Sample records for hplc system equipped

  1. 75 FR 47036 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-04

    ... Spectrometry (CS-MS) Systems, High Performance Liquid Chromatography (HPLC) Systems, Gas Chromatography Mass...-portable CS-MS, HPLC, GC-MS, and, ICP-MS Laboratory Equipment under PSC 6640 (Laboratory Equipment and...-portable equipment, SBA is limiting the waiver to not-portable CS-MS Systems, HPLC Systems, GC-MS Systems...

  2. Sustained Release Oral Nanoformulated Green Tea for Prostate Cancer Prevention

    DTIC Science & Technology

    2012-05-01

    31.25 ng/ml. The calibration samples were measured twice. The HPLC was a Shimadzu Prominence LC system containing a CBM-20A system controller...MDS SCIEX Ontario, Canada) equipped with a Turbo V Source and Turbo Ion Spray was coupled to the HPLC . The mass spectrometer was operated in...treated mice were subjected to HPLC and GC mass spectrometry for analysis of pharmacokinetic distribution of EGCG and bioavailability. Though we have

  3. Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine.

    PubMed

    Corrigan, Damion K; Salton, Neale A; Preston, Chris; Piletsky, Sergey

    2010-09-01

    Cleaning verification is a scientific and economic problem for the pharmaceutical industry. A large amount of potential manufacturing time is lost to the process of cleaning verification. This involves the analysis of residues on spoiled manufacturing equipment, with high-performance liquid chromatography (HPLC) being the predominantly employed analytical technique. The aim of this study was to develop a portable cleaning verification system for nelarabine using surface enhanced Raman spectroscopy (SERS). SERS was conducted using a portable Raman spectrometer and a commercially available SERS substrate to develop a rapid and portable cleaning verification system for nelarabine. Samples of standard solutions and swab extracts were deposited onto the SERS active surfaces, allowed to dry and then subjected to spectroscopic analysis. Nelarabine was amenable to analysis by SERS and the necessary levels of sensitivity were achievable. It is possible to use this technology for a semi-quantitative limits test. Replicate precision, however, was poor due to the heterogeneous drying pattern of nelarabine on the SERS active surface. Understanding and improving the drying process in order to produce a consistent SERS signal for quantitative analysis is desirable. This work shows the potential application of SERS for cleaning verification analysis. SERS may not replace HPLC as the definitive analytical technique, but it could be used in conjunction with HPLC so that swabbing is only carried out once the portable SERS equipment has demonstrated that the manufacturing equipment is below the threshold contamination level.

  4. The Effect of Acid Neutralization on Analytical Results Produced from SW846 Method 8330 after the Alkaline Hydrolysis of Explosives in Soil

    DTIC Science & Technology

    2012-09-01

    basic form of phosphoric acid or sodium phosphate NO2- Nitrite OH- Hydroxide ion ERDC/EL TR-12-14 1 1 Introduction Alkaline hydrolysis has...into amber sample vials and refrigerated until analyzed. TNT analyses were conducted by high performance liquid chromatography (HPLC) with a C-18...The explosives concentrations of the different soils were quantified using a DIONEX HPLC system equipped with a C-18 reverse phase column and a

  5. HPLC-Assisted Automated Oligosaccharide Synthesis: Implementation of the Autosampler as a Mode of the Reagent Delivery.

    PubMed

    Pistorio, Salvatore G; Nigudkar, Swati S; Stine, Keith J; Demchenko, Alexei V

    2016-10-07

    The development of a useful methodology for simple, scalable, and transformative automation of oligosaccharide synthesis that easily interfaces with existing methods is reported. The automated synthesis can now be performed using accessible equipment where the reactants and reagents are delivered by the pump or the autosampler and the reactions can be monitored by the UV detector. The HPLC-based platform for automation is easy to setup and adapt to different systems and targets.

  6. HPLC separation of triacylglycerol positional isomers on a polymeric ODS column.

    PubMed

    Kuroda, Ikuma; Nagai, Toshiharu; Mizobe, Hoyo; Yoshimura, Nobuhito; Gotoh, Naohiro; Wada, Shun

    2008-07-01

    A polymeric ODS column was applied to the resolution of triacylglycerol positional isomers (TAG-PI), i.e. 1,3-dioleoyl-2-palmitoyl-glycerol (OPO) and 1,2-dioleoyl-3-palmitoyl-rac-glycerol (OOP), with a recycle HPLC system. To investigate the ODS column species and the column temperatures for the resolution of a TAG-PI pair, a mixture of OPO and OOP was subjected to an HPLC system equipped with a non-endcapped polymeric, endcapped monomeric, endcapped intermediate, or non-endcapped monomeric ODS column at three different column temperatures (40, 25, or 10 degrees C). Only the non-endcapped polymeric ODS column achieved the separation of OPO and OOP, and the lowest column temperature (10 degrees C) showed the best resolution for them. The other pair of TAG-PI, a mixture of 1,3-dipalmitoyl-2-oleoyl-glycerol (POP) and 1,2-dipalmitoyl-3-oleoyl-rac-glycerol (PPO) was also subjected to the system equipped with a non-endcapped polymeric or monomeric ODS column at five different column temperatures (40, 32, 25, 17, and 10 degrees C). Thus, POP and PPO were also separated on only the non-endcapped polymeric ODS column at 25 degrees C. However, no clear peak appeared at 10 degrees C. These results would indicate that the polymeric ODS stationary phase has an ability to recognize the structural differences between TAG-PI pairs. Also, the column temperature is a very important factor for separating the TAG-PI pair, and the optimal temperature would relate to the solubility of TAG-PI in the mobile phase. Furthermore, the recycle HPLC system provided measurements for the separation and analysis of TAG-PI pairs.

  7. Characterization of Firing Range Soil from Camp Edwards, MA, and the Efficacy of Acid and Alkaline Hydrolysis for the Remediation of M1 105mm M67 Propellant

    DTIC Science & Technology

    2013-06-01

    method is intended for trace analysis of explosives and propellant residues by high performance liquid chromatography (HPLC) using an ultraviolet (UV...detector set at 254 nm. The HPLC used for this analysis was a Dionex Summit System with a UV detector equipped with Dionex E1 and E2 columns...Ca(OH)2) and sodium hydroxide (NaOH) were evaluated as sources of hydroxide ion for the alkaline hydrolysis of M1 propellant in soil from Camp

  8. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  9. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  10. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  11. Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

    NASA Technical Reports Server (NTRS)

    Carden, J. L.; Browner, R.

    1982-01-01

    The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

  12. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  13. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  14. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  15. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  16. 40 CFR 86.126-90 - Calibration of other equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... according to good practice. Specific equipment requiring calibration are the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and...

  17. 40 CFR 86.526-90 - Calibration of other equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... necessary according to good practice. Specific equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC...

  18. 40 CFR 86.126-90 - Calibration of other equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... according to good practice. Specific equipment requiring calibration are the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and...

  19. 40 CFR 86.526-90 - Calibration of other equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... necessary according to good practice. Specific equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC...

  20. Synthesis and Characterization of Liquid Crystalline Copolymethacrylates, Copolyacrylates and Copolysiloxanes Containing 4-Methoxy-4’-Hydroxy-alpha-Methylstilbene and 4-Hydroxy-4’-Methoxy-alpha-Methylstilbene Constitutional Isomers as Side Groups.

    DTIC Science & Technology

    1987-01-01

    oven, LC-600 autosampler, and Sigma 15 data station. High pressure liquid chromatography ( HPLC ) determinations were performed with the same...white crystals of 99.0% purity as determined by HPLC . m.p.=184-186*C (lit. 25, m.p.=182-1830C). ’H-NMR (DMSO-de, TMS, 6, ppm): 2.2 (s, -CHa), 6.7 (s, =CH...is about 99% ( HPLC ). HPLC equipped with UV detector, can not discriminate between the two isomers of MHMS. 200 MHz 1H-NMR spectra of sample A and

  1. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker.

    PubMed

    Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing

    2016-05-08

    Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.

  2. Immunoassay screening of lysergic acid diethylamide (LSD) and its confirmation by HPLC and fluorescence detection following LSD ImmunElute extraction.

    PubMed

    Grobosch, T; Lemm-Ahlers, U

    2002-04-01

    In all, 3872 urine specimens were screened for lysergic acid diethylamide (LSD) using the CEDIA DAU LSD assay. Forty-eight samples, mainly from psychiatric patients or drug abusers, were found to be LSD positive, but only 13 (27%) of these could be confirmed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD) following immunoaffinity extraction (IAE). Additional analysis for LSD using the DPC Coat-a-Count RIA was performed to compare the two immunoassay screening methods. Complete agreement between the DPC RIA assay and HPLC-FLD results was observed at concentrations below a cutoff concentration of 500 pg/mL. Samples that were LSD positive in the CEDIA DAU assay but not confirmed by HPLC-FLD were also investigated for interfering compounds using REMEDI HS drug-profiling system. REMEDI HS analysis identified 15 compounds (parent drugs and metabolites) that are believed to cross-react in the CEDIA DAU LSD assay: ambroxol, prilocaine, pipamperone, diphenhydramine, metoclopramide, amitriptyline, doxepine, atracurium, bupivacaine, doxylamine, lidocaine, mepivacaine, promethazine, ranitidine, and tramadole. The IAE/HPLC-FLD combination is rapid, easy to perform and reliable. It can reduce costs when standard, rather than more advanced, HPLC equipment is used, especially for labs that perform analyses for LSD infrequently. The chromatographic analysis of LSD, nor-LSD, and iso-LSD is not influenced by any of the tested cross-reacting compounds even at a concentration of 100 ng/mL.

  3. Quantity and quality of secoiridoids and lignans in extra virgin olive oils: the effect of two- and three-way decanters on Leccino and Raggiola olive cultivars.

    PubMed

    Antonini, Elena; Farina, Alfonso; Scarpa, Emanuele Salvatore; Frati, Alessandra; Ninfali, Paolino

    2016-01-01

    In this investigation, 14 extra virgin olive oils (EVOOs), produced with Leccino and Raggiola olive cultivars, by a new two-way (2W) decanter were compared with 14 EVOOs produced by means of a conventional three-way (3W) decanter. The 2W EVOOs had higher phenol concentrations, as shown by high-performance liquid chromatography/diode array detection (HPLC-DAD) analysis and yielded a higher extraction of the 3,4-DHPEA-EDA (oleacein), 3,4-DHPEA-EA (oleuropein aglycone) and p-HPEA-EDA (oleocanthal). The concentrations of lignans, (+)-pinoresinol and (+)-1-acetoxypinoresinol, detected by HPLC-FLD equipment, were higher in the 2W EVOOs than they were in EVOOs produced using the 3W system. Total phenols, detected by the Folin-Ciocalteu assay, were lower than those obtained by HPLC, but they significantly correlated (p < 0.05). The antioxidant capacity (ORAC) values of 2W EVOOs were higher than those of 3W EVOOs. In conclusion, the 2W system provided high-quality phenol EVOOs and became an indispensable tool when adverse climatic conditions reduced the olive secoiridoid concentration.

  4. Comparison of HPLC & spectrophotometric methods for estimation of antiretroviral drug content in pharmaceutical products.

    PubMed

    Hemanth Kumar, A K; Sudha, V; Swaminathan, Soumya; Ramachandran, Geetha

    2010-10-01

    Simple and reliable methods to estimate drugs in pharmaceutical products are needed. In most cases, antiretroviral drug estimations are performed using a HPLC method, requiring expensive equipment and trained technicians. A relatively simple and accurate method to estimate antiretroviral drugs in pharmaceutical preparations is by spectrophotometric method, which is cheap and simple to use as compared to HPLC. We undertook this study to standardise methods for estimation of nevirapine (NVP), lamivudine (3TC) and stavudine (d4T) in single tablets/capsules by HPLC and spectrophotometry and to compare the content of these drugs determined by both these methods. Twenty tablets/capsules of NVP, 3TC and d4T each were analysed for their drug content by HPLC and spectrophotometric methods. Suitably diluted drug solutions were run on HPLC fitted with a C18 column using UV detection at ambient temperature. The absorbance of the diluted drug solutions were read in a spectrophotometer at 300, 285 and 270 nm for NVP, 3TC and d4T respectively. Pure powders of the drugs were used to prepare calibration standards of known drug concentrations, which was set up with each assay. The inter-day variation (%) of standards for NVP, 3TC and d4T ranged from 2.5 to 6.7, 2.1 to 7.7 and 6.2 to 7.7, respectively by HPLC. The corresponding values by spectrophotometric method were 2.7 to 4.7, 4.2 to 7.2 and 3.8 to 6.0. The per cent variation between the HPLC and spectrophotometric methods ranged from 0.45 to 4.49 per cent, 0 to 4.98 per cent and 0.35 to 8.73 per cent for NVP, 3TC and d4T,respectively. The contents of NVP, 3TC and d4T in the tablets estimated by HPLC and spectrophotometric methods were similar, and the variation in the amount of these drugs estimated by HPLC and spectrophotometric methods was below 10 per cent. This suggests that the spectrophotometric method is as accurate as the HPLC method for estimation of NVP, 3TC and d4T in tablet/capsule. Hence laboratories that do not have HPLC equipment can also undertake these drug estimations using spectrophotometer.

  5. Identification and determination of flavonoids, carotenoids and chlorophyll concentration in Cynodon dactylon (L.) by HPLC analysis.

    PubMed

    Muthukrishnan, Saradha Devi; Kaliyaperumal, Ashokkumar; Subramaniyan, Annapoorani

    2015-01-01

    Cynodon dactylon (L.) is a potent medicinal plant in the traditional and current Indian medicinal systems. The objective of this research was to find out the levels of flavonoids, carotenoids and chlorophyll b in C. dactylon leaves by high-performance liquid chromatography (HPLC) equipped with a diode array detector. HPLC analysis revealed that total carotenoid and total flavonoid concentration were 62 mg/100 g and 249.1 μg/g, respectively. The mean chlorophyll b was 85.1 mg/100 g in C. dactylon. Among the flavonoids, quercetin (164.7 μg/g) was the major flavonoid followed by kaempferol (48.2 μg/g), rutin (18.4 μg/g), catechin (12.1 μg/g) and myricetin (5.7 μg/g). Of the carotenoids, β-carotene (35.2 mg/100 g) was predominant followed by lutein (17.0 mg/100 g), violaxanthin (5.8 mg/100 g) and zeaxanthin (4.2 mg/100 g). Chlorophyll b concentration was 85.1 mg/100 g in C. dactylon. The results of this investigation should be useful information for further pharmacological studies.

  6. Basic Research in Microplasmas

    DTIC Science & Technology

    2012-03-29

    concentrations of nitrate anions (NO3-) and nitrite anions (NO2-) in sterile water were measured with a high-performance liquid chromatography , HPLC ( Dionex ...ICS-2500 equipped with an ED50 electrochemical detector and a DIONEX ASRS 4-mm suppressor module). 25 μL samples were injected into the system for...the very few of He* atoms were used for the Penning ionization of the N2 molecule(reaction 6), because no N2 + ion (391nm) were detected in side-on

  7. Reverse phase high performance liquid chromatographic method development based on ultravioletvisible detector for the analysis of 1-hydroxypyrene (PAH biomarker) in human urine.

    PubMed

    Kamal, Atif; Gulfraz, Mohammad; Anwar, Mohammad Asad; Malik, Riffat Naseem

    2015-01-01

    1-hydroxypyrene is an important biomarker of exposure to polycyclic aromatic hydrocarbons (PAHs), which appears in the urine of exposed human subjects. In developing countries, where advanced instruments are not available, the importance of this biomarker demands convenient and sensitive methods for determination purposes. This study aimed at developing a methodology to quantify 1-hydroxypyrene (a biomarker of PAHs exposure) based on the UV-visible detector in the reverse phase high pressure liquid chromatography (HPLC). A 20 μl injection of sample was used for manual injection into the HPLC Shimadzu, equipped with the SPD-20 A UV-visible detector, the LC-20AT pump and the DGU-20A5 degasser. The C-18 column was used for the purpose of the analysis. The method showed a good linearity (the range: R2 = 0.979-0.989), and high detectability up to the nmol level. The average retention was 6.37, with the accuracy of 2%, and the percentage of recovery remained 108%. The overall performance of this method was comparable (in terms of detection sensitivity) and relatively better than previously reported studies using the HPLC system equipped with the UV-detector. This method is suitable and reliable for the detection/quantification of the 1-OHP in human urine samples, using the UV-detector, however, it is less sensitive as compared to the results of a florescence detector. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  8. Determination of the Antibiotic Oxytetracycline in Commercial Milk by Solid-Phase Extraction: A High-Performance Liquid Chromatography (HPLC) Experiment for Quantitative Instrumental Analysis

    ERIC Educational Resources Information Center

    Mei-Ratliff, Yuan

    2012-01-01

    Trace levels of oxytetracylcine spiked into commercial milk samples are extracted, cleaned up, and preconcentrated using a C[subscript 18] solid-phase extraction column. The extract is then analyzed by a high-performance liquid chromatography (HPLC) instrument equipped with a UV detector and a C[subscript 18] column (150 mm x 4.6 mm x 3.5 [mu]m).…

  9. Validation of a new point-of-care assay for determination of β-carotene concentration in bovine whole blood and plasma.

    PubMed

    Raila, Jens; Enjalbert, Francis; Mothes, Ralf; Hurtienne, Andrea; Schweigert, Florian J

    2012-03-01

    β-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. β-Carotene concentrations in plasma are used to optimize β-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure β-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring β-carotene in whole blood and plasma. β-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Concentrations of β-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean ± SD; n = 166): HPLC-plasma 4.23 ± 2.35 mg/L; POC-plasma 4.49 ± 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 ± 2.12 mg/L; POC-whole blood 3.67 ± 2.29 mg/L. Concentrations of β-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding β-carotene deficiency facilitates rapid and appropriate optimization of β-carotene supplementation in feed. © 2012 American Society for Veterinary Clinical Pathology.

  10. Ionization pattern obtained in electrospray ionization or atmospheric pressure chemical ionization interfaces for authorized antidepressants in Romania

    NASA Astrophysics Data System (ADS)

    Grecu, Iulia; Ionicǎ, Mihai; Vlǎdescu, Marian; Truţǎ, Elena; Sultan, Carmen; Viscol, Oana; Horhotǎ, Luminiţa; Radu, Simona

    2016-12-01

    Antidepressants were found in 1950. In the 1990s there was a new generation of antidepressants. They act on the level of certain neurotransmitters extrasinpatic by its growth. After their mode of action antidepressants may be: SSRIs (Selective Serotonin Reuptake Inhibitors); (Serotonin-Norepinephrine Reuptake Inhibitors); SARIs (Serotonin Antagonist Reuptake Inhibitors); NRIs (Norepinephrine Reuptake Inhibitors); NDRIs (Norepinephrine-Dopamine Reuptake Inhibitors) NDRAs (Norepinephrine-Dopamine Releasing Agents); TCAs (Tricyclic Antidepressants); TeCAs (Tetracyclic Antidepressants); MAOIs (Monoamine Oxidase Inhibitors); agonist receptor 5-HT1A (5- hydroxytryptamine); antagonist receptor 5-HT2; SSREs (Selective Serotonin Reuptake Enhancers) and Sigma agonist receptor. To determine the presence of antidepressants in biological products, it has been used a system HPLC-MS (High Performance Liquid Chromatography - Mass Spectrometry) Varian 12001. The system is equipped with APCI (Atmospheric Pressure Chemical Ionization) or ESI (ElectroSpray Ionization) interface. To find antidepressants in unknown samples is necessary to recognize them after mass spectrum. Because the mass spectrum it is dependent on obtaining private parameters work of HPLC-MS system, and control interfaces, the mass spectra library was filled with the mass spectra of all approved antidepressants in Romania. The paper shows the mass spectra obtained in the HPLCMS system.

  11. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    PubMed Central

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  12. Isolation and structural characterization of a novel sibutramine analogue, chlorosipentramine, in a slimming dietary supplement, by using HPLC-PDA, LC-Q-TOF/MS, FT-IR, and NMR.

    PubMed

    Yun, Jisuk; Shin, Kye Jung; Choi, Jangduck; Jo, Cheon-Ho

    2018-05-01

    A novel sibutramine analogue was detected in a slimming formula by high performance liquid chromatography with a photo diode detector array (HPLC-PDA). The unknown compound exhibited an ultraviolet (UV) spectrum that was similar to that of chlorosibutramine, despite having a different HPLC retention time. Further analysis of the slimming formula by LC-quadrupole time-of-flight mass spectrometry (LC-Q-TOF/MS) showed that the unknown compound had the formula C 18 H 27 Cl 2 N. To elucidate the structure of this new sibutramine analogue, the target compound in the slimming formula was isolated on a preparative-LC system equipped with a PDA. After analysis by fourier transform infrared (FT-IR) and nuclear magnetic resonance (NMR) spectroscopy, the unknown compound was identified as a sibutramine analogue in which the iso-butyl group on the side chain is replaced with an iso-pentyl group. This new sibutramine analogue was identified to be 1-(1-(3,4-dichlorophenyl)cyclobutyl)-N,N,4-trimethylpentan-1-amine and has been named as chlorosipentramine. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Steroids

    NASA Astrophysics Data System (ADS)

    Frey, Felix J.; Frey, Brigitte M.; Benet, Leslie Z.

    If a radioimmunoassay, a protein binding method, or a colorimetric assay for the assessment of a steroid level is replaced by high performance liquid chromatography (HPLC), the cost for the determination of a steroid level increases at least initially because one must acquire the new HPLC equipment. Therefore, if an older method provides the same results as the new, "advanced" HPLC method, the only advantage resulting from the introduction of a high performance chromatographic assay is that gained by the manufacturer in terms of greater sales. Thus, justification for the assessment of steroids by HPLC is only obtained if the quality and/or quantity of information gained is significantly increased as compared to that provided by the conventional methods. But this evidential relation, that more and better information justifies a higher price in any case, is no longer true in health care, with the birth some years ago of the categoric imperative for the reduction of costs in the medical sector. That is, each new technology introduced for health maintenance should demonstrate at least a stabilizing impact on total medical expenditures. Therefore, after reviewing the presently available HPLC methods for the clinically important steroids, we will consider whether HPLC analyses for these steroids can be recommended without violating this vox populi.

  14. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    PubMed

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  15. Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments.

    PubMed

    Akl, Magda A; Ahmed, Mona A; Ramadan, Ahmed

    2011-05-15

    In pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with extraction solution (50% water and 50% mobile phase), were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 91.12, 93.8 and 98.7% for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD), were below 1.5%. The method was validated over a concentration range of 1.15-6.92 μg ml(-1). Low quantities of drug residues were determined by HPLC-UV using a Hypersil ODS 5 μm (250×4.6 mm) at 50 °C with an acetonitrile:water:pH 7:pH 5 (39-55-5.5-0.5) mobile phase at flow rate of 1.5 ml min(-1), an injection volume of 20 μl and were detected at 254 nm. A simple, selective and sensitive HPLC-UV assay for the determination of ceftriaxone sodium residues on stainless steel surfaces was developed, validated and applied. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    PubMed Central

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  17. Dose-on-demand production of diverse 18F-radiotracers for preclinical applications using a continuous flow microfluidic system.

    PubMed

    Matesic, Lidia; Kallinen, Annukka; Greguric, Ivan; Pascali, Giancarlo

    2017-09-01

    The production of 18 F-radiotracers using continuous flow microfluidics is under-utilized due to perceived equipment limitations. We describe the dose-on-demand principle, whereby the back-to-back production of multiple, diverse 18 F-radiotracers can be prepared on the same day, on the same microfluidic system using the same batch of [ 18 F]fluoride, the same microreactor, the same HPLC column and SPE cartridge to obtain a useful production yield. [ 18 F]MEL050, [ 18 F]Fallypride and [ 18 F]PBR111 were radiolabeled with [ 18 F]fluoride using the Advion NanoTek Microfluidic Synthesis System. The outlet of the microreactor was connected to an automated HPLC injector and following the collection of the product, SPE reformulation produced the 18 F-radiotracer in <10% ethanolic saline. A thorough automated cleaning procedure was implemented to ensure no cross-contamination between radiotracer synthesis. The complete productions for [ 18 F]MEL050 and [ 18 F]Fallypride were performed at total flow rates of 20μL/min, resulting in 40±13% and 25±13% RCY respectively. [ 18 F]PBR111 was performed at 200μL/min to obtain 27±8% RCY. Molar activities for each 18 F-radiotracer were >100GBq/μmol and radiochemical purities were >97%, implying that the cleaning procedure was effective. Using the same initial solution of [ 18 F]fluoride, microreactor, HPLC column and SPE cartridge, three diverse 18 F-radiotracers could be produced in yields sufficient for preclinical studies in a back-to-back fashion using a microfluidic system with no detectable cross-contamination. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  18. Comprehensive hydrophilic interaction and ion-pair reversed-phase liquid chromatography for analysis of di- to deca-oligonucleotides.

    PubMed

    Li, Qin; Lynen, Frédéric; Wang, Jian; Li, Hanlin; Xu, Guowang; Sandra, Pat

    2012-09-14

    A comprehensive two-dimensional HPLC approach with a high degree of orthogonality was developed for analysis of di- to deca-oligonucleotides (ONs). Hydrophilic interaction liquid chromatography (HILIC) was used in the first dimension, and ion-pair reversed-phase liquid chromatography (IP-RPLC) was employed in the second dimension. The two dimensions were connected via a ten-port valve interface equipped with octadecyl silica (ODS) traps to immobilize and focus the ONs eluting from the first dimension prior to IP-RPLC separation. An aqueous make-up flow was used for effective trapping. The comprehensive two-dimensional HPLC system was optimized with a mixture consisting of 27 oligonucleotide standards. An overall chromatographic peak capacity of 500 was obtained. The use of the volatile buffer triethylamine acetate in the second dimension allowed straightforward coupling to electrospray ionization mass spectrometry (ESI-MS) and detection of each ON in the negative ionization mode. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Development and validation of a high performance liquid chromatographic method for simultaneous determination of vitamins A and D3 in fluid milk products.

    PubMed

    Chen, Yang; Reddy, Ravinder M; Li, Wenjing; Yettlla, Ramesh R; Lopez, Salvador; Woodman, Michael

    2015-01-01

    An HPLC method for simultaneous determination of vitamins A and D3 in fluid milk was developed and validated. Saponification and extraction conditions were studied for optimum recovery and simplicity. An RP HPLC system equipped with a C18 column and diode array detector was used for quantitation. The method was subjected to a single-laboratory validation using skim, 2% fat, and whole milk samples at concentrations of 50, 100, and 200% of the recommended fortification levels for vitamins A and D3 for Grade "A" fluid milk. The method quantitation limits for vitamins A and D3 were 0.0072 and 0.0026 μg/mL, respectively. Average recoveries between 94 and 110% and SD values ranging from 2.7 to 6.9% were obtained for both vitamins A and D3. The accuracy of the method was evaluated using a National Institute of Standards and Technology standard reference material (1849a) and proficiency test samples.

  20. Simultaneous determination of carbonyls and NO2 in exhausts of heavy-duty diesel trucks and transit buses by HPLC following 2,4-dinitrophenylhydrazine cartridge collection.

    PubMed

    Tang, Shida; Graham, Lisa; Shen, Ling; Zhou, Xianliang; Lanni, Thomas

    2004-11-15

    A method combining 2,4-dinitrophenylhydrazine (DNPH) cartridge sampling and high-performance liquid chromatography (HPLC) analysis has been used for the measurement of carbonyl and NO2 emissions from heavy-duty diesel trucks and transit buses. The reaction of NO2 with DNPH allows for the simultaneous and unambiguous determination of NO2 and carbonyl concentrations in exhaust samples. The potential coelution of the NO2-DNPH derivative with the formaldehyde-DNPH derivative under certain chromatographic conditions was investigated. Successful separation of these two species was achieved allowing for simultaneous determination of carbonyls and NO2 in the exhaust samples collected from heavy-duty diesel (HDD) trucks and diesel, diesel/electric hybrid, diesel equipped with the continuously regenerating technology (CRT) particle traps, and compressed natural gas (CNG) transit buses tested over various drive cycles. Elevated NO2 emissions from CRT-equipped buses were observed. The NO2/NOx volume ratios for HDD trucks and transit buses are discussed. A comparison of the DNPH derivatization with HPLC/UV-visible detection method with a chemiluminescence analyzer method for NO2 measurement is presented for a limited number of diesel/CRT and CNG buses.

  1. Simultaneous determination of chromones and coumarins in Radix Saposhnikoviae by high performance liquid chromatography with diode array and tandem mass detectors.

    PubMed

    Kim, Min Kyung; Yang, Dong-Hyug; Jung, Mihye; Jung, Eun Ha; Eom, Han Young; Suh, Joon Hyuk; Min, Jung Won; Kim, Unyong; Min, Hyeyoung; Kim, Jinwoong; Han, Sang Beom

    2011-09-16

    Methods using high performance liquid chromatography with diode array detection (HPLC-DAD) and tandem mass spectrometry (HPLC-MS/MS) were developed and validated for the simultaneous determination of 5 chromones and 6 coumarins: prim-O-glucosylcimifugin (1), cimifugin (2), nodakenin (3), 4'-O-β-d-glucosyl-5-O-methylvisamminol (4), sec-O-glucosylhamaudol (5), psoralen (6), bergapten (7), imperatorin (8), phellopterin (9), 3'-O-angeloylhamaudol (10) and anomalin (11), in Radix Saposhnikoviae. The separation conditions for HPLC-DAD were optimized using an Ascentis Express C18 (4.6 mm×100 mm, 2.7 μm particle size) fused-core column. The mobile phase was composed of 10% aqueous acetonitrile (A) and 90% acetonitrile (B) and the elution was performed under a gradient mode at a flow rate of 1.0 mL/min. The detection wavelength was set at 300 nm. The HPLC-DAD method yielded a base line separation of the 11 components in 50% methanol extract of Radix Saposhnikoviae with no interfering peaks detected. The HPLC-DAD method was validated in terms of linearity, accuracy and precision (intra- and inter-day), limit of quantification (LOQ), recovery, and robustness. Specific determination of the 11 components was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source. This HPLC-MS/MS method was also validated by determining the linearity, limit of quantification, accuracy, and precision. Quantification of the 11 components in 51 commercial Radix Saposhnikoviae samples was successfully performed using the developed HPLC-DAD method. The identity, batch-to-batch consistency, and authenticity of Radix Saposhnikoviae were successfully monitored by the proposed HPLC-DAD and HPLC-MS/MS methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. HPLC-ESI-QTOF-MS as a powerful analytical tool for characterising phenolic compounds in olive-leaf extracts.

    PubMed

    Quirantes-Piné, Rosa; Lozano-Sánchez, Jesús; Herrero, Miguel; Ibáñez, Elena; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2013-01-01

    Olea europaea L. leaves may be considered a cheap, easily available natural source of phenolic compounds. In a previous study we evaluated the possibility of obtaining bioactive phenolic compounds from olive leaves by pressurised liquid extraction (PLE) for their use as natural anti-oxidants. The alimentary use of these kinds of extract makes comprehensive knowledge of their composition essential. To undertake a comprehensive characterisation of two olive-leaf extracts obtained by PLE using high-performance liquid chromatography coupled to electrospray ionisation and quadrupole time-of-flight mass spectrometry (HPLC-ESI-QTOF-MS). Olive leaves were extracted by PLE using ethanol and water as extraction solvents at 150°C and 200°C respectively. Separation was carried out in a HPLC system equipped with a C₁₈-column working in a gradient elution programme coupled to ESI-QTOF-MS operating in negative ion mode. This analytical platform was able to detect 48 compounds and tentatively identify 31 different phenolic compounds in these extracts, including secoiridoids, simple phenols, flavonoids, cinnamic-acid derivatives and benzoic acids. Lucidumoside C was also identified for the first time in olive leaves. The coupling of HPLC-ESI-QTOF-MS led to the in-depth characterisation of the olive-leaf extracts on the basis of mass accuracy, true isotopic pattern and tandem mass spectrometry (MS/MS) spectra. We may conclude therefore that this analytical tool is very valuable in the study of phenolic compounds in plant matrices. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Determination of Tinopal CBS-X in rice papers and rice noodles using HPLC with fluorescence detection and LC-MS/MS.

    PubMed

    Ko, Kyung Yuk; Lee, Chae A; Choi, Jae Chon; Kim, Meehye

    2014-01-01

    To date there have been no reports of methods to determine Tinopal CBS-X. We developed a rapid and simple method to determine the Tinopal CBS-X content in rice noodles and rice papers using HPLC equipped with fluorescence detection. Heating the rice noodles and rice papers to 80°C after adding 75% methanol solution induced the release of Tinopal CBS-X from processed rice products. Tinopal CBS-X was separated using an isocratic mobile phase comprising 50% acetonitrile/water containing 0.4% tetrabutyl ammonium hydrogen sulphate at pH 8.0. The samples suspected to be positive by HPLC analysis were then confirmed by LC-MS/MS analysis. This study also investigated the Tinopal CBS-X content of three rice noodle products and two rice papers. The limits of quantification for rice papers and rice noodles were 1.58 and 1.51 µg kg(-1), respectively, and their correlation curves showed good linearity with r(2) ≥ 0.9997 and ≥ 0.9998, respectively. Moreover, rice papers had recoveries of 70.3-83.3% with precision ranging from 5.0% to 7.9%, whereas rice noodles had slightly lower recoveries of 63.4-78.7% and precisions of 8.5-11.5%. Only one rice noodle product contained Tinopal CBS-X, at around 2.1 mg kg(-1), whereas it was not detected in four other samples. Consequently, Tinopal CBS-X from rice noodles and rice papers can be successfully detected using the developed pre-treatment and ion-pairing HPLC system coupled with fluorescence detection.

  4. Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J; Kertesz, Vilmos

    RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI modemore » was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.« less

  5. Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection.

    PubMed

    Zhang, Kelly; Li, Yi; Tsang, Midco; Chetwyn, Nik P

    2013-09-01

    To overcome challenges in HPLC impurity analysis of pharmaceuticals, we developed an automated online multi-heartcutting 2D HPLC system with hyphenated UV-charged aerosol MS detection. The first dimension has a primary column and the second dimension has six orthogonal columns to enhance flexibility and selectivity. The two dimensions were interfaced by a pair of switching valves equipped with six trapping loops that allow multi-heartcutting of peaks of interest in the first dimension and also allow "peak parking." The hyphenated UV-charged aerosol MS detection provides comprehensive detection for compounds with and without UV chromophores, organics, and inorganics. It also provides structural information for impurity identification. A hidden degradation product that co-eluted with the drug main peak was revealed by RP × RP separation and thus enabled the stability-indicating method development. A poorly retained polar component with no UV chromophores was analyzed by RP × hydrophilic interaction liquid chromatography separation with charged aerosol detection. Furthermore, using this system, the structures of low-level impurities separated by a method using nonvolatile phosphate buffer were identified and tracked by MS in the second dimension. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Centrifugal partition chromatography: A preparative tool for isolation and purification of xylindein from Chlorociboria aeruginosa.

    PubMed

    Boonloed, Anukul; Weber, Genevieve L; Ramzy, Kelly M; Dias, Veronica R; Remcho, Vincent T

    2016-12-23

    A centrifugal partition chromatography (CPC) method was developed for the preparative-scale isolation and purification of xylindein from the wood-staining fungi, Chlorociboria aeruginosa. Xylindein, a blue-green pigment naturally secreted from the hyphae and fruiting bodies of the fungus, has great value in the decorative wood industry and textile coloration. Xylindein has great potential for use as a fluorescent labeling agent as well as in organic semiconductor applications. However, a primary limitation of xylindein is its poor solubility in most common HPLC solvents. Consequently, it is arduous to purify using preparative liquid chromatography or solid-phase extraction (SPE). Support-free, liquid-liquid chromatographic methods, including CPC, where solutes are separated based on their different distribution coefficients (K D ) between two immiscible solvent systems, are promising alternatives for the purification of the compound on a preparative scale. In this work, a new biphasic solvent system suitable for CPC separation of xylindein was developed. Various groups of solvents were assessed for their suitability as xylindein extractants. A new solvent system suitable for CPC separation of xylindein, composed of heptane/THF/MEK/acetonitrile/acetic acid/water, was developed. This solvent system yielded a K D value for xylindein of 1.54±0.04, as determined by HPLC (n=3). The compositions of the upper phase and lower phase of the solvent system were determined by Heteronuclear Single Quantum Correlation (HSQC) NMR and proton NMR. A CPC system, equipped with a fraction collector, was used for the isolation of xylindein from crude extracts. The xylindein fractions isolated by the CPC were then analyzed using HPLC and presented as a fractogram. Based on the CPC fractogram, the purified xylindein fractions were achieved after 30min CPC separation time, yielding 71% extraction efficiency. The developed CPC method allowed for isolation of this naturally sourced xylindein in amounts suitable for further study. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Simultaneous determination of five coumarins in Angelicae dahuricae Radix by HPLC/UV and LC-ESI-MS/MS.

    PubMed

    Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom

    2009-10-01

    Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.

  8. Industrial application of green chromatography--I. Separation and analysis of niacinamide in skincare creams using pure water as the mobile phase.

    PubMed

    Yang, Yu; Strickland, Zackary; Kapalavavi, Brahmam; Marple, Ronita; Gamsky, Chris

    2011-03-15

    In this work, chromatographic separation of niacin and niacinamide using pure water as the sole component in the mobile phase has been investigated. The separation and analysis of niacinamide have been optimized using three columns at different temperatures and various flow rates. Our results clearly demonstrate that separation and analysis of niacinamide from skincare products can be achieved using pure water as the eluent at 60°C on a Waters XTerra MS C18 column, a Waters XBridge C18 column, or at 80°C on a Hamilton PRP-1 column. The separation efficiency, quantification quality, and analysis time of this new method are at least comparable with those of the traditional HPLC methods. Compared with traditional HPLC, the major advantage of this newly developed green chromatography technique is the elimination of organic solvents required in the HPLC mobile phase. In addition, the pure water chromatography separations described in this work can be directly applied in industrial plant settings without further modification of the existing HPLC equipment. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Mallow carotenoids determined by high-performance liquid chromatography

    USDA-ARS?s Scientific Manuscript database

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  10. Quantification of the Triazole Antifungal Compounds Voriconazole and Posaconazole in Human Serum or Plasma Using Liquid Chromatography Electrospray Tandem Mass Spectrometry (HPLC-ESI-MS/MS).

    PubMed

    Molinelli, Alejandro R; Rose, Charles H

    2016-01-01

    Voriconazole and posaconazole are triazole antifungal compounds used in the treatment of fungal infections. Therapeutic drug monitoring of both compounds is recommended in order to guide drug dosing to achieve optimal blood concentrations. In this chapter we describe an HPLC-ESI-MS/MS method for the quantification of both compounds in human plasma or serum following a simple specimen preparation procedure. Specimen preparation consists of protein precipitation using methanol and acetonitrile followed by a cleanup step that involves filtration through a cellulose acetate membrane. The specimen is then injected into an HPLC-ESI-MS/MS equipped with a C18 column and separated over an acetonitrile gradient. Quantification of the drugs in the specimen is achieved by comparing the response of the unknown specimen to that of the calibrators in the standard curve using multiple reaction monitoring.

  11. The first use of a HPLC system at a Louisiana Sugarcane Factory: What it can do for you

    USDA-ARS?s Scientific Manuscript database

    Alma Plantation sugarcane factory established and operated the first High Performance Liquid Chromatography (HPLC) system in Louisiana in 2015. Although many HPLC systems exist, the factory opted for a ThermoFisherTM ion chromatography (anion exchange) system with integrated pulsed amperometric det...

  12. Matrix solid-phase dispersion technique for the determination of a new antiallergic drug, bilastine, in rat faeces.

    PubMed

    Berrueta, L A; Fernández-Armentia, M; Bakkali, A; Gonzalo, A; Lucero, M L; Orjales, A

    2001-08-25

    A matrix solid-phase dispersion (MSPD) procedure for the isolation and HPLC determination of a new antiallergic agent, bilastine, in rat faeces is presented. The effect on recovery of empirical variables such as nature, pH and volume of the washing and elution liquids and nature of the adsorbent has been tested. The best recoveries were attained using an octadecylsilyl sorbent, 10 ml of a 0.1 M NaHCO3-Na2CO3 aqueous buffer of pH 10.0 as washing solvent and 10 ml of methanol as elution solvent. The extracts were evaporated to dryness and reconstituted in mobile phase before their injection into a HPLC system, equipped with a Discovery RP-amide C16 column and a fluorescence detector. The method allows one to reach recoveries of 95.0% within the concentration range 0.05-10 microg/g, with within-day repeatabilities of less than 5% and between-day repeatabilities of less than 9% within this range. This method has been successfully applied to the excretion studies of bilastine in the rat.

  13. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; extraction of nitroaromatic compounds from water by polystyrene divinylbenzene cartridge and determination by high-performance liquid chromatography

    USGS Publications Warehouse

    Lindley, C.E.; Burkhardt, M.R.; DeRusseau, S.N.

    1994-01-01

    Organic explosives are determined in samples of ground water and surface water with emphasis on identifying and quantifying trinitrotoluene (TNT) metabolites. Water samples are filtered to remove suspended particulate material and passed through a polystyrene divinylbenzene-packed cartridge by a vacuum-extraction system. The target analytes subsequently are eluted with acetonitrile. A high-performance liquid chromatograph (HPLC) equipped with a photodiode-array detector is used for sample analysis. Analytes are separated on an octadecylsilane column using a methanol, water, and acetonitrile gradient elution. The compounds 2,4- and 2,6-dinitrotoluene are separated through an independent, isocratic elution. Method detection limits, on the basis of a 1-liter sample size, range from 0.11 to 0.32 microgram per liter. Recoveries averaged from 71 to 101 percent for 13 analytes in one set of HPLC-grade water fortified at about 1 microgram per liter. The method is limited to use by analysts experienced in handling explosive materials. (USGS)

  14. PHYSICAL AND CHEMICAL STABILITY ANALYSIS OF COSMETIC MULTI- PLE EMULSIONS LOADED WITH ASCORBYL PALMITATE AND SODIUM ASCORBYL PHOSPHATE SALTS.

    PubMed

    Khan, Hira; Akhtar, Naveed; Ali, Atif; Khan, Haji M Shoaib; Sohail, Muhammad; Naeem, Muhammad; Nawaz, Zarqa

    2016-09-01

    Stability of hydrophilic and lipophilic vitamin C derivatives for quenching synergistic antioxidant activities and to treat oxidative related diseases is a major issue. This study was aimed to encapsulate hydrophilic and lipophilic vitamin C derivatives (ascorbyl palmitate and sodium ascorbyl phosphate) as functional ingredients in a newly formulated multiple emulsion of the W//W type to attain the synergistic antioxidant effects and the resultant system's long term physical and chemical stability. Several multiple emulsions using the same concentration of emulsifiers but different concentrations of ascorbyl palmitate and sodium ascorbyl phosphate were developed. Three finally selected multiple emulsions (ME₁, ME₂ and ME₃) were evaluated for physical stability in terms of rheology, microscopy, conductivity, pH, and organoleptic characteristics under different storage conditions for 3 months. Chemical stability was determined by HPLC on Sykam GmbH HPLC system (Germany), equipped with a variable UV detector. Results showed that at accelerated storage conditions all the three multiple emulsions had shear thinning behavior of varying shear stress with no influence of location of functional ingredients in a carrier system. Conductivity values increased and pH values remained within the skin pH range for 3 months. Microscopic analysis showed an increase in globule size with the passage of time, especially at higher temperatures while decreased at low temperatures. Centrifugation test did not cause phase separation till the 45th day, but little effects after 2 months. Chemical stability analysis by HPLC at the end of 3 months showed that ascorbyl palmitate and sodium ascorbyl phosphate were almost stable in all multiple emulsions with no influence of their location in a carrier system. Multiple emulsions were found a stable carrier for hydrophilic and lipophilic vitamin C derivatives to enhance their desired effects. Considering that many topical formulations contain simple vitamin C it is suggested that present study may contribute to the development of more stable formulations with a combination of vitamin C derivatives to enhance their cosmetic benefits.

  15. Quantitative determination and sampling of azathioprine residues for cleaning validation in production area.

    PubMed

    Fazio, Tatiana Tatit; Singh, Anil Kumar; Kedor-Hackmann, Erika Rosa Maria; Santoro, Maria Inês Rocha Miritello

    2007-03-12

    Cleaning validation is an integral part of current good manufacturing practices in any pharmaceutical industry. Nowadays, azathioprine and several other pharmacologically potent pharmaceuticals are manufactured in same production area. Carefully designed cleaning validation and its evaluation can ensure that residues of azathioprine will not carry over and cross contaminate the subsequent product. The aim of this study was to validate simple analytical method for verification of residual azathioprine in equipments used in the production area and to confirm efficiency of cleaning procedure. The HPLC method was validated on a LC system using Nova-Pak C18 (3.9 mm x 150 mm, 4 microm) and methanol-water-acetic acid (20:80:1, v/v/v) as mobile phase at a flow rate of 1.0 mL min(-1). UV detection was made at 280 nm. The calibration curve was linear over a concentration range from 2.0 to 22.0 microg mL(-1) with a correlation coefficient of 0.9998. The detection limit (DL) and quantitation limit (QL) were 0.09 and 0.29 microg mL(-1), respectively. The intra-day and inter-day precision expressed as relative standard deviation (R.S.D.) were below 2.0%. The mean recovery of method was 99.19%. The mean extraction-recovery from manufacturing equipments was 83.5%. The developed UV spectrophotometric method could only be used as limit method to qualify or reject cleaning procedure in production area. Nevertheless, the simplicity of spectrophotometric method makes it useful for routine analysis of azathioprine residues on cleaned surface and as an alternative to proposed HPLC method.

  16. G-index: A new metric to describe dynamic refractive index effects in HPLC absorbance detection.

    PubMed

    Kraiczek, Karsten G; Rozing, Gerard P; Zengerle, Roland

    2018-09-01

    High performance liquid chromatography (HPLC) with a solvent gradient and absorbance detection is one of the most widely used methods in analytical chemistry. The observed absorbance baseline is affected by the changes in the refractive index (RI) of the mobile phase. Near the limited of detection, this complicates peak quantitation. The general aspects of these RI-induced apparent absorbance effects are discussed. Two different detectors with fundamentally different optics and flow cell concepts, a variable-wavelength detector equipped with a conventional flow cell and a diode-array detector equipped with a liquid core waveguide flow cell, are compared with respect to their RI behavior. A simple method to separate static - partly unavoidable - RI effects from dynamic RI effects is presented. It is shown that the dynamic RI behavior of an absorbance detector can be well described using a single, relatively easy-to-determine metric called the G-index. The G-index is typically in the order of a few seconds and its sign depends on the optical flow cell concept. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. [Examination related to revised test method for determination of formaldehyde, regulated by the law for the control of household products containing harmful substances].

    PubMed

    Ikarashi, Yoshiaki; Kaniwa, Masa-aki; Tsuchiya, Toshie

    2003-01-01

    In Japan, the amount of formaldehyde in textile products was regulated by the low for the control of household products containing harmful substances. Formaldehyde was determined by measuring the optical density of acetylacetone derivative of formaldehyde extracted from textiles. The household products low stated that the increase in the optical density of color development of the extract from the textile products for babies or infants within 24 months after birth should not be more than 0.05. Collaborative study decided the amount of formaldehyde equivalent to the increase in absorbance described above, and the amount was 16 ppm. There are some reports that formaldehyde causes an allergic reaction even at a very low concentration, so continuous regulation for formaldehyde in the textiles was desirable using this level of amount. We developed HPLC method for the determination of formaldehyde in textile products. Formaldehyde was determined by the direct injection of acetylacetone derivative of samples into the system equipped with ODS column and UV-VIS detector (detection wavelength 413 nm) using the mixture of acetonitrile and water as mobile phase. The linearity was obtained between a peak area or height and the concentrations of formaldehyde solution in the range of 0.0625-2 micrograms/ml. The regulation level was sufficiently detected by the present HPLC method. We recommended that the HPLC test was adopted as a reexamination method for the products may violate the regulation as well as a dimedone test.

  18. Highly sensitive copper fiber-in-tube solid-phase microextraction for online selective analysis of polycyclic aromatic hydrocarbons coupled with high performance liquid chromatography.

    PubMed

    Sun, Min; Feng, Juanjuan; Bu, Yanan; Luo, Chuannan

    2015-08-21

    A fiber-in-tube solid-phase microextraction (SPME) device was developed with copper wire and copper tube, which was served as both the substrate and sorbent with high physical strength and good flexibility. Its morphology and surface properties were characterized by scanning electron microscopy and energy dispersive X-ray spectrometry. It was coupled with high performance liquid chromatography (HPLC) equipment by replacing the sample loop of six-port injection valve, building the online SPME-HPLC system conveniently. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, extraction conditions including sampling rate, extraction time, organic content and desorption time were investigated and optimized. The copper fiber-in-tube exhibits excellent extraction efficiency toward PAHs, with enrichment factors from 268 to 2497. The established online SPME-HPLC method provides good linearity (0.05-100μgL(-1)) and low detection limits (0.001-0.01μgL(-1)) for PAHs. It has been used to determine PAHs in water samples, with recoveries in the range of 86.2-115%. Repeatability on the same extraction tube is in the range of 0.6-3.6%, and repeatability among three tubes is in the range of 5.6-20.1%. Compared with phthalates, anilines and phenols, the copper fiber-in-tube possesses good extraction selectivity for PAHs. The extraction mechanism is probably related to hydrophobic interaction and π-electron-metal interaction. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Simple HPLC method for detection of trace ephedrine and pseudoephedrine in high-purity methamphetamine.

    PubMed

    Makino, Yukiko

    2012-03-01

    A simple and sensitive HPLC technique was developed for the qualitative determination of ephedrine and pseudoephedrine (ephedrines), used as precursors of clandestine d-methamphetamine hydrochloride of high purity. Good separation of ephedrines from bulk d-methamphetamine was achieved, without any extraction or derivatization procedure on a CAPCELLPACK C18 MGII (250 × 4.6 mm) column. The mobile phase consisted of 50 mM KH2 PO4-acetonitrile (94:6 v/v %) using an isocratic pump system within 20 min for detecting two analytes. One run took about 50 min as it was necessary to wash out overloaded methamphetamine for column conditioning. The analytes were detected by UV absorbance measurement at 210 nm. A sample (20 mg) was simply dissolved in 1 mL of water, and a 50 μL aliquot of the solution was injected into the HPLC. The detection limits for ephedrine and pseudoephedrine in bulk d-methamphetamine were as low as 3 ppm each. This analytical separation technique made it possible to detect ephedrine and/or pseudoephedrine in seven samples of high-purity d-methamphetamine hydrochloride seized in Japan. The presence of trace ephedrines in illicit methamphetamine may strongly indicate a synthetic route via ephedrine in methamphetamine profiling. This method is simple and sensitive, requiring only commonly available equipment, and should be useful for high-purity methamphetamine profiling. Copyright © 2011 John Wiley & Sons, Ltd.

  20. 75 FR 38156 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-01

    ... Systems (CS-MS), High Performance Liquid Chromatography (HPLC) Systems, Gas Chromatography Mass... Chromatography (HPLC) Systems, Gas Chromatography Mass Spectrometry (GC-MS) Systems, and, Inductively Coupled...

  1. Binding patterns of vanadium ions with different valence states to human serum transferrin studied by HPLC/high-resolution ICP-MS.

    PubMed

    Nagaoka, Megumi Hamano; Yamazaki, Takeshi; Maitani, Tamio

    2002-09-06

    Vanadium (V) is an essential metal for mammals and has different valence states. In blood, V is bound to serum transferrin (Tf), a glycoprotein which has two metal-binding sites, and carbonate is generally required for the binding. In this study, the binding patterns of V(III), V(IV), and V(V) to human serum Tf (hTf) were analyzed using an HPLC system equipped with an anion-exchange column and directly connected to a high-resolution inductively coupled plasma-mass spectrometer for metal detection (51V). In affinity to hTf, the three ions were ranked V(III)>V(IV)>V(V) in the presence of bicarbonate and V(III) reverse congruent V(IV)>V(V) in the absence. Intermediates in the "open forms" binding to the respective sites were detected at the initial stage. V(IV) and V(V) were bound to the N-lobe site in the "closed form" and "open form," respectively. In the absence of bicarbonate, V ions with respective valence states were bound to hTf in the "open form." In terms of binding to hTf, tri-valent V was most favorable in the presence of bicarbonate.

  2. Degradation of Triazine-2-14C Metsulfuron–Methyl in Soil from an Oil Palm Plantation

    PubMed Central

    B. S., Ismail

    2015-01-01

    Triazine-2-14C metsulfuron–methyl is a selective, systemic sulfonylurea herbicide. Degradation studies in soils are essential for the evaluation of the persistence of pesticides and their breakdown products. The purpose of the present study was to investigate the degradation of triazine-2-14C metsulfuron–methyl in soil under laboratory conditions. A High Performance Liquid Chromatograph (HPLC) equipped with an UV detector and an on-line radio-chemical detector, plus a Supelco Discovery column (250 x 4.6 mm, 5 μm), and PRP–1 column (305 x 7.0 mm, 10 μm) was used for the HPLC analysis. The radioactivity was determined by a Liquid Scintillation Counter (LSC) in scintillation fluid. The soil used was both sterilized and non-sterilized in order to observe the involvement of soil microbes. The estimated DT50 and DT90 values of metsulfuron-methyl in a non-sterile system were observed to be 13 and 44 days, whereas in sterilized soil, the DT50 and DT90 were 31 and 70 days, respectively. The principal degradation product after 60 days was CO2. The higher cumulative amount of 14CO2 in 14C- triazine in the non-sterilized soil compared to that in the sterile system suggests that biological degradation by soil micro-organisms significantly contributes to the dissipation of the compound. The major routes of degradation were O-demethylation, sulfonylurea bridge cleavage and the triazine “ring-opened.” PMID:26437264

  3. Extraction and identification of flavonoids from parsley extracts by HPLC analysis

    NASA Astrophysics Data System (ADS)

    Stan, M.; Soran, M. L.; Varodi, C.; Lung, I.

    2012-02-01

    Flavonoids are phenolic compounds isolated from a wide variety of plants, and are valuable for their multiple properties, including antioxidant and antimicrobial activities. In the present work, parsley (Petroselinum crispum L.) extracts were obtained by three different extraction techniques: maceration, ultrasonic-assisted and microwave-assisted solvent extractions. The extractions were performed with ethanol-water mixtures in various ratios. From these extracts, flavonoids like the flavones apigenin and luteolin, and the flavonols quercetin and kaempferol were identified using an HPLC Shimadzu apparatus equipped with PDA and MS detectors. The separation method involved a gradient step. The mobile phase consisted of two solvents: acetonitrile and distilled water with 0.1% formic acid. The separation was performed on a RP-C18 column.

  4. Determination of 3-hydroxypropylmercapturic acid in urine by three column-switching high-performance liquid chromatography with electrochemical detection using a diamond electrode.

    PubMed

    Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko

    2017-09-29

    A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Phenolic compounds participating in mulberry juice sediment formation during storage.

