer resurfacing hip arthroplasty in all 4 initial cases. All 4 patients were free of pain and had good function for the first 2 months. However, in all 4 cases early cup loosening occurred between 8 and 11 weeks after surgery, necessitating immediate closure of the study. All 4 patients had a reoperation and were revised to a conventional THA. Retrieval analyses confirmed early cup loosening at the implant–cement interface in all 4 cases. The femoral components remained well attached to the cement. The periprosthetic tissues showed only small amounts of polymeric wear debris and there was only a very mild inflammatory reaction to this. Interpretation Early cup loosening mandated a premature arrest of this study. After additional laboratory testing this failure mode was found to be the result of a small, yet measurable contraction in the cup size after exposing these implants to biological fluid divalent ion fluctuations in vivo. Currently used preclinical tests had failed to detect this failure mechanism. Modification of the polymer is essential to overcome these problems and before the potential of a polymer-on-polymer resurfacing arthroplasty may be further evaluated in patients. PMID:28931340
Van Susante, Job L C; Verdonschot, Nico; Bom, L Paul A; Tomaszewski, Pawel; Campbell, Pat; Ebramzadeh, Edward; Schreurs, B Wim
2018-02-01
Background and purpose - Hip resurfacing (HR) is a treatment option promoted for hip arthritis in young and active patients. However, adverse reactions to metal are a concern and the search for non-metallic bearing options proceeds. We present the first clinical study performed in patients using a newly developed hydrophilic polymer-on-polymer hip resurfacing device. Patients and methods - After performing extensive hip simulator tests, biocompatibility testing and animal tests (ISO 14242-1,3; 10993-3,4,5,10,11), approval was obtained from the IRB committee to enroll 15 patients in the first clinical study in humans using this experimental polymer-on-polymer hip resurfacing device. All surgeries were done by 2 experienced hip resurfacing surgeons. Clinical scores and standard radiographs as well as routine MRIs were obtained at regular intervals. Results - The surgical technique proved feasible with successful implantation of the new device using PMMA cement fixation on both sides without complications. Postoperative imaging revealed a well-positioned and well-fixed polymer resurfacing hip arthroplasty in all 4 initial cases. All 4 patients were free of pain and had good function for the first 2 months. However, in all 4 cases early cup loosening occurred between 8 and 11 weeks after surgery, necessitating immediate closure of the study. All 4 patients had a reoperation and were revised to a conventional THA. Retrieval analyses confirmed early cup loosening at the implant-cement interface in all 4 cases. The femoral components remained well attached to the cement. The periprosthetic tissues showed only small amounts of polymeric wear debris and there was only a very mild inflammatory reaction to this. Interpretation - Early cup loosening mandated a premature arrest of this study. After additional laboratory testing this failure mode was found to be the result of a small, yet measurable contraction in the cup size after exposing these implants to biological fluid divalent ion fluctuations in vivo. Currently used preclinical tests had failed to detect this failure mechanism. Modification of the polymer is essential to overcome these problems and before the potential of a polymer-on-polymer resurfacing arthroplasty may be further evaluated in patients.
A New Sensor for Measurement of Dynamic Contact Stress in the Hip
Rudert, M. J.; Ellis, B. J.; Henak, C. R.; Stroud, N. J.; Pederson, D. R.; Weiss, J. A.; Brown, T. D.
2014-01-01
Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shoulder, ankle, wrist, and spinal facet joints. Until now, however, no such sensor had been available for the human hip joint due to difficulties posed by the deep, bi-curvilinear geometry of the acetabulum. We report here the design and development of a novel sensor capable of measuring dynamic contact stress in human cadaveric hip joints (maximum contact stress of 20 MPa and maximum sampling rate 100 readings/s). Particular emphasis is placed on issues concerning calibration, and on the effect of joint curvature on the sensor's performance. The active pressure-sensing regions of the sensors have the shape of a segment of an annulus with a 150-deg circumferential span, and employ a polar/circumferential “ring-and-spoke” sensel grid layout. There are two sensor sizes, having outside radii of 44 and 48 mm, respectively. The new design was evaluated in human cadaver hip joints using two methods. The stress magnitudes and spatial distribution measured by the sensor were compared to contact stresses measured by pressure sensitive film during static loading conditions that simulated heel strike during walking and stair climbing. Additionally, the forces obtained by spatial integration of the sensor contact stresses were compared to the forces measured by load cells during the static simulations and for loading applied by a dynamic hip simulator. Stress magnitudes and spatial distribution patterns obtained from the sensor versus from pressure sensitive film exhibited good agreement. The joint forces obtained during both static and dynamic loading were within ±10% and ±26%, respectively, of the forces measured by the load cells. These results provide confidence in the measurements obtained by the sensor. The new sensor's real-time output and dynamic measurement capabilities hold significant advantages over static measurements from pressure sensitive film. PMID:24763632
A new sensor for measurement of dynamic contact stress in the hip.
Rudert, M J; Ellis, B J; Henak, C R; Stroud, N J; Pederson, D R; Weiss, J A; Brown, T D
2014-03-01
Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shoulder, ankle, wrist, and spinal facet joints. Until now, however, no such sensor had been available for the human hip joint due to difficulties posed by the deep, bi-curvilinear geometry of the acetabulum. We report here the design and development of a novel sensor capable of measuring dynamic contact stress in human cadaveric hip joints (maximum contact stress of 20 MPa and maximum sampling rate 100 readings/s). Particular emphasis is placed on issues concerning calibration, and on the effect of joint curvature on the sensor's performance. The active pressure-sensing regions of the sensors have the shape of a segment of an annulus with a 150-deg circumferential span, and employ a polar/circumferential "ring-and-spoke" sensel grid layout. There are two sensor sizes, having outside radii of 44 and 48 mm, respectively. The new design was evaluated in human cadaver hip joints using two methods. The stress magnitudes and spatial distribution measured by the sensor were compared to contact stresses measured by pressure sensitive film during static loading conditions that simulated heel strike during walking and stair climbing. Additionally, the forces obtained by spatial integration of the sensor contact stresses were compared to the forces measured by load cells during the static simulations and for loading applied by a dynamic hip simulator. Stress magnitudes and spatial distribution patterns obtained from the sensor versus from pressure sensitive film exhibited good agreement. The joint forces obtained during both static and dynamic loading were within ±10% and ±26%, respectively, of the forces measured by the load cells. These results provide confidence in the measurements obtained by the sensor. The new sensor's real-time output and dynamic measurement capabilities hold significant advantages over static measurements from pressure sensitive film.
Hua, Xijin; Wang, Ling; Al-Hajjar, Mazen; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John
2014-07-01
Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid. © IMechE 2014.
The influence of muscles on knee flexion during the swing phase of gait.
Piazza, S J; Delp, S L
1996-06-01
Although the movement of the leg during swing phase is often compared to the unforced motion of a compound pendulum, the muscles of the leg are active during swing and presumably influence its motion. To examine the roles of muscles in determining swing phase knee flexion, we developed a muscle-actuated forward dynamic simulation of the swing phase of normal gait. Joint angles and angular velocities at toe-off were derived from experimental measurements, as were pelvis motions and muscle excitations. Joint angles and joint moments resulting from the simulation corresponded to experimental measurements made during normal gait. Muscular joint moments and initial joint angular velocities were altered to determine the effects of each upon peak knee flexion in swing phase. As expected, the simulation demonstrated that either increasing knee extension moment or decreasing toe-off knee flexion velocity decreased peak knee flexion. Decreasing hip flexion moment or increasing toe-off hip flexion velocity also caused substantial decreases in peak knee flexion. The rectus femoris muscle played an important role in regulating knee flexion; removal of the rectus femoris actuator from the model resulted in hyperflexion of the knee, whereas an increase in the excitation input to the rectus femoris actuator reduced knee flexion. These findings confirm that reduced knee flexion during the swing phase (stiff-knee gait) may be caused by overactivity of the rectus femoris. The simulations also suggest that weakened hip flexors and stance phase factors that determine the angular velocities of the knee and hip at toe-off may be responsible for decreased knee flexion during swing phase.
The effect of dynamic femoroacetabular impingement on pubic symphysis motion: a cadaveric study.
Birmingham, Patrick M; Kelly, Bryan T; Jacobs, Robert; McGrady, Linda; Wang, Mei
2012-05-01
A link between femoroacetabular impingement and athletic pubalgia has been reported clinically. One proposed origin of athletic pubalgia is secondary to repetitive loading of the pubic symphysis, leading to instability and parasymphyseal tendon and ligament injury. Hypothesis/ The purpose of this study was to investigate the effect of simulated femoral-based femoroacetabular impingement on rotational motion at the pubic symphysis. The authors hypothesize that the presence of a cam lesion leads to increased relative symphyseal motion. Controlled laboratory study. Twelve hips from 6 fresh-frozen human cadaveric pelvises were used to simulate cam-type femoroacetabular impingement. The hips were held in a custom jig and maximally internally rotated at 90° of flexion and neutral adduction. Three-dimensional motion of the pubic symphysis was measured by a motion-tracking system for 2 states: native and simulated cam. Load-displacement plots were generated between the internal rotational torque applied to the hip and the responding motion in 3 anatomic planes of the pubic symphysis. As the hip was internally rotated, the motion at the pubic symphysis increased proportionally with the degrees of the rotation as well as the applied torque measured at the distal femur for both states. The primary rotation of the symphysis was in the transverse plane and on average accounted for more than 60% of the total rotation. This primary motion caused the anterior aspect of the symphyseal joint to open or widen, whereas the posterior aspect narrowed. At the torque level of 18.0 N·m, the mean transverse rotation in degrees was 0.89° ± 0.35° for the native state and 1.20° ± 0.41° for cam state. The difference between cam and the native groups was statistically significant (P < .03). Dynamic femoroacetabular impingement as caused by the presence of a cam lesion causes increased rotational motion at the pubic symphysis. Repetitive loading of the symphysis by cam impingement is thought to lead to increased symphyseal motion, which is one possible precursor to athletic pubalgia.
Lin, Z L; Li, P F; Pang, Z H; Zheng, X H; Huang, F; Xu, H H; Li, Q L
2015-11-01
Hip fracture is a kind of osteoporotic fractures in elderly patients. Its important monitoring indicator is to measure bone mineral density (BMD) using DXA. The stress characteristics and material distribution in different parts of the bones can be well simulated by three-dimensional finite element analysis. Our previous studies have demonstrated a linear positive correlation between clinical BMD and the density of three-dimensional finite element model of the femur. However, the correlation between the density variation between intertrochanteric region and collum femoris region of the model and the fracture site has not been studied yet. The present study intends to investigate whether the regional difference in the density of three-dimensional finite element model of the femur can be used to predict hip fracture site in elderly females. The CT data of both hip joints were collected from 16 cases of elderly female patients with hip fractures. Mimics 15.01 software was used to reconstruct the model of proximal femur on the healthy side. Ten kinds of material properties were assigned. In Abaqus 6.12 software, the collum femoris region and intertrochanteric region were, respectively, drawn for calculating the corresponding regional density of the model, followed by prediction of hip fracture site and final comparison with factual fracture site. The intertrochanteric region/collum femoris region density was [(1.20 ± 0.02) × 10(6)] on the fracture site and [(1.22 ± 0.03) × 10(6)] on the non-fracture site, and the difference was statistically significant (P = 0.03). Among 16 established models of proximal femur on the healthy side, 14 models were consistent with the actual fracture sites, one model was inconsistent, and one model was unpredictable, with the coincidence rate of 87.5 %. The intertrochanteric region or collum femoris region with lower BMD is more prone to hip fracture of the type on the corresponding site.
NASA Astrophysics Data System (ADS)
Atmani, O.; Abbès, B.; Abbès, F.; Li, Y. M.; Batkam, S.
2018-05-01
Thermoforming of high impact polystyrene sheets (HIPS) requires technical knowledge on material behavior, mold type, mold material, and process variables. Accurate thermoforming simulations are needed in the optimization process. Determining the behavior of the material under thermoforming conditions is one of the key parameters for an accurate simulation. The aim of this work is to identify the thermomechanical behavior of HIPS in the thermoforming conditions. HIPS behavior is highly dependent on temperature and strain rate. In order to reproduce the behavior of such material, a thermo-elasto-viscoplastic constitutive law was implement in the finite element code ABAQUS. The proposed model parameters are considered as thermo-dependent. The strain-dependence effect is introduced using Prony series. Tensile tests were carried out at different temperatures and strain rates. The material parameters were then identified using a NSGA-II algorithm. To validate the rheological model, experimental blowing tests were carried out on a thermoforming pilot machine. To compare the numerical results with the experimental ones the thickness distribution and the bubble shape were investigated.
Gallagher, Kaitlin M; Callaghan, Jack P
2016-09-01
While alternating standing position on a sloped surface has proven successful at reducing low back pain during standing, the purpose of this study was to evaluate standing solely on a declining surface to isolate the influence of the postural change. Seventeen participants performed two 75-min prolonged standing occupational simulations- level ground and declining surface. Fifty-three percent of participants (9/17) were categorized as pain developers during the level ground standing condition. For these same pain developers, their average maximum pain scores were 58% lower during sloped standing. All participants showed greater hip flexion, trunk-to-thigh angle flexion, and posterior translation of the trunk center of gravity when standing on the sloped surface. These postural changes could cause the muscles crossing the hip posteriorly to increase passive stiffness and assist with stabilizing the pelvis. This study stresses the importance of hip kinematics, not just lumbar spine posture, in reducing prolonged standing induced low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Finite element analysis on a medical implant.
Semenescu, Augustin; Radu-Ioniță, Florentina; Mateș, Ileana Mariana; Bădică, Petre; Batalu, Nicolae Dan; Negoita, Olivia Doina; Purcarea, Victor Lorin
2016-01-01
Several studies have shown a tight connection between several ocular pathologies and an increased risk of hip fractures due to falling, especially among elderly patients. The total replacement of the hip joint is a major surgical intervention that aims to restore the function of the affected hip by various factors, such as arthritis, injures, and others. A corkscrew-like femoral stem was designed in order to preserve the bone stock and to prevent the occurrence of iatrogenic fractures during the hammering of the implant. In this paper, the finite element analysis for the proposed design was applied, considering different loads and three types of materials. A finite element analysis is a powerful tool to simulate, optimize, design, and select suitable materials for new medical implants. The results showed that the best scenario was for Ti6Al4V alloy, although Ti and 316L stainless steel had a reasonable high safety factor.
Tarlochan, Faris; Mehboob, Hassan; Mehboob, Ali; Chang, Seung-Hwan
2018-06-01
Cementless hip prostheses with porous outer coating are commonly used to repair the proximally damaged femurs. It has been demonstrated that stability of prosthesis is also highly dependent on the bone ingrowth into the porous texture. Bone ingrowth is influenced by the mechanical environment produced in the callus. In this study, bone ingrowth into the porous structure was predicted by using a mechano-regulatory model. Homogenously distributed pores (200 and 800 [Formula: see text]m in diameter) and functionally graded pores along the length of the prosthesis were introduced as a porous coating. Bone ingrowth was simulated using 25 and 12 [Formula: see text]m micromovements. Load control simulations were carried out instead of traditionally used displacement control. Spatial and temporal distributions of tissues were predicted in all cases. Functionally graded pore decreasing models gave the most homogenous bone distribution, the highest bone ingrowth (98%) with highest average Young's modulus of all tissue phenotypes approximately 4.1 GPa. Besides this, the volume of the initial callus increased to 8.33% in functionally graded pores as compared to the 200 [Formula: see text]m pore size models which increased the bone volume. These findings indicate that functionally graded porous surface promote bone ingrowth efficiently which can be considered to design of surface texture of hip prosthesis.
The characterisation of next generation ceramic bearings for orthopaedic hip applications
NASA Astrophysics Data System (ADS)
Insley, Gerard M.
Two zirconia toughened alumina ceramic materials were characterised for application as bearing surfaces for hip joint arthroplasty. Both ceramics were supplied by orthopaedic ceramic suppliers in the form of flat discs, flexural strength bars and finished ball heads and cups. Analysis techniques involved standard and novel test methods in order to gauge the suitability of the ZTA for this application. These included mechanical strength testing, phase composition analysis by x-ray diffraction, accelerated and real time stability testing, friction testing and hip simulator testing under standard and nonstandard conditions. Alumina was used as a control in all testing. The results show the ZTA materials to be 50 to 75% stronger and up to 25% tougher than the alumina. Both materials differ in terms of their processing, microstructure and crystalline phase composition, however both showed no tetragonal to monoclinic degradation after both accelerated and real time ageing. The friction and wear tests show the ZTA to be performing as well as the alumina in normal test conditions. However, when microseparation is introduced into the hip simulator testing the ZTA ceramics wear significantly less than the alumina. Clinical analysis of a series of explanted heads showed that microseparation definitely occurs in the clinical situation with wear scars observed in eleven out of sixteen components. Zirconia toughened alumina is suitable as a fourth generation bearing surface for hip joint arthroplasty.
Changes in Gait with Anteriorly Added Mass: A Pregnancy Simulation Study
Ogamba, Maureen I.; Loverro, Kari L.; Laudicina, Natalie M.; Gill, Simone V.; Lewis, Cara L.
2016-01-01
During pregnancy, the female body experiences structural changes, such as weight gain. As pregnancy advances, most of the additional mass is concentrated anteriorly on the lower trunk. The purpose of this study is to analyze kinematic and kinetic changes when load is added anteriorly to the trunk, simulating a physical change experienced during pregnancy. Twenty healthy females walked on a treadmill while wearing a custom made pseudo-pregnancy sac (1 kg) under three load conditions: sac only, 10 pound condition (4.535 kg added anteriorly), and 20 pound condition (9.07 kg added anteriorly), used to simulate pregnancy, in the second trimester and at full term pregnancy, respectively. The increase in anterior mass resulted in kinematic changes at the knee, hip, pelvis, and trunk in the sagittal and frontal planes. Additionally, ankle, knee, and hip joint moments normalized to baseline mass increased with increased load; however, these moments decreased when normalized to total mass. These kinematic and kinetic changes may suggest that women modify gait biomechanics to reduce the effect of added load. Furthermore, the increase in joint moments increases stress on the musculoskeletal system and may contribute to musculoskeletal pain. PMID:26958743
Association of hip pain with radiographic evidence of hip osteoarthritis: diagnostic test study
Nevitt, Michael C; Niu, Jingbo; Clancy, Mary M; Lane, Nancy E; Link, Thomas M; Vlad, Steven; Tolstykh, Irina; Jungmann, Pia M.; Felson, David T; Guermazi, Ali
2015-01-01
Study question Is there concordance between hip pain and radiographic hip osteoarthritis? Methods In this diagnostic test study, pelvic radiographs were assessed for hip osteoarthritis in two cohorts: the Framingham Osteoarthritis Study (community of Framingham, Massachusetts) and the Osteoarthritis Initiative (a multicenter longitudinal cohort study of osteoarthritis in the United States). Using visual representation of the hip joint, participants reported whether they had hip pain on most days and the location of the pain: anterior, groin, lateral, buttocks, or low back. In the Framingham study, participants with hip pain were also examined for hip pain with internal rotation. The authors analysed the agreement between radiographic hip osteoarthritis and hip pain, and for those with hip pain suggestive of hip osteoarthritis they calculated the sensitivity, specificity, positive predictive value, and negative predictive value of radiographs as the diagnostic test. Study answer and limitations In the Framingham study (n=946), only 15.6% of hips in patients with frequent hip pain showed radiographic evidence of hip osteoarthritis, and 20.7% of hips with radiographic hip osteoarthritis were frequently painful. The sensitivity of radiographic hip osteoarthritis for hip pain localised to the groin was 36.7%, specificity 90.5%, positive predictive value 6.0%, and negative predictive value 98.9%. Results did not differ much for hip pain at other locations or for painful internal rotation. In the Osteoarthritis Initiative study (n=4366), only 9.1% of hips in patients with frequent pain showed radiographic hip osteoarthritis, and 23.8% of hips with radiographic hip osteoarthritis were frequently painful. The sensitivity of definite radiographic hip osteoarthritis for hip pain localised to the groin was 16.5%, specificity 94.0%, positive predictive value 7.1%, and negative predictive value 97.6%. Results also did not differ much for hip pain at other locations. What this study adds Hip pain was not present in many hips with radiographic osteoarthritis, and many hips with pain did not show radiographic hip osteoarthritis. Most older participants with a high suspicion for clinical hip osteoarthritis (groin or anterior pain and/or painful internal rotation) did not have radiographic hip osteoarthritis, suggesting that in many cases, hip osteoarthritis might be missed if diagnosticians relied solely on hip radiographs. Funding, competing interests, data sharing See the full paper on thebmj.com for funding. The authors have no competing interests. Additional data are available from bevochan@bu.edu. PMID:26631296
Affatato, Saverio; Zanini, Filippo; Carmignato, Simone
2017-01-01
Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations. PMID:28772616
A rapid prototyping model for biomechanical evaluation of pelvic osteotomies.
Pressel, Thomas; Max, Stefan; Pfeifer, Roman; Ostermeier, Sven; Windhagen, Henning; Hurschler, Christof
2008-04-01
The biomechanical consequences of Salter pelvic osteotomy are difficult to assess due to the complex three-dimensional anatomy of the pelvis. Therefore, models of the dysplastic pelvis are required to allow realistic biomechanical simulation of possible outcomes. A polyamide reversed-engineering model of the left hemipelvis and proximal femur was produced from a computed tomography dataset of an 8-year-old child with severe dysplasia of both hips using selective laser sintering. Hip joint forces before and after Salter osteotomy of the hip were measured using an experimental setup in which an industrial robot was exerting hip joint forces and moments representing one-legged stance. Hip extensor and abductor actuator forces were measured which counterbalanced the joint moments. The preoperative hip joint resultant force was 583 N (270% body weight), while after the operation a mean force of 266 N (120% body weight) was measured. The resulting bony model was geometrically accurate, while apparent joint incongruencies were due to the neglected cartilaginous structures in the model. The preoperative joint resultant force was within the limits reported in the literature. The results suggest that Salter innominate osteotomy not only increases joint contact area but also reduces the hip joint force.
Muscle function may depend on model selection in forward simulation of normal walking
Xiao, Ming; Higginson, Jill S.
2008-01-01
The purpose of this study was to quantify how the predicted muscle function would change in a muscle-driven forward simulation of normal walking when changing the number of degrees of freedom in the model. Muscle function was described by individual muscle contributions to the vertical acceleration of the center of mass (COM). We built a two-dimensional (2D) sagittal plane model and a three-dimensional (3D) model in OpenSim and used both models to reproduce the same normal walking data. Perturbation analysis was applied to deduce muscle function in each model. Muscle excitations and contributions to COM support were compared between the 2D and 3D models. We found that the 2D model was able to reproduce similar joint kinematics and kinetics patterns as the 3D model. Individual muscle excitations were different for most of the hip muscles but ankle and knee muscles were able to attain similar excitations. Total induced vertical COM acceleration by muscles and gravity was the same for both models. However, individual muscle contributions to COM support varied, especially for hip muscles. Although there is currently no standard way to validate muscle function predictions, a 3D model seems to be more appropriate for estimating individual hip muscle function. PMID:18804767
Modelling Accident Tolerant Fuel Concepts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hales, Jason Dean; Gamble, Kyle Allan Lawrence
2016-05-01
The catastrophic events that occurred at the Fukushima-Daiichi nuclear power plant in 2011 have led to widespread interest in research of alternative fuels and claddings that are proposed to be accident tolerant. The United States Department of Energy (DOE) through its Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has funded an Accident Tolerant Fuel (ATF) High Impact Problem (HIP). The ATF HIP is a three-year project to perform research on two accident tolerant concepts. The final outcome of the ATF HIP will be an in-depth report to the DOE Advanced Fuels Campaign (AFC) giving a recommendation on whether eithermore » of the two concepts should be included in their lead test assembly scheduled for placement into a commercial reactor in 2022. The two ATF concepts under investigation in the HIP are uranium silicide fuel and iron-chromium-aluminum (FeCrAl) alloy cladding. Utilizing the expertise of three national laboratory participants (Idaho National Laboratory, Los Alamos National Laboratory, and Argonne National Laboratory), a comprehensive multiscale approach to modeling is being used that includes atomistic modeling, molecular dynamics, rate theory, phase-field, and fuel performance simulations. Model development and fuel performance analysis are critical since a full suite of experimental studies will not be complete before AFC must prioritize concepts for focused development. In this paper, we present simulations of the two proposed accident tolerance fuel systems: U3Si2 fuel with Zircaloy-4 cladding, and UO2 fuel with FeCrAl cladding. Sensitivity analyses are completed using Sandia National Laboratories’ Dakota software to determine which input parameters (e.g., fuel specific heat) have the greatest influence on the output metrics of interest (e.g., fuel centerline temperature). We also outline the multiscale modelling approach being employed. Considerable additional work is required prior to preparing the recommendation report for the Advanced Fuels Campaign.« less
Effect of HIP temperature on microstructure and low cycle fatigue strength of CuCrZr alloy
NASA Astrophysics Data System (ADS)
Nishi, Hiroshi; Enoeda, Mikio
2011-10-01
In order to investigate the effect of the HIP cycle temperatures on the metallurgic degradation and the mechanical properties of CuCrZr alloy, assessments of the microstructure, tensile test, Charpy impact test and low cycle fatigue test are performed for various heat treated CuCrZr alloys, which were solution-annealed followed by water-quenched and aged state of CuCrZr with simulated HIP cycle at temperatures of 980 and 1045 °C. Grain growth occurred on 1045 °C HIP CuCrZr, though slightly on 980 °C HIP CuCrZr. Metallurgic degradation such as voids was not found by optical and SEM observations. There were coarse precipitates in all the CuCrZr and the precipitates did not easily dissolve at 980 °C. The low cycle fatigue strength of 1045 °C HIP CuCrZr was lower than that of other CuCrZr because of the metallurgic degradation caused by the heat cycle, while that of other CuCrZr was corresponding to the best fit curve of ITER MPH.
High-Tech Hip Implant for Wireless Temperature Measurements In Vivo
Bergmann, Georg; Graichen, Friedmar; Dymke, Jörn; Rohlmann, Antonius; Duda, Georg N.; Damm, Philipp
2012-01-01
When walking long distances, hip prostheses heat up due to friction. The influence of articulating materials and lubricating properties of synovia on the final temperatures, as well as any potential biological consequences, are unknown. Such knowledge is essential for optimizing implant materials, identifying patients who are possibly at risk of implant loosening, and proving the concepts of current joint simulators. An instrumented hip implant with telemetric data transfer was developed to measure the implant temperatures in vivo. A clinical study with 100 patients is planned to measure the implant temperatures for different combinations of head and cup materials during walking. This study will answer the question of whether patients with synovia with poor lubricating properties may be at risk for thermally induced bone necrosis and subsequent implant failure. The study will also deliver the different friction properties of various implant materials and prove the significance of wear simulator tests. A clinically successful titanium hip endoprosthesis was modified to house the electronics inside its hollow neck. The electronics are powered by an external induction coil fixed around the joint. A temperature sensor inside the implant triggers a timer circuit, which produces an inductive pulse train with temperature-dependent intervals. This signal is detected by a giant magnetoresistive sensor fixed near the external energy coil. The implant temperature is measured with an accuracy of 0.1°C in a range between 20°C and 58°C and at a sampling rate of 2–10 Hz. This rate could be considerably increased for measuring other data, such as implant strain or vibration. The employed technique of transmitting data from inside of a closed titanium implant by low frequency magnetic pulses eliminates the need to use an electrical feedthrough and an antenna outside of the implant. It enables the design of mechanically safe and simple instrumented implants. PMID:22927973
The design and development of a triaxial wear-testing joint simulator.
Green, A S; O'Connell, M K; Lyons, A S; James, S P
1999-01-01
Most of the existing wear testers created to wear test total hip replacements, specifically the acetabular component, are designed to exert only an axial force and provide rotation in a close approximation of the actual femoral movement. The Rocky Mountain Joint Simulator was designed to exert three orthogonal forces and provide rotations about the X-, Y- and Z-axes to more closely simulate the physiological forces and motions found in the human gait cycle. The RMJS was also designed with adaptability for other joints, such as knees or canine hips, through the use of hydraulics and a computer-programmable control system. Such adaptability and functionality allows the researcher to more closely model a gait cycle, thereby obtaining wear patterns that resemble those found in retrieved implants more closely than existing simulators. Research is ongoing into the tuning and evaluation of the machine and preliminary acetabular component wear test results will be presented at the conference.
Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin
2012-01-01
Background Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Methods Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. Results The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78±8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65±0.29 mm3/MC and 0.89±0.04 mm3/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. Conclusions This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. Clinical Relevance This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care. PMID:23144694
Liu, Feng; Chen, Zhefeng; Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin
2012-01-01
Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3)/MC and 0.89 ± 0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.
Monte Carlo calculations of the impact of a hip prosthesis on the dose distribution
NASA Astrophysics Data System (ADS)
Buffard, Edwige; Gschwind, Régine; Makovicka, Libor; David, Céline
2006-09-01
Because of the ageing of the population, an increasing number of patients with hip prostheses are undergoing pelvic irradiation. Treatment planning systems (TPS) currently available are not always able to accurately predict the dose distribution around such implants. In fact, only Monte Carlo simulation has the ability to precisely calculate the impact of a hip prosthesis during radiotherapeutic treatment. Monte Carlo phantoms were developed to evaluate the dose perturbations during pelvic irradiation. A first model, constructed with the DOSXYZnrc usercode, was elaborated to determine the dose increase at the tissue-metal interface as well as the impact of the material coating the prosthesis. Next, CT-based phantoms were prepared, using the usercode CTCreate, to estimate the influence of the geometry and the composition of such implants on the beam attenuation. Thanks to a program that we developed, the study was carried out with CT-based phantoms containing a hip prosthesis without metal artefacts. Therefore, anthropomorphic phantoms allowed better definition of both patient anatomy and the hip prosthesis in order to better reproduce the clinical conditions of pelvic irradiation. The Monte Carlo results revealed the impact of certain coatings such as PMMA on dose enhancement at the tissue-metal interface. Monte Carlo calculations in CT-based phantoms highlighted the marked influence of the implant's composition, its geometry as well as its position within the beam on dose distribution.
Tribological characterisation of UHMWPE used in dual mobility total hip prosthesis
NASA Astrophysics Data System (ADS)
Essefi, I.; Hakkouna, H.; Ouenzerfi, G.; Mollon, G.; Hamza, S.; Renault, E.; Berthier, Y.; Trunfio-Sfarghiu, A.-M.
2016-08-01
Total hip arthroplasty represents an effective solution for bone and joint diseases. Nevertheless, the hip prosthesis has a limited lifetime, in the average around fifteen years. Their improvement, especially their dual mobility is the objective of this study. Therefore, our strategy is focused on improving the material by comparing three types of polyethylene to determine the best one from a friction mechanism and wear rate minimization standpoint. A dual mobility hip prosthesis, containing a two-sided steel and cobalt chrome cup, was tested with a TORNIER hip joint simulator in calf serum. The rubbed surfaces were characterized using scanning electron microscopy (SEM), contact angle measurements, atomic force microscopy (AFM) and confocal fluorescence microscopy. All these multiscale characterization techniques (from nanoscale to millimeter and micro- scale) showed that the velocity accommodation mechanism is different from one type of polyethylene to another. The wear in the case of standard polyethylene was noticeable and the particles were large and scattered between the surface of polyethylene, the surface of the cup and in the calf serum. For the crosslinked polyethylene, the particles coming from the wear, were not as large, but they were spread the same way as the first case. Even though it shares the same accommodation principle on the detachment of the material with the crosslinked polyethylene the wear particles for the crosslinked vitaminized polyethylene were large and they were only found on the surface of the polyethylene.
Low speed vehicle passenger ejection restraint effectiveness.
Seluga, Kristopher J; Ojalvo, Irving U; Obert, Richard M
2005-07-01
Current golf carts and LSV's (Low Speed Vehicles) produce a significant number of passenger ejections during sharp turns. These LSV's do not typically possess seatbelts, but do provide outboard bench seat hip restraints that also serve as handholds. However, many current restraint designs appear incapable of preventing passenger ejections due to their low height and inefficient handhold position. Alternative handhold and hip restraint designs may improve passenger safety. Accordingly, this paper examines minimum size requirements for hip restraints to prevent passenger ejection during sharp turns and evaluates the effectiveness of a handhold mounted at the center of the bench seat. In this study, a simulation of a turning cart supplies the dynamic input to a biomechanical model of an adult male seated in a golf cart. Various restraint combinations are considered, both with and without the central handhold, to determine the likelihood of passenger ejection. It is shown that only the largest restraint geometries prevent passenger ejection. Adequate hip restraints should be much larger than current designs and a central handhold should be provided. In this way, golf cart and LSV manufacturers could reduce passenger ejections and improve fleet safety by incorporating recommendations provided herein.
Sugand, Kapil; Wescott, Robert A; Carrington, Richard; Hart, Alister; Van Duren, Bernard H
2018-05-10
Background and purpose - Simulation is an adjunct to surgical education. However, nothing can accurately simulate fluoroscopic procedures in orthopedic trauma. Current options for training with fluoroscopy are either intraoperative, which risks radiation, or use of expensive and unrealistic virtual reality simulators. We introduce FluoroSim, an inexpensive digital fluoroscopy simulator without the need for radiation. Patients and methods - This was a multicenter study with 26 surgeons in which everyone completed 1 attempt at inserting a guide-wire into a femoral dry bone using surgical equipment and FluoroSim. 5 objective performance metrics were recorded in real-time to assess construct validity. The surgeons were categorized based on the number of dynamic hip screws (DHS) performed: novices (< 10), intermediates (10-39) and experts (≥ 40). A 7-point Likert scale questionnaire assessed the face and content validity of FluoroSim. Results - Construct validity was present for 2 clinically validated metrics in DHS surgery. Experts and intermediates statistically significantly outperformed novices for tip-apex distance and for cut-out rate. Novices took the least number of radiographs. Face and content validity were also observed. Interpretation - FluoroSim discriminated between novice and intermediate or expert surgeons based on tip-apex distance and cut-out rate while demonstrating face and content validity. FluoroSim provides a useful adjunct to orthopedic training. Our findings concur with results from studies using other simulation modalities. FluoroSim can be implemented for education easily and cheaply away from theater in a safe and controlled environment.
Investigation of Wear and Corrosion of a High-Carbon Stellite Alloy for Hip Implants
NASA Astrophysics Data System (ADS)
Hu, P. S.; Liu, R.; Liu, J.; McRae, G.
2014-04-01
Low-carbon Stellite 21 has been used as hip implant material for a number of decades; however, its limited metal-on-metal bearing has resulted in loosening between the femoral head and the acetabular cup of hip implants. In order to improve the metal-on-metal bearing, it is proposed that a high-carbon alloy, Stellite 720, surface coating be applied on Stellite 21 hip implants to improve mechanical and tribological performance. For this coating to be practical, it must also meet the requirements of corrosion resistance for orthopedic implant materials. In this research, Stellite 720 is investigated with pin-on-disk wear tests, and electrochemical and immersion corrosion tests in simulated human body fluid (Hank's solution; pH 7.4 at temperature of 37°C). The experimental results demonstrate that Stellite 720 exhibits much better wear resistance than Stellite 21, and has the potential for better corrosion resistance as well. The applicability of coating Stellite 21 hip implants with Stellite 720 is discussed.
Raichlen, David A
2008-09-01
The dynamic similarity hypothesis (DSH) suggests that differences in animal locomotor biomechanics are due mostly to differences in size. According to the DSH, when the ratios of inertial to gravitational forces are equal between two animals that differ in size [e.g. at equal Froude numbers, where Froude = velocity2/(gravity x hip height)], their movements can be made similar by multiplying all time durations by one constant, all forces by a second constant and all linear distances by a third constant. The DSH has been generally supported by numerous comparative studies showing that as inertial forces differ (i.e. differences in the centripetal force acting on the animal due to variation in hip heights), animals walk with dynamic similarity. However, humans walking in simulated reduced gravity do not walk with dynamically similar kinematics. The simulated gravity experiments did not completely account for the effects of gravity on all body segments, and the importance of gravity in the DSH requires further examination. This study uses a kinematic model to predict the effects of gravity on human locomotion, taking into account both the effects of gravitational forces on the upper body and on the limbs. Results show that dynamic similarity is maintained in altered gravitational environments. Thus, the DSH does account for differences in the inertial forces governing locomotion (e.g. differences in hip height) as well as differences in the gravitational forces governing locomotion.
Study of the impact of artificial articulations on the dose distribution under medical irradiation
NASA Astrophysics Data System (ADS)
Buffard, E.; Gschwind, R.; Makovicka, L.; Martin, E.; Meunier, C.; David, C.
2005-02-01
Perturbations due to the presence of high density heterogeneities in the body are not correctly taken into account in the Treatment Planning Systems currently available for external radiotherapy. For this reason, the accuracy of the dose distribution calculations has to be improved by using Monte Carlo simulations. In a previous study, we established a theoretical model by using the Monte Carlo code EGSnrc [I. Kawrakow, D.W.O. Rogers, The EGSnrc code system: MC simulation of electron and photon transport. Technical Report PIRS-701, NRCC, Ottawa, Canada, 2000] in order to obtain the dose distributions around simple heterogeneities. These simulations were then validated by experimental results obtained with thermoluminescent dosemeters and an ionisation chamber. The influence of samples composed of hip prostheses materials (titanium alloy and steel) and a substitute of bone were notably studied. A more complex model was then developed with the Monte Carlo code BEAMnrc [D.W.O. Rogers, C.M. MA, G.X. Ding, B. Walters, D. Sheikh-Bagheri, G.G. Zhang, BEAMnrc Users Manual. NRC Report PPIRS 509(a) rev F, 2001] in order to take into account the hip prosthesis geometry. The simulation results were compared to experimental measurements performed in a water phantom, in the case of a standard treatment of a pelvic cancer for one of the beams passing through the implant. These results have shown the great influence of the prostheses on the dose distribution.
A validated method for modeling anthropoid hip abduction in silico.
Hammond, Ashley S; Plavcan, J Michael; Ward, Carol V
2016-07-01
The ability to reconstruct hip joint mobility from femora and pelves could provide insight into the locomotion and paleobiology of fossil primates. This study presents a method for modeling hip abduction in anthropoids validated with in vivo data. Hip abduction simulations were performed on a large sample of anthropoids. The modeling approach integrates three-dimensional (3D) polygonal models created from laser surface scans of bones, 3D landmark data, and shape analysis software to digitally articulate and manipulate the hip joint. Range of femoral abduction (degrees) and the abducted knee position (distance spanned at the knee during abduction) were compared with published live animal data. The models accurately estimate knee position and (to a lesser extent) angular abduction across broad locomotor groups. They tend to underestimate abduction for acrobatic or suspensory taxa, but overestimate it in more stereotyped taxa. Correspondence between in vivo and in silico data varies at the specific and generic level. Our models broadly correspond to in vivo data on hip abduction, although the relationship between the models and live animal data is less straightforward than hypothesized. The models can predict acrobatic or stereotyped locomotor adaptation for taxa with values near the extremes of the range of abduction ability. Our findings underscore the difficulties associated with modeling complex systems and the importance of validating in silico models. They suggest that models of joint mobility can offer additional insight into the functional abilities of extinct primates when done in consideration of how joints move and function in vivo. Am J Phys Anthropol 160:529-548, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crapps, Justin M.; Clarke, Kester D.; Katz, Joel D.
2012-06-06
We use experimentation and finite element modeling to study a Hot Isostatic Press (HIP) manufacturing process for U-10Mo Monolithic Fuel Plates. Finite element simulations are used to identify the material properties affecting the process and improve the process geometry. Accounting for the high temperature material properties and plasticity is important to obtain qualitative agreement between model and experimental results. The model allows us to improve the process geometry and provide guidance on selection of material and finish conditions for the process strongbacks. We conclude that the HIP can must be fully filled to provide uniform normal stress across the bondingmore » interface.« less
The impact of surface and geometry on coefficient of friction of artificial hip joints.
Choudhury, Dipankar; Vrbka, Martin; Mamat, Azuddin Bin; Stavness, Ian; Roy, Chanchal K; Mootanah, Rajshree; Krupka, Ivan
2017-08-01
Coefficient of friction (COF) tests were conducted on 28-mm and 36-mm-diameter hip joint prostheses for four different material combinations, with or without the presence of Ultra High Molecular Weight Polyethylene (UHMWPE) particles using a novel pendulum hip simulator. The effects of three micro dimpled arrays on femoral head against a polyethylene and a metallic cup were also investigated. Clearance played a vital role in the COF of ceramic on polyethylene and ceramic on ceramic artificial hip joints. Micro dimpled metallic femoral heads yielded higher COF against a polyethylene cup; however, with metal on metal prostheses the dimpled arrays significantly reduced the COF. In situ images revealed evidence that the dimple arrays enhanced film formation, which was the main mechanism that contributed to reduced friction. Copyright © 2017 Elsevier Ltd. All rights reserved.
Altered mechano-chemical environment in hip articular cartilage: effect of obesity.
Travascio, Francesco; Eltoukhy, Moataz; Cami, Sonila; Asfour, Shihab
2014-10-01
The production of extracellular matrix (ECM) components of articular cartilage is regulated, among other factors, by an intercellular signaling mechanism mediated by the interaction of cell surface receptors (CSR) with insulin-like growth factor-1 (IGF-1). In ECM, the presence of binding proteins (IGFBP) hinders IGF-1 delivery to CSR. It has been reported that levels of IGF-1 and IGFBP in obese population are, respectively, lower and higher than those found in normal population. In this study, an experimental-numerical approach was adopted to quantify the effect of this metabolic alteration found in obese population on the homeostasis of femoral hip cartilage. A new computational model, based on the mechano-electrochemical mixture theory, was developed to describe competitive binding kinetics of IGF-1 with IGFBP and CSR, and associated glycosaminoglycan (GAG) biosynthesis. Moreover, a gait analysis was carried out on obese and normal subjects to experimentally characterize mechanical loads on hip cartilage during walking. This information was deployed into the model to account for effects of physiologically relevant tissue deformation on GAG production in ECM. Numerical simulations were performed to compare GAG biosynthesis in femoral hip cartilage of normal and obese subjects. Results indicated that the lower ratio of IGF-1 to IGFBP found in obese population reduces cartilage GAG concentration up to 18 % when compared to normal population. Moreover, moderate physical activity, such as walking, has a modest beneficial effect on GAG production. The findings of this study suggest that IGF-1/IGFBP metabolic unbalance should be accounted for when considering the association of obesity with hip osteoarthritis.
Choudhury, Dipankar; Rebenda, David; Sasaki, Shinya; Hekrle, Pavel; Vrbka, Martin; Zou, Min
2018-05-01
This study evaluates the impact of dimple shapes on lubricant film formation in artificial hip joints. Micro-dimples with 20-50 µm lateral size and 1 ± 0.2 µm depths were fabricated on CrCoMo hip joint femoral heads using a picosecond laser. Tribological studies were performed using a pendulum hip joint simulator to apply continuous swing flexion-extension motions. The results revealed a significantly enhanced lubricant film thickness (≥ 500 nm) with micro-dimpled prosthesis heads at equilibrium position after the lubricant film has fully developed. The average lubricant film thickness of dimpled prostheses with square- and triangular-shaped dimple arrays over time is about 3.5 that of the non-dimpled prosthesis (204 nm). Remarkably, the prosthesis with square-shaped dimple arrays showed a very fast lubricant film formation reaching their peak values within 0.5 s of pendulum movement, followed by prosthesis with triangular-shaped dimple arrays with a transition period of 42.4 s. The fully developed lubricant film thicknesses (≥ 700 nm) are significantly higher than the surface roughness (≈ 25 nm) demonstrating a hydrodynamic lubrication. Hardly any scratches appeared on the post-experimental prosthesis with square-shaped dimple array and only a few scratches were found on the post-experimental prosthesis with triangular-shaped dimple arrays. Thus, prostheses with square-shaped dimple arrays could be a potential solution for durable artificial hip joints. Copyright © 2018 Elsevier Ltd. All rights reserved.
Nataraj, Raviraj; Audu, Musa L; Kirsch, Robert F; Triolo, Ronald J
2010-12-01
Previous investigations of feedback control of standing after spinal cord injury (SCI) using functional neuromuscular stimulation (FNS) have primarily targeted individual joints. This study assesses the potential efficacy of comprehensive (trunk, hips, knees, and ankles) joint feedback control against postural disturbances using a bipedal, 3-D computer model of SCI stance. Proportional-derivative feedback drove an artificial neural network trained to produce muscle excitation patterns consistent with maximal joint stiffness values achievable about neutral stance given typical SCI muscle properties. Feedback gains were optimized to minimize upper extremity (UE) loading required to stabilize against disturbances. Compared to the baseline case of maximum constant muscle excitations used clinically, the controller reduced UE loading by 55% in resisting external force perturbations and by 84% during simulated one-arm functional tasks. Performance was most sensitive to inaccurate measurements of ankle plantar/dorsiflexion position and hip ab/adduction velocity feedback. In conclusion, comprehensive joint feedback demonstrates potential to markedly improve FNS standing function. However, alternative control structures capable of effective performance with fewer sensor-based feedback parameters may better facilitate clinical usage.
Nataraj, Raviraj; Audu, Musa L.; Kirsch, Robert F.; Triolo, Ronald J.
2013-01-01
Previous investigations of feedback control of standing after spinal cord injury (SCI) using functional neuromuscular stimulation (FNS) have primarily targeted individual joints. This study assesses the potential efficacy of comprehensive (trunk, hips, knees, and ankles) joint-feedback control against postural disturbances using a bipedal, three-dimensional computer model of SCI stance. Proportional-derivative feedback drove an artificial neural network trained to produce muscle excitation patterns consistent with maximal joint stiffness values achievable about neutral stance given typical SCI muscle properties. Feedback gains were optimized to minimize upper extremity (UE) loading required to stabilize against disturbances. Compared to the baseline case of maximum constant muscle excitations used clinically, the controller reduced UE loading by 55% in resisting external force perturbations and by 84% during simulated one-arm functional tasks. Performance was most sensitive to inaccurate measurements of ankle plantar/dorsiflexion position and hip ab/adduction velocity feedback. In conclusion, comprehensive joint-feedback demonstrates potential to markedly improve FNS standing function. However, alternative control structures capable of effective performance with fewer sensor-based feedback parameters may better facilitate clinical usage. PMID:20923741
Validation of a Dry Model for Assessing the Performance of Arthroscopic Hip Labral Repair.
Phillips, Lisa; Cheung, Jeffrey J H; Whelan, Daniel B; Murnaghan, Michael Lucas; Chahal, Jas; Theodoropoulos, John; Ogilvie-Harris, Darrell; Macniven, Ian; Dwyer, Tim
2017-07-01
Arthroscopic hip labral repair is a technically challenging and demanding surgical technique with a steep learning curve. Arthroscopic simulation allows trainees to develop these skills in a safe environment. The purpose of this study was to evaluate the use of a combination of assessment ratings for the performance of arthroscopic hip labral repair on a dry model. Cross-sectional study; Level of evidence, 3. A total of 47 participants including orthopaedic surgery residents (n = 37), sports medicine fellows (n = 5), and staff surgeons (n = 5) performed arthroscopic hip labral repair on a dry model. Prior arthroscopic experience was noted. Participants were evaluated by 2 orthopaedic surgeons using a task-specific checklist, the Arthroscopic Surgical Skill Evaluation Tool (ASSET), task completion time, and a final global rating scale. All procedures were video-recorded and scored by an orthopaedic fellow blinded to the level of training of each participant. The internal consistency/reliability (Cronbach alpha) using the total ASSET score for the procedure was high (intraclass correlation coefficient > 0.9). One-way analysis of variance for the total ASSET score demonstrated a difference between participants based on the level of training ( F 3,43 = 27.8, P < .001). A good correlation was seen between the ASSET score and previous exposure to arthroscopic procedures ( r = 0.52-0.73, P < .001). The interrater reliability for the ASSET score was excellent (>0.9). The results of this study demonstrate that the use of dry models to assess the performance of arthroscopic hip labral repair by trainees is both valid and reliable. Further research will be required to demonstrate a correlation with performance on cadaveric specimens or in the operating room.
Type of motion and lubricant in wear simulation of polyethylene acetabular cup.
Saikko, V; Ahlroos, T
1999-01-01
The wear of ultra-high molecular weight polyethylene, the most commonly used bearing material in prosthetic joints, is often substantial, posing a significant clinical problem. For a long time, there has been a need for simple but still realistic wear test devices for prosthetic joint materials. The wear factors produced by earlier reciprocating and unidirectionally rotating wear test devices for polyethylene are typically two orders of magnitude too low, both in water and in serum lubrication. Wear is negligible even under multidirectional motion in water. A twelve-station, circularly translating pin-on-disc (CTPOD) device and a modification of the established biaxial rocking motion hip joint simulator were built. With these simple and inexpensive devices, and with the established three-axis hip joint simulator, realistic wear simulation was achieved. This was due to serum lubrication and to the fact that the direction of sliding constantly changed relative to the polyethylene specimen. The type and magnitude of load was found to be less important. The CTPOD tests showed that the subsurface brittle region, which results from gamma irradiation sterilization of polyethylene in air, has poor wear resistance. Phospholipid and soy protein lubrication resulted in unrealistic wear. The introduction of devices like CTPOD may boost wear studies, rendering them feasible without heavy investment.
A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface.
Choudhury, Dipankar; Urban, Filip; Vrbka, Martin; Hartl, Martin; Krupka, Ivan
2015-05-01
This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer. Copyright © 2015 Elsevier Ltd. All rights reserved.
Factors influencing initial cup stability in total hip arthroplasty.
Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad
2014-12-01
One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mather, Richard C; Nho, Shane J; Federer, Andrew; Demiralp, Berna; Nguyen, Jennifer; Saavoss, Asha; Salata, Michael J; Philippon, Marc J; Bedi, Asheesh; Larson, Christopher M; Byrd, J W Thomas; Koenig, Lane
2018-04-01
The diagnosis and treatment of femoroacetabular impingement (FAI) have increased steadily within the past decade, and research indicates clinically significant improvements after treatment of FAI with hip arthroscopy. This study examined the societal and economic impact of hip arthroscopy by high-volume surgeons for patients with FAI syndrome aged <50 years with noncontroversial diagnosis and indications for surgery. Economic and decision analysis; Level of evidence, 2. The cost-effectiveness of hip arthroscopy versus nonoperative treatment was evaluated by calculating direct and indirect treatment costs. Direct cost was calculated with Current Procedural Terminology medical codes associated with FAI treatment. Indirect cost was measured with the patient-reported data of 102 patients who underwent arthroscopy and from the reimbursement records of 32,143 individuals between the ages of 16 and 79 years who had information in a private insurance claims data set contained within the PearlDiver Patient Records Database. The indirect economic benefits of hip arthroscopy were inferred through regression analysis to estimate the statistical relationship between functional status and productivity. A simulation-based approach was then used to estimate the change in productivity associated with the change in functional status observed in the treatment cohort between baseline and follow-up. To analyze cost-effectiveness, 1-, 2-, and 3-way sensitivity analyses were performed on all variables in the model, and Monte Carlo analysis evaluated the impact of uncertainty in the model assumptions. Analysis of indirect costs identified a statistically significant increase of mean aggregate productivity of $8968 after surgery. Cost-effectiveness analysis showed a mean cumulative total 10-year societal savings of $67,418 per patient from hip arthroscopy versus nonoperative treatment. Hip arthroscopy also conferred a gain of 2.03 quality-adjusted life years over this period. The mean cost for hip arthroscopy was estimated at $23,120 ± $10,279, and the mean cost of nonoperative treatment was estimated at $91,602 ± $14,675. In 99% of trials, hip arthroscopy was recognized as the preferred cost-effective strategy. FAI syndrome produces a substantial economic burden on society that may be reduced through the indirect cost savings and economic benefits from hip arthroscopy.
Summary of Calcine Disposal Development Using Hot Isostatic Pressing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bateman, Ken; Wahlquist, Dennis; Hart, Edward
2015-03-01
Battelle Energy Alliance, LLC, has demonstrated the effectiveness of the hot isostatic press (HIP) process for treatment of hazardous high-level waste known as calcine that is stored at the Idaho Nuclear Technology and Engineering Center (INTEC) at Idaho National Laboratory. HIP trials performed with simulated calcines at Idaho National Laboratory’s Materials and Fuels Complex and an Australian Nuclear Science and Technology Organization facility from 2007 to 2010 produced a dense, monolithic waste form with increased chemical durability and effective (storage) volume reductions of ~10 to ~70% compared to granular calcine forms. In December 2009, the U.S. Department of Energy signedmore » an amended Record of Decision selecting HIP technology as the treatment method for the 4,400 m3 of granular zirconia and alumina calcine stored at INTEC. Testing showed that HIP treatment reduces the risks associated with radioactive and hazardous constituent release, post-production handling, and long-term (repository) storage of calcines and would result in estimated storage cost savings in the billions of dollars. Battelle Energy Alliance has the ability to complete pilot-scale HIP processing of INTEC calcine, which is the next necessary step in implementing HIP processing as a calcine treatment method.« less
Biotribology of Cartilage Wear in Knee and Hip Joints Review of Recent Developments
NASA Astrophysics Data System (ADS)
Gulsen, Akdogan; Merve, Goncu; Meltem, Parlak
2018-01-01
Nowadays, the problem of wear in the knee and hip joints is an important issue that concerns many people and still requires new solutions. In recent years, researchers dealing with knee and hip articular cartilage erosion continue to investigate the subject in terms of biotribology. In this study, recent developments and studies in this relevant area are been examined. By using the basic principles of tribology, useful new methods that can be used in the field of biotribology can be produced. Artificial joints designed using various materials such as metals, ceramics, polymers and composites are still being studied. New studies in this area will affect the development of implant technology. Different alloys or composites are currently being tested for new implant designs. Moving implants with a risk of wear are tested in laboratory conditions in simulator devices before they are used in the human body. Major topics such as nanotechnology, tissue engineering, orthopedics, tribology, biotribology, lubrication, organ transplantation and artificial organs, which are still important today, will be useful in the search for finding suitable solutions in the future in biotribological studies. This review article aims to provide an overview of in-vitro studies at the theoretical and laboratory conditions that must be performed prior to clinical investigation.
Artificial Hip Simulator with Crystal Models
1966-06-21
Robert Johnson, top, sets the lubricant flow while Donald Buckley adjusts the bearing specimen on an artificial hip simulator at the National Aeronautics and Space Administration (NASA) Lewis Research Center. The simulator was supplemented by large crystal lattice models to demonstrate the composition of different bearing alloys. This this image by NASA photographer Paul Riedel was used for the cover of the August 15, 1966 edition of McGraw-Hill Product Engineering. Johnson was chief of Lubrication Branch and Buckley head of the Space Environment Lubrication Section in the Fluid System Components Division. In 1962 they began studying the molecular structure of metals. Their friction and wear testing revealed that the optimal structure for metal bearings was a hexagonal crystal structure with proper molecular space. Bearing manufacturers traditionally preferred cubic structures over hexagonal arrangements. Buckley and Johnson found that even though the hexagonal structural was not as inherently strong as its cubic counterpart, it was less likely to cause a catastrophic failure. The Lewis researchers concentrated their efforts on cobalt-molybdenum and titanium alloys for high temperatures applications. The alloys had a number of possible uses, included prosthetics. The alloys were similar in composition to the commercial alloys used for prosthetics, but employed the longer lasting hexagonal structure.
Heterogeneity image patch index and its application to consumer video summarization.
Dang, Chinh T; Radha, Hayder
2014-06-01
Automatic video summarization is indispensable for fast browsing and efficient management of large video libraries. In this paper, we introduce an image feature that we refer to as heterogeneity image patch (HIP) index. The proposed HIP index provides a new entropy-based measure of the heterogeneity of patches within any picture. By evaluating this index for every frame in a video sequence, we generate a HIP curve for that sequence. We exploit the HIP curve in solving two categories of video summarization applications: key frame extraction and dynamic video skimming. Under the key frame extraction frame-work, a set of candidate key frames is selected from abundant video frames based on the HIP curve. Then, a proposed patch-based image dissimilarity measure is used to create affinity matrix of these candidates. Finally, a set of key frames is extracted from the affinity matrix using a min–max based algorithm. Under video skimming, we propose a method to measure the distance between a video and its skimmed representation. The video skimming problem is then mapped into an optimization framework and solved by minimizing a HIP-based distance for a set of extracted excerpts. The HIP framework is pixel-based and does not require semantic information or complex camera motion estimation. Our simulation results are based on experiments performed on consumer videos and are compared with state-of-the-art methods. It is shown that the HIP approach outperforms other leading methods, while maintaining low complexity.
Zanini, Filippo; Carmignato, Simone
2017-01-01
More than 60.000 hip arthroplasty are performed every year in Italy. Although Ultra-High-Molecular-Weight-Polyethylene remains the most used material as acetabular cup, wear of this material induces over time in vivo a foreign-body response and consequently osteolysis, pain, and the need of implant revision. Furthermore, oxidative wear of the polyethylene provoke several and severe failures. To solve these problems, highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years. In in vitro experiments, various efforts have been made to compare the wear behavior of standard PE and vitamin-E infused liners. In this study we compared the in vitro wear behavior of two different configurations of cross-linked polyethylene (with and without the add of Vitamin E) vs. the standard polyethylene acetabular cups. The aim of the present study was to validate a micro X-ray computed tomography technique to assess the wear of different commercially available, polyethylene’s acetabular cups after wear simulation; in particular, the gravimetric method was used to provide reference wear values. The agreement between the two methods is documented in this paper. PMID:28107468
NASA Astrophysics Data System (ADS)
Oldani, C. R.; Dominguez, A. A.
2007-11-01
In a previous work a finite elements model was constructed to simulate a fatigue assay according to the norm IRAM 9422-3. Three materials were studied, two of them are the most used in this type of implant (Stainless steel 3161 and alloy T16A14V) and the third was a new developed titanium alloy (Ti35Nb7Zr5Ta). Static loads were applied to the model according to the highest requirements of the norm and the stress - strain distribution were determined. In this study a simplified analysis of the material's fatigue was done according to the previous work. The best behavior of the titanium alloys vs. the stainless steel was evident. With the objective of studying the behavior of both: the implant and the femur bone, new finite elements models were realized, in which the presence of the bone was considered. Inside the bone, the femoral component of the implant was placed in a similar way of a cemented prosthesis in a total hip arthroplasty. The advantage of the titanium implant related to the stainless steel one, was very clear.
Revision Hip Arthroscopy: A Systematic Review of Diagnoses, Operative Findings, and Outcomes.
Cvetanovich, Gregory L; Harris, Joshua D; Erickson, Brandon J; Bach, Bernard R; Bush-Joseph, Charles A; Nho, Shane J
2015-07-01
To determine indications for, operative findings of, and outcomes of revision hip arthroscopy. A systematic review was registered with PROSPERO and performed based on PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Therapeutic clinical outcome studies reporting the indications for, operative findings of, and outcomes of revision hip arthroscopy were eligible for inclusion. All study-, patient-, and hip-specific data were extracted and analyzed. The Modified Coleman Methodology Score was used to assess study quality. Five studies were included (348 revision hip arthroscopies; 333 patients; mean age, 31.4 ± 4.2 years; 60% female patients). All 5 studies were either Level III or IV evidence. The surgeon performing revision hip arthroscopy was the same as the primary hip surgeon in only 25% of cases. The mean time between primary and revision hip arthroscopy was 27.8 ± 7.0 months (range, 2 to 193 months). Residual femoroacetabular impingement was the most common indication for and operative finding of revision hip arthroscopy (81% of cases). The most commonly reported revision procedures were femoral osteochondroplasty (24%) and acetabuloplasty (18%). The modified Harris Hip Score was used in all 5 analyzed studies, with significant (P < .05) improvements observed in all 5 studies (weighted mean, 56.8 ± 3.6 preoperatively v 72.0 ± 8.3 at final follow-up [22.4 ± 9.8 months]; P = .01). Other patient-reported outcomes (Non-Arthritic Hip Score, Hip Outcome Score, 33-item International Hip Outcome Tool, Short Form 12) showed significant improvements but were not used in all 5 analyzed studies. After revision hip arthroscopy, subsequent reported operations were hip arthroplasty in 11 patients and re-revision hip arthroscopy in 8 patients (5% total reoperation rate). Revision hip arthroscopy is most commonly performed for residual femoroacetabular impingement, with statistically significant and clinically relevant improvements shown in multiple patient-reported clinical outcome scores at short-term follow-up. The reoperation rate after revision hip arthroscopy is 5% within 2 years, including further arthroscopy or conversion to hip arthroplasty. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Preliminary Modeling of Accident Tolerant Fuel Concepts under Accident Conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamble, Kyle A.; Hales, Jason D.
2016-12-01
The catastrophic events that occurred at the Fukushima-Daiichi nuclear power plant in 2011 have led to widespread interest in research of alternative fuels and claddings that are proposed to be accident tolerant. Thus, the United States Department of Energy through its NEAMS (Nuclear Energy Advanced Modeling and Simulation) program has funded an Accident Tolerant Fuel (ATF) High Impact Problem (HIP). The ATF HIP is funded for a three-year period. The purpose of the HIP is to perform research into two potential accident tolerant concepts and provide an in-depth report to the Advanced Fuels Campaign (AFC) describing the behavior of themore » concepts, both of which are being considered for inclusion in a lead test assembly scheduled for placement into a commercial reactor in 2022. The initial focus of the HIP is on uranium silicide fuel and iron-chromium-aluminum (FeCrAl) alloy cladding. Utilizing the expertise of three national laboratory participants (INL, LANL, and ANL) a comprehensive mulitscale approach to modeling is being used including atomistic modeling, molecular dynamics, rate theory, phase-field, and fuel performance simulations. In this paper, we present simulations of two proposed accident tolerant fuel systems: U3Si2 fuel with Zircaloy-4 cladding, and UO2 fuel with FeCrAl cladding. The simulations investigate the fuel performance response of the proposed ATF systems under Loss of Coolant and Station Blackout conditions using the BISON code. Sensitivity analyses are completed using Sandia National Laboratories’ DAKOTA software to determine which input parameters (e.g., fuel specific heat) have the greatest influence on the output metrics of interest (e.g., fuel centerline temperature). Early results indicate that each concept has significant advantages as well as areas of concern. Further work is required prior to formulating the proposition report for the Advanced Fuels Campaign.« less
Unconstrained tripolar hip implants: effect on hip stability.
Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan
2007-02-01
Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.
The neck shaft angle: CT reference values of 800 adult hips.
Boese, Christoph Kolja; Jostmeier, Janine; Oppermann, Johannes; Dargel, Jens; Chang, De-Hua; Eysel, Peer; Lechler, Philipp
2016-04-01
A precise understanding of the radiological anatomy and biomechanics as well as reliable reference values of the hip are essential. The primary goal of this study was to provide reference values of the neck-shaft angle (NSA) for adult patients based on the analysis of rotation corrected computed tomography (CT) scans of 800 hips. The secondary aim was to compare these measurements with simulated anteroposterior roentgenograms of the pelvis. Pelvic CT scans of 400 patients (54.3 years, range 18-100 years; 200 female) were reconstructed in the derotated coronal plane of the proximal femur and as CT-based simulated anteroposterior roentgenograms of the pelvis in the anterior pelvic plane. Femora were categorized as coxa vara (<120°), physiologic (≥120° to <135°), and coxa valga (≥135°). Intra- and inter-rater reliability were analyzed. Primary research question: Mean NSA for male adults was 129.6° (range 113.2°-148.2°; SD 5.9°) and 131.9° (range 107.1°-151.9°; SD 6.8°) for females in derotated coronal reconstructions. Age (p < 0.001 in both views) and sex influenced the NSA significantly (p = 0.002 and p < 0.001); no significant differences were found between sides (p = 0.722 and p = 0.955). Overall, an excellent reliability of repeated measurements of one or two observers was found (ICC 0.891-0.995). Secondary research question: NSA values measured in the simulated anteroposterior roentgenogram and the rotation corrected coronal reconstruction differed significantly (p < 0.001). While anteroposterior pelvis radiographs are susceptible to rotational errors, the coronal reconstruction of the proximal femur in the femoral neck plane allows the correct measurement of the NSA.
Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.
Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John
2008-08-01
Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.
Loading of Hip Measured by Hip Contact Forces at Different Speeds of Walking and Running.
Giarmatzis, Georgios; Jonkers, Ilse; Wesseling, Mariska; Van Rossom, Sam; Verschueren, Sabine
2015-08-01
Exercise plays a pivotal role in maximizing peak bone mass in adulthood and maintaining it through aging, by imposing mechanical loading on the bone that can trigger bone mineralization and growth. The optimal type and intensity of exercise that best enhances bone strength remains, however, poorly characterized, partly because the exact peak loading of the bone produced by the diverse types of exercises is not known. By means of integrated motion capture as an input to dynamic simulations, contact forces acting on the hip of 20 young healthy adults were calculated during walking and running at different speeds. During walking, hip contact forces (HCFs) have a two-peak profile whereby the first peak increases from 4.22 body weight (BW) to 5.41 BW and the second from 4.37 BW to 5.74 BW, by increasing speed from 3 to 6 km/h. During running, there is only one peak HCF that increases from 7.49 BW to 10.01 BW, by increasing speed from 6 to 12 km/h. Speed related profiles of peak HCFs and ground reaction forces (GRFs) reveal a different progression of the two peaks during walking. Speed has a stronger impact on peak HCFs rather than on peak GRFs during walking and running, suggesting an increasing influence of muscle activity on peak HCF with increased speed. Moreover, results show that the first peak of HCF during walking can be predicted best by hip adduction moment, and the second peak of HCF by hip extension moment. During running, peak HCF can be best predicted by hip adduction moment. The present study contributes hereby to a better understanding of musculoskeletal loading during walking and running in a wide range of speeds, offering valuable information to clinicians and scientists exploring bone loading as a possible nonpharmacological osteogenic stimulus. © 2015 American Society for Bone and Mineral Research. © 2015 American Society for Bone and Mineral Research.
Ruggiero, Alessandro; Merola, Massimiliano; Affatato, Saverio
2018-04-09
The hip joint replacement is one of the most successful orthopedic surgical procedures although it involves challenges to overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime for the replacement joint. It is well known that wear tests have a long duration and they are very expensive, thus studying the effects of geometry, loading, or alignment perturbations may be performed by Finite Element Analysis. The aim of the study was to evaluate total deformation and stress intensity on ultra-high molecular weight polyethylene liner coupled with hard material head during one step. Moving toward in-silico wear assessment of implants, in the presented simulations we used a musculoskeletal multibody model of a human body giving the loading and relative kinematic of the investigated tribo-system during the gait. The analysis compared two frictional conditions -dry and wet and two geometrical cases- with and without radial clearance. The loads and rotations followed the variability of the gait cycle as well as stress/strain acting in the UHWMPE cup. The obtained results allowed collection of the complete stress/strain description of the polyethylene cup during the gait and calculation of the maximum contact pressure on the lateral edge of the insert. The tensional state resulted in being more influenced by the geometrical conditions in terms of radial clearance than by the variation of the friction coefficients due to lubrication phenomena.
Bragdon, Charles R; Malchau, Henrik; Yuan, Xunhua; Perinchief, Rebecca; Kärrholm, Johan; Börlin, Niclas; Estok, Daniel M; Harris, William H
2002-07-01
The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, Y
Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distributionmore » using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.« less
NASA Astrophysics Data System (ADS)
Palleri, Francesca; Baruffaldi, Fabio; Angelini, Anna Lisa; Ferri, Andrea; Spezi, Emiliano
2008-12-01
In external beam radiotherapy the calculation of dose distribution for patients with hip prostheses is critical. Metallic implants not only degrade the image quality but also perturb the dose distribution. Conventional treatment planning systems do not accurately account for high-Z prosthetic implants heterogeneities, especially at interfaces. The materials studied in this work have been chosen on the basis of a statistical investigation on the hip prostheses implanted in 70 medical centres. The first aim of this study is a systematic characterization of materials used for hip prostheses, and it has been provided by BEAMnrc Monte Carlo code. The second aim is to evaluate the capabilities of a specific treatment planning system, Pinnacle 3, when dealing with dose calculations in presence of metals, also close to the regions of high-Z gradients. In both cases it has been carried out an accurate comparison versus experimental measurements for two clinical photon beam energies (6 MV and 18 MV) and for two experimental sets-up: metallic cylinders inserted in a water phantom and in a specifically built PMMA slab. Our results show an agreement within 2% between experiments and MC simulations. TPS calculations agree with experiments within 3%.
