Hardware Evaluation of the Horizontal Exercise Fixture with Weight Stack
NASA Technical Reports Server (NTRS)
Newby, Nate; Leach, Mark; Fincke, Renita; Sharp, Carwyn
2009-01-01
HEF with weight stack seems to be a very sturdy and reliable exercise device that should function well in a bed rest training setting. A few improvements should be made to both the hardware and software to improve usage efficiency, but largely, this evaluation has demonstrated HEF's robustness. The hardware offers loading to muscles, bones, and joints, potentially sufficient to mitigate the loss of muscle mass and bone mineral density during long-duration bed rest campaigns. With some minor modifications, the HEF with weight stack equipment provides the best currently available means of performing squat, heel raise, prone row, bench press, and hip flexion/extension exercise in a supine orientation.
NASA Technical Reports Server (NTRS)
Wickman, Jerry L.; Kundu, Nikhil K.
1996-01-01
This laboratory exercise seeks to develop a cost effective prototype development. The exercise has the potential of linking part design, CAD, mold development, quality control, metrology, mold flow, materials testing, fixture design, automation, limited parts production and other issues as related to plastics manufacturing.
Slit scan radiographic system for intermediate size rocket motors
NASA Astrophysics Data System (ADS)
Bernardi, Richard T.; Waters, David D.
1992-12-01
The development of slit-scan radiography capability for the NASA Advanced Computed Tomography Inspection System (ACTIS) computed tomography (CT) scanner at MSFC is discussed. This allows for tangential case interface (bondline) inspection at 2 MeV of intermediate-size rocket motors like the Hawk. Motorized mounting fixture hardware was designed, fabricated, installed, and tested on ACTIS. The ACTIS linear array of x-ray detectors was aligned parallel to the tangent line of a horizontal Hawk motor case. A 5 mm thick x-ray fan beam was used. Slit-scan images were produced with continuous rotation of a horizontal Hawk motor. Image features along Hawk motor case interfaces were indicated. A motorized exit cone fixture for ACTIS slit-scan inspection was also provided. The results of this SBIR have shown that slit scanning is an alternative imaging technique for case interface inspection. More data is required to qualify the technique for bondline inspection.
NASA Technical Reports Server (NTRS)
Newby, Nathaniel J.; Scott-Pandorf, M. M.; Caldwell, E.; DeWitt, J.K.; Fincke, R.; Peters, B.T.
2010-01-01
NASA and Wyle engineers constructed a Horizontal Exercise Fixture (HEF) that was patented in 2006. Recently modifications were made to HEF with the goal of creating a device that mimics squat exercise on the Advanced Resistive Exercise Device (ARED) and can be used by bed rest subjects who must remain supine during exercise. This project posed several engineering challenges, such as how best to reproduce the hip motions (we used a sled that allowed hip motion in the sagittal plane), how to counterweight the pelvis against gravity (we used a pulley and free-weight mechanism), and how to apply large loads (body weight plus squat load) to the shoulders while simultaneously supporting the back against gravity (we tested a standard and a safety bar that allowed movement in the subject s z-axis, both of which used a retractable plate for back support). METHODS An evaluation of the HEF was conducted with human subjects (3F, 3M), who performed sets of squat exercises of increasing load from 10-repetition maximum (RM) up to 1-RM. Three pelvic counterweight loads were tested along with each of the two back-support squat bars. Data collection included 3-dimensional ground reaction forces (GRF), muscle activation (EMG), body motion (video-based motion capture), and subjective comments. These data were compared with previous ground-based ARED study data. RESULTS All subjects in the evaluation were able to perform low- to high-loading squats on the HEF. Four of the 6 subjects preferred a pelvic counterweight equivalent to 60 percent of their body weight. Four subjects preferred the standard squat bar, whereas 2 female subjects preferred the safety bar. EMG data showed muscle activation in the legs and low back typical of squat motion. GRF trajectories and eccentric-concentric loading ratios were similar to ARED. CONCLUSION: Squat exercise performed on HEF approximated squat exercise on ARED.
Portable Life Support Stretcher Unit (PLSSU) Environmental Tests: Preproduction Model.
1982-06-01
fixture was taken out by fluttering of the castering wheels since the securing straps were too soft to transmit the motion. At higher frequencies, it was...5 3.3 Proof Tests . . . 6 3.4 Vibration Tests . . . 9 3.4.1 General . . . 9 3.4.2 Pretest Inspection . . . 12 3.4.3 Vertical Vibration on Wheels ...14 3.4.4 Horizontal Vibration on Wheels . . . 15 3.4.5 Horizontal Vibration with Handle Suspension . . . 16 3.4.6 Vertical Vibration with Handle
24 CFR 3280.610 - Drainage systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... foot, when a full size cleanout is installed at the upper end. [40 FR 58752, Dec. 18, 1975... shall be designed to provide for a 1/4 inch per foot grade in horizontal piping. (i) Fittings for screw..., correctly located according to the size and type of fixture to be connected. (1) Water closet connection...
16 CFR 1510.4 - Test procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test procedure. 1510.4 Section 1510.4... REQUIREMENTS FOR RATTLES § 1510.4 Test procedure. Place the test fixture shown in Figure 1 on a horizontal plane surface. Under its own weight and in a non-compressed state apply any portion of the test sample...
Fabrication of a prototype dipole for the SSC Low Energy Booster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, C.M.
1993-12-01
The Low Energy Booster of the Superconducting Super Collider (SSC) will be a synchrotron containing 96 dipoles operating between 0.13 T and 1.35 T at 10 Hz. Each dipole`s 1.865 m-long core is made from {approximately}2900 steel laminations (lams), each 52 {times} 66 cm and 0.635 mm thick. A need to minimize power supply costs and stringent field specifications led to a straight core with very tight mechanical tolerances of the order of 0.05 mm. To satisfy these tolerances, we decided to stack the core in a vertical position; i.e., with the laminations laid horizontally. We designed and built anmore » unusual vertical stacking fixture that pivots into a horizontal position after all the laminations have been stacked and compressed and four support angles welded onto the laminations. The stacking fixture, our experience using it, and conclusions as to the merits of stacking such a long core vertically will be described. The methods of insulating and potting the pancake coils and their installation into the unsplittable core is also described.« less
Heating equipment installation system
Meuschke, Robert E.; Pomaibo, Paul P.
1991-01-01
A method for installing a heater unit assembly (52, 54) in a reactor pressure vessel (2) for performance of an annealing treatment on the vessel (2), the vessel (2) having a vertical axis, being open at the top, being provided at the top with a flange (6) having a horizontal surface, and being provided internally, at a location below the flange (6), with orientation elements (8) which are asymmetrical with respect to the vertical axis, by the steps of: providing an orientation fixture (10) having an upwardly extending guide member (18) and orientation elements (14, 16) and installing the orientation fixture (10) in the vessel (2) so that the orientation elements (14,16) of the orientation fixture (10) mate with the orientation elements (8) of the pressure vessel (2) in order to establish a defined position of the orientation fixture (10) in the pressure vessel (2), and so that the guide member (18) projects above the pressure vessel (2) flange (6); placing a seal ring (30) in a defined position on the pressure vessel (2) flange (6) with the aid of the guide member (18); mounting at least one vertical, upwardly extending guide stud (40) upon the seal ring (30); withdrawing the orientation fixture (10) from the pressure vessel (2); and moving the heater unit assembly (52,54) vertically downwardly into the pressure vessel (2) while guiding the heater unit assembly (52,54) along a path with the aid of the guide stud (40).
Elastic-Tether Suits for Artificial Gravity and Exercise
NASA Technical Reports Server (NTRS)
Torrance, Paul; Biesinger, Paul; Rybicki, Daniel D.
2005-01-01
Body suits harnessed to systems of elastic tethers have been proposed as means of approximating the effects of normal Earth gravitation on crewmembers of spacecraft in flight to help preserve the crewmembers physical fitness. The suits could also be used on Earth to increase effective gravitational loads for purposes of athletic training. The suit according to the proposal would include numerous small tether-attachment fixtures distributed over its outer surface so as to distribute the artificial gravitational force as nearly evenly as possible over the wearer s body. Elastic tethers would be connected between these fixtures and a single attachment fixture on a main elastic tether that would be anchored to a fixture on or under a floor. This fixture might include multiple pulleys to make the effective length of the main tether great enough that normal motions of the wearer cause no more than acceptably small variations in the total artificial gravitational force. Among the problems in designing the suit would be equalizing the load in the shoulder area and keeping tethers out of the way below the knees to prevent tripping. The solution would likely include running tethers through rings on the sides. Body suits with a weight or water ballast system are also proposed for very slight spinning space-station scenarios, in which cases the proposed body suits will easily be able to provide the equivalency of a 1-G or even greater load.
1971-12-01
Workmen at the Martin Marietta Corporation's Space Center facility in Denver, Colorado, lower the Skylab Multiple Docking Adapter (MDA) flight article into the horizontal rotation fixture in preparation for the crew compartment and function review. Designed and manufactured by the Marshall Space Flight Center and outfitted by Martin Marietta, the MDA housed a number of experiment control and stowage units and provided a docking port for the Apollo Command Module.
NASA Technical Reports Server (NTRS)
Caldwell, E. E.; Newby, N. J.; Ploutz-Snyder, L.
2014-01-01
The 0-G ARED squat under loads the legs relative to the 1g ARED squat. In 1g the knee extensor/flexor muscles are primarily engaged due to the body's center of gravity is behind the knees during the motion of the squat. As body weight does not play a sufficient role 0 G, a crewmember's load exposure is limited by the load delivered by ARED through the exercise bar. Prescription loads for lowerbody resistance exercise in microgravity aim to include 1-G exercise bar load in addition to the crewmember's Earth body weight (BW); however, pressure points from the bar and the 1BW increased load at the shoulders translating to higher loads on the back have been a historical limitation for shoulders, requiring a decrease in exercise load at the start of the mission. Analogous to crewmembers, bed rest subjects report limitations of exercising with high loads on the back while performing squats on the horizontal exercise fixture (HEF), a custom exercise device that serves as an analog to 0-G ARED. Improvements for increasing loads on the HEF squat were suggested by distributing total exercise load between the hips and the bar1. The same is recommended for the 0-G ARED squat, with using current equipment on the ISS, which include the T2 running harness and T2 bungees. Quantification of this improvement has been accessed through computational modeling. The purpose of this study is to characterize joint torque during a squat with a distribution in exercise load on the ARED in 0 G. The analysis used existing models from NASA's Digital Astronaut Project. The biomechanics squat model was integrated with the ARED model and T2 bungees. The spring constant for the bungees were derived from ground testing. Forward dynamic simulation was performed for various conditions including anchor point attachments on the footplate of the ARED, bar load, hip load, and gravitational environment. The model confirms joint torques at knees is lower relative to 1G conditions primarily because the load delivery system is just with the exercise bar in 0 G. By distributing partial loads through use of the bungees to the hips joint-torque profiles were altered during a squat and provided options to enhance targeting lower-body loading in aims as for an improved countermeasure.
Lee, Dong-Kyu; Kang, Min-Hyeok; Kim, Ji-Won; Kim, Yang-Gon; Park, Ji-Hyuk; Oh, Jae-Seop
2013-01-01
Abdominal strengthening exercises are important for stroke patients; however, there is a lack of research on therapeutic exercises for increasing abdominal muscle activity in stroke patients. We investigated the effects of non-paretic arm exercises using a tubing band on abdominal muscle activity in stroke patients. In total, 18 hemiplegic subjects (13 males, 5 females) were recruited. All subjects performed non-paretic arm exercises involving three different shoulder movements (extension, flexion, and horizontal abduction) using an elastic tubing band. Surface electromyography (EMG) signals were recorded from the rectus abdominis (RA), external oblique (EO), and internal oblique (IO) muscles bilaterally during non-paretic arm exercises. EMG activities of abdominal muscles during non-paretic arm extension and horizontal abduction were increased significantly versus shoulder flexion when subjects performed the arm exercise in a seated position. Muscle activity of the EO was significantly greater in the paretic than the non-paretic side during non-paretic arm extension and horizontal abduction. We suggest that non-paretic arm extension and horizontal abduction exercises using an elastic tubing band may be effective in increasing abdominal muscle activity.
1971-07-01
Workmen at the Martin Marietta Corporation's Space Center in Denver, Colorado, position Skylab's Multiple Docking Adapter (MDA) flight article in the horizontal transportation fixture. Designed and manufactured by the Marshall Space Flight Center and outfitted by Martin Marietta, the MDA housed the control units for the Apollo Telescope Mount (ATM), Earth Resources Experiment Package (EREP), and Zero-Gravity Materials Processing Facility and provided a docking port for the Apollo Command Module.
Kinetic Analysis of Horizontal Plyometric Exercise Intensity.
Kossow, Andrew J; Ebben, William P
2018-05-01
Kossow, AJ, DeChiara, TG, Neahous, SM, and Ebben, WP. Kinetic analysis of horizontal plyometric exercise intensity. J Strength Cond Res 32(5): 1222-1229, 2018-Plyometric exercises are frequently performed as part of a strength and conditioning program. Most studies assessed the kinetics of plyometric exercises primarily performed in the vertical plane. The purpose of this study was to evaluate the multiplanar kinetic characteristics of a variety of plyometric exercises, which have a significant horizontal component. This study also sought to assess sex differences in the intensity progression of these exercises. Ten men and 10 women served as subjects. The subjects performed a variety of plyometric exercises including the double-leg hop, standing long jump, single-leg standing long jump, bounding, skipping, power skipping, cone hops, and 45.72-cm hurdle hops. Subjects also performed the countermovement jump for comparison. All plyometric exercises were evaluated using a force platform. Dependent variables included the landing rate of force development and landing ground reaction forces for each exercise in the vertical, frontal, and sagittal planes. A 2-way mixed analysis of variance with repeated-measures for plyometric exercise type demonstrated main effects for exercise type for all dependent variables (p ≤ 0.001). There was no significant interaction between plyometric exercise type and sex for any of the variable assessed. Bonferroni-adjusted pairwise comparisons identified a number of differences between the plyometric exercises for the dependent variables assessed (p ≤ 0.05). These findings should be used to guide practitioners in the progression of plyometric exercise intensity, and thus program design, for those who require significant horizontal power in their sport.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, L; Allan, E; Putten, M Van
Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and verticalmore » film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.« less
Project NEO Specific Impulse Testing Solutions
NASA Technical Reports Server (NTRS)
Baffa, Bill
2018-01-01
The Neo test stand is currently configured to fire a horizontally mounted rocket motor with up to 6500 lbf thrust. Currently, the Neo test stand can measure flow of liquid propellant and oxidizer, pressures residing in the closed system up to the combustion chamber. The current configuration does not have the ability to provide all data needed to compute specific impulse. This presents three methods to outfit the NEO test fixture with instrumentation allowing for calculation of specific impulse.
Kawonga, Mary; Fonn, Sharon; Blaauw, Duane
2013-01-01
Background In light of an increasing global focus on health system strengthening and integration of vertical programmes within health systems, methods and tools are required to examine whether general health service managers exercise administrative authority over vertical programmes. Objective To measure the extent to which general health service (horizontal) managers, exercise authority over the HIV programme's monitoring and evaluation (M&E) function, and to explore factors that may influence this exercise of authority. Methods This cross-sectional survey involved interviews with 51 managers. We drew ideas from the concept of ‘exercised decision-space’ – traditionally used to measure local level managers’ exercise of authority over health system functions following decentralisation. Our main outcome measure was the degree of exercised authority – classified as ‘low’, ‘medium’ or ‘high’ – over four M&E domains (HIV data collection, collation, analysis, and use). We applied ordinal logistic regression to assess whether actor type (horizontal or vertical) was predictive of a higher degree of exercised authority, independent of management capacity (training and experience), and M&E knowledge. Results Relative to vertical managers, horizontal managers had lower HIV M&E knowledge, were more likely to exercise a higher degree of authority over HIV data collation (OR 7.26; CI: 1.9, 27.4), and less likely to do so over HIV data use (OR 0.19; CI: 0.05, 0.84). A higher HIV M&E knowledge score was predictive of a higher exercised authority over HIV data use (OR 1.22; CI: 0.99, 1.49). There was no association between management capacity and degree of authority. Conclusions This study demonstrates a HIV M&E model that is neither fully vertical nor integrated. The HIV M&E is characterised by horizontal managers producing HIV information while vertical managers use it. This may undermine policies to strengthen integrated health system planning and management under the leadership of horizontal managers. PMID:23364092
Kawonga, Mary; Fonn, Sharon; Blaauw, Duane
2013-01-24
In light of an increasing global focus on health system strengthening and integration of vertical programmes within health systems, methods and tools are required to examine whether general health service managers exercise administrative authority over vertical programmes. To measure the extent to which general health service (horizontal) managers, exercise authority over the HIV programme's monitoring and evaluation (M&E) function, and to explore factors that may influence this exercise of authority. This cross-sectional survey involved interviews with 51 managers. We drew ideas from the concept of 'exercised decision-space' - traditionally used to measure local level managers' exercise of authority over health system functions following decentralisation. Our main outcome measure was the degree of exercised authority - classified as 'low', 'medium' or 'high' - over four M&E domains (HIV data collection, collation, analysis, and use). We applied ordinal logistic regression to assess whether actor type (horizontal or vertical) was predictive of a higher degree of exercised authority, independent of management capacity (training and experience), and M&E knowledge. Relative to vertical managers, horizontal managers had lower HIV M&E knowledge, were more likely to exercise a higher degree of authority over HIV data collation (OR 7.26; CI: 1.9, 27.4), and less likely to do so over HIV data use (OR 0.19; CI: 0.05, 0.84). A higher HIV M&E knowledge score was predictive of a higher exercised authority over HIV data use (OR 1.22; CI: 0.99, 1.49). There was no association between management capacity and degree of authority. This study demonstrates a HIV M&E model that is neither fully vertical nor integrated. The HIV M&E is characterised by horizontal managers producing HIV information while vertical managers use it. This may undermine policies to strengthen integrated health system planning and management under the leadership of horizontal managers.
Articulating Support for Horizontal Resistive Exercise
NASA Technical Reports Server (NTRS)
Gundo, Daniel; Schaffner, Grant; Bentley, Jason; Loehr, James A.
2005-01-01
A versatile mechanical device provides support for a user engaged in any of a variety of resistive exercises in a substantially horizontal orientation. The unique features and versatility of the device promise to be useful in bedrest studies, rehabilitation, and specialized strength training. The device affords a capability for selectively loading and unloading of portions of the user s body through its support mechanisms, so that specific parts of the body can be trained with little or no effect on other parts that may be disabled or in the process of recovery from injury. Thus, the device is ideal for rehabilitation exercise programs prescribed by physicians and physical therapists. The capability for selective loading and support also offers potential benefits to strength and conditioning trainers and athletes who wish to selectively strengthen selected parts. The principal innovative aspect of the device is that it supports the subject s weight while enabling the subject, lying substantially horizontally, to perform an exercise that closely approximates a full standing squat. The device includes mechanisms that support the subject in such a way that the hips are free to translate both horizontally and vertically and are free to rotate about the line connecting the hips. At the same time, the shoulders are free to translate horizontally while the upper back is free to rotate about the line connecting the shoulders. Among the mechanisms for hip motion and support is a counterbalance that offsets the weight of the subject as the subject s pelvis translates horizontally and vertically and rotates the pelvis about the line connecting the hips. The counterbalance is connected to a pelvic support system that allows these pelvic movements. The subject is also supported at the shoulder by a mechanism that can tilt to provide continuous support of the upper back while allowing the rotation required for arching the back as the pelvis is displaced. The shoulder support also affords a capability for horizontal motion, and acts as the point of attachment of a load that is provided for squat and heel-raise exercises. The device is compatible with any resistive-exercise machine that provides bilateral loading via a moving cable or other mechanical linkage. The hip-translation and shoulder-translation and -rotation degrees of freedom of the supports can be locked individually or in combination in order to support the subject as necessary for exercises other than the standing squat. If necessary, for such exercises, the load can be applied directly to the subject by use of various attachments. In addition to the aforementioned heel raise, such exercises include the upright row, leg press, curls, extension of the triceps, front raise, lateral raise, and rear raise.
Army Illumination Model v2 User’s Manual
2011-09-01
Fraction of city luminosity escaping above the horizontal from lamp fixtures 10–15% suggested month4 integer Month of year 2 digits day4 integer Day...of month 2 digits yr4 integer Year 4 digits utc4 real UTC time of observer Equivalent to Zulu or GMT 4 Table 1. AIM input values, their...from 0.10 to 0.15. 2.1.4 Record 4 2.1.4.1 Date and Time The month (1–12), day (1–31), 4- digit year and coordinated universal time (UTC) for the
Processor and method for developing a set of admissible fixture designs for a workpiece
Brost, R.C.; Goldberg, K.Y.; Wallack, A.S.; Canny, J.
1996-08-13
A fixture process and method is provided for developing a complete set of all admissible fixture designs for a workpiece which prevents the workpiece from translating or rotating. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vice is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs. 27 figs.
Processor and method for developing a set of admissible fixture designs for a workpiece
Brost, Randolph C.; Goldberg, Kenneth Y.; Wallack, Aaron S.; Canny, John
1996-01-01
A fixture process and method is provided for developing a complete set of all admissible fixture designs for a workpiece which prevents the workpiece from translating or rotating. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vice is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs.
NASA Technical Reports Server (NTRS)
Figueroa, Fernando
1999-01-01
It is hypothesized that bone loss experienced by astronauts in zero gravity conditions may be curtailed by appropriate exercise. According to Wolf's law, bone regenerates when muscles produce stresses by pulling on the bone during daily activity and/or exercise on Earth. To use this theory to prevent or decrease bone loss, one needs to quantify musculoskeletal loads and relate them to bone density changes. In the context of the space program, it is desirable to determine musculoskeletal loads during exercise so that one may make similar measurements on Earth and in space. In this manner, load measurements on Earth may be used as reference to generate similar loads during exercise in space. A research project to investigate the effects of high-resistive exercise to decrease bone density loss underzero-gravity conditions is being carried out in Life Sciences Research Laboratories at NASA JSC. The project consists of a bed-rest study whereby subjects remain in horizontal position for seventeen weeks. During the study, a subset of those subjects executes a regime of resistive exercises in the horizontal exercise machine (HEM). The HEM was designed so that subjects remain horizontal while exercising to minimize gravity loading even during exercise. Bone density of each subject is measured throughout the duration of their participation. The objective of the study is to determine if the resistive exercises are effective in diminishing or eliminating bone loss. My participation in this project relates to instrumentation, measurement, and processing of signals from displacement sensors (optical encoders) and load-cells. Measurement of displacements will be used to determine the motion of the body during exercise, and load measurements will be used (along with displacement data) to determine forces and torques exerted on each section of the body during exercise. Further, I have assisted in specifying new sensors to be added to the HEM and to a new prototype resistive exercise machine called the Interim Resistive Exercise Device (IRED). New load cells and encoders should be mounted in these devices to obtain more complete kineto-dynamic information. This report includes a description of the instrumentation that was built to perform measurements in the HEM and the IRED, along with the software that was developed to collect the measurements. It also includes examples of measurements taken in the HEM. Finally, a plan is laid out that describes how these measurements may be used to determine forces exerted by muscles for each exercise.
Processor and method for developing a set of admissible fixture designs for a workpiece
Brost, Randolph C.; Goldberg, Kenneth Y.; Canny, John; Wallack, Aaron S.
1999-01-01
Methods and apparatus are provided for developing a complete set of all admissible Type I and Type II fixture designs for a workpiece. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vise is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs.
Processor and method for developing a set of admissible fixture designs for a workpiece
Brost, R.C.; Goldberg, K.Y.; Canny, J.; Wallack, A.S.
1999-01-05
Methods and apparatus are provided for developing a complete set of all admissible Type 1 and Type 2 fixture designs for a workpiece. The fixture processor generates the set of all admissible designs based on geometric access constraints and expected applied forces on the workpiece. For instance, the fixture processor may generate a set of admissible fixture designs for first, second and third locators placed in an array of holes on a fixture plate and a translating clamp attached to the fixture plate for contacting the workpiece. In another instance, a fixture vise is used in which first, second, third and fourth locators are used and first and second fixture jaws are tightened to secure the workpiece. The fixture process also ranks the set of admissible fixture designs according to a predetermined quality metric so that the optimal fixture design for the desired purpose may be identified from the set of all admissible fixture designs. 44 figs.
Friction Stir Weld System for Welding and Weld Repair
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey (Inventor); Romine, Peter L. (Inventor); Oelgoetz, Peter A. (Inventor)
2001-01-01
A friction stir weld system for welding and weld repair has a base foundation unit connected to a hydraulically controlled elevation platform and a hydraulically adjustable pin tool. The base foundation unit may be fixably connected to a horizontal surface or may be connected to a mobile support in order to provide mobility to the friction stir welding system. The elevation platform may be utilized to raise and lower the adjustable pin tool about a particular axis. Additional components which may be necessary for the friction stir welding process include back plate tooling, fixturing and/or a roller mechanism.
Lollo, Pablo C B; Moura, Carolina S; Morato, Priscila N; Amaya-Farfan, Jaime
2013-01-01
Running on a horizontal plane is known to increase the concentration of the stress biomarker heat-shock protein (HSP), but no comparison of the expression of HSP70 has yet been established between the uphill (predominantly concentric) and downhill (predominantly eccentric) muscle contractions exercise. The objective of the study was to investigate the relationships between eccentric and concentric contractions on the HSP70 response of the lung, kidney, gastrocnemius, soleus and heart. Twenty-four male Wistar weanling rats were divided into four groups: non-exercised and three different grades of treadmill exercise groups: horizontal, uphill (+7%) and downhill (-7% of inclination). At the optimal time-point of six hours after the exercise, serum uric acid, creatine kinase (CK) and lactate dehydrogenase (LDH) were determined by standard methods and HSP70 by the Western blot analysis. HSP70 responds differently to different types of running. For kidney, heart, soleus and gastrocnemius, the HSP70 expression increased, 230, 180, 150 and 120% respectively of the reference (horizontal). When the contraction was concentric (uphill) and compared to downhill the increase in response of HSP70 was greater in 80% for kidney, 75% for gastrocnemius, 60% for soleus and 280% for the heart. Uric acid was about 50% higher (0.64 ± 0.03 mg·dL(-1)) in the uphill group as compared to the horizontal or downhill groups. Similarly, the activities of serum CK and LDH were both 100% greater for both the uphill and downhill groups as compared to the horizontal group (2383 ± 253 and 647.00 ± 73 U/L, respectively). The responsiveness of HSP70 appeared to be quite different depending on the type of tissue, suggesting that the impact of exercise was not restricted to the muscles, but extended to the kidney tissue. The uphill exercise increases HSP70 beyond the eccentric type and the horizontal running was a lower HSP70 responsive stimulus. Key PointsExercise can induce increases in HSP70 in the lung, kidney and heart, and in the soleus and gastrocnemius muscles, probably due to systemic alterations such as hypoxia, increase in temperature and the production of free radicals.Predominantly concentric contractions (running uphill), seem to be the most efficient way of increasing the HSP70 concentrations in the different tissues, followed by eccentric contraction (downhill) and lastly the concentric-eccentric cycle (horizontal).The energy demand, already known to influence HSP70, appears not to be the only factor responsible for the response of these proteins, considering that for the kidney and the soleus muscle, downhill running was more efficient in raising the HSP70 response than horizontal running.Future research should explore the mechanisms by which the eccentric, concentric and eccentric-concentric contractions are capable of influencing the responses of the heat shock proteins, opening possibilities for increasing the levels of these proteins in desirable situations, such as to protect against excess free radicals or injuries.
NASA Technical Reports Server (NTRS)
Spiegel, Kirk W.
1990-01-01
Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.
Nelson, Jacob A; Bugbee, Bruce
2014-01-01
Lighting technologies for plant growth are improving rapidly, providing numerous options for supplemental lighting in greenhouses. Here we report the photosynthetic (400-700 nm) photon efficiency and photon distribution pattern of two double-ended HPS fixtures, five mogul-base HPS fixtures, ten LED fixtures, three ceramic metal halide fixtures, and two fluorescent fixtures. The two most efficient LED and the two most efficient double-ended HPS fixtures had nearly identical efficiencies at 1.66 to 1.70 micromoles per joule. These four fixtures represent a dramatic improvement over the 1.02 micromoles per joule efficiency of the mogul-base HPS fixtures that are in common use. The best ceramic metal halide and fluorescent fixtures had efficiencies of 1.46 and 0.95 micromoles per joule, respectively. We also calculated the initial capital cost of fixtures per photon delivered and determined that LED fixtures cost five to ten times more than HPS fixtures. The five-year electric plus fixture cost per mole of photons is thus 2.3 times higher for LED fixtures, due to high capital costs. Compared to electric costs, our analysis indicates that the long-term maintenance costs are small for both technologies. If widely spaced benches are a necessary part of a production system, the unique ability of LED fixtures to efficiently focus photons on specific areas can be used to improve the photon capture by plant canopies. Our analysis demonstrates, however, that the cost per photon delivered is higher in these systems, regardless of fixture category. The lowest lighting system costs are realized when an efficient fixture is coupled with effective canopy photon capture.
Analog Exercise Hardware to Implement a High Intensity Exercise Program During Bed Rest
NASA Technical Reports Server (NTRS)
Loerch, Linda; Newby, Nate; Ploutz-Snyder, Lori
2012-01-01
Background: In order to evaluate novel countermeasure protocols in a space flight analog prior to validation on the International Space Station (ISS), NASA's Human Research Program (HRP) is sponsoring a multi-investigator bedrest campaign that utilizes a combination of commercial and custom-made exercise training hardware to conduct daily resistive and aerobic exercise protocols. This paper will describe these pieces of hardware and how they are used to support current bedrest studies at NASA's Flight Analog Research Unit in Galveston, TX. Discussion: To implement candidate exercise countermeasure studies during extended bed rest studies the following analog hardware are being utilized: Stand alone Zero-Gravity Locomotion Simulator (sZLS) -- a custom built device by NASA, the sZLS allows bedrest subjects to remain supine as they run on a vertically-oriented treadmill (0-15 miles/hour). The treadmill includes a pneumatic subject loading device to provide variable body loading (0-100%) and a harness to keep the subject in contact with the motorized treadmill to provide a ground reaction force at their feet that is quantified by a Kistler Force Plate. Supine Cycle Ergometer -- a commercially available supine cycle ergometer (Lode, Groningen, Netherlands) is used for all cycle ergometer sessions. The ergometer has adjustable shoulder supports and handgrips to help stabilize the subject during exercise. Horizontal Squat Device (HSD) -- a custom built device by Quantum Fitness Corp (Stafford, TX), the HSD allows for squat exercises to be performed while lying in a supine position. The HSD can provide 0 to 600 pounds of force in selectable 5 lb increments, and allows hip translation in both the vertical and horizontal planes. Prone Leg Curl -- a commercially available prone leg curl machine (Cybex International Inc., Medway, MA) is used to complete leg curl exercises. Horizontal Leg Press -- a commercially available horizontal leg press (Quantum Fitness Corporation) is used for leg press and heel raise exercises. Minor modifications were made to the device including adding 200 lbs to the weight stack, raising the frame by 12 inches, making the footplate adjustable, and providing removable handles. Conclusion: A combination of novel and commercial exercise hardware are used to mimic the exercise hardware capabilities aboard the ISS, allowing scientific investigation of new countermeasure protocols in a space flight analog prior to flight validation
Fixture for forming evaporative pattern (EPC) process patterns
Turner, Paul C.; Jordan, Ronald R.; Hansen, Jeffrey S.
1993-01-01
A method of casting metal using evaporative pattern casting process patterns in combination with a fixture for creating and maintaining a desired configuration in flexible patterns. A pattern is constructed and gently bent to the curvature of a suitable fixture. String or thin wire, which burns off during casting, is used to tie the pattern to the fixture. The fixture with pattern is dipped in a commercially available refractory wash to prevent metal adherence and sticking to the fixture. When the refractory wash is dry, the fixture and pattern are placed in a flask, and sand is added and compacted by vibration. The pattern remains in position, restrained by the fixture. Metal that is poured directly into the pattern replaces the pattern exactly but does not contact or weld to the fixture due to the protective refractory layer. When solid, the casting is easily separated from the fixture. The fixture can be cleaned for reuse in conventional casting cleaning equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.
In August 2008 the Pacific Northwest National Laboratory (PNNL) conducted a light emitting diode (LED) residential lighting demonstration project for the U.S. Department of Energy (DOE), Office of Building Technologies, as part of DOE’s Solid State Lighting (SSL) Technology Demonstration Gateway Program. Two lighting technologies, an LED replacement for downlight lamps (bulbs) and an LED undercabinet lighting fixture, were tested in the demonstration which was conducted in two homes built for the 2008 Tour of Homes in Eugene, Oregon. The homes were built by the Lane County Home Builders Association (HBA), and Future B Homes. The Energy Trust of Oregonmore » (ETO) also participated in the demonstration project. The LED downlight product, the LR6, made by Cree LED Lighting Solutions acts as a screw-in replacement for incandescent and halogen bulbs in recessed can downlights. The second product tested is Phillips/Color Kinetics’ eW® Profile Powercore undercabinet fixture designed to mount under kitchen cabinets to illuminate the countertop and backsplash surfaces. Quantitative and qualitative measurements of light performance and electrical power usage were taken at each site before and after initially installed halogen and incandescent lamps were replaced with the LED products. Energy savings and simple paybacks were also calculated and builders who toured the homes were surveyed for their responses to the LED products. The LED downlight product drew 12 Watts of power, cutting energy use by 82% compared to the 65W incandescent lamp and by 84% compared to the 75W halogen lamp. The LED undercabinet fixture drew 10 watts, cutting energy use by 83% to 90% compared to the halogen product, which was tested at two power settings: a low power 60W setting and a high power 105W setting. The LED downlight consistently provided more light than the halogen and incandescent lamps in horizontal measurements at counter height and floor level. It also outperformed in vertical illuminance measurements taken on the walls, indicating better lateral dispersion of the light. The undercabinet fixture’s light output was midway between the low and high power halogen undercabinet fixture light outputs (35.8 foot candle versus 13.4 fc and 53.4 fc) but it produced a more uniform light (max/min ratio of 7.0 versus 10.8). The color correlated temperature (CCT, the blue or yellowness) of the LED light correlated well with the halogen and incandescent lights (2675 K vs 2700 K). The color rendering of the LED downlight also correlated well at 92 CRI compared to 100 CRI for the halogen and incandescent lamps. The LED undercabinet fixture had measures of 2880 K CCT and 71 CRI compared to the 2700 K and 100 CRI scores for the halogen undercabinet fixture. Builders who toured the homes were surveyed; they gave the LED downlight high marks for brightness, said the undercabinet improved shadows and glare and said both products improved overall visibility, home appearance, and home value. Paybacks on the LED downlight ranged from 7.6 years (assuming electricity cost of 11 c/kWh) to 13.5 years (at 5C/kWh). Paybacks on the LED undercabinet fixture in a new home ranged from 4.4 years (11c/kWh electricity) to 7.6 years (5c/kWh) based on product costs of $95 per LED downlight and $140 per LED undercabinet fixture at 3 hrs per day of usage for the downlight and 2 hrs per day for the undercabinet lighting.« less
NASA Astrophysics Data System (ADS)
Allen, Matthew S.; Mayes, Randall L.; Bergman, Elizabeth J.
2010-11-01
Modal substructuring or component mode synthesis (CMS) has been standard practice for many decades in the analytical realm, yet a number of significant difficulties have been encountered when attempting to combine experimentally derived modal models with analytical ones or when predicting the effect of structural modifications using experimental measurements. This work presents a new method that removes the effects of a flexible fixture from an experimentally obtained modal model. It can be viewed as an extension to the approach where rigid masses are removed from a structure. The approach presented here improves the modal basis of the substructure, so that it can be used to more accurately estimate the modal parameters of the built-up system. New types of constraints are also presented, which constrain the modal degrees of freedom of the substructures, avoiding the need to estimate the connection point displacements and rotations. These constraints together with the use of a flexible fixture enable a new approach for joining structures, especially those with statically indeterminate multi-point connections, such as two circular flanges that are joined by many more bolts than required to enforce compatibility if the substructures were rigid. Fixture design is discussed, one objective of which is to achieve a mass-loaded boundary condition that exercises the substructure at the connection point as it is in the built up system. The proposed approach is demonstrated with two examples using experimental measurements from laboratory systems. The first is a simple problem of joining two beams of differing lengths, while the second consists of a three-dimensional structure comprising a circular plate that is bolted at eight locations to a flange on a cylindrical structure. In both cases frequency response functions predicted by the substructuring methods agree well with those of the actual coupled structures over a significant range of frequencies.
NASA Astrophysics Data System (ADS)
Murata, Masaru; Akazawa, Toshiyuki; Yuasa, Toshihiro; Okayama, Miki; Tazaki, Junichi; Hanawa, Takao; Arisue, Makoto; Mizoguchi, Itaru
2012-12-01
A midpalatal implant system has been used as the unmoved anchorage for teeth movement. An 18-year-old male patient presented with reversed occlusion and was diagnosed as malocclusion. A pure titanium fixture (lengths: 4 mm, diameter: 3.3 mm, Orthosystem®, Institute Straumann, Switzerland) was implanted into the palatal bone of the patient as the orthodontic anchorage. The implant anchorage was connected with the upper left and right first molars, and had been used for 3 years. After dynamic treatments, the titanium fixture connected with bone was removed surgically, fixed in formalin solution, and embedded in resin. Specimens were cut along the frontal section of face and the direction of longitudinal axis of the implant, stained, and observed histologically. The titanium fixture was integrated directly with compact bone showing cortical bone-like structure such as lamella and osteon. In addition, to qualitatively characterize the implant-supported human bone, the crystallinity and orientation of hydroxyapatite (HAp) phase were evaluated by the microbeam X-ray diffraction analysis. Preferential alignment of c-axis of HAp crystals was represented by the relative intensity ratio of (0 0 2)-face diffraction peak to (3 1 0)-face one. The values decreased monotonously along the direction of the lateral stress from the site near the implant thread to the distant site in all horizontal lines of the map. These results indicated that the X-ray images for the intensity of c-face in HAp revealed functionally graded distribution of cortical bone quality. The micro-scale measurements of HAp structure could be a useful method for evaluating the mechanical stress distribution in human hard tissues.
Electromyographical Comparison of Four Common Shoulder Exercises in Unstable and Stable Shoulders
Sciascia, Aaron; Kuschinsky, Nina; Nitz, Arthur J.; Mair, Scott D.; Uhl, Tim L.
2012-01-01
This study examines if electromyographic (EMG) amplitude differences exist between patients with shoulder instability and healthy controls performing scaption, prone horizontal abduction, prone external rotation, and push-up plus shoulder rehabilitation exercises. Thirty nine subjects were categorized by a single orthopedic surgeon as having multidirectional instability (n = 10), anterior instability (n = 9), generalized laxity (n = 10), or a healthy shoulder (n = 10). Indwelling and surface electrodes were utilized to measure EMG activity (reported as a % of maximum voluntary isometric contraction (MVIC)) in various shoulder muscles during 4 common shoulder exercises. The exercises studied effectively activated the primary musculature targeted in each exercise equally among all groups. The serratus anterior generated high activity (50–80% MVIC) during a push-up plus, while the infraspinatus and teres major generated moderate-to-high activity (30–80% MVIC) during both the prone horizontal and prone external rotation exercises. Scaption exercise generated moderate activity (20–50% MVIC) in both rotator cuff and scapular musculature. Clinicians should feel confident in prescribing these shoulder-strengthening exercises in patients with shoulder instability as the activation levels are comparable to previous findings regarding EMG amplitudes and should improve the dynamic stabilization capability of both rotator cuff and scapular muscles using exercises designed to address glenohumeral joint instability. PMID:22919499
Effects of Body Position and Immersion on Recovery After Swimming Exercise
ERIC Educational Resources Information Center
McMurray, Robert G.
1969-01-01
Coaches have had differeing opinions concerning the best position for recovery following exercise. Preferred positions range from holding the arms over the head while walking, to lying down. Swimmers are in a unique position in that their exercise is performed in a horizontal plane while immersed in water. (CK)
Test fixture design for boron-aluminum and beryllium test panels
NASA Technical Reports Server (NTRS)
Breaux, C. G.
1973-01-01
A detailed description of the test fixture design and the backup analysis of the fixture assembly and its components are presented. The test fixture is required for the separate testing of two boron-aluminum and two beryllium compression panels. This report is presented in conjunction with a complete set of design drawings on the test fixture system.
Research on the design of fixture for motor vibration test
NASA Astrophysics Data System (ADS)
Shen, W. X.; Ma, W. S.; Zhang, L. W.
2018-03-01
The vibration reliability of the new energy automobile motor plays a very important role in driving safety, so it is very important to test the vibration durability of the motor. In the vibration test process, the fixture is very important, simulated road spectrum signal vibration can be transmitted without distortion to the motor through the fixture, fixture design directly affect the result of vibration endurance test. On the basis of new energy electric vehicle motor concrete structure, Two fixture design and fixture installation schemes for lateral cantilever type and base bearing type are put forward in this article, the selection of material, weighting process, middle alignment process and manufacturing process are summarized.The modal analysis and frequency response calculation of the fixture are carried out in this design, combine with influence caused by fixture height and structure profile on response frequency, the response frequency of each order of the fixture is calculated, then ultimately achieve the purpose of guiding the design.
46 CFR 120.410 - Lighting fixtures.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Each table lamp, desk lamp, floor lamp, or similar equipment must be secured in place so that it cannot... Fixtures,” UL 1571, “Incandescent Lighting Fixtures,” UL 1572, “High Intensity Discharge Lighting Fixtures...
Computer aided fixture design - A case based approach
NASA Astrophysics Data System (ADS)
Tanji, Shekhar; Raiker, Saiesh; Mathew, Arun Tom
2017-11-01
Automated fixture design plays important role in process planning and integration of CAD and CAM. An automated fixture setup design system is developed where when fixturing surfaces and points are described allowing modular fixture components to get automatically select for generating fixture units and placed into position with satisfying assembled conditions. In past, various knowledge based system have been developed to implement CAFD in practice. In this paper, to obtain an acceptable automated machining fixture design, a case-based reasoning method with developed retrieval system is proposed. Visual Basic (VB) programming language is used in integrating with SolidWorks API (Application programming interface) module for better retrieval procedure reducing computational time. These properties are incorporated in numerical simulation to determine the best fit for practical use.
RF Testing Of Microwave Integrated Circuits
NASA Technical Reports Server (NTRS)
Romanofsky, R. R.; Ponchak, G. E.; Shalkhauser, K. A.; Bhasin, K. B.
1988-01-01
Fixtures and techniques are undergoing development. Four test fixtures and two advanced techniques developed in continuing efforts to improve RF characterization of MMIC's. Finline/waveguide test fixture developed to test submodules of 30-GHz monolithic receiver. Universal commercially-manufactured coaxial test fixture modified to enable characterization of various microwave solid-state devices in frequency range of 26.5 to 40 GHz. Probe/waveguide fixture is compact, simple, and designed for non destructive testing of large number of MMIC's. Nondestructive-testing fixture includes cosine-tapered ridge, to match impedance wavequide to microstrip. Advanced technique is microwave-wafer probing. Second advanced technique is electro-optical sampling.