    PubMed

    Zou, Bo; Xu, Yu-Juan; Wu, Ji-Jun; Yu, Yuan-Shan; Xiao, Geng-Sheng

    The stability of clarified juice is of great importance in the beverage industry and to consumers. Phenolic compounds are considered to be one of the main factors responsible for sediment formation. The aim of this study is to investigate the changes in the phenolic content in clarified mulberry juice during storage. Hence, separation, identification, quantification, and analysis of the changes in the contents of phenolic compounds, both free and bound forms, in the supernatant and sediments of mulberry juice, were carried out using high performance liquid chromatographic system, equipped with a photo-diode array detector (HPLC-PDA) and HPLC coupled with quadrupole-time of flight mass spectrometric (HPLC-QTOF-MS/MS) techniques. There was an increase in the amount of sediment formed over the period of study. Total phenolic content of supernatant, as well as free phenolic content in the extracts of the precipitate decreased, whereas the bound phenolic content in the sediment increased. Quantitative estimation of individual phenolic compounds indicated high degradation of free anthocyanins in the supernatant and sediment from 938.60 to 2.30 mg/L and 235.60 to 1.74 mg/g, respectively. A decrease in flavonoids in the supernatant was also observed, whereas the contents of bound forms of gallic acid, protocatechuic acid, caffeic acid, and rutin in the sediment increased. Anthocyanins were the most abundant form of phenolics in the sediment, and accounted for 67.2% of total phenolics after 8 weeks of storage. These results revealed that phenolic compounds, particularly anthocyanins, were involved in the formation of sediments in mulberry juice during storage.

  6. Microchip electrospray: improvements in spray and signal stability during gradient elution by an inverted postcolumn makeup flow.

    PubMed

    Jung, Stephanie; Effelsberg, Uwe; Tallarek, Ulrich

    2011-12-01

    Dynamic changes in mobile phase composition during high-performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray modes. We investigate the impact of the eluent composition on spray stability and MS response by infusion and injection experiments with a small tetrapeptide in water-acetonitrile mixtures. The employed HPLC/electrospray (ESI)-MS configuration uses a microchip equipped with an enrichment column, a separation column, and a makeup flow (MUF) channel. One nano pump is connected to the separation column, while a second one delivers solvent of exactly inverted composition to the MUF channel. Both solvent streams are united behind the separation column, before the ESI tip, such that the resulting electrosprayed solution always has identical composition during a gradient elution. Analyte peak parameters without and with MUF compensation are determined and discussed with respect to the electrospray mode and eluent composition. The postcolumn MUF significantly improves spray and signal stability over the entire solvent gradient, without compromising the performance of the HPLC separation column. It can also be conveniently implemented on microchip platforms.

  7. Identification of phenanthrene derivatives in Aerides rosea (Orchidaceae) using the combined systems HPLC-ESI-HRMS/MS and HPLC-DAD-MS-SPE-UV-NMR.

    PubMed

    Cakova, Veronika; Urbain, Aurélie; Antheaume, Cyril; Rimlinger, Nicole; Wehrung, Patrick; Bonté, Frédéric; Lobstein, Annelise

    2015-01-01

    In our continued efforts to contribute to the general knowledge on the chemical diversity of orchids, we have decided to focus our investigations on the Aeridinae subtribe. Following our previous phytochemical study of Vanda coerulea, which has led to the identification of phenanthrene derivatives, a closely related species, Aerides rosea Lodd. ex Lindl. & Paxton, was chosen for investigation. To identify new secondary metabolites, and to avoid isolation of those already known, by means of the combined systems HPLC-DAD(diode-array detector) with high-resolution tandem mass spectrometry (HRMS/MS) and HPLC-DAD-MS-SPE(solid-phase extraction)-UV-NMR. A dereplication strategy was developed using a HPLC-DAD-HRMS/MS targeted method and applied to fractions from A. rosea stem extract. Characterisation of unknown minor compounds was then performed using the combined HPLC-DAD-MS-SPE-UV-NMR system. The dereplication method allowed the characterisation of four compounds (gigantol, imbricatin, methoxycoelonin and coelonin), previously isolated from Vanda coerulea stem extract. The analyses of two fractions permitted the identification of five additional minor constituents including one phenanthropyran, two phenanthrene and two dihydrophenanthrene derivatives. The full set of NMR data of each compound was obtained from microgram quantities. Nine secondary metabolites were characterised in A. rosea stems, utilising HPLC systems combined with high-resolution analytical systems. Two of them are newly described phenanthrene derivatives: aerosanthrene (5-methoxyphenanthrene-2,3,7-triol) and aerosin (3-methoxy-9,10-dihydro-2,5,7-phenanthrenetriol). Copyright © 2014 John Wiley & Sons, Ltd.

  8. Identification of cardiac glycosides in fractions from Periploca forrestii by high-performance liquid chromatography/diode-array detection/electrospray ionization multi-stage tandem mass spectrometry and liquid chromatography/nuclear magnetic resonance.

    PubMed

    Li, Yong; Wu, Xianfu; Li, Jianbei; Wang, Yinghong; Yu, Shishan; Lv, Haining; Qu, Jing; Abliz, Zeper; Liu, Jing; Liu, Yuanyan; Du, Dan

    2010-02-01

    Cardiac glycosides are a class of naturally occurring compounds that are characterized by some interesting biological activities and are widely distributed in the plant kingdom and can also be found in some animals. There is an interest in the chemical characterization of these molecules due to their toxicity and their use in medicines. In the study reported here, a combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography equipped with diode-array detector (HPLC-DAD/ESI-MS(n)), and hyphenation to both liquid chromatography and nuclear magnetic resonance spectroscopy (HPLC/NMR) were utilized for the on-line analyses of cardiac glycosides from Periploca forrestii. The fragmentation patterns and (1)H NMR spectra of nine isolated cardiac glycosides were investigated; their fragmentation rules and (1)H NMR spectral characteristics were summarized and applied to the structural identification of similar constituents in fractions from P. forrestii. As a result, a total of nine trace cardiac glycosides were tentatively determined by analyses of accurate molecular masses, representative fragment ions and characteristic (1)H NMR signals provided by HPLC/high-resolution mass spectrometry (HRMS), HPLC-DAD/ESI-MS(n) and HPLC/(1)H NMR experiments, respectively. Of these, eight (2-9) are new compounds and one (1) is reported from P. forrestii for the first time. Results of the present study can benefit the rapid identification and targeted isolation of new cardiac glycosides from crude plant extracts. 2009 Elsevier B.V. All rights reserved.

  9. 40 CFR 86.109-94 - Exhaust gas sampling system; Otto-cycle vehicles not requiring particulate emission measurements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... detection for the HPLC analyzer. Sampling systems for all phases shall be identical. (iii) The methanol and... detection for the HPLC analyzer. Sampling systems for all phases shall be identical. (iii) The methanol and...

  10. 40 CFR 86.109-94 - Exhaust gas sampling system; Otto-cycle vehicles not requiring particulate emission measurements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... detection for the HPLC analyzer. Sampling systems for all phases shall be identical. (iii) The methanol and... detection for the HPLC analyzer. Sampling systems for all phases shall be identical. (iii) The methanol and...

  11. 40 CFR 86.109-94 - Exhaust gas sampling system; Otto-cycle vehicles not requiring particulate emission measurements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... detection for the HPLC analyzer. Sampling systems for all phases shall be identical. (iii) The methanol and... detection for the HPLC analyzer. Sampling systems for all phases shall be identical. (iii) The methanol and...

  12. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    PubMed

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins.

    PubMed

    Van Berkel, Gary J; Kertesz, Vilmos

    2013-06-30

    A continuous-flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by mass spectrometry. Demonstrated here is the on-line coupling of such a probe with high-performance liquid chromatography/mass spectrometry (HPLC/MS) enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. A continuous-flow liquid microjunction surface sampling probe was connected to a six-port, two-position valve for extract collection and injection to an HPLC column. A QTRAP® 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V™ ion source operated in positive electrospray ionization (ESI) mode was used for all experiments. The system operation was tested with the extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues, caffeine from a coffee bean, cocaine from paper currency, and proteins from dried sheep blood spots on paper. Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin α and β chains. Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous-flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  14. Development of an Acetate- or Sugar-fed Microbial Power Generator for Military Bases

    DTIC Science & Technology

    2012-07-01

    the U.S. military, which consumes 395,000 barrels of oil every day (Warner and Singer, 2009). Transport of fossil fuels to remote places in hostile... sOy ^ % (19%) ****** SP.(6%\\ ’ Soehngenia saccharolytica Geobocter sp. (14%) 11%) ^^ ^ Citrobacter 0</ £ -. sp...performance liquid chromatography (HPLC) equipped with BIORAD Aminex HPX-87H column for sugars and volatile acids analysis. Sucrose analysis employed water

  15. Paired-ion chromatography and high performance liquid chromatography of labetalol in feeds.

    PubMed

    Townley, E R; Ross, B

    1980-11-01

    A high performance liquid chromatographic (HPLC) method using reverse phase paired-ion chromatography and ultraviolet detection at 280 nm has been developed to determine labetalol, an alpha and beta adrenoceptor blocking agent, in Purina No. 5001 rodent chow. The method is simple and rapid, and demonstrates a separation technique applicable to other acidic and basic drugs. It requires only extraction of the drug with methanol--water--acetic acid (66 + 33 + 1) and separation of insoluble material by filtration before HPLC. Labetalol, is chromatographically separated from soluble feed components by means of a microBondapak C18 column and methanol--water--acetic acid (66 + 33 + 1) mobile phase, 0.005M with respect to sodium dioctylsulfosuccinate paired-ion reagent. Average recovery is 98.7% with a relative standard deviation of +/- 2.3% for the equipment described.

  16. Search for fullerenes in stone meteorites

    NASA Astrophysics Data System (ADS)

    Oester, M. Y.; Kuechl, D.; Sipiera, P. P.; Welch, C. J.

    1994-07-01

    The possibility of identifying fullerenes in stony meteorites became apparent from a paper given by Radicati de Brozolo. In this paper it was reported that fullerenes were present in the debris resulting from a collision between a micrometeoroid and an orbiting satellite. This fact generated sufficient curiosity to initiate a search for the presence of fullerenes in various stone meteorites. In the present study seven ordinary chondrites (al-Ghanim L6 (find), Dimmitt H4 (find), Lazbuddie LL5 (find), New Concord H5 (fall), Silverton H4 (find), Springlake L6 (find), and Umbarger L3/6 (find)). Four carbonaceous chondrites (ALH 83100 C2 (find), ALH 83108 C30 (find), Allende CV3 (fall), and Murchison CM2 (fall), and one achondrite (Monticello How (find)) were analyzed for the presence of fullerenes. The analytical procedure employed was as follows: 100 mg of meteorite was ground up with a mortar and pestle; 10 mL of toluene was then added and the mixture was refluxed for 90 min; this mixture was then filtered through a short column of silica; a 50 microliter sample was then analyzed by high pressure liquid chromatography (HPLC) using a Buckyclutcher I column with a mobile phase consisting of equal volumes of toluene and hexane at a flow rate of 1.00 mg per minute, with detection at 330 and 600 nm. Three of the meteorites, Allende, Murchison, and al-Ghanim, gave HPLC traces containing peaks with similar retention times to the HPLC trace of an authentic fullerene C60. However, further analysis using an HPLC instrument equipped with a diode-array detector failed to confirm any of the substances detected in the three meteorites as C60. Additional analyses will be conducted to identify what the HPLC traces actually represent.

  17. Method optimization and quality assurance in speciation analysis using high performance liquid chromatography with detection by inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Larsen, Erik H.

    1998-02-01

    Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.

  18. Current HPLC Methods for Assay of Nano Drug Delivery Systems.

    PubMed

    Tekkeli, Serife Evrim Kepekci; Kiziltas, Mustafa Volkan

    2017-01-01

    In nano drug formulations the mechanism of release is a critical process to recognize controlled and targeted drug delivery systems. In order to gain high bioavailability and specificity from the drug to reach its therapeutic goal, the active substance must be loaded into the nanoparticles efficiently. Therefore, the amount in biological fluids or tissues and the remaining amount in nano carriers are very important parameters to understand the potential of the nano drug delivery systems. For this aim, suitable and validated quantitation methods are required to determine released drug concentrations from nano pharmaceutical formulations. HPLC (High Performance Liquid Chromatography) is one of the most common techniques used for determination of released drug content out of nano drug formulations, in different physical conditions, over different periods of time. Since there are many types of HPLC methods depending on detector and column types, it is a challenge for the researchers to choose a suitable method that is simple, fast and validated HPLC techniques for their nano drug delivery systems. This review's goal is to compare HPLC methods that are currently used in different nano drug delivery systems in order to provide detailed and useful information for researchers. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  19. KENNEDY SPACE CENTER, FLA. -- Lanfang Levine, with Dynamac Corp., helps install a Dionex DX-500 IC/HPLC system in the Space Life Sciences Lab. The equipment will enable analysis of volatile compounds, such as from plants. The 100,000 square-foot facility houses labs for NASA’s ongoing research efforts, microbiology/microbial ecology studies and analytical chemistry labs. Also calling the new lab home are facilities for space flight-experiment and flight-hardware development, new plant growth chambers, and an Orbiter Environment Simulator that will be used to conduct ground control experiments in simulated flight conditions for space flight experiments. The SLS Lab, formerly known as the Space Experiment Research and Processing Laboratory or SERPL, provides space for NASA’s Life Sciences Services contractor Dynamac Corporation, Bionetics Corporation, and researchers from the University of Florida. NASA’s Office of Biological and Physical Research will use the facility for processing life sciences experiments that will be conducted on the International Space Station. The SLS Lab is the magnet facility for the International Space Research Park at KSC being developed in partnership with Florida Space Authority.

    NASA Image and Video Library

    2004-01-05

    KENNEDY SPACE CENTER, FLA. -- Lanfang Levine, with Dynamac Corp., helps install a Dionex DX-500 IC/HPLC system in the Space Life Sciences Lab. The equipment will enable analysis of volatile compounds, such as from plants. The 100,000 square-foot facility houses labs for NASA’s ongoing research efforts, microbiology/microbial ecology studies and analytical chemistry labs. Also calling the new lab home are facilities for space flight-experiment and flight-hardware development, new plant growth chambers, and an Orbiter Environment Simulator that will be used to conduct ground control experiments in simulated flight conditions for space flight experiments. The SLS Lab, formerly known as the Space Experiment Research and Processing Laboratory or SERPL, provides space for NASA’s Life Sciences Services contractor Dynamac Corporation, Bionetics Corporation, and researchers from the University of Florida. NASA’s Office of Biological and Physical Research will use the facility for processing life sciences experiments that will be conducted on the International Space Station. The SLS Lab is the magnet facility for the International Space Research Park at KSC being developed in partnership with Florida Space Authority.

  20. Pressurized planar electrochromatography, high-performance thin-layer chromatography and high-performance liquid chromatography--comparison of performance.

    PubMed

    Płocharz, Paweł; Klimek-Turek, Anna; Dzido, Tadeusz H

    2010-07-16

    Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 microm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones. 2010 Elsevier B.V. All rights reserved.

  1. Method development in high-performance liquid chromatography for high-throughput profiling and metabonomic studies of biofluid samples.

    PubMed

    Pham-Tuan, Hai; Kaskavelis, Lefteris; Daykin, Clare A; Janssen, Hans-Gerd

    2003-06-15

    "Metabonomics" has in the past decade demonstrated enormous potential in furthering the understanding of, for example, disease processes, toxicological mechanisms, and biomarker discovery. The same principles can also provide a systematic and comprehensive approach to the study of food ingredient impact on consumer health. However, "metabonomic" methodology requires the development of rapid, advanced analytical tools to comprehensively profile biofluid metabolites within consumers. Until now, NMR spectroscopy has been used for this purpose almost exclusively. Chromatographic techniques and in particular HPLC, have not been exploited accordingly. The main drawbacks of chromatography are the long analysis time, instabilities in the sample fingerprint and the rigorous sample preparation required. This contribution addresses these problems in the quest to develop generic methods for high-throughput profiling using HPLC. After a careful optimization process, stable fingerprints of biofluid samples can be obtained using standard HPLC equipment. A method using a short monolithic column and a rapid gradient with a high flow-rate has been developed that allowed rapid and detailed profiling of larger numbers of urine samples. The method can be easily translated into a slow, shallow-gradient high-resolution method for identification of interesting peaks by LC-MS/NMR. A similar approach has been applied for cell culture media samples. Due to the much higher protein content of such samples non-porous polymer-based small particle columns yielded the best results. The study clearly shows that HPLC can be used in metabonomic fingerprinting studies.

  2. 40 CFR 86.542-90 - Records required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... formaldehyde sampling system. (6) The formaldehyde calibration information from the HPLC standards. (7) The concentration of the HPLC analysis of the test sample (formaldehyde). (q) Additional required records for...

  3. 40 CFR 86.542-90 - Records required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... formaldehyde sampling system. (6) The formaldehyde calibration information from the HPLC standards. (7) The concentration of the HPLC analysis of the test sample (formaldehyde). (q) Additional required records for...

  4. 40 CFR 86.542-90 - Records required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... formaldehyde sampling system. (6) The formaldehyde calibration information from the HPLC standards. (7) The concentration of the HPLC analysis of the test sample (formaldehyde). (q) Additional required records for...

  5. 40 CFR 86.542-90 - Records required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... formaldehyde sampling system. (6) The formaldehyde calibration information from the HPLC standards. (7) The concentration of the HPLC analysis of the test sample (formaldehyde). (q) Additional required records for...

  6. Development and validation of a quick, easy, cheap, effective, rugged and safe method for the determination of imidacloprid and its metabolites in soil.

    PubMed

    Akoijam, Romila; Singh, Balwinder; Mandal, Kousik

    2015-04-01

    A simplified quick, easy, cheap, effective, rugged and safe method was standardized and validated for the estimation of residues of imidacloprid and its metabolites from different types of soil comprising sandy loam, loamy sand and clay loam soil. The samples were extracted with acetonitrile, clean up by treatment with primary secondary amine sorbent and graphitized carbon. High-performance liquid chromatography (HPLC) is a technique to separate and quantitate residues of polar, nonvolatile and thermolabile chemical compounds, using high-pressure pumps, short and narrow columns packed with microparticulate phases and a detector. The residues were estimated using HPLC equipped with a photodiode array detector system, C18 column. Acetonitrile and water (30 : 70) were used as an isocratic mobile phase at 0.3 mL/min. Imidacloprid and its metabolites presented distinct peaks at retention factors of 4.93 min (6-chloronicotinic acid), 7.91 min (nitroguanidine), 9.12 min (olefin), 11.32 min (nitrosimine), 13.82 min (urea), 15.45 min (5-hydroxy) and 22.47 min (imidacloprid). Consistent recoveries above 80% for imidacloprid and its metabolites were observed when samples were spiked at 0.01, 0.05 and 0.10 mg/kg levels. The limit of quantification of the method was 0.01 mg/kg. The analytical method was validated in terms of parameters including selectivity, linearity, precision and accuracy of the detection system. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Advanced liquid chromatography-mass spectrometry interface based on electron ionization.

    PubMed

    Cappiello, A; Famiglini, G; Pierini, E; Palma, P; Trufelli, H

    2007-07-15

    Major progress in interfacing liquid chromatography and electron ionization mass spectrometry is presented. The minimalism of the first prototype, called the Direct-EI interface, has been widely refined, improved, and applied to modern instrumentation. The simple interfacing principle is based on the straight connection between a nanoHPLC system and a mass spectrometer equipped with an EI source forming a solid and reliable unicum resembling the immediacy and straightforwardness of GC/MS. The interface shows a superior performance in the analysis of small-medium molecular weight compounds, especially when compared to its predecessors, and a unique trait that excels particularly in the following aspects: (1) It delivers high-quality, fully library matchable mass spectra of most sub-1 kDa molecules amenable by HPLC. (2) It is a chemical ionization free interface (unless operated intentionally) with accurate reproduction of the expected isotope ion abundances. (3) Response is never influenced by matrix components in the sample or in the mobile phase (nonvolatile salts are also well accepted). A deep evaluation of these aspects is presented and discussed in detail. Other characteristics of the interface performance such as limits of detections, range of linear response, and intra- and interday signal stability were also considered. The usefulness of the interface has been tested in a few real-world applications where matrix components played a detrimental role with other LC/MS techniques.

  8. Constant pressure mode extended simple gradient liquid chromatography system for micro and nanocolumns.

    PubMed

    Šesták, Jozef; Kahle, Vladislav

    2014-07-11

    Performing gradient liquid chromatography at constant pressure instead of constant flow rate has serious potential for shortening the analysis time and increasing the productivity of HPLC instruments that use gradient methods. However, in the constant pressure mode the decreasing column permeability during a long period of time negatively affects the repeatability of retention time. Thus a volume-based approach, in which the detector signal is plotted as a function of retention volume, must be taken into consideration. Traditional HPLC equipment, however, requires quite complex hardware and software modifications in order to work at constant pressure and in the volume-based mode. In this short communication, a low cost and easily feasible pressure-controlled extension of the previously described simple gradient liquid chromatography platform is proposed. A test mixture of four nitro esters was separated by 10-60% (v/v) acetone/water gradient and a high repeatability of retention volumes at 20MPa (RSD less than 0.45%) was realized. Separations were also performed at different values of pressure (20, 25, and 31MPa), and only small variations of the retention volumes (up to 0.8%) were observed. In this particular case, the gain in the analysis speed of 7% compared to the constant flow mode was realized at a constant pressure. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. In vitro production of gymnemic acid from Gymnema sylvestre (Retz) R. Br. ex roemer and schultes through callus culture under abiotic stress conditions.

    PubMed

    Ali Ahmed, Abdul Bakrudeen; Rao, Adhikarla Suryanarayana; Rao, Mandali Venkateswara

    2009-01-01

    Plant secondary metabolites have enormous potential for research and new drug development. Many secondary metabolites have a complex and unique structure and their production is often enhanced by biotic and abiotic stress conditions. Gymnemic acid (C(43)H(68)O(14)), a pentacyclic triterpenoid isolated from the leaves of Gymnema sylvestre, exhibits potent inhibitory effect on diabetes. The gymnemic acid content is determined by chromatographic methods: Camag HPTLC system equipped with a sample applicator Linomat IV and TLC scanner and integration software CAT 4.0. In HPLC C(18) (ODS) reverse phase column; water 486 UV detector; mobile phase, water/methanol (35:65, HPLC grade) + 0.1% acetic acid are used. Sample (20 microL) is applied with a flow rate of 1 mL/min and read at 230 nm with UV detector. The production of gymnemic acid is significantly higher in callus treated with 2,4-dichloro phenoxy acetic acid (2,4-D) and kinetin (KN). The blue light increases gymnemic acid accumulation upto 4.4-fold as compared with fluorescent light treatment and out of which 2.8 is found in leaves. Gymnemic acid is isolated from callus, grown under stress conditions followed by preparative TLC, simple and reproducible character based on HPTLC and high performance liquid chromatography.

  10. Electrophoretic deposition of graphene oxide onto carbon fibers for in-tube solid-phase microextraction.

    PubMed

    Feng, Juanjuan; Wang, Xiuqin; Tian, Yu; Bu, Yanan; Luo, Chuannan; Sun, Min

    2017-09-29

    Carbon fibers (CFs) were functionalized with graphene oxide (GO) by an electrophoretic deposition (EPD) method for in-tube solid-phase microextraction (SPME). GO-CFs were filled into a poly(ether ether ketone) (PEEK) tube to obtain a fibers-in-tube SPME device, which was connected with high performance liquid chromatography (HPLC) equipment to build online SPME-HPLC system. Compared with CFs, GO-CFs presented obviously better extraction performance, due to excellent adsorption property and large surface area of GO. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, the important extraction conditions were optimized, such as sample flow rate, extraction time, organic solvent content and desorption time. An online analysis method was established with wide linear range (0.01-50μgL -1 ) and low detection limits (0.001-0.004μgL -1 ). Good sensitivity resulted from high enrichment factors (1133-3840) of GO-CFs in-tube device towards PAHs. The analysis method was used to online determination of PAHs in wastewater samples. Some target analytes were detected and relative recoveries were in the range of 90.2-112%. It is obvious that the proposed GO-CFs in-tube device was an efficient extraction device, and EPD could be used to develop nanomaterials functionalized sorbents for sample preparation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Preparation, in vitro release, and pharmacokinetics in rabbits of lyophilized injection of sorafenib solid lipid nanoparticles

    PubMed Central

    Zhang, Hong; Zhang, Fu-Ming; Yan, Shi-Jun

    2012-01-01

    Sorafenib solid lipid nanoparticles (S-SLN) were prepared by emulsion evaporation–solidification at low temperature. Morphology was examined by transmission electron microscope. Particle size and zeta potential were determined by laser granularity equipment. Encapsulation efficiency (EE) was detected by Sephadex gel chromatography and high-performance liquid chromatography (HPLC). The in vitro release profile of S-SLN was studied with dialysis technology. The lyophilized injection of S-SLN was prepared by freeze drying and analyzed by differential scanning calorimetry. The plasma concentration of sorafenib in blood was determined by HPLC. The solid lipid nanoparticles assumed a spherical shape with an even distribution of diameter and particle size 108.23 ± 7.01 nm (n = 3). The polydispersity index, zeta potential, and EE were determined to be 0.25 ± 0.02, −16.37 ± 0.65 mV, and 93.49% ± 1.87%, respectively (n = 3). The in vitro release accorded with the Weibull distribution model. An equal volume of 15% (w/v) mannitol performed better as the protective agent for a lyophilized injection of S-SLN with a new material phase formation. The pharmacokinetic processes of sorafenib solution and lyophilized injection of S-SLN in vivo were in accordance with the two-compartment and one-compartment models, respectively. S-SLN nanoparticles are thus considered a promising drug-delivery system. PMID:22787390

  12. Validation of blood vitamin A concentrations in cattle: comparison of a new cow-side test (iCheck™ FLUORO) with high-performance liquid chromatography (HPLC).

    PubMed

    Raila, Jens; Kawashima, Chiho; Sauerwein, Helga; Hülsmann, Nadine; Knorr, Christoph; Myamoto, Akio; Schweigert, Florian J

    2017-05-10

    Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC). The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP). Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r 2  = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison. With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.

  13. Ion Chromatography-on-a-chip for Water Quality Analysis

    NASA Technical Reports Server (NTRS)

    Kidd, R. D.; Noell, A.; Kazarians, G.; Aubrey, A. D.; Scianmarello, N.; Tai, Y.-C.

    2015-01-01

    We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

  14. Trace analysis of pollutants in water using the photothermal interferometry as HPLC detector.

    PubMed

    Seidel, B S; Dübel, O; Faubel, W; Ache, H J

    1996-03-01

    A new procedure including high performance liquid chromatography in combination with photothermal interference spectroscopy as detection device (HPLC/PIS) has been proposed, optimized and its figures of merit for pesticide residue analysis are shown. The flowing sample under study is set in one arm of a Mach-Zehnder interferometer, and its refractive index is modulated by a periodically chopped continuous wave argon ion laser. As chopper, an acousto optical modulator has been introduced to switch the excitation laser beam between different lines (457 nm, 488 nm, 514 nm) simultaneously. Thus a multi component analysis can be realized either by using an HPLC-system in front of the PIS device or by a multi line Ar(+)-laser, directly. The limit of detection of the HPLC/PIS system reached 71 microg/l of the pesticide di-nitro-ortho-cresol (DNOC).

  15. Characterization of chemical constituents in Rhodiola Crenulate by high-performance liquid chromatography coupled with Fourier-transform ion cyclotron resonance mass spectrometer (HPLC-FT-ICR MS).

    PubMed

    Han, Fei; Li, Yanting; Mao, Xinjuan; Xu, Rui; Yin, Ran

    2016-05-01

    In this work, an approach using high-performance liquid chromatography coupled with diode-array detection and Fourier-transform ion cyclotron resonance mass spectrometer (HPLC-FT-ICR MS) for the identification and profiling of chemical constituents in Rhodiola crenulata was developed for the first time. The chromatographic separation was achieved on an Inertsil ODS-3 column (150 mm × 4.6 mm,3 µm) using a gradient elution program, and the detection was performed on a Bruker Solarix 7.0 T mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 48 chemical compounds, including 26 alcohols and their glycosides, 12 flavonoids and their glycosides, 5 flavanols and gallic acid derivatives, 4 organic acids and 1 cyanogenic glycoside were identified or tentatively characterized. The results indicated that the developed HPLC-FT-ICR MS method with ultra-high sensitivity and resolution is suitable for identifying and characterizing the chemical constituents in R. crenulata. And it provides a helpful chemical basis for further research on R. crenulata. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Simultaneous analysis of different classes of phytohormones in coconut (Cocos nucifera L.) water using high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry after solid-phase extraction.

    PubMed

    Ma, Zhen; Ge, Liya; Lee, Anna S Y; Yong, Jean Wan Hong; Tan, Swee Ngin; Ong, Eng Shi

    2008-03-10

    Coconut (Cocos nucifera L.) water, which contains many uncharacterized phytohormones is extensively used as a growth promoting supplement in plant tissue culture. In this paper, a high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of various classes phytohormones, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N(6)-benzyladenine (BA), alpha-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D) in young coconut water (CW). The analysis was carried out using a reverse-phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid, pH adjusted to 3.2 with triethylamine (TEA)) modified by methanol, and solute detection made at 265 nm wavelength. The method was validated for specificity, quantification, accuracy and precision. After preconcentration of putative endogenous phytohormones in CW using C(18) solid-phase extraction (SPE) cartridges, the HPLC method was able to screen for putative endogenous phytohormones present in CW. Finally, the identities of the putative phytohormones present in CW were further confirmed using independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) equipped with an electrospray ionization (ESI) interface.

  17. Multivariate optimization and validation of an analytical methodology by RP-HPLC for the determination of losartan potassium in capsules.

    PubMed

    Bonfilio, Rudy; Tarley, César Ricardo Teixeira; Pereira, Gislaine Ribeiro; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim

    2009-11-15

    This paper describes the optimization and validation of an analytical methodology for the determination of losartan potassium in capsules by HPLC using 2(5-1) fractional factorial and Doehlert designs. This multivariate approach allows a considerable improvement in chromatographic performance using fewer experiments, without additional cost for columns or other equipment. The HPLC method utilized potassium phosphate buffer (pH 6.2; 58 mmol L(-1))-acetonitrile (65:35, v/v) as the mobile phase, pumped at a flow rate of 1.0 mL min(-1). An octylsilane column (100 mm x 4.6mm i.d., 5 microm) maintained at 35 degrees C was used as the stationary phase. UV detection was performed at 254 nm. The method was validated according to the ICH guidelines, showing accuracy, precision (intra-day relative standard deviation (R.S.D.) and inter-day R.S.D values <2.0%), selectivity, robustness and linearity (r=0.9998) over a concentration range from 30 to 70 mg L(-1) of losartan potassium. The limits of detection and quantification were 0.114 and 0.420 mg L(-1), respectively. The validated method may be used to quantify losartan potassium in capsules and to determine the stability of this drug.

  18. [A new HPLC procedure for cyclamate in food with pre-chromatographic derivatization].

    PubMed

    Schwedt, G; Hauck, M

    1988-08-01

    A high-pressure liquid chromatography (HPLC) procedure for the detection of cyclamate in liquid and solid samples is presented, which depends on oxidation and the reaction of cyclohexylamine with o-phthaldialdehyde to form a condensation product. The results of the HPLC analysis, using an RP-C 18 separation system with UV detection at 242 nm are reported. Contents, from 2 to 400 mg/l, can be detected in less than 2 h (HPLC analysis within 20 min) with relative standard deviations of 4%. Only for cucumber infusions were incomplete recoveries of 68% obtained.

  19. Determination of sulfonamides and trimethoprim using high temperature HPLC with simultaneous temperature and solvent gradient.

    PubMed

    Giegold, Sascha; Teutenberg, Thorsten; Tuerk, Jochen; Kiffmeyer, Thekla; Wenclawiak, Bernd

    2008-10-01

    A fast HPLC method for the analysis of eight selected sulfonamides (SA) and trimethoprim has been developed with the use of high temperature HPLC. The separation could be achieved in less than 1.5 min on a 50 mm sub 2 microm column with simultaneous solvent and temperature gradient programming. Due to the lower viscosity of the mobile phase and the increased mass transfer at higher temperatures, the separation could be performed on a conventional HPLC system obtaining peak widths at half height between 0.6 and 1.3 s.

  20. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    NASA Astrophysics Data System (ADS)

    Pedreira, W. R.; Sarkis, J. E. S.; da Silva Queiroz, C. A.; Rodrigues, C.; Tomiyoshi, I. A.; Abrão, A.

    2003-02-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL-1. The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences.

  1. Spectroscopic characterization and quantitative determination of atorvastatin calcium impurities by novel HPLC method

    NASA Astrophysics Data System (ADS)

    Gupta, Lokesh Kumar

    2012-11-01

    Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.

  2. Separation of {sup 32}P-postlabeled DNA adducts of polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons by HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, L.C.; Gallagher, J.E.; Lewtas, J.

    The {sup 32}P-postlabeling assay, thin-layer chromatography, and reverse-phase high-pressure liquid chromatography (HPLC) were used to separate DNA adducts formed from 10 polycyclic aromatic hydrocarbons (PAHs) and 6 nitrated polycyclic aromatic hydrocarbons (NO{sub 2}-PAHs). The PAHs included benzo[j]fluoranthene, benzo[k]fluoranthene, indeno[1,2,3-cd]pyrene, benzo[a]pyrene, chrysene, 6-methylchrysene, 5-methylchrysene, and benz[a]anthracene. The NO{sub 2}-PAHs included 1-nitropyrene, 2-nitrofluoranthene, 3-nitrofluoranthene, 1,6-dinitropyrene, 1,3-dinitropyrene, and 1,8-dinitropyrene. Separation of seven of the major PAH-DNA adducts was achieved by an initial PAH HPLC gradient system. The major NO{sub 2}-PAH-DNA adducts were not all separated from each other using the initial PAH HPLC gradient but were clearly separated from the PAH-DNA adducts. Amore » second NO{sub 2}-PAH HPLC gradient system was developed to separate NO{sub 2}-PAH-DNA adducts following one-dimensional TLC and HPLC analysis. HPLC profiles of NO{sub 2}-PAH-DNA adducts were compared using both adduct enhancement versions of the {sup 32}P-postlabeling assay to evaluate the use of this technique on HPLC to screen for the presence of NO{sub 2}-PAH-DNA adducts. To demonstrate the application of these separation methods to a complex mixture of DNA adducts, the chromatographic mobilities of the {sup 32}P-postlabeled DNA adduct standards (PAHs and NO{sub 2}-PAHs) were compared with those produced by a complex mixture of polycyclic organic matter (POM) extracted from diesel emission particles. The diesel-derived adducts did not elute with the identical retention time of any of the PAH or NO{sub 2}-PAH standards used in this study. HPLC analyses of the NO{sub 2}-PAH-derived adducts (butanol extracted) revealed the presence of multiple DNA adducts.« less

  3. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Fought, E.R.

    1989-09-19

    A moving belt interface is described for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer. 8 figs.

  4. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Fought, Eric R.

    1989-01-01

    A moving belt interface for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer.

  5. Reversed Phase Column HPLC-ICP-MS Conditions for Arsenic Speciation Analysis of Rice Flour.

    PubMed

    Narukawa, Tomohiro; Matsumoto, Eri; Nishimura, Tsutomu; Hioki, Akiharu

    2015-01-01

    New measurement conditions for arsenic speciation analysis of rice flour were developed using HPLC-ICP-MS equipped with a reversed phase ODS column. Eight arsenic species, namely, arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), trimethylarsine oxide (TMAO), tetramethylarsonium (TeMA), arsenobetaine (AsB) and arsenocholine (AsC), were separated and determined under the proposed conditions. In particular, As(III) and MMAA and DMAA and AsB were completely separated using a newly proposed eluent containing ammonium dihydrogen phosphate. Importantly, the sensitivity changes, in particular those of As(V) and As(III) caused by coexisting elements and by complex matrix composition, which had been problematical in previously reported methods, were eliminated. The new eluent can be applied to C8, C18 and C30 ODS columns with the same effectiveness and with excellent repeatability. The proposed analytical method was successfully applied to extracts of rice flour certified reference materials.

  6. Isolation and purification of series bioactive components from Hypericum perforatum L. by counter-current chromatography.

    PubMed

    Cao, Xueli; Wang, Qiaoe; Li, Yan; Bai, Ge; Ren, Hong; Xu, Chunming; Ito, Yoichiro

    2011-03-01

    Counter-current chromatography (CCC) combined with pre-separation by ultrasonic solvent extraction was successively used for the separation of series bioactive compounds from the crude extract of Hypericum perforatum L. The petroleum ether extract was separated by the solvent system of n-heptane-methanol-acetonitrile (1.5:0.5:0.5, v/v) and n-heptane-methanol (1.5:1, v/v) in gradient elution, yielding a phloroglucinol compound, hyperforin with HPLC purity over 98%. The ethyl acetate extract was separated by using the solvent system composed of hexane-ethyl acetate-methanol-water (1:1:1:1 and 1:3:1:3, v/v) in gradient through both reverse phase and normal phase elution mode, yielding a naphthodianthrone compound, hypericin with HPLC purity about 95%. The n-butanol extract was separated with the solvent system composed of n-butanol-ethyl acetate-water (1:4:5 and 1.5:3.5:5, v/v) in elution and back-extrusion mode, yielding two of flavones, rutin and hyperoside, with HPLC purity over 95%. HPLC-MS, reference sample and UV spectrum were selectively used in separation to search for target compounds from HPLC-DAD profiles of different sub-extracts. The structures of isolated compounds were further identified by ESI-MS, ¹HNMR and ¹³CNMR. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Isolation and purification of series bioactive components from Hypericum Perforatum L. by high-speed counter-current chromatography

    PubMed Central

    Cao, Xueli; Wang, Qiaoe; Li, Yan; Bai, Ge; Ren, Hong; Ito, Yiochiro

    2011-01-01

    High-speed counter-current chromatography (HSCCC) combined with pre-separation by ultrasonic solvent extraction was successively used for the separation of series bioactive compounds from the crude extract of Hypericum perforatum L. The petroleum ether extract was separated by the solvent system of n-heptane-methanol-acetonitrile (1.5:0.5:0.5, v/v) and n-heptane-methanol (1.5:1, v/v) in gradient elution, yielding a phloroglucinol compound, hyperforin with HPLC purity over 98%. The ethyl acetate extract was separated by using the solvent system composed of hexane-ethyl acetate-methanol-water (1:1:1:1 and 1:3:1:3, v/v) in gradient through both reverse phase and normal phase elution mode, yielding a naphthodianthrone compound, hypericin with HPLC purity about 95%. The n-butanol extract was separated with the solvent system composed of n-butanol-ethyl acetate–water (1:4:5 and 1.5:3.5:5, v/v) in elution and back-extrusion mode, yielding two of flavones, rutin and hyperoside, with HPLC purity over 95%. HPLC-MS, reference sample and UV spectrum were selectively used in separation to search for target compounds from HPLC-DAD profiles of different sub-extracts. The structures of isolated compounds were further identified by ESI-MS, 1HNMR and 13CNMR. PMID:21306961

  8. Automated measurement of carbohydrate-deficient transferrin using the Bio-Rad %CDT by the HPLC test on a Variant HPLC system: evaluation and comparison with other routine procedures.

    PubMed

    Schellenberg, François; Mennetrey, Louise; Girre, Catherine; Nalpas, Bertrand; Pagès, Jean Christophe

    2008-01-01

    In this study, we evaluated the new %CDT by the HPLC method (Bio-Rad, Germany) on a Varianttrade mark HPLC system (Bio-Rad), checked the correlation with well-known methods and calculated the diagnostic value of the test. Intra-run and day-to-day precision values were calculated for samples with extreme serum transferrin concentrations, high trisialotransferrin and interfering conditions (haemolysed, lactescent and icteric samples). The method was compared with two routine procedures, the %CDT TIA (Bio-Rad, Hercules, CA, USA) and the Capillarystrade mark CDT (Sebia, France). A total of 350 clinical sera samples were used for a case-control study. Precision values were better in high CDT and medium CDT pools than in low CDT pools. The serum transferrin concentration had no effect on CDT measurement, except in samples with serum transferrin <1 g/L. Haemolysis was the only interfering situation. The method showed high correlation (r(2) > 0.95) with the two other methods (%CDT TIA and CZE %CDT). The global predictive value of the test was >0.90 at 1.9% cut-off. These results demonstrate that the %CDT by the HPLC test is suitable for CDT routine measurement; the results from the high-throughput Varianttrade mark system are well correlated with other methods and are of high diagnostic value.

  9. High-throughput metabolic stability studies in drug discovery by orthogonal acceleration time-of-flight (OATOF) with analogue-to-digital signal capture (ADC).

    PubMed

    Temesi, David G; Martin, Scott; Smith, Robin; Jones, Christopher; Middleton, Brian

    2010-06-30

    Screening assays capable of performing quantitative analysis on hundreds of compounds per week are used to measure metabolic stability during early drug discovery. Modern orthogonal acceleration time-of-flight (OATOF) mass spectrometers equipped with analogue-to-digital signal capture (ADC) now offer performance levels suitable for many applications normally supported by triple quadruple instruments operated in multiple reaction monitoring (MRM) mode. Herein the merits of MRM and OATOF with ADC detection are compared for more than 1000 compounds screened in rat and/or cryopreserved human hepatocytes over a period of 3 months. Statistical comparison of a structurally diverse subset indicated good agreement for the two detection methods. The overall success rate was higher using OATOF detection and data acquisition time was reduced by around 20%. Targeted metabolites of diazepam were detected in samples from a CLint determination performed at 1 microM. Data acquisition by positive and negative ion mode switching can be achieved on high-performance liquid chromatography (HPLC) peak widths as narrow as 0.2 min (at base), thus enabling a more comprehensive first pass analysis with fast HPLC gradients. Unfortunately, most existing OATOF instruments lack the software tools necessary to rapidly convert the huge amounts of raw data into quantified results. Software with functionality similar to open access triple quadrupole systems is needed for OATOF to truly compete in a high-throughput screening environment. Copyright 2010 John Wiley & Sons, Ltd.

  10. Simultaneous determination of secondary metabolites from Vinca rosea plant extractives by reverse phase high performance liquid chromatography

    PubMed Central

    Siddiqui, Mohammad Jamshed Ahmad; Ismail, Zhari; Saidan, Noor Hafizoh

    2011-01-01

    Background: Vinca rosea (Apocynaceae) is one of the most important and high value medicinal plants known for its anticancer alkaloids. It is the iota of the isolated secondary metabolites used in chemotherapy to treat diverse cancers. Several high performance liquid chromatography (HPLC) methods have been developed to quantify the active alkaloids in the plant. However, this method may serve the purpose in quantification of V. rosea plant extracts in totality. Objective: To develop and validate the reverse phase (RP)-HPLC method for simultaneous determination of secondary metabolites, namely alkaloids from V. rosea plant extracts. Materials and Methods: The quantitative determination was conducted by RP-HPLC equipped with ultraviolet detector. Optimal separation was achieved by isocratic elution with mobile phase consisting of methanol:acetonitrile:ammonium acetate buffer (25 mM) with 0.1% triethylamine (15:45:40 v/v) on a column (Zorbax Eclipse plus C18, 250 mm % 4.6 mm; 5 μm). The standard markers (vindoline, vincristine, catharanthine, and vinblastine) were identified by retention time and co-injected with reference standard and quantified by external standard method at 297 nm. Results: The precision of the method was confirmed by the relative standard deviation (R.S.D.), which was lower than 2.68%. The recoveries were in the range of 98.09%-108%. The limits of detection (LOD) for each marker alkaloids were lower than 0.20 μg. Different parts of the V. rosea extracts shows different concentrations of markers, flower samples were high in vinblastine content, while methanol extract from the leaves contains all the four alkaloids in good yield, and there is no significant presence of markers in water extracts. Conclusion: HPLC method established is appropriate for the standardization and quality assurance of V. rosea plant extracts. PMID:21716929

  11. Quantitative and Qualitative Analysis of Biomarkers in Fusarium verticillioides

    USDA-ARS?s Scientific Manuscript database

    In this study, a combination HPLC-DART-TOF-MS system was utilized to identify and quantitatively analyze carbohydrates in wild type and mutant strains of Fusarium verticillioides. Carbohydrate fractions were isolated from F. verticillioides cellular extracts by HPLC using a cation-exchange size-excl...

  12. Automated in-line gel filtration for native state mass spectrometry.

    PubMed

    Waitt, Greg M; Xu, Robert; Wisely, G Bruce; Williams, Jon D

    2008-02-01

    Characterization of protein-ligand complexes by nondenaturing mass spectrometry provides direct evidence of drug-like molecules binding with potential therapeutic targets. Typically, protein-ligand complexes to be analyzed contain buffer salts, detergents, and other additives to enhance protein solubility, all of which make the sample unable to be analyzed directly by electrospray ionization mass spectrometry. This work describes an in-line gel-filtration method that has been automated and optimized. Automation was achieved using commercial HPLC equipment. Gel column parameters that were optimized include: column dimensions, flow rate, packing material type, particle size, and molecular weight cut-off. Under optimal conditions, desalted protein ions are detected 4 min after injection and the analysis is completed in 20 min. The gel column retains good performance even after >200 injections. A demonstration for using the in-line gel-filtration system is shown for monitoring the exchange of fatty acids from the pocket of a nuclear hormone receptor, peroxisome proliferator activator-delta (PPARdelta) with a tool compound. Additional utilities of in-line gel-filtration mass spectrometry system will also be discussed.

  13. A nitromethane-based HPLC system alternative to acetonitrile for carotenoid analysis of fruit and vegetables.

    PubMed

    Sandmann, Gerhard

    2010-01-01

    Acetonitrile-based HPLC systems are the most commonly used for carotenoid analysis from different plant tissues. Because of the acetonitrile shortage, an HPLC system for the separation of carotenoids on C(18) reversed-phase columns was developed in which an acetonitrile-alcohol-based mobile phase was replaced by nitromethane. This solvent comes closest to acetonitrile with respect to its elutrophic property. Our criterion was to obtain similar separation and retention times for a range of differently structured carotenoids. This was achieved by further increase in the lipophilicity with ethylacetate. For all the carotenoids which we tested, we found co-elution only of β-cryptoxanthin and lycopene. By addition of 1% of water, separation of this pair of carotenoids was also achieved. The final recommended mobile phase consisted of nitromethane : 2-propanol : ethyl acetate : water (79 : 10 : 10 : 1, by volume). On Nucleosil C(18) columns and related ones like Hypersil C(18), we obtained separation of carotenes, hydroxyl, epoxy and keto derivatives, which resembles the excellent separation properties of acetonitrile-based mobile phases on C(18) reversed phase columns. We successfully applied the newly developed HPLC system to the separation of carotenoids from different vegetables and fruit. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Determination of the pseudoephedrine content in pharmaceutical formulations and in biological fluids using a microbore HPLC system interfaced to a microfluidic chemiluminescence detector.

    PubMed

    Kadavilpparampu, Afsal Mohammed; Al-Lawati, Haider A J; Suliman, FakhrEldin O; Al Kindy, Salma M Z

    2015-12-01

    A novel automated precolumn derivatization followed by separation using liquid chromatography for the determination of pseudoephedrine (PSE) by a microfluidic chemiluminescence detector has been developed. An on-line derivatization procedure was utilized by converting PSE into a highly light emitting species in a Ru(bipy)3(2+)-peroxydisulphate chemiluminescence (CL) system by derivatizing it with a 1.0 M formaldehyde solution. The derivatized analyte was directly injected into a microbore high-performance liquid chromatography (HPLC) system coupled to an on-chip chemiluminescence detector. The newly developed highly selective, sensitive and fast HPLC-CL method was validated and successfully applied for the analysis of PSE in pharmaceutical formulations and a human urine sample. The selectivity of the method is not only due to the HPLC separation but is also due to the highly selective detection principle of the Ru(bipy)3(2+)-peroxydisulphate CL system used. There was no interference observed from the common preservatives and excipients used in pharmaceutical preparations, which did not show any significant CL signal. The retention time of PSE was less than 3 min, and the detection limits and quantification limits were found to be 5.7 and 26.0 µg L(-1), respectively. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Monitoring gradient profile on-line in micro- and nano-high performance liquid chromatography using conductivity detection.

    PubMed

    Zhang, Min; Chen, Apeng; Lu, Joann J; Cao, Chengxi; Liu, Shaorong

    2016-08-19

    In micro- or nano-flow high performance liquid chromatography (HPLC), flow-splitters and gradient elutions are commonly used for reverse phase HPLC separations. When a flow splitter was used at a high split-ratio (e.g., 1000:1 or higher), the actual gradient may deviate away from the programmed gradient. Sometimes, mobile phase concentrations can deviate by as much as 5%. In this work, we noticed that the conductivity (σ) of a gradient decreased with the increasing organic-solvent fraction (φ). Based on the relationship between σ and φ, a method was developed for monitoring gradient profile on-line to record any deviations in these HPLC systems. The conductivity could be measured by a traditional conductivity detector or a capacitively coupled contactless conductivity detector (C(4)D). The method was applied for assessing the performance of an electroosmotic pump (EOP) based nano-HPLC. We also observed that σ value of the gradient changed with system pressure; a=0.0175ΔP (R(2)=0.964), where a is the percentage of the conductivity increase and ΔP is the system pressure in bar. This effect was also investigated. Copyright © 2016. Published by Elsevier B.V.

  16. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    PubMed

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. A FIVE YEAR RECORD OF PHYTOPLANKTON PIGMENT PATTERNS IN ESCAMBIA/PENSACOLA BAY, FL

    EPA Science Inventory

    Phytoplankton pigments were monitored quarterly at over 50 stations in Escambia/Pensacola Bay System (Pensacola, FL) from spring of 1996 to fall 2000. HPLC accessory pigments were used to analyze the phytoplankton community structure. HPLC data suggest a dominance of blue-green a...

  18. Composition and stability of phytochemicals in five varieties of black soybeans (glycine max)

    USDA-ARS?s Scientific Manuscript database

    Phytochemical compositions of five varieties of black soybeans (Glycine max) and their stabilities at room temperature, 4 deg.C and -80 deg.C over 14 months were determined by HPLC systems with electrochemical (HPLC-ECD) and UV detectors. Polyphenol profiling was carried out by liquid chromatography...

  19. 40 CFR 86.1309-90 - Exhaust gas sampling system; Otto-cycle and non-petroleum-fueled engines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., shall exceed either 2.5 mg/l or a concentration equal to 25 times the limit of detection for the HPLC..., shall exceed either 2.5 mg/l or a concentration equal to 25 times the limit of detection for the HPLC...

  20. 40 CFR 86.1309-90 - Exhaust gas sampling system; Otto-cycle and non-petroleum-fueled engines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., shall exceed either 2.5 mg/l or a concentration equal to 25 times the limit of detection for the HPLC..., shall exceed either 2.5 mg/l or a concentration equal to 25 times the limit of detection for the HPLC...

  1. [Study of the content of flavonoids of different parts in Saussures involucrata and their HPLC fingerprint chromatogram].

    PubMed

    Huang, Yi; Zhou, Qian; Yan, Ming; Xu, Fang; Kang, Airong; Yan, Huan; Hong, Lijun; Wang, Xintang; Zhong, Jie

    2005-11-01

    To determine the content of flavonoids and rutin in the different parts of Saussurea involucrata, and to establish their HPLC fingerprint chromatogram for the further development and utilization of the leaf. The content of flavonoids was determined with UV. The similarity evaluation system for chromatographic fingerprint of TCM was used to calculate similar degree of the HPLC chromatogram of different parts. The content of flavonoids and rutin is relatively high in the leaf. The similarity between leaf and the whole grass is 0. 812.

  2. Comparison of adsorption coefficient (K[sub oc]) for soils and HPLC retention factors of aromatic hydrocarbons using a chemically immobilized humic acid column in RP-HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szabo, G.; Bulman, R.A.

    The determination of soil adsorption coefficients (K[sub oc]) via HPLC capacity factors (k[prime]) has been studied, including the effect of column type and mobile phase composition on the correlation between log K[sub oc] and log k[prime]. K[sub oc] values obtained by procedures other than HPLC correlate well with HPLC capacity factors determined on a chemically immobilized humic acid stationary phase, and it is suggested that this phase is a better model for the sorption onto soil or sediment than the octadecyl-, phenyl- and ethylsilica phases. By using log k[prime][sub w] a theoretical capacity factor has been obtained by extrapolation ofmore » the retention data in a binary solvent system to pure aqueous eluent. There is a better correlation between log K[sub oc] and log k[prime][sub w] than the correlation between log K[sub oc] and log k[prime].« less

  3. Using HPLC-Mass Spectrometry to Teach Proteomics Concepts with Problem-Based Techniques

    ERIC Educational Resources Information Center

    Short, Michael; Short, Anne; Vankempen, Rachel; Seymour, Michael; Burnatowska-Hledin, Maria

    2010-01-01

    Practical instruction of proteomics concepts was provided using high-performance liquid chromatography coupled with a mass selective detection system (HPLC-MS) for the analysis of simulated protein digests. The samples were prepared from selected dipeptides in order to facilitate the mass spectral identification. As part of the prelaboratory…

  4. Comparative evaluation of ICP sample introduction systems to be used in the metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS.

    PubMed

    Klencsár, Balázs; Sánchez, Carlos; Balcaen, Lieve; Todolí, José; Lynen, Frederic; Vanhaecke, Frank

    2018-05-10

    A systematic evaluation of four different ICP sample introduction systems to be used in the context of metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS was carried out using diclofenac and its major metabolite, 4'-hydroxy-diclofenac, as model compounds. The strict requirements for GMP validation of chromatographic methods in the pharmaceutical industry were adhered to in this context. The final aim of this investigation is an extension of the applicability and validatability of HPLC-ICP-MS in the field of pharmaceutical R&D. Five different gradient programmes were tested while the baseline peak width (w b ), peak capacity (P), USP tailing factor (A s ) and USP signal-to-noise ratio (USP S/N) were determined as major indicators of the chromatographic performance and the values obtained were compared to the corresponding FDA recommendations (if applicable). Four different ICP-MS sample introductions systems were investigated involving two units typically working at higher flow rates (∼1.0 mL min -1 ) and another two systems working at lower flow rates (∼0.1 mL min -1 ). Optimal conditions with potential for applicability under GMP conditions were found at a mobile phase flow rate of 1.0 mL min -1 by using a pneumatic micro-flow LC nebulizer mounted onto a Peltier-cooled cyclonic spray chamber cooled to -1 °C for sample introduction. Under these conditions, HPLC-ICP-MS provided a chromatographic performance similar to that of HPLC with UV detection. The peak shape (USP tailing factor = 1.1-1.4) was significantly improved compared to that obtained with the Peltier-cooled Scott-type spray chamber. Two alternative sample introduction systems - a POINT ® and a High-Temperature Torch-Integrated Sample Introduction System (hTISIS) - were also tested at a flow rate of 0.1 mL min -1 using a chromatographic column with 1.0 mm ID. Although these systems allowed the peak shape to be improved compared to that obtained with the traditional Scott-type spray chamber, the limits of detection and of quantification achievable were strongly compromised due to the significantly lower sensitivity observed for Cl. In addition to a comparison of the aforementioned sample introduction systems, also the effect of spray chamber temperature was evaluated and it was demonstrated that proper temperature control plays an essential role in the optimization of HPLC-ICP-MS methods. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Quantitation of polymethoxylated flavones in orange juice by high-performance liquid chromatography.