Characteristics and Trends of Published Adult Hip Research over the Last Decade
Kwak, Hong Suk; Yoon, Pil Whan; Park, Moon Seok; Kim, Hee Joong
2015-01-01
Purpose We designed this study to demonstrate recent trends in the proportion of adult hip research in orthopedics, to identify countries leading the adult hip research, and to evaluate the relationship between the economic power of the countries and their contributions. Materials and Methods Studies published in seven select orthopedic journals were retrieved from PubMed. Among them, we determined the number of adult hip studies. The countries-of-origin of adult hip studies, and the economic power of the countries were investigated. Results A total of 7218 orthopedic publications and 1993 (27.6%) addressed adult hip research were identified. Adult hip studies increased from 313 (23.7%) in 2000 to 555 (27.9%) in 2011. Twenty-five countries accounted for 97.6% of the total number of adult hip studies, and gross domestic product correlated with publication volume (Spearman's rho, 0.723; p=0.000). Conclusion Researchers from a limited number of developed countries have published their studies in the adult hip discipline. PMID:25510756
Li, Chaodi; Kotha, Shiva; Mason, James
2003-01-01
The exothermic polymerization of bone cement may induce thermal necrosis of bone in cemented hip arthroplasty. A finite element formulation was developed to predict the evolution of the temperature with time in the cemented hip replacement system. The developed method is capable of taking into account both the chemical reaction that generates heat during bone cement polymerization (through a kinetic model) and the physical process of heat conduction (with an energy balance equation). The possibility of thermal necrosis of bone was then evaluated based on the temperature history in the bone and an appropriate damage criterion. Specifically, we evaluate the role of implant materials and designs on the thermal response of the system. Results indicated that the peak temperature at the bone/cement interface with a metal prosthesis was lower than that with a polymer or a composite prosthesis in hip replacement systems. Necrosis of bone was predicted to occur with a polymer or a composite prosthesis while no necrosis was predicted with a metal prosthesis in the simulated conditions. When reinforcing osteoporotic hips with injected bone cement in the cancellous core of the femur, the volume of bone cement implanted is increased which may increase the risk of thermal necrosis of bone. We evaluate whether this risk can be decreased through the use of an insulator to contain the bone cement. No thermal necrosis of bone was predicted with a 3 mm thick polyurethane insulator while more damage is predicted for the use of bone cement without the insulator. This method provides a numerical tool for the quantitative simulation of the thermal behavior of bone-cement-prosthesis designs and for examining and refining new designs computationally.
Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D
2016-03-01
The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.
van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A
2018-05-01
Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on workshop bone models. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
Ginja, Mário M D; Ferreira, António J; Jesus, Sandra S; Melo-Pinto, Pedro; Bulas-Cruz, José; Orden, Maria A; San-Roman, Fidel; Llorens-Pena, Maria P; Gonzalo-Orden, José M
2009-01-01
The purpose of the study was to use two palpation methods (Bardens and Ortolani), a radiographic distraction view, three computed tomography (CT) measurements (dorsolateral subluxation score, the lateral center-edge angle, and acetabular ventroversion angle) and two magnetic resonance (MR) imaging hip studies (synovial fluid and acetabular depth indices) in the early monitoring of hip morphology and laxity in 7-9 week old puppies; and in a follow-up study to compare their accuracy in predicting later hip laxity and dysplasia. The MR imaging study was performed with the dog in dorsal recumbency and the CT study with the animal in a weight-bearing position. There was no association between clinical laxity with later hip laxity or dysplasia. The dorsolateral subluxation score and the lateral center-edge angle were characterized by a weak negative correlation with later radiographic passive hip laxity (-0.26 < r < -0.38, P < 0.05) but its association with hip dysplasia was not significant. There was an association between early radiographic passive hip laxity and synovial fluid index with later passive hip laxity (0.41 < r < 0.55, P < 0.05) and this was significantly different in dysplastic vs. nondysplastic hips (P < 0.05). There was no association between the remaining variables and later hip laxity or dysplasia. The overlapping ranges of early passive hip laxity and synovial fluid index for hip dysplasia grades and the moderate correlations with the later passive hip laxity make the results of these variables unreliable for use in predicting hip laxity and dysplasia susceptibility.
Tribolayer Formation in a Metal-on-Metal (MoM) Hip Joint: An Electrochemical Investigation
Mathew, MT; Nagelli, C; Pourzal, R; Fischer, A; Laurent, MP; Jacobs, JJ; Wimmer, MA
2013-01-01
The demand for total hip replacement (THR) surgery is increasing in the younger population due to faster rehabilitation and more complete restoration of function. Up to 2009, metal-on-metal (MoM) hip joint bearings were a popular choice due to their design flexibility, post-operative stability and relatively low wear rates. The main wear mechanisms that occur along the bearing surface of MoM joints are tribochemical reactions that deposit a mixture of wear debris, metal ions and organic matrix of decomposed proteins known as a tribolayer. No in-depth electrochemical studies have been reported on the structure and characteristics of this tribolayer or about the parameters involved in its formation. In this study, we conducted an electrochemical investigation of different surfaces (bulk-like: control, nano-crystalline: new implant and tribolayer surface: retrieved implant) made out of two commonly used hip CoCrMo alloys (high-carbon and low-carbon). As per ASTM standard, cyclic polarization tests and electrochemical impedance spectroscopy tests were conducted. The results obtained from electrochemical parameters for different surfaces clearly indicated a reduction in corrosion for the tribolayer surface (Icorr: 0.76 μA/cm2). Further, polarization resistance (Rp:2.39±0.60MΩ/cm2) and capacitance (Cdl:15.20±0.75 μF/cm2) indicated variation in corrosion kinetics for the tribolayer surface, that attributed to its structure and stability in a simulated body environment. PMID:24099949
Fabrication and wear test of a continuous fiber/particulate composite total surface hip replacement
NASA Technical Reports Server (NTRS)
Roberts, J. C.; Ling, F. F.; Jones, W. R., Jr.
1981-01-01
Continuous fiber woven E-glass composite femoral shells having the ame elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle were tests on a total hip simulator. The tribological characteristics of these shells atriculating with the acetabular cups are comparable to a vitallium bal articulating with an ultrahigh molecular weight polyethylene cup.
Yamane, Shihori; Kyomoto, Masayuki; Moro, Toru; Hashimoto, Masami; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko
2018-04-01
Younger, active patients who undergo total hip arthroplasty (THA) have increasing needs for wider range of motion and improved stability of the joint. Therefore, bearing materials having not only higher wear resistance but also mechanical strength are required. Carbon fiber-reinforced poly(ether ether ketone) (CFR-PEEK) is known as a super engineering plastic that has great mechanical strength. In this study, we focused on poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted CFR-PEEK and investigated the effects of PMPC grafting and the femoral heads materials on the wear properties of CFR-PEEK liners. Compared with untreated CFR-PEEK, the PMPC-grafted CFR-PEEK surface revealed higher wettability and lower friction properties under aqueous circumstances. In the hip simulator wear test, wear particles generated from the PMPC-grafted CFR-PEEK liners were fewer than those of the untreated CFR-PEEK liners. There were no significant differences in the size and the morphology of the wear particles between the differences of PMPC-grafting and the counter femoral heads. Zirconia-toughened alumina (ZTA) femoral heads had significantly smoother surfaces compared to cobalt-chromium-molybdenum alloy femoral heads after the hip simulator test. Thus, we conclude that the bearing combination of the PMPC-grafted CFR-PEEK liner and ZTA head is expected to be a lifelong bearing interface in THA. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1028-1037, 2018. © 2017 Wiley Periodicals, Inc.
Walking patterns and hip contact forces in patients with hip dysplasia.
Skalshøi, Ole; Iversen, Christian Hauskov; Nielsen, Dennis Brandborg; Jacobsen, Julie; Mechlenburg, Inger; Søballe, Kjeld; Sørensen, Henrik
2015-10-01
Several studies have investigated walking characteristics in hip dysplasia patients, but so far none have described all hip rotational degrees of freedom during the whole gait cycle. This descriptive study reports 3D joint angles and torques, and furthermore extends previous studies with muscle and joint contact forces in 32 hip dysplasia patients and 32 matching controls. 3D motion capture data from walking and standing trials were analysed. Hip, knee, ankle and pelvis angles were calculated with inverse kinematics for both standing and walking trials. Hip, knee and ankle torques were calculated with inverse dynamics, while hip muscle and joint contact forces were calculated with static optimisation for the walking trials. No differences were found between the two groups while standing. While walking, patients showed decreased hip extension, increased ankle pronation and increased hip abduction and external rotation torques. Furthermore, hip muscle forces were generally lower and shifted to more posteriorly situated muscles, while the hip joint contact force was lower and directed more superiorly. During walking, patients showed lower and more superiorly directed hip joint contact force, which might alleviate pain from an antero-superiorly degenerated joint. Copyright © 2015 Elsevier B.V. All rights reserved.
Hip fractures: incidence, risk factors, energy absorption, and prevention.
Lauritzen, J B
1996-01-01
The present review summarizes the pathogenic mechanisms leading to hip fracture based on epidemiological, experimental, and controlled clinical studies. The estimated lifetime risk of hip fracture is about 14% in postmenopausal women and 6% in men. The incidence of hip fractures increases exponentially with aging, but the time trend in increasing age-specific incidence may finally reach a plateau. Postmenopausal women suffering earlier non-hip fractures have an increased risk of later hip fracture. The relative risk is highest within the first years following the fracture. Nursing home residents have a high risk of hip fracture (annual rate of 5-6%), and their incidence of falls is about 1.5 falls/person per year. Most hip fractures are a result of a direct trauma against the hip. The incidence of falls on the hip among nursing home residents is about 0.29 falls/person per year and about 20% of these traumas lead to hip fracture. Women with hip fractures have a lower body weight compared with controls, and they may also have less soft tissue covering the hip, even when adjusted for body mass index, indicating a more android body habitus. Experimental studies show that the passive energy absorption in soft tissue covering the hip may influence the risk of hip fracture and be an important determinant for the development of hip fracture, perhaps even more important than bone strength. External hip protectors were developed and tested in an open randomized nursing home study. The rate of hip fracture was reduced by 50%, corresponding to 9 of 247 residents saved from sustaining a hip fracture. This review points to the essentials in the development of hip fracture: risk of fall; type of fall; type of impact; energy absorption; and last, bone strength, which is the final permissive factor leading to hip fracture. Risk estimation and prevention of hip fracture may prove realistic when these issues are taken into consideration.
The stability of a hip fracture determines the fatigue of an intramedullary nail.
Eberle, S; Bauer, C; Gerber, C; von Oldenburg, G; Augat, P
2010-01-01
The purpose of this study was to address the question of how the stability of a proximal hip fracture determines the fatigue and failure mechanism of an intramedullary implant. To answer this question, mechanical experiments and finite element simulations with two different loading scenarios were conducted. The two load scenarios differed in the mechanical support of the fracture by an artificial bone sleeve, representing the femoral head and neck. The experiments confirmed that an intramedullary nail fails at a lower load in an unstable fracture situation in the proximal femur than in a stable fracture. The nails with an unstable support failed at a load 28 per cent lower than the nails with a stable support by the femoral neck. Hence, the mechanical support of a fracture is crucial to the fatigue failure of an implant. The simulation showed why the fatigue fracture of the nail starts at the aperture of the lag screw. It is the location of the highest von Mises stress, which is the failure criterion for ductile materials.
Chen, C Q; Scott, W; Barker, T M
1999-01-01
Bonding and loosening mechanisms between bone cement and joint prostheses have not been well identified. In this study, the effects of simulated hip stem surface topography on the interfacial shear strength were examined. Six different surface topographies were used. They were described by several surface characterization parameters that may directly relate to the interfacial bonding strength: average surface roughness R(a), root mean square slope R(Deltaq), correlation length beta, and fluid retention index R(ri). The shear strengths between Palacos E bone cement and stainless steel rods were measured using an Instron materials testing machine. We found that cement can "flow" into the surface microtopography and establish good contact with the metal surface. The results show that the interfacial strength increases monotonically with the increase of R(Deltaq) instead of with R(a). The relationship between interfacial strength and surface parameters shows that a metal stem with an isotropic surface texture, higher R(Deltaq), and greater R(ri) gives a higher interfacial strength. Copyright 1999 John Wiley & Sons, Inc.
Kianmajd, Babak; Carter, David; Soshi, Masakazu
2016-10-01
Robotic total hip arthroplasty is a procedure in which milling operations are performed on the femur to remove material for the insertion of a prosthetic implant. The robot performs the milling operation by following a sequential list of tool motions, also known as a toolpath, generated by a computer-aided manufacturing (CAM) software. The purpose of this paper is to explain a new toolpath force prediction algorithm that predicts cutting forces, which results in improving the quality and safety of surgical systems. With a custom macro developed in the CAM system's native application programming interface, cutting contact patch volume was extracted from CAM simulations. A time domain cutting force model was then developed through the use of a cutting force prediction algorithm. The second portion validated the algorithm by machining a hip canal in simulated bone using a CNC machine. Average cutting forces were measured during machining using a dynamometer and compared to the values predicted from CAM simulation data using the proposed method. The results showed the predicted forces matched the measured forces in both magnitude and overall pattern shape. However, due to inconsistent motion control, the time duration of the forces was slightly distorted. Nevertheless, the algorithm effectively predicted the forces throughout an entire hip canal procedure. This method provides a fast and easy technique for predicting cutting forces during orthopedic milling by utilizing data within a CAM software.
Hip fractures. Epidemiology, risk factors, falls, energy absorption, hip protectors, and prevention.
Lauritzen, J B
1997-04-01
The present review summarizes the pathogenic mechanisms leading to hip fracture based on epidemiological, experimental, and controlled studies. The estimated lifetime risk of hip fracture is about 14% in postmenopausal women and 6% in men. The incidence of hip fractures increases exponentially with aging, but the time-trend in increasing age-specific incidence may not be a universal phenomenon. Postmenopausal women suffering earlier non-hip fractures have an increased risk of later hip fracture. The relative risk being highest within the first years following the fracture. Nursing home residents have a high risk of hip fracture (annual rate of 5-6%), and the incidence of falls is about 1,500 falls/1,000 persons/year. Most hip fractures are a result of a direct trauma against the hip. The incidence of falls on the hip among nursing home residents is about 290 falls/1,000 persons/year and about 24% of these impacts lead to hip fracture. The force acting on the hip may reach 3.7 kN in falls on the hip from standing height, which means that only susceptible subjects will sustain a hip fracture in such falls. The effective load acting on the hip is 35% of the body weight in unprotected falls on the hip. Women with hip fractures have a lower body weight compared with controls, and they may also have less soft tissue covering the hip even when adjusted for body mass index, indicating a more android body habitus. Experimental studies show that the passive energy absorption in soft tissue covering the hip may influence the risk of hip fracture, and being an important determinant for the development of hip fracture, maybe more important than bone strength. External hip protectors were developed and tested in an open randomised nursing home study. The rate of hip fractures was reduced by 50%, corresponding to 9 out of 247 residents saved from sustaining a hip fracture. The review points to the essentials of the development of hip fracture, which constitutes; risk of fall, type of fall, type of impact, energy absorption, and lastly bone strength, which is the ultimate and last permissive factor in the cascade leading to hip fracture. Risk estimation and prevention of hip fractures may prove realistic when these issues are taken into consideration.
Engineering of a multi-station shoulder simulator.
Smith, Simon L; Li, Lisa; Joyce, Thomas J
2016-05-01
This work aimed to engineer a multi-station shoulder simulator in order to wear test shoulder prostheses using recognized shoulder activities of daily living. A bespoke simulator was designed, built and subject to commissioning trials before a first wear test was conducted. Five JRI Orthopaedics Reverse Shoulder VAIOS 42 mm prostheses were tested for 2.0 million cycles and a mean wear rate and standard deviation of 14.2 ± 2.1 mm(3)/10(6) cycles measured for the polymeric glenoid components. This result when adjusted for prostheses diameters and test conditions showed excellent agreement with results from hip simulator studies of similar materials in a lubricant of bovine serum. The Newcastle Shoulder Simulator is the first multi-station shoulder simulator capable of applying physiological motion and loading for typical activities of daily living. © IMechE 2016.
Parallel transmission RF pulse design with strict temperature constraints.
Deniz, Cem M; Carluccio, Giuseppe; Collins, Christopher
2017-05-01
RF safety in parallel transmission (pTx) is generally ensured by imposing specific absorption rate (SAR) limits during pTx RF pulse design. There is increasing interest in using temperature to ensure safety in MRI. In this work, we present a local temperature correlation matrix formalism and apply it to impose strict constraints on maximum absolute temperature in pTx RF pulse design for head and hip regions. Electromagnetic field simulations were performed on the head and hip of virtual body models. Temperature correlation matrices were calculated for four different exposure durations ranging between 6 and 24 min using simulated fields and body-specific constants. Parallel transmission RF pulses were designed using either SAR or temperature constraints, and compared with each other and unconstrained RF pulse design in terms of excitation fidelity and safety. The use of temperature correlation matrices resulted in better excitation fidelity compared with the use of SAR in parallel transmission RF pulse design (for the 6 min exposure period, 8.8% versus 21.0% for the head and 28.0% versus 32.2% for the hip region). As RF exposure duration increases (from 6 min to 24 min), the benefit of using temperature correlation matrices on RF pulse design diminishes. However, the safety of the subject is always guaranteed (the maximum temperature was equal to 39°C). This trend was observed in both head and hip regions, where the perfusion rates are very different. Copyright © 2017 John Wiley & Sons, Ltd.
Dragomir-Daescu, Dan; Buijs, Jorn Op Den; McEligot, Sean; Dai, Yifei; Entwistle, Rachel C.; Salas, Christina; Melton, L. Joseph; Bennet, Kevin E.; Khosla, Sundeep; Amin, Shreyasee
2013-01-01
Clinical implementation of quantitative computed tomography-based finite element analysis (QCT/FEA) of proximal femur stiffness and strength to assess the likelihood of proximal femur (hip) fractures requires a unified modeling procedure, consistency in predicting bone mechanical properties, and validation with realistic test data that represent typical hip fractures, specifically, a sideways fall on the hip. We, therefore, used two sets (n = 9, each) of cadaveric femora with bone densities varying from normal to osteoporotic to build, refine, and validate a new class of QCT/FEA models for hip fracture under loading conditions that simulate a sideways fall on the hip. Convergence requirements of finite element models of the first set of femora led to the creation of a new meshing strategy and a robust process to model proximal femur geometry and material properties from QCT images. We used a second set of femora to cross-validate the model parameters derived from the first set. Refined models were validated experimentally by fracturing femora using specially designed fixtures, load cells, and high speed video capture. CT image reconstructions of fractured femora were created to classify the fractures. The predicted stiffness (cross-validation R2 = 0.87), fracture load (cross-validation R2 = 0.85), and fracture patterns (83% agreement) correlated well with experimental data. PMID:21052839
Tateuchi, Hiroshige; Koyama, Yumiko; Akiyama, Haruhiko; Goto, Koji; So, Kazutaka; Kuroda, Yutaka; Ichihashi, Noriaki
2016-09-01
A decline in physical function associated with secondary hip osteoarthritis (OA) may be caused by both radiographic and clinical factors; however, the underlying mechanism remains unclear. The purpose of this study was to determine how joint degeneration, hip morphology, pain, hip range of motion (ROM), and hip muscle strength relate to one-leg standing (OLS) and gait in patients with mild-to-moderate secondary hip osteoarthritis. Fifty-five female patients (ages 22-65 years) with mild-to-moderate hip OA secondary to hip dysplasia were consecutively enrolled. Balance during OLS and three-dimensional hip angle changes while maintaining the OLS and at foot-off of the raised leg were measured. Gait speed and peak three-dimensional hip joint angles during gait were also measured. The associations between dependent variables (balance, gait speed, and hip kinematic changes) and independent variables (age, body mass index, pain, joint degeneration, hip morphologic abnormality, passive hip ROM, and hip muscle strength) were determined. While lower hip muscle strength was associated with hip kinematic changes such as flexion and internal rotation while maintaining OLS, decreased acetabular head index (AHI) and increased pain were associated with hip extension and abduction at foot-off in OLS. Decreased passive hip ROM was associated with decreased peak hip angles (extension, adduction, and external and internal rotation) during gait, although increased pain and decreased hip extension muscle strength were associated with slower gait speed. In this study of patients with secondary hip OA, AHI, pain, and hip impairments were associated with OLS and gait independently from age and radiographic degeneration. Copyright © 2016 Elsevier B.V. All rights reserved.
Davies, J P; Tse, M K; Harris, W H
1996-08-01
Debonding of the cement-metal interface of cemented femoral components of total hip arthroplasty has been shown from clinical and autopsy material to be a common occurrence. Experimentally, debonding has been shown to increase markedly the strains in the adjacent cement mantle. Studies of autopsy-retrieved specimens demonstrate that debonding of the cement-metal interface is a key initiating event in loosening of cemented femoral components of total hip arthroplasty. However, both the radiographic and autopsy evidence of cement-metal interfacial debonding exist after the fact, that is, after debonding has occurred. The lack of prospective data showing that debonding does indeed occur under physiologic loading and occurs prior to other forms of failure of fixation leaves uncertain the issue of debonding and its role in initiating loosening of cemented femoral components. Knowing when, where, and to what extent the cement-metal interface debonds is critical information in understanding the process of loosening of cemented femoral components. Such information would contribute to improving the durability of stems and improving cementing techniques. In this study, the two nondestructive techniques of acoustic emission and ultrasonic evaluation of the cement-metal interface of cemented femoral stems of total hip arthroplasty were combined to investigate when, where, and to what extent cement-metal debonding occurred in vitro in simulated femurs loaded physiologically in fatigue in simulated single-leg stance. Debonding of the cement-metal interface of a cemented femoral component in this model was both an initiating event and a major mechanism of compromise of the cement-metal interface. Additional acoustic emission signals arose from cracks that developed in the cement.
Aulakh, Tajeshwar S; Jayasekera, Narlaka; Singh, Rohit; Patel, Amit; Roulahamin, Nick; Kuiper, Jan H; Richardson, James B
2015-06-01
Metal-on-metal hip resurfacing is undertaken worldwide. This procedure helps preserve femoral bone stock and allows patients to return to high activity sports. Most outcome studies are individual surgeon case series from single centers where the results and outcomes are evaluated by the same surgeon. One method of increasing the external validity of a follow-up study is to have a multi-centre study design with independent assessment of the outcomes. We present an independent assessment of eleven year follow-up of hip resurfacing outcomes from an international hip resurfacing register. The purpose of this study was to assess: Implant survival at maximum follow-up for revision due to any reason, implant survival at maximum follow-up for revision due to major causes of failure, hip function following hip resurfacing and factors affecting hip function, effect of gender and age on hip function and implant survival, effect of femoral component size on hip function and implant survival. 4535 patients (5000 hips) entered into the registry during 1997-2002 were studied. In summary, at a maximum follow-up of 11 years hip resurfacing has a good implant survival of 96.2% and excellent post-operative function. This is excellent given the international and multisurgeon nature of this cohort where majority of the surgeons were in their learning curve.
Mulvaney, Sean W
2009-01-01
Viscosupplementation of the hip for symptomatic osteoarthritis appears to be safe and effective in more than 25 yr of use in Europe. More than 11 studies suggest that viscosupplementation in the hip is as effective as viscosupplementation in the knee. It appears to be a safe and reasonable alternative to nonsteroidal antiinflammatory drugs or intra-articular steroids for the treatment of osteoarthritis pain. Viscosupplementation in the hip may delay the need for hip replacement surgery. Viscosupplementation in the hip appears to work better in patients with fewer radiographic changes of osteoarthritis. Placement of viscosupplement in the hip under real-time ultrasound or fluoroscopic guidance is safe and well tolerated. Hip joint communication with the iliopsoas bursa may be a factor in studies of the effectiveness of viscosupplementation in the hip.
NASA Astrophysics Data System (ADS)
Pancharoen, K.; Zhu, D.; Beeby, S. P.
2016-11-01
This paper presents a magnetically levitated electromagnetic vibration energy harvester based on magnet arrays. It has a nonlinear response that extends the operating bandwidth and enhances the power output of the harvesting device. The harvester is designed to be embedded in a hip prosthesis and harvest energy from low frequency movements (< 5 Hz) associated with human motion. The design optimization is performed using Comsol simulation considering the constraints on size of the harvester and low operating frequency. The output voltage across the optimal load 3.5kΩ generated from hip movement is 0.137 Volts during walking and 0.38 Volts during running. The power output harvested from hip movement during walking and running is 5.35 μW and 41.36 μW respectively..
Prather, Heidi; Cheng, Abby; Steger-May, Karen; Maheshwari, Vaibhav; Van Dillen, Linda
2017-03-01
Study Design Prospective cohort study, cross-sectional design. Background The hip-spine syndrome is described in patients with known arthritis of the hip. This study describes the hip examination findings of people presenting with low back pain (LBP). Objectives To (1) report examination findings of the hip in patients with LBP and (2) compare pain and function in patients with positive hip examination findings to those in patients without positive hip examination findings. Methods An examination and validated questionnaires of spine and hip pain and function were completed. Pain and function scores were compared between patients with and without positive hip findings. Results Consecutive patients (68 women, 33 men) with a mean age of 47.6 years (range, 18.4-79.8 years) participated. On physical examination, 81 (80%) had reduced hip flexion; 76 (75%) had reduced hip internal rotation; and 25 (25%) had 1, 32 (32%) had 2, and 23 (23%) had 3 positive provocative hip tests. Patients with reduced hip flexion had worse LBP-related (mean modified Oswestry Disability Index, 35.3 versus 25.6; P = .04) and hip-related function (mean modified Harris Hip Score, 66.0 versus 82.0; P = .03). Patients with reduced hip internal rotation had worse LBP-related function (mean Roland-Morris questionnaire, 12.4 versus 8.2; P = .003). A positive provocative hip test was coupled with more intense pain (median, 9 versus 7; P = .05) and worse LBP-related (mean Roland-Morris questionnaire, 12.1 versus 8.5; P = .02) and hip-related function (mean modified Harris Hip Score, 65.8 versus 89.7; P = .005). Conclusion Physical examination findings indicating hip dysfunction are common in patients presenting with LBP. Patients with LBP and positive hip examination findings have more pain and worse function compared to patients with LBP but without positive hip examination findings. Level of Evidence Symptom prevalence, level 1b. J Orthop Sports Phys Ther 2017;47(3):163-172. Epub 3 Feb 2017. doi:10.2519/jospt.2017.6567.
Assessment of metal artifact reduction methods in pelvic CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdoli, Mehrsima; Mehranian, Abolfazl; Ailianou, Angeliki
2016-04-15
Purpose: Metal artifact reduction (MAR) produces images with improved quality potentially leading to confident and reliable clinical diagnosis and therapy planning. In this work, the authors evaluate the performance of five MAR techniques for the assessment of computed tomography images of patients with hip prostheses. Methods: Five MAR algorithms were evaluated using simulation and clinical studies. The algorithms included one-dimensional linear interpolation (LI) of the corrupted projection bins in the sinogram, two-dimensional interpolation (2D), a normalized metal artifact reduction (NMAR) technique, a metal deletion technique, and a maximum a posteriori completion (MAPC) approach. The algorithms were applied to ten simulatedmore » datasets as well as 30 clinical studies of patients with metallic hip implants. Qualitative evaluations were performed by two blinded experienced radiologists who ranked overall artifact severity and pelvic organ recognition for each algorithm by assigning scores from zero to five (zero indicating totally obscured organs with no structures identifiable and five indicating recognition with high confidence). Results: Simulation studies revealed that 2D, NMAR, and MAPC techniques performed almost equally well in all regions. LI falls behind the other approaches in terms of reducing dark streaking artifacts as well as preserving unaffected regions (p < 0.05). Visual assessment of clinical datasets revealed the superiority of NMAR and MAPC in the evaluated pelvic organs and in terms of overall image quality. Conclusions: Overall, all methods, except LI, performed equally well in artifact-free regions. Considering both clinical and simulation studies, 2D, NMAR, and MAPC seem to outperform the other techniques.« less
Figueiredo-Pina, C G; Yan, Y; Neville, A; Fisher, J
2008-04-01
Hip simulator studies have been carried out extensively to understand and test artificial hip implants in vitro as an efficient alternative to obtaining long-term results in vivo. Recent studies have shown that a ceramic-on-metal material combination lowers the wear by up to 100 times in comparison with a typical metal-on-metal design. The reason for this reduction remains unclear and for this reason this study has undertaken simple tribometer tests to understand the fundamental material loss mechanisms in two material combinations: metal-on-metal and ceramic-on-ceramic. A simple-configuration reciprocating pin-on-plate wear study was performed under open-circuit potential (OCP) and with applied cathodic protection (CP) in a serum solution using two tribological couples: firstly, cobalt-chromium (Co-Cr) pins against Co-Cr plates; secondly, Co-Cr pins against alumina (Al2O3) plates. The pin and plate surfaces prior to and after testing were examined by profilometry and scanning electron microscopy. The results showed a marked reduction in wear when CP was applied, indicating that total material degradation under the OCP condition was attributed to corrosion processes. The substitution of the Co-Cr pin with an Al2O3 plate also resulted in a dramatic reduction in wear, probably due to the reduction in the corrosion-wear interactions between the tribological pair.
Tijssen, Marsha; van Cingel, Robert; de Visser, Enrico; Nijhuis-van der Sanden, Maria
2016-07-01
To describe data of short- and midterm results of hip arthroscopy patients based on patient-reported hip function, hip functional performance and return to sports activities. Observational cohort study. Sports medical center. 37 recreational athletes (21 men) at least six months after finishing rehabilitation for hip arthroscopy. International Hip Outcome Tool 33 (IHOT-33), Pain Visual Analogue Scale (VAS), Global Perceived Effect Scale (GPE), sports questionnaires and hip functional performance tests. At a mean follow-up time of 2.3 years, 81% of participants reported improvement on the GPE and 84% returned to sports activities. The mean IHOT-33 score was 69.3; the mean VAS score was 35.0. Range of motion (ROM) and strength were within the 90% Limb Symmetry Index (LSI) limit, except for hip internal rotation ROM. A full recovery of hip functional performance, as measured with balance and hop tests, was established based on the 90% LSI limit. The overall short- and midterm results of these follow-up data show good recovery of hip arthroscopy patients on patient-reported outcomes, functional performance and return to sports activities. The functional performance tests used in this study seem adequate for measuring recovery in hip arthroscopy patients. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit
2017-07-01
Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.
Evaluation of factors that affect hip moment impulse during gait: A systematic review.
Inai, Takuma; Takabayashi, Tomoya; Edama, Mutsuaki; Kubo, Masayoshi
2018-03-01
Decreasing the daily cumulative hip moments in the frontal and sagittal planes may lower the risk of hip osteoarthritis. Therefore, it may be important to evaluate factors that affect hip moment impulse during gait. It is unclear what factors affect hip moment impulse during gait. This systematic review aimed to evaluate different factors that affect hip moment impulse during gait in healthy adults and patients with hip osteoarthritis. Four databases (Scopus, ScienceDirect, PubMed, and PEDro) were searched up to August 2017 to identify studies that examined hip moment impulse during gait. Data extracted for analysis included the sample size, age, height, body mass, type of intervention, and main findings. After screening, 10 of the 975 studies identified were included in our analysis. Several factors, including a rocker bottom shoe, FitFlop™ sandals, ankle push-off, posture, stride length, body-weight unloading, a rollator, walking poles, and a knee brace, were reviewed. The main findings were as follows: increasing ankle push-off decreased both the hip flexion and extension moment impulses; body-weight unloading decreased both the hip extension and adduction moment impulses; the FitFlop™ sandal increased the sum of the hip flexion and extension moment impulses; long strides increased the hip extension moment impulse; and the use of a knee brace increased hip flexion moment impulse. Of note, none of the eligible studies included patients with hip osteoarthritis. The hip moment impulses can be modified by person-specific factors (ankle push-off and long strides) and external factors (body-weight unloading and use of the FitFlop™ sandals and a knee brace). Effects on the progression of hip osteoarthritis remain to be evaluated. Copyright © 2018 Elsevier B.V. All rights reserved.
Kim, Si-hyun; Kwon, Oh-yun; Yi, Chung-hwi; Cynn, Heon-seock; Ha, Sung-min; Park, Kyue-nam
2014-01-01
Limited hip flexion may lead to a poor lumbopelvic motion during seated active hip flexion in people with low-back pain (LBP). The purpose of this study was to compare lumbopelvic motion during seated hip flexion between subjects with and without LBP accompanying limited hip flexion. Fifteen patients with LBP accompanying limited hip flexion and 16 healthy subjects were recruited. The subjects performed seated hip flexion with the dominant leg three times. A three-dimensional motion-analysis system was used to measure lumbopelvic motion during seated hip flexion. During seated active hip flexion, the angle of hip flexion was significantly lower in patients with LBP accompanying limited hip flexion (17.4 ± 4.4 in the LBP group, 20.8 ± 2.6 in the healthy group; t = 2.63, p = 0.014). The angle of the lumbar flexion (4.8 ± 2.2 in the LBP group, 2.6 ± 2.0 in the healthy group; t = -2.96, p = 0.006) and posterior pelvic tilting (5.0 ± 2.6 in the LBP group, 2.9 ± 2.0 in the healthy group; t = 2.48 p = 0.019), however, were significantly greater in patients with this condition. The results of this study suggest that limited hip flexion in LBP can contribute to excessive lumbar flexion and posterior pelvic tilting during hip flexion in the sitting position. Further studies are required to confirm whether improving the hip flexion range of motion can reduce excessive lumbar flexion in patients with LBP accompanying limited hip flexion.
Tribological characteristics of a composite total-surface hip replacement
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Roberts, J. C.; Ling, F. F.
1982-01-01
Continuous fiber, woven E glass composite femoral shells having the same elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle wear tests on a total hip simulator. The tribological characteristics of these continuous fiber particulate composite femoral shells articulating with ultrahigh molecular weight polyethylene acetabular cups were comparable to those of a vitallium ball articulating with an ultrahigh molecular weight polyethylene acetabular cup.
Work Plan for an Inpatient Rehabilitation Prospective Payment System
2000-01-01
through 4.23 5 Nontraumatic spinal cord 4.1,4.11 through 4.13 6 Neurological 3.1,3.2,3.3,3.5,3.8,3.9 7 Hip fracture 8.11 through 8.4 8 Replacement of...Eilertsen, C. A. Hrincevich, D. A. Tropea, L. A. Ahmad, and D. G. Eckhoff, "Outcomes and Costs After Hip Fracture and Stroke: A Comparison of...Teaching Costs 53 Low Income Patients 55 Other Factors Affecting Cost 58 Multivariate Regression Analysis 59 8. SIMULATIONS AND IMPACT ANALYSES 60 Data
Roy, Sandipan; Panda, Debojyoti; Khutia, Niloy; Chowdhury, Amit Roy
2014-01-01
The present study investigates the mechanical response of representative volume elements of porous Ti-6Al-4V alloy, to arrive at a desired range of pore geometries that would optimize the reduction in stiffness necessary for biocompatibility with the stress concentration arising around the pore periphery, under physiological loading conditions with respect to orthopedic hip implants. A comparative study of the two is performed with the aid of a newly defined optimizing parameter called pore efficiency that takes into consideration both the stiffness quantity and the stress localization around pores. To perform a detailed analysis of the response of the porous structure over the entire spectrum of loading conditions that a hip implant is subjected to in vivo, the mechanical responses of 3D finite element models of cubic and rectangular parallelepiped geometries, with porosities varying over a range of 10% to 60%, are simulated under representative compressive, flexural as well as combined loading conditions. The results that are obtained are used to suggest a range of pore diameters that lower the effective stiffness and modulus of the implant to around 60% of the stiffness and modulus of dense solid implants while keeping the stress levels within permissible limits. PMID:25400663
Lower Extremity Kinematics Differed Between a Controlled Drop-Jump and Volleyball-Takeoffs.
Beardt, Bradley S; McCollum, Myranda R; Hinshaw, Taylour J; Layer, Jacob S; Wilson, Margaret A; Zhu, Qin; Dai, Boyi
2018-04-03
Previous studies utilizing jump-landing biomechanics to predict anterior cruciate ligament injuries have shown inconsistent findings. The purpose of this study was to quantify the differences and correlations in jump-landing kinematics between a drop-jump, a controlled volleyball-takeoff, and a simulated-game volleyball-takeoff. Seventeen female volleyball players performed these three tasks on a volleyball court while three-dimensional kinematic data were collected by three calibrated camcorders. Participants demonstrated significantly increased jump height, shorter stance time, increased time differences in initial contact between two feet, increased knee and hip flexion at initial contact and decreased peak knee and hip flexion for both left and right legs, and decreased knee-ankle distance ratio at the lowest height of mid-hip for the two volleyball-takeoffs compared with the drop-jump (p < 0.05, Cohen's dz ≥ 0.8). Significant correlations were observed for all variables between the two volleyball-takeoffs (p < 0.05, ρ ≥ 0.6), but were not for most variables between the drop-jump and two volleyball-takeoffs. Controlled drop-jump kinematics may not represent jump-landing kinematics exhibited during volleyball competition. Jump-landing mechanics during sports-specific tasks may better represent those exhibited during sports competition and their associated risk of ACL injury compared with the drop-jump.
Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E
2014-10-01
The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if cups are oriented at more than 40° of abduction.
The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study.
Bhashyam, Abhiram R; Rodriguez, Edward K; Appleton, Paul; Wixted, John J
2018-04-03
The femoral neck-shaft angle (NSA) is used to restore normal hip geometry during hip fracture repair. Femoral rotation is known to affect NSA measurement, but the effect of hip flexion-extension is unknown. The goals of this study were to determine and test mathematical models of the relationship between hip flexion-extension, femoral rotation and NSA. We hypothesized that hip flexion-extension and femoral rotation would result in NSA measurement error. Two mathematical models were developed to predict NSA in varying degrees of hip flexion-extension and femoral rotation. The predictions of the equations were tested in vitro using a model that varied hip flexion-extension while keeping rotation constant, and vice versa. The NSA was measured from an AP radiograph obtained with a C-arm. Attributable measurement error based on hip positioning was calculated from the models. The predictions of the model correlated well with the experimental data (correlation coefficient = 0.82 - 0.90). A wide range of patient positioning was found to result in less than 5-10 degree error in the measurement of NSA. Hip flexion-extension and femoral rotation had a synergistic effect in measurement error of the NSA. Measurement error was minimized when hip flexion-extension was within 10 degrees of neutral. This study demonstrates that hip flexion-extension and femoral rotation significantly affect the measurement of the NSA. To avoid inadvertently fixing the proximal femur in varus or valgus, the hip should be positioned within 10 degrees of neutral flexion-extension with respect to the C-arm to minimize positional measurement error. N/A, basic science study.
Dobashi, Kazushige; Takahashi, Kenichiro; Nagahara, Keiko; Tanaka, Daisuke; Itabashi, Kazuo
2017-01-01
To investigate whether body adiposity index (BAI; hip/height 1.5 -18), pediatric BAI (BAIp; hip/height 0.8 - 38), and other hip/height P ratios are useful in obese children. Ninety obese Japanese children, 55 boys and 35 girls, who visited our University Clinic, were enrolled. The age was 9.92±2.6 (mean±SD) years, and the percentage overweight (POW) was 51.6±18.8%. We set the power value of the hip/height P 0, 0.5, 0.8, 1, 1.5, and 2 and studied the association with overweight indices, biochemical data, and fat area measured by computed tomography. Waist, waist/height ratio, and waist/hip ratio were also evaluated. Hip/height and hip/height 0.8 (BAIp) were more closely correlated with POW, body mass index percentile, and percentage body fat than hip/height 1.5 (BAI). The correlation coefficient of hip/height with POW (r =0.855) was the highest among the studied hip/height P indices. The approximate line to predict POW was 411×hip/height-207. The waist/height was also highly correlated with POW (r=0.879). Hip and hip/height 0.5 were more closely correlated with visceral fat area than hip/height, BAIp, and hip/height 1.5 . Hip and hip/height 0.5 were significantly correlated with insulin. Only hip was also significantly associated with dyslipidemia. All hip/height P indices were not significantly correlated with alanine aminotransferase (ALT). Waist was significantly correlated with serum lipids, ALT, and insulin. Hip/height and BAIp are better markers for overweight (adiposity) in obese children than BAI. However, hip/height, BAIp, and BAI are not useful to predict metabolic complications. Waist appears to be the best index for obese children overall at this time.
Diabetes mellitus and risk of hip fractures: a meta-analysis.
Fan, Y; Wei, F; Lang, Y; Liu, Y
2016-01-01
This meta-analysis revealed that diabetic adults had a twofold greater risk of hip fractures compared with non-diabetic populations, and this association was more pronounced in type 1 diabetes. The relationship between diabetes mellitus and risk of hip fracture yielded conflicting results. We conducted a meta-analysis to investigate the association between diabetes mellitus and the risk of hip fractures based on observational studies. We conducted a systematic literature search of PubMed and Embase databases through May 2015. We selected cohort and case-control studies providing at least age-adjusted risk ratio (RR) and corresponding 95 % confidence intervals (CI) of hip fractures among diabetic and non-diabetic subjects. Moreover, we pooled the female-to-male RR of hip fractures from studies that reported gender-specific risk estimate in a single study. Twenty-one studies involving 82,293 hip fracture events among 6,995,272 participants were identified. Diabetes mellitus was associated with an increased risk of hip fractures (RR 2.07; 95 % CI 1.83-2.33) in a random effects model. Subgroup analysis indicated that excess risk of hip fracture was more pronounced in type 1 diabetes (RR 5.76; 95 % CI 3.66-9.07) than that in type 2 diabetes (RR 1.34; 95 % CI 1.19-1.51). The pooled female-to-male RR of hip fractures was 1.09 (95 % CI 0.93-1.28). Individuals with diabetes mellitus have an excessive risk of hip fractures, and this relationship is more pronounced in type 1 diabetes. The association between diabetes and hip fracture risk is similar in men and women.
John, Dinesh; Morton, Alvin; Arguello, Diego; Lyden, Kate; Bassett, David
2018-04-15
(1) Background: This study compared manually-counted treadmill walking steps from the hip-worn DigiwalkerSW200 and OmronHJ720ITC, and hip and wrist-worn ActiGraph GT3X+ and GT9X; determined brand-specific acceleration amplitude (g) and/or frequency (Hz) step-detection thresholds; and quantified key features of the acceleration signal during walking. (2) Methods: Twenty participants (Age: 26.7 ± 4.9 years) performed treadmill walking between 0.89-to-1.79 m/s (2-4 mph) while wearing a hip-worn DigiwalkerSW200, OmronHJ720ITC, GT3X+ and GT9X, and a wrist-worn GT3X+ and GT9X. A DigiwalkerSW200 and OmronHJ720ITC underwent shaker testing to determine device-specific frequency and amplitude step-detection thresholds. Simulated signal testing was used to determine thresholds for the ActiGraph step algorithm. Steps during human testing were compared using bias and confidence intervals. (3) Results: The OmronHJ720ITC was most accurate during treadmill walking. Hip and wrist-worn ActiGraph outputs were significantly different from the criterion. The DigiwalkerSW200 records steps for movements with a total acceleration of ≥1.21 g. The OmronHJ720ITC detects a step when movement has an acceleration ≥0.10 g with a dominant frequency of ≥1 Hz. The step-threshold for the ActiLife algorithm is variable based on signal frequency. Acceleration signals at the hip and wrist have distinctive patterns during treadmill walking. (4) Conclusions: Three common research-grade physical activity monitors employ different step-detection strategies, which causes variability in step output.
John, Dinesh; Arguello, Diego; Lyden, Kate; Bassett, David
2018-01-01
(1) Background: This study compared manually-counted treadmill walking steps from the hip-worn DigiwalkerSW200 and OmronHJ720ITC, and hip and wrist-worn ActiGraph GT3X+ and GT9X; determined brand-specific acceleration amplitude (g) and/or frequency (Hz) step-detection thresholds; and quantified key features of the acceleration signal during walking. (2) Methods: Twenty participants (Age: 26.7 ± 4.9 years) performed treadmill walking between 0.89-to-1.79 m/s (2–4 mph) while wearing a hip-worn DigiwalkerSW200, OmronHJ720ITC, GT3X+ and GT9X, and a wrist-worn GT3X+ and GT9X. A DigiwalkerSW200 and OmronHJ720ITC underwent shaker testing to determine device-specific frequency and amplitude step-detection thresholds. Simulated signal testing was used to determine thresholds for the ActiGraph step algorithm. Steps during human testing were compared using bias and confidence intervals. (3) Results: The OmronHJ720ITC was most accurate during treadmill walking. Hip and wrist-worn ActiGraph outputs were significantly different from the criterion. The DigiwalkerSW200 records steps for movements with a total acceleration of ≥1.21 g. The OmronHJ720ITC detects a step when movement has an acceleration ≥0.10 g with a dominant frequency of ≥1 Hz. The step-threshold for the ActiLife algorithm is variable based on signal frequency. Acceleration signals at the hip and wrist have distinctive patterns during treadmill walking. (4) Conclusions: Three common research-grade physical activity monitors employ different step-detection strategies, which causes variability in step output. PMID:29662048
Model for Predicting the Performance of Planetary Suit Hip Bearing Designs
NASA Technical Reports Server (NTRS)
Cowley, Matthew S.; Margerum, Sarah; Hharvill, Lauren; Rajulu, Sudhakar
2012-01-01
Designing a space suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. During the development period of the suit numerous design iterations need to occur before the hardware meets human performance requirements. Using computer models early in the design phase of hardware development is advantageous, by allowing virtual prototyping to take place. A virtual design environment allows designers to think creatively, exhaust design possibilities, and study design impacts on suit and human performance. A model of the rigid components of the Mark III Technology Demonstrator Suit (planetary-type space suit) and a human manikin were created and tested in a virtual environment. The performance of the Mark III hip bearing model was first developed and evaluated virtually by comparing the differences in mobility performance between the nominal bearing configurations and modified bearing configurations. Suited human performance was then simulated with the model and compared to actual suited human performance data using the same bearing configurations. The Mark III hip bearing model was able to visually represent complex bearing rotations and the theoretical volumetric ranges of motion in three dimensions. The model was also able to predict suited human hip flexion and abduction maximums to within 10% of the actual suited human subject data, except for one modified bearing condition in hip flexion which was off by 24%. Differences between the model predictions and the human subject performance data were attributed to the lack of joint moment limits in the model, human subject fitting issues, and the limited suit experience of some of the subjects. The results demonstrate that modeling space suit rigid segments is a feasible design tool for evaluating and optimizing suited human performance. Keywords: space suit, design, modeling, performance
Development and verification of a cementless novel tapered wedge stem for total hip arthroplasty.
Faizan, Ahmad; Wuestemann, Thies; Nevelos, Jim; Bastian, Adam C; Collopy, Dermot
2015-02-01
Most current tapered wedge hip stems were designed based upon the original Mueller straight stem design introduced in 1977. These stems were designed to have a single medial curvature and grew laterally to accommodate different sizes. In this preclinical study, the design and verification of a tapered wedge stem using computed tomography scans of 556 patients are presented. The computer simulation demonstrated that the novel stem, designed for proximal engagement, allowed for reduced distal fixation, particularly in the 40-60 year male population. Moreover, the physical micromotion testing and finite element analysis demonstrated that the novel stem allowed for reduced micromotion. In summary, preclinical data suggest that the computed tomography based stem design described here may offer enhanced implant fit and reduced micromotion. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Xicheng; Gao, Jiaobo; Wu, Jianghui; Li, Jianjun; Cheng, Hongliang
2017-02-01
Recently, hyperspectral image projectors (HIP) have been developed in the field of remote sensing. For the advanced performance of system-level validation, target detection and hyperspectral image calibration, HIP has great possibility of development in military, medicine, commercial and so on. HIP is based on the digital micro-mirror device (DMD) and projection technology, which is capable to project arbitrary programmable spectra (controlled by PC) into the each pixel of the IUT1 (instrument under test), such that the projected image could simulate realistic scenes that hyperspectral image could be measured during its use and enable system-level performance testing and validation. In this paper, we built a visible hyperspectral image projector also called the visible target simulator with double DMDs, which the first DMD is used to product the selected monochromatic light from the wavelength of 410 to 720 um, and the light come to the other one. Then we use computer to load image of realistic scenes to the second DMD, so that the target condition and background could be project by the second DMD with the selected monochromatic light. The target condition can be simulated and the experiment could be controlled and repeated in the lab, making the detector instrument could be tested in the lab. For the moment, we make the focus on the spectral engine design include the optical system, research of DMD programmable spectrum and the spectral resolution of the selected spectrum. The detail is shown.
Evaluation of graphic cardiovascular display in a high-fidelity simulator.
Agutter, James; Drews, Frank; Syroid, Noah; Westneskow, Dwayne; Albert, Rob; Strayer, David; Bermudez, Julio; Weinger, Matthew B
2003-11-01
"Human error" in anesthesia can be attributed to misleading information from patient monitors or to the physician's failure to recognize a pattern. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. We designed a graphic display to show hemodynamic variables. Twenty anesthesiologists were asked to assume care of a simulated patient. Half the participants used the graphic cardiovascular display; the other half used a Datex As/3 monitor. One scenario was a total hip replacement with a transfusion reaction to mismatched blood. The second scenario was a radical prostatectomy with 1.5 L of blood loss and myocardial ischemia. Subjects who used the graphic display detected myocardial ischemia 2 min sooner than those who did not use the display. Treatment was initiated sooner (2.5 versus 4.9 min). There were no significant differences between groups in the hip replacement scenario. Systolic blood pressure deviated less from baseline, central venous pressure was closer to its baseline, and arterial oxygen saturation was higher at the end of the case when the graphic display was used. The study lends some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnose, manage, and treat critical cardiovascular events in a simulated environment. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. A user-centered design process led to a novel object-oriented graphic display of hemodynamic variables containing emergent features and functional relationships. In a simulated environment, this display appeared to support clinicians' ability to diagnose, manage, and treat a critical cardiovascular event in a simulated environment. We designed a graphic display to show hemodynamic variables. The study provides some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnosis, mange, and treat critical cardiovascular events in a simulated environment.
Clinical study on the unloading effect of hip bracing on gait in patients with hip osteoarthritis.
Nérot, Agathe; Nicholls, Micah
2017-04-01
Internal hip abduction moment is a major indicator for hip loading. A new hip bracing concept was designed to unload the cartilaginous area in hip osteoarthritis via an abduction and external rotation force intended to alter the weight bearing area and reduce compression through the joint. To assess the effect of a novel brace on hip rotation in the transverse and coronal planes and on the hip abduction moment. Repeated measures. Gait analysis was performed on 14 subjects with unilateral symptomatic hip osteoarthritis. Pain, joint motion, moments and vertical ground reaction force were compared between the braced and the unbraced (control), randomly assigned, conditions. Nine participants felt an immediate reduction in pain while walking with the hip brace. Peak hip abduction moment significantly decreased on the osteoarthritis side ( p = 0.017). Peak hip adduction ( p = 0.004) and internal rotation ( p = 0.0007) angles significantly decreased at stance with the brace. Wearing the brace would appear to reduce the compressive joint reaction force at the femuroacetabular interface as indicated by a reduction in internal hip abduction moment along with immediate pain reduction in nine participants. Further long-term studies are warranted. Clinical relevance The brace rotates the hip in the transverse and coronal planes, possibly resulting in a decrease in load through the diseased area of cartilage. In some patients, an immediate decrease in pain was experienced. The brace offers an alternative solution for hip osteoarthritis patients not ready for a hip replacement.
Hussain, Shahid; Jamwal, Prashant K; Ghayesh, Mergen H
2017-05-01
While body weight support (BWS) intonation is vital during conventional gait training of neurologically challenged subjects, it is important to evaluate its effect during robot assisted gait training. In the present research we have studied the effect of BWS intonation on muscle activities during robotic gait training using dynamic simulations. Two dimensional (2-D) musculoskeletal model of human gait was developed conjointly with another 2-D model of a robotic orthosis capable of actuating hip, knee and ankle joints simultaneously. The musculoskeletal model consists of eight major muscle groups namely; soleus (SOL), gastrocnemius (GAS), tibialis anterior (TA), hamstrings (HAM), vasti (VAS), gluteus maximus (GLU), uniarticular hip flexors (iliopsoas, IP), and Rectus Femoris (RF). BWS was provided at levels of 0, 20, 40 and 60% during the simulations. In order to obtain a feasible set of muscle activities during subsequent gait cycles, an inverse dynamics algorithm along with a quadratic minimization algorithm was implemented. The dynamic parameters of the robot assisted human gait such as joint angle trajectories, ground contact force (GCF), human limb joint torques and robot induced torques at different levels of BWS were derived. The patterns of muscle activities at variable BWS were derived and analysed. For most part of the gait cycle (GC) the muscle activation patterns are quite similar for all levels of BWS as is apparent from the mean of muscle activities for the complete GC. Effect of BWS variation during robot assisted gait on muscle activities was studied by developing dynamic simulation. It is expected that the proposed dynamic simulation approach will provide important inferences and information about the muscle function variations consequent upon a change in BWS during robot assisted gait. This information shall be quite important while investigating the influence of BWS intonation on neuromuscular parameters of interest during robotic gait training.
Muscle strength and areal bone mineral density at the hip in women: a cross-sectional study.
Pasco, Julie A; Holloway, Kara L; Brennan-Olsen, Sharon L; Moloney, David J; Kotowicz, Mark A
2015-05-24
Muscle strengthening exercises are promoted for building and maintaining a healthy skeleton. We aimed to investigate the relationship between muscle strength and areal bone mineral density (BMD) at the hip in women aged 26-97 years. This cross-sectional study utilises data from 863 women assessed for the Geelong Osteoporosis Study. Measures of hip flexor and abductor strength were made using a hand-held dynamometer (Nicholas Manual Muscle Tester). The maximal measure from three trials on each leg was used for analyses. BMD was measured at the hip using dual energy x-ray absorptiometry (DXA; Lunar DPX-L). Total lean mass, body fat mass and appendicular lean mass were determined from whole body DXA scans. Linear regression techniques were used with muscle strength as the independent variable and BMD as the dependent variable. Models were adjusted for age and indices of body composition. Measures of age-adjusted hip flexor strength and hip abductor strength were positively associated with total hip BMD. For each standard deviation (SD) increase in hip flexor strength, the increase in mean total hip BMD (SD) was 10.4 % (p = 0.009). A similar pattern was observed for hip abductor strength, with an increase in mean total hip BMD of 22.8 % (p = 0.025). All associations between hip muscle strength and total hip BMD were independent of height, but were nullified after adjusting for appendicular lean mass or total lean mass. There was a positive association observed between muscle strength and BMD at the hip. However, this association was explained by measures of lean mass.
From "They" Science to "Our" Science: Hip Hop Epistemology in STEAM Education
NASA Astrophysics Data System (ADS)
Dolberry, Maurice E.
Hip hop has moved from being considered a type of music into being understood as a culture in which a prominent type of music originates. Hip hop culture has a philosophy and epistemological constructs as well. This study analyzed those constructs to determine how conceptions of science factor in hip hop worldviews. Pedagogical models in culturally responsive teaching and Science, Technology, Engineering, Arts, and Mathematics (STEAM) education were also examined to discern their philosophical connections with hip hop culture. These connections were used to create two theoretical models. The first one, Hip Hop Science, described how scientific thought functions in hip hop culture. The second model, Hip Hop STEAM Pedagogy, proposes how hip hop culture can inform STEAM teaching practices. The study began by using Critical Race Theory to create a theoretical framework proposing how the two theoretical models could be derived from the philosophical and pedagogical concepts. Content analysis and narrative inquiry were used to analyze data collected from scholarly texts, hip hop songs, and interviews with hip hop-responsive educators. The data from these sources were used initially to assess the adequacy of the proposed theoretical framework, and subsequently to improve its viability. Four overlapping themes emerged from the data analyses, including hip hop-resistance to formal education; how hip hop culture informs pedagogical practice in hip hop-responsive classrooms; conceptions of knowledge and reality that shape how hip hoppers conduct scientific inquiry; and hip hop-based philosophies of effective teaching for hip hoppers as a marginalized cultural group. The findings indicate that there are unique connections between hip hop epistemology, sciencemindedness, and pedagogical practices in STEAM education. The revised theoretical framework clarified the nature of these connections, and supported claims from prior research that hip hop culture provides viable sites of engagement for STEAM educators. It concluded with suggestions for future research that further explicates hip hop epistemology and Hip Hop STEAM Pedagogy.
A cardioid oscillator with asymmetric time ratio for establishing CPG models.
Fu, Q; Wang, D H; Xu, L; Yuan, G
2018-01-13
Nonlinear oscillators are usually utilized by bionic scientists for establishing central pattern generator models for imitating rhythmic motions by bionic scientists. In the natural word, many rhythmic motions possess asymmetric time ratios, which means that the forward and the backward motions of an oscillating process sustain different times within one period. In order to model rhythmic motions with asymmetric time ratios, nonlinear oscillators with asymmetric forward and backward trajectories within one period should be studied. In this paper, based on the property of the invariant set, a method to design the closed curve in the phase plane of a dynamic system as its limit cycle is proposed. Utilizing the proposed method and considering that a cardioid curve is a kind of asymmetrical closed curves, a cardioid oscillator with asymmetric time ratios is proposed and realized. Through making the derivation of the closed curve in the phase plane of a dynamic system equal to zero, the closed curve is designed as its limit cycle. Utilizing the proposed limit cycle design method and according to the global invariant set theory, a cardioid oscillator applying a cardioid curve as its limit cycle is achieved. On these bases, the numerical simulations are conducted for analyzing the behaviors of the cardioid oscillator. The example utilizing the established cardioid oscillator to simulate rhythmic motions of the hip joint of a human body in the sagittal plane is presented. The results of the numerical simulations indicate that, whatever the initial condition is and without any outside input, the proposed cardioid oscillator possesses the following properties: (1) The proposed cardioid oscillator is able to generate a series of periodic and anti-interference self-exciting trajectories, (2) the generated trajectories possess an asymmetric time ratio, and (3) the time ratio can be regulated by adjusting the oscillator's parameters. Furthermore, the comparison between the simulated trajectories by the established cardioid oscillator and the measured angle trajectories of the hip angle of a human body show that the proposed cardioid oscillator is fit for imitating the rhythmic motions of the hip of a human body with asymmetric time ratios.
Development of a hip joint model for finite volume simulations.
Cardiff, P; Karač, A; FitzPatrick, D; Ivanković, A
2014-01-01
This paper establishes a procedure for numerical analysis of a hip joint using the finite volume method. Patient-specific hip joint geometry is segmented directly from computed tomography and magnetic resonance imaging datasets and the resulting bone surfaces are processed into a form suitable for volume meshing. A high resolution continuum tetrahedral mesh has been generated, where a sandwich model approach is adopted; the bones are represented as a stiffer cortical shells surrounding more flexible cancellous cores. Cartilage is included as a uniform thickness extruded layer and the effect of layer thickness is investigated. To realistically position the bones, gait analysis has been performed giving the 3D positions of the bones for the full gait cycle. Three phases of the gait cycle are examined using a finite volume based custom structural contact solver implemented in open-source software OpenFOAM.
Shoulder and Lower Back Joint Reaction Forces in Seated Double Poling.
Lund Ohlsson, Marie; Danvind, Jonas; Holmberg, L Joakim
2018-04-13
Overuse injuries in the shoulders and lower back are hypothesized to be common in cross-country sit-skiing. Athletes with reduced trunk muscle control mainly sits with their knees higher than hips (KH). To reduce spinal flexion, a position with the knees below the hips (KL) was enabled for these athletes using a frontal trunk support. The aim of the study was to compare the shoulder joint (glenohumeral joint) and L4-L5 joint reactions between the sitting positions KL and KH. Five able-bodied female athletes performed submaximal and maximal exercise tests in the sitting positions KL and KH on a ski-ergometer. Measured pole forces and 3-dimensional kinematics served as input for inverse-dynamics simulations to compute the muscle forces and joint reactions in the shoulder and L4-L5 joint. This was the first musculoskeletal simulation study of seated double poling. The results showed that the KH position was favorable for higher performance and decreased values of the shoulder joint reactions for female able-bodied athletes with full trunk control. The KL position was favorable for lower L4-L5 joint reactions and might therefore reduce the risk of lower back injuries. These results indicate that it is hard to optimize both performance and safety in the same sit-ski.
Rankin, Jeffery W; Rubenson, Jonas; Hutchinson, John R
2016-05-01
Owing to their cursorial background, ostriches (Struthio camelus) walk and run with high metabolic economy, can reach very fast running speeds and quickly execute cutting manoeuvres. These capabilities are believed to be a result of their ability to coordinate muscles to take advantage of specialized passive limb structures. This study aimed to infer the functional roles of ostrich pelvic limb muscles during gait. Existing gait data were combined with a newly developed musculoskeletal model to generate simulations of ostrich walking and running that predict muscle excitations, force and mechanical work. Consistent with previous avian electromyography studies, predicted excitation patterns showed that individual muscles tended to be excited primarily during only stance or swing. Work and force estimates show that ostrich gaits are partially hip-driven with the bi-articular hip-knee muscles driving stance mechanics. Conversely, the knee extensors acted as brakes, absorbing energy. The digital extensors generated large amounts of both negative and positive mechanical work, with increased magnitudes during running, providing further evidence that ostriches make extensive use of tendinous elastic energy storage to improve economy. The simulations also highlight the need to carefully consider non-muscular soft tissues that may play a role in ostrich gait. © 2016 The Authors.
Bradley, Sarah V; Hyun, Teresa S; Oravecz-Wilson, Katherine I; Li, Lina; Waldorff, Erik I; Ermilov, Alexander N; Goldstein, Steven A; Zhang, Claire X; Drubin, David G; Varela, Kate; Parlow, Al; Dlugosz, Andrzej A; Ross, Theodora S
2007-06-01
The members of the huntingtin-interacting protein-1 (HIP1) family, HIP1 and HIP1-related (HIP1r), are multi-domain proteins that interact with inositol lipids, clathrin and actin. HIP1 is over-expressed in a variety of cancers and both HIP1 and HIP1r prolong the half-life of multiple growth factor receptors. To better understand the physiological importance of the HIP1 family in vivo, we have analyzed a large cohort of double Hip1/Hip1r knockout (DKO) mice. All DKO mice were dwarfed, afflicted with severe vertebral defects and died in early adulthood. These phenotypes were not observed during early adulthood in the single Hip1 or Hip1r knockouts, indicating that HIP1 and HIP1r compensate for one another. Despite the ability of HIP1 and HIP1r to modulate growth factor receptor levels when over-expressed, studies herein using DKO fibroblasts indicate that the HIP1 family is not necessary for endocytosis but is necessary for the maintenance of diverse adult tissues in vivo. To test if human HIP1 can function similar to mouse HIP1, transgenic mice with 'ubiquitous' expression of the human HIP1 cDNA were generated and crossed with DKO mice. Strikingly, the compound human HIP1 transgenic DKO mice were completely free from dwarfism and spinal defects. This successful rescue demonstrates that the human HIP1 protein shares some interchangeable functions with both HIP1 and HIP1r in vivo. In addition, we conclude that the degenerative phenotypes seen in the DKO mice are due mainly to HIP1 and HIP1r protein deficiency rather than altered expression of neighboring genes or disrupted intronic elements.
Chen, I-J; Chiang, C-Y F; Li, Y-H; Chang, C-H; Hu, C-C; Chen, D W; Chang, Y; Yang, W-E; Shih, H-N; Ueng, S W-N; Hsieh, P-H
2015-02-01
A growing elderly population is expected worldwide, and the burden of hip fractures on health care system will continue to increase. By 2035, there will be a 2.7-fold increase in the number of hip fractures in Taiwan. The study provides quantitative basis for the future distribution of medical resources. Hip fractures have long been recognized as a major public health concern. The study aimed to determine time trends in the incidence of hip fractures and to forecast the number of hip fractures expected in Taiwan up to 2035. A nationwide survey was conducted using data from the Taiwan National Health Insurance Research Database from 2004 to 2011. A total of 141,397 hip fractures were identified, with a mean of 17,675 fractures/year. Annual incidences of hip fractures were calculated and tested for trends. Projections of the incidence rates of hip fractures and bed days associated with hip fractures were calculated using Poisson regression on the historical incidence rates in combination with population projections from 2012 to 2035. The incidence rates of hip fracture during 2004-2011 were 317 and 211 per 100,000 person-years among women and men, respectively. Over this 8-year period, the age-standardized incidence of hip fracture decreased by 13.4% among women and 12.2% among men. Despite the decline in the age-standardized incidence, the absolute number of hip fractures increased owing to the aging population. The number of hip fractures is expected to increase from 18,338 in 2010 to 50,421 in 2035-a 2.7-fold increase. The number of bed days for 2010 and 2035 was estimated at 161,248 and 501,995, respectively, representing a 3.1-fold increase. The socioeconomic impact of hip fractures will be high in the near future. This study provides a quantitative basis for future policy decisions to serve this need.
A Review of Hip Hop-Based Interventions for Health Literacy, Health Behaviors, and Mental Health.
Robinson, Cendrine; Seaman, Elizabeth L; Montgomery, LaTrice; Winfrey, Adia
2018-06-01
African-American children and adolescents experience an undue burden of disease for many health outcomes compared to their White peers. More research needs to be completed for this priority population to improve their health outcomes and ameliorate health disparities. Integrating hip hop music or hip hop dance into interventions may help engage African-American youth in health interventions and improve their health outcomes. We conducted a review of the literature to characterize hip hop interventions and determine their potential to improve health. We searched Web of Science, Scopus, PsycINFO, and EMBASE to identify studies that assessed hip hop interventions. To be included, studies had to (1) be focused on a psychosocial or physical health intervention that included hip hop and (2) present quantitative data assessing intervention outcomes. Twenty-three articles were identified as meeting all inclusion criteria and were coded by two reviewers. Articles were assessed with regards to sample characteristics, study design, analysis, intervention components, and results. Hip hop interventions have been developed to improve health literacy, health behavior, and mental health. The interventions were primarily targeted to African-American and Latino children and adolescents. Many of the health literacy and mental health studies used non-experimental study designs. Among the 12 (of 14) health behavior studies that used experimental designs, the association between hip hop interventions and positive health outcomes was inconsistent. The number of experimental hip hop intervention studies is limited. Future research is required to determine if hip hop interventions can promote health.
Jo, Suenghwan; Lee, Sang Hong; Wang, Sung Il; Smith, Bjorn; O’Donnell, John
2016-01-01
Acetabular dysplasia is one of the most common sources of hip arthritis. With the recent innovation in hip arthroscopy, the question has been raised whether arthroscopy can be used to treat dysplastic hip conditions. The purposes of this systematic review are (i) describe the prevalence of intra-articular pathologies and (ii) report the outcomes of dysplastic hip treatment with hip arthroscopy as a sole treatment. Medical databases were searched for articles including arthroscopic findings and treatment of dysplastic hip with predetermined criteria. PubMed, Ovid database and CINAHL (Cumulative Index to Nursing and Allied Health Literature) were searched up until 7 January 2015. Two reviewers independently assess the eligibility of retrieved studies using titles, abstracts and full-text articles. Thirteen studies were eligible to be included for the systematic review. Overall, labral tear was the most common pathology with a prevalence rate of 77.3%. All of the four studies describing arthroscopic treatment for only borderline dysplasia reported favorable outcome. With regard to more severely dysplastic hips, two out of three studies reported acceptable outcomes while one study reported negative results. This review indicates that intra-articular pathology is commonly observed in symptomatic dysplastic hips with a labral tear being the most common pathology. Arthroscopic treatment of borderline dysplasia could provide benefits whereas treatment of more dysplastic hips is controversial. Nevertheless, there is a lack of evidence for using arthroscopy alone in hips with a center edge angle <20°. Level IV, systematic review of Level IV studies. PMID:27583155
A three-dimensional finite element model for biomechanical analysis of the hip.
Chen, Guang-Xing; Yang, Liu; Li, Kai; He, Rui; Yang, Bin; Zhan, Yan; Wang, Zhi-Jun; Yu, Bing-Nin; Jian, Zhe
2013-11-01
The objective of this study was to construct a three-dimensional (3D) finite element model of the hip. The images of the hip were obtained from Chinese visible human dataset. The hip model includes acetabular bone, cartilage, labrum, and bone. The cartilage of femoral head was constructed using the AutoCAD and Solidworks software. The hip model was imported into ABAQUS analysis system. The contact surface of the hip joint was meshed. To verify the model, the single leg peak force was loaded, and contact area of the cartilage and labrum of the hip and pressure distribution in these structures were observed. The constructed 3D hip model reflected the real hip anatomy. Further, this model reflected biomechanical behavior similar to previous studies. In conclusion, this 3D finite element hip model avoids the disadvantages of other construction methods, such as imprecision of cartilage construction and the absence of labrum. Further, it provides basic data critical for accurately modeling normal and abnormal loads, and the effects of abnormal loads on the hip.