Nishioka, Renato Sussumu; Rodrigues, Vinicius Anéas; De Santis, Leandro Ruivo; Nishioka, Gabriela Nogueira De Melo; Santos, Vivian Mayumi Miyazaki; Souza, Francisley Ávila
2016-02-01
To quantify microstrain development during axial loading using strain gauge analysis for short implants, varying the type of fixture-abutment joint and thread design. An internal hexagon implant (4 × 8 mm) and a plateau design implant (4 × 8 mm) were embedded on the center of 10 polyurethane blocks with dimensions of 190 × 30 × 12 mm. The respective abutments were screwed onto the implants. Four strain gauges (SGs) were bonded onto the surface of each block, and 4 vertical SGs were bonded onto the side of each block. Axial load of 30 kgf was applied for 10 seconds in the center of each implant. The data were analyzed statistically by analysis of variance for repeated measures and Tukey test (P < 0.05). The interaction between implant and region factors have been statistically significant (P = 0.0259). Tukey test revealed a difference on plateau's horizontal region. The cervical region presented higher microstrain values, when compared with the medium and apical regions of the implants. Within the purpose of the study, the type of fixture-abutment joint is a relevant factor to affect the amount of stress/strain in bone simulation. The microstrain development was concentrated on the cervical region of the implant.
Development of sacrificial support fixture using deflection analysis
NASA Astrophysics Data System (ADS)
Ramteke, Ashwini M.; Ashtankar, Kishor M.
2018-04-01
Sacrificial support fixtures are the structures used to hold the part during machining while rotating the part about the fourth axis of CNC machining. In Four axis CNC machining part is held in a indexer which is rotated about the fourth axis of rotation. So using traditional fixturing devices to hold the part during machining such as jigs, v blocks and clamping plates needs a several set ups, manufacturing time which increase the cost associated with it. Since the part is rotated about the axis of rotation in four axis CNC machining so using traditional fixturing devices to hold the part while machining we need to reorient the fixture each time for particular orientation of part about the axis of rotation. So our proposed methodology of fixture design eliminates the cost associate with the complicated fixture design for customized parts which in turn reduces the time of manufacturing of the fixtures. But while designing the layout of the fixtures it is found out that the machining the part using four axis CNC machining the accurate machining of the part is directly proportional to the deflection produced in a part. So to machine an accurate part the deflection produced in a part should be minimum. We assume that the deflection produced in a part is a result of the deflection produced in a sacrificial support fixture while machining. So this paper provides the study of the deflection checking in a part machined using sacrificial support fixture by using FEA analysis.
46 CFR 111.75-20 - Lighting fixtures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Lighting Circuits and Protection § 111.75-20 Lighting fixtures. (a) The construction of each... connection box for a circuit other than the branch circuit supplying the fixture. (d) Lighting fixtures must...
Optical fiber cable chemical stripping fixture
NASA Technical Reports Server (NTRS)
Kolasinski, John R. (Inventor); Coleman, Alexander M. (Inventor)
1995-01-01
An elongated fixture handle member is connected to a fixture body member with both members having interconnecting longitudinal central axial bores for the passage of an optical cable therethrough. The axial bore of the fixture body member, however, terminates in a shoulder stop for the outer end of a jacket of the optical cable covering both an optical fiber and a coating therefor, with an axial bore of reduced diameter continuing from the shoulder stop forward for a predetermined desired length to the outer end of the fixture body member. A subsequent insertion of the fixture body member including the above optical fiber elements into a chemical stripping solution results in a softening of the exposed external coating thereat which permits easy removal thereof from the optical fiber while leaving a desired length coated fiber intact within the fixture body member.
Evaluation of supraspinatus strengthening exercises based on fiber bundle architectural changes.
Sachdeva, R; Farthing, J P; Kim, S Y
2017-07-01
Supraspinatus strengthening is an integral part of rehabilitation programs. However, there is disparity regarding the best exercise. Thus, we investigated the effects of supraspinatus strengthening exercises on muscle fiber bundle architecture using real-time ultrasound. Participants were randomized into full-can (FC; n = 12), empty-can (EC; n = 11,) and prone horizontal abduction (PHA; n = 11) groups and performed three sessions/week for 8 weeks. Each session involved four sets of exercise for weeks 1-4 and six sets for weeks 5-8 with eight repetitions/set. Images of supraspinatus were captured in 0° (relaxed) and 60° (contracted) glenohumeral abduction. Fiber bundle length (FBL), pennation angle, and muscle thickness were measured at beginning, mid, and end of training. Maximum isometric abduction strength was measured in full-can, empty-can, and prone horizontal abduction positions using a hand-held dynamometer. FBL decreased after 4 weeks in FC [relaxed: Δ = -0.54 cm, P = 0.001, d = 0.92; contracted: Δ = -0.27 cm, P = 0.008, d = 0.27] and EC [relaxed: Δ = -0.59 cm, P = 0.008, d = 0.86; contracted: Δ = -0.36 cm, P = 0.013, d = 0.59], but not in PHA [relaxed: Δ = -0.11, P = 0.121, d = 0.31; contracted: Δ = -0.06 cm, P = 0.486, d = 0.13]. Strength increased significantly from week 4-8 only in PHA (Δ = +0.96 kg, P = 0.004, d = 0.47) when tested in prone horizontal abduction position. Maintenance of FBL with increased strength indicates prone horizontal abduction may be a better exercise to strengthen supraspinatus. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mujika, Iñigo; Burke, Louise M
2010-01-01
Team sports are based on intermittent high-intensity activity patterns, but the exact characteristics vary between and within codes, and from one game to the next. Despite the challenge of predicting exact game demands, performance in team sports is often dependent on nutritional factors. Chronic issues include achieving ideal levels of muscle mass and body fat, and supporting the nutrient needs of the training program. Acute issues, both for training and in games, include strategies that allow the player to be well fuelled and hydrated over the duration of exercise. Each player should develop a plan of consuming fluid and carbohydrate according to the needs of their activity patterns, within the breaks that are provided in their sport. In seasonal fixtures, competition varies from a weekly game in some codes to 2-3 games over a weekend road trip in others, and a tournament fixture usually involves 1-3 days between matches. Recovery between events is a major priority, involving rehydration, refuelling and repair/adaptation activities. Some sports supplements may be of value to the team athlete. Sports drinks, gels and liquid meals may be valuable in allowing nutritional goals to be met, while caffeine, creatine and buffering agents may directly enhance performance. Copyright © 2011 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anex, R.P.; Lund, J.R.; Chang, D.P.Y.
1998-06-01
The purpose of this study is to update the methods for estimating emissions from the industrial coatings subcategory of wood furniture and fixtures. The wood furniture and fixture industry encompasses the manufacture of diverse products including cabinets, office furniture, store fixtures, and residential furniture. Specific objectives of this work are to: (1) estimate the amount of coating used in the industrial surface coating of wood furniture and fixtures; (2) develop emissions factors for each coating application category; (3) estimate variability of both coating use and emission factors; and (4) specify a source of information and method to revise and updatemore » the industrial coating of wood furniture and fixtures emission inventory.« less
Alignment Fixtures For Vacuum-Plasma-Spray Gun
NASA Technical Reports Server (NTRS)
Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.
1993-01-01
Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.
Shear-Panel Test Fixture Eliminates Corner Stresses
NASA Technical Reports Server (NTRS)
Kiss, J. J.; Farley, G. L.; Baker, D. J.
1984-01-01
New design eliminates corner stresses while maintaining uniform stress across panel. Shear panel test fixture includes eight frames and eight corner pins. Fixture assembled in two halves with shear panel sandwiched in between. Results generated from this fixture will result in good data base for design of efficient aircraft structures and other applications.
EIGHTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
2013-09-03
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23more » GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 61 - 85 months, which is still bounding to O-ring temperatures during storage in KArea Complex (KAC). Based on expectations that the fixtures aging at 200 ºF will remain leaktight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 41 - 45 months. Aging and periodic leak testing will continue for the remaining PCV fixtures.« less
Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants
Jain, Anoop; K, Cauvery; Kumar, Pawan; Havale, Raghavendra
2014-01-01
An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques. PMID:24959520
Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants.
Mahoorkar, Sudhindra; Jain, Anoop; K, Cauvery; Kumar, Pawan; Havale, Raghavendra
2014-04-01
An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.
75 FR 41840 - Commission Information Collection Activities (FERC-919); Comment Request; Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-19
... vertical market power. To demonstrate lack of horizontal market power, two indicative market power screens... basis. These screens examine whether a seller has the ability to exercise horizontal market power... referenced. To demonstrate a lack of vertical market power, to the extent that a public utility with market...
1997-07-18
Jet Propulsion Laboratory (JPL) workers David Rice, at left, and Johnny Melendez rotate a radioisotope thermoelectric generator (RTG) to the horizontal position on a lift fixture in the Payload Hazardous Servicing Facility. The RTG is one of three generators which will provide electrical power for the Cassini spacecraft mission to the Saturnian system. The RTGs will be installed on the powered-up spacecraft for mechanical and electrical verification testing. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate far from the Sun where solar power systems are not feasible. The Cassini mission is scheduled for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed for NASA by JPL
[Core muscle chains activation during core exercises determined by EMG-a systematic review].
Rogan, Slavko; Riesen, Jan; Taeymans, Jan
2014-10-15
Good core muscles strength is essential for daily life and sports activities. However, the mechanism how core muscles may be effectively triggered by exercises is not yet precisely described in the literature. The aim of this systematic review was to evaluate the rate of activation as measured by electromyography of the ventral, lateral and dorsal core muscle chains during core (trunk) muscle exercises. A total of 16 studies were included. Exercises with a vertical starting position, such as the deadlift or squat activated significantly more core muscles than exercises in the horizontal initial position.
Handheld Micromanipulation with Vision-Based Virtual Fixtures
Becker, Brian C.; MacLachlan, Robert A.; Hager, Gregory D.; Riviere, Cameron N.
2011-01-01
Precise movement during micromanipulation becomes difficult in submillimeter workspaces, largely due to the destabilizing influence of tremor. Robotic aid combined with filtering techniques that suppress tremor frequency bands increases performance; however, if knowledge of the operator's goals is available, virtual fixtures have been shown to greatly improve micromanipulator precision. In this paper, we derive a control law for position-based virtual fixtures within the framework of an active handheld micromanipulator, where the fixtures are generated in real-time from microscope video. Additionally, we develop motion scaling behavior centered on virtual fixtures as a simple and direct extension to our formulation. We demonstrate that hard and soft (motion-scaled) virtual fixtures outperform state-of-the-art tremor cancellation performance on a set of artificial but medically relevant tasks: holding, move-and-hold, curve tracing, and volume restriction. PMID:23275860
Culture and Consumer Behavior: The Role of Horizontal and Vertical Cultural Factors
Shavitt, Sharon; Cho, Hyewon
2016-01-01
We examine the influence of culture on consumer behavior with a particular focus on horizontal and vertical individualism and collectivism. Cultures vary in their propensity to emphasize hierarchy, a distinction captured by examining horizontal/vertical cultural orientations or contexts. These cultural factors pattern personal values and goals, power concepts, and normative expectations applied to the exercise of power. We review implications for how consumers respond to brands in the marketplace, service providers, and each others' needs. PMID:28083559
Culture and Consumer Behavior: The Role of Horizontal and Vertical Cultural Factors.
Shavitt, Sharon; Cho, Hyewon
2016-04-01
We examine the influence of culture on consumer behavior with a particular focus on horizontal and vertical individualism and collectivism. Cultures vary in their propensity to emphasize hierarchy, a distinction captured by examining horizontal/vertical cultural orientations or contexts. These cultural factors pattern personal values and goals, power concepts, and normative expectations applied to the exercise of power. We review implications for how consumers respond to brands in the marketplace, service providers, and each others' needs.
Improvement of Long-Jump Performance During Competition Using a Plyometric Exercise.
Bogdanis, Gregory C; Tsoukos, Athanasios; Veligekas, Panagiotis
2017-02-01
To examine the acute effects of a conditioning plyometric exercise on long-jump performance during a simulated long-jump competition. Eight national-level track and field decathletes performed 6 long-jump attempts with a full approach run separated by 10-min recoveries. In the experimental condition subjects performed 3 rebound vertical jumps with maximal effort 3 min before the last 5 attempts, while the 1st attempt served as baseline. In the control condition the participants performed 6 long jumps without executing the conditioning exercise. Compared with baseline, long-jump performance progressively increased only in the experimental condition, from 3.0%, or 17.5 cm, in the 3rd attempt (P = .046, d = 0.56), to 4.8%, or 28.2 cm, in the 6th attempt (P = .0001, d = 0.84). The improvement in long-jump performance was due to a gradual increase in vertical takeoff velocity from the 3rd (by 8.7%, P = .0001, d = 1.82) to the 6th jump (by 17.7%, P = .0001, d = 4.38). Horizontal-approach velocity, takeoff duration, and horizontal velocity at takeoff were similar at all long-jump attempts in both conditions (P = .80, P = .36, and P = .15, respectively). Long-jump performance progressively improved during a simulated competition when a plyometric conditioning exercise was executed 3 min before each attempt. This improvement was due to a progressive increase in vertical velocity of takeoff, while there was no effect on the horizontal velocity.
Vision-Based Control of a Handheld Surgical Micromanipulator with Virtual Fixtures
Becker, Brian C.; MacLachlan, Robert A.; Lobes, Louis A.; Hager, Gregory D.; Riviere, Cameron N.
2012-01-01
Performing micromanipulation and delicate operations in submillimeter workspaces is difficult because of destabilizing tremor and imprecise targeting. Accurate micromanipulation is especially important for microsurgical procedures, such as vitreoretinal surgery, to maximize successful outcomes and minimize collateral damage. Robotic aid combined with filtering techniques that suppress tremor frequency bands increases performance; however, if knowledge of the operator’s goals is available, virtual fixtures have been shown to further improve performance. In this paper, we derive a virtual fixture framework for active handheld micromanipulators that is based on high-bandwidth position measurements rather than forces applied to a robot handle. For applicability in surgical environments, the fixtures are generated in real-time from microscope video during the procedure. Additionally, we develop motion scaling behavior around virtual fixtures as a simple and direct extension to the proposed framework. We demonstrate that virtual fixtures significantly outperform tremor cancellation algorithms on a set of synthetic tracing tasks (p < 0.05). In more medically relevant experiments of vein tracing and membrane peeling in eye phantoms, virtual fixtures can significantly reduce both positioning error and forces applied to tissue (p < 0.05). PMID:24639624
Virtual fixtures as tools to enhance operator performance in telepresence environments
NASA Astrophysics Data System (ADS)
Rosenberg, Louis B.
1993-12-01
This paper introduces the notion of virtual fixtures for use in telepresence systems and presents an empirical study which demonstrates that such virtual fixtures can greatly enhance operator performance within remote environments. Just as tools and fixtures in the real world can enhance human performance by guiding manual operations, providing localizing references, and reducing the mental processing required to perform a task, virtual fixtures are computer generated percepts overlaid on top of the reflection of a remote workspace which can provide similar benefits. Like a ruler guiding a pencil in a real manipulation task, a virtual fixture overlaid on top of a remote workspace can act to reduce the mental processing required to perform a task, limit the workload of certain sensory modalities, and most of all allow precision and performance to exceed natural human abilities. Because such perceptual overlays are virtual constructions they can be diverse in modality, abstract in form, and custom tailored to individual task or user needs. This study investigates the potential of virtual fixtures by implementing simple combinations of haptic and auditory sensations as perceptual overlays during a standardized telemanipulation task.
Fuel utilization during exercise after 7 days of bed rest
NASA Technical Reports Server (NTRS)
Barrows, Linda H.; Harris, Bernard A.; Moore, Alan D.; Siconolfi, Steven F.
1992-01-01
Energy yield from carbohydrate, fat, and protein during physical activity is partially dependent on an individual's fitness level. Prolonged exposure to microgravity causes musculoskeletal and cardiovascular deconditioning; these adaptations may alter fuel utilization during space flight. Carbohydrate and fat metabolism during exercise were analyzed before and after 7 days of horizontal bed rest.
NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2014-08-06
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determinemore » if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.« less
18. FIRST FLOOR, DETAIL OF CEILING AND LIGHT FIXTURE (AS ...
18. FIRST FLOOR, DETAIL OF CEILING AND LIGHT FIXTURE (AS SEEN IN SC-135-18), MADE OF BRASS, ORIGINALLY GAS, CONVERTED TO ELECTRICITY, FIXTURE LIT - Market Hall, 188 Meeting Street, Charleston, Charleston County, SC
Dissipation factor as a predictor of anodic coating performance
Panitz, Janda K. G.
1995-01-01
A dissipation factor measurement is used to predict as-anodized fixture performance prior to actual use of the fixture in an etching environment. A dissipation factor measurement of the anodic coating determines its dielectric characteristics and correlates to the performance of the anodic coating in actual use. The ability to predict the performance of the fixture and its anodized coating permits the fixture to be repaired or replaced prior to complete failure.
Controlled shear/tension fixture
Hsueh, Chun-Hway [Knoxville, TN; Liu, Chain-tsuan [Knoxville, TN; George, Easo P [Knoxville, TN
2012-07-24
A test fixture for simultaneously testing two material test samples is provided. The fixture provides substantially equal shear and tensile stresses in each test specimens. By gradually applying a load force to the fixture only one of the two specimens fractures. Upon fracture of the one specimen, the fixture and the load train lose contact and the second specimen is preserved in a state of upset just prior to fracture. Particular advantages of the fixture are (1) to control the tensile to shear load on the specimen for understanding the effect of these stresses on the deformation behavior of advanced materials, (2) to control the location of fracture for accessing localized material properties including the variation of the mechanical properties and residual stresses across the thickness of advanced materials, (3) to yield a fractured specimen for strength measurement and an unfractured specimen for examining the microstructure just prior to fracture.
Development of an improved GTA (gas tungsten arc) weld temperature monitor fixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollar, D.L.
1990-05-01
An initial design weld temperature control fixture was implemented into final closure of an electronic assembly in November 1986. Use of this fixture indicated several areas that could be improved. Review of these areas with the process engineer and the weld operator provided the ideas to be incorporated into the new design Phase 2 fixture. Some primary areas of change and improvement included fixture mobility to provide better accessibility to the weld joint area, automatic timed blow cooling of the weld joint, and a feature to assure proper thermocouple placement. The resulting Phase 2 fixture design provided all of themore » essential weld temperature monitoring features in addition to several significant improvements. Technology developed during this project will pave the way to similar process monitoring of other manual gas tungsten arc (GTA) welding applications. 9 figs.« less
Investigation of thermal management technique in blue LED airport taxiway fixtures
NASA Astrophysics Data System (ADS)
Gu, Yimin; Baker, Alex; Narendran, Nadarajah
2007-09-01
On airport runways, blue light fixtures denote taxiways between the runway and the airport terminal. Blue optics transmit mostly short-wavelength radiation, which makes traditional incandescent lamps a poor choice of light source; the resulting fixture efficiency could be less than one percent. LEDs are replacing incandescent lamps in this application. But unlike incandescent sources, LEDs do not radiate enough heat to melt ice and snow from the fixture optics. To meet Federal Aviation Administration (FAA) regulations for weatherability, some LED-based fixtures incorporate electric heaters that, when switched on, nearly negate the energy-savings benefit of converting to LED sources. In this study, we explored methods for conduction and convection of LED junction heat to taxiway fixture optics for the purpose of minimizing snow and ice buildup. A more efficient LED-based system compared to incandescent that would require no additional heaters was demonstrated.
Additive Manufacturing of Advanced High Temperature Masking Fixtures for EBPVD TBC Coating
DOE Office of Scientific and Technical Information (OSTI.GOV)
List, III, Frederick Alyious; Feuerstein, Albert; Dehoff, Ryan
2016-03-30
The purpose of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Praxair Surface Technologies, Inc. (PST) and Oak Ridge National Laboratory (ORNL) was to develop an additive manufacturing process to fabricate next generation high temperature masking fixtures for coating of turbine airfoils with ceramic Thermal Barrier Coatings (TBC) by the Electron Beam Physical Vapor Deposition (EBPVD) process. Typical masking fixtures are sophisticated designs and require complex part manipulation in order to achieve the desired coating distribution. Fixtures are typically fabricated from high temperature nickel (Ni) based superalloys. The fixtures are fabricated from conventional processes by welding of thin sheetmore » material into a complex geometry, to decrease the weight load for the manipulator and to reduce the thermal mass of the fixture. Recent attempts have been made in order to fabricate the fixtures through casting, but thin walled sections are difficult to cast and have high scrap rates. This project focused on understanding the potential for fabricating high temperature Ni based superalloy fixtures through additive manufacturing. Two different deposition processes; electron beam melting (EBM) and laser powder bed fusion were evaluated to determine the ideal processing route of these materials. Two different high temperature materials were evaluated. The high temperature materials evaluated were Inconel 718 and another Ni base alloy, designated throughout the remainder of this document as Alloy X, as the alloy composition is sensitive. Inconel 718 is a more widely utilized material for additive manufacturing although it is not currently the material utilized for current fixtures. Alloy X is the alloy currently used for the fixtures, but is not a commercially available alloy for additive manufacturing. Praxair determined it was possible to build the fixture using laser powder bed technology from Inconel 718. ORNL fabricated the fixture geometry using the EBM technology in order to compare deposition features such as surface roughness, geometric accuracy, deposition rate, surface and subsurface porosity, and material quality. It was determined that the laser powder bed technology was ideal for the geometry and requirements of the fixture set by Praxair, and Praxair moved forward with the purchase of a laser powder bed system. The subsequent portion of the project focused on determining the ideal processing parameters for alloy X for the laser powder bed system using ORNL’s Renishaw laser powder bed system. Praxair supplied gas atomized powders of alloy X material with properties specified by ORNL. ORNL printed text cube arrays in order to determine the ideal combination of laser powder and laser travel speed in order to maximize material density, improve surface quality, and maintain geometric accuracy. Additional powder supplied by Praxair was used to fabricate a full-scale fixture component.« less
Graphite Composite Panel Polishing Fixture
NASA Technical Reports Server (NTRS)
Hagopian, John; Strojny, Carl; Budinoff, Jason
2011-01-01
The use of high-strength, lightweight composites for the fixture is the novel feature of this innovation. The main advantage is the light weight and high stiffness-to-mass ratio relative to aluminum. Meter-class optics require support during the grinding/polishing process with large tools. The use of aluminum as a polishing fixture is standard, with pitch providing a compliant layer to allow support without deformation. Unfortunately, with meter-scale optics, a meter-scale fixture weighs over 120 lb (.55 kg) and may distort the optics being fabricated by loading the mirror and/or tool used in fabrication. The use of composite structures that are lightweight yet stiff allows standard techniques to be used while providing for a decrease in fixture weight by almost 70 percent. Mounts classically used to support large mirrors during fabrication are especially heavy and difficult to handle. The mount must be especially stiff to avoid deformation during the optical fabrication process, where a very large and heavy lap often can distort the mount and optic being fabricated. If the optic is placed on top of the lapping tool, the weight of the optic and the fixture can distort the lap. Fixtures to support the mirror during fabrication are often very large plates of aluminum, often 2 in. (.5 cm) or more in thickness and weight upwards of 150 lb (68 kg). With the addition of a backing material such as pitch and the mirror itself, the assembly can often weigh over 250 lb (.113 kg) for a meter-class optic. This innovation is the use of a lightweight graphite panel with an aluminum honeycomb core for use as the polishing fixture. These materials have been used in the aerospace industry as structural members due to their light weight and high stiffness. The grinding polishing fixture consists of the graphite composite panel, fittings, and fixtures to allow interface to the polishing machine, and introduction of pitch buttons to support the optic under fabrication. In its operation, the grinding polishing fixture acts as a reaction structure to the polishing tool. It must be stiff enough to avoid imparting a distorted shape to the optic under fabrication and light enough to avoid self-deflection. The fixture must also withstand significant tangential loads from the polishing machine during operations.
Aluminum Manganese Molten Salt Plating
2006-06-01
fixture from overhead crane hook and locate fixture over the closed acid tank. 2. Ventilation a. Set valve positions as follows (same as Section I.4.a...overhead crane hook and position the fixture over the closed acid tank. (Will need to remove the top stainless steel rod, clasp the remaining rod with the... crane hook , replace the rod that was removed by threading it through the crane hook , and finally lift the fixture off its storage hook . The cotter
Ferreira, Diogo V; Gentil, Paulo; Ferreira-Junior, João B; Soares, Saulo R S; Brown, Lee E; Bottaro, Martim
2017-10-01
To evaluate the time course of peak torque and total work recovery after a resistance training session involving the bench press exercise. Repeated measures with a within subject design. Twenty-six resistance-trained men (age: 23.7±3.7years; height: 176.0±5.7cm; mass: 79.65±7.61kg) performed one session involving eight sets of the bench press exercise performed to momentary muscle failure with 2-min rest between sets. Shoulder horizontal adductors peak torque (PT), total work (TW), delayed onset muscle soreness (DOMS) and subjective physical fitness were measured pre, immediately post, 24, 48, 72 and 96h following exercise. The exercise protocol resulted in significant pectoralis major DOMS that lasted for 72h. Immediately after exercise, the reduction in shoulder horizontal adductors TW (25%) was greater than PT (17%). TW, as a percentage of baseline values, was also less than PT at 24, 48 and 96h after exercise. Additionally, PT returned to baseline at 96h, while TW did not. Resistance trained men presented dissimilar PT and TW recovery following free weight bench press exercise. This indicates that recovery of maximal voluntary contraction does not reflect the capability to perform multiple contractions. Strength and conditioning professionals should be cautious when evaluating muscle recovery by peak torque, since it can lead to the repetition of a training session sooner than recommended. Copyright © 2017. Published by Elsevier Inc.
Fixture tests bellows reliability through repetitive pressure/temperature cycling
NASA Technical Reports Server (NTRS)
Levinson, C.
1967-01-01
Fixture explores the reliability of bellows used in precision in inertial systems. The fixture establishes the ability of the bellows to withstand repetitive over-stress pressure cycling at elevated temperatures. It is applicable in quality control and reliability programs.
Self-aligning fixture used in lathe chuck jaw refacing
NASA Technical Reports Server (NTRS)
Linn, C. C.
1965-01-01
Self-aligning tool positions and rigidly holds lathe chuck jaws for refacing and truing of the clamping surface. The jaws clamp the fixture in the manner of clamping a workpiece. The fixture can be modified to accommodate four-jawed checks.
Combined Loads Test Fixture for Thermal-Structural Testing Aerospace Vehicle Panel Concepts
NASA Technical Reports Server (NTRS)
Fields, Roger A.; Richards, W. Lance; DeAngelis, Michael V.
2004-01-01
A structural test requirement of the National Aero-Space Plane (NASP) program has resulted in the design, fabrication, and implementation of a combined loads test fixture. Principal requirements for the fixture are testing a 4- by 4-ft hat-stiffened panel with combined axial (either tension or compression) and shear load at temperatures ranging from room temperature to 915 F, keeping the test panel stresses caused by the mechanical loads uniform, and thermal stresses caused by non-uniform panel temperatures minimized. The panel represents the side fuselage skin of an experimental aerospace vehicle, and was produced for the NASP program. A comprehensive mechanical loads test program using the new test fixture has been conducted on this panel from room temperature to 500 F. Measured data have been compared with finite-element analyses predictions, verifying that uniform load distributions were achieved by the fixture. The overall correlation of test data with analysis is excellent. The panel stress distributions and temperature distributions are very uniform and fulfill program requirements. This report provides details of an analytical and experimental validation of the combined loads test fixture. Because of its simple design, this unique test fixture can accommodate panels from a variety of aerospace vehicle designs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruland, Robert
The Visible-Infrared SASE Amplifier (VISA) undulator consists of four 99cm long segments. Each undulator segment is set up on a pulsed-wire bench, to characterize the magnetic properties and to locate the magnetic axis of the FODO array. Subsequently, the location of the magnetic axis, as defined by the wire, is referenced to tooling balls on each magnet segment by means of a straightness interferometer. After installation in the vacuum chamber, the four magnet segments are aligned with respect to themselves and globally to the beam line reference laser. A specially designed alignment fixture is used to mount one straightness interferometermore » each in the horizontal and vertical plane of the beam. The goal of these procedures is to keep the combined rms trajectory error, due to magnetic and alignment errors, to 50{micro}m.« less
Handling 20 tons of honeycomb mirror with a very gentle touch
NASA Astrophysics Data System (ADS)
Davison, Warren B.; Williams, Joseph T.; Hill, John M.
1998-08-01
The 6.5 meter and 8.4 meter mirrors being produced at Steward Observatory have to be lifted, turned, ground, polished, shipped and installed without exceeding 0.7 MPa (100 psi) stress in the glass. Many pieces of specialized equipment and some innovations are required to do this on a tight budget. We have developed lifting fixtures that are either glued on or held by vacuum. We have also designed turning rings that fill our lab, and transportation boxes to hold the mirror horizontal, vertical or in a ship. The sheer size and mass of the mirrors and equipment, plus the very stringent constraints makes the solutions interesting. This may not be the part of telescope design and construction that attracts the most attention, unless...
SEVENTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2012-08-30
A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23more » GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 54-72 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 ºF will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 30 - 36 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51 – 96%. This is greater than seen to date for any packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350 – 400 ºF). However, at 300 ºF, the room temperature leak test failures to date experienced longer aging times than predicted by the CSRbased model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 ºF will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining PCV O-ring fixtures.« less
Multisurface fixture permits easy grinding of tool bit angles
NASA Technical Reports Server (NTRS)
Jones, C. R.
1966-01-01
Multisurface fixture with a tool holder permits accurate grinding and finishing of right and left hand single point threading tools. All angles are ground by changing the fixture position to rest at various references angles without removing the tool from the holder.
Fixture For Drilling And Tapping A Curved Workpiece
NASA Technical Reports Server (NTRS)
Espinosa, P. S.; Lockyer, R. T.
1992-01-01
Simple fixture guides drilling and tapping of holes in prescribed locations and orientations on workpiece having curved surface. Tool conceived for use in reworking complexly curved helicopter blades made of composite materials. Fixture is block of rigid foam with epoxy filler, custom-fitted to surface contour, containing bushings and sleeves at drilling and tapping sites. Bushings changed, so taps and drills of various sizes accommodated. In use, fixture secured to surface by hold-down bolts extending through sleeves and into threads in substrate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-09-01
The furniture and fixtures industry encompasses companies that manufacture household, office, store, public building, and restaurant furniture and fixtures. The second section provides background information on the size, geographic distribution, employment, production, sales, and economic condition of the Wood Furniture and Fixtures industry. The type of facilities described within the document are also described in terms of their Standard Industrial Classification (SIC) codes. Additionally, this section contains a list of the largest companies in terms of sales.
SIXTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W.
2011-08-31
A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for seven years at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues formore » 33 GLT O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 F and higher temperatures, and in 7 fixtures aging at 300 F. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 41-60 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200 F will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging within the past year at an intermediate temperature of 270 F, with hopes that they may leak before the 200 F fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200-300 F for up to 26 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-96%. This is greater than seen to date for packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350-400 F). However, at 300 F, the room temperature leak test failures to date experienced longer aging times than predicted by the CSR-based model. This suggests that extrapolations of the CSR model predictions to temperatures below 300 F will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.« less
Space assembly fixtures and aids
NASA Technical Reports Server (NTRS)
Bloom, K. A.; Lillenas, A. N.
1980-01-01
Concepts and requirements for assembly fixtures and aids necessary for the assembly and maintenance of spare platforms were studied. Emphasis was placed on erectable and deployable type structures with the shuttle orbiter as the assembly base. Both single and multiple orbiter flight cases for the platform assembly were considered. Applicable space platform assembly studies were reviewed to provide a data base for establishing the assembly fixture and aids design requirements, assembly constraints, and the development of representative design concepts. Conclusions indicated that fixture requirements will vary with platform size. Larger platforms will require translation relative to the orbiter RMS working volume. The installation of platform payloads and subsystems (e.g., utility distribution) must also be considered in the specification of assembly fixtures and aids.
Fixture for aligning motor assembly
Shervington, Roger M.; Vaghani, Vallabh V.; Vanek, Laurence D.; Christensen, Scott A.
2009-12-08
An alignment fixture includes a rotor fixture, a stator fixture and a sensor system which measures a rotational displacement therebetween. The fixture precisely measures rotation of a generator stator assembly away from a NULL position referenced by a unique reference spline on the rotor shaft. By providing an adjustable location of the stator assembly within the housing, the magnetic axes within each generator shall be aligned to a predetermined and controlled tolerance between the generator interface mounting pin and the reference spline on the rotor shaft. Once magnetically aligned, each generator is essentially a line replaceable unit which may be readily mounted to any input of a multi-generator gearbox assembly with the assurance that the magnetic alignment will be within a predetermined tolerance.
Squat Ground Reaction Force on a Horizontal Squat Device, Free Weights, and Smith Machine
NASA Technical Reports Server (NTRS)
Scott-Pandorf, Melissa M.; Newby, Nathaniel J.; Caldwell, Erin; DeWitt, John K.; Peters, Brian T.
2010-01-01
Bed rest is an analog to spaceflight and advancement of exercise countermeasures is dependent on the development of exercise equipment that closely mimic actual upright exercise. The Horizontal Squat Device (HSD) was developed to allow a supine exerciser to perform squats that mimic upright squat exercise. PURPOSE: To compare vertical ground reaction force (GRFv) on the HSD with Free Weight (FW) or Smith Machine (SM) during squat exercise. METHODS: Subjects (3F, 3M) performed sets of squat exercise with increasing loads up to 1-repetition (rep) maximum. GRF data were collected and compared with previous GRF data for squat exercise performed with FW & SM. Loads on the HSD were adjusted to magnitudes comparable with FW & SM by subtracting the subject s body weight (BW). Peak GRFv for 45-, 55-, 64-, & 73-kg loads above BW were calculated. Percent (%) difference between HSD and the two upright conditions were computed. Effect size was calculated for the 45-kg load. RESULTS: Most subjects were unable to lift >45 kg on the HSD; however, 1 subject completed all loads. Anecdotal evidence suggested that most subjects shoulders or back failed before their legs. The mean % difference are shown. In the 45-kg condition, effect sizes were 0.37 & 0.83 (p>0.05) for HSD vs. FW and HSD vs. SM, respectively, indicating no differences between exercise modes. CONCLUSION: When BW was added to the target load, results indicated that vertical forces were similar to those in FW and SM exercise. The exercise prescription for the HSD should include a total external resistance equivalent to goal load plus subject BW. The HSD may be used as an analog to upright exercise in bed rest studies, but because most subjects were unable to lift >45 kg, it may be necessary to prescribe higher reps and lower loads to better target the leg musculature
24 CFR 3280.807 - Fixtures and appliances.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Fixtures and appliances. 3280.807... Fixtures and appliances. (a) Electrical materials, devices, appliances, fittings, and other equipment... fasten appliances when the manufactured home is in transit. (See § 3280.809.) (b) Specifically listed...
Fixtures Hold Nuts During Tightening Of Bolts
NASA Technical Reports Server (NTRS)
Gyekenyesi, John Z.
1993-01-01
Two fixtures designed for use on cross-head of tensile testing machine simplify adjustments of crosshead to accommodate specimens of various lengths. Two cagelike fixtures hold pairs of nuts, preventing nuts from turning while bolts are tightened. Enable one person acting alone to tighten bolts.
Cable clamp bolt fixture facilitates assembly in close quarters
NASA Technical Reports Server (NTRS)
Sunderland, G. H.
1967-01-01
Cable clamp bolt holding fixture facilitates forming of electrical cable runs in limited equipment space. The fixture engages the threads of the short clamp bolt through the clamp and maintains tension against clamp tendency to open while the operator installs the nut without difficulty.
46 CFR 129.410 - Lighting fixtures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL... electrical system operating at more than 50 volts must comply with UL 595, “Marine Type Electric Lighting... comply with UL 57, “Electric Lighting Fixtures,” UL 1570, “Fluorescent Lighting Fixtures,” UL 1571...
Yamaguchi, Satoshi; Yamanishi, Yasufumi; Machado, Lucas S; Matsumoto, Shuji; Tovar, Nick; Coelho, Paulo G; Thompson, Van P; Imazato, Satoshi
2018-01-01
The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Fatigue testing showed significantly greater reliability for IN than EX (p<0.001). Fatigue crack initiation was primarily observed at implant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Gait, Balance, Leg Strength, and Sprint Speed After Bedrest with LBNP Exercise
NASA Technical Reports Server (NTRS)
Boda, Wanda L.; Watenbaugh, D. E.; Ballard, R. E.; Fortney, S. M.; Ertl, A. C.; Lee, S. M. C.; William, J. M.; Hargens, Alan R.
1997-01-01
Microgravity and bedrest (BR) result in similar physiological decrements such as loss of muscle mass, muscle strength and balance. Previous studies analyzing exercise within lower body negative pressure (LBNP) have found that gait is similar in LBNP on a vertical treadmill and overground exercise on a horizontal treadmill. Since treadmill exercise is known to increase muscular strength and endurance, we tested the hypothesis that LBNP exercise on a vertical treadmill would prevent or attenuate many of the physical decrements which occur during bedrest. Based on our positive results from diverse tests of post-BR function, we believe that exercise within LBNP is worth pursuing as a countermeasure for reducing the physical deterioration that occurs during bedrest and microgravity.
Self-Aligning Sensor-Mounting Fixture
NASA Technical Reports Server (NTRS)
Gilbert, Jeffrey L.; Mills, Rhonda J.
1991-01-01
Optical welding sensors replaced without realignment. Mounting fixture for optical weld-penetration sensor enables accurate and repeatable alignment. Simple and easy to use. Assembled on welding torch, it holds sensor securely and keeps it pointed toward weld pool. Designed for use on gas/tungsten arc-welding torch, fixture replaces multipiece bracket.
46 CFR 105.30-1 - Electrical fittings and fixtures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Electrical fittings and fixtures. 105.30-1 Section 105... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Electrical Requirements § 105.30-1 Electrical fittings and fixtures. (a) In compartments or areas containing tanks or pumps handling other than...
46 CFR 105.30-1 - Electrical fittings and fixtures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Electrical fittings and fixtures. 105.30-1 Section 105... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Electrical Requirements § 105.30-1 Electrical fittings and fixtures. (a) In compartments or areas containing tanks or pumps handling other than...
46 CFR 105.30-1 - Electrical fittings and fixtures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Electrical fittings and fixtures. 105.30-1 Section 105... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Electrical Requirements § 105.30-1 Electrical fittings and fixtures. (a) In compartments or areas containing tanks or pumps handling other than...
46 CFR 105.30-1 - Electrical fittings and fixtures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Electrical fittings and fixtures. 105.30-1 Section 105... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Electrical Requirements § 105.30-1 Electrical fittings and fixtures. (a) In compartments or areas containing tanks or pumps handling other than...
46 CFR 105.30-1 - Electrical fittings and fixtures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Electrical fittings and fixtures. 105.30-1 Section 105... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Electrical Requirements § 105.30-1 Electrical fittings and fixtures. (a) In compartments or areas containing tanks or pumps handling other than...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
24 CFR 3285.702 - Miscellaneous lights and fixtures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Miscellaneous lights and fixtures... Equipment § 3285.702 Miscellaneous lights and fixtures. (a) When the home is installed, exterior lighting... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...
NASA Technical Reports Server (NTRS)
Winemiller, J. R.; Sullivan, T. L.; Sizemore, R. L.; Yee, S. T.
1979-01-01
It was desired to observe the behavior of a two bladed wind turbine where the tower first bending natural frequency is less than twice the rotor speed. The system then passes through resonance when accelerating to operating speed. The frequency of the original Mod-O tower was reduced by placing it on a spring fixture. The fixture is adjustable to provide a range of tower bending frequencies. Fixture design details are given and behavior during initial operation is described.
Wang, Zhongqi; Yang, Bo; Kang, Yonggang; Yang, Yuan
2016-01-01
Fixture plays an important part in constraining excessive sheet metal part deformation at machining, assembly, and measuring stages during the whole manufacturing process. However, it is still a difficult and nontrivial task to design and optimize sheet metal fixture locating layout at present because there is always no direct and explicit expression describing sheet metal fixture locating layout and responding deformation. To that end, an RBF neural network prediction model is proposed in this paper to assist design and optimization of sheet metal fixture locating layout. The RBF neural network model is constructed by training data set selected by uniform sampling and finite element simulation analysis. Finally, a case study is conducted to verify the proposed method.
Wang, Zhongqi; Yang, Bo; Kang, Yonggang; Yang, Yuan
2016-01-01
Fixture plays an important part in constraining excessive sheet metal part deformation at machining, assembly, and measuring stages during the whole manufacturing process. However, it is still a difficult and nontrivial task to design and optimize sheet metal fixture locating layout at present because there is always no direct and explicit expression describing sheet metal fixture locating layout and responding deformation. To that end, an RBF neural network prediction model is proposed in this paper to assist design and optimization of sheet metal fixture locating layout. The RBF neural network model is constructed by training data set selected by uniform sampling and finite element simulation analysis. Finally, a case study is conducted to verify the proposed method. PMID:27127499
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-03
...-2009-BT-STD-0018] RIN 1904-AC00 Energy Conservation Program: Energy Conservation Standards for Metal... certain metal halide lamp fixtures. This document announces that the period for submitting comments on the... identify the Framework Document for energy conservation standards for metal halide lamp fixtures and...
30 CFR 56.3203 - Rock fixtures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Rock fixtures. 56.3203 Section 56.3203 Mineral... § 56.3203 Rock fixtures. (a) For rock bolts and accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the mine operator shall— (1) Obtain a manufacturer's...
30 CFR 56.3203 - Rock fixtures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Rock fixtures. 56.3203 Section 56.3203 Mineral... § 56.3203 Rock fixtures. (a) For rock bolts and accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the mine operator shall— (1) Obtain a manufacturer's...
30 CFR 57.3203 - Rock fixtures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Rock fixtures. 57.3203 Section 57.3203 Mineral... Support-Surface and Underground § 57.3203 Rock fixtures. (a) For rock bolts and accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the mine operator shall...
30 CFR 56.3203 - Rock fixtures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Rock fixtures. 56.3203 Section 56.3203 Mineral... § 56.3203 Rock fixtures. (a) For rock bolts and accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the mine operator shall— (1) Obtain a manufacturer's...
30 CFR 57.3203 - Rock fixtures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Rock fixtures. 57.3203 Section 57.3203 Mineral... Support-Surface and Underground § 57.3203 Rock fixtures. (a) For rock bolts and accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the mine operator shall...
30 CFR 57.3203 - Rock fixtures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Rock fixtures. 57.3203 Section 57.3203 Mineral... Support-Surface and Underground § 57.3203 Rock fixtures. (a) For rock bolts and accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the mine operator shall...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and Fixture... Applicability; description of the wood furniture and fixture production without water wash spray booth(s) or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and Fixture... Applicability; description of the wood furniture and fixture production without water wash spray booth(s) or...
Optical alignment of the JWST ISIM to the OTE simulator (OSIM): current concept and design studies
NASA Astrophysics Data System (ADS)
Frey, Bradley J.; Davila, Pamela S.; Hagopian, John G.; Marsh, James M.; Ohl, Raymond G.; Wilson, Mark E.; Young, Philip J.
2007-09-01
The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) contains the observatory's four science instruments and their support subsystems. During alignment and test of the integrated ISIM at NASA's Goddard Space Flight Center (GSFC), the Optical telescope element SIMulator (OSIM) will be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to align the OSIM to the ISIM during testing at GSFC. These fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, six degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing. These fixtures will allow us to position the OSIM and detect OSIM-ISIM absolute alignment to better than 180 microns in translation and 540 micro-radians in rotation. We will provide a brief overview of the OSIM system and we will also discuss the relevance of these fixtures in the context of the overall ISIM alignment and test plan.
Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well
Chang, Glenn Hsuan-Chen; Tian, Chen; Hung, Yuen-Siang
2011-01-01
Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented. Results: A clinical case utilizing the fixture mount abutment (DIFMA)/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered. Conclusions: More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment. PMID:22090763
Case study: Fixture water use and drinking water quality in a new residential green building.
Salehi, Maryam; Abouali, Mohammad; Wang, Mian; Zhou, Zhi; Nejadhashemi, Amir Pouyan; Mitchell, Jade; Caskey, Stephen; Whelton, Andrew J
2018-03-01
Residential plumbing is critical for the health and safety of populations worldwide. A case study was conducted to understand fixture water use, drinking water quality and their possible link, in a newly plumbed residential green building. Water use and water quality were monitored at four in-building locations from September 2015 through December 2015. Once the home was fully inhabited average water stagnation periods were shortest at the 2nd floor hot fixture (90 percentile of 0.6-1.2 h). The maximum water stagnation time was 72.0 h. Bacteria and organic carbon levels increased inside the plumbing system compared to the municipal tap water entering the building. A greater amount of bacteria was detected in hot water samples (6-74,002 gene copy number/mL) compared to cold water (2-597 gene copy number/mL). This suggested that hot water plumbing promoted greater microbial growth. The basement fixture brass needle valve may have caused maximum Zn (5.9 mg/L), Fe (4.1 mg/L), and Pb (23 μg/L) levels compared to other fixture water samples (Zn ≤ 2.1 mg/L, Fe ≤ 0.5 mg/L and Pb ≤ 8 μg/L). At the basement fixture, where the least amount of water use events occurred (cold: 60-105, hot: 21-69 event/month) compared to the other fixtures in the building (cold: 145-856, hot: 326-2230 event/month), greater organic carbon, bacteria, and heavy metal levels were detected. Different fixture use patterns resulted in disparate water quality within a single-family home. The greatest drinking water quality changes were detected at the least frequently used fixture. Copyright © 2017 Elsevier Ltd. All rights reserved.
Orofacial contracture management outcomes following partial thickness facial burns.
Clayton, N A; Ward, E C; Maitz, P K M
2015-09-01
To examine clinical outcomes following non-surgical exercise for contracture management post partial thickness orofacial burn. A cohort of 229 patients with partial thickness orofacial burn was recruited over 3 years. Orofacial contracture management combining exercise and stretching was initiated within 48h of admission and continued until functional goals were consistently achieved. A second cohort of 120 healthy controls was recruited for normative comparison. Vertical and horizontal mouth opening measures were recorded at the start and completion of orofacial intervention for patients and once only for controls. At commencement of intervention, participants with orofacial burns had significantly (p<0.001) reduced vertical and horizontal mouth opening. Treatment duration averaged 30.7 days (SD=52.3). Post treatment significant (p<0.001) improvements in vertical and horizontal opening were noted. At treatment conclusion, a significant (p<0.01) difference remained between the burns cohort and control group for vertical mouth opening, though horizontal mouth opening was now statistically comparable to the controls. This study supports positive outcomes following orofacial contracture management for patients with partial thickness orofacial burn. Despite this, some functional loss remained with patients demonstrating persistent reduced vertical mouth opening at conclusion of treatment compared to their healthy counterparts. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Torque-Limiting Manipulation Device
NASA Technical Reports Server (NTRS)
Moetteli, John B. (Inventor)
1999-01-01
A device for manipulating a workpiece in space includes a fixture, a stanchion assembly, a manipulation mechanism, an actuation mechanism, and a reaction mechanism. The fixture has an end onto which the workpiece affixes. The stanchion assembly has an upper and a lower end. The manipulation mechanism connects the fixture and the upper end of the stanchion assembly. The lower end of the stanchion assembly mounts, via probe and a socket, to a structure. The actuation mechanism operably connects to the manipulation mechanism, and moves the fixture in space. The reaction mechanism provides a point through which force inputs into the actuation mechanism may react.
Clifford, Harry J [Los Alamos, NM
2011-03-22
A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and qualification is described, decreasing the time required for such qualification, thus allowing the CMM to be used more productively. A number of embodiments are disclosed that allow for new and retrofit manufacture to perform as integrated calibration sphere and calibration fixture devices. This invention renders unnecessary the removal of a calibration sphere prior to CMM measurement of calibration features on calibration fixtures, thereby greatly reducing the time spent qualifying a CMM.
Fixture for supporting and aligning a sample to be analyzed in an x-ray diffraction apparatus
Green, L.A.; Heck, J.L. Jr.
1985-04-23
A fixture is provided for supporting and aligning small samples of material on a goniometer for x-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the x-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an x-ray diffraction apparatus previously limited to the analysis of much larger samples.
Fixture for supporting and aligning a sample to be analyzed in an X-ray diffraction apparatus
Green, Lanny A.; Heck, Jr., Joaquim L.
1987-01-01
A fixture is provided for supporting and aligning small samples of material on a goniometer for X-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the X-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an X-ray diffraction apparatus previously limited to the analysis of much larger samples.
FY2017 status report: Model 9975 O-ring fixture long-term leak performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daugherty, W. L.
A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially andmore » have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. Leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The 300 °F GLT O-ring fixtures failed after 2.8 to 5.7 years at temperature. The remaining GLT O-ring fixtures aging at 300 ºF were retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 9 to 10.5 years, or in GLT O-ring fixtures aging at 270 ºF for 5.7 years. These aging temperatures bound O-ring temperatures anticipated during normal storage in K-Area Complex (KAC). Leak test failures have been experienced in all of the GLT-S O-ring fixtures aging at 300 ºF and above. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 ºF for 6.9 to 7.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty still exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.« less
Load deflection characteristics of inflated structures
NASA Technical Reports Server (NTRS)
Baumgarten, J. R.
1983-01-01
A single, closed form relationship to relate load to the deformed dimensions of the horizontal torus was developed. Wall elasticity was included in the analysis, and special care was taken to predict the final footprint area of the loaded structure. The test fixture utilized is shown. The tori used for the bulk of the testing were rubber inner tubes for a 32 and 160 pneumatic tire. The inner tube being tested was plumbed, to a mercury-filled manometer, which had a 50 inch measurement capacity, by use of a special adapter. The adapter fit over the valve stem and allowed air to be added from a shop-air source and to be bled through the standard valve mechanism. In this fashion, tests requiring the maintenance of a constant indication of air pressure could be run with little difficulty.
2012-02-16
VANDENBERG AIR FORCE BASE, Calif. -- Technicians move the tilt-rotation fixture holding NASA's NuSTAR spacecraft inside Orbital Sciences' processing facility at Vandenberg Air Force Base, Calif. The spacecraft will be rotated to horizontal for joining with the Pegasus XL rocket. The Orbital Sciences Pegasus will launch NASA's Nuclear Spectroscopic Telescope Array NuSTAR into space. After the rocket and spacecraft are processed at Vandenberg, they will be flown on Orbital's L-1011 carrier aircraft to the Ronald Reagan Ballistic Missile Defense Test Site at the Pacific Ocean’s Kwajalein Atoll for launch. The high-energy x-ray telescope will conduct a census for black holes, map radioactive material in young supernovae remnants, and study the origins of cosmic rays and the extreme physics around collapsed stars. For more information, visit science.nasa.gov/missions/nustar/. Photo credit: NASA/Randy Beaudoin, VAFB
2012-02-16
VANDENBERG AIR FORCE BASE, Calif. -- At Vandenberg Air Force Base's processing facility in California, technicians prepare NASA’s NuSTAR spacecraft to be lifted into a tilt-rotation fixture. The spacecraft will be rotated to horizontal for joining with the Pegasus XL rocket. The Orbital Sciences Pegasus will launch NASA's Nuclear Spectroscopic Telescope Array NuSTAR into space. After the rocket and spacecraft are processed at Vandenberg, they will be flown on Orbital's L-1011 carrier aircraft to the Ronald Reagan Ballistic Missile Defense Test Site at the Pacific Ocean’s Kwajalein Atoll for launch. The high-energy x-ray telescope will conduct a census for black holes, map radioactive material in young supernovae remnants, and study the origins of cosmic rays and the extreme physics around collapsed stars. For more information, visit science.nasa.gov/missions/nustar/. Photo credit: NASA/Randy Beaudoin, VAFB
2012-02-16
VANDENBERG AIR FORCE BASE, Calif. -- At Vandenberg Air Force Base in California, technicians inside Orbital Sciences' processing facility watch as NASA's NuSTAR spacecraft is lifted by the tilt-rotation fixture. The spacecraft will be rotated to horizontal for joining with the Pegasus XL rocket. The Orbital Sciences Pegasus will launch NASA's Nuclear Spectroscopic Telescope Array NuSTAR into space. After the rocket and spacecraft are processed at Vandenberg, they will be flown on Orbital's L-1011 carrier aircraft to the Ronald Reagan Ballistic Missile Defense Test Site at the Pacific Ocean’s Kwajalein Atoll for launch. The high-energy x-ray telescope will conduct a census for black holes, map radioactive material in young supernovae remnants, and study the origins of cosmic rays and the extreme physics around collapsed stars. For more information, visit science.nasa.gov/missions/nustar/. Photo credit: NASA/Randy Beaudoin, VAFB
Fixture For Mounting A Pressure Sensor
NASA Technical Reports Server (NTRS)
Cagle, Christopher M.
1995-01-01
Fixture for mounting pressure sensor in aerodynamic model simplifies task of removal and replacement of sensor in event sensor becomes damaged. Makes it unnecessary to dismantle model. Also minimizes any change in aerodynamic characteristics of model in event of replacement. Removable pressure sensor installed in fixture in wall of model. Wires from sensor pass through channel under surface.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and Fixture...; description of the wood furniture and fixture production with water wash spray booth(s) or with laundry...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and Fixture...; description of the wood furniture and fixture production with water wash spray booth(s) or with laundry...
Gonzalo-Skok, Oliver; Tous-Fajardo, Julio; Valero-Campo, Carlos; Berzosa, César; Bataller, Ana Vanessa; Arjol-Serrano, José Luis; Moras, Gerard; Mendez-Villanueva, Alberto
2017-08-01
To analyze the effects of 2 different eccentric-overload training (EOT) programs, using a rotational conical pulley, on functional performance in team-sport players. A traditional movement paradigm (ie, squat) including several sets of 1 bilateral and vertical movement was compared with a novel paradigm including a different exercise in each set of unilateral and multi-directional movements. Forty-eight amateur or semiprofessional team-sport players were randomly assigned to an EOT program including either the same bilateral vertical (CBV, n = 24) movement (squat) or different unilateral multidirectional (VUMD, n = 24) movements. Training programs consisted of 6 sets of 1 exercise (CBV) or 1 set of 6 exercises (VUMD) × 6-10 repetitions with 3 min of passive recovery between sets and exercises, biweekly for 8 wk. Functional-performance assessment included several change-of-direction (COD) tests, a 25-m linear-sprint test, unilateral multidirectional jumping tests (ie, lateral, horizontal, and vertical), and a bilateral vertical-jump test. Within-group analysis showed substantial improvements in all tests in both groups, with VUMD showing more robust adaptations in pooled COD tests and lateral/horizontal jumping, whereas the opposite occurred in CBV respecting linear sprinting and vertical jumping. Between-groups analyses showed substantially better results in lateral jumps (ES = 0.21), left-leg horizontal jump (ES = 0.35), and 10-m COD with right leg (ES = 0.42) in VUMD than in CBV. In contrast, left-leg countermovement jump (ES = 0.26) was possibly better in CBV than in VUMD. Eight weeks of EOT induced substantial improvements in functional-performance tests, although the force-vector application may play a key role to develop different and specific functional adaptations.
Lighting system combining daylight concentrators and an artificial source
Bornstein, Jonathan G.; Friedman, Peter S.
1985-01-01
A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.
A Hot Dynamic Seal Rig for Measuring Hypersonic Engine Seal Durability and Flow Performance
NASA Technical Reports Server (NTRS)
Miller, Jeffrey H.; Steinetz, Bruce M.; Sirocky, Paul J.; Kren, Lawrence A.
1993-01-01
A test fixture for measuring the dynamic performance of candidate high-temperature engine seal concepts was installed at NASA Lewis Research Center. The test fixture was designed to evaluate seal concepts under development for advanced hypersonic engines, such as those being considered for the National Aerospace Plane (NASP). The fixture can measure dynamic seal leakage performance from room temperature up to 840 C (1550 F) and air pressure differentials up to 690 kPa (100 psi). Performance of the seals can be measured while sealing against flat or distorted walls. In the fixture two seals are preloaded against the sides of a 30 cm (1 ft) long saber that slides transverse to the axis of the seals, simulating the scrubbing motion anticipated in these engines. The capabilities of this test fixture along with preliminary data showing the dependence of seal leakage performance on high temperature cycling are addressed.
Hot dynamic test rig for measuring hypersonic engine seal flow and durability
NASA Technical Reports Server (NTRS)
Miller, Jeffrey H.; Steinetz, Bruce M.; Sirocky, Paul J.; Kren, Lawrence A.
1994-01-01
A test fixture for measuring the dynamic performance of candidate high-temperature engine seal concepts was developed. The test fixture was developed to evaluate seal concepts under development for advanced hypersonic engines, such as those being considered for the National Aerospace Plane (NASP). The fixture can measure dynamic seal leakage performance from room temperature up to 840 C and air pressure differentials of to 0.7 MPa. Performance of the seals can be measured while sealing against flat or engine-simulated distorted walls. In the fixture, two seals are preloaded against the sides of a 0.3 m long saber that slides transverse to the axis of the seals, simulating the scrubbing motion anticipated in these engines. The capabilities of this text fixture along with preliminary data showing the dependence of seal leakage performance on high temperature cycling are covered.
A hot dynamic seal rig for measuring hypersonic engine seal durability and flow performance
NASA Technical Reports Server (NTRS)
Miller, Jeffrey H.; Steinetz, Bruce M.; Sirocky, Paul J.; Kren, Lawrence A.
1993-01-01
A test fixture for measuring the dynamic performance of candidate high-temperature engine seal concepts has been installed at NASA Lewis Research Center. The test fixture has been designed to evaluate seal concepts under development for advanced hypersonic engines, such as those being considered for the National Aerospace Plane (NASP). The fixture can measure dynamic seal leakage performance from room temperature up to 840 C (1550 F) and air pressure differentials up to 690 kPa (100 psi). Performance of the seals can be measured while sealing against flat or distorted walls. In the fixture two seals are preloaded against the sides of a 30 cm (1 ft) long saber that slides transverse to the axis of the seals, simulating the scrubbing motion anticipated in these engines. This report covers the capabilities of this test fixture along with preliminary data showing the dependence of seal leakage performance on high temperature cycling.
An investigation of hardwood plywood markets. Part 2. Fixture manufacturers
Craig L. Forbes; Larry G. Jahn; Philip A. Araman
2001-01-01
This is the second part of a two-part study investigating markets for hardwood plywood. Part 1 dealt with architectural woodworkers. North American fixture manufacturers were surveyed to better understand the structure and use of wood-based panels in the industry. A questionnaire was mailed to a sample of U.S. and Canadian fixture manufacturers. The sample consisted of...
Mammalian Toxicology Testing: Problem Definition Study, Technical Plan.
1981-03-01
Acute Oral Exposure Area, Rzdent 2. Subchrcnic Oral Exposure Area, .odent 3. Chronic Oral Exposure Area, Rodent 4. Subchronic Oral Eposure Area, "og...Alarms Fire Extinguisher First Aid Fiscal Year Record Fixtures (See Jigs, Fixtures & Molds Control System) Food Preparation/Blending Forms Control...Insurance Invoicing (See Bookkeeping) Janitorial Service Jigs, Fixtures & Molds Control System Key Control System Keypunch Control System Label
Apparatus for correcting precision errors in slide straightness in machine tools
Robinson, Samuel C.; Gerth, Howard L.
1981-01-01
The present invention is directed to a mechanism by which small deviations in slideway straightness and roll of a precision machining apparatus may be compensated for. The mechanism of the present invention comprises a fixture support disposed between the slideway carriage and the tool or workpiece fixture and provided with a hinge-like coupling between the carriage and the fixture support so as to allow for the minute and precise displacement of the fixture support in a direction normal to the direction of the slide path so as to readily compensate for slight deviations in the straightness and roll of the slide path.
Apparatus for correcting precision errors in slide straigntness in machine tools
Robinson, S.C.; Gerth, H.L.
The present invention is directed to a mechanism by which small deviations in slideway straightness and roll of a precision machining apparatus may be compensated for. The mechanism of the present invention comprises a fixture support disposed between the slideway carriage and the tool or workpiece fixture and provided with a hinge-like coupling between the carriage and the fixture support so as to allow for the minute and precise displacement of the fixture support in a direction normal to the direction of the slide path soa as to readily compensate for slight deviations in the straightness and roll of the slide path.
Sadrimanesh, Roozbeh; Siadat, Hakimeh; Sadr-Eshkevari, Pooyan; Monzavi, Abbas; Maurer, Peter; Rashad, Ashkan
2012-06-01
To comparatively assess the masticatory stress distribution in bone around implants placed in the anterior maxilla with three different labial inclinations. Three-dimensional finite element models were fabricated for three situations in anterior maxilla: (1) a fixture in contact with buccal cortical plate restored by straight abutment, (2) a fixture inclined at 15 degrees, and (3) 20 degrees labially restored with corresponding angled abutment. A palatal bite force of 146 N was applied to a point 3 mm below the incisal edge. Stress distribution around the bone-fixture interface was determined using ANSYS software. The maximum compressive stress, concentrated in the labial crestal cortical bone, was measured to be 62, 108, and 122 MPa for 0-, 15-, and 20-degree labially inclined fixtures, respectively. The maximum tensile stress, concentrated in the palatal crestal cortical bone, was measured to be 60, 108, and 120 MPa for 0-, 15-, and 20-degree labially inclined fixtures, respectively. While all compressive stress values were under the cortical yield strength of 169 MPa, tensile stress values partially surpassed the yield strength (104 MPa) especially when a 20-degree inclination was followed for fixture placement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, Kelly L.; Foster, Rebecca; McGowan, Terry
This article for a building trade magazine describes a national design competition for energy efficient lighting sponsored by the U.S. Department of Energy, the American Lighting Association, and the Consortium for Energy Efficiency, with winners announced at ALA's Annual Conference May 14, 2004, in Tucson. The Lighting for Tomorrow competition was the first national lighting fixture design competition focusing on energy-efficient residential lighting. The competition invited fixture manufacturers and designers to come up with beautiful, functional lighting fixtures that also happen to be energy efficient. Fixtures were required to use a ''dedicated'' energy-efficient light source, such as a pin-based fluorescentmore » lamp that cannot be replaced with a screw-in incandescent bulb. Fixtures also had to meet a minimum energy efficiency level that eliminated use of incandescent and halogen lamps, leaving the door open only to fluorescent sources and LEDs. More than 150 paper designs were submitted in the first phase of the competition, in 2003. Of those, 24 finalists were invited to submit working prototypes in 2004, and the winners were announced in May. The Grand Prize of $10,000 went to American Fluorescent of Waukegan, Illinois, for its ''Salem'' chandelier. Some winning fixtures are already available through Lowe's Home Improvement Centers.« less
F-15B/Flight Test Fixture 2: A Test Bed for Flight Research
NASA Technical Reports Server (NTRS)
Richwine, David M.
1996-01-01
NASA Dryden Flight Research Center has developed a second-generation flight test fixture for use as a generic test bed for aerodynamic and fluid mechanics research. The Flight Test Fixture 2 (FTF-2) is a low-aspect-ratio vertical fin-like shape that is mounted on the centerline of the F-I5B lower fuselage. The fixture is designed for flight research at Mach numbers to a maximum of 2.0. The FTF-2 is a composite structure with a modular configuration and removable components for functional flexibility. This report documents the flow environment of the fixture, such as surface pressure distributions and boundary-layer profiles, throughout a matrix of conditions within the F-15B/FTF-2 flight envelope. Environmental conditions within the fixture are presented to assist in the design and testing of future avionics and instrumentation. The intent of this document is to serve as a user's guide and assist in the development of future flight experiments that use the FTF-2 as a test bed. Additional information enclosed in the appendices has been included to assist with more detailed analyses, if required.
Murphy, William J.; Fackler, Cameron J.; Berger, Elliott H.; Shaw, Peter B.; Stergar, Mike
2015-01-01
Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL. PMID:26356380
NASA Astrophysics Data System (ADS)
Murthy, G.; Watenpaugh, D. E.; Ballard, R. E.; Hargens, A. R.
Exposure to lower body negative pressure (LBNP) with oral salt and water ingestion has been tested by astronauts as a countermeasure to prevent postflight orthostatic intolerance. Exercise is another countermeasure that astronauts commonly use during spaceflight to maintain musculoskeletal strength. We hypothesize that a novel combination of exercise and simultaneous exposure to lower body negative pressure during spaceflight will produce Earth-like musculoskeletal loads as well as cardiovascular stimuli to maintain adaptation to Earth's gravity. Results from recent studies indicate that leg exercise within a LBNP chamber against the suction force of 100 mmHg LBNP in horizontal-supine posture produces an equivalent, if not greater exercise stress compared to similar leg exercise in upright posture (without LBNP) against Earth's gravity. 12 Therefore, the concept of LBNP combined with exercise may prove to be a low cost and low mass technique to stress the cardiovascular and the musculoskeletal systems simultaneously.
Why Is It Harder to Run on an Inclined Exercise Treadmill?
ERIC Educational Resources Information Center
Nave, Carla M. A. P. F.; Amoreira, Luis J. M.
2014-01-01
It is a known fact that it takes a greater effort to run on an exercise treadmill when it is inclined with positive slope than when it is in a horizontal position. The reason seems simple: walking on an inclined treadmill is somehow equivalent to walking up a hill with the same inclination; when we walk up a hill, our own weight does negative work…
Choi, Woo-Jeong; Yoon, Tae-Lim; Choi, Sil-Ah; Lee, Ji-Hyun; Cynn, Heon-Seock
2017-07-01
The aim of the present study was to determine whether the application of isometric horizontal abduction (IHA) differentially affected two weight-bearing push-up plus exercises by examining activation of the scapulothoracic muscles in subjects with scapular winging. Fifteen male subjects performed standard push-up plus (SPP) and wall push-up plus (WPP), with and without IHA. Two-way analyses of variance using two within-subject factors were used to determine the statistical significance of observed differences in upper trapezius (UT), pectoralis major (PM), and serratus anterior (SA) muscle activities and UT/SA and PM/SA muscle activity ratios. UT and SA muscle activities were greater during SPP than WPP. PM muscle activity was lower with IHA application. The UT/SA and PM/SA muscle activity ratios were lower during SPP than WPP. The PM/SA muscle activity ratio was lower with IHA application. The results suggest that IHA application using a Thera-Band can effectively reduce PM muscle activity during SPP and WPP exercises. Moreover, the SPP exercise can be used to increase UT and SA muscle activity and reduce the UT/SA and PM/SA muscle activity ratios in subjects with scapular winging. Copyright © 2016 Elsevier Ltd. All rights reserved.
Explosive Venting Technology for Cook-Off Response Mitigation
2010-07-01
endplate blew off 188.3 PAX-28 Go 6.4 Explode, HE boiled out, body banana peeled 177.8 PAX-28 No go 7.6 Burn, HE boiled out of fixture, smoking, then burn...PAX-28 5.1-mm diameter vent test was to blow off the top fixture and peel off three out of the four heating bands while leaving the fixture in its
Compact Fluorescent Plug-In Ballast-in-a-Socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rebecca Voelker
2001-12-21
The primary goal of this program was to develop a ballast system for plug-in CFLs (compact fluorescent lamps) that will directly replace standard metal shell, medium base incandescent lampholders (such as Levition No. 6098) for use with portable lamp fixtures, such as floor, table and desk lamps. A secondary goal was to identify a plug-in CFL that is optimized for use with this ballast. This Plug-in CFL Ballastin-a-Socket system will allow fixture manufacturers to easily manufacture CFL-based high-efficacy portable fixtures that provide residential and commercial consumers with attractive, cost-effective, and energy-efficient fixtures for use wherever portable incandescent fixtures are usedmore » today. The advantages of this proposed system over existing CFL solutions are that the fixtures can only be used with high-efficacy CFLs, and they will be more attractive and will have lower life-cycle costs than screw-in or adapter-based CFL retrofit solutions. These features should greatly increase the penetration of CFL's into the North American market. Our work has shown that using integrated circuits it is quite feasible to produce a lamp-fixture ballast of a size comparable to the current Edison-screw 3-way incandescent fixtures. As for price points for BIAS-based fixtures, end-users polled by the Lighting Research Institute at RPI indicated that they would pay as much as an additional $10 for a lamp containing such a ballast. The ballast has been optimized to run with a 26 W amalgam triple biax lamp in the base-down position, yet can accept non-amalgam versions of the lamp. With a few part alterations, the ballast can be produced to support 32 W lamps as well. The ballast uses GE's existing L-Comp[1] power topology in the circuit so that the integrated circuit design would be a design that could possibly be used by other CFL and EFL products with minor modifications. This gives added value by reducing cost and size of not only the BIAS, but also possibly other integral CFL and future dimmable integral and plug-in versions of the EFL products.« less
Tsai, Ming-June; Wu, Ching-Tsai
2014-05-06
This study aimed to establish surgical guiding techniques for completing mandible lesion resection and reconstruction of the mandible defect area with fibula sections in one surgery by applying additive manufacturing technology, which can reduce the surgical duration and enhance the surgical accuracy and success rate. A computer assisted mandible reconstruction planning (CAMRP) program was used to calculate the optimal cutting length and number of fibula pieces and design the fixtures for mandible cutting, registration, and arrangement of the fibula segments. The mandible cutting and registering fixtures were then generated using an additive manufacturing system. The CAMRP calculated the optimal fibula cutting length and number of segments based on the location and length of the defective portion of the mandible. The mandible cutting jig was generated according to the boundary surface of the lesion resection on the mandible STL model. The fibular cutting fixture was based on the length of each segment, and the registered fixture was used to quickly arrange the fibula pieces into the shape of the defect area. In this study, the mandibular lesion was reconstructed using registered fibular sections in one step, and the method is very easy to perform. The application of additive manufacturing technology provided customized models and the cutting fixtures and registered fixtures, which can improve the efficiency of clinical application. This study showed that the cutting fixture helped to rapidly complete lesion resection and fibula cutting, and the registered fixture enabled arrangement of the fibula pieces and allowed completion of the mandible reconstruction in a timely manner. Our method can overcome the disadvantages of traditional surgery, which requires a long and different course of treatment and is liable to cause error. With the help of optimal cutting planning by the CAMRP and the 3D printed mandible resection jig and fibula cutting fixture, this all-in-one process of mandible reconstruction furnishes many benefits in this field by enhancing the accuracy of surgery, shortening the operation duration, reducing the surgical risk, and resulting in a better mandible appearance of the patients after surgery.
2014-01-01
Background This study aimed to establish surgical guiding techniques for completing mandible lesion resection and reconstruction of the mandible defect area with fibula sections in one surgery by applying additive manufacturing technology, which can reduce the surgical duration and enhance the surgical accuracy and success rate. Methods A computer assisted mandible reconstruction planning (CAMRP) program was used to calculate the optimal cutting length and number of fibula pieces and design the fixtures for mandible cutting, registration, and arrangement of the fibula segments. The mandible cutting and registering fixtures were then generated using an additive manufacturing system. The CAMRP calculated the optimal fibula cutting length and number of segments based on the location and length of the defective portion of the mandible. The mandible cutting jig was generated according to the boundary surface of the lesion resection on the mandible STL model. The fibular cutting fixture was based on the length of each segment, and the registered fixture was used to quickly arrange the fibula pieces into the shape of the defect area. In this study, the mandibular lesion was reconstructed using registered fibular sections in one step, and the method is very easy to perform. Results and conclusion The application of additive manufacturing technology provided customized models and the cutting fixtures and registered fixtures, which can improve the efficiency of clinical application. This study showed that the cutting fixture helped to rapidly complete lesion resection and fibula cutting, and the registered fixture enabled arrangement of the fibula pieces and allowed completion of the mandible reconstruction in a timely manner. Our method can overcome the disadvantages of traditional surgery, which requires a long and different course of treatment and is liable to cause error. With the help of optimal cutting planning by the CAMRP and the 3D printed mandible resection jig and fibula cutting fixture, this all-in-one process of mandible reconstruction furnishes many benefits in this field by enhancing the accuracy of surgery, shortening the operation duration, reducing the surgical risk, and resulting in a better mandible appearance of the patients after surgery. PMID:24885749
Technical activities report: Heat, water, and mechanical studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexander, W.K.
1951-10-04
Topics in the heat studies section include: front and rear face reflector shields at the C-pile; process tube channel thermocouples; water temperature limits for horizontal rods; slug temperature and thermal conductivity calculations; maximum slug-end cap temperature; boiling consideration studies; scram time limit for Panellit alarm; heat transfer test; slug stresses; thermal insulation of bottom tube row at C-pile; flow tests; present pile enrichment; electric analog; and measurement of thermal contact resistance. Topics in the water studies section include: 100-D flow laboratory; process water studies; fundamental studies on film formation; coatings on tip-offs; can difference tests; slug jacket abrasion at highmore » flow rates; corrosion studies; front tube dummy slugs; metallographic examination of tubes from H-pile; fifty-tube mock-up; induction heating facility; operational procedures and standards; vertical safety rod dropping time tests; recirculation; and power recovery. Mechanical development studies include: effect of Sphincter seal and lubricant VSR drop time; slug damage; slug bubble tester; P-13 removal; chemical slug stripper; effect of process tube rib spacing and width; ink facility installation; charging and discharging machines; process tube creep; flapper nozzle assembly test; test of single gun barrel assembly; pigtail fixture test; horizontal rod gland seal test; function test of C-pile; and intermediate test of Ball 3-X and VSR systems.« less
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
1998-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
2001-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Machining fixture layout optimization using particle swarm optimization algorithm
NASA Astrophysics Data System (ADS)
Dou, Jianping; Wang, Xingsong; Wang, Lei
2011-05-01
Optimization of fixture layout (locator and clamp locations) is critical to reduce geometric error of the workpiece during machining process. In this paper, the application of particle swarm optimization (PSO) algorithm is presented to minimize the workpiece deformation in the machining region. A PSO based approach is developed to optimize fixture layout through integrating ANSYS parametric design language (APDL) of finite element analysis to compute the objective function for a given fixture layout. Particle library approach is used to decrease the total computation time. The computational experiment of 2D case shows that the numbers of function evaluations are decreased about 96%. Case study illustrates the effectiveness and efficiency of the PSO based optimization approach.
Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report.
Naert, I; Quirynen, M; Theuniers, G; van Steenberghe, D
1991-05-01
Eighty-six consecutive patients, provided with 84 resilient and two nonresilient overdentures (six in the upper and 80 in the lower jaw), were examined. The overdentures were supported by a total of 173 osseointegrated titanium fixtures (the standard Branemark abutment), with a mean loading time of 19.1 months (range 4 to 48 months). In each jaw only two fixtures anchored the overdentures. No failures occurred during the observation period but two fixtures were lost before loading. The radiographic annual bone loss around fixtures in the lower jaw was -0.8 mm for the first year and less than -0.1 mm for the following years. The change in marginal bone height did not correlate with parameters such as the occlusion and articulation pattern, the presence or absence of a soft liner around the abutments, and the magnitude of the interabutment distance. The patients' reactions to overdenture treatment were, on the whole, positive concerning chewing function, phonetics, and comfort. The need for maintenance care of the clip-bar attachment was minimal.
Multiple direction vibration fixture
Cericola, Fred; Doggett, James W.; Ernest, Terry L.; Priddy, Tommy G.
1991-01-01
An apparatus for simulating a rocket launch environment on a test item undergoing centrifuge testing by subjecting the item simultaneously or separately to vibration along an axis of centripetal force and along an axis perpendicular to the centripetal force axis. The apparatus includes a shaker motor supported by centrifuge arms and a right angle fixture pivotally connected to one of the shaker motor mounts. When the shaker motor vibrates along the centripetal force axis, the vibrations are imparted to a first side of the right angle fixture. The vibrations are transmitted 90 degrees around the pivot and are directed to a second side of the right angle fixture which imparts vibrations perpendicular to the centripetal force axis. The test item is in contact with a third side of the right angle fixture and receives both centripetal-force-axis vibrations and perpendicular axis vibrations simultaneously. A test item can be attached to the third side near the flexible coupling or near the air bag to obtain vibrations along the centripetal force axis or transverse to the centripetal force axis.
Method and apparatus for air-coupled transducer
NASA Technical Reports Server (NTRS)
Song, Junho (Inventor); Chimenti, Dale E. (Inventor)
2010-01-01
An air-coupled transducer includes a ultrasonic transducer body having a radiation end with a backing fixture at the radiation end. There is a flexible backplate conformingly fit to the backing fixture and a thin membrane (preferably a metallized polymer) conformingly fit to the flexible backplate. In one embodiment, the backing fixture is spherically curved and the flexible backplate is spherically curved. The flexible backplate is preferably patterned with pits or depressions.
Using Bonding Enamel-Coated Steel Fixtures to Produce More Durable Brick/Masonry Structures
2010-02-01
Initial tests with enameled metal straps cracked all the test cylinders and straps would not pull out BUILDING STRONG® New Strong Durable Ties...BUILDING STRONG® Using Bonding Enamel -Coated Steel Fixtures to Produce More Durable Brick/Masonry Structures Principal Investigator: Steven C...COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Using Bonding Enamel -Coated Steel Fixtures to Produce More Durable Brick/Masonry
Extended Life PZT Stack Test Fixture
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Sherrit, S.; Bao, X.; Aldrich, J.; Bar-Cohen, Y.; Jones, C.
2009-01-01
Piezoelectric stacks are being sought to be used as actuators for precision positioning and deployment of mechanisms in future planetary missions. Beside the requirement for very high operation reliability, these actuators are required for operation at space environments that are considered harsh compared to normal terrestrial conditions.These environmental conditions include low and high temperatures and vacuum or high pressure. Additionally, the stacks are subjected to high stress and in some applications need to operate with a very long lifetime durability.Many of these requirements are beyond the current industry design margins for nominal terrestrial applications. In order to investigate some of the properties that will indicate the durability of such actuators and their limitations we have developed a new type of test fixture that can be easily integrated in various test chambers for simulating environmental conditions, can provide access for multiple measurements while being exposed to adjustable stress levels. We designed and built two test fixtures and these fixtures were made to be adjustable for testing stacks with different dimensions and can be easily used in small or large numbers. The properties that were measured using these fixtures include impedance, capacitance, dielectric loss factor, leakage current, displacement, breakdown voltage, and lifetime performance. The fixtures characteristics and the test capabilities are presented in this paper.
Effects of exercise on fluid exchange and body composition in man during 14-day bed rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Juhos, L. T.; Young, H. L.; Morse, J. T.; Staley, R. W.
1977-01-01
A description is presented of an investigation in which body composition, fluid intake, and fluid and electrolyte losses were measured in seven normal, healthy men during three 2-wk bed-rest periods, separated by two 3-wk recovery periods. During bed rest the subjects remained in the horizontal position continuously. During the dietary control periods, body mass decreased significantly with all three regimens, including no exercise, isometric exercise, and isotonic excercise. During bed rest, body mass was essentially unchanged with no exercise, but decreased significantly with isotonic and isometric exercise. With one exception, there were no statistically significant changes in body density, lean body mass, or body fat content by the end of each of the three bed-rest periods.
A method for accounting for test fixture compliance when estimating proximal femur stiffness.
Rossman, Timothy; Dragomir-Daescu, Dan
2016-09-06
Fracture testing of cadaveric femora to obtain strength and stiffness information is an active area of research in developing tools for diagnostic prediction of bone strength. These measurements are often used in the estimation and validation of companion finite element models constructed from the femora CT scan data, therefore, the accuracy of the data is of paramount importance. However, experimental stiffness calculated from force-displacement data has largely been ignored by most researchers due to inherent error in the differential displacement measurement obtained when not accounting for testing apparatus compliance. However, having such information is necessary for validation of computational models. Even in the few cases when fixture compliance was considered the measurements showed large lab-to-lab variation due to lack of standardization in fixture design. We examined the compliance of our in-house designed cadaveric femur test fixture to determine the errors we could expect when calculating stiffness from the collected experimental force-displacement data and determined the stiffness of the test fixture to be more than 10 times the stiffness of the stiffest femur in a sample of 44 femora. When correcting the apparent femur stiffness derived from the original data, we found that the largest stiffness was underestimated by about 10%. The study confirmed that considering test fixture compliance is a necessary step in improving the accuracy of fracture test data for characterizing femur stiffness, and highlighted the need for test fixture design standardization for proximal femur fracture testing. Copyright © 2016 Elsevier Ltd. All rights reserved.
2014-08-29
CAPE CANAVERAL, Fla. – Inside the Delta Operations Center at Cape Canaveral Air Force Station, United Launch Alliance technicians place the second stage of a Delta IV Heavy rocket on a support fixture following testing in preparation for the unpiloted Exploration Flight Test-1, or EFT-1. The second stage will be placed on a transporter for the move to the Horizontal Integration Facility at Space Launch Complex 37 for mating with the Delta IV Heavy booster stages. During the mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on the first flight test is planned for December 2014. Photo credit: NASA/Kim Shiflett
2012-02-17
VANDENBERG AIR FORCE BASE, Calif. – Inside an environmental enclosure at Vandenberg Air Force Base's processing facility in California, technicians check the interface of NASA's Nuclear Spectroscopic Telescope Array, or NuSTAR, with its Orbital Sciences Pegasus XL rocket. The spacecraft is secured inside the turnover rotation fixture used to rotate it into a horizontal position. The uniting of the spacecraft with the rocket is a major milestone in prelaunch preparations. After processing of the rocket and spacecraft are complete, they will be flown on Orbital's L-1011 carrier aircraft from Vandenberg to the Ronald Reagan Ballistic Missile Defense Test Site on the Pacific Ocean’s Kwajalein Atoll for launch. The high-energy x-ray telescope will conduct a census of black holes, map radioactive material in young supernovae remnants, and study the origins of cosmic rays and the extreme physics around collapsed stars. For more information, visit http://www.nasa.gov/nustar. Photo credit: NASA/Randy Beaudoin, VAFB
Plasma Chamber Design and Fabrication Activities
NASA Astrophysics Data System (ADS)
Parodi, B.; Bianchi, A.; Cucchiaro, A.; Coletti, A.; Frosi, P.; Mazzone, G.; Pizzuto, A.; Ramogida, G.; Coppi, B.
2006-10-01
A fabrication procedure for a typical Plasma Chamber (PC) sector has been developed to cover all the manufacturing phases, from the raw materials specification (including metallurgical processes) to the machining operations, acceptance procedures and vacuum tests. Basically, the sector is made of shaped elements (forged or rolled) welded together using special fixtures and then machined to achieve the final dimensional accuracy. An upgraded design of the plasma chamber's vertical support that can withstand the estimated electromagnetic loads (Eddy and Halo current plus horizontal net force resulting from the worst plasma disruption scenario VDE, Vertical Displacement Event) has been completed. The maintenance of the radial support can take place hands-on with a direct access from outside the cryostat. With the present design, vacuum tightness is achieved by welding conducted with automatic welding heads. On the outer surface of the PC a dedicated duct system, filled by helium gas, is included to cool down the PC to room temperature when needed.
Testing Machine for Biaxial Loading
NASA Technical Reports Server (NTRS)
Demonet, R. J.; Reeves, R. D.
1985-01-01
Standard tensile-testing machine applies bending and tension simultaneously. Biaxial-loading test machine created by adding two test fixtures to commercial tensile-testing machine. Bending moment applied by substrate-deformation fixture comprising yoke and anvil block. Pneumatic tension-load fixture pulls up on bracket attached to top surface of specimen. Tension and deflection measured with transducers. Modified test apparatus originally developed to load-test Space Shuttle surface-insulation tiles and particuarly important for composite structures.
Alignment and testing of critical interface fixtures for the James Webb Space Telescope
NASA Astrophysics Data System (ADS)
McLean, Kyle; Bagdanove, Paul; Berrier, Joshua; Cofie, Emmanuel; Glassman, Tiffany; Hadjimichael, Theodore; Johnson, Eric; Levi, Joshua; Lo, Amy; McMann, Joseph; Ohl, Raymond; Osgood, Dean; Parker, James; Redman, Kevin; Roberts, Vicki; Stephens, Matthew; Sutton, Adam; Wenzel, Greg; Young, Jerrod
2017-08-01
NASA's James Webb Space Telescope (JWST) is a 6.5m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Primary Mirror Backplane Support Structure (PMBSS) and Integrated Science Instrument Module (ISIM) Electronics Compartment (IEC) which is designed to integrate to the spacecraft bus via six cup/cone interfaces. Prior to integration to the spacecraft bus, the JWST observatory must undergo environmental testing, handling, and transportation. Multiple fixtures were developed to support these tasks including the vibration fixture and handling and integration fixture (HIF). This work reports on the development of the nominal alignment of the six interfaces and metrology operations performed for the JWST observatory to safely integrate them for successful environmental testing.
Alignment and Testing of Critical Interface Fixtures for the James Webb Space Telescope
NASA Technical Reports Server (NTRS)
Mclean, Kyle; Bagdanove, Paul; Berrier, Joshua; Cofie, Emmanuel; Glassman, Tiffany; Hadjimichael, Theodore; Johnson, Eric; Levi, Joshua; Lo, Amy; McMann, Joseph;
2017-01-01
NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Primary Mirror Backplane Support Structure (PMBSS) and Integrated Science Instrument Module (ISIM) Electronics Compartment (IEC) which is designed to integrate to the spacecraft bus via six cup/cone interfaces. Prior to integration to the spacecraft bus the JWST observatory must undergo environmental testing, handling, and transportation. Multiple fixtures were developed to support these tasks including the vibration fixture and handling and integration fixture (HIF). This work reports on the development of the nominal alignment of the six interfaces and metrology operations performed for the JWST observatory to safely integrate them for successful environmental testing.
Alignment and Testing of Critical Interface Fixtures for the James Webb Space Telescope
NASA Technical Reports Server (NTRS)
Mclean, Kyle; Bagdanove, Paul; Berrier, Joshua; Cofie, Emmanuel; Glassman, Tiffany; Hadjimichael, Theodore; Johnson, Eric; Levi, Joshua; Lo, Amy; McMann, Joseph;
2017-01-01
NASAs James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Primary Mirror Backplane Support Structure (PMBSS) and Integrated Science Instrument Module (ISIM) Electronics Compartment (IEC) which is designed to integrate to the spacecraft bus via six cupcone interfaces. Prior to integration to the spacecraft bus the JWST observatory must undergo environmental testing, handling, and transportation. Multiple fixtures were developed to support these tasks including the vibration fixture and handling and integration fixture (HIF). This work reports on the development of the nominal alignment of the six interfaces and metrology operations performed for the JWST observatory to safely integrate them for successful environmental testing.
Reflector system for a lighting fixture
Siminovitch, M.J.; Page, E.; Gould, C.T.
1998-09-08
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope. 5 figs.