    PubMed

    Rouseff, R L; Ting, S V

    1979-08-01

    A quantitative high-performance liquid chromatographic (HPLC) procedure for the determination of the five major polymethoxylated flavones (PMFs) in orange juice has been developed. It employs a unique ternary solvent system with coupled UV-fluorescence detection. The dual detectors were employed to determine the presence of interfering substances and served as a cross check on quantitation. Stop flow UV and fluorescence scanning was used to identify peaks and determine the presence of impurities. Although all five citrus PMFs fluoresce, some HPLC fluorescence peaks were too small to be of much practical use. All five citrus PMFs could be quantitated satisfactorily with the fixed wavelength UV (313 nm) detector. The HPLC procedure has been used to evaluate each step in the preparation. The optimum extracting solvent was selected and one time consuming step was eliminated, as it was found to be unnecessary. HPLC values for nobiletin and sinensetin are in good agreement with the thin-layer chromatographic (TLC) values in the literature. HPLC values for the other three flavones were considerably lower than those reported in the literature. The HPLC procedure is considerably faster than the TLC procedure with equal or superior precision and accuracy.

  6. Application of ion-trap mass spectrometry for identification and structural determination of an unknown impurity in simvastatin.

    PubMed

    Reddy, G V Ram; Kumar, A Praveen; Reddy, B Venkateswara; Sreeramulu, J

    2009-10-01

    Anhydro-simvastatin and simvastatin dimer are the two main impurities in the fermentation broth as well as in the final product of simvastatin, which is a hypolipidemic drug. An unknown impurity with m/z 451 for [(M + H)(+)] was detected in the analysis of final simvastatin drug sample. By using reverse phase high performance liquid chromatography (HPLC)-mass spectrometry (MS) and MS/MS spectra, the unknown impurity was detected and identified. Separation was achieved on ACE-5 C18 (150 x 4.6 mm, 3 microm column) at the flow rate of 1.2 ml min(-1) applying gradient elution of mobile phase A consisting of Milli-Q water of pH 3.0 with formic acid and B consisting of acetonitrile. MS/MS spectrum of the unknown impurity was obtained using HPLC-MS equipped with positive electrosoray ionization (ESI). The unknown impurity is named as 7-[7-(2,2-dimethyl-butyryloxy)-2,6-dimethyl-1,2,6,7,8,8a-hexahydro-naphthalen-1 -yl]-3-hydroxy-5-hydroxymethyl-heptanoic acid.

  7. Photochemical transformation of azoxystrobin in aqueous solutions.

    PubMed

    Boudina, A; Emmelin, C; Baaliouamer, A; Païssé, O; Chovelon, J M

    2007-07-01

    The photochemical behaviour of azoxystrobin fungicide (AZX) in water was studied under laboratory conditions. Photodegradation was initiated using a solar simulator (xenon arc lamp) or a jacketed Pyrex reaction cell equipped with a 125 W, high-pressure mercury lamp. HPLC/MS analysis (APCI and ESI in positive and negative modes) was used to identify AZX photoproducts. The calculated polychromatic quantum efficiencies (phi) of AZX at pH 4.5, 7 and 9 were 5.42 x 10(-3), 3.47 x 10(-3) and 3.06 x 10(-3) (degraded molecules per absorbed photon), respectively. The relatively narrow range of values indicates the stability of AZX with respect to photodegradation in the studied pH range. Results from the HPLC/MS analysis suggest that the phototransformation of AZX proceeds via multiple, parallel reaction pathways including: (1) photo-isomerization (E-->Z), (2) photo-hydrolysis of the methyl ester and of the nitrile group, (3) cleavage of the acrylate double bond, (4) photohydrolytic ether cleavage between the aromatic ring giving phenol, and (5) oxidative cleavage of the acrylate double bond.

  8. Conventional sample enrichment strategies combined with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance analysis allows analyte identification from a single minuscule Corydalis solida plant tuber.

    PubMed

    Sturm, Sonja; Seger, Christoph; Godejohann, Markus; Spraul, Manfred; Stuppner, Hermann

    2007-09-07

    Identification of putative biomarker molecules within the genus Corydalis (Papaveraceae) was pursued by combining conventional off-line sample enrichment with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance (HPLC-SPE-NMR) based structure elucidation. Off-line reversed phase solid phase extraction (SPE) was used to enrich the desired analytes from a methanolic extract (93 mg dry weight) of a miniscule single tuber (233 mg dry weight) of C. solida. An aliquot of the SPE fraction (2.1 mg) was subjected to separation in the HPLC-SPE-NMR hyphenation. Chromatographic peaks bearing the metabolites under investigation were trapped in the SPE device in a single experiment and transferred to a 600 MHz NMR spectrometer equipped with a 30 microl cryofit insert fed into a 3 mm cryoprobe. Recorded homo- and heteronuclear 1D and 2D NMR data allowed the identification of the three analytes under investigation as protopine, allocryptopine, and N-methyl-laudanidinium acetate. The latter is a rare alkaloid, which has been isolated only once before.

  9. A pretreatment method for HPLC analysis of cypermethrin in microbial degradation systems.

    PubMed

    Liu, Shuliang; Yao, Kai; Jia, Dongying; Zhao, Nan; Lai, Wen; Yuan, Huaiyu

    2012-07-01

    In this paper, a pretreatment method for high-performance liquid chromatography (HPLC) determination of cypermethrin (CY) in microbial degradation systems was systemically studied, primarily to solve the problem of inaccurate determination of CY concentration caused by its uneven distribution in the systems. A suitable pretreatment method was established, including sampling, extraction and dehydration of CY. Partial sampling could be taken for bacterial and yeast systems in which CY was uniformly dispersed by an emulsifying agent, while total sampling was only suitable for mold systems with or without an emulsifying agent. CY could be fully extracted from the samples in which microbial cells were disrupted by ultrasonic treatment with acetonitrile under ultrasonic condition. The extract could be effectively dehydrated and purified by passing it through an anhydrous Na(2)SO(4) column followed by an elution with acetonitrile. The determination of CY in the pretreated sample by HPLC showed a high precision [relative standard deviation (RSD) = 1.14%, n = 5] and a good stability over a period of five days (RSD = 1.57%, n = 5). The recoveries of CY in microbial degradation systems at three different spiked levels ranged from 95.68 to 108.09% (RSD = 0.50-5.87%, n = 5).

  10. Identification of geometrical isomers and comparison of different isomeric samples of astaxanthin.

    PubMed

    Qiu, Dan; Wu, Yue-Chan; Zhu, Wen-Li; Yin, Hong; Yi, Long-Tao

    2012-09-01

    A high-performance liquid chromatographic (HPLC) analysis system for isomeric astaxanthin was developed. The separation system consisted of a C(30) column and an elution system of methanol/MTBE/water/dichloromethane (77:13:8:2, v/v/v/v). Using the combination of HPLC diode array detector and HPLC atmospheric pressure chemical ionization mass spectrometry, 11 geometrical isomers and 4 epoxides of astaxanthin were successfully identified. Referred to crystal, only isomerization with different degrees was found for solvent dissolving and iodine catalysis, while melting of astaxanthin caused isomerization, slight oxidation, and more noticeable polymerization confirmed by gel permeation chromatography. Chemical changes in isomeric samples all caused a decrease in UV content. The vibrational spectra (infrared and Raman) showed that epoxide was the only new functional group generated for melting. Changes of several key bands and formations of new bands were found in iodine catalysis and melting samples because of isomerization. Practical Application:  Eleven geometrical isomers and 4 epoxides, which were normally generated for solvent dissolving, iodine catalysis, and melting of astaxanthin, have been identified by C(30) -HPLC-MS technology. Furthermore, different samples were measured by gel permeation chromatography, UV, infrared, and Raman, based on the analysis of messages, the effect of each processing was well understood. © 2012 Institute of Food Technologists®

  11. On-line hyphenation of centrifugal partition chromatography and high pressure liquid chromatography for the fractionation of flavonoids from Hippophaë rhamnoides L. berries.

    PubMed

    Michel, Thomas; Destandau, Emilie; Elfakir, Claire

    2011-09-09

    Centrifugal Partition Chromatography (CPC), a liquid-liquid preparative chromatography using two immiscible solvent systems, benefits from numerous advantages for the separation or purification of synthetic or natural products. This study presents the on-line hyphenation of CPC-Evaporative Light Scattering Detector (CPC-ELSD) with High Performance Liquid Chromatography-UV (HPLC-UV) for the fractionation of flavonols from a solvent-free microwave extract of sea buckthorn (Hippophaë rhamnoides L., Elaeagnaceae) berries. An Arizona G system was used for the fractionation of flavonoids by CPC and a fused core Halo C18 column allowed the on-line analyses of collected fractions by HPLC. The on-line CPC/HPLC procedure allowed the simultaneous fractionation step at preparative scale combined with the HPLC analyses which provide direct fingerprint of collected fractions. Thus the crude extract was simplified and immediate information on the composition of fractions could be obtained. Furthermore, this methodology reduced the time of post-fractionation steps and facilitated identification of main molecules by Mass Spectrometry (MS). Rutin, isorhamnetin-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin-3-O-glucoside, isorhamnetin-rhamnoside, quercetin and isorhamnetin were identified. CPC-ELSD/HPLC-UV could be considered as a high-throughput technique for the guided fractionation of bioactive natural products from complex crude extracts. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. I. A thermodynamic perspective.

    PubMed

    Åsberg, Dennis; Leśko, Marek; Samuelsson, Jörgen; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2014-10-03

    This is the first investigation in a series that aims to enhance the scientific knowledge needed for reliable analytical method transfer between HPLC and UHPLC using the quality by design (QbD) framework. Here, we investigated the differences and similarities from a thermodynamic point of view between RP-LC separations conducted with 3.5μm (HPLC) and 1.7μm (UHPLC) C18 particles. Three different model solutes and one pharmaceutical compound were used: the uncharged cycloheptanone, the cationic benzyltriethylammonium chloride, the anionic sodium 2-naphatlene sulfonate and the pharmaceutical compound omeprazole, which was anionic at the studied pH. Adsorption data were determined for the four solutes at varying fractions of organic modifier and in gradient elution in both the HPLC and UHPLC system, respectively. From the adsorption data, the adsorption energy distribution of each compound was calculated and the adsorption isotherm model was estimated. We found that the adsorption energy distribution was similar, with only minor differences in degree of homogeneity, for HPLC and UHPLC stationary phases. The adsorption isotherm model did not change between HPLC and UHPLC, but the parameter values changed considerably especially for the ionic compounds. The dependence of the organic modifier followed the same trend in HPLC as in UHPLC. These results indicates that the adsorption mechanism of a solute is the same on HPLC and UHPLC stationary phases which simplifies design of a single analytical method applicable to both HPLC and UHPLC conditions within the QbD framework. Copyright © 2014. Published by Elsevier B.V.

  13. Analytical strategy for the determination of various arsenic species in landfill leachate containing high concentrations of chlorine and organic carbon by HPLC-ICPMS

    NASA Astrophysics Data System (ADS)

    Bae, J.; An, J.; Kim, J.; Jung, H.; Kim, K.; Yoon, C.; Yoon, H.

    2012-12-01

    As a variety of wastes containing arsenic are disposed of in landfills, such facilities can play a prominent role in disseminating arsenic sources to the environment. Since it is widely recognized that arsenic toxicity is highly dependent on its species, accurate determination of various arsenic species should be considered as one of the essential goals to properly account for the potential health risk of arsenic in human and the environment. The inductively coupled plasma mass spectrometry linked to high performance liquid chromatography (HPLC-ICPMS) is acknowledged as one of the most important tools for the trace analysis of metallic speciation because of its superior separation capability and detectability. However, the complexity of matrices can cause severe interferences in the analysis results, which is the problem often encountered with HPLC-ICPMS system. High concentration of organic carbon in a sample solution causes carbon build-up on the skimmer and sampling cone, which reduces analytical sensitivity and requires a high maintenance level for its cleaning. In addition, argon from the plasma and chlorine from the sample matrix may combine to form 40Ar35Cl, which has the same nominal mass to charge (m/z) ratio as arsenic. In this respect, analytical strategy for the determination of various arsenic species (e.g., inorganic arsenite and arsenate, monomethylarsonic acid, dimethylarsinic acid, dimethyldithioarsinic acid, and arsenobetaine) in landfill leachate containing high concentrations of chlorine and organic carbon was developed in the present study. Solid phase extraction disk (i.e., C18 disk), which does not significantly adsorb any target arsenic species, was used to remove organic carbon in sample solutions. In addition, helium (He) gas was injected into the collision reaction cell equipped in ICPMS to collapse 40Ar35Cl into individual 40Ar and 35Cl. Although He gas also decreased arsenic intensity by blocking 75As, its signal to noise ratio significantly increased after injecting He gas. We demonstrated that the analytical strategy was achieved improved sensitivity for the determination of various arsenic species in the landfill leachate as one of the complex matrices.

  14. DETERMINATION OF VENLAFAXINE, VILAZODONE AND THEIR MAIN ACTIVE METABOLITES IN HUMAN SERUM BY HPLC-DAD AND HPLC-MS.

    PubMed

    Petruczynik, Anna; Wroblewski, Karol; Szultka-Mlynska, Malgorzata; Buszewsk, Boguslaw; Karakula-Juchnowicz, Hanna; Gajewski, Jacek; Morylowska-Topolska, Justyna; Waksmundzka-Hajnosi, Monika

    2017-05-01

    A high performance liquid chromatography (HPLC) method for simultaneous analysis of venlafaxine and its major metabolite 0-desmethylvenlafaxine and vilazodone and its methabolite M10 have been devel- oped and validated. Chromatography was performed on the Phenyl-Hexyl column with mobile phase containing methanol, acetate buffer at pH 3.5 and diethylamine. The application of stationary phase with 7r-7c moieties and mobile phase containing diethylamine as silanol blocker lets to obtain double protection against silanols and thus very high theoretical plate numbers were obtained. The good separation selectivity, good peaks' symmetry and very high systems efficiency for all investigated compounds were obtained in applied chromatographic system. The method is very efficient and suitable for the analysis of investigated drugs and their metabolites in human serum for patients' pharmacotherapy control.

  15. High-speed counter-current chromatography coupled online to high performance liquid chromatography-diode array detector-mass spectrometry for purification, analysis and identification of target compounds from natural products.

    PubMed

    Liang, Xuejuan; Zhang, Yuping; Chen, Wei; Cai, Ping; Zhang, Shuihan; Chen, Xiaoqin; Shi, Shuyun

    2015-03-13

    A challenge in coupling high-speed counter-current chromatography (HSCCC) online with high performance liquid chromatography (HPLC) for purity analysis was their time incompatibility. Consequently, HSCCC-HPLC was conducted by either controlling HPLC analysis time and HSCCC flow rate or using stop-and-go scheme. For natural products containing compounds with a wide range of polarities, the former would optimize experimental conditions, while the latter required more time. Here, a novel HSCCC-HPLC-diode array detector-mass spectrometry (HSCCC-HPLC-DAD-MS) was developed for undisrupted purification, analysis and identification of multi-compounds from natural products. Two six-port injection valves and a six-port switching valve were used as interface for collecting key HSCCC effluents alternatively for HPLC-DAD-MS analysis and identification. The ethyl acetate extract of Malus doumeri was performed on the hyphenated system to verify its efficacy. Five main flavonoids, 3-hydroxyphloridzin (1), phloridzin (2), 4',6'-dihydroxyhydrochalcone-2'-O-β-D-glucopyranoside (3, first found in M. doumeri), phloretin (4), and chrysin (5), were purified with purities over 99% by extrusion elution and/or stepwise elution mode in two-step HSCCC, and 25mM ammonium acetate solution was selected instead of water to depress emulsification in the first HSCCC. The online system shortened manipulation time largely compared with off-line analysis procedure and stop-and-go scheme. The results indicated that the present method could serve as a simple, rapid and effective way to achieve target compounds with high purity from natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Tantala-based sol-gel coating for capillary microextraction on-line coupled to high-performance liquid chromatography.

    PubMed

    Tran, MinhPhuong; Turner, Erica B; Segro, Scott S; Fang, Li; Seyyal, Emre; Malik, Abdul

    2017-11-03

    A sol-gel organic-inorganic hybrid sorbent, consisting of chemically integrated tantalum (V) ethoxide (TaEO) and polypropylene glycol methacrylate (PPGM), was developed for capillary microextraction (CME). The sol-gel sorbent was synthesized within a fused silica capillary through hydrolytic polycondensation of TaEO and chemical incorporation of PPGM into the evolving sol-gel tantala network. A part of the organic-inorganic hybrid sol-gel network evolving in the vicinity of the capillary walls had favorable conditions to get chemically bonded to the silanol groups on the capillary surface forming a surface-bonded coating. The newly developed sol-gel sorbent was employed to isolate and enrich a variety of analytes from aqueous samples for on-line analysis by high-performance liquid chromatography (HPLC) equipped with a UV detector. CME was performed on aqueous samples containing trace concentrations of analytes representing polycyclic aromatic hydrocarbons, ketones, alcohols, amines, nucleosides, and nucleotides. This sol-gel hybrid coating provided efficient extraction with CME-HPLC detection limits ranging from 4.41pM to 28.19 pM. Due to direct chemical bonding between the sol-gel sorbent coating and the fused silica capillary inner surface, this sol-gel sorbent exhibited enhanced solvent stability. The sol-gel tantala-based sorbent also exhibited excellent pH stability over a wide pH range (pH 0-pH 14). Furthermore, it displayed great performance reproducibility in CME-HPLC providing run-to-run HPLC peak area relative standard deviation (RSD) values between 0.23% and 3.83%. The capillary-to-capillary RSD (n=3), characterizing capillary preparation method reproducibility, ranged from 0.24% to 4.11%. The results show great performance consistency and application potential for the sol-gel tantala-PPGM sorbent in various fields including biomedical, pharmaceutical, and environmental areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparison of transferrin isoform analysis by capillary electrophoresis and HPLC for screening congenital disorders of glycosylation.

    PubMed

    Dave, Mihika B; Dherai, Alpa J; Udani, Vrajesh P; Hegde, Anaita U; Desai, Neelu A; Ashavaid, Tester F

    2018-01-01

    Transferrin, a major glycoprotein has different isoforms depending on the number of sialic acid residues present on its oligosaccharide chain. Genetic variants of transferrin as well as the primary (CDG) & secondary glycosylation defects lead to an altered transferrin pattern. Isoform analysis methods are based on charge/mass variations. We aimed to compare the performance of commercially available capillary electrophoresis CDT kit for diagnosing congenital disorders of glycosylation with our in-house optimized HPLC method for transferrin isoform analysis. The isoform pattern of 30 healthy controls & 50 CDG-suspected patients was determined by CE using a Carbohydrate-Deficient Transferrin kit. The results were compared with in-house HPLC-based assay for transferrin isoforms. Transferrin isoform pattern for healthy individuals showed a predominant tetrasialo transferrin fraction followed by pentasialo, trisialo, and disialotransferrin. Two of 50 CDG-suspected patients showed the presence of asialylated isoforms. The results were comparable with isoform pattern obtained by HPLC. The commercial controls showed a <20% CV for each isoform. Bland Altman plot showed the difference plot to be within +1.96 with no systemic bias in the test results by HPLC & CE. The CE method is rapid, reproducible and comparable with HPLC and can be used for screening Glycosylation defects. © 2017 Wiley Periodicals, Inc.

  18. Comparison of the BioRad Variant and Primus Ultra2 high-pressure liquid chromatography (HPLC) instruments for the detection of variant hemoglobins.

    PubMed

    Gosselin, R C; Carlin, A C; Dwyre, D M

    2011-04-01

    Hemoglobin variants are a result of genetic changes resulting in abnormal or dys-synchronous hemoglobin chain production (thalassemia) or the generation of hemoglobin chain variants such as hemoglobin S. Automated high-pressure liquid chromatography (HPLC) systems have become the method of choice for the evaluation of patients suspected with hemoglobinopathies. In this study, we evaluated the performance of two HPLC methods used in the detection of common hemoglobin variants: Variant and Ultra2. There were 377 samples tested, 26% (99/377) with HbS, 8.5% (32/377) with HbC, 20.7% (78/377) with other hemoglobin variant or thalassemia, and 2.9% with increased hemoglobin A(1) c. The interpretations of each chromatograph were compared. There were no differences noted for hemoglobins A(0), S, or C. There were significant differences between HPLC methods for hemoglobins F, A(2), and A(1) c. However, there was good concordance between normal and abnormal interpretations (97.9% and 96.2%, respectively). Both Variant and Ultra2 HPLC methods were able to detect most common hemoglobin variants. There was better discrimination for fast hemoglobins, between hemoglobins E and A(2), and between hemoglobins S and F using the Ultra2 HPLC method. © 2010 Blackwell Publishing Ltd.

  19. Comparison of the phenolic composition of fruit juices by single step gradient HPLC analysis of multiple components versus multiple chromatographic runs optimised for individual families.

    PubMed

    Bremner, P D; Blacklock, C J; Paganga, G; Mullen, W; Rice-Evans, C A; Crozier, A

    2000-06-01

    After minimal sample preparation, two different HPLC methodologies, one based on a single gradient reversed-phase HPLC step, the other on multiple HPLC runs each optimised for specific components, were used to investigate the composition of flavonoids and phenolic acids in apple and tomato juices. The principal components in apple juice were identified as chlorogenic acid, phloridzin, caffeic acid and p-coumaric acid. Tomato juice was found to contain chlorogenic acid, caffeic acid, p-coumaric acid, naringenin and rutin. The quantitative estimates of the levels of these compounds, obtained with the two HPLC procedures, were very similar, demonstrating that either method can be used to analyse accurately the phenolic components of apple and tomato juices. Chlorogenic acid in tomato juice was the only component not fully resolved in the single run study and the multiple run analysis prior to enzyme treatment. The single run system of analysis is recommended for the initial investigation of plant phenolics and the multiple run approach for analyses where chromatographic resolution requires improvement.

  20. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  1. Advances in HPLC-ICP-MS interface techniques for metal speciation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, S.J.

    The relentless demand for lower detection limits is increasingly coupled to the requirement for elemental speciation. This is particularly true in environmental and clinical fields where total levels are often insufficient for mobility and toxicity studies. This demand for both qualitative and quantitative data on the individual species present in complex samples has led to the development of various interfaces to couple some form of chromatography, usually gas chromatography (GC) or high performance liquid chromatography (HPLC) to an element specific detector. Today inductively coupled plasma-mass spectrometry is often employed since it offers excellent detection limits, element specific information (including isotopicmore » data) and the potential for multi-element studies. Ms presentation will concentrate on HPLC couplings although the advantages and disadvantages of both GC and HPLC couplings to ICP-MS will be discussed. Particular attention will be given to the optimization of both the chromatography and detection systems. Details will be presented of several successful HPLC interface designs and ways of facilitating high levels of a range of organic solvents (e.g. methanol and THF) in the HPLC mobile phase will be highlighted. The advantages of using a sheath gas and practical ways of achieving this will also be discussed. Finally the use of isotope dilution analysis in conjunction with HPLC-ICP-MS will be outlined. In all cases the impact of using the most appropriate approach will be demonstrated using both environmental and clinical samples.« less

  2. Separation and preparation of xanthochymol and guttiferone E by high performance liquid chromatography and high speed counter-current chromatography combined with silver nitrate coordination reaction.

    PubMed

    Li, Jun; Gao, Ruixi; Zhao, Dan; Huang, Xianju; Chen, Yu; Gan, Fei; Liu, Hui; Yang, Guangzhong

    2017-08-18

    Xanthochymol (XCM) and guttiferone E (GFE), a pair of π bond benzophenone isomers from Garcinia xanthochymus, were once reported to be difficult or impossible to separate. The present study reports the successful separation of these two isomers through high performance liquid chromatography (HPLC), as well as their effective isolation using high speed counter-current chromatography (HSCCC) based on the silver nitrate (AgNO 3 ) coordination reaction. First, an effective HPLC separation system was developed, achieving a successful baseline separation with resolution of 2.0. Based on the partition coefficient (K) resolved by HPLC, the two-phase solvent system was determined as n-hexane, methanol and water with the uncommon volume ratio of 4:6:1. A crude extract of Garcinia xanthochymus (0.2g) was purified by normal HSCCC and refined with AgNO 3 -HSCCC. Monomers of XCM and GFE were identified by HPLC, mass spectrometry (MS) and nuclear magnetic resonance (NMR). The results demonstrate the separation and isolation of π bond benzophenone isomers using ordinary octadecyl silane (C 18 ) columns and HSCCC. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Quality Analysis of Chlorogenic Acid and Hyperoside in Crataegi fructus

    PubMed Central

    Weon, Jin Bae; Jung, Youn Sik; Ma, Choong Je

    2016-01-01

    Background: Crataegi fructus is a herbal medicine for strong stomach, sterilization, and alcohol detoxification. Chlorogenic acid and hyperoside are the major compounds in Crataegi fructus. Objective: In this study, we established novel high-performance liquid chromatography (HPLC)-diode array detection analysis method of chlorogenic acid and hyperoside for quality control of Crataegi fructus. Materials and Methods: HPLC analysis was achieved on a reverse-phase C18 column (5 μm, 4.6 mm × 250 mm) using water and acetonitrile as mobile phase with gradient system. The method was validated for linearity, precision, and accuracy. About 31 batches of Crataegi fructus samples collected from Korea and China were analyzed by using HPLC fingerprint of developed HPLC method. Then, the contents of chlorogenic acid and hyperoside were compared for quality evaluation of Crataegi fructus. Results: The results have shown that the average contents (w/w %) of chlorogenic acid and hyperoside in Crataegi fructus collected from Korea were 0.0438% and 0.0416%, respectively, and the average contents (w/w %) of 0.0399% and 0.0325%, respectively. Conclusion: In conclusion, established HPLC analysis method was stable and could provide efficient quality evaluation for monitoring of commercial Crataegi fructus. SUMMARY Quantitative analysis method of chlorogenic acid and hyperoside in Crataegi fructus is developed by high.performance liquid chromatography.(HPLC).diode array detectionEstablished HPLC analysis method is validated with linearity, precision, and accuracyThe developed method was successfully applied for quantitative analysis of Crataegi fructus sample collected from Korea and China. Abbreviations used: HPLC: High-performance liquid chromatography, GC: Gas chromatography, MS: Mass spectrometer, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation, RRT: Relative retention time, RPA: Relation peak area. PMID:27076744

  4. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    NASA Astrophysics Data System (ADS)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  5. Direct characterization of aqueous extract of Hibiscus sabdariffa using HPLC with diode array detection coupled to ESI and ion trap MS.

    PubMed

    Rodríguez-Medina, Inmaculada C; Beltrán-Debón, Raúl; Molina, Vicente Micol; Alonso-Villaverde, Carlos; Joven, Jorge; Menéndez, Javier A; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2009-10-01

    The phenolic fraction and other polar compounds of the Hibiscus sabdariffa were separated and identified by HPLC with diode array detection coupled to electrospray TOF and IT tandem MS (DAD-HPLC-ESI-TOF-MS and IT-MS). The H. sabdariffa aqueous extract was filtered and directly injected into the LC system. The analysis of the compounds was carried out by RP HPLC coupled to DAD and TOF-MS in order to obtain molecular formula and exact mass. Posterior analyses with IT-MS were performed and the fragmentation pattern and confirmation of the structures were achieved. The H. sabdariffa samples were successfully analyzed in positive and negative ionization modes with two optimized linear gradients. In positive mode, the two most representative anthocyanins and other compounds were identified whereas the phenolic fraction, hydroxycitric acid and its lactone were identified using the negative ionization mode.

  6. PREPARATIVE ISOLATION AND PURIFICATION OF CHEMICAL CONSTITUENTS OF BELAMCANDA BY MPLC, HSCCC AND PREP-HPLC

    PubMed Central

    Wang, Xiaohong; Liang, Yong; Peng, Cuilin; Xie, Huichun; Pan, Man; Zhang, Tianyou; Ito, Yoichiro

    2010-01-01

    Combined with medium-pressure liquid chromatography (MPLC) and preparative high-pressure liquid chromatography (Prep-HPLC), high-speed countercurrent chromatography (HSCCC) was successfully applied for separation and purification of isoflavonoids from the extract of belamcanda. HSCCC separation was performed on a two-phase solvent system composed of methyl tert-butyl ether -ethyl acetate - n-butyl alcohol – acetonitrile −0.1% aqueous trifluoroacetic acid at a volume radio of 1:2:1:1:5. Semi-purified peak fractions from HSCCC separation were further purified by Prep-HPLC. Nine well-separated fractions were analyzed by HPLC-UV absorption spectrometry to determine their purities and characterized with ESI-MSn. Except for peaksland VII (unknown) seven compounds were identified as apocynin (peak II), mangiferin (peak III), 7-O-methylmangiferin (peak IV), hispidulin (peak V), 3′-hydroxyltectoridin (peak VI), iristectorin B (peak VII), isoiridin (peak IX). PMID:21552369

  7. Leukotriene B4 catabolism: quantitation of leukotriene B4 and its omega-oxidation products by reversed-phase high-performance liquid chromatography.

    PubMed

    Shak, S

    1987-01-01

    LTB4 and its omega-oxidation products may be rapidly, sensitively, and specifically quantitated by the methods of solid-phase extraction and reversed-phase high-performance liquid chromatography (HPLC), which are described in this chapter. Although other techniques, such as radioimmunoassay or gas chromatography-mass spectrometry, may be utilized for quantitative analysis of the lipoxygenase products of arachidonic acid, only the technique of reversed-phase HPLC can quantitate as many as 10 metabolites in a single analysis, without prior derivatization. In this chapter, we also reviewed the chromatographic theory which we utilized in order to optimize reversed-phase HPLC analysis of LTB4 and its omega-oxidation products. With this information and a gradient HPLC system, it is possible for any investigator to develop a powerful assay for the potent inflammatory mediator, LTB4, or for any other lipoxygenase product of arachidonic acid.

  8. Automated solid-phase extraction coupled online with HPLC-FLD for the quantification of zearalenone in edible oil.

    PubMed

    Drzymala, Sarah S; Weiz, Stefan; Heinze, Julia; Marten, Silvia; Prinz, Carsten; Zimathies, Annett; Garbe, Leif-Alexander; Koch, Matthias

    2015-05-01

    Established maximum levels for the mycotoxin zearalenone (ZEN) in edible oil require monitoring by reliable analytical methods. Therefore, an automated SPE-HPLC online system based on dynamic covalent hydrazine chemistry has been developed. The SPE step comprises a reversible hydrazone formation by ZEN and a hydrazine moiety covalently attached to a solid phase. Seven hydrazine materials with different properties regarding the resin backbone, pore size, particle size, specific surface area, and loading have been evaluated. As a result, a hydrazine-functionalized silica gel was chosen. The final automated online method was validated and applied to the analysis of three maize germ oil samples including a provisionally certified reference material. Important performance criteria for the recovery (70-120 %) and precision (RSDr <25 %) as set by the Commission Regulation EC 401/2006 were fulfilled: The mean recovery was 78 % and RSDr did not exceed 8 %. The results of the SPE-HPLC online method were further compared to results obtained by liquid-liquid extraction with stable isotope dilution analysis LC-MS/MS and found to be in good agreement. The developed SPE-HPLC online system with fluorescence detection allows a reliable, accurate, and sensitive quantification (limit of quantification, 30 μg/kg) of ZEN in edible oils while significantly reducing the workload. To our knowledge, this is the first report on an automated SPE-HPLC method based on a covalent SPE approach.

  9. Two-dimensional multi-heart cutting centrifugal partition chromatography-liquid chromatography for the preparative isolation of antioxidants from Edelweiss plant.

    PubMed

    Marlot, Léa; Batteau, Magali; Escofet, Marie-Claire; Nuccio, Sylvie; Coquoin, Véronique; De Vaumas, René; Faure, Karine

    2017-06-30

    The Edelweiss plant has been recognized as a very valuable source of anti-aging principles due to its composition of antioxidants compounds: leontopodic acid A and 3,5-dicaffeoylquinic acid. In this work, off-line multi-heart cutting CPC-LC separation was set up at industrial scale in order to isolate and produce new high quality reference material of these two antioxidants from Edelweiss. For this purpose, CPC and HPLC methods were developed and optimized at laboratory scale and a comprehensive CPCxHPLC analysis of the crude extract was established. Thereby, the CPC method led to a first separation of the target compounds according to their partition coefficient in the solvent system and the HPLC method was performed on the recovered fractions to lead to a second separation. A 2D CPCxHPLC plot was established in order to know the fractions to select at the industrial scale. Then, the CPC and HPLC methods were transferred at industrial scale and the multi-heart cutting CPC-LC was performed in off-line mode. Using CPC with methyl ter-butyl ether-water 1:1 (v/v) solvent system and LC with Denali C18 column, 2g of crude extract sample were injected and leontopodic acid A and 3,5-dicaffeoylquinic acid were recovered with purity over 97%. The compounds were identified by MS and NMR. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Use of an online extraction liquid chromatography quadrupole time-of-flight tandem mass spectrometry method for the characterization of polyphenols in Citrus paradisi cv. Changshanhuyu peel.

    PubMed

    Tong, Chaoying; Peng, Mijun; Tong, Runna; Ma, Ruyi; Guo, Keke; Shi, Shuyun

    2018-01-19

    Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction of Citrus paradisi cv. Changshanhuyu (Changshanhuyu) peel, OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of twenty-two secondary metabolites were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and nine of them were discovered in Changshanhuyu peel for the first time to our knowledge. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Online extraction-high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry for rapid flavonoid profiling of Fructus aurantii immaturus.

    PubMed

    Tong, Runna; Peng, Mijun; Tong, Chaoying; Guo, Keke; Shi, Shuyun

    2018-03-01

    Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction for Fructus aurantii immaturus (Zhishi), OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of eighteen flavonoids were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and compound 9, natsudaidain-3-O-glucoside, was discovered in Zhishi for the first time. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2018. Published by Elsevier B.V.

  12. The Assessment of Liver Reserve Function by Spectrophotometry based on Determination of Phenacetin and Paracetamol.

    PubMed

    Ren, Rui; Ma, Yongmei; Ma, Wanshan; Lu, Sumei

    2015-01-01

    To establish a technical system for assessing liver reserve function based on spectrophotometry by detection of phenacetin and paracetamol in blood samples. Taking detected contents of phenacetin and paracetamol by high performance liquid chromatography (HPLC) as standard, which was proved to be able to detect drug concentrations with high resolution and accuracy, we established a technical system based on the spectrophotometric technique to assay phenacetin and paracetamol, including the color system, the maximum absorption wavelength, the influence factors of color system, and the optimal conditions for hydrolysis. Then we verified our established system compared with that under HPLC by recovery test. This study established a technical system to detect phenacetin and paracetamol in blood samples using spectrophotometry. Mainly, 3 mol/L hydrochloric acid (HCl) was added to samples for hydrolysis for 30 minutes, then, adding 0.02% 1,2-naphthoquinone-4-sulfonate (NQS), 1% cetyltrimethyl ammonium bromide (CTA) and 2% sodium hydroxide (or 3% sodium carbonate) (ratio of 1:6:1:2 or 3), and the absorbance was measured at 500 nm and 570 nm to calculate their concentrations. Using an established spectrophotometric system to detect phenacetin and paracetamol in blood samples could assess liver reserve function, which was proved comparable with HPLC in resolution and repeatability.

  13. Detection of basal acetylcholine release in the microdialysis of rat frontal cortex by high-performance liquid chromatography using a horseradish peroxidase-osmium redox polymer electrode with pre-enzyme reactor.

    PubMed

    Kato, T; Liu, J K; Yamamoto, K; Osborne, P G; Niwa, O

    1996-06-28

    To determine the basal acetylcholine level in the dialysate of rat frontal cortex, a horseradish peroxidase-osmium redox polymer-modified glassy carbon electrode (HRP-GCE) was employed instead of the conventional platinum electrode used in high-performance liquid chromatography-electrochemical detection (HPLC-ED). In initial experiments, an oxidizable unknown compound interfered with the detection of basal acetylcholine release on HPLC-HRP-GCE. An immobilized peroxidase-choline oxidase precolumn (pre-reactor) was included in the HPLC system, to eliminate the interference from the unknown compound. This combination could detect less than 10 fmol of standard acetylcholine and basal acetylcholine levels in the dialysate from a conventional concentric design microdialysis probe, without the use of cholinesterase inhibitor, and may facilitate physiological investigation of cholinergic neuronal activity in the central nervous system.

  14. Validation of GC and HPLC systems for residue studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, M.

    1995-12-01

    For residue studies, GC and HPLC system performance must be validated prior to and during use. One excellent measure of system performance is the standard curve and associated chromatograms used to construct that curve. The standard curve is a model of system response to an analyte over a specific time period, and is prima facia evidence of system performance beginning at the auto sampler and proceeding through the injector, column, detector, electronics, data-capture device, and printer/plotter. This tool measures the performance of the entire chromatographic system; its power negates most of the benefits associated with costly and time-consuming validation ofmore » individual system components. Other measures of instrument and method validation will be discussed, including quality control charts and experimental designs for method validation.« less

  15. A sensitive and rapid assay for 4-aminophenol in paracetamol drug and tablet formulation, by flow injection analysis with spectrophotometric detection.

    PubMed

    Bloomfield, M S

    2002-12-06

    4-Aminophenol (4AP) is the primary degradation product of paracetamol which is limited at a low level (50 ppm or 0.005% w/w) in the drug substance by the European, United States, British and German Pharmacopoeias, employing a manual colourimetric limit test. The 4AP limit is widened to 1000 ppm or 0.1% w/w for the tablet product monographs, which quote the use of a less sensitive automated HPLC method. The lower drug substance specification limit is applied to our products, (50 ppm, equivalent to 25 mug 4AP in a tablet containing 500-mg paracetamol) and the pharmacopoeial HPLC assay was not suitable at this low level due to matrix interference. For routine analysis a rapid, automated assay was required. This paper presents a highly sensitive, precise and automated method employing the technique of Flow Injection (FI) analysis to quantitatively assay low levels of this degradant. A solution of the drug substance, or an extract of the tablets, containing 4AP and paracetamol is injected into a solvent carrier stream and merged on-line with alkaline sodium nitroprusside reagent, to form a specific blue derivative which is detected spectrophotometrically at 710 nm. Standard HPLC equipment is used throughout. The procedure is fully quantitative and has been optimised for sensitivity and robustness using a multivariate experimental design (multi-level 'Central Composite' response surface) model. The method has been fully validated and is linear down to 0.01 mug ml(-1). The approach should be applicable to a range of paracetamol products.

  16. Quality of the antimalarial medicine artemether - lumefantrine in eight cities of the Democratic Republic of the Congo.

    PubMed

    Mufusama, Jean-Pierre; Ioset, Karine Ndjoko; Feineis, Doris; Hoellein, Ludwig; Holzgrabe, Ulrike; Bringmann, Gerhard

    2018-06-12

    In the context of post-marketing surveillance supporting public-health authorities to take evidence-based decisions to fight the spread of poor-quality medicines, the quality of antimalarial artemether-lumefantrine (AL) medicines was assessed in the Democratic Republic of the Congo (DRC). A total of 150 samples of AL containing products was collected from private pharmaceutical outlets in eight main cities: Goma, Kikwit, Kinshasa, Kisangani, Lubumbashi, Matadi, Mbandaka, and Mbuji-Mayi. All drug samples were successively analyzed by visual inspection, thin-layer chromatography (TLC), and high-performance liquid chromatography (HPLC) following The International Pharmacopoeia. Out of the 150 collected drug samples, three (2%) failed the visual inspection as they had shelf lives different from those of other samples with the same brand name. Four samples (2.7%) did not pass the TLC test as they contained only one or even none of the two declared active pharmaceutical ingredients (APIs). HPLC assays showed that 46 (30.7%) samples had artemether contents below 90% and 17 (11.3%) above 110% of the content claimed on the label. For lumefantrine, 32 (21.7%) samples had contents below 90%, and eight (5.3%) had contents above 110%. This survey in DRC gives evidence that poor-quality antimalarial medicines are widely present. Based on three detection techniques, the study shows the necessity to equip developing countries with modern techniques such as HPLC, which, if combined with affordable techniques like TLC, could provide a pertinent analytical strategy to combat drug counterfeiting and poor manufacturing. This article is protected by copyright. All rights reserved.

  17. Comprehensive characterizations of nanoparticle biodistribution following systemic injection in mice

    NASA Astrophysics Data System (ADS)

    Liao, Wei-Yin; Li, Hui-Jing; Chang, Ming-Yao; Tang, Alan C. L.; Hoffman, Allan S.; Hsieh, Patrick C. H.

    2013-10-01

    Various nanoparticle (NP) properties such as shape and surface charge have been studied in an attempt to enhance the efficacy of NPs in biomedical applications. When trying to undermine the precise biodistribution of NPs within the target organs, the analytical method becomes the determining factor in measuring the precise quantity of distributed NPs. High performance liquid chromatography (HPLC) represents a more powerful tool in quantifying NP biodistribution compared to conventional analytical methods such as an in vivo imaging system (IVIS). This, in part, is due to better curve linearity offered by HPLC than IVIS. Furthermore, HPLC enables us to fully analyze each gram of NPs present in the organs without compromising the signals and the depth-related sensitivity as is the case in IVIS measurements. In addition, we found that changing physiological conditions improved large NP (200-500 nm) distribution in brain tissue. These results reveal the importance of selecting analytic tools and physiological environment when characterizing NP biodistribution for future nanoscale toxicology, therapeutics and diagnostics.Various nanoparticle (NP) properties such as shape and surface charge have been studied in an attempt to enhance the efficacy of NPs in biomedical applications. When trying to undermine the precise biodistribution of NPs within the target organs, the analytical method becomes the determining factor in measuring the precise quantity of distributed NPs. High performance liquid chromatography (HPLC) represents a more powerful tool in quantifying NP biodistribution compared to conventional analytical methods such as an in vivo imaging system (IVIS). This, in part, is due to better curve linearity offered by HPLC than IVIS. Furthermore, HPLC enables us to fully analyze each gram of NPs present in the organs without compromising the signals and the depth-related sensitivity as is the case in IVIS measurements. In addition, we found that changing physiological conditions improved large NP (200-500 nm) distribution in brain tissue. These results reveal the importance of selecting analytic tools and physiological environment when characterizing NP biodistribution for future nanoscale toxicology, therapeutics and diagnostics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr03954d

  18. Biomanufacturing process analytical technology (PAT) application for downstream processing: Using dissolved oxygen as an indicator of product quality for a protein refolding reaction.

    PubMed

    Pizarro, Shelly A; Dinges, Rachel; Adams, Rachel; Sanchez, Ailen; Winter, Charles

    2009-10-01

    Process analytical technology (PAT) is an initiative from the US FDA combining analytical and statistical tools to improve manufacturing operations and ensure regulatory compliance. This work describes the use of a continuous monitoring system for a protein refolding reaction to provide consistency in product quality and process performance across batches. A small-scale bioreactor (3 L) is used to understand the impact of aeration for refolding recombinant human vascular endothelial growth factor (rhVEGF) in a reducing environment. A reverse-phase HPLC assay is used to assess product quality. The goal in understanding the oxygen needs of the reaction and its impact to quality, is to make a product that is efficiently refolded to its native and active form with minimum oxidative degradation from batch to batch. Because this refolding process is heavily dependent on oxygen, the % dissolved oxygen (DO) profile is explored as a PAT tool to regulate process performance at commercial manufacturing scale. A dynamic gassing out approach using constant mass transfer (k(L)a) is used for scale-up of the aeration parameters to manufacturing scale tanks (2,000 L, 15,000 L). The resulting DO profiles of the refolding reaction show similar trends across scales and these are analyzed using rpHPLC. The desired product quality attributes are then achieved through alternating air and nitrogen sparging triggered by changes in the monitored DO profile. This approach mitigates the impact of differences in equipment or feedstock components between runs, and is directly inline with the key goal of PAT to "actively manage process variability using a knowledge-based approach." (c) 2009 Wiley Periodicals, Inc.

  19. Rapid determination of sugar level in snack products using infrared spectroscopy.

    PubMed

    Wang, Ting; Rodriguez-Saona, Luis E

    2012-08-01

    Real-time spectroscopic methods can provide a valuable window into food manufacturing to permit optimization of production rate, quality and safety. There is a need for cutting edge sensor technology directed at improving efficiency, throughput and reliability of critical processes. The aim of the research was to evaluate the feasibility of infrared systems combined with chemometric analysis to develop rapid methods for determination of sugars in cereal products. Samples were ground and spectra were collected using a mid-infrared (MIR) spectrometer equipped with a triple-bounce ZnSe MIRacle attenuated total reflectance accessory or Fourier transform near infrared (NIR) system equipped with a diffuse reflection-integrating sphere. Sugar contents were determined using a reference HPLC method. Partial least squares regression (PLSR) was used to create cross-validated calibration models. The predictability of the models was evaluated on an independent set of samples and compared with reference techniques. MIR and NIR spectra showed characteristic absorption bands for sugars, and generated excellent PLSR models (sucrose: SEP < 1.7% and r > 0.96). Multivariate models accurately and precisely predicted sugar level in snacks allowing for rapid analysis. This simple technique allows for reliable prediction of quality parameters, and automation enabling food manufacturers for early corrective actions that will ultimately save time and money while establishing a uniform quality. The U.S. snack food industry generates billions of dollars in revenue each year and vibrational spectroscopic methods combined with pattern recognition analysis could permit optimization of production rate, quality, and safety of many food products. This research showed that infrared spectroscopy is a powerful technique for near real-time (approximately 1 min) assessment of sugar content in various cereal products. © 2012 Institute of Food Technologists®

  20. Regio- and stereospecific analysis of glycerolipids.

    PubMed

    Kuksis, Arnis; Itabashi, Yutaka

    2005-06-01

    In recent years researchers have recognized the potential value of comprehensive lipid profiling (lipidomics), which was invented and promoted by lipidologists who recognized the many valuable applications that grew out of the fields of DNA profiling (genomics) and protein profiling (proteonomics). Through lipid class-selective intrasource ionization and subsequent analysis of two-dimensional cross-peak intensities, the chemical identity and mass composition of individual molecular species of most lipid classes can now be determined in a chloroform extract. There remains, however, the necessity to distinguish the enantiomers and isobaric regioisomers resulting from enzymatic and chemical reactions, which conventional high performance liquid chromatography/mass spectrometry (HPLC/MS) has been slow to accommodate, and tandem MS unable to provide. While reversed-phase HPLC can separate regioisomers, normal-phase HPLC can resolve diastereomers, and chiral-phase HPLC can effect dramatic resolution of enantiomers, the full potential of the combined systems has seldom been exploited. The present chapter calls attention to both recent and earlier combinations of these methodologies with mass spectrometry, which allows the HPLC/ESI (electrospray ionization)-MS/MS separation and identification of enantiomeric diacylglycerols, triacylglycerols, and glycerophospholipids as well as their isobaric regioisomers. These developments permit further expansion of lipid profiling (lipidomics) and better understanding of lipid metabolism.

  1. Synthesis and characterization of nanometric zinc oxide for a stationary phase in liquid chromatography

    NASA Astrophysics Data System (ADS)

    Gordillo-Delgado, F.; Soto-Barrera, C. C.; Plazas-Saldaña, J.

    2017-01-01

    The increasing demand for equipment to remove organic compounds in industry and research activity has led to evaluate nanometric zinc oxide (ZnO). In this work, we present the ZnO nanoparticles synthesis for reusing of discarded columns, as a low-cost alternative. The compound was obtained by sol-gel technique using zinc chloride and sodium hydroxide as precursors and a drying temperature of 169°C. An X-ray diffractometer was used to estimate the average particle size at 20.3±0.2nm the adsorption capacity was 0.0144L/g and the chemical resistance was tested with HCl and NaOH. The ZnO nanopowder was packed with 100psi pressure in an empty C-18 column cavity. The column packing resolution was evaluated using a high performance liquid chromatographer (HPLC-Thermo Scientific Dionex UltiMate 3000); using a caffeine standard, the following parameters were established: solvent flow: 1.2mL/min, average column temperature: 40°C, running time: 10 minutes, mobile phase acetonitrile-water composition (9:1). These results validate the potential of ZnO nanopowder as a column packing material in HPLC technique.

  2. The contribution of Raman spectroscopy to the analytical quality control of cytotoxic drugs in a hospital environment: eliminating the exposure risks for staff members and their work environment.

    PubMed

    Bourget, Philippe; Amin, Alexandre; Vidal, Fabrice; Merlette, Christophe; Troude, Pénélope; Baillet-Guffroy, Arlette

    2014-08-15

    The purpose of the study was to perform a comparative analysis of the technical performance, respective costs and environmental effect of two invasive analytical methods (HPLC and UV/visible-FTIR) as compared to a new non-invasive analytical technique (Raman spectroscopy). Three pharmacotherapeutic models were used to compare the analytical performances of the three analytical techniques. Statistical inter-method correlation analysis was performed using non-parametric correlation rank tests. The study's economic component combined calculations relative to the depreciation of the equipment and the estimated cost of an AQC unit of work. In any case, analytical validation parameters of the three techniques were satisfactory, and strong correlations between the two spectroscopic techniques vs. HPLC were found. In addition, Raman spectroscopy was found to be superior as compared to the other techniques for numerous key criteria including a complete safety for operators and their occupational environment, a non-invasive procedure, no need for consumables, and a low operating cost. Finally, Raman spectroscopy appears superior for technical, economic and environmental objectives, as compared with the other invasive analytical methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmapsmore » of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.« less

  4. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography.

    PubMed

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida.

  5. Comparison of UHPLC and HPLC in benzodiazepines analysis of postmortem samples: a case-control study.

    PubMed

    Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein

    2015-04-01

    The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case-control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis.

  6. Rapid, Standardized Method for Determination of Mycobacterium tuberculosis Drug Susceptibility by Use of Mycolic Acid Analysis▿

    PubMed Central

    Parrish, Nicole; Osterhout, Gerard; Dionne, Kim; Sweeney, Amy; Kwiatkowski, Nicole; Carroll, Karen; Jost, Kenneth C.; Dick, James

    2007-01-01

    Multidrug-resistant (MDR) Mycobacterium tuberculosis and extrensively drug-resistant (XDR) M. tuberculosis are emerging public health threats whose threats are compounded by the fact that current techniques for testing the susceptibility of M. tuberculosis require several days to weeks to complete. We investigated the use of high-performance liquid chromatography (HPLC)-based quantitation of mycolic acids as a means of rapidly determining drug resistance and susceptibility in M. tuberculosis. Standard susceptibility testing and determination of the MICs of drug-susceptible (n = 26) and drug-resistant M. tuberculosis strains, including MDR M. tuberculosis strains (n = 34), were performed by using the Bactec radiometric growth system as the reference method. The HPLC-based susceptibilities of the current first-line drugs, isoniazid (INH), rifampin (RIF), ethambutol (EMB), and pyrazinamide (PZA), were determined. The vials were incubated for 72 h, and aliquots were removed for HPLC analysis by using the Sherlock mycobacterial identification system. HPLC quantitation of total mycolic acid peaks (TMAPs) was performed with treated and untreated cultures. At 72 h, the levels of agreement of the HPLC method with the reference method were 99.5% for INH, EMB, and PZA and 98.7% for RIF. The inter- and intra-assay reproducibilities varied by drug, with an average precision of 13.4%. In summary, quantitation of TMAPs is a rapid, sensitive, and accurate method for antibiotic susceptibility testing of all first-line drugs currently used against M. tuberculosis and offers the potential of providing susceptibility testing results within hours, rather than days or weeks, for clinical M. tuberculosis isolates. PMID:17913928

  7. Comparison of UHPLC and HPLC in Benzodiazepines Analysis of Postmortem Samples

    PubMed Central

    Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein

    2015-01-01

    Abstract The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case–control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis. PMID:25860209

  8. Monitoring of multiple bacteriocins through a developed dual extraction protocol and comparison of HPLC-DAD with turbidometry as their quantification system.

    PubMed

    Katharopoulos, Efstathios; Touloupi, Katerina; Touraki, Maria

    2016-08-01

    The present study describes the development of a simple and efficient screening system that allows identification and quantification of nine bacteriocins produced by Lactococcus lactis. Cell-free L. lactis extracts presented a broad spectrum of antibacterial activity, including Gram-negative bacteria, Gram-positive bacteria, and fungi. The characterization of their sensitivity to pH, and heat, showed that the extracts retained their antibacterial activity at extreme pH values and in a wide temperature range. The loss of antibacterial activity following treatment of the extracts with lipase or protease suggests a lipoproteinaceous nature of the produced antimicrobials. The extracts were subjected to a purification protocol that employs a two phase extraction using ammonium sulfate precipitation and organic solvent precipitation, followed by ion exchange chromatography, solid phase extraction and HPLC. In the nine fractions that presented antimicrobial activity, bacteriocins were quantified by the turbidometric method using a standard curve of nisin and by the HPLC method with nisin as the external standard, with both methods producing comparable results. Turbidometry appears to be unique in the qualitative determination of bacteriocins but the only method suitable to both separate and quantify the bacteriocins providing increased sensitivity, accuracy, and precision is HPLC. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Application of solid-phase microextraction in the investigation of protein binding of pharmaceuticals.

    PubMed

    Theodoridis, Georgios

    2006-01-18

    Protein-drug interactions of seven common pharmaceuticals were studied using solid-phase microextraction (SPME). SPME can be used in such investigations on the condition that no analyte depletion occurs. In multi-compartment systems (e.g. a proteinaceous matrix) only the free portion of the analyte is able to partition into the SPME fiber. In addition if no sample depletion occurs, the bound drug-free drug equilibria are not disturbed. In the present study seven pharmaceuticals (quinine, quinidine, naproxen, ciprofloxacin, haloperidol, paclitaxel and nortriptyline) were assayed by SPME. For quantitative purposes SPME was validated first in the absence of proteins. Calibration curves were constructed for each drug by HPLC-fluorescence and HPLC-UV analysis. SPME was combined to HPLC off-line, desorption occurring in HPLC inserts filled with 200 microL methanol. Binding of each drug to human serum albumin was studied independently. Experimental results were in agreement with literature data and ultrafiltration experiments, indicating the feasibility of the method for such bioanalytical purposes.

  10. Determination of Two Sulfonylurea Herbicides Residues in Soil Environment Using HPLC and Phytotoxicity of These Herbicides by Lentil Bioassay.

    PubMed

    Mehdizadeh, Mohammad; Alebrahim, Mohammad Taghi; Roushani, Mahmoud

    2017-07-01

    A HPLC-UV detection system was used for determination of sulfosulfuron and tribenuron methyl residues from soils. The soils were fortified with sulfosulfuron and tribenuron methyl at rates of 26 and 15 g a.i. ha -1 respectively and samples were taken randomly on 0 (2 h), 1, 2, 4, 10, 20, 40, 60, 90 and 120 days after treatment. The final extracts were prepared for analysis by HPLC. The results showed that degradation of both herbicides in the silty loam soil was faster than sandy loam soil. Half-life of sulfosulfuron was ranged from 5.37 to 10.82 days however this value for tribenuron methyl was ranged from 3.23 to 5.72 days on different soils. The residue of both herbicides at 120 days after application in wheat field had no toxicitic effect on lentil. It was concluded that HPLC analysis procedure was an appropriate method for determination of these herbicides from soils.

  11. The integrated quality assessment of Chinese commercial dry red wine based on a method of online HPLC-DAD-CL combined with HPLC-ESI-MS.