Rethinking Pedagogy in Urban Spaces: Implementing Hip-Hop Pedagogy in the Urban Science Classroom
ERIC Educational Resources Information Center
Adjapong, Edmund S.; Emdin, Christopher
2015-01-01
A significant amount of research regarding Hip-Hop Based Education (HHBE) fails to provide insight on how to incorporate elements of Hip-Hop into daily teaching practices; rather Hip-Hop based educators focus mainly on incorporating Hip-Hop culture into curricula. This study explores the benefits of using two specific Hip-Hop pedagogical practices…
Rolling rhythms in front crawl swimming with six-beat kick.
Sanders, Ross H; Psycharakis, Stelios G
2009-02-09
The purpose of this study was to establish the rhythm characteristics of skilled front crawl swimmers using a six-beat kick. These included the amplitudes of the first three Fourier harmonics (H1, H2, H3) and their percent contributions to power contained in the angular displacement signals of the shoulders, hips, knees, and ankles with respect to the longitudinal axis in line with the swimming direction. Three-dimensional video data of seven national/international level swimmers were collected during simulated 200m front crawl races in which swimmers maintained six-beat kicking patterns. Swimmers differed in all variables but had small variability across the four 50m laps. Modest changes occurred during the 200m, with the exception of shoulder roll, which remained constant and was represented almost entirely by a single sinusoid (H1). Changes across laps reached significance for swimming speed, stroke rate, hip roll, and H3 wave velocity between the knee and ankle. A H3 body wave of moderate and increasing velocity travelled caudally from hip to ankle. In the light of existing knowledge of aquatic locomotion this was compatible with the goal of generating propulsion in an efficient manner.
Agarwala, S; Jain, D; Joshi, V R; Sule, A
2005-03-01
To study the efficacy of alendronate, in the treatment of avascular necrosis (AVN) of the hip. Sixty patients with AVN of the hip (100 hips with AVN) were studied. The follow-up period ranged from 3 months to 5 yr. The most common cause of AVN was steroids. Parameters studied were walking time, standing time, pain and disability on a visual analogue scale (VAS), range of motion of the hip, X-ray and MRI of the hip. All patients were treated with alendronate 10 mg/day (or 70 mg/week) along with 500-1000 mg of daily calcium and vitamin D supplements, and were advised to avoid weight-bearing. NSAIDs and analgesics were permitted as needed and were recorded. Forty-one patients (71 AVN hips) with AVN have been followed up for a minimum of 1 yr, 24 patients (42 AVN hips) for 2 yr and 21 patients (37 AVN hips) for more than 2 yr (average 37 month). Fourteen patients have been followed up for less than 1 yr (3-9 months). Significant reduction in pain and disability scores (P < 0.001) and significant increase in standing and walking time (P < 0.001) were observed. All hip movements improved at 1 yr (P value 0.000-0.009) with an insignificant decline after that (P > 0.001). Radiologically, the hips either stabilized in the same grade or progressed by one grade. MRI showed a decrease in marrow oedema in most cases at the 1-yr follow-up. Six patients (10 hips) required surgery and there were two (three hips) dropouts. The drug was well tolerated and there was a reduction in NSAID requirement. Alendronate reduces pain, improves function and retards AVN progression. Early surgical intervention can be avoided in most patients.
Cumulative hip contact stress predicts osteoarthritis in DDH.
Mavcic, Blaz; Iglic, Ales; Kralj-Iglic, Veronika; Brand, Richard A; Vengust, Rok
2008-04-01
Hip stresses are generally believed to influence whether a hip develops osteoarthritis (OA); similarly, various osteotomies have been proposed to reduce contact stresses and the risk of OA. We asked whether elevated hip contact stress predicted osteoarthritis in initially asymptomatic human hips. We identified 58 nonoperatively treated nonsubluxated hips with developmental dysplasia (DDH) without symptoms at skeletal maturity; the control group included 48 adult hips without hip disease. The minimum followup was 20 years (mean, 29 years; range, 20-41 years). Peak contact stress was computed with the HIPSTRESS method using anteroposterior pelvic radiographs at skeletal maturity. The cumulative contact stress was determined by multiplying the peak contact stress by age at followup. We compared WOMAC scores and radiographic indices of OA. Dysplastic hips had higher mean peak contact and higher mean cumulative contact stress than normal hips. Mean WOMAC scores and percentage of asymptomatic hips in the study group (mean age 51 years) were similar to those in the control group (mean age 68 years). After adjusting for gender and age, the cumulative contact stress, Wiberg center-edge angle, body mass index, but not the peak contact stress, independently predicted the final WOMAC score in dysplastic hips but not in normal hips. Cumulative contact stress predicted early hip OA better than the Wiberg center-edge angle. Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Hip health at skeletal maturity: a population-based study of young adults with cerebral palsy.
Wawrzuta, Joanna; Willoughby, Kate L; Molesworth, Charlotte; Ang, Soon Ghee; Shore, Benjamin J; Thomason, Pam; Graham, H Kerr
2016-12-01
We studied 'hip health' in a population-based cohort of adolescents and young adults with cerebral palsy to investigate associations between hip morphology, pain, and gross motor function. Ninety-eight young adults (65 males, 33 females) from the birth cohort were identified as having developed hip displacement (migration percentage >30) and were reviewed at a mean age of 18 years 10 months (range 15-24y). Hip morphology was classified using the Melbourne Cerebral Palsy Hip Classification Scale (MCPHCS). Severity and frequency of pain were recorded using Likert scales. Gross motor function was classified by the Gross Motor Function Classification System (GMFCS). Hip pain was reported in 72% of participants. Associations were found between pain scores and both hip morphology and GMFCS. Median pain severity score for MCPHCS grades 1 to 4 was 2 (interquartile range [IQR] 1.0-3.0) compared to 7 (IQR 6.0-8.0) for grades 5 and 6 (severe subluxation or dislocation). Hip surveillance and access to surgery were associated with improved hip morphology and less pain. Poor hip morphology at skeletal maturity was associated with high levels of pain. Limited hip surveillance and access to surgery, rather than GMFCS, was associated with poor hip morphology. The majority of young adults who had access to hip surveillance, and preventive and reconstructive surgery, had satisfactory hip morphology at skeletal maturity and less pain. © 2016 Mac Keith Press.
Ruel, Allison V; Lee, Yuo-Yu; Boles, John; Boettner, Friedrich; Su, Edwin; Westrich, Geoffrey H
2015-07-01
After total hip replacement surgery, patients are eager to resume the activities of daily life, particularly driving. Most surgeons recommend waiting 6 weeks after surgery to resume driving; however, there is no evidence to indicate that patients cannot resume driving earlier. Our purpose was to evaluate when in the recovery period following THA that patients regain or improve upon their preoperative braking reaction time, allowing them to safely resume driving. We measured and compared pre- and postoperative braking reaction times of 90 patients from 3 different surgeons using a Fully Interactive Driving Simulator (Simulator Systems International, Tulsa, OK). We defined a return to safe braking reaction time as a return to a time value that is either equal to or less than the preoperative braking reaction time. Patients tested at 2 and 3 weeks after surgery had slower braking reaction times than preoperative times by an average of 0.069 and 0.009 s, respectively. At 4 weeks after surgery, however, patients improved their reaction times by 0.035 s (p = 0.0398). In addition, at 2, 3, and 4 weeks postoperatively, the results also demonstrated that patient less than 70 years of age recovered faster. Based upon the results of this study, most patients should be allowed to return to driving 4 weeks following minimally invasive primary total hip arthroplasty.
Optimizing Muscle Parameters in Musculoskeletal Modeling Using Monte Carlo Simulations
NASA Technical Reports Server (NTRS)
Hanson, Andrea; Reed, Erik; Cavanagh, Peter
2011-01-01
Astronauts assigned to long-duration missions experience bone and muscle atrophy in the lower limbs. The use of musculoskeletal simulation software has become a useful tool for modeling joint and muscle forces during human activity in reduced gravity as access to direct experimentation is limited. Knowledge of muscle and joint loads can better inform the design of exercise protocols and exercise countermeasure equipment. In this study, the LifeModeler(TM) (San Clemente, CA) biomechanics simulation software was used to model a squat exercise. The initial model using default parameters yielded physiologically reasonable hip-joint forces. However, no activation was predicted in some large muscles such as rectus femoris, which have been shown to be active in 1-g performance of the activity. Parametric testing was conducted using Monte Carlo methods and combinatorial reduction to find a muscle parameter set that more closely matched physiologically observed activation patterns during the squat exercise. Peak hip joint force using the default parameters was 2.96 times body weight (BW) and increased to 3.21 BW in an optimized, feature-selected test case. The rectus femoris was predicted to peak at 60.1% activation following muscle recruitment optimization, compared to 19.2% activation with default parameters. These results indicate the critical role that muscle parameters play in joint force estimation and the need for exploration of the solution space to achieve physiologically realistic muscle activation.
Ogrodnik, Justyna; Piszczatowski, Szczepan
2017-01-01
The aim of the present study was to evaluate the influence of modified morphological parameters of the muscle model and excitation pattern on the results of musculoskeletal system numerical simulation in a cerebral palsy patient. The modelling of the musculoskeletal system was performed in the AnyBody Modelling System. The standard model (MoCap) was subjected to modifications consisting of changes in morphological parameters and excitation patterns of selected muscles. The research was conducted with the use of data of a 14-year-old cerebral palsy patient. A reduction of morphological parameters (variant MI) caused a decrease in the value of active force generated by the muscle with changed geometry, and as a consequence the changes in active force generated by other muscles. A simulation of the abnormal excitation pattern (variant MII) resulted in the muscle's additional activity during its lengthening. The simultaneous modification of the muscle morphology and excitation pattern (variant MIII) points to the interdependence of both types of muscle model changes. A significant increase in the value of the reaction force in the hip joint was observed as a consequence of modification of the hip abductor activity. The morphological parameters and the excitation pattern of modelled muscles have a significant influence on the results of numerical simulation of the musculoskeletal system functioning.
Suckut, Tell; Wages, Jensen; Lyles, Heather; Perrin, Benjamin
2017-01-01
Background Only a small amount of evidence exists linking hip abductor weakness to dynamic knee valgus during static and dynamic activities. The associations of hip extensor strength and hip kinematics during the landing of a single leg hop are not known. Purpose: To determine if relationships exist between hip extensor and abductor strength and hip kinematics in both involved and uninvolved limb during the landing phase of a single leg hop in recreational athletes post anterior cruciate ligament (ACL) reconstruction. The presence of similar associations was also evaluated in healthy recreational athletes. Study Design Controlled Laboratory Study; Cross-sectional Methods Twenty-four recreational college-aged athletes participated in the study (12 post ACL reconstruction; 12 healthy controls). Sagittal and frontal plane hip kinematic data were collected for five trials during the landing of a single leg hop. Hip extensor and abductor isometric force production was measured using a hand-held dynamometer and normalized to participants’ height and weight. Dependent and independent t-tests were used to analyze for any potential differences in hip strength or kinematics within and between groups, respectively. Pearson's r was used to demonstrate potential associations between hip strength and hip kinematics for both limbs in the ACL group and the right limb in the healthy control group. Results Independent t-tests revealed that participants post ACL reconstruction exhibited less hip extensor strength (0.18 N/Ht*BW vs. 0.25 N/Ht*BW, p=<.01) and landed with greater hip adduction (9.0 º vs. 0.8 º, p=<.01) compared with their healthy counterparts. In the ACL group, Pearson's r demonstrated a moderate and indirect relationship (r=-.62, p=.03) between hip extensor strength and maximum hip abduction/adduction angle in the involved limb. A moderate and direct relationship between hip abductor strength and maximum hip flexion angle was demonstrated in the both the involved (r=.62) and uninvolved limb (r=.65, p=.02). No significant associations were demonstrated between hip extensor or abductor strength and hip flexion and/or abduction/adduction angles in the healthy group. Conclusion The results suggest that hip extensors may play a role in minimizing hip adduction in the involved limb while the hip abductors seem to play a role in facilitating hip flexion during the landing phase of a single leg hop for both limbs following ACL reconstruction. Researchers and clinicians alike should consider the importance of the hip extensors in playing a more prominent role in contributing to frontal plane motion. Levels of Evidence Level 2a PMID:28593088
Beretta, Elisa; De Momi, Elena; Camomilla, Valentina; Cereatti, Andrea; Cappozzo, Aurelio; Ferrigno, Giancarlo
2014-09-01
In computer-assisted knee surgery, the accuracy of the localization of the femur centre of rotation relative to the hip-bone (hip joint centre) is affected by the unavoidable and untracked pelvic movements because only the femoral pose is acquired during passive pivoting manoeuvres. We present a dual unscented Kalman filter algorithm that allows the estimation of the hip joint centre also using as input the position of a pelvic reference point that can be acquired with a skin marker placed on the hip, without increasing the invasiveness of the surgical procedure. A comparative assessment of the algorithm was carried out using data provided by in vitro experiments mimicking in vivo surgical conditions. Soft tissue artefacts were simulated and superimposed onto the position of a pelvic landmark. Femoral pivoting made of a sequence of star-like quasi-planar movements followed by a circumduction was performed. The dual unscented Kalman filter method proved to be less sensitive to pelvic displacements, which were shown to be larger during the manoeuvres in which the femur was more adducted. Comparable accuracy between all the analysed methods resulted for hip joint centre displacements smaller than 1 mm (error: 2.2 ± [0.2; 0.3] mm, median ± [inter-quartile range 25%; inter-quartile range 75%]) and between 1 and 6 mm (error: 4.8 ± [0.5; 0.8] mm) during planar movements. When the hip joint centre displacement exceeded 6 mm, the dual unscented Kalman filter proved to be more accurate than the other methods by 30% during multi-planar movements (error: 5.2 ± [1.2; 1] mm). © IMechE 2014.
Ikemura, Satoshi; Mawatari, Taro; Matsui, Gen; Iguchi, Takahiro; Mitsuyasu, Hiroaki
2016-10-01
The prognosis of patients with a subchondral insufficiency fracture remains unclear. The purpose of this study was to investigate the correlation between locations of bone marrow edema (BME) lesions and clinical outcome in patients with a subchondral insufficiency fracture of the hip. We retrospectively reviewed 15 consecutive hips in 14 patients who were diagnosed with subchondral insufficiency fracture of the hip at our institution between April 2013 and September 2014. This study included five males (six hips) and nine females (nine hips), ranging from 36 to 83 years of age (mean age: 66 years). The mean duration from the onset of hip pain to MRI examination was 1.8 months (range 0.5-5 months). Both clinical and imaging findings were investigated. Based on the findings of MR images, BME lesion in the femoral head alone was observed in six patients (six hips), BME lesion in the acetabulum alone was observed in one patient (two hips) and BME lesions in both the femoral head and acetabulum were observed in seven patients (seven hips). 3 of 15 hips resulted in rapidly destructive arthrosis and their BME lesions were observed in both the femoral head and acetabulum. 8 of 15 hips successfully healed by conservative treatment and BME lesions in 7 of these 8 hips were observed in only the femoral head or acetabulum. The results of this study indicate that the locations of BME lesions (femoral side alone, acetabular side alone or both) may be related to the clinical outcome in patients with a subchondral insufficiency fracture of the hip. Patients with subchondral insufficiency fracture of the hip in whom BME lesions were observed in both the femoral head and acetabulum may have a higher risk to need to undergo total hip arthroplasty.
Beaulieu, Mélanie L.; Wojtys, Edward M.; Ashton-Miller, James A.
2015-01-01
Background A reduced range of hip internal rotation is associated with increased peak anterior cruciate ligament (ACL) strain and risk for injury. It is unknown, however, whether limiting the available range of internal femoral rotation increases the susceptibility of the ACL to fatigue failure. Hypothesis Risk of ACL failure is significantly greater in female knee specimens with a limited range of internal femoral rotation, smaller femoral-ACL attachment angle, and smaller tibial eminence volume during repeated in vitro simulated single-leg pivot landings. Study Design Controlled laboratory study. Methods A custom-built testing apparatus was used to simulate repeated single-leg pivot landings with a 4×-body weight impulsive load that induces knee compression, knee flexion, and internal tibial torque in 32 paired human knee specimens from 8 male and 8 female donors. These test loads were applied to each pair of specimens, in one knee with limited internal femoral rotation and in the contralateral knee with femoral rotation resisted by 2 springs to simulate the active hip rotator muscles’ resistance to stretch. The landings were repeated until ACL failure occurred or until a minimum of 100 trials were executed. The angle at which the ACL originates from the femur and the tibial eminence volume were measured on magnetic resonance images. Results The final Cox regression model (P = .024) revealed that range of internal femoral rotation and sex of donor were significant factors in determining risk of ACL fatigue failure. The specimens with limited range of internal femoral rotation had a failure risk 17.1 times higher than did the specimens with free rotation (P = .016). The female knee specimens had a risk of ACL failure 26.9 times higher than the male specimens (P = .055). Conclusion Limiting the range of internal femoral rotation during repetitive pivot landings increases the risk of an ACL fatigue failure in comparison with free rotation in a cadaveric model. Clinical Relevance Screening for restricted internal rotation at the hip in ACL injury prevention programs as well as in individuals with ACL injuries and/or reconstructions is warranted. PMID:26122384
Fabrication and characterization of DLC coated microdimples on hip prosthesis heads.
Choudhury, Dipankar; Ay Ching, Hee; Mamat, Azuddin Bin; Cizek, Jan; Abu Osman, Noor Azuan; Vrbka, Martin; Hartl, Martin; Krupka, Ivan
2015-07-01
Diamond like carbon (DLC) is applied as a thin film onto substrates to obtain desired surface properties such as increased hardness and corrosion resistance, and decreased friction and wear rate. Microdimple is an advanced surface modification technique enhancing the tribological performance. In this study, DLC coated microdimples were fabricated on hip prosthesis heads and their mechanical, material and surface properties were characterized. An Electro discharge machining (EDM) oriented microdrilling was utilized to fabricate a defined microdimple array (diameter of 300 µm, depth of 70 µm, and pitch of 900 µm) on stainless steel (SS) hip prosthesis heads. The dimpled surfaces were then coated by hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) layers by using a magnetron sputtering technology. A preliminary tribology test was conducted on these fabricated surfaces against a ceramic ball in simulated hip joint conditions. It was found that the fabricated dimples were perpendicular to the spherical surfaces and no cutting-tools wear debris was detected inside the individual dimples. The a-C:H and Ta-C coatings increased the hardness at both the dimple edges and the nondimpled region. The tribology test showed a significant reduction in friction coefficient for coated surfaces regardless of microdimple arrays: the lowest friction coefficient was found for the a-C:H samples (µ = 0.084), followed by Ta-C (µ = 0.119), as compared to the SS surface (µ = 0.248). © 2014 Wiley Periodicals, Inc.
Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo
2017-12-01
Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.
Effects of Imbalanced Muscle Loading on Hip Joint Development and Maturation
Ford, Caleb A.; Nowlan, Niamh C.; Thomopoulos, Stavros; Killian, Megan L.
2017-01-01
The mechanical loading environment influences the development and maturation of joints. In this study, the influence of imbalanced muscular loading on joint development was studied using localized chemical denervation of hip stabilizing muscle groups in neonatal mice. It was hypothesized that imbalanced muscle loading, targeting either gluteal muscles or quadriceps muscles, would lead to bilateral hip joint asymmetry, as measured by acetabular coverage, femoral head volume and bone morphometry, and femoral-acetabular shape. The contralateral hip joints as well as age-matched, uninjected mice were used as controls. Altered bone development was analyzed using micro-computed tomography, histology, and image registration techniques at postnatal days (P) 28, 56, and 120. This study found that unilateral muscle unloading led to reduced acetabular coverage of the femoral head, lower total volume, lower bone volume ratio, and lower mineral density, at all three time points. Histologically, the femoral head was smaller in unloaded hips, with thinner triradiate cartilage at P28 and thinner cortical bone at P120 compared to contralateral hips. Morphological shape changes were evident in unloaded hips at P56. Unloaded hips had lower trabecular thickness and increased trabecular spacing of the femoral head compared to contralateral hips. The present study suggests that decreased muscle loading of the hip leads to altered bone and joint shape and growth during postnatal maturation. Statement of Clinical Significance: Adaptations from altered muscle loading during postnatal growth investigated in this study have implications on developmental hip disorders that result from asymmetric loading, such as patients with limb-length inequality or dysplasia. PMID:27391299
O'Dwyer Lancaster-Jones, O; Williams, S; Jennings, L M; Thompson, J; Isaac, G H; Fisher, J; Al-Hajjar, M
2017-09-23
The aim of this study was to develop a preclinical in vitro method to predict the occurrence and severity of edge loading condition associated with the dynamic separation of the centres of the head and cup (in the absence of impingement) for variations in surgical positioning of the cup. Specifically, this study investigated the effect of both the variations in the medial-lateral translational mismatch between the centres of the femoral head and acetabular cup and the variations in the cup inclination angles on the occurrence and magnitude of the dynamic separation, the severity of edge loading, and the wear rate of ceramic-on-ceramic hip replacement bearings in a multi-station hip joint simulator during a walking gait cycle. An increased mismatch between the centres of rotation of the femoral head and acetabular cup resulted in an increased level of dynamic separation and an increase in the severity of edge loading condition which led to increased wear rate in ceramic-on-ceramic bearings. Additionally for a given translational mismatch, an increase in the cup inclination angle gave rise to increased dynamic separation, worst edge loading conditions, and increased wear. To reduce the occurrence and severity of edge loading, the relative positions (the mismatch) of the centres of rotation of the head and the cup should be considered alongside the rotational position of the acetabular cup. This study has considered the combination of mechanical and tribological factors for the first time in the medial-lateral axis only, involving one rotational angle (inclination) and one translational mismatch. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.
Assessing risk factors for early hip osteoarthritis in activity-related hip pain: a Delphi study
Jackson, K A; Glyn-Jones, S; Batt, M E; Arden, N K; Newton, J L
2015-01-01
Objective Hip pain and injury as a result of activity can lead to the development of early hip osteoarthritis (OA) in susceptible individuals. Our understanding of the factors that increase susceptibility continues to evolve. The ability to clearly identify individuals (and cohorts) with activity-related hip pain who are at risk of early hip OA is currently lacking. The purpose of this study was to gain expert consensus on which key clinical measures might help predict the risk of early hip OA in individuals presenting with activity-related hip pain. The agreed measures would constitute a standardised approach to initial clinical assessment to help identify these individuals. Methods This Dephi study used online surveys to gain concordance of expert opinion in a structured process of ‘rounds’. In this study, we asked ‘What outcome measures are useful in predicting hip OA in activity-related hip pain?’ The Delphi panel consisted of experts from sport and exercise medicine, orthopaedics, rheumatology, physiotherapy and OA research. Results The study identified key clinical measures in the history, examination and investigations (plain anteroposterior radiograph and femoroacetabular impingement views) that the panel agreed would be useful in predicting future risk of hip OA when assessing activity-related hip pain. The panel also agreed that certain investigations and tests (eg, MR angiography) did not currently have a role in routine assessment. There was a lack of consensus regarding the role of MRI, patient-reported outcome measures (PROMs) and certain biomechanical and functional assessments. Conclusions We provide a standardised approach to the clinical assessment of patients with activity-related hip pain. Assessment measures rejected by the Delphi panel were newer, more expensive investigations that currently lack evidence. Assessment measures that did not reach consensus include MRI and PROMs. Their role remains ambiguous and would benefit from further research. PMID:26419679
Revision Hip Arthroscopy Indications and Outcomes: A Systematic Review.
Sardana, Vandit; Philippon, Marc J; de Sa, Darren; Bedi, Asheesh; Ye, Lily; Simunovic, Nicole; Ayeni, Olufemi R
2015-10-01
To identify the indications and outcomes in patients undergoing revision hip arthroscopy. The electronic databases Embase, Medline, HealthStar, and PubMed were searched from 1946 to July 19, 2014. Two blinded reviewers searched, screened, and evaluated the data quality of the studies using the Methodological Index for Non-Randomized Studies scale. Data were abstracted in duplicate. Agreement and descriptive statistics are presented. Six studies were included (3 prospective case series and 3 retrospective chart reviews), with a total of 448 hips examined. The most common indications for revision hip arthroscopy included residual femoroacetabular impingement (FAI), labral tears, and chondral lesions. The mean interval between revision arthroscopy and the index procedure was 25.6 months. Overall, the modified Harris Hip Score improved by a mean of 33.6% (19.3 points) from the baseline score at 1-year follow-up. In 14.6% of patients, further surgical procedures were required, including re-revision hip arthroscopy (8.0%), total hip replacement (5.6%), and hip resurfacing (1.0%). Female patients more commonly underwent revision hip arthroscopy (59.7%). The current evidence examined in this review supports revision hip arthroscopy as a successful intervention to improve functional outcomes (modified Harris Hip Score) and relieve pain in patients with residual symptoms after primary FAI surgery, although the outcomes are inferior when compared with a matched cohort of patients undergoing primary hip arthroscopy for FAI. The main indication for revision is a candidate who has symptoms due to residual cam- or pincer-type deformity that was either unaddressed or under-resected during the index operation. However, it is important to consider that the studies included in this review are of low-quality evidence. Surgeons should consider incorporating a minimum 2-year follow-up for individuals after index hip-preservation surgery because revisions tended to occur within this time frame. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Mechanisms of Hip Fracture in Owerri, Nigeria, and its Associated Variables
Onwukamuche, CK; Ekezie, J; Anyanwu, GE; Nwaiwu, CO; Agu, AU
2013-01-01
Background: Hip fracture has been associated with various risk factors, including osteoporosis, excessive alcohol consumption, physical inactivity, visual impairment, aging, sex, rural/urban inhabitation, race and climatic variations. Mechanisms of hip fractures in many parts of the world have been documented, and include road traffic accident (RTA), gunshot injury, fall from heights and many others. There is paucity of such documentation in Owerri, Nigeria. Aim: This study was designed to investigate the mechanism of hip fractures in Owerri, Nigeria, and to determine its prevailing factors. Materials and Methods: The study was conducted in hospitals located in Owerri, Nigeria. Cases of hip fracture were identified from the medical register while data were sourced from the medical record department for hip fractures that occurred between 1st January 2002 and 31st December 2008 for patients resident in Owerri and aged between 10 years and above. Results: The study uncovered a total of 105 cases of hip fractures over the study period in 65% (n = 68) males and 35% (n = 37) females. Proportion of hip fractures as a result of fragility fracture mechanisms was significantly higher in females than in the males (P < 0.001), while the reverse was the case for RTA mechanisms. In the same vein, proportion of hip fractures as a result of moderate trauma mechanisms was significantly higher in the elderly than in the young patients (P < 0.001), while the reverse was the case for RTA mechanisms. Conclusion: Mechanism of hip fractures in Owerri, Nigeria, can be associated with gender and age. RTA had the largest single contributory mechanism of hip fractures in Owerri. Therefore, public health campaigns and promotions should be created to reduce the influence of RTA on hip fracture among this population. Among the elderly population, hip fracture was mostly sustained from fragility trauma mechanisms, suggesting that osteoporosis is a major contributory factor of hip fracture among this population. PMID:23919195
Dufour, A B; Roberts, B; Broe, K E; Kiel, D P; Bouxsein, M L; Hannan, M T
2012-02-01
We examined the relation between a biomechanical measure, factor-of-risk, and hip fracture risk in 1,100 men and women from the Framingham Study and found that it predicted hip fracture (men, ORs of 1.8; women, 1.2-1.4). Alternative methods of predicting hip fracture are needed since 50% of adults who fracture do not have osteoporosis by bone mineral density (BMD) measurements. One method, factor-of-risk (Φ), computes the ratio of force on the hip in a fall to femoral strength. We examined the relation between Φ and hip fracture in 1,100 subjects from the Framingham Study with measured hip BMD, along with weight, height, and age, collected in 1988-1989. We estimated both peak and attenuated force applied to the hip in a sideways fall from standing height, where attenuated force incorporated cushioning effects of trochanteric soft tissue. Femoral strength was estimated from femoral neck BMD, using cadaveric femoral strength data. Sex-specific, age-adjusted survival models were used to calculate hazard ratios (HR) and 95% confidence intervals for the relation between Φ (peak), Φ (attenuated), and their components with hip fracture. In 425 men and 675 women (mean age, 76 years), 136 hip fractures occurred over median follow-up of 11.3 years. Factor-of-risk, Φ, was associated with increased age-adjusted risk for hip fracture. One standard deviation increase in Φ (peak) and Φ (attenuated) was associated with HR of 1.88 and 1.78 in men and 1.23 and 1.41 in women, respectively. Examining components of Φ, in women, we found fall force and soft tissue thickness were predictive of hip fracture independent of femoral strength (was estimated from BMD). Thus, both Φ (peak) and Φ (attenuated) predict hip fracture in men and women. These findings suggest additional studies of Φ predicting hip fracture using direct measurements of trochanteric soft tissue.
Prather, H; Harris-Hayes, M; Hunt, D; Steger-May, K; Mathew, V; Clohisy, JC
2012-01-01
Objective The objectives of this study are the following: 1) report passive hip ROM in asymptomatic young adults, 2) report the intra-tester and inter-tester reliability of hip ROM measurements among testers of multiple disciplines, 3) report the results of provocative hip tests and tester agreement. Design descriptive epidemiology study Setting tertiary university Participants Twenty-eight young adult volunteers without musculoskeletal symptoms, history of disorder or surgery involving the lumbar spine or lower extremities were enrolled and completed the study. Methods Asymptomatic young adult volunteers completed questionnaires and were examined by two blinded examiners during a single session. The testers were physical therapists and physicians. Hip range of motion and provocative tests were completed by both examiners on each hip. Main Outcome Measurements Inter and intra-rater reliability for ROM and agreement for provocative tests was determined. Results Twenty-eight asymptomatic adults with mean age 31 years old (range 18–51 years) and mean modified Harris Hip Score of 99.5 ± 1.5 and UCLA Activity score of 8.8 ± 1.2 completed the study. Intra-rater agreement was excellent for all hip range of motion measurements, with intraclass correlation coefficients (ICCs) ranging from 0.76 to 0.97 with similar agreement if the examiner was a physical therapist or a physician. Excellent inter-rater reliability was found for hip flexion ICC 0.87 (95% CI 0.78 to 0.92), supine internal rotation ICC 0.75 (95% CI 0.60 to 0.84) and prone internal rotation ICC 0.79 (95% CI 0.66 to 0.87). The least reliable measurements were supine hip abduction (ICC 0.34) and supine external rotation (ICC 0.18). Agreement between examiners ranged from 96–100% for provocative hip tests which included the hip impingement, resisted straight leg raise, FABER/Patrick’s and log roll tests. Conclusions Specific hip ROM measures show excellent inter-rater reliability and provocative hip tests show good agreement among multiple examiners and medical disciplines. Further studies are needed to assess the utilization of these measurements and tests as a part of a hip screening examination to assess for young adults at risk intra-articular hip disorders prior to the onset of degenerative changes. PMID:20970757
Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T
1996-01-01
The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0.0001) and 1/3 width defect (p = 0.0222). The total absolute contact areas for all defect conditions were significantly less than the intact conditions. The results of this study reconfirm the observation that posterior wall fractures of the acetabulum significantly alter the articular contact characteristics in the hip during single leg stance. The relationship between defect size and changes in joint contact showed that the smallest defect resulted in the greatest alteration in joint contact areas, whereas larger defects resulted in minor increments of change in contact area. This finding is of concern because the clinical practice of managing acetabular fractures nonoperatively if the hip joint is stable is based on the supposition that the joint retains enough integrity to function without undue risk of late posttraumatic osteoarthritis. A better understanding of the natural history of stable posterior wall acetabular fractures is needed to ascertain whether some of these fractures merit operative repair.
HIP AND GLENOHUMERAL PASSIVE RANGE OF MOTION IN COLLEGIATE SOFTBALL PLAYERS
Plummer, Hillary; Brambeck, Allison
2016-01-01
Background and Purpose Range of motion deficits at the hip and glenohumeral joint (GHJ) may contribute to the incidence of injury in softball players. With injury in softball players on the rise, softball related studies in the literature are important. The purpose of this study was to examine hip and GHJ passive range of motion (PROM) patterns in collegiate softball players. Hypothesis It was hypothesized that the position players would exhibit significantly different PROM patterns than pitchers. Additionally, position players would exhibit significantly different side-to-side differences in PROM for both the hip and GHJ compared to pitchers. Study Design Prospective cohort study. Methods Forty-nine collegiate softball players (19.63 ± 1.15 years; 170.88 ± 8.08 cm; 72.96 ± 19.41 kg) participated. Passive hip and GHJ internal (IR) and external rotation (ER) measures were assessed. Glenohumeral PROM was measured with the participants supine with the arm abducted to 90 °. The measurements were recorded when the scapula began to move or a firm capsular end-feel was achieved. The hip was positioned in 90 ° of flexion and passively rotated until a capsular end-feel was achieved. Total PROM was calculated by taking the sum of IR and ER for both the hip and GHJ. Results No significant side-to-side PROM differences were observed in pitchers, at the GHJ or hip joint. Position players throwing side hip IR was significantly greater than the non-throwing side hip (p = 0.002). The non-throwing side hip had significantly greater ER compared to the throwing side hip (p = 0.002). When examining side-to-side differences at the GHJ, IR was significantly greater in the non-throwing shoulder (p = 0.047). No significant differences in total range of motion of the hip and GHJ were observed. Conclusion In the current study, position players displayed side-to-side differences in hip and GHJ IR PROM while no statistically significant differences were observed in the softball pitchers. The findings of the current study add to the body of literature related to PROM in throwing athletes, additionally these are the first hip IR and ER PROM data presented in softball players. Level of Evidence Level 3 PMID:27757286
Magaziner, Jay; Chiles, Nancy; Orwig, Denise
2017-01-01
Hip fracture is a significant public health problem affecting an estimated 1.6 million persons annually. The consequences of hip fracture are also significant, with more than half of those who sustain a fracture either dying or not returning to functional abilities present before fracture required to function independently. The Baltimore Hip Studies (BHS) is a program of research that for more than 30 years has been doing investigations to identify, develop, and evaluate strategies to optimize recovery from hip fracture. This paper provides an overview of known outcomes and recovery patterns following a hip fracture, which are derived primarily from the BHS. Target areas and timing for interventions based on this recovery sequence are suggested. The paper concludes with a discussion of some of the areas that the next generation of studies needs to concentrate on in order to advance knowledge about the care of hip fracture patients to maximize their recovery. PMID:26484873
Relationship between hip and core strength and frontal plane alignment during a single leg squat.
Stickler, Laurie; Finley, Margaret; Gulgin, Heather
2015-02-01
The purpose of this study was to examine the relationship between frontal plane kinematics of the single leg squat and strength of the trunk and hip in females. Forty healthy females participated in this study. An isometric "make" test using a dynamometer was used to assess peak force normalized to body weight for hip abduction, hip extension, hip external rotation, and a sidelying plank test. Two-dimensional software was used to analyze the frontal plane projection angle (FPPA) and pelvic angle during a single leg squat to 60°. All 4 strength factors were significantly correlated with the FPPA, ranging from r = 0.396 to r = 0.466. During multiple regression analysis, hip abduction strength was the greatest predictor of the variation in FPPA at r(2) = 0.22, p = 0.002. Thus, hip abduction strength accounted for 22% of the variation in the FPPA during the single leg squat. The only strength factor demonstrating a significant correlation with the pelvic angle was hip extension strength (r = 0.550, p < 0.001). Clinicians should consider the role of the hip abductors, hip external rotators, hip extensors and core musculature on the impact on the FPPA during a single squat, with focus on the hip abductors. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gabbe, B J; Bailey, M; Cook, J L; Makdissi, M; Scase, E; Ames, N; Wood, T; McNeil, J J; Orchard, J W
2010-09-01
To establish the relationship between the history of hip and groin injuries in elite junior football players prior to elite club recruitment and the incidence of hip and groin injuries during their elite career. Retrospective cohort study. Analysis of existing data. 500 Australian Football League (AFL) players drafted from 1999 to 2006 with complete draft medical assessment data. Previous history of hip/groin injury, anthropometric and demographic information. The number of hip/groin injuries resulting in > or =1 missed AFL game. Data for 500 players were available for analysis. 86 (17%) players reported a hip/groin injury in their junior football years. 159 (32%) players sustained a hip/groin injury in the AFL. Players who reported a previous hip or groin injury at the draft medical assessment demonstrated a rate of hip/groin injury in the AFL >6 times higher (IRR 6.24, 95% CI 4.43 to 8.77) than players without a pre-AFL hip or groin injury history. This study demonstrated that a hip or groin injury sustained during junior football years is a significant predictor of missed game time at the elite level due to hip/groin injury. The elite junior football period should be targeted for research to investigate and identify modifiable risk factors for the development of hip/groin injuries.
Zeni, Joseph; Pozzi, Federico; Abujaber, Sumayah; Miller, Laura
2014-01-01
Patients with hip osteoarthritis demonstrate limited range of motion, muscle weakness and altered biomechanics; however, few studies have evaluated the relationships between physical impairments and movement asymmetries. The purpose of this study was to identify the physical impairments related to movement abnormalities in patients awaiting total hip arthroplasty. We hypothesized that muscle weakness and pain would be related to greater movement asymmetries. Fifty-six subjects who were awaiting total hip arthroplasty were enrolled. Pain was assessed using a 0 to 10 scale, range of motion was assessed with the Harris Hip Score and isometric hip abductor strength was tested using a hand-held dynamometer. Trunk, pelvis and hip angles and moments in the frontal and sagittal planes were measured during walking using three dimensional motion analysis. During gait, subjects had 3.49 degrees less peak hip flexion and 8.82 degrees less extension angles (p<0.001) and had 0.03 Nm/k*m less hip abduction moment on the affected side (p=0.043). Weaker hip muscles were related to greater pelvis (r=−0.291) and trunk (r=−0.332) rotations in the frontal plane. These findings suggest that hip weakness drives abnormal movement patterns at the pelvis and trunk in patients with hip osteoarthritis to a greater degree than hip pain. PMID:25492583
Anticipatory postural adjustments during lateral step motion in patients with hip osteoarthritis.
Tateuchi, Hiroshige; Ichihashi, Noriaki; Shinya, Masahiro; Oda, Shingo
2011-02-01
Patients with hip osteoarthritis (OA) have difficulty with mediolateral postural control. Since the symptom of hip OA includes joint pain, which mostly occurs upon initial movement, patients with hip OA might have disabling problems with movement initiation. This study aimed to identify the movement strategy during the anticipatory postural adjustments in the lateral step motion in patients with hip OA. We studied 18 female subjects with unilateral hip OA and 10 healthy subjects, and measured temporal, kinetic, and kinematic variables. Patients with hip OA required a longer duration of anticipation phase than the control subjects, the total duration of lateral stepping was not different between the groups. Displacement of the center of mass to the supporting (affected) side during the anticipation phase was not different between the two groups. These findings suggest that, in patients with hip OA, the center of mass slowly moved to the affected side. Furthermore, patients with hip OA showed greater shift of the trunk to the supporting side than did the control subjects. These movement characteristics might contribute to the achievement of both protection of the affected hip joint and quickness in the subsequent lateral step in patients with hip OA.
Effect of Posture on Hip Angles and Moments during Gait
Lewis, Cara L.; Sahrmann, Shirley A.
2014-01-01
Anterior hip pain is common in young, active adults. Clinically, we have noted that patients with anterior hip pain often walk in a swayback posture, and that their pain is reduced when the posture is corrected. The purpose of this study was to investigate a potential mechanism for the reduction in pain by testing the effect of posture on movement patterns and internal moments during gait in healthy subjects. Fifteen subjects were instructed to walk while maintaining three postures: 1) natural, 2) swayback, and 3) forward flexed. Kinematic and force data were collected using a motion capture system and a force plate. Walking in the swayback posture resulted in a higher peak hip extension angle, hip flexor moment and hip flexion angular impulse compared to natural posture. In contrast, walking in a forward flexed posture resulted in a decreased hip extension angle and decreased hip flexion angular impulse. Based on these results, walking in a swayback posture may result in increased forces required of the anterior hip structures, potentially contributing to anterior hip pain. This study provides a potential biomechanical mechanism for clinical observations that posture correction in patients with hip pain is beneficial. PMID:25262565
Effect of posture on hip angles and moments during gait.
Lewis, Cara L; Sahrmann, Shirley A
2015-02-01
Anterior hip pain is common in young, active adults. Clinically, we have noted that patients with anterior hip pain often walk in a swayback posture, and that their pain is reduced when the posture is corrected. The purpose of this study was to investigate a potential mechanism for the reduction in pain by testing the effect of posture on movement patterns and internal moments during gait in healthy subjects. Fifteen subjects were instructed to walk while maintaining three postures: 1) natural, 2) swayback, and 3) forward flexed. Kinematic and force data were collected using a motion capture system and a force plate. Walking in the swayback posture resulted in a higher peak hip extension angle, hip flexor moment and hip flexion angular impulse compared to natural posture. In contrast, walking in a forward flexed posture resulted in a decreased hip extension angle and decreased hip flexion angular impulse. Based on these results, walking in a swayback posture may result in increased forces required of the anterior hip structures, potentially contributing to anterior hip pain. This study provides a potential biomechanical mechanism for clinical observations that posture correction in patients with hip pain is beneficial. Copyright © 2014 Elsevier Ltd. All rights reserved.
Azevedo, Daniel Camara; Paiva, Edson Barreto; Lopes, Alexia Moura Abuhid; Santos, Henrique de Oliveira; Carneiro, Ricardo Luiz; Rodrigues, André Soares; de Andrade, Marco Antonio Percope; Novais, Eduardo N; Van Dillen, Linda R
2016-11-01
Study Design Cross-sectional, case-control design. Background Pelvic movement has been considered a possible discriminating parameter associated with femoroacetabular impingement (FAI) symptom onset. Decreased pelvic rotation has been found during squatting in people with FAI when compared to people with healthy hips. However, it is possible that changes in pelvic movement may occur in other hip conditions because of pain and may not be specific to FAI. Objectives To compare sagittal pelvic rotation during hip flexion and in sitting between people with FAI and people with other symptomatic hip conditions. Methods Thirty people with symptomatic FAI, 30 people with other symptomatic hip conditions, and 20 people with healthy hips participated in the study. Sagittal pelvic rotation was calculated based on measures of pelvic alignment in standing, hip flexion to 45° and 90°, and sitting. Results There were significant differences in sagittal pelvic rotation among the 3 groups in all conditions (P<.05). Post hoc analyses revealed that participants in the symptomatic FAI group had less pelvic rotation during hip flexion to 45° and 90° compared to participants in the other symptomatic hip conditions group and the hip-healthy group (mean difference, 1.2°-1.9°). In sitting, participants in the other symptomatic hip conditions group had less posterior pelvic rotation compared to those in the hip-healthy group (mean difference, 3.9°). Conclusion People with symptomatic FAI have less posterior pelvic rotation during hip flexion when compared to people with other symptomatic hip conditions and those with healthy hips. Level of Evidence Diagnosis, level 4. J Orthop Sports Phys Ther 2016;46(11):957-964. Epub 29 Sep 2016. doi:10.2519/jospt.2016.6713.
Correlation of the Y-Balance Test with Lower-limb Strength of Adult Women
Lee, Dong-Kyu; Kim, Gyoung-Mo; Ha, Sung-Min; Oh, Jae-Seop
2014-01-01
[Purpose] The purpose of this study was to elucidate the relationship between Y-balance test (YBT) distance and the lower-limb strength of adult women. [Subjects] Forty women aged 45 to 80 years volunteered for this study. [Methods] The participants were tested for maximal muscle strength of the lower limbs (hip extensors, hip flexors, hip abductors, knee extensors, knee flexors, and ankle dorsiflexors) and YBT distances in the anterior, posteromedial, and posterolateral directions. Pearson’s correlation coefficient was used to quantify the linear relationships between YBT distances and lower-limb strength. [Results] Hip extensor and knee flexor strength were positively correlated with YBT anterior distance. Hip extensor, hip abductor, and knee flexor strength were positively correlated with the YBT posteromedial distance. Hip extensor and knee flexor strength were positively correlated with YBT posterolateral distance. [Conclusion] There was a weak correlation between lower-limb strength (hip extensors, hip abductors, and knee flexors) and dynamic postural control as measured by the YBT. PMID:24926122
Scheel, Alexander K.; Matteson, Eric L.; Dasgupta, Bhaskar; Bruyn, George A. W.; Ohrndorf, Sarah; Werner, Carola; Schmidt, Wolfgang A.
2009-01-01
Objective. A study supported by the EULAR and the ACR being conducted to establish classification criteria for polymyalgia rheumatica (PMR) will include ultrasound examination of the shoulders and hips. Ultrasound (US) depicts glenohumeral joint effusion, biceps tenosynovitis, subdeltoid bursitis, hip joint synovitis, and trochanteric bursitis in PMR. These findings may aid in distinguishing PMR from other diseases. The purpose of this study was to assess standards and US interreader agreement of participants in the PMR classification criteria study. Methods. Sixteen physicians in four groups examined shoulders and hips of 4 patients and 4 healthy adults with ultrasound. Overall agreement and interobserver agreement were calculated. Results. The overall agreement (OA) between groups was 87%. The OA for healthy shoulders was 88.8%, for healthy hips 100%, for shoulders with pathology 85.2%, and 74.3% for hips with pathology, respectively. Conclusion. There was a high degree of agreement found for the examination of healthy shoulders and pathologic hips. Agreement was moderate for pathologic shoulders and perfect for healthy hips. US of shoulder and hips performed by different examiners is a reliable and feasible tool for assessment of PMR related disease pathology and can be incorporated into a classification criteria study. PMID:20130800
Contribution of the Pubofemoral Ligament to Hip Stability: A Biomechanical Study.
Martin, Hal D; Khoury, Anthony N; Schröder, Ricardo; Johnson, Eric; Gómez-Hoyos, Juan; Campos, Salvador; Palmer, Ian J
2017-02-01
To determine the isolated function of the pubofemoral ligament of the hip capsule and its contribution to hip stability in external/internal rotational motion during flexion greater than 30° and abduction. Thirteen hips from 7 fresh-frozen pelvis-to-toe cadavers were skeletonized from the lumbar spine to the distal femur with the capsular ligaments intact. Computed tomographic imaging was performed to ensure no occult pathological state existed, and assess bony anatomy. Specimens were placed on a surgical table in supine position with lower extremities resting on a custom-designed polyvinylchloride frame. Hip internal and external rotation was measured with the hip placed into a combination of the following motions: 30°, 60°, 110° hip flexion and 0°, 20°, 40° abduction. Testing positions were randomized. The pubofemoral ligament was released and measurements were repeated, followed by releasing the ligamentum teres. Analysis of the 2,106 measurements recorded demonstrates the pubofemoral ligament as a main controller of hip internal rotation during hip flexion beyond 30° and abduction. Hip internal rotation was increased up to 438.9% (P < .001) when the pubofemoral ligament was released and 412.9% (P < .001) when both the pubofemoral and teres ligament were released, compared with the native state. The hypothesis of the pubofemoral ligament as one of the contributing factors of anterior inferior hip stability by controlling external rotation of the hip in flexion beyond 30° and abduction was disproved. The pubofemoral ligament maintains a key function in limiting internal rotation in the position of increasing hip flexion beyond 30° and abduction. This cadaveric study concludes previous attempts at understanding the anatomical and biomechanical function of the capsular ligaments and their role in hip stability. The present study contributes to the understanding of hip stability and biomechanical function of the pubofemoral ligament. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Griffin, Xavier L; Achten, Juul; Sones, William; Cook, Jonathan; Costa, Matthew L
2018-01-26
Sliding hip screw fixation is well established in the treatment of trochanteric fractures of the hip. The X-Bolt Dynamic Hip Plating System builds on the successful design features of the sliding hip screw but differs in the nature of the fixation in the femoral head. A randomised pilot study suggested that the X-bolt Dynamic Hip Plating System might provide similar health-related quality of life while reducing the risk of revision surgery when compared with the sliding hip screw. This is the protocol for a multicentre randomised trial of sliding hip screw versus X-Bolt Dynamic Hip Plating System for patients 60 years and over treated for a trochanteric fracture of the hip. Multicentre, multisurgeon, parallel, two-arm, randomised controlled trial. Patients aged 60 years and older with a trochanteric hip fracture are potentially eligible. Participants will be randomly allocated on a 1:1 basis to either sliding hip screw or X-Bolt Dynamic Hip Plating System. Otherwise, all care will be in accordance with National Institute for Health and Care Excellence guidance. A minimum of 1128 patients will be recruited to obtain 90% power to detect a 0.075-point difference in EuroQol-5D health-related quality of life at 4 months postrandomisation. Secondary outcomes include mortality, residential status, revision surgery and radiographic measures. The treatment effect will be estimated using a two-sided t-test adjusted for age, gender and cognitive impairment based on an intention-to-treat analysis. National Research Ethics Committee approved this study on 5 February 2016 (16/WM/0001). The study is sponsored by the University of Oxford and funded through an investigator initiated grant by X-Bolt Orthopaedics. A manuscript for a high-impact peer-reviewed journal will be prepared, and the results will be disseminated to patients through local mechanisms at participating centres. ISRCTN92825709. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Kivlan, Benjamin R; Nho, Shane J; Christoforetti, John J; Ellis, Thomas J; Matsuda, Dean K; Salvo, John P; Wolff, Andrew B; Van Thiel, Geoffrey S; Stubbs, Allston J; Carreira, Dominic S
As the field of hip arthroscopy continues to grow rapidly, our understanding of the population of patients undergoing hip arthroscopy has led to improved diagnosis and management of hip joint pathologies. The Multicenter Arthroscopic Study of the Hip (MASH) Study Group conducts multicenter clinical studies in arthroscopic hip preservation surgery. Patients undergoing arthroscopic hip preservation surgery are enrolled in a large prospective longitudinal cohort at 10 separate sites nationwide by 10 fellowship-trained hip arthroscopists. In this study, we collected epidemiologic data on the 1738 patients who enrolled between January 2014 and November 2016. These data include demographics, pathologic entities treated, patient-reported measures of disease, and surgical treatment preferences. Our study results showed that patients who elected hip arthroscopy were younger to middle-aged white females with pain primarily located in the groin region. Most had pain for at least 1 year, and it was commonly exacerbated by sitting and athletic activities. Patients reported clinically significant pain and functional limitation and a decrease in physical and mental health. It was not uncommon for patients to have undergone another, related surgery and nonoperative treatments, including intra-articular injection and/or physical therapy, before surgery. There was a high incidence of abnormal hip morphology suggestive of a cam lesion, but the incidence of arthritic changes on radiographs was relatively low. Labral tear was the most common diagnosis, and most often it was addressed with repair. Many patients underwent femoroplasty, acetabuloplasty, and chondroplasty in addition to labral repair.
Kendal, Adrian R; Prieto-Alhambra, Daniel; Arden, Nigel K; Judge, Andrew
2013-01-01
Objectives To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. Design Retrospective cohort study. Setting English hospital episode statistics database linked to mortality records from the Office for National Statistics. Population All adults who underwent primary elective hip replacement for osteoarthritis from April 1999 to March 2012. The exposure of interest was prosthesis type: cemented total hip replacement, uncemented total hip replacement, and metal-on-metal hip resurfacing. Confounding variables included age, sex, Charlson comorbidity index, rurality, area deprivation, surgical volume, and year of operation. Main outcome measures All cause mortality. Propensity score matching was used to minimise confounding by indication. Kaplan-Meier plots estimated the probability of survival up to 10 years after surgery. Multilevel Cox regression modelling, stratified on matched sets, described the association between prosthesis type and time to death, accounting for variation across hospital trusts. Results 7437 patients undergoing metal-on-metal hip resurfacing were matched to 22 311 undergoing cemented total hip replacement; 8101 patients undergoing metal-on-metal hip resurfacing were matched to 24 303 undergoing uncemented total hip replacement. 10 year rates of cumulative mortality were 271 (3.6%) for metal-on-metal hip resurfacing versus 1363 (6.1%) for cemented total hip replacement, and 239 (3.0%) for metal-on-metal hip resurfacing versus 999 (4.1%) for uncemented total hip replacement. Patients undergoing metal-on-metal hip resurfacing had an increased survival probability (hazard ratio 0.51 (95% confidence interval 0.45 to 0.59) for cemented hip replacement; 0.55 (0.47 to 0.65) for uncemented hip replacement). There was no evidence for an interaction with age or sex. Conclusions Patients with hip osteoarthritis undergoing metal-on-metal hip resurfacing have reduced mortality in the long term compared with those undergoing cemented or uncemented total hip replacement. This difference persisted after extensive adjustment for confounding factors available in our data. The study results can be applied to matched populations, which exclude patients who are very old and have had complex total hip replacements. Although residual confounding is possible, the observed effect size is large. These findings require validation in external cohorts and randomised clinical trials. PMID:24284336
Forecasting the burden of future postmenopausal hip fractures.
Omsland, T K; Magnus, J H
2014-10-01
A growing elderly population is expected worldwide, and the rate of hip fractures is decisive for the future fracture burden. Significant declines in hip fracture rates in Norway, the USA, France, Germany, and the UK are required to counteract the impact of the ageing effects. This study aims to evaluate the consequences of the expected growth of the elderly population worldwide on the hip fracture burden using Norway as an example. Furthermore, we wanted to estimate the decline in hip fracture rates required to counteract the anticipated increase in the burden of hip fracture for Norway, the USA, France, Germany, and the UK. The burden of future postmenopausal hip fractures in Norway were estimated given (1) constant age-specific rates, (2) continued decline, and (3) different cohort scenarios. Based on population projection estimates and population age-specific hip fracture rates in women 65 years and older, we calculated the required declines in hip fracture rates needed to counteract the growing elderly populations in Norway, the USA, France, Germany, and the UK. The level of age-specific hip fracture rates had a huge impact on the future hip fracture burden in Norway. Even if the hip fracture rates decline at the same speed, a 22 % increase in the burden of hip fractures can be expected by 2040. An annual decline in hip fracture rates of 1.1-2.2 % until 2040 is required to counteract the effects of the growing elderly population on the future burden of hip fractures in Norway, the USA, France, Germany, and the UK. Hip fracture rates have a great impact on the burden of hip fractures. The rates will have to decline significantly to counteract the impact of a growing elderly population. A change in preventive strategies and further studies are warranted to identify the complex causes associated to hip fractures.
Nguyen, Anh-Dung; Zuk, Emma F; Baellow, Andrea L; Pfile, Kate R; DiStefano, Lindsay J; Boling, Michelle C
2017-09-01
Risk of anterior cruciate ligament (ACL) injuries in young female athletes increases with age, appearing to peak during maturation. Changes in hip muscle strength and range of motion (ROM) during this time may contribute to altered dynamic movement patterns that are known to increase risk of ACL injuries. Understanding the longitudinal changes in hip strength and ROM is needed to develop appropriate interventions to reduce the risk of ACL injuries. To examine the longitudinal changes in hip strength and ROM in female youth soccer players. Longitudinal descriptive study. Field setting. 14 female youth soccer athletes (14.1 ± 1.1 y, 165.8 ± 5.3 cm, 57.5 ± 9.9 kg) volunteered as part of a multiyear risk factor screening project. Clinical measures of hip strength and ROM were collected annually over 3 consecutive years. Passive hip internal rotation (IR), external rotation (ER), abduction (ABD), and adduction (ADD) ROM were measured with a digital inclinometer. Isometric hip ABD and extension (EXT) strength were evaluated using a hand-held dynamometer. Separate repeated-measures ANOVAs compared hip strength and ROM values across 3 consecutive years (P < .05). As youth female soccer players increased in age, there were no changes in normalized hip ABD (P = .830) or EXT strength (P = .062) across 3 consecutive years. Longitudinal changes in hip ROM were observed with increases in hip IR (P = .001) and ABD (P < .001), while hip ADD (P = .009) and ER (P < .001) decreased. Anatomical changes at the hip occur as youth female soccer players increase in age. While there are no changes in hip strength, there is an increase in hip IR and ABD ROM with a concomitant decrease in hip ER and ADD ROM. The resulting asymmetries in hip ROM may decrease the activation and force producing capabilities of the hip muscles during dynamic activities, contributing to altered lower extremity mechanics known to increase the risk of ACL injuries.
An, Ruopeng
2015-12-01
High prices remain a formidable barrier for many people, especially those of low socioeconomic status, to adopt a healthier diet. The Food, Conservation, and Energy Act of 2008 mandated the U.S. Department of Agriculture (USDA) to conduct a pilot study to assess the impact of making fruits and vegetables more affordable for households in the Supplemental Nutrition Assistance Program (SNAP). Based on the USDA final report of the Healthy Incentives Pilot (HIP), a large-scale randomized trial in 2011-2012 that provided 30% rebate on targeted fruits and vegetables to 7500 study participants enrolled in the SNAP, we constructed a decision model to evaluate the cost-effectiveness of an expansion of the HIP to all SNAP households nationwide. The estimated life-time per capita costs of the HIP to the Federal government is $1323 in 2012 U.S. dollars, and the average gains in quality-adjusted life expectancy to a SNAP participant is 0.082 quality-adjusted life year (QALY), resulting in an incremental cost-effectiveness ratio (ICER) of $16,172 per QALY gained. Sensitivity analysis using Monte Carlo simulations indicates a 94.4% and 99.6% probability that the estimated ICER would be lower than the cost-effective threshold of $50,000 and $100,000 per QALY gained, respectively. Moreover, the estimated ICER of the HIP expansion tends to be competitive in comparison to other interventions that aimed at promoting fruit/vegetable intake among adult population. Findings from this study suggest that a nationwide expansion of the HIP is likely to nudge SNAP households towards purchasing and consuming more targeted fruits and vegetables. However, diet behavior modification is proportional to price change. When people's actual eating behaviors and what dietary guidelines recommend differ by several folds, even a 30% rebate closes just a small fraction of that gap and has limited beneficial impact on participants' weight management, disease prevention, and health-related quality of life. Copyright © 2015 Elsevier Ltd. All rights reserved.
Numerical Simulation of Sintering Process in Ceramic Powder Injection Moulded Components
NASA Astrophysics Data System (ADS)
Song, J.; Barriere, T.; Liu, B.; Gelin, J. C.
2007-05-01
A phenomenological model based on viscoplastic constitutive law is presented to describe the sintering process of ceramic components obtained by powder injection moulding. The parameters entering in the model are identified through sintering experiments in dilatometer with the proposed optimization method. The finite element simulations are carried out to predict the density variations and dimensional changes of the components during sintering. A simulation example on the sintering process of hip implant in alumina has been conducted. The simulation results have been compared with the experimental ones. A good agreement is obtained.
Passive moment about the hip in straight leg raising.
Lee, R Y; Munn, J
2000-06-01
The purpose of this examine is to study the load-deformation characteristics of the hip in straight leg raising. An experimental study in which passive moment about the hip was determined as a function of hip angle. Straight leg raising is widely employed in clinical examination, and there is little information on its mechanical characteristics. Fourteen healthy volunteers were recruited for this study. Three trials of straight leg raise tests were performed while subjects lay supine on a plinth that was fitted with load cells. An electrogoniometer was employed to measure hip flexion during the test. Resistive moment at the hip was determined using a dynamic biomechanical model. The present experimental method was shown to be highly reliable. The moment-angle curves of all subjects were shown to follow an exponential function. Stiffness and strain energy of posterior hip tissues could be derived from the moment-angle curves. Evaluation of such elastic properties is clinically important as they may be altered with injuries of the tissues. Clinically, contracture of hamstring muscles and other posterior hip tissues is evaluated by measuring the available range of hip flexion in straight leg raising. However, this does not provide any information on the elastic properties of the tissues. The present study reports a reliable method of evaluating such properties.
Marshall, Amelia Rose; Noronha, Marcos de; Zacharias, Anita; Kapakoulakis, Theo; Green, Rodney
2016-04-27
Hip osteoarthritis (OA) is a major cause of morbidity. Rehabilitation for this population focuses on strengthening the hip muscles, particularly the abductors, however the deficit in function of these muscles is unclear. To review the evidence for the differences in structure and function of hip abductors (gluteus medius and minimus and tensor fascia lata) in hip OA. A systematic review was conducted using MEDLINE, AMED, CINAHL and SportDISCUS, from the earliest date to September 2013. Studies that compared hip OA patients with controls, or the unaffected contralateral hip were included. Studies needed to report data on an outcome related to gross gluteal muscle function. An initial yield of 141 studies was reduced to 22 after application of inclusion/exclusion criteria. Meta-analysis confirmed greater hip abductor strength in the control group (standardized mean difference = SMD -0.93, 95%CI -1.70 to -0.16) and the unaffected limb (SMD -0.26, 95%CI -0.48 to -0.04). Meta-analyses showed no differences in muscle size either between groups or limbs. Few electromyography studies have been reported and meta-analysis was not possible. Hip abductor strength is reduced in OA patients when compared to healthy controls and to the unaffected limb. Data on muscle size and activity is limited.
Effects of imbalanced muscle loading on hip joint development and maturation.
Ford, Caleb A; Nowlan, Niamh C; Thomopoulos, Stavros; Killian, Megan L
2017-05-01
The mechanical loading environment influences the development and maturation of joints. In this study, the influence of imbalanced muscular loading on joint development was studied using localized chemical denervation of hip stabilizing muscle groups in neonatal mice. It was hypothesized that imbalanced muscle loading, targeting either gluteal muscles or quadriceps muscles, would lead to bilateral hip joint asymmetry, as measured by acetabular coverage, femoral head volume and bone morphometry, and femoral-acetabular shape. The contralateral hip joints as well as age-matched, uninjected mice were used as controls. Altered bone development was analyzed using micro-computed tomography, histology, and image registration techniques at postnatal days (P) 28, 56, and 120. This study found that unilateral muscle unloading led to reduced acetabular coverage of the femoral head, lower total volume, lower bone volume ratio, and lower mineral density, at all three time points. Histologically, the femoral head was smaller in unloaded hips, with thinner triradiate cartilage at P28 and thinner cortical bone at P120 compared to contralateral hips. Morphological shape changes were evident in unloaded hips at P56. Unloaded hips had lower trabecular thickness and increased trabecular spacing of the femoral head compared to contralateral hips. The present study suggests that decreased muscle loading of the hip leads to altered bone and joint shape and growth during postnatal maturation. Statement of Clinical Significance: Adaptations from altered muscle loading during postnatal growth investigated in this study have implications on developmental hip disorders that result from asymmetric loading, such as patients with limb-length inequality or dysplasia. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1128-1136, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Orces, Carlos H; Gavilanez, Enrique Lopez
2017-12-07
The Ecuadorian hospital discharge system examined trends in hip fracture hospitalization rates among older adults. A significant upward trend in hip fracture rates occurred in both genders over the study period. Previous research has reported increasing hip fracture rates in Ecuador. Thus, this study aimed to extend previous findings by examining the nationwide incidence of hip fractures among adults aged 65 years and older between 1999 and 2016. A secondary objective was to compare hip fracture trends among older Ecuadorians with their counterparts in the United States (U.S.). The National Hospital Discharge System and the Healthcare Cost and Utilization Project net were assessed to identify older adults hospitalized with a principal diagnosis of hip fractures in Ecuador and the U.S., respectively. The Joinpoint regression analysis software was used to examine the average annual percent change in hip fracture rates. A total of 20,091 adults with a mean age of 82.3 (SD 8.1) years were hospitalized with a principal diagnosis of hip fractures during the study period. After an adjustment for age, hip fracture rates increased annually on average by 4.6% (95% CI 3.8%, 5.4%) from 96.4/100,000 in 1999 to 173.1/100,000 persons in 2016. Between 1999 and 2014, hip fracture age-adjusted rates decreased on average by - 2.5% (95% CI - 2.7%, - 2.3%) among older adults in the U.S. while hip fracture rates steadily increased by 4.6% (95% CI, 3.6%, 5.7%) per year in their Ecuadorian counterparts. Hip fracture rates markedly increased among older adults in Ecuador. The present findings should alert public health authorities to implement policies of osteoporosis awareness and prevention in Ecuador.
Medium-term results of ceramic-on-polyethylene Zweymüller-Plus total hip arthroplasty.
Li, H; Zhang, S; Wang, X M; Lin, J H; Kou, B L
2017-08-01
The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing. A retrospective study was conducted to review the results after a minimum of 12.4 years of 207 consecutive total hip arthroplasties in 185 patients in Peking University People's Hospital in China using the Zweymüller SL-Plus stem in combination with the Bicon-Plus threaded cup and ceramic-on-polyethylene bearing between October 1994 and April 2000. During the study period, two patients (2 hips) died and 25 patients (28 hips) were lost to follow-up. Two hips were revised for aseptic loosening of the Bicon-Plus cup. The mean clinical and radiological follow-up was 14.1 years (range, 12.4-16.5 years) for the remaining 156 patients (175 hips). The mean (standard deviation) Harris Hip score for the 175 hips increased significantly from 39.3 (3.8) preoperatively to 94.1 (2.5) postoperatively at a mean follow-up of 14.1 years (P<0.05). Focal osteolysis was observed in seven (4.0%) of 175 stems and three (1.7%) of 175 cups. The Kaplan-Meier survival with revision for any reason as the end-point was 99.03% (95% confidence interval, 95%-100%). The high survival rate of the cementless Zweymüller-Plus system with ceramic-on-polyethylene bearing at mid-term follow-up makes this total hip arthroplasty system reliable for patients with various hip joint diseases.
Lassen, M R; Fisher, W; Mouret, P; Agnelli, G; George, D; Kakkar, A; Mismetti, P; Turpie, A G G
2012-05-01
Semuloparin is a novel ultra-low-molecular-weight heparin under development for venous thromboembolism (VTE) prevention in patients at increased risk, such as surgical and cancer patients. Three Phase III studies compared semuloparin and enoxaparin after major orthopedic surgery: elective knee replacement (SAVE-KNEE), elective hip replacement (SAVE-HIP1) and hip fracture surgery (SAVE-HIP2). All studies were multinational, randomized and double-blind. Semuloparin and enoxaparin were administered for 7-10 days after surgery. Mandatory bilateral venography was to be performed between days 7 and 11. The primary efficacy endpoint was a composite of any deep vein thrombosis, non-fatal pulmonary embolism or all-cause death. Safety outcomes included major bleeding, clinically relevant non-major (CRNM) bleeding, and any clinically relevant bleeding (major bleeding plus CRNM). In total, 1150, 2326 and 1003 patients were randomized in SAVE-KNEE, SAVE-HIP1 and SAVE-HIP2, respectively. In all studies, the incidences of the primary efficacy endpoint were numerically lower in the semuloparin group vs. the enoxaparin group, but the difference was statistically significant only in SAVE-HIP1. In SAVE-HIP1, clinically relevant bleeding and major bleeding were significantly lower in the semuloparin vs. the enoxaparin group. In SAVE-KNEE and SAVE-HIP2, clinically relevant bleeding tended to be higher in the semuloparin group, but rates of major bleeding were similar in the two groups. Other safety parameters were generally similar between treatment groups. Semuloparin was superior to enoxaparin for VTE prevention after hip replacement surgery, but failed to demonstrate superiority after knee replacement surgery and hip fracture surgery. Semuloparin and enoxaparin exhibited generally similar safety profiles. © 2012 International Society on Thrombosis and Haemostasis.
Sex differences of hip morphology in young adults with hip pain and labral tears.
