Science.gov

Sample records for home air quality

  1. Indoor air quality in Latino homes in Boulder, Colorado

    NASA Astrophysics Data System (ADS)

    Escobedo, Luis E.; Champion, Wyatt M.; Li, Ning; Montoya, Lupita D.

    2014-08-01

    Indoor concentrations of airborne pollutants can be several times higher than those found outdoors, often due to poor ventilation, overcrowding, and the contribution of indoor sources within a home. Americans spend most of their time indoors where exposure to poor indoor air quality (IAQ) can result in diminished respiratory and cardiovascular health. This study measured the indoor air quality in 30 homes of a low-income Latino community in Boulder, Colorado during the summer of 2012. Participants were administered a survey, which included questions on their health conditions and indoor air pollution sources like cigarette smoke, heating fuel, and building materials. Twenty-four hour samples of fine particulate matter (PM2.5) from the indoor air were collected in each home; ambient PM2.5 samples were collected each day as well. Concurrent air samples were collected onto 47 mm Teflo and Tissuquartz filter at each location. Teflo filters were analyzed gravimetrically to measure PM2.5 and their extracts were used to determine levels of proteins and endotoxins in the fine fraction. The Tissuquartz filters were analyzed for elemental and organic carbon content (EC/OC). Results indicated that the indoor air contained higher concentrations of PM2.5 than the ambient air, and that the levels of OC were much higher than EC in both indoor and outdoor samples. This community showed no smoking in their homes and kept furry pets indoors at very low rates; therefore, cooking is likely the primary source of indoor PM. For responders with significant exposure to PM, it appeared to be primarily from occupational environments or childhood exposure abroad. Our findings indicate that for immigrant communities such as this, it is important to consider not only their housing conditions but also the relevant prior exposures when conducting health assessments.

  2. Impacts of Mixing on Acceptable Indoor Air Quality in Homes

    SciTech Connect

    Sherman, Max H.; Walker, Iain I.

    2010-01-01

    Ventilation reduces occupant exposure to indoor contaminants by diluting or removing them. In a multi-zone environment such as a house, every zone will have different dilution rates and contaminant source strengths. The total ventilation rate is the most important factor in determining occupant exposure to given contaminant sources, but the zone-specific distribution of exhaust and supply air and the mixing of ventilation air can play significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage, air distribution system, and contaminant source and occupant locations. Most U.S. and Canadian homes have central heating, ventilation, and air conditioning systems, which tend to mix the air; thus, the indoor air in different zones tends to be well mixed for significant fractions of the year. This article reports recent results of investigations to determine the impact of air mixing on exposures of residential occupants to prototypical contaminants of concern. We summarize existing literature and extend past analyses to determine the parameters than affect air mixing as well as the impacts of mixing on occupant exposure, and to draw conclusions that are relevant for standards development and for practitioners designing and installing home ventilation systems. The primary conclusion is that mixing will not substantially affect the mean indoor air quality across a broad population of occupants, homes, and ventilation systems, but it can reduce the number of occupants who are exposed to extreme pollutant levels. If the policy objective is to minimize the number of people exposed above a given pollutant threshold, some amount of mixing will be of net benefit even though it does not benefit average exposure. If the policy is to minimize exposure on average, then mixing air in homes is detrimental and should not be encouraged. We also conclude that most homes in the US have adequate mixing

  3. Air quality in tightly sealed and passive homes

    SciTech Connect

    Scott, L.A.

    1981-09-01

    Indoor air quality has attracted increasing attention during the past few yars. Pollutants generated from combustion, building materials, and human activities may reach significant levels in the indoor environment to produce adverse health effects. This report deals with the classes of pollutants and their sources, and the significance of reported levels, possible health effects, and control strategies in relation to tightly sealed and passive solar construction techniques. In tightly sealed homes, residential air-to-air heat exchangers, whose design and performance are discussed, offer one method of improving air quality at reasonable cost. It is recommended that further research be implemented to identify hazardous concentrations of pollutants and set standards to minimize health impacts in the search for new energy innovations.

  4. Ventilation, indoor air quality, and health in homes undergoing weatherization.

    PubMed

    Francisco, P W; Jacobs, D E; Targos, L; Dixon, S L; Breysse, J; Rose, W; Cali, S

    2017-03-01

    Ventilation standards, health, and indoor air quality have not been adequately examined for residential weatherization. This randomized trial showed how ASHRAE 62-1989 (n=39 houses) and ASHRAE 62.2-2010 (n=42 houses) influenced ventilation rates, moisture balance, indoor air quality, and self-reported physical and mental health outcomes. Average total airflow was nearly twice as high for ASHRAE 62.2-2010 (79 vs. 39 cfm). Volatile organic compounds, formaldehyde and carbon dioxide were all significantly reduced for the newer standard and first-floor radon was marginally lower, but for the older standard, only formaldehyde significantly decreased. Humidity in the ASHRAE 62.2-2010 group was only about half that of the ASHRAE 62-1989 group using the moisture balance metric. Radon was higher in the basement but lower on the first floor for ASHRAE 62.2-2010. Children in each group had fewer headaches, eczema, and skin allergies after weatherization and adults had improvements in psychological distress. Indoor air quality and health improve when weatherization is accompanied by an ASHRAE residential ventilation standard, and the 2010 ASHRAE standard has greater improvements in certain outcomes compared to the 1989 standard. Weatherization, home repair, and energy conservation projects should use the newer ASHRAE standard to improve indoor air quality and health. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Weatherization and Indoor Air Quality: Measured Impacts in Single Family Homes Under the Weatherization Assistance Program

    SciTech Connect

    Pigg, Scott; Cautley, Dan; Francisco, Paul; Hawkins, Beth A; Brennan, Terry M

    2014-09-01

    This report summarizes findings from a national field study of indoor air quality parameters in homes treated under the Weatherization Assistance Program (WAP). The study involved testing and monitoring in 514 single-family homes (including mobile homes) located in 35 states and served by 88 local weatherization agencies.

  6. Indoor air quality study of forty east Tennessee homes

    SciTech Connect

    Hawthorne, A.R.; Gammage, R.B.; Dudney, C.S.; Hingerty, B.E.; Schuresko, D.D.; Parzyck, D.C.; Womack, D.R.; Morris, S.A.; Westley, R.R.; White, D.A.

    1984-12-01

    Over a one-year period, measurements of indoor air pollutants (CO/sub x/, NO/sub x/, formaldehyde, volatile organics, particulates, and radon) were made in 40 homes in East Tennessee. The houses were of various ages with different types of insulation and heating. Over one-half of the houses exceeded the ASHRAE indoor ceiling guideline of 0.1 ppM for formaldehyde on at least one occasion. Over the duration of the study, older houses averaged 0.04 ppM of formaldehyde while houses less than 5 years old averaged 0.08 ppM (P < 0.01). The highest concentration of formaldehyde measured was 0.4 ppM in a new home. Diurnal and seasonal fluctuations in levels of formaldehyde in some homes were as much as twofold and tenfold, respectively. The highest levels of formaldehyde were usually recorded during summer months. The concentration in indoor air of various organics was at least tenfold higher than in outdoor air. Carbon monoxide and nitrgen oxides were usually <2 and <0.02 ppM, respectively, except when gas stoves or kerosene space heaters were operating, or when a car was running in the garage. In 30% of the houses, the annual indoor guideline for radon, 4 pCi/L, was exceeded. The mean radon level in houses built on the ridgelines was 4.4 pCi/L, while houses located in the valleys had a mean level of 1.7 pCi/L (P < 0.01). The factor having the most impact on infiltration was operation of the central duct fan of the heating, ventilation, and air conditioning system. The mean rate of air exchange increased from 0.39 to 0.74 h/sup -1/ when the duct fan was operated (measurements prior to December 1982). This report presents the study design and implementation, describes the monitoring protocols, and provides a complete set of the data collected during the project. 25 references, 29 figures, 42 tables.

  7. Indoor Air Quality in 24 California Residences Designed as High-Performance Homes

    SciTech Connect

    Less, Brennan; Mullen, Nasim; Singer, Brett; Walker, Iain

    2015-07-01

    Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California.

  8. Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes

    SciTech Connect

    Engelmann, P.; Roth, K.; Tiefenbeck, V.

    2013-01-01

    This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).

  9. Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes

    SciTech Connect

    Englemann, P.; Roth, K.; Tiefenbeck, V.

    2013-01-01

    This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).

  10. Measuring Infiltration Rates in Homes as a Basis for Understanding Indoor Air Quality

    NASA Astrophysics Data System (ADS)

    Jerz, G. G.; Lamb, B. K.; Pressley, S. N.; O'Keeffe, P.; Fuchs, M.; Kirk, M.

    2015-12-01

    Infiltration rates, or the rate of air exchange, of houses are important to understand because ventilation can be a dominate factor in determining indoor air quality. There are chemicals that are emitted from surfaces or point sources inside the home which are harmful to humans; these chemicals come from various objects including furniture, cleaning supplies, building materials, gas stoves, and the surrounding environment. The use of proper ventilation to cycle cleaner outdoor air into the house can be crucial for maintaining healthy living conditions in the home. At the same time, there can also be outdoor pollutants which infiltrate the house and contribute to poor indoor air quality. In either case, it is important to determine infiltration rates as a function of outdoor weather conditions, the house structure properties and indoor heating and cooling systems. In this work, the objective is to measure ventilation rates using periodic releases of a tracer gas and measuring how quickly the tracer concentration decays. CO2 will be used as the tracer gas because it is inert and harmless at low levels. An Arduino timer is connected to a release valve which controls the release of 9.00 SLPM of CO2 into the uptake vent within the test home. CO2 will be released until there is at least a 200 to 300 ppm increase above ambient indoor levels. Computers with CO2 sensors and temperature/pressure sensors attached will be used to record data from different locations within the home which will continuously record data up to a week. The results from these periodic ventilation measurements will be analyzed with respect to outdoor wind and temperature conditions and house structure properties. The data will be used to evaluate an established indoor air quality model.

  11. Indoor air quality in 24 California residences designed as high-performance homes

    SciTech Connect

    Less, Brennan; Mullen, Nasim; Singer, Brett; Walker, Iain

    2015-01-01

    Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH50, n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr-1, n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve

  12. Indoor air quality in homes of patients with chronic obstructive pulmonary disease.

    PubMed

    Osman, Liesl M; Douglas, J Graham; Garden, Carole; Reglitz, Karen; Lyon, Janice; Gordon, Sue; Ayres, Jon G

    2007-09-01

    Outdoor air quality is associated with respiratory morbidity and mortality. Less is known of the relationship of indoor air quality to respiratory health of groups vulnerable to outdoor air, such as those with chronic obstructive pulmonary disease (COPD). To investigate among patients with COPD the association of health status with indoor air quality in their homes. Observational study of indoor environmental characteristics of homes of 148 patients with severe COPD in North East Scotland. Airborne living room levels of particulate matter with a diameter of 2.5 microm or less (PM(2.5)) (microg/m(3)) were measured over 8 to 14 hours using DustTrak monitors. Nitrogen dioxide exposure (ppb) in living rooms was measured over 1 week. Endotoxin (EU [endotoxin units]/mg) in living room dust was measured. Health status of participants was assessed by the St. George's Respiratory Health Questionnaire (symptoms, activity limitation, and disease impact). The mean age of participants was 69 years. Approximately 45% were male, 39% were smokers, and 49% lived in smoking households. Average indoor PM(2.5) levels were 18 mug/m(3), nitrogen dioxide was 7.8 ppb, and endotoxin levels were 95.8 EU/mg of dust. PM(2.5) was significantly higher in smoking households (P < 0.001) and was associated with higher levels of endotoxin and NO(2). PM(2.5) was significantly associated with increased symptom burden (P < 0.01), with greater effect for current smokers. Endotoxin and nitrogen dioxide exposure were not related to health status. Higher levels of PM(2.5) are associated with worse health status of these patients with severe COPD. Indoor levels of PM(2.5) are significantly higher in homes with smokers.

  13. Children's Health and Indoor Air Quality in Primary Schools and Homes in Portugal-Study Design.

    PubMed

    Madureira, Joana; Paciência, Inês; Ramos, Elisabete; Barros, Henrique; Pereira, Cristiana; Teixeira, João Paulo; Fernandes, Eduardo de Oliveira

    2015-01-01

    The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.

  14. Indoor air quality, ventilation and respiratory health in elderly residents living in nursing homes in Europe.

    PubMed

    Bentayeb, Malek; Norback, Dan; Bednarek, Micha; Bernard, Alfred; Cai, Guihong; Cerrai, Sonia; Eleftheriou, Konstantinos Kostas; Gratziou, Christina; Holst, Gitte Juel; Lavaud, François; Nasilowski, Jacek; Sestini, Piersante; Sarno, Giuseppe; Sigsgaard, Torben; Wieslander, Gunilla; Zielinski, Jan; Viegi, Giovanni; Annesi-Maesano, Isabella

    2015-05-01

    Few data exist on respiratory effects of indoor air quality and comfort parameters in the elderly. In the context of the GERIE study, we investigated for the first time the relationships of these factors to respiratory morbidity among elderly people permanently living in nursing homes in seven European countries. 600 elderly people from 50 nursing homes underwent a medical examination and completed a standardised questionnaire. Air quality and comfort parameters were objectively assessed in situ in the nursing home. Mean concentrations of air pollutants did not exceed the existing standards. Forced expiratory volume in 1 s/forced vital capacity ratio was highly significantly related to elevated levels of particles with a 50% cut-off aerodynamic diameter of <0.1 µm (PM0.1) (adjusted OR 8.16, 95% CI 2.24-29.3) and nitrogen dioxide (aOR 3.74, 95% CI 1.06-13.1). Excess risks for usual breathlessness and cough were found with elevated PM10 (aOR 1.53 (95% CI 1.15-2.07) and aOR 1.73 (95% CI 1.17-10.3), respectively) and nitrogen dioxide (aOR 1.58 (95% CI 1.15-2.20) and aOR 1.56 (95% CI 1.03-2.41), respectively). Excess risks for wheeze in the past year were found with PM0.1 (aOR 2.82, 95% CI 1.15-7.02) and for chronic obstructive pulmonary disease and exhaled carbon monoxide with formaldehyde (aOR 3.49 (95% CI 1.17-10.3) and aOR 1.25 (95% CI 1.02-1.55), respectively). Breathlessness and cough were associated with higher carbon dioxide. Relative humidity was inversely related to wheeze in the past year and usual cough. Elderly subjects aged ≥80 years were at higher risk. Pollutant effects were more pronounced in the case of poor ventilation. Even at low levels, indoor air quality affected respiratory health in elderly people permanently living in nursing homes, with frailty increasing with age. The effects were modulated by ventilation. Copyright ©ERS 2015.

  15. Indoor air quality in 300 homes in Kingston/Harriman, Tennessee

    SciTech Connect

    Hawthorne, A.R.; Aldrich, T.E.; Vo-Dinh, T.; Uziel, M.; Cohen, M.A.; Hamilton, C.B.; Orebaugh, C.T.; Miller, G.H.; Ironsides, K.; Monar, K.P.

    1988-07-01

    Supplemental indoor air quality measurements were conducted in the Kingston/Harriman area for radon, formaldehyde, polynuclear aromatic hydrocarbons, and airborne micoorganisms. Eight groups of houses were chosen based on the presence or absence of the following sources: cigarette smoking, woodstoves, and kerosene heaters. Core measurements were made for a two/endash/week period in each house during the winter season again during the summer season. In addition, both vapor phase and particulate phase polynuclear aromatic hydrocarbons were monitored. Viable airborne bacteria and fungi were also sampled in a large subset of houses. Detailed energy use/weatherization surveys were conducted in 120 homes by utility trained auditors. Preliminary results indicate that mean winter radon levels were 2.4 pCi/L and mean summer radon levels were 1.3 pCi/L (excluding basement measurements). Mean formaldehyde levels were 0. 0444 ppm in winter and 0.065 ppm in summer. Polynuclear aromatic compounds were higher in homes with smokers, with levels positively related to the reported consumption of cigarettes. Higher levels of airborne bacteria and fungi were found indoors than outdoors, with approximately 50/percent/ of the homes exhibiting concentrations greater than 1000 CFU/m/sup 3/. 51 figs., 81 tabs.

  16. Investigation of indoor air quality at residential homes in Hong Kong—case study

    NASA Astrophysics Data System (ADS)

    Lee, Shun Cheng; Li, Wai-Ming; Ao, Chio-Hang

    Indoor air quality (IAQ) has been a matter of public concern in Hong Kong. Recently, the Hong Kong Government has recognized the potential risk and problems related to indoor air pollution, and it is striving to establish IAQ objectives for different types of indoor environments. This study attempts to provide more information about the present IAQ of local resident flats. Air pollutants measured in this study included carbon dioxide (CO 2), respirable suspended particulate matter (PM 10), formaldehyde (HCHO), volatile organic compounds (VOCs) and airborne bacteria. The results of this study indicate that the 8-h average concentrations of CO 2 and PM 10 in the domestic kitchens investigated were 14% and 67% higher than those measured in the living rooms. The indoor air pollution caused by PM 10 was more serious in domestic kitchens than in living rooms as almost all of the kitchens investigated had higher indoor levels of PM 10. The majority of the domestic living rooms and kitchens studied had average concentrations of airborne bacteria higher than 500 CFU/m 3. The mean total bacteria count recorded in kitchens was greater than that obtained in living rooms by 23%. In homes where occupants smoke, the negative impact of benzene, toluene and m, p-xylene on the IAQ was greatly enhanced. The use of liquefied petroleum gas (LPG) stove has more significant impact on indoor VOCs than the use of cooking stoves with natural gas as cooking fuel.

  17. Optimization of Ventilation Energy Demands and Indoor Air Quality in the ZEBRAlliance Homes

    SciTech Connect

    Hun, D.; Jackson, M.; Shrestha, S.

    2013-09-01

    High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. In this project, Oak Ridge National Laboratory researchers attempted to bridge these two areas by conducting tests in research houses located in Oak Ridge, TN, that were less than 2 years old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built, unoccupied, and unfurnished. The team identified air pollutants of concern in the test homes that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern from initial air sampling surveys. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74°F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused minimal to modest increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

  18. Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes

    SciTech Connect

    Hun, Diana E; Jackson, Mark C; Shrestha, Som S

    2014-01-01

    High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

  19. Results of the California Healthy Homes Indoor Air Quality Study of 2011-2013: impact of natural gas appliances on air pollutant concentrations.

    PubMed

    Mullen, N A; Li, J; Russell, M L; Spears, M; Less, B D; Singer, B C

    2016-04-01

    This study was conducted to assess the current impact of natural gas appliances on air quality in California homes. Data were collected via telephone interviews and measurements inside and outside of 352 homes. Passive samplers measured time-resolved CO and time-integrated NOX , NO2 , formaldehyde, and acetaldehyde over ~6-day periods in November 2011 - April 2012 and October 2012 - March 2013. The fraction of indoor NOX and NO2 attributable to indoor sources was estimated. NOX , NO2 , and highest 1-h CO were higher in homes that cooked with gas and increased with amount of gas cooking. NOX and NO2 were higher in homes with cooktop pilot burners, relative to gas cooking without pilots. Homes with a pilot burner on a floor or wall furnace had higher kitchen and bedroom NOX and NO2 compared to homes without a furnace pilot. When scaled to account for varying home size and mixing volume, indoor-attributed bedroom and kitchen NOX and kitchen NO2 were not higher in homes with wall or floor furnace pilot burners, although bedroom NO2 was higher. In homes that cooked 4 h or more with gas, self-reported use of kitchen exhaust was associated with lower NOX , NO2 , and highest 1-h CO. Gas appliances were not associated with higher concentrations of formaldehyde or acetaldehyde. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Results of the California Healthy Homes Indoor Air Quality Study of 2011-2013: Impact of natural gas appliances on air pollutant concentrations

    DOE PAGES

    Mullen, Nasim A.; Li, Jina; Russell, Marion L.; ...

    2015-03-17

    This study was conducted to assess the current impact of natural gas appliances on air quality in California homes. Data were collected via telephone interviews and measurements inside and outside of 352 homes. Passive samplers measured time-resolved CO and time-integrated NOX, NO2, formaldehyde, and acetaldehyde over ~6d periods in November 2011 - April 2012 and October 2012 - March 2013. The fraction of indoor NOX and NO2 attributable to indoor sources was estimated. NOX, NO2 and highest 1-h CO were higher in homes that cooked with gas and increased with amount of gas cooking. NOX and NO2 were higher inmore » homes with cooktop pilot burners, relative to gas cooking without pilots. Homes with a pilot burner on a floor or wall furnace had higher kitchen and bedroom NOX and NO2 compared to homes without a furnace pilot. When scaled to account for varying home size and mixing volume, indoor-attributed bedroom and kitchen NOX and kitchen NO2 were not higher in homes with wall or floor furnace pilot burners, though bedroom NO2 was higher. In homes that cooked 4 h or more with gas, self-reported use of kitchen exhaust was associated with lower NOX, NO2 and highest 1-h CO. Gas appliances were not associated with higher concentrations of formaldehyde or acetaldehyde.« less

  1. Associations between Parents' Perceived Air Quality in Homes and Health among Children in Nanjing, China.

    PubMed

    Qian, Hua; Zheng, Xiaohong; Zhang, Min; Weschler, Louise; Sundell, Jan

    2016-01-01

    The increasing prevalence of respiratory diseases in Chinese children has focused attention on indoor environmental quality. We investigated associations between perceived air quality in domestic environments and children's allergic diseases with a questionnaire survey study. A total of 4017 children aged 1-8 years old from 23 kindergartens in urban, suburban and industrial areas in Nanjing were randomly recruited for this study. Parents' perceived odors, including stuffy odor, unpleasant odor, pungent odor, moldy odor, humid air and dry air were found to be associated with asthma, wheeze, dry cough and rhinitis (P < 0.05). Both perceived dry and humid air were found to be positively associated with dampness indices, and we present evidence that the sensation of dryness may not be due to the actual indoor relative humidity, but rather to indoor air irritants. Parents' perception of odors and relative humidity may be indicators of environment pollutants, which are likely the real factors associated with children's allergic diseases.

  2. Using a new, low-cost air quality sensor to quantify second-hand smoke (SHS) levels in homes.

    PubMed

    Semple, Sean; Ibrahim, Azmina Engku; Apsley, Andrew; Steiner, Markus; Turner, Stephen

    2015-03-01

    To determine if a low-cost particle counter, the Dylos DC 1700, can be used in homes to quantify second-hand smoke (SHS) concentrations. Participants were recruited from a hospital-based study of attitudes on smoking. Two photometric devices (Dylos DC1700 and Sidepak AM510 Personal Aerosol Monitor) capable of measuring and logging concentrations of particulate matter were placed in smoking and non-smoking homes for approximately 24h. Acquired data were randomly allocated to one of two groups: one was used to generate a calibration equation using regression techniques; the second was used for validation of the generated model. The mean difference and limits of agreement between the two instruments were calculated using the validation dataset. Summary air-quality results were also compared across the entire dataset. Over 500 001 minute concentration measurements were collected from 34 homes. 25 301 randomly selected paired-measurements were used to generate a calibration equation (R(2) 0.86) converting the particle number concentration from the Dylos to a mass concentration of PM2.5 as measured by the Sidepak. The mean difference (limits of agreement) between the remaining 25 102 paired measurements was -0.09 (-49.7 to 49.5) with 3.2% of values outside the limits of agreement. Differences in the air quality information generated by the two instruments were generally small and unlikely to impact on user interpretation. The Dylos appears to be a valid instrument for measuring PM2.5 in household settings. The Dylos may be useful in air quality-based interventions designed to change smokers' behaviours with the possibility of encouraging cessation and/or smoke-free homes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Engineering Strategies and Methods for Avoiding Air-Quality Externalities: Dispersion Modeling, Home Energy Conservation, and Scenario Planning

    NASA Astrophysics Data System (ADS)

    Knox, Andrew James

    Energy conservation can improve air quality by reducing emissions from fuel combustion. The human health value retained through better air quality can then offset the cost of energy conservation. Through this thesis' innovative yet widely-accessible combination of air pollution dispersion modeling and atmospheric chemistry, it is estimated that the health value retained by avoiding emissions from Ontario's former coal-fired generating stations is 5.74/MWh (using an upper-bound value of 265,000 per year of life lost). This value is combined with energy modeling of homes in the first-ever assessment of the air-quality health benefits of low-energy buildings. It is shown that avoided health damages can equal 7% of additional construction costs of energy efficient buildings in Ontario. At 7%, health savings are a significant item in the cost analysis of efficient buildings. Looking to energy efficiency in the context of likely future low-resource natural gas scenarios, building efficient buildings today is shown to be more economically efficient than any building retrofit option. Considering future natural gas scarcity in the context of Ontario's Long-Term Energy Plan reveals that Ontario may be forced to return to coal-fired electricity. Projected coal use would result in externalities greater than $600 million/year; 80% more than air-quality externalities from Ontario's electricity in 1985. Radically aggressive investment in electricity conservation (75% reduction per capita by 2075) is one promising path forward that keeps air-quality externalities below 1985 levels. Non-health externalities are an additional concern, the quantification, and ultimately monetization, of which could be practical using emerging air pollution monitoring technologies. Energy, conservation, energy planning, and energy's externalities form a complex situation in which today's decisions are critical to a successful future. It is clear that reducing the demand for energy is essential and

  4. Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships

    NASA Astrophysics Data System (ADS)

    Baek, Sung-Ok; Kim, Yoon-Shin; Perry, Roger

    Air quality monitoring was carried out to collect data on the levels of various indoor and ambient air constituents in two cities in Korea (Seoul and Taegu). Sampling was conducted simultaneously indoors and outdoors at six residences, six offices and six restaurants in each city during summer 1994 and winter 1994-1995. Measured pollutants were respirable suspended particulate matter (RSP), carbon monoxide (CO), carbon dioxide (CO 2), nitrogen dioxide (NO 2), and a range of volatile organic compounds (VOCs). In addition, in order to evaluate the effect of smoking on indoor air quality, analyses of parameters associated with environmental tobacco smoke (ETS) were undertaken, which are nicotine, ultraviolet (UVPM), fluorescence (FPM) and solanesol particulate matter (SolPM). The results of this study have confirmed the importance of ambient air in determining the quality of air indoors in two major Korean cities. The majority of VOCs measured in both indoor and outdoor environments were derived from outdoor sources, probably motor vehicles. Benzene and other VOC concentrations were much higher during the winter months than the summer months and were not significantly greater in the smoking sites examined. Heating and cooking practices, coupled with generally inadequate ventilation, also were shown to influence indoor air quality. In smoking sites, ETS appears to be a minor contributor to VOC levels as no statistically significant relationships were identified with ETS components and VOCs, whereas very strong correlations were found between indoor and outdoor levels of vehicle-related pollutants. The average contribution of ETS to total RSP concentrations was estimated to range from 10 to 20%.

  5. Associations between Parents’ Perceived Air Quality in Homes and Health among Children in Nanjing, China

    PubMed Central

    Qian, Hua; Zheng, Xiaohong; Zhang, Min; Weschler, Louise; Sundell, Jan

    2016-01-01

    The increasing prevalence of respiratory diseases in Chinese children has focused attention on indoor environmental quality. We investigated associations between perceived air quality in domestic environments and children’s allergic diseases with a questionnaire survey study. A total of 4017 children aged 1–8 years old from 23 kindergartens in urban, suburban and industrial areas in Nanjing were randomly recruited for this study. Parents’ perceived odors, including stuffy odor, unpleasant odor, pungent odor, moldy odor, humid air and dry air were found to be associated with asthma, wheeze, dry cough and rhinitis (P < 0.05). Both perceived dry and humid air were found to be positively associated with dampness indices, and we present evidence that the sensation of dryness may not be due to the actual indoor relative humidity, but rather to indoor air irritants. Parents’ perception of odors and relative humidity may be indicators of environment pollutants, which are likely the real factors associated with children’s allergic diseases. PMID:27191186

  6. Comparison of air pollutant emissions and household air quality in rural homes using improved wood and coal stoves

    NASA Astrophysics Data System (ADS)

    Du, Wei; Shen, Guofeng; Chen, Yuanchen; Zhu, Xi; Zhuo, Shaojie; Zhong, Qirui; Qi, Meng; Xue, Chunyu; Liu, Guangqing; Zeng, Eddy; Xing, Baoshan; Tao, Shu

    2017-10-01

    Air pollutant emissions, fuel consumption, and household air pollution were investigated in rural Hubei, central China, as a revisited evaluation of an intervention program to replace coal use by wood in gasifier stoves. Measured emission factors were comparable to the results measured two years ago when the program was initiated. Coal combustion produced significantly higher emissions of CO2, CH4, and SO2 compared with wood combustion; however, wood combustion in gasifier stoves had higher emissions of primary PM2.5 (particles with diameter less than 2.5 μm), Elemental Carbon (EC) and Organic Carbon (OC). In terms of potential impacts on climate, although the use of wood in gasifier stoves produced more black carbon (6.37 vs 910 gCO2e per day per capita from coal and wood use) and less SO2 (-684 vs -312), obvious benefits could be obtained owing to greater OC emissions (-15.4 vs -431), fewer CH4 emissions (865 vs 409) and, moreover, a reduction of CO2 emissions. The total GWC100 (Global Warming Potential over a time horizon of 100 years) would decrease by approximately 90% if coal use were replaced with renewable wood burned in gasifier stoves. However, similar levels of ambient particles and higher indoor OC and EC were found at homes using wood gasifier stoves compared to the coal-use homes. This suggests critical investigations on potential health impacts from the carbon-reduction intervention program.

  7. Results of the California Healthy Homes Indoor Air Quality Study of 2011-2013: Impact of natural gas appliances on air pollutant concentrations

    SciTech Connect

    Mullen, Nasim A.; Li, Jina; Russell, Marion L.; Spears, Michael; Less, Brennan D.; Singer, Brett C.

    2015-03-17

    This study was conducted to assess the current impact of natural gas appliances on air quality in California homes. Data were collected via telephone interviews and measurements inside and outside of 352 homes. Passive samplers measured time-resolved CO and time-integrated NOX, NO2, formaldehyde, and acetaldehyde over ~6d periods in November 2011 - April 2012 and October 2012 - March 2013. The fraction of indoor NOX and NO2 attributable to indoor sources was estimated. NOX, NO2 and highest 1-h CO were higher in homes that cooked with gas and increased with amount of gas cooking. NOX and NO2 were higher in homes with cooktop pilot burners, relative to gas cooking without pilots. Homes with a pilot burner on a floor or wall furnace had higher kitchen and bedroom NOX and NO2 compared to homes without a furnace pilot. When scaled to account for varying home size and mixing volume, indoor-attributed bedroom and kitchen NOX and kitchen NO2 were not higher in homes with wall or floor furnace pilot burners, though bedroom NO2 was higher. In homes that cooked 4 h or more with gas, self-reported use of kitchen exhaust was associated with lower NOX, NO2 and highest 1-h CO. Gas appliances were not associated with higher concentrations of formaldehyde or acetaldehyde.

  8. Effect of gas and kerosene space heaters on indoor air quality: a study in homes of Santiago, Chile.

    PubMed

    Ruiz, Pablo A; Toro, Claudia; Cáceres, Jorge; López, Gianni; Oyola, Pedro; Koutrakis, Petros

    2010-01-01

    The impact of outdoor and indoor pollution sources on indoor air quality in Santiago, Chile was investigated. Toward this end, 16 homes were sampled in four sessions. Each session included an outdoor site and four homes using different unvented space heaters (electric or central heating, compressed natural gas, liquefied petroleum gas, and kerosene). Average outdoor fine particulate matter (PM2.5) concentrations were very high (55.9 microg x m(-3)), and a large fraction of these particles penetrated indoors. PM2.5 and several PM2.5 components (including sulfate, elemental carbon, organic carbon, metals, and polycyclic aromatic hydrocarbons) were elevated in homes using kerosene heaters. Nitrogen dioxide (NO2) and ultrafine particles (UFPs) were higher in homes with combustion heaters as compared with those with electric heaters or central heating. A regression model was used to assess the effect of heater use on continuous indoor PM2.5 concentrations when windows were closed. The model found an impact only for kerosene heaters (45.8 microg m(-3)).