Methods and apparatus for optical switching using electrically movable optical fibers
Peterson, Kenneth A [Albuquerque, NM
2007-03-13
Methods and apparatuses for electrically controlled optical switches are presented. An electrically controlled optical switch includes a fixture formed using a laminated dielectric material, a first optical fiber having a fixed segment supported by the fixture and a movable segment extending into a cavity, a second optical fiber having a fixed segment supported by the fixture and an extended segment where an optical interconnect may be established between the first optical fiber and the second optical fiber, and a first electrical actuator functionally coupled to the fixture and the first fiber which alters a position of the moveable segment, based upon a control signal, for changing a state of the optical interconnect between one of two states.
NASA Technical Reports Server (NTRS)
Lih, Shyh-Shiuh (Inventor); Takano, Nobuyuki (Inventor); Lee, Hyeong Jae (Inventor); Bao, Xiaoqi (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Sherrit, Stewart (Inventor); Ostlund, Patrick N. (Inventor)
2017-01-01
A high temperature ultrasonic probe and a mounting fixture for attaching and aligning the probe to a steam pipe using blind alignment. The high temperature ultrasonic probe includes a piezoelectric transducer having a high temperature. The probe provides both transmitting and receiving functionality. The mounting fixture allows the high temperature ultrasonic probe to be accurately aligned to the bottom external surface of the steam pipe so that the presence of liquid water in the steam pipe can be monitored. The mounting fixture with a mounted high temperature ultrasonic probe are used to conduct health monitoring of steam pipes and to track the height of condensed water through the wall in real-time.
Effect of mat pilates exercise on postural alignment and body composition of middle-aged women.
Lee, Hyo Taek; Oh, Hyun Ok; Han, Hui Seung; Jin, Kwang Youn; Roh, Hyo Lyun
2016-06-01
[Purpose] This study attempted to examine whether Pilates is an effective exercise for improving the postural alignment and health of middle-aged women. [Subjects and Methods] The participants in this study were 36 middle-aged women (20 in the experimental group, 16 in the control group). The experimental group participated in Pilates exercise sessions three times a week for 12 weeks. Body alignment and composition measurements before and after applying the Pilates exercise program were performed with a body composition analyzer and a three-dimensional scanner. [Results] Postural alignment in the sagittal and horizontal planes was enhanced in the Pilates exercise group. Trunk alignment showed correlations with body fat and muscle mass. [Conclusion] The Pilates exercises are performed symmetrically and strengthen the deep muscles. Moreover, the results showed that muscle mass was correlated with trunk postural alignment and that the proper amount of muscle is critical in maintaining trunk postural alignment.
NASA Technical Reports Server (NTRS)
Coker, Bill E.
1988-01-01
Fixture delimits peened area precisely while boosting productivity. New fixture ensures small tolerances essential for turbine blades. Opens and closes quickly so finished part removed and new part inserted.
Rehabilitation Exercises to Induce Balanced Scapular Muscle Activity in an Anti-gravity Posture
Ishigaki, Tomonobu; Yamanaka, Masanori; Hirokawa, Motoki; Tai, Keita; Ezawa, Yuya; Samukawa, Mina; Tohyama, Harukazu; Sugawara, Makoto
2014-01-01
[Purpose] The purpose of this study was to compare the intramuscular balance ratios of the upper trapezius muscle (UT) and the lower trapezius muscle (LT), and the intermuscular balance ratios of the UT and the serratus anterior muscle (SA) among prone extension (ProExt), prone horizontal abduction with external rotation (ProHAbd), forward flexion in the side-lying position (SideFlex), side-lying external rotation (SideEr), shoulder flexion with glenohumeral horizontal abduction load (FlexBand), and shoulder flexion with glenohumeral horizontal adduction load (FlexBall) in the standing posture. [Methods] The electromyographic (EMG) activities of the UT, LT and SA were measured during the tasks. The percentage of maximum voluntary isometric contraction (%MVIC) was calculated for each muscle, and the UT/LT ratios and the UT/SA ratios were compared among the tasks. [Results] The UT/LT ratio with the FlexBand was not significantly different from those of the four exercises in the side-lying and prone postures. The UT/SA ratio with the FlexBall demonstrated appropriate balanced activity. [Conclusion] In an anti-gravity posture, we recommend the FlexBand and the FlexBall for inducing balanced UT/LT and UT/SA ratios, respectively. PMID:25540485
Rehabilitation Exercises to Induce Balanced Scapular Muscle Activity in an Anti-gravity Posture.
Ishigaki, Tomonobu; Yamanaka, Masanori; Hirokawa, Motoki; Tai, Keita; Ezawa, Yuya; Samukawa, Mina; Tohyama, Harukazu; Sugawara, Makoto
2014-12-01
[Purpose] The purpose of this study was to compare the intramuscular balance ratios of the upper trapezius muscle (UT) and the lower trapezius muscle (LT), and the intermuscular balance ratios of the UT and the serratus anterior muscle (SA) among prone extension (ProExt), prone horizontal abduction with external rotation (ProHAbd), forward flexion in the side-lying position (SideFlex), side-lying external rotation (SideEr), shoulder flexion with glenohumeral horizontal abduction load (FlexBand), and shoulder flexion with glenohumeral horizontal adduction load (FlexBall) in the standing posture. [Methods] The electromyographic (EMG) activities of the UT, LT and SA were measured during the tasks. The percentage of maximum voluntary isometric contraction (%MVIC) was calculated for each muscle, and the UT/LT ratios and the UT/SA ratios were compared among the tasks. [Results] The UT/LT ratio with the FlexBand was not significantly different from those of the four exercises in the side-lying and prone postures. The UT/SA ratio with the FlexBall demonstrated appropriate balanced activity. [Conclusion] In an anti-gravity posture, we recommend the FlexBand and the FlexBall for inducing balanced UT/LT and UT/SA ratios, respectively.
Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester
NASA Technical Reports Server (NTRS)
Vailhe, Christophe
2003-01-01
The figure shows a fixture for measuring the tensile strength of the bond between an aluminum substrate and a thermally insulating polymeric foam. The specimen is meant to be representative of insulating foam on an aluminum tank that holds a cryogenic liquid. Prior to the development of this fixture, tensile tests of this type were performed on foam/substrate specimens immersed in cryogenic fluids. Because the specimens were cooled to cryogenic temperatures throughout their thicknesses, they tended to become brittle and to fracture at loads below true bond tensile strengths. The present fixture is equipped to provide a thermal gradient from cryogenic temperature at the foam/substrate interface to room temperature on the opposite foam surface. The fixture includes an upper aluminum block at room temperature and a lower aluminum block cooled to -423 F (approx. -253 C) by use of liquid helium. In preparation for a test, the metal outer surface (the lower surface) of a foam/substrate specimen is bonded to the lower block and the foam outer surface (the upper surface) of the specimen is bonded to the upper block. In comparison with the through-the-thickness cooling of immersion testing, the cryogenic-to-room-temperature thermal gradient that exists during testing on this fixture is a more realistic approximation of the operational thermal condition of sprayed insulating foam on a tank of cryogenic liquid. Hence, tensile tests performed on this fixture provide more accurate indications of operational bond tensile strengths. In addition, the introduction of the present fixture reduces the cost of testing by reducing the amount of cryogenic liquid consumed and the time needed to cool a specimen.
Environmental Assessment for Replace Family Housing Phase IV at Malmstrom Air Force Base, Montana
2003-08-15
effects of hard water and corrosion, resulting in severe constriction and pipe leakage, and plumbing fixtures are worn and discolored and require... piping and plumbing fixtures, electrical wiring and lighting fixtures, cabinets, and finish work. All of the room layouts would remain the same since...Falls. The USFWS has classified the Missouri River as a Wild and Scenic River from the confluence with the Teton River, which is 50 miles northeast and
NASA Astrophysics Data System (ADS)
Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf
2017-10-01
For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.
Park, Young-Jin; Cho, Sung-Am
2010-06-01
To evaluate the survival rate of implants placed in the maxillary tuberosity region using the fixed prosthesis in partially edentulous cases. Of implant-treated patients who visited Kyung Pook National University Hospital, 7 partially edentulous patients (2 male and 5 female; mean age, 52.3 years; range, approximately 43 to 65) were selected according to the following criteria: 1) less than 3-mm thickness alveolar bone reaming at the first molar area and 2) 1 to 2 fixture premolars, with the additional implant at the maxillary tuberosity region. For the control group, patients who had nontuberosity areas were selected. After 1 to 7 years, marginal bone level, fixture mobility, and radiolucency of tuberosity fixtures of the fixed prostheses were evaluated by digital panorama (Starpacs, Infinitt, Seoul, Korea). None of the fixtures of the tuberosity-installed implants for 1 to 7 years failed. The marginal bone level around the implants of the maxillary tuberosity 1 to 6 years (average 3.4 years) after the final prostheses was approximately 0.6 to 1.3 mm, with an average of 0.94 mm. The fixture installation at the maxillary tuberosity using the unilateral partially edentulous implant-fixed prosthesis would be a clinically acceptable treatment module. 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Measuring alignment of loading fixture
Scavone, Donald W.
1989-01-01
An apparatus and method for measuring the alignment of a clevis and pin type loading fixture for compact tension specimens include a pair of substantially identical flat loading ligaments. Each loading ligament has two apertures for the reception of a respective pin of the loading fixture and a thickness less than one-half of a width of the clevis opening. The pair of loading ligaments are mounted in the clevis openings at respective sides thereof. The loading ligaments are then loaded by the pins of the loading fixture and the strain in each loading ligament is measured. By comparing the relative strain of each loading ligament, the alignment of the loading fixture is determined. Preferably, a suitable strain gage device is located at each longitudinal edge of a respective loading ligament equidistant from the two apertures in order to determine the strain thereat and hence the strain of each ligament. The loading ligaments are made substantially identical by jig grinding the loading ligaments as a matched set. Each loading ligament can also be individually calibrated prior to the measurement.
Results from a Test Fixture for button BPM Trapped Mode Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cameron,P.; Bacha, B.; Blednykh, A.
2009-05-04
A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1)more » Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.« less
Effects of horizontal plyometric training volume on soccer players' performance.
Yanci, Javier; Los Arcos, Asier; Camara, Jesús; Castillo, Daniel; García, Alberto; Castagna, Carlo
2016-01-01
The aim of this study was to examine the dose response effect of strength and conditioning programmes, involving horizontally oriented plyometric exercises, on relevant soccer performance variables. Sixteen soccer players were randomly allocated to two 6-week plyometric training groups (G1 and G2) differing by imposed (twice a week) training volume. Post-training G1 (4.13%; d = 0.43) and G2 (2.45%; d = 0.53) moderately improved their horizontal countermovement jump performance. Significant between-group differences (p < 0.01) in the vertical countermovement jump for force production time (T2) were detected post-training. No significant and practical (p > 0.05, d = trivial or small) post-training improvements in sprint, change of direction ability (CODA) and horizontal arm swing countermovement jump were reported in either group. Horizontal plyometric training was effective in promoting improvement in injury prevention variables. Doubling the volume of a horizontal plyometric training protocol was shown to have no additional effect over functional aspects of soccer players' performance.
Kim, Mi-Kyoung; Lee, Jung Chul; Yoo, Kyung-Tae
2018-03-01
[Purpose] The purpose of this study was to analyze the effects of pectoralis minor stretching and shoulder strengthening with an elastic band on balance and maximal shoulder muscle strength in young adults with rounded shoulder posture. [Subjects and Methods] Nineteen subjects with rounded shoulder posture were randomly divided into 2 groups: a shoulder stabilization exercise group and a stretching exercise group. The groups performed each exercise for 40 minutes, 3 times a week, for 4 weeks. Static balance (eyes open and closed), dynamic balance (the limits of stability in 4 directions) and shoulder muscle strength in 5 directions were measure before and after the exercises. [Results] The stretching exercise demonstrated a significant difference between the pre- and post-exercise in the static balance with eyes closed and extension and horizontal abduction strength while the stabilization exercise demonstrated significant difference in the left and right directions between the pre- and post-exercise of the dynamic balance and flexion strength. The stabilization exercise demonstrated significant differences shown in the flexion between the pre- and post-test. [Conclusion] The shoulder stabilization and stretching exercises improved the static balance, dynamic balance, and muscle strength.
NASA Technical Reports Server (NTRS)
Laakso, J. H.; Smith, D. D.; Zimmerman, D. K.
1973-01-01
The fabrication of two shear web test elements and three large scale shear web test components are reported. In addition, the fabrication of test fixtures for the elements and components is described. The center-loaded beam test fixtures were configured to have a test side and a dummy or permanent side. The test fixtures were fabricated from standard extruded aluminum sections and plates and were designed to be reuseable.
Simulation of pyroshock environments using a tunable resonant fixture
Davie, N.T.
1996-10-15
Disclosed are a method and apparatus for simulating pyrotechnic shock for the purpose of qualifying electronic components for use in weapons, satellite, and aerospace applications. According to the invention, a single resonant bar fixture has an adjustable resonant frequency in order to exhibit a desired shock response spectrum upon mechanical impact. The invention eliminates the need for availability of a large number of different fixtures, capable of exhibiting a range of shock response characteristics, in favor of a single tunable system. 32 figs.
NASA Technical Reports Server (NTRS)
Romanofsky, Robert R.; Shalkhauser, Kurt A.
1989-01-01
The design and evaluation of a novel fixturing technique for characterizing millimeter wave solid state devices is presented. The technique utilizes a cosine-tapered ridge guide fixture and a one-tier de-embedding procedure to produce accurate and repeatable device level data. Advanced features of this technique include nondestructive testing, full waveguide bandwidth operation, universality of application, and rapid, yet repeatable, chip-level characterization. In addition, only one set of calibration standards is required regardless of the device geometry.
Grinding Parts For Automatic Welding
NASA Technical Reports Server (NTRS)
Burley, Richard K.; Hoult, William S.
1989-01-01
Rollers guide grinding tool along prospective welding path. Skatelike fixture holds rotary grinder or file for machining large-diameter rings or ring segments in preparation for welding. Operator grasps handles to push rolling fixture along part. Rollers maintain precise dimensional relationship so grinding wheel cuts precise depth. Fixture-mounted grinder machines surface to quality sufficient for automatic welding; manual welding with attendant variations and distortion not necessary. Developed to enable automatic welding of parts, manual welding of which resulted in weld bead permeated with microscopic fissures.
Simulation of pyroshock environments using a tunable resonant fixture
Davie, Neil T.
1996-01-01
Disclosed are a method and apparatus for simulating pyrotechnic shock for the purpose of qualifying electronic components for use in weapons, satellite, and aerospace applications. According to the invention, a single resonant bar fixture has an adjustable resonant frequency in order to exhibit a desired shock response spectrum upon mechanical impact. The invention eliminates the need for availability of a large number of different fixtures, capable of exhibiting a range of shock response characteristics, in favor of a single tunable system.
Cutburth, Ronald W.; Smauley, David A.
1987-01-01
A clamp or dog is disclosed which preferably comprises a slotted stepped cylindrical body which is inserted into a hole in a workpiece and then fastened to a base or fixture using a screw which is inserted through the slot. The stepped configuration provides an annular clamping surface which securely clamps the workpiece against the base or fixture. The slotted cylindrical configuration permits adjustment of the workpiece and retaining clamp in any direction, i.e., over 360.degree., relative to the mounting position of the screw in the base or fixture.
Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies
NASA Technical Reports Server (NTRS)
Frey, Bradley J.; Davila, Pamela S.; Marsh, James M.; Ohl, Raymond G.; Sullivan, Joseph
2007-01-01
The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) is the scientific payload of the observatory and contai ns four science instruments. During alignment and test of the integrated ISIM (i.e. ISIM + science instruments) at NASA's Goddard Space Fli ght Center (GSFC), the Optical telescope element SIMulator (OSIM) wil l be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. The se fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, 6 degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing.
Ball mounting fixture for a roundness gage
Gauler, Allen L.; Pasieka, Donald F.
1983-01-01
A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball.
NASA Astrophysics Data System (ADS)
Latief, Yusuf; Berawi, Mohammed Ali; Basten, Van; Riswanto; Budiman, Rachmat
2017-07-01
Green building concept becomes important in current building life cycle to mitigate environment issues. The purpose of this paper is to optimize building construction performance towards green building premium cost, achieving green building rating tools with optimizing life cycle cost. Therefore, this study helps building stakeholder determining building fixture to achieve green building certification target. Empirically the paper collects data of green building in the Indonesian construction industry such as green building fixture, initial cost, operational and maintenance cost, and certification score achievement. After that, using value engineering method optimized green building fixture based on building function and cost aspects. Findings indicate that construction performance optimization affected green building achievement with increasing energy and water efficiency factors and life cycle cost effectively especially chosen green building fixture.
Sinking and fit of abutment of locking taper implant system
Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung
2009-01-01
STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262
Apparatus for restraining and transporting dies
Allison, James W.; LaBarre, Timothy L.
1994-01-01
Apparatus for restraining and transporting dies in punch press operations is provided. A floatation platen for supporting a die on the platen's upper surface has a plurality of recessed gas exhaust ports on the platen's lower surface. A source of pressurized gas delivers gas to a platen manifold, for delivery to orifices located in the gas exhaust ports. The flow of gas is controlled by a first valve adjacent the gas source and a second valve adjacent the manifold, with the second valve being used to control the gas flow during movement of the die. In this fashion, a die may be moved on a cushion of air from one workstation to a selected second workstation. A moveable hydraulically operated restraining fixture is also provided, for clamping the die in position during the compacting phase, and for releasing the die after completion of the compacting phase by releasing the hydraulic pressure on the restraining fixture. When pressure in the hydraulic cylinders on the restraining fixture is reversed, the restraining fixture will retract so that there is no contact between the die and the restraining fixture, thereby allowing the die to be removed from a first workstation and moved to a second selected workstation.
Rotating Juno for Integrating Instruments
2010-07-12
Once the radiation vault was installed on top of the propulsion module, NASA Juno spacecraft was lifted onto a large rotation fixture. The fixture allows the spacecraft to be turned for convenient access for integrating and testing instruments.
Blind-Anchor-Nut-Installation Fixture (BANIF)
NASA Technical Reports Server (NTRS)
Willey, Norman F., Jr.; Linker, James F.
1994-01-01
Blind-anchor-nut-installation fixture, BANIF, developed for replacing or installing anchor nuts in blind holes or other inaccessible places. Attachment of anchor nut to BANIF enables placement of anchor nut on blind side of component.
Detail; Street Car Waiting House, support for exterior light fixture ...
Detail; Street Car Waiting House, support for exterior light fixture - North Philadelphia Station, Street Car Waiting House, 2900 North Broad Street, on northwest corner of Broad Street & Glenwood Avenue, Philadelphia, Philadelphia County, PA
46 CFR 129.410 - Lighting fixtures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... fixture must have a high-strength guard or be made of high-strength material, except in accommodations... Studio Lighting Units,” or UL 1574, “Track Lighting Systems,” as long as the general marine requirements...
46 CFR 129.410 - Lighting fixtures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... fixture must have a high-strength guard or be made of high-strength material, except in accommodations... Studio Lighting Units,” or UL 1574, “Track Lighting Systems,” as long as the general marine requirements...
46 CFR 129.410 - Lighting fixtures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... fixture must have a high-strength guard or be made of high-strength material, except in accommodations... Studio Lighting Units,” or UL 1574, “Track Lighting Systems,” as long as the general marine requirements...
46 CFR 129.410 - Lighting fixtures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... fixture must have a high-strength guard or be made of high-strength material, except in accommodations... Studio Lighting Units,” or UL 1574, “Track Lighting Systems,” as long as the general marine requirements...
10 CFR 431.321 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures § 431.321 Purpose and scope. This subpart contains energy conservation requirements for metal halide lamp ballasts and fixtures, pursuant to Part A of Title III of the...
10 CFR 431.321 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures § 431.321 Purpose and scope. This subpart contains energy conservation requirements for metal halide lamp ballasts and fixtures, pursuant to Part A-1 of Title III of the...
VIEW OF LAMP FIXTURE (EXTERIOR) ADJACENT TO ENTRANCE AT SOUTHWEST ...
VIEW OF LAMP FIXTURE (EXTERIOR) ADJACENT TO ENTRANCE AT SOUTHWEST CORNER OF BUILDING 23, FACING NORTH - Roosevelt Base, Auditorium-Gymnasium, West Virginia Street between Richardson & Reeves Avenues, Long Beach, Los Angeles County, CA
10 CFR 431.321 - Purpose and scope.
Code of Federal Regulations, 2014 CFR
2014-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures § 431.321 Purpose and scope. This subpart contains energy conservation requirements for metal halide lamp ballasts and fixtures, pursuant to Part A of Title III of the...
10 CFR 431.321 - Purpose and scope.
Code of Federal Regulations, 2013 CFR
2013-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures § 431.321 Purpose and scope. This subpart contains energy conservation requirements for metal halide lamp ballasts and fixtures, pursuant to Part A of Title III of the...
10 CFR 431.321 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures § 431.321 Purpose and scope. This subpart contains energy conservation requirements for metal halide lamp ballasts and fixtures, pursuant to Part A of Title III of the...
Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku
2012-01-01
The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.
High-performance space shuttle auxiliary propellant valve system
NASA Technical Reports Server (NTRS)
Smith, G. M.
1973-01-01
Several potential valve closures for the space shuttle auxiliary propulsion system (SS/APS) were investigated analytically and experimentally in a modeling program. The most promising of these were analyzed and experimentally evaluated in a full-size functional valve test fixture of novel design. The engineering investigations conducted for both model and scale evaluations of the SS/APS valve closures and functional valve fixture are described. Preliminary designs, laboratory tests, and overall valve test fixture designs are presented, and a final recommended flightweight SS/APS valve design is presented.
Welding fixture for nuclear fuel pin cladding assemblies
Oakley, David J.; Feld, Sam H.
1986-01-01
A welding fixture for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.
Bandwidth increasing mechanism by introducing a curve fixture to the cantilever generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Weiqun, E-mail: weiqunliu@home.swjtu.edu.cn; Liu, Congzhi; Ren, Bingyu
2016-07-25
A nonlinear wideband generator architecture by clamping the cantilever beam generator with a curve fixture is proposed. Devices with different nonlinear stiffness can be obtained by properly choosing the fixture curve according to the design requirements. Three available generator types are presented and discussed for polynomial curves. Experimental investigations show that the proposed mechanism effectively extends the operation bandwidth with good power performance. Especially, the simplicity and easy feasibility allow the mechanism to be widely applied for vibration generators in different scales and environments.
Effect of mat pilates exercise on postural alignment and body composition of middle-aged women
Lee, Hyo Taek; Oh, Hyun Ok; Han, Hui Seung; Jin, Kwang Youn; Roh, Hyo Lyun
2016-01-01
[Purpose] This study attempted to examine whether Pilates is an effective exercise for improving the postural alignment and health of middle-aged women. [Subjects and Methods] The participants in this study were 36 middle-aged women (20 in the experimental group, 16 in the control group). The experimental group participated in Pilates exercise sessions three times a week for 12 weeks. Body alignment and composition measurements before and after applying the Pilates exercise program were performed with a body composition analyzer and a three-dimensional scanner. [Results] Postural alignment in the sagittal and horizontal planes was enhanced in the Pilates exercise group. Trunk alignment showed correlations with body fat and muscle mass. [Conclusion] The Pilates exercises are performed symmetrically and strengthen the deep muscles. Moreover, the results showed that muscle mass was correlated with trunk postural alignment and that the proper amount of muscle is critical in maintaining trunk postural alignment. PMID:27390396
Joint US/USSR study: Comparison of effects of horizontal and head-down bed rest
NASA Technical Reports Server (NTRS)
Sandler, Harold; Grigoriev, Anatoli I.
1990-01-01
An account is given of the results of the first joint U.S./U.S.S.R. bed rest study. The study was accomplished in two parts: A soviet part (May to June 1979) and an American part (July to August 1979). Both studies were conducted under identical conditions and provided a basis for comparison of physiologic reactions and standardizing procedures and methods. Each experiment consisted of three periods: 14 days of pre-bed rest control, 7 days of bed rest, and a 10 to 14 day recovery period. Ten males participated in each study, with five subjects experiencing horizontal bed rest and five subjects a -6 deg head-down body position. Biochemical and hormonal measurements were made of blood and urine, with particular attention to electrolyte metabolism and kidney function; cardio-pulmonary changes at rest and exercise; influence of Lower Body Negative Pressure (LBNP); and incremental exercise using a bicyle ergometer while supine and sitting. Expected moderate changes were noted to occur for various physiologic parameters. Clinical evidence pointed to the fact that head-down bed rest when compared to horizontal conditions more closely matched the conditions seen after manned spaceflight. For the most part, statistically significant differences between the two body positions were not observed.
Full thickness facial burns: Outcomes following orofacial rehabilitation.
Clayton, N A; Ward, E C; Maitz, P K M
2015-11-01
To document orofacial rehabilitation and outcomes after full thickness orofacial burn. Participants included 12 consecutive patients presenting with full thickness orofacial burns. A group of 120 age-matched healthy participants was recruited for normative comparison. Non-surgical exercise was initiated within 48 h of admission and continued until wounds had healed, circumoral scar tissue had stabilised and functional goals were achieved to the best of the patient's ability. Outcomes were documented using vertical and horizontal mouth opening measures at start and end of treatment and therapy duration was recorded. At commencement of treatment, participants had significantly (p<0.001) reduced vertical and horizontal mouth opening range compared to controls. Average duration of orofacial contracture management was 550 days, with half requiring >2 years rehabilitation. By end of treatment, significant (p<0.01) positive improvement in vertical and horizontal mouth opening had been achieved, however measures had returned to lower limits of normal function and remained significantly (p<0.05) reduced compared to the control group. This study demonstrates that although positive gains can be achieved through non-surgical exercise after full thickness burn, the duration of rehabilitation is considerable and some degree of long term loss in functional mouth opening remains. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Detail view of bronze light fixture on on north facade, ...
Detail view of bronze light fixture on on north facade, lower level - Blue Ridge Sanatorium, Building No. 1902, East side of State Route 20, .25 mile south of I-64, Charlottesville, Independent City, VA
Detail view of stylized railing and bronze light fixture on ...
Detail view of stylized railing and bronze light fixture on southwest facade - Blue Ridge Sanatorium, Building No. 1901, East side of State Route 20, .25 mile south of I-64, Charlottesville, Independent City, VA
Fixture for winding transformers
NASA Technical Reports Server (NTRS)
Mclyman, M. T.
1980-01-01
Bench-mounted fixture assists operator in winding toroid-shaped transformer cores. Toroid is rigidly held in place as wires are looped around. Arrangement frees both hands for rapid winding and untangling of wires that occurs when core is hand held.
Connector For Embedded Optical Fiber
NASA Technical Reports Server (NTRS)
Wilkerson, Charles; Hiles, Steven; Houghton, J. Richard; Holland, Brent W.
1994-01-01
Partly embedded fixture is simpler and sturdier than other types of outlets for optical fibers embedded in solid structures. No need to align coupling prism and lenses. Fixture includes base, tube bent at 45 degree angle, and ceramic ferrule.
Ball mounting fixture for a roundness gage
Gauler, A.L.; Pasieka, D.F.
1983-11-15
A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball. 6 figs.
Tubular hydrogen permeable metal foil membrane and method of fabrication
Paglieri, Stephen N.; Birdsell, Stephen A.; Barbero, Robert S.; Snow, Ronny C.; Smith, Frank M.
2006-04-04
A tubular hydrogen permeable metal membrane and fabrication process comprises obtaining a metal alloy foil having two surfaces, coating the surfaces with a metal or metal alloy catalytic layer to produce a hydrogen permeable metal membrane, sizing the membrane into a sheet with two long edges, wrapping the membrane around an elongated expandable rod with the two long edges aligned and overlapping to facilitate welding of the two together, placing the foil wrapped rod into a surrounding fixture housing with the two aligned and overlapping foil edges accessible through an elongated aperture in the surrounding fixture housing, expanding the elongated expandable rod within the surrounding fixture housing to tighten the foil about the expanded rod, welding the two long overlapping foil edges to one another generating a tubular membrane, and removing the tubular membrane from within the surrounding fixture housing and the expandable rod from with the tubular membrane.
Comparison of theoretical and flight-measured local flow aerodynamics for a low-aspect-ratio fin
NASA Technical Reports Server (NTRS)
Johnson, J. B.; Sandlin, D. R.
1984-01-01
Flight test and theoretical aerodynamic data were obtained for a flight test fixture mounted on the underside of an F-104G aircraft. The theoretical data were generated using two codes, a two dimensional transonic code called Code H, and a three dimensional subsonic and supersonic code call wing-body. Pressure distributions generated by the codes for the flight test fixture as well as boundary layer displacement thickness generated by the two dimensional code were compared to the flight test data. The two dimensional code pressure distributions compared well except at the minimum pressure point and trailing edge. Shock locations compared well except at high transonic speeds. The three dimensional code pressure distributions compared well except at the trailing edge of the flight test fixture. The two dimensional code does not predict displacement thickness of the flight test fixture well.
Russell, Mark; Birch, Jack; Love, Thomas; Cook, Christian J; Bracken, Richard M; Taylor, Tom; Swift, Eamon; Cockburn, Emma; Finn, Charlie; Cunningham, Daniel; Wilson, Laura; Kilduff, Liam P
2017-02-01
Russell, M, Birch, J, Love, T, Cook, CJ, Bracken, RM, Taylor, T, Swift, E, Cockburn, E, Finn, C, Cunningham, D, Wilson, L, and Kilduff, LP. The effects of a single whole-body cryotherapy exposure on physiological, performance, and perceptual responses of professional academy soccer players after repeated sprint exercise. J Strength Cond Res 31(2): 415-421, 2017-In professional youth soccer players, the physiological, performance, and perceptual effects of a single whole-body cryotherapy (WBC) session performed shortly after repeated sprint exercise were investigated. In a randomized, counterbalanced, and crossover design, 14 habituated English Premier League academy soccer players performed 15 × 30 m sprints (each followed by a 10 m forced deceleration) on 2 occasions. Within 20 minutes of exercise cessation, players entered a WBC chamber (Cryo: 30 seconds at -60° C, 120 seconds at -135° C) or remained seated (Con) indoors in temperate conditions (∼25° C). Blood and saliva samples, peak power output (countermovement jump), and perceptual indices of recovery and soreness were assessed pre-exercise and immediately, 2-hour and 24-hour postexercise. When compared with Con, a greater testosterone response was observed at 2-hour (+32.5 ± 32.3 pg·ml, +21%) and 24-hour (+50.4 ± 48.9 pg·ml, +28%) postexercise (both P = 0.002) in Cryo (trial × treatment interaction: P = 0.001). No between-trial differences were observed for other salivary (cortisol and testosterone/cortisol ratio), blood (lactate and creatine kinase), performance (peak power output), or perceptual (recovery or soreness) markers (all trial × treatment interactions: P > 0.05); all of which were influenced by exercise (time effects: all P ≤ 0.05). A single session of WBC performed within 20 minutes of repeated sprint exercise elevated testosterone concentrations for 24 hours but did not affect any other performance, physiological, or perceptual measurements taken. Although unclear, WBC may be efficacious for professional soccer players during congested fixture periods.
Test program, helium II orbital resupply coupling
NASA Technical Reports Server (NTRS)
Hyatt, William S.
1991-01-01
The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.
NASA Astrophysics Data System (ADS)
Lavoie, J. Andre; Morton, John
1993-07-01
A crush test fixture for measuring energy absorption of flat plate specimens from an earlier study was redesigned to eliminate the problem of binding of the load transfer platen with the guide posts. Further modifications were to increase the stroke, and combine the two scaled text fixtures into one. This new crush text fixture was shown to produce load-displacement histories exhibiting well developed sustained crushing loads over long strokes. An experimental study was conducted on two material systems: AS4/3502 graphite/epoxy, and a hybrid AS4-Kevlar/3502 composite. The effect of geometric scaling of specimen size, the effect of ply level and sublaminate-level scaling of the stacking sequence of the full scale specimens, and the effect of trigger mechanism on the energy absorption capability were investigated. The new crush test fixture and flat plate specimens produced peak and sustained crushing loads that were lower than obtained with the old crush text fixture. The trigger mechanism used influenced the specific sustained crushing stress (SSCS). The results indicated that to avoid any reduction in the SSCS when scaling from the 1/2 scale to full scale specimen size, the sublaminate-level scaling approach should be used, in agreement with experiments on tubes. The use of Kevlar in place of the graphite 45 deg plies was not as effective a means for supporting and containing the 0 deg graphite plies for rushing of flat plates and resulted in a drop in the SSCS. This result did not correlate with that obtained for tubes.
NASA Technical Reports Server (NTRS)
Lavoie, J. Andre; Morton, John
1993-01-01
A crush test fixture for measuring energy absorption of flat plate specimens from an earlier study was redesigned to eliminate the problem of binding of the load transfer platen with the guide posts. Further modifications were to increase the stroke, and combine the two scaled text fixtures into one. This new crush text fixture was shown to produce load-displacement histories exhibiting well developed sustained crushing loads over long strokes. An experimental study was conducted on two material systems: AS4/3502 graphite/epoxy, and a hybrid AS4-Kevlar/3502 composite. The effect of geometric scaling of specimen size, the effect of ply level and sublaminate-level scaling of the stacking sequence of the full scale specimens, and the effect of trigger mechanism on the energy absorption capability were investigated. The new crush test fixture and flat plate specimens produced peak and sustained crushing loads that were lower than obtained with the old crush text fixture. The trigger mechanism used influenced the specific sustained crushing stress (SSCS). The results indicated that to avoid any reduction in the SSCS when scaling from the 1/2 scale to full scale specimen size, the sublaminate-level scaling approach should be used, in agreement with experiments on tubes. The use of Kevlar in place of the graphite 45 deg plies was not as effective a means for supporting and containing the 0 deg graphite plies for rushing of flat plates and resulted in a drop in the SSCS. This result did not correlate with that obtained for tubes.
NASA Astrophysics Data System (ADS)
Darmawan, Tofiq Dwiki; Priadythama, Ilham; Herdiman, Lobes
2018-02-01
Welding and drilling are main processes of making chair frame from metal material. Commonly, chair frame construction includes many arcs which bring difficulties for its welding and drilling process. In UNS industrial engineering integrated practicum there are welding fixtures which use to fixing frame component position for welding purpose. In order to achieve exact holes position for assembling purpose, manual drilling processes were conducted after the frame was joined. Unfortunately, after it was welded the frame material become hard and increase drilling tools wear rate as well as reduce holes position accuracy. The previous welding fixture was not equipped with clamping system and cannot accommodate drilling process. To solve this problem, our idea is to reorder the drilling process so that it can be execute before welding. Thus, this research aims to propose conceptual design of modular fixture which can integrate welding and drilling process. We used Generic Product Development Process to address the design concept. We collected design requirements from 3 source, jig and fixture theoretical concepts, user requirements, and clamping part standards. From 2 alternatives fixture tables, we propose the first which equipped with mounting slots instead of holes. We test the concept by building a full sized prototype and test its works by conducting welding and drilling of a student chair frame. Result from the welding and drilling trials showed that the holes are on precise position after welding. Based on this result, we conclude that the concept can be a consideration for application in UNS Industrial Engineering Integrated Practicum.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... 20. * * * The plumbing fixtures in all the restrooms perform a discrete and critical function in the... fixtures in the hotel building perform a discrete and critical function in the operation of the plumbing...
Portable track loading fixture improvement.
DOT National Transportation Integrated Search
2012-12-01
The portable track loading fixture (PTLF) has been used in the field as a nondestructive means of testing track strength, as per the Federal Railroad Administrations (FRA) Track Safety Standards (TSS) 49 CFR 213.110 (m). The PTLF operates by pla...
Fixture facilitates soldering operations
NASA Technical Reports Server (NTRS)
White, C. M.
1968-01-01
Soldering fixture, designed for printed circuit cards, is a basic bench-mounted, self-contained integral unit combining all soldering needs into a compact, readily available work station. All tools, materials, and accessories are available to provide an ideal station to perform critical soldering.
Ranchordas, Mayur Krachna; Dawson, Joel T; Russell, Mark
2017-01-01
Specific guidelines that aim to facilitate the recovery of soccer players from the demands of training and a congested fixture schedule are lacking; especially in relation to evidence-based nutritional recommendations. The importance of repeated high level performance and injury avoidance while addressing the challenges of fixture scheduling, travel to away venues, and training commitments requires a strategic and practically feasible method of implementing specific nutritional strategies. Here we present evidence-based guidelines regarding nutritional recovery strategies within the context of soccer. An emphasis is placed on providing practically applicable guidelines for facilitation of recovery when multiple matches are played within a short period of time (i.e. 48 h). Following match-play, the restoration of liver and muscle glycogen stores (via consumption of ~1.2 g⋅kg -1 ⋅h -1 of carbohydrate) and augmentation of protein synthesis (via ~40 g of protein) should be prioritised in the first 20 min of recovery. Daily intakes of 6-10 g⋅kg -1 body mass of carbohydrate are recommended when limited time separates repeated matches while daily protein intakes of >1.5 g⋅kg -1 body mass should be targeted; possibly in the form of multiple smaller feedings (e.g., 6 × 20-40 g). At least 150% of the body mass lost during exercise should be consumed within 1 h and electrolytes added such that fluid losses are ameliorated. Strategic use of protein, leucine, creatine, polyphenols and omega-3 supplements could also offer practical means of enhancing post-match recovery.
Machine tools and fixtures: A compilation
NASA Technical Reports Server (NTRS)
1971-01-01
As part of NASA's Technology Utilizations Program, a compilation was made of technological developments regarding machine tools, jigs, and fixtures that have been produced, modified, or adapted to meet requirements of the aerospace program. The compilation is divided into three sections that include: (1) a variety of machine tool applications that offer easier and more efficient production techniques; (2) methods, techniques, and hardware that aid in the setup, alignment, and control of machines and machine tools to further quality assurance in finished products: and (3) jigs, fixtures, and adapters that are ancillary to basic machine tools and aid in realizing their greatest potential.
SFR test fixture for hemispherical and hyperhemispherical camera systems
NASA Astrophysics Data System (ADS)
Tamkin, John M.
2017-08-01
Optical testing of camera systems in volume production environments can often require expensive tooling and test fixturing. Wide field (fish-eye, hemispheric and hyperhemispheric) optical systems create unique challenges because of the inherent distortion, and difficulty in controlling reflections from front-lit high resolution test targets over the hemisphere. We present a unique design for a test fixture that uses low-cost manufacturing methods and equipment such as 3D printing and an Arduino processor to control back-lit multi-color (VIS/NIR) targets and sources. Special care with LED drive electronics is required to accommodate both global and rolling shutter sensors.
Heat transfer assembly for a fluorescent lamp and fixture
Siminovitch, Michael J.; Rubenstein, Francis M.; Whitman, Richard E.
1992-01-01
In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.
Welding fixture for nuclear fuel pin cladding assemblies
Oakley, D.J.; Feld, S.H.
1984-02-22
A welding fixture is described for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.
A new surgical and technical approach in zygomatic implantology
GRECCHI, F.; BIANCHI, A.E.; SIERVO, S.; GRECCHI, E.; LAURITANO, D.
2017-01-01
SUMMARY Purpose Different surgical approaches for zygomatic implantology using new designed implants are reported. Material and methods The surgical technique is described and two cases reported. The zygomatic fixture has a complete extrasinus path in order to preserve the sinus membrane and to avoid any post-surgical sinus sequelae. Results The surgical procedure allows an optimal position of the implant and consequently an ideal emergence of the fixture on the alveolar crest. Conclusion The surgical procedures and the zygomatic implant design reduce remarkably the serious post-operative sequelae due to the intrasinus path of the zygomatic fixtures. PMID:29876045
Sperier, Aubrey D.; Hopkins, Colleen F.; Griffiths, Bridgette D.; Principe, Molly F.; Schnall, Barri L.; Bell, Johanna C.; Koppenhaver, Shane L.
2016-01-01
ABSTRACT Background Body armor is credited with increased survival rates in soldiers but the additional axial load may negatively impact the biomechanics of the spine resulting in low back pain. Multiple studies have found that lumbar stabilization programs are superior to generalized programs for patients with chronic low back pain. It is not known if such programs produce objective changes in trunk muscle function with wear of body armor. Hypothesis/Purpose An eight-week core stability exercise program would result in a larger improvement in physical endurance and abdominal muscle thickness than a control intervention. The purpose of this study was to assess the effectiveness of an eight-week core stability exercise program on physical endurance and abdominal muscle thickness with and without wear of body armor. Study Design Randomized controlled trial Methods Participants (N = 33) were randomized into either the core strengthening exercise group or the control group. Testing included ultrasound imaging of abdominal muscle thickness in hook-lying and standing with and without body armor and timed measures of endurance. Results There were statistically significant group by time interactions for transversus abdominis muscle contraction thickness during standing, both with (p = 0.018) and without body armor (p = 0.038). The main effect for hold-time during the horizontal side-support (p = 0.016) indicated improvement over time regardless of group. There was a significant group by time interaction (p = 0.014) for horizontal side-support hold-time when compliance with the exercise protocol was set at 85%, indicating more improvement in the core stabilization group than in the control group. Conclusion Performing an eight-week core stabilization exercise program significantly improves transversus abdominis muscle activation in standing and standing with body armor. When compliant with the exercises, such a program may increase trunk strength and muscle endurance. Levels of Evidence Therapy, Level 2b PMID:27525175
Fixture for assembling solar panels
NASA Technical Reports Server (NTRS)
Dillard, P. A.; Fritz, W. M.
1979-01-01
Vacuum fixture attaches array of silicon solar cells to mounting plate made of clear glass which holds and protects cells. Glass plate transmits, rather than absorbs, solar energy thus cooling cells for efficient operation. Device therefore reduces handling of cells and interconnecting conductors to one operation.
Space vehicle electromechanical system and helical antenna winding fixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judd, Stephen; Dallmann, Nicholas; Guenther, David
A space vehicle electromechanical system may employ an architecture that enables convenient and practical testing, reset, and retesting of solar panel and antenna deployment on the ground. A helical antenna winding fixture may facilitate winding and binding of the helical antenna.
Handling fixture for soldering round wires to FCC
NASA Technical Reports Server (NTRS)
Loggins, R.; Martineck, H. G.
1971-01-01
Fixture holds flat conductor cable and wires in position until after soldering of contacting conductor ends and potting of junctions. Device provides for proper spacing of wires and adequate access for soldered joints during fabrication, and positions mold halves during potting operation.
F-15B in on ramp with close-up of test panels covered with advanced spray-on foam insulation materia
NASA Technical Reports Server (NTRS)
1999-01-01
Test panels covered with an advanced foam insulation material for the Space Shuttle's giant external fuel tank were test flown aboard an F-15B research aircraft at NASA's Dryden Flight Research Center, Edwards, Calif. Six panels were mounted on the left side of a heavily instrumented Flight Text Fixture mounted underneath the F-15B's fuselage. Insulation on this panel was finely machined over a horizontal rib structure to simulate in-line airflow past the tank; other panels had the ribs mounted vertically or had the insulation left in a rough as-sprayed surface. The tests were part of an effort by NASA's Marshall Space Flight Center to determine why small particles of the new insulation flaked off the tank on recent Shuttle missions. The tests with Dryden's F-15B were designed to replicate the pressure environment the Shuttle encounters during the first minute after launch. No noticeable erosion of the insulation material was noted after the flight experiment at Dryden.