Hetsroni, Iftach; Dela Torre, Katrina; Duke, Gavin; Lyman, Stephen; Kelly, Bryan T
2013-01-01
To compare hip morphology between young men and women who presented with hip pain and labral tears. A retrospective review of our hip arthroscopy registry from March 2008 to June 2010 was completed. We identified 217 patients (249 hips) who were between the ages of 18 to 30 years. The inclusion criteria were (1) insidious-onset hip pain or worsening pain after low-energy sports trauma, (2) positive hip impingement sign, (3) Tönnis grades 0 to 1, (4) magnetic resonance imaging showing labral tear, and (5) primary hip arthroscopy confirming labral tear. Forty-five patients (52 hips) were excluded for the following reasons: (1) revision hip arthroscopy, (2) high-energy hip trauma, (3) history of surgery involving the femur or pelvis, (4) previous fractures of the femur or pelvis, (5) Tönnis grades 2 or above, (6) proliferative disease of the hip (i.e., synovial chondromatosis, pigmented villonodular synovitis), (7) neuromuscular disease (i.e., cerebral palsy), and (8) deformities related to Legg-Calvé-Perthes disease or developmental dysplasia of the hip. Therefore, the cohort study group included 105 (61%) men (123 [62.4%] hips) and 67 (39%) women (74 [37.6%] hips). Sex comparisons were made for the following variables measured on preoperative hip computed tomography scans: alpha angle, acetabular version, femoral version, lateral center-edge angle, and neck-shaft angle. Women had smaller alpha angles (47.8°v 63.6°, P < .001), increased acetabular version (17.3°v 13.9°, P < .001), and increased femoral anteversion (14.4°v 12.1°, P = .05). In young adults with hip pain and labral tears, women have smaller alpha angles and hips that are generally more anteverted. Therefore, in women, cam lesions may be more subtle, preoperative hip version analyses should be encouraged, and rim trimming may need to be cautiously planned to avoid increasing contact stresses at weight-bearing areas after such a procedure. Level III, retrospective comparative study. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Tate, Jeremiah; Suckut, Tell; Wages, Jensen; Lyles, Heather; Perrin, Benjamin
2017-06-01
Only a small amount of evidence exists linking hip abductor weakness to dynamic knee valgus during static and dynamic activities. The associations of hip extensor strength and hip kinematics during the landing of a single leg hop are not known. Purpose: To determine if relationships exist between hip extensor and abductor strength and hip kinematics in both involved and uninvolved limb during the landing phase of a single leg hop in recreational athletes post anterior cruciate ligament (ACL) reconstruction. The presence of similar associations was also evaluated in healthy recreational athletes. Controlled Laboratory Study; Cross-sectional. Twenty-four recreational college-aged athletes participated in the study (12 post ACL reconstruction; 12 healthy controls). Sagittal and frontal plane hip kinematic data were collected for five trials during the landing of a single leg hop. Hip extensor and abductor isometric force production was measured using a hand-held dynamometer and normalized to participants' height and weight. Dependent and independent t-tests were used to analyze for any potential differences in hip strength or kinematics within and between groups, respectively. Pearson's r was used to demonstrate potential associations between hip strength and hip kinematics for both limbs in the ACL group and the right limb in the healthy control group. Independent t-tests revealed that participants post ACL reconstruction exhibited less hip extensor strength (0.18 N/Ht*BW vs. 0.25 N/Ht*BW, p=<.01) and landed with greater hip adduction (9.0 º vs. 0.8 º, p=<.01) compared with their healthy counterparts. In the ACL group, Pearson's r demonstrated a moderate and indirect relationship ( r =-.62, p=.03) between hip extensor strength and maximum hip abduction/adduction angle in the involved limb. A moderate and direct relationship between hip abductor strength and maximum hip flexion angle was demonstrated in the both the involved ( r =.62) and uninvolved limb ( r =.65, p=.02). No significant associations were demonstrated between hip extensor or abductor strength and hip flexion and/or abduction/adduction angles in the healthy group. The results suggest that hip extensors may play a role in minimizing hip adduction in the involved limb while the hip abductors seem to play a role in facilitating hip flexion during the landing phase of a single leg hop for both limbs following ACL reconstruction. Researchers and clinicians alike should consider the importance of the hip extensors in playing a more prominent role in contributing to frontal plane motion. Level 2a.
Levy, David M; Kuhns, Benjamin D; Chahal, Jaskarndip; Philippon, Marc J; Kelly, Bryan T; Nho, Shane J
2016-09-01
To determine whether the hip arthroscopy literature to date has shown outcomes consistent with published patient acceptable symptomatic state (PASS) and minimal clinically important difference (MCID) estimates. All clinical investigations of hip arthroscopy using modified Harris Hip Score (mHHS) and/or Hip Outcome Score (HOS) outcomes with at least 1 year of follow-up were reviewed. Ninety-one studies (9,746 hips) were included for review. Eighty-one studies (9,317 hips) contained only primary hip arthroscopies and were the primary focus of this review. The remaining studies (429 hips) did not exclude patients with prior surgical history and were thus considered separately. Mean mHHS, HOS-ADL (Activities of Daily Living) and HOS-SS (Sports-Specific) scores were compared with previously published PASS and MCID values. After 31 ± 20 months, 5.8% of study populations required revision arthroscopy and 5.5% total hip arthroplasty. A total of 88%, 25%, and 30% of study populations met PASS for mHHS, HOS-ADL, and HOS-SS, respectively, and 97%, 90%, and 93% met MCID. On bivariate analysis, increasing age was associated with significantly worse postoperative mHHS (P < .01, R(2) = 0.14), HOS-SS (P = .05, R(2) = 0.12), and rates of reoperation (P = .02, R(2) = 0.08). Increasing body mass index was associated with significantly worse HOS-ADL (P = .02, R(2) = 0.35) and HOS-SS (P = .03, R(2) = 0.30). In this meta-analysis of 81 studies of primary hip arthroscopy, we have found that more than 90% of study populations meet MCID standards for the most commonly used patient-reported outcomes measures in hip arthroscopy literature, mHHS and HOS. Eighty-eight percent meet PASS standards for the mHHS, but PASS standards are far more difficult to achieve for HOS-ADL (25%) and HOS-SS (30%) subscales. Differences in psychometric properties of the mHHS and HOS likely account for the discrepancies in PASS. Level IV, systematic review of Level I to IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Flynn, John M; Ramirez, Norman; Betz, Randal; Mulcahey, Mary Jane; Pino, Franz; Herrera-Soto, Jose A; Carlo, Simon; Cornier, Alberto S
2010-01-01
A syndrome of children with short stature, bilateral hip dislocations, radial head dislocations, carpal coalitions, scoliosis, and cavus feet in Puerto Rican children, was reported by Steel et al in 1993. The syndrome was described as a unique entity with dismal results after conventional treatment of dislocated hips. The purpose of this study is to reevaluate this patient population with a longer follow-up and delineate the clinical and radiologic features, treatment outcomes, and the genetic characteristics. This is a retrospective cohort study of 32 patients in whom we evaluated the clinical, imaging data, and genetic characteristics. We compare the findings and quality of life in patients with this syndrome who have had attempts at reduction of the hips versus those who did not have the treatment. Congenital hip dislocations were present in 100% of the patients. There was no attempt at reduction in 39% (25/64) of the hips. In the remaining 61% (39/64), the hips were treated with a variety of modalities fraught with complications. Of those treated, 85% (33/39) remain dislocated, the rest of the hips continue subluxated with acetabular dysplasia and pain. The group of hips that were not treated reported fewer complaints and limitation in daily activities compared with the hips that had attempts at reduction. Steel syndrome is a distinct clinical entity characterized by short stature, bilateral hip and radial head dislocation, carpal coalition, scoliosis, cavus feet, and characteristic facial features with dismal results for attempts at reduction of the hips. Prognostic Study Level II.
Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian
2016-05-01
To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.
The Hip Impact Protection Project: Design and Methods
Barton, Bruce A; Birge, Stanley J; Magaziner, Jay; Zimmerman, Sheryl; Ball, Linda; Brown, Kathleen M; Kiel, Douglas P
2013-01-01
Background Nearly 340,000 hip fractures occur each year in the U.S. With current demographic trends, the number of hip fractures is expected to double at least in the next 40 years. Purpose The Hip Impact Protection Project (HIP PRO) was designed to investigate the efficacy and safety of hip protectors in an elderly nursing home population. This paper describes the innovative clustered matched-pair research design used in HIP PRO to overcome the inherent limitations of clustered randomization. Methods Three clinical centers recruited 37 nursing homes to participate in HIP PRO. They were randomized so that the participating residents in that home received hip protectors for either the right or left hip. Informed consent was obtained from either the resident or the resident's responsible party. The target sample size was 580 residents with replacement if they dropped out, had a hip fracture, or died. One of the advantages of the HIP PRO study design was that each resident was his/her own case and control, eliminating imbalances, and there was no confusion over which residents wore pads (or on which hip). Limitations Generalizability of the findings may be limited. Adherence was higher in this study than in other studies because of: (1) the use of a run-in period, (2) staff incentives, and (3) the frequency of adherence assessments. The use of a single pad is not analogous to pad use in the real world and may have caused unanticipated changes in behavior. Fall assessment was not feasible, limiting the ability to analyze fractures as a function of falls. Finally, hip protector designs continue to evolve so that the results generated using this pad may not be applicable to other pad designs. However, information about factors related to adherence will be useful for future studies. Conclusions The clustered matched-pair study design avoided the major problem with previous cluster-randomized investigations of this question – unbalanced risk factors between the experimental group and the control group. Because each resident served as his/her own control, the effects of unbalanced risk factors on treatment effect were virtually eliminated. In addition, the use of frequent adherence assessments allowed us to study the effect of various demographic and environmental factors on adherence, which was vital for the assessment of efficacy. PMID:18697849
The Sla2p/HIP1/HIP1R family: similar structure, similar function in endocytosis?
Gottfried, Irit; Ehrlich, Marcelo; Ashery, Uri
2010-02-01
HIP1 (huntingtin interacting protein 1) has two close relatives: HIP1R (HIP1-related) and yeast Sla2p. All three members of the family have a conserved domain structure, suggesting a common function. Over the past decade, a number of studies have characterized these proteins using a combination of biochemical, imaging, structural and genetic techniques. These studies provide valuable information on binding partners, structure and dynamics of HIP1/HIP1R/Sla2p. In general, all suggest a role in CME (clathrin-mediated endocytosis) for the three proteins, though some differences have emerged. In this mini-review we summarize the current views on the roles of these proteins, while emphasizing the unique attributes of each family member.
Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.
Nithyaprakash, R; Shankar, S; Uddin, M S
2018-05-01
Hip implants subject to gait loading due to occupational activities are potentially prone to failures such as osteolysis and aseptic loosening, causing painful revision surgeries. Highly risky gait activities such as carrying a load, stairs up or down and ladder up or down may cause excessive loading at the hip joint, resulting in generation of wear and related debris. Estimation of wear under the above gait activities is thus crucial to design and develop a new and improved implant component. With this motivation, this paper presents an assessment of wear generation of PCD-on-PCD (poly crystalline diamond) hip implants using finite element (FE) analysis. Three-dimensional (3D) FE model of hip implant along with peak gait and peak flexion angle for each activity was used to estimate wear of PCD for 10 million cycles. The maximum and minimum initial contact pressures of 206.19 MPa and 151.89 MPa were obtained for carrying load of 40 kg and sitting down or getting up activity. The simulation results obtained from finite element model also revealed that the maximum linear wear of 0.585 μm occurred for the patients frequently involved in sitting down or getting up gait activity and maximum volumetric wear of 0.025 mm 3 for ladder up gait activity. The stair down activity showed the least linear and volumetric wear of 0.158 μm and 0.008 mm 3 , respectively, at the end of 10 million cycles. Graphical abstract Computational wear assessment of hip implants subjected to physically demanding tasks.
Knikou, Maria; Chaudhuri, Debjani; Kay, Elizabeth; Schmit, Brian D.
2006-01-01
The aim of this study was to establish the contribution of hip-mediated sensory feedback to spinal interneuronal circuits during dynamic conditions in people with incomplete spinal cord injury (SCI). Specifically, we investigated the effects of synergistic and antagonistic group I afferents on the soleus H-reflex during imposed sinusoidal hip movements. The soleus H-reflex was conditioned by stimulating the common peroneal nerve (CPN) at short (2, 3, and 4 ms) and long (80, 100, and 120 ms) conditioning test (C-T) intervals to assess the reciprocal and pre-synaptic inhibition of the soleus H-reflex, respectively. The soleus H-reflex was also conditioned by medial gastrocnemius (MG) nerve stimulation at C-T intervals ranging from 4 to 7 ms to assess changes in autogenic Ib inhibition during hip movement. Sinusoidal hip movements were imposed to the right hip joint at 0.2 Hz by the Biodex system while subjects were supine. The effects of sinusoidal hip movement on five leg muscles along with hip, knee, and ankle joint torques were also established during sensorimotor conditioning of the reflex. Phase-dependent modulation of antagonistic and synergistic muscle afferents was present during hip movement, with the reciprocal, pre-synaptic, and Ib inhibition to be significantly reduced during hip extension and reinforced during hip flexion. Reflexive muscle and joint torque responses – induced by the hip movement – were entrained to specific phases of hip movement. This study provides evidence that hip-mediated input acts as a controlling signal of pre- and post-alpha motoneuronal control of the soleus H-reflex. The expression of these spinal interneuronal circuits during imposed sinusoidal hip movements is discussed with respect to motor recovery in humans after SCI. PMID:16782072
Boyle, Christopher; Kim, Il Yong
2011-06-03
Since the late 1980s, computational analysis of total hip arthroplasty (THA) prosthesis components has been completed using macro-level bone remodeling algorithms. The utilization of macro-sized elements requires apparent bone densities to predict cancellous bone strength, thereby, preventing visualization and analysis of realistic trabecular architecture. In this study, we utilized a recently developed structural optimization algorithm, design space optimization (DSO), to perform a micro-level three-dimensional finite element bone remodeling simulation on the human proximal femur pre- and post-THA. The computational simulation facilitated direct performance comparison between two commercially available prosthetic implant stems from Zimmer Inc.: the Alloclassic and the Mayo conservative. The novel micro-level approach allowed the unique ability to visualize the trabecular bone adaption post-operation and to quantify the changes in bone mineral content by region. Stress-shielding and strain energy distribution were also quantified for the immediate post-operation and the stably fixated, post-remodeling conditions. Stress-shielding was highest in the proximal region and remained unchanged post-remodeling; conversely, the mid and distal portions show large increases in stress, suggesting a distal shift in the loadpath. The Mayo design conserves bone mass, while simultaneously reducing the incidence of stress-shielding compared to the Alloclassic, revealing a key benefit of the distinctive geometry. Several important factors for stable fixation, determined in clinical evaluations from the literature, were evident in both designs: high levels of proximal bone loss and distal bone densification. The results suggest this novel computational framework can be utilized for comparative hip prosthesis shape, uniquely considering the post-operation bone remodeling as a design criterion. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kawai, Toshiyuki; Tanaka, Chiaki; Kanoe, Hiroshi
2014-03-10
Several authors reported encouraging results of total hip arthroplasty (THA) for Crowe IV hips performed using shortening osteotomy. However, few papers have documanted the results of THA for Crowe IV hips without shortening osteotomy. The aim of the present study was to assess the long term-results of cemented THAs for Crowe group IV hips performed without subtrochanteric shortening osteotomy. We have assessed the long term results of 27 cemented total hip arthroplasty (THA) performed without subtrochanteric osteotomy for Crowe group IV hip. All THAs were performed via transtrochanteric approach. After a mean follow-up of 10.6 (6 to 17.9) years, 25 hips (92.6%) had survived without revision surgery and survivorship analysis gave a survival rate of 96.3% at 10 years with any revision surgery as the end point. Although mean limb lengthening was 3.2 (1.0 to 5.1) cm, no hips developed nerve palsy. Complications occurred in four hips, necessitating revision surgery in two. Among the four complications, three involved the greater trochanter, two of which occurred in cases where braided cables had been used to reattach the greater trochanter. Although we encountered four complications, including three trochanteric problems, our findings suggest that THA without subtrochanteric shortening osteotomy can provide satisfactory long-term results in patients with Crowe IV hip.
OpenSim Versus Human Body Model: A Comparison Study for the Lower Limbs During Gait.
Falisse, Antoine; Van Rossom, Sam; Gijsbers, Johannes; Steenbrink, Frans; van Basten, Ben J H; Jonkers, Ilse; van den Bogert, Antonie J; De Groote, Friedl
2018-05-29
Musculoskeletal modeling and simulations have become popular tools for analyzing human movements. However, end-users are often not aware of underlying modeling and computational assumptions. This study investigates how these assumptions affect biomechanical gait analysis outcomes performed with Human Body Model and the OpenSim gait2392 model. We compared joint kinematics, kinetics, and muscle forces resulting from processing data from seven healthy adults with both models. Although outcome variables had similar patterns, there were statistically significant differences in joint kinematics (maximal difference: 9.8 ± 1.5 degrees in sagittal plane hip rotation), kinetics (maximal difference: 0.36 ± 0.10 N·m/kg in sagittal plane hip moment), and muscle forces (maximal difference: 8.51 ± 1.80 N/kg for psoas). These differences might be explained by differences in hip and knee joint center locations up to 2.4 ± 0.5 and 1.9 ± 0.2 cm in the postero-anterior and infero-superior directions, respectively, and by the offset in pelvic reference frames of about 10 degrees around the medio-lateral axis. Model choice may not influence the conclusions in clinical settings where the focus is on interpreting deviations from reference data but will affect the conclusions of mechanical analyses where the goal is to obtain accurate estimates of kinematics and loading.
Richard, F; Villars, M; Thibaud, S
2013-08-01
The viscoelastic behavior of articular cartilage changes with progression of osteoarthritis. The objective of this study is to quantify this progression and to propose a viscoelastic model of articular cartilage taking into account the degree of osteoarthritis that which be easily used in predictive numerical simulations of the hip joint behavior. To quantify the effects of osteoarthritis (OA) on the viscoelastic behavior of human articular cartilage, samples were obtained from the hip arthroplasty due to femoral neck fracture (normal cartilage) or advanced coxarthrosis (OA cartilage). Experimental data were obtained from instrumented indentation tests on unfrozen femoral cartilage collected and studied in the day following the prosthetic hip surgery pose. By using an inverse method coupled with a numerical modeling (FEM) of all experimental data of the indentation tests, the viscoelastic properties of the two states were quantified. Mean values of viscoelastic parameters were significantly lower for OA cartilage than normal (instantaneous and relaxed tension moduli, viscosity coefficient). Based on the results and in the thermodynamic framework, a constitutive viscoelastic model taking into account the degree of osteoarthritis as an internal variable of damage is proposed. The isotropic phenomenological viscoelastic model including degradation provides an accurate prediction of the mechanical response of the normal human cartilage and OA cartilage with advanced coxarthrosis but should be further validated for intermediate degrees of osteoarthritis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Design and Implementation of a Quadruped Bionic Robot Based on Virtual Prototype Technology
NASA Astrophysics Data System (ADS)
Wang, Li
2017-10-01
Design out a quadruped bionic robot with nine degrees of freedom. Conduct virtual assembly and trotting gait simulation on the robot by using NX software. Present the angular velocity and angular displacement curves of the diagonal two legs’ hip joints and knee joints, thus to instruct the practical assemble and control of the robot. The fact that the movement effect of the physical model is consistent with the simulation verifies the validity and practicability of virtual assembly and motion simulation. both.
Messori, Andrea; Trippoli, Sabrina; Marinai, Claudio
2017-01-01
Objectives In most European countries, innovative medical devices are not managed according to cost–utility methods, the reason being that national agencies do not generally evaluate these products. The objective of our study was to investigate the cost-utility profile of prostheses for hip replacement and to calculate a value-based score to be used in the process of procurement and tendering for these devices. Methods The first phase of our study was aimed at retrieving the studies reporting the values of QALYs, direct cost, and net monetary benefit (NMB) from patients undergoing total hip arthroplasty (THA) with different brands of hip prosthesis. The second phase was aimed at calculating, on the basis of the results of cost–utility analysis, a tender score for each device (defined according to standard tendering equations and adapted to a 0–100 scale). This allowed us to determine the ranking of each device in the simulated tender. Results We identified a single study as the source of information for our analysis. Nine device brands (cemented, cementless, or hybrid) were evaluated. The cemented prosthesis Exeter V40/Elite Plus Ogee, the cementless device Taperloc/Exceed, and the hybrid device Exeter V40/Trident had the highest NMB (£152 877, £156 356, and £156 210, respectively) and the best value-based tender score. Conclusions The incorporation of value-based criteria in the procurement process can contribute to optimising the value for money for THA devices. According to the approach described herein, the acquisition of these devices does not necessarily converge on the product with the lowest cost; in fact, more costly devices should be preferred when their increased cost is offset by the monetary value of the increased clinical benefit. PMID:29259062
Cronin, Baker; Johnson, Samuel T.; Chang, Eunwook; Pollard, Christine D.; Norcross, Marc F.
2016-01-01
Background: The relationships between hip abductor and extensor strength and frontal plane hip and knee motions that are associated with anterior cruciate ligament injury risk are equivocal. However, previous research on these relationships has evaluated relatively low-level movement tasks and peak torque rather than a time-critical strength measure such as the rate of torque development (RTD). Hypothesis: Females with greater hip abduction and extension RTD would exhibit lesser frontal plane hip and knee motion during a single-leg jump-cutting task. Study Design: Descriptive laboratory study. Methods: Forty recreationally active females performed maximal isometric contractions and single-leg jump-cuts. From recorded torque data, hip extension and abduction RTD was calculated from torque onset to 200 ms after onset. Three-dimensional motion analysis was used to quantify frontal plane hip and knee kinematics during the movement task. For each RTD measure, jump-cut biomechanics were compared between participants in the highest (high) and lowest (low) RTD tertiles. Results: No differences in frontal plane hip and knee kinematics were identified between high and low hip abduction RTD groups. However, those in the high hip extension RTD group exhibited lower hip adduction (high, 3.8° ± 3.0°; low, 6.5° ± 3.0°; P = .019) and knee valgus (high, –2.5° ± 2.3°; low, –4.4° ± 3.2°; P = .046) displacements during the jump-cut. Conclusion: In movements such as cutting that are performed with the hip in a relatively abducted and flexed position, the ability of the gluteus medius to control hip adduction may be compromised. However, the gluteus maximus, functioning as a hip abductor, may take on a pivotal role in controlling hip adduction and knee valgus motion during these types of tasks. Clinical Relevance: Training with a specific emphasis on increasing explosive strength of the hip extensors may be a means through which to improve frontal plane hip and knee control during high-risk maneuvers such as cutting. PMID:27104207
Yeh, Hui-Fang; Hsu, Yao-Chun; Clinciu, Daniel L; Tung, Heng-Hsin; Yen, Yung-Chieh; Kuo, Hung-Chang
2018-06-03
The purpose of this study is to identify whether depression and other associated factors in stroke are related to subsequent hip fracture. There are very few studies that focus on depression and demographic impact on subsequent hip fracture after a stroke. This a retrospective cohort study design. The Taiwan Longitudinal Health Insurance Database between 1997 and 2010 was used. Two stroke patient cohorts were analysed: (1) depression within 1 year after newly diagnosed strokes; (2) without depression within 1 year after newly diagnosed strokes. Demographic characteristics, comorbidities, and hip fracture were compared using the Fine and Gray regression model for subdistribution hazard ratios. Patients with depression showed a higher risk of hip fracture (95% CI, 0.99-1.66). Depression was associated with increased risk of hip fracture for patients below 50 years old (95% CI, 1.45-7.34). Comorbidities and gender showed no significant correlation with hip fracture risk in the depressed or nondepressed groups. Poststroke depression was a significant contributor to hip fracture in patients who suffered strokes and had more negative impact on the younger population, regardless of the gender and presence of comorbidities. © 2018 John Wiley & Sons Australia, Ltd.
Kim, Soo-Yong; Kang, Min-Hyeok; Kim, Eui-Ryong; Jung, In-Gui; Seo, Eun-Young; Oh, Jae-Seop
2016-10-01
The aim of this study was to investigate the effects of additional isometric hip adduction during the plank exercise on the abdominal muscles. Twenty healthy young men participated in this study. Surface electromyography (EMG) was used to monitor the activity of the bilateral rectus abdominis (RA), the internal oblique (IO), and the external oblique (EO) muscles. The participants performed three types of plank exercise; the standard plank exercise, the plank exercise with bilateral isometric hip adduction, and the plank exercise with unilateral isometric hip adduction. All abdominal muscle activity was significantly increased during the plank exercise combined with the bilateral and unilateral isometric hip adduction compared with the standard plank exercise (p<0.05). Bilateral IO, EO, and left RA muscle activity was significantly increased during the unilateral isometric hip adduction compared with the bilateral isometric hip adduction (p<0.05). These findings suggest that additional isometric hip adduction during the plank exercise could be a useful method to enhance abdominal muscle activity. In particular, the unilateral isometric hip adduction is a more beneficial exercise than the bilateral isometric hip adduction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Active shape modeling of the hip in the prediction of incident hip fracture.
Baker-LePain, Julie C; Luker, Kali R; Lynch, John A; Parimi, Neeta; Nevitt, Michael C; Lane, Nancy E
2011-03-01
The objective of this study was to evaluate right proximal femur shape as a risk factor for incident hip fracture using active shape modeling (ASM). A nested case-control study of white women 65 years of age and older enrolled in the Study of Osteoporotic Fractures (SOF) was performed. Subjects (n = 168) were randomly selected from study participants who experienced hip fracture during the follow-up period (mean 8.3 years). Controls (n = 231) had no fracture during follow-up. Subjects with baseline radiographic hip osteoarthritis were excluded. ASM of digitized right hip radiographs generated 10 independent modes of variation in proximal femur shape that together accounted for 95% of the variance in proximal femur shape. The association of ASM modes with incident hip fracture was analyzed by logistic regression. Together, the 10 ASM modes demonstrated good discrimination of incident hip fracture. In models controlling for age and body mass index (BMI), the area under receiver operating characteristic (AUROC) curve for hip shape was 0.813, 95% confidence interval (CI) 0.771-0.854 compared with models containing femoral neck bone mineral density (AUROC = 0.675, 95% CI 0.620-0.730), intertrochanteric bone mineral density (AUROC = 0.645, 95% CI 0.589-0.701), femoral neck length (AUROC = 0.631, 95% CI 0.573-0.690), or femoral neck width (AUROC = 0.633, 95% CI 0.574-0.691). The accuracy of fracture discrimination was improved by combining ASM modes with femoral neck bone mineral density (AUROC = 0.835, 95% CI 0.795-0.875) or with intertrochanteric bone mineral density (AUROC = 0.834, 95% CI 0.794-0.875). Hips with positive standard deviations of ASM mode 4 had the highest risk of incident hip fracture (odds ratio = 2.48, 95% CI 1.68-3.31, p < .001). We conclude that variations in the relative size of the femoral head and neck are important determinants of incident hip fracture. The addition of hip shape to fracture-prediction tools may improve the risk assessment for osteoporotic hip fractures. Copyright © 2011 American Society for Bone and Mineral Research.
The Prevalence and Treatment of Hip Dysplasia in Prader-Willi Syndrome (PWS).
Trizno, Anastasiya A; Jones, Alexander S; Carry, Patrick M; Georgopoulos, Gaia
2018-03-01
Prader-Willi syndrome (PWS) is a genetic disorder with multisystem involvement. There are a number of associated orthopaedic manifestations, the most recognized of which is scoliosis. The aim of this study was to assess the prevalence of hip dysplasia and to investigate its treatment in patients with PWS. Following IRB approval, all patients seen at our institution's Prader-Willi multidisciplinary clinic were retrospectively reviewed. Only patients with an ultrasound, anteroposterior (AP) spine, AP abdomen, AP hip radiograph, and/or skeletal survey were included in the study. The presence of hip dysplasia was determined based on ultrasonographic and/or radiographic measurements performed by a single fellowship trained pediatric orthopaedic surgeon. A multivariable logistic regression analysis was used to test the association between patient demographics and the prevalence of hip dysplasia. Age at diagnosis, treatment type, and outcomes were recorded for patients that underwent treatment for hip dysplasia. Hip dysplasia was identified in 30% (27/90) of the patient population. Two of the 27 patients (7.4%) had normal films but had a history of resolved hip dysplasia. Prevalence was not associated with sex (P=0.7072), genetic subtype (P=0.5504), race (P=0.8537), ethnicity (P=0.2191), or duration of follow-up (P=0.4421). Eight of the 27 patients (30%) underwent hip treatment by Pavlik harness (2/8), Pavlik harness and closed reduction (1/8), closed reduction (3/8), open reduction (1/8), and unspecified hip surgery (1/8). The mean age at diagnosis was 2 months for the patients that were successfully treated for hip dysplasia (3/8) and 12 months for those who had residual dysplasia following the treatment (5/8). Our study demonstrates a higher prevalence of hip dysplasia in patients with PWS than previously documented. The age at which hip dysplasia develops remains unknown; therefore, we recommend an ultrasound screening for all infants with PWS at 6 weeks of age and subsequent radiographic studies at 1, 2, 5, 10, and 15 years of age to allow for early diagnosis and intervention. Level III-retrospective comparative study.
Eitzen, Ingrid; Fernandes, Linda; Nordsletten, Lars; Risberg, May Arna
2012-12-20
Existent biomechanical studies on hip osteoarthritic gait have primarily focused on the end stage of disease. Consequently, there is no clear consensus on which specific gait parameters are of most relevance for hip osteoarthritis patients with mild to moderate symptoms. The purpose of this study was to explore sagittal plane gait characteristics during the stance phase of gait in hip osteoarthritis patients not eligible for hip replacement surgery. First, compared to healthy controls, and second, when categorized into two subgroups of radiographic severity defined from a minimal joint space of ≤/>2 mm. Sagittal plane kinematics and kinetics of the hip, knee and ankle joint were calculated for total joint excursion throughout the stance phase, as well as from the specific events initial contact, midstance, peak hip extension and toe-off following 3D gait analysis. In addition, the Western Ontario and McMaster Universities Osteoarthritis Index, passive hip range of motion, and isokinetic muscle strength of hip and knee flexion and extension were included as secondary outcomes. Data were checked for normality and differences evaluated with the independent Student's t-test, Welch's t-test and the independent Mann-Whitney U-test. A binary logistic regression model was used in order to control for velocity in key variables. Fourty-eight hip osteoarthritis patients and 22 controls were included in the final material. The patients walked significantly slower than the controls (p=0.002), revealed significantly reduced joint excursions of the hip (p<0.001) and knee (p=0.011), and a reduced hip flexion moment at midstance and peak hip extension (p<0.001). Differences were primarily manifested during the latter 50% of stance, and were persistent when controlling for velocity. Subgroup analyses of patients with minimal joint space ≤/>2 mm suggested that the observed deviations were more pronounced in patients with greater radiographic severity. The biomechanical differences were, however, not reflected in self-reported symptoms or function. Reduced gait velocity, reduced sagittal plane joint excursion, and a reduced hip flexion moment in the late stance phase of gait were found to be evident already in hip osteoarthritis patients with mild to moderate symptoms, not eligible for total hip replacement. Consequently, these variables should be considered as key features in studies regarding hip osteoarthritic gait at all stages of disease. Subgroup analyses of patients with different levels of radiographic OA further generated the hypothesis that the observed characteristics were more pronounced in patients with a minimal joint space ≤2 mm.
2010-01-01
Background Vitamin D supplementation for fracture prevention is widespread despite conflicting interpretation of relevant randomised controlled trial (RCT) evidence. This study summarises quantitatively the current evidence from RCTs and observational studies regarding vitamin D, parathyroid hormone (PTH) and hip fracture risk. Methods We undertook separate meta-analyses of RCTs examining vitamin D supplementation and hip fracture, and observational studies of serum vitamin D status (25-hydroxyvitamin D (25(OH)D) level), PTH and hip fracture. Results from RCTs were combined using the reported hazard ratios/relative risks (RR). Results from case-control studies were combined using the ratio of 25(OH)D and PTH measurements of hip fracture cases compared with controls. Original published studies of vitamin D, PTH and hip fracture were identified through PubMed and Web of Science databases, searches of reference lists and forward citations of key papers. Results The seven eligible RCTs identified showed no significant difference in hip fracture risk in those randomised to cholecalciferol or ergocalciferol supplementation versus placebo/control (RR = 1.13[95%CI 0.98-1.29]; 801 cases), with no significant difference between trials of <800 IU/day and ≥800 IU/day. The 17 identified case-control studies found 33% lower serum 25(OH)D levels in cases compared to controls, based on 1903 cases. This difference was significantly greater in studies with population-based compared to hospital-based controls (χ21 (heterogeneity) = 51.02, p < 0.001) and significant heterogeneity was present overall (χ216 (heterogeneity) = 137.9, p < 0.001). Serum PTH levels in hip fracture cases did not differ significantly from controls, based on ten case-control studies with 905 cases (χ29 (heterogeneity) = 149.68, p < 0.001). Conclusions Neither higher nor lower dose vitamin D supplementation prevented hip fracture. Randomised and observational data on vitamin D and hip fracture appear to differ. The reason for this is unclear; one possible explanation is uncontrolled confounding in observational studies. Post-fracture PTH levels are unrelated to hip fracture risk. PMID:20540727
Tay, Charison; Khajuria, Ankur; Gupte, Chinmay
2014-01-01
Traditional orthopaedic training has followed an apprenticeship model whereby trainees enhance their skills by operating under guidance. However the introduction of limitations on training hours and shorter training programmes mean that alternative training strategies are required. To perform a literature review on simulation training in arthroscopy and devise a framework that structures different simulation techniques that could be used in arthroscopic training. A systematic search of Medline, Embase, Google Scholar and the Cochrane Databases were performed. Search terms included "virtual reality OR simulator OR simulation" and "arthroscopy OR arthroscopic". 14 studies evaluating simulators in knee, shoulder and hip arthroplasty were included. The majority of the studies demonstrated construct and transference validity but only one showed concurrent validity. More studies are required to assess its potential as a training and assessment tool, skills transference between simulators and to determine the extent of skills decay from prolonged delays in training. We also devised a "ladder of arthroscopic simulation" that provides a competency-based framework to implement different simulation strategies. The incorporation of simulation into an orthopaedic curriculum will depend on a coordinated approach between many bodies. But the successful integration of simulators in other areas of surgery supports a possible role for simulation in advancing orthopaedic education. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Adult acetabulo - pelvic parameters in Turkish society: A descriptive radiological study.
Aydin, Murat; Kircil, Cihan; Polat, Onur; Arikan, Murat; Erdemli, Bülent
2016-12-01
The aim of this study was to measure the prevalences of the acetabular index, collodiaphyseal angle, CE angle, articulo-trochanteric distance, cross-over sign and posterior wall sign in healthy Turkish people, in order to shed light on the production of orthopedic medical products. In this study, both hips (a total of 3960 hips) of 1980 individuals (1178 males, 802 females) from nine different cities between the ages of 18 and 65 years were measured and statistically analyzed. The right articulo-trochanteric distance of all participants was 19.67 ± 4.52 mm and the left articulo-trochanteric distance was 19.10 ± 4.58 mm. The CE angle was 35.11°±7.41° in the right hip and 35.37°±6.76° in the left hip. The acetabular index was 37.58°±5.30° in the right hip and 37.80°±4.82° in the left hip. The collodiaphyseal angle was 138.60°±8.27° in the right and 137.84°±8.01° in the left hip. The prevalence of cross-over sign in the right hip was 6.46% and 6.66% for the left hip. The prevalence of posterior wall sign was 4.24% for the right hip and 4.19% for the left hip. This study has provided prevalence values of cross-over sign, posterior wall sign, acetabular index, collodiaphyseal angle, CE angle and articulo-trochanteric distances of a healthy Turkish population between the ages of 18 and 65 years. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Ayeni, Olufemi R; Kowalczuk, Marcin; Farag, Jordan; Farrokhyar, Forough; Chu, Raymond; Bedi, Asheesh; Willits, Kevin; Bhandari, Mohit
2014-01-01
There has been a noted increase in the diagnosis and reporting of sporting hip injuries and conditions in the medical literature but reporting at the minor hockey level is unknown. The purpose of this study is to investigate the trend of reporting hip injuries in amateur ice hockey players in Canada with a focus on injury type and mechanism. A retrospective review of the Hockey Canada insurance database was performed and data on ice hockey hip injuries reported between January 2005 and June 2011 were collected. The study population included all male hockey players from Peewee (aged 11-12 years) to Senior (aged 20+ years) participating in amateur level competition sanctioned by Hockey Canada. Reported cases of ice hockey hip injuries were analyzed according to age, mechanism of injury, and injury subtype. Annual injury reporting rates were determined and using a linear regression analysis trended to determine the change in ice hockey hip injury reporting rate over time. One hundred and six cases of ice hockey-related hip injuries were reported in total. The majority of injuries (75.5%) occurred in players aged 15-20 years playing at the Junior level. Most injuries were caused by a noncontact mechanism (40.6%) and strains were the most common subtype (50.0%). From 2005 to 2010, the number of reported hip injuries increased by 5.31 cases per year and the rate of reported hip injury per 1,000 registered players increased by 0.02 cases annually. Reporting of hip injuries in amateur ice hockey players is increasing. A more accurate injury reporting system is critical for future epidemiologic studies to accurately document the rate and mechanism of hip injury in amateur ice hockey players.
Gnudi, S; Sitta, E; Pignotti, E
2012-08-01
To compare hip fracture incidence in post-menopausal females who were differently stratified for the fracture risk according to bone mineral density and proximal femur geometry. In a 5 year follow-up study, the hip fracture incidence in 729 post-menopausal females (45 of whom suffered from incident hip fracture) was assessed and compared. Forward logistic regression was used to select independent predictors of hip fracture risk, including age, age at menopause, height, weight, femoral neck bone mineral density (FNBMD), neck-shaft angle (NSA), hip axis length, femoral neck diameter and femoral shaft diameter as covariates. Fracture incidence was then calculated for the categories of young/old age, high/low FNBMD and wide/narrow NSA, which were obtained by dichotomising each hip fracture independent predictor at the value best separating females with and without a hip fracture. The hip fracture incidence of the whole cohort was significantly higher in females with a wide NSA (8.52%) than in those with a narrow NSA (3.51%). The combination of wide NSA and low FNBMD had the highest hip fracture incidence in the whole cohort (17.61%) and each age category. The combinations of narrow/wide NSA with low/high FNBMD, respectively, gave a significantly higher fracture incidence in older than in younger women, whereas women with a combined wide NSA and low FNBMD had no significantly different fracture incidence in young (14.60%) or old age (21.62%). Our study showed that NSA is effective at predicting the hip fracture risk and that the detection in early post-menopause of a wide NSA together with a low FNBMD should identify females at high probability of incident hip fracture.
Gnudi, S; Sitta, E; Pignotti, E
2012-01-01
Objective To compare hip fracture incidence in post-menopausal females who were differently stratified for the fracture risk according to bone mineral density and proximal femur geometry. Methods In a 5 year follow-up study, the hip fracture incidence in 729 post-menopausal females (45 of whom suffered from incident hip fracture) was assessed and compared. Forward logistic regression was used to select independent predictors of hip fracture risk, including age, age at menopause, height, weight, femoral neck bone mineral density (FNBMD), neck–shaft angle (NSA), hip axis length, femoral neck diameter and femoral shaft diameter as covariates. Fracture incidence was then calculated for the categories of young/old age, high/low FNBMD and wide/narrow NSA, which were obtained by dichotomising each hip fracture independent predictor at the value best separating females with and without a hip fracture. Results The hip fracture incidence of the whole cohort was significantly higher in females with a wide NSA (8.52%) than in those with a narrow NSA (3.51%). The combination of wide NSA and low FNBMD had the highest hip fracture incidence in the whole cohort (17.61%) and each age category. The combinations of narrow/wide NSA with low/high FNBMD, respectively, gave a significantly higher fracture incidence in older than in younger women, whereas women with a combined wide NSA and low FNBMD had no significantly different fracture incidence in young (14.60%) or old age (21.62%). Conclusion Our study showed that NSA is effective at predicting the hip fracture risk and that the detection in early post-menopause of a wide NSA together with a low FNBMD should identify females at high probability of incident hip fracture. PMID:22096224
Anthropometry, physical activity and hip fractures in the elderly.
Benetou, Vassiliki; Orfanos, Philippos; Benetos, Ioannis S; Pala, Valeria; Evangelista, Alberto; Frasca, Graziella; Giurdanella, Maria Concetta; Peeters, Petra H M; van der Schouw, Ivonne T; Rohrmann, Sabine; Linseisen, Jakob; Boeing, Heiner; Weikert, Cornelia; Pettersson, Ulrika; Van Guelpen, Bethany; Bueno de Mesquita, H Bas; Altzibar, Jone; Boffetta, Paolo; Trichopoulou, Antonia
2011-02-01
Hip fractures constitute a major and growing public health problem amongst the elderly worldwide. We examined the association of anthropometry and physical activity with hip fracture incidence in a cohort of elderly Europeans, participants in the European Prospective Investigation into Cancer and nutrition (EPIC) study. The study population consisted of 27 982 volunteers (10 553 men and 17 429 women) aged 60 years and above from five European countries. Information on anthropometry, physical activity, medical history and other characteristics was collected at baseline. During a median follow-up of 8 years, 261 incident hip fractures (203 women and 58 men) were recorded. Data were analysed through Cox proportional hazard regression with adjustment for potential confounders. A higher body mass index (BMI) was associated with lower hip fracture risk (hazard ratio (HR)per increasing sex-specific-quintile: 0.85, 95% confidence interval (95% CI): 0.77–0.94). Body height was associated with increased hip fracture risk (HR per 5 cm: 1.13, 95% CI: 1.01–1.25). Waist-to-hip ratio was not related to hip fracture risk. Increasing levels of leisure-time physical activity were related to lower risk (HR per increasing tertile: 0.84, 95% CI: 0.70–0.99, p for trend: 0.039). In a prospective cohort study of elderly Europeans, we found evidence that high body stature increased and high BMI decreased the incidence of hip fractures. After adjustment for BMI,waist to-hip ratio was not associated with hip fracture risk. Leisure-time physical activity appears to play a beneficial role in the prevention of hip fractures. 2010 Elsevier Ltd. All rights reserved.
Whiteside, David; Deneweth, Jessica M; Bedi, Asheesh; Zernicke, Ronald F; Goulet, Grant C
2015-07-01
Femoroacetabular impingement (FAI) is particularly prevalent in ice hockey. The butterfly goalie technique is thought to involve extreme ranges of hip motion that may predispose goaltenders to FAI. To quantify hip mechanics during 3 common goaltender movements and interpret their relevance to the development of FAI. Descriptive laboratory study. Fourteen collegiate and professional goaltenders performed skating, butterfly save, and recovery movements on the ice. Hip mechanics were compared across the 3 movements. The butterfly did not exhibit the greatest range of hip motion in any of the 3 planes. Internal rotation was the only hip motion that appeared close to terminal in this study. When subjects decelerated during skating—shaving the blade of their skate across the surface of the ice—the magnitude of peak hip internal rotation was 54% greater than in the butterfly and 265% greater than in the recovery. No movement involved levels of concomitant flexion, adduction, and internal rotation that resembled the traditional impingement (FADIR) test. The magnitude of internal rotation was the most extreme planar hip motion (relative to end-range) recorded in this study (namely during decelerating) and appeared to differentiate this cohort from other athletic populations. Consequently, repetitive end-range hip internal rotation may be the primary precursor to symptomatic FAI in hockey goaltenders and provides the most plausible account for the high incidence of FAI in these athletes. Resection techniques should, therefore, focus on enhancing internal rotation in goaltenders, compared with flexion and adduction. While the butterfly posture can require significant levels of hip motion, recovering from a save and, in particular, decelerating during skating are also demanding on goaltenders' hip joints. Therefore, it appears critical to consider and accommodate a variety of sport-specific hip postures to comprehensively diagnose, treat, and rehabilitate FAI. © 2015 The Author(s).
Yeung, Marco; Memon, Muzammil; Simunovic, Nicole; Belzile, Etienne; Philippon, Marc J; Ayeni, Olufemi R
2016-06-01
Gross hip instability is a rare complication after hip arthroscopy, and there is limited literature surrounding this topic. This systematic review investigates cases of gross hip instability after arthroscopy and discusses the risk factors associated with this complication. A systematic search was performed in duplicate for studies investigating gross hip instability after hip arthroscopy up to October 2015. Study parameters including sample size, mechanism and type of dislocation, surgical procedure details, patient characteristics, postoperative rehabilitation protocol, and level of evidence were analyzed. The systematic review identified 9 case reports investigating gross hip instability after hip arthroscopy (10 patients). Anterior dislocation occurred in 66.7% of patients, and most injuries occurred with a low-energy mechanism. Common surgical factors cited included unrepaired capsulotomy (77.8%) and iliopsoas release (33.3%), whereas patient factors included female gender (77.8%), acetabular dysplasia (22.2%), and general ligamentous laxity (11.1%). Postoperative restrictions and protocols were variable and inconsistently reported, and their relation to post-arthroscopy instability was difficult to ascertain. This systematic review discussed various patient, surgical, and postoperative risk factors of gross hip instability after arthroscopy. Patient characteristics such as female gender, hip dysplasia, and ligamentous laxity may be risk factors for post-arthroscopy dislocation. Similarly, surgical risk factors for iatrogenic hip instability may include unrepaired capsulotomies and iliopsoas debridement, although the role of capsular closure in iatrogenic instability is not clear. The influences of postoperative restrictions and protocols on dislocation are also unclear in the current literature. Surgeons should be cognizant of these risk factors when performing hip arthroscopy and be mindful that these factors appear to occur in combination. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Kemp, Joanne L; Schache, Anthony G; Makdissi, Michael; Sims, Kevin J; Crossley, Kay M
2013-07-01
This study investigated tests of hip muscle strength and functional performance. The specific objectives were to: (i) establish intra- and inter-rater reliability; (ii) compare differences between dominant and non-dominant limbs; (iii) compare agonist and antagonist muscle strength ratios; (iv) compare differences between genders; and (v) examine relationships between hip muscle strength, baseline measures and functional performance. Reliability study and cross-sectional analysis of hip strength and functional performance. In healthy adults aged 18-50years, normalised hip muscle peak torque and functional performance were evaluated to: (i) establish intra-rater and inter-rater reliability; (ii) analyse differences between limbs, between antagonistic muscle groups and genders; and (iii) associations between strength and functional performance. Excellent reliability (intra-rater ICC=0.77-0.96; inter-rater ICC=0.82-0.95) was observed. No difference existed between dominant and non-dominant limbs. Differences in strength existed between antagonistic pairs of muscles: hip abduction was greater than adduction (p<0.001) and hip ER was greater than IR (p<0.001). Men had greater ER strength (p=0.006) and hop for distance (p<0.001) than women. Strong associations were observed between measures of hip muscle strength (except hip flexion) and age, height, and functional performance. Deficits in hip muscle strength or functional performance may influence hip pain. In order to provide targeted rehabilitation programmes to address patient-specific impairments, and determine when individuals are ready to return to physical activity, clinicians are increasingly utilising tests of hip strength and functional performance. This study provides a battery of reliable, clinically applicable tests which can be used for these purposes. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Lecerf, G; Fessy, M H; Philippot, R; Massin, P; Giraud, F; Flecher, X; Girard, J; Mertl, P; Marchetti, E; Stindel, E
2009-05-01
BACKGROUND OBJECTIVE: Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure and the true effect of offset modifications. This article is a collection of independent anatomic, radiological and clinical works, which purpose is to assess knowledge of the implications of femoral offset for preoperative templating and total hip arthroplasty. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne - flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset measurement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modular femoral neck. This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 degrees) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. Level IV: Retrospective or historical series.
NASA Astrophysics Data System (ADS)
Jung, Duk-Young; Kang, Yu-Bong; Tsutsumi, Sadami; Nakai, Ryusuke; Ikeuchi, Ken; Sekel, Ron
In this study, we simulated a wide cortex separation from a cementless hip prosthesis using the bone resorption remodeling method that is based on the generation of high compressive stress around the distal cortical bone. Thereafter, we estimated the effect on late migration quantities of the hip prosthesis produced by the interface state arising from bone ingrowth. This was accomplished using cortical bone remodeling over a long period of time. Two-dimensional natural hip and implanted hip FEM models were constructed with each of the following interface statements between the bone and prosthesis: (1) non-fixation, (2) proximal 1/3, (3) proximal 2/3 and (4) full-fixation. The fixation interfaces in the fully and partially porous coated regions were rigidly fixed by bony ingrowth. The non-fixation model was constructed as a critical situation, with the fibrous or bony tissue not integrated at all into the implant surface. The daily load history was generated using the three loading cases of a one-legged stance as well as abduction and adduction motions. With the natural hip and one-legged stance, the peak compressive principal stresses were found to be under the criteria value for causing bone resorption, while no implant movement occurred. The migration magnitude of the stem of the proximal 1/3 fixation model with adduction motion was much higher, reaching 6%, 11%and 21%greater than those of the non-fixation, proximal 2/3 fixation and all-fixation models, respectively. The full-fixation model showed the lowest compressive principal stress and implant movement. Thus, we concluded that the late loosening and subsequent movement of the stem in the long term could be estimated with the cortical bone remodeling method based on a high compressive stress at the bone-implant interface. The change caused at the bone-prosthesis interface by bony or fibrous tissue ingrowth constituted the major factor in determining the extent of cortical bone resorption occurring with clinical loosening and subsequent implant movement.
ERIC Educational Resources Information Center
Buchanan, Ian P.
2013-01-01
Using a critical race lens, this narrative study employs a focus group design to explore the intersections between black males, hip hop culture and schooling experiences. To provide a sociocultural grounding, this study first reviews the research literature around hip hop culture.s sociocultural development and its impact as a culture force that…
Abnormal hip physical examination findings in asymptomatic female soccer athletes
Hunt, Devyani; Rho, Monica; Yemm, Ted; Fong, Kathryn; Brophy, Robert H.
2016-01-01
Purpose Examination of the hip provides information regarding risk for pre-arthritic hip disorders, knee injuries, and low back pain. The purpose of this study was to report a hip screening examination of asymptomatic female soccer athletes and to test the hypothesis that these findings vary by competition experience. Methods Asymptomatic females from a youth soccer club, a college, and a professional team were evaluated. Passive hip range of motion, hip abduction strength, and hip provocative tests were assessed. Data were compared for the grade/middle school, high school, college, and professional athletes. Results One hundred and seventy-two athletes with a mean age of 16.7 ± 5 years (range 10–30) participated. Professional athletes had less flexion (HF) for both hips (p < 0.0001) and less internal rotation (IR) for the preferred kicking leg (p < 0.05) compared to all other groups. Grade/middle school athletes had more external rotation in both hips as compared to all other groups (p < 0.0001). For the preferred kicking leg, collegiate athletes had less hip abduction strength as compared to other groups (p < 0.01). Positive provocative hip tests were found in 22 % of all players and 36 % of the professionals. In professionals, a positive provocative test was associated with ipsilateral decreased HF (p = 0.04). Conclusion Asymptomatic elite female soccer athletes with the most competition experience had less bilateral hip flexion and preferred kicking leg IR than less-experienced athletes. Positive provocative hip tests were found in 22 % of athletes. Future studies are needed to show whether these findings link to risk for intra-articular hip or lumbar spine and knee disorders. Level of evidence III. PMID:24150125
Cashman, Glenn E; Mortenson, W Ben; Gilbart, Michael K
2014-08-01
Single-subject research design using 4 consecutive patients. To assess whether treatment using soft tissue therapy (ART or Active Release Technique), stretching, and strengthening of the hip abductors, hip external rotators, and tensor fascia latae muscles reduces pain and improves self-reported hip function in patients with acetabular labral tears who also have posterolateral hip pain of suspected myofascial origin. Acetabular labral tears cause pain in some but not all patients. Pain commonly presents anteriorly but may also present posteriorly and laterally. The standard of care is arthroscopic repair, which helps many but not all patients. It is possible that these patients may present with extra-articular contributions to their pain, such as myofascial pain, making their clinical presentation more complex. No previous study has assessed soft tissue therapy as a treatment option for this subset of patients. This A-B-A design used repeated measures of the Hip Outcome Score and visual analog scale for pain. Four patients were treated for 6 to 8 weeks, using a combination of soft tissue therapy, stretching, and strengthening for the hip abductors, external rotators, and tensor fascia latae. Data were assessed visually, statistically, and by comparing mean differences before and after intervention. All 4 patients experienced both statistically significant and clinically meaningful improvement in posterolateral hip pain and hip-related function. Three patients also experienced reduction in anteromedial hip pain. Myofascial hip pain may contribute to hip-related symptoms and disability in patients with acetabular labral tears and posterolateral hip pain. These patients may benefit from soft tissue therapy combined with stretching and strengthening exercises targeting the hip abductors, tensor fascia latae, and hip external rotator muscles. Level of Evidence Therapy, level 4.
Educational Inequalities in Post-Hip Fracture Mortality: A NOREPOS Study.
Omsland, Tone K; Eisman, John A; Naess, Øyvind; Center, Jacqueline R; Gjesdal, Clara G; Tell, Grethe S; Emaus, Nina; Meyer, Haakon E; Søgaard, Anne Johanne; Holvik, Kristin; Schei, Berit; Forsmo, Siri; Magnus, Jeanette H
2015-12-01
Hip fractures are associated with high excess mortality. Education is an important determinant of health, but little is known about educational inequalities in post-hip fracture mortality. Our objective was to investigate educational inequalities in post-hip fracture mortality and to examine whether comorbidity or family composition could explain any association. We conducted a register-based population study of Norwegians aged 50 years and older from 2002 to 2010. We measured total mortality according to educational attainment in 56,269 hip fracture patients (NORHip) and in the general Norwegian population. Both absolute and relative educational inequalities in mortality in people with and without hip fracture were compared. There was an educational gradient in post-hip fracture mortality in both sexes. Compared with those with primary education only, the age-adjusted relative risk (RR) of mortality in hip fracture patients with tertiary education was 0.82 (95% confidence interval [CI] 0.77-0.87) in men and 0.79 (95% CI 0.75-0.84) in women. Additional adjustments for Charlson comorbidity index, marital status, and number of children did not materially change the estimates. Regardless of educational attainment, the 1-year age-adjusted mortality was three- to fivefold higher in hip fracture patients compared with peers in the general population without fracture. The absolute differences in 1-year mortality according to educational attainment were considerably larger in hip fracture patients than in the population without hip fracture. Absolute educational inequalities in mortality were higher after hip fracture compared with the general population without hip fracture and were not mediated by comorbidity or family composition. Investigation of other possible mediating factors might help to identify new targets for interventions, based on lower educational attainment, to reduce post-hip fracture mortality. © 2015 American Society for Bone and Mineral Research.
Kheirollahi, Hossein
2015-01-01
Accurate assessment of hip fracture risk is very important to prevent hip fracture and to monitor the effect of a treatment. A subject-specific QCT-based finite element model was constructed to assess hip fracture risk at the critical locations of femur during the single-leg stance and the sideways fall. The aim of this study was to improve the prediction of hip fracture risk by introducing a novel failure criterion to more accurately describe bone failure mechanism. Hip fracture risk index was defined using cross-section strain energy, which is able to integrate information of stresses, strains, and material properties affecting bone failure. It was found that the femoral neck and the intertrochanteric region have higher fracture risk than other parts of the femur, probably owing to the larger content of cancellous bone in these regions. The study results also suggested that women are more prone to hip fracture than men. The findings in this study have a good agreement with those clinical observations reported in the literature. The proposed hip fracture risk index based on strain energy has the potential of more accurate assessment of hip fracture risk. However, experimental validation should be conducted before its clinical applications. PMID:26601105
Khanna, Vickas; Harris, Adam; Farrokhyar, Forough; Choudur, Hema N; Wong, Ivan H
2014-03-01
The purpose of this study was to document and compare the incidence of intra-articular hip pathologic findings identified using arthroscopy versus conventional imaging in patients with acute trauma to the hip. This was a blinded prospective case series study designed to review the incidence of intra-articular pathologic disorders in patients with post-traumatic injury between the ages of 18 and 65 years who were referred to a single surgeon. Injuries included hip dislocation, proximal femur fracture, pelvic ring fracture, acetabular fracture, penetrating injury (gunshot wound), and soft tissue injury. Preoperative radiographs, computed tomographic (CT) scans, or magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) scans (or a combination of these) were obtained. Findings were documented and compared with intraoperative findings. A total of 29 post-traumatic hips were enrolled in this study. Hip arthroscopy identified 17 of 29 hips (59%) as having loose bodies, 11 of 29 (38%) hips as having an intra-articular step deformity, 14 of 29 (49%) hips as having an osteochondral lesion, and 27 of 29 (93%) hips as having a labral tear. Plain radiographs and CT scans yielded low sensitivity when compared with arthroscopy for the identification of loose bodies and step deformities. MRI/MRA comparison with arthroscopic findings suggest that MRI/MRA is an accurate tool for identification of labral tears, because 91% of tears seen on arthroscopy were also identified by MRI/MRA. In 4 hips, however, MRI/MRA failed to identify osteochondral lesions that were subsequently identified by arthroscopy. Traumatic injuries of the hip result in substantial intra-articular pathologic findings, including loose bodies, labral tears, step deformities, and osteochondral lesions. The arthroscope is a powerful tool in identifying these injuries. Plain radiographs and CT scans appear to underestimate the true incidence of loose bodies and step deformities within the joint when compared with hip arthroscopy after a traumatic injury of the hip. Level IV, diagnostic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Validation of a 3D CT method for measurement of linear wear of acetabular cups.
Jedenmalm, Anneli; Nilsson, Fritjof; Noz, Marilyn E; Green, Douglas D; Gedde, Ulf W; Clarke, Ian C; Stark, Andreas; Maguire, Gerald Q; Zeleznik, Michael P; Olivecrona, Henrik
2011-02-01
We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.
Ariza, O; Gilchrist, S; Widmer, R P; Guy, P; Ferguson, S J; Cripton, P A; Helgason, B
2015-01-21
Current screening techniques based on areal bone mineral density (aBMD) measurements are unable to identify the majority of people who sustain hip fractures. Biomechanical examination of such events may help determine what predisposes a hip to be susceptible to fracture. Recently, drop-tower simulations of in-vitro sideways falls have allowed the study of the mechanical response of the proximal human femur at realistic impact speeds. This technique has created an opportunity to validate explicit finite element (FE) models against dynamic test data. This study compared the outcomes of 15 human femoral specimens fractured using a drop tower with complementary specimen-specific explicit FE analysis. Correlation coefficient and root mean square error (RMSE) were found to be moderate for whole bone stiffness comparison (R(2)=0.3476 and 22.85% respectively). No correlation was found between experimentally and computationally predicted peak force, however, energy absorption comparison produced moderate correlation and RMSE (R(2)=0.4781 and 29.14% respectively). By comparing predicted strain maps to high speed video data we demonstrated the ability of the FE models to detect vulnerable portions of the bones. Based on our observations, we conclude that there exists a need to extend the current apparent level material models for bone to cover higher strain rates than previously tested experimentally. Copyright © 2014 Elsevier Ltd. All rights reserved.
Prather, Heidi; Cheng, Abby; Steger-May, Karen; Maheshwari, Vaibhav; VanDillen, Linda
2018-01-01
Relationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA). Less is known about the links of LBP with hip radiographic findings of hip deformity and minimal OA. To describe the incidence of radiographic hip deformity or hip OA; to describe and compare spine- and hip-related pain and function in the subset of patients who were found to have radiographic hip deformity or hip OA; and to compare patients with evidence of radiographic hip deformity or hip OA to patients without hip radiographic findings. Prospective cohort study with cross-sectional design. Tertiary university. A total of 63 patients (40 women, 23 men) with a mean age of 48.5 ± 14 years with LBP and a minimum of one positive provocative hip test. Hip radiographs were assessed by an independent examiner for hip OA and deformity. Comparisons of hip and lumbar spine pain and function were completed for patients with radiographic findings of hip OA or deformity. Moderate to severe hip OA was found in 12 of 60 patients (20.0%). At least one measurement of femoroacetabular impingement (FAI) was found in 14 of 60 patients (23.3%) to 33 of 45 patients (73.3%). At least one measurement of developmental hip dysplasia (DDH) was found in 7 of 60 patients (11.6%) to 11 of 63 patients (17.4%). Greater pain and reduced hip and lumbar spine function were found in the patients with moderate to severe hip OA. Patients with LBP and FAI were found to have significantly greater extremes of pain and reduced lumbar spine function. Links between the hip and the spine affecting pain and function may be found in patients with LBP and hip deformity and before the onset of radiographic hip OA, and may be associated with hip deformity. Further investigation is needed to better understand these links and their potential impact on prognosis and treatment of LBP. II. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
[Is Mapuche ethnicity a risk factor for hip fracture in aged?].
Sapunar, Jorge; Bravo, Paulina; Schneider, Hermann; Jiménez, Marcela
2003-10-01
Ethnic factors are involved in the risk for osteoporosis and hip fracture. To assess the effect of Mapuche ethnicity on the risk of hip fracture. A case control study. Cases were subjects over 55 years of age admitted, during one year, for hip fracture not associated to major trauma or tumors. Controls were randomly chosen from other hospital services and paired for age with cases. The magnitude of the association between ethnicity and hip fracture was expressed as odds ratio in a logistic regression model. In the study period, 156 cases with hip fracture were admitted. The proportion of subjects with Mapuche origin was significantly lower among cases than controls (11.8 and 26.5% respectively, p < 0.001). In the logistic regression model, Mapuche ethnicity was associated with hip fracture with an odds radio of 0.14 (p = 0.03, 95% CI 0.03-0.8). In this sample, Mapuche ethnicity is a protective factor for hip fracture.
Increasing incidence of hip fracture in Chiang Mai, Thailand.
Wongtriratanachai, Prasit; Luevitoonvechkij, Sirichai; Songpatanasilp, Thawee; Sribunditkul, Siripoj; Leerapun, Taninnit; Phadungkiat, Sompant; Rojanasthien, Sattaya
2013-01-01
Hip fracture is a major health problem in Thailand. This study attempted to examine the incidence, related factors, and trends of hip fracture in Chiang Mai, Thailand. All hip fracture data among patients aged 50 yr or older were collected from hospitals in Chiang Mai, Thailand from August 1, 2006 to July 3, 2007. Data from the 1997 Chiang Mai hip fracture study were used for comparison. In the study period, 690 hip fractures were reported: 203 males and 487 females (male to female ratio was 1 to 2.4), with a mean age of 76.7 yr. The estimated cumulative incidence was 181.0 per 100,000, and the adjusted incidence was 253.3 (males: 135.9; females: 367.9). A simple fall was the most common mechanism (79%) of fracture, and 80% of the hip fractures occurred in patients aged 70 yr or older. The highest incidence of hip fracture was observed in patients older than 85 yr (1239). At 6 mo postfracture, most patients (61%) used a walking aid. Compared with the 1997 data, hip fracture incidence had increased by an average of 2% per yr, and the incidence of hip fracture had increased significantly from August 1, 2006 to July 31, 2007, especially in patients older than 75 yr. In patients older than 84 yr, the incidence increased by a factor of 2. Urgent strategies for the prevention and treatment of osteoporosis, and hence hip fracture, are needed. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Ybe, Joel A; Clegg, Mary E; Illingworth, Melissa; Gonzalez, Claire; Niu, Qian
2009-01-01
The interaction between HIP family proteins (HIP1 and HIP12/1R) and clathrin is fundamental to endocytosis. We used circular dichroism (CD) to study the stability of an HIP1 subfragment (aa468-530) that is splayed open. CD thermal melts show HIP1 468-530 is only stable at low temperatures, but this HIP1 fragment contains a structural unit that does not melt out even at 83°C. We then created HIP1 mutants to probe our hypothesis that a short hydrophobic path in the opened region is the binding site for clathrin light chain. We found that the binding of hub/LCb was sensitive to mutating two distantly separated basic residues (K474 and K494). The basic patches marked by K474 and K494 are conserved in HIP12/1R. The lack of conservation in sla2p (S. cerevisiae), HIP1 from D. melanogaster, and HIP1 homolog ZK370.3 from C. elegans implies the binding of HIP1 and HIP1 homologs to clathrin light chain may be different in these organisms.
Ybe, Joel A.; Clegg, Mary E.; Illingworth, Melissa; Gonzalez, Claire; Niu, Qian
2009-01-01
The interaction between HIP family proteins (HIP1 and HIP12/1R) and clathrin is fundamental to endocytosis. We used circular dichroism (CD) to study the stability of an HIP1 subfragment (aa468-530) that is splayed open. CD thermal melts show HIP1 468-530 is only stable at low temperatures, but this HIP1 fragment contains a structural unit that does not melt out even at 83°C. We then created HIP1 mutants to probe our hypothesis that a short hydrophobic path in the opened region is the binding site for clathrin light chain. We found that the binding of hub/LCb was sensitive to mutating two distantly separated basic residues (K474 and K494). The basic patches marked by K474 and K494 are conserved in HIP12/1R. The lack of conservation in sla2p (S. cerevisiae), HIP1 from D. melanogaster, and HIP1 homolog ZK370.3 from C. elegans implies the binding of HIP1 and HIP1 homologs to clathrin light chain may be different in these organisms. PMID:22820750
Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki
2018-06-01
We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.
HiL simulation in biomechanics: a new approach for testing total joint replacements.
Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer
2012-02-01
Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Heiner, Anneliese D.; Lundberg, Hannah J.; Baer, Thomas E.; Pedersen, Douglas R.; Callaghan, John J.; Brown, Thomas D.
2008-01-01
In total joint arthroplasty, third body particle access to the articulating surfaces results in accelerated wear. Hip joint subluxation is an under-recognized means by which third body particles could potentially enter the otherwise closely conforming articular bearing space. The present study was designed to test the hypothesis that, other factors being equal, even occasional events of femoral head subluxation greatly increase the number of third body particles that enter the bearing space and become embedded in the acetabular liner, as compared to level walking cycles alone. Ten metal-on-polyethylene hip joint head-liner pairs were tested in a multi-axis joint motion simulator, with CoCrMo third body particles added to the synovial fluid analog. All component pairs were tested for two hours of level walking; half also were subjected to twenty intermittent subluxation events. The number and location of embedded particles on the acetabular liners were then determined. Subluxation dramatically increased the number of third body particles embedded in the acetabular liners, and it considerably increased the amount of scratch damage on the femoral heads. Since both third body particles and subluxation frequently occur in contemporary total hip arthroplasty, their potent synergy needs to be factored prominently into strategies to minimize wear. PMID:18561936
Cardiorespiratory fitness and hip bone mineral density in women: a 6-year prospective study.
Tucker, Larry A; Nokes, Neil R; Bailey, Bruce W; Lecheminant, James D
2014-10-01
Cross-sectional studies and short term interventions focusing on fitness and bone mineral density (BMD) are common. However, few investigations have studied the effect of fitness on BMD over an extended period of time. The present study was conducted to determine the extent to which cardiorespiratory fitness influences risk of BMD loss at the hip over 6 yr. A prospective cohort design was used with 245 healthy, middle-aged women. Hip BMD was assessed using dual energy x-ray absorptiometry. Calcium and vitamin D were measured using the Block Food Frequency Questionnaire. Menopause status was measured by a questionnaire. Results showed that fit and unfit women experienced similar changes in hip BMD over time. Specifically, unfit women experienced a non-significant 7% increased risk of losing hip BMD compared to their counterparts (RR = 1.07, 95% CI = 0.66, 1.73). Adjusting statistically for differences in age, initial body weight, and hip BMD, weight change, menopause status, calcium and vitamin D intake, and time between assessments had little effect on the relationship. Fitness level did not influence risk of hip BMD loss over time.
Santos, Thiago R T; Oliveira, Bárbara A; Ocarino, Juliana M; Holt, Kenneth G; Fonseca, Sérgio T
2015-01-01
Patellofemoral pain syndrome (PFPS) is characterized by anterior knee pain, which may limit the performance of functional activities. The influence of hip joint motion on the development of this syndrome has already been documented in the literature. In this regard, studies have investigated the effectiveness of hip muscle strengthening in patients with PFPS. The aims of this systematic review were (1) to summarize the literature related to the effects of hip muscle strengthening on pain intensity, muscle strength, and function in individuals with PFPS and (2) to evaluate the methodological quality of the selected studies. A search for randomized controlled clinical trials was conducted using the following databases: Google Scholar, MEDLINE, PEDro, LILACS, and SciELO. The selected studies had to distinguish the effects of hip muscle strengthening in a group of patients with PFPS, as compared to non-intervention or other kinds of intervention, and had to investigate the following outcomes: pain, muscle strength, and function. The methodological quality of the selected studies was analyzed by means of the PEDro scale. Seven studies were selected. These studies demonstrated that hip muscle strengthening was effective in reducing pain. However, the studies disagreed regarding the treatments' ability to improve muscle strength. Improvement in functional capabilities after hip muscle strengthening was found in five studies. Hip muscle strengthening is effective in reducing the intensity of pain and improving functional capabilities in patients with PFPS, despite the lack of evidence for its ability to increase muscle strength.
Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D
2015-06-01
Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.
Hip rotation range of motion in sitting and prone positions in healthy Japanese adults
Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi
2015-01-01
[Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186
The 1963 Hip-Hop Machine: Hip-Hop Pedagogy as Composition.