    PubMed

    Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin

    2014-07-01

    To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  12. Effectiveness of quenchers to reduce radiolysis of (111)In- or (177)Lu-labelled methionine-containing regulatory peptides. Maintaining radiochemical purity as measured by HPLC.

    PubMed

    de Blois, Erik; Chan, Ho Sze; Konijnenberg, Mark; de Zanger, Rory; Breeman, Wouter A P

    2012-01-01

    An overview how to measure and to quantify radiolysis by the addition of quenchers and to maintain Radio-Chemical Purity (RCP) of vulnerable methionine-containing regulatory peptides is presented. High RCP was only achieved with a combination of quenchers. However, quantification of RCP is not standardized, and therefore comparison of radiolabelling and RCP of regulatory peptides between different HPLC-systems and between laboratories is cumbersome. Therefore we suggest a set of standardized requirements to quantify RCP by HPLC for radiolabelled DTPA- or DOTA-peptides. Moreover, a dosimetry model was developed to calculate the doses in the reaction vials during radiolabelling and storage of the radiopeptides, and to predict RCP in the presence and absence of quenchers. RCP was measured by HPLC, and a relation between radiation dose and radiolysis of RCP was established. The here described quenchers are tested individually as ƒ(concentration) to investigate efficacy to reduce radiolysis of radiolabelled methionine-containing regulatory peptides.

  13. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma.

    PubMed

    Kopec, Rachel E; Schweiggert, Ralf M; Riedl, Ken M; Carle, Reinhold; Schwartz, Steven J

    2013-06-30

    Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma

    PubMed Central

    Kopec, Rachel E.; Schweiggert, Ralf M.; Riedl, Ken M.; Carle, Reinhold; Schwartz, Steven J.

    2013-01-01

    Rationale Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. Methods After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. Results For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. Conclusions HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. PMID:23681818

  15. HPLC-ELSD Quantification and Centrifugal Partition Chromatography Isolation of 8-O-Acetylharpagide from Oxera coronata (Lamiaceae).

    PubMed

    Remeur, Camille; Le Borgne, Erell; Gauthier, Léa; Grougnet, Raphaël; Deguin, Brigitte; Poullain, Cyril; Litaudon, Marc

    2017-05-01

    Iridoid glycosides possess highly functionalised monoterpenoid aglycon with several contiguous stereocentres. For the most common, they are often present in quantities reaching several percentage of the fresh plant weight, and thus they may be regarded as starting material for the synthesis of a number of new chiral and bioactive molecules. To quantify and to isolate 8-O-acetylharpagide (AH) from several extracts of Oxera coronata R.P.J. de Kok, a Lamiaceae species endemic to New Caledonia, using HPLC-ELSD (evaporative light scattering detector) and centrifugal partition chromatography (CPC). Oxera coronata produces high amounts of AH in leaves, twigs and fruits. Water and methanol extracts of these plant parts were prepared. The content of AH in each extract was quantified by HPLC-ELSD, using acetonitrile-water (+0.1% formic acid) gradient elution. The HPLC method was validated for precision, linearity, limit of detection (LOD), limit of quantification (LOQ) and accuracy. A ternary solvent system ethyl acetate/n-propanol/water (3:2:5, v/v/v) was selected and applied to recover the target compound using Spot CPC from the leaves aqueous extract. HPLC-ELSD analysis followed by CPC purification led to the efficient isolation of AH from O. coronata leaves aqueous extract. HPLC-ELSD has proven to be a well-adapted detection and quantification method for iridoid glycosides, while CPC confirmed to be an efficient technique for the isolation of polar compounds. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Liquid chromatography of hydrocarbonaeous quaternary amines on cyclodextrin bonded silica

    USGS Publications Warehouse

    Abidi, S.L.

    1986-01-01

    Mixtures of n-alkylbenzyldimethylammonium chloride (ABDAC) were resolved into homologous components by high-performance liquid chromatography (HPLC) with a cyclodextrin-bonded silica stationary phase. With a few exceptions, results from this study are similar to those obtained from traditional reversed-phase HPLC. It was found that the presence of electrolytes in aqueous mobile phases is not a critical factor in determining the success of HPLC separation. Under normal HPLC conditions, a mobile phase consisting of either methanol–water (50:50) or acetonitrile–water (30:70) was employed for obtaining adequate resolution of the quaternary ammonium mixtures. Although the percent organic modifier–water profiles were similar to those in previous studies with these compounds, resolution (R) and selectivity (α) parameters were found to be quite susceptible to changes in the mobile phase solvent composition. The retention behavior of the cationic analytes in the homologous series is consistent with the hydrophobic-interaction concept proposed for the retention mechanism via dominant inclusion complex formation. Several electrolytes were chosen for a study of the counter ion effect on the chromatographic characteristics of ABDAC components. Among the electrolytes examined, the perchlorate ion was found most likely to act as an ion-pairing counter ion for ammonium cations in the HPLC system studied. A correlation study established linear relationships between the chain length of ABDAC and the logarithmic capacity factor (k2). The analytical utility of the HPLC method was demonstrated by the analysis of various unknown mixtures.

  17. [Synchronous extraction and determination of phenoxy acid herbicides in water by on-line monolithic solid phase microextraction-high performance liquid chromatography].

    PubMed

    Wang, Jiabin; Wu, Fangling; Zhao, Qi

    2015-08-01

    A C18 monolithic capillary column was utilized as the solid phase microextraction column to construct an in-tube SPME-HPLC system which was used to simultaneously extract and detect five phenoxy acid herbicides, including 2,4-dichlorophenoxyacetic acid (2,4-D), 2- (2-chloro)-phenoxy propionic acid (2,2-CPPA), 2-(3-chloro)-phenoxy propionic acid (2,3- CPPA), phenoxy propionic acid (PPA) and 2-(2,4-dichlorophenoxy) propionic acid (2,4-DP). The operating parameters of the in-tube SPME-HPLC system, including the length of the monolithic column, the sampling flow rate, the sampling time, the elution flow rate and the elution time, had been investigated in detail. The optimized operating parameters of the in-tube SPME-HPLC system were as follow: the length of the monolithic column was 20 cm, the sampling flow rate was 0. 04 mL/min, sampling time was 13 min; the elution flow rate was 0.02 mL/min, elution time was 5 min. Under the optimized conditions, the detection limits of the five phenoxy acid herbicides were as follows: 9 µg/L for PPA, 4 µg/L for 2,2-CPPA, 4 µg/L for 2,3-CPPA, 5 µg/L for 2,4-D, 5 µg/L for 2,4-DP. Compared with the HPLC method with direct injection, the combined system showed a good enrichment factors to the analytes. The recoveries of the five phenoxy acid herbicides were between 79.0% and 98.0% (RSD ≤ 3.9%). This method was successfully used to detect the five phenoxy acid herbicides in water samples with satisfactory results.

  18. Instrumental analysis of terminal-conjugated dienes for reexamination of the sex pheromone secreted by a nettle moth, Parasa lepida lepida.

    PubMed

    Islam, M D Azharul; Yamakawa, Rei; Do, Nguyen Duc; Numakura, Naoko; Suzuki, Toshiro; Ando, Tetsu

    2009-05-01

    Conjugated dienyl compounds make one of the main groups of lepidopteran sex pheromones, and GC has been frequently used to determine the configurations of the double bonds. However, the separation of two geometric isomers of a terminal-conjugated diene, such as 7,9-decadien-1-ol secreted by a nettle moth Parasa lepida lepida (Limacodidae), is assumed to be difficult. In order to clarify the chromatographic separation of the terminal dienes, 7,9-decadienyl and 9,11-dodecadienyl compounds (alcohols, acetates, and aldehydes) were analyzed by GC and HPLC. On a capillary GC column, the (E)-isomers flowed out slightly faster than the corresponding (Z)-isomers, but their peaks almost overlapped. On the other hand, HPLC equipped with an ODS column completely separated the two geometric isomers examined and the (Z)-isomers eluted from the column faster than the (E)-isomers without dependence on a functional group. In addition to undergoing direct HPLC analysis without derivatization, the dienyl alcohols were converted into 3,5-dinitrobenzoates and analyzed by LC-ESI-MS operated under the same reversed-phase condition. The two separated geometric isomers were sensitively monitored by negative ions at m/z 211, M, M+1, M+17, and M+31, which were characteristically derived from the benzoates. Based on these results, a pheromone extract of P. l. lepida was examined, and it was confirmed that the female moths exclusively produced the (Z)-isomer of the 7,9-diene. Furthermore, a GC-EAD analysis and a field evaluation with both geometrical isomers indicated that the mating communication of P. l. lepida is predominantly mediated with the (Z)-isomer.

  19. Simultaneous quantification of delta-9-THC, THC-acid A, CBN and CBD in seized drugs using HPLC-DAD.

    PubMed

    Ambach, Lars; Penitschka, Franziska; Broillet, Alain; König, Stefan; Weinmann, Wolfgang; Bernhard, Werner

    2014-10-01

    An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN). Copyright © 2014. Published by Elsevier Ireland Ltd.

  20. Comparison of high-performance liquid chromatography and supercritical fluid chromatography using evaporative light scattering detection for the determination of plasticizers in medical devices.

    PubMed

    Lecoeur, Marie; Decaudin, Bertrand; Guillotin, Yoann; Sautou, Valérie; Vaccher, Claude

    2015-10-23

    Recently, interest in supercritical fluid chromatography (SFC) has increased due to its high throughput and the development of new system improving chromatographic performances. However, most papers dealt with fundamental studies and chiral applications and only few works described validation process of SFC method. Likewise, evaporative light scattering detection (ELSD) has been widely employed in liquid chromatography but only a few recent works presented its quantitative performances hyphenated with SFC apparatus. The present paper discusses about the quantitative performances of SFC-ELSD compared to HPLC-ELSD, for the determination of plasticizers (ATBC, DEHA, DEHT and TOTM) in PVC tubing used as medical devices. After the development of HPLC-ELSD, both methods were evaluated based on the total error approach using accuracy profile. The results show that HPLC-ELSD was more precise than SFC-ELSD but lower limits of quantitation were obtained by SFC. Hence, HPLC was validated in the ± 10% acceptance limits whereas SFC lacks of accuracy to quantify plasticizers. Finally, both methods were used to determine the composition of plasticized-PVC medical devices. Results demonstrated that SFC and HPLC both hyphenated with ELSD provided similar results. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Screening and Analysis of the Marker Components in Ganoderma lucidum by HPLC and HPLC-MSn with the Aid of Chemometrics.

    PubMed

    Wu, Lingfang; Liang, Wenyi; Chen, Wenjing; Li, Shi; Cui, Yaping; Qi, Qi; Zhang, Lanzhen

    2017-04-06

    Ganoderma triterpenes (GTs) are the major secondary metabolites of Ganoderma lucidum , which is a popularly used traditional Chinese medicine for complementary cancer therapy. The present study was to establish a fingerprint evaluation system based on Similarity Analysis (SA), Cluster Analysis (CA) and Principal Component Analysis (PCA) for the identification and quality control of G. lucidum . Fifteen samples from the Chinese provinces of Hainan, Neimeng, Shangdong, Jilin, Anhui, Henan, Yunnan, Guangxi and Fujian were analyzed by HPLC-PAD and HPLC-MS n . Forty-seven compounds were detected by HPLC, of which forty-two compounds were tentatively identified by comparing their retention times and mass spectrometry data with that of reference compounds and reviewing the literature. Ganoderic acid B, 3,7,15-trihydroxy-11,23-dioxolanost-8,16-dien-26-oic acid, lucidenic acid A, ganoderic acid G, and 3,7-oxo-12-acetylganoderic acid DM were deemed to be the marker compounds to distinguish the samples with different quality according to both CA and PCA. This study provides helpful chemical information for further research on the anti-tumor activity and mechanism of action of G. lucidum . The results proved that fingerprints combined with chemometrics are a simple, rapid and effective method for the quality control of G. lucidum .

  2. Methods and applications of HPLC-AMS (WBio 5)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucholz, B A; Clifford, A J; Duecker, S R

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a {sup 14}C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the {sup 14}C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement.more » Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the {sup 14}C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of {sup 14}C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected {sup 14}C activity <0.17 Bq (4.5 pCi) on the HPLC column.« less

  3. Diversity oriented high-throughput screening of 1,3,4-oxadiazole modified chlorophenylureas and halogenobenzamides by HPLC with peptidomimetic calixarene-bonded stationary phases.

    PubMed

    Bazylak, Grzegorz; Malak, Anna; Ali, Imran; Borowiak, Teresa; Dutkiewicz, Grzegorz

    2008-06-01

    Retention profiles in series of the neutral and highly hydrophobic 1,3,4-oxadiazoles containing chlorophenylurea and halogenobenzamide moiety and indicating analgesic activity were determined in the isocratic standard- and narrow-bore HPLC systems employing, respectively, various octadecylsilica and different calixarene bonded stationary phases. When acetonitrile - 2.65 mM phosphoric acid (55 : 45, %, v/v), pH* 3.25, mobile phase was applied retention of these compounds increased with decline of their overall hydrophobicity according to the general preference of more polar compounds by calixarene cavity in time of its non-specific host-guest supramolecular interactions with halogenated substances. The size of calixarene nanocavity and its upper-rim substitution did not change the observed retention order, resolution and selectivity of separation for oxadiazoles. Compared to the retention on the non-end-capped and the highly-end-capped octadecylsilica HPLC column a most improved separation of some regioisomers of halogenated 1,3,4-oxadiazoles were observed on both used calixarene-type HPLC supports. In addition, preliminary data on the self-assembled supramolecular crystal structure of exemplary 1,3,4-oxadiazolchlorophenylurea with cis-elongated conformation was reported and formation of the monovalent inclusion host-guest complexes between 1,3,4-oxadiazoles and each calixarene-type stationary phase was studied with molecular modelling MM+ and AM1 methods. The structural, isomeric and energetic factors leading to the hydrogen bond stabilized inclusion complexes between these species were considered and used for explanation of observed retention sequence and selectivity of 1,3,4-oxadiazoles separation in applied calixarene-based HPLC systems. All these data would be useful in future development of optimized procedures enabling encapsulation of 1,3,4-oxadiazolurea-type drugs with calixarenes.

  4. Development of at-line assay to monitor charge variants of MAbs during production.

    PubMed

    St Amand, M M; Ogunnaike, B A; Robinson, A S

    2014-01-01

    One major challenge currently facing the biopharmaceutical industry is to understand how MAb microheterogeneity affects therapeutic efficacy, potency, immunogenicity, and clearance. MAb micro-heterogeneity can result from post-translational modifications such as sialylation, galactosylation, C-terminal lysine cleavage, glycine amidation, and tryptophan oxidation, each of which can generate MAb charge variants; such heterogeneity can affect pharmacokinetics (PK) considerably. Implementation of appropriate on-line quality control strategies may help to regulate bioprocesses, thus enabling more homogenous material with desired post-translational modifications and PK behavior. However, one major restriction to implementation of quality control strategies is the availability of techniques for obtaining on-line or at-line measurements of these attributes. In this work, we describe the development of an at-line assay to separate MAb charge variants in near real-time, which could ultimately be used to implement on-line quality control strategies for MAb production. The assay consists of a 2D-HPLC method with sequential in-line Protein A and WCX-10 HPLC column steps. To perform the 2D-HPLC assay at-line, the two columns steps were integrated into a single method using a novel system configuration that allowed parallel flow over column 1 or column 2 or sequential flow from column 1 to column 2. A bioreactor system was also developed such that media samples could be removed automatically from bioreactor vessels during production and delivered to the 2D-HPLC for analysis. With this at-line HPLC assay, we have demonstrated that MAb microheterogeneity occurs throughout the cell cycle whether the host cell line is grown under different or the same nominal culture conditions. © 2013 American Institute of Chemical Engineers.

  5. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography

    PubMed Central

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    Objective: In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. Materials and Methods: In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. Results: HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. Conclusion: The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. SUMMARY Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida PMID:26941534

  6. Rapid resolution liquid chromatography-mass spectrometry and high-performance liquid chromatography-fluorescence detection for metabolism and pharmacokinetic studies of ergosta-4,6,8(14),22-tetraen-3-one.

    PubMed

    Zhao, Ying-Yong; Qin, Xiang-Yang; Cheng, Xian-Long; Liu, Xue-Ying; Lin, Rui-Chao; Zhang, Yongmin; Li, Xiao-Ye; Sun, Xiao-Li; Sun, Wen-Ji

    2010-08-24

    Ergosta-4,6,8(14),22-tetraen-3-one (ergone) from many medicinal plants has been demonstrated to possess a variety of pharmacological activities in vivo and in vitro, including cytotoxic, diuretic and immunosuppressive activity. Metabolism and pharmacokinetic studies on rat were conducted for ergone. Rapid resolution liquid chromatography with atmospheric pressure chemical ionization tandem multi-stage mass spectrometry (RRLC-APCI-MS(n)) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD) methods were applied for the identification and quantification of ergone and its metabolite from rat plasma, faeces and urine. A metabolite was identified by RRLC-DAD-APCI-MS(n): 22,23-epoxy-ergosta-4,6,8(14)-triaen-3-one (epoxyergone). The concentrations of the analyte with its metabolites were determined by HPLC-FLD at excitation wavelength of 370 nm and emission wavelength of 485 nm. The samples were deproteinized with methanol after addition of camptothecin as internal standard (IS). The analysis was performed on a Diamonsil C18 column (150 mm x 4.6 mm x 5 microm) with a mobile phase gradient consisting of methanol and water at a flow rate of 1 mL min(-1). The assay was linear over the concentration range of 42-1500, 36-7500 and 42-1500 ng mL(-1) for plasma, faecal homogenate and urine respectively. The absolute recoveries were found to be 97.0+/-1.2%, 98.1+/-0.7% and 96.6+/-1.8% for plasma, faecal homogenate and urine respectively. The intra-day and inter-day relative standard deviations (RSD) were less than 10%. The previous HPLC-MS/MS method is not affordable for most laboratories because of the specialty requirement and high equipment cost. However, the HPLC-FLD method is economic and operating simply for quantitative determination of ergone and its metabolite in rat plasma, faeces and urine. In addition, liquid chromatography coupled with ion trap multi-stage mass spectrometry is becoming a useful technique for ergone metabolite identification. 2010 Elsevier B.V. All rights reserved.

  7. Quantification of 2'-deoxy-2'-β-fluoro-4'-azidocytidine in rat and dog plasma using liquid chromatography-quadrupole time-of-flight and liquid chromatography-triple quadrupole mass spectrometry: Application to bioavailability and pharmacokinetic studies.

    PubMed

    Peng, Youmei; Cheng, Tiefeng; Dong, Lihong; Zhang, Yuhai; Chen, Xiaojing; Jiang, Jinhua; Zhang, Jingmin; Guo, Xiaohe; Guo, Mintong; Chang, Junbiao; Wang, Qingduan

    2014-09-01

    2'-Deoxy-2'-β-fluoro-4'-azidocytidine (FNC) is a novel pyrimidine analog that inhibits not only the replication of the hepatitis B virus (HBV), hepatitis C virus (HCV) and HIV but also the replication of lamivudine-resistant HBV, 4'-azidocytidine or 2'-β-methylcytidine-resistant HCV, and nucleoside reverse-transcriptase inhibitor-resistant HIV variants. The present study was undertaken to evaluate the absolute oral bioavailability of FNC in rats and the pharmacokinetic properties of FNC after intragastric administration of single and multiple doses in rats and dogs. A sensitive high-performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry (HPLC/Q-TOF MS) method and a reliable high-performance liquid chromatography tandem triple quadrupole mass spectrometry (HPLC/QqQ MS/MS) method were established for the determination of FNC in the rat and dog plasmas, respectively. The sample preparation involved a protein-precipitation method with methanol after the addition of lamivudine as an internal standard. FNC was analyzed by LC using a YMC-Pack Pro C18 column (150mm×4.6mm, 3μm) with methanol (containing 0.3% formic acid): 10mM ammonium acetate (containing 0.3% formic acid, pH 2.8) (35:65, v/v) as the mobile phase. Both mass spectrometers were equipped with an electrospray ionization interface in the positive-ion mode. The linear range was from 2.00 to 2000.00ngmL(-1) in rat plasma and 0.50 to 400.00ngmL(-1) in dog plasma. The intraday and interday precision were less than 10.55%, and the accuracy was in the range of -5.86 to 5.13%. The mean recoveries were greater than 82.70% and 82.97% for FNC and IS, respectively. The HPLC/Q-TOF MS and HPLC/QqQ MS/MS methods were both successfully applied in the pharmacokinetic studies of FNC in rats and dogs. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Miniaturised electrically actuated high pressure injection valve for portable capillary liquid chromatography.

    PubMed

    Li, Yan; Pace, Kirsten; Nesterenko, Pavel N; Paull, Brett; Stanley, Roger; Macka, Mirek

    2018-04-01

    A miniaturised high pressure 6-port injection valve has been designed and evaluated for its performance in order to facilitate the development of portable capillary high performance liquid chromatography (HPLC). The electrically actuated valve features a very small size (65 × 19 × 19mm) and light weight (33g), and therefore can be easily integrated in a miniaturised modular capillary LC system suited for portable field analysis. The internal volume of the injection valve was determined as 98 nL. The novel conical shape of the stator and rotor and the spring-loaded rotor performed well up to 32MPa (4641psi), the maximum operating pressure investigated. Suitability for application was demonstrated using a miniaturised capillary LC system applied to the chromatographic separation of a mixture of biogenic amines and common cations. The RSD (relative standard deviation) values of retention times and peak areas of 6 successive runs were 0.5-0.7% and 1.8-2.8% for the separation of biogenic amines, respectively, and 0.1-0.2% and 2.1-3.0% for the separation of cations, respectively. This performance was comparable with bench-top HPLC systems thus demonstrating the applicability of the valve for use in portable and miniaturised capillary HPLC systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Definition and characterization of a "trypsinosome" from specific peptide characteristics by nano-HPLC-MS/MS and in silico analysis of complex protein mixtures.

    PubMed

    Le Bihan, Thierry; Robinson, Mark D; Stewart, Ian I; Figeys, Daniel

    2004-01-01

    Although HPLC-ESI-MS/MS is rapidly becoming an indispensable tool for the analysis of peptides in complex mixtures, the sequence coverage it affords is often quite poor. Low protein expression resulting in peptide signal intensities that fall below the limit of detection of the MS system in combination with differences in peptide ionization efficiency plays a significant role in this. A second important factor stems from differences in physicochemical properties of each peptide and how these properties relate to chromatographic retention and ultimate detection. To identify and understand those properties, we compared data from experimentally identified peptides with data from peptides predicted by in silico digest of all corresponding proteins in the experimental set. Three different complex protein mixtures extracted were used to define a training set to evaluate the amino acid retention coefficients based on linear regression analysis. The retention coefficients were also compared with other previous hydrophobic and retention scale. From this, we have constructed an empirical model that can be readily used to predict peptides that are likely to be observed on our HPLC-ESI-MS/MS system based on their physicochemical properties. Finally, we demonstrated that in silico prediction of peptides and their retention coefficients can be used to generate an inclusion list for a targeted mass spectrometric identification of low abundance proteins in complex protein samples. This approach is based on experimentally derived data to calibrate the method and therefore may theoretically be applied to any HPLC-MS/MS system on which data are being generated.

  10. High performance liquid chromatographic determination of caffeine in decaffeinated coffee, tea, and beverage products.

    PubMed

    Ashoor, S H; Seperich, G J; Monte, W C; Welty, J

    1983-05-01

    A method was developed for determining caffeine in decaffeinated coffee, tea, and beverage products by high performance liquid chromatography (HPLC). The HPLC system consisted of a Bio-Sil ODS-5S C18 column, methanol-water (25 + 75) mobile phase at 1 mL/min, and a UV detector. The method is simple and specific. Caffeine recoveries were 93.8-98.3% and coefficients of variation were 0.90-2.25%.

  11. Design and Prototype of an Automated Column-Switching HPLC System for Radiometabolite Analysis.

    PubMed

    Vasdev, Neil; Collier, Thomas Lee

    2016-08-17

    Column-switching high performance liquid chromatography (HPLC) is extensively used for the critical analysis of radiolabeled ligands and their metabolites in plasma. However, the lack of streamlined apparatus and consequently varying protocols remain as a challenge among positron emission tomography laboratories. We report here the prototype apparatus and implementation of a fully automated and simplified column-switching procedure to allow for the easy and automated determination of radioligands and their metabolites in up to 5 mL of plasma. The system has been used with conventional UV and coincidence radiation detectors, as well as with a single quadrupole mass spectrometer.

  12. Chemical fingerprinting and quantitative constituent analysis of Siwu decoction categorized formulae by UPLC-QTOF/MS/MS and HPLC-DAD

    PubMed Central

    2013-01-01

    Background Siwu decoction categorized formulae (SWDCF) are widely used for treating gynecological diseases. This study aims to elucidate the differences of bioactive constituents in SWDCF by ultra-high performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC - QTOF - MS /MS) and HPLC-DAD. Methods An efficient method based on UPLC - QTOF - MS /MS was developed for identifying the chemical profiles of SWDCF. HPLC-DAD method was used for quantifying seven chemical markers in SWDCF. Results Eighty four components were identified or characterized, including ten organic acids, thirty glycosides (monoterpene or iridoid or phenylpropanoids glycosides), fourteen lactones, eighteen flavonoids, and eleven alkaloids in the complex system. The datasets of tR-m/z pairs, ion intensities and sample codes were processed with supervised orthogonal partial least squared discriminant analysis to compare these decoction samples. After a clear classification was established, OPLS-DA was performed and 16 common components with relative quantity in SWDCF samples were determined. Gallic acid, protocatechuic acid, vanillic acid, caffeic acid, paeoniflorin, ferulic acid, and senkyunolide I were selected as the chemical markers to identify SWDCF by HPLC-DAD. Conclusion The chemical profiles with 84 components in SWDCF, including monoterpene glycosides, acetophenones, galloyl glucoses, even some isomers in the complex system were characterized by UPLC–QTOF–MS/MS. PMID:23453004

  13. [HPLC fingerprint of Calendula officinalis flower].

    PubMed

    Xing, Zhan-Fen; Cheng, Hong-Da; Zhang, Ping-Ping; Gong, Lei; Ma, Li-Ya

    2014-07-01

    To establish an HPLC fingerprint of Calendula officinalis flower for its quality control. Hypersil ODS C18 column (250 mm x 4.6 mm, 5 μm) was used with acetonitrile and water as mobile phase in a gradient mode at the flow rate of 1.0 mL/min. The detection wavelength was 220 nm and the temperature of column was set at 35 degrees C. The similarity was analyzed with the Estimating System of Similarity on the Chinese Medicine Fingerprint Chromatogram. The HPLC fingerprint of Calendula officinalis flower containing eleven peaks was set up. The similarity of Calendula officinalis flower from different habitats was greater than 0.90. This method is easy and reliable, which can be used to judge the habitat and control the quality of Calendula officinalis flower.

  14. HPLC study on the 'history' dependence of gramicidin A conformation in phospholipid model membranes.

    PubMed

    Bañó, M C; Braco, L; Abad, C

    1989-06-19

    A novel HPLC methodology for the study of gramicidin A reconstituted in model membranes has been tested in comparison with circular dichroism data. It is shown that this chromatographic technique not only corroborates most of the recent spectroscopic results but allows one to explain them in terms of mass fractions of different actual conformational species of GA in the phospholipid assemblies. In particular, the dependence of the inserted peptide configuration on the organic solvent and other parameters involved in the 'history' of the sample preparation and handling has been analyzed by HPLC in two phospholipid model systems: small unilamellar vesicles and micelles. Moreover, a slow conformational transition of GA towards a beta 6.3-helical configuration, accelerated by heat incubation, has been also chromatographically visualized and quantitatively interpreted.

  15. Synthesis, liquid chromatographic fractionation and partial characterization of polybrominated dibenzofuran congeners.

    PubMed

    Gallistl, Christoph; Vetter, Walter

    2016-04-15

    Polybrominated dibenzofurans (PBDFs) are a class of highly toxic environmental contaminants which comprises 135 structurally different congeners. While the gas chromatographic separation and analysis of the most polychlorinated dibenzofurans (PCDFs) are well-documented, comparably little data is currently available in the case of PBDFs. In this study dibenzofuran was brominated to give a mixture of ∼40 PBDFs with one to seven bromine atoms. This synthesis mixture was fractionated by both countercurrent chromatography (CCC) with the solvent system n-hexane/toluene/acetonitrile and non-aqueous reversed-phase high performance liquid chromatography (RP-HPLC) with acetonitrile as the mobile phase. All together 80 consecutive CCC fractions and 40 HPLC fractions were taken and analyzed for PBDFs by gas chromatography coupled to mass spectrometry (GC/MS). CCC and RP-HPLC offered orthogonal separation of the PBDF mixture. As a consequence, selected CCC fractions were further fractionated by RP-HPLC. In this way, eight PBDFs could be isolated and the structures of twelve PBDFs were elucidated by proton magnetic resonance spectroscopy ((1)H NMR). Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Stability of amoxicillin-clavulanate in BACTEC medium determined by high-performance liquid chromatography and bioassay.

    PubMed Central

    Moore, T D; Horton, R; Utrup, L J; Miller, L A; Poupard, J A

    1996-01-01

    The stabilities of amoxicillin (16 micrograms/ml) and clavulanate (8 micrograms/ml), alone and in combination in BACTEC medium (Middlebrook 7H12B medium), were determined by high-performance liquid chromatography (HPLC) and bioassay. By HPLC, the half-life of amoxicillin (trihydrate and sodium) in combination with clavulanate in nonradiolabelled 7H12B medium was 6.7 days, whereas the half-life of clavulanate in combination with amoxicillin was 2.0 days. By bioassay, the half-lives of amoxicillin trihydrate and clavulanate in radiolabelled 7H12B medium were comparable (7 and 2 days, respectively) to those determined by HPLC. When clavulanate was tested alone, the half-life was determined to be 1.88 days by HPLC and 1.87 days by bioassay. The relatively short half-life of clavulanate can be adjusted by a procedure of "topping up," or adding one-half the concentration of clavulanate every second day, in order to allow accurate amoxicillin-clavulanate MIC testing with the BACTEC mycobacterial susceptibility system. PMID:8727931

  17. Preparative separation of grape skin polyphenols by high-speed counter-current chromatography.

    PubMed

    Luo, Lanxin; Cui, Yan; Zhang, Shuting; Li, Lingxi; Li, Yuanyuan; Zhou, Peiyu; Sun, Baoshan

    2016-12-01

    To develop an efficient method for large preparation of various individual polyphenols from white grape skins (Fernão Pires; Vitis vinifera) by preparative high-speed counter-current chromatography (HSCCC) and preparative-HPLC, an optimized preparative HSCCC condition with two-phase solvent system composed of Hex-EtOAc-H2O (1:50:50, v/v) was used to separate grape skin polyphenols into various fractions. Both the tail-head and head-tail elution modes were used with a flow rate of 3.0ml/min and a rotary speed of 950rpm. Afterwards, a preparative-HPLC separation was applied to isolate individual polyphenols in each of the fractions from HSCCC. Total of 7 fractions (Fraction A to G) were obtained from grape skin extract by HSCCC. After preparative-HPLC isolation, fifteen individual compounds were obtained, most of which presented high yields and purity (all over 90%). The HSCCC method followed with preparative-HPLC appeared to be convenient and economical, constituting an efficient strategy for the isolation of grape skin polyphenols. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Isolation of campesteryl ferulate and epi-campesteryl ferulate, two components of γ-oryzanol from rice bran.

    PubMed

    Bao, Yuhua; Yanase, Emiko; Nakatsuka, Shin-ichi

    2013-01-01

    Campesteryl ferulate (3a, 24R/α) and epi-campesteryl ferulate (3b, 24S/β), components of rice bran γ-oryzanol, were isolated by the preparative recycle HPLC system using a combination of ODS silica and cholester packed columns at over 99% purity. Their purities and structures of 3a and 3b thus obtained were confirmed by HPLC analysis and physical data (1H- and 13C-NMR, MS spectra, and X-ray crystallography).

  19. Analysis of small droplets with a new detector for liquid chromatography based on laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Janzen, Christoph; Fleige, Rüdiger; Noll, Reinhard; Schwenke, Heinrich; Lahmann, Wilhelm; Knoth, Joachim; Beaven, Peter; Jantzen, Eckard; Oest, Andreas; Koke, Peter

    2005-08-01

    The miniaturization of analytical techniques is a general trend in speciation analytics. We have developed a new analytical technique combining high pressure liquid chromatography (HPLC) with laser-induced breakdown spectroscopy (LIBS). This enables a molecule-specific separation followed by an element-specific analysis of smallest amounts of complex samples. The liquid flow coming from a HPLC pump is transformed into a continuous stream of small droplets (diameter 50-100 μm, volume 65-500 pl) using a piezoelectric pulsed nozzle. After the detection of single droplets with a droplet detector, a Q-switched Nd:YAG Laser is triggered to emit a synchronized laser pulse that irradiates a single droplet. The droplets are evaporated and transformed to the plasma state. The spectrum emitted from the plasma is collected by a spherical mirror and directed through the entrance slit of a Paschen-Runge spectrometer equipped with channel photomultipliers. The spectrometer detects 31 elements simultaneously covering a spectral range from 120 to 589 nm. Purging the measurement chamber with argon enables the detection of vacuum-UV lines. Since the sample is transferred to the plasma state without dilution, very low flow rates in the sub-μl/min range can be realised.

  20. Development of an Ion-Pairing Reagent and HPLC-UV Method for the Detection and Quantification of Six Water-Soluble Vitamins in Animal Feed.

    PubMed

    Kim, Ho Jin

    2016-01-01

    A novel and simple method for detecting six water-soluble vitamins in animal feed using high performance liquid chromatography equipped with a photodiode array detector (HPLC/PDA) and ion-pairing reagent was developed. The chromatographic peaks of the six water-soluble vitamins were successfully identified by comparing their retention times and UV spectra with reference standards. The mobile phase was composed of buffers A (5 mM PICB-6 in 0.1% CH3COOH) and B (5 mM PICB-6 in 65% methanol). All peaks were detected using a wavelength of 270 nm. Method validation was performed in terms of linearity, sensitivity, selectivity, accuracy, and precision. The limits of detection (LODs) for the instrument employed in these experiments ranged from 25 to 197 μg/kg, and the limits of quantification (LOQs) ranged from 84 to 658 μg/kg. Average recoveries of the six water-soluble vitamins ranged from 82.3% to 98.9%. Method replication resulted in intraday and interday peak area variation of <5.6%. The developed method was specific and reliable and is therefore suitable for the routine analysis of water-soluble vitamins in animal feed.

  1. Global Profiling of Reactive Oxygen and Nitrogen Species in Biological Systems

    PubMed Central

    Zielonka, Jacek; Zielonka, Monika; Sikora, Adam; Adamus, Jan; Joseph, Joy; Hardy, Micael; Ouari, Olivier; Dranka, Brian P.; Kalyanaraman, Balaraman

    2012-01-01

    Herein we describe a high-throughput fluorescence and HPLC-based methodology for global profiling of reactive oxygen and nitrogen species (ROS/RNS) in biological systems. The combined use of HPLC and fluorescence detection is key to successful implementation and validation of this methodology. Included here are methods to specifically detect and quantitate the products formed from interaction between the ROS/RNS species and the fluorogenic probes, as follows: superoxide using hydroethidine, peroxynitrite using boronate-based probes, nitric oxide-derived nitrosating species with 4,5-diaminofluorescein, and hydrogen peroxide and other oxidants using 10-acetyl-3,7-dihydroxyphenoxazine (Amplex® Red) with and without horseradish peroxidase, respectively. In this study, we demonstrate real-time monitoring of ROS/RNS in activated macrophages using high-throughput fluorescence and HPLC methods. This global profiling approach, simultaneous detection of multiple ROS/RNS products of fluorescent probes, developed in this study will be useful in unraveling the complex role of ROS/RNS in redox regulation, cell signaling, and cellular oxidative processes and in high-throughput screening of anti-inflammatory antioxidants. PMID:22139901

  2. Preparative isolation and purification of seven main antioxidants from Eucommia ulmoides Oliv. (Du-zhong) leaves using HSCCC guided by DPPH-HPLC experiment.

    PubMed

    Dai, Xingping; Huang, Qiong; Zhou, Boting; Gong, Zhicheng; Liu, Zhaoqian; Shi, Shuyun

    2013-08-15

    Seven antioxidants were purified from Eucommia ulmoides Oliv. leaves using HSCCC guided by DPPH-HPLC experiment. HSCCC was successfully used to separate target antioxidants by three runs with different solvent systems after D101 column chromatography fractionation. Ethyl acetate-n-butanol-water (1:2:3, v/v/v) was selected as the optimum solvent system to purify geniposidic acid. Ethyl acetate-ethanol-water (4:1:5, v/v/v) was used to isolate caffeic acid, chlorogenic acid and ferulic acid. While three flavonoids, quercetin-3-O-sambubioside, rutin and isoquercitrin were purified by petroleum ether-ethyl acetate-methanol-water (1:5:1:5, v/v/v/v). The structures were identified by MS and NMR. Antioxidant activities were assessed, and compounds 2-7 showed strong antioxidant activities. This is the first report about separation of antioxidants from E. ulmoides leaves by HSCCC. The results indicated that the combinative methods using DPPH-HPLC and HSCCC could be widely applied for screening and isolation of antioxidants from complex extracts. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. [HPLC Fingerprint of QingGuangAn and Determination of the Main Components].

    PubMed

    Wang, Min; Shen, Bing-bing; Luo, Juan; Chen, Yang; Yang, Yu-pei; Chen, Sheng-huang

    2015-10-01

    To establish an HPLC fingerprint of ethanol extract of QingGuangAn, and to determine the contents of paeoniflorin and calycosin-7-glucosid. HPLC analysis was performed on an Agilent 1260 Infinity LC system and carried out at 35 degrees C on a column of GRACE Alltima C18 (250 mm x 4.6 mm, 5 μm). A binary gradient elution system was composed of acetonitrile (phase A) and water solution (phase B). Detection was performed at the wavelength of 254 nm, the mobile flow rate was 0.8 mL/min. A matrix including 20 variations (characteristic peaks area) and 10 samples was constructed for similarity evaluation. The results showed that the collected samples had a good similarity. A specificity fingerprint was produced and 20 characteristic peaks were designated. The content of paeoniflorin and calycosin-7-glucosid was 0.368 and 0.049 mg/g, respectively. It is a reliable, available and quick method for quality control of QingGuangAn,which provides some reference for the comparison of different extracting methods of QingGuangAn and the differences of pharmacodynamic.

  4. Fluorescent HPLC for the detection of specific protein oxidation carbonyls - α-aminoadipic and γ-glutamic semialdehydes - in meat systems.

    PubMed

    Utrera, Mariana; Morcuende, David; Rodríguez-Carpena, Javier-Germán; Estévez, Mario

    2011-12-01

    Precise methodologies for the routine analysis of particular protein carbonyls are required in order to progress in this topic of increasing interest. The present paper originally describes the application of an improved method for the detection of α-aminoadipic and γ-glutamic semialdehydes in a meat system by using a derivatization procedure with p-amino-benzoic acid (ABA) followed by fluorescent high-performance liquid chromatography (HPLC). The method development comprises i) the description of a simple HPLC program which allows the efficient separation of the ABA and the key standard compounds and ii) the optimization of the procedure for the preparation of a meat sample in order to maximize the fluorescent signal for both protein carbonyls. Furthermore, the suitability of this method is evaluated by applying the technique to porcine burger patties. The present procedure enables an accurate and relatively fast analysis of both semialdehydes in meat samples in which they could play an interesting role as reliable indicators of protein oxidation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Microwave-assisted extraction with water for fast extraction and simultaneous RP-HPLC determination of phenolic acids in radix Salviae Miltiorrhizae.

    PubMed

    Fang, Xinsheng; Wang, Jianhua; Zhou, Hongying; Jiang, Xingkai; Zhu, Lixiang; Gao, Xin

    2009-07-01

    An optimized microwave-assisted extraction method using water (MAE-W) as the extractant and an efficient HPLC analysis method were first developed for the fast extraction and simultaneous determination of D(+)-(3,4-dihydroxyphenyl) lactic acid (Dla), salvianolic acid B (SaB), and lithospermic acid (La) in radix Salviae Miltiorrhizae. The key parameters of MAE-W were optimized. It was found that the degradation of SaB was inhibited when using the optimized MAE-W and the stable content of Dla, La, and SaB in danshen was obtained. Furthermore, compared to the conventional extraction methods, the proposed MAE-W is a more rapid method with higher yield and lower solvent consumption with a reproducibility (RSD <6%). In addition, using water as extractant is safe and helpful for environment protection, which could be referred to as green extraction. The separation and quantitative determination of the three compounds was carried out by a developed reverse-phase high-performance liquid chromatographic (RP-HPLC) method with UV detection. Highly efficient separation was obtained using gradient solvent system. The optimized HPLC analysis method was validated to have specificity, linearity, precision, and accuracy. The results indicated that MAE-W followed by HPLC-UV determination is an appropriate alternative to previously proposed method for quality control of radix Salviae Miltiorrhizae.

  6. Identification and anti-oxidant capacity determination of phenolics and their glycosides in elderflower by on-line HPLC-CUPRAC method.

    PubMed

    Çelik, S Esin; Özyürek, Mustafa; Güçlü, Kubilay; Çapanoğlu, Esra; Apak, Reşat

    2014-01-01

    Development and application of an on-line cupric reducing anti-oxidant capacity (CUPRAC) assay coupled with HPLC for separation and on-line determination of phenolic anti-oxidants in elderflower (Sambucus nigra L.) extracts for their anti-oxidant capacity are significant for evaluating health-beneficial effects. Moreover, this work aimed to assay certain flavonoid glycosides of elderflower that could not be identified/quantified by other similar on-line HPLC methods (i.e. 2,2-diphenyl-1-picrylhdrazyl and 2, 2'-azino-bis-3-ethylbenzothiazoline-6-sulphonic acid). To identify anti-oxidant constituents in elderflower by HPLC and to evaluate their individual anti-oxidant capacities by on-line HPLC-CUPRAC assay with a post-column derivatisation system. The separation and UV detection of polyphenols were performed on a C18 -column using gradient elution with two different mobile phase solutions, that is acetonitrile and 1% glacial acetic acid, with detection at 340 nm. The HPLC-separated anti-oxidant polyphenols in column effluent react with copper(II)-neocuproine in a reaction-coil to reduce the latter to copper(I)-neocuproine (Cu(I)-Nc) chelate having maximum absorption at 450 nm. The detection limits of tested compounds at 450 nm after post-column derivatisation were compared with those of at 340 nm UV-detection without derivatisation. LOD values (µg/mL) of quercetin and its glycosides at 450 nm were lower than those of UV detection at 340 nm. This method was applied successfully to elderflower extract. The flavonol glycosides of quercetin and kaempferol bound to several sugar components (glucose, rhamnose, galactose and rutinose) were identified in the sample. The on-line HPLC-CUPRAC method was advantageous over on-line ABTS and DPPH methods for measuring the flavonoid glycosides of elderflower. Copyright © 2014 John Wiley & Sons, Ltd.

  7. [Determination of glycyrrhizinic acid in biotransformation system by reversed-phase high performance liquid chromatography].

    PubMed

    Li, Hui; Lu, Dingqiang; Liu, Weimin

    2004-05-01

    A method for determining glycyrrhizinic acid in the biotransformation system by reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The HPLC conditions were as follows: Hypersil C18 column (4.6 mm i.d. x 250 mm, 5 microm) with a mixture of methanol-water-acetic acid (70:30:1, v/v) as the mobile phase; flow rate at 1.0 mL/min; and UV detection at 254 nm. The linear range of glycyrrhizinic acid was 0.2-20 microg. The recoveries were 98%-103% with relative standard deviations between 0.16% and 1.58% (n = 3). The method is simple, rapid and accurate for determining glycyrrhizinic acid.

  8. Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC–ESI-MS–MS

    DOE PAGES

    Kertesz, Vilmos; Calligaris, David; Feldman, Daniel R.; ...

    2015-06-18

    Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland.more » AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.« less

  9. Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC–ESI-MS–MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Calligaris, David; Feldman, Daniel R.

    Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland.more » AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.« less

  10. Analysis of D3-,4-,5-phosphorylated phosphoinositides using HPLC.

    PubMed

    Munnik, Teun

    2013-01-01

    Detection of polyphosphoinositides (PPIs) is difficult due to their low chemical abundancy. This problem is further complicated by the fact that PPIs are present as various, distinct isomers, which are difficult, if not impossible, to separate by conventional thin layer chromatography (TLC) systems. PPIs in plants include PtdIns3P, PtdIns4P, PtdIns5P, PtdIns(3,5)P 2, and PtdIns(4,5)P 2. Here, a protocol is described analyzing plant PPIs using (32)P-orthophosphorus pre-labeled material. After extraction, lipids are deacylated and the resulting glycerophosphoinositol polyphosphates (GroPInsPs) separated by HPLC using a strong anion-exchange column and a shallow salt gradient. Alternatively, PPIs are first separated by TLC, the lipids reisolated, deacylated, and the GroPInsPs then separated by HPLC.

  11. Identification of phenolic compounds in red wine extract samples and zebrafish embryos by HPLC-ESI-LTQ-Orbitrap-MS.

    PubMed

    Vallverdú-Queralt, Anna; Boix, Nuria; Piqué, Ester; Gómez-Catalan, Jesús; Medina-Remon, Alexander; Sasot, Gemma; Mercader-Martí, Mercè; Llobet, Juan M; Lamuela-Raventos, Rosa M

    2015-08-15

    The zebrafish embryo is a highly interesting biological model with applications in different scientific fields, such as biomedicine, pharmacology and toxicology. In this study, we used liquid chromatography/electrospray ionisation-linear ion trap quadrupole-Orbitrap-mass spectrometry (HPLC/ESI-LTQ-Orbitrap-MS) to identify the polyphenol compounds in a red wine extract and zebrafish embryos. Phenolic compounds and anthocyanin metabolites were determined in zebrafish embryos previously exposed to the red wine extract. Compounds were identified by injection in a high-resolution system (LTQ-Orbitrap) using accurate mass measurements in MS, MS(2) and MS(3) modes. To our knowledge, this research constitutes the first comprehensive identification of phenolic compounds in zebrafish by HPLC coupled to high-resolution mass spectrometry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Qualitative and quantitative analysis of the diuretic component ergone in Polyporus umbellatus by HPLC with fluorescence detection and HPLC-APCI-MS/MS.

    PubMed

    Zhao, Ying-Yong; Zhao, Ye; Zhang, Yong-Min; Lin, Rui-Chao; Sun, Wen-Ji

    2009-06-01

    Polyporus umbellatus is a widely used anti-aldosteronic diuretic in Traditional Chinese medicine (TCM). A new, sensitive and selective high-performance liquid chromatography-fluorescence detector (HPLC-FLD) and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS/MS) method for quantitative and qualitative determination of ergosta-4,6,8(14),22-tetraen-3-one(ergone), which is the main diuretic component, was provided for quality control of P. umbellatus crude drug. The ergone in the ethanolic extract of P. umbellatus was unambiguously characterized by HPLC-APCI, and further confirmed by comparing with a standard compound. The trace ergone was detected by the sensitive and selective HPLC-FLD. Linearity (r2 > 0.9998) and recoveries of low, medium and high concentration (100.5%, 100.2% and 100.4%) were consistent with the experimental criteria. The limit of detection (LOD) of ergone was around 0.2 microg/mL. Our results indicated that the content of ergone in P. umbellatus varied significantly from habitat to habitat with contents ranging from 2.13 +/- 0.02 to 59.17 +/- 0.05 microg/g. Comparison among HPLC-FLD and HPLC-UV or HPLC-APCI-MS/MS demonstrated that the HPLC-FLD and HPLC-APCI-MS/MS methods gave similar quantitative results for the selected herb samples, the HPLC-UV methods gave lower quantitative results than HPLC-FLD and HPLC-APCI-MS/MS methods. The established new HPLC-FLD method has the advantages of being rapid, simple, selective and sensitive, and could be used for the routine analysis of P. umbellatus crude drug.

  13. A simple HPLC-DAD method for simultaneous detection of two organophosphates, profenofos and fenthion, and validation by soil microcosm experiment.

    PubMed

    Mahajan, Rishi; Chatterjee, Subhankar

    2018-05-05

    Indiscriminate use of two broad spectrum pesticides, profenofos and fenthion, in agricultural system, often results in their accumulation in a non-target niche and leaching into water bodies. The present study, therefore, aims at developing a simple and rapid HPLC method that allows simultaneous extraction and detection of these two pesticides, especially in run-off water. Extraction of the two pesticides from spiked water samples using dichloromethane resulted in recovery ranging between 80 and 90%. An HPLC run of 20 min under optimized chromatographic parameters (mobile phase: methanol (75%) and water (25%); flow rate of 0.8 ml min -1 ; diode array detector at wavelength 210 nm) resulted in a significant difference in retention times of two pesticides (4.593 min) which allows a window of opportunity to study any possible intermediates/transformants of the parent compounds while evaluating run-off waters from agricultural fields. The HPLC method developed allowed simultaneous detection of profenofos and fenthion with a single injection into the HPLC system with 0.0328 mg l -1 (32.83 ng ml -1 ) being the limit of detection (LOD) and 0.0995 mg l -1 (99.5 ng ml -1 ) as the limit of quantification (LOQ) for fenthion; for profenofos, LOD and LOQ were 0.104 mg l -1 (104.50 ng ml -1 ) and 0.316 mg l -1 (316.65 ng ml -1 ), respectively. The findings were further validated using the soil microcosm experiment that allowed simultaneous detection and quantification of profenofos and fenthion. The findings indicate towards the practical significance of the methodology developed as the soil microcosm experiment closely mimics the agricultural run-off water under natural environmental conditions.

  14. Aqueous Reversed-Phase HPLC/FT-IR Using Diffuse Reflectance Detections

    NASA Astrophysics Data System (ADS)

    Kalasinsky, Victor F.; Pai, T. H.; Kenton, R. C.; Kalasinsky, Kathryn S.

    1989-12-01

    Solvent-elimination HPLC/FT-IR has become a viable combination of two important techniques, and we have been developing a system which is adaptable to both normal and reversed-phase liquid chromatography. The interface involves the deposition of HPLC eluites onto a KCI-laden train with subsequent analysis via diffuse reflectance spectroscopy, and with minor modifications, the system can be used with microbore and analytical columns. With aqueous solvents, the water is converted to methanol and acetone in a post-column reaction with 2,2-dimethoxypropane before the eluites are deposited. A number of different samples have been used to demonstrate the interface and its flexibility. Steroids, analgesics, and other pharmaceutical preparations have been separated with reverse-phase solvents and identified by their infrared spectra. For some of the compounds studied, different infrared spectra of a given compound have been found to exhibit intensity variations, which arise from different crystalline states. The differences can be concentration dependent and may be useful in obtaining semi-quantitative information from the infrared spectra. Applications involving both gradient elution and isocratic separations have been successful. The former provides the same advantages for HPLC/FT-IR as one finds in conventional HPLC. More recent work has been applied to the use of buffers such as those frequently used in bioanalytical separations. In trying to simplify the post-column reaction with water, we have immobilized dehydration reagents onto silica particles and packed these materials into a column which is inserted in-line after the analytical column. Of the reagents utilized to date, 3,3-dimethoxypropyltrimethoxysilane has been found to perform most efficiently. It has advantages over the simpler reagents because it can be regenerated in the reaction column. Results and the efficiency of the dehydration process and its relation to the type of reagent and its coverage will be discussed.

  15. High-performance liquid chromatographic characterization of some medical plant extracts used in cosmetic formulas.

    PubMed

    Schulz, H; Albroscheit, G

    1988-06-17

    Rapid and reliable methods are presented for the characterization of biologically active and/or characteristic constituents in aqueous extracts of Hamamelis virginiana, Matricaria chamomilla, Achillea millefolium, Thymus vulgaris, Althaea officinalis and Cinchonia spp. Prior to high-performance liquid chromatographic (HPLC) separation a clean-up step was performed using a solid-phase extraction system. The purified extracts were analysed by HPLC coupled with a diode-array detector and a fluorescence detector. In some instances, previously unreported components of the aqueous plant extracts were found.

  16. An Efficient Method for the Preparative Isolation and Purification of Flavonoids from Leaves of Crataegus pinnatifida by HSCCC and Pre-HPLC.

    PubMed

    Wen, Lei; Lin, Yunliang; Lv, Ruimin; Yan, Huijiao; Yu, Jinqian; Zhao, Hengqiang; Wang, Xiao; Wang, Daijie

    2017-05-09

    In this work, flavonoid fraction from the leaves of Crataegus pinnatifida was separated into its seven main constituents using a combination of HSCCC coupled with pre-HPLC. In the first step, the total flavonoid extract was subjected to HSCCC with a two-solvent system of chloroform/methanol/water/ n -butanol (4:3:2:1.5, v/v ), yielding four pure compounds, namely (-)-epicatechin ( 1 ), quercetin-3- O -(2,6-di-α-l-rhamnopyranosyl)-β-d-galactopyranoside ( 2 ), 4''- O -glucosylvitexin ( 3 ) and 2''- O -rhamnosylvitexin ( 4 ) as well as a mixture of three further flavonoids. An extrusion mode was used to rapidly separate quercetin-3- O -(2,6-di-α-l-rhamnopyranosyl)-β-d-galactopyranoside with a big K D -value. In the second step, the mixture that resulted from HSCCC was separated by pre-HPLC, resulting in three pure compounds including: vitexin ( 5 ), hyperoside ( 6 ) and isoquercitrin ( 7 ). The purities of the isolated compounds were established to be over 98%, as determined by HPLC. The structures of these seven flavonoids were elucidated by ESI-MS and NMR spectroscopic analyses.

  17. An Investigation Into HPLC Data Quality Problems

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B.; VanHeukelem, Laurie

    2011-01-01

    This report summarizes the analyses and results produced by a five-member investigative team of Government, university, and industry experts, established by NASA HQ. The team examined data quality problems associated with high performance liquid chromatography (HPLC) analyses of pigment concentrations in seawater samples produced by the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS). This report shows CHORS did not validate the methods used before placing them into service to analyze field samples for NASA principal investigators (PIs), even though the HPLC literature contained easily accessible method validation procedures, and the importance of implementing them, more than a decade ago. In addition, there were so many sources of significant variance in the CHORS methodologies, that the HPLC system rarely operated within performance criteria capable of producing the requisite data quality. It is the recommendation of the investigative team to a) not correct the data, b) make all the data that was temporarily sequestered available for scientific use, and c) label the affected data with an appropriate warning, e.g., "These data are not validated and should not be used as the sole basis for a scientific result, conclusion, or hypothesis--independent corroborating evidence is required."

  18. [Relationship between HPLC fingerprint chromatogram and inhibitory effect on respiratory burst of rat PMN of leaves of crataegus].