NASA Astrophysics Data System (ADS)
Bondarenko, J. A.; Fedorenko, M. A.; Pogonin, A. A.
2018-03-01
The loading and unloading units and grinding mills of raw devices have internal cone type or pipe screw perceive load of incoming and outgoing material. The main part of the support assembly is a pin. Mounting seats for the pipe screws cone have traces of deformation and work hardening, while they themselves have wear of pins and deformation of the inner and outer cylindrical working surface. In the mill body, there are constantly acting dynamic forces causing vibration, which are transmitted to the stud and inner accelerating elements. Under the influence of stress and vibration, the housing spigot is in the stress-compressed state and stretched vertically and horizontally. As a result, the insertion element is deformed and weakened in the fixture. A moving element appears in the gap leading to the fact that it drops lfeedstock and under the influence of variable loads it is destroyed, as well as the seating surfaces of the insert pin member.
Choral Intonation: More than Meets the Ear.
ERIC Educational Resources Information Center
Powell, Steven
1991-01-01
Considers some ways in which choral directors can help choristers improve intonation. Suggests music exercises for vertical and horizontal intonation and unified vowel formation. Also discusses physical factors, including tension, poor posture, and poor breath management, that influence how well a chorus stays in tune. Outlines relaxation and…
Hybrid Residual Flexibility/Mass-Additive Method for Structural Dynamic Testing
NASA Technical Reports Server (NTRS)
Tinker, M. L.
2003-01-01
A large fixture was designed and constructed for modal vibration testing of International Space Station elements. This fixed-base test fixture, which weighs thousands of pounds and is anchored to a massive concrete floor, initially utilized spherical bearings and pendulum mechanisms to simulate Shuttle orbiter boundary constraints for launch of the hardware. Many difficulties were encountered during a checkout test of the common module prototype structure, mainly due to undesirable friction and excessive clearances in the test-article-to-fixture interface bearings. Measured mode shapes and frequencies were not representative of orbiter-constrained modes due to the friction and clearance effects in the bearings. As a result, a major redesign effort for the interface mechanisms was undertaken. The total cost of the fixture design, construction and checkout, and redesign was over $2 million. Because of the problems experienced with fixed-base testing, alternative free-suspension methods were studied, including the residual flexibility and mass-additive approaches. Free-suspension structural dynamics test methods utilize soft elastic bungee cords and overhead frame suspension systems that are less complex and much less expensive than fixed-base systems. The cost of free-suspension fixturing is on the order of tens of thousands of dollars as opposed to millions, for large fixed-base fixturing. In addition, free-suspension test configurations are portable, allowing modal tests to be done at sites without modal test facilities. For example, a mass-additive modal test of the ASTRO-1 Shuttle payload was done at the Kennedy Space Center launch site. In this Technical Memorandum, the mass-additive and residual flexibility test methods are described in detail. A discussion of a hybrid approach that combines the best characteristics of each method follows and is the focus of the study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stredde, H.; /Fermilab
1998-05-27
A lifting fixture has been designed to handle the Samus counters. These counters are being removed from the D-zero area and will be transported off site for further use at another facility. This fixture is designed specifically for this particular application and will be transferred along with the counters. The future use of these counters may entail installation at a facility without access to a crane and therefore a lift fixture suitable for both crane and/or fork lift usage has been created The counters weigh approximately 3000 lbs. and have threaded rods extended through the counter at the top comersmore » for lifting. When these counters were first handled/installed these rods were used in conjunction with appropriate slings and handled by crane. The rods are secured with nuts tightened against the face of the counter. The rod thread is M16 x 2({approx}.625-inch dia.) and extends 2-inch (on average) from the face of the counter. It is this cantilevered rod that the lift fixture engages with 'C' style plates at the four top comers. The strongback portion of the lift fixture is a steel rectangular tube 8-inch (vertical) x 4-inch x .25-inch wall, 130-inch long. 1.5-inch square bars are welded perpendicular to the long axis of the rectangular tube at the appropriate lift points and the 'C' plates are fastened to these bars with 3/4-10 high strength bolts -grade 8. Two short channel sections are positioned-welded-to the bottom of the rectangular tube on 40 feet centers, which are used as locators for fork lift tines. On the top are lifting eyes for sling/crane usage and are rated at 3500 lbs. safe working load each - vertical lift only.« less
NASA Technical Reports Server (NTRS)
1969-01-01
Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.
Portable fixture facilitates pressure testing of instrumentation fittings
NASA Technical Reports Server (NTRS)
Olson, G. A.
1967-01-01
Portable fixture facilitates pressure testing to detect possible leaks in instrumentation fittings mounted on tank bulkheads. It uses a vacuum cup which seals a pressure regulator adapter around one side of the fitting to be pressure tested. Leakage is detected with a gas sniffer.
Energy conservation in two wheeler head tube welding fixture by modeling
NASA Astrophysics Data System (ADS)
Kamalanathan, S.; Guruprasad, B.; Elango, A.
2018-05-01
Energy conservation in automotive industry plays a significant role to increase the productivity which reduces the Men, Material, and Machinery. The Automotive industry sector is one of the major sector which works in two or more times of loading of work pieces in welding fixture. It consumes more energy. This project focuses on reduce the energy consumption by applying single time loading of work pieces with minimum number of labours, machine and reduces scrap. Welding fixtures are designed for the components which are difficult to weld in normal way or without any holding unit. The fixture is to be designed for the two wheeler head tube assembly which is to be welded with its companion for its application. It is demonstrated by modelling in Uni-graphics Software and FEA analysis will be done by ANSYS and experimentally products are tested and execute in industry. A code of practice suggested establishing acceptable standard for energy used in Automotive industry.
Effect of target-fixture geometry on shock-wave compacted copper powders
NASA Astrophysics Data System (ADS)
Kim, Wooyeol; Ahn, Dong-Hyun; Yoon, Jae Ik; Park, Lee Ju; Kim, Hyoung Seop
2018-01-01
In shock compaction with a single gas gun system, a target fixture is used to safely recover a powder compact processed by shock-wave dynamic impact. However, no standard fixture geometry exists, and its effect on the processed compact is not well studied. In this study, two types of fixture are used for the dynamic compaction of hydrogen-reduced copper powders, and the mechanical properties and microstructures are investigated using the Vickers microhardness test and electron backscatter diffraction, respectively. With the assistance of finite element method simulations, we analyze several shock parameters that are experimentally hard to control. The results of the simulations indicate that the target geometry clearly affects the characteristics of incident and reflected shock waves. The hardness distribution and the microstructure of the compacts also show their dependence on the geometry. With the results of the simulations and the experiment, it is concluded that the target geometry affects the shock wave propagation and wave interaction in the specimen.
Closeup of F-15B Flight Test Fixture (FTF) with X-33 Thermal Protection Systems (TPS)
NASA Technical Reports Server (NTRS)
1998-01-01
A close up of the Flight Test Fixture II, mounted on the underside of the F-15B Aerodynamic Flight Facility aircraft. The Thermal Protection System (TPS)samples, which included metallic Inconel tiles, soft Advanced Flexible Reusable Surface Insulation tiles, and sealing materials, were attached to the forward-left side position of the test fixture. In-flight video from the aircraft's on-board video system, as well as chase aircraft photos and video footage, documented the condition of the TPS during flights. Surface pressures over the TPS was measured by thermocouples contained in instrumentation 'islands,' to document shear and shock loads.
Heat transfer assembly for a fluorescent lamp and fixture
Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.
1992-12-29
In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.
NASA Technical Reports Server (NTRS)
Burke, Christopher S.
2011-01-01
Wire-testing issues, such as the gripping strains imposed on the wire, play a critical role in obtaining clean data. In a standard test frame fitted with flat wedge grips, the gripping action alone creates stresses on the wire specimen that cause the wire to fail at the grip location. A new test frame, which is outfitted with a vacuum chamber, negated the use of any conventional commercially available wire test fixtures, as only 7 in. (17.8 cm) existed between the grip faces. An innovative grip fixture was designed to test thin gauge wire for a variety of applications in an existing Instron test frame outfitted with a vacuum chamber.
Closeup of F-15B Flight Test Fixture (FTF) with X-33 Thermal Protection Systems (TPS)
1998-05-14
A close up of the Flight Test Fixture II, mounted on the underside of the F-15B Aerodynamic Flight Facility aircraft. The Thermal Protection System (TPS) samples, which included metallic Inconel tiles, soft Advanced Flexible Reusable Surface Insulation tiles, and sealing materials, were attached to the forward-left side position of the test fixture. In-flight video from the aircraft's on-board video system, as well as chase aircraft photos and video footage, documented the condition of the TPS during flights. Surface pressures over the TPS was measured by thermocouples contained in instrumentation "islands," to document shear and shock loads.
Thermal resilient multiple jaw braze fixture
Ney, Robert; Perrone, Alex J.
1995-07-11
A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle.
Exploring Outcome Measures for Exercise Intervention in People with Parkinson's Disease
King, L. A.; Salarian, A.; Mancini, M.; Priest, K. C.; Nutt, J.; Serdar, A.; Wilhelm, J.; Schlimgen, J.; Smith, M.; Horak, F. B.
2013-01-01
Background. It is widely believed that exercise improves mobility in people with Parkinson's disease (PD). However, it is difficult to determine whether a specific type of exercise is the most effective. The purpose of this study was to determine which outcome measures were sensitive to exercise intervention and to explore the effects of two different exercise programs for improving mobility in patients with PD. Methods. Participants were randomized into either the Agility Boot Camp (ABC) or treadmill training; 4x/week for 4 weeks. Outcome measures were grouped by the International Classification of Function/Disability (ICF). To determine the responsiveness to exercise, we calculated the standardized response means. t-tests were used to compare the relative benefits of each exercise program. Results. Four of five variables at the structure/function level changed after exercise: turn duration (P = 0.03), stride velocity (P = 0.001), peak arm speed (P = 0.001), and horizontal trunk ROM during gait (P = 0.02). Most measures improved similarly for both interventions. The only variable that detected a difference between groups was postural sway in ABC group (F = 4.95; P = 0.03). Conclusion. Outcome measures at ICF body structure/function level were most effective at detecting change after exercise and revealing differences in improvement between interventions. PMID:23738230
Positioning and locking apparatus
Hayward, Milton L.; Harper, William H.
1987-01-01
A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.
Positioning and locking apparatus
Hayward, M.L.; Harper, W.H.
1985-06-19
A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.
30 CFR 57.3203 - Rock fixtures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the ground in an area with similar strata, opening dimensions and ground stresses in any mine; or (2... has similar strata, opening dimensions, and ground stresses as the area where the fixtures are..., and the last bolt installed in each work area during the shift shall be accurately determined...
30 CFR 57.3203 - Rock fixtures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the ground in an area with similar strata, opening dimensions and ground stresses in any mine; or (2... has similar strata, opening dimensions, and ground stresses as the area where the fixtures are..., and the last bolt installed in each work area during the shift shall be accurately determined...
24 CFR 3280.607 - Plumbing fixtures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... less than 11/2 inches for sinks of two or more compartments, dishwashers, clothes washing machines... of Test for Safety Glazing Materials Used in Buildings, ANSI Z97.1-1984. (iv) Prefabricated plumbing fixtures shall be approved or listed. (4) Dishwashing machines. (i) A dishwashing machine shall not be...
24 CFR 3280.607 - Plumbing fixtures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... less than 11/2 inches for sinks of two or more compartments, dishwashers, clothes washing machines... of Test for Safety Glazing Materials Used in Buildings, ANSI Z97.1-1984. (iv) Prefabricated plumbing fixtures shall be approved or listed. (4) Dishwashing machines. (i) A dishwashing machine shall not be...
24 CFR 3280.607 - Plumbing fixtures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... less than 11/2 inches for sinks of two or more compartments, dishwashers, clothes washing machines... of Test for Safety Glazing Materials Used in Buildings, ANSI Z97.1-1984. (iv) Prefabricated plumbing fixtures shall be approved or listed. (4) Dishwashing machines. (i) A dishwashing machine shall not be...
24 CFR 3280.607 - Plumbing fixtures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... less than 11/2 inches for sinks of two or more compartments, dishwashers, clothes washing machines... of Test for Safety Glazing Materials Used in Buildings, ANSI Z97.1-1984. (iv) Prefabricated plumbing fixtures shall be approved or listed. (4) Dishwashing machines. (i) A dishwashing machine shall not be...
Ibrahim, Marize; Muanza, Thierry; Smirnow, Nadia; Sateren, Warren; Fournier, Beatrice; Kavan, Petr; Palumbo, Michael; Dalfen, Richard; Dalzell, Mary-Ann
2018-02-01
The diagnosis of breast cancer in young women (aged 18-45 years) has been increasing. Women are commonly left coping with treatment-related disabilities of the upper limb that can persist for > 2 years postoperatively. A total of 59 young breast cancer patients (29 in the intervention group and 30 in the control group) participated in a pilot prospective randomized controlled trial to determine whether a 12-week postradiation exercise program would improve long-term arm mobility, pain, and handgrip strength. During an 18-month period, range of motion, handgrip strength, and pain with shoulder movements were evaluated at 6 points. Although the differences were not statistically significant, external rotation and horizontal abduction of the shoulder improved in the intervention group immediately after the exercise intervention (3 months) and showed a trend toward less pain on movement. However, at 18 months after radiation the control and intervention groups both retained a residual loss of range and persistent pain with movement. Radiation to the axilla and/or chest wall yielded long-term (18 months) limitations in flexion and horizontal abduction compared with hypofractionation, which resulted in greater flexion and external rotation at 18 months. The median grip strength of the study participants corresponded to the 10th percentile of healthy aged-matched white women. The exercise intervention timed shortly after radiation improved short-term shoulder mobility and pain; however, these gains were not sustained at 18 months after radiation. Copyright © 2017 Elsevier Inc. All rights reserved.
Capacitor discharge process for welding braided cable
Wilson, Rick D.
1995-01-01
A capacitor discharge process for welding a braided cable formed from a plurality of individual cable strands to a solid metallic electrically conductive member comprises the steps of: (a) preparing the electrically conductive member for welding by bevelling one of its end portions while leaving an ignition projection extending outwardly from the apex of the bevel; (b) clamping the electrically conductive member in a cathode fixture; (c) connecting the electrically conductive member clamped in the cathode fixture to a capacitor bank capable of being charged to a preselected voltage value; (d) preparing the braided cable for welding by wrapping one of its end portions with a metallic sheet to form a retaining ring operable to maintain the individual strands of the braided cable in fixed position within the retaining ring; (e) clamping the braided cable and the retaining ring as a unit in an anode fixture so that the wrapped end portion of the braided cable faces the ignition projection of the electrically conductive member; and (f) moving the cathode fixture towards the anode fixture until the ignition projection of the electrically conductive member contacts the end portion of the braided cable thereby allowing the capacitor bank to discharge through the electrically conductive member and through the braided cable and causing the electrically conductive member to be welded to the braided cable via capacitor discharge action.
10 CFR 429.54 - Metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Metal halide lamp ballasts and fixtures. 429.54 Section 429.54 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR... and tested to ensure that: (i) Any represented value of estimated energy efficiency calculated as the...
10 CFR 429.54 - Metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Metal halide lamp ballasts and fixtures. 429.54 Section 429.54 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR... and tested to ensure that: (i) Any represented value of estimated energy efficiency calculated as the...
10 CFR 429.54 - Metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Metal halide lamp ballasts and fixtures. 429.54 Section 429.54 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR... and tested to ensure that: (i) Any represented value of estimated energy efficiency calculated as the...
Positioning and locking apparatus
Hayward, M.L.; Harper, W.H.
1987-06-30
A positioning and locking apparatus are disclosed including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member. 6 figs.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., together with such movable or special fixtures and necessary adaptations as are authorized by 38 U.S.C... improvements thereon and which is in keeping with the locality; and special fixtures and necessary adaptations....S.C. chapter 21 and this subpart. (Authority: 38 U.S.C. 501, 2101) Temporary residence adaptations...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., together with such movable or special fixtures and necessary adaptations as are authorized by 38 U.S.C... improvements thereon and which is in keeping with the locality; and special fixtures and necessary adaptations....S.C. chapter 21 and this subpart. (Authority: 38 U.S.C. 501, 2101) Temporary residence adaptations...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., together with such movable or special fixtures and necessary adaptations as are authorized by 38 U.S.C... improvements thereon and which is in keeping with the locality; and special fixtures and necessary adaptations....S.C. chapter 21 and this subpart. (Authority: 38 U.S.C. 501, 2101) Temporary residence adaptations...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., together with such movable or special fixtures and necessary adaptations as are authorized by 38 U.S.C... improvements thereon and which is in keeping with the locality; and special fixtures and necessary adaptations....S.C. chapter 21 and this subpart. (Authority: 38 U.S.C. 501, 2101) Temporary residence adaptations...
Fixture For Sampling Volatile Materials In Containers
NASA Technical Reports Server (NTRS)
Melton, Donald; Pratz, Earl Howard
1995-01-01
Fixture based on T-connector enables mass-spectrometric analysis of volatile contents of cylindrical containers without exposing contents to ambient conditions. Used to sample volatile contents of pressurized containers, contents of such enclosed processing systems as gas-phase reactors, gases in automotive emission systems, and gas in hostile environments.
24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Outdoor outlets, fixtures, air-conditioning equipment, etc. 3280.813 Section 3280.813 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF ASSISTANT SECRETARY FOR HOUSING-FEDERAL HOUSING...
Plumbing and Heating Curriculum.
ERIC Educational Resources Information Center
EASTCONN Regional Educational Services Center, North Windham, CT.
Theory and experience in the following areas are included in this plumbing curriculum: (1) plumbing fixtures and heating; (2) city water service; (3) fixture roughing; (4) venting; and (5) solar heating systems. The plumbing program manual includes the following sections: (1) general objectives for grades 10, 11, and 12; (2) a list of 33 major…
Carling, C; Le Gall, F; Dupont, G
2012-01-01
In this study, the effects of a prolonged period of fixture congestion (8 successive official matches in 26 days) on physical performance and injury risk and severity in a professional soccer team were investigated. Computerised motion-analysis was used to analyse the overall distance covered and that run at light- (0.0-11.0 km·h - 1); low- (11.1-14.0 km·h - 1); moderate- (14.1-19.7 km·h - 1) and high-intensities (≥19.8 km·h - 1) for the team as a whole. Distances were measured in metres per minute. Information on match injuries was recorded prospectively. The overall distance covered varied across successive matches (p<0.001) as more distance was run in games 4 and 7 compared to 2 and 3, respectively (126.6 ± 12.3 m·min - 1 and 125.0 ± 13.2 m·min - 1 vs. 116.0 ± 8.0 m·min - 1 and 115.5 ± 11.0 m·min - 1). Distance run in light-intensity exercise also varied (p<0.001) as more distance was covered in game 4 vs. 1, 2, 3, 5 and 6 (75.5 ± 3.8 m·min - 1 vs. 70.6 ± 2.4 m·min - 1, 71.8 ± 3.4 m·min - 1, 69.3 ± 2.6 m·min - 1, 71.5 ± 3.1 m·min - 1, and 70.3 ± 2.8 m·min - 1) and in game 8 vs. game 3 (73.1 ± 3.8 vs. 69.3 ± 2.6 m·min - 1), respectively. When comparing match halves, there were no differences across games in overall or high-intensity distance covered and performance in these measures was similar for matches played before, during and after this period. Globally, no difference over the 8 games combined was observed between the reference team and opponents in any of the performance measures whereas the overall distance covered and that in low- (both p<0.001) and high-intensity running (p=0.040) differed in individual games. The incidence of match injury during the congested fixture period was similar to rates reported outside this period but the mean lay-off duration of injuries was substantially shorter during the former (p<0.05). In summary, while the overall distance run and that covered at lower intensities varied across games, high-intensity running performance and injury risk were generally unaffected during a prolonged period of fixture congestion. These results might be linked to squad rotation and post-match recovery strategies in place at the present club. © Georg Thieme Verlag KG Stuttgart · New York.
Effects of oral glucose on exercise thermoregulation in men after water immersion
NASA Technical Reports Server (NTRS)
Dearborn, Alan S.; Ertl, Andrew C.; Greenleaf, John E.; Barnes, Paul R.; Jackson, Catherine G. R.; Breckler, Jennifer L.
1994-01-01
To test the hypothesis elevated blood glucose would attenuate the rise in exercise rectal temperature, six men age 35 plus or minus S.D. 7 years participated in each of three trials by 4-hr water immersion to the neck: (1) 2.0 g/kg body wt of oral glucose (33.8 percent wt./vol.) was consumed followed by 80 min controlled rest (Glu/Rest), and 70 min horizontal supine cycle exercise at 62.8 percent plus or minus S.E. 0.5 percent (1.97 plus or minus 0.02 L/min) of peak O2 uptake followed by 10 min recovery (2) with (Glu/Ex) and (3) without prior flucose (No Glu/Ex). Blood samples were taken at -25, 0, 15, 45, and 68 min of exercise and after plus 10 min of recovery for measurement of hemoglobin, hematocrit, and blood glucose. Both mean skin (T sub sk) (from six sites) and rectal temperatures (T sub re) were monitored continuously. Sweat rate was measured by resistanc hygrometry. The mean of delta PV for the exercise trials was -12.2 plus or minus 2.1 percent. Mean blood glucose for the Glu/Ex trial was higher than that of the No Glu/Ex trial was (108.4 equal or minus 3.9 and 85.6 plus or minus 1.6 mg/dl, respectively, P less than 0.05. At the end of exercise T(sub sk) for the Glu/Ex trial was lower than for No Glu/Ex(32.0 plus or minus 0.3 and 32.4 equals or minus 0.2 C, respectively, P less than 0.05); T(sub re) for the Glu/Ex trial was lower than for No Glu/Es (38.22 plus or minus 0.17 and 38.60 plus or minus 0.11 C, respectively, P less than 0.05); and forearm sweat rate for the Glu/Ex trial (0.34 plus or minus 0.04 and 0.43 plus or minus g/sq cm, respectively, P less than 0.05). These data suggest that elevation of blood glucose prior to horizontal exercise following hypohydration attenuates the increase in body temperature without altering heat production or exercise hypovolemia.
Thermal resilient multiple jaw braze fixture
Ney, R.; Perrone, A.J.
1995-07-11
A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle. 9 figs.
Daylight control system device and method
Paton, John Douglas
2007-03-13
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system, device and method
Paton, John Douglas
2012-08-28
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system device and method
Paton, John Douglas
2009-12-01
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Microfluidic hubs, systems, and methods for interface fluidic modules
Bartsch, Michael S; Claudnic, Mark R; Kim, Hanyoup; Patel, Kamlesh D; Renzi, Ronald F; Van De Vreugde, James L
2015-01-27
Embodiments of microfluidic hubs and systems are described that may be used to connect fluidic modules. A space between surfaces may be set by fixtures described herein. In some examples a fixture may set substrate-to-substrate spacing based on a distance between registration surfaces on which the respective substrates rest. Fluidic interfaces are described, including examples where fluid conduits (e.g. capillaries) extend into the fixture to the space between surfaces. Droplets of fluid may be introduced to and/or removed from microfluidic hubs described herein, and fluid actuators may be used to move droplets within the space between surfaces. Continuous flow modules may be integrated with the hubs in some examples.
Effects of Kinesio taping and exercise on forward head posture.
Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi
2017-01-01
Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS (CONTINUED) TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and... Applicability; description of the wood furniture and fixture production without water wash spray booth(s) or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS (CONTINUED) TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and... Applicability; description of the wood furniture and fixture production without water wash spray booth(s) or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS (CONTINUED) TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and... Applicability; description of the wood furniture and fixture production without water wash spray booth(s) or...
30 CFR 56.3203 - Rock fixtures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... similar strata, opening dimensions and ground stresses in any mine; or (2) Have been tested and shown to... dimensions, and ground stresses as the area where the fixtures are expected to be used. During the test... the rock. (2) The torque of the first bolt, every tenth bolt, and the last bolt installed in each work...
30 CFR 56.3203 - Rock fixtures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... similar strata, opening dimensions and ground stresses in any mine; or (2) Have been tested and shown to... dimensions, and ground stresses as the area where the fixtures are expected to be used. During the test... the rock. (2) The torque of the first bolt, every tenth bolt, and the last bolt installed in each work...
46 CFR 154.406 - Design loads for cargo tanks and fixtures: General.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Design loads for cargo tanks and fixtures: General. 154.406 Section 154.406 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Containment...
46 CFR 154.406 - Design loads for cargo tanks and fixtures: General.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Design loads for cargo tanks and fixtures: General. 154.406 Section 154.406 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Containment...
46 CFR 154.406 - Design loads for cargo tanks and fixtures: General.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Design loads for cargo tanks and fixtures: General. 154.406 Section 154.406 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Containment...
Wood usage trends in the furniture and fixtures industry
H. N. Spelter; R. N. Stone; D. B. McKeever
1978-01-01
Trends of wood use in the furniture and fixtures industry are examined. Wood consumption statistics from the 1972 Census of Manufactures are used to update prior Forest Service surveys, and separate estimates are made for 1977 consumption. A methodology for making up-to-date estimates of wood usage is also presented.
Calculations of the Acceleration of Centrifugal Loading on Adherent Cells
NASA Astrophysics Data System (ADS)
Chen, Kang; Song, Yang; Liu, Qing; Zhang, Chunqiu
2017-07-01
Studies have shown that the morphology and function of living cells are greatly affected by the state of different high acceleration. Based on the centrifuge, we designed a centrifugal cell loading machine for the mechanical biology of cells under high acceleration loading. For the machine, the feasibility of the experiment was studied by means of constant acceleration or variable acceleration loading in the Petri dish fixture and/or culture flask. Here we analyzed the distribution of the acceleration of the cells with the change of position and size of the culturing device quantitatively. It is obtained that Petri dish fixture and/or culture flask can be used for constant acceleration loading by experiments; the centripetal acceleration of the adherent cells increases with the increase of the distance between the rotor center of the centrifuge and the fixture of the Petri dish and the size of the fixture. It achieves the idea that the general biology laboratory can conduct the study of mechanical biology at high acceleration. It also provides a basis for more accurate study of the law of high acceleration on mechanobiology of cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishimura, A.
2008-03-03
A short beam test is useful to evaluate interlaminar shear strength of glass fiber reinforced plastics, especially for material selection. However, effect of test fixture configuration on interlaminar shear strength has not been clarified. This paper describes dependence of fracture mode and interlaminar shear strength on the fixture radius using the same materials and procedure. In addition, global understanding of the role of the fixture is discussed. When small loading nose and supports are used for the tests, bending fracture or translaminar fracture happens and the interlaminar shear strength would become smaller. By adopting the large radius loading nose andmore » supports (6 mm radius is recommended), it is newly recognized that some stress concentration is able to be reduced, and the interlaminar fracture tends to occur and the other fracture modes will be suppressed. The interlaminar shear strength of 2.5 mm thick GFRP plate of G-10CR is evaluated as 130-150 MPa at 77 K.« less
Effect of thread size on the implant neck area: preliminary results at 1 year of function.
Kang, Young-Il; Lee, Dong-Won; Park, Kwang-Ho; Moon, Ik-Sang
2012-10-01
To evaluate and compare the effect of the coronal thread size on the marginal bone loss around the fixtures, when both implants were provided with threads to the top of fixture. Two groups of implants, one with a macro-thread to the top of the fixture (A) and the other with a micro-thread to the top of the fixture (B), were placed adjacent to each other in the partially edentulous areas of 20 patients. Bone loss around each implant was analyzed after 1 year of functional loading. The bone losses after loading were compared using Wilcoxon's signed-rank test. The mean marginal bone losses (A, 0.154 ± 0.144 mm; B, 0.125 ± 0.136 mm) were not statistically significant between the two groups (P = 0.669). There was no significant difference between implant with macro- and micro-neck thread in terms of marginal bone loss after 1 year of loading. © 2011 John Wiley & Sons A/S.
Tool holder for preparation and inspection of a radiused edge cutting tool
Asmanes, Charles
1979-01-01
A tool holding fixture is provided for removably holding a radiused edge cutting tool in a tool edge lapping apparatus. The fixture allows the operator to preset the lapping radius and angle before the tool holder is placed in the fixture and the holder may be removed from the lapping apparatus to inspect the tool and simply replaced in the fixture to continue lapping in accordance with a precise alignment without realignment of the tool relative to the lap. The tool holder includes a pair of self aligning bearings in the form of precision formed steel balls connected together by a rigid shaft. The tool is held by an arm extending from the shaft and the balls set in fixed position bearing cups and the holder is oscillated back and forth about a fixed axis of rotation to lap the tool radius by means of a reversibly driven belt-pulley arrangement coupled to the shaft between the bearings. To temporarily remove the holder, the drive belt is slipped over the rearward end of the holder and the holder is lifted out of the bearing cups.
A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components
NASA Technical Reports Server (NTRS)
Mejia, M.; Creason, A. S.; Toncich, S. S.; Ebihara, B. T.; Miranda, F. A.
1996-01-01
The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.
NASA Technical Reports Server (NTRS)
Ellis, J. R.; Sandlass, G. S.; Bayyari, M.
2001-01-01
A design study was undertaken to investigate the feasibility of using simple specimen designs and reusable fixturing for in-plane biaxial tests planned for advanced aeropropulsion materials. Materials of interest in this work include: advanced metallics, polymeric matrix composites, metal and intermetallic matrix composites, and ceramic matrix composites. Early experience with advanced metallics showed that the cruciform specimen design typically used in this type of testing was impractical for these materials, primarily because of concerns regarding complexity and cost. The objective of this research was to develop specimen designs, fixturing, and procedures which would allow in-plane biaxial tests to be conducted on a wide range of aeropropulsion materials while at the same time keeping costs within acceptable limits. With this goal in mind. a conceptual design was developed centered on a specimen incorporating a relatively simple arrangement of slots and fingers for attachment and loading purposes. The ANSYS finite element code was used to demonstrate the feasibility of the approach and also to develop a number of optimized specimen designs. The same computer code was used to develop the reusable fixturing needed to position and grip the specimens in the load frame. The design adopted uses an assembly of slotted fingers which can be reconfigured as necessary to obtain optimum biaxial stress states in the specimen gage area. Most recently, prototype fixturing was manufactured and is being evaluated over a range of uniaxial and biaxial loading conditions.
Mekjavic, Igor B; Golja, Petra; Tipton, Michael J; Eiken, Ola
2005-10-01
The present study evaluated the effect of 35 days of experimental horizontal bed-rest on exercise and immersion thermoregulatory function. Fifteen healthy male volunteers were assigned to either a Control (n = 5) or Bed-rest (n = 10) group. Thermoregulatory function was evaluated during a 30-min bout of submaximal exercise on a cycle ergometer, followed immediately by a 100-min immersion in 28 degrees C water. For the Bed-rest group, exercise and immersion thermoregulatory responses observed post-bed-rest were compared with those after a 5 week supervised active recovery period. In both trials, the absolute work load during the exercise portion of the test was identical. During the exercise and immersion, we recorded skin temperature, rectal temperature, the difference in temperature between the forearm and third digit of the right hand (DeltaT(forearm-fingertip))--an index of skin blood flow, sweating rate from the forehead, oxygen uptake and heart rate at minute intervals. Subjects provided ratings of temperature perception and thermal comfort at 5-min intervals. Exercise thermoregulatory responses after bed-rest and recovery were similar. Subjective ratings of temperature perception and thermal comfort during immersion indicated that subjects perceived similar combinations of Tsk and Tre to be warmer and thermally less uncomfortable after bed-rest. The average (SD) exercise-induced increase in Tre relative to resting values was not significantly different between the Post-bed-rest (0.4 (0.2) degrees C) and Recovery (0.5 (0.2) degrees C) trials. During the post-exercise immersion, the decrease in Tre, relative to resting values, was significantly (P < 0.05) greater in the Post-bed-rest trial (0.9 (0.5) degrees C) than after recovery (0.4 (0.3) degrees C). DeltaT(forearm-fingertip) was 5.2 (0.9) degrees C and 5.8 (1.0) degrees C at the end of the post-bed-rest and recovery immersions, respectively. The gain of the shivering response (increase in VO(2) relative to the decrease in Tre; VO(2)/Tre) was 1.19 l min(-1) degrees C(-1) in the Recovery trial, and was significantly attenuated to 0.51 l min(-1) degrees C(-1) in the Post-bed-rest trial. The greater cooling rate observed in the post-bed-rest trial is attributed to the greater heat loss and reduced heat production. The former is the result of attenuated cold-induced vasoconstriction and enhanced sweating rate, and the latter a result of a lower shivering VO(2) response.
Effect of Gravity on Robot-Assisted Motor Training After Chronic Stroke: A Randomized Trial
Conroy, Susan S.; Whitall, Jill; Dipietro, Laura; Jones-Lush, Lauren M.; Zhan, Min; Finley, Margaret A.; Wittenberg, George F.; Krebs, Hermano I.; Bever, Christopher T.
2015-01-01
Objectives To determine the efficacy of 2 distinct 6-week robot-assisted reaching programs compared with an intensive conventional arm exercise program (ICAE) for chronic, stroke-related upper-extremity (UE) impairment. To examine whether the addition of robot-assisted training out of the horizontal plane leads to improved outcomes. Design Randomized controlled trial, single-blinded, with 12-week follow-up. Setting Research setting in a large medical center. Participants Adults (N=62) with chronic, stroke-related arm weakness stratified by impairment severity using baseline UE motor assessments. Interventions Sixty minutes, 3 times a week for 6 weeks of robot-assisted planar reaching (gravity compensated), combined planar with vertical robot-assisted reaching, or intensive conventional arm exercise program. Main Outcome Measure UE Fugl-Meyer Assessment (FMA) mean change from baseline to final training. Results All groups showed modest gains in the FMA from baseline to final with no significant between group differences. Most change occurred in the planar robot group (mean change ± SD, 2.94± 0.77; 95% confidence interval [CI], 1.40 – 4.47). Participants with greater motor impairment (n=41) demonstrated a larger difference in response (mean change ± SD, 2.29±0.72; 95% CI, 0.85–3.72) for planar robot-assisted exercise compared with the intensive conventional arm exercise program (mean change ± SD, 0.43±0.72; 95% CI, −1.00 to 1.86). Conclusions Chronic UE deficits because of stroke are responsive to intensive motor task training. However, training outside the horizontal plane in a gravity present environment using a combination of vertical with planar robots was not superior to training with the planar robot alone. PMID:21849168
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS (CONTINUED) TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and... Applicability; description of the wood furniture and fixture production with water wash spray booth(s) or with...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS (CONTINUED) TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and... Applicability; description of the wood furniture and fixture production with water wash spray booth(s) or with...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Applicability; description of the wood... GUIDELINES AND STANDARDS (CONTINUED) TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture and... Applicability; description of the wood furniture and fixture production with water wash spray booth(s) or with...
Holding fixture for metallographic mount polishing
Barth, Clyde H.; Cramer, Charles E.
1997-01-01
A fixture for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface.
Leveraging Lighting for Energy Savings: GSA Northwest/Artic Region
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-01-01
Case study describes how the Northwest/Arctic Region branch of the General Services Administration (GSA) improved safety and energy efficiency in its Fairbanks Federal Building parking garage used by federal employees, U.S. Marshals, and the District Court. A 74% savings was realized by replacing 220 high-pressure sodium fixtures with 220 light-emitting diode fixtures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... fixtures. Do not place insulation over such fixtures so as to entrap heat. Also keep this insulation away... SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CELLULOSE INSULATION § 1404.4 Requirements to... insulation shall give notification of performance and technical data related to performance and safety (1) to...
Code of Federal Regulations, 2014 CFR
2014-01-01
... fixtures. Do not place insulation over such fixtures so as to entrap heat. Also keep this insulation away... SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CELLULOSE INSULATION § 1404.4 Requirements to... insulation shall give notification of performance and technical data related to performance and safety (1) to...
Code of Federal Regulations, 2010 CFR
2010-01-01
... fixtures. Do not place insulation over such fixtures so as to entrap heat. Also keep this insulation away... SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CELLULOSE INSULATION § 1404.4 Requirements to... insulation shall give notification of performance and technical data related to performance and safety (1) to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... fixtures. Do not place insulation over such fixtures so as to entrap heat. Also keep this insulation away... SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CELLULOSE INSULATION § 1404.4 Requirements to... insulation shall give notification of performance and technical data related to performance and safety (1) to...
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
These military-developed curriculum materials consist of a course description, course chart, plan of instruction, lesson plans, study guides, and workbooks for use in training plumbing specialists IV and V. Covered in the course blocks are fixtures and appurtenances and utility equipment. Block IV on fixtures and appurtenances deals with…
24 CFR 3280.807 - Fixtures and appliances.
Code of Federal Regulations, 2011 CFR
2011-04-01
... is provided over a bathtub or in a shower stall, it must be of the enclosed and gasketed type, and be...-2005. (d) The switch for shower lighting fixtures and exhaust fans located over a tub or in a shower stall shall be located outside the tub shower space. (See § 3280.806(e).) (e) Any combustible wall or...
Spacecraft utensil/hand cleansing fixture
NASA Technical Reports Server (NTRS)
Jonkoniec, T. G.
1978-01-01
A fixture which provides a means for a crewman to perform, in zero gravity, laboratory utensil/tool cleansing and personal hygiene functions such as handwashing, shaving, body wash, and teeth brushing is described. A prototype unit developed incorporating design improvements resulting from breadboard tests in a one gravity and zero gravity environment demonstrated the capability of performing the different cleansing functions.
Preliminary eddy current modelling for the large angle magnetic suspension test fixture
NASA Technical Reports Server (NTRS)
Britcher, Colin
1994-01-01
This report presents some recent developments in the mathematical modeling of the Large Angle Magnetic Suspension Test Fixture (LAMSTF) at NASA Langley Research Center. It is shown that these effects are significant, but may be amenable to analysis, modeling and measurement. A theoretical framework is presented, together with a comparison of computed and experimental data.
2001-11-30
NASA Dryden's new in-house designed Propulsion Flight Test Fixture (PFTF), carried on an F-15B's centerline attachment point, underwent flight envelope expansion in order to verify its design and capabilities.
Root-sum-square structural strength verification approach
NASA Technical Reports Server (NTRS)
Lee, Henry M.
1994-01-01
Utilizing a proposed fixture design or some variation thereof, this report presents a verification approach to strength test space flight payload components, electronics boxes, mechanisms, lines, fittings, etc., which traditionally do not lend themselves to classical static loading. The fixture, through use of ordered Euler rotation angles derived herein, can be mounted on existing vibration shakers and can provide an innovative method of applying single axis flight load vectors. The versatile fixture effectively loads protoflight or prototype components in all three axes simultaneously by use of a sinusoidal burst of desired magnitude at less than one-third the first resonant frequency. Cost savings along with improved hardware confidence are shown. The end product is an efficient way to verify experiment hardware for both random vibration and strength.
Energy cost of isolated resistance exercises across low- to high-intensities
Garrido, Nuno Domingos; Vianna, Jeferson; Sousa, Ana Catarina; Alves, José Vilaça; Marques, Mário Cardoso
2017-01-01
This study aimed to estimate the energy cost across various intensities at eight popular resistance exercises: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 58 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. For each group, two exercises were randomly assigned and on different days, they performed four bouts of 5-min constant-intensity for each of the two assigned exercises: 12%, 16%, 20% and 24% 1-RM. Later, the subjects performed exhaustive bouts at 80% 1-RM in the same two exercises. The mean values of VO2 at the last 30s of exercise at 12, 16, 20 and 24% 1-RM bouts were plotted against relative intensity (% 1-RM) in a simple linear regression mode. The regressions were then used to predict O2 demand for the higher intensity (80% 1-RM). Energy cost rose linearly with exercise intensity in every exercise with the lowest mean values were found in biceps curl and the highest in half squat exercise (p<0.001). Half squat exercise presented significant (p<0.001) higher values of energy cost in all intensities, when compared with the remaining exercises. This study revealed that low-intensity resistance exercise provides energy cost comprised between 3 and 10 kcal∙min-1. Energy cost rose past 20 kcal∙min-1 at 80% 1-RM in leg exercise. In addition, at 80% 1-RM, it was found that upper body exercises are less anaerobic than lower-body exercises. PMID:28742112
ERIC Educational Resources Information Center
Burton, Erin Peters; Mattietti, G. K.
2011-01-01
In general, integration of spatial information can be difficult for students. To study students' spatial thinking and their self-efficacy of interpreting stratigraphic columns, we designed an exercise that asks college-level students to interpret problems on the principles of superposition, original horizontality and lateral continuity, and…
Holding fixture for metallographic mount polishing
Barth, C.H.; Cramer, C.E.
1997-12-30
A fixture is described for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface. 3 figs.
Camp Pendleton Saves 91% in Parking Lot Lighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-01-01
Case study describes how Camp Pendleton Marine Corps Base replaced high-pressure sodium (HPS) fixtures in one parking lot with high-efficiency induction fixtures for 91% savings in energy use and $5,700 in cost savings annually. This parking lot is estimated to have a simple payback of 2.9 years. Sitewide up-grades yielded annual savings of 1 million kWh.
Ahrens, Brandon R [Albuquerque, NM; Todd, Steven N [Rio Rancho, NM
2009-04-28
A precision laser aiming system comprises a disrupter tool, a reflector, and a laser fixture. The disrupter tool, the reflector and the laser fixture are configurable for iterative alignment and aiming toward an explosive device threat. The invention enables a disrupter to be quickly and accurately set up, aligned, and aimed in order to render safe or to disrupt a target from a standoff position.
Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures
Siminovitch, Michael J.
1992-01-01
In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.
Fixture for mounting small parts for processing
Foreman, Larry R.; Gomez, Veronica M.; Thomas, Michael H.
1990-01-01
A fixture for mounting small parts, such as fusion target spheres or microelectronic components. A glass stalk is drawn and truncated near its tip. The truncated end of the glass stalk is dipped into silicone rubber forming an extending streamer. After the rubber cures for approximately 24 hours, a small part is touched to the streamer, and will be held securely throughout processing.
Detecting Faults In High-Voltage Transformers
NASA Technical Reports Server (NTRS)
Blow, Raymond K.
1988-01-01
Simple fixture quickly shows whether high-voltage transformer has excessive voids in dielectric materials and whether high-voltage lead wires too close to transformer case. Fixture is "go/no-go" indicator; corona appears if transformer contains such faults. Nests in wire mesh supported by cap of clear epoxy. If transformer has defects, blue glow of corona appears in mesh and is seen through cap.
Small enterprises as important hardwood lumber consumers: Evidence from the current housing downturn
Urs Buehlmann; Matthew Bumgardner; Al Schuler; Jeff Crissey
2011-01-01
Housing fixtures (such as cabinets, flooring, moldings, and stairways) have become a major market for secondary wood products manufacturers in the United States and a major user of U.S. hardwood lumber. Thus, downturns in housing markets, with associated declines in the demand and price for fixtures, can pose significant challenges to the profitability of these...
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-06
CAPE CANAVERAL, Fla. – Technicians lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-06
CAPE CANAVERAL, Fla. – Technicians lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
Reducing Unsteady Loads on a Piggyback Miniature Submarine
NASA Technical Reports Server (NTRS)
Lin, John
2009-01-01
A small, simple fixture has been found to be highly effective in reducing destructive unsteady hydrodynamic loads on a miniature submarine that is attached in piggyback fashion to the top of a larger, nuclear-powered, host submarine. The fixture, denoted compact ramp, can be installed with minimal structural modification, and the use of it does not entail any change in submarine operations.