  9. Air quality and acute respiratory illness in biomass fuel using homes in Bagamoyo, Tanzania.

    PubMed

    Kilabuko, James H; Matsuki, Hidieki; Nakai, Satoshi

    2007-03-01

    Respiratory Diseases are public health concern worldwide. The diseases have been associated with air pollution especially indoor air pollution from biomass fuel burning in developing countries. However, researches on pollution levels and on association of respiratory diseases with biomass fuel pollution are limited. A study was therefore undertaken to characterize the levels of pollutants in biomass fuel using homes and examine the association between biomass fuel smoke exposure and Acute Respiratory Infection (ARI) disease in Nianjema village in Bagamoyo, Tanzania. Pollution was assessed by measuring PM10, NO2, and CO concentrations in kitchen, living room and outdoors. ARI prevalence was assessed by use of questionnaire which gathered health information for all family members under the study. Results showed that PM10, NO2, and CO concentrations were highest in the kitchen and lowest outdoors. Kitchen concentrations were highest in the kitchen located in the living room for all pollutants except CO. Family size didn't have effect on the levels measured in kitchens. Overall ARI prevalence for cooks and children under age 5 making up the exposed group was 54.67% with odds ratio (OR) of 5.5; 95% CI 3.6 to 8.5 when compared with unexposed men and non-regular women cooks. Results of this study suggest an association between respiratory diseases and exposure to domestic biomass fuel smoke, but further studies with improved design are needed to confirm the association.

  10. Air Quality and Acute Respiratory Illness in Biomass Fuel using homes in Bagamoyo, Tanzania

    PubMed Central

    Kilabuko, James H.; Matsuki, Hidieki; Nakai, Satoshi

    2007-01-01

    Respiratory Diseases are public health concern worldwide. The diseases have been associated with air pollution especially indoor air pollution from biomass fuel burning in developing countries. However, researches on pollution levels and on association of respiratory diseases with biomass fuel pollution are limited. A study was therefore undertaken to characterize the levels of pollutants in biomass fuel using homes and examine the association between biomass fuel smoke exposure and Acute Respiratory Infection (ARI) disease in Nianjema village in Bagamoyo, Tanzania. Pollution was assessed by measuring PM10, NO2, and CO concentrations in kitchen, living room and outdoors. ARI prevalence was assessed by use of questionnaire which gathered health information for all family members under the study. Results showed that PM10, NO2, and CO concentrations were highest in the kitchen and lowest outdoors. Kitchen concentrations were highest in the kitchen located in the living room for all pollutants except CO. Family size didn’t have effect on the levels measured in kitchens. Overall ARI prevalence for cooks and children under age 5 making up the exposed group was 54.67% with odds ratio (OR) of 5.5; 95% CI 3.6 to 8.5 when compared with unexposed men and non-regular women cooks. Results of this study suggest an association between respiratory diseases and exposure to domestic biomass fuel smoke, but further studies with improved design are needed to confirm the association. PMID:17431314

  11. Indoor air quality and health: validity and determinants of reported home dampness and moulds.

    PubMed

    Dales, R E; Miller, D; McMullen, E

    1997-02-01

    Questionnaire-based surveys from several countries have consistently detected adverse health associated with home dampness and mould growth. To test the validity of questions commonly used to indicate the presence of indoor mould, questionnaires were administered in 403 homes where dust samples were taken for viable fungi and air samples for ergosterol. Geometric mean concentrations of the total viable fungi were 255 (SE 116) x 10(3) CFU/g when mouldy odours were reported and 155 (SE 55) when odours were not reported (P = 0.01). Similarly, reported water damage was associated with a 50% increase (P = 0.06). Geometric mean concentrations of the predominantly indoor-source fungi, Aspergillus plus Penicillium, were twice as high when mould or mildew was reported than when not mentioned (P = 0.01). The presence of reported mould or water damage was unrelated to the presence of detectable levels of ergosterol. There was evidence for reporting bias: in the presence of low concentrations of viable fungi in dust, respondents reporting allergies were more likely to report visible mould growth (odds ratio [OR] = 1.8, 95% confidence interval [CI]: 0.9-3.5, P = 0.10. In the presence of elevated concentrations of dust fungi, respondents who smoked were less likely to report visible mould growth, (OR = 0.4, 95% CI: 0.2-0.7, P = 0.005). Reported mould, water damage, and mouldy odours were associated with elevated levels of indoor fungi. However, inaccuracy was high and there was evidence of a systematic reporting bias. Future research should concentrate on developing accurate objective measures of exposure to fungi, and then use this information to develop valid questionnaires. Currently, objective measures not questionnaires, are recommended to clarify the health effects of indoor fungi.

  12. Participant Assisted Data Collection Methods in the California Healthy Homes Indoor Air Quality Study of 2011-13

    SciTech Connect

    Mullen, Nasim A.; Li, Jina; Singer, Brett C.

    2013-08-01

    From November 2011 to March 2013, air quality was measured over 6-day periods in 324 residences across California using a mail-out strategy. All interactions with study participants, from recruitment, to data collection, to communication of results, were conducted with remote communication methods including conventional mail, electronic mail, telephone and text messaging. Potential participants were reached primarily by sharing study information with community groups and organizations that directed interested individuals to complete an online screening survey. Pollutant concentrations were measured with sampling equipment that was mailed to participants' homes with deployment instructions. Residence and household characteristics and activity data were collected via two phone surveys and an activity log. A comparison of responses to survey questions completed online versus over the phone indicated that a substantial fraction of participants (roughly 20%) required a researcher's assistance to respond to basic questions about appliance characteristics. Using the printed instructions and telephone assistance from researchers, roughly 90% of participants successfully deployed and returned sampling materials accurately and on schedule. The mail-out strategy employed in this study was found to be a cost-effective means for collecting residential air quality data.

  13. Issue Backgrounder : Energy Efficient New Homes and Indoor Air Pollutants.

    SciTech Connect

    United States. Bonneville Power Administration.

    1985-07-01

    This booklet discusses what indoor air pollution is and how it can affect your health. It describes how energy-efficient new homes can affect indoor air quality. It also describes features that can help ensure clean indoor air, and tells how to detect and control indoor pollutants commonly found in homes.

  14. Quality Assurance in Nursing Homes.

    ERIC Educational Resources Information Center

    Balgopal, Pallassana R.; And Others

    This manual, developed for the nursing home employee, examines the concept of quality assurance in nursing homes, describes the benefits of an effective quality assurance program, and provides guidelines to aid nursing homes in developing an appropriate quality assurance program. After a brief introduction, a working definition of quality…

  15. Indoor air quality in green-renovated vs. non-green low-income homes of children living in a temperate region of US (Ohio).

    PubMed

    Coombs, Kanistha C; Chew, Ginger L; Schaffer, Christopher; Ryan, Patrick H; Brokamp, Cole; Grinshpun, Sergey A; Adamkiewicz, Gary; Chillrud, Steve; Hedman, Curtis; Colton, Meryl; Ross, Jamie; Reponen, Tiina

    2016-06-01

    Green eco-friendly housing includes approaches to reduce indoor air pollutant sources and to increase energy efficiency. Although sealing/tightening buildings can save energy and reduce the penetration of outdoor pollutants, an adverse outcome can be increased buildup of pollutants with indoor sources. The objective of this study was to determine the differences in the indoor air quality (IAQ) between green and non-green homes in low-income housing complexes. In one housing complex, apartments were renovated using green principles (n=28). Home visits were conducted immediately after the renovation, and subsequently at 6 months and at 12 months following the renovation. Of these homes, eight homes had pre-renovation home visits; this allowed pre- and post-renovation comparisons within the same homes. Parallel visits were conducted in non-green (control) apartments (n=14) in a nearby low-income housing complex. The IAQ assessments included PM2.5, black carbon, ultrafine particles, sulfur, total volatile organic compounds (VOCs), formaldehyde, and air exchange rate. Data were analyzed using linear mixed-effects models. None of the indoor pollutant concentrations were significantly different between green and non-green homes. However, we found differences when comparing the concentrations before and after renovation. Measured immediately after renovation, indoor black carbon concentrations were significantly lower averaging 682 ng/m(3) in post-renovation vs. 2364 ng/m(3) in pre-renovation home visits (p=0.01). In contrast, formaldehyde concentrations were significantly higher in post-renovated (0.03 ppm) than in pre-renovated homes (0.01 ppm) (p=0.004). Questionnaire data showed that opening of windows occurred less frequently in homes immediately post-renovation compared to pre-renovation; this factor likely affected the levels of indoor black carbon (from outdoor sources) and formaldehyde (from indoor sources) more than the renovation status itself. To reduce IAQ

  16. Air Quality System (AQS)

    EPA Pesticide Factsheets

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  17. Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes

    SciTech Connect

    Widder, Sarah H.; Chamness, Michele A.; Petersen, Joseph M.; Singer, Brett C.; Maddalena, Randy L.; Destaillats, Hugo; Russell, M. L.

    2014-10-01

    To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low

  18. The IVAIRE project--a randomized controlled study of the impact of ventilation on indoor air quality and the respiratory symptoms of asthmatic children in single family homes.

    PubMed

    Lajoie, P; Aubin, D; Gingras, V; Daigneault, P; Ducharme, F; Gauvin, D; Fugler, D; Leclerc, J-M; Won, D; Courteau, M; Gingras, S; Héroux, M-È; Yang, W; Schleibinger, H

    2015-12-01

    A randomized controlled trial was carried out to measure the impact of an intervention on ventilation, indoor air contaminants, and asthma symptoms of children. Eighty-three asthmatic children living in low-ventilated homes were followed over 2 years. Several environmental parameters were measured during the summer, fall, and winter. The children were randomized after Year 1 (43 Intervention; 40 Control). The intervention included the installation of either a Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV). During the fall and winter seasons, there was a significant increase in the mean ventilation rate in the homes of the intervention group. A statistically significant reduction in mean formaldehyde, airborne mold spores, toluene, styrene, limonene, and α-pinene concentrations was observed in the intervention group. There was no significant group difference in change in the number of days with symptoms per 14 days. However, there was a significant decrease in the proportion of children who experienced any wheezing (≥1 episode) and those with ≥4 episodes in the 12-month period in the intervention group. This study indicates that improved ventilation reduces air contaminants and may prevent wheezing. Due to lack of power, a bigger study is needed. Positive findings from this study include the fact that, upon recruitment, most of the single family homes with asthmatic children were already equipped with a mechanical ventilation system and had relatively good indoor air quality. However, the 8-h indoor guideline for formaldehyde (50 μg/m3) was frequently exceeded and the ventilation rates were low in most of the homes, even those with a ventilation system. Both ERVs and HRVs were equally effective at increasing air exchange rates above 0.30 ACH and at preventing formaldehyde concentrations from exceeding the 50 μg/m3 guideline during the fall and winter seasons. Furthermore, the ERVs were effective at preventing excessively low relative

  19. Fine particles in homes of predominantly low-income families with children and smokers: Key physical and behavioral determinants to inform indoor-air-quality interventions

    PubMed Central

    Bellettiere, John; Hughes, Suzanne C.; Nguyen, Benjamin; Berardi, Vincent; Liles, Sandy; Obayashi, Saori; Hofstetter, C. Richard; Blumberg, Elaine; Hovell, Melbourne F.

    2017-01-01

    Children are at risk for adverse health outcomes from occupant-controllable indoor airborne contaminants in their homes. Data are needed to design residential interventions for reducing low-income children's pollutant exposure. Using customized air quality monitors, we continuously measured fine particle counts (0.5 to 2.5 microns) over a week in living areas of predominantly low-income households in San Diego, California, with at least one child (under age 14) and at least one cigarette smoker. We performed retrospective interviews on home characteristics, and particle source and ventilation activities occurring during the week of monitoring. We explored the relationship between weekly mean particle counts and interview responses using graphical visualization and multivariable linear regression (base sample n = 262; complete cases n = 193). We found associations of higher weekly mean particle counts with reports of indoor smoking of cigarettes or marijuana, as well as with frying food, using candles or incense, and house cleaning. Lower particle levels were associated with larger homes. We did not observe an association between lower mean particle counts and reports of opening windows, using kitchen exhaust fans, or other ventilation activities. Our findings about sources of fine airborne particles and their mitigation can inform future studies that investigate more effective feedback on residential indoor-air-quality and better strategies for reducing occupant exposures. PMID:28545099

  20. Fine particles in homes of predominantly low-income families with children and smokers: Key physical and behavioral determinants to inform indoor-air-quality interventions.

    PubMed

    Klepeis, Neil E; Bellettiere, John; Hughes, Suzanne C; Nguyen, Benjamin; Berardi, Vincent; Liles, Sandy; Obayashi, Saori; Hofstetter, C Richard; Blumberg, Elaine; Hovell, Melbourne F

    2017-01-01

    Children are at risk for adverse health outcomes from occupant-controllable indoor airborne contaminants in their homes. Data are needed to design residential interventions for reducing low-income children's pollutant exposure. Using customized air quality monitors, we continuously measured fine particle counts (0.5 to 2.5 microns) over a week in living areas of predominantly low-income households in San Diego, California, with at least one child (under age 14) and at least one cigarette smoker. We performed retrospective interviews on home characteristics, and particle source and ventilation activities occurring during the week of monitoring. We explored the relationship between weekly mean particle counts and interview responses using graphical visualization and multivariable linear regression (base sample n = 262; complete cases n = 193). We found associations of higher weekly mean particle counts with reports of indoor smoking of cigarettes or marijuana, as well as with frying food, using candles or incense, and house cleaning. Lower particle levels were associated with larger homes. We did not observe an association between lower mean particle counts and reports of opening windows, using kitchen exhaust fans, or other ventilation activities. Our findings about sources of fine airborne particles and their mitigation can inform future studies that investigate more effective feedback on residential indoor-air-quality and better strategies for reducing occupant exposures.

  1. A Fleet of Low-Cost Sensor Based Air Quality Monitors Is Used to Measure Carbon Dioxide and Carbon Monoxide in Two Settings: In the Ambient Environment to Explore the Regional-Scale Spatial Variability of These Compounds Via a Distributed Network, and in Homes to Investigate How Heating during Winter Months can Impact Indoor Air Quality.

    NASA Astrophysics Data System (ADS)

    Casey, J. G.; Hannigan, M.; Collier, A. M.; Coffey, E.; Piedrahita, R.

    2016-12-01

    Affordable, small, portable, quiet tools to measure atmospheric trace gases and air quality enable novel experimental design and new findings. Members of the Hannigan Lab at the University of Colorado in Boulder have been working over the last few years to integrate emerging affordable gas sensors into such an air quality monitor. Presented here are carbon monoxide (CO) and carbon dioxide (CO2) measurements from two field experiments that utilized these tools. In the first experiment, ten air quality monitors were located northeast of Boulder throughout the Denver Julesburg oil and gas basin. The Colorado Department of Health and Environment has several air quality monitoring sites in this broader region, each in an Urban center. One goal of the experiment was to determine whether or not significant spatial variability of EPA criteria pollutants like CO, exists on a sub-regulatory monitoring grid scale. Another goal of the experiment was to compare rural sampling locations with urban sites. The monitors collected continuous data (sampling every 15 seconds) at each location over the course of several months. Our sensor calibration procedures are presented along with our observations and an analysis of the spatial and temporal variability in CO and CO2. In the second experiment, we used eight of our air quality monitors to better understand how home heating fuel type can impact indoor air quality in two communities on the Navajo Nation. We sought to compare air quality in homes using one of four different fuels for heat (wood, wood plus coal, pellet, and gas). There are many factors that contribute to indoor air quality and the impact of an emission source, like a woodstove, within a home. Having multiple, easily deployable, air quality monitors allowed us to account for many of these factors. We sampled four homes at a time, aiming for one home from each of our fuel groups in each sampling period. We sampled inside and outside of each home for a period of 3-4 days

  2. Manual on indoor air quality

    SciTech Connect

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  3. Assessment of Indoor Air Pollution in Homes with Infants

    PubMed Central

    Pickett, Anna Ruth; Bell, Michelle L.

    2011-01-01

    Infants spend most of their indoor time at home; however, residential air quality is poorly understood. We investigated the air quality of infants’ homes in the New England area of the U.S. Participants (N = 53) were parents of infants (0–6 months) who completed telephone surveys to identify potential pollutant sources in their residence. Carbon monoxide (CO), carbon dioxide (CO2), particulate matter with aerodynamic diameter ≤0.5 µm (PM0.5), and total volatile organic compounds (TVOCs) were measured in 10 homes over 4–7 days, and levels were compared with health-based guidelines. Pollutant levels varied substantially across homes and within homes with overall levels for some homes up to 20 times higher than for other homes. Average levels were 0.85 ppm, 663.2 ppm, 18.7 µg/m3, and 1626 µg/m3 for CO, CO2, PM0.5, and TVOCs, respectively. CO2, TVOCs, and PM0.5 levels exceeded health-based indoor air quality guidelines. Survey results suggest that nursery renovations and related potential pollutant sources may be associated with differences in urbanicity, income, and presence of older children with respiratory ailments, which could potentially confound health studies. While there are no standards for indoor residential air quality, our findings suggest that additional research is needed to assess indoor pollution exposure for infants, which may be a vulnerable population. PMID:22408586

  4. Bois Forte Indoor Air Quality Program

    EPA Pesticide Factsheets

    The Bois Forte Indoor Air Quality Program acted swiftly and aggressively to tackle mold and moisture problems in its community members’ homes after several residents became ill as a result of environmental exposures.

  5. Indoor Air Quality Manual.

    ERIC Educational Resources Information Center

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  6. [Indoor air quality in schools].

    PubMed

    Cartieaux, E; Rzepka, M-A; Cuny, D

    2011-07-01

    Indoor air quality in schools has received particular attention over the past several years. Children are considered as one of the most sensitive groups to atmospheric pollution because their bodies are actively growing and they breathe higher volumes of air relative to their body weights than adults do. They also spend more time in school or group structures (preschools, day nurseries) than in any indoor environments other than the home. The analysis of children's exposure to air pollution at school requires the identification of the main pollutant sources present in these educational institutions. Both a strong contribution of outdoor pollution and a very specific pollution bound to school activities such as the use of paints, markers, glues, and manufactured ink eraser pens, exist. The ventilation in school buildings also plays an important role in air quality. A higher air exchange may improve thermal comfort and air quality. The cause of indoor air pollution is a combinatory effect of physical, chemical, and biological factors, and the adequacy of ventilation in the environment. Several pollutants have been reported to exist in classrooms such as bacteria, molds, volatile organic compounds, persistent organic pollutants and microparticles. There is a correlation between the concentrations of the pollutants and onset of health problems in schoolchildren. We observe predominantly respiratory symptoms as well as a prevalence of respiratory diseases such as asthma and allergies. This study shows that poor indoor air quality affects children's health.

  7. Transforming air quality management

    SciTech Connect

    Janet McCabe

    2005-04-01

    Earlier this year, the Clean Air Act Advisory Committee submitted to EPA 38 recommendations intended to improve air quality management in the United States. This article summarizes the evaluation process leading up to the Committee's recommendations. 3 refs., 2 figs.

  8. Air Quality Modeling

    EPA Pesticide Factsheets

    In this technical support document (TSD) EPA describes the air quality modeling performed to support the Environmental Protection Agency’s Transport Rule proposal (now known as the Cross-State Air Pollution Rule).

  9. Air Quality Analysis

    EPA Pesticide Factsheets

    This site provides information for air quality data analysts inside and outside EPA. Much of the information is in the form of documented analyses that support the review of the national air qualiyt standards.

  10. Indoor air quality and human health

    SciTech Connect

    Turiel, I.

    1985-01-01

    The air inside buildings can contain various threats to human health: cigarette smoke, fumes from fires and cookers, microbes, gases, allergens and fumes produced by household products or building materials. Higher standards of insulation and draught-proofing and more use of air conditioning can increase the problems. This book provides a summary of indoor air quality problems in homes, offices and public buildings. Contents: Preface; Introduction; Formaledhyde and other household contaminants; Radon; Particulates; Combustion products; Involuntary smoking; Energy-efficient buildings and indoor air quality; Control of indoor air pollutants; Indoor air quality problems in office buildings; Legal and regulatory issues; Appendices; Sources and suggested reading; Glossary; Index.

  11. Pigeons home faster through polluted air

    NASA Astrophysics Data System (ADS)

    Li, Zhongqiu; Courchamp, Franck; Blumstein, Daniel T.

    2016-01-01

    Air pollution, especially haze pollution, is creating health issues for both humans and other animals. However, remarkably little is known about how animals behaviourally respond to air pollution. We used multiple linear regression to analyse 415 pigeon races in the North China Plain, an area with considerable air pollution, and found that while the proportion of pigeons successfully homed was not influenced by air pollution, pigeons homed faster when the air was especially polluted. Our results may be explained by an enhanced homing motivation and possibly an enriched olfactory environment that facilitates homing. Our study provides a unique example of animals’ response to haze pollution; future studies are needed to identify proposed mechanisms underlying this effect.

  12. Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System

    PubMed Central

    de Gennaro, Gianluigi; Dambruoso, Paolo Rosario; Di Gilio, Alessia; Di Palma, Valerio; Marzocca, Annalisa; Tutino, Maria

    2015-01-01

    Around 50% of the world’s population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m3, 350.7 μg/m3 and 16.8 μg/m3 respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m3, while the maximum and the minimum values were 24.0 ng/m3 and 1.5 ng/m3, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants’ concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system. PMID:26712773

  13. Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

    PubMed

    de Gennaro, Gianluigi; Dambruoso, Paolo Rosario; Di Gilio, Alessia; Di Palma, Valerio; Marzocca, Annalisa; Tutino, Maria

    2015-12-24

    Around 50% of the world's population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m³, 350.7 μg/m³ and 16.8 μg/m³ respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m³, while the maximum and the minimum values were 24.0 ng/m³ and 1.5 ng/m³, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants' concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.

  14. Perspectives on Home Care Quality

    PubMed Central

    Kane, Rosalie A.; Kane, Robert L.; Illston, Laurel H.; Eustis, Nancy N.

    1994-01-01

    Home care quality assurance (QA) must consider features inherent in home care, including: multiple goals, limited provider control, and unique family roles. Successive panels of stakeholders were asked to rate the importance of selected home care outcomes. Most highly rated outcomes were freedom from exploitation, satisfaction with care, physical safety, affordability, and physical functioning. Panelists preferred outcome indicators to process and structure, and all groups emphasized “enabling” criteria. Themes highlighted included: interpersonal components of care; normalizing life for clientele; balancing quality of life with safety; developing flexible, negotiated care plans; mechanisms for accountability and case management. These themes were formulated differently according to the stakeholders' role. Providers preferred intermediate outcomes, akin to process. PMID:10140158

  15. Quality of Life in Group Homes and Older Persons' Homes

    ERIC Educational Resources Information Center

    Higgins, Laura; Mansell, Jim

    2009-01-01

    Older people with intellectual disabilities sometimes live in older people's homes rather than homes for people with intellectual disabilities. Little is known about their quality of life in these homes. A non-equivalent comparison group design was used to compare the quality of life of 59 people in three groups; older people without an…

  16. Culture systems: air quality.

    PubMed

    Thomas, Theodore

    2012-01-01

    Poor laboratory air quality is a known hazard to the culture of human gametes and embryos. Embryologists and chemists have employed analytical methods for identifying and measuring bulk and select air pollutants to assess the risk they pose to the embryo culture system. However, contaminant concentrations that result in gamete or embryotoxicity are poorly defined. Combating the ill effects of poor air quality requires an understanding of how toxicants can infiltrate the laboratory, the incubator, and ultimately the culture media. A further understanding of site-specific air quality can then lead to the consideration of laboratory design and management strategies that can minimize the deleterious effects that air contamination may have on early embryonic development in vitro.

  17. Air Quality Implementation Plans

    EPA Pesticide Factsheets

    States must develop plans to attain and maintain air quality standards. These plans, known as SIPs, are submitted to EPA for approval. This web site contains information about this process and the current status of the submittals.

  18. Improving Indoor Air Quality

    EPA Pesticide Factsheets

    Usually the most effective way to improve indoor air quality is to eliminate individual sources of pollution or to reduce their emissions. Some sources, like those that contain asbestos, can be sealed or enclosed.

  19. Process air quality data

    NASA Technical Reports Server (NTRS)

    Butler, C. M.; Hogge, J. E.

    1978-01-01

    Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

  20. State Air Quality Standards.

    ERIC Educational Resources Information Center

    Pollution Engineering, 1978

    1978-01-01

    This article presents in tabular form the air quality standards for sulfur dioxide, carbon monoxide, nitrogen dioxide, photochemicals, non-methane hydrocarbons and particulates for each of the 50 states and the District of Columbia. (CS)

  1. State Air Quality Standards.

    ERIC Educational Resources Information Center

    Pollution Engineering, 1978

    1978-01-01

    This article presents in tabular form the air quality standards for sulfur dioxide, carbon monoxide, nitrogen dioxide, photochemicals, non-methane hydrocarbons and particulates for each of the 50 states and the District of Columbia. (CS)

  2. Future Development of Nursing Home Quality Indicators

    ERIC Educational Resources Information Center

    Arling, Greg; Kane, Robert L.; Lewis, Teresa; Mueller, Christine

    2005-01-01

    Nursing home quality indicators have been developed over the past 10 years to quantify nursing home quality and to draw systematic comparisons between facilities. Although these indicators have been applied widely for nursing home regulation, quality improvement, and public reporting, researchers and stakeholders have raised concerns about their…

  3. Future Development of Nursing Home Quality Indicators

    ERIC Educational Resources Information Center

    Arling, Greg; Kane, Robert L.; Lewis, Teresa; Mueller, Christine

    2005-01-01

    Nursing home quality indicators have been developed over the past 10 years to quantify nursing home quality and to draw systematic comparisons between facilities. Although these indicators have been applied widely for nursing home regulation, quality improvement, and public reporting, researchers and stakeholders have raised concerns about their…

  4. Air quality [Chapter 8

    Treesearch

    R. C. Musselman

    1994-01-01

    Air quality is monitored continuously at GLEES. Air pollutants are considered an important component of the atmosphere that can have an effect on terrestrial and aquatic ecosystems. Atmospheric deposition of gases, wet deposition of chemicals in precipitation including snow and rain, and dry deposition of chemicals are all monitored at GLEES. Although GLEES is a...

  5. Developing air quality forecasts

    NASA Astrophysics Data System (ADS)

    Lee, Pius; Saylor, Rick; Meagher, James

    2012-05-01

    Third International Workshop on Air Quality Forecasting Research; Potomac, Maryland, 29 November to 1 December 2011 Elevated concentrations of both near-surface ozone (O3) and fine particulate matter smaller than 2.5 micrometers in diameter have been implicated in increased mortality and other human health impacts. In light of these known influences on human health, many governments around the world have instituted air quality forecasting systems to provide their citizens with advance warning of impending poor air quality so that they can take actions to limit exposure. In an effort to improve the performance of air quality forecasting systems and provide a forum for the exchange of the latest research in air quality modeling, the International Workshop on Air Quality Forecasting Research (IWAQFR) was established in 2009 and is cosponsored by the U.S. National Oceanic and Atmospheric Administration (NOAA), Environment Canada (EC), and the World Meteorological Organization (WMO). The steering committee for IWAQFR's establishment was composed of Véronique Bouchet, Mike Howe, and Craig Stoud (EC); Greg Carmichael (University of Iowa); Paula Davidson and Jim Meagher (NOAA); and Liisa Jalkanen (WMO). The most recent workshop took place in Maryland.

  6. Asthma and domestic air quality.

    PubMed

    Jones, A P

    1998-09-01

    In recent years, there has been a global increase in the prevalence of asthma. This has coincided with many modifications to the home environment, resulting in changes to the quality of indoor air. This article considers the links between indoor air pollution and asthma. Exposure to a range of pollutants is examined. Airborne allergens such as those from house dust mites and cockroaches, domestic pets and moulds and fungal spores may be important. Pollution from particulate materials associated with bio-fuel combustion and smoking is discussed, as is the role of chemical vapours and gases including nitrogen dioxide, formaldehyde and volatile organic compounds. The efficacy of various environmental controls to limit the impact of these pollutants is explored. It is concluded that indoor air pollution may be an important risk for asthma and the health impacts of building design and management require greater recognition and further research.

  7. Multipollutant air quality management.

    PubMed

    Hidy, George M; Pennell, William T

    2010-06-01

    On the basis of a recent NARSTO assessment, this review discusses the factors involved in the implementation of a risk- and results-based multipollutant air quality management strategy applicable to North America. Such a strategy could evolve from current single-pollutant regulatory practices using a series of steps that would seek to minimize risk of exposure for humans and ecosystems while providing for a quantitative evaluation of the effectiveness of the management process. The tools needed to support multipollutant air quality management are summarized. They include application of a formal risk analysis, accounting for atmospheric processes, ambient measurements, emissions characterization, air quality modeling of emissions to ambient concentrations, and characterization of human and ecological responses to ambient pollutant exposure. The new management strategy would expand the current practice of accountability that relates emission reductions and attainment of air quality derived from air quality criteria and standards. Conceptually, achievement of accountability would establish goals optimizing risk reduction associated with pollution management. This expanded approach takes into account the sequence of processes from emissions reduction to resulting changes in ambient concentration. Using ambient concentration as a proxy for exposure, the resulting improvement in human and ecosystem health is estimated. The degree to which this chain of processes and effects can be achieved in current practice is examined in a multipollutant context exemplified by oxidants, as indicated by ozone, particulate matter, and some hazardous air pollutants. Achievement of a multipollutant management strategy will mostly depend on improving knowledge about human and ecosystem response to pollutant exposure.

  8. Traffic air quality index.

    PubMed

    Bagieński, Zbigniew

    2015-02-01

    Vehicle emissions are responsible for a considerable share of urban air pollution concentrations. The traffic air quality index (TAQI) is proposed as a useful tool for evaluating air quality near roadways. The TAQI associates air quality with the equivalent emission from traffic sources and with street structure (roadway structure) as anthropogenic factors. The paper presents a method of determining the TAQI and defines the degrees of harmfulness of emitted pollution. It proposes a classification specifying a potential threat to human health based on the TAQI value and shows an example of calculating the TAQI value for real urban streets. It also considers the role that car traffic plays in creating a local UHI. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    EPA Science Inventory

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  10. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    EPA Science Inventory

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  11. Introduction to Indoor Air Quality

    MedlinePlus

    ... as conditions caused by outdoor impacts (such as climate change). Many reports and studies indicate that the following ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup IAQ at Home Indoor airPLUS Mold ...

  12. Air Quality Management Process Cycle

    EPA Pesticide Factsheets

    Air quality management are activities a regulatory authority undertakes to protect human health and the environment from the harmful effects of air pollution. The process of managing air quality can be illustrated as a cycle of inter-related elements.

  13. Air quality risk management.

    PubMed

    Williams, Martin L

    2008-01-01

    Rather than attempt to provide a comprehensive account of air quality risk assessment, as might be found in a textbook or manual, this article discusses some issues that are of current importance in the United Kingdom and the rest of Europe, with special emphasis on risk assessment in the context of policy formulation, and emerging scientific knowledge. There are two pollutants of particular concern and that both pose challenges for risk assessment and policy, and they are particulate matter (PM) and ozone. The article describes some issues for health risk assessment and finally some forward-looking suggestions for future approaches to air quality management.

  14. Home Air Purifiers Eradicate Harmful Pathogens

    NASA Technical Reports Server (NTRS)

    2014-01-01

    Marshall Space Flight Center funded the University of Madison-Wisconsin to develop ethylene scrubbers to keep produce fresh in space. Akida Holdings of Jacksonville, Florida, licensed the technology and developed Airocide, an air purifier that can kill airborne pathogens. Previously designed for industrial spaces, there is now a specially designed unit for home use.

  15. Air Pollution Monitoring | Air Quality Planning & Standards ...

    EPA Pesticide Factsheets

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  16. Tribal Air Quality Monitoring.

    ERIC Educational Resources Information Center

    Wall, Dennis

    2001-01-01

    The Institute for Tribal Environmental Professionals (ITEP) (Flagstaff, Arizona) provides training and support for tribal professionals in the technical job skills needed for air quality monitoring and other environmental management tasks. ITEP also arranges internships, job placements, and hands-on training opportunities and supports an…

  17. Tribal Air Quality Monitoring.

    ERIC Educational Resources Information Center

    Wall, Dennis

    2001-01-01

    The Institute for Tribal Environmental Professionals (ITEP) (Flagstaff, Arizona) provides training and support for tribal professionals in the technical job skills needed for air quality monitoring and other environmental management tasks. ITEP also arranges internships, job placements, and hands-on training opportunities and supports an…

  18. Assessing Quality in Home Visiting Programs

    ERIC Educational Resources Information Center

    Korfmacher, Jon; Laszewski, Audrey; Sparr, Mariel; Hammel, Jennifer

    2013-01-01

    Defining quality and designing a quality assessment measure for home visitation programs is a complex and multifaceted undertaking. This article summarizes the process used to create the Home Visitation Program Quality Rating Tool (HVPQRT) and identifies next steps for its development. The HVPQRT measures both structural and dynamic features of…

  19. Assessing Quality in Home Visiting Programs

    ERIC Educational Resources Information Center

    Korfmacher, Jon; Laszewski, Audrey; Sparr, Mariel; Hammel, Jennifer

    2013-01-01

    Defining quality and designing a quality assessment measure for home visitation programs is a complex and multifaceted undertaking. This article summarizes the process used to create the Home Visitation Program Quality Rating Tool (HVPQRT) and identifies next steps for its development. The HVPQRT measures both structural and dynamic features of…

  20. Ambient Air Quality Data Inventory

    EPA Pesticide Factsheets

    The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as state, local, and tribal air pollution control agencies. Its component data sets have been collected over the years from approximately 10,000 monitoring sites, of which approximately 5,000 are currently active. OAR's Office of Air Quality Planning and Standards (OAQPS) and other internal and external users, rely on this data to assess air quality, assist in Attainment/Non-Attainment designations, evaluate State Implementation Plans for Non-Attainment Areas, perform modeling for permit review analysis, and other air quality management functions. Air quality information is also used to prepare reports for Congress as mandated by the Clean Air Act. This data covers air quality data collected after 1980, when the Clean Air Act requirements for monitoring were significantly modified. Air quality data from the Agency's early years (1970s) remains available (see OAR PRIMARY DATA ASSET: Ambient Air Quality Data -- Historical), but because of technical and definitional differences the two data assets are not directly comparable. The Clean Air Act of 1970 provided initial authority for monitoring air quality for Conventional Air Pollutants (CAPs) for which EPA has promulgated National Ambient Air Quality Standards (NAAQS). Requirements for monitoring visibility-related parameters were added in 1977. Requiremen

  1. Flood Cleanup to Protect Indoor Air Quality

    EPA Pesticide Factsheets

    During a flood cleanup, the indoor air quality in your home or office may appear to be the least of your problems. However, failure to remove contaminated materials and to reduce moisture and humidity can present serious long-term health risks.