ERIC Educational Resources Information Center
Rice, Jeff
2003-01-01
Proposes an alternative invention strategy for research-based argumentative writing. Investigates the coincidental usage of the term "whatever" in hip-hop, theory, and composition studies. Presents a "whatever-pedagogy" identified as "hip-hop pedagogy," a writing practice that models itself after digital sampling's…
Create and Publish a Hierarchical Progressive Survey (HiPS)
NASA Astrophysics Data System (ADS)
Fernique, P.; Boch, T.; Pineau, F.; Oberto, A.
2014-05-01
Since 2009, the CDS promotes a method for visualizing based on the HEALPix sky tessellation. This method, called “Hierarchical Progressive Survey" or HiPS, allows one to display a survey progressively. It is particularly suited for all-sky surveys or deep fields. This visualization method is now integrated in several applications, notably Aladin, the SiTools/MIZAR CNES framework, and the recent HTML5 “Aladin Lite". Also, more than one hundred surveys are already available in this view mode. In this article, we will present the progress concerning this method and its recent adaptation to the astronomical catalogs such as the GAIA simulation.
Twist limits for late twisting double somersaults on trampoline.
Yeadon, M R; Hiley, M J
2017-06-14
An angle-driven computer simulation model of aerial movement was used to determine the maximum amount of twist that could be produced in the second somersault of a double somersault on trampoline using asymmetrical movements of the arms and hips. Lower bounds were placed on the durations of arm and hip angle changes based on performances of a world trampoline champion whose inertia parameters were used in the simulations. The limiting movements were identified as the largest possible odd number of half twists for forward somersaulting takeoffs and even number of half twists for backward takeoffs. Simulations of these two limiting movements were found using simulated annealing optimisation to produce the required amounts of somersault, tilt and twist at landing after a flight time of 2.0s. Additional optimisations were then run to seek solutions with the arms less adducted during the twisting phase. It was found that 3½ twists could be produced in the second somersault of a forward piked double somersault with arms abducted 8° from full adduction during the twisting phase and that three twists could be produced in the second somersault of a backward straight double somersault with arms fully adducted to the body. These two movements are at the limits of performance for elite trampolinists. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mun, Frederick; Suh, Seung Woo; Park, Hyun-Joon; Choi, Ahnryul
2015-05-14
Understanding the kinematics of the lumbar spine and hip joints during a golf swing is a basic step for identifying swing-specific factors associated with low back pain. The objective of this study was to examine the kinematic relationship between rotational movement of the lumbar spine and hip joints during a golf swing. Fifteen professional golfers participated in this study with employment of six infrared cameras to record their golf swings. Anatomical reference system of the upper torso, pelvis and thigh segments, and the location of each hip and knee joint were defined by the protocols of the kinematic model of previous studies. Lumbar spine and hip joint rotational angle was calculated utilizing the Euler angle method. Cross-correlation and angle-angle plot was used to examine the degree of kinematic relationship between joints. A fairly strong coupling relationship was shown between the lumbar spine and hip rotational movements with an average correlation of 0.81. Leading hip contribution to overall rotation was markedly high in the early stage of the downswing, while the lumbar spine contributed greater towards the end of the downswing; however, the relative contributions of the trailing hip and lumbar spine were nearly equal during the entire downswing. Most of the professional golfers participated in this study used a similar coordination strategy when moving their hips and lumbar spine during golf swings. The rotation of hips was observed to be more efficient in producing the overall rotation during the downswing when compared to the backswing. These results provide quantitative information to better understand the lumbar spine and hip joint kinematic characteristics of professional golfers. This study will have great potential to be used as a normal control data for the comparison with kinematic information among golfers with low back pain and for further investigation of golf swing-specific factors associated with injury.
The effect of unilateral osteoarthritis of the hip on postural balance disorders.
Truszczyńska, Aleksandra; Trzaskoma, Zbigniew; Białecki, Jerzy; Drzał-Grabiec, Justyna; Dadura, Emilia; Rąpała, Kazimierz; Tarnowski, Adam
2016-11-10
Postural stability is of great importance because imbalances and muscle weakness are significant risk factors for falls experienced by the elderly. Hip arthrosis, which causes pain and gait disorders that affect balance control, is common in the ageing population. The aim of this study was to assess postural stability in patients with unilateral hip arthrosis before total hip arthroplasty. The study population consisted of 52 patients with hip arthrosis (study group) and 47 subjects with no history of clinical symptoms of hip pain. The groups did not differ statistically in terms of age and BMI. Static balance was assessed by conducting a quantitative analysis of balance reaction parameters in a quiet standing position with the eyes open and closed. Analysis of the collected data revealed numerous statistically significant differences between patients with unilateral hip arthrosis before total hip arthoplasty and the asymptomatic group for parameters tested with eyes closed (p<0.05). We observed higher values of total length of centre of pressure (COP), sway path (SP), length of COP path in the medial-lateral plane (SPML), maximal amplitude between the 2 most distant points in the medial-lateral plane (MaxML), mean COP velocity (MV), and mean COP velocity in medial-lateral (MVML) in the study group.
Incidence and Risk Factors of Subsequent Hip Fractures in Korea: Multicenter Study
2014-01-01
This study analyzes the incidence of subsequent hip fractures and its risk factors in the northwestern region of Korea. We analyzed hip fracture patients who visited any of the 5 teaching hospitals in the Bucheon and Incheon area from January 2000 to December 2010. Medical records were reviewed and presence of subsequent hip fractures, alcohol history, marital status, live in solitude, dementia, dizziness, American society of anesthesiologists score, osteoporosis treatment after fracture, body mass index (BMI) and initial bone mineral density were analyzed. The average follow-up period was 12 months (range 1-130 months). A total of 2,546 patients (women 1,770, men 776) who had experienced hip fractures were included. Of these, subsequent hip fractures were found in 233 patients (9.2%) (women 187, men 46). Mean age at the time of the first fracture was 79.2 yr old (range 50-100 yr). The average interval between the first fracture and the subsequent hip fractures was 30.2 months (range 4 days-154 months). In this large-scale, retrospective, multicenter study, overall incidence of subsequent hip fractures is 9.2%. Independent risk factors of subsequent fracture are women, BMI<22 kg/m2, and being unmarried. PMID:25045233
Feng, Dong-Xu; Zhang, Kun; Zhang, Yu-Min; Nian, Yue-Wen; Zhang, Jun; Kang, Xiao-Min; Wu, Shu-Fang; Zhu, Yang-Jun
2016-08-01
Total hip arthroplasty is a reliable therapeutic intervention in patients with ankylosing spondylitis, in whom the aims of surgery are to reduce pain, restore hip function and improve quality of life. The current study is a retrospective analysis of the clinical and radiographic findings in a consecutive series of patients with hip ankylosis associated with severe ankylosing spondylitis who underwent bilateral primary total hip arthroplasty using non-cemented components. From June 2008 to May 2012, total hip arthroplasty was performed on 34 hips in 17 patients with bilateral ankylosis caused by ankylosing spondylitis. The study patients included 13 men and 4 women with a mean age of 24.2 years. The mean duration of disease was 8.3 years and the average duration of hip involvement was 7.6 years. All patients had severe hip pain and dysfunction with bilateral bony ankylosis and no range of motion preoperatively and all underwent bilateral cementless total hip arthroplasty performed by a single surgeon. Joint pain, range of motion (ROM), and Harris hip scores were assessed to evaluate the postoperative results. At a mean follow-up of 31.7 months, all patients had experienced significant clinical improvement in function, ROM, posture and ambulation. At the final follow-up, the mean postoperative flexion ROM was 134.4° compared with 0° preoperatively. Similar improvements were seen in hip abduction, adduction, internal rotation and external rotation. Postoperatively, 23 hips were completely pain-free, six had only occasional discomfort, three mild to moderate pain and two severe pain. The average Harris Hip Score improved from 23.7 preoperatively to 65.8 postoperatively. No stems had loosened at the final follow-up in any patient, nor had any revision surgery been required. Bilateral severe hip ankylosis in patients with ankylosing spondylitis can be treated with cementless bilateral synchronous total hip arthroplasty, which can greatly improve hip joint function and relieve pain without significant complications. Provided the overall physical condition of a patient and their economic situation make surgery a feasible option and the surgeon is experienced, this treatment is a worthwhile surgical intervention for bilateral hip bony ankylosis. However, the technically demanding nature of the procedure and potential pre- and post-operative problems should not be underestimated. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Kemp, Joanne L; Moore, Kate; Fransen, Marlene; Russell, Trevor G; Crossley, Kay M
2015-01-27
Early-onset hip osteoarthritis is commonly seen in people undergoing hip arthroscopy and is associated with increased pain, reduced ability to participate in physical activity, reduced quality of life and reduced range of motion and muscle strength. Despite this, the efficacy of non-surgical interventions such as exercise therapies remains unknown. The primary aim is to establish the feasibility of a phase III randomised controlled trial investigating a targeted physiotherapy intervention for people with early-onset hip osteoarthritis. The secondary aims are to determine the size of treatment effects of a physiotherapy intervention, targeted to improve hip joint range and hip-related symptoms in early-onset hip osteoarthritis following hip arthroscopy, compared to a health-education control. This protocol describes a randomised, assessor- and participant-blind, controlled clinical trial. We will include 20 participants who are (i) aged between 18 and 50 years; (ii) have undergone hip arthroscopy during the past six to 12 months; (iii) have early-onset hip osteoarthritis (defined as chondrolabral pathology) at the time of hip arthroscopy; and (iv) experience hip-related pain during activities. Primary outcome will be the feasibility of a phase III clinical trial. Secondary outcomes will be (i) perceived global change score; (ii) hip-related symptoms (measured using the Hip disability and Osteoarthritis Outcome Score (HOOS) pain subscale, activity subscale, and sport and recreation subscale); (iii) hip quality of life (measured using the HOOS quality of life subscale and International Hip Outcome tool; (iv) hip muscle strength and (v) hip range of motion. The physiotherapy intervention is semi-standardised, including joint and soft tissue mobilisation and stretching, hip and trunk muscle retraining and functional and activity-specific retraining and education. The control intervention encompasses individualised health education, with the same frequency and duration as the intervention. The trial primary end-point is the conclusion of the 12-week intervention, and follow-up measures will be collected at the 12-week post-baseline assessment. The findings of this study will provide guidance regarding the feasibility of a full-scale phase III randomised controlled trial, prior to its undertaking. The trial protocol was registered with the Australian Clinical Trials Registry (number: 12614000426684 ) on 17 April 2014.
Effect of hip and knee position on nerve conduction in the common fibular nerve.
Broadhurst, Peter Kaas; Robinson, Lawrence R
2017-09-01
The aim of this study was to measure the influence that hip and knee position have on routine fibular motor nerve conduction studies. Healthy subjects under age 40 were recruited (n = 24) to have fibular nerve conduction studies completed in various positions, using hip extension-knee extension as a control. A mean increase in conduction velocity of 2.5 m/s across the knee (P = 0.020) was seen during hip flexion compared with hip extension. A mean decrease in velocity of 1.6 m/s through the leg segment (P = 0.016) was seen during knee flexion compared with knee extension. This study shows that the optimal position of the leg during fibular nerve studies is with the hip in flexion and knee in extension, to more accurately reflect nerve length for velocity calculations. This may have implications for other peripheral nerves with respect to proximal joint position affecting calculated velocity. Muscle Nerve 56: 519-521, 2017. © 2017 Wiley Periodicals, Inc.
Frontal plane kinematics of the hip during running: Are they related to hip anatomy and strength?
Baggaley, Michael; Noehren, Brian; Clasey, Jody L; Shapiro, Robert; Pohl, Michael B
2015-10-01
Excessive hip adduction has been associated with a number of lower extremity overuse running injuries. The excessive motion has been suggested to be the result of reduced strength of the hip abductor musculature. Hip anatomical alignment has been postulated to influence hip abduction (HABD) strength and thus may impact hip adduction during running. The purpose of this study was to investigate the relationship between hip anatomy, HABD strength, and frontal plane kinematics during running. Peak isometric HABD strength, 3D lower extremity kinematics during running, femoral neck-shaft angle (NSA), and pelvis width-femur length (PW-FL) ratio were recorded for 25 female subjects. Pearson correlations (p<0.05) were performed between variables. A fair relationship was observed between femoral NSA and HABD strength (r=-0.47, p=0.02) where an increased NSA was associated with reduced HABD strength. No relationship was observed between HABD strength and hip adduction during running. None of the anatomical measurements, NSA or PW-FL, were associated with hip adduction during running. Deviations in the femoral NSA have a limited ability to influence peak isometric hip abduction strength or frontal plane hip kinematics during running. Hip abduction strength does also not appear to be linked with changes in hip kinematics. These findings in healthy individuals question whether excessive hip adduction typically seen in female runners with overuse injuries is caused by deviations in hip abduction strength or anatomical structure. Copyright © 2015 Elsevier B.V. All rights reserved.
Prevalence of cam hip shape morphology: a systematic review.
Dickenson, E; Wall, P D H; Robinson, B; Fernandez, M; Parsons, H; Buchbinder, R; Griffin, D R
2016-06-01
Cam hip shape morphology is a recognised cause of femoroacetabular impingement (FAI) and is associated with hip osteoarthritis. Our aim was to systematically review the available epidemiological evidence assessing the prevalence of cam hip shape morphology in the general population and any studied subgroups including subjects with and without hip pain. All studies that reported the prevalence of cam morphology, measured by alpha angles, in subjects aged 18 and over, irrespective of study population or presence of hip symptoms were considered for inclusion. We searched AMED, MEDLINE, EMBASE, CINAHL and CENTRAL in October 2015. Two authors independently identified eligible studies and assessed risk of bias. We planned to pool data of studies considered clinically homogenous. Thirty studies met inclusion criteria. None of the included studies were truly population-based: three included non-representative subgroups of the general population, 19 included differing clinical populations, while eight included professional athletes. All studies were judged to be at high risk of bias. Due to substantial clinical heterogeneity meta analysis was not possible. Across all studies, the prevalence estimates of cam morphology ranged from 5 to 75% of participants affected. We were unable to demonstrate a higher prevalence in selected subgroups such as athletes or those with hip pain. There is currently insufficient high quality data to determine the true prevalence of cam morphology in the general population or selected subgroups. Well-designed population-based epidemiological studies that use homogenous case definitions are required to determine the prevalence of cam morphology and its relationship to hip pain. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Outcomes of Hip Arthroscopy in the Older Adult: A Systematic Review of the Literature.
Griffin, Daniel W; Kinnard, Matthew J; Formby, Peter M; McCabe, Michael P; Anderson, Terrence D
2017-07-01
The indications for hip preservation surgery have expanded to include treatment of hip pathology in older adults. While several studies have examined the efficacy of hip arthroscopy in the setting of osteoarthritis, there has been no review of outcomes in older adults. To review the outcomes of hip arthroscopy in older adults and identify factors associated with treatment failures. Systematic review. PubMed, EMBASE, and the Cochrane Library were searched through March 2016 for studies reporting outcomes of primary hip arthroscopy in patients older than 40 years. Inclusion in the review was based on age, patient-reported outcome (PRO) measures, and duration of follow-up. Two authors screened the results and extracted data for use in this review. Standardized mean difference was calculated to estimate effect size for PRO scores within studies. Eight studies with 401 total patients undergoing hip arthroscopy for femoroacetabular impingement (FAI) or labral tears were included in this review. Seven of the 8 studies reported favorable PRO scores and significant postoperative improvement with moderate to large effect size. The included studies demonstrated a trend toward higher effect sizes with an increasing percentage of labral repair compared to isolated labral debridement. The complication rate was comparable to that of previous reports involving younger patients; however, the overall reoperation rate was 20.8%. Conversion to hip arthroplasty ranged from 0% to 30%, with an overall conversion rate of 18.5% at a mean time of 17.5 months following arthroscopy. The most common risk factors for conversion to arthroplasty were low preoperative PRO scores and advanced arthritis. Hip arthroscopy appears to be a safe and efficacious treatment for labral tears and FAI in older patients who do not have significant underlying degenerative changes. However, in this population, there is a significant proportion of patients who eventually require hip arthroplasty. Outcomes may be affected by type of treatment (ie, labral debridement vs repair). Additional high-quality studies are needed to understand how these factors affect outcomes.
De Ridder, Roel; Witvrouw, Erik; Dolphens, Mieke; Roosen, Philip; Van Ginckel, Ans
2017-02-01
Numerous epidemiological studies have emphasized the burden of lateral ankle sprains in youth soccer players. However, no prospective study has identified intrinsic physical and modifiable risk factors for these injuries in this particular population. Although injury prevention programs in soccer incorporate proximal hip and core stability exercises, it is striking that the relationship between impaired proximal hip function and ankle sprains has not yet been prospectively investigated in youth soccer players. This prospective study aimed to examine whether hip muscle strength is a risk factor for sustaining a lateral ankle sprain in youth soccer players. We hypothesized that decreased hip muscle strength would predispose youth soccer players to an increased risk of lateral ankle sprains. Case-control study; Level of evidence, 3. This study included a total of 133 male youth soccer players (age divisions U11-U17) for analysis. At the beginning of the season, anthropometric characteristics were collected and hip muscle strength was assessed using a handheld dynamometer. Injury registration was performed by the team medical staff during 3 consecutive seasons. A principal-component, multivariate Cox regression analysis was performed to identify potential risk factors for sustaining a lateral ankle sprain. Twelve participants (18% of all reported injuries) sustained a lateral ankle sprain (0.36 per 1000 athletic-exposure hours). After adjustment for body size dependencies and other hip muscle forces, an increase in hip muscle extension force was associated with a significant decrease in the hazard of the injury (hazard ratio, 0.3; 95% confidence interval, 0.1-0.9; P = .028). No other study variable could be identified as a risk factor for lateral ankle sprains. Reduced hip extension muscle strength is an independent risk factor for lateral ankle sprains in male youth soccer players. Other hip muscle strength outcomes were not identified as risk factors. Replication in larger samples with more injured cases is warranted to further ascertain the importance of this risk factor.
Rosenlund, Signe; Holsgaard-Larsen, Anders; Overgaard, Søren; Jensen, Carsten
2016-01-01
The Gait Deviation Index summarizes overall gait 'quality', based on kinematic data from a 3-dimensional gait analysis. However, it is unknown which clinical outcomes may affect the Gait Deviation Index in patients with primary hip osteoarthritis. The aim of this study was to investigate associations between Gait Deviation Index as a measure of gait 'quality' and hip muscle strength and between Gait Deviation Index and patient-reported outcomes in patients with primary hip osteoarthritis. Forty-seven patients (34 males), aged 61.1 ± 6.7 years, with BMI 27.3 ± 3.4 (kg/m2) and with severe primary hip osteoarthritis underwent 3-dimensional gait analysis. Mean Gait Deviation Index, pain after walking and maximal isometric hip muscle strength (flexor, extensor, and abductor) were recorded. All patients completed the 'Physical Function Short-form of the Hip disability and Osteoarthritis Outcome Score (HOOS-Physical Function) and the Hip disability and Osteoarthritis Outcome Score subscales for pain (HOOS-Pain) and quality-of-life (HOOS-QOL). Mean Gait Deviation Index was positively associated with hip abduction strength (p<0.01, r = 0.40), hip flexion strength (p = 0.01, r = 0.37), HOOS-Physical Function (p<0.01, r = 0.41) HOOS-QOL (p<0.01, r = 0.41), and negatively associated with HOOS-Pain after walking (p<0.01, r = -0.45). Adjusting the analysis for walking speed did not affect the association. Patients with the strongest hip abductor and hip flexor muscles had the best gait 'quality'. Furthermore, patients with higher physical function, quality of life scores and lower pain levels demonstrated better gait 'quality'. These findings indicate that interventions aimed at improving hip muscle strength and pain management may to a moderate degree improve the overall gait 'quality' in patients with primary hip OA.
Rosenlund, Signe; Holsgaard-Larsen, Anders; Overgaard, Søren; Jensen, Carsten
2016-01-01
Background The Gait Deviation Index summarizes overall gait ‘quality’, based on kinematic data from a 3-dimensional gait analysis. However, it is unknown which clinical outcomes may affect the Gait Deviation Index in patients with primary hip osteoarthritis. The aim of this study was to investigate associations between Gait Deviation Index as a measure of gait ‘quality’ and hip muscle strength and between Gait Deviation Index and patient-reported outcomes in patients with primary hip osteoarthritis. Method Forty-seven patients (34 males), aged 61.1 ± 6.7 years, with BMI 27.3 ± 3.4 (kg/m2) and with severe primary hip osteoarthritis underwent 3-dimensional gait analysis. Mean Gait Deviation Index, pain after walking and maximal isometric hip muscle strength (flexor, extensor, and abductor) were recorded. All patients completed the ‘Physical Function Short-form of the Hip disability and Osteoarthritis Outcome Score (HOOS-Physical Function) and the Hip disability and Osteoarthritis Outcome Score subscales for pain (HOOS-Pain) and quality-of-life (HOOS-QOL). Results Mean Gait Deviation Index was positively associated with hip abduction strength (p<0.01, r = 0.40), hip flexion strength (p = 0.01, r = 0.37), HOOS-Physical Function (p<0.01, r = 0.41) HOOS-QOL (p<0.01, r = 0.41), and negatively associated with HOOS-Pain after walking (p<0.01, r = -0.45). Adjusting the analysis for walking speed did not affect the association. Conclusion Patients with the strongest hip abductor and hip flexor muscles had the best gait ‘quality’. Furthermore, patients with higher physical function, quality of life scores and lower pain levels demonstrated better gait ‘quality’. These findings indicate that interventions aimed at improving hip muscle strength and pain management may to a moderate degree improve the overall gait ‘quality’ in patients with primary hip OA. PMID:27065007
Finsterwald, M; Sidelnikov, E; Orav, E J; Dawson-Hughes, B; Theiler, R; Egli, A; Platz, A; Simmen, H P; Meier, C; Grob, D; Beck, S; Stähelin, H B; Bischoff-Ferrari, H A
2014-01-01
In this study of acute hip fracture patients, we show that hip fracture rates differ by gender between community-dwelling seniors and seniors residing in nursing homes. While women have a significantly higher rate of hip fracture among the community-dwelling seniors, men have a significantly higher rate among nursing home residents. Differences in gender-specific hip fracture risk between community-dwelling and institutionalized seniors have not been well established, and seasonality of hip fracture risk has been controversial. We analyzed detailed data from 1,084 hip fracture patients age 65 years and older admitted to one large hospital center in Zurich, Switzerland. In a sensitivity analysis, we extend to de-personalized data from 1,265 hip fracture patients from the other two large hospital centers in Zurich within the same time frame (total n = 2,349). The denominators were person-times accumulated by the Zurich population in the corresponding age/gender/type of dwelling stratum in each calendar season for the period of the study. In the primary analysis of 1,084 hip fracture patients (mean age 85.1 years; 78% women): Among community-dwelling seniors, the risk of hip fracture was twofold higher among women compared with men (RR = 2.16; 95% CI, 1.74-2.69) independent of age, season, number of comorbidities, and cognitive function; among institutionalized seniors, the risk of hip fracture was 26% lower among women compared with men (RR = 0.77; 95% CI: 0.63-0.95) adjusting for the same confounders. In the sensitivity analysis of 2,349 hip fracture patients (mean age 85.0 years, 76% women), this pattern remained largely unchanged. There is no seasonal swing in hip fracture incidence. We confirm for seniors living in the community that women have a higher risk of hip fracture than men. However, among institutionalized seniors, men are at higher risk for hip fracture.
D’Adamo, Christopher R.; Shardell, Michelle D.; Hicks, Gregory E.; Orwig, Denise L.; Hochberg, Marc C.; Semba, Richard D.; Yu-Yahiro, Janet A.; Ferrucci, Luigi; Magaziner, Jay S.; Miller, Ram R.
2014-01-01
Malnutrition after hip fracture is common and associated with poor outcomes and protracted recovery. Low concentrations of vitamin E have been associated with incident decline in physical function among older adults and may, therefore, be particularly important to functionally compromised patients hip fracture patients. Serum concentrations of α-tocopherol and γ-tocopherol, the 2 major forms of vitamin E, were assessed in 148 female hip fracture patients 65 years or older from the Baltimore Hip Studies cohort 4 around the time of fracture (baseline) and at 2, 6, and 12 month postfracture follow-up visits (recovery). It was hypothesized that mean concentrations of both forms of vitamin E among these hip fracture patients would be lowest at the baseline visit and increase at each study visit during the year after fracture. Linear regression and generalized estimating equations were used to assess changes in vitamin E concentrations after adjustment for covariates and to determine predictors of vitamin E concentrations at baseline and throughout recovery. It was also hypothesized that vitamin E concentrations shortly after hip fracture would be lower than those in nonfracture controls after adjustment for covariates. To evaluate this hypothesis, linear regression was used to perform adjusted comparisons of baseline vitamin E concentrations among Baltimore Hip Studies cohort 4 participants to 1076 older women without history of hip fracture from the Women’s Health and Aging Study I, Invecchiare in Chianti Study, and the National Health and Nutrition Examination Surveys. Mean α-tocopherol was lowest at baseline, and time from fracture to blood draw was positively associated with baseline α-tocopherol (P = .005). Mean γ-tocopherol did not change appreciably throughout the year after fracture, although it fluctuated widely within individuals. Serum concentrations of α-tocopherol and γ-tocopherol were highest among the hip fracture population after adjustment (P < .0001). In general, highly cognitively and physically functioning hip fracture patients demonstrated higher vitamin E concentrations. Thus, the relatively high degree of function among this cohort of hip fracture patients may explain their higher-than-expected vitamin E concentrations. PMID:21481714
D'Adamo, Christopher R; Shardell, Michelle D; Hicks, Gregory E; Orwig, Denise L; Hochberg, Marc C; Semba, Richard D; Yu-Yahiro, Janet A; Ferrucci, Luigi; Magaziner, Jay S; Miller, Ram R
2011-03-01
Malnutrition after hip fracture is common and associated with poor outcomes and protracted recovery. Low concentrations of vitamin E have been associated with incident decline in physical function among older adults and may, therefore, be particularly important to functionally compromised patients hip fracture patients. Serum concentrations of α-tocopherol and γ-tocopherol, the 2 major forms of vitamin E, were assessed in 148 female hip fracture patients 65 years or older from the Baltimore Hip Studies cohort 4 around the time of fracture (baseline) and at 2, 6, and 12 month postfracture follow-up visits (recovery). It was hypothesized that mean concentrations of both forms of vitamin E among these hip fracture patients would be lowest at the baseline visit and increase at each study visit during the year after fracture. Linear regression and generalized estimating equations were used to assess changes in vitamin E concentrations after adjustment for covariates and to determine predictors of vitamin E concentrations at baseline and throughout recovery. It was also hypothesized that vitamin E concentrations shortly after hip fracture would be lower than those in nonfracture controls after adjustment for covariates. To evaluate this hypothesis, linear regression was used to perform adjusted comparisons of baseline vitamin E concentrations among Baltimore Hip Studies cohort 4 participants to 1076 older women without history of hip fracture from the Women's Health and Aging Study I, Invecchiare in Chianti Study, and the National Health and Nutrition Examination Surveys. Mean α-tocopherol was lowest at baseline, and time from fracture to blood draw was positively associated with baseline α-tocopherol (P = .005). Mean γ-tocopherol did not change appreciably throughout the year after fracture, although it fluctuated widely within individuals. Serum concentrations of α-tocopherol and γ-tocopherol were highest among the hip fracture population after adjustment (P < .0001). In general, highly cognitively and physically functioning hip fracture patients demonstrated higher vitamin E concentrations. Thus, the relatively high degree of function among this cohort of hip fracture patients may explain their higher-than-expected vitamin E concentrations. Copyright © 2011 Elsevier Inc. All rights reserved.
Contributions of muscles and passive dynamics to swing initiation over a range of walking speeds.
Fox, Melanie D; Delp, Scott L
2010-05-28
Stiff-knee gait is a common walking problem in cerebral palsy characterized by insufficient knee flexion during swing. To identify factors that may limit knee flexion in swing, it is necessary to understand how unimpaired subjects successfully coordinate muscles and passive dynamics (gravity and velocity-related forces) to accelerate the knee into flexion during double support, a critical phase just prior to swing that establishes the conditions for achieving sufficient knee flexion during swing. It is also necessary to understand how contributions to swing initiation change with walking speed, since patients with stiff-knee gait often walk slowly. We analyzed muscle-driven dynamic simulations of eight unimpaired subjects walking at four speeds to quantify the contributions of muscles, gravity, and velocity-related forces (i.e. Coriolis and centrifugal forces) to preswing knee flexion acceleration during double support at each speed. Analysis of the simulations revealed contributions from muscles and passive dynamics varied systematically with walking speed. Preswing knee flexion acceleration was achieved primarily by hip flexor muscles on the preswing leg with assistance from biceps femoris short head. Hip flexors on the preswing leg were primarily responsible for the increase in preswing knee flexion acceleration during double support with faster walking speed. The hip extensors and abductors on the contralateral leg and velocity-related forces opposed preswing knee flexion acceleration during double support. Copyright 2010 Elsevier Ltd. All rights reserved.
Contributions of muscles and passive dynamics to swing initiation over a range of walking speeds
Fox, Melanie D.; Delp, Scott L.
2010-01-01
Stiff-knee gait is a common walking problem in cerebral palsy characterized by insufficient knee flexion during swing. To identify factors that may limit knee flexion in swing, it is necessary to understand how unimpaired subjects successfully coordinate muscles and passive dynamics (gravity and velocity-related forces) to accelerate the knee into flexion during double support, a critical phase just prior to swing that establishes the conditions for achieving sufficient knee flexion during swing. It is also necessary to understand how contributions to swing initiation change with walking speed, since patients with stiff-knee gait often walk slowly. We analyzed muscle-driven dynamic simulations of eight unimpaired subjects walking at four speeds to quantify the contributions of muscles, gravity, and velocity-related forces (i.e. Coriolis and centrifugal forces) to preswing knee flexion acceleration during double support at each speed. Analysis of the simulations revealed contributions from muscles and passive dynamics varied systematically with walking speed. Preswing knee flexion acceleration was achieved primarily by hip flexor muscles on the preswing leg with assistance from biceps femoris short head. Hip flexors on the preswing leg were primarily responsible for the increase in preswing knee flexion acceleration during double support with faster walking speed. The hip extensors and abductors on the contralateral leg and velocity-related forces opposed preswing knee flexion acceleration during double support. PMID:20236644
Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A
2011-11-01
Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should also be revised to consider the relevance of clinic synovial fluid viscosities and to avoid possible misleading results.
Aguilar, Hector N; Battié, Michele C
2017-01-01
Osteoarthritis is a common hip joint disease, involving loss of articular cartilage. The prevalence and prognosis of hip osteoarthritis have been difficult to determine, with various clinical and radiological methods used to derive epidemiological estimates exhibiting significant heterogeneity. MRI-based methods directly visualise hip joint cartilage, and offer potential to more reliably define presence and severity of osteoarthritis, but have been underused. We performed a systematic review of MRI-based estimates of hip articular cartilage in the general population and in patients with established osteoarthritis, using MEDLINE, EMBASE and SCOPUS current to June 2016, with search terms such as ‘hip’, ‘femoral head’, ‘cartilage’, ‘volume’, ‘thickness’, ‘MRI’, etc. Ultimately, 11 studies were found appropriate for inclusion, but they were heterogeneous in osteoarthritis assessment methodology and composition. Overall, the studies consistently demonstrate the reliability and potential clinical utility of MRI-based estimates. However, no longitudinal data or reference values for hip cartilage thickness or volume have been published, limiting the ability of MRI to define or risk-stratify hip osteoarthritis. MRI-based techniques are available to quantify articular cartilage signal, volume, thickness and defects, which could establish the sequence and rate of articular cartilage changes at the hip that yield symptomatic osteoarthritis. However, prevalence and rates of progression of hip osteoarthritis have not been established in any MRI studies in the general population. Future investigations could fill this important knowledge gap using robust MRI methods in population-based cross-sectional and longitudinal studies. PMID:28405471
Glinka, Michal N; Cheema, Kim P; Robinovitch, Stephen N; Laing, Andrew C
2013-10-01
Safety floors (also known as compliant floors) may reduce the risk of fall-related injuries by attenuating impact force during falls, but are only practical if they do not negatively affect balance and mobility. In this study, we evaluated seven safety surfaces based on their ability to attenuate peak femoral neck force during simulated hip impacts, and their influence on center of pressure (COP) sway during quiet and tandem stance. Overall, we found that some safety floors can attenuate up to 33.7% of the peak femoral impact force without influencing balance. More specifically, during simulated hip impacts, force attenuation for the safety floors ranged from 18.4 (SD 4.3)% to 47.2 (3.1)%, with each floor significantly reducing peak force compared with a rigid surface. For quiet stance, only COP root mean square was affected by flooring (and increased for only two safety floors). During tandem stance, COP root mean square and mean velocity increased in the medial-lateral direction for three of the seven floors. Based on the substantial force attenuation with no concomitant effects on balance for some floors, these results support the development of clinical trials to assess the effectiveness of safety floors at reducing fall-related injuries in high-risk settings.
Kim, Joong-Hwi; Seo, Hye-Jung
2015-05-01
[Purpose] This study evaluated the effects of trunk-hip strengthening exercise on trunk-hip activation and pelvic tilt motion during standing in children with spastic diplegia and compared the improvement of pelvic tilt between the modified trunk-hip strengthening exercise and conventional exercise. [Subjects and Methods] Ten ambulant children with spastic diplegia were randomized to the modified trunk-hip strengthening exercise (n = 5) or conventional exercise (n = 5) group. The intervention consisted of a 6-week modified trunk-hip strengthening exercise 3 times per week. The children were tested for trunk-hip muscles activation and pelvic tilt motion during standing by surface electromyography and an inclinometer before and after the intervention. [Results] The anterior pelvic tilt angle and activation of the extensor spinae, rectus femoris, and semitendinosus during standing decreased significantly in the modified exercise group. The activation of extensor spinae differed significantly between groups. [Conclusion] Compared to the conventional exercise, the modified exercise was more effective for trunk-hip activation improvement and anterior pelvic tilt motion decrease during standing in children with spastic diplegia. We suggest clinicians use an individually tailored modified trunk-hip strengthening exercise for strengthening the weakest muscle groups in children with standing ability problems.
Waelter, S; Scherzinger, E; Hasenbank, R; Nordhoff, E; Lurz, R; Goehler, H; Gauss, C; Sathasivam, K; Bates, G P; Lehrach, H; Wanker, E E
2001-08-15
The huntingtin interacting protein (HIP1) is enriched in membrane-containing cell fractions and has been implicated in vesicle trafficking. It is a multidomain protein containing an N-terminal ENTH domain, a central coiled-coil forming region and a C-terminal actin-binding domain. In the present study we have identified three HIP1 associated proteins, clathrin heavy chain and alpha-adaptin A and C. In vitro binding studies revealed that the central coiled-coil domain is required for the interaction of HIP1 with clathrin, whereas DPF-like motifs located upstream to this domain are important for the binding of HIP1 to the C-terminal 'appendage' domain of alpha-adaptin A and C. Expression of full length HIP1 in mammalian cells resulted in a punctate cytoplasmic immunostaining characteristic of clathrin-coated vesicles. In contrast, when a truncated HIP1 protein containing both the DPF-like motifs and the coiled-coil domain was overexpressed, large perinuclear vesicle-like structures containing HIP1, huntingtin, clathrin and endocytosed transferrin were observed, indicating that HIP1 is an endocytic protein, the structural integrity of which is crucial for maintenance of normal vesicle size in vivo.
MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip.
Nori, Madhavi; Marupaka, Sravan Kumar; Alluri, Swathi; Md, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran
2015-12-01
Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. To study pre and post core decompression MRI changes in avascular necrosis of hip. This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip.
Walsh, Riche; Kinsella, Sharon
2016-04-01
A loss of internal rotation (IR) of the hip is associated with hip pathology. Improving IR may improve hip range of motion (ROM) or prevent hip pathology. The purpose of this study was to compare the immediate effects of caudal mobilisation with movement (MWM) and caudal self-mobilisation with movement (SMWM) on young healthy male subjects with reduced IR of the hip. A randomised controlled trial was performed. Twenty-Two subjects were randomised into a MWM group (n = 6), SMWM group (n = 8) or a control group (n = 8). The primary outcome measures included the functional internal rotation test (FIRT) for the hip and the passive seated internal rotation test (SIRT) for the hip. Outcomes were captured at baseline and immediately after one treatment of MWMs, SMWMs or control. A two-way analysis of variance (ANOVA), group × time interaction was conducted. The ANOVA revealed the only significant improvement was in the MWM group for the FIRT (p = 0.01), over the control group. Subjects with reduced IR of the hip who receive a single session of MWMs exhibited significantly improved functional IR of their hip than the control group. From the data presented, it can be suggested that caudal MWMs of the hip appear to have a positive effect on functional IR of healthy young hips. This may be due to addressing the positional fault theory or the arthrogenic muscular inhibition theory. SMWMs may be effective in augmenting treatments for patients waiting for hip operations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kang, Sun-Young; Jeon, Hye-Seon; Kwon, Ohyun; Cynn, Heon-Seock; Choi, Boram
2013-08-01
The direction of fiber alignment within a muscle is known to influence the effectiveness of muscle contraction. However, most of the commonly used clinical gluteus maximus (GM) exercises do not consider the direction of fiber alignment within the muscle. Therefore, the purpose of this study was to investigate the influence of hip abduction position on the EMG (electromyography) amplitude and onset time of the GM and hamstrings (HAM) during prone hip extension with knee flexion (PHEKF) exercise. Surface EMG signals were recorded from the GM and HAM during PHEKF exercise in three hip abduction positions: 0°, 15°, and 30°. Thirty healthy subjects voluntarily participated in this study. The results show that GM EMG amplitude was greatest in the 30° hip abduction position, followed by 15° and then 0° hip abduction during PHEKF exercise. On the other hand, the HAM EMG amplitude at 0° hip abduction was significantly greater than at 15° and 30° hip abduction. Additionally, GM EMG onset firing was delayed relative to that of the HAM at 0° hip abduction. On the contrary, the GM EMG onset occurred earlier than the HAM in the 15° and 30° hip abduction positions. These findings indicate that performing PHEKF exercise in the 30° hip abduction position may be recommended as an effective way to facilitate the GM muscle activity and advance the firing time of the GM muscle in asymptomatic individuals. This finding provides preliminary evidence that GM EMG amplitude and onset time can be modified by the degree of hip abduction. Copyright © 2012 Elsevier Ltd. All rights reserved.
Todd, Jocelyn N; Maak, Travis G; Ateshian, Gerard A; Maas, Steve A; Weiss, Jeffrey A
2018-03-01
Osteoarthritis of the hip can result from mechanical factors, which can be studied using finite element (FE) analysis. FE studies of the hip often assume there is no significant loss of fluid pressurization in the articular cartilage during simulated activities and approximate the material as incompressible and elastic. This study examined the conditions under which interstitial fluid load support remains sustained during physiological motions, as well as the role of the labrum in maintaining fluid load support and the effect of its presence on the solid phase of the surrounding cartilage. We found that dynamic motions of gait and squatting maintained consistent fluid load support between cycles, while static single-leg stance experienced slight fluid depressurization with significant reduction of solid phase stress and strain. Presence of the labrum did not significantly influence fluid load support within the articular cartilage, but prevented deformation at the cartilage edge, leading to lower stress and strain conditions in the cartilage. A morphologically accurate representation of collagen fibril orientation through the thickness of the articular cartilage was not necessary to predict fluid load support. However, comparison with simplified fibril reinforcement underscored the physiological importance. The results of this study demonstrate that an elastic incompressible material approximation is reasonable for modeling a limited number of cyclic motions of gait and squatting without significant loss of accuracy, but is not appropriate for static motions or numerous repeated motions. Additionally, effects seen from removal of the labrum motivate evaluation of labral reattachment strategies in the context of labral repair. Copyright © 2018 Elsevier Ltd. All rights reserved.
Schappo, Henrique; Gindri, Izabelle M; Cubillos, Patrícia O; Maru, Marcia M; Salmoria, Gean V; Roesler, Carlos R M
2018-01-01
The use of scanning electron microscopy (SEM) and energy-dispersive spectrometry (EDS) was investigated to understand the wear mechanisms from a metal-on-polyethylene bearing couple. Morphological features of femoral head acetabular liner, and isolated particles resulting from hip wear testing were evaluated. EDS was proposed to investigate the polymeric nature of the particles isolated from the wear testing. In this work, 28-mm conventional ultra-high-molecular-weight polyethylene acetabular liners paired with metallic heads were tested in a hip wear simulator over 2 million cycles. SEM-EDS was employed to investigate wear mechanisms on hip implant components and associated wear debris. SEM showed worn surfaces for both hip components, and a significant volume of ultra-high-molecular-weight polyethylene wear particles resulting from hip wear testing. Particles were classified into 3 groups, which were then correlated to wear mechanisms. Group I had particles with smooth surfaces, group II consisted of particles with rough surfaces, and group III comprised aggregate-like particles. Group I EDS revealed that particles from groups I and II had a high C/O ratio raising a concern about the particle source. On the other hand, particles from group III had a low C/O ratio, supporting the hypothesis that they resulted from the wear of acetabular liner. Most of particles identified in group III were in the biologically active size range (0.3 to 20 μm). The use of optical and electron microscopy enabled the morphological characterization of worn surfaces and wear debris, while EDS was essential to elucidate the chemical composition of isolated debris. Copyright © 2017 Elsevier Inc. All rights reserved.
Jiang, Yawen; Ni, Weiyi
2016-11-01
This work was undertaken to provide an estimation of expected lifetime numbers, risks, and burden of fractures for 50-year-old Chinese women. A discrete event simulation model was developed to simulate the lifetime fractures of 50-year-old Chinese women at average risk of osteoporotic fracture. Main events in the model included hip fracture, clinical vertebral fracture, wrist fracture, humerus fracture, and other fracture. Fracture risks were calculated using the FRAX ® tool. Simulations of 50-year-old Chinese women without fracture risks were also carried out as a comparison to determine the burden of fractures. A 50-year-old Chinese woman at average risk of fracture is expected to experience 0.135 (95 % CI: 0.134-0.137) hip fractures, 0.120 (95 % CI: 0.119-0.122) clinical vertebral fractures, 0.095 (95 % CI: 0.094-0.096) wrist fractures, 0.079 (95 % CI: 0.078-0.080) humerus fractures, and 0.407 (95 % CI: 0.404-0.410) other fractures over the remainder of her life. The residual lifetime risk of any fracture, hip fracture, clinical vertebral fracture, wrist fracture, humerus fracture, and other fracture for a 50-year-old Chinese woman is 37.36, 11.77, 10.47, 8.61, 7.30, and 27.80 %, respectively. The fracture-attributable excess quality-adjusted life year (QALY) loss and lifetime costs are estimated at 0.11 QALYs (95 % CI: 0.00-0.22 QALYs) and US $714.61 (95 % CI: US $709.20-720.02), totaling a net monetary benefit loss of US $1,104.43 (95 % CI: US $904.09-1,304.78). Chinese women 50 years of age are at high risk of osteoporotic fracture, and the expected economic and quality-of-life burden attributable to osteoporotic fractures among Chinese women is substantial.
Hip biomechanics during stair ascent and descent in people with and without hip osteoarthritis.
Hall, Michelle; Wrigley, Tim V; Kean, Crystal O; Metcalf, Ben R; Bennell, Kim L
2017-07-01
Hip osteoarthritis (OA) is often associated with pain and impaired function. Understanding biomechanical alterations in patients with hip OA during challenging activities such as stair use is important to inform treatments. The aim of this study was to determine whether kinematics and kinetics during stair ambulation differed between people with hip OA and healthy controls. Fifteen participants with symptomatic and radiographic hip OA and 15 asymptomatic healthy controls underwent 3-D motion analysis during stair ascent and descent. Trunk, pelvis, and hip kinematics as well as hip kinetics were evaluated. Analyses were performed unadjusted and adjusted for speed and leg length. In both the unadjusted and adjusted analyses, participants with hip OA ascended stairs with less hip range of motion in all three planes and a lower peak external rotation moment compared to controls. In the unadjusted analysis, hip OA participants descended stairs with greater ipsilateral trunk lean, less sagittal plane range of motion, lower peak extension moment, lower peak external rotation moment, and greater hip adduction moment impulse compared to controls. In the adjusted results, peak internal rotation moment and hip adduction moment impulse were greater in hip OA participants compared to controls. Findings show that individuals with hip OA display limited range of hip joint movement, particularly during stair ascent, and overall indicate the use of strategies (e.g., trunk lean; lower peak external rotation moment; higher adduction moment impulse) that implicate altered hip abductor function. Future research is required to further understand the implications of these findings on hip OA. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1505-1514, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Hip morphology in elite golfers: asymmetry between lead and trail hips.
Dickenson, Edward; O'Connor, Philip; Robinson, Philip; Campbell, Robert; Ahmed, Imran; Fernandez, Miguel; Hawkes, Roger; Charles, Hutchinson; Griffin, Damian
2016-09-01
During a golf swing, the lead hip (left hip in a right-handed player) rotates rapidly from external to internal rotation, while the opposite occurs in the trail hip. This study assessed the morphology and pathology of golfers' hips comparing lead and trail hips. A cohort of elite golfers were invited to undergo MRI of their hips. Hip morphology was evaluated by measuring acetabular depth (pincer shape=negative measure), femoral neck antetorsion (retrotorsion=negative measure) and α angles (cam morphology defined as α angle >55° anteriorly) around the axis of the femoral neck. Consultant musculoskeletal radiologists determined the presence of intra-articular pathology. 55 players (mean age 28 years, 52 left hip lead) underwent MRI. No player had pincer morphology, 2 (3.6%) had femoral retrotorsion and 9 (16%) had cam morphology. 7 trail hips and 2 lead hips had cam morphology (p=0.026). Lead hip femoral neck antetorsion was 16.7° compared with 13.0° in the trail hip (p<0.001). The α angles around the femoral neck were significantly lower in the lead compared with trail hips (p<0.001), with the greatest difference noted in the anterosuperior portion of the head neck junction; 53° vs 58° (p<0.001) and 43° vs 47° (p<0.001). 37% of trail and 16% of lead hips (p=0.038) had labral tears. Golfers' lead and trail hips have different morphology. This is the first time side-to-side asymmetry of cam prevalence has been reported. The trail hip exhibited a higher prevalence of labral tears. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Outcomes of Revision Hip Arthroscopy: 2-Year Clinical Follow-up.
Gupta, Asheesh; Redmond, John M; Stake, Christine E; Dunne, Kevin F; Hammarstedt, Jon E; Domb, Benjamin G
2016-05-01
To evaluate clinical outcomes, pain, and patient satisfaction following revision hip arthroscopy with a minimum 2-year follow-up. From April 2008 to October 2011, data were prospectively collected on all patients undergoing revision hip arthroscopy. All patients were assessed pre- and postoperatively with 4 patient-reported outcome (PRO) measures: the modified Harris hip score (mHHS), nonarthritic hip score (NAHS), hip outcome score-activities of daily living (HOS-ADL), and hip outcome score-sport-specific subscales (HOS-SSS). Pain was estimated on the visual analog scale (VAS). Patient satisfaction was measured on a scale from 0 to 10. The number of patients who underwent subsequent revision arthroscopy or total hip arthroplasty during the study period is also reported. Eighty-seven patients underwent revision hip arthroscopy during the study period. Seventy (80.5%) patients were included in our study. Average follow-up time was 28 months (range, 20 to 47.4 months). In terms of residual femoroacetabular impingement morphology, 45.7% of patients had preoperative alpha angles ≥ 55°, and 7.14% of patients had a lateral center-edge angle ≥ 40°. The score improvement from preoperative to 2-year follow-up was 57.84 to 73.65 for mHHS, 62.79 to 83.04 for HOS-ADL, 37.33 to 54.93 for HOS-SSS, and 55.65 to 70.79 for NAHS. VAS decreased from 6.72 to 4.08. All scores demonstrated statistically significant improvement (P < .001). Overall patient satisfaction was 7.67. Our success rate was 74.58%. Ten (14.29%) patients underwent total hip arthroplasty during the study period. Our hip survivorship was 85.7%. Five (7.14%) patients underwent secondary revision hip arthroscopy during the study period. We found an overall minor complication rate of 10%. Revision hip arthroscopy for all procedures performed on aggregate has improved clinical outcomes for all PROs, high survivorship, and high patient satisfaction scores at short-term follow-up. Patients should be counseled regarding the potential progression of degenerative change leading to arthroplasty and the potential for revision surgery. Level IV retrospective case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Hip instability: a review of hip dysplasia and other contributing factors
Kraeutler, Matthew J.; Garabekyan, Tigran; Pascual-Garrido, Cecilia; Mei-Dan, Omer
2016-01-01
Summary Background Hip instability has classically been associated with developmental dysplasia of the hip (DDH) in newborns and children. However, numerous factors may contribute to hip instability in children, adolescents, and adults. Purpose This review aims to concisely present the literature on hip instability in patients of all ages in order to guide health care professionals in the appropriate diagnosis and treatment of the various disorders which may contribute to an unstable hip. Methods We reviewed the literature on the diagnosis and surgical management of hip dysplasia and other causes of hip instability. Conclusions Multiple intra- and extra-articular variables may contribute to hip instability, including acetabular bony coverage, femoral torsion, femoroacetabular impingement, and soft tissue laxity. Physical examination and advanced imaging studies are essential to accurately diagnose the pathology contributing to a patient’s unstable hip. Conservative management, including activity modification and physical therapy, may be used as a first-line treatment in patients with intra-articular hip pathology. Patients who continue to experience symptoms of pain or instability should proceed with arthroscopic or open surgical treatment aimed at correcting the underlying pathology. Level of evidence V. PMID:28066739
Mastenbrook, Matthew J; Commean, Paul K; Hillen, Travis J; Salsich, Gretchen B; Meyer, Gretchen A; Mueller, Michael J; Clohisy, John C; Harris-Hayes, Marcie
2017-12-01
Study Design Secondary analysis, cross-sectional study. Background Chronic hip joint pain (CHJP) can lead to limitations in activity participation, but the musculoskeletal factors associated with the condition are relatively unknown. Understanding the factors associated with CHJP may help develop rehabilitation strategies to improve quality of life of individuals with long-term hip pain. Objectives To compare measures of hip abductor muscle volume and hip abductor muscle strength between women with CHJP and asymptomatic controls. Methods Thirty women, 15 with CHJP and 15 matched asymptomatic controls (age range, 18-40 years), participated in this study. Magnetic resonance imaging was used to determine the volume of the primary hip abductor muscles, consisting of the gluteus medius, gluteus minimus, a small portion of the gluteus maximus, and the tensor fascia latae, within a defined region of interest. Break tests were performed using a handheld dynamometer to assess hip abductor strength. During the strength test, the participant was positioned in sidelying with the involved hip in 15° of abduction. Independent-samples t tests were used to compare muscle volume and strength values between those with CHJP and asymptomatic controls. Results Compared to asymptomatic controls, women with CHJP demonstrated significantly increased gluteal muscle volume (228 ± 40 cm 3 versus 199 ± 29 cm 3 , P = .032), but decreased hip abductor strength (74.6 ± 16.8 Nm versus 93.6 ± 20.2 Nm, P = .009). There were no significant differences in tensor fascia lata muscle volume between the 2 groups (P = .640). Conclusion Women with CHJP appear to have larger gluteal muscle volume, but decreased hip abductor strength, compared to asymptomatic controls. J Orthop Sports Phys Ther 2017;47(12):923-930. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7380.
Hicks, Gregory E; Sions, J Megan; Velasco, Teonette O
2017-10-27
To determine (1) whether there are differences in the prevalence of clinical hip symptoms between older adults with and without chronic low back pain (CLBP); and (2) whether coexisting hip symptoms are associated with worse physical performance and poorer health-related quality of life (HRQOL). Case-control study. Individuals participated in a standardized evaluation in a clinical laboratory. Clinical hip symptoms, which are proposed predictors of radiographic hip osteoarthritis according to American College of Rheumatology guidelines, were evaluated in a volunteer sample of community-dwelling older adults with CLBP (n=54; aged 60-85y) and in age- and sex-matched healthy controls (n=54). Not applicable. Physical performance was measured by the repeated chair rise test and stair-climbing test. HRQOL was measured by the Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36). Hip joint pain, morning stiffness, and pain with hip internal rotation were more common among older adults with CLBP (P<.05). Participants with CLBP and coexisting hip symptoms had worse physical performance than individuals without CLBP or hip symptoms (P<.0001). Additionally, the presence of coexisting hip symptoms was associated with worse HRQOL, particularly in the domains of social functioning, mental health, and role limitations attributable to emotional problems as measured by the SF-36 (P<.01). Given our limited understanding of CLBP among older adults, there is a definitive need to systematically explore coexisting pain conditions that may contribute to worse outcomes. Based on these data, future longitudinal studies should explore whether coexisting hip symptoms are associated with a worse prognosis in older adults with CLBP. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Fragility non-hip fracture patients are at risk.
Gosch, M; Druml, T; Nicholas, J A; Hoffmann-Weltin, Y; Roth, T; Zegg, M; Blauth, M; Kammerlander, C
2015-01-01
Fragility fractures are a growing worldwide health care problem. Hip fractures have been clearly associated with poor outcomes. Fragility fractures of other bones are common reasons for hospital admission and short-term disability, but specific long-term outcome studies of non-hip fragility fractures are rare. The aim of our trial was to evaluate the 1-year outcomes of non-hip fragility fracture patients. This study is a retrospective cohort review of 307 consecutive older inpatient non-hip fracture patients. Patient data for analysis included fracture location, comorbidity prevalence, pre-fracture functional status, osteoporosis treatments and sociodemographic characteristics. The main outcomes evaluated were 1-year mortality and post-fracture functional status. As compared to the expected mortality, the observed 1-year mortality was increased in the study group (17.6 vs. 12.2 %, P = 0.005). After logistic regression, three variables remained as independent risk factors for 1-year mortality among non-hip fracture patients: malnutrition (OR 3.3, CI 1.5-7.1), Charlson comorbidity index (CCI) (OR 1.3, CI 1.1-1.5) and the Parker Mobility Score (PMS) (OR 0.85, CI 0.74-0.98). CCI and PMS were independent risk factors for a high grade of dependency after 1 year. Management of osteoporosis did not significantly improve after hospitalization due to a non-hip fragility fracture. The outcomes of older non-hip fracture patients are comparable to the poor outcomes of older hip fracture patients, and appear to be primarily related to comorbidities, pre-fracture function and nutritional status. The low rate of patients on osteoporosis medications likely reflects the insufficient recognition of the importance of osteoporosis assessment and treatment in non-hip fracture patients. Increased clinical and academic attention to non-hip fracture patients is needed.
Lai, Shih-Wei; Liao, Kuan-Fu; Liao, Chien-Chang; Muo, Chih-Hsin; Liu, Chiu-Shong; Sung, Fung-Chang
2010-09-01
Few studies have addressed the association between polypharmacy and hip fracture using population data. We conducted a population-based case-control study to investigate whether polypharmacy increases the risk for hip fracture in the elderly. We used insurance claims data from the Taiwan Bureau of National Health Insurance, a universal insurance program with a coverage rate of more than 98% of the population in Taiwan. We identified 2328 elderly patients with newly diagnosed hip fracture during the period 2005-2007. We randomly selected 9312 individuals without hip fracture to serve as the control group. Patient characteristics, drugs prescribed by physicians, and all types of hip fracture were ascertained. The odds ratio (OR) of hip fracture in association with the number of medications used per day in previous years was assessed.We found that patients were older than controls, predominantly female, and more likely to use 5 or more drugs (22.2% vs. 9.3%, p < 0.0001). The OR of hip fracture increased with the number of medications used per day and with age. Multivariate logistic regression analysis revealed that the overall OR for patients using 10 or more drugs was 8.42 (95% confidence interval [CI], 4.73-15.0) compared with patients who used 0-1 drug per day. However, age-specific analysis revealed that the risk for hip fracture was 23 times greater for patients aged > or = 85 years who used 10 or more drugs than for those aged 65-74 years who used 0-1 drug after controlling for covariates (OR, 23.0; 95% CI, 3.77-140).We conclude that the risk of hip fracture in older people increases with the number of medications used, especially in women. Age interacts with the daily medications for the risk of hip fracture.
Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi
2017-02-01
The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.
Can we prevent hip dislocation in children with cerebral palsy? Effects of postural management.
Picciolini, Odoardo; LE Métayer, Michel; Consonni, Dario; Cozzaglio, Massimo; Porro, Matteo; Gasparroni, Verusca; Panou, Artemisia; Mosca, Fabio; Portinaro, Nicola M
2016-10-01
Hip dislocation is common in children with cerebral palsy (CP). At birth they do not have musculoskeletal deformities but they develop over time due to the combined effects of the movement disorder and impaired gross motor function. Early detection and treatment of a hip at risk is needed to modify the natural of hip development in CP. The aim of this study was to determine the effect of postural management treatment on hip displacement's progression in children CP. Prospective comparative non-randomized study. Rehabilitative outpatient unit. Fifty-one children with CP were studied; the treated group (N.=30) was compared to a control group (N.=21). The treated group followed a two year's long combined treatment program consisting a neurodevelopment treatment (NDT) two times a week and a 5 hours daily siège moulé postural program. The control group underwent only NDT twice a week for two years. Hip radiographs were measured with the migration percentage (MP) method at baseline, at 1 and 2 years of follow-up. A significant difference has been observed in the MP (%) trend (P<0.001) between treatment and control groups. At 2 years, there was a marked worsening (MP from 23.0 to 37.7) in the control group, compared to the stability (from 28.8 to 26.8) in the treatment group. This study supports the evidence that conservative postural management of hip deformity is useful to prevent the natural progression of hip dislocation. Hip radiographic follow up program together with NDT and postural management program is useful to modify the natural progression of hip dislocation in children with CP.
Risk of hip fracture in Addison's disease: a population-based cohort study.
Björnsdottir, S; Sääf, M; Bensing, S; Kämpe, O; Michaëlsson, K; Ludvigsson, J F
2011-08-01
The results of studies of bone mineral density in Addison's disease (AD) are inconsistent. There are no published data on hip fracture risk in patients with AD. In this study, we compare hip fracture risk in adults with and without AD. A population-based cohort study. Through the Swedish National Patient Register and the Total Population Register, we identified 3219 patients without prior hip fracture who were diagnosed with AD at the age of ≥30 years during the period 1964-2006 and 31 557 age- and sex-matched controls. Time to hip fracture was measured. We observed 221 hip fractures (6.9%) in patients with AD and 846 (2.7%) in the controls. Patients with AD had a higher risk of hip fracture [hazard ratio (HR) = 1.8; 95% confidence interval (CI), 1.6-2.1; P < 0.001]. This risk increase was independent of sex and age at or calendar period of diagnosis. Risk estimates did not change with adjustment for type 1 diabetes, autoimmune thyroid disease, rheumatoid arthritis or coeliac disease. Women diagnosed with AD ≤50 years old had the highest risk of hip fracture (HR = 2.7; 95 % CI, 1.6-4.5). We found a positive association between hip fracture and undiagnosed AD [odds ratio (OR) = 2.4; 95 % CI, 2.1-3.0] with the highest risk estimates in the last year before AD diagnosis (OR = 2.8; 95 % CI, 1.8-4.2). Both clinically undiagnosed and diagnosed AD was associated with hip fractures, with the highest relative risk seen in women diagnosed with AD ≤50 years of age. © 2011 The Association for the Publication of the Journal of Internal Medicine.
Charbonnier, Caecilia; Kolo, Frank C; Duthon, Victoria B; Magnenat-Thalmann, Nadia; Becker, Christoph D; Hoffmeyer, Pierre; Menetrey, Jacques
2011-03-01
Early hip osteoarthritis in dancers could be explained by femoroacetabular impingements. However, there is a lack of validated noninvasive methods and dynamic studies to ascertain impingement during motion. Moreover, it is unknown whether the femoral head and acetabulum are congruent in typical dancing positions. The practice of some dancing movements could cause a loss of hip joint congruence and recurrent impingements, which could lead to early osteoarthritis. Descriptive laboratory study. Eleven pairs of female dancer's hips were motion captured with an optical tracking system while performing 6 different dancing movements. The resulting computed motions were applied to patient-specific hip joint 3-dimensional models based on magnetic resonance images. While visualizing the dancer's hip in motion, the authors detected impingements using computer-assisted techniques. The range of motion and congruence of the hip joint were also quantified in those 6 recorded dancing movements. The frequency of impingement and subluxation varied with the type of movement. Four dancing movements (développé à la seconde, grand écart facial, grand écart latéral, and grand plié) seem to induce significant stress in the hip joint, according to the observed high frequency of impingement and amount of subluxation. The femoroacetabular translations were high (range, 0.93 to 6.35 mm). For almost all movements, the computed zones of impingement were mainly located in the superior or posterosuperior quadrant of the acetabulum, which was relevant with respect to radiologically diagnosed damaged zones in the labrum. All dancers' hips were morphologically normal. Impingements and subluxations are frequently observed in typical ballet movements, causing cartilage hypercompression. These movements should be limited in frequency. The present study indicates that some dancing movements could damage the hip joint, which could lead to early osteoarthritis.
Potvin, Brigitte M; Shourijeh, Mohammad S; Smale, Kenneth B; Benoit, Daniel L
2017-09-06
Musculoskeletal modeling and simulations have vast potential in clinical and research fields, but face various challenges in representing the complexities of the human body. Soft tissue artifact from skin-mounted markers may lead to non-physiological representation of joint motions being used as inputs to models in simulations. To address this, we have developed adaptive joint constraints on five of the six degree of freedom of the knee joint based on in vivo tibiofemoral joint motions recorded during walking, hopping and cutting motions from subjects instrumented with intra-cortical pins inserted into their tibia and femur. The constraint boundaries vary as a function of knee flexion angle and were tested on four whole-body models including four to six knee degrees of freedom. A musculoskeletal model developed in OpenSim simulation software was constrained to these in vivo boundaries during level gait and inverse kinematics and dynamics were then resolved. Statistical parametric mapping indicated significant differences (p<0.05) in kinematics between bone pin constrained and unconstrained model conditions, notably in knee translations, while hip and ankle flexion/extension angles were also affected, indicating the error at the knee propagates to surrounding joints. These changes to hip, knee, and ankle kinematics led to measurable changes in hip and knee transverse plane moments, and knee frontal plane moments and forces. Since knee flexion angle can be validly represented using skin mounted markers, our tool uses this reliable measure to guide the five other degrees of freedom at the knee and provide a more valid representation of the kinematics for these degrees of freedom. Copyright © 2017 Elsevier Ltd. All rights reserved.
Afschrift, Maarten; De Groote, Friedl; Verschueren, Sabine; Jonkers, Ilse
2018-01-01
The response to stance perturbations changes with age. The shift from an ankle to a hip strategy with increasing perturbation magnitude occurs at lower accelerations in older than in young adults. This strategy shift has been related to age-related changes in muscle and sensory function. However, the effect of isolated changes in muscle or sensory function on the responses following stance perturbations cannot be determined experimentally since changes in muscle and sensory function occur simultaneously. Therefore, we used predictive simulations to estimate the effect of isolated changes in (rates of change in) maximal joint torques, functional base of support, and sensory noise on the response to backward platform translations. To evaluate whether these modeled changes in muscle and sensory function could explain the observed changes in strategy; simulated postural responses with a torque-driven double inverted pendulum model controlled using optimal state feedback were compared to measured postural responses in ten healthy young and ten healthy older adults. The experimentally observed peak hip angle during the response was significantly larger (5°) and the functional base of support was smaller (0.04m) in the older than in the young adults but peak joint torques and rates of joint torque were similar during the recovery. The addition of noise to the sensed states in the predictive simulations could explain the observed increase in peak hip angle in the elderly, whereas changes in muscle function could not. Hence, our results suggest that strength training alone might be insufficient to improve postural control in elderly. Copyright © 2017 Elsevier B.V. All rights reserved.
Ma, Richard; Zhou, Hanbing; Thompson, Matthew; Dawson, Courtney; Nguyen, Joseph; Coleman, Struan
2015-01-01
Normal hip range of motion (ROM) is essential in running and transfer of energy from lower to upper extremities during overhead throwing. Dysfunctional hip ROM may alter lower extremity kinematics and predispose athletes to hip and groin injuries. The purpose of this study is characterize hip internal/external ROM (Arc) and its effect on the risk of hip, hamstring, and groin injuries in professional baseball players. Bilateral hip internal and external ROM was measured on all baseball players (N=201) in one professional organization (major and minor league) during spring training. Players were organized according to their respective positions. All injuries were documented prospectively for an entire MLB season (2010 to 2011). Data was analyzed according to position and injuries during the season. Total number of players (N=201) with an average age of 24±3.6 (range=17-37). Both pitchers (N=93) and catchers (N=22) had significantly decreased mean hip internal rotation and overall hip arc of motion compared to the positional players (N=86). Players with hip, groin, and hamstring injury also had decreased hip rotation arc when compared to the normal group. Overall, there is a correlation between decreased hip internal rotation and total arc of motion with hip, hamstring, and groin injuries. PMID:26793294
Santos, Thiago R. T.; Oliveira, Bárbara A.; Ocarino, Juliana M.; Holt, Kenneth G.; Fonseca, Sérgio T.
2015-01-01
Introduction: Patellofemoral pain syndrome (PFPS) is characterized by anterior knee pain, which may limit the performance of functional activities. The influence of hip joint motion on the development of this syndrome has already been documented in the literature. In this regard, studies have investigated the effectiveness of hip muscle strengthening in patients with PFPS. Objectives: The aims of this systematic review were (1) to summarize the literature related to the effects of hip muscle strengthening on pain intensity, muscle strength, and function in individuals with PFPS and (2) to evaluate the methodological quality of the selected studies. Method: A search for randomized controlled clinical trials was conducted using the following databases: Google Scholar, MEDLINE, PEDro, LILACS, and SciELO. The selected studies had to distinguish the effects of hip muscle strengthening in a group of patients with PFPS, as compared to non-intervention or other kinds of intervention, and had to investigate the following outcomes: pain, muscle strength, and function. The methodological quality of the selected studies was analyzed by means of the PEDro scale. Results: Seven studies were selected. These studies demonstrated that hip muscle strengthening was effective in reducing pain. However, the studies disagreed regarding the treatments' ability to improve muscle strength. Improvement in functional capabilities after hip muscle strengthening was found in five studies. Conclusion: Hip muscle strengthening is effective in reducing the intensity of pain and improving functional capabilities in patients with PFPS, despite the lack of evidence for its ability to increase muscle strength. PMID:26039034
Habets, B; Smits, H W; Backx, F J G; van Cingel, R E H; Huisstede, B M A
2017-05-01
Investigating differences in hip muscle strength between athletes with Achilles tendinopathy (AT) and asymptomatic controls. Cross-sectional case-control study. Sports medical center. Twelve recreational male athletes with mid-portion AT and twelve matched asymptomatic controls. Isometric strength of the hip abductors, external rotators, and extensors was measured using a handheld dynamometer. Functional hip muscle performance was evaluated with the single-leg squat. The Victorian Institute of Sport Assessment-Achilles (VISA-A) questionnaire was completed to determine clinical severity of symptoms. Compared to controls, participants with AT demonstrated 28.9% less isometric hip abduction strength (p = 0.012), 34.2% less hip external rotation strength (p = 0.010), and 28.3% less hip extension strength (p = 0.034) in the injured limb. Similar differences were found for the non-injured limb (26.7-41.8%; p < 0.03). No significant differences were found in functional hip muscle performance between the injured and non-injured limb or between the groups, and no significant correlation was found between hip muscle strength and VISA-A scores. Recreational male athletes with chronic mid-portion AT demonstrated bilateral weakness of hip abductors, external rotators, and extensors compared to their asymptomatic counterparts. These findings suggest that hip muscle strength may be important in the assessment and rehabilitation of those with AT. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gender differences exist in the hip joint moments of healthy older walkers.
Boyer, Katherine A; Beaupre, Gary S; Andriacchi, Thomas P
2008-12-05
Gender differences in the incidence of symptomatic hip osteoarthritis (OA), changes in hip cartilage volume and hip joint space and rates hip arthroplasty of older people are reported in the literature. As the rate of progression of OA is in part mechanically modulated it is possible that this gender bias may be related to inherent differences (if they exist) in walking mechanics between older males and females. The purpose of this study was to examine potential mechanisms for gender differences in hip joint mechanics during walking by testing the hypotheses that females would exhibit higher hip flexion, adduction and internal rotation moments but not significantly greater normalized ground reaction forces (GRFs). Forty-two healthy subjects (21 male, 21 female), ages 50-79yr were recruited for gait analysis. In support of the hypotheses, greater external hip adduction and internal rotation along with hip extension moments were found for females compared to males after normalizing for body size for all self-selected walking speeds. Differences in walking style (kinematics) were the main determinants in the joint kinetic differences as no differences in the normalized GRFs were found. As external joint moments are surrogate measures of the joint contact forces, the results of this study suggest the hip joint stress for the female population is higher compared to male population. This is in favor of a hypothesis that the increased joint contact stress in a female population could contribute to a greater joint degeneration at the hip in females as compared with males.