    PubMed

    Liu, Rong-hua; Yu, Bo-yang; Chen, Lan-ying; Liu, Ji-hua; Shao, Feng; Ma, Zhi-lin; Yang, Ming

    2008-08-01

    To study the relationship between HPLC fingerprint chromatogram and inhibitory effect on respiratory burst of rat PMN of leaves of crataegus L. HPLC fingerprint peaks of different species of hawthorn leaves were isolated and used for the effective experiment on the respiratory burst of rat PMN. The mathematic models of the relationship between the area and the effect of fingerprint peaks were established. According to the mathematic models, the HPLC fingerprint were change into bioactive fingerprint (include effective fingerprint and potency fingerprint) with the helps of mathematics, chemometrics, computer program simulation and etc. The chromatogram-effect relationship of leaves of crataegus. on respiratory burst of rat PMN was established. According to this relationship, the activities of fourteen samples of leaves of crataegus. were forecasted. It was positive correlation between the expected value and the practical value. And the correlation coefficients was 0.968 (P < 0.01). An all-around evaluative system, which includes not only chemical identification but also effective evaluation for traditional Chinese medicine was established. It will provide a new idea for study on fingerprint chromatogram of traditional Chinese medicine.

  19. Identification of a Panax ginseng fruit fingerprint by HPLC-ESI-MS.

    PubMed

    Zhao, H F; Xu, F F; Guo, Y T; Mi, H

    2016-03-11

    Over many years, parts of Panax ginseng (root and rhizome) have been identified and applied for medical purposes as traditional Chinese herbal medicine. Recently, research has indicated that ginseng fruit also contains similar compounds and is as rich as the other parts of the ginseng. This discovery may dramatically improve the efficient of outputs derived from ginseng products. Here, a new technique combining high-performance liquid chromatography (HPLC) with electrospray ionization tandem mass spectrometry (ESI-MS) was employed to identify the fingerprint of P. ginseng fruit. Using HPLC, compounds that are important for medical purposes were extracted and purified. Combined with ESI-MS, the characteristic peaks (nine common peaks) of those compounds were identified, and the accuracy was confirmed by analysis using the Chromatographic Fingerprint Similarity Evaluation System (2004A edition). Overall, 15 batches of ginseng fruit had a similarity of more than 0.80, 13 batches of samples had a similarity between 0.97 and 0.99, and two batches had a similarity less than 0.90. The test solution and mobile phase selection was discussed. The HPLC-ESI-MS method can produce repeatable and reliable results and can be applied in the quality control of P. ginseng fruit.

  20. [Study on HPLC fingerprint of flavonoids from Houttuynia cordata by comparing with fingerprint reference].

    PubMed

    Zhang, Ting-Ting; Wu, Yi; Hang, Tai-Jun

    2009-05-01

    To establish a stable and repeatable HPLC fingerprint standard and evaluate the flavonoids from Houttuynia cordata qualitatively and quantitatively. HPLC separation was performed on a C18 column with methanol-0.1% phosphoric acid mixed solution as mobile phase in gradient elution mode. The fingerprint reference was determined as one of the most typical chromatograms and used to be compared with other samples through Cosine and Relative Euclid Distance methods, thus the chromatographic fingerprints of flavonoids from Houttuynia cordata were evaluated by constitutes and contents, respectively. Fourteen mutual peaks were fixed in the HPLC fingerprint of flavonoids from Houttaynia cordata. It showed good results in validation tests in which the quercitrin's peak was set as the reference peak to calculate relative retention time and area of other peaks in the chromatograms, and the RSD were less than 0.2% and 5.0%, respectively. The linear ranges for quercitrin was 1.07-83.4 microg/mL (r=0.9999) and the average recovery was 100.3%. The method shows good repeatability, ruggedness and reliability. Comparing with the established reference fingerprint, the evaluation system including Cosine and Relative Euclid Distance methods lays dependable foundation for controlling the quality of Houttuynia cordata.

  1. Ultrafast UPLC-ESI-MS and HPLC with monolithic column for determination of principal flavor compounds in vanilla pods.

    PubMed

    Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P

    2009-10-01

    In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.

  2. A nonradioactive high-performance liquid chromatographic microassay for uridine 5'-monophosphate synthase, orotate phosphoribosyltransferase, and orotidine 5'-monophosphate decarboxylase.

    PubMed

    Krungkrai, J; Wutipraditkul, N; Prapunwattana, P; Krungkrai, S R; Rochanakij, S

    2001-12-15

    A novel nonradioactive, microassay method has been developed to determine simultaneously the two enzymatic activities of orotate phosphoribosyltransferase (OPRTase) and orotidine 5'-monophosphate decarboxylase (ODCase), either as a bifunctional protein (uridine 5'-monophosphate synthase, UMPS) or as separate enzymes. Substrates (orotate for OPRTase or orotidine 5'-monophosphate for ODCase) and a product (UMP) of the enzymatic assay were separated by high-performance liquid chromatography (HPLC) using a reversed-phase column and an ion-pairing system; the amount of UMP was quantified by dual-wavelength uv detection at 260 and 278 nm. This HPLC assay can easily detect picomole levels of UMP in enzymatic reactions using low specific activity UMPS of mammalian cell extracts, which is difficult to do with the other nonradioactive assays that have been described. The HPLC assay is suitable for use in protein purification and for kinetic study of these enzymes. (c)2001 Elsevier Science.

  3. Screening and analysis of bioactive compounds with biofingerprinting chromatogram analysis of traditional Chinese medicines targeting DNA by microdialysis/HPLC.

    PubMed

    Su, Xingye; Kong, Liang; Li, Xin; Chen, Xueguo; Guo, Ming; Zou, Hanfa

    2005-05-27

    Biofingerprinting chromatogram analysis, which is defined as the comparison of fingerprinting chromatograms of the extract of traditional Chinese medicines (TCMs) before and after the interaction with biological systems (DNA, protein, cell, etc.), was proposed for screening and analysis of the multiple bioactive compounds in TCMs. A method of microdialysis sampling combined with high performance liquid chromatography (HPLC) was applied to the study of DNA-binding property for the extracts of TCMs. Seven compounds were found to bind to calf thymus DNA (ct-DNA) from the TCMs of Coptis chinensis Franch (Coptis), but only three ones from Phellodendron amurense Rupr. (Phellodendron) and none from Sophoraflavescens Ait. (Sophora) to bind to ct-DNA, respectively. Three of them were identified as berberine, palmatine and jatrorrhizine and their association constants (K) to ct-DNA were determined by microdialysis/HPLC. Competitive binding behaviors of them to ct-DNA were also investigated.

  4. Application of an efficient strategy based on liquid-liquid extraction, high-speed counter-current chromatography, and preparative HPLC for the rapid enrichment, separation, and purification of four anthraquinones from Rheum tanguticum.

    PubMed

    Chen, Tao; Liu, Yongling; Zou, Denglang; Chen, Chen; You, Jinmao; Zhou, Guoying; Sun, Jing; Li, Yulin

    2014-01-01

    This study presents an efficient strategy based on liquid-liquid extraction, high-speed counter-current chromatography, and preparative HPLC for the rapid enrichment, separation, and purification of four anthraquinones from Rheum tanguticum. A new solvent system composed of petroleum ether/ethyl acetate/water (4:2:1, v/v/v) was developed for the liquid-liquid extraction of the crude extract from R. tanguticum. As a result, emodin, aloe-emodin, physcion, and chrysophanol were greatly enriched in the organic layer. In addition, an efficient method was successfully established to separate and purify the above anthraquinones by high-speed counter-current chromatography and preparative HPLC. This study supplies a new alternative method for the rapid enrichment, separation, and purification of emodin, aloe-emodin, physcione, and chrysophanol. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A Microfluidics-HPLC/Differential Mobility Spectrometer Macromolecular Detection System for Human and Robotic Missions

    NASA Technical Reports Server (NTRS)

    Coy, S. L.; Killeen, K.; Han, J.; Eiceman, G. A.; Kanik, I.; Kidd, R. D.

    2011-01-01

    Our goal is to develop a unique, miniaturized, solute analyzer based on microfluidics technology. The analyzer consists of an integrated microfluidics High Performance Liquid Chromatographic chip / Differential Mobility Spectrometer (?HPLCchip/ DMS) detection system

  6. Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases

    PubMed Central

    Kalmár, É; Kormányos, B.; Szakonyi, G.; Dombi, G.

    2014-01-01

    Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine. PMID:24799736

  7. Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.

    PubMed

    Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M

    2016-11-01

    Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.

  8. Assay of amoxicillin and clavulanic acid, the components of Augmentin, in biological fluids with high-performance liquid chromatography.

    PubMed

    Foulstone, M; Reading, C

    1982-11-01

    Augmentin is a new antibacterial formulation comprised of amoxicillin and the beta-lactamase inhibitor clavulanic acid. In the present paper, the use of high-performance liquid chromatography (HPLC) to provide a rapid assay of the components of Augmentin in body fluids is described. Clavulanic acid was assayed by reacting the sample with imidazole, which readily produces a derivative absorbing at 311 nm. This derivative chromatographs on reverse-phase HPLC columns clear of interfering components in both human serum and urine. Concentrations of clavulanic acid as low as 0.1 microgram/ml were readily detectable in human serum with this procedure. There was no interference from amoxicillin, amoxicillin penicilloic acid, or the acid and alkali degradation products of clavulanic acid when this assay system was used. Amoxicillin in body fluids was assayed directly by HPLC without derivatization. The same chromatographic conditions were employed for the assay of amoxicillin and the clavulanic acid derivative, simplifying the methodology. Amoxicillin, however, was determined of the antibiotic per ml. An alkali blanking procedure for amoxicillin and clavulanic acid is also described which allows the detection of any underlying peaks which may cochromatograph. The use of ultrafiltration to remove protein from serum samples before HPLC was successfully applied to the assay of clavulanic acid and amoxicillin. Ultrafiltration is not an essential procedure for these assays, but it prolongs column life and reduces interference in the amoxicillin assay. Results obtained by HPLC were compared with those obtained by using microbiological assays.

  9. A novel HPLC fluorescence method for the quantification of methylphenidate in human plasma

    PubMed Central

    Zhu, Hao-Jie; Wang, Jun-Sheng; Patrick, Kennerly S.; Donovan, Jennifer L.; DeVane, C. Lindsay; Markowitz, John S.

    2007-01-01

    A number of analytical methods have been established to quantify methylphenidate (MPH). However, to date no HPLC methods are applicable to human pharmacokinetic studies without the use of mass spectrometry (MS) detection. We developed a sensitive and reliable HPLC-fluorescence method for the determination of MPH in human plasma using 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) as the derivatizing agent. An established GC-MS method was adopted in this study as a comparator assay. MPH was derivatized DIB-Cl, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (λex: 330 nm, λem: 460 nm). The lower limit of determination was found to be 1 ng/mL. A linear calibration curve was obtained over the concentrations ranging from 1 to 80 ng/mL (r=0.998). The relative standard deviations of intra-day and inter-day variations were ≤ 9.10 % and ≤ 7.58 %, respectively. The accuracy ranged between 92.59 % and 103.06 %. The method was successfully applied to the pharmacokinetic study of a subject who received a single oral dose (0.3 mg/kg) of immediate-release MPH and yielded consistent results with that of the GC-MS method. This method is the first HPLC assay with non-MS detection providing sufficient reliability and sensitivity for both pre-clinical and clinical studies of MPH. PMID:17804308

  10. Characterization of Compounds in Psoralea corylifolia Using High-Performance Liquid Chromatography Diode Array Detection, Time-of-Flight Mass Spectrometry and Quadrupole Ion Trap Mass Spectrometry.

    PubMed

    Tan, Guangguo; Yang, Tiehong; Miao, Huayan; Chen, Hao; Chai, Yifeng; Wu, Hong

    2015-10-01

    High-performance liquid chromatography with diode array detection (HPLC-DAD), time-of-flight mass spectrometry (HPLC-TOFMS) and quadrupole ion trap mass spectrometry (HPLC-QITMS) were used for separation and identification of multi-components in Psoralea corylifolia. Benefiting from combining the accurate mass measurement of HPLC-TOFMS to generate elemental compositions, the complementary multilevel structural information provided by HPLC-QITMS and the characteristic UV spectra obtained from HPLC-DAD, 24 components in P. corylifolia were identified. The five groups of isomers were differentiated based on the fragmentation behaviors in QITMS and UV spectra. It can be concluded that an effective method based on the combination of HPLC-DAD, HPLC-TOFMS and HPLC-QITMS for identification of chemical components in P. corylifolia was established. The results provide essential data for further pharmacological and clinical studies of P. corylifolia and facilitate the rapid quality control of the crude drug. © Crown copyright 2015.

  11. 14 CFR 23.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... environmental conditions, including the indirect effects of lightning strikes. (2) Any equipment and system does... Equipment General § 23.1309 Equipment, systems, and installations. The requirements of this section, except... requirements of part 23, to any equipment or system as installed in the airplane. This section is a regulation...

  12. 14 CFR 23.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... environmental conditions, including the indirect effects of lightning strikes. (2) Any equipment and system does... Equipment General § 23.1309 Equipment, systems, and installations. The requirements of this section, except... requirements of part 23, to any equipment or system as installed in the airplane. This section is a regulation...

  13. Cluster analysis of historical and modern hard red spring wheat cultivars based on parentage and HPLC analysis of gluten forming proteins

    USDA-ARS?s Scientific Manuscript database

    In this study, 30 hard red spring (HRS) wheat cultivars released between 1910 and 2013 were analyzed to determine how they cluster in terms of parentage and protein data, analyzed by reverse-phase HPLC (RP-HPLC) of gliadins, and size-exclusion HPLC (SE-HPLC) of unreduced proteins. Dwarfing genes in...

  14. Fully automated SPE-based synthesis and purification of 2-[18F]fluoroethyl-choline for human use.

    PubMed

    Schmaljohann, Jörn; Schirrmacher, Esther; Wängler, Björn; Wängler, Carmen; Schirrmacher, Ralf; Guhlke, Stefan

    2011-02-01

    2-[(18)F]Fluoroethyl-choline ([(18)F]FECH) is a promising tracer for the detection of prostate cancer as well as brain tumors with positron emission tomography (PET). [(18)F]FECH is actively transported into mammalian cells, becomes phosphorylated by choline kinase and gets incorporated into the cell membrane after being metabolized to phosphatidylcholine. So far, its synthesis is a two-step procedure involving at least one HPLC purification step. To allow a wider dissemination of this tracer, finding a purification method avoiding HPLC is highly desirable and would result in easier accessibility and more reliable production of [(18)F]FECH. [(18)F]FECH was synthesized by reaction of 2-bromo-1-[(18)F]fluoroethane ([(18)F]BFE) with dimethylaminoethanol (DMAE) in DMSO. We applied a novel and very reliable work-up procedure for the synthesis of [(18)F]BFE. Based on a combination of three different solid-phase cartridges, the purification of [(18)F]BFE from its precursor 2-bromoethyl-4-nitrobenzenesulfonate (BENos) could be achieved without using HPLC. Following the subsequent reaction of the purified [(18)F]BFE with DMAE, the final product [(18)F]FECH was obtained as a sterile solution by passing the crude reaction mixture through a combination of two CM plus cartridges and a sterile filter. The fully automated synthesis was performed using as well a Raytest SynChrom module (Raytest, Germany) or a Scintomics HotboxIII module (Scintomics, Germany). The radiotracer [(18)F]FECH can be synthesized in reliable radiochemical yields (RCY) of 37±5% (Synchrom module) and 33±5% (Hotbox III unit) in less than 1 h using these two fully automated commercially available synthesis units without HPLC involvement for purification. Detailed quality control of the final injectable [(18)F]FECH solution proved the high radiochemical purity and the absence of Kryptofix2.2.2, DMAE and DMSO used in the course of synthesis. Sterility and bacterial endotoxin testing following standard procedures verified that the described production method for [(18)F]FECH is suitable for human applications. The routine production of [(18)F]FECH with sufficient RCYs was established by reliable and fast solid-phase extraction purifications of both the secondary labeling precursor [(18)F]BFE and the final product [(18)F]FECH, avoiding complex and sensitive HPLC equipment. The purity of the product was >95%, rendering the tracer suitable for human application. The newly developed purification procedure for [(18)F]BFE significantly reduces the complexity of the automated synthesis unit, hence reducing the cost for routine production in a clinical setup and allowing easy transfer to different synthesis modules. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Detection and quantification of new psychoactive substances (NPSs) within the evolved "legal high" product, NRG-2, using high performance liquid chromatography-amperometric detection (HPLC-AD).

    PubMed

    Zuway, Khaled Y; Smith, Jamie P; Foster, Christopher W; Kapur, Nikil; Banks, Craig E; Sutcliffe, Oliver B

    2015-09-21

    The global increase in the production and abuse of cathinone-derived New Psychoactive Substances (NPSs) has developed the requirement for rapid, selective and sensitive protocols for their separation and detection. Electrochemical sensing of these compounds has been demonstrated to be an effective method for the in-field detection of these substances, either in their pure form or in the presence of common adulterants, however, the technique is limited in its ability to discriminate between structurally related cathinone-derivatives (for example: (±)-4′-methylmethcathinone (4-MMC, 2a) and (±)-4′-methyl-N-ethylmethcathinone (4-MEC, 2b) when they are both present in a mixture. In this paper we demonstrate, for the first time, the combination of HPLC-UV with amperometric detection (HPLC-AD) for the qualitative and quantitative analysis of 4-MMC and 4-MEC using either a commercially available impinging jet (LC-FC-A) or custom-made iCell channel (LC-FC-B) flow-cell system incorporating embedded graphite screen-printed macroelectrodes. The protocol offers a cost-effective, reproducible and reliable sensor platform for the simultaneous HPLC-UV and amperometric detection of the target analytes. The two systems have similar limits of detection, in terms of amperometric detection [LC-FC-A: 14.66 μg mL(-1) (2a) and 9.35 μg mL(-1) (2b); LC-FC-B: 57.92 μg mL(-1) (2a) and 26.91 μg mL(-1) (2b)], to the previously reported oxidative electrochemical protocol [39.8 μg mL(-1) (2a) and 84.2 μg mL(-1) (2b)], for two synthetic cathinones, prevalent on the recreational drugs market. Though not as sensitive as standard HPLC-UV detection, both flow cells show a good agreement, between the quantitative electroanalytical data, thereby making them suitable for the detection and quantification of 4-MMC and 4-MEC, either in their pure form or within complex mixtures. Additionally, the simultaneous HPLC-UV and amperometric detection protocol detailed herein shows a marked improvement and advantage over previously reported electroanalytical methods, which were either unable to selectively discriminate between structurally related synthetic cathinones (e.g. 4-MMC and 4-MEC) or utilised harmful and restrictive materials in their design.

  16. An application of second-order UV-derivative spectrophotometry for study of solvolysis of a novel fluocinolone acetonide ester

    NASA Astrophysics Data System (ADS)

    Markovic, Bojan; Vladimirov, Sote; Cudina, Olivera; Savic, Vladimir; Karljikovic-Rajic, Katarina

    2010-02-01

    A novel topical corticosteroid FA-21-PhP, 2-phenoxypropionate ester of fluocinolone acetonide, has been synthesized in order to investigate the possibility of decreasing systemic side effects. In this study model system for in vitro solvolytic reaction of FA-21-PhP has been analyzed in ethanol/water (90:10, v/v) with excess of sodium hydrogen carbonate. The selected conditions have been used as in vitro model for activation of corticosteroid C-21 ester prodrug. The second-order derivative spectrophotometric method (DS) using zero-crossing technique was developed for monitoring ternary mixture of solvolysis. Fluocinolone acetonide (FA) as a solvolyte was determined in the mixture in the concentration range 0.062-0.312 mM using amplitude 2D 274.96. Experimentally determined LOD value was 0.0295 mM. The accuracy of proposed DS method was confirmed with HPLC referent method. Peak area of parent ester FA-21-PhP was used for solvolysis monitoring to ensure the initial stage of changes. Linear relationship in HPLC assay for parent ester was obtained in the concentration range 0.054-0.54 mM, with experimentally determined LOD value of 0.0041 mM. Investigated solvolytic reaction in the presence of excess of NaHCO 3 proceeded via a pseudo-first-order kinetic with significant correlation coefficients 0.9891 and 0.9997 for DS and HPLC, respectively. The values of solvolysis rate constant calculated according to DS and HPLC methods are in good accordance 0.038 and 0.043 h -1, respectively.

  17. Simultaneous determination of the quantity and isotopic signature of dissolved organic matter from soil water using high-performance liquid chromatography/isotope ratio mass spectrometry.

    PubMed

    Scheibe, Andrea; Krantz, Lars; Gleixner, Gerd

    2012-01-30

    We assessed the accuracy and utility of a modified high-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS) system for measuring the amount and stable carbon isotope signature of dissolved organic matter (DOM) <1 µm. Using a range of standard compounds as well as soil solutions sampled in the field, we compared the results of the HPLC/IRMS analysis with those from other methods for determining carbon and (13)C content. The conversion efficiency of the in-line wet oxidation of the HPLC/IRMS averaged 99.3% for a range of standard compounds. The agreement between HPLC/IRMS and other methods in the amount and isotopic signature of both standard compounds and soil water samples was excellent. For DOM concentrations below 10 mg C L(-1) (250 ng C total) pre-concentration or large volume injections are recommended in order to prevent background interferences. We were able to detect large differences in the (13)C signatures of soil solution DOM sampled in 10 cm depth of plots with either C3 or C4 vegetation and in two different parent materials. These measurements also demonstrated changes in the (13)C signature that demonstrate rapid loss of plant-derived C with depth. Overall the modified HLPC/IRMS system has the advantages of rapid sample preparation, small required sample volume and high sample throughput, while showing comparable performance with other methods for measuring the amount and isotopic signature of DOM. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Analytical Quality by Design Approach in RP-HPLC Method Development for the Assay of Etofenamate in Dosage Forms

    PubMed Central

    Peraman, R.; Bhadraya, K.; Reddy, Y. Padmanabha; Reddy, C. Surayaprakash; Lokesh, T.

    2015-01-01

    By considering the current regulatory requirement for an analytical method development, a reversed phase high performance liquid chromatographic method for routine analysis of etofenamate in dosage form has been optimized using analytical quality by design approach. Unlike routine approach, the present study was initiated with understanding of quality target product profile, analytical target profile and risk assessment for method variables that affect the method response. A liquid chromatography system equipped with a C18 column (250×4.6 mm, 5 μ), a binary pump and photodiode array detector were used in this work. The experiments were conducted based on plan by central composite design, which could save time, reagents and other resources. Sigma Tech software was used to plan and analyses the experimental observations and obtain quadratic process model. The process model was used for predictive solution for retention time. The predicted data from contour diagram for retention time were verified actually and it satisfied with actual experimental data. The optimized method was achieved at 1.2 ml/min flow rate of using mobile phase composition of methanol and 0.2% triethylamine in water at 85:15, % v/v, pH adjusted to 6.5. The method was validated and verified for targeted method performances, robustness and system suitability during method transfer. PMID:26997704

  19. Simultaneous determination of 13 phytohormones in oilseed rape tissues by liquid chromatography-electrospray tandem mass spectrometry and the evaluation of the matrix effect.

    PubMed

    Fan, Sufang; Wang, Xiupin; Li, Peiwu; Zhang, Qi; Zhang, Wen

    2011-03-01

    In the experiment, a high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry with selected reaction monitoring was used to simultaneously determine various classes of phytohormones, including indole-3-acetic acid, α-naphthaleneacetic acid, 2-chlorobenzoic acid, 4-chlorobenzoic acid, indole-3-butyric acid, gibberellic acid, 2,4-dichlorophenoxyacetic acid, 2-naphthoxyacetic acid, abscisic acid, 2,3,5-triiodobenzoic acid, uniconazole, paclobutrazol and 2,4-epibassinolide in rape tissues. The analyses were separated by an HPLC equipped with a reversed-phase column using a binary solvent system composed of methanol and water, both containing 0.1% of formic acid. The matrix effect was also considered and determined. The technology was applied to analyze rape tissues, including roots, stems, leaves, flowers, immature pods and rape seeds. The rape tissues were subjected to ultrasound-assisted extraction and purified by dispersive solid-phase extraction, and then transferred into the liquid chromatography system. The detection limit for each plant hormone was defined by the ratio of signal/background noise (S/N) of 3. The results showed perfect linearity (R(2) values of 0.9987-1.0000) and reproducibility of elution times (relative standard deviations, RSDs,<1%) and peak areas (RSDs,<7%) for all target compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Comprehensive two-dimensional liquid chromatography separations of pharmaceutical samples using dual Fused-Core columns in the 2nd dimension.

    PubMed

    Alexander, Anthony J; Ma, Lianjia

    2009-02-27

    This paper focuses on the application of RPLC x RPLC to pharmaceutical analysis and addresses the specific problem of separating co-eluting impurities/degradation products that maybe "hidden" within the peak envelope of the active pharmaceutical ingredient (API) and thus may escape detection by conventional methods. A comprehensive two-dimensional liquid chromatograph (LC x LC) was constructed from commercially available HPLC equipment. This system utilizes two independently configurable 2nd dimension binary pumping systems to deliver independent flow rates, gradient profiles and mobile phase compositions to dual Fused-Core secondary columns. Very fast gradient separations (30s total cycle time) were achieved at ambient temperature without excessive backpressure and without compromising optimal 1st dimension sampling rates. The operation of the interface is demonstrated for the analysis of a 1mg/ml standard mixture containing 0.05% of a minor component. The practicality of using RPLC x RPLC for the analysis of actual co-eluting pharmaceutical degradation products, by exploiting pH-induced changes in selectivity, is also demonstrated using a three component mixture. This mixture (an API, an oxidation product of the API at 1.0%, w/w, and a photo degradant of the API at 0.5%, w/w) was used to assess the stability indicating nature of an established LC method for analysis of the API.

  1. Study and development of reversed-phase HPLC systems for the determination of 2-imidazolines in the presence of preservatives in pharmaceutical preparations.

    PubMed

    Antoniou, Constantinos G; Markopoulou, Catherine K; Kouskoura, Maria G; Koundourellis, John E

    2011-01-01

    Different HPLC chromatographic systems were investigated on a C18 ACE 5 pm, 150 x 4.6 mm id column for the determination of tymazoline, tramazoline, and antazoline, with either naphazoline or xylometazoline, in commercial preparations. For the development and optimization of the systems, a Response Surface Method (r=0.925-0.980) was used to illustrate the changes in k as a function of pH values and different salt concentrations. The simultaneous separation of 2-imidazolines was accomplished at 40 degrees C with 0.01 M ammonium acetate-methanol (50+50, v/v, pH 6.0) mobile phase at a flow rate of 1.2 mL/min. In order to deal with the usual coexistence of 2-imidazolines with benzethonium and benzalkonium chloride preservatives, it was necessary to use another chromatographic system, 0.01 M ammonium acetate-methanol (50+50, v/v) mobile phase on a cyano ACE 5 pm, 150 x 4.6 mm id column. As part of a more thorough theoretical investigation, a partial least-squares (PLS) technique was used for modeling the RP-HPLC retention data. The model was based on molecular structure descriptors of the analytes' X variables and on their retention time (Log K) Y. The goodness of fit was estimated by the PLS correlation coefficient (r2) and root mean square error of estimation values, which were 0.994 and 0.0479, respectively.

  2. An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

    DOE PAGES

    Van Berkel, Gary J.; Weiskittel, Taylor M.; Kertesz, Vilmos

    2014-11-07

    Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparatemore » height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.« less

  3. An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J.; Weiskittel, Taylor M.; Kertesz, Vilmos

    Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparatemore » height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.« less

  4. An efficient HPLC method for the analysis of isomeric purity of technetium-99m-exametazime and identity confirmation using LC-MS.

    PubMed

    Vanderghinste, D; Van Eeckhoudt, M; Terwinghe, C; Mortelmans, L; Bormans, G M; Verbruggen, A M; Vanbilloen, H P

    2003-08-08

    99mTc-exametazime (99mTc-d,l-HMPAO, 99mTc-d,l-hexamethylpropyleneamine oxime) is a neutral rather unstable complex of short-lived 99mTc (t(1/2)=6 h) with the d,l-isomer (mixture of D,D- and L,L-isomers) of a bis-amine bis-oxime tetraligand. It is widely used for measurement of regional cerebral perfusion in nuclear medicine. The meso-isomer (D,L-form) should not be present in a preparation as it is not retained in brain and thus does not provide clinically useful information. Meso-HMPAO is removed from the ligand during the synthesis procedure by repeated recrystallization, but can still be present as impurity in d,l-isomer. Due to the lack of a suitable chromatographic method for analysis of the isomeric purity of 99mTc-exametazime preparations, United States Pharmacopoeia 25 (USP 25) prescribes a biological test in rats for quality control purpose. In this study, we developed a suitable high-performance liquid chromatography (HPLC) method which allows to demonstrate the relative amounts of d,l- and meso-isomer in 99mTc-exametazime and so obviates the need for a biodistribution test in animals as part of the quality control. Due to the low concentrations in which 99mTc-d,l-HMPAO is obtained (typically 2-6 ng/ml), confirmation of the identity of 99mTc-d,l-HMPAO in the monograph of the European Pharmacopoeia is now performed only indirectly by TLC and assessment of its retention time on RP-HPLC. To investigate the potential of radio-LC-MS for assessment of the identity of 99mTc-exametazime, 99mTc-d,l-HMPAO and 99mTc-meso-HMPAO prepared using a Tc-rich eluate were analyzed using a radio-LC-MS system equipped with a time-of-flight mass spectrometer with electrospray ionization. The main peak in the radiometric channel coincided with the molecular ion mass of 99mTc-d,l-HMPAO in the mass spectrometer channel and the measured accurate mass differed only by 0.26 ppm from the theoretical mass. The identity of 99mTc-meso-HMPAO was also confirmed. Thus, radio-LC-MS allowed to obtain strong evidence for the structure of 99mTc-d,l-HMPAO and 99mTc-meso-HMPAO at nanomolar concentration. It is concluded that radio-LC-MS can become a sensitive aid in quality control of "no carrier added" radiopharmaceutical preparations.

  5. Sesamin and sesamolin as unexpected contaminants in various cold-pressed plant oils: NP-HPLC/FLD/DAD and RP-UPLC-ESI/MS(n) study.

    PubMed

    Górnaś, Paweł; Siger, Aleksander; Pugajeva, Iveta; Segliņa, Dalija

    2014-04-01

    Thirteen cold-pressed oils (Japanese quince seed, black caraway, flaxseed, rapeseed, hemp, peanut, sunflower, pumpkin, hazelnut, poppy, walnut, almond and sesame oil) manufactured by the same company over a 2-year period (2011-12) were assessed for lipophilic compounds. The presence of sesamin and sesamolin, two characteristic lignans of sesame oil, were detected in all tested plant oils. Both lignans were identified by NP-HPLC/FLD/DAD and confirmed by a RP-UPLC-ESI/MS(n) method. The lowest amount of sesamin and sesamolin was found for Japanese quince seed oil (0.10 and 0.27 mg/100 g), and the highest, excluding sesame oil, for almond oil (36.21 and 105.42 mg/100 g, respectively). The highly significant correlation between sesamolin and sesamin concentrations was found in all samples tested (r = 0.9999; p < 0.00001). These results indicate contamination of cold-pressed oils from the same source. This investigation highlights the fact that increasing the range of products manufactured by the same company can contribute to a lesser regard for the quality of the final product. Moreover, less attention paid to the quality of final product can be related to the health risks of consumers especially sensitive to allergens. Therefore, proper cleaning of processing equipment is needed to prevent cross-contact of cold-pressed oils.

  6. Individual Phosphatidylcholine Species Analysis by RP-HPLC-ELSD for Determination of Polyenylphosphatidylcholine in Lecithins.

    PubMed

    Lee, Wei-Ju; Weng, Shun-Hsiang; Su, Nan-Wei

    2015-04-22

    Polyenylphosphatidylcholine (PPC), a subgroup of the bioactive agents in phosphatidylcholine (PC), has been indicated to possess liver-protective effects. This study aimed to investigate a promising and feasible method to determine PC molecular species with a reverse phase (RP) high-performance liquid chromatograph (HPLC) equipped with an evaporative light scattering detector (ELSD). Chromatography was achieved using a C30 column and an isocratic mobile phase consisting of acetonitrile/methanol/triethylamine (40/58/2, v/v/v) at a flow rate of 1 mL/min, and ELSD detection was performed using 80 °C for the drift tube and an air flow rate of 1.8 L/min. To identify individual peaks on the chromatogram, MALDI-TOF-MS was employed for initial detection, and then the results were used to investigate the relationship between the retention time and fatty acyl chains of each PC molecule. A linear correlation was observed between the retention time and theoretical carbon number (TCN) of individual PC species. The compositions of PC molecular species in soybean and sunflower lecithins were similar to each other, and the major PC molecular species were 1,2-dilinoleoyl-sn-glycero-3-phosphocholine (LLPC), 1-oleoyl-2-linoleoyl-sn-glycero-3-phosphocholine (OLPC), and 1-palmitoyl-2-linoleoyl-sn-glycero-3-phosphocholine (PLPC). The contents of LLPC in soybean PC and sunflower PC were 40.6% and 64.3%, respectively.

  7. A high-pressure liquid chromatographic method for the determination of N-acetyl-p-aminophenol (acetaminophen) in serum or plasma using a direct injection technique.

    PubMed

    Manno, B R; Manno, J E; Dempsey, C A; Wood, M A

    1981-01-01

    N-Acetyl-p-aminophenol (acetaminophen) is becoming more prevalent as an intoxicant in accidental or intentional overdose, therefore, a direct injection ultra-micro high-pressure liquid chromatographic (HPLC) method has been developed for its quantitation. The HPLC analysis was performed using a Model 110 Solvent Metering Pump equipped with a Model 110-19 Pressure Filter (Altex Scientific, Berkeley, CA), a Model 7120 Rheodyne Injector (Rheodyne, Berkeley, CA) or a Model U6K Injector (Waters Associates, Milford, MA) a Model 440 Absorbance Detector (Water's Associates), and a Model 3380A Recorder Integrator (Hewlett Packard, Avondale, PA). A commercially prepared muBonapak C18 Column (Water's Associates) was used. Acetaminophen was eluted with a mixture of 0.01 mol/L aqueous sodium acetate, pH 4.0: acetonitrile (93:7) and the absorbance detector was operated wih a 254 nm filter. The method, which requires only 2 microL of serum or plasma for analysis, offers several distinct advantages to the analyst. No pre- or post-column extraction or other manipulation of the specimen is required to obtain a quantitative result. Rapid processing of the specimen is possible because both acetaminophen and the internal standard are eluted in less than 10 minutes. The small sample (2 microL) is ideal for use with pediatric patients.

  8. High-performance liquid chromatography as a technique to determine protein adsorption onto hydrophilic/hydrophobic surfaces.

    PubMed

    Huang, Tongtong; Anselme, Karine; Sarrailh, Segolene; Ponche, Arnaud

    2016-01-30

    The purpose of this study is to evaluate the potential of simple high performance liquid chromatography (HPLC) setup for quantification of adsorbed proteins on various type of plane substrates with limited area (<3 cm(2)). Protein quantification was investigated with a liquid chromatography chain equipped with a size exclusion column or a reversed-phase column. By evaluating the validation of the method according to guidelines of the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH), all the results obtained by HPLC were reliable. By simple adsorption test at the contact of hydrophilic (glass) and hydrophobic (polydimethylsiloxane: PDMS) surfaces, kinetics of adsorption were determined and amounts of adsorbed bovine serum albumin, myoglobin and lysozyme were obtained: as expected for each protein, the amount adsorbed at the plateau on glass (between 0.15 μg/cm(2) and 0.4 μg/cm(2)) is lower than for hydrophobic PDMS surfaces (between 0.45 μg/cm(2) and 0.8 μg/cm(2)). These results were consistent with bicinchoninic acid protein determination. According to ICH guidelines, both Reversed Phase and Size Exclusion HPLC can be validated for quantification of adsorbed protein. However, we consider the size exclusion approach more interesting in this field because additional informations can be obtained for aggregative proteins. Indeed, monomer, dimer and oligomer of bovine serum albumin (BSA) were observed in the chromatogram. On increasing the temperature, we found a decrease of peak intensity of bovine serum albumin as well as the fraction of dimer and oligomer after contact with PDMS and glass surface. As the surface can act as a denaturation parameter, these informations can have a huge impact on the elucidation of the interfacial behavior of protein and in particular for aggregation processes in pharmaceutical applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Efficient procedure for isolating methylated catechins from green tea and effective simultaneous analysis of ten catechins, three purine alkaloids, and gallic acid in tea by high-performance liquid chromatography with diode array detection.

    PubMed

    Hu, Bing; Wang, Lin; Zhou, Bei; Zhang, Xin; Sun, Yi; Ye, Hong; Zhao, Liyan; Hu, Qiuhui; Wang, Guoxiang; Zeng, Xiaoxiong

    2009-04-10

    Monomers of (-)-epigallocatechin (EGC), (-)-epigallocatechin gallate (EGCG), (-)-epicatechin (EC), (-)-epicatechin gallate (ECG), (-)-epigallocatechin 3-O-(3-O-methyl) gallate (EGCG3''Me) and (-)-3-O-methyl epicatechin gallate (ECG3'Me) (purity, >97%) were successfully prepared from extract of green tea by two-time separation with Toyopearl HW-40S column chromatography eluted by 80% ethanol. In addition, monomers of (-)-catechin (C), (-)-gallocatechin (GC), (-)-gallocatechin gallate (GCG), and (-)-catechin gallate (CG) (purity, >98%) were prepared from EC, EGC, EGCG, and ECG by heat-epimerization and semi-preparative HPLC chromatography. With the prepared catechin standards, an effective and simultaneous HPLC method for the analysis of gallic acid, tea catechins, and purine alkaloids in tea was developed in the present study. Using an ODS-100Z C(18) reversed-phase column, fourteen compounds were rapidly separated within 15min by a linear gradient elution of formic acid solution (pH 2.5) and methanol. A 2.5-7-fold reduction in HPLC analysis time was obtained from existing analytical methods (40-105min) for gallic acid, tea catechins including O-methylated catechins and epimers of epicatechins, as well as purine alkaloids. Detection limits were generally on the order of 0.1-1.0ng for most components at the applied wavelength of 280nm. Method replication generally resulted in intraday and interday peak area variation of <6% for most tested components in green, Oolong, black, and pu-erh teas. Recovery rates were generally within the range of 92-106% with RSDs less than 4.39%. Therefore, advancement has been readily achievable with commonly used chromatography equipments in the present study, which will facilitate the analytical, clinical, and other studies of tea catechins.

  10. 33 CFR 105.250 - Security systems and equipment maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... systems must be regularly tested in accordance with the manufacturers' recommendations; noted deficiencies... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Security systems and equipment... systems and equipment maintenance. (a) Security systems and equipment must be in good working order and...

  11. Industrial application of green chromatography - II. Separation and analysis of preservatives in skincare products using subcritical water chromatography.

    PubMed

    Yang, Y; Kapalavavi, B; Gujjar, L; Hadrous, S; Marple, R; Gamsky, C

    2012-10-01

    Several high-temperature liquid chromatography (HTLC) and subcritical water chromatography (SBWC) methods have been successfully developed in this study for separation and analysis of preservatives contained in Olay skincare creams. Efficient separation and quantitative analysis of preservatives have been achieved on four commercially available ZirChrom and Waters XBridge columns at temperatures ranging from 100 to 200°C. The quantification results obtained by both HTLC and SBWC methods developed for preservatives analysis are accurate and reproducible. A large number of replicate HTLC and SBWC runs also indicate no significant system building-up or interference for skincare cream analysis. Compared with traditional HPLC separation carried out at ambient temperature, the HTLC methods can save up to 90% methanol required in the HPLC mobile phase. However, the SBWC methods developed in this project completely eliminated the use of toxic organic solvents required in the HPLC mobile phase, thus saving a significant amount of money and making the environment greener. Although both homemade and commercial systems can accomplish SBWC separations, the SBWC methods using the commercial system for preservative analysis are recommended for industrial applications because they can be directly applied in industrial plant settings. © 2012 The Authors ICS © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  12. Diagnostic Accuracy of Global Pharma Health Fund Minilab™ in Assessing Pharmacopoeial Quality of Antimicrobials.

    PubMed

    Pan, Hui; Ba-Thein, William

    2018-01-01

    Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.

  13. 42 CFR 493.1252 - Standard: Test systems, equipment, instruments, reagents, materials, and supplies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Test systems, equipment, instruments... REQUIREMENTS Quality System for Nonwaived Testing Analytic Systems § 493.1252 Standard: Test systems, equipment...) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in...

  14. 78 FR 38093 - Seventh Meeting: RTCA Special Committee 226, Audio Systems and Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-25

    ... Committee 226, Audio Systems and Equipment AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION: Meeting Notice of RTCA Special Committee 226, Audio Systems and Equipment. SUMMARY... 226, Audio Systems and Equipment [[Page 38094

  15. Cholesterol concentrations in lipoprotein fractions separated by anion-exchange-high-performance liquid chromatography in healthy dogs and dogs with hypercholesterolemia.

    PubMed

    Oda, Hitomi; Mori, Akihiro; Hirowatari, Yuji; Takoura, Toshie; Manita, Daisuke; Takahashi, Tomoya; Shono, Saori; Onozawa, Eri; Mizutani, Hisashi; Miki, Yohei; Itabashi, Yukiko; Sako, Toshinori

    2017-10-01

    Anion-exchange (AEX)-high-performance liquid chromatography (HPLC) for measurement of cholesterol can be used to separate serum lipoproteins (high-density lipoprotein (HDL); low-density lipoprotein (LDL); intermediate-density lipoprotein (IDL); very-low-density lipoprotein (VLDL)) in humans. However, AEX-HPLC has not been applied in veterinary practice. We had three objectives: (i) the validation of AEX-HPLC methods including the correlation of serum cholesterol concentration in lipoprotein fraction measured by AEX-HPLC and gel permeation-HPLC (GP-HPLC) in healthy dogs and those with hypercholesterolemia was investigated; (ii) the reference intervals of lipoprotein fractions measured by AEX-HPLC from healthy dogs (n=40) was established; (iii) lipoprotein fractions from the serum of healthy dogs (n=12) and dogs with hypercholesterolemia (n=23) were compared. Analytic reproducibility and precision of AEX-HPLC were acceptable. Positive correlation between serum concentrations of total cholesterol (Total-Chol), HDL cholesterol (HDL-Chol), LDL cholesterol (LDL-Chol)+IDL cholesterol (IDL-Chol), and VLDL cholesterol (VLDL-Chol) was noted for AEX-HPLC and GP-HPLC in healthy dogs and dogs with hypercholesterolemia. Reference intervals measured by AEX-HPLC for serum concentrations of Total-Chol, HDL-Chol, and LDL-Chol were determined to be 2.97-9.32, 2.79-6.57, 0.16-3.28mmol/L (2.5-97.5% interval), respectively. Furthermore, there was significant difference in lipoprotein profiles between healthy and dogs with hypercholesterolemia. These results suggest that AEX-HPLC can be used to evaluate lipoprotein profiles in dogs and could be a new useful indicator of hyperlipidemia in dogs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. [Development and application of reference materials containing mixed degradation products of amoxicillin and ampicillin].

    PubMed

    Li, Wei; Zhang, Wei-Qing; Li, Xiang; Hu, Chang-Qin

    2014-09-01

    Reference materials containing mixed degradation products of amoxicillin and ampicillin were developed after optimization of preparation processes. The target impurities were obtained by controlled stress testing, and each major component was identified with HPLC-MS and compared with single traceable reference standard each. The developed reference materials were applied to system suitability test for verifying HPLC system performed in accordance with set forth in China Pharmacopeia and identification of major impurities in samples based on retention and spectra information, which have advantages over the methods put forth in foreign pharmacopoeias. The development and application of the reference materials offer an effective way for rapid identification of impurities in chromatograms, and provide references for analyzing source of impurities and evaluation of drug quality.

  17. High-protein-low-carbohydrate diet: deleterious metabolic and cardiovascular effects depend on age.

    PubMed

    Bedarida, Tatiana; Baron, Stephanie; Vessieres, Emilie; Vibert, Francoise; Ayer, Audrey; Marchiol-Fournigault, Carmen; Henrion, Daniel; Paul, Jean-Louis; Noble, Florence; Golmard, Jean-Louis; Beaudeux, Jean-Louis; Cottart, Charles-Henry; Nivet-Antoine, Valerie

    2014-09-01

    High-protein-low-carbohydrate (HP-LC) diets have become widespread. Yet their deleterious consequences, especially on glucose metabolism and arteries, have already been underlined. Our previous study (2) has already shown glucose intolerance with major arterial dysfunction in very old mice subjected to an HP-LC diet. The hypothesis of this work was that this diet had an age-dependent deleterious metabolic and cardiovascular outcome. Two groups of mice, young and adult (3 and 6 mo old), were subjected for 12 wk to a standard or to an HP-LC diet. Glucose and lipid metabolism was studied. The cardiovascular system was explored from the functional stage with Doppler-echography to the molecular stage (arterial reactivity, mRNA, immunohistochemistry). Young mice did not exhibit any significant metabolic modification, whereas adult mice presented marked glucose intolerance associated with an increase in resistin and triglyceride levels. These metabolic disturbances were responsible for cardiovascular damages only in adult mice, with decreased aortic distensibility and left ventricle dysfunction. These seemed to be the consequence of arterial dysfunctions. Mesenteric arteries were the worst affected with a major oxidative stress, whereas aorta function seemed to be maintained with an appreciable role of cyclooxygenase-2 to preserve endothelial function. This study highlights for the first time the age-dependent deleterious effects of an HP-LC diet on metabolism, with glucose intolerance and lipid disorders and vascular (especially microvessels) and cardiac functions. This work shows that HP-LC lead to equivalent cardiovascular alterations, as observed in very old age, and underlines the danger of such diet. Copyright © 2014 the American Physiological Society.

  18. Assay of amoxicillin and clavulanic acid, the components of Augmentin, in biological fluids with high-performance liquid chromatography.

    PubMed Central

    Foulstone, M; Reading, C

    1982-01-01

    Augmentin is a new antibacterial formulation comprised of amoxicillin and the beta-lactamase inhibitor clavulanic acid. In the present paper, the use of high-performance liquid chromatography (HPLC) to provide a rapid assay of the components of Augmentin in body fluids is described. Clavulanic acid was assayed by reacting the sample with imidazole, which readily produces a derivative absorbing at 311 nm. This derivative chromatographs on reverse-phase HPLC columns clear of interfering components in both human serum and urine. Concentrations of clavulanic acid as low as 0.1 microgram/ml were readily detectable in human serum with this procedure. There was no interference from amoxicillin, amoxicillin penicilloic acid, or the acid and alkali degradation products of clavulanic acid when this assay system was used. Amoxicillin in body fluids was assayed directly by HPLC without derivatization. The same chromatographic conditions were employed for the assay of amoxicillin and the clavulanic acid derivative, simplifying the methodology. Amoxicillin, however, was determined of the antibiotic per ml. An alkali blanking procedure for amoxicillin and clavulanic acid is also described which allows the detection of any underlying peaks which may cochromatograph. The use of ultrafiltration to remove protein from serum samples before HPLC was successfully applied to the assay of clavulanic acid and amoxicillin. Ultrafiltration is not an essential procedure for these assays, but it prolongs column life and reduces interference in the amoxicillin assay. Results obtained by HPLC were compared with those obtained by using microbiological assays. PMID:7181486

  19. Effect of γ irradiation on fungal load and aflatoxins reduction in red chillies

    NASA Astrophysics Data System (ADS)

    Iqbal, Shahzad Zafar; Bhatti, Ijaz Ahmad; Asi, Muhammad Rafique; Zuber, Mohammad; Shahid, Muhammad; Parveen, Ishrat

    2013-01-01

    Chillies are a very important cash crop of Pakistan. The effects of gamma irradiation on microbial load, aflatoxin B1 (AFB1) and total aflatoxins have been studied in chillies samples, collected from different districts of Punjab, Pakistan. Aflatoxins were analyzed using HPLC equipped with a fluorescence detector. The results revealed that among the Aspergillus species isolated, those belonging to section parasiticus were predominant. Gamma radiations of doses 2, 4 and 6 kGy were employed on fungi and chilli samples. The results have demonstrated that the dose of 6 kGy reduced the fungal load by 5 logs. Furthermore, 6 kGy reduced the level of AFB1 and total AFs in ground and whole chillies by 1-2 logs (α < 0.05).

  20. HPLC-Based Activity Profiling for GABAA Receptor Modulators in Extracts: Validation of an Approach Utilizing a Larval Zebrafish Locomotor Assay.

    PubMed

    Moradi-Afrapoli, Fahimeh; Ebrahimi, Samad Nejad; Smiesko, Martin; Hamburger, Matthias

    2017-05-26

    Gamma-aminobutyric acid type A (GABA A ) receptors are major inhibitory neurotransmitter receptors in the central nervous system and a target for numerous clinically important drugs used to treat anxiety, insomnia, and epilepsy. A series of allosteric GABA A receptor agonists was identified previously with the aid of HPLC-based activity profiling, whereby activity was tracked with an electrophysiological assay in Xenopus laevis oocytes. To accelerate the discovery process, an approach has been established for HPLC-based profiling using a larval zebrafish (Danio rerio) seizure model induced by pentylenetetrazol (PTZ), a pro-convulsant GABA A receptor antagonist. The assay was validated with the aid of representative GABAergic plant compounds and extracts. Various parameters that are relevant for the quality of results obtained, including PTZ concentration, the number of larvae, the incubation time, and the data analysis protocol, were optimized. The assay was then translated into an HPLC profiling protocol, and active compounds were tracked in extracts of Valeriana officinalis and Magnolia officinalis. For selected compounds the effects in the zebrafish larvae model were compared with data from in silico blood-brain barrier (BBB) permeability predictions, to validate the use for discovery of BBB-permeable natural products.

  1. The cytology, isozyme, HPLC fingerprint, and interspecific hybridization studies of genus epimedium (berberidaceae).

    PubMed

    Wang, Lin-Jiao; Sheng, Mao-Yin

    2013-01-01

    104 samples from 27 accessions belonging to 12 species of genus Epimedium were studied on the basis of cytology observation, POD (i.e., peroxide) isozyme, high performance liquid chromatography (i.e., HPLC) fingerprint, and interspecific hybridization. The cytology observation showed karyotypes of twelve species studied; all are 2A symmetry type of Stebbins standard and similar to each other, and except for karyotype of E. leptorrhizum which is 2n = 2x = 8m (2SAT) + 4sm, the rest are 2n = 2x = 6m (2SAT) + 6sm. Chromosomes C-banding of barrenwort species varies, with 15 to 22 bands, consisting of centromeric bands, intercalary bands, terminal bands, and middle satellite bands. Results of POD isozyme showed that the zymographs vary greatly and sixteen bands were detected in the eleven species, and each species has its own characteristic bands different from the others. Studies on the HPLC fingerprint showed that the HPLC fingerprint of different species has characteristic peaks, divided into two regions (retention time < 10 min and retention time > 10 min). Results of interspecific hybridization showed that crosses of any combination among seven species studied are successful and the rates of grain set vary greatly. Based on these results, the system and phylogeny of this genus were inferred.

  2. The Cytology, Isozyme, HPLC Fingerprint, and Interspecific Hybridization Studies of Genus Epimedium (Berberidaceae)

    PubMed Central

    Wang, Lin-Jiao; Sheng, Mao-Yin

    2013-01-01

    104 samples from 27 accessions belonging to 12 species of genus Epimedium were studied on the basis of cytology observation, POD (i.e., peroxide) isozyme, high performance liquid chromatography (i.e., HPLC) fingerprint, and interspecific hybridization. The cytology observation showed karyotypes of twelve species studied; all are 2A symmetry type of Stebbins standard and similar to each other, and except for karyotype of E. leptorrhizum which is 2n = 2x = 8m (2SAT) + 4sm, the rest are 2n = 2x = 6m (2SAT) + 6sm. Chromosomes C-banding of barrenwort species varies, with 15 to 22 bands, consisting of centromeric bands, intercalary bands, terminal bands, and middle satellite bands. Results of POD isozyme showed that the zymographs vary greatly and sixteen bands were detected in the eleven species, and each species has its own characteristic bands different from the others. Studies on the HPLC fingerprint showed that the HPLC fingerprint of different species has characteristic peaks, divided into two regions (retention time < 10 min and retention time > 10 min). Results of interspecific hybridization showed that crosses of any combination among seven species studied are successful and the rates of grain set vary greatly. Based on these results, the system and phylogeny of this genus were inferred. PMID:24349794

  3. SEPARATION OF THE MINOR FLAVONOLS FROM FLOS GOSSYPII BY HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY

    PubMed Central

    Yang, Yi; Zhao, Yongxin; Gu, Dongyu; Ayupbek, Amatjan; Huang, Yun; Dou, Jun; Ito, Yoichiro; Zhang, Tianyou; Aisa, Haji Akber

    2010-01-01

    An effective high-speed countercurrent chromatography (HSCCC) method was established for further separation and purification of four minor flavonols in addition to five major flavonols which were reported by our previous study from extracts of Flos Gossypii. HSCCC was performed with three two-phase solvent systems composed of n-hexane-ethyl acetate-methanol-water (7.5:15:6:7, v/v), (2.5:15:2:7, v/v) and (0:1:0:1, v/v). The separation was repeated 3 times, and 3.8 mg of 8-methoxyl-kaempferol-7-O-β-D-rhamnoside (HPLC purity 98.27%), 6.7 mg of astragalin (HPLC purity 94.18%), 3.3 mg of 4′-methoxyl-quercetin-7-O-β-D-glucoside (HPLC purity 94.30%) and 8.2 mg of hyperoside (HPLC purity 93.48%) were separated from 150 mg of the crude sample. The chemical structures of the flavonols were confirmed by MS, 1H NMR and 13C NMR. Meanwhile, the results indicated that the target compound with smaller K value (<0.5) can be separated by increasing column length of HSCCC. And four separation rules of flavonols according to the present study and references were summarized, which can be used as a useful guide for separation of flavonols by HSCCC. PMID:21494318

  4. Antimicrobial activity in the common seawhip, Leptogorgia virgulata (Cnidaria: Gorgonaceae).

    PubMed

    Shapo, Jacqueline L; Moeller, Peter D; Galloway, Sylvia B

    2007-09-01

    Antimicrobial activity was examined in the gorgonian Leptogorgia virgulata (common seawhip) from South Carolina waters. Extraction and assay protocols were developed to identify antimicrobial activity in crude extracts of L. virgulata. Detection was determined by liquid growth inhibition assays using Escherichia coli BL21, Vibrio harveyii, Micrococcus luteus, and a Bacillus sp. isolate. This represents the first report of antimicrobial activity in L. virgulata, a temperate/sub-tropical coral of the western Atlantic Ocean. Results from growth inhibition assays guided a fractionation scheme to identify active compounds. Reverse-phase HPLC, HPLC-mass spectrometry, and 1H and 13C NMR spectroscopy were used to isolate, purify, and characterize metabolites in antimicrobial fractions of L. virgulata. Corroborative HPLC-MS/NMR evidence validated the presence of homarine and a homarine analog, well-known emetic metabolites previously isolated from L. virgulata, in coral extracts. In subsequent assays, partially-purified L. virgulata fractions collected from HPLC-MS fractionation were shown to contain antimicrobial activity using M. luteus and V. harveyii. This study provides evidence that homarine is an active constituent of the innate immune system in L. virgulata. We speculate it may act synergistically with cofactors and/or congeners in this octocoral to mount a response to microbial invasion and disease.

  5. Assessment of the binding performance of histamine-imprinted microspheres by frontal analysis capillary electrophoresis.