  2. Influence of surficial soil and bedrock on indoor radon in New York State homes. Task 2, Subtask 2 of an investigation of infiltration and indoor air quality in New York State homes

    SciTech Connect

    Kunz, C.

    1989-10-01

    Radon can enter a building from soil and bedrock through cracks or openings in the basement. Extrapolation from data obtained from studies of miners exposed to high concentrations of radon and other carcinogens over long periods indicates that radon gas in the home poses an increased risk of lung cancer. The project was initiated to determine the characteristics of soil and bedrock that contribute to the availability of radon for infiltration into the home, and the feasibility of using soil characteristics in mapping areas at higher risk for above-average indoor radon in New York State. After conducting soil surveys across the State, the researchers choose four areas for further study. Fifteen homes in each area were tested for indoor air concentrations of radon, air infiltration into the home, radon concentrations in the soil, and the permeability of the soil for gas flow. The researchers concluded that these parameters could be combined to obtain a Radon Index Number to predict mean indoor radon levels for a given area with similar soil geology. However, this measure has a limited ability to predict indoor radon levels for a particular home due to variations in construction as well as differences in soil and bedrock.

  3. Agriculture: Agriculture and Air Quality

    EPA Pesticide Factsheets

    Information on air emissions from agricultural practices, types of agricultural burning, air programs that may apply to agriculture, reporting requirements, and links to state and other federal air-quality information.

  4. Ozone - Current Air Quality Index

    MedlinePlus

    ... 0 - 50) Air quality is considered satisfactory, and air pollution poses little or no risk. AQI: Moderate (51 - ... number of people who are unusually sensitive to air pollution. AQI: Unhealthy for Sensitive Groups (101 - 150) Although ...

  5. 24 CFR 280.20 - Home quality.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Home quality. 280.20 Section 280.20 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF... GRANT PROGRAMS NEHEMIAH HOUSING OPPORTUNITY GRANTS PROGRAM § 280.20 Home quality. (a) Generally....

  6. 24 CFR 280.20 - Home quality.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Home quality. 280.20 Section 280.20 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF... GRANT PROGRAMS NEHEMIAH HOUSING OPPORTUNITY GRANTS PROGRAM § 280.20 Home quality. (a) Generally....

  7. 24 CFR 280.20 - Home quality.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 2 2011-04-01 2011-04-01 false Home quality. 280.20 Section 280.20 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF... GRANT PROGRAMS NEHEMIAH HOUSING OPPORTUNITY GRANTS PROGRAM § 280.20 Home quality. (a) Generally....

  8. 24 CFR 280.20 - Home quality.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Home quality. 280.20 Section 280.20 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF... GRANT PROGRAMS NEHEMIAH HOUSING OPPORTUNITY GRANTS PROGRAM § 280.20 Home quality. (a) Generally....

  9. 24 CFR 280.20 - Home quality.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Home quality. 280.20 Section 280.20 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF... GRANT PROGRAMS NEHEMIAH HOUSING OPPORTUNITY GRANTS PROGRAM § 280.20 Home quality. (a) Generally....

  10. Indoor Air Quality in Apartments

    EPA Pesticide Factsheets

    Apartments can have the same indoor air problems as single-family homes because many of the pollution sources, such as the interior building materials, furnishings, and household products, are similar.

  11. Air Quality and Indoor Environmental Exposures: Clinical ...

    EPA Pesticide Factsheets

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo

  12. Air Quality and Indoor Environmental Exposures: Clinical ...

    EPA Pesticide Factsheets

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo

  13. Care for Your Air: A Guide to Indoor Air Quality

    EPA Pesticide Factsheets

    Understand indoor air in homes, schools, and offices. Most of us spend much of our time indoors. The air that we breathe in our homes, in schools, and in offices can put us at risk for health problems.

  14. Air quality management in Mexico.

    PubMed

    Fernández-Bremauntz, Adrián

    2008-01-01

    Several significant program and policy measures have been implemented in Mexico over the past 15 yr to improve air quality. This article provides an overview of air quality management strategies in Mexico, including (1) policy initiatives such as vehicle use restrictions, air quality standards, vehicle emissions, and fuel quality standards, and (2) supporting programs including establishment of a national emission inventory, an air pollution episodes program, and the implementation of exposure and health effects studies. Trends in air pollution episodes and ambient air pollutant concentrations are described.

  15. Indoor air quality and health

    NASA Astrophysics Data System (ADS)

    Jones, A. P.

    During the last two decades there has been increasing concern within the scientific community over the effects of indoor air quality on health. Changes in building design devised to improve energy efficiency have meant that modern homes and offices are frequently more airtight than older structures. Furthermore, advances in construction technology have caused a much greater use of synthetic building materials. Whilst these improvements have led to more comfortable buildings with lower running costs, they also provide indoor environments in which contaminants are readily produced and may build up to much higher concentrations than are found outside. This article reviews our current understanding of the relationship between indoor air pollution and health. Indoor pollutants can emanate from a range of sources. The health impacts from indoor exposure to combustion products from heating, cooking, and the smoking of tobacco are examined. Also discussed are the symptoms associated with pollutants emitted from building materials. Of particular importance might be substances known as volatile organic compounds (VOCs), which arise from sources including paints, varnishes, solvents, and preservatives. Furthermore, if the structure of a building begins to deteriorate, exposure to asbestos may be an important risk factor for the chronic respiratory disease mesothelioma. The health effects of inhaled biological particles can be significant, as a large variety of biological materials are present in indoor environments. Their role in inducing illness through immune mechanisms, infectious processes, and direct toxicity is considered. Outdoor sources can be the main contributors to indoor concentrations of some contaminants. Of particular significance is Radon, the radioactive gas that arises from outside, yet only presents a serious health risk when found inside buildings. Radon and its decay products are now recognised as important indoor pollutants, and their effects are

  16. Green House Adoption and Nursing Home Quality.

    PubMed

    Afendulis, Christopher C; Caudry, Daryl J; O'Malley, A James; Kemper, Peter; Grabowski, David C

    2016-02-01

    To evaluate the impact of the Green House (GH) model on nursing home resident-level quality of care measures. Resident-level minimum data set (MDS) assessments merged with Medicare inpatient claims for the period 2005 through 2010. Using a difference-in-differences framework, we compared changes in care quality and outcomes in 15 nursing homes that adopted the GH model relative to changes over the same time period in 223 matched nursing homes that had not adopted the GH model. For individuals residing in GH homes, adoption of the model lowered readmissions and several MDS measures of poor quality, including bedfast residents, catheter use, and pressure ulcers, but these results were not present across the entire GH organization, suggesting possible offsetting effects for residents of non-GH "legacy" units within the GH organization. GH adoption led to improvement in rehospitalizations and certain nursing home quality measures for individuals residing in a GH home. The absence of evidence of a decline in other clinical quality measures in GH nursing homes should reassure anyone concerned that GH might have sacrificed clinical quality for improved quality of life. © Health Research and Educational Trust.

  17. Indoor Air Quality in Schools.

    ERIC Educational Resources Information Center

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  18. Air Quality System (AQS) Metadata

    EPA Pesticide Factsheets

    The U.S. Environmental Protection Agency compiles air quality monitoring data in the Air Quality System (AQS). Ambient air concentrations are measured at a national network of more than 4,000 monitoring stations and are reported by state, local, and tribal

  19. Air Tightness of US Homes: Model Development

    SciTech Connect

    Sherman, Max H.

    2006-05-01

    Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. The Lawrence Berkeley National Laboratory has been gathering residential air leakage data from many sources and now has a database of more than 100,000 raw measurements. This paper uses that database to develop a model for estimating air leakage as a function of climate, building age, floor area, building height, floor type, energy-efficiency and low-income designations. The model developed can be used to estimate the leakage distribution of populations of houses.

  20. Cleaner Air for Home and Office

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Increased insulation has led to higher concentrations in homes and offices of toxic chemicals caused by emissions from synthetic building components. Recent NASA research regarding future interplanetary manned spacecraft has shown that certain plants can absorb gasses, reducing indoor air pollution. After working with water purifying water hyacinths, Dr. B. C. Wolverton at NSTL developed a carbon/plant filter system to remove chemicals, smoke, etc. Two companies have commercialized the system. Bio-safe provides plants, a bed of activated carbon and an air pump installed near the plant's roots. Pollutants are trapped by the charcoal and either digested by the roots or broken down by microorganisms. Purified air is then directed back into the room. Applied Indoor Resource Company markets Bio-Pure, which includes plants on a layer of patented soil medium with activated carbon. Legumes and mosses filter the air; a blower moves air through the filtering system for cleansing by microorganisms. Research at NSTL continues, and the system may eventually be enlarged.

  1. Ensuring Quality Nursing Home Care

    MedlinePlus

    ... activities offered.Activities help nursing home residents remain social and stimulated. These may include: • arts and craft classes • chair exercise programs • religious services • discussion groups • entertainment ( ...

  2. Managing Air Quality - Program Implementation

    EPA Pesticide Factsheets

    Describes elements for the set of activities to ensure that control strategies are put into effect and that air quality goals and standards are fulfilled, permitting programs, and additional resources related to implementation under the Clean Air Act.

  3. Air Quality Monitor

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Stak-Tracker CEM (Continuous Emission Monitor) Gas Analyzer is an air quality monitor capable of separating the various gases in a bulk exhaust stream and determining the amounts of individual gases present within the stream. The monitor is produced by GE Reuter- Stokes, a subsidiary of GE Corporate Research & Development Center. The Stak-Tracker uses a Langley Research Center software package which measures the concentration of a target gas by determining the degree to which molecules of that gas absorb an infrared beam. The system is environmental-friendly, fast and has relatively low installation and maintenance costs. It is applicable to gas turbines and various industries including glass, paper and cement.

  4. Indoor Air Quality in Schools

    EPA Pesticide Factsheets

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  5. Clearing the Air about Home Schooling.

    ERIC Educational Resources Information Center

    Pawlas, George E.

    2001-01-01

    Home school is evolving and gaining popularity in the United States. This paper describes different methods of home schooling, presents various home schooling resources that are available, and discusses the relationships between home schooling families and public schools, noting that a relationship between schools and home schools could be…

  6. Indoor Air Quality

    MedlinePlus

    ... are especially vulnerable to the harmful effects of air pollution. Cleaning up pollution in their schools will help ... nothing else matters ® . Help us fight to reduce pollution in the air we breathe. Donate

  7. [Air quality and climate change].

    PubMed

    Loft, Steffen

    2009-10-26

    Air quality, health and climate change are closely connected. Ozone depends on temperature and the greenhouse gas methane from cattle and biomass. Pollen presence depends on temperature and CO2. The effect of climate change on particulate air pollution is complex, but the likely net effect is greater health risks. Reduction of greenhouse-gas emissions by reduced livestock production and use of combustion for energy production, transport and heating will also improve air quality. Energy savings in buildings and use of CO2 neutral fuels should not deteriorate indoor and outdoor air quality.

  8. New Federal Air Quality Standards.

    ERIC Educational Resources Information Center

    Stopinski, O. W.

    The report discusses the current procedures for establishing air quality standards, the bases for standards, and, finally, proposed and final National Primary and Secondary Ambient Air Quality Standards for sulfur dioxide, particulate matter, carbon monoxide, nonmethane hydrocarbons, photochemical oxidants, and nitrogen dioxide. (Author/RH)

  9. New Federal Air Quality Standards.

    ERIC Educational Resources Information Center

    Stopinski, O. W.

    The report discusses the current procedures for establishing air quality standards, the bases for standards, and, finally, proposed and final National Primary and Secondary Ambient Air Quality Standards for sulfur dioxide, particulate matter, carbon monoxide, nonmethane hydrocarbons, photochemical oxidants, and nitrogen dioxide. (Author/RH)

  10. Building Air Quality. Action Plan.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Indoor Air Div.

    Building managers and owners often confront competing demands to reduce operating costs and increase revenues that can siphon funds and resources from other building management concerns such as indoor air quality (IAQ). This resource booklet, designed for use with the "Building Air Quality Guide," provides building owners and managers with an…

  11. Indoor air quality medicolegal issues.

    PubMed

    Ross, C S; Lockey, J E

    1994-08-01

    The regulatory and legal communities have begun only recently to address the medicolegal issues surrounding indoor air quality. No single governmental agency is responsible for indoor air quality issues. The focus of the federal government's indoor air quality programs is on the gathering and dissemination of information rather than on the regulation of indoor air pollution. State and local regulatory controls vary but may include antismoking ordinances, building codes, and contractor certification programs. Numerous lawsuits involving various parties and legal theories have been filed on the basis of illness allegedly related to indoor air quality. Further regulatory and legal review of indoor air problems will likely occur in the near future, particularly as a result of the characterization of environmental tobacco smoke as a class A carcinogen.

  12. Is higher nursing home quality more costly?

    PubMed

    Giorgio, L Di; Filippini, M; Masiero, G

    2016-11-01

    Widespread issues regarding quality in nursing homes call for an improved understanding of the relationship with costs. This relationship may differ in European countries, where care is mainly delivered by nonprofit providers. In accordance with the economic theory of production, we estimate a total cost function for nursing home services using data from 45 nursing homes in Switzerland between 2006 and 2010. Quality is measured by means of clinical indicators regarding process and outcome derived from the minimum data set. We consider both composite and single quality indicators. Contrary to most previous studies, we use panel data and control for omitted variables bias. This allows us to capture features specific to nursing homes that may explain differences in structural quality or cost levels. Additional analysis is provided to address simultaneity bias using an instrumental variable approach. We find evidence that poor levels of quality regarding outcome, as measured by the prevalence of severe pain and weight loss, lead to higher costs. This may have important implications for the design of payment schemes for nursing homes.

  13. 24 CFR 982.621 - Manufactured home: Housing quality standards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Manufactured home: Housing quality... Types Manufactured Home § 982.621 Manufactured home: Housing quality standards. A manufactured home must meet all the HQS performance requirements and acceptability criteria in § 982.401. A manufactured home...

  14. Energy Savings Plus Health Indoor Air Quality Guidelines for Multifamily Building Upgrades

    EPA Pesticide Factsheets

    Remodeling or renovating an existing multifamily building not only has the potential to release pollutants into the home; it is also an opportunity to make changes that will improve the indoor air quality in your home.

  15. How to Use the Indoor Air Quality Guidelines for Multifamily Building Upgrades

    EPA Pesticide Factsheets

    Remodeling or renovating an existing multifamily building not only has the potential to release pollutants into the home; it is also an opportunity to make changes that will improve the indoor air quality in your home.

  16. Nursing home care quality: a cluster analysis.

    PubMed

    Grøndahl, Vigdis Abrahamsen; Fagerli, Liv Berit

    2017-02-13

    Purpose The purpose of this paper is to explore potential differences in how nursing home residents rate care quality and to explore cluster characteristics. Design/methodology/approach A cross-sectional design was used, with one questionnaire including questions from quality from patients' perspective and Big Five personality traits, together with questions related to socio-demographic aspects and health condition. Residents ( n=103) from four Norwegian nursing homes participated (74.1 per cent response rate). Hierarchical cluster analysis identified clusters with respect to care quality perceptions. χ(2) tests and one-way between-groups ANOVA were performed to characterise the clusters ( p<0.05). Findings Two clusters were identified; Cluster 1 residents (28.2 per cent) had the best care quality perceptions and Cluster 2 (67.0 per cent) had the worst perceptions. The clusters were statistically significant and characterised by personal-related conditions: gender, psychological well-being, preferences, admission, satisfaction with staying in the nursing home, emotional stability and agreeableness, and by external objective care conditions: healthcare personnel and registered nurses. Research limitations/implications Residents assessed as having no cognitive impairments were included, thus excluding the largest group. By choosing questionnaire design and structured interviews, the number able to participate may increase. Practical implications Findings may provide healthcare personnel and managers with increased knowledge on which to develop strategies to improve specific care quality perceptions. Originality/value Cluster analysis can be an effective tool for differentiating between nursing homes residents' care quality perceptions.

  17. Canada-wide standards and innovative transboundary air quality initiatives.

    PubMed

    Barton, Jane

    2008-01-01

    Canada's approach to air quality management is one that has brought with it opportunities for the development of unique approaches to risk management. Even with Canada's relatively low levels of pollution, science has demonstrated clearly that air quality and ecosystem improvements are worthwhile. To achieve change and address air quality in Canada, Canadian governments work together since, under the constitution, they share responsibility for the environment. At the same time, because air pollution knows no boundaries, working with the governments of other nations is essential to get results. International cooperation at all levels provides opportunities with potential for real change. Cooperation within transboundary airsheds is proving a fruitful source of innovative opportunities to reduce cross-border barriers to air quality improvements. In relation to the NERAM Colloquium objective to establish principles for air quality management based on the identification of international best practice in air quality policy development and implementation, Canada has developed, both at home and with the United States, interesting air management strategies and initiatives from which certain lessons may be taken that could be useful in other countries with similar situations. In particular, the Canada-wide strategies for smog and acid rain were developed by Canadian governments, strategies that improve and protect air quality at home, while Canada-U.S. transboundary airshed projects provide examples of international initiatives to improve air quality.

  18. Colorado Air Quality Control Regulations and Ambient Air Quality Standards.

    ERIC Educational Resources Information Center

    Colorado State Dept. of Health, Denver. Div. of Air Pollution Control.

    Regulations and standards relative to air quality control in Colorado are defined in this publication. Presented first are definitions of terms, a statement of intent, and general provisions applicable to all emission control regulations adopted by the Colorado Air Pollution Control Commission. Following this, three regulations are enumerated: (1)…

  19. Quality Assurance Strategy for Existing Homes: Final Quality Management Primer for High Performing Homes

    SciTech Connect

    Del Bianco, M.; Taggart, J.; Sikora, J.; Wood, A.

    2012-12-01

    This guide is designed to help Building America (BA) Teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  20. Quality Assurance Strategy for Existing Homes. Final Quality Management Primer for High Performing Homes

    SciTech Connect

    Del Bianco, M.; Taggart, J.; Sikora, J.; Wood, A.

    2012-12-01

    This guide is designed to help Building America (BA) teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  1. Text Version of the Indoor Air Quality House Tour

    EPA Pesticide Factsheets

    Get a quick glimpse of some of the most important ways to protect the air in your home by touring the Indoor Air Quality (IAQ) House. Room-by-room, you'll learn about the key pollutants and how to address them.

  2. Community Multiscale Air Quality Modeling System (CMAQ)

    EPA Pesticide Factsheets

    CMAQ is a computational tool used for air quality management. It models air pollutants including ozone, particulate matter and other air toxics to help determine optimum air quality management scenarios.

  3. Indoor Air Quality

    NASA Astrophysics Data System (ADS)

    Miyazaki, Takeji

    The reduction of intake of outdoor air volume in air conditioned buildings, adopted as the strategy for saving energy, has caused sick building syndrome abroad. Such symptoms of sick building as headache, stimuli of eye and nose and lethargy, appears to result from cigarette smoke, folmaldehyde and volatile organic carbons. On the other hand, in airtight residences not only carbon monoxide and nitrogen oxides from domestic burning appliances but also allergens of mite, fungi, pollen and house dust, have become a subject of discussion. Moreover, asbestos and radon of carcinogen now attract a great deal of attention. Those indoor air pollutants are discussed.

  4. Perception, culture, and science: A framework to identify in-home heating options to improve indoor air quality in the Navajo Nation.

    PubMed

    Champion, W M; Charley, P H; Klein, B; Stewart, K; Solomon, P A; Montoya, L D

    2017-02-15

    A 2010 study identified higher than average incidence of respiratory disease in Shiprock, NM, the largest city in the Navajo Nation. That study suggested that the potential cause was the combustion of solid fuels in in-home heating stoves and that respiratory disease could be greatly reduced by changing indoor heating behaviors and improving heating stove quality. Since the Navajo people are deeply embedded in culture and traditions that strongly influence their daily lives, a new framework was needed to identify feasible heating alternatives that could reduce the negative environmental and health impacts related to solid fuel use while respecting the culture of the Navajo people. The resulting Navajo framework included perception, cultural, and technical assessments to evaluate seven heating alternatives perceived viable by Navajo stakeholders. Cultural experts at the Diné Policy Institute identified potential cultural limitations and motivating factors for each alternative. A limited technical assessment of the health benefits of these options was conducted and integrated into the process. A parallel convergent mixed-methods approach was employed to integrate qualitative and quantitative results. The results and framework developed and presented here may be useful for decision makers in communities heavily reliant on solid fuels for heat, especially Native Nations, where culture plays an important role in the success of any intervention.

  5. Managing Air Quality - Emissions Inventories

    EPA Pesticide Factsheets

    This page describes the role of emission inventories in the air quality management process, a description of how emission inventories are developed, and where U.S. emission inventory information can be found.

  6. Mind Your Indoor Air Quality

    ERIC Educational Resources Information Center

    Mak, Lily

    2012-01-01

    When it comes to excelling in the classroom, it turns out the air students are breathing is just as important as the lessons they are learning. Studies show poor indoor air quality (IAQ) can lessen the comfort of students as well as staff--affecting concentration, attendance and student performance. It can even lead to lower IQs. What's more, poor…

  7. Mind Your Indoor Air Quality

    ERIC Educational Resources Information Center

    Mak, Lily

    2012-01-01

    When it comes to excelling in the classroom, it turns out the air students are breathing is just as important as the lessons they are learning. Studies show poor indoor air quality (IAQ) can lessen the comfort of students as well as staff--affecting concentration, attendance and student performance. It can even lead to lower IQs. What's more, poor…

  8. What Is Nursing Home Quality and How Is It Measured?

    ERIC Educational Resources Information Center

    Castle, Nicholas G.; Ferguson, Jamie C.

    2010-01-01

    Purpose: In this commentary, we examine nursing home quality and indicators that have been used to measure nursing home quality. Design and Methods: A brief review of the history of nursing home quality is presented that provides some context and insight into currently used quality indicators. Donabedian's structure, process, and outcome (SPO)…

  9. What Is Nursing Home Quality and How Is It Measured?

    ERIC Educational Resources Information Center

    Castle, Nicholas G.; Ferguson, Jamie C.

    2010-01-01

    Purpose: In this commentary, we examine nursing home quality and indicators that have been used to measure nursing home quality. Design and Methods: A brief review of the history of nursing home quality is presented that provides some context and insight into currently used quality indicators. Donabedian's structure, process, and outcome (SPO)…

  10. Air quality and climate connections.

    PubMed

    Fiore, Arlene M; Naik, Vaishali; Leibensperger, Eric M

    2015-06-01

    Multiple linkages connect air quality and climate change. Many air pollutant sources also emit carbon dioxide (CO2), the dominant anthropogenic greenhouse gas (GHG). The two main contributors to non-attainment of U.S. ambient air quality standards, ozone (O3) and particulate matter (PM), interact with radiation, forcing climate change. PM warms by absorbing sunlight (e.g., black carbon) or cools by scattering sunlight (e.g., sulfates) and interacts with clouds; these radiative and microphysical interactions can induce changes in precipitation and regional circulation patterns. Climate change is expected to degrade air quality in many polluted regions by changing air pollution meteorology (ventilation and dilution), precipitation and other removal processes, and by triggering some amplifying responses in atmospheric chemistry and in anthropogenic and natural sources. Together, these processes shape distributions and extreme episodes of O3 and PM. Global modeling indicates that as air pollution programs reduce SO2 to meet health and other air quality goals, near-term warming accelerates due to "unmasking" of warming induced by rising CO2. Air pollutant controls on CH4, a potent GHG and precursor to global O3 levels, and on sources with high black carbon (BC) to organic carbon (OC) ratios could offset near-term warming induced by SO2 emission reductions, while reducing global background O3 and regionally high levels of PM. Lowering peak warming requires decreasing atmospheric CO2, which for some source categories would also reduce co-emitted air pollutants or their precursors. Model projections for alternative climate and air quality scenarios indicate a wide range for U.S. surface O3 and fine PM, although regional projections may be confounded by interannual to decadal natural climate variability. Continued implementation of U.S. NOx emission controls guards against rising pollution levels triggered either by climate change or by global emission growth. Improved

  11. Instrumentation for air quality measurements.

    NASA Technical Reports Server (NTRS)

    Loewenstein, M.

    1973-01-01

    Comparison of the new generation of air quality monitoring instruments with some more traditional methods. The first generation of air quality measurement instruments, based on the use of oxidant coulometric cells, nitrogen oxide colorimetry, carbon monoxide infrared analyzers, and other types of detectors, is compared with new techniques now coming into wide use in the air monitoring field and involving the use of chemiluminescent reactions, optical absorption detectors, a refinement of the carbon monoxide infrared analyzer, electrochemical cells based on solid electrolytes, and laser detectors.

  12. Nursing Home Quality as a Common Good

    PubMed Central

    Grabowski, David C.; Gruber, Jonathan; Angelelli, Joseph J.

    2009-01-01

    A long-standing assumption among economists is that nursing home quality is common across Medicaid and private-pay patients within a shared facility. However, there has been only limited empirical work addressing this issue. Using a unique individual level panel of residents of nursing homes from seven states, we exploit both within-facility and within-person variation in payer source and quality to examine this issue. We also test the robustness of these results across states with different Medicaid and private-pay rate differentials. Across various identification strategies, our results are consistent with the assumption of common quality across Medicaid and private-paying patients within facilities. PMID:20463859

  13. Reducing indoor air pollutants with air filtration units in wood stove homes.

    PubMed

    McNamara, Marcy L; Thornburg, Jonathon; Semmens, Erin O; Ward, Tony J; Noonan, Curtis W

    2017-08-15

    Biomass burning has been shown to be a major source of poor indoor air quality (IAQ) in developing and higher income countries across the world. Specifically, wood burning for cooking and heating contributes to high indoor concentrations of fine (particles with aerodynamic diameters<2.5μm; PM2.5) and coarse (particles with aerodynamic diameters <10μm and >2.5μm; PMc) particulate matter. Endotoxin, predominantly found within the coarse fraction of airborne particulate matter, is associated with proinflammatory effects and adverse outcomes among susceptible populations. The aim of this study was to assess the efficacy of air filter interventions in reducing indoor PM2.5, PMc, and PMc-associated endotoxin concentrations in homes using a wood stove for primary heating. Homes (n=48) were randomized to receive in-room air filtration units with either a high efficiency filter (i.e. active) or a lower efficiency fiberglass filter (i.e., placebo). The active filter intervention showed a 66% reduction in indoor PM2.5 concentrations (95% CI: 42.2% to 79.7% reduction) relative to the placebo intervention. Both the active and the placebo filters were effective in substantially reducing indoor concentrations of PMc (63.3% and 40.6% average reduction for active and placebo filters, respectively) and PMc-associated endotoxin concentrations (91.8% and 80.4% average reductions, respectively). These findings support the use of high efficiency air filtration units for reducing indoor PM2.5 in homes using a wood stove for primary heating. We also discovered that using lower efficiency, lower cost filter alternatives can be effective for reducing PMc and airborne endotoxin in homes burning biomass fuel. Copyright © 2017. Published by Elsevier B.V.

  14. Aeromicrobiology/air quality

    USGS Publications Warehouse

    Andersen, Gary L.; Frisch, A.S.; Kellogg, Christina A.; Levetin, E.; Lighthart, Bruce; Paterno, D.

    2009-01-01

    The most prevalent microorganisms, viruses, bacteria, and fungi, are introduced into the atmosphere from many anthropogenic sources such as agricultural, industrial and urban activities, termed microbial air pollution (MAP), and natural sources. These include soil, vegetation, and ocean surfaces that have been disturbed by atmospheric turbulence. The airborne concentrations range from nil to great numbers and change as functions of time of day, season, location, and upwind sources. While airborne, they may settle out immediately or be transported great distances. Further, most viable airborne cells can be rendered nonviable due to temperature effects, dehydration or rehydration, UV radiation, and/or air pollution effects. Mathematical microbial survival models that simulate these effects have been developed.

  15. Urban air quality

    NASA Astrophysics Data System (ADS)

    Fenger, Jes

    Since 1950 the world population has more than doubled, and the global number of cars has increased by a factor of 10. In the same period the fraction of people living in urban areas has increased by a factor of 4. In year 2000 this will amount to nearly half of the world population. About 20 urban regions will each have populations above 10 million people. Seen over longer periods, pollution in major cities tends to increase during the built up phase, they pass through a maximum and are then again reduced, as abatement strategies are developed. In the industrialised western world urban air pollution is in some respects in the last stage with effectively reduced levels of sulphur dioxide and soot. In recent decades however, the increasing traffic has switched the attention to nitrogen oxides, organic compounds and small particles. In some cities photochemical air pollution is an important urban problem, but in the northern part of Europe it is a large-scale phenomenon, with ozone levels in urban streets being normally lower than in rural areas. Cities in Eastern Europe have been (and in many cases still are) heavily polluted. After the recent political upheaval, followed by a temporary recession and a subsequent introduction of new technologies, the situation appears to improve. However, the rising number of private cars is an emerging problem. In most developing countries the rapid urbanisation has so far resulted in uncontrolled growth and deteriorating environment. Air pollution levels are here still rising on many fronts. Apart from being sources of local air pollution, urban activities are significant contributors to transboundary pollution and to the rising global concentrations of greenhouse gasses. Attempts to solve urban problems by introducing cleaner, more energy-efficient technologies will generally have a beneficial impact on these large-scale problems. Attempts based on city planning with a spreading of the activities, on the other hand, may generate

  16. Global Air Quality and Climate

    NASA Technical Reports Server (NTRS)

    Fiore, Arlene M.; Naik, Vaishali; Steiner, Allison; Unger, Nadine; Bergmann, Dan; Prather, Michael; Righi, Mattia; Rumbold, Steven T.; Shindell, Drew T.; Skeie, Ragnhild B.; hide

    2012-01-01

    Emissions of air pollutants and their precursors determine regional air quality and can alter climate. Climate change can perturb the long-range transport, chemical processing, and local meteorology that influence air pollution. We review the implications of projected changes in methane (CH4), ozone precursors (O3), and aerosols for climate (expressed in terms of the radiative forcing metric or changes in global surface temperature) and hemispheric-to-continental scale air quality. Reducing the O3 precursor CH4 would slow near-term warming by decreasing both CH4 and tropospheric O3. Uncertainty remains as to the net climate forcing from anthropogenic nitrogen oxide (NOx) emissions, which increase tropospheric O3 (warming) but also increase aerosols and decrease CH4 (both cooling). Anthropogenic emissions of carbon monoxide (CO) and non-CH4 volatile organic compounds (NMVOC) warm by increasing both O3 and CH4. Radiative impacts from secondary organic aerosols (SOA) are poorly understood. Black carbon emission controls, by reducing the absorption of sunlight in the atmosphere and on snow and ice, have the potential to slow near-term warming, but uncertainties in coincident emissions of reflective (cooling) aerosols and poorly constrained cloud indirect effects confound robust estimates of net climate impacts. Reducing sulfate and nitrate aerosols would improve air quality and lessen interference with the hydrologic cycle, but lead to warming. A holistic and balanced view is thus needed to assess how air pollution controls influence climate; a first step towards this goal involves estimating net climate impacts from individual emission sectors. Modeling and observational analyses suggest a warming climate degrades air quality (increasing surface O3 and particulate matter) in many populated regions, including during pollution episodes. Prior Intergovernmental Panel on Climate Change (IPCC) scenarios (SRES) allowed unconstrained growth, whereas the Representative

  17. Global air quality and climate.

    PubMed

    Fiore, Arlene M; Naik, Vaishali; Spracklen, Dominick V; Steiner, Allison; Unger, Nadine; Prather, Michael; Bergmann, Dan; Cameron-Smith, Philip J; Cionni, Irene; Collins, William J; Dalsøren, Stig; Eyring, Veronika; Folberth, Gerd A; Ginoux, Paul; Horowitz, Larry W; Josse, Béatrice; Lamarque, Jean-François; MacKenzie, Ian A; Nagashima, Tatsuya; O'Connor, Fiona M; Righi, Mattia; Rumbold, Steven T; Shindell, Drew T; Skeie, Ragnhild B; Sudo, Kengo; Szopa, Sophie; Takemura, Toshihiko; Zeng, Guang

    2012-10-07

    Emissions of air pollutants and their precursors determine regional air quality and can alter climate. Climate change can perturb the long-range transport, chemical processing, and local meteorology that influence air pollution. We review the implications of projected changes in methane (CH(4)), ozone precursors (O(3)), and aerosols for climate (expressed in terms of the radiative forcing metric or changes in global surface temperature) and hemispheric-to-continental scale air quality. Reducing the O(3) precursor CH(4) would slow near-term warming by decreasing both CH(4) and tropospheric O(3). Uncertainty remains as to the net climate forcing from anthropogenic nitrogen oxide (NO(x)) emissions, which increase tropospheric O(3) (warming) but also increase aerosols and decrease CH(4) (both cooling). Anthropogenic emissions of carbon monoxide (CO) and non-CH(4) volatile organic compounds (NMVOC) warm by increasing both O(3) and CH(4). Radiative impacts from secondary organic aerosols (SOA) are poorly understood. Black carbon emission controls, by reducing the absorption of sunlight in the atmosphere and on snow and ice, have the potential to slow near-term warming, but uncertainties in coincident emissions of reflective (cooling) aerosols and poorly constrained cloud indirect effects confound robust estimates of net climate impacts. Reducing sulfate and nitrate aerosols would improve air quality and lessen interference with the hydrologic cycle, but lead to warming. A holistic and balanced view is thus needed to assess how air pollution controls influence climate; a first step towards this goal involves estimating net climate impacts from individual emission sectors. Modeling and observational analyses suggest a warming climate degrades air quality (increasing surface O(3) and particulate matter) in many populated regions, including during pollution episodes. Prior Intergovernmental Panel on Climate Change (IPCC) scenarios (SRES) allowed unconstrained growth, whereas

  18. Indoor Air Quality Science and Technology

    EPA Pesticide Factsheets

    Understand indoor air in homes, schools, and offices. Most of us spend much of our time indoors. The air that we breathe in our homes, in schools, and in offices can put us at risk for health problems. Some pollutants can be chemicals, gases, and living or

  19. Air-quality-model update

    SciTech Connect

    Penner, J.E.; Walton, J.J.