Advanced Computational Techniques for Power Tube Design.
1986-07-01
fixturing applications, in addition to the existing computer-aided engineering capabilities. o Helix TWT Manufacturing has Implemented a tooling and fixturing...illustrates the ajor features of this computer network. ) The backbone of our system is a Sytek Broadband Network (LAN) which Interconnects terminals and...automatic network analyzer (FANA) which electrically characterizes the slow-wave helices of traveling-wave tubes ( TWTs ) -- both for engineering design
A Guide to the Librarian's Responsibility in Achieving Quality in Lighting and Ventilation.
ERIC Educational Resources Information Center
Mason, Ellsworth
1967-01-01
Quality, not intensity, is the keystone to good library lighting. The single most important problem in lighting is glare caused by extremely intense centers of light. Multiple interfiling of light rays is a factor required in library lighting. A fixture that diffuses light well is basic when light emerges from the fixture. It scatters widely,…
Heat Bonding of Irradiated Ethylene Vinyl Acetate
NASA Technical Reports Server (NTRS)
Slack, D. H.
1986-01-01
Reliable method now available for joining parts of this difficult-tobond material. Heating fixture encircles ethylene vinyl acetate multiplesocket part, providing heat to it and to tubes inserted in it. Fixtures specially designed to match parts to be bonded. Tube-and-socket bonds made with this technique subjected to tensile tests. Bond strengths of 50 percent that of base material obtained consistently.
Fixture aids soldering of electronic components on circuit board
NASA Technical Reports Server (NTRS)
Ross, M. H.
1966-01-01
Spring clamp fixture holds small electronic components in a desired position while they are being soldered on a circuit board. The spring clamp is clipped on the edge of the circuit board and an adjustable spring-steel boom holds components against the board. The felt pad at the end of the boom is replaced with different attachments for other holding tasks.
Space ultra-vacuum facility and method of operation
NASA Technical Reports Server (NTRS)
Naumann, Robert J. (Inventor)
1986-01-01
A wake shield facility providing an ultrahigh vacuum level for space processing is described. The facility is in the shape of a truncated, hollow hemispherical section, one side of the shield convex and the other concave. The shield surface is preferably made of material that has low out-gassing characteristics such as stainless steel. A material sample supporting fixture in the form of a carousel is disposed on the convex side of the shield at its apex. Movable arms, also on the convex side, are connected by the shield in proximity to the carousel, the arms supporting processing fixtures, and providing for movement of the fixtures to predetermined locations required for producing interations with material samples. For MBE processes a vapor jet projects a stream of vaporized material onto a sample surface. The fixtures are oriented to face the surface of the sample being processed when in their extended position, and when not in use they are retractable to a storage position. The concave side of the shield has a support structure including metal struts connected to the shield, extending radially inward. The struts are joined to an end plate disposed parallel to the outer edge of the shield. This system eliminates outgassing contamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, Mark W.
2015-07-28
In a manufacturing process, a need is identified and a product is created to fill this need. While design and engineering of the final product is important, the tools and fixtures that aid in the creation of the final product are just as important, if not more so. Power supplies assembled at the TA-55 PF-5 have been designed by an excellent engineering team. The task in PF-5 now is to ensure that all steps of the assembly and manufacturing process can be completed safely, reliably, and in a quality repeatable manner. One of these process steps involves soldering fine wiresmore » to an electrical connector. During the process development phase, the method of soldering included placing the power supply in a vice in order to manipulate it into a position conducive to soldering. This method is unacceptable from a reliability, repeatability, and ergonomic standpoint. To combat these issues, a fixture was designed to replace the current method. To do so, a twelve step engineering design process was used to create the fixture that would provide a solution to a multitude of problems, and increase the safety and efficiency of production.« less
Additive Manufacturing of Tooling for Refrigeration Cabinet Foaming Processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Post, Brian K; Nuttall, David; Cukier, Michael
The primary objective of this project was to leverage the Big Area Additive Manufacturing (BAAM) process and materials into a long term, quick change tooling concept to drastically reduce product lead and development timelines and costs. Current refrigeration foam molds are complicated to manufacture involving casting several aluminum parts in an approximate shape, machining components of the molds and post fitting and shimming of the parts in an articulated fixture. The total process timeline can take over 6 months. The foaming process is slower than required for production, therefore multiple fixtures, 10 to 27, are required per refrigerator model. Moldsmore » are particular to a specific product configuration making mixed model assembly challenging for sequencing, mold changes or auto changeover features. The initial goal was to create a tool leveraging the ORNL materials and additive process to build a tool in 4 to 6 weeks or less. A secondary goal was to create common fixture cores and provide lightweight fixture sections that could be revised in a very short time to increase equipment flexibility reduce lead times, lower the barriers to first production trials, and reduce tooling costs.« less
Gadegaard, Jesper; Jensen, Thøger Kari; Jørgensen, Dennis Thykjær; Kristensen, Peter Kjær; Søndergaard, Thomas; Pedersen, Thomas Garm; Pedersen, Kjeld
2016-02-20
In the stage lighting and entertainment market, light engines (LEs) for lighting fixtures are often based on high-intensity discharge (HID) bulbs. Switching to LED-based light engines gives possibilities for fast switching, additive color mixing, a longer lifetime, and potentially, more energy-efficient systems. The lumen output of a single LED is still not sufficient to replace an HID source in high-output profile fixtures, but combining multiple LEDs can create an LE with a similar output, but with added complexity. This paper presents the results of modeling and testing such a light engine. Custom ray-tracing software was used to design a high-output red, green and blue LED-based light engine with twelve CBT-90 LEDs using a dual-reflector principle. The simulated optical system efficiency was 0.626 with a perfect (R=1) reflector coating for light delivered on a target surface through the entire optical system. A profile lighting fixture prototype was created, and provided an output of 6744 lumen and an efficiency of 0.412. The lower efficiency was mainly due to a non-optimal reflector coating, and the optimized design is expected to reach a significantly higher efficiency.
Alignment method for solar collector arrays
Driver, Jr., Richard B
2012-10-23
The present invention is directed to an improved method for establishing camera fixture location for aligning mirrors on a solar collector array (SCA) comprising multiple mirror modules. The method aligns the mirrors on a module by comparing the location of the receiver image in photographs with the predicted theoretical receiver image location. To accurately align an entire SCA, a common reference is used for all of the individual module images within the SCA. The improved method can use relative pixel location information in digital photographs along with alignment fixture inclinometer data to calculate relative locations of the fixture between modules. The absolute locations are determined by minimizing alignment asymmetry for the SCA. The method inherently aligns all of the mirrors in an SCA to the receiver, even with receiver position and module-to-module alignment errors.
Chang-Diaz holds PDGF for installation on the ISS P6 truss during STS-111 UF-2 EVA 1
2002-06-09
STS111-E-5034 (8 June 2002) --- Astronaut Franklin R. Chang-Diaz works with a grapple fixture during extravehicular activity (EVA) to perform work on the International Space Station (ISS). The first spacewalk of the STS-111 mission began with the installation of a Power and Data Grapple Fixture (PDGF) for the station's robotic arm on the complex's P6 truss. The PDGF will allow the robotic arm to grip the P6 truss for future station assembly operations. Astronauts Chang-Diaz and Philippe Perrin (with French Space Agency, CNES) went on to install the new fixture about halfway up the P6 truss, the vertical structure that currently supports the station's set of large U.S. solar arrays.
Spectroscopic temperature measurements in interior ballistic environments
NASA Astrophysics Data System (ADS)
Klingenberg, G.; Mach, H.
1984-11-01
Spectroscopic temperature measurements during the interior ballistic cycle of a 20 mm test fixture gun and inside the muzzle flash of a 7.62 mm rifle are described. The investigation yields information on temperature distribution in the burning propellant charge of the 20 mm test fixture and on radial temperature profiles in the 7.62 mm muzzle flash region. A technique to obtain temperature during the ignition and combustion within the 20 mm propellant charge is presented. Additional in-bore measurements by quartz windows mounted into bores along the barrel and emission-absorption measurements inside the muzzle flash of the 20 mm test fixture yield a complete temperature profile for the gun system. Spectroscopic infrared measurements inside the muzzle flash of a 7.62 mm rifle complete the investigation.
Patellar tendon load in different types of eccentric squats.
Frohm, A; Halvorsen, K; Thorstensson, A
2007-07-01
Differences in mechanical loading of the patellar tendon have been suggested as a reason for varying effects in rehabilitation of patellar tendinopathy using different eccentric squat exercises and devices. The aim was to characterize the magnitude and pattern of mechanical load at the knee and on the patellar tendon during four types of eccentric squat. Subjects performed squats with a submaximal free weight and with maximal effort in a device for eccentric overloading (Bromsman), on a decline board and horizontal surface. Kinematics was recorded with a motion-capture system, reaction forces with force plates, and electromyography from three leg muscles with surface electrodes. Inverse dynamics was used to calculate knee joint kinetics. Eccentric work, mean and peak patellar tendon force, and angle at peak force were greater (25-30%) for squats on decline board compared to horizontal surface with free weight, but not in Bromsman. Higher knee load forces (60-80%), but not work, were observed with Bromsman than free weight. Angular excursions at the knee and ankle were larger with decline board, particularly with free weight, and smaller in Bromsman than with free weight. Mean electromyography was greater on a decline board for gastrocnemius (13%) and vastus medialis (6%) with free weight, but in Bromsman only for gastrocnemius (7%). The results demonstrated clear differences in the biomechanical loading on the knee during different squat exercises. Quantification of such differences provides information that could be used to explain differences in rehabilitation effects as well as in designing more optimal rehabilitation exercises for patellar tendinopathy.
2011-01-01
Background The visual system plays an important role in maintaining balance. As a person ages, gait becomes slower and stride becomes shorter, especially in dimly lighted environments. Falls risk has been associated with reduced speed and increased gait variability. Methods Twenty-four older adults (half identified at risk for falls) experienced three lighting conditions: pathway illuminated by 1) general ceiling-mounted fixtures, 2) conventional plug-in night lights and 3) plug-in night lights supplemented by laser lines outlining the pathway. Gait measures were collected using the GAITRite© walkway system. Results Participants performed best under the general ceiling-mounted light system and worst under the night light alone. The pathway plus night lights increased gait velocity and reduced step length variability compared to the night lights alone in those at greater risk of falling. Conclusions Practically, when navigating in more challenging environments, such as in low-level ambient illumination, the addition of perceptual cues that define the horizontal walking plane can potentially reduce falls risks in older adults. PMID:21864387
Siminovitch, Michael J.; Page, Erik R.
2002-01-01
A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.
The Biomechanics of Exercise Countermeasures
NASA Technical Reports Server (NTRS)
Cavanagh, Peter R.; Arnold, Steven; Derr, Janice; Sharkey, Neil; Wu, Ge
1999-01-01
The Penn State Zero-gravity Simulator (PSZS) is a device developed by the Center for Locomotion Studies (CELOS) to enable ground studies of exercise countermeasures for the bone loss that has been shown to occur during long-term exposure to zero gravity (0G). The PSZS simulates 0G exercise by providing a suspension system that holds an individual in a horizontal (supine) position above the floor in order to enable exercise on a wall-mounted treadmill. Due to this orientation, exercise performed in the PSZS is free of the force of -ravity in the direction that would normally contribute to ground reaction forces. In order for movements to be more similar to those in 0G, a constant force suspension of each segment (equal to the segment weight) is provided regardless of limb position. During the preliminary development of the PSZS, CELOS researchers also designed an optional gravity-replacement simulation feature for the PSZS. This feature was a prototype tethering system that consisted of a spring tension system to pull an exercising individual toward the treadmill. The immediate application of the tethering system was to be the provision of gravity-replacement loading so that exercise in 0G- and 1G-loading conditions could be compared, and the PSZS could then be used to evaluate exercise countermeasures for bone loss during space flight. This tethering system would also be a model for the further refinement of gravity-replacement systems provided for astronaut usage while performing prescribed exercise countermeasures for bone loss during long-term space flights.
Key Terrain: Application to the Layers of Cyberspace
2017-03-01
in the early stages and exploration into better integrating military strategies could prove beneficial to those working to develop relevant and...200 words) The concept of key terrain is a common fixture in military strategy and tactics. The emergence of cyberspace, with characteristics unseen...concept of key terrain is a common fixture in military strategy and tactics. The emergence of cyberspace, with characteristics unseen in any
Architectural Survey of Pence Elementary School, Fort Leonard Wood, Missouri
2011-09-01
classroom floors , replacement acoustical tile drop ceilings, both original pendent ceiling light fixtures and replacement light fixtures, replacement wood...fixed pane transoms above, original door hardware, acoustical tile drop-ceiling, asbestos tile floor , and a metal radiator cover (photos 38-40...119). The corridors have acoustical tile drop-ceilings, concrete block walls, and asbestos tile floors (photo 44). There are several push-pin cork
Fixture for mounting small parts for processing
Foreman, L.R.; Gomez, V.M.; Thomas, M.H.
1990-05-29
A fixture for mounting small parts, such as fusion target spheres or microelectronic components is disclosed. A glass stalk is drawn and truncated near its tip. The truncated end of the glass stalk is dipped into silicone rubber forming an extending streamer. After the rubber cures for approximately 24 hours, a small part is touched to the streamer, and will be held securely throughout processing. 5 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhn, Joshua
2015-01-01
While working at Sandia National Laboratories as a graduate intern from September 2014 to January 2015, most of my time was spent on two projects. The first project involved designing a test fixture for circuit boards used in a recording device. The test fixture was needed to decrease test set up time. The second project was to use optimization techniques to determine the optimal G-Switch for given acceleration profiles.
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-06
CAPE CANAVERAL, Fla. – Technicians lower a special fixture around an Orion spacecraft inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-06
CAPE CANAVERAL, Fla. – Technicians lower a special fixture around an Orion spacecraft inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-06
CAPE CANAVERAL, Fla. – A special fixture stands in place around an Orion spacecraft inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures
Siminovitch, M.J.
1992-11-10
In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.
NASA's F-15B conducts a local Mach investigation flight over California's Mojave Desert.
2004-06-01
NASA's F-15B Research Testbed aircraft flew instrumentation in June 2004 called the Local Mach Investigation (LMI), designed to gather local airflow data for future research projects using the aircraft's Propulsion Flight Test Fixture (PFTF). The PFTF is the black rectangular fixture attached to the aircraft's belly. The LMI package was located in the orange device attached to the PFTF.
NASA's F-15B conducts a local Mach investigation flight over California's Mojave Desert.
2004-06-04
NASA's F-15B Research Testbed aircraft flew instrumentation in June 2004 called the Local Mach Investigation (LMI), designed to gather local airflow data for future research projects using the aircraft's Propulsion Flight Test Fixture (PFTF). The PFTF is the black rectangular fixture attached to the aircraft's belly. The LMI package was located in the orange device attached to the PFTF.
Scapular muscle activity in a variety of plyometric exercises.
Maenhout, Annelies; Benzoor, Maya; Werin, Maria; Cools, Ann
2016-04-01
Plyometric shoulder exercises are commonly used to progress from slow analytical strength training to more demanding high speed power training in the return to play phase after shoulder injury. The aim of this study was first, to investigate scapular muscle activity in plyometric exercises to support exercise selection in practice and second, to enhance understanding of how scapular muscles are recruited during the back and forth movement phase of these exercises. Thirty-two healthy subjects performed 10 plyometric exercises while surface EMG-activity of the scapular muscles (upper (UT), middle (MT) and lower trapezius (LT) and serratus anterior (SA)) was registered. A high speed camera tracked start and end of the back and forth movement. Mean scapular EMG activity during the 10 exercises ranged from 14.50% to 76.26%MVC for UT, from 15.19% to 96.55%MVC for MT, from 13.18% to 94.35%MVC for LT and from 13.50% to 98.50%MVC for SA. Anova for repeated measures showed significant differences in scapular muscle activity between exercises (p<0.001) and between the back and forth movement (p<0.001) within exercises. Plyometric shoulder exercises require moderate (31-60%MVC) to high (>60%MVC) scapular muscle activity. Highest MT/LT activity was present in prone plyometric external rotation and flexion. Highest SA activity was found in plyometric external rotation and flexion with Xco and plyometric push up on Bosu. Specific exercises can be selected that recruit minimal levels of UT activity (<15%): side lying plyometric external rotation and horizontal abduction or plyometric push up on the Bosu. The results of this study support exercise selection for clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.
Materials research for high-speed civil transport and generic hypersonics: Composites durability
NASA Technical Reports Server (NTRS)
Allen-Lilly, Heather; Cregger, Eric; Hoffman, Daniel; Mccool, Jim
1995-01-01
This report covers a portion of an ongoing investigation of the durability of composites for the High Speed Civil Transport (HSCT) program. Candidate HSCT composites need to possess the high-temperature capability required for supersonic flight. This program was designed to initiate the design, analysis, fabrication, and testing of equipment intended for use in validating the long-term durability of materials for the HSCT. This equipment includes thermally actuated compression and tension fixtures, hydraulic-actuated reversible load fixtures, and thermal chambers. This equipment can be used for the durability evaluation of both composite and adhesive materials. Thermally actuated fixtures are recommended for fatigue cycling when long-term thermomechanical fatigue (TMF) data are required on coupon-sized tension or compression specimens. Long term durability testing plans for polymer matrix composite specimens are included.
Fixture Design for Motion Picture and Theatrical Lighting
NASA Astrophysics Data System (ADS)
Dandridge, Susan
1987-02-01
I am the Marketing Manager for a fairly good-sized company in a very small industry which is dependent on the efforts of the kind of people attending this conference. Strand Lighting and other companies like mine supply the lighting needs of the entertainment industry. We listen to people like Dan Flannery and Bran Ferrren as well as thousands of other creative, artistic designers, manufacturing the tools they need to bring you everything from Hamlet to Dynasty, from Masterpiece Theatre to The Price is Right. We design and manufacture dimmers, computerized control equipment for the dimmers, and lighting fixtures.It it the issue of lighting fixtures for our industry that brings me here today. The total yearly volume of the entire entertainment lighting industry is estimated at only $70 million. Compare that to the billions of the defense or medical industries.
Wax Reinforces Honeycomb During Machining
NASA Technical Reports Server (NTRS)
Towell, Timothy W.; Fahringer, David T.; Vasquez, Peter; Scheidegger, Alan P.
1995-01-01
Method of machining on conventional metal lathe devised for precise cutting of axisymmetric contours on honeycomb cores made of composite (matrix/fiber) materials. Wax filling reinforces honeycomb walls against bending and tearing while honeycomb being contoured on lathe. Innovative method of machining on lathe involves preparation in which honeycomb is placed in appropriate fixture and the fixture is then filled with molten water-soluble wax. Number of different commercial waxes have been tried.
Asmanes, Charles
1979-01-01
A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.
Retractor Tool for Brain Surgery
NASA Technical Reports Server (NTRS)
Helms, R.; Hayes, T.
1982-01-01
Proposed brain-surgery tool has an octogonal fixture for positioning latex tube over incision. Eight stainless-steel wires embedded in latex extend to hold positioning fixture. Another eight are also embedded in the latex. Concentric sleeves are successively inserted into expandable latex tube. The first sleeve is placed over a solid rod. Last sleeve is a stainless-steel tube 1 inch in diameter. It is overcoated with Teflon (or equivalent) material.
NASA Astrophysics Data System (ADS)
Gui, Xulong; Luo, Xiaobing; Wang, Xiaoping; Liu, Sheng
2015-12-01
Micro-electrical-mechanical system (MEMS) has become important for many industries such as automotive, home appliance, portable electronics, especially with the emergence of Internet of Things. Volume testing with temperature compensation has been essential in order to provide MEMS based sensors with repeatability, consistency, reliability, and durability, but low cost. Particularly, in the temperature calibration test, temperature uniformity of thermal cycling based calibration chamber becomes more important for obtaining precision sensors, as each sensor is different before the calibration. When sensor samples are loaded into the chamber, we usually open the door of the chamber, then place fixtures into chamber and mount the samples on the fixtures. These operations may affect temperature uniformity in the chamber. In order to study the influencing factors of sample-loading on the temperature uniformity in the chamber during calibration testing, numerical simulation work was conducted first. Temperature field and flow field were simulated in empty chamber, chamber with open door, chamber with samples, and chamber with fixtures, respectively. By simulation, it was found that opening chamber door, sample size and number of fixture layers all have effects on flow field and temperature field. By experimental validation, it was found that the measured temperature value was consistent with the simulated temperature value.
NASA Astrophysics Data System (ADS)
Jacobs, Tevis D. B.; Wabiszewski, Graham E.; Goodman, Alexander J.; Carpick, Robert W.
2016-01-01
The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture's use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.
NASA Astrophysics Data System (ADS)
Bakker, O. J.; Gibson, C.; Wilson, P.; Lohse, N.; Popov, A. A.
2015-10-01
Due to its inherent advantages, linear friction welding is a solid-state joining process of increasing importance to the aerospace, automotive, medical and power generation equipment industries. Tangential oscillations and forge stroke during the burn-off phase of the joining process introduce essential dynamic forces, which can also be detrimental to the welding process. Since burn-off is a critical phase in the manufacturing stage, process monitoring is fundamental for quality and stability control purposes. This study aims to improve workholding stability through the analysis of fixture cassette deformations. Methods and procedures for process monitoring are developed and implemented in a fail-or-pass assessment system for fixture cassette deformations during the burn-off phase. Additionally, the de-noised signals are compared to results from previous production runs. The observed deformations as a consequence of the forces acting on the fixture cassette are measured directly during the welding process. Data on the linear friction-welding machine are acquired and de-noised using empirical mode decomposition, before the burn-off phase is extracted. This approach enables a direct, objective comparison of the signal features with trends from previous successful welds. The capacity of the whole process monitoring system is validated and demonstrated through the analysis of a large number of signals obtained from welding experiments.
Effect of Microstructure on the Strength and Fracture Energy of Bimaterial Interfaces
1993-12-31
non - dimensional plastic dissipationdensity with distance from the crack plane, y. Preliminary Analysis of Plastic Dissipation Associated with Crack...basis for emplaced in the bonding fixture, subject to a pressure finite element analysis of crack extension along the of - I MPa. The bonding fixture is... finite element analysis has been used to calculate stresses in the vicinity of a crack and the results rationalizd on the basis of low and high
Test Operations Procedure (TOP) 6-3-044. Optical Transfer Function
2009-07-27
Mounting Fixtures As required Alignment Periscope See section 4.1.6 TOP 6-3-040 27 July 2009 3 3. REQUIRED TEST CONDITIONS. 3.1 Pre-test...carefully selected. The stabilized cast iron lathe bed type, typically 2-3 m long, provides adequate support for mounting the various assemblies...combined size and weight of some vehicle mounted sights, a special mounting fixture , perhaps including a periscopic system may be required. It is
Army Reserve 63d RSC Achieves 85% Savings in Parking Lot Lighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Case study describes how the Army Reserve 63d Regional Support Command (RSC) achieved 85% energy savings and $4,000 per year in cost savings by replacing 12 old light fixtures with light-emitting diode fixtures in the military equipment parking area. This project was part of a camp-wide parking lighting retrofit which, on average, delivered 78% energy savings and a simple payback of 4.4 years.
Analysis of Nonlinear Insertion Loss of Hearing Protection Devices using an Acoustic Test Fixture
2015-09-01
USAARL Report No. 2016-05 Analysis of Nonlinear Insertion Loss of Hearing Protection Devices using an Acoustic Test Fixture By Robert Williams1...through circuitry. Talk through circuits use electro- acoustic transducers to pass ambient sounds through the protector. When the circuitry detects...the SPL of the acoustic insult. If the protective capacity is variable, it should be accounted for in the selection of appropriate HPDs. REAT
NASA Astrophysics Data System (ADS)
1988-01-01
Ultra Sales, Inc.'s fluorescent lighting fixture gets a boost in reflectivity through installation of Lightdriver, a thin tough thermoplastic film plated with aluminum, capable of reflecting 95 percent of visible light striking it. Lightdriver increases brightness without adding bulbs, and allows energy savings by removing some bulbs because the mirrorlike surface cuts light loss generally occasioned by conventional low reflectivity white painted surface above the bulbs in many fluorescent fixtures. Forty-five percent reduction in lighting electricity is attainable.
STS-57 MS4 Voss, wearing goggles, handles SCG equipment on OV-105's middeck
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 Mission Specialist 4 (MS4) Janice E. Voss, wearing goggles, handles plastic-wrapped Support of Crystal Growth (SCG) experiment equipment on the middeck of Endeavour, Orbiter Vehicle (OV) 105. Holding the SCG equipment over a portable light fixture, Voss determines the proper autoclave mixing protocols for the zeolite crystal growth experiment. The lighting fixture bracket is attached to the open airlock hatch in the foreground.
Removable partial overdentures with natural root structure and osseointegrated fixtures.
Jackson, T R
1990-10-01
The development and refinement of osseointegration have had primary impetus in treatment of the totally edentulous patient. The same principles, however, may be applied to the partially edentulous patient. Osseointegrated fixtures used in conjunction with mechanical or magnetic attachments may be used to construct partial or full overdentures. This allows treatment with removable prosthodontics in many cases in which it is not practical to achieve anchorage for a fixed prosthesis.
2001-03-28
The Aerostructures Test Wing (ATW), which consisted of an 18-inch carbon fiber test wing with surface-mounted piezoelectric strain actuators, was mounted on a special ventral flight test fixture and flown on Dryden's F-15B Research Testbed aircraft
NASA Technical Reports Server (NTRS)
Littell, Justin Anderson (Inventor); Street, Jon P. (Inventor)
2017-01-01
The modular fixturing system of the present invention is modular, reusable and capable of significant customization, both in terms of system radius and system height, allowing it to be arranged and rearranged in numerous unique configurations. The system includes multiple modular stanchions having stanchion shafts and stanchion feet that removably attach to apertures in a table. Angle brackets attached to the modular stanchions support shelves. These shelves in turn provide support to work pieces during fabrication processes such as welding.
Interior LED Lighting Technology. Navy Energy Technology Validation (Techval) Program
2015-09-01
usually on most of the time. • Consider replacing existing CFL, high-intensity discharge (HID), or halogen lamp light fixtures/ lamps with LED fixtures... lamps . What is the Technology? An LED is a semiconductor-diode that emits light when power is applied. A driver is used, much as a ballast, to...available in integrated luminaires that can be used to replace existing luminaires. LEDs are also available as direct replacement lamps for many
Detailed Design of a Pulsed Plasma Thrust Stand
NASA Astrophysics Data System (ADS)
Verbin, Andrew J.
This thesis gives a detailed design process for a pulsed type thruster. The thrust stand designed in this paper is for a Pulsed Plasma Thruster built by Sun Devil Satellite Laboratory, a student organization at Arizona State University. The thrust stand uses a torsional beam rotating to record displacement. This information, along with impulse-momentum theorem is applied to find the impulse bit of the thruster, which varies largely from other designs which focus on using the natural dynamics their fixtures. The target impulse to record on this fixture was estimated to be 275 muN-s of impulse. Through calibration and experimentation, the fixture is capable of recording an impulse of 332 muN-s +/- 14.81 muN-s, close to the target impulse. The error due to noise was characterized and evaluated to be under 5% which is deemed to be acceptable.
Darrow, Chris; Seger, Tino
2003-09-30
A transparent flow channel fluidly communicates a fluid source and a collection reservoir. An interrogating light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel, and is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. An electronic photo-detector is aligned with the light beam, and signals the presence of birefringent microcrystals in the fluid sample by generating voltage pulses. A disposable containment fixture includes the flow channel and the collection reservoir. The fixture is adapted for removable insertion into an interrogation cradle that includes optical and data processing components. The cradle rigidly positions the centerline of the flow channel orthogonal to the light beam.
Kelman, Ler.R.; Yaggee, F.L.
1958-08-01
A sleeveless cauning apparatus is described for bonding and canning uranium fuel elements under the surface of a liquid bonding alloy. The can is supported on a pedestal by vertical pegs, and an adjustable collar is placed around the upper, open end of the can, which preferably is flared to assure accurate centering in the fixture and to guide the uranium slug into the can. The fixture with a can in place is then immersed in a liquid aluminum-silicon alloy and the can becomes filled with the liquid alloy. The slug is inserted by a slug guide located vertically above the can opening. The slug settles by gravity into the can, after which a cap is emplaced. A quenching tool lifts the capped can out of the bath by means of a slot provided for it in the pedestal. This apparatus provides a simple means of canning the slug without danger of injury to the uranium metal or the aluminum can.
NASA Astrophysics Data System (ADS)
Cioată, V. G.; Kiss, I.; Alexa, V.; Raţiu, S. A.; Racov, M.
2018-01-01
In the machining process, the workpieces are installed in machining fixtures in order to establish a strictly determined position with the cutting tool or its trajectory. During the cutting process, the weight of the workpiece, the forces and moments of inertia, cutting forces and moments, clamping forces, the heat released during the cutting process determine the contact forces between the locators and the workpiece. The magnitude of these forces is important because too large value can destroy the surface of the workpiece, and a too small value can cause the workpiece to slip on the locators or even the loss of the contact with the workpiece. Both situations must be avoided. The paper presents a study, realized with CAE software, regarding the influence of the cutting temperature on the magnitude of the contact forces in a machining fixture for the milling a rectangular workpiece.
Spacecraft utensil/hand cleansing fixture. [for space shuttles
NASA Technical Reports Server (NTRS)
Rosener, A. A.; Jonkoniec, T. G.; Wilson, D. A.; Schulz, J. R.
1975-01-01
A system concept for an inflight utensil/hand cleansing fixture is described which includes the following features: (1) capability for efficient cleansing and rinsing of utensils or hands, and (2) provision for general waste fluid disposal. The design concept provides for the capability of functioning for a 30 day shuttle mission containing seven occupants/users. The long range goal is to provide a functioning system capable of operating for missions of at least 120 days. The fixture is a self-contained unit that can be installed in the standard water interface requirements. Service to the unit is a single source of unheated potable water and water is discharged from the unit into a single return waste connection. In addition, the design includes provisions for the intake and discharge of purge air and the discharge of evolved gases. Both the air and the gases are filtered or processed in the assembly before releasing them into the habitability area.
High-temperature strain cell for tomographic imaging
MacDowell, Alastair A.; Nasiatka, James; Haboub, Abdel; Ritchie, Robert O.; Bale, Hrishikesh A.
2015-06-16
This disclosure provides systems, methods, and apparatus related to the high temperature mechanical testing of materials. In one aspect, a method includes providing an apparatus. The apparatus may include a chamber. The chamber may comprise a top portion and a bottom portion, with the top portion and the bottom portion each joined to a window material. A first cooled fixture and a second cooled fixture may be mounted to the chamber and configured to hold the sample in the chamber. A plurality of heating lamps may be mounted to the chamber and positioned to heat the sample. The sample may be placed in the first and the second cooled fixtures. The sample may be heated to a specific temperature using the heating lamps. Radiation may be directed though the window material, the radiation thereafter interacting with the sample and exiting the chamber through the window material.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, Kelly L.; Foster, Rebecca; McGowan, Terry
2005-05-09
Lighting for Tomorrow was the first residential lighting fixture design competition conducted in the United States to focus on energy-efficient light sources. Sponsored by the American Lighting Association, the Consortium for Energy Efficiency, and the U.S. Department of Energy, the competition was carried out in two phases between 2002 and 2004. Five winning fixture designs were selected from a field of 24 finalists. The paper describes the competition in detail, including its origins, sponsors, structure and rules, timeline, prizes, selection criteria, and judges. The paper describes the results of the competition, including industry response, promotion and publicity efforts, technical andmore » design innovations demonstrated by the winners, and retail placements to date. Finally, the paper offers several lessons learned that are instructive for future efforts to promote high-efficiency lighting through the design competition approach.« less
Transfer of strength and power training to sports performance.
Young, Warren B
2006-06-01
The purposes of this review are to identify the factors that contribute to the transference of strength and power training to sports performance and to provide resistance-training guidelines. Using sprinting performance as an example, exercises involving bilateral contractions of the leg muscles resulting in vertical movement, such as squats and jump squats, have minimal transfer to performance. However, plyometric training, including unilateral exercises and horizontal movement of the whole body, elicits significant increases in sprint acceleration performance, thus highlighting the importance of movement pattern and contraction velocity specificity. Relatively large gains in power output in nonspecific movements (intramuscular coordination) can be accompanied by small changes in sprint performance. Research on neural adaptations to resistance training indicates that intermuscular coordination is an important component in achieving transfer to sports skills. Although the specificity of resistance training is important, general strength training is potentially useful for the purposes of increasing body mass, decreasing the risk of soft-tissue injuries, and developing core stability. Hypertrophy and general power exercises can enhance sports performance, but optimal transfer from training also requires a specific exercise program.
The effect of antimicrobial therapy on periimplantitis lesions. An experimental study in the dog.
Ericsson, I; Persson, L G; Berglundh, T; Edlund, T; Lindhe, J
1996-12-01
The objective of the present study was to evaluate the effect of systemic antibiotics and local debridement in the treatment of experimentally induced periimplantitis lesions. 5 Labrador dogs, and about 1-year old, were included in the study. In order to establish bilateral recipient sites for implants the mandibular right and left 1st molars, 4th and 3rd premolars were removed. 6 titanium fixtures (Brånemark System Nobelpharma AB, Göteborg, Sweden) were installed and standard abutments were connected 3 months after fixture installation. Cotton floss ligatures were placed in a submarginal position around the neck of the abutments and the animals were placed on a diet which allowed plaque accumulation. After 6-8 weeks, when the tissue destruction amounted to about 20% of the fixture length, the ligatures were removed. 1 month after ligature removal, an antibiotic regimen (amoxicillin and metronidazole) was initiated and maintained for 3 weeks. In the left side of the mandible, buccal and lingual mucoperiosteal flaps were elevated, the granulation tissue within the bone craters adjacent to the implants was curetted, and the abutments were removed. The exposed outer surface, the internal part of the fixtures, as well as the abutments were treated with a detergent, delmopinol. The cleaned abutments were autoclaved, and connected to the clean fixtures. The mucoperiosteal flaps were replaced to their original position, adapted to the abutments and sutured. A careful plaque control program was initiated for the left jaw quadrants. In the right side of the mandible no local treatment was given to the fixtures and the abutments following ligature removal. Furthermore, no plaque control was provided to the implant segments in the right jaws. After 4 months of healing block biopsies including one implant with adjacent hard and soft tissue were harvested and prepared for light microscopy. It was observed that systemic antimicrobial therapy, combined with implant cleaning, curettage of the bone defect and regular plaque control resulted in (i) resolution of the periimplantitis lesion, (ii) a significant recession of the marginal periimplant mucosa, and (iii) a minor additional apical shift of the base of the bone defect. In the untreated sites the plaque associated infiltrate remained and was in several sites examined in contact with the adjacent bone tissue.
Tyurin readies the NASDA exposure experiment cases for their EVA
2001-10-14
ISS003-E-6623 (14 October 2001) --- Cosmonaut Mikhail Tyurin, Expedition Three flight engineer representing Rosaviakosmos, works with hardware for the Micro-Particles Capturer (MPAC) and Space Environment Exposure Device (SEED) experiment and fixture mechanism in the Zvezda Service Module on the International Space Station (ISS). MPAC and SEED were developed by Japans National Space Development Agency (NASDA), and Russia developed the Fixture Mechanism. This image was taken with a digital still camera.
NASA Technical Reports Server (NTRS)
Turner, James E.; Mccluney, D. Scott
1991-01-01
Fixture tests O-rings for sealing ability under dynamic conditions after extended periods of compression. Hydraulic cylinder moves plug in housing. Taper of 15 degrees on plug and cavity of housing ensures that gap created between O-ring under test and wall of cavity. Secondary O-rings above and below test ring maintain pressure applied to test ring. Evaluates effects of variety of parameters, including temperature, pressure, rate of pressurization, rate and magnitude of radial gap movement, and pretest compression time.
Design of a Combined Ballistic Simulator and Primer Force Experimental Fixture
2015-08-01
preload bolt and breech, and between the breech and chamber, were found to be too loose. When heavy grease or Teflon tape was used to tighten the...increase the difficulty of removing and tightening the breech. The preload bolt does not have to be removed between firing and in future designs could use... tightened it could loosen the primer plate, so left-handed threads were machined on the primer plate. The ballistic simulator fixture was occasionally
Modelling of eddy currents related to large angle magnetic suspension test fixture
NASA Technical Reports Server (NTRS)
Britcher, Colin P.; Foster, Lucas E.
1994-01-01
This report presents a preliminary analysis of the mathematical modelling of eddy current effects in a large-gap magnetic suspension system. It is shown that eddy currents can significantly affect the dynamic behavior and control of these systems, but are amenable to measurement and modelling. A theoretical framework is presented, together with a comparison of computed and experimental data related to the Large Angle Magnetic Suspension Test Fixture at NASA Langley Research Center.
Method and system for powering and cooling semiconductor lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Telford, Steven J; Ladran, Anthony S
A semiconductor laser system includes a diode laser tile. The diode laser tile includes a mounting fixture having a first side and a second side opposing the first side and an array of semiconductor laser pumps coupled to the first side of the mounting fixture. The semiconductor laser system also includes an electrical pulse generator thermally coupled to the diode bar and a cooling member thermally coupled to the diode bar and the electrical pulse generator.
Tool calibration system for micromachining system
Miller, Donald M.
1979-03-06
A tool calibration system including a tool calibration fixture and a tool height and offset calibration insert for calibrating the position of a tool bit in a micromachining tool system. The tool calibration fixture comprises a yokelike structure having a triangular head, a cavity in the triangular head, and a port which communicates a side of the triangular head with the cavity. Yoke arms integral with the triangular head extend along each side of a tool bar and a tool head of the micromachining tool system. The yoke arms are secured to the tool bar to place the cavity around a tool bit which may be mounted to the end of the tool head. Three linear variable differential transformer's (LVDT) are adjustably mounted in the triangular head along an X axis, a Y axis, and a Z axis. The calibration insert comprises a main base which can be mounted in the tool head of the micromachining tool system in place of a tool holder and a reference projection extending from a front surface of the main base. Reference surfaces of the calibration insert and a reference surface on a tool bar standard length are used to set the three LVDT's of the calibration fixture to the tool reference position. These positions are transferred permanently to a mastering station. The tool calibration fixture is then used to transfer the tool reference position of the mastering station to the tool bit.
Noise and cardiovascular effects in workers of the sanitary fixtures industry.
Assunta, Capozzella; Ilaria, Samperi; Simone, De Sio; Gianfranco, Tomei; Teodorico, Casale; Carmina, Sacco; Anastasia, Suppi; Roberto, Giubilati; Francesco, Tomei; Valeria, Rosati Maria
2015-01-01
The aim of the present study is to evaluate whether workers in the sanitary fixtures industry are a category at risk of developing cardiovascular diseases, and in particular, whether chronic noise exposure may play a role in cardiovascular effects in exposed workers. Seventy-five employees engaged in sanitation fixtures production and a control group of sixty-four office workers, who were not exposed to agents that could damage the cardiovascular system, participated in our study. The selected workers completed a clinical-anamnestic questionnaire, and underwent a medical examination, blood pressure test, electrocardiogram (ECG), blood tests, and audiometry. Measurements of environmental noise, dust, and lead were also carried out. The exposed workers, in comparison to the control group, showed a higher frequency of hypertension, systolic and diastolic blood pressure (p<0.05, p<0.05), as well as electrocardiographic abnormalities (p<0.05). There was also a higher frequency of hypertension and electrocardiographic abnormalities among subjects with audiometric deficit compared to normoacoustic subjects (p<0.05 and p<0.05). from our study suggest that work activity in the sanitary fixtures industry can have an influence on the cardiovascular system, and noise can be the main cause of damage for the cardiovascular system in exposed workers, as cardiovascular damage seems to be linked to hearing loss. Copyright © 2014 Elsevier GmbH. All rights reserved.
Smith, Mark A; Fronk, Gaylen E; Abel, Jean M; Lacy, Ryan T; Bills, Sarah E; Lynch, Wendy J
2018-04-01
Preclinical studies consistently report that aerobic exercise decreases drug self-administration and other forms of drug-seeking behavior; however, relatively few studies have examined other types of physical activity. The purpose of the present study was to examine the effects of resistance exercise (i.e., strength training) on heroin self-administration and mRNA expression of genes known to mediate opioid reinforcement and addictive behavior in the nucleus accumbens (NAc) of heroin-exposed rats. Female rats were obtained during late adolescence and divided into two groups. Resistance exercise rats were trained to climb a vertical ladder wearing a weighted vest; sedentary control rats were placed repeatedly on the ladder oriented horizontally on its side. All rats were implanted with intravenous catheters and trained to self-administer heroin on a fixed ratio (FR1) schedule of reinforcement. mRNA expression in the NAc core and shell was examined following behavioral testing. Resistance exercise significantly decreased heroin self-administration, resulting in a downward shift in the dose-effect curve. Resistance exercise also reduced mRNA expression for mu opioid receptors and dopamine D1, D2, and D3 receptors in the NAc core. Resistance exercise increased mRNA expression of dopamine D5 receptors in the NAc shell and increased mRNA expression of brain-derived neurotrophic factor (exons I, IIB, IIC, IV, VI, IX) in the NAc core. These data indicate that resistance exercise decreases the positive reinforcing effects of heroin and produces changes in opioid and dopamine systems in the NAc of heroin-exposed rats.
Management of apraxic gait in a stroke patient.
Jantra, P; Monga, T N; Press, J M; Gervais, B J
1992-01-01
There is little information available regarding management of apraxic gait. We present a 61-year-old man with a five-year history of right-sided cerebrovascular accident, apraxic gait, difficulty in walking, and frequent falls. A CT head scan revealed moderate cerebral atrophy, a small lacunar infarction. The patient was unable to initiate walking, was bed ridden and housebound. Traditional gait training and balance exercises failed to improve his gait. Two straight canes were modified by fixing florescent horizontal projections approximately two inches up from the tip of the cane. The patient was instructed to step over the horizontal projected portion, making use of visual cues from the florescent painted projections. The patient became independent with safe ambulation after practicing for approximately three weeks and was discharged home.
Strength and Structure of Ga1-xInx as Alloys
1986-04-01
fixtures were ordered and received. An existing furnace and retort will be used to surround the compression fixture. The sample will be positioned in a B203...oncerns the experimental measurement of the flow stress and hardness as a function of temperature and In content:. High mprare hardns testing is used ...approximately 1/3 of the hardness 4 value9 so the latter indicates expected trends for yield stress. flWI1AL WORK The hardess tester used in this study was
1980-09-01
AFWAL-TR-80-41 16 a N0946 6 6 PORCELAIN ENAMEL MATERIAL TESTING PROCEDURES TO DETERMINE THE DAMPINGi l PROPERTIES AND THE RESULTS OF ,= SELECTED...15..DECLASSI FtCATION/ DOWNGRADING SCHEDULE N.A(U~~~~ ~N A. 7~ ~&:’? 16 . DISThmBUTTUSTATEMENT (o1 this Report) Approved for public release...Damping Fixture 15 Number One 6 High Temperature Enamels Damping Fixture 16 Number Two 7 Schematic of the Enamels Testing Furnace Showing 18 the
Yamamoto, Tetsuya
2007-06-01
A novel test fixture operating at a millimeter-wave band using an extrapolation range measurement technique was developed at the National Metrology Institute of Japan (NMIJ). Here I describe the measurement system using a Q-band test fixture. I measured the relative insertion loss as a function of antenna separation distance and observed the effects of multiple reflections between the antennas. I also evaluated the antenna gain at 33 GHz using the extrapolation technique.