    PubMed

    Romano, Edwin F; Quirino, Joselito P; Holdsworth, John L; So, Regina C; Holdsworth, Clovia I

    2017-05-01

    Frontal analysis capillary electrophoresis was used to evaluate the binding performance of molecularly imprinted microspheres (MIM) toward its template histamine and analogs at pH 7, and compared to the high performance liquid chromatographic method. In both methods, batch binding was employed and the binding parameters were calculated from the measured concentration of unbound amine analytes and afforded comparable histamine equilibrium dissociation constants (K d ∼ 0.4 mM). FACE was easily carried out at shorter binding equilibration time (i.e. 30 min) and without the need to separate the microspheres, circumventing laborious and, in the case of the system under study, inefficient sample filtration. It also allowed for competitive binding studies by virtue of its ability to distinctly separate intact microspheres and all tested amines which could not be resolved in HPLC. K d 's for nonimprinted (control) microspheres (NIM) from FACE and HPLC were also comparable (∼ 0.6 mM) but at higher histamine concentrations, HPLC gave lower histamine binding. This discrepancy was attributed to inefficient filtration of the batch binding samples prior to HPLC analysis resulting in an over-estimation of the concentration of free histamine brought about by the presence of unfiltered histamine-bound microspheres. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    PubMed

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. UV LED-based lightweight fixed-wavelength detector: for the development of a miniaturized high-performance liquid chromatography (HPLC) system (Erratum)

    NASA Astrophysics Data System (ADS)

    Guan, Wen Yin; Lee, Wei Yan; Liew, Mervyn Wing On; Tan, Soo Choon; Lim, Jit Kang

    2018-02-01

    Publisher's Note: This paper, originally published on 14 February, 2018, was replaced with a corrected/revised version on 30 March, 2018. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance. General discussion on the development of portable and miniaturized instrumentation for High Performance Liquid Chromatography (HPLC) is given, specifically the design of UV absorbance detector for field applications. UV/Vis absorption detectors are the most commonly used detector in HPLC for the identification of organic compounds, detection of peptides, proteins and nucleic acids. Opportunities for miniaturization arise from trends which focus on ease of use, portability, and application-specific instruments for example in environmental applications - detection of phenols (water pollutant) and contaminants. Further usage is such as detection of polycyclic aromatic hydrocarbons (PAHs) and carcinogens in edible oils and growth promoter residues in meat. Significant improvement in size and complexity were realized using a simplified optical configuration, efficient low-power LED driver circuit and detector electronics. Firstly, the detector's optical configuration is discussed as an essential part of the miniature fixed-wavelength design. UV-LED with different wavelengths can be installed interchangeably without the need for complicated assembly and precise alignment process. In the second part, each functional block of the detector hardware design are also discussed. The electronics consist of mainly sample photodiode and reference photodiode, Log-ratio amplifier and signal conditioning electronics built with precision analog design techniques and low-noise electronic components. Finally, baseline noise and drift measurements and chromatography performance are presented and the results are compared with conventional detector under identical conditions as benchmark. The advantages of miniaturized HPLC system are portability for onsite analysis, increased efficiency, lower solvent requirements and fully integrated separation and detection system.

  8. A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites.

    PubMed

    Xie, Li; Chen, Liqin; Gu, Pan; Wei, Lanlan; Kang, Xuejun

    2018-03-01

    The extraction and analysis of catecholamine neurotransmitters in biological fluids is of great importance in assessing nervous system function and related diseases, but their precise measurement is still a challenge. Many protocols have been described for neurotransmitter measurement by a variety of instruments, including high-pressure liquid chromatography (HPLC). However, there are shortcomings, such as complicated operation or hard-to-detect multiple targets, which cannot be avoided, and presently, the dominant analysis technique is still HPLC coupled with sensitive electrochemical or fluorimetric detection, due to its high sensitivity and good selectivity. Here, a detailed protocol is described for the pretreatment and detection of catecholamines with high pressure liquid chromatography with electrochemical detection (HPLC-ECD) in real urine samples of infants, using electrospun composite nanofibers composed of polymeric crown ether with polystyrene as adsorbent, also known as the packed-fiber solid phase extraction (PFSPE) method. We show how urine samples can be easily precleaned by a nanofiber-packed solid phase column, and how the analytes in the sample can be rapidly enriched, desorbed, and detected on an ECD system. PFSPE greatly simplifies the pretreatment procedures for biological samples, allowing for decreased time, expense, and reduction of the loss of targets. Overall, this work illustrates a simple and convenient protocol for solid-phase extraction coupled to an HPLC-ECD system for simultaneous determination of three monoamine neurotransmitters (norepinephrine (NE), epinephrine (E), dopamine (DA)) and two of their metabolites (3-methoxy-4-hydroxyphenylglycol (MHPG) and 3,4-dihydroxy-phenylacetic acid (DOPAC)) in infants' urine. The established protocol was applied to assess the differences of urinary catecholamines and their metabolites between high-risk infants with perinatal brain damage and healthy controls. Comparative analysis revealed a significant difference in urinary MHPG between the two groups, indicating that the catecholamine metabolites may be an important candidate marker for early diagnosis of cases at risk for brain damage in infants.

  9. 33 CFR 104.260 - Security systems and equipment maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Security systems and equipment... systems and equipment maintenance. (a) Security systems and equipment must be in good working order and inspected, tested, calibrated and maintained according to the manufacturer's recommendation. (b) The results...

  10. Research on multi - channel interactive virtual assembly system for power equipment under the “VR+” era

    NASA Astrophysics Data System (ADS)

    Ren, Yilong; Duan, Xitong; Wu, Lei; He, Jin; Xu, Wu

    2017-06-01

    With the development of the “VR+” era, the traditional virtual assembly system of power equipment has been unable to satisfy our growing needs. In this paper, based on the analysis of the traditional virtual assembly system of electric power equipment and the application of VR technology in the virtual assembly system of electric power equipment in our country, this paper puts forward the scheme of establishing the virtual assembly system of power equipment: At first, we should obtain the information of power equipment, then we should using OpenGL and multi texture technology to build 3D solid graphics library. After the completion of three-dimensional modeling, we can use the dynamic link library DLL package three-dimensional solid graphics generation program to realize the modularization of power equipment model library and power equipment model library generated hidden algorithm. After the establishment of 3D power equipment model database, we set up the virtual assembly system of 3D power equipment to separate the assembly operation of the power equipment from the space. At the same time, aiming at the deficiency of the traditional gesture recognition algorithm, we propose a gesture recognition algorithm based on improved PSO algorithm for BP neural network data glove. Finally, the virtual assembly system of power equipment can really achieve multi-channel interaction function.

  11. Comparison of gamma-oryzanol contents in crude rice bran oils from different sources by various determination methods.

    PubMed

    Yoshie, Ayano; Kanda, Ayato; Nakamura, Takahiro; Igusa, Hisao; Hara, Setsuko

    2009-01-01

    Although there are various determination methods for gamma -oryzanol contained in rice bran oil by absorptiometry, normal-phase HPLC, and reversed-phase HPLC, their accuracies and the correlations among them have not been revealed yet. Chloroform-containing mixed solvents are widely used as mobile phases in some HPLC methods, but researchers have been apprehensive about its use in terms of safety for the human body and the environment.In the present study, a simple and accurate determination method was developed by improving the reversed-phase HPLC method. This novel HPLC method uses methanol/acetonitrile/acetic acid (52/45/3 v/v/v), a non-chlorinated solvent, as the mobile phase, and shows an excellent linearity (y = 0.9527x + 0.1241, R(2) = 0.9974) with absorptiometry. The mean relative errors among the existing 3 methods and the novel method, determined by adding fixed amounts of gamma-oryzanol into refined rice salad oil, were -4.7% for the absorptiometry, -6.8% for the existing normal-phase HPLC, +4.6% for the existing reversed-phase HPLC, and -1.6% for the novel reversed-phase HPLC method. gamma -Oryzanol content in 12 kinds of crude rice bran oils obtained from different sources were determined by the four methods. The mean content of those oils were 1.75+/-0.18% for the absorptiometry, 1.29+/-0.11% for the existing normal-phase HPLC, 1.51+/-0.10% for the existing reversed-phase HPLC, and 1.54+/-0.19% for the novel reversed-phase HPLC method.

  12. 77 FR 67282 - Dinotefuran; Pesticide Tolerances for Emergency Exemptions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method is available. For the determination of residues of dinotefuran only, an HPLC/ultraviolet (UV) detection method is available. For the determination of only the metabolites (DN and UF), HPLC/MS and HPLC/MS/MS methods are available. These methods...

  13. 47 CFR 80.231 - Technical Requirements for Class B Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Identification System (AIS) equipment. 80.231 Section 80.231 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... § 80.231 Technical Requirements for Class B Automatic Identification System (AIS) equipment. (a) Class B Automatic Identification System (AIS) equipment must meet the technical requirements of IEC 62287...

  14. 47 CFR 80.231 - Technical Requirements for Class B Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Identification System (AIS) equipment. 80.231 Section 80.231 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... § 80.231 Technical Requirements for Class B Automatic Identification System (AIS) equipment. (a) Class B Automatic Identification System (AIS) equipment must meet the technical requirements of IEC 62287...

  15. 47 CFR 80.231 - Technical Requirements for Class B Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Identification System (AIS) equipment. 80.231 Section 80.231 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... § 80.231 Technical Requirements for Class B Automatic Identification System (AIS) equipment. (a) Class B Automatic Identification System (AIS) equipment must meet the technical requirements of IEC 62287...

  16. Application and preventive maintenance of neurology medical equipment in isfahan alzahra hospital.

    PubMed

    Alikhani, Parivash; Vesal, Sahar; Kashefi, Parviz; Pour, Ramin Etamadi; Khorvash, Fariborz; Askari, Gholamreza; Meamar, Rokhsareh

    2013-05-01

    Nowadays Medical equipment plays an important role in the treatment and in the medical education. Using outdated preventive maintenance (PM) system may cause problems in the cutting edge medical equipment, Nervous system disease's equipment (In diagnosis and treatment) which are crucial for every medical center. Based on above facts we focused on nervous system treat units' equipment and informed the supervisors and their colleagues about the latest equipment maintenance status and promoted methodical and correct method to be used for medical equipment maintenance. This research is an analytical descriptive and has been done on the base information from a particular time to past. We gathered our required information of 2009 from Alzahra Medical Center. We divided this research info 2 main phases. In the first phase, we picked out Neurosurgery and Neourology diseases medical equipment (diagnosis and therapy equipment) and in the second phase, we need to implement a methodical PM for every equipment. Research has shown that there are 19nervous system equipment in Alzahra Medical center, categorized in diagnostic (13 pcs), therapeutic (4 pcs) and diagnostic-therapeutic (2 pcs). As we declare in methods part of this research, we categorized medical equipment in Food and Drug Administration (FDA) segmentation. Capital-scarce equipment: Magnetic resonance imaging, Eco Doppler, Kamalaarak ultrasonic surgical aspirator, Stereotactic, computed tomography-scan, euroendoscope/vital-scarce equipment: Coblation, Sonoco, vaterjet/scarce equipment: Transcranial color Doppler, electroencephalogram, electromyography, surgical microscope. Survey of application and preventive maintenance of neurology medical equipment in Isfahan Alzahra hospital show there is no P.M system. Implementing a complete P.M system for this medical center is crucial to preventing cause problems for these medical equipment and decreasing maintenance costs and gaining uptime. Researchers of this article have tried to provide PM, use of texts, web and experts.

  17. An on-line monitoring system for navigation equipment

    NASA Astrophysics Data System (ADS)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  18. [Application of HIS Hospital Management System in Medical Equipment].

    PubMed

    Li, Yucheng

    2015-07-01

    To analyze the effect of HIS hospital management system in medical equipment. From April 2012 to 2013 in our hospital 5 100 sets of medical equipment as the control group, another 2013 in our hospital from April 2014 may 100 sets of medical equipment as the study group, comparative analysis of two groups of medical equipment scrap rate, usage, maintenance score and the score of benefit etc. Control group and taken to hospital information system, his research group equipment scrap rate, there was a significant difference, the research group of equipment maintenance score and efficiency scores were higher than those of the control group (P < 0.05), the study group of equipment maintenance score and efficiency scores were higher than those of the control group. HIS hospital management system for medical equipment management has positive clinical application value, can effectively improve the use of medical equipment, it is worth to draw and promote.

  19. Development of an HPLC method for determination of metabolic compounds in myocardial tissue.

    PubMed

    Volonté, M G; Yuln, G; Quiroga, P; Consolini, A E

    2004-05-28

    The determination of adenine nucleotides and creatine compounds has great importance in the characterization of ischemic myocardial injury and post-ischemic recovery. It was developed by an HPLC method for the quantification of creatine (Cr), creatine phosphate (CrP), hypoxanthine (HX), AMP, adenosine (Ad), ADP and ATP in isolated perfused rat hearts. The chromatographic conditions were: RP 18 column; mobile phase composed by KH(2)PO(4) (215 mM), tetrabutylammonium hydrogen sulfate (2.3mM), acetonitrile (4%) and KOH (1M 0.4%); flow rate 1 ml min(-1); temperature 25 degrees C; injection volume 20 microl; detection at 220 nm and height peak (HP) as the integration parameter. The method was validated by means of linearity and sensitivity evaluations, using calibration curves done with five concentration levels of each compound. The limits of quantification (LOQ) were also determined. The system precision was calculated as the coefficient of variation for five injections for each compound tested. The purity of the peaks was established using enzymatic peak shift analysis with hexokinase and creatine kinase and also comparing HP at various wavelengths. Frozen hearts were homogenized with a mechanical homogenizer for 3 min at 0 degrees C added with 5 ml of 0.4N HCLO(4). After precipitation with 0.8 ml of 2M KOH the extract was shaked for 2 min and later centrifuged at 0 degrees C for 10 min. The supernatant was kept on ice, filtrated and injected into the HPLC system. The results show that the method for the determination of Cr, CrP, HX, AMP, Ad, ADP and ATP by HPLC here described has good linearity, LOQ, precision, specificity and is simple and rapid to perform.

  20. Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC-ESI-MS-MS.

    PubMed

    Kertesz, Vilmos; Calligaris, David; Feldman, Daniel R; Changelian, Armen; Laws, Edward R; Santagata, Sandro; Agar, Nathalie Y R; Van Berkel, Gary J

    2015-08-01

    Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections, using a fully automated droplet-based liquid-microjunction surface-sampling-HPLC-ESI-MS-MS system for spatially resolved sampling, HPLC separation, and mass spectrometric detection. Excellent correlation was found between the protein distribution data obtained with this method and data obtained with matrix-assisted laser desorption/ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland. AVP was most abundant in the posterior pituitary gland region (neurohypophysis), and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH-secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH-secreting adenomas and in normal anterior adenohypophysis compared with non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis, as expected. This work reveals that a fully automated droplet-based liquid-microjunction surface-sampling system coupled to HPLC-ESI-MS-MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, including AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity, and specificity of this method support the potential of this basic technology, with further advancement, for assisting surgical decision-making. Graphical Abstract Mass spectrometry based profiling of hormones in human pituitary gland and tumor thin tissue sections.

  1. Radiation applications research and facilities in AECL research company

    NASA Astrophysics Data System (ADS)

    Iverson, S. L.

    In the 60's and 70's Atomic Energy of Canada had a very active R&D program to discover and develop applications of ionizing radiation. Out of this grew the technology underlying the company's current product line of industrial irradiators. With the commercial success of that product line the company turned its R&D attention to other activities. Presently, widespread interest in the use of radiation for food processing and the possibility of developing reliable and competitive machine sources of radiation hold out the promise of a major increase in industrial use of radiation. While many of the applications being considered are straightforward applications of existing knowledge, others depend on more subtle effects including combined effects of two or more agents. Further research is required in these areas. In March 1985 a new branch, Radiation Applications Research, began operations with the objective of working closely with industry to develop and assist the introduction of new uses of ionizing radiation. The Branch is equipped with appropriate analytical equipment including HPLC (high performance liquid chromatograph) and GC/MS (gas chromatograph/mass spectrometer) as well as a Gammacell 220 and an I-10/1, one kilowatt 10 MeV electron accelerator. The accelerator is located in a specially designed facility equipped for experimental irradiation of test quantities of packaged products as well as solids, liquids and gases in various configurations. A conveyor system moves the packaged products from the receiving area, through a maze, past the electron beam at a controlled rate and finally to the shipping area. Other necessary capabilities, such as gamma and electron dosimetry and a microbiology laboratory, have also been developed. Initial projects in areas ranging from food through environmental and industrial applications have been assessed and the most promising have been selected for further work. As an example, the use of charcoal adsorbent beds to concentrate the components of gas or liquid waste streams requiring treatment is showing promise as a method of significantly reducing the cost of radiation treatment for some effluents. A number of other projects are described.

  2. Ultra high performance liquid chromatography with ion-trap TOF-MS for the fast characterization of flavonoids in Citrus bergamia juice.

    PubMed

    Sommella, Eduardo; Pepe, Giacomo; Pagano, Francesco; Tenore, Gian Carlo; Dugo, Paola; Manfra, Michele; Campiglia, Pietro

    2013-10-01

    We have developed a fast ultra HPLC with ion-trap TOF-MS method for the analysis of flavonoids in Citrus bergamia juice. With respect to the typical methods for the analysis of these matrices based on conventional HPLC techniques, a tenfold faster separation was attained. The use of a core-shell particle column ensured high resolution within the fast analysis time of only 5 min. Unambiguous determination of flavonoid identity was obtained by the employment of a hybrid ion-trap TOF mass spectrometer with high mass accuracy (average error 1.69 ppm). The system showed good retention time and peak area repeatability, with maximum RSD% values of 0.36 and 3.86, respectively, as well as good linearity (R(2) ≥ 0.99). Our results show that ultra HPLC can be a useful tool for ultra fast qualitative/quantitative analysis of flavonoid compounds in citrus fruit juices. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. [Study on HPLC fingerprint of 11 Taraxacum species in northeast of China].

    PubMed

    Zhu, Dan; Zhao, Xin; Xu, Qiao; Ning, Wei

    2011-04-01

    To study the RP-HPLC fingerprints of 11 plants in the genus Taraxacum for their quality control. The fingerprints were determined using an Agilent 1100 series instrument system. Chromatographic analyses were performed on a Kromasil 100-5 C18 (4.6 mm x 250 mm, 5 microm) analytical column,eluted with methanol and water containing 0.5% acetic acid as the mobile phases in gradient elution at the flow rate of 1.0 mL x min(-1). The detection wavelength was 323 nm. The temperature of column was 35 degrees C. Eleven species of Taraxacum in northeast of China were detected respectively. Twenty-five common peaks existed in 11 RP-HPLC fingerprints. By comparing the retention time and the on-line UV spectra, peaks No. 10, No. 12, No. 16 and No. 25 were identified as chlorogenic acid, caffeic acid, p-coumaroy acid and luteolin respectively. The analytical method with good precision and reproducibility can be useful in the quality control of Taraxacum plants.

  4. Multichannel Detection in High-Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  5. Comparative HPLC/ESI-MS and HPLC/DAD study of different populations of cultivated, wild and commercial Gentiana lutea L.

    PubMed

    Mustafa, Ahmed M; Caprioli, Giovanni; Ricciutelli, Massimo; Maggi, Filippo; Marín, Rosa; Vittori, Sauro; Sagratini, Gianni

    2015-05-01

    The root of Gentiana lutea L., famous for its bitter properties, is often used in alcoholic bitter beverages, food products and traditional medicine to stimulate the appetite and improve digestion. This study presents a new, fast, and accurate HPLC method using HPLC/ESI-MS and HPLC/DAD for simultaneous analysis of iridoids (loganic acid), secoiridoids (gentiopicroside, sweroside, swertiamarin, amarogentin) and xanthones (isogentisin) in different populations of G.lutea L., cultivated in the Monti Sibillini National Park, obtained wild there, or purchased commercially. Comparison of HPLC/ESI-MS and HPLC/DAD indicated that HPLC/ESI-MS is more sensitive, reliable and selective. Analysis of twenty samples showed that gentiopicroside is the most dominant compound (1.85-3.97%), followed by loganic acid (0.11-1.30%), isogentisin (0.03-0.48%), sweroside (0.05-0.35%), swertiamarin (0.08-0.30%), and amarogentin (0.01-0.07%). The results confirmed the high quality of the G.lutea cultivated in the Monti Sibillini National Park. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Applications of HPLC/MS in the analysis of traditional Chinese medicines

    PubMed Central

    Li, Miao; Hou, Xiao-Fang; Zhang, Jie; Wang, Si-Cen; Fu, Qiang; He, Lang-Chong

    2012-01-01

    In China, traditional Chinese medicines (TCMs) have been used in clinical applications for thousands of years. The successful hyphenation of high-Performance liquid chromatography (HPLC) and mass spectrometry (MS) has been applied widely in TCMs and biological samples analysis. Undoubtedly, HPLC/MS technique has facilitated the understanding of the treatment mechanism of TCMs. We reviewed more than 350 published papers within the last 5 years on HPLC/MS in the analysis of TCMs. The present review focused on the applications of HPLC/MS in the component analysis, metabolites analysis, and pharmacokinetics of TCMs etc. 50% of the literature is related to the component analysis of TCMs, which show that this field is the most populär type of research. In the metabolites analysis, HPLC coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry has been demonstrated to be the powerful tool for the characterization of structural features and fragmentation behavior patterns. This paper presented a brief overview of the applications of HPLC/MS in the analysis of TCMs. HPLC/MS in the fingerprint analysis is reviewed elsewhere. PMID:29403684

  7. High-speed and high-resolution UPLC separation at zero degrees Celsius

    PubMed Central

    Wales, Thomas E.; Fadgen, Keith E.; Gerhardt, Geoff C.; Engen, John R.

    2008-01-01

    The conformational properties of proteins can be probed with hydrogen/deuterium exchange mass spectrometry (HXMS). In order to maintain the deuterium label during LC/MS analyses, chromatographic separation must be done rapidly (usually in under 8–10 minutes) and at zero degrees Celsius. Traditional RP-HPLC with ~3 micron particles has shown generally poor chromatographic performance under these conditions and thereby has been prohibitive for HXMS analyses of larger proteins and many protein complexes. Ultra performance liquid chromatography (UPLC) employs particles smaller than 2 microns in diameter to achieve superior resolution, speed, and sensitivity as compared to HPLC. UPLC has previously been shown to be compatible with the fast separation and low temperature requirements of HXMS. Here we present construction and validation of a custom UPLC system for HXMS. The system is based on the Waters nanoACQUITY platform and contains a Peltier-cooled module that houses the injection and switching valves, online pepsin digestion column, and C-18 analytical separation column. Single proteins in excess of 95 kDa and a four-protein mixture in excess of 250 kDa have been used to validate the performance of this new system. Near baseline resolution was achieved in 6 minute separations at 0 °C and displayed a median chromatographic peak width of ~2.7 sec at half height. Deuterium recovery was similar to that obtained using a conventional HPLC and icebath. This new system represents a significant advancement in HXMS technology that is expected to make the technique more accessible and mainstream in the near future. PMID:18672890

  8. Built-In Diagnostics (BID) Of Equipment/Systems

    NASA Technical Reports Server (NTRS)

    Granieri, Michael N.; Giordano, John P.; Nolan, Mary E.

    1995-01-01

    Diagnostician(TM)-on-Chip (DOC) technology identifies faults and commands systems reconfiguration. Smart microcontrollers operating in conjunction with other system-control circuits, command self-correcting system/equipment actions in real time. DOC microcontroller generates commands for associated built-in test equipment to stimulate unit of equipment diagnosed, collects and processes response data obtained by built-in test equipment, and performs diagnostic reasoning on response data, using diagnostic knowledge base derived from design data.

  9. Site-specific radical formation in DNA induced by Cu(II)-H2O2 oxidizing system, using ESR, Immuno-spin trapping, LC/MS and MS/MS

    PubMed Central

    Bhattacharjee, Suchandra; Deterding, Leesa J.; Chatterjee, Saurabh; Jiang, JinJie; Ehrenshaft, Marilyn; Lardinois, Olivier; Ramirez, Dario C.; Tomer, Kenneth B.; Mason, Ronald P.

    2011-01-01

    Oxidative stress-related damage to the DNA macromolecule produces a multitude of lesions that are implicated in mutagenesis, carcinogenesis, reproductive cell death and aging. Many of these lesions have been studied and characterized by various techniques. Of the techniques that are available, the comet assay, HPLC-EC, GC-MS, HPLC-MS and especially HPLC-MS/MS remain the most widely used and have provided invaluable information on these lesions. However, accurate measurement of DNA damage has been a matter of debate. In particular, there have been reports of artifactual oxidation leading to erroneously high damage estimates. Further, most of these techniques measure the end product of a sequence of events and thus provide only limited information on the initial radical mechanism. We report here a qualitative measurement of DNA damage induced by a Cu(II)-H2O2 oxidizing system using immuno spin-trapping (IST) with EPR, MS and MS/MS. The radical generated is trapped by DMPO immediately upon formation. The DMPO adduct formed is initially EPR active but subsequently is oxidized to the stable nitrone, which can then be detected by IST and further characterized by MS and MS/MS. PMID:21382477

  10. NF2 tumor suppressor gene: a comprehensive and efficient detection of somatic mutations by denaturing HPLC and microarray-CGH.

    PubMed

    Szijan, Irene; Rochefort, Daniel; Bruder, Carl; Surace, Ezequiel; Machiavelli, Gloria; Dalamon, Viviana; Cotignola, Javier; Ferreiro, Veronica; Campero, Alvaro; Basso, Armando; Dumanski, Jan P; Rouleau, Guy A

    2003-01-01

    The NF2 tumor suppressor gene, located in chromosome 22q12, is involved in the development of multiple tumors of the nervous system, either associated with neurofibromatosis 2 or sporadic ones, mainly schwannomas and meningiomas. In order to evaluate the role of the NF2 gene in sporadic central nervous system (CNS) tumors, we analyzed NF2 mutations in 26 specimens: 14 meningiomas, 4 schwannomas, 4 metastases, and 4 other histopathological types of neoplasms. Denaturing high performance liquid chromatography (denaturing HPLC) and comparative genomic hybridization on a DNA microarray (microarray- CGH) were used as scanning methods for small mutations and gross rearrangements respectively. Small mutations were identified in six out of seventeen meningiomas and schwannomas, one mutation was novel. Large deletions were detected in six meningiomas. All mutations were predicted to result in truncated protein or in the absence of a large protein domain. No NF2 mutations were found in other histopathological types of CNS tumors. These results provide additional evidence that mutations in the NF2 gene play an important role in the development of sporadic meningiomas and schwannomas. Denaturing HPLC analysis of small mutations and microarray-CGH of large deletions are complementary, fast, and efficient methods for the detection of mutations in tumor tissues.

  11. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.

  12. A novel multi-hyphenated analytical method to simultaneously determine xanthine oxidase inhibitors and superoxide anion scavengers in natural products.

    PubMed

    Qi, Jin; Sun, Li-Qiong; Qian, Steven Y; Yu, Bo-Yang

    2017-09-01

    Natural products, such as rosmarinic acid and apigenin, can act as xanthine oxidase inhibitors (XOIs) as well as superoxide anion scavengers, and have potential for treatment of diseases associated with high uric acid levels and oxidative stress. However, efficient simultaneous screening of these two bioactivities in natural products has been challenging. We have developed a novel method by assembling a multi-hyphenated high performance liquid chromatography (HPLC) system that combines a photo-diode array, chemiluminescence detector and a HPLC system with a variable wavelength detector, to simultaneously detect components that act as both XOIs and superoxide anion scavengers in natural products. Superoxide anion scavenging activity in the analyte was measured by on-line chemiluminescence chromatography based on pyrogallol-luminol oxidation, while xanthine oxidase inhibitory activity was determined by semi-on-line HPLC analysis. After optimizing multiple elements, including chromatographic conditions (e.g., organic solvent concentration and mobile phase pH), concentrations of xanthine/xanthine oxidase and reaction temperature, our validated analytical method was capable of mixed sample analysis. The final results from our method are presented in an easily understood visual format including comprehensive bioactivity data of natural products. Copyright © 2017. Published by Elsevier B.V.

  13. 78 FR 18416 - Sixth Meeting: RTCA Special Committee 226, Audio Systems and Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... 226, Audio Systems and Equipment AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION: Meeting Notice of RTCA Special Committee 226, Audio Systems and Equipment. SUMMARY... 226, Audio Systems and Equipment. DATES: The meeting will be held April 15-17, 2013 from 9:00 a.m.-5...

  14. Power Product Equipment Technician: Equipment Systems. Teacher Edition. Student Edition.

    ERIC Educational Resources Information Center

    Hilley, Robert

    This packet contains teacher and student editions on the topic of equipment systems, intended for the preparation of power product equipment technicians. This publication contains seven units: (1) principles of power transmission; (2) mechanical drive systems; (3) principles of fluid power; (4) hydraulic and pneumatic drive systems; (5) wheel and…

  15. [Application of information management system about medical equipment].

    PubMed

    Hang, Jianjin; Zhang, Chaoqun; Wu, Xiang-Yang

    2011-05-01

    Based on the practice of workflow, information management system about medical equipment was developed and its functions such as gathering, browsing, inquiring and counting were introduced. With dynamic and complete case management of medical equipment, the system improved the management of medical equipment.

  16. NASA ground terminal communication equipment automated fault isolation expert systems

    NASA Technical Reports Server (NTRS)

    Tang, Y. K.; Wetzel, C. R.

    1990-01-01

    The prototype expert systems are described that diagnose the Distribution and Switching System I and II (DSS1 and DSS2), Statistical Multiplexers (SM), and Multiplexer and Demultiplexer systems (MDM) at the NASA Ground Terminal (NGT). A system level fault isolation expert system monitors the activities of a selected data stream, verifies that the fault exists in the NGT and identifies the faulty equipment. Equipment level fault isolation expert systems are invoked to isolate the fault to a Line Replaceable Unit (LRU) level. Input and sometimes output data stream activities for the equipment are available. The system level fault isolation expert system compares the equipment input and output status for a data stream and performs loopback tests (if necessary) to isolate the faulty equipment. The equipment level fault isolation system utilizes the process of elimination and/or the maintenance personnel's fault isolation experience stored in its knowledge base. The DSS1, DSS2 and SM fault isolation systems, using the knowledge of the current equipment configuration and the equipment circuitry issues a set of test connections according to the predefined rules. The faulty component or board can be identified by the expert system by analyzing the test results. The MDM fault isolation system correlates the failure symptoms with the faulty component based on maintenance personnel experience. The faulty component can be determined by knowing the failure symptoms. The DSS1, DSS2, SM, and MDM equipment simulators are implemented in PASCAL. The DSS1 fault isolation expert system was converted to C language from VP-Expert and integrated into the NGT automation software for offline switch diagnoses. Potentially, the NGT fault isolation algorithms can be used for the DSS1, SM, amd MDM located at Goddard Space Flight Center (GSFC).

  17. 14 CFR 171.259 - Performance requirements: General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... components: (1) C-Band (5000 MHz-5030 MHz) localizer equipment, associated monitor system, and remote indicator equipment; (2) C-Band (5220 MHz-5250 MHz) glide path equipment, associated monitor system, and remote indicator equipment; (3) VHF marker beacons (75 MHz), associated monitor systems, and remote...

  18. 14 CFR 171.259 - Performance requirements: General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... components: (1) C-Band (5000 MHz-5030 MHz) localizer equipment, associated monitor system, and remote indicator equipment; (2) C-Band (5220 MHz-5250 MHz) glide path equipment, associated monitor system, and remote indicator equipment; (3) VHF marker beacons (75 MHz), associated monitor systems, and remote...

  19. 14 CFR 171.259 - Performance requirements: General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... components: (1) C-Band (5000 MHz-5030 MHz) localizer equipment, associated monitor system, and remote indicator equipment; (2) C-Band (5220 MHz-5250 MHz) glide path equipment, associated monitor system, and remote indicator equipment; (3) VHF marker beacons (75 MHz), associated monitor systems, and remote...

  20. 14 CFR 171.259 - Performance requirements: General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... components: (1) C-Band (5000 MHz-5030 MHz) localizer equipment, associated monitor system, and remote indicator equipment; (2) C-Band (5220 MHz-5250 MHz) glide path equipment, associated monitor system, and remote indicator equipment; (3) VHF marker beacons (75 MHz), associated monitor systems, and remote...

  1. 14 CFR 121.358 - Low-altitude windshear system equipment requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Low-altitude windshear system equipment... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.358 Low-altitude windshear system equipment requirements. (a) Airplanes manufactured after January...

  2. 14 CFR 121.358 - Low-altitude windshear system equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Low-altitude windshear system equipment... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.358 Low-altitude windshear system equipment requirements. (a) Airplanes manufactured after January...

  3. 14 CFR 121.358 - Low-altitude windshear system equipment requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Low-altitude windshear system equipment... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.358 Low-altitude windshear system equipment requirements. (a) Airplanes manufactured after January...

  4. 14 CFR 121.358 - Low-altitude windshear system equipment requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Low-altitude windshear system equipment... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.358 Low-altitude windshear system equipment requirements. (a) Airplanes manufactured after January...

  5. 14 CFR 121.358 - Low-altitude windshear system equipment requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Low-altitude windshear system equipment... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.358 Low-altitude windshear system equipment requirements. (a) Airplanes manufactured after January...

  6. HPLC-DAD-MS identification of bioactive secondary metabolites from Ferula communis roots.

    PubMed

    Arnoldi, Lolita; Ballero, Mauro; Fuzzati, Nicola; Maxia, Andrea; Mercalli, Enrico; Pagni, Luca

    2004-06-01

    A simple HPLC method was developed to distinguish between 'poisonous' and 'non-poisonous' chemotypes of Ferula communis. The method was performed on a C8 reverse phase analytical column using a binary eluent (aqueous TFA 0.01%-TFA 0.01% in acetonitrile) under gradient condition. The two chemotypes showed different fingerprints. The identification of five coumarins and eleven daucane derivatives by HPLC-diode array detection (HPLC-DAD) and HPLC-MS is described. A coumarin, not yet described, was detected. Copyright 2004 Elsevier B.V.

  7. [Identification of impurity peaks in the HPLC chromatogram by LC-MS and two-dimensional chromatographic correlation spectroscopy].

    PubMed

    Chen, Zhen-Zhen; Zhang, Dou-Sheng; Wang, Nan; Feng, Fang; Hu, Chang-Qin

    2012-04-01

    A novel qualitative analytical method by using two-dimensional chromatographic correlation spectroscopy techniques for recognizing impurity peaks of HPLC methods of quality control and LC-MS chromatographic system was established. The structures of major degradation products of ceftizoxime and cefdinir were identified by LC-MS and MassWorks application; the standard chromatographic and spectral data of the degradation impurities were obtained by high-performance liquid chromatography with diode array detection. The impurity peaks of two-dimensional chromatography were matched by comparison of spectra and calculating correlation coefficients. Peaks in chromatography can be identified accurately and rapidly in different chromatographic systems such as column and mobile phase changed. The method provides a new way and thought to identify the peaks in quality control of impurities without reference impurity substances.

  8. Phototoxicity testing by online irradiation and HPLC.

    PubMed

    Schröder, Sven; Surmann, J P

    2006-11-01

    A high-performance liquid chromatography (HPLC) system was developed for the determination of drug photostability and phototoxicity based on an automated column-switching system with aqueous online UV-A irradiation and hyphenated organic separation of the drug and its photoproducts. The photoreactor is built with an poly(ethylene-co-tetrafluoroethylene) (ETFE) reaction coil knitted around a UV-A light source. The chromatographic separation was performed with two special C18 columns, which are also suitable for using with pure water as eluent. Degradation of chlorpromazine (CPZ) by ultraviolet light was investigated at pH 7 and pH 3. Furthermore chlorpromazine was irradiated in the presence of guanosine-5-monophosphate (GMP) in pH 7 buffered solution, leading to a new photoproduct. In the pH 3 irradiation studies of CPZ and GMP, no reaction was detected between the molecules.

  9. 78 FR 57673 - Eighth Meeting: RTCA Special Committee 226, Audio Systems and Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... Committee 226, Audio Systems and Equipment AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION: Meeting Notice of RTCA Special Committee 226, Audio Systems and Equipment. SUMMARY... Committee 226, Audio Systems and Equipment. DATES: The meeting will be held October 8-10, 2012 from 9:00 a.m...

  10. 77 FR 37732 - Fourteenth Meeting: RTCA Special Committee 224, Audio Systems and Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ... Committee 224, Audio Systems and Equipment AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION: Meeting Notice of RTCA Special Committee 224, Audio Systems and Equipment. SUMMARY... Committee 224, Audio Systems and Equipment. DATES: The meeting will be held July 11, 2012, from 10 a.m.-4 p...

  11. Army Logistics Systems: Opportunities to Improve the Accuracy of the Army’s Major Equipment Item System

    DTIC Science & Technology

    1998-01-01

    consolidated financial statements of the federal government, we are reviewing the accuracy of data in the military services’ financial/logistical systems that are used to provide property, plant, and equipment information to the financial statements. The Army uses the Continuing Balance System-Expanded (CBSX) as its central logistics system for reporting the types, quantities, and location of equipment; monitoring the equipment readiness of its warfighting units; and filling equipment shortages in those units scheduled for mobilization. In addition,

  12. Identification of the convulsant opiate thebaine in mammalian brain.

    PubMed Central

    Kodaira, H; Lisek, C A; Jardine, I; Arimura, A; Spector, S

    1989-01-01

    The convulsant opiate thebaine, an intermediate of morphine biosynthesis, was purified from bovine brain to homogeneity by gel filtration and high-performance liquid chromatography (HPLC) monitored by a radioimmunoassay. The immunoreactive material behaved identically to standard thebaine in two HPLC systems and was confirmed to be thebaine by combined gas chromatography/mass spectrometry. To our knowledge, the presence of thebaine in mammalian tissue has not been demonstrated previously. Codeine and morphine were also found to exist in ovine brain. The presence of thebaine in ovine brain provides strong evidence that morphine and codeine, in various mammalian tissues, are of endogenous origin and actually biosynthesized from a precursor. Images PMID:2911601

  13. [Determination of homocysteine level in plasma by high performance liquids chromatography with fluorescence detection].

    PubMed

    Da, Xu; Qian, Ling-Jia

    2005-08-01

    To establish a method for detection of plasma total homocysteine with HPLC. The chromatography analysis was carried out using a Symmetry Shield RP18. The mobile phase was sodium acetate (0.08 mol/L) and methanol (1%) and we utilized a HPLC system with fluorescence detection of plasma homocysteine derivatized from reaction with 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-F). The average recoveries were 95.8 - 100.8% and the relative standard deviations were 1.2-2.0%. The results showed it to be a rapid and accurate method for the determination of homocysteine level in plasma.

  14. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  15. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    PubMed

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Ion chromatography for the precise analysis of chloride and sodium in sweat for the diagnosis of cystic fibrosis.

    PubMed

    Doorn, J; Storteboom, T T R; Mulder, A M; de Jong, W H A; Rottier, B L; Kema, I P

    2015-07-01

    Measurement of chloride in sweat is an essential part of the diagnostic algorithm for cystic fibrosis. The lack in sensitivity and reproducibility of current methods led us to develop an ion chromatography/high-performance liquid chromatography (IC/HPLC) method, suitable for the analysis of both chloride and sodium in small volumes of sweat. Precision, linearity and limit of detection of an in-house developed IC/HPLC method were established. Method comparison between the newly developed IC/HPLC method and the traditional Chlorocounter was performed, and trueness was determined using Passing Bablok method comparison with external quality assurance material (Royal College of Pathologists of Australasia). Precision and linearity fulfill criteria as established by UK guidelines are comparable with inductively coupled plasma-mass spectrometry methods. Passing Bablok analysis demonstrated excellent correlation between IC/HPLC measurements and external quality assessment target values, for both chloride and sodium. With a limit of quantitation of 0.95 mmol/L, our method is suitable for the analysis of small amounts of sweat and can thus be used in combination with the Macroduct collection system. Although a chromatographic application results in a somewhat more expensive test compared to a Chlorocounter test, more accurate measurements are achieved. In addition, simultaneous measurements of sodium concentrations will result in better detection of false positives, less test repeating and thus faster and more accurate and effective diagnosis. The described IC/HPLC method, therefore, provides a precise, relatively cheap and easy-to-handle application for the analysis of both chloride and sodium in sweat. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. Development of augmented reality system for servicing electromechanical equipment

    NASA Astrophysics Data System (ADS)

    Zhukovskiy, Y.; Koteleva, N.

    2018-05-01

    Electromechanical equipment is widely used. It is used in industrial enterprises, in the spheres of public services, in everyday life, etc. Maintenance servicing of electromechanical equipment is an important part of its life cycle. High-quality and timely service can extend the life of the electromechanical equipment. The creation of special systems that simplify the process of servicing electromechanical equipment is an urgent task. Such systems can shorten the time for maintenance of electrical equipment, and, therefore, reduce the cost of maintenance in general. This article presents an analysis of information on the operation of service services for maintenance and repair of electromechanical equipment, identifies the list of services, and estimates the time required to perform basic service operations. The structure of the augmented reality system is presented, the ways of interaction of the augmented reality system with the automated control systems working at the enterprise are presented.

  18. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    PubMed

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  19. Semiquantitative determination of ergot alkaloids in seed, straw, and digesta samples using a competitive enzyme-linked immunosorbent assay.

    PubMed

    Schnitzius, J M; Hill, N S; Thompson, C S; Craig, A M

    2001-05-01

    Ergot alkaloids present in endophyte-infected (E+) tall fescue cause fescue toxicosis and other toxic effects in livestock that consume infected plant tissue, leading to significant financial losses in livestock production each year. The predominant method currently in use for quantifying ergot alkaloid content in plant tissue is through high-performance liquid chromatography (HPLC), which quantifies the amount of ergovaline, one of many ergot alkaloids in E+ plant tissue. The enzyme-linked immunosorbent assay (ELISA) method used in this study detects quantities of nonspecific ergot alkaloids and therefore accounts for greater amounts of the total ergot alkaloid content in E+ tissue than does HPLC. The ELISA can also be used to more expediently analyze a larger number of forage samples without sophisticated and costly analytical equipment and therefore could be more desirable in a diagnostic setting. The purpose of this study was to evaluate the between-day and within-run variability of the ELISA and to determine the binding efficiency of 6 ergot alkaloids to the 15F3.E5 antibody used in the competitive ELISA to ascertain its feasibility as a quick analysis tool for ergot alkaloids. Straw samples had an average coefficient of variation (CV) for concentration of 10.2% within runs and 18.4% between runs, and the seed samples had an average CV for concentration of 13.3% within runs and 24.5% between runs. The grass tissue-based lysergic acid standard curve calculated from the ELISA had an average r2 of 0.99, with a CV of 2.1%. Ergocryptine, ergocristine, ergocornine, and ergotamine tartrate did not bind strongly to the 15F3.E5 antibody because of the presence of large side groups on these molecules, which block their binding to the antibody, whereas ergonovine and ergonovine maleate were bound much more efficiently because of their structural similarity to lysergic acid. Clarified rumen fluid was tested as an additional matrix for use in the ergot alkaloid competitive ELISA to determine whether future livestock metabolism experiments on the postingestion fate of ergot alkaloids in ruminants could utilize this assay as a quick screening tool for the presence of nonspecific ergot alkaloids in rumen fluid. HPLC and ELISA procedures were compared for their ability in determining ergot alkaloid toxicity based on the repeatability of the procedures and on the specific compounds they measure. The ratio of ELISA concentration to HPLC concentration (ergovaline) varied from 2.00 to 2.81 in seed samples and from 0.62 to 8.66 in straw samples, showing no consistent pattern between the 2 methods. Based on the lack of data at present for the identity of the toxin causing endophyte toxicosis and the lack of agreement between the ergovaline HPLC and ELISA analyses for ergot alkaloids, each method is equally valid as an indicator of toxicityand is the best means for determining the quantity of the specific toxin(s) they measure.

  20. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2013-10-01 2013-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  1. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2010-10-01 2010-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  2. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2014-10-01 2014-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  3. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2011-10-01 2011-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  4. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2012-10-01 2012-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  5. 46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Equipment safety grounding (bonding) conductors. 111.05... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must...

  6. 46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Equipment safety grounding (bonding) conductors. 111.05... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must...

  7. 46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Equipment safety grounding (bonding) conductors. 111.05... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must...

  8. Profiling of components of rhizoma et radix polygoni cuspidati by high-performance liquid chromatography with ultraviolet diode-array detector and ion trap/time-of-flight mass spectrometric detection.

    PubMed

    Fu, Jinfeng; Wang, Min; Guo, Huimin; Tian, Yuan; Zhang, Zunjian; Song, Rui

    2015-01-01

    Rhizoma et Radix Polygoni Cuspidati (Huzhang in Chinese, HZ) is a traditional medicinal plant in China. Many of the components of HZ have been proved to be bioactive while it is difficult to conduct a comprehensive chemical profiling of HZ as a consequence of the absence of efficient separation system and sensitive detective means. We developed a simple and effective method for comprehensive characterization of constituents in HZ. To develop a simple and effective method to characterize the components in HZ and provide useful information for subsequent metabolic studies of HZ. The components in HZ aqueous extract were characterized by using high performance liquid chromatography with UV diode-array detector (HPLC-DAD) and ion trap/time-of-flight mass spectrometric detection (HPLC-IT/TOF). Stilbenes, anthraquinones, gallates and tannins, naphthalenes and some other compounds were identified and confirmed by diagnostic fragment ions with accurate mass measurements, characteristic fragmentation pathways and relevant published literatures. Among the 238 constituents detected in HZ, a total number of 74 constituents were identified unambiguously or tentatively, including 29 compounds reported for the first time in HZ. The identification and structure elucidation of these chemicals provided essential data for quality control and further in vivo metabolic studies of HZ. Key words: Polygonum cuspidatum, HPLC-DAD, HPLC-IT/TOF, qualitative analysis.

  9. Simultaneous Speciation of Arsenic, Selenium, and Chromium by HPLC-ICP-MS

    USGS Publications Warehouse

    Wolf, Ruth E.; Morman, Suzette A.; Morrison, Jean M.; Lamothe, Paul J.

    2008-01-01

    An adaptation of an analytical method developed for chromium speciation has been utilized for the simultaneous determination of As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI) species using high performance liquid chromatography (HPLC) separation with ICP-MS detection. Reduction of interferences for the determination of As, Se, and Cr by ICP-MS is a major consideration for this method. Toward this end, a Dynamic Reaction Cell (DRC) ICP-MS system was used to detect the species eluted from the chromatographic column. A variety of reaction cell gases and conditions may be utilized, and the advantages and limitations of the gases tested to date will be presented and discussed. The separation and detection of the As, Se, and Cr species of interest can be achieved using the same chromatographic conditions in less than 2 minutes by complexing the Cr(III) with EDTA prior to injection on the HPLC column. Practical aspects of simultaneous speciation analysis will be presented and discussed, including issues with HPLC sample vial contamination, standard and sample contamination, species stability, and considerations regarding sample collection and preservation methods. The results of testing to determine the method's robustness to common concomitant element and anion effects will also be discussed. Finally, results will be presented using the method for the analysis of a variety of environmental and geological samples including waters, soil leachates and simulated bio-fluid leachates.

  10. Retention behavior of long chain quaternary ammonium homologues and related nitroso-alkymethylamines

    USGS Publications Warehouse

    Abidi, S.L.

    1985-01-01

    Several chromatographic methods have been utilized to study the retentionbehavior of a homologous series of n-alkylbenzyldimethylammonium chlorides (ABDAC) and the corresponding nitroso-n-alkylmethylamines (NAMA). Linear correlation of the logarithmic capacity factor (k') with the number of carbons in the alkyl chain provides useful information on both gas chromatographic (GC) and high-performance liquid chromatographich (HPLC) retention parameters of unknown components. Under all conditions empolyed, GC methodology has proved effective in achieving complete resolution of the homologous mixture of NMA despite its obvious inadequacy in the separation of E-Z configurational isomers. Conversely, normal-phase HPLC on silica demonstrates that the selectivity (a) value for an E-Z pair is much higher than that for an adjacent homologous pair. In the reversed-phase HPLC study, three different silica-based column systems were examined under various mobile phase conditions. The extent of variation in k' was found to be a function of the organic modifier, counter-ion concentration, eluent pH, nature of counter-ion, and the polarity and type of stationary phase. The k'—[NaClO4] profiles showed similar trends between the ABDAC and the NAMA series, supporting the dipolar electronic structures of the latter compounds. Mobile phase and stationary phase effects on component separation are described. The methodology presented establishes the utility of HPLC separation techniques as versatile analytical tools for practical application.

  11. [Study on the fingerprint of Morus alba from different habitats by HPLC].

    PubMed

    Chen, Cheng; Li, Hong-Bo; Wang, Liu-Ping; Li, Yun-Rong; Xin, Ning

    2012-12-01

    To establish HPLC fingerprint of Morus alba from different habitats by HPLC and provide basis for its quality control. HPLC analysis was performed on an Agilent XDB C18 Column (4.6 mm x 250 mm, 5 microm), gradient eluted composed of acetonitrile and 0.3% phosphate acid. The column temperature was set at 35 degrees C and the flow rate was 0.5 mL/min. The detective wavelength was 290 nm. The HPLC fingerprint for 10 batches of Morus alba was studied on their similarity. There were twelve common peaks in the fingerprint. The similarity of 7 batches was above 0.9 and the other batches had low similarity. The HPLC fingerprint can be used for quality control of Morus alba with high characteristics and specificity.

  12. Cocoa and Grape Seed Byproducts as a Source of Antioxidant and Anti-Inflammatory Proanthocyanidins

    PubMed Central

    Cádiz-Gurrea, María De La Luz; Borrás-Linares, Isabel; Lozano-Sánchez, Jesús; Joven, Jorge; Fernández-Arroyo, Salvador; Segura-Carretero, Antonio

    2017-01-01

    Phenolic compounds, which are secondary plant metabolites, are considered an integral part of the human diet. Physiological properties of dietary polyphenols have come to the attention in recent years. Especially, proanthocyanidins (ranging from dimers to decamers) have demonstrated potential interactions with biological systems, such as antiviral, antibacterial, molluscicidal, enzyme-inhibiting, antioxidant, and radical-scavenging properties. Agroindustry produces a considerable amount of phenolic-rich sources, and the ability of polyphenolic structures to interacts with other molecules in living organisms confers their beneficial properties. Cocoa wastes and grape seeds and skin byproducts are a source of several phenolic compounds, particularly mono-, oligo-, and polymeric proanthocyanidins. The aim of this work is to compare the phenolic composition of Theobroma cacao and Vitis vinifera grape seed extracts by high pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer and equipped with an electrospray ionization interface (HPLC-ESI-QTOF-MS) and its phenolic quantitation in order to evaluate the proanthocyanidin profile. The antioxidant capacity was measured by different methods, including electron transfer and hydrogen atom transfer-based mechanisms, and total phenolic and flavan-3-ol contents were carried out by Folin–Ciocalteu and Vanillin assays. In addition, to assess the anti-inflammatory capacity, the expression of MCP-1 in human umbilical vein endothelial cells was measured. PMID:28208630

  13. Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing.

    PubMed

    Adam, T W; Clairotte, M; Streibel, T; Elsasser, M; Pommeres, A; Manfredi, U; Carriero, M; Martini, G; Sklorz, M; Krasenbrink, A; Astorga, C; Zimmermann, R

    2012-07-01

    Resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS) is a robust method for real-time analysis of monocyclic and polycyclic aromatic hydrocarbons in complex emissions. A mobile system has been developed which enables direct analysis on site. In this paper, we utilize a multicomponent calibration scheme based on the analytes' photo-ionisation cross-sections relative to a calibrated species. This allows semi-quantification of a great number of components by only calibrating one compound of choice, here toluene. The cross-sections were determined by injecting nebulised solutions of aromatic compounds into the TOF-MS ion source with the help of a HPLC pump. Then, REMPI-TOF-MS was implemented at various chassis dynamometers and test cells and the exhaust of the following vehicles and engines investigated: a compression ignition light-duty (LD) passenger car, a compression ignition LD van, two spark ignition LD passenger cars, 2 two-stroke mopeds, and a two-stroke engine of a string gas trimmer. The quantitative time profiles of benzene are shown. The results indicate that two-stroke engines are a significant source for toxic and cancerogenic compounds. Air pollution and health effects caused by gardening equipment might still be underestimated.

  14. Simultaneous identification of synthetic and natural dyes in different food samples by UPLC-MS

    NASA Astrophysics Data System (ADS)

    Mandal, Badal Kumar; Mathiyalagan, Siva; Dalavai, Ramesh; Ling, Yong-Chien

    2017-11-01

    Fast foods and variety food items are populating among the food lovers. To improve the appearance of the food product in surviving gigantic competitive environment synthetic or natural food dyes are added to food items and beverages. Although regulatory bodies permit addition of natural colorants due to its safe and nontoxic nature in food, synthetic dyes are stringently controlled in all food products due to their toxicity by regulatory bodies. Artificial colors are need certification from the regulatory bodies for human consumption. To analyze food dyes in different food samples many analytical techniques are available like high pressure liquid chromatography (HPLC), thin layer chromatography (TLC), spectroscopic and gas chromatographic methods. However all these reported methods analyzed only synthetic dyes or natural dyes. Not a single method has analyzed both synthetic and natural dyes in a single run. In this study a robust ultra-performance liquid chromatographic method for simultaneous identification of 6 synthetic dyes (Tartrazine, Indigo carmine, Briliant blue, Fast green, malachite green, sunset yellow) and one natural dye (Na-Cu-Chlorophyllin) was developed using acquitic UPLC system equipped with Mass detector and acquity UPLC HSS T3 column (1.8 μm, 2.1 × 50 mm, 100Å). All the dyes were separated and their masses were determined through fragments’ masses analyses.

  15. Cocoa and Grape Seed Byproducts as a Source of Antioxidant and Anti-Inflammatory Proanthocyanidins.

    PubMed

    Cádiz-Gurrea, María De La Luz; Borrás-Linares, Isabel; Lozano-Sánchez, Jesús; Joven, Jorge; Fernández-Arroyo, Salvador; Segura-Carretero, Antonio

    2017-02-10

    Phenolic compounds, which are secondary plant metabolites, are considered an integral part of the human diet. Physiological properties of dietary polyphenols have come to the attention in recent years. Especially, proanthocyanidins (ranging from dimers to decamers) have demonstrated potential interactions with biological systems, such as antiviral, antibacterial, molluscicidal, enzyme-inhibiting, antioxidant, and radical-scavenging properties. Agroindustry produces a considerable amount of phenolic-rich sources, and the ability of polyphenolic structures to interacts with other molecules in living organisms confers their beneficial properties. Cocoa wastes and grape seeds and skin byproducts are a source of several phenolic compounds, particularly mono-, oligo-, and polymeric proanthocyanidins. The aim of this work is to compare the phenolic composition of Theobroma cacao and Vitis vinifera grape seed extracts by high pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer and equipped with an electrospray ionization interface (HPLC-ESI-QTOF-MS) and its phenolic quantitation in order to evaluate the proanthocyanidin profile. The antioxidant capacity was measured by different methods, including electron transfer and hydrogen atom transfer-based mechanisms, and total phenolic and flavan-3-ol contents were carried out by Folin-Ciocalteu and Vanillin assays. In addition, to assess the anti-inflammatory capacity, the expression of MCP-1 in human umbilical vein endothelial cells was measured.