    1982-01-15

    The Livermore Regional Air Quality Model (LIRAQ) has been updated and improved. This report describes the changes that have been made in chemistry, species treatment, and boundary conditions. The results of smog chamber simulations that were used to verify the chemistry as well as simulations of the entire air quality model for two prototype days in the Bay Area are reported. The results for the prototype day simulations are preliminary due to the need for improvement in meteorology fields, but they show the dependence and sensitivity of high hour ozone to changes in selected boundary and initial conditions.

  20. Seasonal changes in ground-water quality and ground-water levels and directions of ground-water movement in southern Elmore County, southwestern Idaho, including Mountain Home Air Force Base, 1990-1991

    USGS Publications Warehouse

    Young, H.W.; Parliman, D.J.; Jones, Michael L.

    1992-01-01

    The study area is located in southern Elmore County, southwestern Idaho, and includes the Mountain Home Air Force Base located approximately 10 mi southwest of the city of Mountain Home. Chemical analyzes have been made periodically since the late 1940's on water samples from supply wells on the Air Force Base. These analyses indicate increases in specific conductance and in concentrations of nitrogen compounds, chloride, and sulfate. The purposes of this report, which was prepared in cooperation with the Department of the Air Force, are to describe the seasonal changes in water quality and water levels and to depict the directions of ground-water movement in the regional aquifer system and perched-water zones. Although data presented in this report are from both the regional ground-water system and perched-water zones, the focus is on the regional system. A previous study by the U.S. Geological Survey (Parliman and Young, 1990) describes the areal changes in water quality and water levels during the fall of 1989. During March, July, and October 1990, 141 wells were inventoried and depth to water was measured. Continuous water-level recorders were installed on 5 of the wells and monthly measurements of depth to water were made in 17 of the wells during March 1990 through February 1991. Water samples from 33 wells and 1 spring were collected during the spring and fall of 1990 for chemical analyses. Samples also were collected monthly from 11 of those wells during April to September 1990 (table 1). Selected well-construction and water-use data and measurements of depth to water for 141 wells are given in table 2 (separated sheets in envelope). Directions of ground-water movement and selected hydrographs showing seasonal fluctuations of water levels in the regional ground-water system and perched-water zones are shown on sheet 2. Changes in water levels in the regional ground-water system during March to October 1990 are shown on sheet 2.

  1. An investigation of infiltration and indoor air quality

    SciTech Connect

    Not Available

    1990-09-01

    A multitask study was performed in the State of New York to provide information for guiding home energy conservation programs while maintaining acceptable indoor air quality. During this study, the statistical distribution of radon concentrations inside 2400 homes was determined. The relationships among radon levels, house characteristics, and sources were also investigated. The direct impact that two specific air infiltration reduction measures -- caulking and weatherstripping of windows and doors, and installation of storm windows and storm doors -- have on house air leakage was investigated in 60 homes. The effect of house age on the impact of weatherization was also evaluated. Indoor and outdoor measurements of NO{sub 2}, CO, SO{sub 2}, and respirable suspended particulates (RSP) were made for 400 homes to determine the effect of combustion sources on indoor air quality and to characterize the statistical distribution of the concentrations. Finally, the combustion source data were combined with the information on air infiltration reduction measures to estimate the potential impact of these measures on indoor air quality. 87 tabs.

  2. Home health care quality conferences: promoting change through dialogue.

    PubMed

    Rudin, Danylle

    2006-01-01

    The following brief is based on the results of two conferences on home care quality hosted by the Center for Home Care Policy and Research of the Visiting Nurse Service of New York. For more information about the conference outcomes and proceedings please see: Feldman, P.H.,Peterson, L.E., Reische, L., Bruno, L., & Clark, A. (2004). Charting the course for home healthcare quality: Action steps for achieving sustainable improvement. Conference proceedings. Home Healthcare Nurse, 22(12): 841-850; and Feldman, P.H., Clark, A., & Bruno, L. (2006). Advancing the agenda for home healthcare quality: Conference proceedings and findings. Home Healthcare Nurse, 24(5): 282-290.

  3. Indoor Air Quality Management Program.

    ERIC Educational Resources Information Center

    Anne Arundel County Public Schools, Annapolis, MD.

    In an effort to provide Indoor Air Quality (IAQ) management guidance, Anne Arundel County Public Schools was selected by the Maryland State Department of Education to develop a program that could be used by other school systems. A major goal was to produce a handbook that was "user friendly." Hence, its contents are a mix of history,…

  4. Indoor Air Quality Management Program.

    ERIC Educational Resources Information Center

    Anne Arundel County Public Schools, Annapolis, MD.

    In an effort to provide Indoor Air Quality (IAQ) management guidance, Anne Arundel County Public Schools was selected by the Maryland State Department of Education to develop a program that could be used by other school systems. A major goal was to produce a handbook that was "user friendly." Hence, its contents are a mix of history,…

  5. Indoor Air Quality and Disease

    EPA Science Inventory

    Concern over the quality of indoor (i.e., residential) as well as outdoor (i.e., environmental) air is increasing. Accordingly, owners of companion animals may approach their veterinarian about the potential for airborne irritants, allergens, pollutants, or infectious agents to n...

  6. Indoor Air Quality and Disease

    EPA Science Inventory

    Concern over the quality of indoor (i.e., residential) as well as outdoor (i.e., environmental) air is increasing. Accordingly, owners of companion animals may approach their veterinarian about the potential for airborne irritants, allergens, pollutants, or infectious agents to n...

  7. Composition of PM2.5 and PM1 on high and low pollution event days and its relation to indoor air quality in a home for the elderly.

    PubMed

    Buczyńska, Anna J; Krata, Agnieszka; Van Grieken, Rene; Brown, Andrew; Polezer, Gabriela; De Wael, Karolien; Potgieter-Vermaak, Sanja

    2014-08-15

    Many studies probing the link between air quality and health have pointed towards associations between particulate matter (PM) exposure and decreased lung function, aggravation of respiratory diseases like asthma, premature death and increased hospitalisation admissions for the elderly and individuals with cardiopulmonary diseases. Of recent, it is believed that the chemical composition and physical properties of PM may contribute significantly to these adverse health effects. As part of a Belgian Science Policy project ("Health effects of particulate matter in relation to physical-chemical characteristics and meteorology"), the chemical composition (elemental and ionic compositions) and physical properties (PM mass concentrations) of PM were investigated, indoors and outdoors of old age homes in Antwerp. The case reported here specifically relates to high versus normal/low pollution event periods. PM mass concentrations for PM1 and PM2.5 fractions were determined gravimetrically after collection via impaction. These same samples were hence analysed by EDXRF spectrometry and IC for their elemental and ionic compositions, respectively. During high pollution event days, PM mass concentrations inside the old age home reached 53 μg m(-3) and 32 μg m(-3) whilst outside concentrations were 101 μg m(-3) and 46 μg m(-3) for PM2.5 and PM1, respectively. The sum of nss-sulphate, nitrate and ammonium, dominate the composition of PM, and contribute the most towards an increase in the PM during the episode days constituting 64% of ambient PM2.5 (52 μg m(-3)) compared to 39% on non-episode days (10 μg m(-3)). Other PM components, such as mineral dust, sea salt or heavy metals were found to be considerably higher during PM episodes but relatively less important. Amongst heavy metals Zn and Pb were found at the highest concentrations in both PM2.5 and PM1. Acid-base ionic balance equations were calculated and point to acidic aerosols during event days and acidic to alkaline

  8. 32 CFR 989.30 - Air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Air quality. 989.30 Section 989.30 National... ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.30 Air quality. Section 176(c) of the Clean Air Act..., Air Quality Compliance. 10 10 See footnote 1 to § 989.1....

  9. 32 CFR 989.30 - Air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Air quality. 989.30 Section 989.30 National... ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.30 Air quality. Section 176(c) of the Clean Air Act..., Air Quality Compliance. 10 10 See footnote 1 to § 989.1....

  10. 32 CFR 989.30 - Air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Air quality. 989.30 Section 989.30 National... ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.30 Air quality. Section 176(c) of the Clean Air Act..., Air Quality Compliance. 10 10 See footnote 1 to § 989.1....

  11. 32 CFR 989.30 - Air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Air quality. 989.30 Section 989.30 National... ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.30 Air quality. Section 176(c) of the Clean Air Act..., Air Quality Compliance. 10 10 See footnote 1 to § 989.1....

  12. 32 CFR 989.30 - Air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Air quality. 989.30 Section 989.30 National... ENVIRONMENTAL IMPACT ANALYSIS PROCESS (EIAP) § 989.30 Air quality. Section 176(c) of the Clean Air Act..., Air Quality Compliance. 10 10 See footnote 1 to § 989.1....

  13. Community Multi-scale Air Quality (CMAQ) Modeling System for Air Quality Management

    EPA Pesticide Factsheets

    CMAQ simultaneously models multiple air pollutants including ozone, particulate matter and a variety of air toxics to help air quality managers determine the best air quality management scenarios for their communities, regions and states.

  14. Managing Air Quality - Air Pollutant Types

    EPA Pesticide Factsheets

    Describes the types of air pollutants, including common or criteria pollutants, and hazardous air pollutants and links to additional information. Also links to resources on other air pollution issues.

  15. Indoor Air Quality in Schools: Clean Air Is Good Business.

    ERIC Educational Resources Information Center

    Guarneiri, Michele A.

    2003-01-01

    Describes the effect of poor indoor air quality (IAQ) on student health, the cost of safeguarding good IAQ, the cause of poor IAQ in schools, how to tell whether a school has an IAQ problem, and how the U.S. Environmental Protection Agency can help schools improve indoor air quality though the use of their free "Indoor Air Quality Tools for…

  16. Indoor Air Quality in Schools: Clean Air Is Good Business.

    ERIC Educational Resources Information Center

    Guarneiri, Michele A.

    2003-01-01

    Describes the effect of poor indoor air quality (IAQ) on student health, the cost of safeguarding good IAQ, the cause of poor IAQ in schools, how to tell whether a school has an IAQ problem, and how the U.S. Environmental Protection Agency can help schools improve indoor air quality though the use of their free "Indoor Air Quality Tools for…

  17. 78 FR 10589 - Revision of Air Quality Implementation Plan; California; Sacramento Metropolitan Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-14

    ... AGENCY 40 CFR Part 52 Revision of Air Quality Implementation Plan; California; Sacramento Metropolitan Air Quality Management District; Stationary Source Permits AGENCY: Environmental Protection Agency... by California as a revision to the Sacramento Metropolitan Air Quality Management District (SMAQMD...

  18. Nursing home care quality: insights from a Bayesian network approach.

    PubMed

    Goodson, Justin; Jang, Wooseung; Rantz, Marilyn

    2008-06-01

    The purpose of this research is twofold. The first purpose is to utilize a new methodology (Bayesian networks) for aggregating various quality indicators to measure the overall quality of care in nursing homes. The second is to provide new insight into the relationships that exist among various measures of quality and how such measures affect the overall quality of nursing home care as measured by the Observable Indicators of Nursing Home Care Quality Instrument. In contrast to many methods used for the same purpose, our method yields both qualitative and quantitative insight into nursing home care quality. We construct several Bayesian networks to study the influences among factors associated with the quality of nursing home care; we compare and measure their accuracy against other predictive models. We find the best Bayesian network to perform better than other commonly used methods. We also identify key factors, including number of certified nurse assistant hours, prevalence of bedfast residents, and prevalence of daily physical restraints, that significantly affect the quality of nursing home care. Furthermore, the results of our analysis identify their probabilistic relationships. The findings of this research indicate that nursing home care quality is most accurately represented through a mix of structural, process, and outcome measures of quality. We also observe that the factors affecting the quality of nursing home care collectively determine the overall quality. Hence, focusing on only key factors without addressing other related factors may not substantially improve the quality of nursing home care.

  19. Guide to Air Cleaners in the Home

    MedlinePlus

    ... Removal Pollutant Destruction UVGI Cleaners PCO Cleaners Ozone Generators How is the Performance of an Air Cleaner ... buildings. Under Federal pesticide law, manufacturers of ozone generators must list an EPA establishment number on the ...

  20. Local Air Quality Conditions and Forecasts

    MedlinePlus

    ... 0 - 50) Air quality is considered satisfactory, and air pollution poses little or no risk. AQI: Moderate (51 - ... number of people who are unusually sensitive to air pollution. AQI: Unhealthy for Sensitive Groups (101 - 150) Although ...

  1. Ozone, Air Quality, and Asthma (For Parents)

    MedlinePlus

    ... How Poor Air Quality Affects People With Asthma Air pollution is a problem for everyone — not just people ... asthma. Studies have shown that high levels of air pollution can be associated with decreased lung function and ...

  2. [Quality assurance and total quality management in residential home care].

    PubMed

    Nübling, R; Schrempp, C; Kress, G; Löschmann, C; Neubart, R; Kuhlmey, A

    2004-02-01

    Quality, quality assurance, and quality management have been important topics in residential care homes for several years. However, only as a result of reform processes in the German legislation (long-term care insurance, care quality assurance) is a systematic discussion taking place. Furthermore, initiatives and holistic model projects, which deal with the assessment and improvement of service quality, were developed in the field of care for the elderly. The present article gives a critical overview of essential developments. Different comprehensive approaches such as the implementation of quality management systems, nationwide expert-based initiatives, and developments towards professionalizing care are discussed. Empirically based approaches, especially those emphasizing the assessment of outcome quality, are focused on in this work. Overall, the authors conclude that in the past few years comprehensive efforts have been made to improve the quality of care. However, the current situation still requires much work to establish a nationwide launch and implementation of evidence-based quality assurance and quality management.

  3. Fundamentals of Indoor Air Quality in Buildings

    EPA Pesticide Factsheets

    This module provides the fundamentals to understanding indoor air quality. It provides a rudimentary framework for understanding how indoor and outdoor sources of pollution affect the indoor air quality of buildings.

  4. Federal Interagency Committee on Indoor Air Quality

    EPA Pesticide Factsheets

    The Federal Interagency Committee on Indoor Air Quality (CIAQ), which meets three times a year, was established by Congress to coordinate the activities of the Federal Government on issues relating to Indoor Air Quality.

  5. SPATIAL PREDICTION OF AIR QUALITY DATA

    EPA Science Inventory

    Site-specific air quality monitoring data have been used extensively in both scientific and regulatory programs. As such, these data provide essential information to the public, environmental managers, and the atmospheric research community. Currently, air quality management prac...

  6. SPATIAL PREDICTION OF AIR QUALITY DATA

    EPA Science Inventory

    Site-specific air quality monitoring data have been used extensively in both scientific and regulatory programs. As such, these data provide essential information to the public, environmental managers, and the atmospheric research community. Currently, air quality management prac...

  7. 30 CFR 75.321 - Air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away...

  8. 30 CFR 75.321 - Air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away...

  9. 30 CFR 75.321 - Air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away...

  10. 30 CFR 75.321 - Air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away...

  11. 30 CFR 75.321 - Air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air quality. 75.321 Section 75.321 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.321 Air quality. (a)(1) The air in areas where... air current in these areas shall be sufficient to dilute, render harmless, and carry away...

  12. OBRA 1987 and the quality of nursing home care.

    PubMed

    Kumar, Virender; Norton, Edward C; Encinosa, William E

    2006-03-01

    Because minimum government standards for quality regulate only part of the market failure, they may have unintended effects. We present a general theory of how government regulation of quality of care may affect different market segments, and test the hypotheses for the nursing home market. OBRA 1987 was a sweeping government reform to improve the quality of nursing home care. We study how the effect of OBRA on the quality of nursing home care, measured by resident outcomes, varied with nursing home profitability. Using a semi-parametric method to control for the endogenous effects of regulation, we found that this landmark legislation had a negative effect on the quality of care in less profitable nursing homes, but improved the quality in more profitable nursing homes during the initial period after OBRA. But, this legislation had no statistically significant effect in the later period when the regulation was weakly enforced.

  13. Indoor Air Quality in Chemistry Laboratories.

    ERIC Educational Resources Information Center

    Hays, Steve M.

    This paper presents air quality and ventilation data from an existing chemical laboratory facility and discusses the work practice changes implemented in response to deficiencies in ventilation. General methods for improving air quality in existing laboratories are presented and investigation techniques for characterizing air quality are…

  14. Workshop on indoor air quality research needs

    SciTech Connect

    Not Available

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

  15. Quality of Care in Teaching Nursing Homes: Findings and Implications

    PubMed Central

    Shaughnessy, Peter W.; Kramer, Andrew M.; Hittle, David F.; Steiner, John F.

    1995-01-01

    This article explores policy implications and selected methodological topics relating to long-term care (LTC) quality. We first discuss the Teaching Nursing Home Program (TNHP), in which quality of care in teaching nursing homes (TNHs) was found to be superior to the quality of care in comparison nursing homes (CNHs). A combination of outcome and process/structural measures was used to evaluate the effects of care and underlying reasons for superior TNH outcomes. Second, we explore policy and analytic ramifications. Conceptual, methodological, and applied issues in measuring and improving the quality of LTC are discussed in the context of TNH research and related research in home care. PMID:10151895

  16. Rurality and Nursing Home Quality: Evidence from the 2004 National Nursing Home Survey

    ERIC Educational Resources Information Center

    Kang, Yu; Meng, Hongdao; Miller, Nancy A.

    2011-01-01

    Purpose of the Study: To evaluate the impact of rural geographic location on nursing home quality of care in the United States. Design and Methods: The study used cross-sectional observational design. We obtained resident- and facility-level data from 12,507 residents in 1,174 nursing homes from the 2004 National Nursing Home Survey. We used…

  17. Rurality and Nursing Home Quality: Evidence from the 2004 National Nursing Home Survey

    ERIC Educational Resources Information Center

    Kang, Yu; Meng, Hongdao; Miller, Nancy A.

    2011-01-01

    Purpose of the Study: To evaluate the impact of rural geographic location on nursing home quality of care in the United States. Design and Methods: The study used cross-sectional observational design. We obtained resident- and facility-level data from 12,507 residents in 1,174 nursing homes from the 2004 National Nursing Home Survey. We used…

  18. Nursing Home Staffing and Quality under the Nursing Home Reform Act

    ERIC Educational Resources Information Center

    Zhang, Xinzhi; Grabowski, David C.

    2004-01-01

    Purpose: We examine whether the Nursing Home Reform Act (NHRA) improved nursing home staffing and quality. Design and Methods: Data from 5,092 nursing homes were linked across the 1987 Medicare/Medicaid Automated Certification System and the 1993 Online Survey, Certification and Reporting system. A dummy-year model was used to examine the effects…

  19. Nursing Home Staffing and Quality under the Nursing Home Reform Act

    ERIC Educational Resources Information Center

    Zhang, Xinzhi; Grabowski, David C.

    2004-01-01

    Purpose: We examine whether the Nursing Home Reform Act (NHRA) improved nursing home staffing and quality. Design and Methods: Data from 5,092 nursing homes were linked across the 1987 Medicare/Medicaid Automated Certification System and the 1993 Online Survey, Certification and Reporting system. A dummy-year model was used to examine the effects…

  20. Quality of indoor residential air and health

    PubMed Central

    Dales, Robert; Liu, Ling; Wheeler, Amanda J.; Gilbert, Nicolas L.

    2008-01-01

    About 90% of our time is spent indoors where we are exposed to chemical and biological contaminants and possibly to carcinogens. These agents may influence the risk of developing nonspecific respiratory and neurologic symptoms, allergies, asthma and lung cancer. We review the sources, health effects and control strategies for several of these agents. There are conflicting data about indoor allergens. Early exposure may increase or may decrease the risk of future sensitization. Reports of indoor moulds or dampness or both are consistently associated with increased respiratory symptoms but causality has not been established. After cigarette smoking, exposure to environmental tobacco smoke and radon are the most common causes of lung cancer. Homeowners can improve the air quality in their homes, often with relatively simple measures, which should provide health benefits. PMID:18625986

  1. The Quality of Home Environment in Brazil: An Ecological Model

    ERIC Educational Resources Information Center

    de Oliveira, Ebenezer A.; Barros, Fernando C.; Anselmi, Luciana D. da Silva; Piccinini, Cesar A.

    2006-01-01

    Based on Bronfenbrenner's (1999) ecological perspective, a longitudinal, prospective model of individual differences in the quality of home environment (Home Observation for Measurement of the Environment--HOME) was tested in a sample of 179 Brazilian children and their families. Perinatal measures of family socioeconomic status (SES) and child…

  2. Ground cloud air quality effects

    NASA Technical Reports Server (NTRS)

    Brubaker, K. L.

    1980-01-01

    The effects of the ground cloud associated with launching of a large rocket on air quality are discussed. The ground cloud consists of the exhaust emitted by the rocket during the first 15 to 25 seconds following ignition and liftoff, together with a large quantity of entrained air, cooling water, dust and other debris. Immediately after formation, the ground cloud rises in the air due to the buoyant effect of its high thermal energy content. Eventually, at an altitude typically between 0.7 and 3 km, the cloud stabilizes and is carried along by the prevailing wind at that altitude. For the use of heavy lift launch vehicles small quantities of nitrogen oxides, primarily nitric oxide and nitrogen dioxide, are expected to be produced from a molecular nitrogen impurity in the fuel or liquid oxygen, or from entrainment and heating of ambient air in the hot rocket exhaust. In addition, possible impurities such as sulfur in the fuel would give rise to a corresponding amount of oxidation products such as sulfur dioxide.

  3. Creating an Asthma-Safe Home

    MedlinePlus

    ... and pollen. Improving Indoor Air Maintaining good indoor air quality in your home is an important aspect of ... for some people with asthma. To maintain good air quality inside your home: Don't allow people to ...

  4. Web screening of US nursing homes by location and quality.

    PubMed

    Pearson, Glenn; Gill, Michael; Thoma, George

    2008-11-06

    To assist American families who will one day need to find a nursing home for a loved one, NLM is developing a Web 2.0 interface to important evaluative information about nursing homes in the US. Currently in prototype form, our Nursing Home Screener locates homes on a Google Map. It allows nursing home quality, indicated by map icons, to be surveyed in any of four major categories: staffing, fire safety deficiencies, healthcare deficiencies, and quality of care inferred from residents health. Within each category, options can be tailored to user preferences. Furthermore, home attributes can be used to selectively hide home markers of less interest. The goal is to offer the public a timely, easy to use site for the rapid location and comparison of nursing homes, thus identifying those worth further review or a personal visit.

  5. Environmental control: operating room air quality.

    PubMed

    Bartley, J M

    1993-01-01

    1. OR staff members should familiarize themselves with basic air handling system terminology to better manage their own environment (eg, HVAC, air changes, air balancing, HEPA filtration). A working relationship with building engineers is an important skill for the OR nurse. 2. Knowledge of the standards on which air quality in the OR is based should assist in the process of planning for improved design--as well as in monitoring existing air quality. 3. Current standards balance energy savings with air changes and high levels of filtration to achieve optimum outcomes. Recommendations from design and engineering authorities (even for implant surgery) are based on average air changes and HEPA filtration, not laminar air flow. 4. The daily, operational role of the OR staff in maintaining high air quality includes managing traffic, using low-lint barrier materials, monitoring air quality indicators, and investigating unusual variances with the engineering staff for appropriate follow-up (eg, filter changes).

  6. The relationship between advertising, price, and nursing home quality.

    PubMed

    Kash, Bita A; Miller, Thomas R

    2009-01-01

    Theoretically, nursing homes should engage in advertising for the following two reasons: (a) to improve awareness of the services offered in a particular market and (b) to signal high-quality services. In this study, we build upon results from prior studies of nursing home advertising activity, market competition, and quality. The purpose of this study was to examine the association between advertising expenses, price, and quality. We focused on answering the question: Do nursing homes use advertising and price to signal superior quality? The Texas Nursing Facilities Medicaid Cost Report, the Texas Quality Reporting System, and the Area Resource File were merged for the year 2003. We used three alternative measures of quality to improve the robustness of this exploratory analysis. Quality measures were examined using Bonferroni correlation coefficient analysis. Associations between advertising expenses and quality were evaluated using three regression models predicting quality. We also examined the association of the price of a private bed per day with quality. Advertising expenses were not associated with better nursing home quality as measured by three quality scales. The average price customers pay for one private bed per day was associated with better quality only in one of the three quality regression models. The price of nursing home care might be a better indicator of quality and necessary to increase as quality of care is improved in the nursing homes sector. Because more advertising expenditures are not necessarily associated with better quality, consumers could be mislead by advertisements and choose poor quality nursing homes. Nursing home administrators should focus on customer relationship management tools instead of expensive advertising. Relationship management tools are proven marketing techniques for the health services sector, usually less expensive than advertising, and help with staff retention and quality outcomes.

  7. Air Quality Analysis for PSD

    EPA Pesticide Factsheets

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  8. Air Pollution Emissions Overview | Air Quality Planning & ...

    EPA Pesticide Factsheets

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  9. Competition, information, and quality: Evidence from nursing homes.

    PubMed

    Zhao, Xin

    2016-09-01

    Economic theory suggests that competition and information can both be important for product quality, and yet evidence on how they may interact to affect quality is sparse. This paper estimates the impact of competition between nursing homes on their quality, and how this impact varies when consumers have better access to information. The effect of competition is identified using exogenous variation in the geographical proximity of nursing homes to their potential consumers. The change in information transparency is captured by the launch of the Five-Star Quality Rating System in 2009, which improved access to the quality information of nursing homes. We find that while the effect of competition on nursing home quality is generally rather limited, this effect becomes significantly stronger with increased information transparency. The results suggest that regulations on public quality reporting and on market structure are policy complements, and should be considered jointly to best improve quality.

  10. Quality and cost of student lunches brought from home

    USDA-ARS?s Scientific Manuscript database

    The nutritional quality and cost of lunches brought from home are overlookedand understudied aspects of the school food environment. To examine the quality and cost of lunches brought from home by elementary and intermediate school students. An observational studywas conducted in 12 schools (8 eleme...

  11. EPA Pushing Improved Air Quality in Schools.

    ERIC Educational Resources Information Center

    Sack, Joetta L.

    2002-01-01

    Discusses how, in response to the growing problem of poor air quality in schools, the Environmental Protection Agency (EPA) has set new voluntary air-quality guidelines for schools. Addresses common air-related irritants; successful efforts at Guerrero Elementary School in Mesa, Arizona; preventive maintenance; and a sample of the EPA's…

  12. EPA Pushing Improved Air Quality in Schools.

    ERIC Educational Resources Information Center

    Sack, Joetta L.

    2002-01-01

    Discusses how, in response to the growing problem of poor air quality in schools, the Environmental Protection Agency (EPA) has set new voluntary air-quality guidelines for schools. Addresses common air-related irritants; successful efforts at Guerrero Elementary School in Mesa, Arizona; preventive maintenance; and a sample of the EPA's…

  13. Air Quality Criteria for Particulate Matter.

    ERIC Educational Resources Information Center

    National Air Pollution Control Administration (DHEW), Washington, DC.

    To assist states in developing air quality standards, this book offers a review of literature related to atmospheric particulates and the development of criteria for air quality. It not only summarizes the current scientific knowledge of particulate air pollution, but points up the major deficiencies in that knowledge and the need for further…

  14. Higher prices, higher quality? Evidence from German nursing homes.

    PubMed

    Herr, Annika; Hottenrott, Hanna

    2016-02-01

    This study investigates the relationship between prices and quality of 7400 German nursing homes. We use a cross section of public quality reports for all German nursing homes, which had been evaluated between 2010 and 2013 by external institutions. Our analysis is based on multivariate regressions in a two stage least squares framework, where we instrument prices to explain their effect on quality controlling for income, nursing home density, demographics, labour market characteristics, and infrastructure at the regional level. Descriptive analysis shows that prices and quality do not only vary across nursing homes, but also across counties and federal states and that quality and prices correlate positively. Second, the econometric analysis, which accounts for the endogenous relation between negotiated price and reported quality, shows that quality indeed positively depends on prices. In addition, more places in nursing homes per people in need are correlated with both lower prices and higher quality. Finally, unobserved factors at the federal state level capture some of the variation of reported quality across nursing homes. Our results suggest that higher prices increase quality. Furthermore, since reported quality and prices vary substantially across federal states, we conclude that the quality and prices of long-term care facilities may well be compared within federal states but not across. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. 78 FR 63934 - Approval of Air Quality Implementation Plans; California; El Dorado County Air Quality Management...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... AGENCY 40 CFR Part 52 Approval of Air Quality Implementation Plans; California; El Dorado County Air... Plan (SIP) revision submitted by California for the El Dorado County Air Quality Management District... Ambient Air Quality Standards (NAAQS). We are proposing to approve the submitted SIP revision under...

  16. Quality management in home care: models for today's practice.

    PubMed

    Verhey, M P

    1996-01-01

    In less than a decade, home care providers have been a part of two major transitions in health care delivery. First, because of the advent of managed care and a shift from inpatient to community-based services, home care service delivery systems have experienced tremendous growth. Second, the principles and practices of total quality management and continuous quality improvement have permeated the organization, administration, and practice of home health care. Based on the work of Deming, Juran, and Crosby, the basic tenets of the new quality management philosophy involve a focus on the following five key areas: (1) systems and processes rather than individual performance; (2) involvement, collaboration, and empowerment; (3) internal and external "customers"; (4) data and measurement; and (5) standards, guidelines, and outcomes of care. Home care providers are among those in the forefront who are developing and implementing programs that integrate these foci into the delivery of quality home care services. This article provides a summary of current home care programs that address these five key areas of quality management philosophy and provide models for innovative quality management practice in home care. For further information about each program, readers are referred to the original reports in the home care and quality management journal literature, as cited herein.