Holding Fixture For Making Piezoelectric Acoustic Sensors
NASA Technical Reports Server (NTRS)
Hall, E. Thomas, Jr.
1993-01-01
Vacuum holding device provides quick and easy method of bonding together two strips of thin film with fast-setting epoxy adhesive. Fixture holds films in place by vacuum while adhesive applied, maintaining uniform bond line between films, providing internal connection port between nickel coats on films for center conductor of coaxial cable, and eliminating need to clean up excessive adhesive. Used to fabricate acoustic sensors for use in ambulatory fetal heart monitors. Potential for other heart-monitoring applications and other applications in which acoustic sensors used.
Testing Fixture For Microwave Integrated Circuits
NASA Technical Reports Server (NTRS)
Romanofsky, Robert; Shalkhauser, Kurt
1989-01-01
Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.
2016-03-01
work included installing new doors and windows, new plumbing fixtures, and overhead lighting, fresh paint, and tile work in 15 buildings and new...ceramic tile work in some buildings. These issues can largely be attributed to USACE’s failure to (1) fully monitor the implementation of its three-phase...and 3 support structures. The building renovations largely consisted of replacing doors, windows, carpeting, tiles , bathroom fixtures, and fans, as
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinzey, Bruce R.; Myer, Michael
This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, weremore » achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.« less
Design, Optimization and Evaluation of Integrally Stiffened Al 7050 Panel with Curved Stiffeners
NASA Technical Reports Server (NTRS)
Slemp, Wesley C. H.; Bird, R. Keith; Kapania, Rakesh K.; Havens, David; Norris, Ashley; Olliffe, Robert
2011-01-01
A curvilinear stiffened panel was designed, manufactured, and tested in the Combined Load Test Fixture at NASA Langley Research Center. The panel was optimized for minimum mass subjected to constraints on buckling load, yielding, and crippling or local stiffener failure using a new analysis tool named EBF3PanelOpt. The panel was designed for a combined compression-shear loading configuration that is a realistic load case for a typical aircraft wing panel. The panel was loaded beyond buckling and strains and out-of-plane displacements were measured. The experimental data were compared with the strains and out-of-plane deflections from a high fidelity nonlinear finite element analysis and linear elastic finite element analysis of the panel/test-fixture assembly. The numerical results indicated that the panel buckled at the linearly elastic buckling eigenvalue predicted for the panel/test-fixture assembly. The experimental strains prior to buckling compared well with both the linear and nonlinear finite element model.
Leach, David; Bergendahl, Peter Allen; Waldo, Stuart Forrest; Smith, Robert Leroy; Phelps, Robert Kim
2001-01-01
A turbine includes upper and lower inner shell sections mounting the nozzles and shrouds and which inner shell is supported by pins secured to a surrounding outer shell. To disassemble the turbine for access to the inner shell sections and rotor, an alignment fixture is secured to the lower outer shell section and has pins engaging the inner shell section. To disassemble the turbine, the inner shell weight is transferred to the lower outer shell section via the alignment fixture and cradle pins. Roller assemblies are inserted through access openings vacated by support pins to permit rotation of the lower inner shell section out of and into the lower outer shell section during disassembly and assembly. The alignment fixture includes adjusting rods for adjusting the inner shell axially, vertically, laterally and about a lateral axis. A roller over-cage is provided to rotate the inner shell and a dummy shell to facilitate assembly and disassembly in the field.
Law as a fixture between the One Health interfaces of emerging diseases.
Phelan, Alexandra L; Gostin, Lawrence O
2017-06-01
A One Health approach calls for multisectoral and multi-institutional cooperation and partnership across the interfaces of human, animal and ecosystem health risks. Without strong governance, these interfaces risk detaching, leaving gaps in capacities to prevent, detect and respond to emerging and persisting public health threats. As a crucial component of governance, law can act as the fixture between interfaces. We examine some of the many forms and foci of law and propose that the process of law-making, implementation and evaluation can provide a benefit for strengthening law as a fixture between One Health interfaces. To demonstrate this, we discuss three current examples of international legal instruments for emerging infectious diseases: the International Health Regulations, the Pandemic Influenza Preparedness Framework and the Global Action Plan on Antimicrobial Resistance. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Jiang, Jingtao; Sui, Rendong; Shi, Yan; Li, Furong; Hu, Caiqi
In this paper 3-D models of combined fixture elements are designed, classified by their functions, and saved in computer as supporting elements library, jointing elements library, basic elements library, localization elements library, clamping elements library, and adjusting elements library etc. Then automatic assembly of 3-D combined checking fixture for auto-body part is presented based on modularization theory. And in virtual auto-body assembly space, Locating constraint mapping technique and assembly rule-based reasoning technique are used to calculate the position of modular elements according to localization points and clamp points of auto-body part. Auto-body part model is transformed from itself coordinate system space to virtual assembly space by homogeneous transformation matrix. Automatic assembly of different functional fixture elements and auto-body part is implemented with API function based on the second development of UG. It is proven in practice that the method in this paper is feasible and high efficiency.
Test Fixture for Determination of Energy Absorbing Capabilities of Composite Materials
NASA Technical Reports Server (NTRS)
Lavoie, J. Andre (Inventor); Jackson, Karen E. (Inventor); Morton, John (Inventor)
1998-01-01
The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate. four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen.
NASA Technical Reports Server (NTRS)
Milder, G.
1975-01-01
The current work presents an overview of the Viking 1975 environmental testing from an engineering standpoint. An extremely large vibration test fixture had to be designed, analyzed, and integrated into a test setup that employed hydrostatic bearings in a new fashion. A vibration control system was also required that would allow for thirty-six channels of sine-wave peak select control from acceleration, force-of-strain transducers. In addition, some 68 channels of peak limiting shutdown capability were needed for backup and monitoring of other data during the forced vibration test. Pretesting included analyses of the fixture design, overturning moment, control system capabilities, and response of the entire spacecraft/fixture/exciter system to the test environment. Closed-loop control for acoustic testing was a necessity due to the fact that the Viking spacecraft took up a major portion of the volume of the 10,000 cu ft chamber. The spacecraft emerged from testing undamaged.
NASA Astrophysics Data System (ADS)
Liu, Yan; Chen, Linfeng; Tan, C. Y.; Liu, H. J.; Ong, C. K.
2005-06-01
A brief review of the methods used for broadband complex permeability measurement of magnetic thin films up to microwave frequencies is given. In particular, the working principles of the transmission-line perturbation methods for the characterization of magnetic thin films are discussed, with emphasis on short-circuited planar transmission-line perturbation methods. The algorithms for calculating the complex permeability of magnetic thin films for short-circuited planar transmission-line perturbation methods are analyzed. A shorted microstrip line is designed and fabricated as a prototype measurement fixture. The structure of the microstrip fixture and the corresponding measurement procedure are discussed in detail. A piece of 340 nm thick FeTaN thin film deposited on Si substrate using sputtering method is characterized using the microstrip fixture. An improved technique for obtaining permeability by using a saturation magnetization field is demonstrated here, and the results fit well with the Landau-Lifchitz-Gilbert theory. Approaches to extending this method to other aspects in the investigation of magnetic thin film are also discussed.
Test fixture for determination of energy absorbing capabilities of composite materials
NASA Technical Reports Server (NTRS)
Lavoie, J. Andre (Inventor); Jackson, Karen E. (Inventor); Morton, John (Inventor)
1994-01-01
The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate, four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen.
Li, Albert S; Berger, Kenneth I; Schwartz, David R; Slater, William R; Goldfarb, David S
2014-04-12
In order to develop clinical reasoning, medical students must be able to integrate knowledge across traditional subject boundaries and multiple disciplines. At least two dimensions of integration have been identified: horizontal integration, bringing together different disciplines in considering a topic; and vertical integration, bridging basic science and clinical practice. Much attention has been focused on curriculum overhauls, but our approach is to facilitate horizontal and vertical integration on a smaller scale through an interdisciplinary case study discussion and then to assess its utility. An interdisciplinary case study discussion about a critically ill patient was implemented at the end of an organ system-based, basic sciences module at New York University School of Medicine. Three clinical specialists-a cardiologist, a pulmonologist, and a nephrologist-jointly led a discussion about a complex patient in the intensive care unit with multiple medical problems secondary to septic shock. The discussion emphasized the physiologic underpinnings behind the patient's presentation and the physiologic considerations across the various systems in determining proper treatment. The discussion also highlighted the interdependence between the cardiovascular, respiratory, and renal systems, which were initially presented in separate units. After the session students were given a brief, anonymous three-question free-response questionnaire in which they were asked to evaluate and freely comment on the exercise. Students not only took away physiological principles but also gained an appreciation for various thematic lessons for bringing basic science to the bedside, especially horizontal and vertical integration. The response of the participants was overwhelmingly positive with many indicating that the exercise integrated the material across organ systems, and strengthened their appreciation of the role of physiology in understanding disease presentations and guiding appropriate therapy. Horizontal and vertical integration can be presented effectively through a single-session case study, with complex patient cases involving multiple organ systems providing students opportunities to integrate their knowledge across organ systems while emphasizing the importance of physiology in clinical reasoning. Furthermore, having several clinicians from different specialties discuss the case together can reinforce the matter of integration across multiple organ systems and disciplines in students' minds.
2014-01-01
Background In order to develop clinical reasoning, medical students must be able to integrate knowledge across traditional subject boundaries and multiple disciplines. At least two dimensions of integration have been identified: horizontal integration, bringing together different disciplines in considering a topic; and vertical integration, bridging basic science and clinical practice. Much attention has been focused on curriculum overhauls, but our approach is to facilitate horizontal and vertical integration on a smaller scale through an interdisciplinary case study discussion and then to assess its utility. Methods An interdisciplinary case study discussion about a critically ill patient was implemented at the end of an organ system-based, basic sciences module at New York University School of Medicine. Three clinical specialists—a cardiologist, a pulmonologist, and a nephrologist—jointly led a discussion about a complex patient in the intensive care unit with multiple medical problems secondary to septic shock. The discussion emphasized the physiologic underpinnings behind the patient’s presentation and the physiologic considerations across the various systems in determining proper treatment. The discussion also highlighted the interdependence between the cardiovascular, respiratory, and renal systems, which were initially presented in separate units. After the session students were given a brief, anonymous three-question free-response questionnaire in which they were asked to evaluate and freely comment on the exercise. Results Students not only took away physiological principles but also gained an appreciation for various thematic lessons for bringing basic science to the bedside, especially horizontal and vertical integration. The response of the participants was overwhelmingly positive with many indicating that the exercise integrated the material across organ systems, and strengthened their appreciation of the role of physiology in understanding disease presentations and guiding appropriate therapy. Conclusions Horizontal and vertical integration can be presented effectively through a single-session case study, with complex patient cases involving multiple organ systems providing students opportunities to integrate their knowledge across organ systems while emphasizing the importance of physiology in clinical reasoning. Furthermore, having several clinicians from different specialties discuss the case together can reinforce the matter of integration across multiple organ systems and disciplines in students’ minds. PMID:24725336
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.
Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon; Lee, Keun-Woo
2016-12-01
The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 10 6 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups ( P >.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.
2016-08-05
publication 11 July 2016 Published 5 August 2016 Abstract A frictionless cart in the shape of a right triangle (with the vertical side forward) is...elastically impacted by vertically falling raindrops. The speed of the cart as a function of time can be analytically deduced as an exercise in the use...horizontal surface under the impulse of raindrops (or hail) falling vertically at terminal speed u that bounce elastically [4, 5] off the cart’s two
Villar, Rodrigo; Hughson, Richard L
2013-03-01
Changes in vascular conductance (VC) are required to counter changes in muscle perfusion pressure (MPP) to maintain muscle blood flow (MBF) during exercise. We investigated the recruitment of VC as a function of peak VC measured in three body positions at two different work rates to test the hypothesis that adaptations in VC compensated changes in MPP at low-power output (LPO), but not at high-power output (HPO). Eleven healthy volunteers exercised at LPO and HPO (repeated plantar flexion contractions at 20-30% maximal voluntary contraction, respectively) in horizontal (HOR), 35° head-down tilt (HDT), and 45° head-up tilt (HUT). Muscle blood flow velocity and popliteal diameter were measured by ultrasound to determine MBF, and VC was estimated by dividing MBF flow by MPP. Peak VC was unaffected by body position. The rates of increase in MBF and VC were significantly faster in HUT and slower in HDT than HOR, and rates were faster in LPO than HPO. During LPO exercise, the increase in, and steady-state values of, MBF were less for HUT and HDT than HOR; the increase in VC was less in HUT than HOR and HDT. During HPO exercise, MBF in the HDT was reduced compared with HOR and HUT, even though VC reached 92% VC peak, which was greater than HOR, which was, in turn, greater than HUT. Reduced MBF during HPO HDT exercise had the functional consequence of a significant increase in muscle electromyographic index, revealing the effects of MPP on O2 delivery during exercise.
Resistance exercise as a countermeasure to disuse-induced bone loss.
Shackelford, L C; LeBlanc, A D; Driscoll, T B; Evans, H J; Rianon, N J; Smith, S M; Spector, E; Feeback, D L; Lai, D
2004-07-01
During spaceflight, skeletal unloading results in loss of bone mineral density (BMD). This occurs primarily in the spine and lower body regions. This loss of skeletal mass could prove hazardous to astronauts on flights of long duration. In this study, intense resistance exercise was used to test whether a training regimen would prevent the loss of BMD that accompanies disuse. Nine subjects (5 men, 4 women) participated in a supine maximal resistance exercise training program during 17 wk of horizontal bed rest. These subjects were compared with 18 control subjects (13 men, 5 women) who followed the same bed rest protocol without exercise. Determination of treatment effect was based on measures of BMD, bone metabolism markers, and calcium balance obtained before, during, and after bed rest. Exercisers and controls had significantly (P < 0.05) different means, represented by the respective following percent changes: lumbar spine BMD, +3% vs. -1%; total hip BMD, +1% vs. -3%; calcaneus BMD, +1% vs. -9%; pelvis BMD, -0.5% vs. -3%; total body BMD, 0% vs. -1%; bone-specific alkaline phosphatase, +64% vs. 0%; alkaline phosphatase, +31% vs. +5%; osteocalcin, +43% vs. +10%; 1,25 dihydroxyvitamin D, +12% vs. -15%; parathyroid hormone intact molecule, +18% vs. -25%; and serum and ionized calcium, -1% vs. +1%. The difference in net calcium balance was also significant (+21 mg/day vs. -199 mg/day, exercise vs. control). The gastrocnemius and soleus muscle volumes decreased significantly in the exercise group, but the loss was significantly less than observed in the control group. The results indicate that resistance exercise had a positive treatment effect and thus might be useful as a countermeasure to prevent the deleterious skeletal changes associated with long-duration spaceflight.
NASA Technical Reports Server (NTRS)
Hackney, Kyle J.; Scott, Jessica M.; Buxton, Roxanne; Redd-Goetchius, Elizabeth; Crowell, J. Brent; Everett, Meghan E.; Wickwire, Jason; Ryder, Jeffrey W.; Bloomberg, Jacob J.; Ploutz-Snyder, Lori L.
2011-01-01
Unloading of the musculoskeletal system during space flight results in deconditioning that may impair mission-related task performance in astronauts. Exercise countermeasures have been frequently tested during bed rest (BR) and limb suspension; however, high-intensity, short-duration exercise prescriptions have not been fully explored. PURPOSE: To determine if a high intensity resistance, interval, and aerobic exercise program could protect against muscle atrophy and dysfunction when performed during short duration BR. METHODS: Nine subjects (1 female, 8 male) performed a combination of supine exercises during 2 weeks of horizontal BR. Resistance exercise (3 d / wk) consisted of squat, leg press, hamstring curl, and heel raise exercises (3 sets, 12 repetitions). Aerobic (6 d / wk) sessions alternated continuous (75% VO2 peak) and interval exercise (30 s, 2 min, and 4 min) and were completed on a supine cycle ergometer and vertical treadmill, respectively. Muscle volumes of the upper leg were calculated pre, mid, and post-BR using magnetic resonance imaging. Maximal isometric force (MIF), rate of force development (RFD), and peak power of the lower body extensors were measured twice before BR (averaged to represent pre) and once post BR. ANOVA with repeated measures and a priori planned contrasts were used to test for differences. RESULTS: There were no changes to quadriceps, hamstring, and adductor muscle volumes at mid and post BR time points compared to pre BR (Table 1). Peak power increased significantly from 1614 +/- 372 W to 1739 +/- 359 W post BR (+7.7%, p = 0.035). Neither MIF (pre: 1676 +/- 320 N vs. post: 1711 +/- 250 N, +2.1%, p = 0.333) nor RFD (pre: 7534 +/- 1265 N/ms vs. post: 6951 +/- 1241 N/ms, -7.7%, p = 0.136) were significantly impaired post BR.
Resistance exercise as a countermeasure to disuse-induced bone loss
NASA Technical Reports Server (NTRS)
Shackelford, L. C.; LeBlanc, A. D.; Driscoll, T. B.; Evans, H. J.; Rianon, N. J.; Smith, S. M.; Spector, E.; Feeback, D. L.; Lai, D.
2004-01-01
During spaceflight, skeletal unloading results in loss of bone mineral density (BMD). This occurs primarily in the spine and lower body regions. This loss of skeletal mass could prove hazardous to astronauts on flights of long duration. In this study, intense resistance exercise was used to test whether a training regimen would prevent the loss of BMD that accompanies disuse. Nine subjects (5 men, 4 women) participated in a supine maximal resistance exercise training program during 17 wk of horizontal bed rest. These subjects were compared with 18 control subjects (13 men, 5 women) who followed the same bed rest protocol without exercise. Determination of treatment effect was based on measures of BMD, bone metabolism markers, and calcium balance obtained before, during, and after bed rest. Exercisers and controls had significantly (P < 0.05) different means, represented by the respective following percent changes: lumbar spine BMD, +3% vs. -1%; total hip BMD, +1% vs. -3%; calcaneus BMD, +1% vs. -9%; pelvis BMD, -0.5% vs. -3%; total body BMD, 0% vs. -1%; bone-specific alkaline phosphatase, +64% vs. 0%; alkaline phosphatase, +31% vs. +5%; osteocalcin, +43% vs. +10%; 1,25 dihydroxyvitamin D, +12% vs. -15%; parathyroid hormone intact molecule, +18% vs. -25%; and serum and ionized calcium, -1% vs. +1%. The difference in net calcium balance was also significant (+21 mg/day vs. -199 mg/day, exercise vs. control). The gastrocnemius and soleus muscle volumes decreased significantly in the exercise group, but the loss was significantly less than observed in the control group. The results indicate that resistance exercise had a positive treatment effect and thus might be useful as a countermeasure to prevent the deleterious skeletal changes associated with long-duration spaceflight.
18. Photographic copy of photograph, dated 20 April 1971 (original ...
18. Photographic copy of photograph, dated 20 April 1971 (original print in possession of CSSD-HO, Huntsville, AL). Photographer unknown. View of missile site control building interior. At the interior of the turret, one can see the inspection fixture (furnished by the weapon system contractor) being installed on the antenna array support ring. This fixture was used to check the locations of the tapped holes through 36 shear key lugs - Stanley R. Mickelsen Safeguard Complex, Missile Site Control Building, Northeast of Tactical Road; southeast of Tactical Road South, Nekoma, Cavalier County, ND
Kramer, D.P.
1994-08-09
Hermetic fiber optic-to-metal components and method for making hermetic fiber optic-to-metal components by assembling and fixturing elements comprising a metal shell, a glass preform, and a metal-coated fiber optic into desired relative positions and then sealing said fixtured elements preferably using a continuous heating process is disclosed. The resultant hermetic fiber optic-to-metal components exhibit high hermeticity and durability despite the large differences in thermal coefficients of expansion among the various elements. 3 figs.
Analysis of the stress state in an Iosipescu sheartest specimen
NASA Technical Reports Server (NTRS)
Walrath, D. E.; Adams, D. F.
1983-01-01
The state of stress in an Iosipescu shear test specimen is analyzed, utilizing a finite element computer program. The influence of test fixture configuration on this stress state is included. Variations of the standard specimen configuration, including notch depth, notch angle, and notch root radius are modeled. The purpose is to establish guidelines for a specimen geometry which will accommodate highly orthotropic materials while minimizing stress distribution nonuniformities. Materials ranging from isotropic to highly orthotropic are considered. An optimum specimen configuration is suggested, along with changes in the test fixture.
Apparatus and method for electroforming high aspect ratio micro-parts
Hachman, John T [Stockton, CA; Losey, Matthew W [Rancho Cucamonga, CA; McLean, Dorrance E [Manteca, CA
2009-11-27
A fixture is disclosed to more easily affix a workpiece in the proper orientation and spacing with sealed electrical interconnection within an electrochemical plating bath. The workpiece can be any planar metallic or non-metallic substrate such as a silicon wafer commonly used in LIGA or microsystem fabrication. The fixture described allows the workpiece to be submerged deep within an electrolytic cell, facing upwards, and allows easy transfer from one cell to another. The edges, backside, and electrical connections are sealed and protected from the electrolyte.
2008-07-11
CAPE CANAVERAL, Fla. – The thermal vacuum fixture arrives at NASA's Kennedy Space Center. The fixture will be used to hold the carrier and flight support system for the STS-125 Hubble Space Telescope Servicing Mission 4. Space shuttle Atlantis is targeted to launch on the STS-125 mission Oct. 8. The mission crew will perform history-making, on-orbit “surgery” on two important science instruments aboard the telescope. After capturing the telescope, two teams of spacewalking astronauts will perform the repairs during five planned spacewalks. Photo credit: NASA/Jack Pfaller
2016-12-01
blend of a hydraulically reactive silicate cement with a glass enameling frit that is fused to steel . Research has shown that when Portland cement is...Silicate Coatings for Protecting and Bonding Reinforcing Steel in Cement -Based Composites,” presented at 26th Army Science Conference, Orlando, FL...Prevent Corrosion of Steel Fixtures Attached to Masonry Walls Final Report on Project F10-AR12 Co ns tr uc tio n En gi ne er in g R es ea rc h La
2008-07-11
CAPE CANAVERAL, Fla. – The thermal vacuum fixture arrives at the Payload Hazardous Servicing Center at NASA's Kennedy Space Center. The fixture will be used to hold the carrier and flight support system for the STS-125 Hubble Space Telescope Servicing Mission 4. Space shuttle Atlantis is targeted to launch on the STS-125 mission Oct. 8. The mission crew will perform history-making, on-orbit “surgery” on two important science instruments aboard the telescope. After capturing the telescope, two teams of spacewalking astronauts will perform the repairs during five planned spacewalks. Photo credit: NASA/Jack Pfaller
The role of physical activity in bone health: a new hypothesis to reduce risk of vertebral fracture.
Sinaki, Mehrsheed
2007-08-01
Locomotion has always been a major criterion for human survival. Thus, it is no surprise that science supports the dependence of bone health on weight-bearing physical activities. The effect of physical activity on bone is site-specific. Determining how to perform osteogenic exercises, especially in individuals who have osteopenia or osteoporosis, without exceeding the biomechanical competence of bone always poses a dilemma and must occur under medical advice. This article presents the hypothesis that back exercises performed in a prone position, rather than a vertical position, may have a greater effect on decreasing the risk for vertebral fractures without resulting in compression fracture. The risk for vertebral fractures can be reduced through improvement in the horizontal trabecular connection of vertebral bodies.
Tread drum for animals. [having an electrical shock station
NASA Technical Reports Server (NTRS)
Howard, W. H. (Inventor)
1978-01-01
A device for exercising animals such as primates is described, which includes a cylindrical housing mounted for rotation about a horizontal axis of revolution and has a cylindrical treadway portion on which the animal treads while the drum is rotated by means of a motorized drive. The treadway portion of the drum includes an electrode structure with sectors being independently energizable by means of a commutator and source of potential so that an electrical shock station is created behind a running-in-place station on the moving treadway. In this manner, if the animal should fall behind its running-in-place station, it may be shocked by treading on the energized electrode structure. One end of the tread drum comprises a transparent wall for unobstructed viewing of the animal being exercised.
Taylor, Lee; Fitch, Natalie; Castle, Paul; Watkins, Samuel; Aldous, Jeffrey; Sculthorpe, Nicholas; Midgely, Adrian; Brewer, John; Mauger, Alexis
2014-01-01
Soccer referees enforce the laws of the game and the decisions they make can directly affect match results. Fixtures within European competitions take place in climatic conditions that are often challenging (e.g., Moscow ~ -5°C, Madrid ~30°C). Effects of these temperatures on player performance are well-documented; however, little is known how this environmental stress may impair cognitive performance of soccer referees and if so, whether exercise exasperates this. The present study aims to investigate the effect of cold [COLD; -5°C, 40% relative humidity (RH)], hot (HOT; 30°C, 40% RH) and temperate (CONT; 18°C, 40% RH) conditions on decision making during soccer specific exercise. On separate occasions within each condition, 13 physically active males; either semi-professional referees or semi-professional soccer players completed three 90 min intermittent treadmill protocols that simulated match play, interspersed with 4 computer delivered cognitive tests to measure vigilance and dual task capacity. Core and skin temperature, heart rate, rating of perceived exertion (RPE) and thermal sensation (TS) were recorded throughout the protocol. There was no significant difference between conditions for decision making in either the dual task (interaction effects: FALSE p = 0.46; MISSED p = 0.72; TRACKING p = 0.22) or vigilance assessments (interaction effects: FALSE p = 0.31; HIT p = 0.15; MISSED p = 0.17) despite significant differences in measured physiological variables (skin temperature: HOT vs. CONT 95% CI = 2.6 to 3.9, p < 0.001; HOT vs. COLD 95% CI = 6.6 to 9.0, p < 0.001; CONT vs. COLD 95% CI = 3.4 to 5.7, p < 0.01). It is hypothesized that the lack of difference observed in decision making ability between conditions was due to the exercise protocol used, as it may not have elicited an appropriate and valid soccer specific internal load to alter cognitive functioning.
[Basic mechanisms of QRS voltage changes on ECG of healthy subjects during the exercise test].
Saltykova, M M
2015-01-01
Electrocardiography is the most commonly used technique for detection stress-induced myocardial ischemia. However, the sensitivity of ECG-criteria is not high. One of the major problem is the difficulty in differentiating ECG changes caused by various factors. The aim of this study was to evaluate the dependence of the QRS voltage changes during exercise on parameters of central hemodynamics, gender particularities and to reveal mechanisms causing these changes. To eliminate the effect of changes in cardiomyocytes transmembrane potentials under the influence of the neurotransmitters of the autonomic nervous system during stepwise increasing exercises and/or due to a lack of ATP results from inadequate myocardial blood flow only healthy subjects not older than 35 years were included in the study (7 men and 7 women) and only periods of ventricular depolarization (QRS complex on the ECG) were included in the analysis. We compared the changes of QRS waves during exercise sessions with two upper and one lower limbs in both men and women. The exercise load was twice bigger in exercise with one leg relative to exercise with two arms. Responses of heart rate and systolic arterial pressure were similar. Amplitude of S-wave in left chest leads significantly increased in both sessions without significant difference between augmentations in the sessions and in groups of men and women. Significant relationship between the S wave augmentation and the peak systolic arterial pressure were revealed. Furthermore, the QRS changes during the exercise with vertical and a horizontal torso position were compared to assess the impact of diastolic arterial pressure and displacement of the diaphragm and heart rotation due to increase of abdominal pressure during the last steps of exercise. The obtained results allow us to exclude the impact of the heart position and size changes, as well as the exercise load on S-wave changes and make a conclusion about the dependence of this parameter on the value of systolic blood pressure.
Reliability and Failure Modes of a Hybrid Ceramic Abutment Prototype.
Silva, Nelson Rfa; Teixeira, Hellen S; Silveira, Lucas M; Bonfante, Estevam A; Coelho, Paulo G; Thompson, Van P
2018-01-01
A ceramic and metal abutment prototype was fatigue tested to determine the probability of survival at various loads. Lithium disilicate CAD-milled abutments (n = 24) were cemented to titanium sleeve inserts and then screw attached to titanium fixtures. The assembly was then embedded at a 30° angle in polymethylmethacrylate. Each (n = 24) was restored with a resin-cemented machined lithium disilicate all-ceramic central incisor crown. Single load (lingual-incisal contact) to failure was determined for three specimens. Fatigue testing (n = 21) was conducted employing the step-stress method with lingual mouth motion loading. Failures were recorded, and reliability calculations were performed using proprietary software. Probability Weibull curves were calculated with 90% confidence bounds. Fracture modes were classified with a stereomicroscope, and representative samples imaged with scanning electron microscopy. Fatigue results indicated that the limiting factor in the current design is the fatigue strength of the abutment screw, where screw fracture often leads to failure of the abutment metal sleeve and/or cracking in the implant fixture. Reliability for completion of a mission at 200 N load for 50K cycles was 0.38 (0.52% to 0.25 90% CI) and for 100K cycles was only 0.12 (0.26 to 0.05)-only 12% predicted to survive. These results are similar to those from previous studies on metal to metal abutment/fixture systems where screw failure is a limitation. No ceramic crown or ceramic abutment initiated fractures occurred, supporting the research hypothesis. The limiting factor in performance was the screw failure in the metal-to-metal connection between the prototyped abutment and the fixture, indicating that this configuration should function clinically with no abutment ceramic complications. The combined ceramic with titanium sleeve abutment prototype performance was limited by the fatigue degradation of the abutment screw. In fatigue, no ceramic crown or ceramic abutment components failed, supporting the research hypothesis with a reliability similar to that of all-metal abutment fixture systems. A lithium disilcate abutment with a Ti alloy sleeve in combination with an all-ceramic crown should be expected to function clinically in a satisfactory manner. © 2016 by the American College of Prosthodontists.
Control of robot assistant for rehabilitation of upper extremities.
Kostić, Miloš D; Popović, Mirjana B; Popović, Dejan B
2012-01-01
The assisted movement in humans with paresis of upper extremities is becoming popular for neurorehabilitation. We propose a novel method for trajectory selection and assistance control. This paper presents simulation of a planar two degrees of freedom robot that assists horizontal movement of the hand. The control assumes that during the exercise the hand needs to follow healthy alike trajectories. The robot is assumed to provide minimal assistance and operate as a teacher of the movement.
Suitner, Caterina; Maass, Anne; Bettinsoli, Maria Laura; Carraro, Luciana; Kumar, Serena
2017-01-01
Five studies investigated the role of handedness and effort in horizontal spatial bias related to agency (Spatial Agency Bias, SAB). A Pilot Study (n = 33) confirmed the basic assumption that rightward writing requires greater effort from left- than from right-handers. In three studies, Italian students (n = 591 right-handed, n = 115 left-handed) were found to start drawings on the left, proceeding rightward (Study 1a, 1b), and to draw moving objects with a rightward orientation in line with script direction (Study 1c). These spatial asymmetries were displayed stronger by left- than by right-handed primacy school children, arguably due to the greater effort involved in learning how to write in a rightward fashion. Once writing has become fully automatic (high school) right- and left-handed students showed comparable spatial bias (Study 1c). The hypothesized role of effort was tested explicitly in Study 2 in which 99 right-handed adults learned a new (leftward) spatial trajectory through an easy or difficult motor exercise. The habitual rightward bias was reliably reduced, especially among those who performed a difficult task requiring greater effort. Together, findings are largely in line with the body specificity hypothesis (Casasanto, 2011 ) and suggest that spatial asymmetries are learned and unlearned most efficiently through effortful motor exercises.
Tilt to horizontal global solar irradiance conversion: application to PV systems data
NASA Astrophysics Data System (ADS)
Housmans, Caroline; Leloux, Jonathan; Bertrand, Cédric
2017-04-01
Many transposition models have been proposed in the literature to convert solar irradiance on the horizontal plane to that on a tilted plane requiring that at least two of the three solar components (i.e. global, direct and diffuse) are known. When only global irradiance measurements are available, the conversion from horizontal to tilted planes is still possible but in this case transposition models have to be coupled with decomposition models (i.e. models that predict the direct and diffuse components from the global one). Here, two different approaches have been considered to solve the reverse process, i.e. the conversion from tilted to horizontal: (i) one-sensor approach and (ii) multi-sensors approach. Because only one tilted plane is involved in the one-sensor approach, a decomposition model need to be coupled with a transposition model to solve the problem. By contrast, at least two tilted planes being considered in the multi-sensors approach, only a transposition model is required to perform the conversion. First, global solar irradiance measurements recorded on the roof of the Royal Meteorological Institute of Belgium's radiation tower in Uccle were used to evaluate the performance of both approaches. Four pyranometers (one mounted in the horizontal plane and three on inclined surfaces with different tilts and orientations) were involved in the validation exercise. Second, the inverse transposition was applied to tilted global solar irradiance values retrieved from the energy production registered at residential PV systems located in the vicinity of Belgian radiometric stations operated by RMI (for validation purposes).
A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments
Park, Ji-Man; Lee, Jai-Bong; Heo, Seong-Joo
2014-01-01
PURPOSE The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ±0.1 µm at 50 points. RESULTS Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment. PMID:24605206
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant
Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon
2016-01-01
PURPOSE The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 106 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment. PMID:28018564
NASA Technical Reports Server (NTRS)
Islam, Akm Anwarul; Dempsey, Paula J.; Feldman, Jason; Larsen, Chris
2014-01-01
Health monitoring of rotorcraft components, currently being performed by Health and Usage Monitoring Systems through analyses of vibration signatures of dynamic mechanical components, is very important for their safe and economic operation. HUMS analyze vibration signatures associated with faults and quantify them as condition indicators to predict component behavior. Vibration transfer paths are characterized by frequency response functions derived from the input/output relationship between applied force and dynamic response through a structure as a function of frequency. With an objective to investigate the differences in transfer paths, transfer path measurements were recorded under similar conditions in the left and right nose gearboxes of an AH-64 helicopter and in an isolated left nose gearbox in a test fixture at NASA Glenn Research Center. The test fixture enabled the application of measured torques-common during an actual operation. An impact hammer as well as commercial and lab piezo shakers, were used in conjunction with two types of commercially available accelerometers to collect the vibration response under various test conditions. The frequency response functions measured under comparable conditions of both systems were found to be consistent. Measurements made on the fixture indicated certain real-world installation and maintenance issues, such as sensor alignments, accelerometer locations and installation torques, had minimal effect. However, gear vibration transfer path dynamics appeared to be somewhat dependent on the presence of oil, and the transfer path dynamics were notably different if the force input was on the internal ring gear rather than on the external gearbox case.
Simulated Space Environmental Testing on Thin Films
NASA Technical Reports Server (NTRS)
Russell, Dennis A.; Fogdall, Larry B.; Bohnhoff-Hlavacek, Gail; Connell, John W. (Technical Monitor)
2000-01-01
An exploratory program has been conducted, to irradiate some mature commercial and some experimental polymer films with radiation simulating certain Earth orbits, and to obtain data about the response of each test film's reflective and tensile properties. Protocols to conduct optimized tests were considered and developed to a "prototype" level during this program. Fifteen polymer film specimens were arranged on a specially designed test fixture. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture containing the films was installed in a clean vacuum chamber where protons, electrons and solar ultraviolet (UV) radiation could simultaneously irradiate the specimens. Near realtime UV rates were used, whereas proton and electron rates were accelerated appreciably to simulate 5 years in orbit during a two month test. Periodically, the spectral reflectance of each film was measured in situ. After the end of the irradiation, final reflectance measurements were made in situ, and solar absorptance values were derived for each specimen. These samples were then measured in air for thermal emittance and for tensile strength. Most specimens withstood the irradiation intact, but with reduced reflectance (increased solar absorptance). Thermal emittance changed slightly in several materials, as did their tensile strength and elongation at break. Conclusions are drawn about the performance of the films. Simulated testing to an expected 5 year dose of electrons and protons consistent with those expected at L2 and 0.98 AU orbits and 100 equivalent solar hours exposure.
Fixture congestion modulates post-match recovery kinetics in professional soccer players.
Lundberg, Tommy R; Weckström, Kristoffer
2017-01-01
This study examined the influence of fixture congestion on physical performance and biochemical variables in professional male footballers. After 3 competitive matches within a week (3M cycle), 16 players underwent blood sampling and field testing 72 h after the last match. The same tests were performed after a regular 1 match-week cycle (1M cycle). The 1M vs. 3M change scores were compared between Congested (high match exposure) and non-selected Control players. The change score in muscle soreness was greater (effect size 1.0; CI 0.0-1.9) in the Congested players than Controls, indicating a possible negative effect of fixture congestion. There were no effects on sprint and jump performance. The change in plasma (P)-Urea was greater in Congested players than controls (effect size 1.3; CI 0.3-2.2). The effects on other blood variables were either non-existing/trivial, or unclear. Altogether, physical fitness and immune function were not compromised by match congestion, yet some indices of physiological stress and muscle damage were still evident.
NASA Technical Reports Server (NTRS)
Kuhlman, E. A.; Baranowski, L. C.
1977-01-01
The effects of the Thermal Protection Subsystem (TPS) contamination on the space shuttle orbiter S band quad antenna due to multiple mission buildup are discussed. A test fixture was designed, fabricated and exposed to ten cycles of simulated ground and flight environments. Radiation pattern and impedance tests were performed to measure the effects of the contaminates. The degradation in antenna performance was attributed to the silicone waterproofing in the TPS tiles rather than exposure to the contaminating sources used in the test program. Validation of the accuracy of an analytical thermal model is discussed. Thermal vacuum tests with a test fixture and a representative S band quad antenna were conducted to evaluate the predictions of the analytical thermal model for two orbital heating conditions and entry from each orbit. The results show that the accuracy of predicting the test fixture thermal responses is largely dependent on the ability to define the boundary and ambient conditions. When the test conditions were accurately included in the analytical model, the predictions were in excellent agreement with measurements.
1999-02-23
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building's high bay, the Rotation Handling Fixture (RHF), with a simulated module attached, is lowered by crane into the altitude chamber below during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, depositing it into the altitude chamber for leak testing. The chamber was recently reactivated after a 24-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
1999-02-23
KENNEDY SPACE CENTER, FLA. -- Viewed from inside the altitude chamber in the Operations and Checkout Building's high bay, the Rotation Handling Fixture (RHF), with a simulated module attached, is lowered during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, depositing it into the altitude chamber for leak testing. The chamber was recently reactivated after a 24-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
1999-02-23
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building's high bay, a crane lifts the Rotation Handling Fixture (RHF) and simulated module during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, lifting it up and into an altitude chamber for leak testing. The chamber was recently reactivated after a 24-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
Prototype wash water renovation system integration with government-furnished wash fixture
NASA Technical Reports Server (NTRS)
1984-01-01
The requirements of a significant quantity of proposed life sciences experiments in Shuttle payloads for available wash water to support cleansing operations has provided the incentive to develop a technique for wash water renovation. A prototype wash water waste renovation system which has the capability to process the waste water and return it to a state adequate for reuse in a typical cleansing fixture designed to support life science experiments was investigated. The resulting technology is to support other developments efforts pertaining to water reclamation by serving as a pretreatment step for subsequent reclamation procedures.
2008-07-11
CAPE CANAVERAL, Fla. – The thermal vacuum fixture is transferred to a transporter in front of the Payload Hazardous Servicing Center at NASA's Kennedy Space Center. The fixture will be used to hold the carrier and flight support system for the STS-125 Hubble Space Telescope Servicing Mission 4. Space shuttle Atlantis is targeted to launch on the STS-125 mission Oct. 8. The mission crew will perform history-making, on-orbit “surgery” on two important science instruments aboard the telescope. After capturing the telescope, two teams of spacewalking astronauts will perform the repairs during five planned spacewalks. Photo credit: NASA/Jack Pfaller
Secukinumab in plaque psoriasis--results of two phase 3 trials.
Langley, Richard G; Elewski, Boni E; Lebwohl, Mark; Reich, Kristian; Griffiths, Christopher E M; Papp, Kim; Puig, Lluís; Nakagawa, Hidemi; Spelman, Lynda; Sigurgeirsson, Bárður; Rivas, Enrique; Tsai, Tsen-Fang; Wasel, Norman; Tyring, Stephen; Salko, Thomas; Hampele, Isabelle; Notter, Marianne; Karpov, Alexander; Helou, Silvia; Papavassilis, Charis
2014-07-24
Interleukin-17A is considered to be central to the pathogenesis of psoriasis. We evaluated secukinumab, a fully human anti-interleukin-17A monoclonal antibody, in patients with moderate-to-severe plaque psoriasis. In two phase 3, double-blind, 52-week trials, ERASURE (Efficacy of Response and Safety of Two Fixed Secukinumab Regimens in Psoriasis) and FIXTURE (Full Year Investigative Examination of Secukinumab vs. Etanercept Using Two Dosing Regimens to Determine Efficacy in Psoriasis), we randomly assigned 738 patients (in the ERASURE study) and 1306 patients (in the FIXTURE study) to subcutaneous secukinumab at a dose of 300 mg or 150 mg (administered once weekly for 5 weeks, then every 4 weeks), placebo, or (in the FIXTURE study only) etanercept at a dose of 50 mg (administered twice weekly for 12 weeks, then once weekly). The objective of each study was to show the superiority of secukinumab over placebo at week 12 with respect to the proportion of patients who had a reduction of 75% or more from baseline in the psoriasis area-and-severity index score (PASI 75) and a score of 0 (clear) or 1 (almost clear) on a 5-point modified investigator's global assessment (coprimary end points). The proportion of patients who met the criterion for PASI 75 at week 12 was higher with each secukinumab dose than with placebo or etanercept: in the ERASURE study, the rates were 81.6% with 300 mg of secukinumab, 71.6% with 150 mg of secukinumab, and 4.5% with placebo; in the FIXTURE study, the rates were 77.1% with 300 mg of secukinumab, 67.0% with 150 mg of secukinumab, 44.0% with etanercept, and 4.9% with placebo (P<0.001 for each secukinumab dose vs. comparators). The proportion of patients with a response of 0 or 1 on the modified investigator's global assessment at week 12 was higher with each secukinumab dose than with placebo or etanercept: in the ERASURE study, the rates were 65.3% with 300 mg of secukinumab, 51.2% with 150 mg of secukinumab, and 2.4% with placebo; in the FIXTURE study, the rates were 62.5% with 300 mg of secukinumab, 51.1% with 150 mg of secukinumab, 27.2% with etanercept, and 2.8% with placebo (P<0.001 for each secukinumab dose vs. comparators). The rates of infection were higher with secukinumab than with placebo in both studies and were similar to those with etanercept. Secukinumab was effective for psoriasis in two randomized trials, validating interleukin-17A as a therapeutic target. (Funded by Novartis Pharmaceuticals; ERASURE and FIXTURE ClinicalTrials.gov numbers, NCT01365455 and NCT01358578, respectively.).