ERIC Educational Resources Information Center
Kuh, George; O'Donnell, Ken; Schneider, Carol Geary
2017-01-01
2017 is the anniversary of the introduction of what are now commonly known as high-impact practices (HIPs). Many of the specific activities pursued under the HIPs acronym have been around in some form for decades, such as study abroad, internships, and student-faculty research. It was about ten years ago that, after conferring HIPs at Ten with…
Svehlík, Martin; Kraus, Tanja; Steinwender, Gerhard; Zwick, Ernst B; Linhart, Wolfgang E
2012-06-01
Legg-Calvé-Perthes disease (LCP) severely limits the range of hip motion and hinders a normal gait. Loading of the hip joint is a major consideration in LCP treatment. The aim of this study was to evaluate gait patterns in LCP and identify gait modifications to decrease the load on the affected hip. Forty children with unilateral LCP were divided into three groups based on the time base integral of the hip abductor moments during single stance on the affected side acquired during instrumented 3D gait analysis. X-rays of the affected hip were classified according to Herring and Catterall. Children in the "unloading" group spontaneously adopted a Duchenne-like gait with pelvis elevation, hip abduction and external rotation during single support phase. The "normal-loading" group showed pelvis elevation with a neutral hip position in the frontal plane. In the "overloading" group the pelvis dropped to the swinging limb at the beginning of stance accompanied by prolonged hip adduction. The time base integral of the hip abductor moments during single stance correlated positively with the X-ray classifications of Herring and Catterall, hip abduction angle and age. Older children preferred to walk in hip adduction during single stance, had more impaired hips and tended to overload them. The hip overloading pattern should be avoided in children with LCP. Gait training to unload the hip might become an integral component of conservative treatment in children with LCP.
The History of Biomechanics in Total Hip Arthroplasty.
Houcke, Jan Van; Khanduja, Vikas; Pattyn, Christophe; Audenaert, Emmanuel
2017-01-01
Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro , in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA). The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.
Beaulieu, Mélanie L; Wojtys, Edward M; Ashton-Miller, James A
2015-09-01
A reduced range of hip internal rotation is associated with increased peak anterior cruciate ligament (ACL) strain and risk for injury. It is unknown, however, whether limiting the available range of internal femoral rotation increases the susceptibility of the ACL to fatigue failure. Risk of ACL failure is significantly greater in female knee specimens with a limited range of internal femoral rotation, smaller femoral-ACL attachment angle, and smaller tibial eminence volume during repeated in vitro simulated single-leg pivot landings. Controlled laboratory study. A custom-built testing apparatus was used to simulate repeated single-leg pivot landings with a 4×-body weight impulsive load that induces knee compression, knee flexion, and internal tibial torque in 32 paired human knee specimens from 8 male and 8 female donors. These test loads were applied to each pair of specimens, in one knee with limited internal femoral rotation and in the contralateral knee with femoral rotation resisted by 2 springs to simulate the active hip rotator muscles' resistance to stretch. The landings were repeated until ACL failure occurred or until a minimum of 100 trials were executed. The angle at which the ACL originates from the femur and the tibial eminence volume were measured on magnetic resonance images. The final Cox regression model (P = .024) revealed that range of internal femoral rotation and sex of donor were significant factors in determining risk of ACL fatigue failure. The specimens with limited range of internal femoral rotation had a failure risk 17.1 times higher than did the specimens with free rotation (P = .016). The female knee specimens had a risk of ACL failure 26.9 times higher than the male specimens (P = .055). Limiting the range of internal femoral rotation during repetitive pivot landings increases the risk of an ACL fatigue failure in comparison with free rotation in a cadaveric model. Screening for restricted internal rotation at the hip in ACL injury prevention programs as well as in individuals with ACL injuries and/or reconstructions is warranted. © 2015 The Author(s).
Harris-Hayes, Marcie; Sahrmann, Shirley A; Van Dillen, Linda R
2009-02-01
Hip function has been proposed to be related to low back pain (LBP) because of the anatomical proximity of the hip and lumbopelvic region. To date, findings have been inconclusive, possibly because the samples studied were heterogeneous. Sub-grouping samples based on characteristics such as activity demand, LBP classification, and sex might clarify research findings. To describe and summarize studies that examine 3 factors proposed to be important to the study of the hip-LBP relationship. Review of cross-sectional studies. Academic health-care center and research laboratory. 3 groups: athletes with a history of LBP who regularly participate in rotation-related sports, athletes without a history of LBP who are active but do not regularly participate in rotation-related sports, and athletes without a history of LBP who participate in rotation-related sports. Hip range of motion and hip-lumbopelvic region coordination. Hip range of motion was measured with an inclinometer. Coordination was examined based on kinematics obtained with a 3-dimensional motion-capture system. Differences among groups were found based on activity demand, LBP classification, and sex. When assessing athletes with and without LBP, characteristics such as activity demand, LBP classification, and sex should be considered.
Dairy product consumption and risk of hip fracture: a systematic review and meta-analysis.
Bian, Shanshan; Hu, Jingmin; Zhang, Kai; Wang, Yunguo; Yu, Miaohui; Ma, Jie
2018-01-22
Dairy product consumption may affect the risk of hip fracture, but previous studies have reported inconsistent findings. The primary aim of our meta-analysis was to examine and quantify the potential association of dairy product consumption with risk of hip fracture. We searched the databases of PubMed and EMBASE for relevant articles from their inception through April 17, 2017. The final analysis included 10 cohort studies and 8 case-control studies. Random-effects models were used to estimate the pooled risk. Subgroup and dose-response analyses were conducted to explore the relationships between the consumption of milk and the risk of hip fracture. After pooling the data from the included studies, the summary relative risk (RR) for hip fracture for highest versus lowest consumption were 0.91 (95% CI: 0.74-1.12), 0.75 (95% CI: 0.66-0.86), 0.68 (95% CI: 0.61-0. 77), 1.02 (95% CI: 0.93-1.12) for milk, yogurt, cheese, and total dairy products in cohort studies, respectively. Higher milk consumption [Odds ratio (OR), 0.71, 95% CI: 0.55-0. 91] was associated with lower risk of hip fracture for highest versus lowest consumption in case-control studies. After quantifying the specific dose of milk, the summary RR/OR for an increased milk consumption of 200 g/day was 1.00 (95% CI: 0.94-1.07), and 0.89 (95%CI: 0.64-1.24) with significant heterogeneity for cohort and case-control studies, respectively; There was a nonlinear association between milk consumption and hip fracture risk in cohort, and case-control studies. Our findings indicate that consumption of yogurt and cheese was associated with lower risk of hip fracture in cohort studies. However, the consumption of total dairy products and cream was not significantly associated with the risk of hip fracture. There was insufficient evidence to deduce the association between milk consumption and risk of hip fracture. A lower threshold of 200 g/day milk intake may have beneficial effects, whereas the effects of a higher threshold of milk intake are unclear.
Kinon, Merritt D; Nasser, Rani; Nakhla, Jonathan P; Adogwa, Owoicho; Moreno, Jessica R; Harowicz, Michael; Verla, Terence; Yassari, Reza; Bagley, Carlos A
2016-01-01
The surgical treatment of adult scoliosis frequently involves long segment fusions across the lumbosacral joints that redistribute tremendous amounts of force to the remaining mobile spinal segments as well as to the pelvis and hip joints. Whether or not these forces increase the risk of femoral bone pathology remains unknown. The aim of this study is to determine the correlation between long segment spinal fusions to the pelvis and the antecedent development of degenerative hip pathologies as well as what predictive patient characteristics, if any, correlate with their development. A retrospective chart review of all long segment fusions to the pelvis for adult degenerative deformity operated on by the senior author at the Duke Spine Center from February 2008 to March 2014 was undertaken. Enrolment criteria included all available demographic, surgical, and clinical outcome data as well as pre and postoperative hip pathology assessment. All patients had prospectively collected outcome measures and a minimum 2-year follow-up. Multivariable logistic regression analysis was performed comparing the incidence of preoperative hip pain and antecedent postoperative hip pain as a function of age, gender, body mass index (BMI), and number of spinal levels fused. In total, 194 patients were enrolled in this study. Of those, 116 patients (60%) reported no hip pain prior to surgery. Eighty-three patients (71.6%) remained hip pain free, whereas 33 patients (28.5%) developed new postoperative hip pain. Age, gender, and BMI were not significant among those who went on to develop hip pain postoperatively ( P < 0.0651, 0.3491, and 0.1021, respectively). Of the 78 patients with preoperative hip pain, 20 patients (25.6%) continued to have hip pain postoperatively, whereas 58 patients reported improvement in the hip pain after long segment fusion for correction of their deformity, a 74.4% rate of reduction. Age, gender, and BMI were not significant among those who continued to have hip pain postoperatively ( P < 0.4386, 0.4637, and 0.2545, respectively). Number of levels fused was not a significant factor in the development of hip pain in either patient population; patients without preoperative pain who developed pain postoperatively ( P < 0.1407) as well as patients with preoperative pain who continued to have pain postoperatively ( P < 0.0772). This study demonstrates that long segment lumbosacral fusions are not associated with an increase in postoperative hip pathology. Age, gender, BMI, and levels fused do not correlate with the development of postoperative hip pain. The restoration of spinal alignment with long segment fusions may actually decrease the risk of developing femoral bone pathology and have a protective effect on the hip.
Domb, Benjamin G; Jackson, Timothy J; Carter, Christopher C; Jester, Jon R; Finch, Nathan A; Stake, Christine E
2014-07-01
American football players have an increased level of risk for hip injuries because of the high level of contact, biomechanical load, and anatomic strain placed on the hip joint. Many injuries are attributed to soft tissue injury rather than intra-articular lesions. However, because of improved imaging and increased knowledge, physicians are attributing unexplained hip pain to intra-articular lesions with increasing frequency. To assess the prevalence of pathologic intra-articular hip lesions in a younger, retired National Football League (NFL) player cohort evaluated for persistent hip pain. Case series; Level of evidence, 4. A retrospective chart review was performed of magnetic resonance imaging (MRI) on retired NFL players evaluated at an orthopaedic clinic for persistent hip pain. All MRIs were performed at the same location and reviewed by the same independent radiologist. The study included 62 hips; MRI was used to evaluate 27 hips, and MRI arthrogram was used to evaluate 35 hips. Images were assessed for labral tears, chondral lesions, ligamentum teres (LT) tears, bone cysts, osteophytes, loose bodies, trochanteric bursitis, and alpha angle. Player demographics, including position and seasons played, were recorded. From February 2011 to December 2012, a total of 50 retired players from the NFL (average age, 33 years; range, 27-39 years) received impairment evaluations assessing all symptomatic joints. Thirty-eight (76%) players had hip complaints and underwent a dedicated hip MRI. Twenty-four players (63%) had bilateral hip pain, for a total of 62 hips evaluated. There were 55 (89%) labral tears, 61 (98%) chondral lesions, and 50 (81%) partial or complete LT tears identified on MRI. Additional findings included 3 (5%) hips with osteophytes, 9 (14.5%) with subchondral bone cysts, and 3 (5%) with paralabral cysts. None of the players were found to have trochanteric bursitis or loose bodies. Fifty-eight of 62 alpha angles could be measured, for a mean of 59° (range, 39°-77°). The majority of players were defensive players (63%), while the remainder were offensive players (34%) and 1 special teams player. Position breakdown was as follows: 29% were defensive backs, 16% played the defensive line, 18% were linebackers, 13% were fullbacks, 11% were wide receivers, 5% played the offensive line, and the remaining 8% were kickers, running backs, and quarterbacks. This study demonstrated a high incidence of intra-articular pathologic lesions of the hip in a younger cohort of retired NFL players. The majority of players had bilateral hip pain. The most common finding was chondral lesions, followed by labral tears. Future research is needed to further elucidate incidence and treatment outcomes using prospective studies examining active and retired players with hip-related injuries. © 2014 The Author(s).
Coppack, Russell J; Bilzon, James L; Wills, Andrew K; McCurdie, Ian M; Partridge, Laura K; Nicol, Alastair M; Bennett, Alexander N
2016-01-01
Background There are no studies describing the clinical outcomes of a residential, multidisciplinary team (MDT) rehabilitation intervention for patients with prearthritic hip pain. The aim of this cohort study was to describe the functional and physical outcomes of multidisciplinary residential rehabilitation for UK military personnel with prearthritic hip pain. Methods Participants (N=40) with a mean age of 33 years referred to a specialist residential rehabilitation centre completed a comprehensive multidisciplinary residential intervention. The main outcome measures were mean pain, physical function (modified shuttle test (MST) and Y-balance test), hip range of motion (HROM) and a patient-reported outcome measure (The Copenhagen Hip and Groin Outcome Score, HAGOS). All scores for symptomatic hips were taken at baseline and post-treatment. Results There were improvements in the Y-balance test and HROM following rehabilitation. There were significant improvements in mean difference (T1-to-T2) for Y-balance scores (15.8 cm, 95% CI 10.7 to 20.9, p<0.001), HROM (6.5° increase in hip flexion, 95% CI 4.6 to 9.4, p<0.001) and hip internal rotation (4.6°, 95% CI 2.7 to 6.6, p<0.001). Scores for HAGOS, pain, MST and functional activity assessment showed no improvement. Conclusions Among UK military personnel with prearthritic hip pain, MDT residential rehabilitation resulted in improvements in a functional Y-balance test, hip flexion and internal rotation. The study suggests short-term benefits across some outcomes for the current UK military approach to MDT residential rehabilitation. PMID:27900174
Coppack, Russell J; Bilzon, James L; Wills, Andrew K; McCurdie, Ian M; Partridge, Laura K; Nicol, Alastair M; Bennett, Alexander N
2016-01-01
There are no studies describing the clinical outcomes of a residential, multidisciplinary team (MDT) rehabilitation intervention for patients with prearthritic hip pain. The aim of this cohort study was to describe the functional and physical outcomes of multidisciplinary residential rehabilitation for UK military personnel with prearthritic hip pain. Participants (N=40) with a mean age of 33 years referred to a specialist residential rehabilitation centre completed a comprehensive multidisciplinary residential intervention. The main outcome measures were mean pain, physical function (modified shuttle test (MST) and Y-balance test), hip range of motion (HROM) and a patient-reported outcome measure (The Copenhagen Hip and Groin Outcome Score, HAGOS). All scores for symptomatic hips were taken at baseline and post-treatment. There were improvements in the Y-balance test and HROM following rehabilitation. There were significant improvements in mean difference (T1-to-T2) for Y-balance scores (15.8 cm, 95% CI 10.7 to 20.9, p<0.001), HROM (6.5° increase in hip flexion, 95% CI 4.6 to 9.4, p<0.001) and hip internal rotation (4.6°, 95% CI 2.7 to 6.6, p<0.001). Scores for HAGOS, pain, MST and functional activity assessment showed no improvement. Among UK military personnel with prearthritic hip pain, MDT residential rehabilitation resulted in improvements in a functional Y-balance test, hip flexion and internal rotation. The study suggests short-term benefits across some outcomes for the current UK military approach to MDT residential rehabilitation.
Ripamonti, C; Lisi, L; Avella, M
2014-05-01
To investigate the specificity of the neck shaft angle (NSA) to predict hip fracture in males. We consecutively studied 228 males without fracture and 38 with hip fracture. A further 49 males with spine fracture were studied to evaluate the specificity of NSA for hip-fracture prediction. Femoral neck (FN) bone mineral density (FN-BMD), NSA, hip axis length and FN diameter (FND) were measured in each subject by dual X-ray absorptiometry. Between-mean differences in the studied variables were tested by the unpaired t-test. The ability of NSA to predict hip fracture was tested by logistic regression. Compared with controls, FN-BMD (p < 0.01) was significantly lower in both groups of males with fractures, whereas FND (p < 0.01) and NSA (p = 0.05) were higher only in the hip-fracture group. A significant inverse correlation (p < 0.01) was found between NSA and FN-BMD. By age-, height- and weight-corrected logistic regression, none of the tested geometric parameters, separately considered from FN-BMD, entered the best model to predict spine fracture, whereas NSA (p < 0.03) predicted hip fracture together with age (p < 0.001). When forced into the regression, FN-BMD (p < 0.001) became the only fracture predictor to enter the best model to predict both fracture types. NSA is associated with hip-fracture risk in males but is not independent of FN-BMD. The lack of ability of NSA to predict hip fracture in males independent of FN-BMD should depend on its inverse correlation with FN-BMD by capturing, as the strongest fracture predictor, some of the effects of NSA on the hip fracture. Conversely, NSA in females does not correlate with FN-BMD but independently predicts hip fractures.
Lisi, L; Avella, M
2014-01-01
Objective: To investigate the specificity of the neck shaft angle (NSA) to predict hip fracture in males. Methods: We consecutively studied 228 males without fracture and 38 with hip fracture. A further 49 males with spine fracture were studied to evaluate the specificity of NSA for hip-fracture prediction. Femoral neck (FN) bone mineral density (FN-BMD), NSA, hip axis length and FN diameter (FND) were measured in each subject by dual X-ray absorptiometry. Between-mean differences in the studied variables were tested by the unpaired t-test. The ability of NSA to predict hip fracture was tested by logistic regression. Results: Compared with controls, FN-BMD (p < 0.01) was significantly lower in both groups of males with fractures, whereas FND (p < 0.01) and NSA (p = 0.05) were higher only in the hip-fracture group. A significant inverse correlation (p < 0.01) was found between NSA and FN-BMD. By age-, height- and weight-corrected logistic regression, none of the tested geometric parameters, separately considered from FN-BMD, entered the best model to predict spine fracture, whereas NSA (p < 0.03) predicted hip fracture together with age (p < 0.001). When forced into the regression, FN-BMD (p < 0.001) became the only fracture predictor to enter the best model to predict both fracture types. Conclusion: NSA is associated with hip-fracture risk in males but is not independent of FN-BMD. Advances in knowledge: The lack of ability of NSA to predict hip fracture in males independent of FN-BMD should depend on its inverse correlation with FN-BMD by capturing, as the strongest fracture predictor, some of the effects of NSA on the hip fracture. Conversely, NSA in females does not correlate with FN-BMD but independently predicts hip fractures. PMID:24678889
Varghese, Joy; Sachan, Deepti; Reddy, Mettu S.; Cherian, Tom; Jothimani, Dinesh; Venugopal, Kota; Arikichenin, Olithselvan; Perumalla, Rajasekar; Narasimhan, Gomathy; Shanmugam, Vivekananthan; Vijaya, Srinivasan; Venkataraman, Jayanthi; Rela, Mohamed
2014-01-01
Background Prophylaxis with hepatitis B immunoglobulin (HBIG) and nucleoside analogs can prevent hepatitis B virus (HBV) recurrence after liver transplant (LT). Aim To determine the efficacy and cost of maintaining immunoprophylaxis with HBIG and hyperimmune plasma (HIP) for 6 months after LT. Material & methods The study included 22 HBV related LT recipients who were on entecavir and either HBIG or HIP for 6 months. Post transplant HBIG or HIP dose and cost incurred towards prophylaxis were noted. The cost of 200 IU of HBIG at the time of study was Rs 8250/- (US Dollars 135) and that of 2000 IU of HIP was Rs 8000/- (USD 130.7). The loading and maintenance costs at end of 6 months were compared between the two groups. Response to HBIG and HIP was assessed by checking for HBsAg reactivity, anti HBs titer response and HBV DNA viral load. Statistical analysis Median and range, Kruskal Wallis (KW) sign rank Sum Test and Correlation Coefficient (r2) was used for analysis. Results Thirteen recipients received HBIG and 9 recipients HIP. The anti HBs response to HIP was significantly high compared to HBIG (KW Sign rank Sum test P < 0.05); titers remained high until the study period. Between 8 and 30 days, the titer achieved by both HBIG and HIP was similar (KW Sign rank Sum test not significant). Despite low anti HBs titer of <100 IU/L, none of the recipients on HBIG had HBsAg reactivity while 3 on HIP had transient HBsAg positivity. The total cost with HBIG was 13.9 times the cost of HIP. Conclusion HIP immunoprophylaxis in combination with entecavir achieves a high anti HBs titer at a significant low cost during anhepatic and loading phase. HBV reactivation rates with HBIG and HIP is low despite low anti HBs titer. PMID:25755562
Kemp, Joanne L; Risberg, May Arna; Schache, Anthony G; Makdissi, Michael; Pritchard, Michael G; Crossley, Kay M
2016-11-01
Study Design Cross-sectional study. Background Functional task performance in patients with chondrolabral pathology following hip arthroscopy is unknown. Objectives To investigate in people with chondrolabral pathology following hip arthroscopy (1) the bilateral differences in functional task performance compared to controls, (2) the association of hip muscle strength with functional task performance, and (3) the association of functional task performance scores with good outcome, as measured by International Hip Outcome Tool score. Methods Seventy-one patients who had unilateral hip arthroscopy for hip pain and 60 controls were recruited. Patient-reported outcomes included the 4 subscales of the International Hip Outcome Tool. Hip muscle strength measures included abduction, adduction, extension, flexion, external rotation, and internal rotation. Functional tasks assessed included the single hop test, the side bridge test, and the single-leg rise test. For aim 1, analyses of covariance tests were used. For aim 2, stepwise multiple linear regression analyses were used. For aim 3, receiver operating characteristic curve analyses were used. Results Compared to controls, the chondrolabral pathology group had significantly worse performance on both legs for each of the functional tasks (P<.001). Greater hip abduction strength was moderately associated with better performance on functional tasks in the chondrolabral pathology group (adjusted R 2 range, 0.197-0.407; P<.001). Cutoff values associated with good outcome were 0.37 (hop distance/height) for the single hop, 16 repetitions for the single-leg rise, and 34 seconds for the side bridge test. Conclusion Patients with hip chondrolabral pathology had reduced functional task performance bilaterally 12 to 24 months after unilateral hip arthroscopy when compared to controls. Level of Evidence Therapy/symptom prevalence, level 3b. J Orthop Sports Phys Ther 2016;46(11):947-956. doi:10.2519/jospt.2016.6577.
Varghese, Joy; Sachan, Deepti; Reddy, Mettu S; Cherian, Tom; Jothimani, Dinesh; Venugopal, Kota; Arikichenin, Olithselvan; Perumalla, Rajasekar; Narasimhan, Gomathy; Shanmugam, Vivekananthan; Vijaya, Srinivasan; Venkataraman, Jayanthi; Rela, Mohamed
2014-09-01
Prophylaxis with hepatitis B immunoglobulin (HBIG) and nucleoside analogs can prevent hepatitis B virus (HBV) recurrence after liver transplant (LT). To determine the efficacy and cost of maintaining immunoprophylaxis with HBIG and hyperimmune plasma (HIP) for 6 months after LT. The study included 22 HBV related LT recipients who were on entecavir and either HBIG or HIP for 6 months. Post transplant HBIG or HIP dose and cost incurred towards prophylaxis were noted. The cost of 200 IU of HBIG at the time of study was Rs 8250/- (US Dollars 135) and that of 2000 IU of HIP was Rs 8000/- (USD 130.7). The loading and maintenance costs at end of 6 months were compared between the two groups. Response to HBIG and HIP was assessed by checking for HBsAg reactivity, anti HBs titer response and HBV DNA viral load. Median and range, Kruskal Wallis (KW) sign rank Sum Test and Correlation Coefficient (r2) was used for analysis. Thirteen recipients received HBIG and 9 recipients HIP. The anti HBs response to HIP was significantly high compared to HBIG (KW Sign rank Sum test P < 0.05); titers remained high until the study period. Between 8 and 30 days, the titer achieved by both HBIG and HIP was similar (KW Sign rank Sum test not significant). Despite low anti HBs titer of <100 IU/L, none of the recipients on HBIG had HBsAg reactivity while 3 on HIP had transient HBsAg positivity. The total cost with HBIG was 13.9 times the cost of HIP. HIP immunoprophylaxis in combination with entecavir achieves a high anti HBs titer at a significant low cost during anhepatic and loading phase. HBV reactivation rates with HBIG and HIP is low despite low anti HBs titer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pointer, William David; Shaver, Dillon; Liu, Yang
The U.S. Department of Energy, Office of Nuclear Energy charges participants in the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program with the development of advanced modeling and simulation capabilities that can be used to address design, performance and safety challenges in the development and deployment of advanced reactor technology. The NEAMS has established a high impact problem (HIP) team to demonstrate the applicability of these tools to identification and mitigation of sources of steam generator flow induced vibration (SGFIV). The SGFIV HIP team is working to evaluate vibration sources in an advanced helical coil steam generator using computational fluidmore » dynamics (CFD) simulations of the turbulent primary coolant flow over the outside of the tubes and CFD simulations of the turbulent multiphase boiling secondary coolant flow inside the tubes integrated with high resolution finite element method assessments of the tubes and their associated structural supports. This report summarizes the demonstration of a methodology for the multiphase boiling flow analysis inside the helical coil steam generator tube. A helical coil steam generator configuration has been defined based on the experiments completed by Polytecnico di Milano in the SIET helical coil steam generator tube facility. Simulations of the defined problem have been completed using the Eulerian-Eulerian multi-fluid modeling capabilities of the commercial CFD code STAR-CCM+. Simulations suggest that the two phases will quickly stratify in the slightly inclined pipe of the helical coil steam generator. These results have been successfully benchmarked against both empirical correlations for pressure drop and simulations using an alternate CFD methodology, the dispersed phase mixture modeling capabilities of the open source CFD code Nek5000.« less
Larson, Christopher M; Pierce, Bradley R; Giveans, M Russell
2011-06-01
The purpose of the study was to evaluate the results of surgical treatment in athletes with associated intra-articular hip pathology and extra-articular sports pubalgia. Between December 2003 and September 2009, 37 hips (mean patient age, 25 years) were diagnosed with both symptomatic athletic pubalgia and symptomatic intra-articular hip joint pathology. There were 8 professional athletes, 15 collegiate athletes, 5 elite high school athletes, and 9 competitive club athletes. Outcomes included an evaluation regarding return to sports and modified Harris Hip Score, Short Form 12 score, and visual analog scale score. We evaluated 37 hips at a mean of 29 months (range, 12 to 78 months) after the index surgery. Thirty-one hips underwent thirty-five athletic pubalgia surgeries. Hip arthroscopy was performed in 32 hips (30 cases of femoroacetabular impingement treatment, 1 traumatic labral tear, and 1 borderline dysplasia). Of 16 hips that had athletic pubalgia surgery as the index procedure, 4 (25%) returned to sports without limitations, and 11 (69%) subsequently had hip arthroscopy at a mean of 20 months after pubalgia surgery. Of 8 hips managed initially with hip arthroscopy alone, 4 (50%) returned to sports without limitations, and 3 (43%) had subsequent pubalgia surgery at a mean of 6 months after hip arthroscopy. Thirteen hips had athletic pubalgia surgery and hip arthroscopy at one setting. Concurrent or eventual surgical treatment of both disorders led to improved postoperative outcomes scores (P < .05) and an unrestricted return to sporting activity in 89% of hips (24 of 27). When surgery only addressed either the athletic pubalgia or intra-articular hip pathology in this patient population, outcomes were suboptimal. Surgical management of both disorders concurrently or in a staged manner led to improved postoperative outcomes scoring and an unrestricted return to sporting activity in 89% of hips. Level IV, therapeutic case series. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Salmingo, Remel Alingalan; Skytte, Tina Lercke; Traberg, Marie Sand; Mikkelsen, Lars Pilgaard; Henneberg, Kaj-Åge; Wong, Christian
2017-01-01
Perthes' disease is a destructive hip joint disorder characterized by malformation of the femoral head in young children. While the morphological changes have been widely studied, the biomechanical effects of these changes still need to be further elucidated. The objective of this study was to develop a method to investigate the biomechanical alterations in Perthes' disease by finite element (FE) contact modeling using MRI. The MRI data of a unilateral Perthes' case was obtained to develop the three-dimensional FE model of the hip joint. The stress and contact pressure patterns in the unaffected hip were well distributed. Elevated concentrations of stress and contact pressure were found in the Perthes' hip. The highest femoral cartilage von Mises stress 3.9 MPa and contact pressure 5.3 MPa were found in the Perthes' hip, whereas 2.4 MPa and 4.9 MPa in the healthy hip, respectively. The healthy bone in the femoral head of the Perthes' hip carries additional loads as indicated by the increase of stress levels around the necrotic-healthy bone interface. Identifying the biomechanical changes, such as the location of stress and contact pressure concentrations, is a prerequisite for the preoperative planning to obtain stress relief for the highly stressed areas in the malformed hip. This single-patient study demonstrated that the biomechanical alterations in Perthes' disease can be evaluated individually by patient-specific finite element contact modeling using MRI. A multi-patient study is required to test the strength of the proposed method as a pre-surgery planning tool.
Kamath, M Ganesh; Prakash, Jay; Dash, Sambit; Chowdhury, Sudipta; Ahmed, Zuhilmi Bin; Yusof, Muhammad Zaim Zharif Bin Mohd
2014-09-01
Sleep is vital for mental and physical health of an individual. Duration of sleep influences the metabolism and regulates body weight. To assess the cross-sectional association of sleep duration with body mass index (BMI) and waist-hip ratio in Malaysian students. Eighty-nine Malaysian students of both genders, and with a mean (standard deviation) age of 21.2 (0.9) years were included. Institutional Ethics Committee clearance was obtained prior to the start of study. The subjects were interviewed regarding the average hours of sleep/day, their self-reported sleep duration was categorized as < 6hour/day (short sleep duration), 6-7hour/day and > 7hour/day. Their height (in meters), weight (in kilograms), waist and hip circumference (in centimetre) were measured. BMI and waist-hip ratio were calculated using appropriate formulas and expressed as mean (standard deviation). The duration of sleep was compared with BMI and waist-hip ratio using one way ANOVA. No statistical significance was observed when sleep duration was associated with BMI (p=0.65) and waist-hip ratio (p=0.95). Duration of sleep did not affect BMI and waist hip ratio in the Malaysian students in our study. The age and healthy lifestyle of the subjects in this study may have been a reason for no significant influence of short sleep duration on the BMI and waist-hip ratio. No association was found between sleep duration with BMI and waist hip ratio in the Malaysian students.
Wang, Ruoli; Gutierrez-Farewik, Elena M
2014-03-01
Excessive co-contraction causes inefficient or abnormal movement in several neuromuscular pathologies. How synergistic muscles spanning the ankle, knee and hip adapt to co-contraction of ankle muscles is not well understood. This study aimed to identify the compensation strategies required to retain normal walking with excessive antagonistic ankle muscle co-contraction. Muscle-actuated simulations of normal walking were performed to quantify compensatory mechanisms of ankle and knee muscles during stance in the presence of normal, medium and high levels of co-contraction of antagonistic pairs gastrocnemius+tibialis anterior and soleus+tibialis anterior. The study showed that if co-contraction increases, the synergistic ankle muscles can compensate; with gastrocmemius+tibialis anterior co-contraction, the soleus will increase its contribution to ankle plantarflexion acceleration. At the knee, however, almost all muscles spanning the knee and hip are involved in compensation. We also found that ankle and knee muscles alone can provide sufficient compensation at the ankle joint, but hip muscles must be involved to generate sufficient knee moment. Our findings imply that subjects with a rather high level of dorsiflexor+plantarflexor co-contraction can still perform normal walking. This also suggests that capacity of other lower limb muscles to compensate is important to retain normal walking in co-contracted persons. The compensatory mechanisms can be useful in clinical interpretation of motion analyses, when secondary muscle co-contraction or other deficits may present simultaneously in subjects with motion disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
Effect of consolidation on adhesive and abrasive wear of ultra high molecular weight polyethylene.
Gul, Rizwan M; McGarry, Frederick J; Bragdon, Charles R; Muratoglu, Orhun K; Harris, William H
2003-08-01
Total hip replacement (THR) is widely performed to recover hip joint functions lost by trauma or disease and to relieve pain. The major cause of failure in THR is the wear of the ultra high molecular weight polyethylene (UHMWPE) component. The dominant wear mechanism in THR occurs through adhesion and abrasion. While poor consolidation of UHMWPE is known to increase the incidence of a different damage mode, delamination, which is the dominant wear mechanism in tibial inserts but uncommon in THR, the effect of consolidation on adhesive and abrasive wear of UHMWPE is not clear. In this study UHMWPE resin was subjected to hot isostatic pressing under a pressure of 138MPa at different temperatures (210 degrees C, 250 degrees C, and 300 degrees C) to achieve varying degrees of consolidation. The extent of consolidation was determined by optical microscopy using thin sections, and by scanning electron microscopy using cryofractured and solvent etched specimens. Wear behavior of the samples with varying degree of consolidation was determined using a bi-directional pin-on-disc machine simulating conditions in a hip joint. Increasing the processing temperature decreased the incidence of fusion defects and particle boundaries reflecting the powder flakes of the virgin resin, improving the consolidation. However, the bi-directional pin-on-disc wear rate did not change with the processing temperature, indicating that adhesive and abrasive wear is independent of the extent of consolidation in the range of parameters studied here.
Jung, Hun Jae; Yoon, Ji Yeon; Oh, Min Kyung; Kim, Young Chang; Kim, Jae Hyun; Eom, Tae Woong; Park, Kun Bo
2016-06-01
There are several different opinions regarding the improvements seen on the transverse plane after soft tissue surgery alone in independently ambulant patients with cerebral palsy. We performed a meta-analysis using data from previous studies to identify the effects of soft tissue surgery alone on pelvic and hip rotation in children with spastic diplegia. We conducted a pilot study to evaluate the improvement in pelvic and hip rotation after muscle-tendon lengthening surgery in children with spastic diplegia. We also searched EMBASE and PubMed and selected 2 previous studies using the same test conditions with kinematic data on the pelvis and hip joints. A meta-analysis of the results of these 3 studies, including this pilot study, was then performed. The meta-analysis results showed an external rotation decrease (p = 0.005) in the mean difference of pelvic rotation of -3.61 (95% confidence interval [CI], -6.13 to -1.09) and a mean difference in hip rotation of 6.60 (95% CI, 3.34 to 9.86), indicating a significant increase in the hip external rotation after surgery (p < 0.001). In independently community-ambulant pediatric patients with spastic diplegia, pelvic retraction and hip internal rotation could be improved after soft tissue surgery.
Deasy, Margaret; Leahy, Edmund; Semciw, Adam Ivan
2016-08-01
Study Design Systematic review with meta-analysis. Background A complete understanding of impairments associated with knee osteoarthritis would optimize exercise interventions for people with knee osteoarthritis. Our current understanding of hip strength deficits in this population is based on studies with conflicting findings and small samples. There is a need to systematically review and pool current evidence. Objectives To determine whether hip strength deficits exist in people with symptomatic knee osteoarthritis. Methods Electronic databases (MEDLINE, CINAHL, Embase, the Cochrane Library, and PsycINFO) were searched through February 2016. Studies comparing hip strength in people diagnosed with symptomatic knee osteoarthritis to healthy control participants were included in the review. A meta-analysis with random effects was applied to relevant data from included studies and a modified Grading of Recommendations Assessment, Development and Evaluation approach was used to evaluate the quality of evidence for each pooled analysis. Results Five studies were included in the review. Meta-analysis revealed moderate-quality evidence of weaker isometric and isokinetic hip abduction strength in people with knee osteoarthritis (moderate difference: 7% to 24% weaker) and very low-quality evidence of no difference in isometric hip adduction strength. There was very low- to moderate-quality evidence of weaker isokinetic hip strength in the remaining planes of motion (moderate to large differences: 14% to 55% weaker). Conclusion Significant hip strength deficits exist in people with knee osteoarthritis. Hip strength assessment should be considered in clinical practice and may assist with directing targeted management strategies. Level of Evidence Symptom prevalence, level 1a-. J Orthop Sports PhysTher 2016;46(8):629-639. Epub3 Jul 2016. doi:10.2519/jospt.2016.6618.
Risberg, May Arna; Ageberg, Eva; Nilstad, Agnethe; Lund, Bent; Nordsletten, Lars; Løken, Sverre; Ludvigsen, Tom; Kierkegaard, Signe; Carsen, Sasha; Kostogiannis, Ioannis; Crossley, Kay M; Glyn-Jones, Sion; Kemp, Joanne L
2018-04-01
Study Design Study protocol for a randomized controlled trial and a prospective cohort. Background The number of arthroscopic surgical procedures for patients with femoroacetabular impingement syndrome (FAIS) has significantly increased worldwide, but high-quality evidence of the effect of such interventions is lacking. Objectives The primary objective will be to determine the efficacy of hip arthroscopic procedures compared to sham surgery on patient-reported outcomes for patients with FAIS (HIP ARThroscopy International [HIPARTI] Study). The secondary objective will be to evaluate prognostic factors for long-term outcome after arthroscopic surgical interventions in patients with FAIS (Hip ARthroscopy Prospective [HARP] Study). Methods The HIPARTI Study will include 140 patients and the HARP Study will include 100 patients. The international Hip Outcome Tool-33 will be the primary outcome measure at 1 year. Secondary outcome measures will be the Hip disability and Osteoarthritis Outcome Score, Arthritis Self-Efficacy Scale, fear of movement (Tampa Scale of Kinesiophobia), Patient-Specific Functional Scale, global rating of change score, and expectations. Other outcomes will include active hip range of motion, hip muscle strength tests, functional performance tests, as well as radiological assessments using radiographs and magnetic resonance imaging. Conclusion To determine the true effect of surgery, beyond that of placebo, double-blinded placebo-controlled trials including sham surgery are needed. The HIPARTI Study will direct future evidence-based treatment of FAIS. Predictors for long-term development and progression of degenerative changes in the hip are also needed for this young patient group with FAIS; hence, responders and nonresponders to treatment could be determined. J Orthop Sports Phys Ther 2018;48(4):325-335. doi:10.2519/jospt.2018.7931.
Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.
Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf
2018-07-01
Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.
Poulsen, Erik; Christensen, Henrik W; Overgaard, Søren; Hartvigsen, Jan
2012-05-01
The purposes of this study were to measure the prevalence of clinical and radiographic hip osteoarthritis (OA) and first-time diagnosis of hip OA in consecutive patients presenting to chiropractic practices in Denmark and to report the components of the initial treatment rendered by the chiropractic practitioner. A total of 2000 patient records and 1000 radiographs were reviewed retrospectively in 20 chiropractic clinics throughout Denmark. Information obtained included patients' primary complaint, physical examination and radiographic findings of hip OA, and treatment. Subsequently, the 20 clinics participated in a prospective survey where they collected equivalent information over a 2-week period. Retrospective review of records revealed that 1.4% of patients in Danish chiropractic practice had signs of clinical hip OA. Of these, 59% demonstrated radiographic signs of hip OA. Prospective data collection revealed that 3.4% of new patients had signs of clinical hip OA. Fifty-four percent of these demonstrated radiographic signs of hip OA, and of these 70% were diagnosed as having OA of the hip for the first time. Initial treatment involved manual treatment and advice on over-the-counter pain medication and/or supplements. Of all 1000 retrospectively reviewed radiographs in patients 40 years or older, 19.2% demonstrated radiographic signs of hip OA. Osteoarthritis of the hip is diagnosed and managed in primary care chiropractic practice in Denmark; however, it is likely underdiagnosed. In those newly presenting to chiropractic practitioners, first-time diagnosis with clinical and radiographic signs of hip OA appears to be common. Copyright © 2012 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Physical activity of elderly patients after total hip arthroplasty.
Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna
2007-01-01
Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.
Shum, Gary L K; Crosbie, Jack; Lee, Raymond Y W
2005-09-01
Experimental study to describe lumbar spine and hip joint movements during sit-to-stand and stand-to-sit. To examine differences in the kinematics and joint coordination of the lumbar spine and hips during sit-to-stand and stand-to-sit between healthy subjects and patients with subacute low back pain (LBP). There is a paucity of information on the coordination of movements of lumbar spine and hips during sit-to-stand and stand-to-sit. The effect of LBP, with or without nerve root signs, is largely unknown. A three-dimensional real-time electromagnetic tracking device was used to measure movements of the lumbar spine and hips during sit-to-stand and stand-to-sit. Sixty subacute LBP participants with or without straight leg raise signs and 20 healthy asymptomatic participants were recruited. The kinematic patterns of lumbar spine and hips were analyzed. Coordination between the two joints was studied by relative phase angle analysis. The mobility of the spine and hips was significantly limited in back pain subjects. It was observed that LBP subjects employed various strategies to compensate for the limited motions at the hips and lumbar spine. The contribution of the lumbar spine relative to that of the hip was found to be reduced for subjects with LBP. The lumbar spine-hip joint coordination was significantly altered in back pain subjects, in particular, those with positive straight leg raise sign. Back pain was related to changes in the kinematics and coordination of the lumbar spine and hips during sit-to-stand and stand-to-sit. Assessment of back pain patients should include kinematic analysis of the hips as well as the spine.
Descriptive profile of hip range of motion in elite tennis players.
Moreno-Pérez, Victor; Ayala, Francisco; Fernandez-Fernandez, Jaime; Vera-Garcia, Francisco J
2016-05-01
To describe the range of motion (ROM) profile (flexion, extension, abduction, internal and external rotation) of the hip in elite tennis players; and (b) to analyse if there are sex-related differences in the hip ROM. Cohort study. Controlled laboratory environment. 81 male and 28 female tennis players completed this study. Descriptive measures of passive hip flexion, extension and abduction, and internal and external active and passive hip rotation ROM were taken. Magnitude-based inferences on differences between sex (males vs. females) and hip (dominant vs. non-dominant) were made by standardising differences. No clinically meaningful bilateral and sex-related differences in any of the hip ROM measures. In addition, it was found that both males and females had restricted mobility measures on hip flexion (<80°), extension (<0°) and abduction (<40°). Furthermore, the 30% of males also presented restricted active and passive hip internal rotation ROM values (<25°). Finally, both males and females had normal mobility measures of hip external rotation ROM (active [>25°] and passive [35°]) Asymmetric hip joint ROM measures found during clinical examination and screening may indicate abnormalities and the need of rehabilitation (e.g., flexibility training). In addition, clinicians should include specific exercises (e.g., stretching) in their conditioning, prevention and rehabilitation programmes aiming to avoid restricted mobility of hip flexion (males = 74°; females = 78°), extension (males = -1.5; females = -0.4), abduction (males = 35°; females = 34°) and internal rotation (males = 30°; females = 35) that might be generated as a consequence of playing tennis. Copyright © 2015 Elsevier Ltd. All rights reserved.
The effect of soft tissue release of the hips on walking in myelomeningocele.
Correll, J; Gabler, C
2000-06-01
Walking and standing capacity in myelomeningocele is highly dependent on the level of the neurological lesion. Deformities, mainly flexion deformities, of the hip can severely interfere with mobility. In a retrospective study, undertaken in our hospital, we evaluated the role of soft tissue release of the hip in patients with hip flexion contractures. A special surgical technique was performed in 55 hips. The results show a good effect on verticalization, even if the hip joints cannot be extended actively. A subluxated or dislocated hip did not influence the final outcome. During the mean follow-up of approximately 4 years, only a slight recurrence of the former deformity was observed. Most of the patients obtained great advantage from the operation.
Subsequent Total Joint Arthroplasty After Primary Total Knee or Hip Arthroplasty
Sanders, Thomas L.; Maradit Kremers, Hilal; Schleck, Cathy D.; Larson, Dirk R.; Berry, Daniel J.
2017-01-01
Background: Despite the large increase in total hip arthroplasties and total knee arthroplasties, the incidence and prevalence of additional contralateral or ipsilateral joint arthroplasty are poorly understood. The purpose of this study was to determine the rate of additional joint arthroplasty after a primary total hip arthroplasty or total knee arthroplasty. Methods: This historical cohort study identified population-based cohorts of patients who underwent primary total hip arthroplasty (n = 1,933) or total knee arthroplasty (n = 2,139) between 1969 and 2008. Patients underwent passive follow-up through their medical records beginning with the primary total hip arthroplasty or total knee arthroplasty. We assessed the likelihood of undergoing a subsequent total joint arthroplasty, including simultaneous and staged bilateral procedures. Age, sex, and calendar year were evaluated as potential predictors of subsequent arthroplasty. Results: During a mean follow-up of 12 years after an initial total hip arthroplasty, we observed 422 contralateral total hip arthroplasties (29% at 20 years), 76 contralateral total knee arthroplasties (6% at 10 years), and 32 ipsilateral total knee arthroplasties (2% at 20 years). Younger age was a significant predictor of contralateral total hip arthroplasty (p < 0.0001), but not a predictor of the subsequent risk of total knee arthroplasty. During a mean follow-up of 11 years after an initial total knee arthroplasty, we observed 809 contralateral total knee arthroplasties (45% at 20 years), 31 contralateral total hip arthroplasties (3% at 20 years), and 29 ipsilateral total hip arthroplasties (2% at 20 years). Older age was a significant predictor of ipsilateral or contralateral total hip arthroplasty (p < 0.001). Conclusions: Patients undergoing total hip arthroplasty or total knee arthroplasty can be informed of a 30% to 45% chance of a surgical procedure in a contralateral cognate joint and about a 5% chance of a surgical procedure in noncognate joints within 20 years of initial arthroplasty. Increased risk of contralateral total knee arthroplasty following an initial total hip arthroplasty may be due to gait changes prior to and/or following total hip arthroplasty. The higher prevalence of bilateral total hip arthroplasty in younger patients may result from bilateral disease processes that selectively affect the young hip, such as osteonecrosis, or structural hip problems, such as acetabular dysplasia or femoroacetabular impingement. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28244910
History and physical examination of hip injuries in elderly adults.
Hamedan Al Maqbali, Mohammed Abdullah
2014-01-01
Hip fracture is the most common injury occurring to elderly people and is associated with restrictions of the activities of the patients themselves. The discovery of a hip fracture can be the beginning of a complex journey of care, from initial diagnosis, through operational procedures to rehabilitation. The patient's history and physical examination form the basis of the diagnosis and monitoring of elderly patients with hip problems and dictate the appropriate treatment strategy to be implemented. The aim of this study is to discuss the different diagnoses of hip pain in a case study of an elderly woman who initially complained of pain in her right knee following a fall at home. It shows that musculoskeletal physical examination determined the management of the hip fracture that was found to be present. In addition, the aim of this article is to review diagnostic tests such as radiographs and recommend appropriate management and treatment of hip fractures in elderly patients.
High-energy extracorporeal shock wave therapy for nontraumatic osteonecrosis of the femoral head.
Xie, Kai; Mao, Yuanqing; Qu, Xinhua; Dai, Kerong; Jia, Qingwei; Zhu, Zhenan; Yan, Mengning
2018-02-02
Nontraumatic osteonecrosis of the femoral head (ONFH) is treated with a series of methods. High-energy extracorporeal shock wave therapy (ESWT) is an option with promising mid-term outcomes. The objective of this study was to determine the long-term outcomes of ESWT for ONFH. Fifty-three hips in 39 consecutive patients were treated with ESWT in our hospital between January 2005 and July 2006. Forty-four hips in 31 patients with stage I-III nontraumatic ONFH, according to the Association Research Circulation Osseous (ARCO) system, were reviewed in the current retrospective study. The visual analog pain scale (VAS), Harris hip score, radiography, and magnetic resonance imaging were used to estimate treatment results. The progression of ONFH was evaluated by imaging examination and clinical outcomes. The results were classified as clinical success (no progression of hip symptoms) and imaging success (no progression of stage or substage on radiography and MRI). The mean follow-up duration was 130.6 months (range, 121 to 138 months). The mean VAS decreased from 3.8 before ESWT to 2.2 points at the 10-year follow-up (p < 0.001). The mean Harris hip score improved from 77.4 before ESWT to 86.9 points at the 10-year follow-up. The clinical success rates were 87.5% in ARCO stage I patients, 71.4% in ARCO stage II patients, and 75.0% in ARCO stage III patients. Imaging success was observed in all stage I hips, 64.3% of stage II hips, and 12.5% of stage III hips. Seventeen hips showed progression of the ARCO stage/substage on imaging examination. Eight hips showed femoral head collapse at the 10-year follow-up. Four hips in ARCO stage III and one hip in ARCO stage II were treated with total hip arthroplasty during the follow-up. Three were performed 1 year after ESWT, one at 2 years, and one at 5 years. The results of the current study indicated that ESWT is an effective treatment method for nontraumatic ONFH, resulting in pain relief and function restoration, especially for patients with ARCO stage I-II ONFH.
Extreme Kinematics in Selected Hip Hop Dance Sequences.
Bronner, Shaw; Ojofeitimi, Sheyi; Woo, Helen
2015-09-01
Hip hop dance has many styles including breakdance (breaking), house, popping and locking, funk, streetdance, krumping, Memphis jookin', and voguing. These movements combine the complexity of dance choreography with the challenges of gymnastics and acrobatic movements. Despite high injury rates in hip hop dance, particularly in breakdance, to date there are no published biomechanical studies in this population. The purpose of this study was to compare representative hip hop steps found in breakdance (toprock and breaking) and house and provide descriptive statistics of the angular displacements that occurred in these sequences. Six expert female hip hop dancers performed three choreographed dance sequences, top rock, breaking, and house, to standardized music-based tempos. Hip, knee, and ankle kinematics were collected during sequences that were 18 to 30 sec long. Hip, knee, and ankle three-dimensional peak joint angles were compared in repeated measures ANOVAs with post hoc tests where appropriate (p<0.01). Peak angles of the breaking sequence, which included floorwork, exceeded the other two sequences in the majority of planes and joints. Hip hop maximal joint angles exceeded reported activities of daily living and high injury sports such as gymnastics. Hip hop dancers work at weight-bearing joint end ranges where muscles are at a functional disadvantage. These results may explain why lower extremity injury rates are high in this population.
Bitar, KM; Ferdhany, ME; Saw, A
2016-01-01
Introduction: Hip spica casting is an important component of treatment for developmental dysplasia of the hip (DDH) and popular treatment method for femur fractures in children. Breakage at the hip region is a relatively common problem of this cast. We have developed a three-slab technique of hip spica application using fibreglass as the cast material. The purpose of this review was to evaluate the physical durability of the spica cast and skin complications with its use. Methodology: A retrospective review of children with various conditions requiring hip spica immobilisation which was applied using our method. Study duration was from 1st of January 2014 until 31st December 2015. Our main outcomes were cast breakage and skin complications. For children with hip instability, the first cast would be changed after one month, and the second cast about two months later. Results: Twenty-one children were included, with an average age of 2.2 years. The most common indication for spica immobilisation was developmental dysplasia of the hip. One child had skin irritation after spica application. No spica breakage was noted. Conclusion: This study showed that the three-slab method of hip spica cast application using fibreglass material was durable and safe with low risk of skin complications. PMID:28553442
Oshikawa, Tomoki; Morimoto, Yasuhiro; Kaneoka, Koji
2018-03-01
[Purpose] To compare the lumbar lordosis angle and electromyographic activities of the trunk and lower-limb muscles in the hip neutral position and external rotation during back squats. [Subjects and Methods] Ten healthy males without severe low back pain or lower-limb injury participated in this study. The lumbar lordosis angle and electromyographic activities were measured using three-dimensional motion-capture systems and surface electrodes during four back squats: parallel back squats in the hip neutral position and external rotation and full back squats in the hip neutral position and external rotation. A paired t-test was used to compare parallel and full back squats measurements in the hip neutral position and external rotation, respectively. [Results] During parallel back squats, the average lumbar lordosis angle was significantly larger in hip external rotation than in the hip neutral position. During full back squats, lumbar erector spinae and multifidus activities were significantly lower in hip external rotation than in the hip neutral position, whereas gluteus maximus activity was significantly higher in hip external rotation than in the hip neutral position. [Conclusion] The back squat in hip external rotation induced improvement of lumbar kyphosis, an increasing of the gluteus maximus activity and a decrease of both lumbar erector spinae and multifidus activities.
Watanabe, Nobuyuki; Iguchi, Hirotaka; Mitsui, Hiroto; Tawada, Kaneaki; Murakami, Satona; Otsuka, Takanobu
2014-01-01
The arthroscopic surgical procedures reported previously for a rheumatic hip joint have been primarily performed as diagnostic procedures. Only a few studies have reported the success of arthroscopic surgery in hip joint preservation. We encountered a special case in which joint remodeling was seen in a patient with rheumatoid arthritis treated with biological drugs after hip arthroscopic synovectomy and labral repair. We report the case of a 39-year-old woman with rheumatism, which was controlled with tocilizumab, prednisolone, and tacrolimus. The hip joint showed Larsen grade 3 destruction, and the Harris Hip Score was 55 points. Because of the patient's strong desire to undergo a hip preservation operation, we performed hip arthroscopic synovectomy and repair of a longitudinal labral tear. After 2.5 years, the joint space had undergone rebuilding with improvement to Larsen grade 2, and the Harris Hip Score had improved to 78 points; the patient was able to return to work with the use of 1 crutch. It is possible to perform hip arthroscopic surgery for rheumatoid arthritis with a hip preservation operation with biological drugs. PMID:25276611
Boo, Marie E.; Garrison, J. Craig; Hannon, Joseph P.; Creed, Kalyssa M.; Goto, Shiho; Grondin, Angellyn N.; Bothwell, James M.
2018-01-01
Background: Female patients are more likely to suffer a second anterior cruciate ligament (ACL) injury after ACL reconstruction (ACLR) and return to sport (RTS) compared with healthy female controls. Few studies have examined the energy absorption contribution (EAC) that could lead to this subsequent injury. Hypothesis: The ACLR group would demonstrate an altered EAC between joints (hip, knee, and ankle) but no difference in quadriceps, hip abduction, or hip external rotation (ER) strength at the time of RTS. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 34 female participants (ACLR: n = 17; control: n = 17) were enrolled in the study and matched for age and activity level. Jump landing performance for the initial 50 milliseconds of landing of a lateral-vertical jump was assessed using a 10-camera 3-dimensional motion capture system and 2 force plates. Isokinetic quadriceps strength was measured using a Biodex machine, and hip abduction and ER isometric strength were measured using a handheld dynamometer. All values were normalized to the participant’s height and weight. A 1-way multivariate analysis of variance was used to assess between-group differences in the EAC at the hip, knee, and ankle. Two 1-way analyses of variance were used to independently examine quadriceps, hip abduction, and hip ER strength between the groups. Results: Significant differences in the EAC were found between the groups for the involved hip (P = .002), uninvolved hip (P = .005), and involved ankle (P = .023). There were no between-group differences in the EAC for the involved or uninvolved knee or the uninvolved ankle. Patients who underwent ACLR demonstrated significantly decreased quadriceps strength on the involved limb (P = .02) and decreased hip ER strength on both the involved (P = .005) and uninvolved limbs (P = .002). No significant strength differences were found between the groups for the uninvolved quadriceps or for involved or uninvolved hip abduction. Conclusion: At RTS, patients who underwent ACLR utilized a greater hip EAC bilaterally and a decreased involved ankle EAC during a lateral-vertical jump. Furthermore, quadriceps strength on the involved limb and hip ER strength of bilateral lower extremities remained decreased. This could place greater stress on the ACL graft and ultimately lead to an increased injury risk. PMID:29552573
Second hip fractures at Chiang Mai University Hospital.
Wongtriratanachai, Prasit; Chiewchantanakit, Siripong; Vaseenon, Tanawat; Rojanasthien, Sattaya; Leerapun, Taninnit
2015-02-01
Hip fractures are a major public health problem. Patients who have suffered a hip fracture have an increased risk of a subsequent hip fracture. This study examines the incidence ofsecondhip fractures and attempts to identify underlying risk factors. To examine the incidence ofsecond hip fractures in osteoporotic patients at Chiang Mai University Hospital and to identify risk factors related to second hip fractures. A retrospective review was conducted of all low-energy mechanism hip fracture patients admitted during 2008 and 2009. Analysis of second hip fractures was conducted using survival analysis and logistic regression analysis. A total of 191 patients were observed for 391.68 person-years (mean 2.05 person-years per patient). Among that group, nine second hip fractures were identified, an overall incidence rate of 0.023 second fractures per person-year. Second hip fractures tended to occur within the first year following an initial hip fracture. There were no significant differences related to either gender or comorbid medical conditions. Logistic regression analysis revealed that increased risk of a second hip fracture was associated with age (highest between 80 to 89 years) and patients who were not treated for osteoporosis following their initial fracture. The incidence of second hip fractures at Chiang Mai University Hospital was 0.023 per person-year Careful follow-up of older patients, especially those over 80, and treatment ofosteoporosis with bisphosphonate plus vitamin D and calcium supplements was correlated with a reduction in the incidence of second hip fractures.
Wyles, Cody C; Norambuena, Germán A; Howe, Benjamin M; Larson, Dirk R; Levy, Bruce A; Yuan, Brandon J; Trousdale, Robert T; Sierra, Rafael J
2017-11-01
The natural history of femoroacetabular impingement (FAI) remains incompletely understood. In particular, there is limited documentation of joint damage in adolescent patients with limited range of motion (LROM) of the hip, which is commonly associated with FAI. To evaluate changes in magnetic resonance imaging (MRI), radiographs, and clinical examinations over 5 years in a group of athletes from a wide variety of sports with asymptomatic LROM of the hip compared with matched controls. Cohort study (prognosis); Level of evidence, 2. The authors screened 226 male and female athletes aged 12 to 18 years presenting for preparticipation sports physical examinations. Using a goniometer, we identified 13 participants with at least one hip having internal rotation <10° with the hip flexed to 90°. Overall, 21 of 26 hips (81%) had internal rotation <10°. These participants were age- and sex-matched to 13 controls with internal rotation >10°. At the time of enrollment, all participants were asymptomatic and underwent a complete hip examination and radiographic imaging with radiographs (anteroposterior [AP] and von Rosen views) and non-arthrogram MRI. Participants returned at 5-year follow-up and underwent repeat hip examinations, imaging (AP and lateral radiographs and non-arthrogram MRI), and hip function questionnaires. MRI scans were classified as "normal" versus "abnormal" based on the presence of any of 13 scored chondral, labral, or osseous abnormalities. Comparisons between the LROM group and control group were performed using generalized linear models (either linear, logistic, or log-binomial regression as appropriate for the outcome) with generalized estimating equations to account for the within-participant correlation due to patients having both hips included. Relative risk (RR) estimates are reported with 95% CIs. At the time of study enrollment, 16 of 26 hips (62%) in the LROM group had abnormal MRI findings within the acetabular labrum or cartilage compared with 8 of 26 hips (31%) in the control group (RR, 2.0; 95% CI, 0.95-4.2; P = .067). The mean alpha angle measured from radial MRI sequences was 58° in the LROM group versus 44° in the control group ( P < .0001). In the LROM group, 13 of 26 hips (50%) had a positive anterior impingement sign, whereas 0 of 26 hips (0%) had a positive anterior impingement sign in the control group. At 5-year follow-up, 18 of 19 hips (95%) in the LROM group had abnormal MRI findings compared with 14 of 26 hips (54%) in the control group (RR, 1.7; 95% CI, 1.1-2.7; P = .014). New or progressive findings were documented on MRI in 15 of 20 hips in the LROM group compared with 8 of 26 hips in the control group (RR, 2.4; 95% CI, 1.2-4.8; P = .011). Six of 22 hips (27%) in the LROM group progressed from Tönnis grade 0 to Tönnis grade 1 in degenerative changes, whereas all 26 hips in the control group remained at Tönnis grade 0 on hip radiographs. In the LROM group, 11 of 22 hips (50%) had a positive anterior impingement sign, whereas 1 of 26 hips (4%) had a positive anterior impingement sign in the control group. A cam deformity (alpha angle >55° on lateral radiographs) was present in 20 of 22 hips (91%) in the LROM group and 12 of 26 hips (46%) in the control group ( P = .0165). The following variables at baseline were associated with an increased risk of degenerative changes at 5-year follow-up for the entire cohort: decreased hip internal rotation, positive anterior impingement sign, decreased hip flexion, increased alpha angle, and presence of a cam lesion. At 5 years, young athletes with LROM of the hip showed increased progressive degenerative changes on MRI and radiographs compared with matched controls. Although the majority of these participants remained asymptomatic, those with features of FAI had radiographic findings consistent with early osteoarthritis. These outcomes suggest that more aggressive screening and counseling of young active patients may be helpful to prevent hip osteoarthritis in those with FAI.
Effect of month of birth on hip dysplasia in labrador retrievers and Gordon setters.
Wood, J L N; Lakhani, K H
2003-01-18
Recent studies have proposed selective breeding policies for preventing or controlling hip dysplasia, based upon the relationships between the hip scores of the offspring and their parents. However, these studies have ignored the possible effects on an animal's hip score of its age when it was examined and the month in which it was born. This paper describes the results of statistical analyses of large data sets of Kennel Club-registered labrador retrievers and Gordon setters. Regression modelling showed that an animal's hip score depended significantly upon the hip score of its sire and dam, and upon its month of birth. Enlarging the model by including its age when examined made it possible to quantify the significant genetic parental effects and the effects of the animal's month of birth and its age when examined.
Effects of preoperative physiotherapy in hip osteoarthritis patients awaiting total hip replacement
Czyżewska, Anna; Walesiak, Katarzyna; Krawczak, Karolina; Cabaj, Dominika; Górecki, Andrzej
2014-01-01
Introduction The World Health Organization (WHO) claimed osteoarthritis as a civilization-related disease. The effectiveness of preoperative physiotherapy among patients suffering hip osteoarthritis (OA) at the end of their conservative treatment is rarely described in the literature. The aim of this study was to assess the quality of life and musculoskeletal health status of patients who received preoperative physiotherapy before total hip replacement (THR) surgery within a year prior to admission for a scheduled THR and those who did not. Material and methods Forty-five patients, admitted to the Department of Orthopaedics and Traumatology of Locomotor System for elective total hip replacement surgery, were recruited for this study. The assessment consisted of a detailed interview using various questionnaires: the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the 36-Item Short Form Health Survey (SF-36), and the Hip disability and Osteoarthritis Outcome Score (HOOS), as well as physical examination. Patients were assigned to groups based on their attendance of preoperative physiotherapy within a year prior to surgery. Results Among patients who received preoperative physiotherapy a significant improvement was found for pain, daily functioning, vitality, psychological health, social life, and (active and passive) internal rotation (p < 0.05). Conclusions Patients are not routinely referred to physiotherapy within a year before total hip replacement surgery. This study confirmed that pre-operative physiotherapy may have a positive influence on selected musculoskeletal system status indicators and quality of life in hip osteoarthritis patients awaiting surgery. PMID:25395951
Fukushima, Kensuke; Takahira, Naonobu; Imai, Sousuke; Yamazaki, Tetsuya; Kenmoku, Tomonori; Uchiyama, Katsufumi; Takaso, Masashi
2016-11-01
Femoroacetabular impingement (FAI) is a known patho-mechanism that causes hip pain and osteoarthritis (OA) and is considered uncommon in Japan, while secondary OA due to hip dysplasia is considered common. However, no studies have specifically targeted athletes in Japan and/or Asia. This study aimed to determine FAI prevalence using radiological findings among baseball players playing on a professional, Japanese team. We retrospectively assessed 63 plain anteroposterior (AP) hip radiographs (126 hips from 47 [74.6%] Asian players and 16 [25.3%] non-Asian players) obtained for medical evaluations. Radiographs were used to measure lateral center-edge (LCE) angle; acetabular roof obliquity (ARO); and the presence of crossover sign (COS), posterior wall sign (PWS), coxa profunda, pistol grip deformity, herniation pits, and labral ossification. Further, the prevalence of radiographic indicators related to FAI was compared between Asian and non-Asian players. In the 126 hips examined, 10 hips (7.94%) were classified as having hip dysplasia (LCE angles < 20°). Of the remaining 116 hips, eight (6.9%) had LCE angles > 40°, and 24 hips (20.7%) had AROs of <0°, indicating acetabular over-coverage. In Asian players, COS was identified in 47 hips (54.0%), positive PWS in 38 hips (43.7%), positive coxa profunda in 8 hips (9.2%), and pistol grip deformity in 37 hips (42.5%). Further, herniation pits and positive labral ossification were identified in 25 (28.7%) and 11 (12.6%) hips, respectively. A comparative review of COS prevalence (Asians vs. non-Asians) revealed that COS was significantly higher in Asian players. No differences were observed in the mean LCE angle, mean ARO, or other radiographic indicators. Radiological indicators related to FAI were identified in 76.6% (72/94 hips) of the Asian professional baseball players; this prevalence was considerably higher than that reported for general Asian populations. We consider that elite Asian athletes may frequently show morphological deformities related to FAI. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Araújo, Vanessa Lara; Souza, Thales Rezende; Carvalhais, Viviane Otoni do Carmo; Cruz, Aline Castro; Fonseca, Sérgio Teixeira
2017-05-01
Strengthening of the hip and trunk muscles has the potential to change lower limb kinematic patterns, such as excessive hip medial rotation and adduction during weight-bearing tasks. This study aimed to investigate the effect of hip and trunk muscles strengthening on hip muscle performance, hip passive properties, and lower limb kinematics during step-down task in women. Thirty-four young women who demonstrated dynamic knee valgus during step-down were divided into two groups. The experimental group underwent three weekly sessions of strengthening exercises for eight weeks, and the control group continued their usual activities. The following evaluations were carried out: (a) isokinetic maximum concentric and eccentric work of hip lateral rotators, (b) isokinetic hip passive torque of lateral rotation and resting transverse plane position, and (c) three-dimensional kinematics of the lower limb during step-down. The strengthening program increased concentric (P<0.001) and eccentric (P<0.001) work of hip lateral rotators, and changed hip resting position toward lateral rotation (P<0.001). The intervention did not significantly change hip passive torque (P=0.089, main effect). The program reduced hip (P=0.002), thigh (P=0.024) and shank (P=0.005) adduction during step-down task. Hip, thigh and knee kinematics in transverse plane and foot kinematics in frontal plane did not significantly modify after intervention (P≥0.069, main effect). Hip and trunk strengthening reduced lower limb adduction during step-down. The changes in hip maximum work and resting position may have contributed to the observed kinematic effects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Choi, Shin Ae; Kim, Steven J; Chung, Kwang Chul
2006-10-02
Huntingtin interacting protein-1 (Hip1) is known to be associated with the N-terminal domain of huntingtin. Although Hip1 can induce apoptosis, the exact upstream signal transduction pathways have not been clarified yet. In the present study, we examined whether activation of intrinsic and/or extrinsic apoptotic pathways occurs during Hip1-mediated neuronal cell death. Overexpression of Hip1 induced cell death through caspase-3 activation in immortalized hippocampal neuroprogenitor cells. Interestingly, proteolytic processing of Hip1 into partial fragments was observed in response to Hip1 transfection and apoptosis-inducing drugs. Moreover, Hip1 was found to directly bind to and activate caspase-9. This promoted cytosolic release of cytochrome c and apoptosis-inducing factor via mitochondrial membrane perturbation. Furthermore, Hip1 could directly bind to Apaf-1, suggesting that the neurotoxic signals of Hip1 transmit through the intrinsic mitochondrial apoptotic pathways and the formation of apoptosome complex.
[Case report of a patient with ochronosis and arthroplasty of the hip and both knees].
Moslavac, Aleksandra; Moslavac, Sasa; Cop, Renata
2003-01-01
Alkaptonuria is a rare hereditary metabolic disorder characterised by absence of the enzyme homogentisic acid oxidase. As a result of this defect homogentisic acid accumulates and is excreted in the urine. The term ochronosis is used to describe bluish-black pigmentation of connective tissue. Ochronotic arthropathy results from the pigmented deposits in the joints of the appendicular and axial skeleton. Findings simulate those of uncomplicated degenerative joint disease, with effusion, articular space narrowing, and bony sclerosis. Our patient is a 70-year old male with ochronotic arthropathy. He has typical ears and sclera discoloration, and had arthroplasty of knees 7 and 4 years ago, respectively. In year 2002, he had undergone total right hip arthroplasty and has been admitted for rehabilitation 14th postoperative day. Individually designed rehabilitation regimen included kinesitherapy, hydrokinesitherapy, and ambulation training with gradual increase in weight bearing exercises and electro-analgesia of associated low back pain. In course of rehabilitation our patient improved his endurance with satisfying range of motion of right hip (flexion 90 degrees, abduction 40 degrees) and strength of hip and thigh musculature. The patient was able to walk with crutches without limitation. We conclude that joint destruction followed by painful locomotion due to ochronotic arthropathy is best treated by total joint arthroplasty, as described in our patient.