  17. Culture change and nursing home quality of care.

    PubMed

    Grabowski, David C; O'Malley, A James; Afendulis, Christopher C; Caudry, Daryl J; Elliot, Amy; Zimmerman, Sheryl

    2014-02-01

    Culture change models are intended to improve the quality of life for nursing home residents, but the impact of these models on quality of care is unknown. We evaluated the impact of the implementation of nursing home culture change on the quality of care, as measured by staffing, health-related survey deficiencies, and Minimum Data Set (MDS) quality indicators. From the Pioneer Network, we have data on whether facilities were identified by experts as "culture change" providers in 2004 and 2009. Using administrative data, we employed a panel-based regression approach in which we compared pre-post quality outcomes in facilities adopting culture change between 2004 and 2009 against pre-post quality outcomes for a propensity score-matched comparison group of nonadopters. Nursing homes that were identified as culture change adopters exhibited a 14.6% decrease in health-related survey deficiency citations relative to comparable nonadopting homes, while experiencing no significant change in nurse staffing or various MDS quality indicators. This research represents the first large-scale longitudinal evaluation of the association of culture change and nursing home quality of care. Based on the survey deficiency results, nursing homes that were identified as culture change adopters were associated with better care although the surveyors were not blind to the nursing home's culture change efforts. This finding suggests culture change may have the potential to improve MDS-based quality outcomes, but this has not yet been observed.

  18. Air Quality Monitoring And Forecasting In China

    NASA Astrophysics Data System (ADS)

    Van Der A, Ronald; Mijling, Bas; De Smedt, Isabelle; Van Roozendael, Michel; Kelder, Hennie

    2010-10-01

    For the last decade the industrial activity of China has been growing at rapid pace, bringing economic wealth to its 1300 million inhabitants, but also generating an unprecedented level of air pollution. This deteriorates the air quality of the densely populated and industrialized areas such as Beijing, Shanghai and the Pearl River Delta, and increases the background pollution levels world-wide [1]. The AMFIC project aims at monitoring and forecasting the air quality in China by using satellite observations and model simulations, together with ground observations in China. The combination of these instruments and tools offers a unique possibility to investigate trends in air pollution and the effectiveness of air quality policy.

  19. Radon Resources for Home Buyers and Sellers

    MedlinePlus

    ... provide feedback, or report a problem. Radon Indoor Air Quality Home Page Radon Home Local Radon Zones and State Contact Information Individuals and Families Radon Publications Home Buyers and ... Air Bed Bugs Chemicals and Toxics Climate Change Environmental ...

  20. Indoor air quality: A psychosocial perspective

    SciTech Connect

    Boxer, P.A. )

    1990-05-01

    The incidence of indoor air quality problems has increased dramatically over the past decade. Investigation of these problems has yielded a definitive cause in only one third of the cases. Psychosocial factors may play a key role in the development and propagation of symptoms attributed to poor indoor air quality. Guidelines for managing indoor air quality problems from the organizational perspective are based upon psychosocial principles and elements of risk perception.

  1. Indoor air quality: a psychosocial perspective.

    PubMed

    Boxer, P A

    1990-05-01

    The incidence of indoor air quality problems has increased dramatically over the past decade. Investigation of these problems has yielded a definitive cause in only one third of the cases. Psychosocial factors may play a key role in the development and propagation of symptoms attributed to poor indoor air quality. Guidelines for managing indoor air quality problems from the organizational perspective are based upon psychosocial principles and elements of risk perception.

  2. Navajo coal and air quality in Shiprock, New Mexico

    USGS Publications Warehouse

    Bunnell, Joseph E.; Garcia, Linda V.

    2006-01-01

    Among the Navajo people, high levels of respiratory disease, such as asthma, exist in a population with low rates of cigarette smoking. Air quality outdoors and indoors affects respiratory health. Many Navajo Nation residents burn locally mined coal in their homes for heat, as coal is the most economical energy source. The U.S. Geological Survey and Dine College, in cooperation with the Navajo Division of Health, are conducting a study in the Shiprock, New Mexico, area to determine if indoor use of this coal might be contributing to some of the respiratory health problems experienced by the residents. Researchers in this study will (1) examine respiratory health data, (2) identify stove type and use, (3) analyze samples of coal that are used locally, and (4) measure and characterize air quality inside selected homes. This Fact Sheet summarizes the interim results of the study in both English and Navajo.

  3. The Economic Value of Air Quality Forecasting

    NASA Astrophysics Data System (ADS)

    Anderson-Sumo, Tasha

    Both long-term and daily air quality forecasts provide an essential component to human health and impact costs. According the American Lung Association, the estimated current annual cost of air pollution related illness in the United States, adjusted for inflation (3% per year), is approximately $152 billion. Many of the risks such as hospital visits and morality are associated with poor air quality days (where the Air Quality Index is greater than 100). Groups such as sensitive groups become more susceptible to the resulting conditions and more accurate forecasts would help to take more appropriate precautions. This research focuses on evaluating the utility of air quality forecasting in terms of its potential impacts by building on air quality forecasting and economical metrics. Our analysis includes data collected during the summertime ozone seasons between 2010 and 2012 from air quality models for the Washington, DC/Baltimore, MD region. The metrics that are relevant to our analysis include: (1) The number of times that a high ozone or particulate matter (PM) episode is correctly forecasted, (2) the number of times that high ozone or PM episode is forecasted when it does not occur and (3) the number of times when the air quality forecast predicts a cleaner air episode when the air was observed to have high ozone or PM. Our collection of data included available air quality model forecasts of ozone and particulate matter data from the U.S. Environmental Protection Agency (EPA)'s AIRNOW as well as observational data of ozone and particulate matter from Clean Air Partners. We evaluated the performance of the air quality forecasts with that of the observational data and found that the forecast models perform well for the Baltimore/Washington region and the time interval observed. We estimate the potential amount for the Baltimore/Washington region accrues to a savings of up to 5,905 lives and 5.9 billion dollars per year. This total assumes perfect compliance with

  4. Biomass fuel use and indoor air pollution in homes in Malawi

    PubMed Central

    Fullerton, D G; Semple, S; Kalambo, F; Suseno, A; Malamba, R; Henderson, G; Ayres, J G; Gordon, S B

    2009-01-01

    Background: Air pollution from biomass fuels in Africa is a significant cause of mortality and morbidity both in adults and children. The work describes the nature and quantity of smoke exposure from biomass fuel in Malawian homes. Methods: Markers of indoor air quality were measured in 62 homes (31 rural and 31 urban) over a typical 24 h period. Four different devices were used (one gravimetric device, two photometric devices and a carbon monoxide (HOBO) monitor. Gravimetric samples were analysed for transition metal content. Data on cooking and lighting fuel type together with information on indicators of socioeconomic status were collected by questionnaire. Results: Respirable dust levels in both the urban and rural environment were high with the mean (SD) 24 h average levels being 226 μg/m3 (206 μg/m3). Data from real-time instruments indicated respirable dust concentrations were >250 μg/m3 for >1 h per day in 52% of rural homes and 17% of urban homes. Average carbon monoxide levels were significantly higher in urban compared with rural homes (6.14 ppm vs 1.87 ppm; p<0.001). The transition metal content of the smoke was low, with no significant difference found between urban and rural homes. Conclusions: Indoor air pollution levels in Malawian homes are high. Further investigation is justified because the levels that we have demonstrated are hazardous and are likely to be damaging to health. Interventions should be sought to reduce exposure to concentrations less harmful to health. PMID:19671533

  5. Air Quality Monitoring and Sensor Technologies

    EPA Pesticide Factsheets

    EPA scientist Ron Williams presented on the features, examination, application, examples, and data quality of continuous monitoring study designs at EPA's Community Air Monitoring Training in July 2015.

  6. Managing Air Quality - Ongoing Evaluation of Progress

    EPA Pesticide Factsheets

    Describes the importance of evaluating if air quality programs are achieving the desired results to inform environmental program managers, regulated industry and the public, and provides EPA examples.

  7. Air Quality Index (AQI) -- A Guide to Air Quality and Your Health

    MedlinePlus

    ... the AQI value, the greater the level of air pollution and the greater the health concern. For example, ... to 50. Air quality is considered satisfactory, and air pollution poses little or no risk. "Moderate" AQI is ...

  8. Smart homes to improve the quality of life for all.

    PubMed

    Aiello, Marco; Aloise, Fabio; Baldoni, Roberto; Cincotti, Febo; Guger, Christoph; Lazovik, Alexander; Mecella, Massimo; Pucci, Paolo; Rinsma, Johanna; Santucci, Giuseppe; Taglieri, Massimiliano

    2011-01-01

    A home is smart when, being aware of its own state and that of its users, is capable of controlling itself in order to support the user wishes and thus improving their quality of life. This holds both for users with special needs and for those with ordinary domestic needs. In this paper, we overview the Smart Homes for All project which represents the current state of the art with respect to software control and user interfaces in the smart homes arena.

  9. 40 CFR 52.1929 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1929 Section 52.1929 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) Regulation for preventing significant deterioration of air... preventing significant deterioration of air quality....

  10. Biological air filter for air-quality control

    NASA Astrophysics Data System (ADS)

    van Ras, Niels; Krooneman, Janneke; Ogink, Nico; Willers, Hans; D'Amico, Arnaldo; di Natale, Corrado; Godia, F.; Albiol, J.; Perez, J.; Martinez, N.; Dixon, Mike; Llewellyn, David; Eckhard, Fir; Zona, G.; Fachecci, L.; Kraakman, Bart; Demey, Dries; Michel, Noelle; Darlington, Alan

    2005-10-01

    Biological air filtration is a promising technique for air-quality control in closed environments in space and on Earth, and it offers several advantages over existing techniques. However, to apply it in these environments, specific criteria have to be met. A concept for biological air filtration in closed environments was developed and tested by an international team of specialists. Several model systems for closed environments in space and on Earth were used as a source of contaminated air. Conventional and new analytical techniques were used to determine odour composition and removal efficiency of the filter, including an "electronic nose". The results show that the developed biological air filter is suitable for treating contaminated air in closed environments. The developed electronic nose was shown to be a promising method for air-quality monitoring.

  11. Nursing Home Staff Turnover: Impact on Nursing Home Compare Quality Measures

    ERIC Educational Resources Information Center

    Castle, Nicholas G.; Engberg, John; Men, Aiju

    2007-01-01

    Purpose: We used data from a large sample of nursing homes to examine the association between staff turnover and quality. Design and Methods: The staff turnover measures came from primary data collected from 2,840 nursing homes in 2004 (representing a 71% response rate). Data collection included measures for nurse aides, licensed practical nurses,…

  12. Use of Clinical Health Information Technology in Nursing Homes: Nursing Home Characteristics and Quality Measures

    ERIC Educational Resources Information Center

    Spinelli-Moraski, Carla

    2014-01-01

    This study compares quality measures among nursing homes that have adopted different levels of clinical health information technology (HIT) and examines the perceived barriers and benefits of the adoption of electronic health records as reported by Nursing Home Administrators and Directors of Nursing. A cross-sectional survey distributed online to…

  13. Nursing Home Staff Turnover: Impact on Nursing Home Compare Quality Measures

    ERIC Educational Resources Information Center

    Castle, Nicholas G.; Engberg, John; Men, Aiju

    2007-01-01

    Purpose: We used data from a large sample of nursing homes to examine the association between staff turnover and quality. Design and Methods: The staff turnover measures came from primary data collected from 2,840 nursing homes in 2004 (representing a 71% response rate). Data collection included measures for nurse aides, licensed practical nurses,…

  14. 78 FR 30770 - Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air Quality Standards...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-23

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air... National Ambient Air Quality Standards (NAAQS) for ozone and particulate matter (PM). EPA is approving a... Implementation Plan at 35 Illinois Administrative Code part 243, which updates National Ambient Air...

  15. Air quality monitor and acid rain networks

    NASA Technical Reports Server (NTRS)

    Rudolph, H.

    1980-01-01

    The air quality monitor program which consists of two permanent air monitor stations (PAMS's) and four mobile shuttle pollutant air monitor stations (SPAMS's) is evaluated. The PAMS measures SO sub X, NO sub X particulates, CO, O3, and nonmethane hydrocarbons. The SPAMS measures O3, SO2, HCl, and particulates. The collection and analysis of data in the rain monitor program are discussed.

  16. Biodiversity, air quality and human health

    Treesearch

    David J. Nowak; Sarah Jovan; Christina Branquinho; Sofia Augusto; Manuel C. Ribeiro; Conor E. Kretsch

    2015-01-01

    Air pollution is a significant problem in cities across the world. It affects human health and well-being, ecosystem health, crops, climate, visibility and human-made materials. Health effects related to air pollution include its impact on the pulmonary, cardiac, vascular and neurological systems (Section 2). Trees affect air quality through a number of means (Section...

  17. Air quality on biomass harvesting operations

    Treesearch

    Dana Mitchell

    2011-01-01

    The working environment around logging operations can be very dusty. But, air quality around logging operations is not well documented. Equipment movements and trafficking on the landing can cause dust to rise into the air. The addition of a biomass chipper creates different air flow patterns and may stir up additional dust. This project addresses two topics related to...

  18. 75 FR 65594 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-26

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY... consolidation of Ohio's Ambient Air Quality Standards (AAQS) into Ohio's State Implementation Plan (SIP)...

  19. 78 FR 30829 - Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air Quality Standards...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-23

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air Quality Standards Revision AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY... current national ambient air quality standards (NAAQS) for ozone, lead, and particulate matter. EPA...

  20. 75 FR 65572 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-26

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Direct final rule... of Ohio's Ambient Air Quality Standards (AAQS) into Ohio's State Implementation Plan (SIP) under...

  1. 78 FR 19990 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards; Correction AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule... air quality standards in a new chapter of rules and adjusted the rule references accordingly...

  2. Current Indoor Air Quality in Japan.

    PubMed

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  3. Breaking the Mold on Air Quality.

    ERIC Educational Resources Information Center

    NEA Today, 2001

    2001-01-01

    Indoor air quality is a growing problem in aging school buildings. The Environmental Protection Agency (EPA) offers an Indoor Air Quality Tools for Schools kit which is being used at schools nationwide to improve school maintenance. Profiles an aging school in Connecticut in which teachers were becoming ill to illustrate the use of the kit to…

  4. Air Quality Measurements for Science and Policy

    EPA Science Inventory

    Air quality measurements and the methods used to conduct them are vital to advancing our knowledge of the source-to-receptor-to-health effects continuum1-3. This information then forms the basis for evaluating and managing air quality to protect human health and welfa...

  5. Agricultural Air Quality: A USDA Perspective

    USDA-ARS?s Scientific Manuscript database

    Agricultural air quality concerns have broadened recently because of the increasing urban-rural interface; greater understanding of the impact of air quality on health, visibility and safety, and coincident regulation increases; and increasing size and density of some farming operations. The USDA h...

  6. Indoor Air Quality: Maryland Public Schools.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Education, College Park. Office of Administration and Finance.

    Less than adequate indoor air quality in schools can lead to a higher risk of health problems, an increase in student and teacher absenteeism, diminished learning, and even hazardous conditions. An indoor air quality program that addresses the planning, design, maintenance, and operation of public school buildings should be implemented at the…

  7. Source Emissions in Multipollutant Air Quality Management

    EPA Science Inventory

    Human activities and natural processes that emit pollutants into the ambient atmosphere are the underlying cause of all air quality problems. In a technical sense, we refer to these activities and processes as pollutant sources. Although air quality management is usually concerne...

  8. FORECASTING AIR QUALITY OVER THE UNITED STATES

    EPA Science Inventory

    Increased awareness of national air quality issues on the part of the media and the general public have recently led to more demand for short-term (1-2 day) air quality forecasts for use in assessing potential health impacts (e.g., on children, the elderly, and asthmatics) and po...

  9. Indoor Air Quality: A Guide for Educators.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    Indoor air quality is a major concern for educators involved in the development of new school facilities, or the remodeling and maintenance of existing ones. This guide addresses the issue of air quality, the health concerns involved, and procedures for minimizing the impact of pollutants in the school environment. It defines common indoor air…

  10. 40 CFR 240.205 - Air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Air quality. 240.205 Section 240.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures § 240.205 Air quality....

  11. 40 CFR 240.205 - Air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Air quality. 240.205 Section 240.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures § 240.205 Air quality....

  12. 40 CFR 240.205 - Air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Air quality. 240.205 Section 240.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures § 240.205 Air quality....

  13. 40 CFR 240.205 - Air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Air quality. 240.205 Section 240.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures § 240.205 Air quality....

  14. Breaking the Mold on Air Quality.

    ERIC Educational Resources Information Center

    NEA Today, 2001

    2001-01-01

    Indoor air quality is a growing problem in aging school buildings. The Environmental Protection Agency (EPA) offers an Indoor Air Quality Tools for Schools kit which is being used at schools nationwide to improve school maintenance. Profiles an aging school in Connecticut in which teachers were becoming ill to illustrate the use of the kit to…

  15. 40 CFR 240.205 - Air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Air quality. 240.205 Section 240.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures § 240.205 Air quality....

  16. FORECASTING AIR QUALITY OVER THE UNITED STATES

    EPA Science Inventory

    Increased awareness of national air quality issues on the part of the media and the general public have recently led to more demand for short-term (1-2 day) air quality forecasts for use in assessing potential health impacts (e.g., on children, the elderly, and asthmatics) and po...

  17. Communicating Instantaneous Air Quality Data: Pilot Project

    EPA Pesticide Factsheets

    Communicating Instantaneous Air Quality Data: Pilot ProjectEPA is launching a pilot project to test a new tool for making instantaneous outdoor air quality data useful for the public. The new “sensor scale” is designed to be used with sensors

  18. Source Emissions in Multipollutant Air Quality Management

    EPA Science Inventory

    Human activities and natural processes that emit pollutants into the ambient atmosphere are the underlying cause of all air quality problems. In a technical sense, we refer to these activities and processes as pollutant sources. Although air quality management is usually concerne...

  19. Air Quality Measurements for Science and Policy

    EPA Science Inventory

    Air quality measurements and the methods used to conduct them are vital to advancing our knowledge of the source-to-receptor-to-health effects continuum1-3. This information then forms the basis for evaluating and managing air quality to protect human health and welfa...

  20. Blending Key Ingredients to Assure Quality in Home Health Care.

    ERIC Educational Resources Information Center

    Griffith, Deloris G.

    1986-01-01

    Careful staff selection, training, and review are among the methods the author recommends to home care agencies striving to provide top-notch services. Discusses measuring the quality of care employees are providing, accreditation, and the benefits of accreditation. (CT)

  1. Nursing Home Care Quality: Insights from a Bayesian Network Approach

    ERIC Educational Resources Information Center

    Goodson, Justin; Jang, Wooseung; Rantz, Marilyn

    2008-01-01

    Purpose: The purpose of this research is twofold. The first purpose is to utilize a new methodology (Bayesian networks) for aggregating various quality indicators to measure the overall quality of care in nursing homes. The second is to provide new insight into the relationships that exist among various measures of quality and how such measures…

  2. Nursing Home Care Quality: Insights from a Bayesian Network Approach

    ERIC Educational Resources Information Center

    Goodson, Justin; Jang, Wooseung; Rantz, Marilyn

    2008-01-01

    Purpose: The purpose of this research is twofold. The first purpose is to utilize a new methodology (Bayesian networks) for aggregating various quality indicators to measure the overall quality of care in nursing homes. The second is to provide new insight into the relationships that exist among various measures of quality and how such measures…

  3. Air quality risk assessment and management.

    PubMed

    Chen, Yue; Craig, Lorraine; Krewski, Daniel

    2008-01-01

    This article provides (1) a synthesis of the literature on the linkages between air pollution and human health, (2) an overview of quality management approaches in Canada, the United States, and the European Union (EU), and (3) future directions for air quality research. Numerous studies examining short-term effects of air pollution show significant associations between ambient levels of particulate matter (PM) and other air pollutants and increases in premature mortality and hospitalizations for cardiovascular and respiratory illnesses. Several well-designed epidemiological studies confirmed the adverse long-term effects of PM on both mortality and morbidity. Epidemiological studies also document significant associations between ozone (O3), sulfur (SO2), and nitrogen oxides (NO(x)) and adverse health outcomes; however, the effects of gaseous pollutants are less well documented. Subpopulations that are more susceptible to air pollution include children, the elderly, those with cardiorespiratory disease, and socioeconomically deprived individuals. Canada-wide standards for ambient air concentrations of PM2.5 and O3 were set in 2000, providing air quality targets to be achieved by 2010. In the United States, the Clean Air Act provides the framework for the establishment and review of National Ambient Air Quality Standards for criteria air pollutants and the establishment of emissions standards for hazardous air pollutants. The 1996 European Union's enactment of the Framework Directive for Air Quality established the process for setting Europe-wide limit values for a series of pollutants. The Clean Air for Europe program was established by the European Union to review existing limit values, emission ceilings, and abatement protocols, as set out in the current legislation. These initiatives serve as the legislative framework for air quality management in North America and Europe.

  4. Air Quality Monitoring: Risk-Based Choices

    NASA Technical Reports Server (NTRS)

    James, John T.

    2009-01-01

    Air monitoring is secondary to rigid control of risks to air quality. Air quality monitoring requires us to target the credible residual risks. Constraints on monitoring devices are severe. Must transition from archival to real-time, on-board monitoring. Must provide data to crew in a way that they can interpret findings. Dust management and monitoring may be a major concern for exploration class missions.

  5. Protocols for Home Energy Upgrades

    EPA Pesticide Factsheets

    Remodeling or renovating an existing home not only has the potential to release pollutants into the home; it is also an opportunity to make changes that will improve the indoor air quality in your home.

  6. Enhancing indoor air quality -The air filter advantage.

    PubMed

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  7. Enhancing indoor air quality –The air filter advantage

    PubMed Central

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality. PMID:26628762

  8. Air Quality | Air Quality Planning & Standards | US EPA

    EPA Pesticide Factsheets

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  9. Managing Air Quality - Control Strategies to Achieve Air Pollution Reduction

    EPA Pesticide Factsheets

    Considerations in designing an effective control strategy related to air quality, controlling pollution sources, need for regional or national controls, steps to developing a control strategy, and additional EPA resources.

  10. Parameters affecting air infiltration and air tightness in thirty-one east Tennessee homes

    SciTech Connect

    Gammage, R.B.; Hawthorne, A.R.; White, D.A.

    1984-04-03

    A major pathway for loss of conditioned air in east Tennessee homes with externally located heating, ventilation, and air-conditioning (HVAC) systems is leakage in the ductwork. The effect on infiltration rates, as measured by Freon-12 tracer gas dilution, becomes marked if the central duct fan is operating; duct-fan on and duct-fan off measurements of the rate of air exchange gave mean values of 0.41 and 0.78 h/sup -1/, respectively, in a total of 31 homes. Specific leakage areas measured by the blower-door, pressurization-depressurization technique are affected to a lesser extent by inclusion of the ductwork volume within the total volume of the house that is being pressurized. A subset of 7 of the study homes were measured using this technique; the average increment in the specific leakage area was about 15%. In dealing with homes that have central HVAC systems, weatherization and energy conservation programs should be cognizant of the seriousness of air and energy losses caused by leaking ductwork. 8 references, 2 tables.

  11. Manual on indoor air quality. Final report. [Glossary

    SciTech Connect

    Diamond, R.C.; Grimsrud, D.T.

    1984-02-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. 112 references, 19 figures, 13 tables.

  12. Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits

    SciTech Connect

    Less, Brennan; Walker, Iain

    2014-06-01

    Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr-1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 μg/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 μg/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

  13. Air Leakage of U.S. Homes: Model Prediction

    SciTech Connect

    Sherman, Max H.; McWilliams, Jennifer A.

    2007-01-01

    Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. The Lawrence Berkeley National Laboratory has been gathering residential air leakage data from many sources and now has a database of more than 100,000 raw measurements. This paper uses a model developed from that database in conjunction with US Census Bureau data for estimating air leakage as a function of location throughout the US.

  14. Organizational determinants of service quality in nursing homes.

    PubMed

    Steffen, T M; Nystrom, P C

    1997-01-01

    This study analyzed four prominent organizational factors thought to influence service quality in nursing homes. Perceptions of service quality were collected from over 400 family members who regularly visited residents in 41 nursing homes. Service quality was measured along five dimensions identified by marketing research on customers in service industries. These five dimensions were responsiveness, reliability, assurance, empathy, and tangibles. Perceptions of service quality exhibited significant associations with each of the four organizational factors: ownership, funding mix, facility size, and nurse staffing. Implications for health services administration are discussed.

  15. Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems & Indoor Air Quality - Exhaust Fan Mitigation.

    SciTech Connect

    United States. Bonneville Power Administration.

    1987-07-01

    Overall, the findings show that exhaust fans basically provide small amounts of ventilation compensation. By monitoring the common indoor air pollutants (radon, formaldehyde, carbon monoxide, nitrogen dioxide, and water vapor), it was found that the quality of the indoor air was not adversely affected by the use of exhaust fans. Nor did their use provide any measurable or significant benefits since no improvement in air quality was ascertained. While exhaust fans of this small size did not increase radon, which is the contaminant of most concern, the researchers caution that operation of a larger fan or installation in a very tight home could result in higher levels because depressurization is greater. The daily energy consumption for use of these appliances during the heating season was calculated to be 1.5 kilowatt hours or approximately 3% of the energy consumption in the study homes. The information collected in this collaborative field study indicates that the use of these particular ventilation systems has no significant effect on indoor air quality.

  16. Deep learning architecture for air quality predictions.

    PubMed

    Li, Xiang; Peng, Ling; Hu, Yuan; Shao, Jing; Chi, Tianhe

    2016-11-01

    With the rapid development of urbanization and industrialization, many developing countries are suffering from heavy air pollution. Governments and citizens have expressed increasing concern regarding air pollution because it affects human health and sustainable development worldwide. Current air quality prediction methods mainly use shallow models; however, these methods produce unsatisfactory results, which inspired us to investigate methods of predicting air quality based on deep architecture models. In this paper, a novel spatiotemporal deep learning (STDL)-based air quality prediction method that inherently considers spatial and temporal correlations is proposed. A stacked autoencoder (SAE) model is used to extract inherent air quality features, and it is trained in a greedy layer-wise manner. Compared with traditional time series prediction models, our model can predict the air quality of all stations simultaneously and shows the temporal stability in all seasons. Moreover, a comparison with the spatiotemporal artificial neural network (STANN), auto regression moving average (ARMA), and support vector regression (SVR) models demonstrates that the proposed method of performing air quality predictions has a superior performance.

  17. Perceived indoor air quality and its relationship to air pollutants in French dwellings.

    PubMed

    Langer, S; Ramalho, O; Le Ponner, E; Derbez, M; Kirchner, S; Mandin, C

    2017-05-05

    Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM10 and PM2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    PubMed

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  19. Home care aide evaluation. Assuring competency & quality.

    PubMed

    Twardon, C; Cherry, C; Gartner, M

    1992-04-01

    Supervision and evaluation of the direct care provider can be a costly and time-consuming activity. A comprehensive process to coordinate the various aspects of the home care aide evaluation is a creative solution for the efficient use of supervisory and staff time, paperwork reduction, and cost containment.

  20. Breathing Easy over Air Quality.

    ERIC Educational Resources Information Center

    Greim, Clifton; Turner, William

    1991-01-01

    School systems should test the air in every school building for the presence and level of contaminants such as radon and asbestos and whether the ventilation system is circulating the proper amount of air. Periodic maintenance is required for all mechanical systems. (MLF)

  1. Breathing Easy over Air Quality.

    ERIC Educational Resources Information Center

    Greim, Clifton; Turner, William

    1991-01-01

    School systems should test the air in every school building for the presence and level of contaminants such as radon and asbestos and whether the ventilation system is circulating the proper amount of air. Periodic maintenance is required for all mechanical systems. (MLF)

  2. Predicting Air Quality in Smart Environments

    PubMed Central

    Deleawe, Seun; Kusznir, Jim; Lamb, Brian; Cook, Diane J.

    2011-01-01

    The pervasive sensing technologies found in smart environments offer unprecedented opportunities for monitoring and assisting the individuals who live and work in these spaces. As aspect of daily life that is often overlooked in maintaining a healthy lifestyle is the air quality of the environment. In this paper we investigate the use of machine learning technologies to predict CO2 levels as an indicator of air quality in smart environments. We introduce techniques for collecting and analyzing sensor information in smart environments and analyze the correlation between resident activities and air quality levels. The effectiveness of our techniques is evaluated using three physical smart environment testbeds. PMID:21617739

  3. Comparing Public Quality Ratings for Accredited and Nonaccredited Nursing Homes.

    PubMed

    Williams, Scott C; Morton, David J; Braun, Barbara I; Longo, Beth Ann; Baker, David W

    2017-01-01

    Compare quality ratings of accredited and nonaccredited nursing homes using the publicly available Centers for Medicare and Medicaid Services (CMS) Nursing Home Compare data set. This cross-sectional study compared the performance of 711 Joint Commission-accredited (TJC-accredited) nursing homes (81 of which also had Post-Acute Care Certification) to 14,926 non-Joint Commission-accredited (non-TJC-accredited) facilities using the Nursing Home Compare data set (as downloaded on April 2015). Measures included the overall Five-Star Quality Rating and its 4 components (health inspection, quality measures, staffing, and RN staffing), the 18 Nursing Home Compare quality measures (5 short-stay measures, 13 long-stay measures), as well as inspection deficiencies, fines, and payment denials. t tests were used to assess differences in rates for TJC-accredited nursing homes versus non-TJC-accredited nursing homes for quality measures, ratings, and fine amounts. Analysis of variance models were used to determine differences in rates using Joint Commission accreditation status, nursing home size based on number of beds, and ownership type. An additional model with an interaction term using Joint Commission accreditation status and Joint Commission Post-Acute Care Certification status was used to determine differences in rates for Post-Acute Care Certified nursing homes. Binary variables (eg, deficiency type, fines, and payment denials) were evaluated using a logistic regression model with the same covariates. After controlling for the influences of facility size and ownership type, TJC-accredited nursing homes had significantly higher star ratings than non-TJC-accredited nursing homes on each of the star rating component subscales (P < .05) (but not on the overall star rating), and TJC-accredited nursing homes with Post-Acute Care Certification performed statistically better on the overall star rating, as well as 3 of the 4 subscales (P < .05). TJC-accredited nursing homes

  4. Home safety and low-income urban housing quality.

    PubMed

    Gielen, Andrea C; Shields, Wendy; McDonald, Eileen; Frattaroli, Shannon; Bishai, David; Ma, Xia

    2012-12-01

    Living in substandard housing may be one factor that increases the risk of fire and burn injuries in low-income urban environments. The purposes of this study are to (1) describe the frequency and characteristics of substandard housing in urban homes with young children and (2) explore the hypothesis that better housing quality is associated with a greater likelihood of having working smoke alarms and safe hot water temperatures. A total 246 caregivers of children ages 0 to 7 years were recruited from a pediatric emergency department and a well-child clinic. In-home observations were completed by using 46 items from the Housing and Urban Development's Housing Quality Standards. Virtually all homes (99%) failed the housing quality measure. Items with the highest failure rates were those related to heating and cooling; walls, ceilings, and floors; and sanitation and safety domains. One working smoke alarm was observed in 82% of the homes, 42% had 1 on every level, and 62% had safe hot water temperatures. For every increase of 1 item in the number of housing quality items passed, the odds of having any working smoke alarm increased by 10%, the odds of having 1 on every level by 18%, and the odds of having safe hot water temperatures by 8%. Many children may be at heightened risk for fire and scald burns by virtue of their home environment. Stronger collaboration between housing, health care, and injury prevention professionals is urgently needed to maximize opportunities to improve home safety.

  5. Proactive management of air quality.

    PubMed

    Angle, R P; Sandhu, H S

    2001-02-01

    Traditional air resource management systems have difficulty in addressing global issues, sustainable development, direct citizen participation, and integration with broad economic interests. As reactive management systems, they tend to be compliance-driven, static, and rigid. In contrast, proactive management systems are principle-driven, innovative, and flexible. Bridge scientists play a key role in supporting the transformation of raw data into wise action. Decision-makers need to integrate social values with knowledge about emissions, atmospheric processes, and potential environmental effects using the primary tools of measurements, monitoring, and modeling. The Alberta Clean Air Strategic Alliance, a unique partnership of governments, industry, and public interest groups formed in 1994, operates a comprehensive air management system that is capable of addressing air issues of greater complexity and uncertainty. Its success is measured by the satisfaction of its diverse stakeholders and by the number and scope of its initiatives. Copyright 2001 Springer-Verlag

  6. The Search for a Permanent Home: Explaining the Organizational Instability of Air Force Rescue

    DTIC Science & Technology

    2015-06-01

    The Search for a Permanent Home: Explaining the Organizational Instability of Air Force Rescue BY Major Mark Uberuaga A THESIS...SPACE STUDIES AIR UNIVERSITY MAXWELL AIR FORCE BASE, ALABAMA JUNE 2015 DISTRIBUTION A. Approved for public release: distribution...official position of the US Government, Department of Defense, the United States Air Force , or Air University. iv ABOUT THE AUTHOR

  7. Ambient air quality in Slovak Republic

    SciTech Connect

    Violova, A.; Cremonini, M.G.; Lombardo, P.; Stenhouse, I.A.; Kocan, A.