  16. Quantification of Triacylglycerol Positional Isomers in Rat Milk.

    PubMed

    Watanabe, Natsuko; Nagai, Toshiharu; Mizobe, Hoyo; Yoshinaga, Kazuaki; Yoshida, Akihiko; Kitamura, Yohei; Shimizu, Takashi; Beppu, Fumiaki; Gotoh, Naohiro

    2016-12-01

    The absolute amount of triacylglycerol (TAG) positional isomers was analyzed in rat milk fat, a representative of non-ruminant milk fat, using a HPLC-UV-atmospheric pressure chemical ionization-MS/MS system equipped with an octacosyl silylation column or polymeric ODS column. TAGs consisting of two oleic acids (O) and one palmitic acid (P) were the most abundant. In particular, β-OPO, a TAG binding P at the β-position (sn-2) and two Os at the α-positions (sn-1/3), was prominent. The β-OPO content decreased over time, while a TAG consisting of two Ps and one capric acid, a medium-chain fatty acid, increased. TAGs consisting of two Ps and one docosahexaenoic acid were present in small amounts and decreased with time. These results indicated that the recombination of fatty acids in TAGs in milk fat occurs in the mother, and is thought to depend on the infant's stage of growth, in response to their nutritional needs. It was also demonstrated that medium-chain fatty acids were mainly located at the α-position (sn-3), while Ps were mainly located at the β-position (sn-2). Therefore, the combination and binding positions of fatty acids of TAG are considered very important in infant nutrition.

  17. HPLC studio: a novel software utility to perform HPLC chromatogram comparison for screening purposes.

    PubMed

    García, J B; Tormo, José R

    2003-06-01

    A new tool, HPLC Studio, was developed for the comparison of high-performance liquid chromatography (HPLC) chromatograms from microbial extracts. The new utility makes it possible to create a virtual chromatogram by mixing up to 20 individual chromatograms. The virtual chromatogram is the first step in establishing a ranking of the microbial fermentation conditions based on either the area or diversity of HPLC peaks. The utility was used to maximize the diversity of secondary metabolites tested from a microorganism and therefore increase the chances of finding new lead compounds in a drug discovery program.

  18. Ginsenoside extraction from Panax quinquefolium L. (American ginseng) root by using ultrahigh pressure.

    PubMed

    Zhang, Shouqin; Chen, Ruizhan; Wu, Hua; Wang, Changzheng

    2006-04-11

    A new method of ultrahigh pressure extraction (UPE) was used to extract the ginsenosides from Panax quinquefolium L. (American ginseng) root at room temperature. Several solvents, including water, ethanol, methanol, and n-butanol were used in the UPE. The ginsenosides were quantified by a HPLC equipped with UV-vis detector. The results showed that ethanol is the most efficient solvent among the used ones. Compared with other methods, i.e., Soxhlet extraction, heat reflux extraction, ultrasound-assisted extraction, microwave-assisted extraction, and supercritical CO2 extraction, the UPE has the highest extraction yield in the shortest time. The extraction yield of 0.861% ginsenoside-Rc in 2 min was achieved by the UPE, while the yields of 0.284% and 0.661% were obtained in several hours by supercritical CO2 extraction and the heat reflux extraction, respectively.

  19. Modeling systematic errors: polychromatic sources of Beer-Lambert deviations in HPLC/UV and nonchromatographic spectrophotometric assays.

    PubMed

    Galli, C

    2001-07-01

    It is well established that the use of polychromatic radiation in spectrophotometric assays leads to excursions from the Beer-Lambert limit. This Note models the resulting systematic error as a function of assay spectral width, slope of molecular extinction coefficient, and analyte concentration. The theoretical calculations are compared with recent experimental results; a parameter is introduced which can be used to estimate the magnitude of the systematic error in both chromatographic and nonchromatographic spectrophotometric assays. It is important to realize that the polychromatic radiation employed in common laboratory equipment can yield assay errors up to approximately 4%, even at absorption levels generally considered 'safe' (i.e. absorption <1). Thus careful consideration of instrumental spectral width, analyte concentration, and slope of molecular extinction coefficient is required to ensure robust analytical methods.

  20. A method for fast determination of psoralens in oral solutions of phytomedicines using liquid chromatography.

    PubMed

    Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima

    2004-10-29

    A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.

  1. Simultaneous determination of nicotine and cotinine in serum using high-performance liquid chromatography with fluorometric detection and postcolumn UV-photoirradiation system.

    PubMed

    Yasuda, Makoto; Ota, Tatsuhiro; Morikawa, Atsushi; Mawatari, Ken-ichi; Fukuuchi, Tomoko; Yamaoka, Noriko; Kaneko, Kiyoko; Nakagomi, Kazuya

    2013-09-01

    A simple and rapid method for the simultaneous determination of serum nicotine and cotinine using high-performance liquid chromatography (HPLC)-fluorometric detection with a postcolumn ultraviolet-photoirradiation system was developed. Analytes were extracted from alkalinized human serum via liquid-liquid extraction using chloroform. The organic phase was back-extracted with the acidified aqueous phase, and the analytes were directly injected into an ion-pair reversed-phase HPLC system. 6-Aminoquinoline was used as an internal standard. Nicotine, cotinine, and 6-aminoquinoline were separated within 14min. The extraction efficiency of nicotine and cotinine was greater than 91%. The linear range was 0.30-1000ng for nicotine and 0.06-1000ng for cotinine. In serum samples from smokers, the concentrations of nicotine and cotinine were 8-15ng/mL and 156-372ng/mL, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Hot conditioning equipment conceptual design report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradshaw, F.W., Westinghouse Hanford

    1996-08-06

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hotmore » Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.« less

  3. 14 CFR 61.68 - Category III pilot authorization requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... lighting system; (ix) Characteristics and limitations of the flight director system auto approach coupler (including split axis type if equipped), auto throttle system (if equipped), and other Category III equipment...

  4. An intelligent healthcare management system: a new approach in work-order prioritization for medical equipment maintenance requests.

    PubMed

    Hamdi, Naser; Oweis, Rami; Abu Zraiq, Hamzeh; Abu Sammour, Denis

    2012-04-01

    The effective maintenance management of medical technology influences the quality of care delivered and the profitability of healthcare facilities. Medical equipment maintenance in Jordan lacks an objective prioritization system; consequently, the system is not sensitive to the impact of equipment downtime on patient morbidity and mortality. The current work presents a novel software system (EQUIMEDCOMP) that is designed to achieve valuable improvements in the maintenance management of medical technology. This work-order prioritization model sorts medical maintenance requests by calculating a priority index for each request. Model performance was assessed by utilizing maintenance requests from several Jordanian hospitals. The system proved highly efficient in minimizing equipment downtime based on healthcare delivery capacity, and, consequently, patient outcome. Additionally, a preventive maintenance optimization module and an equipment quality control system are incorporated. The system is, therefore, expected to improve the reliability of medical equipment and significantly improve safety and cost-efficiency.

  5. Evaluation of multiple reaction monitoring cubed for the analysis of tachykinin related peptides in rat spinal cord using a hybrid triple quadrupole-linear ion trap mass spectrometer.

    PubMed

    Pailleux, Floriane; Beaudry, Francis

    2014-02-01

    Targeted peptide methods generally use HPLC-MS/MRM approaches. Although dependent on the instrumental resolution, interferences may occur while performing analysis of complex biological matrices. HPLC-MS/MRM(3) is a technique, which provides a significantly better selectivity, compared with HPLC-MS/MRM assay. HPLC-MS/MRM(3) allows the detection and quantitation by enriching standard MRM with secondary product ions that are generated within the linear ion trap. Substance P (SP) and neurokinin A (NKA) are tachykinin peptides playing a central role in pain transmission. The objective of this study was to verify whether HPLC-MS/MRM(3) could provide significant advantages over a more traditional HPLC-MS/MRM assay for the quantification of SP and NKA in rat spinal cord. The results suggest that reconstructed MRM(3) chromatograms display significant improvements with the nearly complete elimination of interfering peaks but the sensitivity (i.e. signal-to-noise ratio) was severely reduced. The precision (%CV) observed was between 3.5% and 24.1% using HPLC-MS/MRM and in the range of 4.3-13.1% with HPLC-MS/MRM(3), for SP and NKA. The observed accuracy was within 10% of the theoretical concentrations tested. HPLC-MS/MRM(3) may improve the assay sensitivity to detect difference between samples by reducing significantly the potential of interferences and therefore reduce instrumental errors. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Aircraft Enroute Command and Control Comms Redesign Mechanical Documentation

    DTIC Science & Technology

    2015-12-01

    and power equipment is secured. Custom racks , with 8 server rack bays, are mounted to the pallet, with 2 desk stations for equipment operators...conventional rack equipment. Equipment in the original system was larger and heavier than the new equipment selected for the NG-JC2S. Battery backup was...purposes. The equipment also needed to be easily removable in the event of equipment failure. Surplus rack space available in the NG-JC2S system allowed

  7. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    ERIC Educational Resources Information Center

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  8. Quantification of quercetin glycosides in 6 onion cultivars and comparisons of hydrolysis-HPLC and spectrophotometric methods in measuring total quercetin concentrations.

    PubMed

    Yoo, Kil Sun; Lee, Eun Jin; Patil, Bhimanagouda S

    2010-03-01

    This study was performed to purify and quantify quercetin glycosides (QG) and aglycone (free) quercetin (Q) in 6 selected onion cultivars and to compare analytical approaches based on high-performance liquid chromatography (HPLC) and spectrophotometry for the quantification of total quercetin (TQ) concentrations. Individual mono- and di-glycoside Q compounds were purified using a semipreparative HPLC and identified by comparing spectral data and by confirming corresponding peaks of QG and Q after incomplete enzyme-hydrolysis. Purified QG were quantified as Q by enzyme-hydrolysis/HPLC. TQ concentrations obtained from 20 onion bulbs with enzyme-hydrolysis/HPLC, no-hydrolysis/HPLC, and a spectrophotometric method without prior hydrolysis were significantly correlated (r(2)= 0.99) and were about 15% higher, identical, or 10% less than those concentrations by a standard acid-hydrolysis/HPLC method, respectively. During enzyme-hydrolysis of onion extracts, progressive reduction of the QG and formation of the corresponding mono-glycosides and Q were monitored using an analytical HPLC. TQ ranged from 83 to 330 microg/g F.W. in 6 selected cultivars of long-day or short-day onions. Q3,4'G and Q4'G were the 2 major compounds and comprised approximately between 94% and 97% of TQ in onions.

  9. Journal of Chemical Education: Software.

    ERIC Educational Resources Information Center

    Journal of Chemical Education, 1988

    1988-01-01

    Describes a chemistry software program that emulates a modern binary gradient HPLC system with reversed phase column behavior. Allows for solvent selection, adjustment of gradient program, column selection, detectory selection, handling of computer sample data, and sample preparation. (MVL)

  10. Isolation and purification of lutein from the microalga Chlorella vulgaris by extraction after saponification.

    PubMed

    Li, Hua-Bin; Jiang, Yue; Chen, Feng

    2002-02-27

    A simple and efficient method for the isolation and purification of lutein from the microalga Chlorella vulgaris was developed. Crude lutein was obtained by extraction with dichloromethane from the microalga after saponification. Partition values of lutein in the two-phase system of ethanol-water-dichloromethane at different ratios were measured by HPLC so as to assist the determination of an appropriate condition for washing water-soluble impurities in the crude lutein. Partition values of lutein in another two-phase system of ethanol-water-hexane at different ratios were also measured by HPLC for determining the condition for removing fat-soluble impurities. The water-soluble impurities in the crude lutein were removed by washing with 30% aqueous ethanol, and the fat-soluble impurities were removed by extraction with hexane. The final purity of lutein obtained was 90-98%, and the yield was 85-91%.

  11. Resonance light scattering determination of 6-mercaptopurine coupled with HPLC technique

    NASA Astrophysics Data System (ADS)

    Li, Ai Ping; Peng, Jing Dong; Zhou, MingQiong; Zhang, Jin

    2016-02-01

    A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH 5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λex = λem = 315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 μg L- 1 and the limit of detection (S/N = 3) was 0.05 μg L- 1. The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed.

  12. Resonance light scattering determination of 6-mercaptopurine coupled with HPLC technique.

    PubMed

    Li, Ai Ping; Peng, Jing Dong; Zhou, MingQiong; Zhang, Jin

    2016-02-05

    A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λ(ex)=λ(em)=315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 μg L(-1) and the limit of detection (S/N=3) was 0.05 μg L(-1). The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. 14 CFR 25.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1309... electrical system and equipment design and installation, critical environmental conditions must be considered. For electrical generation, distribution, and utilization equipment required by or used in complying...

  14. High-speed railway signal trackside equipment patrol inspection system

    NASA Astrophysics Data System (ADS)

    Wu, Nan

    2018-03-01

    High-speed railway signal trackside equipment patrol inspection system comprehensively applies TDI (time delay integration), high-speed and highly responsive CMOS architecture, low illumination photosensitive technique, image data compression technique, machine vision technique and so on, installed on high-speed railway inspection train, and achieves the collection, management and analysis of the images of signal trackside equipment appearance while the train is running. The system will automatically filter out the signal trackside equipment images from a large number of the background image, and identify of the equipment changes by comparing the original image data. Combining with ledger data and train location information, the system accurately locate the trackside equipment, conscientiously guiding maintenance.

  15. The use of capillary electrophoresis as part of a specificity testing strategy for mitoguazone dihydrochloride HPLC methods.

    PubMed

    Thomson, C E; Gray, M R; Baxter, M P

    1997-05-01

    Capillary electrophoresis (CE) has been used as part of a validation experiment designed to prove the specificity of high performance liquid chromatography (HPLC) methods used for analysis of mitoguazone dihydrochloride drug substance. Data regarding accuracy, precision and sensitivity of the CE methods are presented as well as a comparison of results obtained from CE, HPLC and thin-layer chromatography (TLC) analysis of samples stressed under a variety of conditions. It was concluded that, not only were the HPLC methods being investigated specific, but that CE could potentially be used to replace HPLC for the routine assay of mitoguazone dihydrochloride.

  16. 49 CFR 232.603 - Design, interoperability, and configuration management requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... requirements. (a) General. A freight car or freight train equipped with an ECP brake system shall, at a minimum...) Approval. A freight train or freight car equipped with an ECP brake system and equipment covered by the AAR...) Configuration management. A railroad operating a freight train or freight car equipped with ECP brake systems...

  17. 49 CFR 232.603 - Design, interoperability, and configuration management requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... requirements. (a) General. A freight car or freight train equipped with an ECP brake system shall, at a minimum...) Approval. A freight train or freight car equipped with an ECP brake system and equipment covered by the AAR...) Configuration management. A railroad operating a freight train or freight car equipped with ECP brake systems...

  18. 49 CFR 232.603 - Design, interoperability, and configuration management requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requirements. (a) General. A freight car or freight train equipped with an ECP brake system shall, at a minimum...) Approval. A freight train or freight car equipped with an ECP brake system and equipment covered by the AAR...) Configuration management. A railroad operating a freight train or freight car equipped with ECP brake systems...

  19. 49 CFR 232.603 - Design, interoperability, and configuration management requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... requirements. (a) General. A freight car or freight train equipped with an ECP brake system shall, at a minimum...) Approval. A freight train or freight car equipped with an ECP brake system and equipment covered by the AAR...) Configuration management. A railroad operating a freight train or freight car equipped with ECP brake systems...

  20. An evaluation of Skylab habitability hardware

    NASA Technical Reports Server (NTRS)

    Stokes, J.

    1974-01-01

    For effective mission performance, participants in space missions lasting 30-60 days or longer must be provided with hardware to accommodate their personal needs. Such habitability hardware was provided on Skylab. Equipment defined as habitability hardware was that equipment composing the food system, water system, sleep system, waste management system, personal hygiene system, trash management system, and entertainment equipment. Equipment not specifically defined as habitability hardware but which served that function were the Wardroom window, the exercise equipment, and the intercom system, which was occasionally used for private communications. All Skylab habitability hardware generally functioned as intended for the three missions, and most items could be considered as adequate concepts for future flights of similar duration. Specific components were criticized for their shortcomings.

  1. Comparative evaluation of an ISO 3632 method and an HPLC-DAD method for safranal quantity determination in saffron.

    PubMed

    García-Rodríguez, M Valle; López-Córcoles, Horacio; Alonso, Gonzalo L; Pappas, Christos S; Polissiou, Moschos G; Tarantilis, Petros A

    2017-04-15

    The aim of this work was a comparison of the ISO 3632 (2011) method and an HPLC-DAD method for safranal quantity determination in saffron. Samples from different origins were analysed by UV-vis according to ISO 3632 (2011) and by HPLC-DAD. Both methods were compared, and there was no correlation between the safranal content obtained by UV-vis and HPLC-DAD. An over-estimation in the UV-vis experiment was observed, which was related to the cis-crocetin esters content, as well as other compounds. The results demonstrated that there was no relationship between ISO quality categories and safranal content using HPLC-DAD. Therefore, HPLC-DAD might be preferable to UV-vis for determining the safranal content and the classification of saffron for commercial purposes. In addition, HPLC-DAD was adequate for determining the three foremost parameters that define the quality of saffron (crocetin esters, picrocrocin and safranal); therefore, this approach could be included in the ISO 3632 method (2011). Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Chemistry and liquid chromatography methods for the analyses of primary oxidation products of triacylglycerols.

    PubMed

    Zeb, A

    2015-05-01

    Triacylglycerols (TAGs) are one of the major components of the cells in higher biological systems, which can act as an energy reservoir in the living cells. The unsaturated fatty acid moiety is the key site of oxidation and formation of oxidation compounds. The TAG free radical generates several primary oxidation compounds. These include hydroperoxides, hydroxides, epidioxides, hydroperoxy epidioxides, hydroxyl epidioxides, and epoxides. The presence of these oxidized TAGs in the cell increases the chances of several detrimental processes. For this purpose, several liquid chromatography (LC) methods were reported in their analyses. This review is therefore focused on the chemistry, oxidation, extraction, and the LC methods reported in the analyses of oxidized TAGs. The studies on thin-layer chromatography were mostly focused on the total oxidized TAGs separation and employ hexane as major solvent. High-performance LC (HPLC) methods were discussed in details along with their merits and demerits. It was found that most of the HPLC methods employed isocratic elution with methanol and acetonitrile as major solvents with an ultraviolet detector. The coupling of HPLC with mass spectrometry (MS) highly increases the efficiency of analysis as well as enables reliable structural elucidation. The use of MS was found to be helpful in studying the oxidation chemistry of TAGs and needs to be extended to the complex biological systems.

  3. 36 CFR § 1194.4 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... description. Assistive technology. Any item, piece of equipment, or system, whether acquired commercially... equipment or interconnected system or subsystem of equipment, that is used in the creation, conversion, or... information. For example, HVAC (heating, ventilation, and air conditioning) equipment such as thermostats or...

  4. SAIDE: A Semi-Automated Interface for Hydrogen/Deuterium Exchange Mass Spectrometry.

    PubMed

    Villar, Maria T; Miller, Danny E; Fenton, Aron W; Artigues, Antonio

    2010-01-01

    Deuterium/hydrogen exchange in combination with mass spectrometry (DH MS) is a sensitive technique for detection of changes in protein conformation and dynamics. Since temperature, pH and timing control are the key elements for reliable and efficient measurement of hydrogen/deuterium content in proteins and peptides, we have developed a small, semiautomatic interface for deuterium exchange that interfaces the HPLC pumps with a mass spectrometer. This interface is relatively inexpensive to build, and provides efficient temperature and timing control in all stages of enzyme digestion, HPLC separation and mass analysis of the resulting peptides. We have tested this system with a series of standard tryptic peptides reconstituted in a solvent containing increasing concentration of deuterium. Our results demonstrate the use of this interface results in minimal loss of deuterium due to back exchange during HPLC desalting and separation. For peptides reconstituted in a buffer containing 100% deuterium, and assuming that all amide linkages have exchanged hydrogen with deuterium, the maximum loss of deuterium content is only 17% of the label, indicating the loss of only one deuterium molecule per peptide.

  5. SAIDE: A Semi-Automated Interface for Hydrogen/Deuterium Exchange Mass Spectrometry

    PubMed Central

    Villar, Maria T.; Miller, Danny E.; Fenton, Aron W.; Artigues, Antonio

    2011-01-01

    Deuterium/hydrogen exchange in combination with mass spectrometry (DH MS) is a sensitive technique for detection of changes in protein conformation and dynamics. Since temperature, pH and timing control are the key elements for reliable and efficient measurement of hydrogen/deuterium content in proteins and peptides, we have developed a small, semiautomatic interface for deuterium exchange that interfaces the HPLC pumps with a mass spectrometer. This interface is relatively inexpensive to build, and provides efficient temperature and timing control in all stages of enzyme digestion, HPLC separation and mass analysis of the resulting peptides. We have tested this system with a series of standard tryptic peptides reconstituted in a solvent containing increasing concentration of deuterium. Our results demonstrate the use of this interface results in minimal loss of deuterium due to back exchange during HPLC desalting and separation. For peptides reconstituted in a buffer containing 100% deuterium, and assuming that all amide linkages have exchanged hydrogen with deuterium, the maximum loss of deuterium content is only 17% of the label, indicating the loss of only one deuterium molecule per peptide. PMID:25309638

  6. Analysis of lipoprotein profiles of healthy cats by gel-permeation high-performance liquid chromatography

    PubMed Central

    MIZUTANI, Hisashi; SAKO, Toshinori; OKUDA, Hiroko; ARAI, Nobuaki; KURIYAMA, Koji; MORI, Akihiro; YOSHIMURA, Itaru; KOYAMA, Hidekazu

    2016-01-01

    Density gradient ultracentrifugation (DGUC) and gel electrophoresis are conventionally used to obtain lipoprotein profiles of animals. We recently applied high-performance liquid chromatography with a gel permeation column (GP-HPLC) and an on-line dual enzymatic system to dogs for lipoprotein profile analysis. We compared the GP-HPLC with DGUC as a method to obtain a feline lipoprotein profile. The lipoprotein profiles showed large and small peaks, which corresponded to high-density lipoprotein (HDL) and low-density lipoprotein (LDL), respectively, whereas very low-density lipoprotein (VLDL) and chylomicron (CM) were only marginally detected. This profile was very similar to that of dogs reported previously. Healthy cats also had a small amount of cholesterol-rich particles distinct from the normal LDL or HDL profile. There was no difference in lipoprotein profiles between the sexes, but males had a significantly larger LDL particle size (P=0.015). This study shows the feasibility of GP-HPLC for obtaining accurate lipoprotein profiles with small sample volumes and provides valuable reference data for healthy cats that should facilitate diagnoses. PMID:27170431

  7. Simultaneous Determination of Ursodeoxycholic Acid and Chenodeoxycholic Acid in Pharmaceutical Dosage Form by HPLC-UV Detection.

    PubMed

    Khairy, Mostafa A; Mansour, Fotouh R

    2017-01-01

    A reversed-phase HPLC method was developed for the simultaneous determination of ursodeoxycholic acid (UDCA) and the epimeric isomer, chenodeoxycholic acid (CDCA), in their synthetic mixtures and in tablet dosage form. The proposed HPLC method uses a C18 column and mobile phase consisting of an acetonitrile-phosphate buffer mixture (pH 2.3, 100 mM; 50 + 50, v/v) at a flow rate of 2.0 mL/min with UV detection at 210 nm. The method was validated according to the International Conference on Harmonization guidelines; and linearity, range, accuracy, precision, robustness, and system suitability were studied. The LOD and LOQ were also calculated and found to be 1.23 and 3.73 μg/mL for UDCA and 0.83 and 2.52 μg/mL for CDCA, respectively. The method was adapted for UHPLC, in which baseline separation was achieved in <2.5 min. The assay results of Ursomix tablets by the developed method were statistically compared with those obtained by the reference method using t- and F-tests, and no significant differences were observed.

  8. A single extraction and HPLC procedure for simultaneous analysis of phytosterols, tocopherols and lutein in soybeans.

    PubMed

    Slavin, Margaret; Yu, Liangli Lucy

    2012-12-15

    A saponification/extraction procedure and high performance liquid chromatography (HPLC) analysis method were developed and validated for simultaneous analysis of phytosterols, tocopherols and lutein (a carotenoid) in soybeans. Separation was achieved on a phenyl column with a ternary, isocratic solvent system of acetonitrile, methanol and water (48:22.5:29.5, v/v/v). Evaporative light scattering detection (ELSD) was used to quantify β-sitosterol, stigmasterol, campesterol, and α-, δ- and γ-tocopherols, while lutein was quantified with visible light absorption at 450 nm. Peak identification was verified by retention times and spikes with external standards. Standard curves were constructed (R(2)>0.99) to allow for sample quantification. Recovery of the saponification and extraction was demonstrated via analysis of spiked samples. Also, the accuracy of results of four soybeans using the described saponification and HPLC analytical method was validated against existing methods. This method offers a more efficient alternative to individual methods for quantifying lutein, tocopherols and sterols in soybeans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Preparative Isolation and Purification of Flavone C-Glycosides from the Leaves of Ficus microcarpa L. f by Medium-Pressure Liquid Chromatography, High-Speed Countercurrent Chromatography, and Preparative Liquid Chromatography

    PubMed Central

    Wang, Xiaohong; Liang, Yong; Zhu, Licai; Xie, Huichun; Li, Hang; He, Junting; Pan, Man; Zhang, Tianyou; Ito, Yoichiro

    2009-01-01

    Combined with medium-pressure liquid chromatography (MPLC) and preparative high-performance liquid chromatography (perp-HPLC), high-speed countercurrent chromatography (HSCCC) was applied for separation and purification of flavone C-glycosides from the crude extract of leaves of Ficus microcarpae L. f. HSCCC separation was performed on a two-phase solvent system composed of methyl tert- butyl ether - ethyl acetate – 1-butanol – acetonitrile – 0.1% aqueous trifluoroacetic acid at a volume ratio of 1:3:1:1:5. Partially resolved peak fractions from HSCCC separation were further purified by preparative HPLC. Four well-separated compounds were obtained and their purities were determined by HPLC. The purities of these peaks were 97.28%, 97.20%, 92.23%, and 98.40%.. These peaks were characterized by ESI-MSn. According to the reference, they were identified as orientin (peak I), isovitexin-3″-O-glucopyranoside (peak II), isovitexin (peak III), and vitexin (peak IV), yielded 1.2 mg, 4.5 mg, 3.3 mg, and 1.8 mg, respectively. PMID:20190866

  10. A method for the preparation of curcumin by ultrasonic-assisted ammonium sulfate/ethanol aqueous two phase extraction.

    PubMed

    Xu, Guangkuan; Hao, Changchun; Tian, Suyang; Gao, Feng; Sun, Wenyuan; Sun, Runguang

    2017-01-15

    This study investigated a new and easy-to-industrialized extracting method for curcumin from Curcuma longa rhizomes using ultrasonic extraction technology combined with ammonium sulfate/ethanol aqueous two-phase system (ATPS), and the preparation of curcumin using the semi-preparative HPLC. The single-factor experiments and response surface methodology (RSM) were utilized to determine the optimal material-solvent ratio, ultrasonic intensity (UI) and ultrasonic time. The optimum extraction conditions were finally determined to be material-solvent rate of 3.29:100, ultrasonic intensity of 33.63W/cm 2 and ultrasonic time of 17min. At these optimum conditions, the extraction yield could reach 46.91mg/g. And the extraction yields of curcumin remained stable in the case of amplification, which indicated that scale-up extraction was feasible and efficient. Afterwards, the semi-preparative HPLC experiment was carried out, in which optimal preparation conditions were elected according to the single factor experiment. The prepared curcumin was obtained and the purity could up to 85.58% by the semi-preparative HPLC. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Analysis of residual monomers in dendritic methacrylate copolymers and composites by HPLC and headspace-GC/MS.

    PubMed

    Viljanen, Eeva K; Langer, Sarka; Skrifvars, Mikael; Vallittu, Pekka K

    2006-09-01

    The aim of this study was to analyze the residual monomer content of photopolymerized dendritic methacrylate copolymers and particulate filler composites. Headspace-gas chromatography/mass spectrometry (HS-GC/MS) was compared with high performance liquid chromatography (HPLC). The resin mixtures consisted of a dendritic methacrylate monomer, methyl methacrylate and acetoacetoxyethyl methacrylate in varied proportions. In addition, one of the composites contained 1,4-butanediol dimethacrylate. Camphorquinone and 2-(N,N-dimethylamino)ethyl methacrylate were used as the light-activated initiator system. The content of residual methyl methacrylate and acetoacetoxyethyl methacrylate after 40 s photopolymerization were analyzed with HPLC and HS-GC/MS. The content of residual methyl methacrylate decreased and residual acetoacetoxyethyl methacrylate increased with increasing concentration of acetoacetoxyethyl methacrylate in the resin mixture. The results with both methods had the same trend. The addition of acetoacetoxyethyl methacrylate enhanced the copolymerization of methyl methacrylate, but did not decrease the total residual monomer content. The HS-GC/MS method was found to be a feasible method in the analysis of low-boiling residuals in dental polymers.

  12. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J; Kertesz, Vilmos; Gan, Jinping

    2016-03-25

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites were studied. Major organs (brain, lung, liver, kidney and muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. In addition, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Short communication: simultaneous analysis of reducing sugars and 5-hydroxymethyl-2-furaldehyde at a low concentration by high performance anion exchange chromatography with electrochemical detector, compared with HPLC with refractive index detector.

    PubMed

    Guan, Y-G; Yu, P; Yu, S-J; Xu, X-B; Wu, X-L

    2012-11-01

    A simultaneous analysis of reducing sugars and 5-hydroxymethyl-2-furaldehyde of the Maillard reaction products was detailed. It was based on a high performance anion exchange chromatography with electrochemical detector system and an HPLC with refractive index detector. Results showed that high performance anion exchange chromatography with electrochemical detector using a CarboPac PA-1 column (Dionex Corp., Sunnyvale, CA) was more suitable for reducing sugars and 5-hydroxymethyl-2-furaldehyde determination, especially for trace analysis. The lowest detectable limit of reducing sugars and 5-hydroxymethyl-2-furaldehyde was 0.00005 mol/L in this experiment. However, HPLC with a refractive index detector always produces a tailing peak for 5-hydroxymethyl-2-furaldehyde, and mannose and fructose cannot be absolutely separated. The results of the present study could provide a more sensitive means for 5-hydroxymethyl-2-furaldehyde and reducing sugar detection. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on-line solid-phase extraction technique.

    PubMed

    Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori

    2011-07-01

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Rapid purification of staphylococcal enterotoxin B by high-pressure liquid chromatography.

    PubMed Central

    Strickler, M P; Neill, R J; Stone, M J; Hunt, R E; Brinkley, W; Gemski, P

    1989-01-01

    The Staphylococcus aureus enterotoxins represent a group of proteins that cause emesis and diarrhea in humans and other primates. We have developed a rapid two-step high-pressure liquid chromatography (HPLC) procedure for purification of staphylococcal enterotoxin B (SEB). Sterile filtrates (2.5 liters) of strain 10-275 were adsorbed directly onto a reversed-phase column (50 mm by 30 cm Delta Pak; 300 A [30 nm], 15 microns, C18). SEB was obtained by using a unique sequential gradient system. First, an aqueous ammonium acetate to acetonitrile gradient followed by an aqueous trifluoroacetic acid (TFA) wash was used to remove contaminants. A subsequent TFA to acetonitrile-TFA gradient eluted the bound SEB. Further purification was obtained by rechromatography on a cation-exchange column. From 35 to 45% of the SEB in starting filtrates was recovered. Analysis by immunoblotting of samples separated on sodium dodecyl sulfate-polyacrylamide gels indicated that HPLC-purified SEB exhibited immunological and biochemical properties similar to those of the SEB standard. Induction of an emetic response in rhesus monkeys showed that the HPLC-purified toxin also retained biological activity. Images PMID:2745678

  16. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    DOE PAGES

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J.; ...

    2015-11-03

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed themore » same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.« less

  17. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J.

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed themore » same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.« less

  18. Measurement of Ether Phospholipids in Human Plasma with HPLC-ELSD and LC/ESI-MS After Hydrolysis of Plasma with Phospholipase A1.

    PubMed

    Mawatari, Shiro; Hazeyama, Seira; Fujino, Takehiko

    2016-08-01

    Ethanolamine ether phospholipid (eEtnGpl) and choline ether phospholipid (eChoGpl) are present in human plasma or serum, but the relative concentration of the ether phospholipids in plasma is very low as compared to those in other tissues. Nowadays, measurement of ether phospholipids in plasma depends on tandem mass spectrometry (LC/MS/MS), but a system for LC/MS/MS is generally too expensive for usual clinical laboratories. Treatment of plasma with phospholipase A1 (PLA1) causes complete hydrolysis of diacylphospholipids, but ether phospholipids remain intact. After the treatment of plasma with PLA1, both eEtnGpl and eChoGpl are detected as independent peaks by high-performance liquid chromatography with evaporative light scattering detection (HPLC-ELSD). The same sample used for HPLC-ELSD can be applied to detect eEtnGpl and eChoGpl with electrospray ionization mass spectrometry. Presence of alkylacylphospholipids in both eChoGpl and eEtnGpl in human plasma was indicated by sequential hydrolysis of plasma with PLA1 and hydrochloric acid.

  19. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.

    PubMed

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.

  20. [Various methods for the determination of preservatives in food. II. Gaschromatography, high performance liquid chromatography, TAS-method (author's transl)].

    PubMed

    Hild, J; Gertz, C

    1980-02-01

    For the quantitative determination of preservatives in food, analyses were carried out by means of GLC, HPLC, and TLC according to the TAS-method. Using the alkaline extract (sample preparation see part I) the preservatives can be analysed as free acid or appropriate ester out the same GLC-column without any interference from coextractives. A fast and accurate HPLC determination can be achieved by direct injection of the alkaline extract. All preservatives were well separated and detected at a wavelength of 225 resp. 232 nm. As a quick test for the qualitative estimation the TLC (TAS) method is suggested and a suitable solvent system is proposed.

  1. Immobilized enzyme reactors in HPLC and its application in inhibitor screening: A review

    PubMed Central

    Fang, Si-Meng; Wang, Hai-Na; Zhao, Zhong-Xi; Wang, Wei-Hong

    2011-01-01

    This paper sets out to summarize the literatures based on immobilized enzyme bio-chromatography and its application in inhibitors screening in the last decade. In order to screen enzyme inhibitors from a mass of compounds in preliminary screening, multi-pore materials with good biocompatibility are used for the supports of immobilizing enzymes, and then the immobilized enzyme reactor applied as the immobilized enzyme stationary phase in HPLC. Therefore, a technology platform of high throughput screening is gradually established to screen the enzyme inhibitors as new anti-tumor drugs. Here, we briefly summarize the selective methods of supports, immobilization techniques, co-immobilized enzymes system and the screening model. PMID:29403726

  2. 46 CFR 130.220 - Design of equipment for cooking and heating.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Design of equipment for cooking and heating. 130.220 Section 130.220 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Miscellaneous Equipment and Systems § 130.220 Design of equipment for cooking and heating....

  3. 46 CFR 130.220 - Design of equipment for cooking and heating.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Design of equipment for cooking and heating. 130.220 Section 130.220 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Miscellaneous Equipment and Systems § 130.220 Design of equipment for cooking and heating....

  4. 33 CFR 106.255 - Security systems and equipment maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maintained according to manufacturers' recommendations. (b) Security systems must be regularly tested in... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Security systems and equipment... Shelf (OCS) Facility Security Requirements § 106.255 Security systems and equipment maintenance. (a...

  5. 14 CFR 29.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... effects of lightning strikes on the rotorcraft must be considered. (Secs. 313(a), 601, 603, 604, and 605... Equipment, systems, and installations. (a) The equipment, systems, and installations whose functioning is... functions under any foreseeable operating condition. (b) The rotorcraft systems and associated components...

  6. 14 CFR 29.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... effects of lightning strikes on the rotorcraft must be considered. (Secs. 313(a), 601, 603, 604, and 605... Equipment, systems, and installations. (a) The equipment, systems, and installations whose functioning is... functions under any foreseeable operating condition. (b) The rotorcraft systems and associated components...

  7. 14 CFR 27.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... showing compliance with paragraph (a), (b), or (c) of this section, the effects of lightning strikes on..., systems, and installations. (a) The equipment, systems, and installations whose functioning is required by... under any foreseeable operating condition. (b) The equipment, systems, and installations of a...

  8. 14 CFR 27.1309 - Equipment, systems, and installations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... showing compliance with paragraph (a), (b), or (c) of this section, the effects of lightning strikes on..., systems, and installations. (a) The equipment, systems, and installations whose functioning is required by... under any foreseeable operating condition. (b) The equipment, systems, and installations of a...

  9. Does Uniformity of Topical Corticosteroid Ophthalmic Medications: Flourometholone Acetate 0.1 Suspension and Loteprednol Etabonate 0.5 gel

    DTIC Science & Technology

    2017-01-03

    chromatography ( HPLC ) with photodiode array detection at 240 nm. Results: Flarex® had a mean concentration of 93.7% of the declared concentration when shaken...59 60 Journal of Ocular Pharmacology and Therapeutics Charlton E Stevens Rockville, MD. Methanol, ( HPLC grade), was obtained from Sigma-Aldrich...ST. Louis, MO. HPLC analysis of fluorometholone acetate and loteprednol etabonate HPLC analysis of fluorometholone acetate and loteprednol

  10. Study of phenformin metabolism in rat liver microsomes by HPLC, CE and on-line HPLC-electrospray ionization mass spectrometry.

    PubMed

    Llambias, E B; Luo, J

    1996-01-01

    Methods for the analysis of phenformin and its metabolite by high-performance liquid chromatography (HPLC), capillary electrophoresis (CE) and high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESIMS) are developed. The effects of pH, buffer concentration and proportion of organic modifier on the retention of the compounds in HPLC have been studied. The optimum condition was used for the separation and identification of phenformin and its metabolite in microsomal metabolism by HPLC-ESIMS. A simple CE method is also described for the separation of these compounds. Optimum incubation conditions and cofactor requirements for the formation of 4-hydroxyphenformin by microsomal preparations of rat liver were determined. A linear response in the formation of product was found with increasing concentrations of protein and up to 15 min incubation. High concentrations of phenformin inhibited its metabolite formation, and K(m) was 4 microM.

  11. An Analysis for Capital Expenditure Decisions at a Naval Regional Medical Center.

    DTIC Science & Technology

    1981-12-01

    Service Equipment Review Committee 1. Portable defibrilator Computed tomographic scanner and cardioscope 2. ECG cart Automated blood cell counter 3. Gas...system sterilizer Gas system sterilizer 4. Automated blood cell Portable defibrilator and counter cardioscope 5. Computed tomographic ECG cart scanner...dictating and automated typing) systems. e. Filing equipment f. Automatic data processing equipment including data communications equipment. g

  12. 47 CFR 27.1164 - The cost-sharing formula.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... control equipment; engineering costs (design/path survey); installation; systems testing; FCC filing costs; site acquisition and civil works; zoning costs; training; disposal of old equipment; test equipment... a replacement system, such as equipment and engineering expenses. C may not exceed $250,000 per...

  13. Satellite services system analysis study. Volume 4: Service equipment concepts

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Payload deployment equipment is discussed, including payload separation, retention structures, the remote manipulator system, tilt tables, the payload installation and deployment aid, the handling and positioning aid, and spin tables. Close proximity retrieval, and on-orbit servicing equipment is discussed. Backup and contingency equipment is also discussed. Delivery and retrieval of high-energy payloads are considered. Earth return equipment, the aft flight deck, optional, and advanced equipment are also discussed.

  14. Automated system for definition of life-cycle resources of electromechanical equipment

    NASA Astrophysics Data System (ADS)

    Zhukovskiy, Y.; Koteleva, N.

    2017-02-01

    The frequency of maintenance of electromechanical equipment depends on the plant, which uses and runs this equipment. Very often the maintenance frequency is poorly correlated with the actual state of the electromechanical equipment. Furthermore, traditional methods of diagnosis sometimes cannot work without stopping the process (for example, for equipment located in hard to reach places) and so the maintenance costs are increased. This problem can be solved using the indirect methods of diagnosing of the electromechanical equipment. The indirect methods often use the parameters in the real time and seldom use the parameters of traditional diagnostic methods for determination of the resource of electromechanical equipment. This article is dedicated to developing the structure of a special automated control system. This system must use the big flow of the information about the direct and indirect parameters of the equipment state from plants from different areas of industry and factories which produce the electromechanical equipment.

  15. Two-dimensional preparative liquid chromatography system for preparative separation of minor amount components from complicated natural products.

    PubMed

    Qiu, Ying-Kun; Chen, Fang-Fang; Zhang, Ling-Ling; Yan, Xia; Chen, Lin; Fang, Mei-Juan; Wu, Zhen

    2014-04-11

    An on-line comprehensive two-dimensional preparative liquid chromatography system was developed for preparative separation of minor amount components from complicated natural products. Medium-pressure liquid chromatograph (MPLC) was applied as the first dimension and preparative HPLC as the second one, in conjunction with trapping column and makeup pump. The performance of the trapping column was evaluated, in terms of column size, dilution ratio and diameter-height ratio, as well as system pressure from the view of medium pressure liquid chromatograph. Satisfactory trapping efficiency can be achieved using a commercially available 15 mm × 30 mm i.d. ODS pre-column. The instrument operation and the performance of this MPLC×preparative HPLC system were illustrated by gram-scale isolation of crude macro-porous resin enriched water extract of Rheum hotaoense. Automated multi-step preparative separation of 25 compounds, whose structures were identified by MS, (1)H NMR and even by less-sensitive (13)C NMR, could be achieved in a short period of time using this system, exhibiting great advantages in analytical efficiency and sample treatment capacity compared with conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Convenient and Efficient Method for Quality Control Analysis of 18F-Fluorocholine: For a Small Scale GMP-based Radiopharmaceuticals Laboratory Set-up.

    PubMed

    Hassan, Hishar; Abu Bakar, Suharzelim; Halim, Khairul Najah Che A; Idris, Jaleezah; Nordin, Abdul Jalil

    2016-01-01

    Prostate cancer continues to be the most prevalent cancer in men in Malaysia. As time progresses, the prospect of PET imaging modality in diagnosis of prostate cancer is promising, with on-going improvement on novel tracers. Among all tracers, 18F-Fluorocholine is reported to be a reputable tracer and reliable diagnostic technique for prostate imaging. Nonetheless, only 18F-Fluorodeoxyglucose (18F-FDG) is available and used in most oncology cases in Malaysia. With a small scale GMP-based radiopharmaceuticals laboratory set-up, initial efforts have been taken to put Malaysia on 18F-Fluorocholine map. This article presents a convenient, efficient and reliable method for quality control analysis of 18F-Fluorocholine. Besides, the aim of this research work is to assist local GMP radiopharmaceuticals laboratories and local authority in Malaysia for quality control analysis of 18F-Fluorocholine guideline. In this study, prior to synthesis, quality control analysis method for 18F-Fluorocholine was developed and validated, by adapting the equipment set-up used in 18F-Fluorodeoxyglucose (18FFDG) routine production. Quality control on the 18F-Fluorocholine was performed by means of pH, radionuclidic identity, radio-high performance liquid chromatography equipped with ultraviolet, radio- thin layer chromatography, gas chromatography and filter integrity test. Post-synthesis; the pH of 18F-Fluorocholine was 6.42 ± 0.04, with half-life of 109.5 minutes (n = 12). The radiochemical purity was consistently higher than 99%, both in radio-high performance liquid chromatography equipped with ultraviolet (r-HPLC; SCX column, 0.25 M NaH2PO4: acetonitrile) and radio-thin layer chromatography method (r-TLC). The calculated relative retention time (RRT) in r-HPLC was 1.02, whereas the retention factor (Rf) in r-TLC was 0.64. Potential impurities from 18F-Fluorocholine synthesis such as ethanol, acetonitrile, dimethylethanolamine and dibromomethane were determined in gas chromatography. Using our parameters, (capillary column: DB-200, 30 m x 0.53 mm x 1 um) and oven temperature of 35°C (isothermal), all compounds were well resolved and eluted within 3 minutes. Level of ethanol and acetonitrile in 18F-Fluorocholine were detected below threshold limit; less than 5 mg/ml and 0.41 mg/ml respectively. Meanwhile, dimethylethanolamine and dibromomethane were undetectable. A convenient, efficient and reliable quality control analysis work-up procedure for 18FFluorocholine has been established and validated to comply all the release criteria. The convenient method of quality control analysis may provide a guideline to local GMP radiopharmaceutical laboratories to start producing 18F-Fluorocholine as a tracer for prostate cancer imaging.

  17. Simultaneous Determination of Ten Constituents in Chaiqin Qingning Capsule by High-performance Liquid Chromatography Coupled with Triple-quadrupole Mass Spectrometry.

    PubMed

    Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu

    2017-01-01

    Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC-MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity.

  18. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with the pressurized liquid extraction for the quantification and confirmation of sulfonamides in the foods of animal origin.

    PubMed

    Yu, Huan; Tao, Yanfei; Chen, Dongmei; Wang, Yulian; Huang, Lingli; Peng, Dapeng; Dai, Menghong; Liu, Zhenli; Wang, Xu; Yuan, Zonghui

    2011-09-01

    The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group; determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.

  20. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  1. Study on Earthquake Response of High Voltage Electrical Equipment Coupling System with Flexible Busbar

    NASA Astrophysics Data System (ADS)

    Liu, Chuncheng; Qu, Da; Wang, Chongyang; Lv, Chunlei; Li, Guoqiang

    2017-12-01

    With the rapid development of technology and society, all walks of life in China are becoming more and more dependent on power systems. When earthquake occurs, the electrical equipment of substation is prone to damage because of its own structural features, top-heavy, and brittleness of main body. At the same time, due to the complex coupling of the soft electrical connection of substation electrical equipment, the negative impact can not be estimated. In this paper, the finite element model of the coupling system of the single unit of high voltage electrical equipment with the connecting soft bus is established and the seismic response is analysed. The results showed that there is a significant difference between the simple analysis for the seismic response of electrical equipment monomer and the analytical results of electrical equipment systems, and the impact on different electrical equipment is different. It lays a foundation for the future development of seismic performance analysis of extra high voltage electrical equipment.

  2. 78 FR 25840 - Installed Systems and Equipment for Use by the Flightcrew

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ... certified aircraft (examples include updating avionics systems, engines, drag reduction, interior... aircraft systems, equipment, and the aircraft itself, so that they understand the situation better. Active...-1175; Amdt. No. 25-138] RIN 2120-AJ83 Installed Systems and Equipment for Use by the Flightcrew AGENCY...

  3. Satellite services system analysis study: Propellant transfer system

    NASA Technical Reports Server (NTRS)

    1982-01-01

    General servicing requirements, a servicing mission concept and scenario, overall servicing needs, basic servicing equipment, and a general servicing mission configuration layout are addressed. Servicing needs, equipment concepts, system requirements equipment specifications, preliminary designs, and resource requirements for flight hardware for the propellant transfer system are also addressed.

  4. Determination of thiopurine S-methyltransferase activity by hydrophilic interaction liquid chromatography hyphenated with mass spectrometry.

    PubMed

    Pecher, Daniel; Dokupilová, Svetlana; Zelinková, Zuzana; Peppelenbosch, Maikel; Mikušová, Veronika; Mikuš, Peter

    2017-08-05

    Thiopurine S-methyltransferase (TPMT) plays an important role in the metabolism of thiopurines used in the therapy of inflammatory bowel diseases (IBD). In this work a new progressive method for the determination of TPMT activity in red blood cells lysates was developed. Analysis was carried out by means of hydrophilic interaction liquid chromatography (HILIC) hyphenated with mass spectrometry (MS). In comparison with reversed-phase high-performance liquid chromatography (RP-HPLC), that has been typically applied in determination of TPMT activity, the HILIC significantly improved the analytical signal provided by MS, shortened analysis time, and improved chromatographic resolution. The HILIC-HPLC-MS method was optimized and validated, providing favorable parameters of detection and quantitation limits (5.5 and 16.5pmol/mL, respectively), linearity (coefficient of determination 0.9999 in the range of 0.01-1.0nmol/mL), recovery and precision (93.25-100.37% with RSD 1.06-1.32% in the whole concentration range of QC samples). Moreover, in contrast to the conventional RP-HPLC-UV approach, the complex phenotype TPMT profiles can be reliably and without interferences monitored using the HILIC-HPLC-MS method. Such advanced monitoring can provide valuable detail information on the thiopurines (e.g. evaluating ratio of methylated and non-methylated 6-mercaptopurine) and, by that, TPMT action in biological systems before and during the therapy of IBD. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Estimation of color of durum wheat. Comparison of WSB, HPLC, and reflectance colorimeter measurements.

    PubMed

    Fratianni, Alessandra; Irano, Mario; Panfili, Gianfranco; Acquistucci, Rita

    2005-04-06

    Color is an important parameter involved in the definition of semolina and pasta quality. This character is mainly due to natural pigments (carotenoids) that are present at different levels in cereals and cereal products, due to botanical origin, growing conditions, distribution in the kernel, and technological processes. In food industries, color measurements are usually performed by means of automatic instruments that are rapid and safe, as alternatives to the chemical extraction methods. In this study, automatic measurements (CIE, color-space system L, a, b), water-saturated butanol (WSB), and HPLC determinations have been applied to evaluate the carotenoid content in whole meals and respective semolina samples produced from wheat cultivated in the years 2001 and 2002. In whole meals, total carotenoids, determined by HPLC, were about 3.0 microg/g (2001) and 3.5 microg/g (2002) calculated on dry weight (dw) and about 3.0 and 3.2 microg/g dw in corresponding semolina samples. The b values for the same period were 19.78 and 15.75, respectively, in raw materials and 20.03-21.67 in semolina. Results have confirmed lutein and beta-carotene as the main components mainly responsible for the yellow color in wheat grains. The ability of the index b to express natural dyeing was dependent on sample characteristics as demonstrated by the relationships found between this index and pigments, although the best correlation resulted between HPLC and WSB.

  6. Is high pressure liquid chromatography an effective screening tool for characterization of molecular defects in hemoglobinopathies?

    PubMed

    Moorchung, Nikhil; Phillip, Joseph; Sarkar, Ravi Shankar; Prasad, Rupesh; Dutta, Vibha

    2013-01-01

    Hemoglobinopathies constitute entities that are generated by either abnormal hemoglobin or thalassemias. high pressure liquid chromatography (HPLC) is one of the best methods for screening and detection of various hemoglobinopathies but it has intrinsic interpretive problems. The study was designed to evaluate the different mutations seen in cases of hemoglobinopathies and compare the same with screening tests. 68 patients of hemoglobinopathies were screened by HPLC. Mutation studies in the beta globin gene was performed using the polymerase chain reaction (PCR)-based allele-specific Amplification Refractory Mutation System (ARMS). Molecular analysis for the sickle cell mutation was done by standard methods. The IVS 1/5 mutation was the commonest mutation seen and it was seen in 26 (38.23%) of the cases. This was followed by the IVS 1/1, codon 41/42, codon 8/9, del 22 mutation, codon 15 mutation and the -619 bp deletion. No mutation was seen in eight cases. There was a 100% concordance between the sickle cell trait as diagnosed by HPLC and genetic testing. Our study underlies the importance of molecular testing in all cases of hemoglobinopathies. Although HPLC is a useful screening tool, molecular testing is very useful in accurately diagnosing the mutations. Molecular testing is especially applicable in cases with an abnormal hemoglobin (HbD, HbE and HbS) because there may be a concomitant inheritance of a beta thalassemia mutation. Molecular testing is the gold standard when it comes to the diagnosis of hemoglobinopathies.

  7. Mammalian Toxicology Testing: Problem Definition Study, Global Army Toxicology Requirements.

    DTIC Science & Technology

    1981-03-01

    Electronic Warfare Equipment (D251) Tactical ECK System (64750A) Protective Electronic Warfare Equipment (D540) High Energy Electromagnetic Radiation...Fighting Portable Weapon (for IFV) Smoke Grenade Launcher Staff Smart, Target-Activated Fire-and-Forget Tactical ECK System (63755A) Protective Electronic...Warfare Equipment (D251) Tactical ECK System (64750A) Protective Electronic Warfare Equipment (D540) High Energy Electromagnetic Radiation Weapons (e.g

  8. Emergency sacrificial sealing method in filters, equipment, or systems

    DOEpatents

    Brown, Erik P

    2014-09-30

    A system seals a filter or equipment component to a base and will continue to seal the filter or equipment component to the base in the event of hot air or fire. The system includes a first sealing material between the filter or equipment component and the base; and a second sealing material between the filter or equipment component and the base and proximate the first sealing material. The first sealing material and the second seal material are positioned relative to each other and relative to the filter or equipment component and the base to seal the filter or equipment component to the base and upon the event of fire the second sealing material will be activated and expand to continue to seal the filter or equipment component to the base in the event of hot air or fire.

  9. Characterisation of a major phytoplankton bloom in the River Thames (UK) using flow cytometry and high performance liquid chromatography.

    PubMed

    Moorhouse, H L; Read, D S; McGowan, S; Wagner, M; Roberts, C; Armstrong, L K; Nicholls, D J E; Wickham, H D; Hutchins, M G; Bowes, M J

    2018-05-15

    Recent river studies have observed rapid phytoplankton dynamics, driven by diurnal cycling and short-term responses to storm events, highlighting the need to adopt new high-frequency characterisation methods to understand these complex ecological systems. This study utilised two such analytical methods; pigment analysis by high performance liquid chromatography (HPLC) and cell counting by flow cytometry (FCM), alongside traditional chlorophyll spectrophotometry and light microscopy screening, to characterise the major phytoplankton bloom of 2015 in the River Thames, UK. All analytical techniques observed a rapid increase in chlorophyll a concentration and cell abundances from March to early June, caused primarily by a diatom bloom. Light microscopy identified a shift from pennate to centric diatoms during this period. The initial diatom bloom coincided with increased HPLC peridinin concentrations, indicating the presence of dinoflagellates which were likely to be consuming the diatom population. The diatom bloom declined rapidly in early June, coinciding with a storm event. There were low chlorophyll a concentrations (by both HPLC and spectrophotometric methods) throughout July and August, implying low biomass and phytoplankton activity. However, FCM revealed high abundances of pico-chlorophytes and cyanobacteria through July and August, showing that phytoplankton communities remain active and abundant throughout the summer period. In combination, these techniques are able to simultaneously characterise a wider range of phytoplankton groups, with greater certainty, and provide improved understanding of phytoplankton functioning (e.g. production of UV inhibiting pigments by cyanobacteria in response to high light levels) and ecological status (through examination of pigment degradation products). Combined HPLC and FCM analyses offer rapid and cost-effective characterisation of phytoplankton communities at appropriate timescales. This will allow a more-targeted use of light microscopy to capture phytoplankton peaks or to investigate periods of rapid community succession. This will lead to greater system understanding of phytoplankton succession in response to biogeochemical drivers. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  10. Determination and validation of six sunscreen agents in suncare products by UPLC and HPLC.