Wang, Zhuo; Guo, Yumei; Myers, Kalisa G; Heintz, Ryan; Holschneider, Daniel P
2015-05-01
Exercise modality and complexity play a key role in determining neurorehabilitative outcome in Parkinson's disease (PD). Exercise training (ET) that incorporates both motor skill training and aerobic exercise has been proposed to synergistically improve cognitive and automatic components of motor control in PD patients. Here we introduced such a skilled aerobic ET paradigm in a rat model of dopaminergic deafferentation. Rats with bilateral, intra-striatal 6-hydroxydopamine lesions were exposed to forced ET for 4weeks, either on a simple running wheel (non-skilled aerobic exercise, NSAE) or on a complex wheel with irregularly spaced rungs (skilled aerobic exercise, SAE). Cerebral perfusion was mapped during horizontal treadmill walking or at rest using [(14)C]-iodoantipyrine 1week after the completion of ET. Regional cerebral blood flow (rCBF) was quantified by autoradiography and analyzed in 3-dimensionally reconstructed brains by statistical parametric mapping. SAE compared to NSAE resulted in equal or greater recovery in motor deficits, as well as greater increases in rCBF during walking in the prelimbic area of the prefrontal cortex, broad areas of the somatosensory cortex, and the cerebellum. NSAE compared to SAE animals showed greater activation in the dorsal caudate-putamen and dorsal hippocampus. Seed correlation analysis revealed enhanced functional connectivity in SAE compared to NSAE animals between the prelimbic cortex and motor areas, as well as altered functional connectivity between midline cerebellum and sensorimotor regions. Our study provides the first evidence for functional brain reorganization following skilled aerobic exercise in Parkinsonian rats, and suggests that SAE compared to NSAE results in enhancement of prefrontal cortex- and cerebellum-mediated control of motor function. Copyright © 2015 Elsevier Inc. All rights reserved.
Wang, Zhuo; Guo, Yumei; Myers, Kalisa G.; Heintz, Ryan; Holschneider, Daniel P.
2015-01-01
Exercise modality and complexity play a key role in determining neurorehabilitative outcome in Parkinson’s disease (PD). Exercise training (ET) that incorporates both motor skill training and aerobic exercise has been proposed to synergistically improve cognitive and automatic components of motor control in PD patients. Here we introduced such a skilled aerobic ET paradigm in a rat model of dopaminergic deafferentation. Rats with bilateral, intra-striatal 6-hydroxydopamine lesions were exposed to forced ET for 4 weeks, either on a simple running wheel (non-skilled aerobic exercise, NSAE) or on a complex wheel with irregularly spaced rungs (skilled aerobic exercise, SAE). Cerebral perfusion was mapped during horizontal treadmill walking or at rest using [14C]-iodoantipyrine 1 week after the completion of ET. Regional cerebral blood flow (rCBF) was quantified by autoradiography and analyzed in 3-dimensionally reconstructed brains by statistical parametric mapping. SAE compared to NSAE resulted in equal or greater recovery in motor deficits, as well as greater increases in rCBF during walking in the prelimbic area of the prefrontal cortex, broad areas of the somatosensory cortex, and the cerebellum. NSAE compared to SAE animals showed greater activation in the dorsal caudate-putamen and dorsal hippocampus. Seed correlation analysis revealed enhanced functional connectivity in SAE compared to NSAE animals between the prelimbic cortex and motor areas, as well as altered functional connectivity between midline cerebellum and sensorimotor regions. Our study provides the first evidence for functional brain reorganization following skilled aerobic exercise in Parkinsonian rats, and suggests that SAE compared to NSAE results in enhancement of prefrontal cortex- and cerebellum-mediated control of motor function. PMID:25747184
Metabolic Rate and Ground Reaction Force During Motorized and Non-Motorized Treadmill Exercise
NASA Technical Reports Server (NTRS)
Everett, Meghan E.; Loehr, James A.; DeWitt, John K.; Laughlin, Mitzi; Lee, Stuart M. C.
2010-01-01
PURPOSE: To measure vertical ground reaction force (vGRF) and oxygen consumption (VO2) at several velocities during exercise using a ground-based version of the ISS treadmill in the M and NM modes. METHODS: Subjects (n = 20) walked or ran at 0.89, 1.34, 1.79, 2.24, 2.68, and 3.12 m/s while VO2 and vGRF data were collected. VO2 was measured using open-circuit spirometry (TrueOne 2400, Parvo-Medics). Data were averaged over the last 2 min of each 5-min stage. vGRF was measured in separate 15-s bouts at 125 Hz using custom-fitted pressure-sensing insoles (F-Scan Sport Sensors, Tekscan, Inc). A repeated-measures ANOVA was used to test for differences in VO2 and vGRF between M and NM and across speeds. Significance was set at P < 0.05. RESULTS: Most subjects were unable to exercise for 5 min at treadmill speeds above 1.79 m/s in the NM mode; however, vGRF data were obtained for all subjects at each speed in both modes. VO2 was approx.40% higher during NM than M exercise across treadmill speeds. vGRF increased with treadmill speed but was not different between modes. CONCLUSION: Higher VO2 with no change in vGRF suggests that the additional metabolic cost associated with NM treadmill exercise is accounted for in the horizontal forces required to move the treadmill belt. Although this may limit the exercise duration at faster speeds, high-intensity NM exercise activates the hamstrings and plantarflexors, which are not specifically targeted or well protected by other in-flight countermeasures.
Machado, Ísis Eloah; Pereira, Simone Cardoso Lisboa; Dias Júnior, Cláudio Santiago; Abreu, Mery Natali Silva; Borges, Angélica Marques; Filgueiras, Jullyane Hott
2014-05-01
The scope of this article is to assess the nutritional status of users of low-budget restaurants and soup kitchens in Belo Horizonte and to identify factors associated with being overweight. It involved a cross-sectional analytical study conducted among adults of both sexes in low-budget restaurants and soup kitchens in Belo Horizonte. Being overweight was the dependent variable and was defined as body mass index (BMI) ≥ 25 kg/m2. This was correlated with socio-demographic variables and the level of physical activity. The data were obtained directly through weight and height measurement and a semi-structured questionnaire. The study involved 1334 individuals, the majority being male. The prevalence of being overweight was 42.9% among the men and 45.8% among the women. The following factors were positively associated with being overweight: being older for both sexes; having a partner for the women; taking less physical exercise and higher socioeconomic level for the men. Detection of factors associated with being overweight reveals that there is a need to implement an effective systematic program of dietary and nutritional education in order to prevent and remedy this condition, so that low-budget restaurants fulfill their objective.
Pricing Employee Stock Options (ESOs) with Random Lattice
NASA Astrophysics Data System (ADS)
Chendra, E.; Chin, L.; Sukmana, A.
2018-04-01
Employee Stock Options (ESOs) are stock options granted by companies to their employees. Unlike standard options that can be traded by typical institutional or individual investors, employees cannot sell or transfer their ESOs to other investors. The sale restrictions may induce the ESO’s holder to exercise them earlier. In much cited paper, Hull and White propose a binomial lattice in valuing ESOs which assumes that employees will exercise voluntarily their ESOs if the stock price reaches a horizontal psychological barrier. Due to nonlinearity errors, the numerical pricing results oscillate significantly so they may lead to large pricing errors. In this paper, we use the random lattice method to price the Hull-White ESOs model. This method can reduce the nonlinearity error by aligning a layer of nodes of the random lattice with a psychological barrier.
NASA Technical Reports Server (NTRS)
Gundo, Dan
2003-01-01
Recently, I worked on creating a one-of-a-kind device for a Space Station group studying exercise physiology at another NASA Center. They approached my department at Ames Research Center to design and build an exercise bed that allowed users to perform the motions that they needed for ground-based research. The real challenge was that they needed the device designed, built, and delivered in just one month. The bed was intended to simulate doing squats while in a horizontal position as if on a moving sled. They wanted to incorporate a resistant device called an Interim Resistive Exercise Device (IRED), an adjustable cable tied into a reel to provide a measured amount of resistance. This device was used on the Station for exercising in space; we were taking the same resistant reel and incorporating it in this bed. In the early stages of a design project, I communicate with a customer as much as I can and as often as they will tolerate. There s a lot of learning that needs to go on, and I prefer to spend a little bit of extra time here because that can save a lot of time later. In the beginning, you need to volley the information back-and-forth, so that you understand the customer s requirements and they know what you re capable of doing.
Influence of bench angle on upper extremity muscular activation during bench press exercise.
Lauver, Jakob D; Cayot, Trent E; Scheuermann, Barry W
2016-01-01
This study compared the muscular activation of the pectoralis major, anterior deltoid and triceps brachii during a free-weight barbell bench press performed at 0°, 30°, 45° and -15° bench angles. Fourteen healthy resistance trained males (age 21.4 ± 0.4 years) participated in this study. One set of six repetitions for each bench press conditions at 65% one repetition maximum were performed. Surface electromyography (sEMG) was utilised to examine the muscular activation of the selected muscles during the eccentric and concentric phases. In addition, each phase was subdivided into 25% contraction durations, resulting in four separate time points for comparison between bench conditions. The sEMG of upper pectoralis displayed no difference during any of the bench conditions when examining the complete concentric contraction, however differences during 26-50% contraction duration were found for both the 30° [122.5 ± 10.1% maximal voluntary isometric contraction (MVIC)] and 45° (124 ± 9.1% MVIC) bench condition, resulting in greater sEMG compared to horizontal (98.2 ± 5.4% MVIC) and -15 (96.1 ± 5.5% MVIC). The sEMG of lower pectoralis was greater during -15° (100.4 ± 5.7% MVIC), 30° (86.6 ± 4.8% MVIC) and horizontal (100.1 ± 5.2% MVIC) bench conditions compared to the 45° (71.9 ± 4.5% MVIC) for the whole concentric contraction. The results of this study support the use of a horizontal bench to achieve muscular activation of both the upper and lower heads of the pectoralis. However, a bench incline angle of 30° or 45° resulted in greater muscular activation during certain time points, suggesting that it is important to consider how muscular activation is affected at various time points when selecting bench press exercises.
Guided bone regeneration in the treatment of periimplantitis.
Persson, L G; Ericsson, I; Berglundh, T; Lindhe, J
1996-12-01
The objective of the present experiment was to study the soft and hard tissue healing following treatment of experimentally induced periimplantitis. 5 labrador dogs about 1-year old were used. The mandibular right and left 1st molars, 4th and 3rd premolars were removed, titanium fixtures (Brånemark System) were installed, and standard abutments were connected in a 2nd stage procedure. After 3 months experimental periimplantitis was induced by the placement of cotton floss ligatures in a submarginal position. 6 weeks later the ligatures were removed. 1 month after ligature removal, an antibiotic regimen was initiated. During a 3-week period, each dog was given tablets of amoxicillin and metronidazole. In the left side of the mandible, buccal and lingual mucoperiosteal flaps were elevated and granulation tissue within the bone craters curetted. The abutments were removed. The exposed outer surfaces and the internal part of the fixtures were carefully cleaned with a detergent (delmopinol HC1). An e-PTFE membrane was placed over each fixture and adjusted to cover the bone crater. New cover screws were fitted through the membranes to the cleaned fixtures. The implants were submerged and the flaps sutured. In the right side of the mandible no local treatment was performed. The dogs were sacrificed after 4 months and biopsies prepared for histological examination. The findings indicated that treatment of a periimplantitis lesion, including comprehensive systemic antimicrobial therapy and cleaning of submerged implants resulted in (i) the elimination of the inflammatory process in the periimplant tissues and (ii) the establishment of a dense connective tissue capsule in direct contact with the previously exposed surface of the implant system. It was also observed that (iii) new bone was frequently laid down on the pristine cover screws.
Iraqui, O; Lakhssassi, N; Berrada, S; Merzouk, N
2016-06-01
The durability of dental implants depends on the presence of a 1mm coating bone sheath all around the fixture. Therefore, bone resorption represents a challenge for the practitioner. Bone expansion is a surgical technique that allows the management of horizontal bone atrophy. Cortical bone splitting allows for an enlargement of the residual crest by displacement of the vestibular bone flap. The immediate placement of implants secures the widening and allows for a 97% survival rate. However, bone expansion is hard to undertake in sites with high bone density. Furthermore, the use of traditional instruments increases patient's stress and the risk for an interruptive fracture during bone displacement. Non-traumatic bone expansion is one solution to this problem. The combination of piezo-surgery and conical expanders allows for a secured displacement of the selected bone flap as well as an immediate implant placement, avoiding the risk of slipping, overheating, or fracture, all within an undeniable operative comfort. Non-traumatic bone expansion is a reliable, reproducible, conservative, and economical in time and cost procedure. We describe our atraumatic bone expension and immediate implant placement technique in high bone density sites and illustrate it by a clinical case. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Nickel hydrogen cell tests. [recharging
NASA Technical Reports Server (NTRS)
Mueller, V. C.
1981-01-01
Some parametric tests followed by cycling tests are described for the characterization of the service life of nickel hydrogen cells. Three cells were automatically cycled in simulated low Earth orbit in 35 minute discharge, 55 minute charge, with charging voltage limited, temperature compensated. The cells were mounted in a fixture that conducts heat to an aluminum baseplate. The baseplate in turn, is bounded in a temperature controlled bath to remove the heat from the mounted fixture. One cell was tested with a zircar separator, which failed after 2473 cyles. Two other cells were tested one with a zircar separator; the other with asbestos. More than 400 cycles were achieved.
Method and apparatus for determining weldability of thin sheet metal
Goodwin, Gene M.; Hudson, Joseph D.
1988-01-01
A fixture is provided for testing thin sheet metal specimens to evaluate hot-cracking sensitivity for determining metal weldability on a heat-to-heat basis or through varying welding parameters. A test specimen is stressed in a first direction with a load selectively adjustable over a wide range and then a weldment is passed along over the specimen in a direction transverse to the direction of strain to evaluate the hot-cracking characteristics of the sheet metal which are indicative of the weldability of the metal. The fixture provides evaluations of hot-cracking sensitivity for determining metal weldability in a highly reproducible manner with minimum human error.
Solid-State Lighting Module (SSLM)
NASA Technical Reports Server (NTRS)
2008-01-01
The project's goal was to build a light-emitting-diode (LED)-based light fixture that is identical in fit, form, and function to the existing International Space Station (ISS) General Luminaire Assembly (GLA) light fixture and fly it on the ISS in early FY 2008 as a Station Detailed Test Objective (SDTO). Our design offers the following strengths: proven component hardware: Our design uses components flown in other KSC-developed hardware; heat path thermal pad: LED array heat is transferred from the circuit board by silicon pad, negating the need for a cooling fan; variable colorimetry: The output light color can be changed by inserting different LED combinations.
Autonomous berthing/unberthing of a Work Attachment Mechanism/Work Attachment Fixture (WAM/WAF)
NASA Technical Reports Server (NTRS)
Nguyen, Charles C.; Antrazi, Sami S.
1992-01-01
Discussed here is the autonomous berthing of a Work Attachment Mechanism/Work Attachment Fixture (WAM/WAF) developed by NASA for berthing and docking applications in space. The WAM/WAF system enables fast and reliable berthing (unberthing) of space hardware. A successful operation of the WAM/WAF requires that the WAM motor velocity be precisely controlled. The operating principle and the design of the WAM/WAF is described as well as the development of a control system used to regulate the WAM motor velocity. The results of an experiment in which the WAM/WAF is used to handle an orbital replacement unit are given.
Semiautomatic cold wire feeder systems increase GTA productivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, M.
1995-01-01
Often, the focus of attempts to increase GTA welding productivity is on studies to determine if justification exists for additional workstations, or for the investment in new fully automated dedicated welding fixtures. Often less costly and simpler solutions can bring about the necessary means to increase production rates and reduce operating costs. For short-run production applications, it is almost impossible to justify the substantial investment in a dedicated automatic fixture. Now, low cost GTA cold wire feeder systems are within the reach of even small shops. The paper views how cold wire equipment has been applied in several GTAW applicationsmore » to improve results.« less
2010-11-10
VANDENBERG AIR FORCE BASE, Calif. – In Building 1555 at Vandenberg Air Force Base in California, Orbital Sciences Corp. technicians connect the third stage of the Taurus XL rocket to the avionics of the temporary vehicle interface fixture. The fixture will come off once integrated with the encapsulated Glory spacecraft at the launch site. The Taurus XL rocket, targeted to lift off Feb. 23, 2011, from Vandenberg's Space Launch Complex 576-E, will take NASA's Glory satellite into low Earth. Glory is scheduled to collect data on the properties of aerosols and black carbon. It also will help scientists understand how the sun's irradiance affects Earth's climate. Photo credit: NASA/Randy Beaudoin, VAFB
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinke, R.G.; Mueller, C.; Knight, T.D.
1998-03-01
The computational fluid dynamics code CFX4.2 was used to evaluate steady-state thermal-hydraulic conditions in the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% of Title 1). Thirteen facility cases were evaluated with varying temperature dependence, drywell-array heat-source magnitude and distribution, location of the inlet tower, and no-flow curtains in the drywell-array vault. Four cases of a detailed model of the inlet-tower top fixture were evaluated to show the effect of the canopy-cruciform fixture design on the air pressure and flow distributions.
Measurement of upper extremity orientation by video stereometry system.
Peterson, B; Palmerud, G
1996-03-01
In the attempt to gain a broader understanding of the causal relationships behind work-related symptoms of pain in the human shoulder, monitoring of arm position is crucial. Different methods have been used with varying accuracy. A video-based stereometry system, using infra-red light and reflecting markers for motion analysis, has been introduced for measurements in the fields of ergonomics, biomechanics and sports medicine. The purpose of this study is to investigate the sources of error in using this system for posture registration of the upper limb. Measurements are performed on a calibration fixture, on a mechanical model of the upper limb and on a subject with an exoskeleton. Particular, attention is given to inconsistencies and relative errors due to the finite geometrical precision with which the markers are positioned in the calibration fixture and on the studied objects, the limited capability to align the objects relative to the coordinate system of the calibration fixture and the errors connected to angular measurements using protractors etc. It is concluded that the system makes a valuable addition to existing instruments for non-contact posture measurement, and produces position data with an adequate accuracy in normal handling.
NASA Astrophysics Data System (ADS)
Chacaltana, Oscar; Distler, Jacques; Trimm, Anderson; Zhu, Yinan
2018-05-01
We classify the class S theories of type E 7. These are four-dimensional N=2 superconformal field theories arising from the compactification of the E 7 (2, 0) theory on a punctured Riemann surface, C. The classification is given by listing all 3-punctured spheres ("fixtures"), and connecting cylinders, which can arise in a pants-decomposition of C. We find exactly 11,000 fixtures with three regular punctures, and an additional 48 with one "irregular puncture" (in the sense used in our previous works). To organize this large number of theories, we have created a web application at https://golem.ph.utexas.edu/class-S/E7/. Among these theories, we find 10 new ones with a simple exceptional global symmetry group, as well as a new rank-2 SCFT and several new rank-3 SCFTs. As an application, we study the strong-coupling limit of the E 7 gauge theory with 3 hypermultiplets in the 56. Using our results, we also verify recent conjectures that the T 2 compactification of certain 6 d (1, 0) theories can alternatively be realized in class S as fixtures in the E 7 or E 8 theories.
1999-02-23
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building's high bay, the Rotation Handling Fixture (RHF), with a simulated module attached, is viewed from above the altitude chamber into which it was lowered during a test. Under normal operation, the RHF will hold a pressurized module intended for the International Space Station, depositing it into the altitude chamber for leak testing. The chamber was recently reactivated after a 20-year hiatus. Originally, two chambers were built to test Apollo Program flight hardware. They were last used in 1975 during the Apollo-Soyuz Test Project. In 1997, in order to increase the probability of successful missions aboard the ISS, NASA decided to perform leak tests on ISS pressurized modules at the launch site. After installation of new vacuum pumping equipment and controls, a new control room, and a new rotation and handling fixture, the chamber again became operational in February 1999. The chamber, which is 33 feet in diameter and 50 feet tall, is constructed of stainless steel. The rotation handling fixture is aluminum. The first module that will be tested for leaks is the U.S. Laboratory. No date has been determined for the test
NASA-USRP Summer 2013 Internship Final Report
NASA Technical Reports Server (NTRS)
Gurganus, S. Christine
2013-01-01
Three major projects were undertaken during the Summer 2013 USRP Internship: (A) assisting the cTAPS group with component and pressure vessel system analyses and documentation, (B) designing a hoisting fixture for a solid rocket motor, (C) finding an alternative to removing the DOT rated gaseous nitrogen tank from the roof for hydrostatic testing. Hypergolic Material Assessments (HMAs) and pressure calculations were performed on components of pressure systems. Additionally, component information was logged in the Standard Parts Database to provide a location where system designers can find information regarding components, including their specifications and compatibility with fluids. A hoisting fixture was designed to hoist a solid rocket motor and meets the specifications related to stress and size. However, there are issues with the fixtures bolt head allotment, the bolt spacing, and the complexity of the part. Finally, calculations were performed on an expiring DOT rated gaseous nitrogen tank in an attempt to re-rate it per ASME standards. This was unsuccessful so other options are being explored for the tank. While much progress was made on all three projects, there is still work to be performed on each project to achieve the desired results.
Evaluation of a Highly Anticlastic Panel with Tow Overlaps
NASA Technical Reports Server (NTRS)
Wu, K. Chauncey; Gurdal, Zafer
2007-01-01
A rectangular, variable-stiffness panel with tow overlaps was manufactured using an advanced tow placement machine. The cured panel had large anticlastic imperfections, with measured amplitudes of over two times the average panel thickness. These imperfections were not due to the overall steered-fiber layup or the tow overlaps, but instead resulted from local asymmetries in the laminate that were caused by a manufacturing oversight. In the nominal panel layup, fiber angles vary linearly from 60 degrees on the panel axial centerline to 30 degrees on the parallel edges. A geometrically nonlinear analysis was performed with a -280 degree Fahrenheit thermal load to simulate the postcure cooldown to room temperature. The predicted geometric imperfections correlated well with the measured panel shape. Unique structural test fixtures were then developed which greatly reduced these imperfections, but they also caused prestresses in the panel. Surface imperfections measured after the panel was installed in the test fixtures were used with nonlinear finite element analyses to predict these fixturing-induced prestresses. These prestresses were also included in structural analyses of panel end compression to failure, and the analytical results compared well with test data when both geometric and material nonlinearities were included.
Fabrication of TiNi/CFRP smart composite using cold drawn TiNi wires
NASA Astrophysics Data System (ADS)
Xu, Ya; Otsuka, Kazuhiro; Toyama, Nobuyuki; Yoshida, Hitoshi; Jang, Byung-Koog; Nagai, Hideki; Oishi, Ryutaro; Kishi, Teruo
2002-07-01
In recent years, pre-strained TiNi shape memory alloys (SMA) have been used for fabricating smart structure with carbon fibers reinforced plastics (CFRP) in order to suppress microscopic mechanical damages. However, since the cure temperature of CFRP is higher than the reverse transformation temperatures of TiNi SMA, special fixture jigs have to be used for keeping the pre-strain during fabrication, which restricted its practical application. In order to overcome this difficulty, we developed a new method to fabricate SMA/CFRP smart composites without using special fixture jigs by controlling the transformation temperatures of SMA during fabrication. This method consists of using heavily cold-worked wires to increase the reverse transformation temperatures, and of using flash electrical heating of the wires after fabrication in order to decrease the reverse transformation temperatures to a lower temperature range again without damaging the epoxy resin around SMA wires. By choosing proper cold-working rate and composition of TiNi alloys, the reverse transformation temperatures were well controlled, and the TiNi/CFRP hybrid smart composite was fabricated without using special fixture jigs. The damage suppressing effect of cold drawn wires embedded in CFRP was confirmed.
Kumeria, Tushar; Wang, Joanna; Chan, Nicole; Harris, Todd J; Sailor, Michael J
2018-01-26
A porous photonic crystal is integrated with a plastic medical fixture (IV connector hub) to provide a visual colorimetric sensor to indicate the presence or absence of alcohol used to sterilize the fixture. The photonic crystal is prepared in porous silicon (pSi) by electrochemical anodization of single crystal silicon, and the porosity and the stop band of the material is engineered such that the integrated device visibly changes color (green to red or blue to green) when infiltrated with alcohol. Two types of self-reporting devices are prepared and their performance compared: the first type involves heat-assisted fusion of a freestanding pSi photonic crystal to the connector end of a preformed polycarbonate hub, forming a composite where the unfilled portion of the pSi film acts as the sensor; the second involves generation of an all-polymer replica of the pSi photonic crystal by complete thermal infiltration of the pSi film and subsequent chemical dissolution of the pSi portion. Both types of sensors visibly change color when wetted with alcohol, and the color reverts to the original upon evaporation of the liquid. The sensor performance is verified using E. coli-infected samples.
Park, Shin-Young; Kim, Kyoung-Hwa; Shin, Seung-Yun; Koo, Ki-Tae; Lee, Yong-Moo; Chung, Chong-Pyoung; Seol, Yang-Jo
2015-06-01
This study evaluated decontamination methods using a dental water jet and dental floss on microthreaded implants for regenerative periimplantitis therapy. In 6 beagle dogs, experimental periimplantitis was induced, and decontamination procedures, including manual saline irrigation (control group), saline irrigation using a dental water jet (group 1) and saline irrigation using a dental water jet with dental flossing (group 2), were performed. After in situ decontamination procedures, some of the implant fixtures (n = 4 per group) were retrieved for analysis by SEM, whereas other fixtures (n = 4 per group) underwent regenerative therapy. After 3 months of healing, the animals were killed. The SEM examination indicated that decontamination of the implant surfaces was the most effective in group 2, with no changes in implant surface morphology. The histological examination also revealed that group 2 achieved significantly greater amounts of newly formed bone (6.75 ± 2.19 mm; P = 0.018), reosseointegration (1.88 ± 1.79 mm; P = 0.038), and vertical bone fill (26.69 ± 18.42%; P = 0.039). Decontamination using a dental water jet and dental floss on microthreaded implants showed positive mechanical debridement effects and positive bone regeneration effects.
Zygomatic Implants: The Impact of Zygoma Bone Support on Biomechanics.
Romeed, Shihab; Malik, Raheel; Dunne, Stephen
2012-03-20
Abstract Maxillectomy and severely resorbed maxilla are challenging to restore with provision of removable prostheses. Dental implants are essential to restore aesthetics and function and subsequently quality of life in such group of patients. Zygomatic implants reduce the complications associated with bone grafting procedures and simplify the rehabilitation of atrophic maxilla and maxillectomy. The purpose of this study was to compare, by means of three-dimensional finite element analysis, the impact of different zygomatic bone support (10, 15, and 20mm) on the biomechanics of zygomatic implants. Results indicated maximum stresses within the fixture were increased by three times, when bone support decreased from 20 to 10mm, and concentrated at fixture/bone interface. However, stresses within the abutment screw and abutment itself were not significantly different regardless of the bone support level. Supporting bone at 10mm suffered double the stresses of 15 and 20mm. Fixture's deflection was decreased by two to three times when bone level support increased to 15mm and 20mm respectively. It was concluded that zygomatic bone support should not be less than 15mm and abutment screw is not at risk of fracture regardless of the zygomatic bone support.
Zygomatic implants: the impact of zygoma bone support on biomechanics.
Romeed, Shihab A; Malik, Raheel; Dunne, Stephen M
2014-06-01
Maxillectomy and severely resorbed maxilla are challenging to restore with provision of removable prostheses. Dental implants are essential to restore esthetics and function and subsequently quality of life in such group of patients. Zygomatic implants reduce the complications associated with bone grafting procedures and simplify the rehabilitation of atrophic maxilla and maxillectomy. The purpose of this study was to compare, by means of 3-dimensional finite element analysis, the impact of different zygomatic bone support (10, 15, and 20 mm) on the biomechanics of zygomatic implants. Results indicated that maximum stresses within the fixture were increased by 3 times when bone support decreased from 20 to 10 mm and were concentrated at the fixture/bone interface. However, stresses within the abutment screw and the abutment itself were not significantly different regardless of the bone support level. Supporting bone at 10 mm sustained double the stresses of 15 and 20 mm. Fixture's deflection was decreased by 2 to 3 times when bone support level increased to 15 mm and 20 mm, respectively. It was concluded that zygomatic bone support should not be less than 15 mm, and abutment screw is not at risk of fracture regardless of the zygomatic bone support.
NASA Astrophysics Data System (ADS)
Deng, Zhengping; Li, Shuanggao; Huang, Xiang
2018-06-01
In the assembly process of large-size aerospace products, the leveling and horizontal alignment of large components are essential prior to the installation of an inertial navigation system (INS) and the final quality inspection. In general, the inherent coordinate systems of large-scale coordinate measuring devices are not coincident with the geodetic horizontal system, and a dual-axis compensation system is commonly required for the measurement of difference in heights. These compensation systems are expensive and dedicated designs for different devices at present. Considering that a large-size assembly site usually needs more than one measuring device, a compensation approach which is versatile for different devices would be a more convenient and economic choice for manufacturers. In this paper, a flexible and cost-effective compensation method is proposed. Firstly, an auxiliary measuring device called a versatile compensation fixture (VCF) is designed, which mainly comprises reference points for coordinate transformation and a dual-axis inclinometer, and a kind of network tighten points (NTPs) are introduced and temporarily deployed in the large measuring space to further reduce transformation error. Secondly, the measuring principle of height difference is studied, based on coordinate transformation theory and trigonometry while considering the effects of earth curvature, and the coordinate transformation parameters are derived by least squares adjustment. Thirdly, the analytical solution of leveling uncertainty is analyzed, based on which the key parameters of the VCF and the proper deployment of NTPs are determined according to the leveling accuracy requirement. Furthermore, the proposed method is practically applied to the assembly of a large helicopter by developing an automatic leveling and alignment system. By measuring four NTPs, the leveling uncertainty (2σ) is reduced by 29.4% to about 0.12 mm, compared with that without NTPs.
Exercise-induced downbeat nystagmus in a Korean family with a nonsense mutation in CACNA1A.
Choi, Jae-Hwan; Seo, Jae-Deuk; Choi, Yu Ri; Kim, Min-Ji; Shin, Jin-Hong; Kim, Ji Soo; Choi, Kwang-Dong
2015-08-01
Episodic ataxia type 2 (EA2) is characterized by recurrent attacks of vertigo and ataxia lasting hours triggered by emotional stress or exercise. Although interictal horizontal gaze-evoked nystagmus and rebound nystagmus are commonly observed in patients with EA2, the nystagmus has been rarely reported during the vertigo attack. To better describe exercise-induced nystagmus in EA2, four affected members from three generations of a Korean family with EA2 received full neurological and neuro-otological evaluations. Vertigo was provoked in the proband with running for 10 min to record eye movements during the vertigo attack. We performed a polymerase chain reaction-based direct sequence analysis of all coding regions of CACNA1A in all participants. The four affected members had a history of exertional vertigo, imbalance, childhood epilepsy, headache, and paresthesia. The provocation induced severe vertigo and imbalance lasting several hours, and oculography documented pure downbeat nystagmus during the attack. Genetic analyses identified a nonsense mutation in exon 23 which has been registered in dbSNP as a pathogenic allele (c.3832C>T, p.R1278X) in all the affected members. Ictal downbeat nystagmus in the studied family indicates cerebellar dysfunction during the vertigo attack in EA2. In patients with episodic vertigo and ataxia, the observation of exercise-induced nystagmus would provide a clue for EA2.
Fixture for holding testing transducer
Wagner, T.A.; Engel, H.P.
A fixture for mounting an ultrasonic transducer against the end of a threaded bolt or stud to test the same for flaws. A base means threadedly secured to the side of the bolt has a rotating ring thereon. A post rising up from the ring (parallel to the axis of the workpiece) pivotally mounts a variable length cross arm, on the inner end of which is mounted the transducer. A spring means acts between the cross arm and the base to apply the testing transducer against the workpiece at a constant pressure. The device maintains constant for successive tests the radial and circumferential positions of the testing transducer and its contact pressure against the end of the workpiece.
Fixture for holding testing transducer
Wagner, Thomas A.; Engel, Herbert P.
1984-01-01
A fixture for mounting an ultrasonic transducer against the end of a threaded bolt or stud to test the same for flaws. A base means threadedly secured to the side of the bolt has a rotating ring thereon. A post rising up from the ring (parallel to the axis of the workpiece) pivotally mounts a variable length cross arm, on the inner end of which is mounted the transducer. A spring means acts between the cross arm and the base to apply the testing transducer against the workpiece at a constant pressure. The device maintains constant for successive tests the radial and circumferential positions of the testing transducer and its contact pressure against the end of the workpiece.
NASA Technical Reports Server (NTRS)
Britcher, Colin P.; Foster, Lucas E.
1994-01-01
A small-scale laboratory magnetic suspension system, the Large Angle Magnetic Suspension Test Fixture (LAMSTF) has been constructed at NASA Langley Research Center. This paper first presents some recent developments in the mathematical modelling of the system, particularly in the area of eddy current effects. It is shown that these effects are significant, but may be amenable to modelling and measurement. Next, a theoretical framework is presented, together with a comparison of computed and experimental data. Finally, some control aspects are discussed, together with illustration that the major design objective of LAMSTF - a controlled 360 deg rotation about the vertical axis, has been accomplished.
Periodontitis and periimplantitis: one and the same?
Meffert, R M
1993-12-01
Research shows that the same anaerobic, gram-negative pathogens are present in the periodontal and implant pocket or crevice. The implants in a partially edentulous case are probably more at risk due to the bacteria being more pathogenic and a seeding mechanism from the tooth pocket to the implant crevice. In the face of a normal microbial flora, retrograde periimplantitis or radiographic bone loss without gingival changes may be due to trauma because of overloading, loading too soon, and/or loading in a lateral direction. Finally, the combination of an infective process (periimplantitis) and noninfective or traumatic process (retrograde periimplantitis) will result in rapid osseous destruction and, possibly, loss of the implant fixture(s).
Exercise efficiency of low power output cycling.
Reger, M; Peterman, J E; Kram, R; Byrnes, W C
2013-12-01
Exercise efficiency at low power outputs, energetically comparable to daily living activities, can be influenced by homeostatic perturbations (e.g., weight gain/loss). However, an appropriate efficiency calculation for low power outputs used in these studies has not been determined. Fifteen active subjects (seven females, eight males) performed 14, 5-min cycling trials: two types of seated rest (cranks vertical and horizontal), passive (motor-driven) cycling, no-chain cycling, no-load cycling, cycling at low (10, 20, 30, 40 W), and moderate (50, 60, 80, 100, 120 W) power outputs. Mean delta efficiency was 57% for low power outputs compared to 41.3% for moderate power outputs. Means for gross (3.6%) and net (5.7%) efficiencies were low at the lowest power output. At low power outputs, delta and work efficiency values exceeded theoretical values. In conclusion, at low power outputs, none of the common exercise efficiency calculations gave values comparable to theoretical muscle efficiency. However, gross efficiency and the slope and intercept of the metabolic power vs mechanical power output regression provide insights that are still valuable when studying homeostatic perturbations. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lee, Jaejin; Kim, Dohyeon; Yu, Kyunghoon; Cho, Youngki; You, Joshua H
2018-01-01
Isometric cervical flexor system exercise (ICF) and isometric cervical extensor system exercise (ICE) are cervical stabilization techniques that have been used to restore cervical crossed syndrome (CCS)-associated forward head posture. However, the therapeutic effects and underlying motor control mechanisms remain elusive. The purpose of present study was investigating the concurrent therapeutic effects of ICF and ICE on muscle size, muscle imbalance ratio, and muscle recruitment sequence using ultrasound imaging and electromyography. A total of 18 participants (7 females; age=24±4.0 years) with CCS associated with forward head posture underwent ICF and ICE. Paired t-test analysis was used for statistical analysis. Paired t-test analysis showed that sternocleidomastoid thickness was greater during ICF than ICE. Similarly, cross-sectional area and horizontal thickness of the longus colli were greater during ICE than ICF. The upper trapezius/lower trapezius muscle imbalance ratio and the pectoralis major/lower trapezius muscle imbalance ratio were significantly decreased during the application of ICE compared to ICF. These results provide compelling, mechanistic evidence as to how ICE is more beneficial for the restoration of neuromuscular imbalance than ICF in individuals with CCS.
A method for monitoring intensity during aquatic resistance exercises.
Colado, Juan C; Tella, Victor; Triplett, N Travis
2008-11-01
The aims of this study were (i) to check whether monitoring of both the rhythm of execution and the perceived effort is a valid tool for reproducing the same intensity of effort in different sets of the same aquatic resistance exercise (ARE) and (ii) to assess whether this method allows the ARE to be put at the same intensity level as its equivalent carried out on dry land. Four healthy trained young men performed horizontal shoulder abduction and adduction (HSAb/Ad) movements in water and on dry land. Muscle activation was recorded using surface electromyography of 1 stabilizer and several agonist muscles. Before the final tests, the ARE movement cadence was established individually following a rhythmic digitalized sequence of beats to define the alternate HSAb/Ad movements. This cadence allowed the subject to perform 15 repetitions at a perceived exertion of 9-10 using Hydro-Tone Bells. After that, each subject performed 2 nonconsecutive ARE sets. The dry land exercises (1 set of HSAb and 1 set of HSAd) were performed using a dual adjustable pulley cable motion machine, with the previous selection of weights that allowed the same movement cadence to be maintained and the completion of the same repetitions in each of the sets as with the ARE. The average normalized data were compared for the exercises in order to determine possible differences in muscle activity. The results show the validity of this method for reproducing the intensity of effort in different sets of the same ARE, but is not valid for matching the same intensity level as kinematically similar land-based exercises.
Foot forces induced through Tai Chi push-hand exercises.
Wong, Shiu Hong; Ji, Tianjian; Hong, Youlian; Fok, Siu Lun; Wang, Lin
2013-08-01
The low impact forces of Tai Chi push-hand exercises may be particularly suited for older people and for those with arthritis; however, the biomechanics of push-hand exercises have not previously been reported. This paper examines the ground reaction forces (GRFs) and plantar force distributions during Tai Chi push-hand exercises in a stationary stance with and without an opponent. Ten male Tai Chi practitioners participated in the study. The GRFs of each foot were measured in three perpendicular directions using two force plates (Kistler). The plantar force distribution of each foot was measured concurrently using an insole sensor system (Novel). The results showed that the average maximum vertical GRF of each foot was not more than 88% ± 6.1% of the body weight and the sum of the vertical forces (103% ± 1.4%) generated by the two feet approximately equals the body weight at any one time. The horizontal GRFs generated by the two feet were in the opposite directions and the measured mean peak values were not more than 12% ± 2.8% and 17% ± 4.3% of the body weight in the medio-lateral and antero-posterior directions respectively. Among the nine plantar areas, the toes sustained the greatest plantar force. This study indicates that push-hand exercises generate lower vertical forces than those induced by walking, bouncing, jumping and Tai Chi gait, and that the greatest plantar force is located in the toe area, which may have an important application in balance training particularly for older adults.
Squat exercise biomechanics during short-radius centrifugation.
Duda, Kevin R; Jarchow, Thomas; Young, Laurence R
2012-02-01
Centrifuge-induced artificial gravity (AG) with exercise is a promising comprehensive countermeasure against the physiological de-conditioning that results from exposure to weightlessness. However, body movements onboard a rotating centrifuge are affected by both the gravity gradient and Coriolis accelerations. The effect of centrifugation on squat exercise biomechanics was investigated, and differences between AG and upright squat biomechanics were quantified. There were 28 subjects (16 male) who participated in two separate experiments. Knee position, foot reaction forces, and motion sickness were recorded during the squats in a 1-G field while standing upright and while supine on a horizontally rotating 2 m radius centrifuge at 0, 23, or 30 rpm. No participants terminated the experiment due to motion sickness symptoms. Total mediolateral knee deflection increased by 1.0 to 2.0 cm during centrifugation, and did not result in any injuries. There was no evidence of an increased mediolateral knee travel "after-effect" during postrotation supine squats. Peak foot reaction forces increased with rotation rate up to approximately 200% bodyweight (iRED on ISS provides approximately 210% bodyweight resistance). The ratio of left-to-right foot force throughout the squat cycle on the centrifuge was nonconstant and approximately sinusoidal. Total foot reaction force versus knee flexion-extension angles differed between upright and AG squats due to centripetal acceleration on the centrifuge. A brief exercise protocol during centrifugation can be safely completed without significant after-effects in mediolateral knee position or motion sickness. Several recommendations are made for the design of future centrifuge-based exercise protocols for in-space applications.
Plumbing Fixture for a Microfluidic Cartridge
NASA Technical Reports Server (NTRS)
Francis, Kevin
2007-01-01
A fixture has been devised for making the plumbing connections between a microfluidic device in a replaceable cartridge and an external fluidic system. The fixture includes a 0.25-in. (6.35-mm) thick steel plate, to which the cartridge is fastened by two 10-32 thumb screws. The plate holds one plumbing fitting for the inlet and one for the outlet of the microfluidic device. Each fitting includes a fused-silica tube of 0.006-in. (approx.0.15-mm) inside diameter within a fluorinated ethylene-propylene (FEP) tube of 0.0155-in. (approx.0.39-mm) inside diameter and 0.062- in. (approx.1.57-mm) outside diameter. The FEP tube is press-fit through the steel plate so that its exposed end is flush with the surface of the plate, and the silica tube protrudes 0.03 in. (approx.0.76 mm) from the plate/FEP-tube-end surface. The cartridge includes a glass cover plate that contains 0.06-mm-wide access ports. When the cartridge is fastened to the steel plate, the silica tubes become inserted through the access ports and into the body of the cartridge, while the ends of the FEP tubes become butted against the glass cover plate. An extremely tight seal is thereby made.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Tevis D. B., E-mail: tjacobs@pitt.edu; Wabiszewski, Graham E.; Goodman, Alexander J.
2016-01-15
The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tipmore » has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.« less
Pento, Robert; Marks, James E.; Staffanson, Clifford D.
2000-01-01
A thermoelectric module with a plurality of electricity generating units each having a first end and a second end, the units being arranged first end to second end along an in-line axis. Each unit includes first and second elements each made of a thermoelectric material, an electrically conductive hot member arranged to heat one side of the first element, and an electrically conductive cold member arranged to cool another side of the first element and to cool one side of the second element. The hot member, the first element, the cold member and the second element are supported in a fixture, are electrically connected respectively to provide an electricity generating unit, and are arranged respectively in positions along the in-line axis. The individual components of each generating unit and the respective generating units are clamped in their in-line positions by a loading bolt at one end of the fixture and a stop wall at the other end of the fixture. The hot members may have a T-shape and the cold members an hourglass shape to facilitate heat transfer. The direction of heat transfer through the hot members may be perpendicular to the direction of heat transfer through the cold members, and both of these heat transfer directions may be perpendicular to the direction of current flow through the module.
Bacterial plaque colonization around dental implant surfaces.
Covani, Ugo; Marconcini, Simone; Crespi, Roberto; Barone, Antonio
2006-09-01
To examine the distribution of bacteria into the internal and external surfaces of failed implants using histologic analysis. There were 10 failed pure titanium and 5 failed hydroxyapatite-coated titanium implants consecutively removed various years after their placement. Criteria for fixture removal were peri-implant radiolucency and clinical mobility. The mobile fixtures were retrieved with the patients under local anesthesia. Fixtures were removed maintaining the abutments with the aim to observe the bacterial infiltration at the level of abutment/implant interface and on the implant surface. A thin radiolucent space was always present around all the failed implants. The abutments screws were tightly secured in all clinical cases. The bacterial cells were composed of cocci and filaments, which were adherent to the implant surface with an orientation perpendicular to the long axis of the implant. All the specimens included in this study showed bacteria at the level of implant/abutment interface. Histologic analysis at the level of abutment/implant interface in 2-stage implants identified heavy bacterial colonization. These findings appear to support those studies showing bacteria penetration at the level of the micro-gap, which can legitimate the hypothesis that the micro-gap at the bone level could present a risk for bone loss caused by bacterial colonization.