    1998-07-01

    The National Government of the Slovak Republic is committed to develop an integrated strategy that will take into account global, regional and local aspects of the national emissions of pollutants. Priority is given to ambient air quality, with particular reference to human health protection. Only limited information on ambient air concentrations of hazardous air pollutants (HAP) was available in Slovakia. A comprehensive ambient air quality project has been recently funded by the European Union Phare Programme. The project was performed under the technical supervision of the Slovak Ministry of the Environment and aimed at monitoring the ambient air quality with respect to Volatile Organic Compounds (VOCs), persistent Organic Pollutants (POPs) and heavy metals (HMs), identifying and evaluating main potential pollution sources, and defining general strategies to reduce impacts.

  8. Call for improving air quality

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    2013-01-01

    The European Environmental Bureau (EEB), a federation of citizen organizations, has called for stricter policies in Europe to protect human health and the environment. "Air pollution emanates from sources all around us, be they cars, industrial plants, shipping, agriculture, or waste. The [European Union] must propose ambitious legislation to address all of these sources if it is to tackle the grave public health consequences of air pollution," EEB secretary general Jeremy Wates said on 8 January.

  9. Air Quality Planning Unit | Ground-level Ozone | New England ...

    EPA Pesticide Factsheets

    2017-04-10

    Looking for answers about a specific air quality issue? Here's a list of topics and programs related to air quality and Air Quality Planning (AQP) staff who can answer questions and provide information about them.

  10. Air Quality Planning Unit | Ground-level Ozone | New England ...

    EPA Pesticide Factsheets

    2017-09-05

    Looking for answers about a specific air quality issue? Here's a list of topics and programs related to air quality and Air Quality Planning (AQP) staff who can answer questions and provide information about them.

  11. Air quality and future energy system planning

    NASA Astrophysics Data System (ADS)

    Sobral Mourao, Zenaida; Konadu, Dennis; Lupton, Rick

    2016-04-01

    Ambient air pollution has been linked to an increasing number of premature deaths throughout the world. Projected increases in demand for food, energy resources and manufactured products will likely contribute to exacerbate air pollution with an increasing impact on human health, agricultural productivity and climate change. Current events such as tampering emissions tests by VW car manufacturers, failure to comply with EU Air Quality directives and WHO guidelines by many EU countries, the problem of smog in Chinese cities and new industrial emissions regulations represent unique challenges but also opportunities for regulators, local authorities and industry. However current models and practices of energy and resource use do not consider ambient air impacts as an integral part of the planing process. Furthermore the analysis of drivers, sources and impacts of air pollution is often fragmented, difficult to understand and lacks effective visualization tools that bring all of these components together. This work aims to develop a model that links impacts of air quality on human health and ecosystems to current and future developments in the energy system, industrial and agricultural activity and patterns of land use. The model will be added to the ForeseerTM tool, which is an integrated resource analysis platform that has been developed at the University of Cambridge initially with funding from BP and more recently through the EPSRC funded Whole Systems Energy Modeling (WholeSEM) project. The basis of the tool is a set of linked physical models for energy, water and land, including the technologies that are used to transform these resources into final services such as housing, food, transport and household goods. The new air quality model will explore different feedback effects between energy, land and atmospheric systems with the overarching goal of supporting better communication about the drivers of air quality and to incorporate concerns about air quality into

  12. Spatial Allocator for air quality modeling

    EPA Pesticide Factsheets

    The Spatial Allocator is a set of tools that helps users manipulate and generate data files related to emissions and air quality modeling without requiring the use of a commercial Geographic Information System.

  13. Coordinator's Guide for Indoor Air Quality

    EPA Pesticide Factsheets

    IAQ Tools for Schools Action Kit - IAQ Coordinator's Guide. This guidance is designed to present practical and often low-cost actions you can take to identify and address existing or potential air quality problems.

  14. Evaluating Regional-Scale Air Quality Models

    EPA Science Inventory

    Numerical air quality models are being used to understand the complex interplay among emission loading meteorology, and atmospheric chemistry leading to the formation and accumulation of pollutants in the atmosphere. A model evaluation framework is presented here that considers ...

  15. Monitoring Air Quality with Leaf Yeasts.

    ERIC Educational Resources Information Center

    Richardson, D. H. S.; And Others

    1985-01-01

    Proposes that leaf yeast serve as quick, inexpensive, and effective techniques for monitoring air quality. Outlines procedures and provides suggestions for data analysis. Includes results from sample school groups who employed this technique. (ML)

  16. Classroom Air Quality: Exploring the Indoor Environment.

    ERIC Educational Resources Information Center

    Borst, Richard

    1997-01-01

    Describes a teacher's experiences with Global Lab, which is depicted as a real-world networked science laboratory connecting individuals investigating global and local environmental change. Focuses on techniques to monitor indoor air quality. (DDR)

  17. Cooperative Agreement Funding for Indoor Air Quality

    EPA Pesticide Factsheets

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  18. Indoor Air Quality and Ice Arenas

    EPA Pesticide Factsheets

    All recreational facilities including ice arenas should use good ventilation practices especially where children are present. It is critical that indoor air quality is protected particularly when using fuel-burning equipment indoors.

  19. Publications about Indoor Air Quality in Schools

    EPA Pesticide Factsheets

    Publications and resources that relate to indoor air quality in schools, and design tools for schools. These publications cover a wide range of issues, including IAQ management, student performance, asthma, mold and moisture, and radon.

  20. Installing Portable Classrooms With Good Air Quality.

    ERIC Educational Resources Information Center

    Godfrey, Ray

    2000-01-01

    Discusses the advantages of modular classrooms and improvements made in indoor air quality, including the pros and cons of portables, challenges districts face when planning and installing portables, and cost considerations. Concluding comments highlight system costs and maintenance required. (GR)

  1. EVALUATING AND USING AIR QUALITY MODELS

    EPA Science Inventory

    Grid-based models are being used to assess the magnitude of the pollution problem and to design emission control strategies to achieve compliance with the relevant air quality standards in the United States.

  2. Indoor Air Quality and Energy Efficiency

    EPA Pesticide Factsheets

    EPA completed an extensive modeling study to assess the compatibilities and trade-offs between energy, indoor air quality, and thermal comfort objectives for HVAC systems and to formulate strategies for superior performance across all areas.

  3. Monitoring Air Quality with Leaf Yeasts.

    ERIC Educational Resources Information Center

    Richardson, D. H. S.; And Others

    1985-01-01

    Proposes that leaf yeast serve as quick, inexpensive, and effective techniques for monitoring air quality. Outlines procedures and provides suggestions for data analysis. Includes results from sample school groups who employed this technique. (ML)

  4. Guide for Indoor Air Quality Surveys

    DTIC Science & Technology

    1992-05-01

    Influencing Indoor Air Quality ................... 5 Carbon Dioxide and Fresh Air ........................ 6 Relative Humidity...037, A Procedural Guide on Sick Building Syndrome (Liebhaber, 1987), and supplements AFOEHL Report 90-169, Recommended Carbon Dioxide and Relative...symptoms. The causes most implicated in the literature include comfort parameters such as carbon dioxide (C02) concentration, relative humidity

  5. Air quality management in the United States

    SciTech Connect

    William Chameides; Daniel Greenbaum; Raymond Wassel; K. John Holmes; Karl Gustavson; Amanda Staudt

    2005-07-01

    In 2004, the National Research Council released Air Quality Management in the United States, a report prepared in response to a congressional request for an independent evaluation of the overall effectiveness of the Clean Air Act. Based on that report, this article summarizes the committee's findings and recommendations. 10 refs., 2 figs.

  6. Improving Regional Air Quality with Wind Energy

    SciTech Connect

    Not Available

    2005-05-01

    This model documentation is designed to assist State and local governments in pursuing wind energy purchases as a control measure under regional air quality plans. It is intended to support efforts to draft State Implementation Plans (SIPs), including wind energy purchases, to ensure compliance with the standard for ground-level ozone established under the Clean Air Act.

  7. MANAGING INDOOR AIR QUALITY IN THE USA

    EPA Science Inventory

    The paper gives an overview of managing indoor air quality (IAQ) in the U.S. In contrast to outdoor air, which is regulated through various federal and state statutes, there is no unified and comprehensive governmental regulation of IAQ. Therefore, IAQ is managed through variou...

  8. MANAGING INDOOR AIR QUALITY IN THE USA

    EPA Science Inventory

    The paper gives an overview of managing indoor air quality (IAQ) in the U.S. In contrast to outdoor air, which is regulated through various federal and state statutes, there is no unified and comprehensive governmental regulation of IAQ. Therefore, IAQ is managed through variou...

  9. Measuring indoor air quality of hookah lounges.

    PubMed

    Fiala, Steven C; Morris, Daniel S; Pawlak, Rebecca L

    2012-11-01

    Many states have implemented smoke-free workplace laws to protect employees and customers from exposure to secondhand smoke. However, exemptions in these laws have allowed indoor tobacco smoking in hookah lounges to proliferate in recent years. To describe the amount of secondhand smoke in hookah lounges, we measured the indoor air quality of 10 hookah lounges in Oregon. Air quality measurements ranged from "unhealthy" to "hazardous" according to Environmental Protection Agency standards, indicating a potential health risk for patrons and employees.

  10. Urban air quality estimation study, phase 1

    NASA Technical Reports Server (NTRS)

    Diamante, J. M.; Englar, T. S., Jr.; Jazwinski, A. H.

    1976-01-01

    Possibilities are explored for applying estimation theory to the analysis, interpretation, and use of air quality measurements in conjunction with simulation models to provide a cost effective method of obtaining reliable air quality estimates for wide urban areas. The physical phenomenology of real atmospheric plumes from elevated localized sources is discussed. A fluctuating plume dispersion model is derived. Individual plume parameter formulations are developed along with associated a priori information. Individual measurement models are developed.

  11. Exploring the critical quality attributes and models of smart homes.

    PubMed

    Ted Luor, Tainyi; Lu, Hsi-Peng; Yu, Hueiju; Lu, Yinshiu

    2015-12-01

    Research on smart homes has significantly increased in recent years owing to their considerably improved affordability and simplicity. However, the challenge is that people have different needs (or attitudes toward smart homes), and provision should be tailored to individuals. A few studies have classified the functions of smart homes. Therefore, the Kano model is first adopted as a theoretical base to explore whether the functional classifications of smart homes are attractive or necessary, or both. Second, three models and test user attitudes toward three function types of smart homes are proposed. Based on the Kano model, the principal results, namely, two "Attractive Quality" and nine "Indifferent Quality" items, are found. Verification of the hypotheses also indicates that the entertainment, security, and automation functions are significantly correlated with the variables "perceive useful" and "attitude." Cost consideration is negatively correlated with attitudes toward entertainment and automation. Results suggest that smart home providers should survey user needs for their product instead of merely producing smart homes based on the design of the builder or engineer.

  12. Quality of life for chronic psychiatric illnesses and home care

    PubMed Central

    Molu, Nesibe Gunay; Ozkan, Birgul; Icel, Sema

    2016-01-01

    Nowadays, mental illnesses are gradually increasing and so does chronic psychiatric patients. As a result of this increase, chronic psychiatric disorders lead the burden of patients and their families. To reduce the burden of mental illnesses on individuals and their families, treatment and care are given including psychosocial, physiological and medical support and social services. To begin with, home care enables both the patient and his or her family to stay at their own houses and not to be bothered with residents or long-term, institutional-based nursing homes. In addition, the home care providers deliver services to the patient’s at their own house. The other advantages of taking care at home is that it eases financial issues in terms of reducing the cost, reduces the patient’s symptoms and improve the individual’s quality of life (QoL). In addition to these, home care also minimizes the burden on outpatient services and provides help for the patient and the family in order to solve their problems and give support. Home care services help patients to get their freedom back and enhance the quality of their lives. Thus, it is necessary to procure and implement these services and supply both the patient and his or her family a high-quality life. Sources of data/ study selection: Literature review was done by using the keywords “home care, patient with chronic mental illness, quality of life, home care nursing” from the sources including PsychINFO, PsychARTICLES, MEDLINE, PubMED, EBSCOHOST and The COCHRANE LIBRARY in the time period of 2005- 2015. PMID:27182272

  13. 40 CFR 52.2676 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2676 Section 52.2676 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  14. 40 CFR 52.2779 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2779 Section 52.2779 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  15. 40 CFR 52.1180 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1180 Section 52.1180 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  16. 40 CFR 52.1234 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1234 Section 52.1234 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  17. 40 CFR 52.2676 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2676 Section 52.2676 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  18. 40 CFR 52.2729 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2729 Section 52.2729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  19. 40 CFR 52.2497 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2497 Section 52.2497 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  20. 40 CFR 52.2676 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2676 Section 52.2676 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  1. 40 CFR 52.2729 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2729 Section 52.2729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  2. 40 CFR 52.738 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.738 Section 52.738 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  3. 40 CFR 52.2779 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2779 Section 52.2779 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  4. 40 CFR 52.2497 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2497 Section 52.2497 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  5. 40 CFR 52.738 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.738 Section 52.738 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  6. 40 CFR 52.499 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.499 Section 52.499 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  7. 40 CFR 52.632 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.632 Section 52.632 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  8. 40 CFR 52.96 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.96 Section 52.96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The State of Alaska Department of Environmental Conservation Air Quality... deterioration of air quality. (b) The requirements of sections 160 through 165 of the Clean Air Act are not met...

  9. 40 CFR 52.1165 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1165 Section 52.1165 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulation for preventing significant deterioration of air quality. The...

  10. 40 CFR 52.2729 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2729 Section 52.2729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  11. 40 CFR 52.1165 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1165 Section 52.1165 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulation for preventing significant deterioration of air quality. The...

  12. 40 CFR 52.2729 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2729 Section 52.2729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  13. 40 CFR 52.2779 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2779 Section 52.2779 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  14. 40 CFR 52.1180 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1180 Section 52.1180 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  15. 40 CFR 52.499 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.499 Section 52.499 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  16. 40 CFR 52.1180 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1180 Section 52.1180 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  17. 40 CFR 52.1689 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1689 Section 52.1689 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  18. 40 CFR 52.1884 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1884 Section 52.1884 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  19. 40 CFR 52.499 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.499 Section 52.499 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  20. 40 CFR 52.2497 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2497 Section 52.2497 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  1. 40 CFR 52.2827 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2827 Section 52.2827 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  2. 40 CFR 52.1234 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1234 Section 52.1234 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  3. 40 CFR 52.1234 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1234 Section 52.1234 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  4. 40 CFR 52.1234 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1234 Section 52.1234 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  5. 40 CFR 52.1884 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1884 Section 52.1884 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  6. 40 CFR 52.1180 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1180 Section 52.1180 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  7. 40 CFR 52.1234 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1234 Section 52.1234 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  8. 40 CFR 52.632 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.632 Section 52.632 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  9. 40 CFR 52.1165 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1165 Section 52.1165 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulation for preventing significant deterioration of air quality. The...

  10. 40 CFR 52.2779 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2779 Section 52.2779 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  11. 40 CFR 52.2729 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2729 Section 52.2729 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  12. 40 CFR 52.1603 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1603 Section 52.1603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  13. 40 CFR 52.1884 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1884 Section 52.1884 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  14. 40 CFR 52.499 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.499 Section 52.499 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  15. 40 CFR 52.2827 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2827 Section 52.2827 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  16. 40 CFR 52.1165 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1165 Section 52.1165 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulation for preventing significant deterioration of air quality. The...

  17. 40 CFR 52.738 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.738 Section 52.738 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  18. 40 CFR 52.1603 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1603 Section 52.1603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  19. 40 CFR 52.1180 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1180 Section 52.1180 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  20. 40 CFR 52.793 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.793 Section 52.793 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  1. 40 CFR 52.432 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.432 Section 52.432 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulation for preventing significant deterioration of air quality. The provisions of...

  2. 40 CFR 52.1603 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1603 Section 52.1603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  3. 40 CFR 52.1603 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1603 Section 52.1603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  4. 40 CFR 52.1884 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1884 Section 52.1884 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  5. 40 CFR 52.1165 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1165 Section 52.1165 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulation for preventing significant deterioration of air quality. The...

  6. 40 CFR 52.1603 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1603 Section 52.1603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  7. 40 CFR 52.2779 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2779 Section 52.2779 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  8. 40 CFR 52.738 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.738 Section 52.738 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  9. 40 CFR 52.499 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.499 Section 52.499 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  10. 40 CFR 52.2676 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2676 Section 52.2676 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  11. 40 CFR 52.632 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.632 Section 52.632 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  12. 40 CFR 52.738 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.738 Section 52.738 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  13. 40 CFR 52.632 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.632 Section 52.632 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  14. 40 CFR 52.2827 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2827 Section 52.2827 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  15. 40 CFR 52.632 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.632 Section 52.632 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  16. 40 CFR 52.793 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.793 Section 52.793 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  17. 40 CFR 52.432 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.432 Section 52.432 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulation for preventing significant deterioration of air quality. The provisions of...

  18. 40 CFR 52.793 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.793 Section 52.793 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  19. 40 CFR 52.2827 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2827 Section 52.2827 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  20. 40 CFR 52.1884 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1884 Section 52.1884 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  1. 40 CFR 52.793 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.793 Section 52.793 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The provisions...

  2. 40 CFR 52.432 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.432 Section 52.432 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulation for preventing significant deterioration of air quality. The provisions of...

  3. 40 CFR 52.2497 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2497 Section 52.2497 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  4. 40 CFR 52.2497 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2497 Section 52.2497 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  5. 40 CFR 52.2827 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2827 Section 52.2827 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  6. 40 CFR 52.2676 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2676 Section 52.2676 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  7. 40 CFR 52.793 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.793 Section 52.793 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are not met... air quality. (b) Regulations for preventing significant deterioration of air quality. The...

  8. The ReACH Collaborative--improving quality home care.

    PubMed

    Boyce, Patricia Simino; Pace, Karen B; Lauder, Bonnie; Solomon, Debra A

    2007-08-01

    Research on quality of care has shown that vigorous leadership, clear goals, and compatible incentive systems are critical factors in influencing successful change (Institute of Medicine, 2001). Quality improvement is a complex process, and clinical quality improvement applications are more likely to be effective in organizations that are ready for change and have strong leaders, who are committed to creating and reinforcing a work environment that supports quality goals (Shortell, 1998). Key leadership roles include providing clear and sustained direction, articulating a coherent set of values and incentives to guide group and individual activities, aligning and integrating improvement efforts into organizational priorities, obtaining or freeing up resources to implement improvement activities, and creating a culture of "continuous improvement" that encourages and rewards the pursuit and achievement of shared quality aims (Institute of Medicine, 2001, 70-71). In summary, home health care is a significant and growing sector of the health care system that provides care to millions of vulnerable patients. There seems little doubt that home health agencies want to focus on quality of care issues and provide optimal care to home-based patients. Furthermore, there is a growing awareness of the value for adapting innovative, effective models for improving the culture of home care practice. This awareness stems from the notion that some agencies see quality improvement activities as a way for them to distinguish themselves not only to regulators and customers, but also to meet the cultural and transformational needs to remain viable in a constantly evolving and competitive health care industry.

  9. Does state regulation of quality impose costs on nursing homes?

    PubMed

    Mukamel, Dana B; Li, Yue; Harrington, Charlene; Spector, William D; Weimer, David L; Bailey, Lauren

    2011-06-01

    Government regulation is intended to enhance quality, safety, fairness, or competition in the regulated industry. Such regulation entails both direct and indirect costs. To estimate the costs associated with the regulation of quality of the nursing home industry. This study includes 11,168 free-standing nursing homes nationally, between 2004 and 2006. Data included information from the Medicare cost reports, Minimum Data Set, Medicare Denominator file, OSCAR, and a survey of States' Certification and Licensing Offices conducted by the authors. These data were used to create variables measuring nursing homes costs, outputs, wages, competition, adjusted deficiency citations, ownership, state-fixed effects, and an index of each state's regulatory stringency. We estimated hybrid cost functions which included the regulatory stringency index. The estimated cost functions demonstrated the typical behavior expected of nursing home cost functions. The stringency index was positively and significantly associated with costs, indicating that nursing homes located in states with more stringent regulatory requirements face higher costs, ceteris paribus. The average incremental costs of a 1 standard deviation increase in the stringency index resulted in a 1.1% increase in costs. This study for the first time places a price tag on the regulation of quality in nursing homes. It offers an order of magnitude on the costs to the industry of complying with the current set of standards and given the current level of enforcement. Complementary studies of the benefits that these regulations entail are needed to gain a comprehensive assessment of the effect of the regulation.

  10. Relationship of Nursing Home Staffing to Quality of Care

    PubMed Central

    Schnelle, John F; Simmons, Sandra F; Harrington, Charlene; Cadogan, Mary; Garcia, Emily; Bates-Jensen, Barbara M

    2004-01-01

    Objective To compare nursing homes (NHs) that report different staffing statistics on quality of care. Data Sources Staffing information generated by California NHs on state cost reports and during onsite interviews. Data independently collected by research staff describing quality of care related to 27 care processes. Study Design Two groups of NHs (n=21) that reported significantly different and stable staffing data from all data sources were compared on quality of care measures. Data Collection Direct observation, resident and staff interview, and chart abstraction methods. Principal Findings Staff in the highest staffed homes (n=6), according to state cost reports, reported significantly lower resident care loads during onsite interviews across day and evening shifts (7.6 residents per nurse aide [NA]) compared to the remaining homes that reported between 9 to 10 residents per NA (n=15). The highest-staffed homes performed significantly better on 13 of 16 care processes implemented by NAs compared to lower-staffed homes. Conclusion The highest-staffed NHs reported significantly lower resident care loads on all staffing reports and provided better care than all other homes. PMID:15032952

  11. Atmospheric Model Evaluation Tool for meteorological and air quality simulations

    EPA Pesticide Factsheets

    The Atmospheric Model Evaluation Tool compares model predictions to observed data from various meteorological and air quality observation networks to help evaluate meteorological and air quality simulations.

  12. Air Quality Procedures for Civilian Airports and Air Force Bases

    DTIC Science & Technology

    1982-12-01

    standards. These are primary standards which are designed to pro.: tect human health and secondary standards which are established to protect human...petrochemical operations and solvent usage, with some contribution from waste burning. Hydrocarbons are not, by themselves, a health hazard; rather, it is...various project sources; local air, cuality regulations; and any ambient air quality data that has beet recorded in or near the pro3ect site. Once the

  13. Air Quality Instrumentation. Volume 1.

    ERIC Educational Resources Information Center

    Scales, John W., Ed.

    To insure a wide dissemination of information describing advances in measurement and control techniques, the Instrument Society of America (ISA) has published this monograph of selected papers from recent ISA symposia dealing with air pollution. Papers range from a discussion of some relatively new applications of proven techniques to discussions…

  14. Air Quality Instrumentation. Volume 1.

    ERIC Educational Resources Information Center

    Scales, John W., Ed.

    To insure a wide dissemination of information describing advances in measurement and control techniques, the Instrument Society of America (ISA) has published this monograph of selected papers from recent ISA symposia dealing with air pollution. Papers range from a discussion of some relatively new applications of proven techniques to discussions…

  15. Air Quality Instrumentation. Volume 2.

    ERIC Educational Resources Information Center

    Scales, John W., Ed.

    To insure a wide dissemination of information describing advances in measurement and control techniques, the Instrument Society of America (ISA) has published this monograph of selected papers, the second in a series, from recent ISA symposia dealing with air pollution. Papers range from a discussion of individual pollutant measurements to…

  16. Air Quality Instrumentation. Volume 2.

    ERIC Educational Resources Information Center

    Scales, John W., Ed.

    To insure a wide dissemination of information describing advances in measurement and control techniques, the Instrument Society of America (ISA) has published this monograph of selected papers, the second in a series, from recent ISA symposia dealing with air pollution. Papers range from a discussion of individual pollutant measurements to…

  17. The effect of state regulatory stringency on nursing home quality.

    PubMed

    Mukamel, Dana B; Weimer, David L; Harrington, Charlene; Spector, William D; Ladd, Heather; Li, Yue

    2012-10-01

    To test the hypothesis that more stringent quality regulations contribute to better quality nursing home care and to assess their cost-effectiveness. Primary and secondary data from all states and U.S. nursing homes between 2005 and 2006. We estimated seven models, regressing quality measures on the Harrington Regulation Stringency Index and control variables. To account for endogeneity between regulation and quality, we used instrumental variables techniques. Quality was measured by staffing hours by type per case-mix adjusted day, hotel expenditures, and risk-adjusted decline in activities of daily living, high-risk pressure sores, and urinary incontinence. All states' licensing and certification offices were surveyed to obtain data about deficiencies. Secondary data included the Minimum Data Set, Medicare Cost Reports, and the Economic Freedom Index. Regulatory stringency was significantly associated with better quality for four of the seven measures studied. The cost-effectiveness for the activities-of-daily-living measure was estimated at about 72,000 in 2011/ Quality Adjusted Life Year. Quality regulations lead to better quality in nursing homes along some dimensions, but not all. Our estimates of cost-effectiveness suggest that increased regulatory stringency is in the ballpark of other acceptable cost-effective practices. © Health Research and Educational Trust.

  18. The Effect of State Regulatory Stringency on Nursing Home Quality

    PubMed Central

    Mukamel, Dana B; Weimer, David L; Harrington, Charlene; Spector, William D; Ladd, Heather; Li, Yue

    2012-01-01

    Objective To test the hypothesis that more stringent quality regulations contribute to better quality nursing home care and to assess their cost-effectiveness. Data Sources/Setting Primary and secondary data from all states and U.S. nursing homes between 2005 and 2006. Study Design We estimated seven models, regressing quality measures on the Harrington Regulation Stringency Index and control variables. To account for endogeneity between regulation and quality, we used instrumental variables techniques. Quality was measured by staffing hours by type per case-mix adjusted day, hotel expenditures, and risk-adjusted decline in activities of daily living, high-risk pressure sores, and urinary incontinence. Data Collection All states' licensing and certification offices were surveyed to obtain data about deficiencies. Secondary data included the Minimum Data Set, Medicare Cost Reports, and the Economic Freedom Index. Principal Findings Regulatory stringency was significantly associated with better quality for four of the seven measures studied. The cost-effectiveness for the activities-of-daily-living measure was estimated at about 72,000 in 2011/ Quality Adjusted Life Year. Conclusions Quality regulations lead to better quality in nursing homes along some dimensions, but not all. Our estimates of cost-effectiveness suggest that increased regulatory stringency is in the ballpark of other acceptable cost-effective practices. PMID:22946859

  19. COMPETITION AND QUALITY IN HOME HEALTH CARE MARKETS†

    PubMed Central

    JUNG, KYOUNGRAE; POLSKY, DANIEL

    2013-01-01

    SUMMARY Market-based solutions are often proposed to improve health care quality; yet evidence on the role of competition in quality in non-hospital settings is sparse. We examine the relationship between competition and quality in home health care. This market is different from other markets in that service delivery takes place in patients’ homes, which implies low costs of market entry and exit for agencies. We use 6 years of panel data for Medicare beneficiaries during the early 2000s. We identify the competition effect from within-market variation in competition over time. We analyze three quality measures: functional improvements, the number of home health visits, and discharges without hospitalization. We find that the relationship between competition and home health quality is nonlinear and its pattern differs by quality measure. Competition has positive effects on functional improvements and the number of visits in most ranges, but in the most competitive markets, functional outcomes and the number of visits slightly drop. Competition has a negative effect on discharges without hospitalization that is strongest in the most competitive markets. This finding is different from prior research on hospital markets and suggests that market-specific environments should be considered in developing polices to promote competition. PMID:23670849

  20. Competition and quality in home health care markets.

    PubMed

    Jung, Kyoungrae; Polsky, Daniel

    2014-03-01

    Market-based solutions are often proposed to improve health care quality; yet evidence on the role of competition in quality in non-hospital settings is sparse. We examine the relationship between competition and quality in home health care. This market is different from other markets in that service delivery takes place in patients' homes, which implies low costs of market entry and exit for agencies. We use 6 years of panel data for Medicare beneficiaries during the early 2000s. We identify the competition effect from within-market variation in competition over time. We analyze three quality measures: functional improvements, the number of home health visits, and discharges without hospitalization. We find that the relationship between competition and home health quality is nonlinear and its pattern differs by quality measure. Competition has positive effects on functional improvements and the number of visits in most ranges, but in the most competitive markets, functional outcomes and the number of visits slightly drop. Competition has a negative effect on discharges without hospitalization that is strongest in the most competitive markets. This finding is different from prior research on hospital markets and suggests that market-specific environments should be considered in developing polices to promote competition.

  1. Evaluating the effectiveness of air quality interventions.

    PubMed

    van Erp, Annemoon M M; O'Keefe, Robert; Cohen, Aaron J; Warren, Jane

    2008-01-01

    Evaluating the extent to which air quality regulations improve public health--sometimes referred to as accountability--is part of an emerging effort to assess the effectiveness of environmental regulatory policies. Air quality has improved substantially in the United States and Western Europe in recent decades, with far less visible pollution and decreasing concentrations of several major pollutants. In large part, these gains were achieved through increasingly stringent air quality regulations. The costs associated with compliance and, importantly, the need to ensure that the regulations are achieving the intended public health benefits underscore the importance of accountability research. To date, accountability research has emphasized measuring the effects of actions already taken to improve air quality. Such research may also contribute to estimating the burden of disease that might be avoided in the future if certain actions are taken. The Health Effects Institute (HEI) currently funds eight ongoing studies on accountability, which cover near-term interventions to improve air quality including (1) a ban on the sale of coal, (2) replacing old wood stoves with cleaner ones, (3) decreasing sulfur content in fuel, (4) measures to reduce traffic, and (5) longer term, wide-ranging actions or events (such as complex changes associated with the reunification of Germany). HEI is also funding the development of methods and research to assess regulations that are implemented incrementally over extended periods of time, such as Title IV of the 1990 Clean Air Act Amendments, which reduces sulfur dioxide emissions from power plants in the eastern United States.

  2. Quality assessment of palliative home care in Italy.

    PubMed

    Scaccabarozzi, Gianlorenzo; Lovaglio, Pietro Giorgio; Limonta, Fabrizio; Floriani, Maddalena; Pellegrini, Giacomo

    2017-08-01

    The complexity of end-of-life care, represented by a large number of units caring for dying patients, of different types of organizations motivates the importance of measure the quality of provided care. Despite the law 38/2010 promulgated to remove the barriers and provide affordable access to palliative care, measurement, and monitoring of processes of home care providers in Italy has not been attempted. Using data drawn by an institutional voluntary observatory established in Italy in 2013, collecting home palliative care units caring for people between January and December 2013, we assess the degree to which Italian home palliative care teams endorse a set of standards required by the 38/2010 law and best practices as emerged from the literature. The evaluation strategy is based on Rasch analysis, allowing to objectively measuring both performances of facilities and quality indicators' difficulty on the same metric, using 14 quality indicators identified by the observatory's steering committee. Globally, 195 home care teams were registered in the observatory reporting globally 40 955 cured patients in 2013 representing 66% of the population of home palliative care units active in Italy in 2013. Rasch analysis identifies 5 indicators ("interview" with caregivers, continuous training provided to medical and nursing staff, provision of specialized multidisciplinary interventions, psychological support to the patient and family, and drug supply at home) easy to endorse by health care providers and 3 problematic indicators (presence of a formally established Local Network of Palliative care in the area of reference, provision of the care for most problematic patient requiring high intensity of the care, and the percentage of cancer patient dying at Home). The lack of Local Network of Palliative care, required by law 38/2010, is, at the present, the main barrier to its application. However, the adopted methodology suggests that a clear roadmap for health facilities

  3. Survey-based Indices for Nursing Home Quality Incentive Reimbursement

    PubMed Central

    Willemain, Thomas R.