    PubMed

    Lee, So-Mi; Jeong, Hye-Jin; Chang, Ih Seop

    2008-01-01

    Methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine are sunscreen agents that have hydrophobic behaviors in common. They were not normally assayed with the following four sunscreen agents that have hydrophilic behaviors in a single chromatographic run: ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. For that reason, methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine require much time in order to assay products with those materials. A rapid, selective, and reproducible determination method needs to be developed for the simultaneous examination of methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine with the sunscreen agents, ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. This new technique could reduce time in examining the sunscreen agents and be effective for quality control of suncare products. In this paper, the HPLC and UPLC system is used for developing the determination of the sunscreen agents. Several evaluations of some mixtures of eluents and columns were obtained for the optimal condition of separation. In HPLC, the optimal peak resolution was obtained through ethanol-water gradient elution and a 75-mm C18 column with a 3.5-microm-sized particle on a flow rate of 1.0 ml/min. In UPLC, the most distinctive peak resolution was obtained through methanol-water gradient elution and a 50-mm C18 column with a 1.7-microm-sized particle on a flow rate 0.4 ml/min. Both of those chromatographic determination methods could be used in the examination of six types of sunscreen agents without any interference from other product excipients in the agents. The proposed determination methods were validated for specificity, linearity, repeatability, system stability, intermediate precision, and accuracy. Consequently, HPLC and UPLC determination methods could be rapid, selective, and proper applications for the assay of sunscreen agents in suncare products.

  11. Achiral-chiral two-dimensional chromatography of free amino acids in milk: A promising tool for detecting different levels of mastitis in cows.

    PubMed

    Ianni, Federica; Sardella, Roccaldo; Lisanti, Antonella; Gioiello, Antimo; Cenci Goga, Beniamino Terzo; Lindner, Wolfgang; Natalini, Benedetto

    2015-12-10

    In two-dimensional HPLC (2D-HPLC) "heart-cut" applications, two columns are connected in series via a switching valve and volume fractions from the "primary" column are re-injected on the "secondary" column. The heart-cut 2D-HPLC system here described was implemented by connecting a reversed-phase (RP) column (first dimension) to a chiral column (second dimension) containing a quinidine-based chiral stationary phase. The system was used to evaluate the change in the enantiomeric excess value of dansylated (Dns) amino acids (AAs) in milk samples from two cows with different "California Mastitis Test" scores: negative test for sample 1, positive for sample 2. Apart from the co-elution of Dns-Arg/Dns-Gly and the reduced chemoselectivity for Dns-Leu/Dns-allo-Ile, the optimized achiral RP method distinguished the remaining standard Dns-AAs. Dns-AAs were identified in the chromatograms of the real samples, and in higher concentration Dns-Ala, Dns-Arg, Dns-Asp, Dns-Glu, Dns-Ile, Dns-Leu, Dns-Phe and Dns-Val. Except Dns-Arg, the chiral column enabled the RP enantioseparation of all the other compounds (α and RS values up to 1.65 and 8.63, respectively, for Dns-Phe). In sample 2, the amounts of Dns-d-AAs were rather elevated, in particular for Dns-Ala and Dns-Asp. Instead, for sample 1, D-isomers were detected for Dns-Ala, Dns-Glu and Dns-Leu. The proposed 2D-HPLC method could be useful for the identification of clinical mastitis difficult to be diagnosed. Moreover, the eventual progressive reduction of D-AAs levels with the degree of sub-clinical mastitis could allow the building of mathematical models to use for the diagnosis of early stages of mastitis. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Rapid analysis of 2,4-D in soil samples by modified Soxhlet apparatus using HPLC with UV detection.

    PubMed

    Kashyap, Sanjay M; Pandya, Girish H; Kondawar, Vivek K; Gabhane, Sanjay S

    2005-02-01

    The 2,4-dichlorophenoxy acetic acid (2,4-D) is used as a systemic herbicide to control broadleaf weeds in wheat, corn, range land/pasture land, sorghum, and barley. In this study, a fast and efficient method is developed by selection of modified extraction apparatus and high-performance liquid chromatography (HPLC)-UV conditions for the determination of 2,4-D in soil samples. The method is applied to the study of soil samples collected from the agricultural field. The herbicide is extracted from soil samples by acetonitrile in a modified Soxhlet apparatus. The advantages of the apparatus are that it uses small volume of organic solvent, reduced time of extraction, and better recovery of the analyte. The extract is filtered using a very fine microfiber paper. The total extract is concentrated in a rotatory evaporator, dried under ultrahigh pure N2, and finally reconstituted in 1 mL of acetonitrile. HPLC-UV at 228 nm is used for analysis. The herbicide is identified and quantitated using the HPLC system. The method is validated by the analysis of spiked soil samples. Recoveries obtained varied from 85% to 100% for spiked soil samples. The limit of quantitation (LOQ) and the limit of detection (LOD) are 0.010 and 0.005 parts per million (ppm), respectively, for spiked soil samples. The LOQ and LOD are 0.006 and 0.003 ppm for unspiked soil samples. The measured concentrations of 2,4-D in spiked soil samples are between 0.010 and 0.020 ppm with an average of 0.016 +/- 0.003 ppm. For unspiked soil samples it is between 0.006 ppm and 0.012 ppm with an average of 0.009 +/- 0.002 ppm. The measured concentrations of 2,4-D in soil samples are generally low and do not exceed the regulatory agencies guidelines.

  13. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    PubMed

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  14. Information technology equipment cooling system

    DOEpatents

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  15. High-pressure liquid chromatography analysis of antibiotic susceptibility disks.

    PubMed Central

    Hagel, R B; Waysek, E H; Cort, W M

    1979-01-01

    The analysis of antibiotic susceptibility disks by high-pressure liquid chromatography (HPLC) was investigated. Methods are presented for the potency determination of mecillinam, ampicillin, carbenicillin, and cephalothin alone and in various combinations. Good agreement between HPLC and microbiological data is observed for potency determinations with recoveries of greater than 95%. Relative standard deviations of lower than 2% are recorded for each HPLC method. HPLC methods offer improved accuracy and greater precision when compared to the standard microbiological methods of analysis for susceptibility disks. PMID:507793

  16. Tri-Service Construction Guide Specifications

    DTIC Science & Technology

    1992-04-01

    Equipment 11474 NN 9102 11757 Radiographic Darkroom Equipment 11476 VA 8202 11471 Revolving Darkroom Doors 11494 VA 8201 11491 Hydrotherapy Equipment...11494 NN 9102 11716 Hydrotherapy Equipment 11500 CE 9105 11500 Air Pollution Control 11500 NS 9103 13255 Cleaning for Process Piping Systems 11600 NN...Doors (11471) 4 11494 - Hydrotherapy Equipment (11491) 0 0 11500 - Air Pollution Control 0 11500 - Cleaning for Process Piping Systems (13255) 0 11600

  17. 49 CFR 179.20 - Service equipment; protection systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Service equipment; protection systems. 179.20 Section 179.20 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... CARS General Design Requirements § 179.20 Service equipment; protection systems. If an applicable tank...

  18. User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations

    DTIC Science & Technology

    2017-08-01

    ARL-TN-0839 ● AUG 2017 US Army Research Laboratory User Guide: How to Use and Operate Virtual Reality Equipment in the Systems...ARL-TN-0839 ● AUG 2017 US Army Research Laboratory User Guide: How to Use and Operate Virtual Reality Equipment in the Systems...September 2017 4. TITLE AND SUBTITLE User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory

  19. 46 CFR 133.45 - Tests and inspections of lifesaving equipment and arrangements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... evacuation systems; (7) The ability of the crew to effectively carry out abandon-ship procedures; and (8) The... SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.45 Tests and inspections of lifesaving equipment and..., buoyant apparatus, and associated equipment; (4) The proper condition of distress signaling equipment...

  20. 46 CFR 113.10-1 - Approved equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...

  1. 46 CFR 113.10-1 - Approved equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...

  2. 46 CFR 113.10-1 - Approved equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...

  3. 46 CFR 113.10-1 - Approved equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...

  4. 46 CFR 113.10-1 - Approved equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Approved equipment. 113.10-1 Section 113.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-1 Approved equipment. Each alarm...

  5. 46 CFR 133.45 - Tests and inspections of lifesaving equipment and arrangements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... evacuation systems; (7) The ability of the crew to effectively carry out abandon-ship procedures; and (8) The... SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.45 Tests and inspections of lifesaving equipment and..., buoyant apparatus, and associated equipment; (4) The proper condition of distress signaling equipment...

  6. Fingerprint of Hedyotis diffusa Willd. by HPLC-MS.

    PubMed

    Yang, Ting; Yang, Yi-Hua; Yang, Ju-Yun; Chen, Ben-Mei; Duan, Ju-Ping; Yu, Shu-Yi; Ouyang, Hong-Tao; Cheng, Jun-Ping; Chen, Yu-Xiang

    2008-01-01

    A HPLC-MS fingerprint method has been developed based on the consistent chromatographic features of the major chemical constituents among 10 batches of Hedyotis diffusa Willd. Chromatographic separation was conducted on a Hypersil-Keystone Hypurity C(18) column using methanol:water:acetic acid as the mobile phase. Major compounds, including oleanolic acid, ursolic acid and ferulic acid, were analysed by HPLC-MS. Their analysis was ascertained by comparison with data derived from the standard compounds. The HPLC-MS fingerprint was successfully applied to analyse and differentiate samples from different geographical origins, or processing methods. H. diffusa was well distinguished from Hedyotis chrysotricha by HPLC-MS. Therefore the establishment of fingerprint of H. diffusa is critical in assessing and controlling its overall quality.

  7. Satellite services system analysis study. Volume 5: Programmatics

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The overall program and resources needed for development and operation of a Satellite Services System is reviewed. Program requirements covered system operations through 1993 and were completed in preliminary form. Program requirements were refined based on equipment preliminary design and analysis. Schedules, costs, equipment utilization, and facility/advanced technology requirements were included in the update. Equipment user charges were developed for each piece of equipment and for representative satellite servicing missions.

  8. Data center cooling system

    DOEpatents

    Chainer, Timothy J; Dang, Hien P; Parida, Pritish R; Schultz, Mark D; Sharma, Arun

    2015-03-17

    A data center cooling system may include heat transfer equipment to cool a liquid coolant without vapor compression refrigeration, and the liquid coolant is used on a liquid cooled information technology equipment rack housed in the data center. The system may also include a controller-apparatus to regulate the liquid coolant flow to the liquid cooled information technology equipment rack through a range of liquid coolant flow values based upon information technology equipment temperature thresholds.

  9. High-performance liquid chromatography of methanol released from pectins after its oxidation to formaldehyde and condensation with 2,4-dinitrophenylhydrazine.

    PubMed

    Zegota, H

    1999-11-26

    A procedure was developed to measure the content of methanol in pectins after the base-catalysed hydrolysis of galacturonic acid methyl esters and oxidation of released methanol with potassium permanganate followed by condensation of the resulting formaldehyde (HCHO) with 2,4-dinitrophenylhydrazine (DNPH) dissolved in acetonitrile. The constant yields of resultant formaldehyde 2,4-dinitrophenylhydrazone (HCHO-DNPH derivative) were obtained at molar ratios of DNPH/HCHO higher than 5. The separation of the HCHO-DNPH derivative from DNPH reagent was achieved by isocratic reversed-phase HPLC equipped with the spectrophotometric detector set at a wavelength of 351 nm. The calibration curve was linear in the methanol concentration range between 0.04 and 15 micromol/ml (R=0.9995). The total recovery from pectin solutions spiked with methanol was equal to 100.6+/-5.1%.

  10. Ultrasound-assisted analyte extraction for the determination of sulfate and elemental sulfur in zinc sulfide by different liquid chromatography techniques.

    PubMed

    Dash, K; Thangavel, S; Krishnamurthy, N V; Rao, S V; Karunasagar, D; Arunachalam, J

    2005-04-01

    The speciation and determination of sulfate (SO4(2-)) and elemental sulfur (S degree) in zinc sulfide (ZnS) using ion-chromatography (IC) and reversed-phase liquid chromatography (RPLC) respectively is described. Three sample pretreatment approaches were employed with the aim of determining sulfate: (i) conventional water extraction of the analyte; (ii) solid-liquid aqueous extraction with an ultrasonic probe; and (iii) elimination of the zinc sulfide matrix via ion-exchange dissolution (IED). The separation of sulfate was carried out by an anion-exchange column (IonPac AS17), followed by suppressed conductivity detection. Elemental sulfur was extracted ultrasonically from the acid treated sample solution into chloroform and separated on a reversed phase HPLC column equipped with a diode array detector (DAD) at 264 nm. The achievable solid detection limits for sulfate and sulfur were 35 and 10 microg g(-1) respectively.

  11. Development of NIRS method for quality control of drug combination artesunate–azithromycin for the treatment of severe malaria

    PubMed Central

    Boyer, Chantal; Gaudin, Karen; Kauss, Tina; Gaubert, Alexandra; Boudis, Abdelhakim; Verschelden, Justine; Franc, Mickaël; Roussille, Julie; Boucher, Jacques; Olliaro, Piero; White, Nicholas J.; Millet, Pascal; Dubost, Jean-Pierre

    2012-01-01

    Near infrared spectroscopy (NIRS) methods were developed for the determination of analytical content of an antimalarial-antibiotic (artesunate and azithromycin) co-formulation in hard gelatin capsule (HGC). The NIRS consists of pre-processing treatment of spectra (raw spectra and first-derivation of two spectral zones), a unique principal component analysis model to ensure the specificity and then two partial least-squares regression models for the determination content of each active pharmaceutical ingredient. The NIRS methods were developed and validated with no reference method, since the manufacturing process of HGC is basically mixed excipients with active pharmaceutical ingredients. The accuracy profiles showed β-expectation tolerance limits within the acceptance limits (±5%). The analytical control approach performed by reversed phase (HPLC) required two different methods involving two different preparation and chromatographic methods. NIRS offers advantages in terms of lower costs of equipment and procedures, time saving, environmentally friendly. PMID:22579599

  12. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    PubMed

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. 78 FR 19541 - Proposed Revision to Design of Structures, Components, Equipment and Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-01

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0041] Proposed Revision to Design of Structures, Components, Equipment and Systems AGENCY: Nuclear Regulatory Commission. ACTION: Standard review plan-draft..., ``Design of Structures, Components, Equipment, and Systems;'' and the request for comment on NUREG-0800...

  14. 46 CFR 169.253 - Miscellaneous systems and equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Miscellaneous systems and equipment. 169.253 Section 169.253 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Inspection and Certification Inspections § 169.253 Miscellaneous systems and equipment. (a) At...

  15. 46 CFR 169.253 - Miscellaneous systems and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Miscellaneous systems and equipment. 169.253 Section 169.253 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Inspection and Certification Inspections § 169.253 Miscellaneous systems and equipment. (a) At...

  16. Emergency sacrificial sealing method in filters, equipment, or systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Erik P.

    A system seals a filter or equipment component to abase and will continue to seal the filter or equipment component to the base in the event of hot air or fire. The system includes a first sealing material between the filter or equipment component and the base; and a second sealing material between the filter or equipment component and the base and proximate the first sealing material. The first sealing material and the second seal material are positioned relative to each other and relative to the filter or equipment component and the base to seal the filter or equipment componentmore » to the base and upon the event of fire the second sealing material will be activated and expand to continue to seal the filter or equipment component to the base in the event of hot air or fire.« less

  17. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Yu, Kate; Little, David; Plumb, Rob; Smith, Brian

    2006-01-01

    A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.

  18. Evaluation of a novel semi-automated HPLC procedure for whole blood cyclosporin A confirms equivalence to adjusted monoclonal values from Abbott TDx.

    PubMed

    Roberts, Norman B; Dutton, John; Higgins, Gerald; Allars, Lesley

    2005-01-01

    The problem in the measurement of cyclosporin (CyA) is that the widely used immuno-based assays suffer from interference by metabolites present in unpredictable excess. To resolve this, the consensus view has been to develop more specific and robust procedures for the measurement of CyA alone in order to give values similar to those obtained by HPLC. We developed an alternative strategy based on Abbott poly- and monoclonal assays to derive an adjusted monoclonal value as an equivalent measurement to HPLC. We have now evaluated a recently developed semi-automated HPLC procedure and used it to test the validity of the adjusted monoclonal value. The automated HPLC procedure with online clean-up was optimised for the separation of CyA and internal standard CyD. The assay was simple to use, precise and gave good recovery of cyclosporin from whole blood. Comparisons with the more specific immunoassays Abbott AxSym and EMIT showed close agreement, whereas Abbott monoclonal values indicated up to 20% positive bias. In contrast, the adjusted monoclonal values gave good agreement with HPLC. Data obtained from HPLC linked to tandem mass spectrometry (MS) indicated closer agreement with Abbott monoclonal values than expected, suggesting some positive bias with MS. The benefit of using an adjusted monoclonal value is that a result equivalent to HPLC is obtained, as well as an indication of the concentration of metabolites from the Abbott polyclonal measurement.

  19. The effect of re-dissolution solvents and HPLC columns on the analysis of mycosporine-like amino acids in the eulittoral macroalgae Prasiola crispa and Porphyra umbilicalis

    NASA Astrophysics Data System (ADS)

    Karsten, Ulf; Escoubeyrou, Karine; Charles, François

    2009-09-01

    Many macroalgal species that are regularly exposed to high solar radiation such as the eulittoral green alga Prasiola crispa and the red alga Porphyra umbilicalis synthesize and accumulate high concentrations of mycosporine-like amino acids (MAAs) as UV-sunscreen compounds. These substances are typically extracted with a widely used standard protocol following quantification by various high performance liquid chromatography (HPLC) techniques. However, further preparation steps prior to HPLC analysis as well as different HPLC column types have not been systematically checked regarding separation quality and reproducibility. Therefore pure methanol, distilled water and HPLC eluent were evaluated as re-dissolution solvent for dried Prasiola and Porphyra extracts, which were subsequently analyzed on three reversed-phase C8 and C18 HPLC columns. The data indicate that distilled water and the HPLC eluent gave almost identical peak patterns and MAA contents on the C8 and C18 columns. In contrast, the application of the widely used methanol led to double peaks or even the loss of specific peaks as well as to a strong decline in total MAA amounts ranging from about 35% of the maximum in P. crispa to 80% of the maximum in P. umbilicalis. Consequently, methanol should be avoided as re-dissolution solvent for the HPLC sample preparation. An improved protocol for the MAA analysis in macroalgae in combination with a reliable C18 column is suggested.

  20. Information technology equipment cooling method

    DOEpatents

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  1. Analyses of procyanidins in foods using Diol phase HPLC

    USDA-ARS?s Scientific Manuscript database

    Separation of procyanidins using silica-based HPLC suffered from poor resolution for higher oligomers and low sensitivity due to the fluorescence quenching effects of methylene chloride in the mobile phase. Optimization of a published Diol-phase HPLC method resulted in near baseline separation for p...

  2. Assessing Jasminum grandiflorum L. authenticity by HPLC-DAD-ESI/MS(n) and effects on physiological enzymes and oxidative species.

    PubMed

    Ferreres, Federico; Grosso, Clara; Gil-Izquierdo, Angel; Valentão, Patrícia; Andrade, Paula B

    2014-01-01

    The dried flower buds of Jasminum grandiflorum L. are widely consumed as infusion and used in traditional medicine for psychiatric disorders. It is important to have a well-established method for the chemical characterization of J. grandiflorum since there are resemblances with a toxic species, Gelsemium sempervirens (L.) Jaume Saint-Hilaire. HPLC-DAD-ESI/MS(n) analysis allowed identifying six phenolic compounds for the first time. Moreover, the evaluation of in vitro activity against central nervous system (CNS) related enzymes was undertaken for the first time, as well as against reactive species in order to support the efficacy towards CNS disorders. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Development of a gas chromatography method for the determination of isotretinoin and its degradation products in pharmaceuticals.

    PubMed

    Lima, Eliana Martins; Diniz, Danielle G Almeida; Antoniosi-Filho, Nelson R

    2005-07-15

    This paper describes the development of a gas chromatography (GC) method used for the assay of isotretinoin in its isolated form and in pharmaceutical formulations. Isotretinoin soft and hard gelatin capsules were prepared with various excipients. The performance of the proposed gas chromatography method was compared to that of traditional high performance liquid chromatography (HPLC) systems for this substance, and the GC parameters were established based on several preliminary tests, including thermal analysis of isotretinoin. Results showed that gas chromatography-flame ionization detector (GC-FID) exhibited a separation efficiency superior to that of HPLC, particularly for separating isotretinoin degradation products. This method was proven to be effectively applicable to stability evaluation assays of isotretinoin and isotretinoin based pharmaceuticals.

  4. High performance liquid chromatographic hydrocarbon group-type analyses of mid-distillates employing fuel-derived fractions as standards

    NASA Technical Reports Server (NTRS)

    Seng, G. T.; Otterson, D. A.

    1983-01-01

    Two high performance liquid chromatographic (HPLC) methods have been developed for the determination of saturates, olefins and aromatics in petroleum and shale derived mid-distillate fuels. In one method the fuel to be analyzed is reacted with sulfuric acid, to remove a substantial portion of the aromatics, which provides a reacted fuel fraction for use in group type quantitation. The second involves the removal of a substantial portion of the saturates fraction from the HPLC system to permit the determination of olefin concentrations as low as 0.3 volume percent, and to improve the accuracy and precision of olefins determinations. Each method was evaluated using model compound mixtures and real fuel samples.

  5. Peroxyoxalate chemiluminescence detection of condensates of malondialdehyde with thiobarbituric acids using a flow system.

    PubMed

    Nakashima, K; Nagata, M; Takahashi, M; Akiyama, S

    1992-01-01

    The peroxyoxalate chemiluminescence(CL) detection method for the evaluation of the CL intensity of malondialdehyde(MDA) condensates with seven 2-thiobarbituric acid derivatives is described. The method consists of a flow injection technique together with a CL detection system using bis(2,4,6-trichlorophenyl) oxalate(TCPO) and hydrogen peroxide as chemiluminogenic reagents. Linear correlations between CL intensity and concentration are obtained for pmol levels of condensates. Among the condensates, 1,3-diethyl-2-thiobarbituric acid(DETBA)-MDA shows the largest CL intensity. High performance liquid chromatography (HPLC)/CL detection of DETBA-MDA and 1,3-diphenyl-2-thiobarbituric acid(DPTBA)-MDA using a mixture of TCPO and hydrogen peroxide in acetonitrile as a postcolumn reagent solution is also described. The detection limits for DETBA-MDA and DPTBA-MDA are 20 and 200 fmol, respectively, per 20 microL injection at a signal-to-noise ratio of 2. This HPLC/CL detection system was applied to the determination of MDA in rat brains by using DETBA as a fluorescent derivatizing reagent.

  6. 78 FR 64216 - Announcement of Requirements and Registration for “System for Locating People Using Electricity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ... for Locating People Using Electricity Dependent Medical Equipment During Public Health Emergencies... submissions to the ``System for Locating People Using Electricity Dependent Medical Equipment During Public....m. The ``System for Locating People Using Electricity Dependent Medical Equipment During Public...

  7. Automating the Air Force Retail-Level Equipment Management Process: An Application of Microcomputer-Based Information Systems Techniques

    DTIC Science & Technology

    1988-09-01

    could use the assistance of a microcomputer-based management information system . However, adequate system design and development requires an in-depth...understanding of the Equipment Management Section and the environment in which it functions were asked and answered. Then, a management information system was...designed, developed, and tested. The management information system is called the Equipment Management Information System (EMIS).

  8. 14 CFR 25.1445 - Equipment standards for the oxygen distributing system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Equipment standards for the oxygen... Miscellaneous Equipment § 25.1445 Equipment standards for the oxygen distributing system. (a) When oxygen is... crew on duty. (b) Portable walk-around oxygen units of the continuous flow, diluter-demand, and...

  9. 14 CFR 25.1445 - Equipment standards for the oxygen distributing system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Equipment standards for the oxygen... Miscellaneous Equipment § 25.1445 Equipment standards for the oxygen distributing system. (a) When oxygen is... crew on duty. (b) Portable walk-around oxygen units of the continuous flow, diluter-demand, and...

  10. 14 CFR 25.1445 - Equipment standards for the oxygen distributing system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Equipment standards for the oxygen... Miscellaneous Equipment § 25.1445 Equipment standards for the oxygen distributing system. (a) When oxygen is... crew on duty. (b) Portable walk-around oxygen units of the continuous flow, diluter-demand, and...

  11. 14 CFR 25.1445 - Equipment standards for the oxygen distributing system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Equipment standards for the oxygen... Miscellaneous Equipment § 25.1445 Equipment standards for the oxygen distributing system. (a) When oxygen is... crew on duty. (b) Portable walk-around oxygen units of the continuous flow, diluter-demand, and...

  12. 14 CFR 25.1445 - Equipment standards for the oxygen distributing system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Equipment standards for the oxygen... Miscellaneous Equipment § 25.1445 Equipment standards for the oxygen distributing system. (a) When oxygen is... crew on duty. (b) Portable walk-around oxygen units of the continuous flow, diluter-demand, and...

  13. The placement of equipment in the Space Station Freedom using constraint based reasoning

    NASA Technical Reports Server (NTRS)

    Tanner, Steve; Fennel, Randy

    1991-01-01

    This paper describes the Rack Equipment Placement and Optimization System. The primary objective of this system is to assist engineers with the placement of equipment into the racks of the modules of Space Station Freedom. It accomplishes this by showing a user where equipment placement is possible and by generating potential layouts. The system uses an explicit representation of integration constraints to search for potential solutions for individual rack equipment items. A simulated annealing process is being evaluated for total solution generation as well. Versions of this system are in use now and are assisting with the development of the Space Station Freedom at the Marshall Space Flight Center in Huntsville, Alabama.

  14. [Hospital clinical engineer orientation and function in the maintenance system of hospital medical equipment].

    PubMed

    Li, Bin; Zheng, Yunxin; He, Dehua; Jiang, Ruiyao; Chen, Ying; Jing, Wei

    2012-03-01

    The quantity of medical equipment in hospital rise quickly recent year. It provides the comprehensive support to the clinical service. The maintenance of medical equipment becomes more important than before. It is necessary to study on the orientation and function of clinical engineer in medical equipment maintenance system. Refer to three grade health care system, the community doctors which is called General practitioner, play an important role as the gatekeeper of health care system to triage and cost control. The paper suggests that hospital clinical engineer should play similar role as the gatekeeper of medical equipment maintenance system which composed by hospital clinical engineer, manufacture engineer and third party engineer. The hospital clinical engineer should be responsible of guard a pass of medical equipment maintenance quality and cost control. As the gatekeeper, hospital clinical engineer should take the responsibility of "General engineer" and pay more attention to safety and health of medical equipment. The responsibility description and future transition? development of clinical engineer as "General Engineer" is discussed. More attention should be recommended to the team building of hospital clinical engineer as "General Engineer".

  15. The Logistics Equipment Carbon Emission Monitoring System for a Green Logistics

    NASA Astrophysics Data System (ADS)

    Choi, Hyungrim; Park, Byoungkwon; Lee, Byungha; Park, Yongsung; Lee, Changsup; Ha, Jeongsoo

    Recently, due to the global enforcement of obligations to reduce green house gases and various environmental regulations, low carbon green growth strategies are required. Currently, in our country, environment friendly logistics activities are staying in the early stage compared to advanced countries because of our country's large energy consumption type industrial structures. As a measure to respond to the trend of the reinforcement of international environmental regulations in the sector of logistics, active green logistics systems should be established and to solve this problem, this study is intended to develop a monitoring system that can manage the carbon emission of logistics equipment(container truck, discharging equipment etc) in real time using a new technology named IP-RFID. The monitoring system developed in this study can actively manage the carbon emission of individual logistics equipment by attaching IP-Tags that can measure the carbon emission of individual logistics equipment in real time and transmit the information obtained from the measurement directly to users through IP communication. Since carbon emission can be managed by logistics equipment and drivers can check the carbon emission of equipment through this system, the carbon emission generated in the logistics sector may be reduced by using this system.

  16. New validated high-performance liquid chromatographic method for simultaneous analysis of ten flavonoid aglycones in plant extracts using a C18 fused-core column and acetonitrile-tetrahydrofuran gradient.

    PubMed

    Olszewska, Monika A

    2012-09-01

    An HPLC method of high resolution has been developed and validated for the simultaneous determination of ten prominent flavonoid aglycones in plant materials using a fused-core C18-silica column (Ascentis® Express, 4.6 mm × 150 mm, 2.7 μm). The separation was accomplished with an acetonitrile-tetrahydrofuran gradient elution at a flow rate of 1 mL/min and temperature of 30°C. UV spectrophotometric detection was employed at 370 nm for flavonols (quercetin [QU], myricetin [MY], isorhamnetin [IS], kaempferol [KA], sexangularetin [SX], and limocitrin [LM]) and 340 nm for flavones (apigenin [AP], acacetin [AC], chrysoeriol [CH], and luteolin [LU]). The high resolution of critical pairs QU/LU (10.50), QU/CH (3.40), AP/CH (2.51), SX/LM (2.30), and IS/KA (2.70) was achieved within 30.3 min. The observed column back pressure was less than 4300 psi, thus acceptable for conventional HPLC equipment. The method was sensitive enough having LODs of 0.115-0.525 ng and good linearity (r > 0.9999) over the test range. The precision values, expressed as RSD values, were <7.5%, and the accuracy was in the range of 95.3-100.2% for all analytes except MY (73.8%). The method was successfully employed for the determination of flavonoids in several medicinal plants, such as Ginkgo biloba, Betula pendula, and a variety of Sorbus species. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Infrastructure for deployment of power systems

    NASA Technical Reports Server (NTRS)

    Sprouse, Kenneth M.

    1991-01-01

    A preliminary effort in characterizing the types of stationary lunar power systems which may be considered for emplacement on the lunar surface from the proposed initial 100-kW unit in 2003 to later units ranging in power from 25 to 825 kW is presented. Associated with these power systems are their related infrastructure hardware including: (1) electrical cable, wiring, switchgear, and converters; (2) deployable radiator panels; (3) deployable photovoltaic (PV) panels; (4) heat transfer fluid piping and connection joints; (5) power system instrumentation and control equipment; and (6) interface hardware between lunar surface construction/maintenance equipment and power system. This report: (1) presents estimates of the mass and volumes associated with these power systems and their related infrastructure hardware; (2) provides task breakdown description for emplacing this equipment; (3) gives estimated heat, forces, torques, and alignment tolerances for equipment assembly; and (4) provides other important equipment/machinery requirements where applicable. Packaging options for this equipment will be discussed along with necessary site preparation requirements. Design and analysis issues associated with the final emplacement of this power system hardware are also described.

  18. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    USDA-ARS?s Scientific Manuscript database

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  19. Competitive Nitration of Benzene-Fluorobenzene and Benzene-Toluene Mixtures: Orientation and Reactivity Studies Using HPLC

    ERIC Educational Resources Information Center

    Blankespoor, Ronald L.; Hogendoorn, Stephanie; Pearson, Andrea

    2007-01-01

    The reactivity and orientation effects of a substituent are analyzed by using HPLC to determine the competitive nitration of the benzene-toluene and benzene-fluorobenzene mixtures. The results have shown that HPLC is an excellent instrumental method to use in analyzing these mixtures.

  20. Size exclusion HPLC of proteins for evaluation of durum wheat quality

    USDA-ARS?s Scientific Manuscript database

    The present research aimed to assess size exclusion HPLC (SE-HPLC) in protein molecular weight distribution determination for quality evaluation of durum semolina. Semolina samples were milled from 13 durum genotypes grown at 7 locations in 2009 and 2010 in ND. Sodium dodecyl sulfate (SDS) buffer ...

  1. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    ERIC Educational Resources Information Center

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  2. The equipment access software for a distributed UNIX-based accelerator control system

    NASA Astrophysics Data System (ADS)

    Trofimov, Nikolai; Zelepoukine, Serguei; Zharkov, Eugeny; Charrue, Pierre; Gareyte, Claire; Poirier, Hervé

    1994-12-01

    This paper presents a generic equipment access software package for a distributed control system using computers with UNIX or UNIX-like operating systems. The package consists of three main components, an application Equipment Access Library, Message Handler and Equipment Data Base. An application task, which may run in any computer in the network, sends requests to access equipment through Equipment Library calls. The basic request is in the form Equipment-Action-Data and is routed via a remote procedure call to the computer to which the given equipment is connected. In this computer the request is received by the Message Handler. According to the type of the equipment connection, the Message Handler either passes the request to the specific process software in the same computer or forwards it to a lower level network of equipment controllers using MIL1553B, GPIB, RS232 or BITBUS communication. The answer is then returned to the calling application. Descriptive information required for request routing and processing is stored in the real-time Equipment Data Base. The package has been written to be portable and is currently available on DEC Ultrix, LynxOS, HPUX, XENIX, OS-9 and Apollo domain.

  3. Transfusion associated peak in hb HPLC chromatogram - a case report.

    PubMed

    Jain, Sonal; Dass, Jasmita; Pati, Hara Prasad

    2012-01-01

    High performance liquid chromatography (HPLC) and electrophoresis are commonly used to diagnose various hemoglobinopathies. However, insufficient information about the transfusion history can lead to unexpected and confusing results. We are reporting a case of Juvenile myelomonocytic leukemia (JMML) in which HbHPLC was done to quantify fetal hemoglobin (HbF). The chromatogram showed elevated HbF along with a peak in the HbD window. A transfusion acquired peak was suspected based on the unexpectedly low percentage of HbD and was subsequently confirmed using parental HbHPLC.

  4. Transfusion Associated Peak in Hb HPLC Chromatogram – a Case Report

    PubMed Central

    Jain, Sonal; Dass, Jasmita; Pati, Hara Prasad

    2012-01-01

    High performance liquid chromatography (HPLC) and electrophoresis are commonly used to diagnose various hemoglobinopathies. However, insufficient information about the transfusion history can lead to unexpected and confusing results. We are reporting a case of Juvenile myelomonocytic leukemia (JMML) in which HbHPLC was done to quantify fetal hemoglobin (HbF). The chromatogram showed elevated HbF along with a peak in the HbD window. A transfusion acquired peak was suspected based on the unexpectedly low percentage of HbD and was subsequently confirmed using parental HbHPLC. PMID:22348188

  5. HPLC for quality control of polyimides

    NASA Technical Reports Server (NTRS)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  6. Detection of honey adulteration with starch syrup by high performance liquid chromatography.

    PubMed

    Wang, Shaoqing; Guo, Qilei; Wang, Linlin; Lin, Li; Shi, Hailiang; Cao, Hong; Cao, Baosen

    2015-04-01

    According to saccharide profile comparison between starch syrups and pure honeys analysed through high performance liquid chromatography (HPLC), a characteristic peak was found at 15.25 min retention time in HPLC chromatogram of syrup, but no peak was observed at the same retention time in chromatogram of pure honeys. This characteristic peak for syrup was identified as an overlapping peak of oligosaccharides with more than 5 degree of polymerisation (DP) based on HPLC chromatogram comparison between starch syrup and a series of standard mono-, di- and oligosaccharides of 3-7 DP. Additionally syrup content correlated linearly with the height of the characteristic peak of syrup under different slope in two ranges 2.5-7.5% and 10-100%, respectively. Therefore, the characteristic peak at 15.25 min retention time can serve as a syrup indicator in HPLC analysis of the adulterated honeys. This new HPLC method for honey adulteration detection was further applied in an authenticity inspection on more than 100 commercial honeys. In addition to the improved accuracy of honey adulteration detection, the proposed HPLC method was simple, low cost and easy practice for honey product quality control by government department considering the popularity of HPLC device and technology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Study of rat hypothalamic proteome by HPLC/ESI ion trap and HPLC/ESI-Q-TOF MS.

    PubMed

    Iqbal, Javed; Li, Wang; Ullah, Kaleem; Hasan, Murtaza; Linna, Guo; Awan, Umer; Zhang, Yongqian; Batool, Sajida; Qing, Hong; Deng, Yulin

    2013-08-01

    The proteomic profile of hypothalamus, a key organ of CNS, is explored here by employing two widely used MS techniques, i.e. HPLC/ESI-ion trap and HPLC/ESI-quadrupole-TOF MS. Strong cation exchange is used for the fractionation of peptides and protein search engine MASCOT is employed for data query. One hundred and thirty six proteins with 10 973 peptides were identified by HPLC/ESI-ion trap MS, while 140 proteins with 32 183 peptides were characterized by HPLC/ESI-quadrupole-TOF MS. Among the total 198 proteins identified in both experiments, 78 proteins were common in both sets of conditions. The rest of the 120 proteins were identified distinctly in both MS strategies, i.e. 58 unique proteins were found using the quadrupole-TOF while 62 were found with the HPLC/ESI-ion trap. Moreover, these proteins were classified into groups based on their functions performed in the body. Results presented here identified some important signal and cellular defense proteins inevitable for survival in stressed conditions. Additionally, it is also shown that any single MS strategy is not reliable for good results due to loss of data depending on sensitivity of the instrument used. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Kinetic performance of narrow-bore columns on a micro-system for high performance liquid chromatography.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2012-05-04

    The kinetic performance of 0.5 mm × 50 mm columns packed with 2.7 μm Halo-C(18) core-shell particles and 3 μm EP-120-C(18) fully porous particles fitted on an Eksigent LC-Express Ultra μHPLC system were measured. The instrument contribution to band broadening was obtained by directly connecting the injection valve and the detector cell with a short, narrow PEEKSIL tube. The connections between the column and the connecting tubes, the column endfittings and its frits contribute to band spreading and are responsible for a significant rear peak tailing, even for retained compounds, resulting in a significant loss of efficiency. Our results show that the μHPLC system could outperform the current VHPLC systems using 2.1mm I.D. columns packed with 1.7 μm particles if it were using 0.5mm I.D. columns packed with 1 μm particles, if it could operate at a few kbar pressure drop, and if the sum of the contributions of the instrument, column endfittings and the column frits to band dispersion were three times smaller than it is at present. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Automated dispersive liquid-liquid microextraction coupled to high performance liquid chromatography - cold vapour atomic fluorescence spectroscopy for the determination of mercury species in natural water samples.

    PubMed

    Liu, Yao-Min; Zhang, Feng-Ping; Jiao, Bao-Yu; Rao, Jin-Yu; Leng, Geng

    2017-04-14

    An automated, home-constructed, and low cost dispersive liquid-liquid microextraction (DLLME) device that directly coupled to a high performance liquid chromatography (HPLC) - cold vapour atomic fluorescence spectroscopy (CVAFS) system was designed and developed for the determination of trace concentrations of methylmercury (MeHg + ), ethylmercury (EtHg + ) and inorganic mercury (Hg 2+ ) in natural waters. With a simple, miniaturized and efficient automated DLLME system, nanogram amounts of these mercury species were extracted from natural water samples and injected into a hyphenated HPLC-CVAFS for quantification. The complete analytical procedure, including chelation, extraction, phase separation, collection and injection of the extracts, as well as HPLC-CVAFS quantification, was automated. Key parameters, such as the type and volume of the chelation, extraction and dispersive solvent, aspiration speed, sample pH, salt effect and matrix effect, were thoroughly investigated. Under the optimum conditions, linear range was 10-1200ngL -1 for EtHg + and 5-450ngL -1 for MeHg + and Hg 2+ . Limits of detection were 3.0ngL -1 for EtHg + and 1.5ngL -1 for MeHg + and Hg 2+ . Reproducibility and recoveries were assessed by spiking three natural water samples with different Hg concentrations, giving recoveries from 88.4-96.1%, and relative standard deviations <5.1%. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Rapid method for monitoring N-nitrosodimethylamine in drinking water at the ng/L level without pre-concentration using high-performance liquid chromatography-chemiluminescence detection.

    PubMed

    Kodamatani, Hitoshi; Yamasaki, Hitomi; Sakaguchi, Takeru; Itoh, Shinya; Iwaya, Yoshimi; Saga, Makoto; Saito, Keiitsu; Kanzaki, Ryo; Tomiyasu, Takashi

    2016-08-19

    As a contaminant in drinking water, N-nitrosodimethylamine (NDMA) is of great concern because of its carcinogenicity; it has been limited to levels of ng/L by regulatory bodies worldwide. Consequently, a rapid and sensitive method for monitoring NDMA in drinking water is urgently required. In this study, we report an improvement of our previously proposed HPLC-based system for NDMA determination. The approach consists of the HPLC separation of NDMA, followed by NDMA photolysis to form peroxynitrite and detection with a luminol chemiluminescence reaction. The detection limit for the improved HPLC method was 0.2ng/L, which is 10 times more sensitive than our previously reported system. For tap water measurements, only the addition of an ascorbic acid solution to eliminate residual chlorine and passage through an Oasis MAX solid-phase extraction cartridge are needed. The proposed NDMA determination method requires a sample volume of less than 2mL and a complete analysis time of less than 15min per sample. The method was utilized for the long-term monitoring of NDMA in tap water. The NDMA level measured in the municipal water survey was 4.9ng/L, and a seasonal change of the NDMA concentration in tap water was confirmed. The proposed method should constitute a useful NDMA monitoring method for protecting drinking water quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system.

    PubMed

    Ford, Michael J; Deibel, Michael A; Tomkins, Bruce A; Van Berkel, Gary J

    2005-07-15

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mum/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 muL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by approximately 8% or more) than the literature values.

  12. Chiral ligand exchange high-speed countercurrent chromatography: mechanism, application and comparison with conventional liquid chromatography in enantioseparation of aromatic α-hydroxyl acids

    PubMed Central

    Tong, Shengqiang; Shen, Mangmang; Cheng, Dongping; Ito, Yoichiro; Yan, Jizhong

    2014-01-01

    This work concentrates on the separation mechanism and application of chiral ligand exchange high-speed countercurrent chromatography (HSCCC) in enantioseparations, and comparison with traditional chiral ligand exchange high performance liquid chromatography (HPLC). The enantioseparation of ten aromatic α-hydroxyl acids were performed by these two chromatographic methods. Results showed that five of the racemates were successfully enantioseparated by HSCCC while only three of the racemates could be enantioseparated by HPLC using a suitable chiral ligand mobile phase additive. For HSCCC, the two-phase solvent system was composed of butanol-water (1:1, v/v), to which N-n-dodecyl-L-proline was added in the organic phase as chiral ligand and cupric acetate was added in the aqueous phase as a transition metal ion. Various operation parameters in HSCCC were optimized by enantioselective liquid-liquid extraction. Based on the results of the present studies the separation mechanism for HSCCC was proposed. For HPLC, the optimized mobile phase composed of aqueous solution containing 6 mmol L−1 L-phenylalanine and 3 mmol L−1 cupric sulfate and methanol was used for enantioseparation. Among three ligands tested on a conventional reverse stationary phase column, only one was found to be effective. In the present studies HSCCC presented unique advantages due to its high versatility of two-phase solvent systems and it could be used as an alternative method for enantioseparations. PMID:25087742

  13. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methodsmore » determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.« less

  14. Preparative enantiomer separation of dichlorprop with a cinchona-derived chiral selector employing centrifugal partition chromatography and high-performance liquid chromatography: a comparative study.

    PubMed

    Gavioli, Elena; Maier, Norbert M; Minguillón, Cristina; Lindner, Wolfgang

    2004-10-01

    A countercurrent chromatography protocol for support-free preparative enantiomer separation of the herbicidal agent 2-(2,4-dichlorphenoxy)propionic acid (dichlorprop) was developed utilizing a purposefully designed, highly enantioselective chiral stationary-phase additive (CSPA) derived from bis-1,4-(dihydroquinidinyl)phthalazine. Guided by liquid-liquid extraction experiments, a solvent system consisting of 10 mM CSPA in methyl tert-butyl ether and 100 mM sodium phosphate buffer (pH 8.0) was identified as a suitable stationary/mobile-phase combination. This solvent system provided an ideal compromise among stationary-phase retention, enantioselectivity, and well-balanced analyte distribution behavior. Using a commercial centrifugal partition chromatography instrument, complete enantiomer separations of up to 366 mg of racemic dichlorprop could be achieved, corresponding to a sample load being equivalent to the molar amount of CSPA employed. Comparison of the preparative performance characteristics of the CPC protocol with that of a HPLC separation using a silica-supported bis-1,4-(dihydroquinidinyl)phthalazine chiral stationary phase CSP revealed comparable loading capacities for both techniques but a significantly lower solvent consumption for CPC. With respect to productivity, HPLC was found to be superior, mainly due to inherent flow rate restrictions of the CPC instrument. Given that further progress in instrumental design and engineering of dedicated, highly enantioselective CSPAs can be achieved, CPC may offer a viable alternative to CSP-based HPLC for preparative-scale enantiomer separation.

  15. 49 CFR 232.613 - End-of-train devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR FREIGHT AND OTHER NON-PASSENGER TRAINS AND EQUIPMENT; END-OF-TRAIN DEVICES Electronically Controlled Pneumatic (ECP) Braking Systems § 232.613 End-of... equipped with an ECP brake system unless that train is equipped with a functioning ECP-EOT device designed...

  16. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  17. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  18. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  19. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  20. Research on large equipment maintenance system in life cycle

    NASA Astrophysics Data System (ADS)

    Xu, Xiaowei; Wang, Hongxia; Liu, Zhenxing; Zhang, Nan

    2017-06-01

    In order to change the current disadvantages of traditional large equipment maintenance concept, this article plans to apply the technical method of prognostics and health management to optimize equipment maintenance strategy and develop large equipment maintenance system. Combined with the maintenance procedures of various phases in life cycle, it concluded the formulation methods of maintenance program and implement plans of maintenance work. In the meantime, it takes account into the example of the dredger power system of the Waterway Bureau to establish the auxiliary platform of ship maintenance system in life cycle.

  1. The automatic control system and stand-by facilities of the TDMA-40 equipment

    NASA Astrophysics Data System (ADS)

    Gudenko, D. V.; Pankov, G. Kh.; Pauk, A. G.; Tsirlin, V. M.

    1980-10-01

    When a controlling station in a satellite communications system is out of order, a complex algorithm must be carried out for automatic operation of the stand-by equipment. A processor has been developed to perform this algorithm, as well as operations involving the stand-by facilities of the receiving-transmitting equipment of the station. The design principles and solutions to problems in developing the equipment for the monitoring and controlling systems are described. These systems are based on multistation access using time division multiplexing. Algorithms are presented for the operation of the synchronizing processor and the control processor of the equipment. The automatic control system and stand-by facilities make it possible to reduce the service personnel and to design an unattended station.

  2. Using web technique in the managing regulatory requirements of medical equipment for the nursing department.

    PubMed

    Chien, Chia-Hung; Hwang, Bao-Hwa; Lin, Thuey-Ru; Wang, Cheng-Yi; Chong, Fok-Ching

    2006-01-01

    The centralized and information management are in common use technique of modern management. The management of the medical equipment emphasized in the purchase and the maintenance management in early days,and cost down now is import factor for medical equipment management because the health insurance system causes the hospital budget reduced, so in the cost down strategy is to reduce the amount of money and promoting the efficient of use . Another important subject in medical equipment management is patient safety, so how to ensuring the quality of medical equipment is also having to notice. In the paper, we will provide an architecture for assistant the nursing department to develop a information system on the centralized and information management of valuable medical equipment. Through the system operation we hope can promote the effect and the quality of the medical equipment usage. This system implement up to now has more than half a year, and could acquired some concrete result: the utilization rate promotes doubly, the rate of breaking downs, the borrowed time cuts 75%, the cost downs for equipment purchase and satisfaction increases for user. In this paper, in addition to explaining the above-mentioned result,also discusses the design principle and structure on the whole system. We hope the protocol could be used as for clinical unit to control their valuable equipments and match the authority expectation.

  3. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  4. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  5. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  6. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  7. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  8. ISAARE: Information System for Adaptive, Assistive, and Recreational Equipment: Volume I: Existence; Volume II, Communication; Volume V, Adaptation.

    ERIC Educational Resources Information Center

    Melichar, Joseph F.

    Described as part of the Information System for Adaptive, Assistive and Recreational Equipment are equipment items for physically handicapped pupils in the functional areas of existence, equipment and adaptation. Reviewed in the existence section are such items as assistive food containers and container stabilizers, feeder accessories, bowel and…

  9. 14 CFR 25.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical equipment and installations. 25... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Electrical Systems and Equipment § 25.1353 Electrical equipment and installations. (a) Electrical equipment and controls must be...

  10. 14 CFR 25.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical equipment and installations. 25... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Electrical Systems and Equipment § 25.1353 Electrical equipment and installations. (a) Electrical equipment and controls must be...

  11. 14 CFR 25.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical equipment and installations. 25... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Electrical Systems and Equipment § 25.1353 Electrical equipment and installations. (a) Electrical equipment and controls must be...

  12. 14 CFR 29.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical equipment and installations. 29... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 29.1353 Electrical equipment and installations. (a) Electrical equipment, controls, and wiring...

  13. 14 CFR 29.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical equipment and installations. 29... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 29.1353 Electrical equipment and installations. (a) Electrical equipment, controls, and wiring...

  14. 14 CFR 25.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical equipment and installations. 25... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Electrical Systems and Equipment § 25.1353 Electrical equipment and installations. (a) Electrical equipment and controls must be...

  15. 14 CFR 29.1353 - Electrical equipment and installations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical equipment and installations. 29... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 29.1353 Electrical equipment and installations. (a) Electrical equipment, controls, and wiring...

  16. Simultaneous separation and determination of 15 organic UV filters in sunscreen cosmetics by HPLC-ESI-MS/MS.

    PubMed

    Meng, X; Ma, Q; Bai, H; Wang, Z; Han, C; Wang, C

    2017-08-01

    A comprehensive methodology for the simultaneous determination of 15 multiclass organic UV filters in sunscreen cosmetics was developed using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Sunscreen cosmetics of various matrices, such as toning lotion, emulsion, cream and lipstick, were analysed. Ultrasound-assisted extraction (UAE) was utilized as the extraction technique for sample preparation. The 15 UV filters were chromatographically separated by two groups of mobile phase system on an XBridge C 18 analytical column (150 × 2.1 mm I.D., 3.5 μm particle size) and quantified using HPLC-ESI-MS/MS. The quantitation was performed using the external calibration method. The established method was validated in terms of linearity, sensitivity, specificity, accuracy, stability, intraday and interday precisions, recovery and matrix effect. The method was also applied for the determination of UV filters in commercial sunscreen cosmetics. The experimental results demonstrated that the developed method was accurate, rapid and sensitive and can be used for the analytical control of sunscreen cosmetics. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  17. Determination of etoxazole residues in fruits and vegetables by SPE clean-up and HPLC-DAD.

    PubMed

    Malhat, Farag; Badawy, Hany; Barakat, Dalia; Saber, Ayman

    2013-01-01

    A method for determination of etoxazole residues in apples, strawberries and green beans was developed and validated. The analyte was extracted with acetonitrile from foodstuff and a charcoal-celite cartridge was used for clean-up of raw extracts. Reversed phase high performance liquid chromatography with photodiode array detector (HPLC-DAD) was used for the determination and quantification of etoxazole residues in the studied samples. The calibration graphs of etoxazole in a solvent or three blank matrixes were linear within the tested intervals 0.01-2 mg L(-1), with correlation coefficient of determination >0.999. The combined solid phase extraction (SPE) clean-up and the chromatographic method steps were sensitive and reliable for simultaneous determination of etoxazole residues in the studied samples. The average recoveries of etoxazole in the tested foodstuffs were between 93.4 to 102% at spiking levels of 0.01, 0.10, and 0.50 mg kg(-1), with relative standard deviations ranging from 2.8 to 4.7%, in agreement with directives for method validation in residue analyses. The limit of detection (LOD) of the HPLC-DAD system was 100 pg. The limit of quantification of the entire method was 0.01 mg kg(-1).

  18. Quantitative Determination of α-Arbutin, β-Arbutin, Kojic Acid, Nicotinamide, Hydroquinone, Resorcinol, 4-Methoxyphenol, 4-Ethoxyphenol, and Ascorbic Acid from Skin Whitening Products by HPLC-UV.

    PubMed

    Wang, Yan-Hong; Avonto, Cristina; Avula, Bharathi; Wang, Mei; Rua, Diego; Khan, Ikhlas A

    2015-01-01

    An HPLC-UV method was developed for the quantitative analysis of nine skin whitening agents in a single injection. These compounds are α-arbutin, β-arbutin, kojic acid, nicotinamide, resorcinol, ascorbic acid, hydroquinone, 4-methoxyphenol, and 4-ethoxyphenol. The separation was achieved on a reversed-phase C18 column within 30 min. The mobile phase was composed of water and methanol, both containing 0.1% acetic acid (v/v). The stability of the analytes was evaluated at different pH values between 2.3 and 7.6, and the extraction procedure was validated for different types of skin whitening product matrixes, which included two creams, a soap bar, and a capsule. The best solvent system for sample preparation was 20 mM NaH2PO4 containing 10% methanol at pH 2.3. The analytical method was validated for accuracy, precision, LOD, and LOQ. The developed HPLC-UV method was applied for the quantitation of the nine analytes in 59 skin whitening products including creams, lotions, sera, foams, gels, mask sheets, soap bars, tablets, and capsules.

  19. High-performance liquid chromatography of quinoidal imminium compounds derived from triphenylmethanes

    USGS Publications Warehouse

    Abidi, S.L.

    1983-01-01

    A series of eleven p-aminotriphenylmethane dyes have been studied by high-performance liquid chromatography (HPLC). The combined use of HPLC and spectrophotometry permits specific detection of these compounds in the visible range around 600 nm. As the high affinity of the imminium cations for the active sites of the hydrocarbonaceous stationary phase has presented difficulties for reversed-phase HPLC with pure solvents, organic electrolytes were added to the mobile phase to facilitate the elution of the components with improved selectivity, sensitivity (minimum detection limit, 0.1 μg/ml), and peak symmetry. The effects of chromatographic variables on the component retentivity were investigated. Retention times of the dye analytes decreased with increasing concentration of the added ionic reagent and with decreasing number of the hydrophobic alkyl substituents on the nitrogen atom. The influence of pH on the retention parameters appears to parallel that observed previously for cationic quaternary ammonium compounds. Among the acidic reagents employed, naphthalenesulfonic acid yielded the most satisfactory results. The use of binary electrolyte systems invariably improved the chromatographic behavior of the imminium solutes analyzed. Results obtained with two different octadecylsilica columns have been compared.

  20. Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulations.

    PubMed

    Mukherjee, Jayanti; Das, Ayan; Chakrabarty, Uday Sankar; Sahoo, Bijay Kumar; Dey, Goutam; Choudhury, Hira; Pal, Tapan Kumar

    2011-01-01

    This study describes development and subsequent validation of a reversed phase high performance liquid chromatographic (RP-HPLC) method for the estimation of nandrolone phenylpropionate, an anabolic steroid, in bulk drug, in conventional parenteral dosage formulation and in prepared nanoparticle dosage form. The chromatographic system consisted of a Luna Phenomenex, CN (250 mm x 4.6 mm, 5 microm) column, an isocratic mobile phase comprising 10 mM phosphate buffer and acetonitrile (50:50, v/v) and UV detection at 240 nm. Nandrolone phenylpropionate was eluted about 6.3 min with no interfering peaks of excipients used for the preparation of dosage forms. The method was linear over the range from 0.050 to 25 microg/mL in raw drug (r2 = 0.9994). The intra-day and inter-day precision values were in the range of 0.219-0.609% and 0.441-0.875%, respectively. Limits of detection and quantitation were 0.010 microg/mL and 0.050 microg/mL, respectively. The results were validated according to International Conference on Harmonization (ICH) guidelines in parenteral and prepared nanoparticle formulation. The validated HPLC method is simple, sensitive, precise, accurate and reproducible.

Top