Bernard, J; Beldame, J; Van Driessche, S; Brunel, H; Poirier, T; Guiffault, P; Matsoukis, J; Billuart, F
2017-11-01
Minimally invasive total hip arthroplasty (THA) is presumed to provide functional and clinical benefits, whereas in fact the literature reveals that gait and posturographic parameters following THA do not recover values found in the general population. There is a significant disturbance of postural sway in THA patients, regardless of the surgical approach, although with some differences between approaches compared to controls: the anterior and anterolateral minimally invasive approaches seem to be more disruptive of postural parameters than the posterior approach. Electromyographic (EMG) study of the hip muscles involved in surgery [gluteus maximus (GMax), gluteus medius (GMed), tensor fasciae latae (TFL), and sartorius (S)] could shed light, the relevant literature involves discordant methodologies. We developed a methodology to assess EMG activity during maximal voluntary contraction (MVC) of the GMax, GMed, TFL and sartorius muscles as a reference for normalization. A prospective study aimed to assess whether hip joint positioning and the learning curve on an MVC test affect the EMG signal during a maximal voluntary contraction. Hip positioning and the learning curve on an MVC test affect EMG signal during MVC of GMax, GMed, TFL and S. Thirty young asymptomatic subjects participated in the study. Each performed 8 hip muscle MVCs in various joint positions recorded with surface EMG sensors. Each MVC was performed 3 times in 1 week, with the same schedule every day, controlling for activity levels in the preceding 24h. EMG activity during MVC was expressed as a ratio of EMG activity during unipedal stance. Non-parametric tests were applied. Statistical analysis showed no difference according to hip position for abductors or flexors in assessing EMG signal during MVC over the 3 sessions. Hip abductors showed no difference between abduction in lateral decubitus with hip straight versus hip flexed: GMax (19.8±13.7 vs. 14.5±7.8, P=0.78), GMed (13.4±9.0 vs. 9.9±6.6, P=0.21) and TFL (69.5±61.7 vs. 65.9±51.3, P=0.50). Flexors showed no difference between hip flexion/abduction/lateral rotation performed in supine or sitting position: TFL (70.6±45.9 vs. 61.6±45.8, P=0.22) and S (101.1±67.9 vs. 72.6±44.6, P=0.21). The most effective tests to assess EMG signal during MVC were for the hip abductors: hip abduction performed in lateral decubitus (36.7% for GMax, 76.7% for GMed), and for hip flexors: hip flexion/abduction/lateral rotation performed in supine decubitus (50% for TFL, 76.7% for S). The study hypothesis was not confirmed, since hip joint positioning and the learning curve on an MVC test did not affect EMG signal during MVC of GMax, GMed, TFL and S muscles. Therefore, a single session and one specific test is enough to assess MVC in hip abductors (abduction in lateral decubitus) and flexors (hip flexion/abduction/lateral rotation in supine position). This method could be applied to assess muscle function after THA, and particularly to compare different approaches. III, case-matched study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Park, Eun Young; Hwang, Seung Sik; Kim, Jai Yong; Cho, Soo Hun
2008-05-01
Fluoridation of drinking water is known to decrease dental caries, particularly in children. However, the effects of fluoridated water on bone over several decades are still in controversy. To assess the risk of hip fracture related to water fluoridation, we evaluated the hip fracture-related hospitalizations of the elderly between a fluoridated city and non-fluoridated cities in Korea. Cheongju as a fluoridated area and Chungju, Chuncheon, Suwon, Wonju as non-fluoridated areas were chosen for the study. We established a database of hip fracture hospitalization episode based on the claims data submitted to the Health Insurance Review Agency from January 1995 to December 2002. The hip fracture hospitalization episodes that satisfied the conditions were those that occurred in patients over 65 years old, the injuries had a hip fracture code (ICD-9 820, ICD-10 S72) and the patients were hospitalized for at least 7days. A total of 80,558 cases of hip fracture hospitalization episodes were analyzed. The admission rates for hip fracture increased with the age of the men and women in both a fluoridated city and the non-fluoridated cities (p<0.01). The relative risk of hip fracture increased significantly both for men and women as their age increased. However, any difference in the hip fracture admission rates was not consistently observed between the fluoridated city and the nonfluoridated cities. We cannot conclude that fluoridation of drinking water increases the risk of hip fracture in the elderly.
Domb, Benjamin G; Stake, Christine E; Finch, Nathan A; Cramer, T Luke
2014-10-01
Hip arthroscopy is a minimally invasive surgical technique often performed in athletes who want an expeditious return to sport. To the authors' knowledge, no studies in the literature provide a time frame or criteria for return to sport after hip arthroscopy. The purpose of this study was to develop an aggregate recommendation for return to sport after hip arthroscopy based on data assimilated from high-volume hip arthroscopy centers. Twenty-seven orthopedic surgeons from high-volume hip arthroscopy centers completed a survey regarding return to sport after hip arthroscopy. The questionnaire asked surgeons to give a time frame for return to sport and to choose meaningful criteria that an athlete must meet prior to return to sport. Surgeons were asked to categorize various common sports as high, medium, or low risk with regard to the hip. The aggregate results were used to create standardized recommendations for time, criteria, and risk for return to competitive sports. Regarding time frame for return to sport, 70% of surgeons recommended 12 to 20 weeks. In addressing criteria for return to sport, 85% of surgeons recommended that patients need to be able to reproduce all motions involved in their sport without pain. A majority of surgeons recommended criteria of pain-free running, jumping, lateral agility drills, and single-leg squats. Finally, surgeons categorized sports requiring the most movement and impact of the hip joint (football, basketball, wrestling, and martial arts) as high-risk sports. Sports with less impact on the hip, such as golf, were ranked as low risk. Copyright 2014, SLACK Incorporated.
2012-01-01
Background Studies on leisure time physical activity as risk factor or protective factor for knee or hip osteoarthritis (OA) show divergent results. Longitudinal prospective studies are needed to clarify the association of physical activity with future OA. The aim was to explore in a prospective population-based cohort study the influence of leisure time physical activity on severe knee or hip OA, defined as knee or hip replacement due to OA. Methods Leisure time physical activity was reported by 28320 participants (mean age 58 years (SD 7.6), 60% women) at baseline. An overall leisure time physical activity score, taking both duration and intensity of physical activities into account, was created. The most commonly reported activities were also used for analysis. The incidence of knee or hip replacement due to OA over 11 years was monitored by linkage with the Swedish hospital discharge register. Cox’s proportional hazards model (crude and adjusted for potential confounding factors) was used to assess the incidence of total joint replacement, or osteotomy (knee), in separate analyses of leisure time physical activity. Results There was no significant overall association between leisure time physical activity and risk for knee or hip replacement due to OA over the 11-year observation time. For women only, the adjusted RR (95% CI) for hip replacement was 0.66 (0.48, 0.89) (fourth vs. first quartile), indicating a lower risk of hip replacement in those with the highest compared with the lowest physical activity. The most commonly reported activities were walking, bicycling, using stairs, and gardening. Walking was associated with a lower risk of hip replacement (adjusted RR 0.76 (95% CI 0.61, 0.94), specifically for women (adjusted RR 0.75 (95% CI 0.57, 0.98)). Conclusions In this population-based study of middle-aged men and women, leisure time physical activity showed no consistent overall relationship with incidence of severe knee or hip OA, defined as joint replacement due to OA, over 11 years. For women, higher leisure time physical activity may have a protective role for the incidence of hip replacement. Walking may have a protective role for hip replacement, specifically for women. PMID:22595023
Sadeghi, Omid; Saneei, Parvaneh; Nasiri, Morteza; Larijani, Bagher; Esmaillzadeh, Ahmad
2017-09-01
Data on the association between general obesity and hip fracture were summarized in a 2013 meta-analysis; however, to our knowledge, no study has examined the association between abdominal obesity and the risk of hip fracture. The present systematic review and meta-analysis of prospective studies was undertaken to summarize the association between abdominal obesity and the risk of hip fracture. We searched online databases for relevant publications up to February 2017, using relevant keywords. In total, 14 studies were included in the systematic review and 9 studies, with a total sample size of 295,674 individuals (129,964 men and 165,703 women), were included in the meta-analysis. Participants were apparently healthy and aged ≥40 y. We found that abdominal obesity (defined by various waist-hip ratios) was positively associated with the risk of hip fracture (combined RR: 1.24, 95% CI: 1.05, 1.46, P = 0.01). Combining 8 effect sizes from 6 studies, we noted a marginally significant positive association between abdominal obesity (defined by various waist circumferences) and the risk of hip fracture (combined RR: 1.36; 95% CI: 0.97, 1.89, P = 0.07). This association became significant in a fixed-effects model (combined effect size: 1.40, 95% CI: 1.25, 1.58, P < 0.001). Based on 5 effect sizes, we found that a 0.1-U increase in the waist-hip ratio was associated with a 16% increase in the risk of hip fracture (combined RR: 1.16, 95% CI: 1.04, 1.29, P = 0.007), whereas a 10-cm increase in waist circumference was not significantly associated with a higher risk of hip fracture (combined RR: 1.13, 95% CI: 0.94, 1.36, P = 0.19). This association became significant, however, when we applied a fixed-effects model (combined effect size: 1.21, 95% CI: 1.15, 1.27, P < 0.001). We found that abdominal obesity was associated with a higher risk of hip fracture in 295,674 individuals. Further studies are needed to test whether there are associations between abdominal obesity and fractures at other bone sites. © 2017 American Society for Nutrition.
Hernigou, Philippe; Dubory, Arnaud; Homma, Yasuhiro; Guissou, Isaac; Flouzat Lachaniette, Charles Henri; Chevallier, Nathalie; Rouard, Hélène
2018-05-09
Symptomatic osteonecrosis related to corticosteroids has a high risk of progression to collapse in absence of treatment. The purposes of this study were to evaluate the results of autologous bone marrow grafting of the symptomatic hip in adult patients with osteonecrosis and to compare the results with core decompression alone in the contralateral symptomatic hip. A total of 125 consecutive patients (78 males and 47 females) with bilateral osteonecrosis (ON) and who had both hips symptomatic and at the same stage on each side (stage I or II) were included in this study from 1988 to 1998. The volume of osteonecrosis was measured with MRI in both hips; the smaller size ON was treated with core decompression, and the contralateral hip with the larger ON was treated with percutaneous mesenchymal cell (MSC) injection obtained from bone marrow concentration. The average total number of MSCs (counted as number of colony forming units-fibroblast) injected in each hip was 90,000 ± 25,000 cells (range 45,000 to 180,000 cells). At the most recent FU (average 25 years after the first surgery, range 20 to 30 years), among the 250 hips included in the study, 35 hips (28%) had collapsed at the most recent follow-up after bone marrow grafting, and 90 (72%) after core decompression (CD). Ninety-five hips (76%) in the CD group underwent total hip replacement and 30 hips (24%) in the bone marrow graft group (p < 0.0001). Hips undergoing only CD were approximately three times more likely to undergo a primary THA (odds ratio: 10.0278; 95% CI: 5.6117 to 17.9190; p < 0.0001) as compared with hips undergoing an initial bone marrow grafting. For the 90 hips treated with bone marrow injection and without collapse, the mean volume of repair evaluated by MRI at the most recent follow-up was 16.4 cm 3 (range 12 to 21 cm 3 ) corresponding to a decrease of the pre-operative average volume from 22.4 cm 3 (range 35-15 cm 3 ) to 6 cm 3 (range 12-0 cm 3 ); as percentage of the volume of the femoral head, the decrease moved from 44.8 to 12%. Core decompression with bone marrow injection improved the outcome of the disease as compared with core decompression alone in the same patient.
Variability of ischiofemoral space dimensions with changes in hip flexion: an MRI study.
Johnson, Adam C; Hollman, John H; Howe, Benjamin M; Finnoff, Jonathan T
2017-01-01
The primary aim of this study was to determine if ischiofemoral space (IFS) dimensions vary with changes in hip flexion as a result of placing a bolster behind the knees during magnetic resonance imaging (MRI). A secondary aim was to determine if IFS dimensions vary between supine and prone hip neutral positions. The study employed a prospective design. Sports medicine center within a tertiary care institution. Five male and five female adult subjects (age mean = 29.2, range = 23-35; body mass index [BMI] mean = 23.5, range = 19.5-26.6) were recruited to participate in the study. An axial, T1-weighted MRI sequence of the pelvis was obtained of each subject in a supine position with their hips in neutral and flexed positions, and in a prone position with their hips in neutral position. Supine hip flexion was induced by placing a standard, 9-cm-diameter MRI knee bolster under the subject's knees. The order of image acquisition (supine hip neutral, supine hip flexed, prone hip neutral) was randomized. The IFS dimensions were then measured on a separate workstation. The investigator performing the IFS measurements was blinded to the subject position for each image. The main outcome measurements were the IFS dimensions acquired with MRI. The mean IFS dimensions in the prone position were 28.25 mm (SD 5.91 mm, standard error mean 1.32 mm). In the supine hip neutral position, the IFS dimensions were 25.1 (SD 5.6) mm. The mean difference between the two positions of 3.15 (3.6) mm was statistically significant (95 % CI of the difference = 1.4 to 4.8 mm, t 19 = 3.911, p = .001). The mean IFS dimensions in the hip flexed position were 36.9 (SD 5.7) mm. The mean difference between the two supine positions of 11.8 (4.1) mm was statistically significant (95 % CI of the difference = 9.9 to 13.7 mm, t 19 = 12.716, p < .001). Our findings demonstrate that the IFS measurements obtained with MRI are dependent upon patient positioning with respect to hip flexion and supine versus prone positions. This finding has implications when evaluating for ischiofemoral impingement, an entity resulting in hip and/or buttock pain secondary to impingement of the quadratus femoris muscle within a pathologically narrowed IFS. One will need to account for patient hip flexion and supine versus prone positioning when evaluating individuals with suspected ischiofemoral impingement.
Zelik, Karl E; Takahashi, Kota Z; Sawicki, Gregory S
2015-03-01
Measuring biomechanical work performed by humans and other animals is critical for understanding muscle-tendon function, joint-specific contributions and energy-saving mechanisms during locomotion. Inverse dynamics is often employed to estimate joint-level contributions, and deformable body estimates can be used to study work performed by the foot. We recently discovered that these commonly used experimental estimates fail to explain whole-body energy changes observed during human walking. By re-analyzing previously published data, we found that about 25% (8 J) of total positive energy changes of/about the body's center-of-mass and >30% of the energy changes during the Push-off phase of walking were not explained by conventional joint- and segment-level work estimates, exposing a gap in our fundamental understanding of work production during gait. Here, we present a novel Energy-Accounting analysis that integrates various empirical measures of work and energy to elucidate the source of unexplained biomechanical work. We discovered that by extending conventional 3 degree-of-freedom (DOF) inverse dynamics (estimating rotational work about joints) to 6DOF (rotational and translational) analysis of the hip, knee, ankle and foot, we could fully explain the missing positive work. This revealed that Push-off work performed about the hip may be >50% greater than conventionally estimated (9.3 versus 6.0 J, P=0.0002, at 1.4 m s(-1)). Our findings demonstrate that 6DOF analysis (of hip-knee-ankle-foot) better captures energy changes of the body than more conventional 3DOF estimates. These findings refine our fundamental understanding of how work is distributed within the body, which has implications for assistive technology, biomechanical simulations and potentially clinical treatment. © 2015. Published by The Company of Biologists Ltd.
Weber, Alexander E; Kuhns, Benjamin D; Cvetanovich, Gregory L; Lewis, Paul B; Mather, Richard C; Salata, Michael J; Nho, Shane J
2017-01-01
The purpose of this study was to examine the hip capsule in a subset of symptomatic patients who underwent capsular closure during hip arthroscopy. All patients undergoing primary hip arthroscopy for femoroacetabular impingement (FAI) with routine capsular closure between January 1, 2012, and December 31, 2015, were eligible. Only patients with unilateral surgery and a postoperative magnetic resonance imaging (MRI; ordered for persistent symptoms) were included. Four independent reviewers evaluated each hip capsule for thickness and the absence or presence of defects. During the study, 1,463 patients had hip arthroscopy for FAI with routine capsular closure, and 53 (3.6%) underwent a postoperative MRI. Fourteen of the 53 were excluded owing to revision status or additional procedures. The final study population included 39 patients (23 female patients and 16 male patients), with an average patient age of 31.7 ± 11.4 years and an average body mass index of 23.3 ± 2.9. There were 3 (7.5%) capsular defects, and the intraclass correlation coefficient (ICC) was 0.82. The operative hip capsule was significantly thicker in the zone of capsulotomy, and subsequent repair as compared with the unaffected, contralateral hip capsule (5.0 ± 1.2 mm vs 4.6 ± 1.4 mm; P = .02), ICC 0.83. Additionally, males had thicker hip capsules as compared with their female counterparts, on the operative side (5.4 ± 1.1 mm vs 4.5 ± 1.2 mm; P = .02) and the nonoperative side (4.8 ± 1.6 mm vs 4.1 ± 0.9 mm; P = .08). In a subset of symptomatic patients after hip arthroscopy for FAI, the majority (92.5%) of the repaired hip capsules remained closed at greater than 1 year of follow-up. The hip capsule adjacent to the capsulotomy and subsequent repair is thickened compared with the same location on the contralateral, nonoperative hip. Aside from gender, patient-related and FAI-related factors do not correlate with capsular thickness nor do they seem to correlate with the propensity to develop a capsular defect. Level IV, prognostic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults
Dudani, Baldev; Shyam, Ashok K; Arora, Pankush; Veigus, Arjun
2015-01-01
Background: Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. Materials and Methods: The current study retrospectively evaluated patients’records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. Results: The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. Conclusion: Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage. PMID:26015634
YouTube provides irrelevant information for the diagnosis and treatment of hip arthritis.
Koller, Ulrich; Waldstein, Wenzel; Schatz, Klaus-Dieter; Windhager, Reinhard
2016-10-01
YouTube is increasingly becoming a key source for people to satisfy the need for additional information concerning their medical condition. This study analyses the completeness of accurate information found on YouTube pertaining to hip arthritis. The present study analyzed 133 YouTube videos using the search terms: hip arthritis, hip arthritis symptoms, hip arthritis diagnosis, hip arthritis treatment and hip replacement. Two quality assessment checklists with a scale of 0 to 12 points were developed to evaluate available video content for the diagnosis and the treatment of hip arthritis. Videos were grouped into poor quality (grade 0-3), moderate quality (grade 4-7) and excellent quality (grade 8-12), respectively. Three independent observers assessed all videos using the new grading system and independently scored all videos. Discrepancies regarding the categories were clarified by consensus discussion. For intra-observer reliabilities, grading was performed at two occasions separated by four weeks. Eighty-four percent (n = 112) had a poor diagnostic information quality, 14% (n = 19) a moderate quality and only 2% (n = 2) an excellent quality, respectively. In 86% (n = 114), videos provided poor treatment information quality. Eleven percent (n = 15) of videos had a moderate quality and only 3% (n = 4) an excellent quality, respectively. The present study demonstrates that YouTube is a poor source for accurate information pertaining to the diagnosis and treatment of hip arthritis. These finding are of high relevance for clinicians as videos are going to become the primary source of information for patients. Therefore, high quality educational videos are needed to further guide patients on the way from the diagnosis of hip arthritis to its proper treatment.
Hafiz, Eliza; Hiller, Claire E; Nicholson, Leslie L; Nightingale, Elizabeth J; Grimaldi, Alison; Refshauge, Kathryn M
2016-03-01
Low range femoral torsion, termed "lateral shaft torsion," has been associated with greater range of hip external rotation and turnout in dancers. It is also hypothesized that achieving greater turnout at the hip minimizes torsion at the knee, shank, ankle, and foot, and consequently reduces incidence of lower limb injuries. The primary aims of this study were to investigate: 1. differences in range of femoral shaft torsion between dancers with and without lower limb injuries; and 2. the relationship between femoral shaft torsion, hip external rotation range, and turnout. A secondary aim was to examine the relationship between femoral shaft torsion and other hip measures: hip strength, lower limb joint hypermobility, hip stability, and foot progression angle, as explanatory variables. Demographic, dance, and injury data were collected, along with physical measures of femoral shaft torsion, hip rotation range of motion, and turnout. Hip strength, control, lower limb hypermobility, and foot progression angle were also measured. Eighty female dancers, 50 with lower limb injury (20.7 ± 4.8 years of age) and 30 without lower limb injury (17.8 ± 4.1 years of age), participated in the study. There was no difference in range of femoral shaft torsion between the groups (p = 0.941). Femoral shaft torsion was weakly correlated with range of hip external rotation (r = -0.034, p = 0.384) and turnout (r = -0.066, p = 0.558). Injured dancers had a significantly longer training history than non-injured dancers (p = 0.001). It was concluded that femoral shaft torsion does not appear to be associated with the overall incidence of lower limb injury in dancers or to be a primary factor influencing extent of turnout in this population.
Risk of Hip Fracture in Benzodiazepine Users With and Without Alzheimer Disease.
Saarelainen, Laura; Tolppanen, Anna-Maija; Koponen, Marjaana; Tanskanen, Antti; Sund, Reijo; Tiihonen, Jari; Hartikainen, Sirpa; Taipale, Heidi
2017-01-01
To investigate the association between benzodiazepine and related drug (BZDR) use and hip fracture as well as postfracture mortality and duration of hospital stay in community-dwellers with and without Alzheimer disease (AD). Retrospective cohort study. The register-based Medication Use and Alzheimer's disease (MEDALZ) study, including all community-dwelling persons diagnosed with AD in Finland during 2005-2011 (n = 70,718) and their matched comparison persons without AD. Persons without BZDR use during the year preceding the AD diagnosis or the corresponding matching date as well as persons without history of hip fracture were included in this study. We investigated the risk of hip fracture associated with BZDR use compared with nonuse separately in persons with and without AD. Further, we investigated the association between BZDR use during hip fracture and 1-year mortality as well as longer than a 4-month hospital stay after hip fracture. Associations were reported as hazard ratios and odds ratios with 95% confidence intervals (CI). BZDR use was associated with an increased risk of hip fracture in persons with and without AD (adjusted hazard ratio 1.4 [95% CI 1.2-1.7] and 1.6 [95% CI 1.3-1.9], respectively). BZDR use during hip fracture was associated with longer than 4-month postfracture hospital stay in persons with AD [adjusted odds ratio 1.9 (95% CI 1.3-2.8)] but not in comparison persons. One-year mortality was not associated with BZDR use during hip fracture. Higher threshold in prescribing BZDRs for neuropsychiatric symptoms might decrease the hip fracture rate and affect the length of hospital stay in persons with AD. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Evaluation of hip fracture risk factors in older adults in the Lebanese population.
Bawab, Wafa; Saad, Mohamad; Hajjar, Nour; Rachidi, Samar; Al Hajje, Amal; Awada, Sanaa; Salameh, Pascale
2014-01-01
Hip fractures are serious fall injuries that often result in long-term functional impairment and increased mortality. As the population ages, the number of hip fractures is likely to increase worldwide. The main objective of this pilot study was to evaluate the risk factors of hip fracture among the older adults in the Lebanese population. This pilot epidemiological, prospective, and case-control study was performed in 6 hospitals in Great Beirut and South Lebanon. Subjects who met the inclusion criteria filled out a questionnaire consisting on the socio- demographic characteristics, health status, drugs intake and cigarette smoking. Overall, 195 subjects were recruited, with 65 cases of hip fracture and 130 controls all aged over 50 yr. Females represented around two third of the studied population. The logistic regression, using adjusted odds ratio (ORa), showed a significant relationship between hip fracture and chronic diseases (ORa=3.02; 95% CI: 1.63, 6.66), antihypertensive drugs intake (ORa=2.72; 95% CI: 1.56, 6.42), fall (ORa=2.79; 95% CI: 1.82, 7.06) previous fracture (ORa=3.80; 95% CI: 1.57, 9.23) and family history of fracture (ORa=4.82; 95% CI: (2.29, 10.86). Besides, smoking increased the risk of hip fracture (ORa=2.55; 95% CI: (1.96, 5.80). Having a bow was associated with the highest risk for hip fracture (ORa=5.18; 95% CI: 2.30, 12.24). Elderly people in Lebanon are exposed to many risk factors contributing to hip fracture. Our finding has implication in geriatric health improvement by preventing hip fracture in the Lebanese population.
2016-08-03
Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis
MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip
Marupaka, Sravan Kumar; Alluri, Swathi; MD, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran
2015-01-01
Introduction Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. Aim To study pre and post core decompression MRI changes in avascular necrosis of hip. Materials and Methods This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Results Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Conclusion Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip. PMID:26816966
Knapik, Derrick M.; Sheehan, Joe; Nho, Shane J.; Voos, James E.; Salata, Michael J.
2018-01-01
Background: Intra-articular injuries to the hip in elite athletes represent a source of significant pain and disability. Hip arthroscopic surgery has become the gold standard for the treatment of disorders involving the hip joint. Purpose: To examine the incidence of and abnormalities treated with hip arthroscopic surgery as well as the impact on future participation in American football athletes invited to the National Football League (NFL) Scouting Combine with a history of hip arthroscopic surgery. Study Design: Cohort study; Level of evidence, 3. Methods: Athletes invited to the NFL Combine from 2012 to 2015 were evaluated for a history of hip arthroscopic surgery. Athlete demographics, imaging findings, and physical examination results were gathered using the NFL Combine database. Information on prospective participation in the NFL with regard to draft status, games played, games started, and current status was gathered using publicly available databases and compared against all other athletes participating in the combine. Results: Fourteen athletes (15 hips) had a history of arthroscopic hip surgery. Acetabular labral tears were treated in 93% (14 hips), with femoroacetabular impingement decompression performed in 33% (5 hips). Compared with athletes who had no history of hip arthroscopic surgery, those undergoing arthroscopic surgery did not possess a lower likelihood of being drafted (66% vs 71%, respectively; P = .78) or of being on an active roster (52% vs 43%, respectively; P = .44) after their first season in the NFL. Moreover, there was no significant difference in the number of regular-season games played (10.9 ± 4.8 with arthroscopic surgery vs 11.0 ± 5.1 without; P = .96) or started (7.0 ± 3.6 with arthroscopic surgery vs 7.1 ± 5.3 without; P = .98). Conclusion: American football athletes invited to the NFL Combine with a history of hip arthroscopic surgery were not at risk for diminished participation when compared with all other athletes during their first season in the NFL. PMID:29435469
Are Hip-Specific Items Useful in a Quality of Life Questionnaire for Patients with Hip Fractures?
ERIC Educational Resources Information Center
Yao, Kai-Ping Grace; Lee, Hsin-Yi; Tsauo, Jau-Yih
2009-01-01
Researchers measure the significance of hip fracture by the patient's impairment. The patient's quality of life (QOL) is usually also substantially affected. However, there is no specific quality of life (QOL) questionnaire for patients with hip fractures. This study was designed to determine whether adding a new set of specific questions about…
Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty
Wu, Guo-Liang; Zhu, Wei; Zhao, Yan; Ma, Qi; Weng, Xi-Sheng
2016-01-01
Objective: The present study aimed to review the characteristics and influencing factors of squeaking after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and to analyze the possible mechanisms of the audible noise. Data Sources: The data analyzed in this review were based on articles from PubMed and Web of Science. Study Selection: The articles selected for review were original articles and reviews found based on the following search terms: “total hip arthroplasty”, “ceramic-on-ceramic”, “hip squeaking”, and “hip noise.” Results: The mechanism of the squeaking remains unknown. The possible explanations included stripe wear, edge loading, a third body, fracture of the ceramic liner, and resonance of the prosthesis components. Squeaking occurrence is influenced by patient, surgical, and implant factors. Conclusions: Most studies indicated that squeaking after CoC THA was the consequence of increasing wear or impingement, caused by prosthesis design, patient characteristics, or surgical factors. However, as conflicts exist among different articles, the major reasons for the squeaking remain to be identified. PMID:27453238
Pandit, R
1996-08-01
Primary bipolar femoral head arthroplasties performed on 100 osteoarthritic hips were studied to a minimum of 5 years after surgery. All arthroplasties were performed on physically active patients. At a mean follow-up period of 5.5 years, The Hospital for Special Surgery hip scores were good to excellent in 96 hips. Transient startup soreness constituted the most frequent complaint, occurring in 34 hips. Three hips had more persistent pain localized to the acetabulum, necessitating revision to fixed sockets, which alleviated the symptoms. Four additional hips, in heavy, active men, developed polyethylene fatigue fracture and component disassembly. Acetabular migration of more than 5 mm developed in one hip. Motion, as determined radiologically, occurred primarily at the inner bearing. There were no dislocations or infections in the series. The Bateman bipolar prosthesis provides generally good results in osteoarthritic hips. The shorter operating time and the case of revision are special advantages of bipolar devices. Start-up soreness and stiffness is a shortcoming in approximately one third of cases. Component disassembly in heavy, active men is a problem and the bipolar arthroplasty should be avoided in these patients. Start-up soreness was a significant problem in particular.
Trends in hip fracture-related mortality in Texas, 1990-2007.
Orces, Carlos H; Alamgir, Abul H
2011-07-01
There are limited data about trends in hip fracture-related mortality. In this study, we examined temporal trends in hip fracture mortality rates among persons aged 50 years or older in Texas between 1990 and 2007. Hip fracture-related mortality was defined as a death on the multiple cause of death record for which hip fracture was listed as a contributing cause. Population estimates for Texas were used as the denominator to calculate mortality rates per 100,000 persons. The joinpoint regression analysis was used to identify points where a statistically significant change occurred in the linear slope of the rates. A total of 14,350 death certificates listed hip fracture as a contributing cause of death. Hip fracture rates decreased predominantly among men by 0.8% (95% CI, -1.5 to -0.1) per year. Conversely, age-adjusted rates among women increased by 0.3% (95% CI, -0.4 to 1.0) per year. By race/ethnicity, hip fracture mortality rates increased annually 2.2% (95% CI, -0.1 to 4.4) among blacks, whereas the rates among whites and Hispanics remained steady. Moreover, the proportion of death records that listed nursing homes and residence as a place of death increased by 2.2% (95% CI, 1.6 to 2.9) and 8.7% (95% CI, 6.3 to 11.0) per year, respectively. Hip fracture mortality rates decreased predominantly among men in Texas during the study period. Increasing hip fracture mortality rates among blacks and nursing home residents merit further research.
Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar
2017-01-01
Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.
Fink, Howard A.; Harrison, Stephanie L.; Taylor, Brent C.; Cummings, Steven R.; Schousboe, John T.; Kuskowski, Michael A.; Stone, Katie L.; Ensrud, Kristine E.
2009-01-01
To examine the fracture pattern in older women whose bone mineral density (BMD) T-score criteria for osteoporosis at hip and spine disagree, hip and spine BMD were measured in Study of Osteoporotic Fractures participants using dual energy x-ray absorptiometry (DXA). Hip osteoporosis was defined as T-score ≤-2.5 at femoral neck or total hip, and spine osteoporosis as T-score ≤-2.5 at lumbar spine. Incident clinical fractures were self-reported and centrally adjudicated. Incident radiographic spine fractures were defined morphometrically. Compared to women with osteoporosis at neither hip nor spine, those osteoporotic only at hip had a 3.0-fold age and weight-adjusted increased risk for hip fracture (95%CI 2.4-3.6), and smaller increases in risk of nonhip nonspine (HR=1.6), clinical spine (OR=2.2), and radiographic spine fractures (OR=1.5). Women osteoporotic only at spine had a 2.8-fold increased odds of radiographic spine fracture (95%CI 2.1-3.8), and smaller increases in risk of clinical spine (OR=1.4), nonhip nonspine (HR=1.6), and hip fractures (HR=1.2). Discordant BMD results predict different fracture patterns. DXA fracture risk estimation in these patients should be site-specific. Women osteoporotic only at spine would not have been identified from hip BMD measurement alone, and may have a sufficiently high fracture risk to warrant preventive treatment. PMID:18296090
Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar
2017-01-01
Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148
Traumatic hip dislocation at a regional trauma centre in Nigeria.
Onyemaechi, N O C; Eyichukwu, G O
2011-01-01
Traumatic dislocation or fracture-dislocation of the hip is an orthopaedic emergency that is steadily increasing in incidence due to high-speed motor vehicular accidents. These injuries need to be recognized early and promptly treated to prevent morbidity and long-term complications. Some of the fundamental issues in the management of traumatic dislocations of the hip are the critical interval between injury and reduction, the type of reduction most suitable for various types of injury and the duration of immobilization that give the best results. This study was carried out at the National Orthopaedic Hospital Enugu, a regional trauma and orthopaedic centre in South-East Nigeria. The purpose of the study is to describe the pattern of presentation and to identify the factors that determine the long-term outcome in the treatment of traumatic dislocations and fracture-dislocations of the hip at Enugu, Nigeria. The case notes of all the patients that presented with traumatic dislocations and fracture-dislocations of the hip between January 2003 and December 2007 were reviewed. The information extracted and analyzed included the patients' demographics, etiology of injury, time interval before reduction, associated injuries, treatment offered, complications and follow-up. Thompson-Epstein classification was used to grade the posterior hip dislocations. The outcome of treatment was evaluated using the clinical and radiological criteria proposed by Epstein (1974). Three patients with incomplete data and two patients with central fracture dislocation were excluded from this study. Forty-eight patients with 50 hip dislocations were analyzed. The age range was 12 years to 67 years with a mean age of 34.8 years. Thirty-nine patients (81.3%) were males and 9 (18.7%) were females. Road-traffic accident was the leading cause of traumatic hip dislocation in this series, 44 cases (91.6%). Posterior dislocation occurred in 48 hips (96%) while anterior dislocation occurred in 2 hips (4%). Forty-seven hips (94%) were treated by primary closed reduction, two hips (4%) were treated with open reduction and one patient (2%) had Girdlestone excision arthroplasty. Thirty-six hips (73.5%) were reduced with 12 hours of the injury. Concomitant injuries were found in 37 patients (77%). The follow up period ranged from 10 months to 36 months with a mean follow up period of 15 months. Post-traumatic osteoarthritis occurred in 2 hips (4%) avascular necrosis of the femoral head was seen in 2 hips (4%). Five patients had sciatic nerve paresis while there was recurrence in one hip. No mortality was recorded. Traumatic dislocations and fracture-dislocations of the hip are severe injuries caused mostly by high-speed motor-vehicular accidents. Young adult males are most commonly affected, and there is a high rate of concomitant injuries. Excellent results can be achieved by early and stable closed reduction of these injuries with immobilization of the affected hips.
2011-01-01
Background There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Methods Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. Results There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. Conclusion A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted. PMID:21235820
Wang, Yuanyuan; Simpson, Julie Anne; Wluka, Anita E; English, Dallas R; Giles, Graham G; Graves, Stephen; Cicuttini, Flavia M
2011-01-16
There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted.
Hip Biomechanics Are Altered in Male Runners with Achilles Tendinopathy.
Creaby, Mark W; Honeywill, Conor; Franettovich Smith, Melinda M; Schache, Anthony G; Crossley, Kay M
2017-03-01
Achilles tendinopathy (AT) is a prevalent injury in running sports. Understanding the biomechanical factors associated with AT will assist in its management and prevention. The purpose of this study was to compare hip and ankle kinematics and kinetics in runners with and without AT. Fourteen male runners with AT and 11 healthy male runners (CTRL) ran over ground while lower-limb joint motion and ground reaction force data were synchronously captured. Hip and ankle joint angles, moments, and impulses in all three planes (sagittal, transverse, and frontal) were extracted for analysis. Independent t-tests were used to compare the differences between the AT and the CTRL groups for the biomechanical variables of interest. After Bonferroni adjustment, an alpha level of 0.0026 was set for all analyses. The AT group exhibited an increased peak hip external rotation moment (P = 0.001), hip external rotation impulse (P < 0.001), and hip adduction impulse (P < 0.001) compared with the CTRL group. No significant differences in ankle biomechanics were observed. This study presents preliminary evidence indicating that male runners with AT display altered hip biomechanics with respect to their healthy counterparts. Because of the retrospective design of the study, it is unknown whether these alterations are a predisposing factor for the disorder, a result of the condition, or a combination of both. The results of this study suggest that optimizing hip joint function should be considered in the rehabilitation of runners with AT.
Umehara, Jun; Ikezoe, Tome; Nishishita, Satoru; Nakamura, Masatoshi; Umegaki, Hiroki; Kobayashi, Takuya; Fujita, Kosuke; Ichihashi, Noriaki
2015-12-01
Decreased flexibility of the tensor fasciae latae is one factor that causes iliotibial band syndrome. Stretching has been used to improve flexibility or tightness of the muscle. However, no studies have investigated the effective stretching position for the tensor fasciae latae using an index to quantify muscle elongation in vivo. The aim of this study was to investigate the effects of hip rotation and knee angle on tensor fasciae latae elongation during stretching in vivo using ultrasonic shear wave elastography. Twenty healthy men participated in this study. The shear elastic modulus of the tensor fasciae latae was calculated using ultrasonic shear wave elastography. Stretching was performed at maximal hip adduction and maximal hip extension in 12 different positions with three hip rotation conditions (neutral, internal, and external rotations) and four knee angles (0°, 45°, 90°, and 135°). Two-way analysis of variance showed a significant main effect for knee angle, but not for hip rotation. The post-hoc test for knee angle indicated that the shear elastic modulus at 90° and 135° were significantly greater than those at 0° and 45°. Our results suggest that adding hip rotation to the stretching position with hip adduction and extension may have less effect on tensor fasciae latae elongation, and that stretching at >90° of knee flexion may effectively elongate the tensor fasciae latae. Copyright © 2015 Elsevier Ltd. All rights reserved.
Birn, Ida; Mechlenburg, Inger; Liljensøe, Anette; Soballe, Kjeld; Larsen, Jens Fromholt
2016-05-01
Weight loss after bariatric surgery is shown to reduce knee and hip pain in the majority of the severely obese. Studies indicate that with a reduction in musculoskeletal symptoms, quality of life (QoL) will improve. The group of severely obese with knee and hip symptoms might therefore have potential for a large improvement in QoL after a bariatric surgery. This study aimed therefore to assess the association between the degree of knee and hip symptoms before a laparoscopic Roux-en-Y gastric bypass (LRYGB) and the improvement of QoL, 1 year after the surgery, in severely obese. This study is a historical cohort study based on data collected consecutively at the private hospital Mølholm, Denmark. Before LRYGB surgery, 4548 severely obese completed a questionnaire on knee and hip symptoms of obesity and QoL. One year after surgery, 2862 (62.9 %) of the participants answered the same questionnaire again. Participants with moderate or severe knee or hip symptoms, before the surgery, experienced a statistically significantly larger improvement of their QoL, compared to participants without symptoms before the surgery. Furthermore, an association between the reduction of knee and hip symptoms and the improvement in QoL was found. Severely obese with moderate or severe preoperative knee and hip symptoms experienced a larger improvement of their QoL after a LRYGB compared to participants without symptoms before the operation.
NASA Astrophysics Data System (ADS)
Jodda, Agata; Urbański, Bartosz; Piotrowski, Tomasz; Malicki, Julian
2016-03-01
Background: The paper shows the methodology of an in-phantom study of the protection level of the bone marrow in patients with cervical or endometrial cancer for three radiotherapy techniques: three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and volumetric modulated arc therapy, preceded by the procedures of image guidance. Methods/Design: The dosimetric evaluation of the doses will be performed in an in-house multi-element anthropomorphic phantom of the female pelvic area created by three-dimensional printing technology. The volume and position of the structures will be regulated according to the guidelines from the Bayesian network. The input data for the learning procedure of the model will be obtained from the retrospective analysis of imaging data obtained for 96 patients with endometrial cancer or cervical cancer treated with radiotherapy in our centre in 2008-2013. Three anatomical representations of the phantom simulating three independent clinical cases will be chosen. Five alternative treatment plans (1 × three-dimensional conformal radiotherapy, 2 × intensity modulated radiotherapy and 2 × volumetric modulated arc therapy) will be created for each representation. To simulate image-guided radiotherapy, ten specific recombinations will be designated, for each anatomical representation separately, reflecting possible changes in the volume and position of the phantom components. Discussion: The comparative analysis of planned measurements will identify discrepancies between calculated doses and doses that were measured in the phantom. Finally, differences between the doses cumulated in the hip plates performed by different techniques simulating the gynaecological patients' irradiation of dose delivery will be established. The results of this study will form the basis of the prospective clinical trial that will be designed for the assessment of hematologic toxicity and its correlation with the doses cumulated in the hip plates, for gynaecologic patients undergoing radiation therapy.
Validation of a 3D CT method for measurement of linear wear of acetabular cups
2011-01-01
Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy. PMID:21281259
The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.
Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A
2016-03-01
To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P < .001). Only 3 (7%) of these 41 patients failed and were converted to a total hip replacement (THR); however, patients who did not have an established diagnosis (n = 27) before undergoing hip arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P < .05) of patients with hip pain caused by severe metal synovial reaction or metal-on-metal reaction were women. A total of 5 (7%) patients had minor-to-mild complications after hip arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing arthroplasty. Having an accurate diagnosis before hip arthroscopy improves the likelihood a good outcome. Level IV - therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Use of Organic Nitrates and the Risk of Hip Fracture: A Population-Based Case-Control Study
Pouwels, Sander; Lalmohamed, Arief; van Staa, Tjeerd; Cooper, Cyrus; Souverein, Patrick; Leufkens, Hubertus G.; Rejnmark, Lars; de Boer, Anthonius; Vestergaard, Peter; de Vries, Frank
2010-01-01
Context: Use of organic nitrates has been associated with increased bone mineral density. Moreover, a large Danish case-control study reported a decreased fracture risk. However, the association with duration of nitrate use, dose frequency, and impact of discontinuation has not been extensively studied. Objective: Our objective was to evaluate the association between organic nitrates and hip fracture risk. Methods: A case-control study was conducted using the Dutch PHARMO Record Linkage System (1991–2002, n = 6,763 hip fracture cases and 26,341 controls). Cases had their first admission for hip fracture, whereas controls had not sustained any fracture after enrollment. Current users of organic nitrates were patients who had received a prescription within 90 d before the index date. The analyses were adjusted for disease and drug history. Results: Current use of nitrates was not associated with a decreased risk of hip fracture [adjusted odds ratio (OR) = 0.93; 95% confidence interval (CI) = 0.83–1.04]. Those who used as-needed medication only had a lower risk of hip fracture (adjusted OR = 0.83; 95% CI = 0.63–1.08) compared with users of maintenance medication only (adjusted OR = 1.17; 95% CI = 0.97–1.40). No association was found between duration of nitrate use and fracture risk. Conclusions: Our overall analyses showed that risk of a hip fracture was significantly lower among users of as-needed organic nitrates, when compared with users of maintenance medication. Our analyses of hip fracture risks with duration of use did not further support a beneficial effect of organic nitrates on hip fracture, although residual confounding may have masked beneficial effects. PMID:20130070
Generalized Joint Hypermobility Is Predictive of Hip Capsular Thickness.
Devitt, Brian M; Smith, Bjorn N; Stapf, Robert; Tacey, Mark; O'Donnell, John M
2017-04-01
The pathomechanics of hip microinstability are not clearly defined but are thought to involve anatomical abnormalities, repetitive forces across the hip, and ligamentous laxity. The purpose of this study was to explore the relationship between generalized joint hypermobility (GJH) and hip capsular thickness. The hypothesis was that GJH would be predictive of a thin hip capsule. Cross-sectional study; Level of evidence, 3. A prospective study was performed on 100 consecutive patients undergoing primary hip arthroscopy for the treatment of hip pain. A Beighton test score (BTS) was obtained prior to each procedure. The maximum score was 9, and a score of ≥4 was defined as hypermobile. Capsular thickness at the level of the anterior portal, corresponding to the location of the iliofemoral ligament, was measured arthroscopically using a calibrated probe. The presence of ligamentum teres (LT) pathology was also recorded. Fifty-five women and 45 men were included in the study. The mean age was 32 years (range, 18-45 years). The median hip capsule thickness was statistically greater in men than women (12.5 and 7.5 mm, respectively). The median BTS for men was 1 compared with 4 for women ( P < .001). A statistically significant association was found between BTS and capsular thickness; a BTS of <4 is strongly predictive of having a capsular thickness of ≥10 mm, while a BTS ≥4 correlates with a capsular thickness of <10 mm. There was a statistically greater incidence of LT tears in patients with a capsular thickness of ≤7.5 mm and a BTS of ≥4 ( P < .001). Measurement of the GJH is highly predictive of hip capsular thickness. A BTS of <4 correlates significantly with a capsular thickness of ≥10 mm, while a BTS ≥4 correlates significantly with a thickness of <10 mm.
Use of proton pump inhibitors and mortality after hip fracture in a nationwide study.
Brozek, W; Reichardt, B; Zwerina, J; Dimai, H P; Klaushofer, K; Zwettler, E
2017-05-01
We analyzed the association of proton pump inhibitors (PPIs) with mortality after osteoporosis-related hip fracture in Austria. PPIs were associated with reduced 90-day mortality but elevated mortality after half a year when initiated pre-fracture. Inpatients and discharged patients on PPIs showed lowered in-hospital and 90-day mortality, respectively. We herein investigated use of proton pump inhibitors (PPIs) and mortality among hip fracture patients in a nationwide study in Austria. In this retrospective cohort study, data on use of PPIs were obtained from 31,668 Austrian patients ≥50 years with a hip fracture between July 2008 and December 2010. All-cause mortality in patients without anti-osteoporotic drug treatment who had received their first recorded PPI prescription in the study period either before or after fracture was compared with hip fracture patients on neither PPIs nor anti-osteoporotic medication using logistic and Cox regression analysis. With PPI use, 90-day mortality was significantly reduced, both at initiation before (OR 0.66; p < 0.0001) and after hip fracture (OR 0.23; p < 0.0001). 90-day mortality was also reduced when PPIs were prescribed not until after discharge from the last recorded hip fracture-related hospital stay (OR 0.49; p < 0.0001) except for patients aged <70 years. In a sub-cohort of patients beginning PPIs during hospital stay, in-hospital mortality (0.2%) was substantially reduced relative to matched control patients (3.5%) (p < 0.0001). Longer-term mortality significantly increased after half a year post-fracture only among those who started PPI prescription before fracture. PPI use during and after hospital stay due to hip fracture is associated with a considerable decrease in mortality. These findings could have implications for hip fracture treatment.
Use of organic nitrates and the risk of hip fracture: a population-based case-control study.
Pouwels, Sander; Lalmohamed, Arief; van Staa, Tjeerd; Cooper, Cyrus; Souverein, Patrick; Leufkens, Hubertus G; Rejnmark, Lars; de Boer, Anthonius; Vestergaard, Peter; de Vries, Frank
2010-04-01
Use of organic nitrates has been associated with increased bone mineral density. Moreover, a large Danish case-control study reported a decreased fracture risk. However, the association with duration of nitrate use, dose frequency, and impact of discontinuation has not been extensively studied. Our objective was to evaluate the association between organic nitrates and hip fracture risk. A case-control study was conducted using the Dutch PHARMO Record Linkage System (1991-2002, n = 6,763 hip fracture cases and 26,341 controls). Cases had their first admission for hip fracture, whereas controls had not sustained any fracture after enrollment. Current users of organic nitrates were patients who had received a prescription within 90 d before the index date. The analyses were adjusted for disease and drug history. Current use of nitrates was not associated with a decreased risk of hip fracture [adjusted odds ratio (OR) = 0.93; 95% confidence interval (CI) = 0.83-1.04]. Those who used as-needed medication only had a lower risk of hip fracture (adjusted OR = 0.83; 95% CI = 0.63-1.08) compared with users of maintenance medication only (adjusted OR = 1.17; 95% CI = 0.97-1.40). No association was found between duration of nitrate use and fracture risk. Our overall analyses showed that risk of a hip fracture was significantly lower among users of as-needed organic nitrates, when compared with users of maintenance medication. Our analyses of hip fracture risks with duration of use did not further support a beneficial effect of organic nitrates on hip fracture, although residual confounding may have masked beneficial effects.
Bachmann, Katherine Neubecker; Fazeli, Pouneh K; Lawson, Elizabeth A; Russell, Brian M; Riccio, Ariana D; Meenaghan, Erinne; Gerweck, Anu V; Eddy, Kamryn; Holmes, Tara; Goldstein, Mark; Weigel, Thomas; Ebrahimi, Seda; Mickley, Diane; Gleysteen, Suzanne; Bredella, Miriam A; Klibanski, Anne; Miller, Karen K
2014-12-01
Data suggest that anorexia nervosa (AN) and obesity are complicated by elevated fracture risk, but skeletal site-specific data are lacking. Traditional bone mineral density (BMD) measurements are unsatisfactory at both weight extremes. Hip structural analysis (HSA) uses dual-energy X-ray absorptiometry data to estimate hip geometry and femoral strength. Factor of risk (φ) is the ratio of force applied to the hip from a fall with respect to femoral strength; higher values indicate higher hip fracture risk. The objective of the study was to investigate hip fracture risk in AN and overweight/obese women. This was a cross-sectional study. The study was conducted at a Clinical Research Center. PATIENTS included 368 women (aged 19-45 y): 246 AN, 53 overweight/obese, and 69 lean controls. HSA-derived femoral geometry, peak factor of risk for hip fracture, and factor of risk for hip fracture attenuated by trochanteric soft tissue (φ(attenuated)) were measured. Most HSA-derived parameters were impaired in AN and superior in obese/overweight women vs controls at the narrow neck, intertrochanteric, and femoral shaft (P ≤ .03). The φ(attenuated) was highest in AN and lowest in overweight/obese women (P < .0001). Lean mass was associated with superior, and duration of amenorrhea with inferior, HSA-derived parameters and φ(attenuated) (P < .05). Mean φ(attenuated) (P = .036), but not femoral neck BMD or HSA-estimated geometry, was impaired in women who had experienced fragility fractures. Femoral geometry by HSA, hip BMD, and factor of risk for hip fracture attenuated by soft tissue are impaired in AN and superior in obesity, suggesting higher and lower hip fracture risk, respectively. Only attenuated factor of risk was associated with fragility fracture prevalence, suggesting that variability in soft tissue padding may help explain site-specific fracture risk not captured by BMD.
Liu, Chuan-Chuan; Hung, Chung-Lieh; Shih, Shou-Chuan; Ko, Hung-Ju; Chang, Ray-E
2015-08-20
Health intervention program (HIP) based on diet and lifestyle modifications had been shown to improve cardiovascular risks. The effects of such program on a variety of cardiometabolic outcome measures conducted in a strict analysis remained relatively unexplored. A total of 2,660 participants (mean age: 43.3 ± 10 years, 63.6% male) underwent annual health survey from our health evaluation department. We implemented health intervention program (HIP) in which diet and lifestyle modifications including smoking cessation and advised physical activities were introduced. We further studied the effects of HIP on several cardiometabolic outcome measures including Framingham, metabolic scores and renal function in terms of Egfr with a mean follow-up period of 38.5 months. Propensity score (PS) matching (HIP vs non-HIP group) was used to avoid effects of case selection bias. Totally 1,004 (502 subjects for each group) left after PS matching protocol (both HIP and non-HIP group). The HIP group showed significant decline of waist circumference (-1.46 ± 0.61, p = 0.016), post-prandial glucose (-6.77 ± 2.06, p = 0.001), and total cholesterol level (-4.42 ± 2.15, p = 0.04), with borderline increase in eGFR (1.72 ± 0.94, p = 0.068) after an average of 1.91 ± 1.14 year follow up period. Exercise behavior significantly increased for those who received HIP when compared to the non-HIP group (44.6 vs 52.4 %, p = 0.014). PS matching and difference-in-difference (DID) analysis further confirmed the beneficial effects of ATP III reduction by HIP (-0.36 ± 0.06, p < 0.05). We demonstrated in our study that several cardiometabolic profiles can be substantially improved after health intervention introduction at the health evaluation center, supporting the beneficial evidence of such health intervention programs implementation based on primary prevention view points.
Ioannidis, G.; Flahive, J.; Pickard, L.; Papaioannou, A.; Chapurlat, R. D.; Saag, K. G.; Silverman, S.; Anderson, F. A.; Gehlbach, S. H.; Hooven, F. H.; Boonen, S.; Compston, J. E.; Cooper, C.; Díez-Perez, A.; Greenspan, S. L.; LaCroix, A. Z.; Lindsay, R.; Netelenbos, J. C.; Pfeilschifter, J.; Rossini, M.; Roux, C.; Sambrook, P. N.; Siris, E. S.; Watts, N. B.
2016-01-01
Summary We evaluated healthcare utilization associated with treating different fracture types in over 51,000 women aged ≥55 years. Over the course of 1 year, there were five times more non-hip, non-spine fractures than hip or spine fractures, resulting in twice as many days of hospitalization and rehabilitation/nursing home care for non-hip, non-spine fractures. Purpose To evaluate the medical healthcare utilization associated with treating several types of fractures in women aged 55 years or older from various geographic regions. Methods Information from the Global Longitudinal study of Osteoporosis in Women (GLOW) was collected via self-administered patient questionnaires at baseline and year 1 (n=51,491). Self-reported clinically recognized low-trauma fractures at year 1 were classified as incident spine, hip, wrist/hand, arm/shoulder, pelvis, rib, leg, and other fractures. Healthcare utilization data were self-reported and included whether the fracture was treated at a doctor’s office/clinic or at a hospital. Patients were also asked if they had undergone surgery or been treated at a rehabilitation center or nursing home. Results Over the 1-year study period, there were 195 spine, 134 hip, and 1,654 non-hip, non-spine fractures. In the GLOW cohort, clinical vertebral fractures resulted in 617 days of hospitalization and 512 days of rehabilitation/nursing home care, while hip fractures accounted for 1,306 days of hospitalization and 1,650 days of rehabilitation/nursing home care. Of particular interest is the result that non-hip, non-spine fractures resulted in 3,805 days in hospital and 5,186 days of rehabilitation/nursing home care. Conclusions While hip and vertebral fractures are well recognized for their associated increase in health resource utilization, non-hip, non-spine fractures, by virtue of their 5-fold greater number, require significantly more healthcare resources. PMID:22525976
Gupta, Asheesh; Redmond, John M; Hammarstedt, Jon E; Schwindel, Leslie; Domb, Benjamin G
2014-10-01
The purpose of this systematic review was to evaluate the literature to determine complications of hip arthroscopy, with a secondary focus on how to minimize complications and risks. Two independent reviewers performed a search of PubMed for articles that contained at least 1 of the following terms: complications and hip arthroscopy, hip impingement, femoral acetabular impingement and complications, or femoroacetabular impingement (FAI) and complications. The search was limited to articles published between 1999 and June 2013. An additional search was performed for articles evaluating techniques on how to minimize complications. We identified 81 studies (5,535 patients; 6,277 hips). The mean age was 35.48 years, and the mean body mass index was 25.20 kg/m(2). Of the participants, 52% were male and 48% were female. The majority of studies were Level IV Evidence (63%). A total of 285 complications were reported, for an overall rate of 4.5%. There were 26 major complications (0.41%) and a 4.1% minor complication rate. The overall reoperation rate was 4.03%. A total of 94 hips underwent revision arthroscopy. Regarding open procedures, 150 patients (93%) underwent either total hip arthroplasty or a hip resurfacing procedure. The conversion rate to total hip arthroplasty or a resurfacing procedure was 2.4%. Overall, primary hip arthroscopy is a successful procedure with low rates of major (0.41%) and minor (4.1%) complications. The reoperation rate was 4.03% in our review. There is admittedly a learning curve to performing hip arthroscopy, and we present a systematic review of the complications and how to minimize these complications with careful technique and planning. Level IV, systematic review of Level II to V studies. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
What is the impingement-free range of motion of the asymptomatic hip in young adult males?
Larkin, Brian; van Holsbeeck, Marnix; Koueiter, Denise; Zaltz, Ira
2015-04-01
Femoroacetabular impingement is a recognized cause of chondrolabral injury. Although surgical treatment for impingement seeks to improve range of motion, there are very little normative data on dynamic impingement-free hip range of motion (ROM) in asymptomatic people. Hip ultrasound demonstrates labral anatomy and femoral morphology and, when used dynamically, can assist in measuring range of motion. The purposes of this study were (1) to measure impingement-free hip ROM until labral deflection is observed; and (2) to measure the maximum degree of sagittal plane hip flexion when further flexion is limited by structural femoroacetabular abutment. Forty asymptomatic adult male volunteers (80 hips) between the ages of 21 and 35 years underwent bilateral static and dynamic hip ultrasound examination. Femoral morphology was characterized and midsagittal flexion passive ROM was measured at two points: (1) at the initiation of labral deformation; and (2) at maximum flexion when the femur impinged on the acetabular rim. The mean age of the subjects was 28 ± 3 years and the mean body mass index was 25 ± 4 kg/m(2). Mean impingement-free hip passive flexion measured from full extension to initial labral deflection was 68° ± 17° (95% confidence interval [CI], 65-72). Mean maximum midsagittal passive flexion, measured at the time of bony impingement, was 96° ± 6° (95% CI, 95-98). Using dynamic ultrasound, we found that passive ROM in the asymptomatic hip was much less than the motion reported in previous studies. Measuring ROM using ultrasound is more accurate because it allows anatomic confirmation of terminal hip motion. Surgical procedures used to treat femoroacetabular impingement are designed to restore or increase hip ROM and their results should be evaluated in light of precise normative data. This study suggests that normal passive impingement-free femoroacetabular flexion in the young adult male is approximately 95°.
Bachmann, Katherine Neubecker; Fazeli, Pouneh K.; Lawson, Elizabeth A.; Russell, Brian M.; Riccio, Ariana D.; Meenaghan, Erinne; Gerweck, Anu V.; Eddy, Kamryn; Holmes, Tara; Goldstein, Mark; Weigel, Thomas; Ebrahimi, Seda; Mickley, Diane; Gleysteen, Suzanne; Bredella, Miriam A.; Klibanski, Anne
2014-01-01
Context: Data suggest that anorexia nervosa (AN) and obesity are complicated by elevated fracture risk, but skeletal site-specific data are lacking. Traditional bone mineral density (BMD) measurements are unsatisfactory at both weight extremes. Hip structural analysis (HSA) uses dual-energy X-ray absorptiometry data to estimate hip geometry and femoral strength. Factor of risk (φ) is the ratio of force applied to the hip from a fall with respect to femoral strength; higher values indicate higher hip fracture risk. Objective: The objective of the study was to investigate hip fracture risk in AN and overweight/obese women. Design: This was a cross-sectional study. Setting: The study was conducted at a Clinical Research Center. Patients: Patients included 368 women (aged 19–45 y): 246 AN, 53 overweight/obese, and 69 lean controls. Main Outcome Measures: HSA-derived femoral geometry, peak factor of risk for hip fracture, and factor of risk for hip fracture attenuated by trochanteric soft tissue (φattenuated) were measured. Results: Most HSA-derived parameters were impaired in AN and superior in obese/overweight women vs controls at the narrow neck, intertrochanteric, and femoral shaft (P ≤ .03). The φattenuated was highest in AN and lowest in overweight/obese women (P < .0001). Lean mass was associated with superior, and duration of amenorrhea with inferior, HSA-derived parameters and φattenuated (P < .05). Mean φattenuated (P = .036), but not femoral neck BMD or HSA-estimated geometry, was impaired in women who had experienced fragility fractures. Conclusions: Femoral geometry by HSA, hip BMD, and factor of risk for hip fracture attenuated by soft tissue are impaired in AN and superior in obesity, suggesting higher and lower hip fracture risk, respectively. Only attenuated factor of risk was associated with fragility fracture prevalence, suggesting that variability in soft tissue padding may help explain site-specific fracture risk not captured by BMD. PMID:25062461
Recnik, G; Kralj-Iglic, V; Iglic, A; Antolic, V; Kramberger, S; Rigler, I; Pompe, B; Vengust, R
2009-07-01
The aim of our study was to explore whether earlier hip arthroplasty for idiopathic osteoarthritis (OA) might be explained by enlarged contact stress in the hip joint, and to what amount can that be attributed to obesity and biomechanical constitution of the pelvis. Fifty subjects were selected from a list of consecutive recipients of hip endoprosthesis due to idiopathic OA; standard pelvic radiographs made years prior to surgery were the main selection criteria. For 65 hips resultant hip force and peak contact hip stress normalized to the body weight (R/Wb and p(max)/Wb) were determined from the radiographs with the HIPSTRESS method. Body weight and body mass index (BMI) were obtained with an interview. Regression analysis was used to correlate parameters of obesity (body weight, BMI), biomechanical constitution of the pelvis (R/Wb, p(max)/Wb) and mechanical loading within the hip joint (R, p(max)) with age at hip arthroplasty. Younger age at hip arthroplasty was associated with higher body weight (P=0.009), higher peak contact hip stress normalized to the body weight - p(max)/Wb (P=0.019), higher resultant hip force -R (P=0.027) and larger peak contact hip stress - p(max) (P<0.001), but not with BMI (P=0.121) or R/Wb (P=0.614). Our results suggest that enlarged contact stress (p(max)) plays an important role in rapid progression of hip OA with both obesity (increased body weight) and unfavorable biomechanical constitution of the pelvis (greater p(max)/Wb) contributing.
Arthroscopic bursectomy for recalcitrant trochanteric bursitis after hip arthroplasty.
Van Hofwegen, Christopher; Baker, Champ L; Savory, Carlton G; Baker, Champ L
2013-01-01
This study evaluated the use of arthroscopic bursectomy for pain relief in patients with trochanteric bursitis after hip arthroplasty. In this retrospective case series of 12 patients undergoing arthroscopic treatment of recalcitrant trochanteric bursitis after hip arthroplasty, outcomes were assessed via phone interview with a numeric pain rating scale from 1 to 10 and were compared with preoperative pain ratings. Patients were asked the percentage of time they had painless hip function and whether they would have the surgery again. At an average 36-month follow-up (range, 4-85 months), the average numeric pain scale rating improved from 9.3 to 3.3. At an average of 62% of the time, patients had painless use of the hip. Ten of 12 patients in the study felt the pain relief gained was substantial enough to warrant having procedure again. In these patients, arthroscopic bursectomy was a viable option for patients with recalcitrant bursitis after hip arthroplasty.
Hip joint torques during the golf swing of young and senior healthy males.
Foxworth, Judy L; Millar, Audrey L; Long, Benjamin L; Way, Michael; Vellucci, Matthew W; Vogler, Joshua D
2013-09-01
Descriptive, laboratory study. To compare the 3-D hip torques during a golf swing between young and senior healthy male amateur golfers. The secondary purpose was to compare the 3-D hip joint torques between the trail leg and lead leg. The generation of hip torques from the hip musculature is an important aspect of the golf swing. Golf is a very popular activity, and estimates of hip torques during the golf swing have not been reported. Twenty healthy male golfers were divided into a young group (mean ± SD age, 25.1 ± 3.1 years) and a senior group (age, 56.9 ± 4.7 years). All subjects completed 10 golf swings using their personal driver. A motion capture system and force plates were used to obtain kinematic and kinetic data. Inverse dynamic analyses were used to calculate 3-D hip joint torques of the trail and lead limbs. Two-way analyses of covariance (group by leg), with club-head velocity as a covariate, were used to compare peak hip torques between groups and limbs. Trail-limb hip external rotator torque was significantly greater in the younger group compared to the senior group, and greater in the trail leg versus the lead leg. When adjusting for club-head velocity, young and senior healthy male amateur golfers generated comparable hip torques during a golf swing, with the exception of the trail-limb hip external rotator torque. The largest hip torque found was the trail-limb hip extensor torque.
Winters, Michael V; Blake, Charles G; Trost, Jennifer S; Marcello-Brinker, Toni B; Lowe, Lynne M; Garber, Matthew B; Wainner, Robert S
2004-09-01
Active stretching is purported to stretch the shortened muscle and simultaneously strengthen the antagonist muscle. The purpose of this study was to determine whether active and passive stretching results in a difference between groups at improving hip extension range of motion in patients with hip flexor muscle tightness. Thirty-three patients with low back pain and lower-extremity injuries who showed decreased range of motion, presumably due to hip flexor muscle tightness, completed the study. The subjects, who had a mean age of 23.6 years (SD = 5.3, range = 18-25), were randomly assigned to either an active home stretching group or a passive home stretching group. Hip extension range of motion was measured with the subjects in the modified Thomas test position at baseline and 3 and 6 weeks after the start of the study. Range of motion in both groups improved over time, but there were no differences between groups. The results indicate that passive and active stretching are equally effective for increasing range of motion, presumably due to increased flexibility of tight hip flexor muscles. Whether the 2 methods equally improve flexibility of other muscle groups or whether active stretching improves the function of the antagonist muscles is not known. Active and passive stretching both appeared to increase the flexibility of tight hip flexor muscles in patients with musculoskeletal impairments.
The outcome of hip exercise in patellofemoral pain: A systematic review.
Thomson, Catherine; Krouwel, Oliver; Kuisma, Raija; Hebron, Clair
2016-12-01
Patellofemoral pain (PFP) is one of the most common lower extremity conditions seen in clinical practice. Current evidence shows that there are hip strength deficits, delayed onset and shorter activation of gluteus medius in people with PFP. The aim of this review was to systematically review the literature to investigate the outcome of hip exercise in people with PFP. AMED, CINAHL, Cochrane, EMBASE, PEDro, Pubmed, Science direct and SPORTDiscus databases were searched from inception to November 2014 for RCTs, non-randomised studies and case studies. Two independent reviewers assessed each paper for inclusion and quality. Twenty one papers were identified; eighteen investigating strengthening exercise, two investigating the effect of neuromuscular exercise and one study investigated the effect of hip exercise for the prevention of PFP. Hip and knee strengthening programmes were shown to be equally effective. Limited evidence indicates that the addition of hip exercise to an exercise programme is beneficial. Limited evidence demonstrates that motor skill retraining in a participant group who displayed abnormal hip alignment in running improves pain. The evidence consistently demonstrated that both hip strengthening and neuromuscular exercise has a beneficial effect on pain and function in people with PFP. Strengthening exercise predominantly addressed abductor and external rotator muscle groups. A consensus from PFP researchers for standardisation of methodology is recommended to enable meaningful comparison between trials. Copyright © 2016 Elsevier Ltd. All rights reserved.
Magalhães, Eduardo; Silva, Ana Paula M C C; Sacramento, Sylvio N; Martin, RobRoy L; Fukuda, Thiago Y
2013-08-01
The purpose of the study was to compare hip agonist-antagonist isometric strength ratios between females with patellofemoral pain (PFP) syndrome and pain-free control group. One hundred and twenty females between 15 and 40 years of age (control group: n = 60; PFP group: n = 60) participated in the study. Hip adductor, abductor, medial rotator, lateral rotator, flexor, and extensor isometric strength were measured using a hand-held dynamometer. Comparisons in the hip adductor/abductor and medial/lateral rotator and flexor/extensor strength ratios were made between groups using independent t-tests. Group comparisons also were made between the anteromedial hip complex (adductor, medial rotator, and flexor musculature) and posterolateral hip complex (abductor, lateral rotator, and extensor musculature). On average, the hip adductor/abductor isometric strength ratio in the PFP group was 23% higher when compared with the control group (p = 0.01). The anteromedial/posterolateral complex ratio also was significantly higher in the PFP group (average 8%; p = 0.04). No significant group differences were found for the medial/lateral rotator ratio and flexor/extensor strength ratios. The results of this study demonstrate that females with PFP have altered hip strength ratios when compared with asymptomatic controls. These strength imbalances may explain the tendency of females with PFP to demonstrate kinematic tendencies that increase loading on the patellofemoral joint (i.e., dynamic knee valgus).