    1983-01-01

    Incentive payments are a theoretically appealing complement to nursing home quality assurance systems that rely on regulatory enforcement. However, the practical aspects of incentive program design are not yet well understood. After reviewing the rationale for incentive approaches and recent State and. Federal initiatives, the article considers a basic program design issue: creating an index of nursing home quality. It focuses on indices constructed from routine licensure and certification survey results because State initiatives have relied heavily on these readily accessible data. It also suggests a procedure for creating a survey-based index and discusses a sampling of Implementation issues. PMID:10309858

  4. Indoor Air Quality and Asthma

    PubMed Central

    Holm, Stewart

    2017-01-01

    Numerous contaminants in indoor air and their potential to cause or exacerbate asthma continue to be a subject of public health concern. Many agents are causally associated with or can exacerbate asthma, particularly in children. For formaldehyde, an established respiratory irritant based on numerous studies, the evidence for an association with asthma is still considered only limited or suggestive. However, there is no evidence that indicates increased sensitivity to sensory irritation to formaldehyde in people often regarded as susceptible such as asthmatics. Acrolein, but not formaldehyde, was significantly associated with asthma in a large cohort of children. This prompted an evaluation of this highly irritating chemical that had never previously been considered in the context of the indoor air/childhood asthma issue. Because acrolein is more potent than formaldehyde as a respiratory irritant and ubiquitous in indoor air, it is plausible that previous studies on potential risk factors and childhood asthma may be confounded by formaldehyde acting as an unrecognized proxy for acrolein. PMID:28250718

  5. Leadership, staffing and quality of care in nursing homes.

    PubMed

    Havig, Anders Kvale; Skogstad, Anders; Kjekshus, Lars Erik; Romøren, Tor Inge

    2011-11-28

    Leadership and staffing are recognised as important factors for quality of care. This study examines the effects of ward leaders' task- and relationship-oriented leadership styles, staffing levels, ratio of registered nurses and ratio of unlicensed staff on three independent measures of quality of care. A cross-sectional survey of forty nursing home wards throughout Norway was used to collect the data. Five sources of data were utilised: self-report questionnaires to 444 employees, interviews with and questionnaires to 13 nursing home directors and 40 ward managers, telephone interviews with 378 relatives and 900 hours of field observations. Separate multi-level analyses were conducted for quality of care assessed by relatives, staff and field observations respectively. Task-oriented leadership style had a significant positive relationship with two of the three quality of care indexes. In contrast, relationship-oriented leadership style was not significantly related to any of the indexes. The lack of significant effect for relationship-oriented leadership style was due to a strong correlation between the two leadership styles (r=0.78). Staffing levels and ratio of registered nurses were not significantly related to any of the quality of care indexes. The ratio of unlicensed staff, however, showed a significant negative relationship to quality as assessed by relatives and field observations, but not to quality as assessed by staff. Leaders in nursing homes should focus on active leadership and particularly task-oriented behaviour like structure, coordination, clarifying of staff roles and monitoring of operations to increase quality of care. Furthermore, nursing homes should minimize use of unlicensed staff and address factors related to high ratios of unlicensed staff, like low staff stability. The study indicates, however, that the relationship between staffing levels, ratio of registered nurses and quality of care is complex. Increasing staffing levels or the

  6. Leadership, staffing and quality of care in nursing homes

    PubMed Central

    2011-01-01

    Background Leadership and staffing are recognised as important factors for quality of care. This study examines the effects of ward leaders' task- and relationship-oriented leadership styles, staffing levels, ratio of registered nurses and ratio of unlicensed staff on three independent measures of quality of care. Methods A cross-sectional survey of forty nursing home wards throughout Norway was used to collect the data. Five sources of data were utilised: self-report questionnaires to 444 employees, interviews with and questionnaires to 13 nursing home directors and 40 ward managers, telephone interviews with 378 relatives and 900 hours of field observations. Separate multi-level analyses were conducted for quality of care assessed by relatives, staff and field observations respectively. Results Task-oriented leadership style had a significant positive relationship with two of the three quality of care indexes. In contrast, relationship-oriented leadership style was not significantly related to any of the indexes. The lack of significant effect for relationship-oriented leadership style was due to a strong correlation between the two leadership styles (r = 0.78). Staffing levels and ratio of registered nurses were not significantly related to any of the quality of care indexes. The ratio of unlicensed staff, however, showed a significant negative relationship to quality as assessed by relatives and field observations, but not to quality as assessed by staff. Conclusions Leaders in nursing homes should focus on active leadership and particularly task-oriented behaviour like structure, coordination, clarifying of staff roles and monitoring of operations to increase quality of care. Furthermore, nursing homes should minimize use of unlicensed staff and address factors related to high ratios of unlicensed staff, like low staff stability. The study indicates, however, that the relationship between staffing levels, ratio of registered nurses and quality of care is

  7. Malpractice Litigation and Nursing Home Quality of Care

    PubMed Central

    Konetzka, R Tamara; Park, Jeongyoung; Ellis, Robert; Abbo, Elmer

    2013-01-01

    Objective. To assess the potential deterrent effect of nursing home litigation threat on nursing home quality. Data Sources/Study Setting. We use a panel dataset of litigation claims and Nursing Home Online Survey Certification and Reporting (OSCAR) data from 1995 to 2005 in six states: Florida, Illinois, Wisconsin, New Jersey, Missouri, and Delaware, for a total of 2,245 facilities. Claims data are from Westlaw's Adverse Filings database, a proprietary legal database, on all malpractice, negligence, and personal injury/wrongful death claims filed against nursing facilities. Study Design. A lagged 2-year moving average of the county-level number of malpractice claims is used to represent the threat of litigation. We use facility fixed-effects models to examine the relationship between the threat of litigation and nursing home quality. Principal Findings. We find significant increases in registered nurse-to-total staffing ratios in response to rising malpractice threat, and a reduction in pressure sores among highly staffed facilities. However, the magnitude of the deterrence effect is small. Conclusions. Deterrence in response to the threat of malpractice litigation is unlikely to lead to widespread improvements in nursing home quality. This should be weighed against other benefits and costs of litigation to assess the net benefit of tort reform. PMID:23741985

  8. Climate change, air quality, and human health.

    PubMed

    Kinney, Patrick L

    2008-11-01

    Weather and climate play important roles in determining patterns of air quality over multiple scales in time and space, owing to the fact that emissions, transport, dilution, chemical transformation, and eventual deposition of air pollutants all can be influenced by meteorologic variables such as temperature, humidity, wind speed and direction, and mixing height. There is growing recognition that development of optimal control strategies for key pollutants like ozone and fine particles now requires assessment of potential future climate conditions and their influence on the attainment of air quality objectives. In addition, other air contaminants of relevance to human health, including smoke from wildfires and airborne pollens and molds, may be influenced by climate change. In this study, the focus is on the ways in which health-relevant measures of air quality, including ozone, particulate matter, and aeroallergens, may be affected by climate variability and change. The small but growing literature focusing on climate impacts on air quality, how these influences may play out in future decades, and the implications for human health is reviewed. Based on the observed and anticipated impacts, adaptation strategies and research needs are discussed.

  9. Predicting indoor pollutant concentrations, and applications to air quality management

    SciTech Connect

    Lorenzetti, David M.

    2002-10-01

    Because most people spend more than 90% of their time indoors, predicting exposure to airborne pollutants requires models that incorporate the effect of buildings. Buildings affect the exposure of their occupants in a number of ways, both by design (for example, filters in ventilation systems remove particles) and incidentally (for example, sorption on walls can reduce peak concentrations, but prolong exposure to semivolatile organic compounds). Furthermore, building materials and occupant activities can generate pollutants. Indoor air quality depends not only on outdoor air quality, but also on the design, maintenance, and use of the building. For example, ''sick building'' symptoms such as respiratory problems and headaches have been related to the presence of air-conditioning systems, to carpeting, to low ventilation rates, and to high occupant density (1). The physical processes of interest apply even in simple structures such as homes. Indoor air quality models simulate the processes, such as ventilation and filtration, that control pollutant concentrations in a building. Section 2 describes the modeling approach, and the important transport processes in buildings. Because advection usually dominates among the transport processes, Sections 3 and 4 describe methods for predicting airflows. The concluding section summarizes the application of these models.

  10. 40 CFR 52.683 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.683 Section 52.683 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The State of Idaho Rules for Control of Air Pollution in Idaho, specifically... the Clean Air Act for preventing significant deterioration of air quality. (b) The requirements of...

  11. 40 CFR 52.683 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.683 Section 52.683 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The State of Idaho Rules for Control of Air Pollution in Idaho, specifically... the Clean Air Act for preventing significant deterioration of air quality. (b) The requirements of...

  12. 40 CFR 52.683 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.683 Section 52.683 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The State of Idaho Rules for Control of Air Pollution in Idaho, specifically... the Clean Air Act for preventing significant deterioration of air quality. (b) The requirements of...

  13. 40 CFR 52.683 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.683 Section 52.683 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The State of Idaho Rules for Control of Air Pollution in Idaho, specifically... Air Act for preventing significant deterioration of air quality. (b) The requirements of sections 160...

  14. 30 CFR 250.302 - Definitions concerning air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Definitions concerning air quality. 250.302... Definitions concerning air quality. For purposes of §§ 250.303 and 250.304 of this part: Air pollutant means..., pursuant to section 109 of the Clean Air Act, national primary or secondary ambient air quality...

  15. Staffing Subsidies and the Quality of Care in Nursing Homes

    PubMed Central

    Foster, Andrew D.; Lee, Yong Suk

    2015-01-01

    Concerns about the quality of state-financed nursing home care has led to the wide-scale adoption by states of pass-through subsidies, in which Medicaid reimbursement rates are directly tied to staffing expenditure. We examine the effects of Medicaid pass-through on nursing home staffing and quality of care by adapting a two-step FGLS method that addresses clustering and state-level temporal autocorrelation. We find that pass-through subsidies increases staffing by about 1% on average and 2.7% in nursing homes with a low share of Medicaid patients. Furthermore, pass-through subsidies reduce the incidences of pressure ulcer worsening by about 0.9%. PMID:25814437

  16. The biofiltration of indoor air: implications for air quality.

    PubMed

    Darlington, A; Chan, M; Malloch, D; Pilger, C; Dixon, M A

    2000-03-01

    An alternative method of maintaining indoor air quality may be through the biofiltration of air recirculating within the structure rather than the traditional approach of ventilation. This approach is currently being investigated. Prior to its acceptance for dealing with volatile organic compounds (VOCs) and CO2, efforts were made to determine whether the incorporation of this amount of biomass into the indoor space can have an (negative) impact on indoor air quality. A relatively large ecologically complex biofilter composed of a ca. 10 m2 bioscrubber, 30 m2 of plantings and a 3,500 litre aquarium were established in a 160 m2 'airtight' room in a recently constructed office building in downtown Toronto. This space maintained ca. 0.2 air changes per hour (ACH) compared to the 15 to 20 ACH (with a 30% refresh rate) of other spaces in the same building. Air quality parameters of concern were total VOCs (TVOCs), formaldehyde and aerial spore counts. TVOC and formaldehyde levels in the biofilter room were the same or significantly less than other spaces in the building despite a much slower refresh rate. Aerial spore levels were slightly higher than other indoor spaces but were well within reported values for 'healthy' indoor spaces. Levels appeared to be dependent on horticultural management practices within the space. Most genera of fungal spores present were common indoors and the other genera were associated with living or dead plant material or soil. From these results, the incorporation of a large amount of biomass associated with indoor biofilters does not in itself lower indoor air quality.

  17. Air quality modeling in support of the Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS).

    PubMed

    Isakov, Vlad; Arunachalam, Saravanan; Batterman, Stuart; Bereznicki, Sarah; Burke, Janet; Dionisio, Kathie; Garcia, Val; Heist, David; Perry, Steve; Snyder, Michelle; Vette, Alan

    2014-08-27

    A major challenge in traffic-related air pollution exposure studies is the lack of information regarding pollutant exposure characterization. Air quality modeling can provide spatially and temporally varying exposure estimates for examining relationships between traffic-related air pollutants and adverse health outcomes. A hybrid air quality modeling approach was used to estimate exposure to traffic-related air pollutants in support of the Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS) conducted in Detroit (Michigan, USA). Model-based exposure metrics, associated with local variations of emissions and meteorology, were estimated using a combination of the American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) and Research LINE-source dispersion model for near-surface releases (RLINE) dispersion models, local emission source information from the National Emissions Inventory, detailed road network locations and traffic activity, and meteorological data from the Detroit City Airport. The regional background contribution was estimated using a combination of the Community Multi-scale Air Quality (CMAQ) and the Space-Time Ordinary Kriging (STOK) models. To capture the near-road pollutant gradients, refined "mini-grids" of model receptors were placed around participant homes. Exposure metrics for CO, NOx, PM2.5 and its components (elemental and organic carbon) were predicted at each home location for multiple time periods including daily and rush hours. The exposure metrics were evaluated for their ability to characterize the spatial and temporal variations of multiple ambient air pollutants compared to measurements across the study area.

  18. 76 FR 76048 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-06

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 81 RIN 2060-AR17 Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards Correction In rule document 2011-29460 appearing on pages 72097-72120 in the issues of...

  19. Contribution of solid fuel, gas combustion, or tobacco smoke to indoor air pollutant concentrations in Irish and Scottish homes.

    PubMed

    Semple, S; Garden, C; Coggins, M; Galea, K S; Whelan, P; Cowie, H; Sánchez-Jiménez, A; Thorne, P S; Hurley, J F; Ayres, J G

    2012-06-01

      There are limited data describing pollutant levels inside homes that burn solid fuel within developed country settings with most studies describing test conditions or the effect of interventions. This study recruited homes in Ireland and Scotland where open combustion processes take place. Open combustion was classified as coal, peat, or wood fuel burning, use of a gas cooker or stove, or where there is at least one resident smoker. Twenty-four-hour data on airborne concentrations of particulate matter<2.5 μm in size (PM2.5), carbon monoxide (CO), endotoxin in inhalable dust and carbon dioxide (CO2), together with 2-3 week averaged concentrations of nitrogen dioxide (NO2) were collected in 100 houses during the winter and spring of 2009-2010. The geometric mean of the 24-h time-weighted-average (TWA) PM2.5 concentration was highest in homes with resident smokers (99 μg/m3--much higher than the WHO 24-h guidance value of 25 μg/m3). Lower geometric mean 24-h TWA levels were found in homes that burned coal (7 μg/m3) or wood (6 μg/m3) and in homes with gas cookers (7 μg/m3). In peat-burning homes, the average 24-h PM2.5 level recorded was 11 μg/m3. Airborne endotoxin, CO, CO2, and NO2 concentrations were generally within indoor air quality guidance levels. Little is known about indoor air quality (IAQ) in homes that burn solid or fossil-derived fuels in economically developed countries. Recent legislative changes have moved to improve IAQ at work and in enclosed public places, but there remains a real need to begin the process of quantifying the health burden that arises from indoor air pollution within domestic environments. This study demonstrates that homes in Scotland and Ireland that burn solid fuels or gas for heating and cooking have concentrations of air pollutants generally within guideline levels. Homes where combustion of cigarettes takes place have much poorer air quality. © 2011 John Wiley & Sons A/S.

  20. Home Safety and Low-Income Urban Housing Quality

    PubMed Central

    Shields, Wendy; McDonald, Eileen; Frattaroli, Shannon; Bishai, David; Ma, Xia

    2012-01-01

    OBJECTIVES: Living in substandard housing may be one factor that increases the risk of fire and burn injuries in low-income urban environments. The purposes of this study are to (1) describe the frequency and characteristics of substandard housing in urban homes with young children and (2) explore the hypothesis that better housing quality is associated with a greater likelihood of having working smoke alarms and safe hot water temperatures. METHODS: A total 246 caregivers of children ages 0 to 7 years were recruited from a pediatric emergency department and a well-child clinic. In-home observations were completed by using 46 items from the Housing and Urban Development’s Housing Quality Standards. RESULTS: Virtually all homes (99%) failed the housing quality measure. Items with the highest failure rates were those related to heating and cooling; walls, ceilings, and floors; and sanitation and safety domains. One working smoke alarm was observed in 82% of the homes, 42% had 1 on every level, and 62% had safe hot water temperatures. For every increase of 1 item in the number of housing quality items passed, the odds of having any working smoke alarm increased by 10%, the odds of having 1 on every level by 18%, and the odds of having safe hot water temperatures by 8%. CONCLUSIONS: Many children may be at heightened risk for fire and scald burns by virtue of their home environment. Stronger collaboration between housing, health care, and injury prevention professionals is urgently needed to maximize opportunities to improve home safety. PMID:23147973

  1. Indoor air quality in Brazilian universities.

    PubMed

    Jurado, Sonia R; Bankoff, Antônia D P; Sanchez, Andrea

    2014-07-11

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (<80 µg/m3) in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively). The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  2. 40 CFR 52.931 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.931 Section 52.931 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) Regulations for preventing significant deterioration of air quality. The..., the Kentucky Division for Air Quality has determined that the application complies with the applicable...

  3. 40 CFR 52.931 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.931 Section 52.931 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) Regulations for preventing significant deterioration of air quality. The..., the Kentucky Division for Air Quality has determined that the application complies with the applicable...

  4. 40 CFR 51.320 - Annual air quality data report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Annual air quality data report. 51.320... REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Reports Air Quality Data Reporting § 51.320 Annual air quality data report. The requirements for reporting air quality data collected...

  5. 40 CFR 52.931 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.931 Section 52.931 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) Regulations for preventing significant deterioration of air quality. The..., the Kentucky Division for Air Quality has determined that the application complies with the applicable...

  6. 40 CFR 51.320 - Annual air quality data report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Annual air quality data report. 51.320... REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Reports Air Quality Data Reporting § 51.320 Annual air quality data report. The requirements for reporting air quality data collected...

  7. 40 CFR 52.931 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.931 Section 52.931 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) Regulations for preventing significant deterioration of air quality. The..., the Kentucky Division for Air Quality has determined that the application complies with the applicable...

  8. 40 CFR 52.2451 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2451 Section 52.2451 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for preventing significant deterioration of air quality. The...

  9. 40 CFR 51.320 - Annual air quality data report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Annual air quality data report. 51.320... REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Reports Air Quality Data Reporting § 51.320 Annual air quality data report. The requirements for reporting air quality data collected...

  10. 40 CFR 52.2528 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2528 Section 52.2528 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of Sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for Preventing Significant Deterioration of Air Quality, the...

  11. 40 CFR 52.2528 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2528 Section 52.2528 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of Sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for Preventing Significant Deterioration of Air Quality, the...

  12. 40 CFR 52.2451 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.2451 Section 52.2451 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for preventing significant deterioration of air quality. The...

  13. 40 CFR 51.320 - Annual air quality data report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Annual air quality data report. 51.320... REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Reports Air Quality Data Reporting § 51.320 Annual air quality data report. The requirements for reporting air quality data collected...

  14. 40 CFR 52.2451 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2451 Section 52.2451 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for preventing significant deterioration of air quality. The...

  15. 40 CFR 52.2451 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2451 Section 52.2451 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for preventing significant deterioration of air quality. The...

  16. 40 CFR 52.2451 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2451 Section 52.2451 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for preventing significant deterioration of air quality. The...

  17. 40 CFR 51.320 - Annual air quality data report.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Annual air quality data report. 51.320... REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Reports Air Quality Data Reporting § 51.320 Annual air quality data report. The requirements for reporting air quality data collected...

  18. 40 CFR 52.2528 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2528 Section 52.2528 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of Sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for Preventing Significant Deterioration of Air Quality, the...

  19. 40 CFR 52.2528 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2528 Section 52.2528 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of Sections 160 through 165 of the Clean Air... Quality Deterioration. (b) Regulations for Preventing Significant Deterioration of Air Quality, the...

  20. 40 CFR 52.931 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.931 Section 52.931 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) Regulations for preventing significant deterioration of air quality. The..., the Kentucky Division for Air Quality has determined that the application complies with the...

  1. Innovations in projecting emissions for air quality modeling

    EPA Science Inventory

    Air quality modeling is used in setting air quality standards and in evaluating their costs and benefits. Historically, modeling applications have projected emissions and the resulting air quality only 5 to 10 years into the future. Recognition that the choice of air quality mana...

  2. Nursing Effort and Quality of Care for Nursing Home Residents

    ERIC Educational Resources Information Center

    Arling, Greg; Kane, Robert L.; Mueller, Christine; Bershadsky, Julie; Degenholtz, Howard B.

    2007-01-01

    Purpose: The purpose of this study was to determine the relationship between nursing home staffing level, care received by individual residents, and resident quality-related care processes and functional outcomes. Design and Methods: Nurses recorded resident care time for 5,314 residents on 156 units in 105 facilities in four states (Colorado,…

  3. TRIHALOMETHANE LEVELS IN HOME TAP WATER AND SEMEN QUALITY

    EPA Science Inventory

    Trihalomethane Levels in Home Tap Water and Semen Quality
    Laura Fenster, 1 Kirsten Waller, 2 Gayle Windham, 1 Tanya Henneman, 2 Meredith Anderson, 2 Pauline Mendola, 3 James W. Overstreet, 4 Shanna H. Swan5

    1California Department of Health Services, Division of Environm...

  4. The efficiency of home composting programmes and compost quality.

    PubMed

    Vázquez, M A; Soto, M

    2017-06-01

    The efficiency of home composting programmes and the quality of the produced compost was evaluated in eight rural areas carrying out home composting programmes (up to 880 composting bins) for all household biowaste including meat and fish leftovers. Efficiency was analysed in terms of reduction of organic waste collected by the municipal services. An efficiency of 77% on average was obtained, corresponding to a composting rate of 126kg/person·year of biowaste (or 380kg/composter·year). Compost quality was determined for a total of 90 composting bins. The operation of composting bins by users was successful, as indicated by a low C/N ratio (10-15), low inappropriate materials (or physical contaminant materials, mean of 0.27±0.44% dry matter), low heavy metal content (94% of samples met required standards for agricultural use) and high nutrient content (2.1% N, 0.6% P, 2.5% K, 0.7% Mg and 3.7% Ca on average, dry matter). The high moisture (above 70% in 48% of the samples) did not compromise the compost quality. Results of this study show that home composting of household organic waste including meat and fish leftovers is a feasible practice. Home composting helps individuals and families to reduce the amount of household waste at the same time gaining a fertiliser material (compost) of excellent quality for gardens or vegetable plots. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Nursing Effort and Quality of Care for Nursing Home Residents

    ERIC Educational Resources Information Center

    Arling, Greg; Kane, Robert L.; Mueller, Christine; Bershadsky, Julie; Degenholtz, Howard B.

    2007-01-01

    Purpose: The purpose of this study was to determine the relationship between nursing home staffing level, care received by individual residents, and resident quality-related care processes and functional outcomes. Design and Methods: Nurses recorded resident care time for 5,314 residents on 156 units in 105 facilities in four states (Colorado,…

  6. TRIHALOMETHANE LEVELS IN HOME TAP WATER AND SEMEN QUALITY

    EPA Science Inventory

    Trihalomethane Levels in Home Tap Water and Semen Quality
    Laura Fenster, 1 Kirsten Waller, 2 Gayle Windham, 1 Tanya Henneman, 2 Meredith Anderson, 2 Pauline Mendola, 3 James W. Overstreet, 4 Shanna H. Swan5

    1California Department of Health Services, Division of Environm...

  7. Indoor Air Quality: Is Increased Ventilation the Answer?

    ERIC Educational Resources Information Center

    Hansen, Shirley

    1989-01-01

    Explains how indoor air quality is affected by pollutants in the air and also by temperature, humidity, and ventilation. Increased ventilation alone seldom solves the "sick building syndrome." Lists ways to improve indoor air quality and optimize energy efficiency. (MLF)

  8. Indoor Air Quality: Is Increased Ventilation the Answer?

    ERIC Educational Resources Information Center

    Hansen, Shirley

    1989-01-01

    Explains how indoor air quality is affected by pollutants in the air and also by temperature, humidity, and ventilation. Increased ventilation alone seldom solves the "sick building syndrome." Lists ways to improve indoor air quality and optimize energy efficiency. (MLF)

  9. Developing Interoperable Air Quality Community Portals

    NASA Astrophysics Data System (ADS)

    Falke, S. R.; Husar, R. B.; Yang, C. P.; Robinson, E. M.; Fialkowski, W. E.

    2009-04-01

    Web portals are intended to provide consolidated discovery, filtering and aggregation of content from multiple, distributed web sources targeted at particular user communities. This paper presents a standards-based information architectural approach to developing portals aimed at air quality community collaboration in data access and analysis. An important characteristic of the approach is to advance beyond the present stand-alone design of most portals to achieve interoperability with other portals and information sources. We show how using metadata standards, web services, RSS feeds and other Web 2.0 technologies, such as Yahoo! Pipes and del.icio.us, helps increase interoperability among portals. The approach is illustrated within the context of the GEOSS Architecture Implementation Pilot where an air quality community portal is being developed to provide a user interface between the portals and clearinghouse of the GEOSS Common Infrastructure and the air quality community catalog of metadata and data services.

  10. Emerging Latin American air quality regulation

    SciTech Connect

    Hosmer, A.W.; Vitale, E.M.; Guerrero, C.R.; Solorzano-Vincent, L.

    1998-12-31

    Latin America is the most urbanized region in the developing world. In recent years, significant economic growth has resulted in population migration from rural areas to urban centers, as well as in a substantial rise in the standard of living within the Region. These changes have impacted the air quality of Latin American countries as increased numbers of industrial facilities and motor vehicles release pollutants into the air. With the advent of new free trade agreements such as MERCOSUR and NAFTA, economic activity and associated pollutant levels can only be expected to continue to expand in the future. In order to address growing air pollution problems, many Latin America countries including Argentina, Brazil, Chile, Columbia, Costa Rica, and Mexico have passed, or will soon pass, new legislation to develop and strengthen their environmental frameworks with respect to air quality. As a first step toward understanding the impacts that this increased environmental regulation will have, this paper will examine the regulatory systems in six Latin American countries with respect to ambient air quality and for each of these countries: review a short history of the air quality problems within the country; outline the legal and institutional framework including key laws and implementing institutions; summarize in brief the current status of the country in terms of program development and implementation; and identify projected future trends. In addition, the paper will briefly review the international treaties that have bearing on Latin American air quality. Finally, the paper will conclude by identifying and exploring emerging trends in individual countries and the region as a whole.

  11. Outdoor air pollution and sperm quality.

    PubMed

    Lafuente, Rafael; García-Blàquez, Núria; Jacquemin, Bénédicte; Checa, Miguel Angel

    2016-09-15

    Exposure to air pollution has been clearly associated with a range of adverse health effects, including reproductive toxicity, but its effects on male semen quality are still unclear. We performed a systematic review (up to June 2016) to assess the impact of air pollutants on sperm quality. We included 17 semi-ecological, panel, and cohort studies, assessing outdoor air pollutants, such as PM2.5, PM10, NOx, SO2, and O3, and their effects on DNA fragmentation, sperm count, sperm motility, and sperm morphology. Thirteen studies assessed air pollution exposure measured environmentally, and six used biomarkers of air pollution exposure (two did both). We rated the studies using the Newcastle-Ottawa Scale and assessed with the exposure method. Taking into account these factors and the number of studies finding significant results (positive or negative), the evidence supporting an effect of air pollution on DNA fragmentation is weak but suggestive, on sperm motility is limited and probably inexistent, on lower sperm count is inconclusive, and on sperm morphology is very suggestive. Because of the diversity of air pollutants and sperm parameters, and the studies' designs, we were unable to perform a meta-analysis. In summary, most studies concluded that outdoor air pollution affects at least one of the four semen quality parameters included in the review. However, results lack consistency, and furthermore, studies were not comparable. Studies using standardized air pollution and semen measures are required to obtain more reliable conclusions. CRD42015007175. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  12. Groundwater level and nitrate concentration trends on Mountain Home Air Force Base, southwestern Idaho

    USGS Publications Warehouse

    Williams, Marshall L.

    2014-01-01

    Mountain Home Air Force Base in southwestern Idaho draws most of its drinking water from the regional aquifer. The base is located within the State of Idaho's Mountain Home Groundwater Management Area and is adjacent to the State's Cinder Cone Butte Critical Groundwater Area. Both areas were established by the Idaho Department of Water Resources in the early 1980s because of declining water levels in the regional aquifer. The base also is listed by the Idaho Department of Environmental Quality as a nitrate priority area. The U.S. Geological Survey, in cooperation with the U.S. Air Force, began monitoring wells on the base in 1985, and currently monitors 25 wells for water levels and 17 wells for water quality, primarily nutrients. This report provides a summary of water-level and nitrate concentration data collected primarily between 2001 and 2013 and examines trends in those data. A Regional Kendall Test was run to combine results from all wells to determine an overall regional trend in water level. Groundwater levels declined at an average rate of about 1.08 feet per year. Nitrate concentration trends show that 3 wells (18 percent) are increasing in nitrate concentration trend, 3 wells (18 percent) show a decreasing nitrate concentration trend, and 11 wells (64 percent) show no nitrate concentration trend. Six wells (35 percent) currently exceed the U.S. Environmental Protection Agency's maximum contaminant limit of 10 milligrams per liter for nitrate (nitrite plus nitrate, measured as nitrogen).

  13. Impacts of Climate Policy on Regional Air Quality, Health, and Air Quality Regulatory Procedures

    NASA Astrophysics Data System (ADS)

    Thompson, T. M.; Selin, N. E.

    2011-12-01

    Both the changing climate, and the policy implemented to address climate change can impact regional air quality. We evaluate the impacts of potential selected climate policies on modeled regional air quality with respect to national pollution standards, human health and the sensitivity of health uncertainty ranges. To assess changes in air quality due to climate policy, we couple output from a regional computable general equilibrium economic model (the US Regional Energy Policy [USREP] model), with a regional air quality model (the Comprehensive Air Quality Model with Extensions [CAMx]). USREP uses economic variables to determine how potential future U.S. climate policy would change emissions of regional pollutants (CO, VOC, NOx, SO2, NH3, black carbon, and organic carbon) from ten emissions-heavy sectors of the economy (electricity, coal, gas, crude oil, refined oil, energy intensive industry, other industry, service, agriculture, and transportation [light duty and heavy duty]). Changes in emissions are then modeled using CAMx to determine the impact on air quality in several cities in the Northeast US. We first calculate the impact of climate policy by using regulatory procedures used to show attainment with National Ambient Air Quality Standards (NAAQS) for ozone and particulate matter. Building on previous work, we compare those results with the calculated results and uncertainties associated with human health impacts due to climate policy. This work addresses a potential disconnect between NAAQS regulatory procedures and the cost/benefit analysis required for and by the Clean Air Act.

  14. Nursing Home Medical Staff Organization: Correlates with Quality Indicators

    PubMed Central

    Katz, Paul R.; Karuza, Jurgis; Lima, Julie; Intrator, Orna

    2015-01-01

    Objectives Little is known about the relationship between how medical care is organized and delivered in nursing homes. Taking a lead from the acute care arena, we hypothesize that nursing home medical staff organization (NHMSO) is an important predictor of clinical outcomes in the nursing home. Methods A total of 202 usable surveys from a two-wave survey process using the Dillman Method were returned from medical directors who were randomly selected from the AMDA membership and were asked to fill out a survey on the structure of medical organization in their primary nursing home practice. Quality measures that are likely to be affected by physician practice patterns were culled from NH Compare and OSCAR data sets and matched to the physician surveys, i.e., long stay residents' prevalence of pain, restraint use, catheter use, pressure ulcers, pneumococcal vaccination, influenza vaccination, presence of advanced directives, prescription of antibiotics, and prevalence of depression. Results Using a series of hierarchical multiple regressions, significant R2 changes were found when the medical staff organization dimensions were added in the regressions after controlling for nursing home structural characteristics for the following outcomes: pneumococcal vaccination and restraint use. Near significant findings were noted for pain prevalence among long stay residents, catheter use and prevalence of pressure ulcers. Conclusions This study is the first to demonstrate a relationship between medical staff organizational dimensions and clinical outcomes in the nursing home setting and as such represents an initial “proof of concept.” NHMSO should be considered as a potentially important mediating or moderating variable in the quality of care equation for nursing homes. PMID:21450190

  15. Nursing home medical staff organization: correlates with quality indicators.

    PubMed

    Katz, Paul R; Karuza, Jurgis; Lima, Julie; Intrator, Orna

    2011-11-01

    Little is known about the relationship between how medical care is organized and delivered in nursing homes. Taking a lead from the acute care arena, we hypothesize that nursing home medical staff organization (NHMSO) is an important predictor of clinical outcomes in the nursing home. A total of 202 usable surveys from a 2-wave survey process using the Dillman Method were returned from medical directors who were randomly selected from the AMDA membership and were asked to fill out a survey on the structure of medical organization in their primary nursing home practice. Quality measures that are likely to be affected by physician practice patterns were culled from NH Compare and OSCAR data sets and matched to the physician surveys, ie, long stay residents' prevalence of pain, restraint use, catheter use, pressure ulcers, pneumococcal vaccination, influenza vaccination, presence of advanced directives, prescription of antibiotics, and prevalence of depression. Using a series of hierarchical multiple regressions, significant R(2) changes were found when the medical staff organization dimensions were added in the regressions after controlling for nursing home structural characteristics for the following outcomes: pneumococcal vaccination and restraint use. Near significant findings were noted for pain prevalence among long-stay residents, catheter use, and prevalence of pressure ulcers. This study is the first to demonstrate a relationship between medical staff organizational dimensions and clinical outcomes in the nursing home setting and as such represents an initial "proof of concept." NHMSO should be considered as a potentially important mediating or moderating variable in the quality of care equation for nursing homes. Copyright © 2011 American Medical Directors Association. Published by Elsevier Inc. All rights reserved.

  16. Measuring Indoor Air Quality of Hookah Lounges

    PubMed Central

    Fiala, Steven C.; Pawlak, Rebecca L.

    2012-01-01

    Many states have implemented smoke-free workplace laws to protect employees and customers from exposure to secondhand smoke. However, exemptions in these laws have allowed indoor tobacco smoking in hookah lounges to proliferate in recent years. To describe the amount of secondhand smoke in hookah lounges, we measured the indoor air quality of 10 hookah lounges in Oregon. Air quality measurements ranged from “unhealthy” to “hazardous” according to Environmental Protection Agency standards, indicating a potential health risk for patrons and employees. PMID:22994168

  17. Quality and cost of student lunches brought from home.

    PubMed

    Caruso, Michelle L; Cullen, Karen W

    2015-01-01

    The nutritional quality and cost of lunches brought from home are overlooked and understudied aspects of the school food environment. To examine the quality and cost of lunches brought from home by elementary and intermediate school students. An observational study was conducted in 12 schools (8 elementary and 4 intermediate) in one Houston, Texas, area school district from October 6, 2011, to December 5, 2011. Participants included 242 elementary and 95 intermediate school students who brought lunches from home. Lunches brought from home. Foods brought and amounts eaten were recorded along with student grade level and sex. Nutrient and food group content were calculated and compared with current National School Lunch Program (NSLP) guidelines. Per-serving prices for each item were collected from 3 grocery stores in the study area and averaged. Compared with the NSLP guidelines, lunches brought from home contained more sodium (1110 vs ≤640 mg for elementary and 1003 vs ≤710 mg for intermediate students) and fewer servings of fruits (0.33 cup for elementary and 0.29 cup for intermediate students vs 0.50 cup per the NSLP guidelines), vegetables (0.07 cup for elementary and 0.11 cup for intermediate students vs 0.75 cup per the NSLP guidelines), whole grains (0.22-oz equivalent for elementary and 0.31-oz equivalent for intermediate students vs 0.50-oz minimum per the NLSP guidelines), and fluid milk (0.08 cup for elementary and 0.02 cup for intermediate students vs 1 cup per the NSLP guidelines). About 90% of lunches from home contained desserts, snack chips, and sweetened beverages, which are not permitted in reimbursable school meals. The cost of lunches from home averaged $1.93 for elementary and $1.76 for intermediate students. Students from lower-income intermediate schools brought significantly higher-priced ($1.94) lunches than did students from middle-income schools ($1.63). Lunches brought from home compared unfavorably with current NSLP guidelines

  18. Mobile computing and the quality of home care nursing practice.

    PubMed

    Paré, Guy; Sicotte, Claude; Moreault, Marie-Pierre; Poba-Nzaou, Placide; Nahas, Georgette; Templier, Mathieu

    2011-01-01

    We investigated the effects of the introduction of mobile computing on the quality of home care nursing practice in Québec. The software, which structured and organized the nursing activities in patients' homes, was installed sequentially in nine community health centres. The completeness of the nursing notes was compared in 77 paper records (pre-implementation) and 73 electronic records (post-implementation). Overall, the introduction of the software was associated with an improvement in the completeness of the nursing notes. All 137 nurse users were asked to complete a structured questionnaire. A total of 101 completed questionnaires were returned (74% response rate). Overall, the nurses reported a very high level of satisfaction with the quality of clinical information collected. A total of 57 semi-structured interviews were conducted and most nurses believed that the new software represented a user-friendly tool with a clear and understandable structure. A postal questionnaire was sent to approximately 1240 patients. A total of 223 patients returned the questionnaire (approximately 18% response rate). Overall, patients felt that the use of mobile computing during home visits allowed nurses to manage their health condition better and, hence, provide superior care services. The use of mobile computing had positive and significant effects on the quality of care provided by home nurses.

  19. The AirQuality SenseBox

    NASA Astrophysics Data System (ADS)

    Demuth, Dustin; Nuest, Daniel; Bröring, Arne; Pebesma, Edzer

    2013-04-01

    In the past year, a group of open hardware enthusiasts and citizen scientists had large success in the crowd-funding of an open hardware-based sensor platform for air quality monitoring, called the Air Quality Egg. Via the kickstarter platform, the group was able to collect triple the amount of money than needed to fulfill their goals. Data generated by the Air Quality Egg is pushed to the data logging platform cosm.com, which makes the devices a part of the Internet of Things. The project aims at increasing the participation of citizens in the collection of data, the development of sensors, the operation of sensor stations, and, as data on cosm is publicly available, the sharing, visualization and analysis of data. Air Quality Eggs can measure NO2 and CO concentrations, as well as relative humidity and temperature. The chosen sensors are low-cost and have limited precision and accurracy. The Air Quality Egg consists of a stationary outdoor and a stationary indoor unit. Each outdoor unit will wirelessly transmit air quality measurements to the indoor unit, which forwards the data to cosm. Most recent versions of the Air Quality Egg allow a rough calibration of the gas sensors and on-the-fly conversion from raw sensor readings (impedance) to meaningful air quality data expressed in units of parts per billion. Data generated by these low-cost platforms are not intended to replace well-calibrated official monitoring stations, but rather augment the density of the total monitoring network with citizen sensors. To improve the usability of the Air Quality Egg, we present a new and more advanced concept, called the AirQuality SenseBox. We made the outdoor platform more autonomous and location-aware by adding solarpanels and rechargeable batteries as a power source. The AirQuality SenseBox knows its own position from a GPS device attached to the platform. As a mobile sensor platform, it can for instance be attached to vehicles. A low-cost and low-power wireless chipset

  20. Air Quality Monitoring and Forecasting in China

    NASA Astrophysics Data System (ADS)

    Mijling, Bas; van der A, Ronald; Wang, Pucai

    2010-05-01

    Within the ESA-MOST Dragon 2 Programme, the AMFIC project consists of an integrated system for monitoring and forecasting tropospheric pollutants over China. Satellite data, in situ measurements and chemical transport model results are used to generate consistent air quality information over China. The system includes a data archive of the recent years, near real time data, and air quality forecasts for several days ahead, which can be find on http://www.amfic.eu. Air pollutants covered are nitrogen dioxide, sulfur dioxide, formaldehyde, carbon monoxide, methane and aerosol. The AMFIC system has been used to evaluate the effect of the air quality measures which were taken by the Chinese authorities related to the Olympic Games and Paralympics in Beijing. Industrial activities and traffic in and around the city were reduced drastically to improve air quality. To compensate for the atypical meteorological conditions during the Olympic events, tropospheric NO2 column observations from GOME-2 and OMI are interpreted against simulations from the CHIMERE regional chemistry transport model. When compared with the pre-Olympic concentration levels, we find a NO2 reduction of 60% over Beijing and significant reductions in surrounding areas. After the Olympic period, NO2 concentrations slowly return to their pre-Olympic level. The satellite observations and model simulations of tropospheric NO2 column concentrations are also used to constrain NOx emissions over China by using data assimilation techniques. We will present the preliminary results of these efforts. The periodical update of the bottom-up emission inventory is expected to reveal emission trends and improve the air quality forecasts for China.

  1. Influence of Nurse Aide Absenteeism on Nursing Home Quality.

    PubMed

    Castle, Nicholas G; Ferguson-Rome, Jamie C

    2015-08-01

    In this analysis, the association of nurse aide absenteeism with quality is examined. Absenteeism is the failure of nurse aides to report for work when they are scheduled to work. Data used in this investigation came from survey responses from 3,941 nursing homes; Nursing Home Compare; the Online System for Survey, Certification and Administrative Reporting data; and the Area Resource File. Staffing characteristics, quality indicators, facility, and market information from these data sources were all measured in 2008. The specific quality indicators examined are physical restraint use, catheter use, pain management, and pressure sores using negative binomial regression. An average rate of 9.2% for nurse aide absenteeism was reported in the prior week. We find that high levels of absenteeism are associated with poor performance on all four quality indicators examined. The investigation presented, to our knowledge, is one of the first examining the implications of absenteeism in nursing homes. Absenteeism can be a costly staffing issue, one of the potential costs identified in this analysis is an impact on quality of care. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Uncertainty in Regional Air Quality Modeling

    NASA Astrophysics Data System (ADS)

    Digar, Antara

    Effective pollution mitigation is the key to successful air quality management. Although states invest millions of dollars to predict future air quality, the regulatory modeling and analysis process to inform pollution control strategy remains uncertain. Traditionally deterministic ‘bright-line’ tests are applied to evaluate the sufficiency of a control strategy to attain an air quality standard. A critical part of regulatory attainment demonstration is the prediction of future pollutant levels using photochemical air quality models. However, because models are uncertain, they yield a false sense of precision that pollutant response to emission controls is perfectly known and may eventually mislead the selection of control policies. These uncertainties in turn affect the health impact assessment of air pollution control strategies. This thesis explores beyond the conventional practice of deterministic attainment demonstration and presents novel approaches to yield probabilistic representations of pollutant response to emission controls by accounting for uncertainties in regional air quality planning. Computationally-efficient methods are developed and validated to characterize uncertainty in the prediction of secondary pollutant (ozone and particulate matter) sensitivities to precursor emissions in the presence of uncertainties in model assumptions and input parameters. We also introduce impact factors that enable identification of model inputs and scenarios that strongly influence pollutant concentrations and sensitivity to precursor emissions. We demonstrate how these probabilistic approaches could be applied to determine the likelihood that any control measure will yield regulatory attainment, or could be extended to evaluate probabilistic health benefits of emission controls, considering uncertainties in both air quality models and epidemiological concentration-response relationships. Finally, ground-level observations for pollutant (ozone) and precursor

  3. Impact of kerosene space heaters on indoor air quality.

    PubMed

    Hanoune, B; Carteret, M

    2015-09-01

    In recent years, the use of kerosene space heaters as additional or principal heat source has been increasing, because these heaters allow a continuous control on the energy cost. These devices are unvented, and all combustion products are released into the room where the heaters are operated. The indoor air quality of seven private homes using wick-type or electronic injection-type kerosene space heaters was investigated. Concentrations of CO, CO2, NOx, formaldehyde and particulate matter (0.02-10 μm) were measured, using time-resolved instruments when available. All heaters tested are significant sources of submicron particles, NOx and CO2. The average NO2 and CO2 concentrations are determined by the duration of use of the kerosene heaters. These results stress the need to regulate the use of unvented combustion appliances to decrease the exposure of people to air contaminants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Navajo coal and air quality in Shiprock, New Mexico

    USGS Publications Warehouse

    Bunnell, Joseph E.; Garcia, Linda V.

    2006-01-01

    Among the Navajo people, high levels of respiratory disease, such as asthma, exist in a population with low rates of cigarette smoking. Air quality outdoors and indoors affects respiratory health. Many Navajo Nation residents burn locally mined coal in their homes for heat, as coal is the most economical energy source. The U.S. Geological Survey and Dine College, in cooperation with the Navajo Division of Health, are conducting a study in the Shiprock, New Mexico, area to determine if indoor use of this coal might be contributing to some of the respiratory health problems experienced by the residents. Researchers in this study will (1) examine respiratory health data, (2) identify stove type and use, (3) analyze samples of coal that are used locally, and (4) measure and characterize air quality inside selected homes. This Fact Sheet summarizes the interim results of the study in both English and Navajo. This Fact Sheet is available in three versions: * English [800-KB PDF file ] * Navajo [computer must have Navajo language fonts installed - 304-KB PDF file] * Image of the Navajo language version [19.8-MB PDF file

  5. Work environment characteristics of high-quality home health agencies.

    PubMed

    Tullai-McGuinness, Susan; Riggs, Jennifer S; Farag, Amany A

    2011-10-01

    This concurrent mixed-method study examines the nurse work environment of high-quality Medicare-certified home health agencies. High-quality (n=6) and low-quality (n=6) home health agencies were recruited using agency-level publicly reported patient outcomes. Direct care registered nurses (RNs) from each agency participated in a focus group and completed the Practice Environment Scale of the Nurse Work Index (PES-NWI). No significant differences were found in the PES-NWI results between nurses working in high- and low-quality agencies, though nurses in high-quality agencies scored higher on all subscales. Nurses working in all the high-quality agencies identified themes of adequate staffing, supportive managers, and team work. These themes were not consistently identified in low-quality agencies. Themes of supportive managers and team work are reflective of effective leadership at the manager level. Agencies struggling to improve quality of care might consider developing their managers' leadership skills.

  6. Stenotrophomonas, Mycobacterium, and Streptomyces in home dust and air: Associations with moldiness and other home/family characteristics

    PubMed Central

    Kettleson, Eric; Kumar, Sudhir; Reponen, Tiina; Vesper, Stephen; Méheust, Delphine; Grinshpun, Sergey A.; Adhikari, Atin

    2013-01-01

    Respiratory illnesses have been linked to children’s exposures to water-damaged homes. Therefore, understanding the microbiome in water-damaged homes is critical to preventing these illnesses. Few studies have quantified bacterial contamination, especially specific species, in water-damaged homes. We collected air and dust samples in twenty-one low-mold homes and twenty-one high-mold homes. The concentrations of three bacteria/genera, Stenotrophomonas maltophilia, Streptomyces sp. and Mycobacterium sp., were measured in air and dust samples using quantitative PCR (QPCR). The concentrations of the bacteria measured in the air samples were not associated with any specific home characteristic based on multiple regression models. However, higher concentrations of S. maltophilia in the dust samples were associated with water damage, i.e. with higher floor surface moisture and higher concentrations of moisture-related mold species. The concentrations of Streptomyces and Mycobacterium sp. had similar patterns and may be partially determined by human and animal occupants and outdoor sources of these bacteria. PMID:23397905

  7. Can We Clear the Air about Home Schooling?

    ERIC Educational Resources Information Center

    Wilson, Stephanie

    1988-01-01

    A parent who teaches her children at home discusses the skills needed by the parent, reasons for choosing home schooling, children's opportunities for socialization, and other topics that are frequently misunderstood. (MT)

  8. Indoor air quality investigation on commercial aircraft.

    PubMed

    Lee, S C; Poon, C S; Li, X D; Luk, F

    1999-09-01

    Sixteen flights had been investigated for indoor air quality (IAQ) on Cathay Pacific aircraft from June 1996 to August 1997. In general, the air quality on Cathay Pacific aircraft was within relevant air quality standards because the average age of aircraft was less than 2 years. Carbon dioxide (CO2) levels on all flights measured were below the Federal Aviation Administration (FAA) standard (30,000 ppm). The CO2 level was substantially higher during boarding and de-boarding than cruise due to low fresh air supply. Humidity on the aircraft was low, especially for long-haul flights. Minimum humidity during cruise was below the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) minimum humidity standard (20%). The average temperature was within a comfortable temperature range of 23 +/- 2 degrees C. The vertical temperature profile on aircraft was uniform and below the International Standard Organization (ISO) standard. Carbon monoxide levels were below the FAA standard (50 ppm). Trace amount of ozone detected ranged from undetectable to 90 ppb, which was below the FAA standard. Particulate level was low for most non-smoking flights, but peaks were observed during boarding and de-boarding. The average particulate level in smoking flights (138 micrograms/m3) was higher than non-smoking flights (7.6 micrograms/m3). The impact on IAQ by switching from low-mode to high-mode ventilation showed a reduction in CO2 levels, temperature, and relative humidity.

  9. Air Quality Modeling Technical Support Document for the Final Cross State Air Pollution Rule Update

    EPA Pesticide Factsheets

    In this technical support document (TSD) we describe the air quality modeling performed to support the final Cross State Air Pollution Rule for the 2008 ozone National Ambient Air Quality Standards (NAAQS).

  10. Integration of air and water quality issues

    USDA-ARS?s Scientific Manuscript database

    The environmental sustainability of dairy farms is dependent upon a number of air and water quality issues. Atmospheric emissions include hazardous compounds such as ammonia and hydrogen sulfide along with greenhouse gases and their implications with global climate change. Runoff of sediment, phosph...

  11. Forest fuels, prescribed fire, and air quality

    Treesearch

    J. Alfred Hall

    1972-01-01

    The combustion products (smoke) from forest wildfires or prescribed burns are often considered on a par with any other emission that might affect air quality. But enough is known about smoke from woody fuels to indicate that its importance is limited almost entirely to visibility obstruction, an effect that can be minimized by proper timing and preparation for burning...

  12. The Bottom Line For Air Quality.

    ERIC Educational Resources Information Center

    Ellis, Tom

    2000-01-01

    Discusses how the right type of flooring can help schools reduce indoor-air-quality problems. Using vinyl composition flooring to handle moisture and reduce fungi growth is examined as are the benefits of vinyl cushion tufted textile flooring for cost effectiveness, learning environment improvement, installation, and effectiveness in emergencies.…

  13. AIR POLLUTION EFFECTS ON SEMEN QUALITY

    EPA Science Inventory

    The potential impact of exposure to periods of high air pollution on male reproductive health was examined within the framework of an international project conducted in the Czech Republic. Semen quality was evaluated in young men (age 18) living in the Teplice District who are ex...

  14. AIR POLLUTION EFFECTS ON SEMEN QUALITY

    EPA Science Inventory

    The potential impact of exposure to periods of high air pollution on male reproductive health was examined within the framework of an international project conducted in the Czech Republic. Semen quality was evaluated in young men (age 18) living in the Teplice District who are ex...

  15. PROMOTING AIR QUALITY THROUGH ENVIRONMENTAL TECHNOLOGY VERIFICATION

    EPA Science Inventory

    The paper discusses the promotion of improved air quality through environmental technology verifications (ETVs). In 1995, the U.S. EPA's Office of Research and Development began the ETV Program in response to President Clinton's "Bridge to a Sustainable Future" and Vice Presiden...

  16. Indoor Air Quality Guidelines for Pennsylvania Schools.

    ERIC Educational Resources Information Center

    Zimmerman, Robert S., Jr.

    This report provides information and practical guidance on how to prevent indoor air quality (IAQ) problems in schools, and it describes how to implement a practical plan of action using a minimal amount of resources. It includes general guidelines to prevent or help resolve IAQ problems, guidelines on specific indoor contaminants, recommendations…

  17. Shuttle applications in tropospheric air quality observations

    NASA Technical Reports Server (NTRS)

    Friedman, E.; Gupta, J.; Carmichael, J.

    1978-01-01

    The role which might be played by the space shuttle in obtaining data which describes the air quality of the north-eastern United States was investigated. The data requirements of users, a model for statistical interpretation of the observations, the influence of orbit parameters on the spatial and temporal sampling and an example of application of the the model were considered.

  18. OPTICAL REMOTE SENSING FOR AIR QUALITY MONITORING

    EPA Science Inventory

    The paper outlines recent developments in using optical remote sensing (ORS) instruments for air quality monitoring both for gaseous pollutants and airborne particulate matter (PM). The U.S. Environmental Protection Agency (EPA) has been using open-path Fourier transform infrared...

  19. Managing Indoor Air Quality in Schools.

    ERIC Educational Resources Information Center

    Woolums, Jennifer

    This publication examines the causes and effects of poor indoor air quality and provides information for reducing exposure to indoor contaminants in schools. It discusses the various indoor pollutants found in schools, including dust, chemical agents, gases, and volatile organic compounds; where they are found in schools; and their health effects…

  20. Lichens as bioindicators of air quality

    Treesearch

    K. Stolte; D. Mangis; R. Doty; K. Tonnessen; Laurie S.  Huckaby

    1993-01-01

    This report is the result of a workshop held in Denver, Colorado on April 9-11, 1991. It summarizes the current literature and techniques for using lichens to monitor air quality. Experts in lichenology and ecology contributed information on lichen floristics, characterization of monitoring sites, lichen species and communities, identifying lichen species...

  1. OPTICAL REMOTE SENSING FOR AIR QUALITY MONITORING

    EPA Science Inventory

    The paper outlines recent developments in using optical remote sensing (ORS) instruments for air quality monitoring both for gaseous pollutants and airborne particulate matter (PM). The U.S. Environmental Protection Agency (EPA) has been using open-path Fourier transform infrared...

  2. PROMOTING AIR QUALITY THROUGH ENVIRONMENTAL TECHNOLOGY VERIFICATION

    EPA Science Inventory

    The paper discusses the promotion of improved air quality through environmental technology verifications (ETVs). In 1995, the U.S. EPA's Office of Research and Development began the ETV Program in response to President Clinton's "Bridge to a Sustainable Future" and Vice Presiden...

  3. Indoor Air Quality Basics for Schools.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This fact sheet details important information on Indoor Air Quality (IAQ) in school buildings, problems associated with IAQ, and various prevention and problem-solving strategies. Most people spend 90 percent of their time indoors, therefore the Environmental Protection Agency ranks IAQ in the top four environmental risks to the public. The…

  4. The Bottom Line For Air Quality.

    ERIC Educational Resources Information Center

    Ellis, Tom

    2000-01-01

    Discusses how the right type of flooring can help schools reduce indoor-air-quality problems. Using vinyl composition flooring to handle moisture and reduce fungi growth is examined as are the benefits of vinyl cushion tufted textile flooring for cost effectiveness, learning environment improvement, installation, and effectiveness in emergencies.…

  5. Equivalence in Ventilation and Indoor Air Quality

    SciTech Connect

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  6. Nursing home quality, cost, staffing, and staff mix.

    PubMed

    Rantz, Marilyn J; Hicks, Lanis; Grando, Victoria; Petroski, Gregory F; Madsen, Richard W; Mehr, David R; Conn, Vicki; Zwygart-Staffacher, Mary; Scott, Jill; Flesner, Marcia; Bostick, Jane; Porter, Rose; Maas, Meridean

    2004-02-01

    The purpose of this study was to describe the processes of care, organizational attributes, cost of care, staffing level, and staff mix in a sample of Missouri homes with good, average, and poor resident outcomes. A three-group exploratory study design was used, with 92 nursing homes randomly selected from all nursing homes in Missouri and classified into resident outcome groups. Resident outcomes were measured by use of quality indicators derived from nursing home Minimum Data Set resident assessment data. Cost and staffing information were derived from Medicaid cost reports. Participant observation methods were used to describe the care delivery processes. In facilities with good resident outcomes, there are basics of care and processes surrounding each that staff consistently do: helping residents with ambulation, nutrition and hydration, and toileting and bowel regularity; preventing skin breakdown; and managing pain. The analysis revealed necessary organizational attributes that must be in place in order for those basics of care to be accomplished: consistent nursing and administrative leadership, the use of team and group processes, and an active quality improvement program. The only facility characteristic across the outcome groups that was significantly different was the number of licensed beds, with smaller facilities having better outcomes. No significant differences in costs, staffing, or staff mix were detected across the groups. A trend in higher total costs of 13.58 dollars per resident per day was detected in the poor-outcome group compared with the good-outcome group. For nursing homes to achieve good resident outcomes, they must have leadership that is willing to embrace quality improvement and group process and see that the basics of care delivery are done for residents. Good quality care may not cost more than poor quality care; there is some evidence that good quality care may cost less. Small facilities of 60 beds were more likely to have good

  7. 30 CFR 550.302 - Definitions concerning air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Definitions concerning air quality. 550.302... § 550.302 Definitions concerning air quality. For purposes of §§ 550.303 and 550.304 of this part: Air... established, pursuant to section 109 of the Clean Air Act, national primary or secondary ambient air...

  8. 30 CFR 550.302 - Definitions concerning air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Definitions concerning air quality. 550.302... § 550.302 Definitions concerning air quality. For purposes of §§ 550.303 and 550.304 of this part: Air... established, pursuant to section 109 of the Clean Air Act, national primary or secondary ambient air...

  9. 40 CFR 52.1116 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1116 Section 52.1116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) The following provisions of 40 CFR 52.21 are hereby incorporated and made a...

  10. 40 CFR 52.1485 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.1485 Section 52.1485 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... include approvable procedures for preventing the significant deterioration of air quality. (b) Regulation...

  11. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  12. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  13. 40 CFR 52.1116 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1116 Section 52.1116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) The following provisions of 40 CFR 52.21 are hereby incorporated and made a...

  14. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  15. 40 CFR 52.2303 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.2303 Section 52.2303 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The plan submitted by Texas is approved as meeting the requirements of part C, Clean Air Act for preventing significant deterioration of air quality. The plan...

  16. 40 CFR 52.2303 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.2303 Section 52.2303 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The plan submitted by Texas is approved as meeting the requirements of part C, Clean Air Act for preventing significant deterioration of air quality. The plan...

  17. 40 CFR 52.1116 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1116 Section 52.1116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) The following provisions of 40 CFR 52.21 are hereby incorporated and made a...

  18. 40 CFR 52.833 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.833 Section 52.833 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are met... for preventing significant deterioration of air quality. The provisions of § 52.21 except paragraph (a...

  19. 40 CFR 52.432 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Significant deterioration of air quality. 52.432 Section 52.432 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) (b) Regulation for preventing significant deterioration of air quality. The...

  20. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  1. 40 CFR 52.1485 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.1485 Section 52.1485 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... include approvable procedures for preventing the significant deterioration of air quality. (b) Regulation...

  2. 40 CFR 52.1485 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.1485 Section 52.1485 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... include approvable procedures for preventing the significant deterioration of air quality. (b) Regulation...

  3. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  4. 40 CFR 52.683 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.683 Section 52.683 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The State of Idaho Rules for Control of Air Pollution in Idaho, specifically... quality. (b) The requirements of sections 160 through 165 of the Clean Air Act are not met for Indian...

  5. 40 CFR 52.833 - Significant deterioration of air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quality. 52.833 Section 52.833 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are met... for preventing significant deterioration of air quality. The provisions of § 52.21 except paragraph (a...

  6. 40 CFR 52.2303 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.2303 Section 52.2303 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The plan submitted by Texas is approved as meeting the requirements of part C, Clean Air Act for preventing significant deterioration of air quality. The plan...

  7. 40 CFR 52.2303 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.2303 Section 52.2303 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The plan submitted by Texas is approved as meeting the requirements of part C, Clean Air Act for preventing significant deterioration of air quality. The plan...

  8. 40 CFR 52.833 - Significant deterioration of air quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality. 52.833 Section 52.833 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are met... for preventing significant deterioration of air quality. The provisions of § 52.21 except paragraph (a...

  9. 40 CFR 52.1485 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1485 Section 52.1485 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... include approvable procedures for preventing the significant deterioration of air quality. (b) Regulation...

  10. 40 CFR 52.1116 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.1116 Section 52.1116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) The following provisions of 40 CFR 52.21 are hereby incorporated and made a...

  11. 40 CFR 52.833 - Significant deterioration of air quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality. 52.833 Section 52.833 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are met... for preventing significant deterioration of air quality. The provisions of § 52.21 except paragraph (a...

  12. 40 CFR 52.1485 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1485 Section 52.1485 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... include approvable procedures for preventing the significant deterioration of air quality. (b) Regulation...

  13. 40 CFR 52.833 - Significant deterioration of air quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality. 52.833 Section 52.833 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air Act are met... for preventing significant deterioration of air quality. The provisions of § 52.21 except paragraph (a...

  14. 40 CFR 52.1116 - Significant deterioration of air quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality. 52.1116 Section 52.1116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Significant deterioration of air quality. (a) The requirements of sections 160 through 165 of the Clean Air... deterioration of air quality. (b) The following provisions of 40 CFR 52.21 are hereby incorporated and made a...

  15. 30 CFR 250.302 - Definitions concerning air quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Definitions concerning air quality. 250.302... Pollution Prevention and Control § 250.302 Definitions concerning air quality. For purposes of §§ 250.303... secondary ambient air quality standards. Attainment area means, for any air pollutant, an area which...

  16. Quality of care in nursing homes: an analysis of relationships among profit, quality, and ownership.

    PubMed

    O'Neill, Ciaran; Harrington, Charlene; Kitchener, Martin; Saliba, Debra

    2003-12-01

    Recent work has highlighted a negative correlation between proprietary status and nursing home quality of care. This relationship might be explained by the context in which proprietary homes operate. However, another possible explanation is that some proprietary homes take excessive profit to the detriment of care quality. To examine the relationship between profit levels and quality in proprietary and nonproprietary nursing homes (NHs), accounting for resident and market characteristics. Data on 1098 free-standing NHs were taken from the California Office of Statewide Health Planning and Development, the On-line Survey Certification and Reporting System, and California licensing and statistical reports for 1998 and 1999. Tobit multivariate techniques were used to examine the relationship between deficiency citations and a range of explanatory variables, including profit. Proprietary homes in California had significantly lower quality of care than nonproprietary homes. A stratified analysis revealed that, controlling for resident, facility, and market characteristics, profits located within the highest 14% of the proprietary sector's profit distribution were associated with significantly more total deficiencies and serious deficiencies. This relationship was not found in nonproprietary facilities. Other factors related to deficiencies included the ethnic mix of residents and facility size. Within the context in which proprietary homes operate, profit above a given threshold is associated with a higher number of deficiencies. Given this and the role of the proprietary sector in NH care, careful monitoring of profit levels in this sector appears warranted.

  17. An Analysis of Nursing Home Quality Measures and Staffing

    PubMed Central

    Alexander, Gregory L.

    2010-01-01

    Purpose The purpose of this retrospective study was to evaluate nursing home quality measures (QMs) available in a national database called Nursing Home Compare. The aim was to determine whether differences in QM scores occurred with changing staffing-level mix. Subjects All Missouri nursing home facilities were included for the analysis of the 14 QMs downloaded in February 2004. Methods Analyses of variance were used to examine differences in the dependent QM scores; the independent range of staffing levels for 3 disciplines, certified nurse assistant (CNA), licensed practical nurse (LPN), and registered nurse (RN), was analyzed on the basis of their number of hours per resident per day worked in the nursing home. Planned contrasts and post hoc Bonferroni adjustments were calculated to further evaluate significance levels. Finally, residents were used as a covariate to determine effects on significant analyses of variance. Results Care is proportionate to the percentage of CNA/LPN/RN staffing-level mix, with 2 long-stay QMs (percentage of residents who lose bowel or bladder control and percentage of residents whose need for help with activities of daily living has increased) and 2 short-stay measures (percentage of residents who had moderate to severe pain and percentage of residents with pressure ulcers) revealed differences in mean quality scores when staffing levels changed. PMID:18641507

  18. Design and implementation air quality monitoring robot

    NASA Astrophysics Data System (ADS)

    Chen, Yuanhua; Li, Jie; Qi, Chunxue

    2017-01-01

    Robot applied in environmental protection can break through the limitations in working environment, scope and mode of the existing environmental monitoring and pollution abatement equipments, which undertake the innovation and improvement in the basin, atmosphere, emergency and pollution treatment facilities. Actually, the relevant technology is backward with limited research and investment. Though the device companies have achieved some results in the study on the water quality monitoring, pipeline monitoring and sewage disposal, this technological progress on the whole is still much slow, and the mature product has not been formed. As a result, the market urges a demand of a new type of device which is more suitable for environmental protection on the basis of robot successfully applied in other fields. This paper designs and realizes a tracked mobile robot of air quality monitoring, which can be used to monitor air quality for the pollution accident in industrial parks and regular management.

  19. A new air quality monitoring and early warning system: Air quality assessment and air pollutant concentration prediction.

    PubMed

    Yang, Zhongshan; Wang, Jian

    2017-10-01

    Air pollution in many countries is worsening with industrialization and urbanization, resulting in climate change and affecting people's health, thus, making the work of policymakers more difficult. It is therefore both urgent and necessary to establish amore scientific air quality monitoring and early warning system to evaluate the degree of air pollution objectively, and predict pollutant concentrations accurately. However, the integration of air quality assessment and air pollutant concentration prediction to establish an air quality system is not common. In this paper, we propose a new air quality monitoring and early warning system, including an assessment module and forecasting module. In the air quality assessment module, fuzzy comprehensive evaluation is used to determine the main pollutants and evaluate the degree of air pollution more scientifically. In the air pollutant concentration prediction module, a novel hybridization model combining complementary ensemble empirical mode decomposition, a modified cuckoo search and differential evolution algorithm, and an Elman neural network, is proposed to improve the forecasting accuracy of six main air pollutant concentrations. To verify the effectiveness of this system, pollutant data for two cities in China are used. The result of the fuzzy comprehensive evaluation shows that the major air pollutants in Xi'an and Jinan are PM10 and PM2.5 respectively, and that the air quality of Xi'an is better than that of Jinan. The forecasting results indicate that the proposed hybrid model is remarkably superior to all benchmark models on account of its higher prediction accuracy and stability. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Making sense of US air quality

    NASA Astrophysics Data System (ADS)

    Jacob, D.

    2016-12-01

    Air pollution is the number one environmental killer in the world. In the US, vigorous emission control policies have led to significant improvements in air quality over the past two decades. However, current levels of surface ozone and particulate matter (PM) still exceed air quality standards to protect public health. Meeting the standards is problematic. Major gaps remain in our understanding of the processes producing ozone and PM, the role of background, and the sources contributing to that background. I will discuss recent work to address these gaps using observations from field campaigns and satellites. I will also discuss emerging issues of nitrogen and mercury deposition, which require improved understanding of sources and source-receptor relationships including a biogeochemical perspective. Air quality and climate policy are increasingly intertwined, and I will present current work to better understand US methane emissions and their trends using observations from space. I will show how new satellite observations hold promise for monitoring methane emissions on the national scale and down to the scale of point sources.