Schousboe, J T; Paudel, M L; Taylor, B C; Kats, A M; Virnig, B A; Dowd, B E; Langsetmo, L; Ensrud, K E
2017-03-01
Older women with pre-fracture slow walk speed, high body mass index, and/or a high level of multimorbidity have significantly higher health care costs after hip fracture compared to those without those characteristics. Studies to investigate if targeted health care interventions for these individuals can reduce hip fracture costs are warranted. The aim of this study is to estimate the associations of individual pre-fracture characteristics with total health care costs after hip fracture, using Study of Osteoporotic Fractures (SOF) cohort data linked to Medicare claims. Our study population was 738 women age 70 and older enrolled in Medicare Fee for Service (FFS) who experienced an incident hip fracture between January 1, 1992 and December 31, 2009. We assessed pre-fracture individual characteristics at SOF study visits and estimated costs of hospitalizations, skilled nursing facility and inpatient rehabilitation stays, home health care visits, and outpatient utilization from Medicare FFS claims. We used generalized linear models to estimate the associations of predictor variables with total health care costs (2010 US dollars) after hip fracture. Median total health care costs for 1 year after hip fracture were $35,536 (inter-quartile range $24,830 to $50,903). Multivariable-adjusted total health care costs for 1 year after hip fracture were 14 % higher ($5256, 95 % CI $156 to $10,356) in those with walk speed <0.6 m/s compared to ≥1.0 m/s, 25 % higher ($9601, 95 % CI $3314 to $16,069) in those with body mass index ≥30 kg/m 2 compared to 20 to 24.9 mg/kg 2 , and 21 % higher ($7936, 95 % CI $346 to $15,526) for those with seven or more compared to no comorbid medical conditions. Pre-fracture poor mobility, obesity, and multiple comorbidities are associated with higher total health care costs after hip fracture in older women. Studies to investigate if targeted health care interventions for these individuals can reduce the costs of hip fractures are warranted.
Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong
2018-01-08
Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.
Roux, C; Wyman, A; Hooven, F H; Gehlbach, S H; Adachi, J D; Chapurlat, R D; Compston, J E; Cooper, C; Díez-Pérez, A; Greenspan, S L; Lacroix, A Z; Netelenbos, J C; Pfeilschifter, J; Rossini, M; Saag, K G; Sambrook, P N; Silverman, S; Siris, E S; Watts, N B; Boonen, S
2012-12-01
Among 50,461 postmenopausal women, 1,822 fractures occurred (57% minor non-hip, non-vertebral [NHNV], 26% major NHNV, 10% spine, 7% hip) over 1 year. Spine fractures had the greatest detrimental effect on EQ-5D, followed by major NHNV and hip fractures. Decreases in physical function and health status were greatest for spine or hip fractures. There is growing evidence that NHNV fractures result in substantial morbidity and healthcare costs. The aim of this prospective study was to assess the effect of these NHNV fractures on quality of life. We analyzed the 1-year incidences of hip, spine, major NHNV (pelvis/leg, shoulder/arm) and minor NHNV (wrist/hand, ankle/foot, rib/clavicle) fractures among women from the Global Longitudinal study of Osteoporosis in Women (GLOW). Health-related quality of life (HRQL) was analyzed using the EuroQol EQ-5D tool and the SF-36 health survey. Among 50,461 women analyzed, there were 1,822 fractures (57% minor NHNV, 26% major NHNV, 10% spine, 7% hip) over 1 year. Spine fractures had the greatest detrimental effect on EQ-5D summary scores, followed by major NHNV and hip fractures. The number of women with mobility problems increased most for those with major NHNV and spine fractures (both +8%); spine fractures were associated with the largest increases in problems with self care (+11%), activities (+14%), and pain/discomfort (+12%). Decreases in physical function and health status were greatest for those with spine or hip fractures. Multivariable modeling found that EQ-5D reduction was greatest for spine fractures, followed by hip and major/minor NHNV. Statistically significant reductions in SF-36 physical function were found for spine fractures, and were borderline significant for major NHNV fractures. This prospective study shows that NHNV fractures have a detrimental effect on HRQL. Efforts to optimize the care of osteoporosis patients should include the prevention of NHNV fractures.
Hip fracture patients in India have vitamin D deficiency and secondary hyperparathyroidism.
Dhanwal, D K; Sahoo, S; Gautam, V K; Saha, R
2013-02-01
This study evaluated the parameters of bone mineral homeostasis including 25(OH)D and PTH in 90 Indian patients with hip fracture and 90 controls. Hypovitaminosis D, secondary hyperparathyroidism, and biochemical osteomalacia was present in 77, 69, and 50 % patients, respectively, significantly higher compared to controls. Vitamin D deficiency is an important risk factor for hip fracture. The prevalence of vitamin D deficiency is not well known in hip fracture patients from India. Therefore, the present study was conducted to evaluate the parameters of bone mineral homeostasis including 25(OH)D and intact PTH in hip fracture from North India. Ninety consecutive patients with hip fracture and similar number of age- and sex-matched controls were enrolled in the study. The fasting venous samples were analyzed for 25-hydroxyvitamin D (25-OHD), intact parathyroid hormone (PTH), alkaline phosphatase (ALP), calcium, and phosphorus. Vitamin D deficiency was defined as serum 25-OHD of <20 ng/dl. The mean age of hip fracture subjects was 65.9 ± 12.6 which was comparable in men and women. Majority of study subjects were women (70 women and 20 men). The serum 25(OH)D and calcium levels were significantly lower, whereas the intact PTH and ALP levels were significantly higher in patients compared to controls. There was significant negative correlation between serum 25(OH)D and PTH. In the hip fracture group, 76.7 % of the subjects had vitamin D deficiency, and 68.9 % had secondary hyperparathyroidism. In the control group, vitamin D deficiency and elevated PTH levels were seen in 32.3 and 42.2 %, respectively. About three fourths of hip fracture patients have vitamin D deficiency, and two thirds have secondary hyperparathyroidism. Therefore, the serum 25-OHD level may be a useful index for the assessment of risk of hip fracture in India.
Oshikawa, Tomoki; Morimoto, Yasuhiro; Kaneoka, Koji
2018-01-01
[Purpose] To compare the lumbar lordosis angle and electromyographic activities of the trunk and lower-limb muscles in the hip neutral position and external rotation during back squats. [Subjects and Methods] Ten healthy males without severe low back pain or lower-limb injury participated in this study. The lumbar lordosis angle and electromyographic activities were measured using three-dimensional motion-capture systems and surface electrodes during four back squats: parallel back squats in the hip neutral position and external rotation and full back squats in the hip neutral position and external rotation. A paired t-test was used to compare parallel and full back squats measurements in the hip neutral position and external rotation, respectively. [Results] During parallel back squats, the average lumbar lordosis angle was significantly larger in hip external rotation than in the hip neutral position. During full back squats, lumbar erector spinae and multifidus activities were significantly lower in hip external rotation than in the hip neutral position, whereas gluteus maximus activity was significantly higher in hip external rotation than in the hip neutral position. [Conclusion] The back squat in hip external rotation induced improvement of lumbar kyphosis, an increasing of the gluteus maximus activity and a decrease of both lumbar erector spinae and multifidus activities. PMID:29581666
Ipsilateral hip abductor weakness after inversion ankle sprain.
Friel, Karen; McLean, Nancy; Myers, Christine; Caceres, Maria
2006-01-01
Hip stability and strength are important for proper gait mechanics and foot position during heel strike. To determine the relationships between hip muscle strength and chronic ankle sprains and hip muscle strength and ankle range of motion. Ex post facto design with the uninvolved limb serving as the control. Laboratory. A total of 23 subjects with unilateral chronic ankle sprain were recruited. Subjects had at least 2 ipsilateral ankle sprains and were bearing full weight, with the most recent injury occurring at least 3 months earlier. They were not undergoing formal or informal rehabilitation at the time of the study. We obtained goniometric measurements for all planes of motion at the ankle. Handheld dynamometry was used to assess the strength of the hip abductor and hip extensor muscles in both limbs. Hip abductor muscle strength and plantar flexion were significantly less on the involved side than the uninvolved side (P < .001 in each case). Strength of the involved hip abductor and hip extensor muscles was significantly correlated (r = 0.539, P < .01). No significant difference was noted in hip extensor muscle strength between sides (P = .19). Our subjects with unilateral chronic ankle sprains had weaker hip abduction strength and less plantar-flexion range of motion on the involved sides. Clinicians should consider exercises to increase hip abduction strength when developing rehabilitation programs for patients with ankle sprains.
Mattei, Lorenza; Di Puccio, Francesca; Joyce, Thomas J; Ciulli, Enrico
2015-03-01
In the present study, numerical and experimental wear investigations on reverse total shoulder arthroplasties (RTSAs) were combined in order to estimate specific wear coefficients, currently not available in the literature. A wear model previously developed by the authors for metal-on-plastic hip implants was adapted to RTSAs and applied in a double direction: firstly, to evaluate specific wear coefficients for RTSAs from experimental results and secondly, to predict wear distribution. In both cases, the Archard wear law (AR) and the wear law of UHMWPE (PE) were considered, assuming four different k functions. The results indicated that both the wear laws predict higher wear coefficients for RTSA with respect to hip implants, particularly the AR law, with k values higher than twofold the hip ones. Such differences can significantly affect predictive wear model results for RTSA, when non-specific wear coefficients are used. Moreover, the wear maps simulated with the two laws are markedly different, although providing the same wear volume. A higher wear depth (+51%) is obtained with the AR law, located at the dome of the cup, while with the PE law the most worn region is close to the edge. Taking advantage of the linear trend of experimental volume losses, the wear coefficients obtained with the AR law should be valid despite having neglected the geometry update in the model. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kinematic determinants of weapon velocity during the fencing lunge in experienced épée fencers.
Bottoms, Lindsay; Greenhalgh, Andrew; Sinclair, Jonathan
2013-01-01
The lunge is the most common attack in fencing, however there is currently a paucity of published research investigating the kinematics of this movement. The aim of this study was to investigate if kinematics measured during the épée fencing lunge had a significant effect on sword velocity at touch and whether there were any key movement tactics that produced the maximum velocity. Lower extremity kinematic data were obtained from fourteen right handed club épée fencers using a 3D motion capture system as they completed simulated lunges. A forward stepwise multiple linear regression was performed on the data. The overall regression model yielded an Adj R2 of 0.74, p ≤ 0.01. The results show that the rear lower extremity's knee range of motion, peak hip flexion and the fore lower extremity's peak hip flexion all in the sagittal plane were significant predictors of sword velocity. The results indicate that flexion of the rear extremity's knee is an important predictor, suggesting that the fencer sits low in their stance to produce power during the lunge. Furthermore it would appear that the magnitude of peak flexion of the fore extremity's hip was a significant indicator of sword velocity suggesting movement of fore limbs should also be considered in lunge performance.
Residual stress prediction in a powder bed fusion manufactured Ti6Al4V hip stem
NASA Astrophysics Data System (ADS)
Barrett, Richard A.; Etienne, Titouan; Duddy, Cormac; Harrison, Noel M.
2017-10-01
Powder bed fusion (PBF) is a category of additive manufacturing (AM) that is particularly suitable for the production of 3D metallic components. In PBF, only material in the current build layer is at the required melt temperature, with the previously melted and solidified layers reducing in temperature, thus generating a significant thermal gradient within the metallic component, particularly for laser based PBF components. The internal thermal stresses are subsequently relieved in a post-processing heat-treatment step. Failure to adequately remove these stresses can result in cracking and component failure. A prototype hip stem was manufactured from Ti6Al4V via laser PBF but was found to have fractured during over-seas shipping. This study examines the evolution of thermal stresses during the laser PBF manufacturing and heat treatment processes of the hip stem in a 2D finite element analysis (FEA) and compares it to an electron beam PBF process. A custom written script for the automatic conversion of a gross geometry finite element model into a thin layer- by-layer finite element model was developed. The build process, heat treatment (for laser PBF) and the subsequent cooling were simulated at the component level. The results demonstrate the effectiveness of the heat treatment in reducing PBF induced thermal stresses, and the concentration of stresses in the region that fractured.
Position-Specific Hip and Knee Kinematics in NCAA Football Athletes
Deneweth, Jessica M.; Pomeroy, Shannon M.; Russell, Jason R.; McLean, Scott G.; Zernicke, Ronald F.; Bedi, Asheesh; Goulet, Grant C.
2014-01-01
Background: Femoroacetabular impingement is a debilitating hip condition commonly affecting athletes playing American football. The condition is associated with reduced hip range of motion; however, little is known about the range-of-motion demands of football athletes. This knowledge is critical to effective management of this condition. Purpose: To (1) develop a normative database of game-like hip and knee kinematics used by football athletes and (2) analyze kinematic data by playing position. The hypothesis was that kinematics would be similar between running backs and defensive backs and between wide receivers and quarterbacks, and that linemen would perform the activities with the most erect lower limb posture. Study Design: Descriptive laboratory study. Methods: Forty National Collegiate Athletic Association (NCAA) football athletes, representing 5 playing positions (quarterback, defensive back, running back, wide receiver, offensive lineman), executed game-like maneuvers while lower body kinematics were recorded via optical motion capture. Passive hip range of motion at 90° of hip flexion was assessed using a goniometer. Passive range of motion, athlete physical dimensions, hip function, and hip and knee rotations were submitted to 1-way analysis of variance to test for differences between playing positions. Correlations between maximal hip and knee kinematics and maximal hip kinematics and passive range of motion were also computed. Results: Hip and knee kinematics were similar across positions. Significant differences arose with linemen, who used lower maximal knee flexion (mean ± SD, 45.04° ± 7.27°) compared with running backs (61.20° ± 6.07°; P < .001) and wide receivers (54.67° ± 6.97°; P = .048) during the cut. No significant differences were found among positions for hip passive range of motion (overall means: 102° ± 15° [flexion]; 25° ± 9° [internal rotation]; 25° ± 8° [external rotation]). Several maximal hip measures were found to negatively correlate with maximal knee kinematics. Conclusion: A normative database of hip and knee kinematics utilized by football athletes was developed. Position-specific analyses revealed that linemen use smaller joint motions when executing dynamic tasks but do not demonstrate passive range of motion deficits compared with other positions. Clinical Relevance: Knowledge of requisite game-like hip and knee ranges of motion is critical for developing goals for nonoperative or surgical recovery of hip and knee range of motion in the symptomatic athlete. These data help to identify playing positions that require remedial hip-related strength and conditioning protocols. Negative correlations between hip and knee kinematics indicated that constrained hip motion, as seen in linemen, could promote injurious motions at the knee. PMID:26535334
The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.
Maru, M M; Amaral, M; Rodrigues, S P; Santos, R; Gouvea, C P; Archanjo, B S; Trommer, R M; Oliveira, F J; Silva, R F; Achete, C A
2015-09-01
The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and this constitutes the aim of the present work. Hip joint wear simulator tests were performed with cups and heads made of silicon nitride coated with NCD of ~10 μm in thickness. Five million testing cycles (Mc) were run, which represent nearly five years of hip joint implant activity in a patient. For the wear analysis, gravimetry, profilometry, scanning electron microscopy and Raman spectroscopy techniques were used. After 0.5 Mc of wear test, truncation of the protruded regions of the NCD film happened as a result of a fine-scale abrasive wear mechanism, evolving to extensive plateau regions and highly polished surface condition (Ra<10nm). Such surface modification took place without any catastrophic features as cracking, grain pullouts or delamination of the coatings. A steady state volumetric wear rate of 0.02 mm(3)/Mc, equivalent to a linear wear of 0.27 μm/Mc favorably compares with the best performance reported in the literature for the fourth generation alumina ceramic (0.05 mm(3)/Mc). Also, squeaking, quite common phenomenon in hard-on-hard systems, was absent in the present all-NCD system. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rath, Santosh; Yadav, Lalit; Tewari, Abha; Chantler, Tracey; Woodward, Mark; Kotwal, Prakash; Jain, Anil; Dey, Aparajit; Garg, Bhavuk; Malhotra, Rajesh; Goel, Ashish; Farooque, Kamran; Sharma, Vijay; Webster, Premila; Norton, Robyn
2017-12-01
Evidence-based management can reduce deaths and suffering of older adults with hip fractures. This study investigates the evidence-practice gaps in hip fracture care in three major hospitals in Delhi, potential barriers and facilitators to improving care, and consequently, identifies contextually appropriate interventions for implementing best practice for management of older adults with hip fractures in India. Hip fracture in older adults is a significant public health issue in India. The current study sought to document current practices, identify barriers and facilitators to adopting best practice guidelines and recommend improvements in the management of older adults with hip fractures in Delhi, India. This mixed methods observational study collected data from healthcare providers, patients, carers and medical records from three major public tertiary care hospitals in Delhi, India. All patients aged ≥50 years with an X-ray confirmed hip fracture that were admitted to these hospitals over a 10-week period were recruited. Patients' data were collected at admission, discharge and 30 days post-injury. Eleven key informant interviews and four focus group discussions were conducted with healthcare providers. Descriptive data for key quantitative variables were computed. The qualitative data were analysed and interpreted using a behaviour change wheel framework. A total of 136 patients, 74 (54%) men and 62 women, with hip fracture were identified in the three participating hospitals during the recruitment period and only 85 (63%) were admitted for treatment with a mean age of 66.5 years (SD 11.9). Of these, 30% received surgery within 48 h of hospital admission, 95% received surgery within 39 days of hospital admission and two (3%) had died by 30 days of injury. According to the healthcare providers, inadequate resources and overcrowding prevent adequate caring of the hip fracture patients. They unanimously felt the need for protocol-based management of hip fracture in India. The development and implementation of national guidelines and standardized protocols of care for older people with hip fractures in India has the potential to improve both care and patient-related outcomes.
Hip and Shoulder Range of Motion in Youth Baseball Pitchers.
Oliver, Gretchen D; Weimar, Wendi H
2016-10-01
Oliver, GD and Weimar, WH. Hip and shoulder range of motion in youth baseball pitchers. J Strength Cond Res 30(10): 2823-2827, 2016-Lack of range of motion (ROM) has long been suspected as contributing to injury in baseball pitchers. However, all previous ROM research has focused on collegiate and professional pitchers. It was thus the purpose of this study to measure and evaluate bilateral hip and throwing shoulder rotational passive range of motion (PROM) in youth baseball pitchers. Twenty-six youth baseball pitchers (11.3 ± 1.0 years; 152.4 ± 9.0 cm; 47.5 ± 11.3 kg) with no history of injury participated. Bilateral hip and throwing shoulder rotational PROM was measured. There were no significant side-to-side differences for the hip variables (p ≥ 0.05). Shoulder external rotation (ER) was significantly greater than shoulder internal rotation (IR). And the lead leg hip had significantly greater ER than IR. Shoulder ER revealed significant correlations with both lead and stance hip IR (r = 0.45, p = 0.02 and r = 0.48, p = 0.01, respectively). The youth baseball pitchers in this study displayed similar PROM patterns as collegiate and professional baseball pitchers. Additionally, our youth baseball pitchers also presented strong relationships between hip and shoulder PROM. This study reveals that the PROM patterns displayed by these youth may indicate that their available ROM could survive maturation. It is therefore suggested that clinical focus be directed to maintaining hip and shoulder rotational ROM throughout maturation in attempt to determine a possible relations between injurious mechanisms and performance enhancement.
Wellsandt, E; Zeni, J A; Axe, M J; Snyder-Mackler, L
2017-12-01
Anterior cruciate ligament injury results in altered kinematics and kinetics in the knee and hip joints that persist despite surgical reconstruction and rehabilitation. Abnormal movement patterns and a history of osteoarthritis are risk factors for articular cartilage degeneration in additional joints. The purpose of this study was to determine if hip joint biomechanics early after anterior cruciate ligament injury and reconstruction differ between patients with and without post-traumatic knee osteoarthritis 5years after reconstruction. The study's rationale was that individuals who develop knee osteoarthritis after anterior cruciate ligament injury may also demonstrate large alterations in hip joint biomechanics. Nineteen athletes with anterior cruciate ligament injury completed standard gait analysis before (baseline) and after (post-training) extended pre-operative rehabilitation and at 6months, 1year, and 2years after reconstruction. Weightbearing knee radiographs were completed 5years after reconstruction to identify medial compartment osteoarthritis. Five of 19 patients had knee osteoarthritis at 5years after anterior cruciate ligament reconstruction. Patients with knee osteoarthritis at 5years walked with smaller sagittal plane hip angles (P: 0.043) and lower sagittal (P: 0.021) and frontal plane (P: 0.042) external hip moments in the injured limb before and after reconstruction compared to those without knee osteoarthritis. The current findings suggest hip joint biomechanics may be altered in patients who develop post-traumatic knee osteoarthritis. Further study is needed to confirm whether the risk of non-traumatic hip pathology is increased after anterior cruciate ligament injury and if hip joint biomechanics influence its development. Copyright © 2017 Elsevier Ltd. All rights reserved.
Marghalani, Siham; Feller, John Kyle; Mahalingam, Meera; Mirzabeigi, Marjan
2015-06-01
Huntington interacting protein 1 (HIP1), an antiapoptotic protein normally expressed in the brain, is highly expressed in Merkel cell carcinomas (MCCs). Given this, the aim of the current study was to ascertain the value of HIP1 as a histopathologic adjunct in the diagnosis of MCC. In this retrospective study, archival material from 26 cases with a diagnosis of MCC and/or neuroendocrine carcinoma were retrieved from the pathology files of the Skin Pathology Laboratory (Boston University School of Medicine, Boston, MA, USA). Histopathologic sections of all cases were re-reviewed and the diagnosis confirmed. All patient data were de-identified. Immunohistochemical studies were performed using antibodies to HIP1 and cytokeratins (CK) 20 and 7. A semiquantitative scoring system for immunohistochemical expression of HIP1 was utilized by deriving a cumulative score (based on percentage positivity of cells and intensity of expression). Using a cut-off total score of 3 or more as positive, the total number of positive cases was 22 for HIP1, 24 for CK20, and 11 for CK7. Comparing the results of HIP1 and CK20, there were four discordant pairs (three positive for CK20 but negative for HIP1 and one positive for HIP1 but negative for CK20). McNemar's test indicated that there was no statistical significance (P = 0.625), thereby implying a close agreement between the expression of HIP1 and CK20 in these neuroendocrine neoplasms. © 2014 The International Society of Dermatology.
Lenzlinger-Asprion, Rahel; Keller, Niculina; Meichtry, André; Luomajoki, Hannu
2017-01-31
Hip joint complaints are a problem associated with increasing age and impair the mobility of a large section of the elderly population. Reliable and valid tests are necessary for a thorough investigation of a joint. A fundamental function of the hip joint is movement control and a test of this function forms a part of the standard examination. Until now there have been few scientific studies which specifically investigate the reliability of measurement tests of movement control of the hip joint. The aim of this study was to examine the intratester and intertester reliability of the movement control tests of the hip joint which are in use in current clinical practice. Sixteen participants with hip joint complaints and 14 without hip joint impairment were recruited. All participants performed five active movement control tests for the hip joint and were video filmed whilst performing these tests. These films formed the basis for the evaluation and were assessed by two independent physiotherapists. For the intertester and intratester reliability calculations specially set weighted kappa values and the calculated percentages were used. The intertester reliability of the five examined movement control tests of the hip joint showed good to almost perfect values (weighted kappa (wk) = 0.56-0.87). The intratester reliability of the more experienced evaluator A was better in regards to the less experienced evaluator B (average wk = 0.62 vs 0.38). The visual evaluation of movement control tests of the hip joint is especially reliable when carried out by an experienced evaluator. 4 out of 5 tests also showed good results for intertester reliability and support their use in clinical practice.
Verlinden, Vincentius J A; de Kruijf, Marjolein; Bierma-Zeinstra, Sita M A; Hofman, Albert; Uitterlinden, André G; Ikram, M Arfan; van Meurs, Joyce B J; van der Geest, Jos N
2017-05-01
Hip and knee osteoarthritis (OA) are debilitating diseases that impair gait at severe stages. Although associations between OA and gait are established for normal walking, little is known about its relation with turning and tandem (heel-to-toe) walking. Furthermore, it is unknown how asymptomatic OA associates with gait, and whether associations differ by sex. We investigated how symptomatic and asymptomatic hip and knee OA associate with gait in community-dwelling individuals. In 2706 participants of a population-based cohort study, gait was assessed by electronic walkway and summarised into seven gait domains. Hip and knee radiographs were graded for radiographic OA (ROA) using the Kellgren and Lawrence (K&L) score. Linear regression was used to investigate associations between ROA and gait. Analyses were repeated including only participants with asymptomatic ROA, defined as a K&L-score of 2 without pain. In total, 177 participants (6.5%) had hip ROA and 441 (16.3%) knee ROA. We found no associations of knee ROA with gait. Hip ROA associated with Rhythm, Tandem, and Turning. Furthermore, unilateral hip ROA associated with larger gait asymmetry and gait differences in osteoarthritic and non-osteoarthritic leg, when compared to people without hip ROA. Associations between hip ROA and gait were generally stronger for women than men. Associations for hip ROA remained after restricting to asymptomatic ROA. Hip ROA, but not knee ROA, associates with gait differences in normal walking, turning, and tandem walking in community-dwelling individuals. These associations differ between the sexes, and are already present for asymptomatic ROA. Copyright © 2017 Elsevier B.V. All rights reserved.
Porter, David; Michael, Shona; Kirkwood, Craig
2007-12-01
To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/ dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Cross-sectional observational study. Posture management services in three centres in the UK. Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. A total of 747 participants were included in the study, aged 6-80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P<0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P=0.007), hips subluxed on the left (P=0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P=0.03) were observed. The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed.
Michael, Shona; Kirkwood, Craig
2008-01-01
Objective: To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Design: Cross-sectional observational study. Setting: Posture management services in three centres in the UK. Subjects: Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Main measures: Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. Results: A total of 747 participants were included in the study, aged 6–80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P < 0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P = 0.007), hips subluxed on the left (P = 0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P = 0.03) were observed. Conclusions: The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed. PMID:18042604
Solomonow-Avnon, Deborah; Haim, Amir; Levin, Daniel; Elboim-Gabyzon, Michal; Rozen, Nimrod; Peled, Eli; Wolf, Alon
2016-10-01
Loading/excessive loading of the hip joint has been linked to onset and progression of hip osteoarthritis. Footwear-generated biomechanical manipulation in the frontal plane has been previously shown in a cohort of healthy subjects to cause a specific gait adaption when the foot center of pressure trajectory was shifted medially, which thereby significantly reduced hip joint reaction force. The objective of the present study was to validate these results in a cohort of female bilateral hip osteoarthritis patients. Sixteen patients underwent gait analysis while using a footworn biomechanical device, allowing controlled foot center of pressure manipulation, in three para-sagittal configurations: medial, lateral, and neutral. Hip osteoarthritis patients exhibited similar results to those observed in healthy subjects in that a medial center of pressure led to an increase in inter-maleolar distance while step width (i.e., distance between right and left foot center of pressure) remained constant. This adaptation, which we speculate subjects adopt to maintain base of support, was associated with significantly greater hip abduction, significantly decreased hip adduction moment, and significantly reduced joint reaction force compared to the neutral and lateral configurations. Recommendations for treatment of hip osteoarthritis emphasize reduction of loads on the pathological joint(s) during daily activities and especially in gait. Our results show that a medially deviated center of pressure causes a reduction in hip joint reaction force. The present study does not prove, but rather suggests, clinical significance, and further investigation is required to assess clinical implications. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1762-1771, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Bagwell, Jennifer J; Snibbe, Jason; Gerhardt, Michael; Powers, Christopher M
2016-01-01
Previous studies have indicated that hip and pelvis kinematics may be altered during functional tasks in persons with femoroacetabular impingement. The purpose of this study was to compare hip and pelvis kinematics and kinetics during a deep squat task between persons with cam femoroacetabular impingement and pain-free controls. Fifteen persons with cam femoroacetabular impingement and 15 persons without cam femoroacetabular impingement performed a deep squat task. Peak hip flexion, abduction, and internal rotation, and mean hip extensor, adductor, and external rotator moments were quantified. Independent t-tests (α<0.05) were used to evaluate between group differences. Compared to the control group, persons with cam femoroacetabular impingement demonstrated decreased peak hip internal rotation (15.2° (SD 9.5°) vs. 9.4° (SD 7.8°); P=0.041) and decreased mean hip extensor moments (0.56 (SD 0.12) Nm/kg vs. 0.45 (SD 0.15) Nm/kg; P=0.018). In addition persons in the cam femoroacetabular impingement group demonstrated decreased posterior pelvis tilt during squat descent compared to the control group, resulting in a more anteriorly tilted pelvis at the time peak hip flexion (12.5° (SD 17.1°) vs. 23.0° (SD 12.4°); P=0.024). The decreased hip internal rotation observed in persons with cam femoroacetabular impingement may be the result of bony impingement. Furthermore, the decrease in posterior pelvis tilt may contribute to impingement by further approximating the femoral head-neck junction with the acetabulum. Additionally, decreased hip extensor moments suggest that diminished hip extensor muscle activity may contribute to decreased posterior pelvis tilt. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wu, Chi-Shin; Chang, Chia-Ming; Tsai, Yu-Ting; Huang, Ya-Wen; Tsai, Hui-Ju
2015-09-01
To investigate the association between antipsychotic treatment and risk of hip fracture in subjects with schizophrenia. Among patients with schizophrenia (ICD-9-CM code 295), 605 cases with hip fracture and 2,828 matched controls were identified from 2002 to 2011 using the National Health Insurance Research Database in Taiwan. The authors conducted a nested case-control study to investigate the association between antipsychotic treatment and risk of hip fracture in subjects with schizophrenia. The modifiable effects of age and gender were evaluated by stratified analysis. In addition, the effects of antipsychotic use, antipsychotic classes, and receptor-binding profiles of antipsychotics, individually, on hip fracture were estimated, and potential confounding factors were adjusted in subsequent analysis. Conditional logistic regressions were applied to determine the effect of antipsychotic treatment on hip fracture. Current antipsychotic use was associated with an increased risk for hip fracture (adjusted odds ratio [AOR] = 1.61; 95% CI, 1.24-2.10). Among current users, new users had a higher risk of hip fracture (AOR = 4.28; 95% CI, 1.76-10.36) than past users (AOR = 1.11; 95% CI, 0.79-1.56). In addition, a significant increased risk of hip fracture was noted in schizophrenia subjects with first-generation antipsychotic use (AOR = 1.59; 95%CI, 1.15-2.20) but not in those with second-generation antipsychotic use (AOR = 1.16; 95% CI, 0.91-1.48). These results extend previous findings and demonstrate an increased risk of hip fracture associated with antipsychotic use in schizophrenia subjects. Further investigation is needed to dissect the underlying mechanisms related to the effect of antipsychotic use on hip fracture in subjects at risk. © Copyright 2015 Physicians Postgraduate Press, Inc.
Analysis of Arthroscopic Therapy for hip Pathologies.
Przybył, Michał; Walenczak, Krzysztof; Lebiedziński, Radosław; Domżalski, Marcin
2017-05-10
[b]Background. [/b]This paper analyses the outcomes of treatment of avascular necrosis (AVN), femoroacetabular impingement (FAI), hip labral tear (HLT) and snapping hip syndrome (SHS). Moreover, the results of individual groups are also compared. The study group consisted of 70 persons (surgeries of 72 hips). AVN - 14 patients, FAI - 38 patients (39 hips), HLT - 12 patients (13 hips), SHS - 6 patients. Two questionnaires, namely the MHHS (Modified Harris Hip Score) and NAHS (Non Arthritic Hip Score), were used to evaluate the patients before the surgery and at 6- and 12-month follow-up.[b]Results. [/b]AVN : local improvement was recorded at both 6 and 12 months, FAI: local improvement was recorded at both 6 and 12 months, HLT: local improvement was recorded at both 6 and 12 months, SHS: local improvement was recorded at both 6 and 12 months. Comparison of the results between the groups showed that: At baseline, local status in AVN was poorer than in FAI. At 6- and 12-month follow-up, local status in AVN was poorer than in FAI, HLT and SHS.[b]Conclusions.[/b] AVN Group 1. The study demonstrates that arthroscopic treatment of avascular necrosis produced fairly good outcomes at 6 and 12 months after the surgery. 2. Treatment of avascular necrosis showed significantly poorer results than therapy of femoroacetabular impingement, hip labral tear and snapping hip syndrome at 6 and 12 months. FAI Group 1. Arthroscopic treatment of femoroacetabular impingement produced good outcomes at 6 and 12 months after the surgery. HLT Group 1. Arthroscopic treatment of hip labral tear produced excellent outcomes at 6 and 12 months after the surgery. SHS Group 1. Arthroscopic treat ment of snapping hip syndrome produced excellent outcomes at 6 and 12 months after the surgery.Additional conclusions. 1. Studies showing long-term effect of arthroscopic treatment of selected conditions are necessary to further assess the effectiveness of this treatment. 2. It is necessary to evaluate the influence of the patients' age and severity of osteo arthritis on treatment outcomes in FAI. 3. It is necessary to assess the influence of the severity of pre-operative necrosis according to Ficat and Arlet classification on treatment outcomes in AVN.
Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray
2015-03-01
The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.
Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement
Zhang, Dagang; Chen, Long; Wang, Guanglin
2016-01-01
Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133
Total hip arthroplasty of dysplastic hip after previous Chiari pelvic osteotomy.
Minoda, Yukihide; Kadowaki, Toru; Kim, Mitsunari
2006-08-01
Many reports have suggested that Chiari pelvic osteotomy would improve the results of acetabular component placement and fixation in subsequent total hip arthroplasty. However, little is known concerning the biomechanical, radiological, and clinical effects of Chiari pelvic osteotomy on subsequent total hip arthroplasty. Ten total hip arthroplasties for developmental dysplasia of the hip after previous Chiari pelvic osteotomy (Chiari group) were compared with 20 total hip arthroplasties for developmental dysplasia of the hip without previous surgery (control group). Preoperative patient demographic data and operative technique were well matched between the groups. The mean duration of follow-up was 3.0 years. Biomechanical, radiological, and clinical evaluations were performed. No acetabular or femoral components exhibited loosening. All patients had good or excellent clinical score according to the Merle d'Aubigne-Postel rating system at the most recent follow-up. Abductor force and joint force were smaller in the Chiari group, although long operative time, more blood loss, and verticalization of joint force were noted in this group. This limited study suggested that Chiari pelvic osteotomy changed the biomechanical features of the hip joint, and that this alteration might have compromised subsequent total hip arthroplasty.
Statistical atlas based extrapolation of CT data
NASA Astrophysics Data System (ADS)
Chintalapani, Gouthami; Murphy, Ryan; Armiger, Robert S.; Lepisto, Jyri; Otake, Yoshito; Sugano, Nobuhiko; Taylor, Russell H.; Armand, Mehran
2010-02-01
We present a framework to estimate the missing anatomical details from a partial CT scan with the help of statistical shape models. The motivating application is periacetabular osteotomy (PAO), a technique for treating developmental hip dysplasia, an abnormal condition of the hip socket that, if untreated, may lead to osteoarthritis. The common goals of PAO are to reduce pain, joint subluxation and improve contact pressure distribution by increasing the coverage of the femoral head by the hip socket. While current diagnosis and planning is based on radiological measurements, because of significant structural variations in dysplastic hips, a computer-assisted geometrical and biomechanical planning based on CT data is desirable to help the surgeon achieve optimal joint realignments. Most of the patients undergoing PAO are young females, hence it is usually desirable to minimize the radiation dose by scanning only the joint portion of the hip anatomy. These partial scans, however, do not provide enough information for biomechanical analysis due to missing iliac region. A statistical shape model of full pelvis anatomy is constructed from a database of CT scans. The partial volume is first aligned with the statistical atlas using an iterative affine registration, followed by a deformable registration step and the missing information is inferred from the atlas. The atlas inferences are further enhanced by the use of X-ray images of the patient, which are very common in an osteotomy procedure. The proposed method is validated with a leave-one-out analysis method. Osteotomy cuts are simulated and the effect of atlas predicted models on the actual procedure is evaluated.
Domb, Benjamin G; Linder, Dror; Finley, Zachary; Botser, Itamar B; Chen, Austin; Williamson, Joseph; Gupta, Asheesh
2015-02-01
Age has been suggested as a negative prognostic factor for hip arthroscopy. The purpose of this study was to compare patient characteristics and outcomes after hip arthroscopy in patients aged 50 years or older with a matched control group of patients aged 30 years or younger at a minimum postoperative follow-up of 2 years. Between September 2008 and March 2010, data were prospectively collected on all patients aged 50 years or older undergoing primary hip arthroscopy. Fifty-two patients met our inclusion and matching criteria, of whom all 52 (100%) were available for follow-up at a minimum of 2 years. This cohort was compared with a matched-pair control group of patients aged 30 years or younger who underwent similar procedures. The mean age of the study group was 54.8 years (range, 50 to 69 years), and that of the control group was 20.3 years (range, 13 to 30 years). The groups were matched at a 1:1 ratio, including 18 male patients (34.6%) and 34 female patients (65.4%) in each group, with a mean follow-up period of 32 months (range, 24 to 54 months). In the younger control group, the score improvement from preoperatively to 2 years' follow-up was 62.9 to 84.2 for the modified Harris Hip Score, 60.5 to 84.2 for the Non-Arthritic Hip Score, 63.1 to 86.5 for the Hip Outcome Score-Activities of Daily Living, and 42.2 to 72.7 for the Hip Outcome Score-Sport-Specific Subscale. In the older study group, the score improvement from preoperatively to 2 years' follow-up was 61.2 to 82.2 for the modified Harris Hip Score, 59.9 to 80.4 for the Non-Arthritic Hip Score, 63.9 to 83 for the Hip Outcome Score-Activities of Daily Living, and 41.2 to 64.6 for the Hip Outcome Score-Sport-Specific Subscale. All improvements in both groups were statistically significant at the 2-year postoperative follow-up (P < .001). There was no significant difference for all patient-reported outcome (PRO) scores at final follow-up between both groups. When we compared the change in PRO scores (Δ) from preoperatively to 2 years postoperatively, there was no significant difference between both groups. The overall survivorship rate was 98.1% for the younger control group and 82.7% for the older study group. Survivors aged 50 years or older show similar improvement to patients aged 30 years or younger in PRO and patient satisfaction scores. The 2-year survivorship rate was 98.1% for the younger control group and 82.7% for the older study group. Therefore we believe that hip arthroscopy should be considered a valid treatment option when treating hip pain in patients aged 50 years or older with a Tönnis arthritic grade of 0 or 1. Older patients should be counseled on the possibility of later conversion to total hip arthroplasty. Future work may include development of a decision-making tool to assess for prognosis to better delineate the indications for hip arthroscopy in the older population. Level III, therapeutic case-control study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Structure Determination of Mycobacterium tuberculosis Serine Protease Hip1 (Rv2224c)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naffin-Olivos, Jacqueline L.; Daab, Andrew; White, Andre
The Mycobacterium tuberculosis (Mtb) serine protease Hip1 (hydrolase important for pathogenesis; Rv2224c) promotes tuberculosis (TB) pathogenesis by impairing host immune responses through proteolysis of a protein substrate, Mtb GroEL2. The cell surface localization of Hip1 and its immunomodulatory functions make Hip1 a good drug target for new adjunctive immune therapies for TB. Here, we report the crystal structure of Hip1 to a resolution of 2.6 Å and the kinetic studies of the enzyme against model substrates and the protein GroEL2. The structure shows a two-domain protein, one of which contains the catalytic residues that are the signature of a serinemore » protease. Surprisingly, a threonine is located within the active site close enough to hydrogen bond with the catalytic residues Asp463 and His490. Mutation of this residue, Thr466, to alanine established its importance for function. Our studies provide insights into the structure of a member of a novel family of proteases. Knowledge of the Hip1 structure will aid in designing inhibitors that could block Hip1 activity« less
Abolghasemian, Mansour; Samiezadeh, Saeid; Jafari, Davood; Bougherara, Habiba; Gross, Allan E; Ghazavi, Mohammad T
2013-06-01
To study the direction and biomechanical consequences of hip center of rotation (HCOR) migration in Crowe type III and VI hips after total hip arthroplasty, post-operative radiographs and CT scans of several unilaterally affected hips were evaluated. Using a three-dimensional model of the human hip, the HCOR was moved in all directions, and joint reaction force (JRF) and abductor muscle force (AMF) were calculated for single-leg stance configuration. Comparing to the normal side, HCOR had displaced medially and inferiorly by an average of 23.4% and 20.8%, respectively, of the normal femoral head diameter. Significant decreases in JRF (13%) and AMF (46.13%) were observed in a presumptive case with that amount of displacement. Isolated inferior displacement had a small, increasing effect on these forces. In Crowe type III and IV hips, the HCOR migrates inferiorly and medially after THA, resulting in a decrease in JRF, AMF, and abductor muscle contraction force. Copyright © 2013 Elsevier Inc. All rights reserved.
Tan, Stephen Thong Soon; Tan, Wei Ping Marcus; Jaipaul, Josephine; Chan, Siew Pang; Sathappan, Sathappan S
2017-05-01
The purpose of this study was to compare the clinical outcomes of elderly hip fracture patients who received surgical treatment with those who received non-surgical treatment. This retrospective study involved 2,756 elderly patients with hip fractures who were admitted over a six-year period. The patients' biodata, complications, ambulatory status at discharge and length of hospital stay were obtained from the institution's hip fracture registry. Among the 2,756 hip fracture patients, 2,029 (73.6%) underwent surgical intervention, while 727 (26.4%) opted for non-surgical intervention. The complication rate among the patients who underwent surgical intervention was 6.6%, while that among the patients who underwent non-surgical intervention was 12.5% (p < 0.01). The mean length of hospital stay for the surgical and non-surgical hip fracture patients was 15.7 days and 22.4 days, respectively (p < 0.01). Surgical management of hip fractures among the elderly is associated with a lower complication rate, as well as a reduced length of hospital stay. Copyright: © Singapore Medical Association
Structure Determination of Mycobacterium tuberculosis Serine Protease Hip1 (Rv2224c).
Naffin-Olivos, Jacqueline L; Daab, Andrew; White, Andre; Goldfarb, Nathan E; Milne, Amy C; Liu, Dali; Baikovitz, Jacqueline; Dunn, Ben M; Rengarajan, Jyothi; Petsko, Gregory A; Ringe, Dagmar
2017-05-02
The Mycobacterium tuberculosis (Mtb) serine protease Hip1 (hydrolase important for pathogenesis; Rv2224c) promotes tuberculosis (TB) pathogenesis by impairing host immune responses through proteolysis of a protein substrate, Mtb GroEL2. The cell surface localization of Hip1 and its immunomodulatory functions make Hip1 a good drug target for new adjunctive immune therapies for TB. Here, we report the crystal structure of Hip1 to a resolution of 2.6 Å and the kinetic studies of the enzyme against model substrates and the protein GroEL2. The structure shows a two-domain protein, one of which contains the catalytic residues that are the signature of a serine protease. Surprisingly, a threonine is located within the active site close enough to hydrogen bond with the catalytic residues Asp463 and His490. Mutation of this residue, Thr466, to alanine established its importance for function. Our studies provide insights into the structure of a member of a novel family of proteases. Knowledge of the Hip1 structure will aid in designing inhibitors that could block Hip1 activity.
Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty.
Singh, Nishant Kumar; Rai, Sanjay Kumar; Rastogi, Amit
2017-01-01
Vascular injury during minimally invasive total hip arthroplasty (THA) is uncommon, yet a well-recognized and serious issue. It emerges because of non-visibility of vascular structures proximal to the pelvic bone during reaming, drilling holes, and fixing of screws. Numerous studies have found that screw fixation during cementless THA is beneficial for the initial stability of cup; yet, no anatomical guidelines support angular eccentric screw fixation. In this study, we obtained the pelvic arterial-phase computed tomographic data of thirty eight humans and reconstructed the three-dimensional models of osseous and vessel structures. We performed the surgical simulation to fix these structures with cementless cups and screws with angular eccentricities. The effect of screw eccentricities (angular eccentricities of ±17° and ±34°) on the vascular injury was determined. Measurement between screw and adjoining vessels was performed and analyzed statistically to ascertain a comparative risk study for blood vessels that are not visible during surgery. Authors similarly discussed the significant absence of appreciation of quadrant systems proposed by Wasielewski et al . on eccentric screws. Adjustment of quadrant systems provided by Wasielewski et al . is required for acetabular implants with eccentric holes for fixation of acetabular screws.
Polish Hip Hop as a Form of Multiliteracies and Situated Learning
ERIC Educational Resources Information Center
Torrence, Michael L.
2009-01-01
The purpose of this ethnographic study was to examine Hip Hop in Poland through the lens of multiliteracies and situated learning. This analysis is concerned with the transmission of Hip Hop to and within Wroclaw, Poland, and its acculturation and assimilation in Wroclaw, Poland. Further, this study seeks to illustrate how professional Polish Hip…
Boo, Marie E; Garrison, J Craig; Hannon, Joseph P; Creed, Kalyssa M; Goto, Shiho; Grondin, Angellyn N; Bothwell, James M
2018-03-01
Female patients are more likely to suffer a second anterior cruciate ligament (ACL) injury after ACL reconstruction (ACLR) and return to sport (RTS) compared with healthy female controls. Few studies have examined the energy absorption contribution (EAC) that could lead to this subsequent injury. The ACLR group would demonstrate an altered EAC between joints (hip, knee, and ankle) but no difference in quadriceps, hip abduction, or hip external rotation (ER) strength at the time of RTS. Cross-sectional study; Level of evidence, 3. A total of 34 female participants (ACLR: n = 17; control: n = 17) were enrolled in the study and matched for age and activity level. Jump landing performance for the initial 50 milliseconds of landing of a lateral-vertical jump was assessed using a 10-camera 3-dimensional motion capture system and 2 force plates. Isokinetic quadriceps strength was measured using a Biodex machine, and hip abduction and ER isometric strength were measured using a handheld dynamometer. All values were normalized to the participant's height and weight. A 1-way multivariate analysis of variance was used to assess between-group differences in the EAC at the hip, knee, and ankle. Two 1-way analyses of variance were used to independently examine quadriceps, hip abduction, and hip ER strength between the groups. Significant differences in the EAC were found between the groups for the involved hip ( P = .002), uninvolved hip ( P = .005), and involved ankle ( P = .023). There were no between-group differences in the EAC for the involved or uninvolved knee or the uninvolved ankle. Patients who underwent ACLR demonstrated significantly decreased quadriceps strength on the involved limb ( P = .02) and decreased hip ER strength on both the involved ( P = .005) and uninvolved limbs ( P = .002). No significant strength differences were found between the groups for the uninvolved quadriceps or for involved or uninvolved hip abduction. At RTS, patients who underwent ACLR utilized a greater hip EAC bilaterally and a decreased involved ankle EAC during a lateral-vertical jump. Furthermore, quadriceps strength on the involved limb and hip ER strength of bilateral lower extremities remained decreased. This could place greater stress on the ACL graft and ultimately lead to an increased injury risk.
Faucett, Scott C; Genuario, James W; Tosteson, Anna N A; Koval, Kenneth J
2010-02-01
: A previous hip fracture more than doubles the risk of a contralateral hip fracture. Pharmacologic and environmental interventions to prevent hip fracture have documented poor compliance. The purpose of this study was to examine the cost-effectiveness of prophylactic fixation of the uninjured hip to prevent contralateral hip fracture. : A Markov state-transition model was used to evaluate the cost and quality-adjusted life-years (QALYs) for unilateral fixation of hip fracture alone (including internal fixation or arthroplasty) compared with unilateral fixation and contralateral prophylactic hip fixation performed at the time of hip fracture or unilateral fixation and bilateral hip pad protection. Prophylactic fixation involved placement of a cephalomedullary nail in the uninjured hip and was initially assumed to have a relative risk of a contralateral fracture of 1%. Health states included good health, surgery-related complications requiring a second operation (infection, osteonecrosis, nonunion, and malunion), fracture of the uninjured hip, and death. The primary outcome measure was the incremental cost-effectiveness ratio estimated as cost per QALY gained in 2006 US dollars with incremental cost-effectiveness ratios below $50,000 per QALY gained considered cost-effective. Sensitivity analyses evaluated the impact of patient age, annual mortality and complication rates, intervention effectiveness, utilities, and costs on the value of prophylactic fixation. : In the baseline analysis, in a 79-year-old woman, prophylactic fixation was not found to be cost-effective (incremental cost-effectiveness ratio = $142,795/QALY). However, prophylactic fixation was found to be a cost-effective method to prevent contralateral hip fracture in: 1) women 71 to 75 years old who had 30% greater relative risk for a contralateral fracture; and 2) women younger than age 70 years. Cost-effectiveness was greater when the additional costs of prophylaxis were less than $6000. However, for most analyses, the success of prophylactic fixation was highly sensitive to the effectiveness and the relative morbidity and mortality of the additional procedure. : Prophylactic fixation with a cephalomedullary nail was not found to be cost-effective for the average older woman who sustained a hip fracture. However, it may be appropriate for select patient populations. The study supports the need for basic science and clinical trials investigating the effectiveness of prophylactic fixation for patient populations at higher lifetime risk for contralateral hip fracture.
Cheng, Bi-Hua; Chen, Pau-Chung; Yang, Yao-Hsu; Lee, Chuan-Pin; Huang, Ko-En; Chen, Vincent C
2016-09-01
This study was conducted to investigate the effects of depression and antidepressant medications on hip fracture. The database of the Taiwan National Health Insurance with medical records of more than 1,000,000 individuals was searched for patients who had hip fracture with or without depression from 1998 to 2009. Patients with the following conditions were excluded: hip fracture due to cancer or traffic accidents, hip fracture that occurred before the diagnosis of depression, and use of antidepressants before the diagnosis of depression. A matched cohort of 139,110 patients was investigated, including 27,822 (17,309 females; 10,513 males) with depression and 111,288 (69,236 females; 42,052 males) without depression (1:4 randomly matched with age, sex, and index date). Among these patients, 232 (158 females and 74 males) had both hip fracture and depression, and 690 (473 females and 217 males) had hip fracture only. The Cox proportional-hazards regression method was used to determine the effect of depression on hip fracture. The hazard ratio (HR) for each clinical parameter was calculated after adjusting for confounders including sex, age, Charlson comorbidity index, urbanization, osteoporosis, and antidepressants. Results showed that patients with major depressive disorder had a 61% higher incidence of hip fracture than those without depression (HR 1.61, 95% confidence interval [CI] 1.19-2.18, P = 0.002). The risk of hip fracture for patients with less severe depressive disorder (dysthymia or depressive disorder, not otherwise specified) was not statistically higher than that of patients with no depression (HR 1.10, 95% CI = 0.91-1.34, P = 0.327). Among the patients with depression, females had a 49% higher incidence for hip fracture than males (HR 1.49, 95% CI 1.30-1.72, P < 0.001). The incidence of hip fracture also increased with age and Charlson comorbidity index scores. Analyses of both all (139,110) patients and only patients (27,822) with depression revealed that antidepressants had no negative impact on the incidence of hip fracture. In conclusion, major depression was found to be a risk factor for hip fracture and that use of antidepressants had no adverse effect on hip fracture in the Taiwanese population.
Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.
Liu, F; Jin, Z M; Hirt, F; Rieker, C; Roberts, P; Grigoris, P
2005-09-01
The effect of geometry change of the bearing surfaces owing to wear on the elastohydrodynamic lubrication (EHL) of metal-on-metal (MOM) hip bearings has been investigated theoretically in the present study. A particular MOM Metasul bearing (Zimmer GmbH) was considered, and was tested in a hip simulator using diluted bovine serum. The geometry of the worn bearing surface was measured using a coordinate measuring machine (CMM) and was modelled theoretically on the assumption of spherical geometries determined from the maximum linear wear depth and the angle of the worn region. Both the CMM measurement and the theoretical calculation were directly incorporated into the elastohydrodynamic lubrication analysis. It was found that the geometry of the original machined bearing surfaces, particularly of the femoral head with its out-of-roundness, could lead to a large reduction in the predicted lubricant film thickness and an increase in pressure. However, these non-spherical deviations can be expected to be smoothed out quickly during the initial running-in period. For a given worn bearing surface, the predicted lubricant film thickness and pressure distribution, based on CMM measurement, were found to be in good overall agreement with those obtained with the theoretical model based on the maximum linear wear depth and the angle of the worn region. The gradual increase in linear wear during the running-in period resulted in an improvement in the conformity and consequently an increase in the predicted lubricant film thickness and a decrease in the pressure. For the Metasul bearing tested in an AMTI hip simulator, a maximum total linear wear depth of approximately 13 microm was measured after 1 million cycles and remained unchanged up to 5 million cycles. This resulted in a threefold increase in the predicted average lubricant film thickness. Consequently, it was possible for the Metasul bearing to achieve a fluid film lubrication regime during this period, and this was consistent with the minimal wear observed between 1 and 5 million cycles. However, under adverse in vivo conditions associated with start-up and stopping and depleted lubrication, wear of the bearing surfaces can still occur. An increase in the wear depth beyond a certain limit was shown to lead to the constriction of the lubricant film around the edge of the contact conjunction and consequently to a decrease in the lubricant film thickness. Continuous cycles of a running-in wear period followed by a steady state wear period may be inevitable in MOM hip implants. This highlights the importance of minimizing the wear in these devices during the initial running-in period, particularly from design and manufacturing points of view.
Unver, Bayram; Karatosun, Vasfi; Gunal, Izge; Angin, Salih
2004-02-01
Weight bearing after total hip arthroplasty is postponed in order to prevent early loosening, but this negatively affects the rehabilitation programme. For the force transfer characteristics of thrust plate prosthesis (TPP), a new type of hip prosthesis used without cement is similar to the normal hip. We evaluated the possibilities of early weight bearing after TPP by comparing early partial with early full weight bearing. Randomized controlled study. Department of orthopaedics and traumatology in a university hospital. Sixty hips of 51 patients who underwent total hip arthroplasty with TPP were randomly assigned into two groups. Both groups received accelerated rehabilitation programmes: group 1 with early partial weight bearing and group 2 with early full weight bearing. Patients were evaluated by a blind observer preoperatively, at three months after surgery by clinical (measurement of range of hip motion (universal goniometry), muscle strength (Manual Muscle Test), functional test (6-minute walk test), hip function (Harris Hip Scoring System)) and radiographical parameters and one year after surgery by clinical (Harris Hip Scoring System) and radiographical parameters. Group 2 performed transfer activities earlier, had more walking distance at the time of discharge and shorter hospital stay than group 1. At three months, Harris Hip Score, muscle strength, 6-minute walk test, and duration of crutch use were significantly (p < 0.05) in favour of group 2. None of the patients in either group showed signs of loosening one year after the operation. These results suggest that patients with TPP can tolerate an accelerated rehabilitation programme with early weight bearing and will gain the goals of rehabilitation earlier.
Brief communication: Hip joint mobility in free-ranging rhesus macaques
Hammond, Ashley S.; Johnson, Victoria P.; Higham, James P.
2016-01-01
Objectives We aimed to test for differences in hip joint range of motion (ROM) between captive and free-ranging rhesus macaques (Macaca mulatta), particularly for hip joint abduction, which previous studies of captive macaques have found to be lower than predicted. Materials and Methods Hip ROM was assessed following standard joint measurement methodology in anesthetized adult free-ranging rhesus macaques (n=39) from Cayo Santiago, and compared to published ROM data from captive rhesus macaques (n=16) (Hammond 2014a, American Journal of Physical Anthropology). Significant differences between populations were detected using one-way analysis of variance (p<0.05). Results In a sample of pooled sexes and ages, free-ranging macaques are capable of increased hip abduction, flexion, and internal rotation compared to captive individuals. These differences in joint excursion resulted in free-ranging individuals having significantly increased ROM for hip adduction-abduction, rotation, flexion-extension, and the distance spanned by the knee during hip abduction. When looking at data for a smaller sample of age-matched males, fewer ROM differences are significant, but free-ranging males have significantly increased hip abduction, internal rotation, range of flexion-extension, and distance spanned by the knee during hip abduction compared to captive males of similar age. Discussion Our results suggest that a spatially restrictive environment results in decreased hip mobility in cage-confined animals and ultimately limits the potential limb postures in captive macaques. These results have implications for selection of animal samples in model validation studies, as well as laboratory animal husbandry practices. PMID:27731892
Revision hip preservation surgery with hip arthroscopy: clinical outcomes.
Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J
2014-05-01
To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P < .0001). The visual analog scale score improved from 7.3 ± 1.5 to 3.9 ± 2.5 (P < .0001). Improvements in the Non-Arthritic Hip Score of at least 10 points and 20 points were found in 28 hips (65%) and 19 hips (44%), respectively. Four hips in 3 patients required conversion to total hip arthroplasty. Positive predictive factors for PRO improvement were previous open surgery, pincer impingement, cam impingement, symptomatic heterotopic ossification, and segmental labral defects treated with labral reconstruction. On the basis of multiple PROs, revision hip preservation with hip arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Professional golfers' hips: prevalence and predictors of hip pain with clinical and MR examinations.
Dickenson, Edward; Ahmed, Imran; Fernandez, Miguel; O'Connor, Philip; Robinson, Philip; Campbell, Robert; Murray, Andrew; Warner, Martin; Hutchinson, Charles; Hawkes, Roger; Griffin, Damian
2016-09-01
This study aimed to determine the prevalence of hip pain in professional golfers, comparing the lead (left hip in right-handed golfer) and trail hips, and to establish what player characteristics predicted hip symptoms. Male elite professional golf players were invited to complete questionnaires and undergo clinical and MR examinations while attending the Scottish Hydro Challenge 2015. Questionnaires determined player demographics, self-reported hip pain and an International Hip Outcome Tool 12 (iHOT12) score (hip-related quality of life). Clinical examinations determined hip range of motion and the presence of a positive impingement test. MR scans determined the presence of labral pathology and player hip morphology with measures of α angle (cam), acetabular depth (pincer) and femoral neck antetorsion. A total of 109 (70% of tournament field) of players completed questionnaires, 73 (47%) underwent clinical examination and 55 (35%) underwent MR examination. 19.3% of players reported of hip pain. 11.9% of lead and 9.1% of trail hips were painful (p=0.378), iHOT12 scores were lower in the lead (94.1) compared to the trail hip (95.3) (p=0.007). Stepwise multiple linear regression modelling was able to predict 20.7% of the variance in iHOT12 scores with mean α angles between 12 and 3 o'clock, and increasing age-significant variables (R(2)=0.207, p<0.001; β=-0.502, p<0.001 and β=-0.399, p=0.031, respectively). 19.3% of male professional golfers reported hip pain. The presence of an increasing α angle and increasing age were significant predictors of reduced hip-related quality of life. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Ferreira, Amanda Schenatto; de Oliveira Silva, Danilo; Briani, Ronaldo Valdir; Ferrari, Deisi; Aragão, Fernando Amâncio; Pazzinatto, Marcella Ferraz; de Azevedo, Fábio Mícolis
2018-03-26
Patellofemoral pain (PFP) has been linked to increased patellofemoral joint stress as a result of excessive hip internal rotation. Lower hip strength and/or excessive rearfoot eversion have been used to explain such altered movement pattern; however, it is unknown which one is the best predictor of excessive hip internal rotation. To investigate if peak rearfoot eversion and/or peak concentric hip abductor strength can predict peak hip internal rotation during stair ascent in women with PFP. This cross-sectional study included thirty-seven women with PFP which underwent three-dimensional kinematic analysis during stair ascent and hip abductor strength analysis in an isokinetic dynamometer. A forced entry linear regression model analysis was carried out to determine which independent variables present the best capability to predict the hip internal rotation. Peak concentric hip abductor strength significantly predicted peak hip internal rotation during stair ascent (R 2 = 0.27, p = 0.001). Peak rearfoot eversion did not predict peak hip internal rotation during stair ascent (R 2 < 0.01, p = 0.62). A Post-hoc analysis was conducted to explore if a subgroup with excessive rearfoot eversion would predict hip internal rotation. Based on a previous reported cut-off point, 48.6% of the participants were classified as excessive rearfoot eversion. For the subgroup with excessive rearfoot eversion, peak concentric hip abductor strength and peak rearfoot eversion significantly predicted peak hip internal rotation during stair ascent (R 2 = 0.26, p = 0.02; R 2 = 0.42, p = 0.003, respectively). For non-excessive rearfoot eversion subgroup, peak concentric hip abductor strength significantly predicted peak hip internal rotation during stair ascent (R 2 = 0.53; p < 0.001); and peak rearfoot eversion did not (R 2 = 0.01; p = 0.65). Findings indicate that hip muscle strength seems to be related with hip internal rotation in all women with PFP. Rearfoot eversion seems to be related with hip internal rotation only in a subgroup with excessive rearfoot eversion. Copyright © 2018. Published by Elsevier B.V.
2016-10-06
Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis; Perthes Disease
Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.
Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc
2017-06-01
To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Hip-Abductor Fatigue and Single-Leg Landing Mechanics in Women Athletes
Patrek, Mary F.; Kernozek, Thomas W.; Willson, John D.; Wright, Glenn A.; Doberstein, Scott T.
2011-01-01
Abstract Context: Reduced hip-abductor strength and muscle activation may be associated with altered lower extremity mechanics, which are thought to increase the risk for anterior cruciate ligament injury. However, experimental evidence supporting this relationship is limited. Objective: To examine the changes in single-leg landing mechanics and gluteus medius recruitment that occur after a hip-abductor fatigue protocol. Design: Descriptive laboratory study. Patients or Other Participants: Twenty physically active women (age = 21.0 ± 1.3 years). Intervention(s): Participants were tested before (prefatigue) and after (postfatigue) a hip-abductor fatigue protocol consisting of repetitive side-lying hip abduction. Main Outcome Measure(s): Outcome measures included sagittal-plane and frontal-plane hip and knee kinematics at initial contact and at 60 milliseconds after initial contact during 5 single-leg landings from a height of 40 cm. Peak hip and knee sagittal-plane and frontal-plane joint moments during this time interval were also analyzed. Measures of gluteus medius activation, including latency, peak amplitude, and integrated signal, were recorded. Results: A small (<1°) increase in hip-abduction angle at initial contact and a small (<1°) decrease in knee-abduction (valgus) angle at 60 milliseconds after contact were observed in the postfatigue landing condition. No other kinematic changes were noted for the knee or hip at initial contact or at 60 milliseconds after initial contact. Peak external knee-adduction moment decreased 27% and peak hip adduction moment decreased 24% during the postfatigue landing condition. Gluteus medius activation was delayed after the protocol, but no difference in peak or integrated signal was seen during the landing trials. Conclusions: Changes observed during single-leg landings after hip-abductor fatigue were not generally considered unfavorable to the integrity of the anterior cruciate ligament. Further work may be justified to study the role of hip-abductor activation in protecting the knee during landing. PMID:21214348
Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng
2013-07-01
To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.
HIP/PAP accelerates liver regeneration and protects against acetaminophen injury in mice.
Lieu, Hanh-Tu; Batteux, Frédéric; Simon, Marie-Thérèse; Cortes, Alexandre; Nicco, Carole; Zavala, Flora; Pauloin, Alain; Tralhao, José Guilherme; Soubrane, Olivier; Weill, Bernard; Bréchot, Christian; Christa, Laurence
2005-09-01
Human hepatocarcinoma-intestine-pancreas/pancreatic-associated protein HIP/PAP is a secreted C-type lectin belonging to group VII, according to Drickamer's classification. HIP/PAP is overexpressed in liver carcinoma; however, its functional role remains unclear. In this study, we demonstrate that HIP/PAP is a paracrine hepatic growth factor promoting both proliferation and viability of liver cells in vivo. First, a low number of implanted hepatocytes deriving from HIP/PAP-transgenic mice (<1:1,000) was sufficient to stimulate overall recipient severe combined immunodeficiency liver regeneration after partial hepatectomy. After a single injection of HIP/PAP protein, the percentages of bromodeoxyuridine-positive nuclei and mitosis were statistically higher than after saline injection, indicating that HIP/PAP acts as a paracrine mitogenic growth factor for the liver. Comparison of the early events posthepatectomy in control and transgenic mice indicated that HIP/PAP accelerates the accumulation/degradation of nuclear phospho-signal transducer activator transcription factor 3 and tumor necrosis factor alpha level, thus reflecting that HIP/PAP accelerates liver regeneration. Second, we showed that 80% of the HIP/PAP-transgenic mice versus 25% of the control mice were protected against lethal acetaminophen-induced fulminate hepatitis. A single injection of recombinant HIP/PAP induced a similar cytoprotective effect, demonstrating the antiapoptotic effect of HIP/PAP. Comparison of Cu/Zn superoxide dismutase activity and glutathione reductase-like effects in control and transgenic liver mice indicated that HIP/PAP exerts an antioxidant activity and prevents reactive oxygen species-induced mitochondrial damage by acetaminophen overdose. In conclusion, the present data offer new insights into the biological functions of C-type lectins. In addition, HIP/PAP is a promising candidate for the prevention and treatment of liver failure.
Metzler, Martina; Gan, Lu; Wong, Tak Pan; Liu, Lidong; Helm, Jeffrey; Liu, Lili; Georgiou, John; Wang, Yushan; Bissada, Nagat; Cheng, Kevin; Roder, John C; Wang, Yu Tian; Hayden, Michael R
2007-02-28
Huntingtin-interacting protein 1 (HIP1) is an endocytic adaptor protein that plays a role in clathrin-mediated endocytosis and the ligand-induced internalization of AMPA receptors (AMPARs) (Metzler et al., 2003). In the present study, we investigated the role of HIP1 in NMDA receptor (NMDAR) function by analyzing NMDA-dependent transport and NMDA-induced excitotoxicity in neurons from HIP1-/- mice. HIP1 colocalizes with NMDARs in hippocampal and cortical neurons and affinity purifies with NMDARs by GST (glutathione S-transferase) pull down and coimmunoprecipitation. A profound decrease in NMDA-induced AMPAR internalization of 75% occurs in neurons from HIP1-/- mice compared with wild type, using a quantitative single-cell-based internalization assay. This defect in NMDA-dependent removal of surface AMPARs is in agreement with the observed defect in long-term depression induction in hippocampal brain slices of HIP1-/- mice and supports a role of HIP1 in AMPAR internalization in vivo. HIP1-/- neurons are partially protected from NMDA-induced excitotoxicity as assessed by LDH (lactate dehydrogenase) release, TUNEL (terminal deoxynucleotidyl transferase-mediated biotinylated dUTP nick end labeling) and caspase-3 activation assays, which points to a role of HIP1 in NMDA-induced cell death. Interestingly, phosphorylation of Akt and its substrate huntingtin (htt) decreases during NMDA-induced excitotoxicity by 48 and 31%, respectively. This decrease is significantly modulated by HIP1, resulting in 94 and 48% changes in P-Akt and P-htt levels in HIP1-/- neurons, respectively. In summary, we have shown that HIP1 influences important NMDAR functions and that both HIP1 and htt participate in NMDA-induced cell death. These findings may provide novel insights into the cellular mechanisms underlying enhanced NMDA-induced excitotoxicity in Huntington's disease.
Dynamic Hip Kinematics During the Golf Swing After Total Hip Arthroplasty.
Hara, Daisuke; Nakashima, Yasuharu; Hamai, Satoshi; Higaki, Hidehiko; Ikebe, Satoru; Shimoto, Takeshi; Yoshimoto, Kensei; Iwamoto, Yukihide
2016-07-01
Although most surgeons allow their patients to play golf after total hip arthroplasty (THA), the effect on the implant during the golf swing is still unclear. To evaluate hip kinematics during the golf swing after THA. Descriptive laboratory study. Eleven hips in 9 patients who underwent primary THA were analyzed. All patients were right-handed recreational golfers, and these 11 hips included 6 right hips and 5 left hips. Periodic radiographic images of the golf swing were taken using a flat-panel x-ray detector. Movements of the hip joint and components were assessed using 3-dimensional-to-2-dimensional model-to-image registration techniques. Liner-to-neck contact and translation of the femoral head with respect to the acetabular cup (cup-head translation) were examined. Hip kinematics, orientation of components, and maximum cup-head translation were compared between patients with and without liner-to-neck contact. On average, the golf swing produced approximately 50° of axial rotation in both lead and trail hips. Liner-to-neck contact was observed in 4 hips with elevated rim liners (2 lead hips and 2 trail hips) at maximum external rotation. Neither bone-to-bone nor bone-to-implant contact was observed at any phases of the golf swing in any of the hips. Four hips with liner-to-neck contact had significantly larger maximum external rotation (37.9° ± 7.0° vs 20.6° ± 9.9°, respectively; P = .01) and more cup anteversion (26.5° ± 6.1° vs 10.8° ± 8.9°, respectively; P = .01) than hips without liner-to-neck contact. No significant differences between hips with and without contact were found for cup inclination (42.0° ± 2.5° vs 38.1° ± 5.5°, respectively; P = .22), combined anteversion (45.3° ± 8.9° vs 51.4° ± 7.9°, respectively; P = .26), or maximum cup-head translation (1.3 ± 0.3 mm vs 1.5 ± 0.4 mm, respectively; P = .61). In this analysis, the golf swing did not produce excessive hip rotation or cup-head translation in any hips. However, liner-to-neck contact during the golf swing was observed in 36% of the hips, with unknown effects on the long-term results. Golf is an admissible sport after THA because dynamic hip stability was observed. However, the implant position, especially cup anteversion and the use of elevated rim liners, promoted liner-to-neck contact. © 2016 The Author(s).